{"manifest":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000JVYZD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPESD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a56595a44","Version":"HPD4"},{"DeviceName":"MB4000JVYZC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPESD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a56595a43","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB6000JVYZD and MB4000JVYZC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB6000JVYZD and MB4000JVYZC Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:&nbsp;</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3704312","datemodified":"2021-07-25T15:54:09","file_list":["cp048617.xml","cpqsetup.exe","payload.json","setup.dll","SMBPESD4.rel"],"md5sum":"43b5ea2fad33452a7c9e8b7d879aa7ad","name":"cp048617.exe","release":"2021-07-25T15:47:08","revision":"0","sha1sum":"d3606b852c1697153004de6f378beb5b7b734f15","size":"3MB","target_guids":["002340a5-4d00-3642-3030-304a56595a44","002340a5-4d00-3442-3030-304a56595a43"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"29d3ee50608a4989be087dbfc8603ca4","version":"18fef078fcea4023bbe0f5929a33498c"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB6000JVYZD and MB4000JVYZC Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB6000JVYZDおよびMB4000JVYZCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB4000JVYZC","target_guid":"002340a5-4d00-3442-3030-304a56595a43","type":"sas"},{"id":"MB6000JVYZD","target_guid":"002340a5-4d00-3642-3030-304a56595a44","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T12:19:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JVYZC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB6000JVYZD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5979952","datemodified":"2021-05-17T21:19:48","file_list":["I36_2.90_04_29_2021.signed.flash","SignedImageInstaller64.dll","cp047765.xml","cpqsetup.exe","cpqsysio64.sys"],"md5sum":"da4dab30fe42693cedc226f45e3b95b3","name":"cp047765.exe","release":"2021-05-17T21:03:15","revision":"0","sha1sum":"8e19001b75eb6032c2dc8ced65a3d8689f0a1e52","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021"}],"id":{"product":"05ff557836a74529980644359cf7e2c2","version":"8e05119d8a964a7aadfe681483d22bd8"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.<br />\n&nbsp;</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br />\n </p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant BL460c Gen9/WS460c Gen9 (I36) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant BL460c Gen9/WS460c Gen9 (I36)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"1","name":"Microsoft Windows 7 (64-bit) - All Editions","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows 8.1 (64-bit)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-29T15:35:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","latest_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358.  These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390.  These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"I36","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"Supplemental Update / Online ROM Flash Smart Component which upgrades the switch firmware on the HPE Express Bay Enablement Switch Card"},{"lang":"cn","x_late":"可更新 HPE Express 托架支持交换卡上的交换机固件的补充更新/在线 ROM 刷新组件"},{"lang":"tw","x_late":"可升級 HPE Express 插槽啟用交換器卡的交換器韌體的補充更新/線上 ROM 更新智慧型元件"},{"lang":"ko","x_late":"HPE Express Bay Enablement Switch Card에서 스위치 펌웨어를 업그레이드하는 추가 업데이트/온라인 ROM 플래시 스마트 구성요소"},{"lang":"ja","x_late":"HPE Express Bay Enablement Switchカード上のスイッチファームウェアをアップグレードするサプリメンタルアップデート/オンラインROMフラッシュコンポーネント"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Supplemental Update / Online ROM Flash Component for Linux (x64) &ndash; HPE Express Bay Enablement Switch Card<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.78(B)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 1.78<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.78<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for SUSE Linux Enterprise Server 15 OS</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"790499","datemodified":"2018-09-27T22:37:47","file_list":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-94189dca85-1.78-2.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-94189dca85-1.78-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-94189dca85-1.78-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-94189dca85-1.78-2.1/CP034965.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-94189dca85-1.78-2.1/Config.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-94189dca85-1.78-2.1/flash","./usr/lib/x86_64-linux-gnu/firmware-smartarray-94189dca85-1.78-2.1/hdr_Pedali_Rev_0x02_Btlg_0x00.bin","./usr/lib/x86_64-linux-gnu/firmware-smartarray-94189dca85-1.78-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-94189dca85-1.78-2.1/pedale-VP3-20171113-1.78-release.rbf","./usr/lib/x86_64-linux-gnu/firmware-smartarray-94189dca85-1.78-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP034965.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP034965.scexe"],"md5sum":"f4680b1dc270a860222aaabb9f0279d1","name":"firmware-smartarray-94189dca85-1.78-2.1.x86_64.rpm","release":"2018-09-28T03:35:03","revision":"0","sha1sum":"324898c33c640f791403632934f9203488a094d9","size":"771KB","target_guids":[],"type_of_change":"0","version":"1.78"}],"id":{"product":"25be2dadb23b40e0941b154b3b7febfe","version":"977a33d8eb4c4df4a8cfd6236507c0ba"},"installation":{"command":"CP034965.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><u>Power cycle / cold reboot is required after installation for updates to take effect.</u></p>\n\n<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:40px\"><strong><em>Updating firmware with rpm installed:</em></strong></p>\n\n<ul style=\"margin-left:40px\">\n\t<li>Install the firmware rpm using the command:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li>\n\t<li>The CP034965.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-94189dca85-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above&nbsp;</li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./ CP034965.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-94189dca85-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p style=\"margin-left:40px\"><strong><em>Updating firmware without installing the rpm:</em></strong></p>\n\n<ul style=\"margin-left:40px\">\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-94189dca85-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-94189dca85-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p style=\"margin-left:40px\"><strong><em>Additional Information:</em></strong></p>\n\n<p style=\"margin-left:40px\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant</u></a>&nbsp;on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li>\n\t<li>Run launch_sum.sh script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Supplemental Update / Online ROM Flash Component for Linux (x64) – HPE Express Bay Enablement Switch Card"},{"lang":"cn","x_late":"Linux (x64)版补充更新/在线ROM刷新组件 - HPE Express托架支持交换卡"},{"lang":"tw","x_late":"適用於 Linux (x64) 的補充更新/線上 ROM 更新元件 – HPE Express 插槽啟用交換器卡"},{"lang":"ko","x_late":"Linux(x64)용 추가 업데이트/온라인 ROM 플래시 구성요소 - HPE Express Bay Enablement Switch Card"},{"lang":"ja","x_late":"サプリメンタルアップデート/オンラインROMフラッシュコンポーネント for Linux (x64) - HPE Express Bay Enablement Switch Card"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_operating_systems":[{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2018-03-15T06:48:46","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Corrected the&nbsp;temperature status of Seagate NVMe hard drives.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for SUSE Linux Enterprise Server 15 OS</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"}],"sw_keys":[{"name":"HP Gen9 ExpressBay 6SFF Drive Cage","sw_key_expectedpath":"firmware:sd:switchbackplane"},{"name":"HP G9 Express Bay 6 SFF Drive Cage","sw_key_expectedpath":"firmware:sd:switchbackplane"},{"name":"HP Gen9 ExpressBay 5SFF Drive Cage","sw_key_expectedpath":"firmware:sd:switchbackplane"},{"name":"HP G9 Express Bay 5 SFF Drive Cage","sw_key_expectedpath":"firmware:sd:switchbackplane"},{"name":"DL360p Gen9 2SFF ExpressBay Bkpln","sw_key_expectedpath":"firmware:sd:switchbackplane"},{"name":"DL360 Gen9 8SFF 4PCIe+4SAS Bkpln","sw_key_expectedpath":"firmware:sd:switchbackplane"},{"name":"HP Express Bay 6 HDD Switch Card","sw_key_expectedpath":"firmware:sd:switchbackplane"},{"name":"HP DL360G9 2 SFF Express Bay Drive Cage","sw_key_expectedpath":"firmware:sd:switchbackplane"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"tw","x_late":"此元件可更新 ProLiant Gen9 NVMe 儲存背板上的韌體。"},{"lang":"en","x_late":"This component updates the firmware on ProLiant Gen9 NVMe storage backplanes."},{"lang":"ko","x_late":"이 구성 요소는 ProLiant Gen9 NVMe 스토리지 백플레인에서 펌웨어를 업데이트합니다."},{"lang":"cn","x_late":"该组件可更新 ProLiant Gen9 NVMe 存储背板上的固件。"},{"lang":"ja","x_late":"このコンポーネントは、ProLiant Gen9 NVMe ストレージバックプレーンをアップデートします。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"410377","datemodified":"2018-10-03T00:03:54","file_list":["./usr/lib/i386-linux-gnu/firmware-nvmebackplane-8.4-4.1","./usr/lib/i386-linux-gnu/firmware-nvmebackplane-8.4-4.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-nvmebackplane-8.4-4.1/.setup","./usr/lib/i386-linux-gnu/firmware-nvmebackplane-8.4-4.1/CP034973.xml","./usr/lib/i386-linux-gnu/firmware-nvmebackplane-8.4-4.1/NVMe_BP_flashV8B4_signed.hex","./usr/lib/i386-linux-gnu/firmware-nvmebackplane-8.4-4.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-nvmebackplane-8.4-4.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP034973.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP034973.scexe"],"md5sum":"a3447375df9de5db8adb2f006b8883e3","name":"firmware-nvmebackplane-8.4-4.1.i386.rpm","release":"2018-10-03T05:03:03","revision":"0","sha1sum":"2b62a77cdc4235f4498672d0584c099cdb207168","size":"400KB","target_guids":[],"type_of_change":"0","version":"8.4"}],"id":{"product":"591f92a69b8e4f239251cc96e1b31290","version":"8ff6481f2f5e4e97804bc6514d03a4ab"},"installation":{"command":"cpqsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><em><strong>Updating firmware with rpm installed:</strong></em></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp; rpm -ivh &lt;rpm_filename&gt;.&nbsp; This extracts the contents of the rpm to the &#39;/usr/lib/i386-linux-gnu&#39; location</li>\n\t<li>The CP034973.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-nvmepic-gen9-*&#39; folder is based on the version of the rpm installed in the first step above</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./ CP034973.scexe in the &#39;/usr/lib/i386-linux-gnu/scexe-compat&#39; location (OR)</p>\n\n<p style=\"margin-left:40px\">&nbsp; &nbsp;&nbsp; # ./setup in the &#39;/usr/lib/i386-linux-gnu/firmware-nvmepic-gen9-*&#39; location</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: rpm -e &lt;rpm_package_name&gt;, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><em><strong>Updating firmware without installing the rpm:</strong></em></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the &#39;usr/lib/i386-linux-gnu/firmware-nvmepic-gen9-*&#39; location and run ./setup to update the firmware. The actual name of the &#39;firmware-nvmepic-gen9-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><em><strong>Additional Information:</strong></em></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp; It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\"><u>Service Pack for ProLiant&nbsp;</u></a>on a USB key using the&nbsp;<a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory,&nbsp;/SPP20xxxxx/packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow HP Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li>\n\t<li>Run launch_sum.sh script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Linux 的線上更新元件 - NVMe 背板 PIC 韌體"},{"lang":"en","x_late":"Online Flash Component for Linux - NVMe Backplane PIC Firmware"},{"lang":"ko","x_late":"Linux용 온라인 ROM 플래시 구성 요소 - NVMe 백플레인 PIC 펌웨어"},{"lang":"cn","x_late":"Linux版在线刷新组件 - NVMe背板PIC固件"},{"lang":"ja","x_late":"Linux用オンラインフラッシュコンポーネント - NVMeバックプレーンPICファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"id":"NVMe Backplane","target_guid":"","type":"pic"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2018-03-15T08:46:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Updated to support Service Pack for ProLiant version 2017.07.0</li>\n</ul>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;<strong>Note:</strong> If&nbsp;version 8.4 was previously installed, then it is not necessary to upgrade to version 8.4 (C).</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for SUSE Linux Enterprise Server 15 OS</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"}],"sw_keys":[{"name":"NVMePIC-Gen9","sw_key_expectedpath":"firmware:sd:nvmebackplane"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWCPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTED9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57435048","Version":"HPD9"},{"DeviceName":"EH000600JWCPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTED9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57435046","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EH000600JWCPF and EH000900JWCPH"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：EH000600JWCPFおよびEH000900JWCPH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - EH000600JWCPF and EH000900JWCPH Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3873520","datemodified":"2021-07-24T05:56:03","file_list":["cp048516.xml","cpqsetup.exe","payload.json","setup.dll","SKESTED9.rel"],"md5sum":"0c3a45301bdf6a9d9f8e3017fb46b088","name":"cp048516.exe","release":"2021-07-24T05:48:05","revision":"0","sha1sum":"0e6919eb3210071100cb8df2bfa76bcc085e32dc","size":"3MB","target_guids":["452340a5-3048-3030-3930-304a57435048","452340a5-3048-3030-3630-304a57435046"],"type_of_change":"1","version":"HPD9"}],"id":{"product":"308794285e444711a0eb3833d54eb10e","version":"9b6a6a135c584e569a44a8007308be33"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EH000600JWCPF and EH000900JWCPH Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EH000600JWCPFおよびEH000900JWCPHドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EH000600JWCPF","target_guid":"452340a5-3048-3030-3630-304a57435046","type":"sas"},{"id":"EH000900JWCPH","target_guid":"452340a5-3048-3030-3930-304a57435048","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T09:51:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH000900JWCPH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000600JWCPF","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000JEXYA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRESD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a45585941","Version":"HPD9"},{"DeviceName":"MB6000JEXYB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRESD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a45585942","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB4000JEXYA and MB6000JEXYB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB4000JEXYA and MB6000JEXYB Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD8</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3028648","datemodified":"2021-07-25T15:09:14","file_list":["cp048609.xml","cpqsetup.exe","payload.json","setup.dll","TTMRESD9.REL"],"md5sum":"2bfa591801d762dcd0acb7bac6b7bb83","name":"cp048609.exe","release":"2021-07-25T15:02:07","revision":"0","sha1sum":"64a550a4ae85c2b34726afc66bdf043d8d5da75f","size":"2MB","target_guids":["002340a5-4d00-3442-3030-304a45585941","002340a5-4d00-3642-3030-304a45585942"],"type_of_change":"1","version":"HPD9"}],"id":{"product":"705c5706f7b64a23bc5fcf7fbd4a5be7","version":"dd88875ae72949c6b4dfd68c6365be93"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB4000JEXYA and MB6000JEXYB Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB4000JEXYAおよびMB6000JEXYBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB4000JEXYA","target_guid":"002340a5-4d00-3442-3030-304a45585941","type":"sas"},{"id":"MB6000JEXYB","target_guid":"002340a5-4d00-3642-3030-304a45585942","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T11:13:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000JEXYB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB4000JEXYA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、HP Smart Update Manager(SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションから遠隔地にあるサーバーのファームウェアを更新することを可能にします。 このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5575640","datemodified":"2019-01-22T15:53:42","file_list":["./usr/lib/i386-linux-gnu/firmware-system-u24-1.60_2018_01_22-2.1","./usr/lib/i386-linux-gnu/firmware-system-u24-1.60_2018_01_22-2.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-system-u24-1.60_2018_01_22-2.1/.setup","./usr/lib/i386-linux-gnu/firmware-system-u24-1.60_2018_01_22-2.1/CP038805.xml","./usr/lib/i386-linux-gnu/firmware-system-u24-1.60_2018_01_22-2.1/U24_1.60_01_22_2018.signed.flash","./usr/lib/i386-linux-gnu/firmware-system-u24-1.60_2018_01_22-2.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-system-u24-1.60_2018_01_22-2.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP038805.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP038805.scexe"],"md5sum":"9f4b55abf38b05b8f3c035f38d9d6ae7","name":"firmware-system-u24-1.60_2018_01_22-2.1.i386.rpm","release":"2019-01-22T21:52:01","revision":"0","sha1sum":"094b7fc7276d268cd68a1d13e589e09e1e826587","size":"5MB","target_guids":[],"type_of_change":"2","version":"1.60_01-22-2018"}],"id":{"product":"195ed5d18cb04288998708cea17b124d","version":"1de8a7dd85014090b70a94394a614cc4"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HPE ProLiant Agentless Management Service (<strong>AMS</strong>) and HPE SNMP Agents (<strong>SNMP Agents</strong>) are both running.&nbsp; HPE does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager 8.0.0 or later, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、iLOとの通信ができない場合に失敗します。  これは、HPE ProLiant Agentless Management Service (<strong>AMS</strong>)およびHPE SNMPエージェント(<strong>SNMP Agents</strong>)の両方が実行されているときに発生します。  HPEでは、AMSおよびSNMPエージェントを同時に実行させないことを推奨します。  「iLO device not found」エラーが発生した場合、AMSまたはSNMPエージェントを停止させて、再度フラッシュコンポーネントを実行します。<br />\n<br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上のSmart Update Manager 8.0.0以降を使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant XL260a Gen9/XL2x260w (U24) Server"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant XL260a Gen9/XL2x260w (U24)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-02-22T21:35:28","revision_history":[{"lang":"en","latest_enhancements_x_late":null,"latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which, in combination with operating system updates, provides mitigation for Variant 2 of the Side Channel Analysis vulnerability, also known as Spectre. The revision of the microcode included in this System ROM does NOT have issues with more frequent reboots and unpredictable system behavior which impacted the previous Intel microcode which was part of the Spectre Variant 2 mitigation. Additional information is available from Intel&rsquo;s Security Exploit Newsroom, <a href=\"https://newsroom.intel.com/press-kits/security-exploits-intel-products/\">https://newsroom.intel.com/press-kits/security-exploits-intel-products/</a>.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>Updated the Intel processor microcode to the latest version.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>Ver. 1.60(B) contains updates to the component packaging and is functionally equivalent to ver. 1.60. It is not necessary to upgrade with Revision B if a previous component Revision was used to upgrade the firmware to version 1.60.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which, in combination with operating system updates, provides mitigation for Variant 2 of the Side Channel Analysis vulnerability, also known as Spectre. The revision of the microcode included in this System ROM does NOT have issues with more frequent reboots and unpredictable system behavior which impacted the previous Intel microcode which was part of the Spectre Variant 2 mitigation. Additional information is available from Intel&rsquo;s Security Exploit Newsroom, <a href=\"https://newsroom.intel.com/press-kits/security-exploits-intel-products/\">https://newsroom.intel.com/press-kits/security-exploits-intel-products/</a>.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>Updated the Intel processor microcode to the latest version.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U24","value":"HPE ProLiant XL2x260w Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"}],"sw_keys":[{"name":"U24","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component contains version 9.4.1.20 of the QLogic Storport driver which provides Mezzanine Fibre Channel Host Bus Adapter driver support for HPE storage arrays."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"1433496","datemodified":"2021-08-27T04:40:58","file_list":["cp049109.xml","cpqsetup.exe","install.xml","ql2300.cat","ql2300.sys","ql2x00.inf","QLOGIC","qlsrvc.exe","QlStorInstaller.dll","readme.txt","release.txt","SysConfig.frm","SysConfig.frm.ja","txtsetup.oem"],"md5sum":"3df364fffa09b99686604de6665b1eb5","name":"cp049109.exe","release":"2021-08-27T04:38:05","revision":"0","sha1sum":"7c55f3e9ed52f447c69d514f17730b15ca4dd365","size":"1MB","target_guids":[],"type_of_change":"1","version":"9.4.1.20"}],"id":{"product":"d00ceb206b8c4379bdd472d9eeb7502c","version":"548cd1dd2f0742fda1442c988bf225e0"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br />\n<br />\nFrom that drive and directory, execute the downloaded file.<br />\n<br />\nClick the &quot;Install&quot; button to proceed with the installation.<br />\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Mezzanine Fibre Channel Adapter Kit for the x64 QLogic Storport Driver for Microsoft Windows Server 2012R2"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-23T07:07:10","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Made improvements to the Fabric Port Identification Number (FPIN) and Universal Storage Area Network (SAN) Congestion Mitigation (USCM) Congestion Management algorithms.</li>\n</ul>\n\n<p>Updated&nbsp;to&nbsp;version&nbsp;9.4.1.20</p>\n","curr_fixes_x_late":"<ul>\n\t<li>Removed the &quot;fwload&quot; registry parameter.</li>\n\t<li>Fixed an unwanted behavior where Link up/down messages were not always logged in the Window System Event log.</li>\n\t<li>Fixed unwanted behavior with the reporting of Fabric Port Identification Number (FPIN) and Universal Storage Area Network (SAN) Congestion Mitigation (USCM) statistics.</li>\n\t<li>Fixed an unwanted behavior where connections to tape drives may fail to recover in the event of &quot;SCSI Check Condition&quot; commands or cable pulls.</li>\n\t<li>Fixed an unwanted behavior where the server may encounter a Blue Screen Of Death (BSOD) 0x0000009f message during shutdown as described in <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00116202en_us\">Advisory: HPE Host Bus Adapters - HPE Platforms Running a Microsoft Windows Server 2016 / 2019 Hyper-V Environment, and Configured With Certain HPE HBAs With the QLogic Storport Driver v9.4.2.20, May Experience a Bug Check 0x9F Event</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"ql2300.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB8000JFECQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRPSD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3842-3030-304a46454351","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following SAS drive models: MB8000JFECQ"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のSASドライブモデルのファームウェアを提供します。MB8000JFECQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB8000JFECQ Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD4</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong>&nbsp;&nbsp;&nbsp;&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp; None&nbsp;<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5678202","datemodified":"2021-07-23T07:47:14","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-252770cdda-HPD7-7.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-252770cdda-HPD7-7.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-252770cdda-HPD7-7.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-252770cdda-HPD7-7.1/CP048175.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-252770cdda-HPD7-7.1/SMKRPSD7.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-252770cdda-HPD7-7.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-252770cdda-HPD7-7.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-252770cdda-HPD7-7.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-252770cdda-HPD7-7.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048175.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048175.scexe"],"md5sum":"dc2624e0c5da788f2e23150f8fb99e21","name":"firmware-hdd-252770cdda-HPD7-7.1.x86_64.rpm","release":"2021-07-23T07:34:12","revision":"0","sha1sum":"37e11489813126ab7b1550173fe0a0d6cc5085bc","size":"5MB","target_guids":["002340a5-4d00-3842-3030-304a46454351"],"type_of_change":"1","version":"HPD7"}],"id":{"product":"cf9ee3d9e8f04b18823882812129b4e0","version":"85e64581f4844ae99247150add9ab062"},"installation":{"command":"CP040301.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB8000JFECQ Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB8000JFECQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB8000JFECQ","target_guid":"002340a5-4d00-3842-3030-304a46454351","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T20:09:16","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB8000JFECQ","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains drivers for the HPE QLogic FastLinQ 10/25/50 GbE Multifunction Adapters running under VMware vSphere 6.7."},{"lang":"ja","x_late":"この製品は、VMware vSphere 6.7上で動作するHPE QLogic FastLinQ 10/25/50 GbEマルチファンクションアダプター用のドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains the following drivers:</p>\n\n<ul>\n\t<li>qedf, version 2.2.62.0</li>\n\t<li>qedentv-ens, version 3.11.42.0</li>\n\t<li>qedrntv, version 3.11.40.0</li>\n\t<li>qedentv, version 3.11.41.0</li>\n\t<li>qedi, version 2.19.59.0</li>\n</ul>\n"}],"files":[{"bytes":"6258149","datemodified":"2021-08-11T13:39:36","file_list":["/cp047112.xml","/MRVL-E4-CNA-Driver-Bundle_4.0.270.0-1OEM.670.0.0.8169922-offline_bundle-18180569.zip","/MRVL-E4-CNA-Driver-Bundle_4.0.270.0-1OEM.670.0.0.8169922-offline_bundle-18180569.zip/index.xml","/MRVL-E4-CNA-Driver-Bundle_4.0.270.0-1OEM.670.0.0.8169922-offline_bundle-18180569.zip/vendor-index.xml","/MRVL-E4-CNA-Driver-Bundle_4.0.270.0-1OEM.670.0.0.8169922-offline_bundle-18180569.zip/metadata.zip","/MRVL-E4-CNA-Driver-Bundle_4.0.270.0-1OEM.670.0.0.8169922-offline_bundle-18180569.zip/vib20/qedentv-ens/QLC_bootbank_qedentv-ens_3.11.42.0-1OEM.670.0.0.8169922.vib","/MRVL-E4-CNA-Driver-Bundle_4.0.270.0-1OEM.670.0.0.8169922-offline_bundle-18180569.zip/vib20/qedentv/QLC_bootbank_qedentv_3.11.41.0-1OEM.670.0.0.8169922.vib","/MRVL-E4-CNA-Driver-Bundle_4.0.270.0-1OEM.670.0.0.8169922-offline_bundle-18180569.zip/vib20/qedi/QLC_bootbank_qedi_2.19.59.0-1OEM.670.0.0.8169922.vib","/MRVL-E4-CNA-Driver-Bundle_4.0.270.0-1OEM.670.0.0.8169922-offline_bundle-18180569.zip/vib20/qedrntv/QLC_bootbank_qedrntv_3.11.40.0-1OEM.670.0.0.8169922.vib","/MRVL-E4-CNA-Driver-Bundle_4.0.270.0-1OEM.670.0.0.8169922-offline_bundle-18180569.zip/vib20/qedf/QLC_bootbank_qedf_2.2.62.0-1OEM.670.0.0.8169922.vib","/MRVL-E4-CNA-Driver-Bundle_4.0.270.0-1OEM.670.0.0.8169922-offline_bundle-18180569.zip/metadata.zip/vendor-index.xml","/MRVL-E4-CNA-Driver-Bundle_4.0.270.0-1OEM.670.0.0.8169922-offline_bundle-18180569.zip/metadata.zip/vmware.xml","/MRVL-E4-CNA-Driver-Bundle_4.0.270.0-1OEM.670.0.0.8169922-offline_bundle-18180569.zip/metadata.zip/vibs/qedentv-ens--954399775122098528.xml","/MRVL-E4-CNA-Driver-Bundle_4.0.270.0-1OEM.670.0.0.8169922-offline_bundle-18180569.zip/metadata.zip/vibs/qedentv-258923251966823616.xml","/MRVL-E4-CNA-Driver-Bundle_4.0.270.0-1OEM.670.0.0.8169922-offline_bundle-18180569.zip/metadata.zip/vibs/qedi--2386401389613653085.xml","/MRVL-E4-CNA-Driver-Bundle_4.0.270.0-1OEM.670.0.0.8169922-offline_bundle-18180569.zip/metadata.zip/vibs/qedrntv-2720905648752635328.xml","/MRVL-E4-CNA-Driver-Bundle_4.0.270.0-1OEM.670.0.0.8169922-offline_bundle-18180569.zip/metadata.zip/vibs/qedf--7304507370759283955.xml","/MRVL-E4-CNA-Driver-Bundle_4.0.270.0-1OEM.670.0.0.8169922-offline_bundle-18180569.zip/metadata.zip/bulletins/MRVL-E4-CNA-Driver-Bundle_4.0.270.0-1OEM.670.0.0.8169922.xml"],"md5sum":"e38aae6d50cb0aeba8d9af1fe2d99bd7","name":"cp047112.zip","release":"2021-08-11T13:36:17","revision":"0","sha1sum":"9786a9667cb0beec8f6a18c256afa1acb46edcb9","size":"5MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec89e84beb","20a6e8e4-bf33-4c71-a6bf-d9ecd558d67b","20a6e8e4-bf33-4c71-a6bf-d9ec6a25bd0a","20a6e8e4-bf33-4c71-a6bf-d9ec5fbcae5e","20a6e8e4-bf33-4c71-a6bf-d9ec5685b43a"],"type_of_change":"0","version":"2021.09.04","vib_list":[{"name":"qedentv-ens","version":"3.11.42.0-1OEM.670.0.0.8169922"},{"name":"qedentv","version":"3.11.41.0-1OEM.670.0.0.8169922"},{"name":"qedi","version":"2.19.59.0-1OEM.670.0.0.8169922"},{"name":"qedrntv","version":"3.11.40.0-1OEM.670.0.0.8169922"},{"name":"qedf","version":"2.2.62.0-1OEM.670.0.0.8169922"}]}],"id":{"product":"2f321a74cb604b5798705f3942acaadd","version":"908915732b10409ab04a232cef5c8114"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic FastLinQ 10/25/50 GbE Multifunction Driver for VMware vSphere 6.7"},{"lang":"ja","x_late":"HPE QLogic FastLinQ 10/25/50 GbEマルチファンクションドライバー for VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"8070","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021d","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021f","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0074","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770074","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0073","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770073","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-807015900220","type":"pci","ven":"1077"},{"dev":"8070","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8070159002bd","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0070","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770070","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0069","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770069","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0068","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770068","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0071","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770071","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0072","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770072","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021a","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021b","type":"pci","ven":"1077"},{"dev":"8090","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8090159002bd","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-809015900220","type":"pci","ven":"1077"},{"dev":"8090","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80901590021d","type":"pci","ven":"1077"},{"dev":"8090","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80901590021f","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product addresses a Purple Screen Of Death (PSOD) seen on systems operating in a complicated VLAN environment.</p>\n"},{"curr_enhancements_x_late":"<p>This product enhances reliability via adding support for communication between firmware and drivers.</p>\n","curr_fixes_x_late":"<p>This product corrects an issue Vmkernel logs are flooding while running the traffic.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"qedentv:3.11.41.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qedrntv:3.11.40.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qedf:2.2.62.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qedentv-ens:3.11.42.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qedi:2.19.59.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox adapter cards."},{"lang":"ja","x_late":"このRPMには、サポートされているHPE Mellanoxアダプターカード用のHPEによるテストと承認済みのLinuxベースMellanox RoCE (RDMA over Converged Ethernet)ドライバーが含まれます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"2035211","datemodified":"2020-12-02T16:06:06","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/connectx.conf","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d/mlx4.driver","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/security/limits.d/30-libvma-limits.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/82-net-setup-link.rules","./etc/udev/rules.d/90-ib.rules","./sbin/connectx_port_config","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/ibdev2netdev","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_get_vfs.pl","./usr/bin/mlnx_perf","./usr/bin/mlnx_qcn","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/lib/python2.7/site-packages/dcbnetlink.py","./usr/lib/python2.7/site-packages/dcbnetlink.pyc","./usr/lib/python2.7/site-packages/dcbnetlink.pyo","./usr/lib/python2.7/site-packages/genetlink.py","./usr/lib/python2.7/site-packages/genetlink.pyc","./usr/lib/python2.7/site-packages/genetlink.pyo","./usr/lib/python2.7/site-packages/netlink.py","./usr/lib/python2.7/site-packages/netlink.pyc","./usr/lib/python2.7/site-packages/netlink.pyo","./usr/lib/python2.7/site-packages/ofed_le_utils-1.0.3-py2.7.egg-info","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/vma.service","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.0","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.0.0","./usr/lib64/libmlx4-rdmav2.so","./usr/lib64/libmlx5-rdmav2.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.0.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.0.0","./usr/lib64/libvma-debug.so","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.0.2","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vma","./usr/sbin/vmad","./usr/share/doc/packages/ib2ib","./usr/share/doc/packages/ib2ib/README","./usr/share/doc/packages/libibumad","./usr/share/doc/packages/libibumad/AUTHORS","./usr/share/doc/packages/libibumad/COPYING","./usr/share/doc/packages/libibumad/ChangeLog","./usr/share/doc/packages/libibverbs","./usr/share/doc/packages/libibverbs/AUTHORS","./usr/share/doc/packages/libibverbs/COPYING","./usr/share/doc/packages/libibverbs/ChangeLog","./usr/share/doc/packages/libibverbs/README","./usr/share/doc/packages/libmlx4","./usr/share/doc/packages/libmlx4/AUTHORS","./usr/share/doc/packages/libmlx4/COPYING","./usr/share/doc/packages/libmlx4/README","./usr/share/doc/packages/libmlx5","./usr/share/doc/packages/libmlx5/AUTHORS","./usr/share/doc/packages/libmlx5/COPYING","./usr/share/doc/packages/libmlx5/README","./usr/share/doc/packages/librdmacm","./usr/share/doc/packages/librdmacm/AUTHORS","./usr/share/doc/packages/librdmacm/COPYING","./usr/share/doc/packages/librdmacm/README","./usr/share/doc/packages/libvma-9.0.2/README.txt","./usr/share/doc/packages/libvma-9.0.2/VMA_VERSION","./usr/share/doc/packages/libvma-9.0.2/journal.txt","./usr/share/man/man3/umad_addr_dump.3.gz","./usr/share/man/man3/umad_alloc.3.gz","./usr/share/man/man3/umad_attribute_str.3.gz","./usr/share/man/man3/umad_class_str.3.gz","./usr/share/man/man3/umad_close_port.3.gz","./usr/share/man/man3/umad_debug.3.gz","./usr/share/man/man3/umad_done.3.gz","./usr/share/man/man3/umad_dump.3.gz","./usr/share/man/man3/umad_free.3.gz","./usr/share/man/man3/umad_free_ca_namelist.3.gz","./usr/share/man/man3/umad_get_ca.3.gz","./usr/share/man/man3/umad_get_ca_namelist.3.gz","./usr/share/man/man3/umad_get_ca_portguids.3.gz","./usr/share/man/man3/umad_get_cas_names.3.gz","./usr/share/man/man3/umad_get_fd.3.gz","./usr/share/man/man3/umad_get_issm_path.3.gz","./usr/share/man/man3/umad_get_mad.3.gz","./usr/share/man/man3/umad_get_mad_addr.3.gz","./usr/share/man/man3/umad_get_pkey.3.gz","./usr/share/man/man3/umad_get_port.3.gz","./usr/share/man/man3/umad_init.3.gz","./usr/share/man/man3/umad_mad_status_str.3.gz","./usr/share/man/man3/umad_method_str.3.gz","./usr/share/man/man3/umad_open_port.3.gz","./usr/share/man/man3/umad_poll.3.gz","./usr/share/man/man3/umad_recv.3.gz","./usr/share/man/man3/umad_register.3.gz","./usr/share/man/man3/umad_register2.3.gz","./usr/share/man/man3/umad_register_oui.3.gz","./usr/share/man/man3/umad_release_ca.3.gz","./usr/share/man/man3/umad_release_port.3.gz","./usr/share/man/man3/umad_send.3.gz","./usr/share/man/man3/umad_set_addr.3.gz","./usr/share/man/man3/umad_set_addr_net.3.gz","./usr/share/man/man3/umad_set_grh.3.gz","./usr/share/man/man3/umad_set_grh_net.3.gz","./usr/share/man/man3/umad_set_pkey.3.gz","./usr/share/man/man3/umad_size.3.gz","./usr/share/man/man3/umad_status.3.gz","./usr/share/man/man3/umad_unregister.3.gz","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml"],"md5sum":"b8403c268dc39dd8d0bd959cf554882e","name":"mlnx-ofa_kernel-4.9-OFED.4.9.2.2.4.1.1.sles15sp1.x86_64.rpm","release":"2020-12-02T14:22:07","revision":"0","sha1sum":"4c2e0c74af9087834ac18a1deedb1f3d3a1c3ed3","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5"],"type_of_change":"1","version":"4.9"},{"bytes":"1980634","datemodified":"2020-12-02T16:08:47","file_list":["./lib/modules/4.12.14-195-default","./lib/modules/4.12.14-195-default/updates","./lib/modules/4.12.14-195-default/updates/compat","./lib/modules/4.12.14-195-default/updates/compat/mlx_compat.ko","./lib/modules/4.12.14-195-default/updates/drivers","./lib/modules/4.12.14-195-default/updates/drivers/infiniband","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/core","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/core/ib_cm.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/core/ib_core.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/core/ib_ucm.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/core/ib_umad.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/core/iw_cm.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/core/rdma_cm.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/cxgb3","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/cxgb3/iw_cxgb3.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/cxgb4","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/efa","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/efa/efa.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/hfi1","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/i40iw","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/mlx4","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/mlx5","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/mthca","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/mthca/ib_mthca.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/nes","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/nes/iw_nes.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/ocrdma","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/ocrdma/ocrdma.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/qedr","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/qib","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/qib/ib_qib.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/usnic","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/sw","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/sw/rdmavt","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/sw/rxe","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/ulp","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/ulp/ipoib","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/ulp/iser","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/ulp/isert","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/ulp/opa_vnic","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/ulp/srp","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/ulp/srpt","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/4.12.14-195-default/updates/drivers/net","./lib/modules/4.12.14-195-default/updates/drivers/net/ethernet","./lib/modules/4.12.14-195-default/updates/drivers/net/ethernet/mellanox","./lib/modules/4.12.14-195-default/updates/drivers/net/ethernet/mellanox/mlx4","./lib/modules/4.12.14-195-default/updates/drivers/net/ethernet/mellanox/mlx4/mlx4_core.ko","./lib/modules/4.12.14-195-default/updates/drivers/net/ethernet/mellanox/mlx4/mlx4_en.ko","./lib/modules/4.12.14-195-default/updates/drivers/net/ethernet/mellanox/mlx5","./lib/modules/4.12.14-195-default/updates/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/4.12.14-195-default/updates/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/4.12.14-195-default/updates/drivers/net/ethernet/mellanox/mlx5/fpga","./lib/modules/4.12.14-195-default/updates/drivers/net/ethernet/mellanox/mlx5/fpga/mlx5_fpga_tools.ko","./lib/modules/4.12.14-195-default/updates/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/4.12.14-195-default/updates/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/4.12.14-195-default/updates/drivers/nvme","./lib/modules/4.12.14-195-default/updates/drivers/nvme/host","./lib/modules/4.12.14-195-default/updates/drivers/nvme/host/nvme-rdma.ko","./lib/modules/4.12.14-195-default/updates/drivers/nvme/target","./lib/modules/4.12.14-195-default/updates/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/4.12.14-195-default/updates/drivers/vfio","./lib/modules/4.12.14-195-default/updates/drivers/vfio/mdev","./lib/modules/4.12.14-195-default/updates/drivers/vfio/mdev/i915.ko","./lib/modules/4.12.14-195-default/updates/drivers/vfio/mdev/kvmgt.ko","./lib/modules/4.12.14-195-default/updates/drivers/vfio/mdev/mdev.ko","./lib/modules/4.12.14-195-default/updates/drivers/vfio/mdev/vfio_mdev.ko","./lib/modules/4.12.14-195-default/updates/net","./lib/modules/4.12.14-195-default/updates/net/9p","./lib/modules/4.12.14-195-default/updates/net/9p/9pnet_rdma.ko","./lib/modules/4.12.14-195-default/updates/net/rds","./lib/modules/4.12.14-195-default/updates/net/rds/rds_rdma.ko","./lib/modules/4.12.14-195-default/updates/net/sunrpc","./lib/modules/4.12.14-195-default/updates/net/sunrpc/xprtrdma","./lib/modules/4.12.14-195-default/updates/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/4.12.14-195-default/updates/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/4.12.14-195-default/updates/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/mlnx-ofa_kernel-kmp-default/component.xml"],"md5sum":"18372d86af11e5c6654e32974521d382","name":"mlnx-ofa_kernel-kmp-default-4.9_k4.12.14_195-OFED.4.9.2.2.4.1.sles15sp1.x86_64.rpm","release":"2020-12-02T14:22:07","revision":"0","sha1sum":"1cc3e577c1e7c851cb60e3f5b6edacc344590940","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5"],"type_of_change":"1","version":"4.9"}],"id":{"product":"ecc46179b9da4907abbf4738a44b1dc2","version":"16bba50e634d45d9b60de2834208dcc7"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"11.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPMs to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-4.9.&quot; RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using 4.12.14-195-default&nbsp;kernel or any future errata:<br />\n<br />\n<strong># rpm -Uvh&nbsp;mlnx-ofa_kernel-4.9-OFED.4.9.2.2.4.1.1.sles15sp1.x86_64.rpm&nbsp;mlnx-ofa_kernel-kmp-default-4.9_k4.12.14_195-OFED.4.9.2.2.4.1.sles15sp1.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for SUSE LINUX Enterprise Server 15 SP1 (AMD64/EM64T)"},{"lang":"ja","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet)ドライバー for SUSE LINUX Enterprise Server 15 SP1 (AMD64/EM64T)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-02T08:40:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>The following changes and new features are added in version 4.9:</strong></p>\n\n<ul>\n\t<li><strong>For ConnectX-5 Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Option to dump configuration space via the devlink tool in order to improve debug capabilities.</li>\n\t<li>The conventional TX descriptor (WQE or Work Queue Element) describes a single packet for transmission. Added driver support for the HW feature of multi-packet TX WQEs in XDP transmit flows. With this, the HW becomes capable of working with a new and improved WQE layout that describes several packets. In effect, this feature saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>GENEVE encapsulation/decapsulation rules offload.</li>\n\t<li>Driver support for the hardware feature of multi-packet Tx to work with a new and improved WQE layout that describes several packets instead of a single packet for XDP transmission flows. This saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>Updating CT (Connection Tracking) rules using the software steering mechanism.</li>\n\t<li>Updating remote mirroring rules using the software steering mechanism.<br />\n\t&nbsp;</li>\n\t<li><strong>For ConnectX-4&nbsp;Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Exposed rx_prio[p]_discards discard counters per priority that count the number of received packets dropped due to lack of buffers on the physical port.</li>\n\t<li>Reporting TSO and CSUM offload capabilities for MPLS tagged traffic and, allowed the kernel stack to use these offloads.</li>\n\t<li>mlx5e Max Combined Channels Increased the driver&rsquo;s maximal combined channels value from 64 to 128 (however, note that OOB value will not cross 64). 128 is the upper bound. Lower maximal value can be seen on the host, depending on the number of cores and MSIX&#39;s configured by the firmware.</li>\n\t<li>Added the following RoCE accelerator counters:\n\t<ul>\n\t\t<li>roce_adp_retrans - counts the number of adaptive retransmissions for RoCE traffic.</li>\n\t\t<li>roce_adp_retrans_to - counts the number of times RoCE traffic reached timeout due to adaptive retransmission.</li>\n\t\t<li>roce_slow_restart - counts the number of times RoCE slow restart was used.</li>\n\t\t<li>roce_slow_restart_cnps - counts the number of times RoCE slow restart generated CNP packets roce_slow_restart_trans - counts the number of times RoCE slow restart changed state to slow restart.</li>\n\t</ul>\n\t</li>\n\t<li>User to register memory regions with a relaxed ordering access flag through experimental verbs. This can enhance performance, depending on architecture and scenario.<br />\n\t&nbsp;</li>\n\t<li><strong>For&nbsp;All HCA&#39;s</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Output ibdev2netdev tool output was changed such that the bonding device now points at the bond instead of the slave interface.</li>\n\t<li>Monitoring and recovering from errors that occur on the RX queue, such as cookie errors and timeout.</li>\n\t<li>Improved GSO (Generic Segmentation Offload) workload performance by decreasing doorbells usage to the minimum required.</li>\n\t<li>TX CQE (Completion Queue Element) compression. Saves on outgoing PCIe bandwidth by compressing CQEs together. Disabled by default. Configurable via private flags of ethtool.</li>\n\t<li>Firmware Versions Query via Devlink :Added the option to query for running and stored firmware versions using the devlink tool.</li>\n\t<li>Firmware Flash Update via Devlink :Added the option to update the firmware image in the flash using the devlink tool. Usage: devlink dev flash file .mfa2 For further information on how to perform this update, see &quot;Updating Firmware Using ethtool/devlink and .mfa2 File&quot; section in MFT User Manual.</li>\n\t<li>WQE (Work Queue Element) dump, triggered by an error on Rx/Tx reporters. In addition, some dumps (not triggered by an error) can be retrieved by the user via devlink health reporters.</li>\n\t<li>GENEVE tunneled hardware offloads of TSO, CSUM and RSS.</li>\n\t<li>TCP segmentation and checksum offload support for MPLS-tagged traffic.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 4.9:</strong></p>\n\n<ul>\n\t<li>An issue where injecting EEH (Extended Error Handlng) may cause extra Kernel prints, such as: &ldquo;EEH: Might be infinite loop in mlx5_core driver&rdquo; was fixed.</li>\n\t<li>RPM-based OSs with non-default kernels, using repositories after re-creating the installer (using --add-kernel-support) were&nbsp;resulting&nbsp;in improper installation of the drivers.</li>\n\t<li>A typo in perftest package where help messages wrongly displayed the conversion result between Gb/s and MB/s (20^2 instead of 2^20).</li>\n\t<li>When one of the LAG slaves went down, LAG deactivation failed, ultimately causing bandwidth degradation.</li>\n\t<li>The mlx5 driver maintains a subdirectory for every open eth port in /sys/kernel/debug/. For the default network namespace, the sub-directory name is the name of the interface, like &quot;eth8&quot;. The new convention for the network interfaces moved to the non-default network namespaces is the interfaces name followed by &quot;@&quot; and the port&#39;s PCI ID. For example: &quot;eth8@0000:af:00.3&quot;.</li>\n\t<li>&quot;openibd&quot; script load used to fail when esp6_offload module did not load successfully.</li>\n\t<li>Added dependency of package mpi-selectors on perl-Getopt-Long system package. On minimal installs of RPM-based OSs, installing mpi-selectros will also install the required system package perl-Getopt-Long.</li>\n\t<li>During certain rare scenarios, due to Rx page not being replenished, the same page fragment mistakenly became assigned to two different Rx descriptors.</li>\n\t<li>Driver load issue existed with Errata-kernel on SLES15 SP1.</li>\n\t<li>An issue in the Hairpin feature which prevented adding hairpin flows using TC tool was fixed.</li>\n\t<li>WQ (Work Queue)&nbsp;queue flushing was not handled properly in the event of EEH.</li>\n\t<li>A rare kernel crash scenario when exiting an application that uses RMPP mads intensively.</li>\n\t<li>A possible kernel crash scenario when AER/slot reset in done in parallel to user space commands execution.</li>\n\t<li>Added missing ECN (Explicit Congestion Notification) configuration under sysfs for PFs in SwitchDev mode.</li>\n\t<li>When firmware response time to commands became very long, some commands failed upon timeout. The driver may have then triggered a timeout completion on the wrong entry, leading to a NULL pointer call trace.</li>\n\t<li>Added driver support for kernels with the old XDP_REDIRECT infrastructure that uses the following NetDev operations: .ndo_xdp_flush and .ndo_xdp_xmit.</li>\n\t<li>Usage of --excludedocs Open MPI RPM option resulted in the removal of non-documentation related files.</li>\n\t<li>Disabled automated loading of some modules through udev triggers to preserve the startup process of previous MLNX_OFED versions.</li>\n\t<li>Reference count (refcount) for RDMA connection ID (cm_id) was not incremented in rdma_resolve_addr() function, resulting in a cm_id use-after-free access. A fix was applied to increment the cm_id refcount</li>\n\t<li>A race condition which caused kernel panic when moving two ports to SwitchDev mode at the same time.</li>\n\t<li>Allowed accessing sysfs hardware counters in SwitchDev mode</li>\n\t<li>Function smp_processor_id() is called in the RX page recycle flow to determine the core to run on. This is intended to run in NAPI context. However, due to a bug in backporting, the RX page recycle was mistakenly called also in the RQ close flow when not needed.</li>\n\t<li>Port link state was automatically changed (without admin state involvement) to &quot;UP&quot; after reboot.</li>\n\t<li>ConnectX-3 adapter cards froze when running over SLES 11 OS.</li>\n\t<li>RDMA CM (Remote Direct Memory Access Communation Manager) connection failed when port space was small.</li>\n\t<li>Traffic mirroring with OVS (Open VSwitch)offload and non-offload over VxLAN interface is now supported. Note: For kernel 4.9, make sure to use a dedicated OVS version.</li>\n\t<li>When working with VF LAG while the bond device is in active-active mode, running fwreset would result in unequal traffic on both PFs, and PFs would not reach line rate.</li>\n\t<li>When bond was created over VF (Virtuaal Function)&nbsp;netdevices in SwitchDev mode, the VF netdevice would be treated as representor netdevice. This caused the mlx5_core driver to crash in case it received netdevice events related to bond device.</li>\n\t<li>An issue where following a bad affinity occurrence in VF LAG mode, traffic was sent after the port went up/down in the switch.</li>\n\t<li>Added support for VLAN (Virtual Local Area Network)&nbsp;header rewrite on CentOS 7.2 OS.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>The following changes and new features are added in version 4.9:</strong></p>\n\n<ul>\n\t<li><strong>For ConnectX-5 Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Option to dump configuration space via the devlink tool in order to improve debug capabilities.</li>\n\t<li>The conventional TX descriptor (WQE or Work Queue Element) describes a single packet for transmission. Added driver support for the HW feature of multi-packet TX WQEs in XDP transmit flows. With this, the HW becomes capable of working with a new and improved WQE layout that describes several packets. In effect, this feature saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>GENEVE encapsulation/decapsulation rules offload.</li>\n\t<li>Driver support for the hardware feature of multi-packet Tx to work with a new and improved WQE layout that describes several packets instead of a single packet for XDP transmission flows. This saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>Updating CT (Connection Tracking) rules using the software steering mechanism.</li>\n\t<li>Updating remote mirroring rules using the software steering mechanism.<br />\n\t&nbsp;</li>\n\t<li><strong>For ConnectX-4&nbsp;Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Exposed rx_prio[p]_discards discard counters per priority that count the number of received packets dropped due to lack of buffers on the physical port.</li>\n\t<li>Reporting TSO and CSUM offload capabilities for MPLS tagged traffic and, allowed the kernel stack to use these offloads.</li>\n\t<li>mlx5e Max Combined Channels Increased the driver&rsquo;s maximal combined channels value from 64 to 128 (however, note that OOB value will not cross 64). 128 is the upper bound. Lower maximal value can be seen on the host, depending on the number of cores and MSIX&#39;s configured by the firmware.</li>\n\t<li>Added the following RoCE accelerator counters:\n\t<ul>\n\t\t<li>roce_adp_retrans - counts the number of adaptive retransmissions for RoCE traffic.</li>\n\t\t<li>roce_adp_retrans_to - counts the number of times RoCE traffic reached timeout due to adaptive retransmission.</li>\n\t\t<li>roce_slow_restart - counts the number of times RoCE slow restart was used.</li>\n\t\t<li>roce_slow_restart_cnps - counts the number of times RoCE slow restart generated CNP packets roce_slow_restart_trans - counts the number of times RoCE slow restart changed state to slow restart.</li>\n\t</ul>\n\t</li>\n\t<li>User to register memory regions with a relaxed ordering access flag through experimental verbs. This can enhance performance, depending on architecture and scenario.<br />\n\t&nbsp;</li>\n\t<li><strong>For&nbsp;All HCA&#39;s</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Output ibdev2netdev tool output was changed such that the bonding device now points at the bond instead of the slave interface.</li>\n\t<li>Monitoring and recovering from errors that occur on the RX queue, such as cookie errors and timeout.</li>\n\t<li>Improved GSO (Generic Segmentation Offload) workload performance by decreasing doorbells usage to the minimum required.</li>\n\t<li>TX CQE (Completion Queue Element) compression. Saves on outgoing PCIe bandwidth by compressing CQEs together. Disabled by default. Configurable via private flags of ethtool.</li>\n\t<li>Firmware Versions Query via Devlink :Added the option to query for running and stored firmware versions using the devlink tool.</li>\n\t<li>Firmware Flash Update via Devlink :Added the option to update the firmware image in the flash using the devlink tool. Usage: devlink dev flash file .mfa2 For further information on how to perform this update, see &quot;Updating Firmware Using ethtool/devlink and .mfa2 File&quot; section in MFT User Manual.</li>\n\t<li>WQE (Work Queue Element) dump, triggered by an error on Rx/Tx reporters. In addition, some dumps (not triggered by an error) can be retrieved by the user via devlink health reporters.</li>\n\t<li>GENEVE tunneled hardware offloads of TSO, CSUM and RSS.</li>\n\t<li>TCP segmentation and checksum offload support for MPLS-tagged traffic.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 4.9:</strong></p>\n\n<ul>\n\t<li>An issue where injecting EEH (Extended Error Handlng) may cause extra Kernel prints, such as: &ldquo;EEH: Might be infinite loop in mlx5_core driver&rdquo; was fixed.</li>\n\t<li>RPM-based OSs with non-default kernels, using repositories after re-creating the installer (using --add-kernel-support) were&nbsp;resulting&nbsp;in improper installation of the drivers.</li>\n\t<li>A typo in perftest package where help messages wrongly displayed the conversion result between Gb/s and MB/s (20^2 instead of 2^20).</li>\n\t<li>When one of the LAG slaves went down, LAG deactivation failed, ultimately causing bandwidth degradation.</li>\n\t<li>The mlx5 driver maintains a subdirectory for every open eth port in /sys/kernel/debug/. For the default network namespace, the sub-directory name is the name of the interface, like &quot;eth8&quot;. The new convention for the network interfaces moved to the non-default network namespaces is the interfaces name followed by &quot;@&quot; and the port&#39;s PCI ID. For example: &quot;eth8@0000:af:00.3&quot;.</li>\n\t<li>&quot;openibd&quot; script load used to fail when esp6_offload module did not load successfully.</li>\n\t<li>Added dependency of package mpi-selectors on perl-Getopt-Long system package. On minimal installs of RPM-based OSs, installing mpi-selectros will also install the required system package perl-Getopt-Long.</li>\n\t<li>During certain rare scenarios, due to Rx page not being replenished, the same page fragment mistakenly became assigned to two different Rx descriptors.</li>\n\t<li>Driver load issue existed with Errata-kernel on SLES15 SP1.</li>\n\t<li>An issue in the Hairpin feature which prevented adding hairpin flows using TC tool was fixed.</li>\n\t<li>WQ (Work Queue)&nbsp;queue flushing was not handled properly in the event of EEH.</li>\n\t<li>A rare kernel crash scenario when exiting an application that uses RMPP mads intensively.</li>\n\t<li>A possible kernel crash scenario when AER/slot reset in done in parallel to user space commands execution.</li>\n\t<li>Added missing ECN (Explicit Congestion Notification) configuration under sysfs for PFs in SwitchDev mode.</li>\n\t<li>When firmware response time to commands became very long, some commands failed upon timeout. The driver may have then triggered a timeout completion on the wrong entry, leading to a NULL pointer call trace.</li>\n\t<li>Added driver support for kernels with the old XDP_REDIRECT infrastructure that uses the following NetDev operations: .ndo_xdp_flush and .ndo_xdp_xmit.</li>\n\t<li>Usage of --excludedocs Open MPI RPM option resulted in the removal of non-documentation related files.</li>\n\t<li>Disabled automated loading of some modules through udev triggers to preserve the startup process of previous MLNX_OFED versions.</li>\n\t<li>Reference count (refcount) for RDMA connection ID (cm_id) was not incremented in rdma_resolve_addr() function, resulting in a cm_id use-after-free access. A fix was applied to increment the cm_id refcount</li>\n\t<li>A race condition which caused kernel panic when moving two ports to SwitchDev mode at the same time.</li>\n\t<li>Allowed accessing sysfs hardware counters in SwitchDev mode</li>\n\t<li>Function smp_processor_id() is called in the RX page recycle flow to determine the core to run on. This is intended to run in NAPI context. However, due to a bug in backporting, the RX page recycle was mistakenly called also in the RQ close flow when not needed.</li>\n\t<li>Port link state was automatically changed (without admin state involvement) to &quot;UP&quot; after reboot.</li>\n\t<li>ConnectX-3 adapter cards froze when running over SLES 11 OS.</li>\n\t<li>RDMA CM (Remote Direct Memory Access Communation Manager) connection failed when port space was small.</li>\n\t<li>Traffic mirroring with OVS (Open VSwitch)offload and non-offload over VxLAN interface is now supported. Note: For kernel 4.9, make sure to use a dedicated OVS version.</li>\n\t<li>When working with VF LAG while the bond device is in active-active mode, running fwreset would result in unequal traffic on both PFs, and PFs would not reach line rate.</li>\n\t<li>When bond was created over VF (Virtuaal Function)&nbsp;netdevices in SwitchDev mode, the VF netdevice would be treated as representor netdevice. This caused the mlx5_core driver to crash in case it received netdevice events related to bond device.</li>\n\t<li>An issue where following a bad affinity occurrence in VF LAG mode, traffic was sent after the port went up/down in the switch.</li>\n\t<li>Added support for VLAN (Virtual Local Area Network)&nbsp;header rewrite on CentOS 7.2 OS.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE ProLiant Smart Array Px4x and Hx4x series controllers. This RPM provides a customer friendly approach to install a pre-built binary driver.\nOn some kernel erratas the version of the driver present in the kernel may be equal to the version being installed by the rpm.  However, the driver in the kernel may not include all of the fixes and enhancements implemented in the driver contained within the rpm.  Therefore the rpm should be installed in order to obtain the fixes and enhancements that are not present in the kernel driver."},{"lang":"ja","x_late":"このRPMは、HPE ProLiant SmartアレイPx4xおよびHx4xシリーズコントローラーを有効にするためのプレビルドバイナリドライバーモジュールを提供します。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。errataカーネルによっては、カーネル内に存在するドライバーのバージョンとrpmによってインストールされたバージョンが等しい場合があります。だたし、カーネル内のドライバーは、rpmに含まれるドライバーに対して行われた、すべての修正と拡張が含まれていないことがあります。そのため、rpmはカーネルドライバーに存在しない、修正と拡張を入手するため、インストールする必要があります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"74607","datemodified":"2021-05-28T12:51:45","file_list":["./etc/depmod.d/hpsa.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/hpsa","./lib/modules/3.10.0-1160.el7.x86_64/extra/hpsa/hpsa.ko","./usr/share/smartupdate/kmod-hpsa/component.xml"],"md5sum":"eb0b980fe87e4960c7faa27e91d6e207","name":"kmod-hpsa-3.4.20-208.rhel7u9.x86_64.rpm","release":"2021-05-28T12:44:05","revision":"0","sha1sum":"7275317ac0328bd174c164a8f50c547bb43385f2","size":"72KB","target_guids":[],"type_of_change":"1","version":"3.4.20-208"},{"bytes":"74616","datemodified":"2021-05-28T12:52:51","file_list":["./etc/depmod.d/hpsa.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/hpsa","./lib/modules/3.10.0-1127.el7.x86_64/extra/hpsa/hpsa.ko","./usr/share/smartupdate/kmod-hpsa/component.xml"],"md5sum":"057c95bc43e7d4b106f4e4c19fb0d3f6","name":"kmod-hpsa-3.4.20-208.rhel7u8.x86_64.rpm","release":"2021-05-28T12:44:05","revision":"0","sha1sum":"c2b84c7c4f6392a0c1b0e93ccb8c0895c11cd988","size":"72KB","target_guids":[],"type_of_change":"1","version":"3.4.20-208"}],"id":{"product":"438f6bb803b440feb816d6663cff3bca","version":"19c39e0b8ae14623982694149d41adca"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as the system administrator (root), download the RPM to a directory on<br />\nyour hard drive and change to that directory.</p>\n\n<p><strong>To install or upgrade&nbsp;the driver type:</strong></p>\n\n<ul>\n\t<li># rpm -Uvh kmod-hpsa-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm&nbsp;&nbsp;</li>\n</ul>\n\n<p style=\"margin-right:0px\">Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p><strong>NOTE</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:</p>\n\n<ul>\n\t<li># rpm -e kmod-hpsa-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong><u>Enterprise Support</u></strong><br />\nFor support on Smart Array controllers, visit <a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a></p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>システム管理者（root）としてログインし、RPMを<br />\nご使用のハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</p>\n\n<p><strong>ドライバーをインストールまたはアップグレードするには次のようにタイプします。</strong></p>\n\n<ul>\n\t<li># rpm -Uvh kmod-hpsa-<version>.<OSupdate>.x86_64.rpm  </li>\n</ul>\n\n<p style=\"margin-right:0px\">Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p><strong>注</strong>：インストールの失敗、あるいは警告やエラーメッセージを表示して停止した場合は、コンピューターを再起動しないでください。ドライバーは動作しないため、以下のコマンドをタイプしてアンインストールしてください。</p>\n\n<ul>\n\t<li># rpm -e kmod-hpsa-<version>.<OSupdate>.x86_64.rpm</li>\n</ul>\n\n<p> </p>\n\n<p><strong><u>Enterprise Support</u></strong><br />\nSmartアレイコントローラーのサポートに関しては、<a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a>を参照してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE ProLiant Smart Array Controller (64-bit) Driver for Red Hat Enterprise Linux 7 (64-bit)"},{"lang":"ja","x_late":"Red Hat Enterprise Linux 7（64-bit）用HPE ProLiant Smartアレイコントローラー（64-bit）ドライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"323c","subdev":"1928","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21BD","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ca","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1922","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1923","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c2","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c0","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c3","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1926","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21be","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3353","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1924","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1921","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cb","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c1","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c5","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21CD","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cc","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3355","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3350","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3351","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3354","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3352","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323B","subdev":"3356","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3239","subdev":"21c7","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21bf","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c8","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c6","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ce","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T12:17:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Add support for Red Hat Enterprise Linux 7 Update 9</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial Version</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P74","value":"HP ProLiant SL140s Gen8 Server (private)"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 v2 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"P83","value":"HP ProLiant SL210t Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I14","value":"HP ProLiant BL480c Server"}],"sw_keys":[{"name":"kmod-hpsa","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hpsa","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hpsa","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hpsa","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO007680JWCNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633HD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304a57434e4b","Version":"HPD8"},{"DeviceName":"VO015300JWCNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633HD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3330-304a57434e4c","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO007680JWCNK and VO015300JWCNL"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO007680JWCNKおよびVO015300JWCNL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VO007680JWCNK and VO015300JWCNL&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5275209","datemodified":"2021-07-23T09:02:39","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-4c048aaeb0-HPD8-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-4c048aaeb0-HPD8-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-4c048aaeb0-HPD8-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-4c048aaeb0-HPD8-4.1/CP048195.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-4c048aaeb0-HPD8-4.1/G1633HD8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-4c048aaeb0-HPD8-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-4c048aaeb0-HPD8-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-4c048aaeb0-HPD8-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-4c048aaeb0-HPD8-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048195.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048195.scexe"],"md5sum":"e25d2d0afe702d53da9cfe08b6b1b2c1","name":"firmware-hdd-4c048aaeb0-HPD8-4.1.x86_64.rpm","release":"2021-07-23T08:50:10","revision":"0","sha1sum":"f8fc36aad5e2b2ce8a8cff7161415eeef4c502c0","size":"5MB","target_guids":["562340a5-304f-3730-3638-304a57434e4b","562340a5-304f-3531-3330-304a57434e4c"],"type_of_change":"2","version":"HPD8"}],"id":{"product":"3207ab7da97d4b129737d7c53c2ebb76","version":"2436129571374ec48c21bc0e26cbc074"},"installation":{"command":"CP042624.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VO007680JWCNK and VO015300JWCNL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VO007680JWCNKおよびVO015300JWCNLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VO015300JWCNL","target_guid":"562340a5-304f-3531-3330-304a57434e4c","type":"sas"},{"id":"VO007680JWCNK","target_guid":"562340a5-304f-3730-3638-304a57434e4b","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T10:41:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO007680JWCNK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO015300JWCNL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the HPE QLogic userspace IO daemon that provides ARP/DHCP support for iSCSI offload for QLogic NX2 Multifunction Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 12 SP3."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12 SP3で動作するBlade QLogicマルチファンクションGigabit Ethernet NICのiSCSIオフロード用のARP/DHCPサポートを提供するHPE Blade QLogic userspace IO Daemonが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"101615","datemodified":"2020-02-12T18:42:06","file_list":["./etc/logrotate.d/iscsiuiolog","./sbin/iscsiuio","./usr/lib/.build-id","./usr/lib/.build-id/e1","./usr/lib/.build-id/e1/57ef6ded0ab349b14e94046722a43e0164dde6","./usr/share/man/man8/iscsiuio.8.gz","./usr/share/smartupdate/iscsiuio_bl/component.xml"],"md5sum":"0ea3dc41962b9194ccf67a9bd81fb603","name":"iscsiuio_bl-2.11.5.13-3.sles12sp3.x86_64.rpm","release":"2020-02-12T18:41:04","revision":"0","sha1sum":"1ee272253edaa7522a85410489597a367278c8e4","size":"99KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf9413ac8"],"type_of_change":"0","version":"2.11.5.13-3"}],"id":{"product":"fdecd8de3b2448668fbc68e73736a3fc","version":"deac96d1c675459f8f95ac0aa828e2bb"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"},{"lang":"ja","x_late":"<p>インストールのノートについてREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade QLogic NX2 iSCSI Offload IO Daemon for SUSE Linux Enterprise Server 12 SP3"},{"lang":"ja","x_late":"HPE Blade QLogic iSCSI Offload IO Daemon for SUSE Linux Enterprise Server 12 SP3"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"168E","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1933","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c22fa","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1917","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1916","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1933","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c22fa","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1916","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1917","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-03-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":"<p>This product addresses an&nbsp;iSCSI discovery failure with VLAN.</p>\n\n<p>This product addresses an issue where&nbsp;an iSCSI portal is&nbsp;discovered with invalid an VLAN ID.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product has&nbsp;been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"iscsiuio_bl","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWUDA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEBHasseFG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304757554441","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB014000GWUDA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB014000GWUDA Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"18956113","datemodified":"2021-08-26T14:41:29","file_list":["/CP048339_BUILD_2.data","/CP048339.vmexe","/CP048339.vmexe64","/CP048339.vmfile","/CP048339_VMw.zip","/CP048339.xml","/payload.json","/CP048339_VMw.zip/index.xml","/CP048339_VMw.zip/vendor-index.xml","/CP048339_VMw.zip/metadata.zip","/CP048339_VMw.zip/vib20/CP048339/HPE_bootbank_CP048339_HPG2.2-7.0.0.15843807.vib","/CP048339_VMw.zip/metadata.zip/vendor-index.xml","/CP048339_VMw.zip/metadata.zip/vmware.xml","/CP048339_VMw.zip/metadata.zip/vibs/CP048339-8592399725772804382.xml","/CP048339_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048339_HPG2.2-7.0.0.15843807.xml"],"md5sum":"7c2810ee9fe4555c3646d5e55c744b85","name":"CP048339.zip","release":"2021-08-26T14:36:22","revision":"0","sha1sum":"1f9b5d53ed16d56936165e901056bde2d4f97922","size":"18MB","target_guids":["4d2340a5-3042-3431-3030-304757554441"],"type_of_change":"1","version":"HPG2","vib_list":[{"name":"CP048339","version":"HPG2.2-7.0.0.15843807"}]}],"id":{"product":"eaadba373a2b4b7ab82c00e6e1f55628","version":"ff41fa60b1ff47ba92ced9071df729d2"},"installation":{"command":"CP041507.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB014000GWUDA Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB014000GWUDAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB014000GWUDA","target_guid":"4d2340a5-3042-3431-3030-304757554441","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-06T12:36:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB014000GWUDA","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK001920KWDUH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304b57445548","Version":"HPK4"},{"DeviceName":"MK001600KWDUN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3630-304b5744554e","Version":"HPK4"},{"DeviceName":"VK000960KWDUF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304b57445546","Version":"HPK4"},{"DeviceName":"MK000800KWDUL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3830-304b5744554c","Version":"HPK4"},{"DeviceName":"VK000480KWDUE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304b57445545","Version":"HPK4"},{"DeviceName":"MK000400KWDUK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3430-304b5744554b","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MK000400KWDUK, VK000480KWDUE, MK000800KWDUL, VK000960KWDUF, MK001600KWDUN, and VK001920KWDUH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for Windows&nbsp;(x64) - MK000400KWDUK, VK000480KWDUE, MK000800KWDUL, VK000960KWDUF, MK001600KWDUN and VK001920KWDUH Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp;</strong>&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"6219616","datemodified":"2021-07-24T11:14:50","file_list":["cp048479.xml","cpqsetup.exe","payload.json","setup.dll","spannsK4.rel"],"md5sum":"7b95fbb7a68d9084b8401172d2f7a6fc","name":"cp048479.exe","release":"2021-07-24T11:07:10","revision":"0","sha1sum":"8e46104d5b2ff30bb1fe26d317b45ddd142112db","size":"5MB","target_guids":["562340a5-304b-3130-3932-304b57445548","4d2340a5-304b-3130-3630-304b5744554e","562340a5-304b-3030-3936-304b57445546","4d2340a5-304b-3030-3830-304b5744554c","562340a5-304b-3030-3438-304b57445545","4d2340a5-304b-3030-3430-304b5744554b"],"type_of_change":"1","version":"HPK4"}],"id":{"product":"d06d054af702418fa905eb8595ceb958","version":"4a9971b4e5f9496b9c87053d2cda135a"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) -  MK000400KWDUK, VK000480KWDUE, MK000800KWDUL, VK000960KWDUF, MK001600KWDUN and VK001920KWDUH Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - MK000400KWDUK、VK000480KWDUE、MK000800KWDUL、VK000960KWDUF、MK001600KWDUN、およびVK001920KWDUHドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MK000400KWDUK","target_guid":"4d2340a5-304b-3030-3430-304b5744554b","type":"nvme"},{"id":"MK000800KWDUL","target_guid":"4d2340a5-304b-3030-3830-304b5744554c","type":"nvme"},{"id":"MK001600KWDUN","target_guid":"4d2340a5-304b-3130-3630-304b5744554e","type":"nvme"},{"id":"VK000480KWDUE","target_guid":"562340a5-304b-3030-3438-304b57445545","type":"nvme"},{"id":"VK000960KWDUF","target_guid":"562340a5-304b-3030-3936-304b57445546","type":"nvme"},{"id":"VK001920KWDUH","target_guid":"562340a5-304b-3130-3932-304b57445548","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T18:32:46","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK000960KWDUF","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK001920KWDUH","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK000800KWDUL","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK001600KWDUN","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK000400KWDUK","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK000480KWDUE","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter and mezzanine host bus adapters. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"5665691","datemodified":"2021-08-27T03:39:46","file_list":["./etc/depmod.d/qla2xxx.conf","./etc/dracut.conf.d/qla2xxx.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/qlgc-qla2xxx","./lib/modules/4.18.0-240.el8.x86_64/extra/qlgc-qla2xxx/qla2xxx.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/qlgc-qla2xxx/tcm_qla2xxx.ko","./usr/share/smartupdate/kmod-qlgc-qla2xxx/component.xml"],"md5sum":"c9b0fdd3402f39b627187bccecb8f3e2","name":"kmod-qlgc-qla2xxx-10.02.01.00.a14_k1-1.rhel8u3.x86_64.rpm","release":"2021-09-23T00:00:00","revision":"1","sha1sum":"c3883cb51270babef7da3d59969d6a2943b89259","size":"5MB","target_guids":[],"type_of_change":"1","version":"10.02.01.00.a14-k1"}],"id":{"product":"790ca1788c9d4efc808a38c8331717bf","version":"477a18f0e845441b93c6690db29283d9"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-qlgc-qla2xxx-10.02.01.01.a2_k1-1.rhel8u4.x86_64.rpm<br />\n<br />\n4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;&nbsp;</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Red Hat Enterprise Linux 8 Update 3 Server Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters and Mezzanine Host Bus Adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015D","subven":"1077","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015C","subven":"1077","target_guid":"","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-10-30T11:08:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to driver version 10.02.01.00.a14-k1</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to driver version 10.02.01.00.a14-k1</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"kmod-qlgc-qla2xxx","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following storage controllers: Smart Array P230i, P430, P431, P731m, P830i, and P830"},{"lang":"cn","x_late":"该 Smart Component 可为以下存储控制器提供固件： 智能阵列 P230i、P430、P431、 P731m、P830i 和 P830"},{"lang":"tw","x_late":"此智慧型元件提供適用於下列儲存控制器的韌體： Smart Array P230i、P430、P431、P731m、P830i 及 P830"},{"lang":"ko","x_late":"이 스마트 구성 요소는 다음과 같은 스토리지 컨트롤러용 펌웨어를 제공합니다. 스마트 어레이 P230i, P430, P431, P731m, P830i, P830"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のストレージコントローラーのファームウェアを提供します。 SmartアレイP230i、P430、P431、P731m、P830i および P830"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Supplemental Update / Online ROM Flash Component for ESXi&nbsp;- Smart Array P230i,&nbsp;P430, P431, P731m, P830i, and P830</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;5.02(A)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;5.02<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;5.02<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp; &nbsp;&nbsp;Added support fro the ESXI OS7.0</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"22923663","datemodified":"2020-08-28T05:27:47","file_list":["/CP045345.vmexe","/CP045345.vmexe64","/CP045345.vmfile","/CP045345.xml","/payload.json","/README.txt"],"md5sum":"1246181ea75df164e87dc1ea7c8a9c4c","name":"CP045345.zip","release":"2020-08-28T05:15:05","revision":"0","sha1sum":"55be01a6ec914e38f762b8392ba947ca18719c96","size":"21MB","target_guids":[],"type_of_change":"1","version":"5.02","vib_list":[]}],"id":{"product":"fe91742b3a574fb18dfddbbd9fae74ba","version":"12a40ca3f52e478c8bb3262962e84383"},"installation":{"command":"CP045345.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActiveIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Smart Array HPCISSS3 Controller Driver version 100.18.2.64 must not be used for firmware update.  Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfd368f11","ServerModel":["*"],"Target_guids":[],"Type":"NE","Version":"100.18.2.64","description":"HPE ProLiant Smart Array HPCISSS3 Controller Driver version 100.18.2.64 must not be used for firmware update.  Update the driver and reboot before attempting firmware update."}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /hp/swpackages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at: <a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;<br />\n<strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Smart Component zip file in a temporary directory</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPXXXXXX.vmexe&nbsp; &nbsp;or&nbsp;chmod +x CPXXXXX.vmexe64 (for ESXi7.0)</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp;or ./CPXXXXX.vmexe64 (for ESXi7.0)</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware ESXi - Smart Array P230i, P430, P431, P731m, P830i, and P830"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"323c","subdev":"1924","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1921","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1926","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1923","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1922","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1928","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-24T10:45:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support for the ESXI OS7.0</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added support for the ESXI OS7.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"J06","value":"HP ProLiant MicroServer Gen8"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"P78","value":"HP ProLiant ML310e Gen8 v2 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"}],"sw_keys":[{"name":"1928103c","sw_key_expectedpath":"firmware"},{"name":"1923103c","sw_key_expectedpath":"firmware"},{"name":"1922103c","sw_key_expectedpath":"firmware"},{"name":"1924103c","sw_key_expectedpath":"firmware"},{"name":"1921103c","sw_key_expectedpath":"firmware"},{"name":"1926103c","sw_key_expectedpath":"firmware"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains iSCSI drivers for the HPE Emulex 10/20GbE Server Adapters running under Red Hat Enterprise Linux 7 x86_64."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7 x86_64で動作するHPE Emulex 10/20GbE サーバーアダプター用のiSCSIドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"953242","datemodified":"2021-01-14T07:50:15","file_list":["./etc/depmod.d/be2iscsi.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/be2iscsi","./lib/modules/3.10.0-1127.el7.x86_64/extra/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/kmod-be2iscsi/component.xml"],"md5sum":"6fa6a3fa29370b649c57c14326e6961a","name":"kmod-be2iscsi-12.0.1342.0-1.rhel7u8.x86_64.rpm","release":"2021-01-14T07:37:04","revision":"0","sha1sum":"034c8b07afcca0dc9fe2c1da7864a70ef57ebf44","size":"930KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd9057dd3"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"954112","datemodified":"2021-01-14T07:46:26","file_list":["./etc/depmod.d/be2iscsi.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/be2iscsi","./lib/modules/3.10.0-1160.el7.x86_64/extra/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/kmod-be2iscsi/component.xml"],"md5sum":"56b8c822abc0b5d74be445dd09575879","name":"kmod-be2iscsi-12.0.1342.0-1.rhel7u9.x86_64.rpm","release":"2021-01-14T07:37:04","revision":"0","sha1sum":"b839c4a4d0d30f77a18e2958db4c06c1d0cb90bd","size":"931KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd9057dd3"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"1120be85411a4c4091bc1cad7f1e1af8","version":"38a828dcb5944a6f820916bfd8f83aa9"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Emulex 10/20GbE iSCSI Drivers for Red Hat Enterprise Linux 7 x86_64"},{"lang":"ja","x_late":"HPE Emulex 10/20GbE iSCSIドライバー for Red Hat Enterprise Linux 7 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0728","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c8144","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c21d4","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072215908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c220a","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 7 Update 8 and&nbsp;Red Hat Enterprise Linux 7 Update 9</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"kmod-be2iscsi","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2iscsi","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2iscsi","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2iscsi","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWEBH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBUGD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a57454248","Version":"HPD5"},{"DeviceName":"EG000300JWEBF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBUGD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57454246","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models:EG000600JWEBH and EG000300JWEBF"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、ドライブモデル：EG000600JWEBHおよびEG000300JWEBFのファームウェアを提供します。"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG000600JWEBH and EG000300JWEBF Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5514636","datemodified":"2021-08-25T12:13:27","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-aa9e289524-HPD5-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-aa9e289524-HPD5-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-aa9e289524-HPD5-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-aa9e289524-HPD5-2.1/CP049347.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-aa9e289524-HPD5-2.1/STHBUGD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-aa9e289524-HPD5-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-aa9e289524-HPD5-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-aa9e289524-HPD5-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-aa9e289524-HPD5-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049347.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049347.scexe"],"md5sum":"5d1ac611ce46fc28ff461742ba040e81","name":"firmware-hdd-aa9e289524-HPD5-2.1.x86_64.rpm","release":"2021-08-25T11:59:05","revision":"0","sha1sum":"463fb3d71abf2c5ad7ffb0f68f49f5d68b57509f","size":"5MB","target_guids":["452340a5-3047-3030-3630-304a57454248","452340a5-3047-3030-3330-304a57454246"],"type_of_change":"1","version":"HPD5"}],"id":{"product":"9931ebb8026f40e8a799a9d593247da2","version":"b4a748a77b1547dbbbcde3d777743d85"},"installation":{"command":"CP040342.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64)  - EG000600JWEBH and EG000300JWEBF Drives"},{"lang":"ja","x_late":"オンラインHDD/SDDフラッシュコンポーネント for Linux (x64) - EG000600JWEBHおよびEG000300JWEBFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EG000300JWEBF","target_guid":"452340a5-3047-3030-3330-304a57454246","type":"sas"},{"id":"EG000600JWEBH","target_guid":"452340a5-3047-3030-3630-304a57454248","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-25T11:54:26","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG000600JWEBH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG000300JWEBF","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"VMware vSphere 6.5 Fibre Channel Driver kit for HPE Storage Emulex Host Bus Adapters(HBAs)"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1467974","datemodified":"2021-08-26T11:25:50","file_list":["/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip","/cp048603.xml","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/lpfc-12.8.317.0-1OEM.650.0.0.4598673.x86_64.vib","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/doc/README.txt","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/doc/release_note_lpfc_12.8.317.0-1OEM.650.0.0.4598673.txt","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/index.xml","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/vendor-index.xml","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/metadata.zip","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/vib20/lpfc/EMU_bootbank_lpfc_12.8.317.0-1OEM.650.0.0.4598673.vib","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/metadata.zip/vmware.xml","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-lpfc-12.8.317.0.xml","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/metadata.zip/vibs/lpfc--3610581689307200678.xml"],"md5sum":"bbdf7cf82a52efeb747efb1a7ac760d8","name":"cp048603.zip","release":"2021-08-26T11:25:05","revision":"0","sha1sum":"ada269ce500c800e52132ebaed0268cb43c49e11","size":"1MB","target_guids":[],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"lpfc","version":"12.8.317.0-1OEM.650.0.0.4598673"}]}],"id":{"product":"faebca12a56d421ea62a7cf35e1cd7d1","version":"1cc71dc3bb0045ffbe6ec72723ef252b"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware Vsphere Update Manager(VUM) or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on Vsphere Update Manager(VUM) and the esxcli commands</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Emulex Fibre Channel driver component for VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"F100","subven":"10DF","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T10:36:04","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>Added the following:-</strong></p>\n\n<ul>\n\t<li>Changed the default Logical Unit Number (LUN) queue depth from 30 to 64</li>\n\t<li>Added Non-volatile memory express (NVMe) over Fibre Channel (FC) capability</li>\n</ul>\n\n<p>Updated to Driver version 12.8.317.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"lpfc:12.8.317.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO0480JFDGT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304f-3438-304a46444754","Version":"HPD9"},{"DeviceName":"VO0960JFDGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304f-3936-304a46444755","Version":"HPD9"},{"DeviceName":"VO1920JFDGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314f-3932-304a46444756","Version":"HPD9"},{"DeviceName":"VO3840JFDHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-334f-3834-304a46444841","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VO0480JFDGT, VO0960JFDGU, VO1920JFDGV and VO3840JFDHA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VO0480JFDGT, VO0960JFDGU, VO1920JFDGV and VO3840JFDHA Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD9</p>\n\n<p><strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD8</p>\n\n<p><strong>Previous Version of Firmware:<br />\n&nbsp; &nbsp; &nbsp;</strong> HPD8</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"16601682","datemodified":"2021-08-27T12:35:52","file_list":["/CP048437_BUILD_3.data","/CP048437.vmexe","/CP048437.vmexe64","/CP048437.vmfile","/CP048437_VMw.zip","/CP048437.xml","/payload.json","/CP048437_VMw.zip/index.xml","/CP048437_VMw.zip/vendor-index.xml","/CP048437_VMw.zip/metadata.zip","/CP048437_VMw.zip/vib20/CP048437/HPE_bootbank_CP048437_HPD9.3-7.0.0.15843807.vib","/CP048437_VMw.zip/metadata.zip/vendor-index.xml","/CP048437_VMw.zip/metadata.zip/vmware.xml","/CP048437_VMw.zip/metadata.zip/vibs/CP048437-474269553684214630.xml","/CP048437_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048437_HPD9.3-7.0.0.15843807.xml"],"md5sum":"18a7f3e5959f7a4c8b867491b1c8c4b9","name":"CP048437.zip","release":"2021-08-27T12:30:51","revision":"0","sha1sum":"b9ae827729eb3d24e5528cd7252049c467b28b6b","size":"15MB","target_guids":["002340a5-5600-304f-3438-304a46444754","002340a5-5600-304f-3936-304a46444755","002340a5-5600-314f-3932-304a46444756","002340a5-5600-334f-3834-304a46444841"],"type_of_change":"1","version":"HPD9","vib_list":[{"name":"CP048437","version":"HPD9.3-7.0.0.15843807"}]}],"id":{"product":"6b5a27285d114b399ac0db53bb209710","version":"8cd5c14d0d644d97a05775f03fc304f7"},"installation":{"command":"CP042219.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします。</li>\n\t<li>CPXXXXXX.vmexe(ESXi 6.7 &以前のバージョン)およびCPXXXXXX.vmexe64(ESXi 7.0)は、次のコマンドを使用して実行可能です:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod x CPXXXXXX.vmexe    または    chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPXXXXXX.vmexe(または)./CPXXXXXX.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VO0480JFDGT, VO0960JFDGU, VO1920JFDGV and VO3840JFDHA Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VO0480JFDGT、VO0960JFDGU、VO1920JFDGV、およびVO3840JFDHAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VO3840JFDHA","target_guid":"002340a5-5600-334f-3834-304a46444841","type":"sas"},{"id":"VO1920JFDGV","target_guid":"002340a5-5600-314f-3932-304a46444756","type":"sas"},{"id":"VO0960JFDGU","target_guid":"002340a5-5600-304f-3936-304a46444755","type":"sas"},{"id":"VO0480JFDGT","target_guid":"002340a5-5600-304f-3438-304a46444754","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-10T11:13:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO0960JFDGU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO0480JFDGT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO3840JFDHA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO1920JFDGV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Intel igbn Adapters running under VMware vSphere 6.5."},{"lang":"ja","x_late":"この製品は、VMware vSphere 6.5.上で動作するHPE Intel igbnアダプターのためのドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;1.5.2.0.</p>\n"}],"files":[{"bytes":"125593","datemodified":"2021-01-08T22:10:28","file_list":["/cp042677.xml","/VMW-ESX-6.5.0-igbn-1.5.2.0-offline_bundle-17300361.zip","/VMW-ESX-6.5.0-igbn-1.5.2.0-offline_bundle-17300361.zip/index.xml","/VMW-ESX-6.5.0-igbn-1.5.2.0-offline_bundle-17300361.zip/vendor-index.xml","/VMW-ESX-6.5.0-igbn-1.5.2.0-offline_bundle-17300361.zip/metadata.zip","/VMW-ESX-6.5.0-igbn-1.5.2.0-offline_bundle-17300361.zip/vib20/igbn/INT_bootbank_igbn_1.5.2.0-1OEM.650.0.0.4598673.vib","/VMW-ESX-6.5.0-igbn-1.5.2.0-offline_bundle-17300361.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.5.0-igbn-1.5.2.0-offline_bundle-17300361.zip/metadata.zip/vmware.xml","/VMW-ESX-6.5.0-igbn-1.5.2.0-offline_bundle-17300361.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-igbn-1.5.2.0.xml","/VMW-ESX-6.5.0-igbn-1.5.2.0-offline_bundle-17300361.zip/metadata.zip/vibs/igbn--38488993777072084.xml"],"md5sum":"392903c515cef277062e821c02ce9dd5","name":"cp042677.zip","release":"2021-01-08T22:09:04","revision":"0","sha1sum":"86de4401455fa23777d2a72172fb67eb097f1689","size":"122KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55"],"type_of_change":"0","version":"2021.04.05","vib_list":[{"name":"igbn","version":"1.5.2.0-1OEM.650.0.0.4598673"}]}],"id":{"product":"875c48447044433ba822fd2b79f25cb2","version":"2e44b0418d0c49cf909bbec08868dbf0"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel igbn Driver for VMware vSphere 6.5"},{"lang":"ja","x_late":"HPE Intel igbnドライバーfor VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"1523","subdev":"1989","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1523103c1989","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00FF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1521159000ff","type":"pci","ven":"8086"},{"dev":"1521","subdev":"337F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c337f","type":"pci","ven":"8086"},{"dev":"1521","subdev":"3380","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-1521103c3380","type":"pci","ven":"8086"},{"dev":"1521","subdev":"339E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c339e","type":"pci","ven":"8086"},{"dev":"1521","subdev":"17D1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c17d1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"8157","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c8157","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now remove&nbsp;supports Synergy and Blade&nbsp;Server.</p>\n","latest_fixes_x_late":"<p>This product addresses an issue where race condition during NIC adapter reset.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product corrects an issue which handling duplex value passed of ESXi command.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"igbn:1.5.2.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]},{"key":"7800374","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"en","x_late":"This package contains the kit to provide support for Smart SAN on QLogic fibre channel host bus adapters on Linux operating systems."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"18574","datemodified":"2021-08-27T04:31:12","file_list":["./opt/hpe/ql_smartsan/ql_ss_enablement","./opt/hpe/ql_smartsan/qlssen.sh","./opt/hpe/ql_smartsan/qlssen.txt","./usr/share/smartupdate/hpe-qlogic-smartsan-enablement-kit/component.xml"],"md5sum":"5eaa7f0de257a6f4e287bc82b9e79abe","name":"hpe-qlogic-smartsan-enablement-kit-3.3-3.x86_64.rpm","release":"2021-08-27T04:27:35","revision":"0","sha1sum":"2f47543a6c5bae0305d6c946de2e01d58eea2021","size":"18KB","target_guids":[],"type_of_change":"0","version":"3.3-3"}],"id":{"product":"736cc31c6408479e9fd7c644b04a1c98","version":"56b3470559614823868a7652313ebc75"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>SmartSAN is a 64 bit&nbsp;specific kit.&nbsp;It is recommended that you uninstall any previous kits prior to installation of this component.</p>\n\n<p style=\"margin-left:40px\">To uninstall the QLogic Smart SAN enablement RPM use the following command:</p>\n\n<p style=\"margin-left:40px\"># rpm -e hpe-qlogic-smartsan-enablement-&lt;version&gt;.noarch.rpm</p>\n\n<p>This is a configurable component.&nbsp; It requires a configuration file in order to enable/disable Smart SAN functionality.&nbsp; If no configuration is performed, the current Smart SAN status is stated and the execution is complete.&nbsp; No further action is taken.</p>\n\n<p>&nbsp;</p>\n\n<p>For detailed information about configurable components, see the&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00106063en_us\"><em>Smart Update Manager User Guide </em></a></p>\n\n<p>&nbsp;</p>\n\n<p><strong>Component execution outside of HPE Service Pack for Proliant</strong>:</p>\n\n<p style=\"margin-left:40px\">1.&nbsp;Login as the system administrator (root).</p>\n\n<p style=\"margin-left:40px\">2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p style=\"margin-left:40px\">3.&nbsp;To install, type the following command at the prompt:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -ivh hpe-qlogic-smartsan-enablement-kit-&lt;version&gt;.x86_64.rpm<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -ivh hpe-qlogic-smartsan-enablement-kit-3.3-3.x86_64.rpm</p>\n\n<p style=\"margin-left:40px\">4.&nbsp;When the installation or upgrade is complete, the following message displays:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Installation complete</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic Smart SAN enablement kit for Linux"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015D","subven":"1077","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015C","subven":"1077","target_guid":"","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-18T06:27:22","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to version 3.3-3</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"hpe-qlogic-smartsan-enablement-kit","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001920KWVMT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1723b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304b57564d54","Version":"HPK3"},{"DeviceName":"VO003840KWVMU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1723b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304b57564d55","Version":"HPK3"},{"DeviceName":"VO007680KWVMV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1723b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304b57564d56","Version":"HPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO001920KWVMT, VO003840KWVMU and VO007680KWVMV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for Linux (x64) - VO001920KWVMT, VO003840KWVMU and VO007680KWVMV Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None.</p>\n"}],"files":[{"bytes":"7219008","datemodified":"2021-07-25T12:29:29","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-fe9c474847-HPK3-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-fe9c474847-HPK3-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-fe9c474847-HPK3-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-fe9c474847-HPK3-3.1/CP048239.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-fe9c474847-HPK3-3.1/GP1723b0HPK3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-fe9c474847-HPK3-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-fe9c474847-HPK3-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-fe9c474847-HPK3-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-fe9c474847-HPK3-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048239.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048239.scexe"],"md5sum":"ddf0f171f4e3b82e7e02c40559261d6d","name":"firmware-hdd-fe9c474847-HPK3-3.1.x86_64.rpm","release":"2021-07-25T12:17:04","revision":"0","sha1sum":"a282cef4a6e3511a945e8b3f67f66c46c41c0ce5","size":"6MB","target_guids":["562340a5-304f-3130-3932-304b57564d54","562340a5-304f-3330-3834-304b57564d55","562340a5-304f-3730-3638-304b57564d56"],"type_of_change":"1","version":"HPK3"}],"id":{"product":"5bfad4d210f242bd90a5c8fa29d29f05","version":"9c5eb08b32f146a09e335f590c9c98b2"},"installation":{"command":"CP041314.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left: 30pt;\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left: 30pt;\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - VO001920KWVMT, VO003840KWVMU, and VO007680KWVMV Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - VO001920KWVMT、VO003840KWVMU、およびVO007680KWVMVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VO007680KWVMV","target_guid":"562340a5-304f-3730-3638-304b57564d56","type":"nvme"},{"id":"VO003840KWVMU","target_guid":"562340a5-304f-3330-3834-304b57564d55","type":"nvme"},{"id":"VO001920KWVMT","target_guid":"562340a5-304f-3130-3932-304b57564d54","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-01T09:03:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Fixed SSD weargauge report error issue.</li>\n\t<li>Fixed Assign FWState as TR_DONE_ERR at the correct location.</li>\n\t<li>Prepare proper response data for Get Message Type Supported MCTP Command.</li>\n\t<li>Added code to preserve current feature values cross live firmware update.</li>\n\t<li>Allocate 4 bytes instead of 2 bytes for parameter code.</li>\n\t<li>Changed the value for NLB equal to NSize -1.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO007680KWVMV","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO003840KWVMU","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO001920KWVMT","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Intel ixt 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2016."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Microsoft Windows Server 2016で動作しているHPE Intel ixt 10 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1156528","datemodified":"2021-01-08T19:47:32","file_list":["cp045118.xml","cpqsetup.exe","cp_data.xml","install.xml","ixt65x64.cat","ixt65x64.din","ixt65x64.inf","ixt65x64.sys","ixtmsg.dll","NicCo5.dll","nicdrvr.dll","NicInIXT.dll"],"md5sum":"2d7d282a390670a4cc16e8258037a2bf","name":"cp045118.exe","release":"2021-01-08T19:32:08","revision":"0","sha1sum":"eb2526c07712428a365019705918c69c0c5be028","size":"1MB","target_guids":[],"type_of_change":"0","version":"4.1.199.0"}],"id":{"product":"a8417355844c4be0a58d7ebc978d6631","version":"2a4abf5d38e94e11958e9959e1668384"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel ixt Driver for Windows Server 2016"},{"lang":"ja","x_late":"HPE Intel ixtドライバー for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product has been built with a new installer that prevents its installation on systems running Windows Server 2019.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p style=\"margin-left:0px; margin-right:0px\">This product now supports the following network adapters:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>HPE Ethernet 10Gb 2-port 561FLR-T Adapter</li>\n\t<li>HPE Ethernet 10Gb 2-port 561T Adapter</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"}],"sw_keys":[{"name":"ixt65x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000150GWCNN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3135-304757434e4e","Version":"HPG1"},{"DeviceName":"VK000240GWCNP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757434e50","Version":"HPG1"},{"DeviceName":"VK000480GWCNQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757434e51","Version":"HPG1"},{"DeviceName":"VK000960GWCNR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757434e52","Version":"HPG1"},{"DeviceName":"VK001600GWCNT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3630-304757434e54","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK000150GWCNN, VK000240GWCNP, VK000480GWCNQ, VK000960GWCNR and VK001600GWCNT"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：VK000150GWCNN、VK000240GWCNP、VK000480GWCNQ、VK000960GWCNR および VK001600GWCNT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for&nbsp;Windows (x64)&nbsp;- VK000150GWCNN, VK000240GWCNP, VK000480GWCNQ, VK000960GWCNR and VK001600GWCNT Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"2834680","datemodified":"2021-07-22T11:38:01","file_list":["4IDVHPG1.rel","cp048635.xml","cpqsetup.exe","payload.json","setup.dll"],"md5sum":"eec88631f0135bcaa8e4a7aa4320241c","name":"cp048635.exe","release":"2021-07-22T11:29:07","revision":"0","sha1sum":"08e31ea5299d421250d9235412e0a3cbc7e20d71","size":"2MB","target_guids":["562340a5-304b-3030-3135-304757434e4e","562340a5-304b-3030-3234-304757434e50","562340a5-304b-3030-3438-304757434e51","562340a5-304b-3030-3936-304757434e52","562340a5-304b-3130-3630-304757434e54"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"ea55ec7473304ea29dd406dfd2137028","version":"70ccb44535494a9684a969c153cc001f"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK000150GWCNN, VK000240GWCNP, VK000480GWCNQ, VK000960GWCNR and VK001600GWCNT Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - VK000150GWCNN、VK000240GWCNP、VK000480GWCNQ、VK000960GWCNR、およびVK001600GWCNTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VK001600GWCNT","target_guid":"562340a5-304b-3130-3630-304757434e54","type":"sata"},{"id":"VK000960GWCNR","target_guid":"562340a5-304b-3030-3936-304757434e52","type":"sata"},{"id":"VK000480GWCNQ","target_guid":"562340a5-304b-3030-3438-304757434e51","type":"sata"},{"id":"VK000240GWCNP","target_guid":"562340a5-304b-3030-3234-304757434e50","type":"sata"},{"id":"VK000150GWCNN","target_guid":"562340a5-304b-3030-3135-304757434e4e","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T14:58:13","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK000480GWCNQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000150GWCNN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001600GWCNT","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWCNR","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWCNP","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This package updates the I/O module firmware on HPE D6020 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"4004583","datemodified":"2021-06-22T11:09:43","file_list":["./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-10.1","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-10.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-10.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-10.1/CP048698.xml","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-10.1/Config.xml","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-10.1/Tormore-Release-2.74-build-001.bin","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-10.1/ccissflash","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-10.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-10.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-10.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048698.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048698.scexe"],"md5sum":"595c7d11c136cb8438ed66a3559963b7","name":"firmware-d6020-2.74-10.1.x86_64.rpm","release":"2021-06-22T10:59:05","revision":"0","sha1sum":"47de24e5d3ab0f90fa48c20521407e323656407d","size":"3MB","target_guids":[],"type_of_change":"1","version":"2.74"}],"id":{"product":"bbceec42cb6340498d7a9820eeba186d","version":"43540ee82fa24399a5cc8570c92999b1"},"installation":{"command":"setup","command_params":"-t D6020 -v 2.74 -i Tormore-Release-2.74-build-001.bin -l D6020.log","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":720,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Linux Smart Component Installation Instructions:</strong></p>\n\n<p><strong>Updating firmware with rpm installation:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The&nbsp;CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-d6020-&lt;version&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:&nbsp;</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-d6020-&lt;version&gt;-*&#39; location</p>\n\n<ul>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p><strong>NOTES:</strong></p>\n\n<p>OPTIONS for in band enclosure flash</p>\n\n<table border=\"0\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>-d,&nbsp;--discover &lt;absolute path to file&gt;</td>\n\t\t\t<td>Dumps discovery information in XML format to &lt;file&gt;</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-e,&nbsp;--reflash</td>\n\t\t\t<td>Flash even if the device is already up to date</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-f,&nbsp; --force</td>\n\t\t\t<td>Always flash applicable devices (same as -e -g)</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-g,&nbsp;--downgrade</td>\n\t\t\t<td>Flash if the device has a later firmware</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-s,&nbsp;--silent</td>\n\t\t\t<td>Do not display any text and no user interaction required</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li>\n\t<li>Place the SPP on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\"><u>USB Key Creator Utility</u></a>.</li>\n\t<li>Boot from the newly created&nbsp; Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root (You must be root in order to apply the ROM update).</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li>\n\t<li>Run the launch_sum.sh in the root of the ISO.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v191364/D6020_v2.74I.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component for Linux (x64)"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"id":"D6020","target_guid":"","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-17T13:15:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p>\n\n<ul>\n\t<li>Temperature sensors logic inside gSEP model and SES database</li>\n\t<li>When an IOM is pulled the surviving IOM reports false critical temperatures</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v191364/D6020_v2.74I.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"}],"sw_keys":[{"name":"D6020","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000800JWZJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3830-304a575a4a50","Version":"HPD4"},{"DeviceName":"VO001600JWZJQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3630-304a575a4a51","Version":"HPD4"},{"DeviceName":"VO003200JWZJR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3230-304a575a4a52","Version":"HPD4"},{"DeviceName":"VO006400JWZJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3630-3430-304a575a4a54","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO000800JWZJP、VO001600JWZJQ、VO003200JWZJRおよびVO006400JWZJT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp;&nbsp; </strong>None</p>\n"}],"files":[{"bytes":"5038788","datemodified":"2021-07-23T10:22:49","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD4-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD4-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD4-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD4-2.1/CP048217.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD4-2.1/GPM1645ASAD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD4-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD4-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD4-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD4-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048217.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048217.scexe"],"md5sum":"b11d41ab19b6c4ffe22f9cb07b04459e","name":"firmware-hdd-a07a420ed1-HPD4-2.1.x86_64.rpm","release":"2021-07-23T10:11:06","revision":"0","sha1sum":"cfa8115453b11006dd2e6c7bc4ec88ab128ba184","size":"4MB","target_guids":["562340a5-304f-3030-3830-304a575a4a50","562340a5-304f-3130-3630-304a575a4a51","562340a5-304f-3330-3230-304a575a4a52","562340a5-304f-3630-3430-304a575a4a54"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"f12cb892007944f694736d03ec00543c","version":"b21d6124bcd04af3b5df7dee43d49cc1"},"installation":{"command":"CP040349.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://www.hp.com/swpublishing/MTX-357c87ee9b054ad7a631d9eaba\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VO000800JWZJP、VO001600JWZJQ、VO003200JWZJRおよびVO006400JWZJTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VO006400JWZJT","target_guid":"562340a5-304f-3630-3430-304a575a4a54","type":"sas"},{"id":"VO003200JWZJR","target_guid":"562340a5-304f-3330-3230-304a575a4a52","type":"sas"},{"id":"VO001600JWZJQ","target_guid":"562340a5-304f-3130-3630-304a575a4a51","type":"sas"},{"id":"VO000800JWZJP","target_guid":"562340a5-304f-3030-3830-304a575a4a50","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T12:37:09","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Modify Drive Vendor Identification String (VID) in Inquiry page from &ldquo;HP&rdquo; to &ldquo;HPE&rdquo;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO000800JWZJP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003200JWZJR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001600JWZJQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO006400JWZJT","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the iSCSI driver for the HPE Emulex 10/20Gb Server Adapters for Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Windows Server 2019用のHPE Emulex 10/20GbサーバーアダプターのiSCSIドライバー を含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"906528","datemodified":"2020-06-12T10:45:28","file_list":["be2iscsi.cat","be2iscsi.inf","be2iscsi.sys","bepiscsi.dll","cp044562.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"md5sum":"49c6fa5346af463c999d04a805a12340","name":"cp044562.exe","release":"2020-06-12T10:32:05","revision":"0","sha1sum":"ace4876a411ff30399c36a4f9bb4bb25e919a870","size":"885KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec037c8524"],"type_of_change":"0","version":"12.0.1171.0"}],"id":{"product":"14ccfdf7a8d64255bce75290d1e21746","version":"299f3ac601a4460d9602ffd6fac4d9d8"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex 10/20 GbE iSCSI Driver for Windows Server 2019"},{"lang":"ja","x_late":"HPE Emulex 10/20 GbE iSCSIドライバー for Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"320"},"supported_devices":[{"dev":"0722","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c220a","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c21d4","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c8144","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072215908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-12T06:00:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now remove&nbsp;supports Synergy and Blade&nbsp;Server.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p style=\"text-align:left\">This product now supports the following network adapters:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"be2iscsi.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900374","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware and boot BIOS of Emulex Mezzanine Fibre Channel Host Bus Adapters."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11242580","datemodified":"2021-08-31T08:27:46","file_list":["./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-emulex-2021.10.01-1.5","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-emulex-2021.10.01-1.5/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-emulex-2021.10.01-1.5/.setup","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-emulex-2021.10.01-1.5/CP048579.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-emulex-2021.10.01-1.5/elxflashStandalone-linux-12.8.528.12-1.zip","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-emulex-2021.10.01-1.5/firmware","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-emulex-2021.10.01-1.5/firmware/A12852812.grp","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-emulex-2021.10.01-1.5/fwmatrix.txt","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-emulex-2021.10.01-1.5/hpe_fw_matrix.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-emulex-2021.10.01-1.5/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-emulex-2021.10.01-1.5/payload.json","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-emulex-2021.10.01-1.5/readme.txt","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-emulex-2021.10.01-1.5/reference.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-emulex-2021.10.01-1.5/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048579.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048579.scexe"],"md5sum":"eafd32e3405ddc35e9c7b29c0c0f8158","name":"firmware-fc-mezz-emulex-2021.10.01-1.5.x86_64.rpm","release":"2021-08-31T08:15:40","revision":"0","sha1sum":"c41240650a8fb8ebcc1f3c0484e0692317fb80c8","size":"10MB","target_guids":[],"type_of_change":"1","version":"2021.10.01"}],"id":{"product":"13b4e3ebe6e74db48f679627b171e06a","version":"bca83ef409ce411ba34d5d75f77a0bbb"},"installation":{"command":"installer","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Firmware installation is a two-step process.&nbsp; Install the firmware installation tool rpm, then execute the installed tool to update the firmware.<br />\n&nbsp;<br />\n&nbsp;1. Install the firmware installation tool:&nbsp; rpm -Uvh &lt;rpm_package_name&gt;.rpm&nbsp; This extracts the firmware installation tool to /usr/lib/x86_64-linux-gnu (64-bit systems) .<br />\n&nbsp;<br />\n&nbsp;2. cd to the appropriate location for your system, and update the firmware by executing ./setup<br />\n&nbsp;<br />\n&nbsp;When the firmware installation completes, you may remove the firmware installation tool from your system using the rpm -e command : rpm -e &lt;rpm_package_name&gt;.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Mezzanine Fibre Channel Host Bus Adapters for Linux (x64)"}],"prerequisites":{"required_diskspace":{"size_kb":"20000"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T09:15:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This Firmware package contains following firmware versions:&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 16Gb LPe1605 Fibre Channel Host Bus Adapter for BladeSystem c-Class</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>12.8.528.12</td>\n\t\t\t<td>12.8.528.12</td>\n\t\t\t<td>12.8.528.10</td>\n\t\t\t<td>12.8.502.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"emulex","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"9300211","languages":[{"lang":"fr","x_late":"Utilitaire - Outils"},{"lang":"en","x_late":"Utility - Tools"},{"lang":"cn","x_late":"实用程序 - 工具"},{"lang":"tw","x_late":"公用程式 ─ 工具"},{"lang":"de","x_late":"Hilfsprogramm - Tools"},{"lang":"ko","x_late":"유틸리티 – 도구"},{"lang":"it","x_late":"Utility - Strumenti"},{"lang":"ja","x_late":"ユーティリティ - ツール"},{"lang":"es","x_late":"Utilidad - Herramientas"}]}],"description":[{"lang":"en","x_late":"This product includes HPONCFG, BOOTCFG, TESTEVENT, CONREP, and the Smart Storage Array Command Line Interface (SSACLI) utilities for configuration of servers. HPONCFG can be used to set up and reconfigure the iLO (Integrated Lights-Out) management controller of a server. BOOTCFG can be used to set up the boot configuration for the server. SSACLI can be used in the configuration of HPE Smart Array controllers and attached storage. The TESTEVENT utility generates test WBEM indication and test SNMP trap. The CONREP Utility enables server hardware configuration capture, set and duplication. "},{"lang":"ja","x_late":"この製品には、HPONCFG、BOOTCFG、TESTEVENT、CONREP、およびサーバーを構成するためのSmart Storage Array Command Line Interface (SSACLI)ユーティリティーが含まれています。HPONCFGは、サーバーのiLO(Integrated Lights-Out)マネジメントコントローラーの設定、再構成に使用できます。BOOTCFGはサーバーの起動構成を設定するために使用できます。SSACLIは、HPE Smartアレイコントローラーと接続されたストレージの構成に使用できます。TESTEVENTユーティリティはテストWBEMイベントとテストSNMPトラップを作ります。CONREPユーティリティは、サーバーハードウェア構成のキャプチャー、設定、そして複製を可能にします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11015223","datemodified":"2021-09-14T14:30:01","file_list":["/cp047458.xml","/HPE-Utility-Component_10.8.0.650-26.zip","/HPE-Utility-Component_10.8.0.650-26.zip/index.xml","/HPE-Utility-Component_10.8.0.650-26.zip/vendor-index.xml","/HPE-Utility-Component_10.8.0.650-26.zip/metadata-HPE-Utility-Component_10.8.0.650-26.zip","/HPE-Utility-Component_10.8.0.650-26.zip/hponcfg-6.0.0.5.5-0.37.2494585.vib","/HPE-Utility-Component_10.8.0.650-26.zip/bootcfg-6.0.0.02-06.00.16.2494585.vib","/HPE-Utility-Component_10.8.0.650-26.zip/conrep_650.10.8.0.12-6.5.0.2494585.vib","/HPE-Utility-Component_10.8.0.650-26.zip/cru_650.6.5.10.4-1OEM.650.0.0.4240417.vib","/HPE-Utility-Component_10.8.0.650-26.zip/MIS_bootbank_hpessacli_5.20.8.0-6.5.0.4240417.oem.vib","/HPE-Utility-Component_10.8.0.650-26.zip/ilo_650.10.7.5.2-1OEM.650.0.0.4240417.vib","/HPE-Utility-Component_10.8.0.650-26.zip/testevent-6.5.0.02-01.00.9.4240417.vib","/HPE-Utility-Component_10.8.0.650-26.zip/metadata-HPE-Utility-Component_10.8.0.650-26.zip/vendor-index.xml","/HPE-Utility-Component_10.8.0.650-26.zip/metadata-HPE-Utility-Component_10.8.0.650-26.zip/vmware.xml","/HPE-Utility-Component_10.8.0.650-26.zip/metadata-HPE-Utility-Component_10.8.0.650-26.zip/vibs/hponcfg-1881737420209856034.xml","/HPE-Utility-Component_10.8.0.650-26.zip/metadata-HPE-Utility-Component_10.8.0.650-26.zip/vibs/bootcfg-1749855250648854147.xml","/HPE-Utility-Component_10.8.0.650-26.zip/metadata-HPE-Utility-Component_10.8.0.650-26.zip/vibs/conrep-6078124524435142414.xml","/HPE-Utility-Component_10.8.0.650-26.zip/metadata-HPE-Utility-Component_10.8.0.650-26.zip/vibs/cru-6087260586819000143.xml","/HPE-Utility-Component_10.8.0.650-26.zip/metadata-HPE-Utility-Component_10.8.0.650-26.zip/vibs/hpessacli--6978747662280214123.xml","/HPE-Utility-Component_10.8.0.650-26.zip/metadata-HPE-Utility-Component_10.8.0.650-26.zip/vibs/ilo-5995240362405261046.xml","/HPE-Utility-Component_10.8.0.650-26.zip/metadata-HPE-Utility-Component_10.8.0.650-26.zip/vibs/testevent--766157199079035683.xml","/HPE-Utility-Component_10.8.0.650-26.zip/metadata-HPE-Utility-Component_10.8.0.650-26.zip/bulletins/esxi6.5-util-bundle-10.8.0.650-26.xml"],"md5sum":"ed1fe91460510ad2e179452f325a31dd","name":"cp047458.zip","release":"2021-09-14T14:26:00","revision":"0","sha1sum":"87f55c6b50c8d015312a264db36731c664053d63","size":"10MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccecbdbe8","20a6e8e4-bf33-4c71-a6bf-d9ec8013c1b6","20a6e8e4-bf33-4c71-a6bf-d9ec0e2e459f","20a6e8e4-bf33-4c71-a6bf-d9ec23d0c2b9","20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","20a6e8e4-bf33-4c71-a6bf-d9ecf25c12c9"],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"hponcfg","version":"6.0.0.5.5-0.37.2494585"},{"name":"bootcfg","version":"6.0.0.02-06.00.16.2494585"},{"name":"conrep","version":"650.10.8.0.12-6.5.0.2494585"},{"name":"cru","version":"650.6.5.10.4-1OEM.650.0.0.4240417"},{"name":"hpessacli","version":"5.20.8.0-6.5.0.4240417.oem"},{"name":"ilo","version":"650.10.7.5.2-1OEM.650.0.0.4240417"},{"name":"testevent","version":"6.5.0.02-01.00.9.4240417"}]}],"id":{"product":"161a304825cb434e83dc121e59667140","version":"41bcb5f2ec354514944f52681eb61152"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To&nbsp;remotely install&nbsp;this&nbsp;bundle&nbsp; online using the HP Smart Update Manager (HPSUM) from the HP Service Pack for ProLiant (SPP):</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"http://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=8788688&amp;lang=en&amp;cc=us\">HP USB Key Creator Utility</a>.</li>\n\t<li>Copy&nbsp;this component&nbsp;to the directory<em> /SPP20xxxxx/hp/swpackages</em> on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.</li>\n\t<li>Change directories to <em>/hp/swpackages</em> and execute&nbsp;./hpsum.</li>\n\t<li>Select the &quot;next&quot; button.</li>\n\t<li>Click &quot;Add Single Target.&quot;</li>\n\t<li>Enter&nbsp;the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow HP Smart Update Manager&nbsp;instructions&nbsp;to complete the update.</li>\n</ol>\n\n<p><br />\n<strong>To&nbsp;install this bundle using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the component zip file to extract the offline bundle.</li>\n\t<li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li>\n</ol>\n\n<p>Refer to VMware documentation for information on the esxcli commands</p>\n"},{"lang":"ja","x_late":"<p><strong>HP Service Pack for ProLiant (SPP)からHP Smart Update Manager (HPSUM)を使用して、このバンドルをオンラインでリモートインストールするには：</strong></p>\n\n<ol>\n\t<li><a href=\"http://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=8788688&lang=en&cc=us\">HP USB Key Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>このコンポーネントをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。</li>\n\t<li><em>/hp/swpackages</em>にディレクトリを変更し、./hpsumを実行します。</li>\n\t<li>「次へ」ボタンを選択します。</li>\n\t<li>「シングルターゲットの追加」をクリックします。</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>HP Smart Update Managerの手順に従って、アップデートを完了します。</li>\n</ol>\n\n<p><br />\n<strong>VMwareツールを使用して、このバンドルをインストールするには：</strong></p>\n\n<ol>\n\t<li>オフラインバンドルを抽出するために、このコンポーネントのzipファイルを解凍します。</li>\n\t<li>オフラインバンドルをインストールするには、「esxcli」コマンドを実行します。</li>\n</ol>\n\n<p>esxcliコマンドの詳細については、VMwareのドキュメントを参照してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Utilities Bundle Smart Component for ESXi 6.5 "},{"lang":"ja","x_late":"HPE ユーティリティ バンドルSmartコンポーネント for ESXi 6.5 "}],"prerequisites":{"required_diskspace":{"size_kb":"100"},"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-01T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Includes an updated the Smart Storage Administrator CLI&nbsp;(SSACLI).</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>hpessacli</p>\n\n<ul>\n\t<li>Added initial passive SED support.</li>\n\t<li>Added new &quot;unchanged&quot; Drive Write Cache (DWC) policy to the applications.</li>\n\t<li>Added support for discovering and reporting failed drives that are not part of a RAID volume.</li>\n</ul>\n","curr_fixes_x_late":"<p>hpessacli</p>\n\n<ul>\n\t<li>Fixed an issue where the &quot;Turn off&quot; LED operation momentarily turns on all Identify LED.</li>\n\t<li>Fixed an issue where an NVME drive was failed after flashing drive firmware.</li>\n\t<li>Fixed an issue where an operation failure message was observed while deleting a volume with status &ldquo;Not Available&rdquo;.</li>\n\t<li>Fixed an issue that SSAScripting reported incorrect size for some drives greater than 1TB. This did not affect SSACLI.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"hponcfg:6.0.0.5.5-0.37.2494585","sw_key_expectedpath":"software:vmware:zip"},{"name":"testevent:6.5.0.02-01.00.9.4240417","sw_key_expectedpath":"software:vmware:zip"},{"name":"conrep:650.10.8.0.12-6.5.0.2494585","sw_key_expectedpath":"software:vmware:zip"},{"name":"hpessacli:5.20.8.0-6.5.0.4240417.oem","sw_key_expectedpath":"software:vmware:zip"},{"name":"ilo:650.10.7.5.2-1OEM.650.0.0.4240417","sw_key_expectedpath":"driver:vmware:zip"},{"name":"cru:650.6.5.10.4-1OEM.650.0.0.4240417","sw_key_expectedpath":"driver:vmware:zip"},{"name":"bootcfg:6.0.0.02-06.00.16.2494585","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the NIC and RoCE drivers for HPE Broadcom NetXtreme-E devices running under VMware vSphere 6.5."},{"lang":"ja","x_late":"この製品は、VMware vSphere 6.5下で動作するHPE Broadcom NetXtreme-Eデバイス用のNICおよびRoCEドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains NIC driver version&nbsp;218.0.38.0 and RoCE driver version&nbsp;218.0.16.0.</p>\n"}],"files":[{"bytes":"342007","datemodified":"2021-01-14T06:17:23","file_list":["/cp045073.xml","/VMW-ESX-6.5.0-bnxt-218.0-1-4564106-offline_bundle-17360326.zip","/VMW-ESX-6.5.0-bnxt-218.0-1-4564106-offline_bundle-17360326.zip/index.xml","/VMW-ESX-6.5.0-bnxt-218.0-1-4564106-offline_bundle-17360326.zip/vendor-index.xml","/VMW-ESX-6.5.0-bnxt-218.0-1-4564106-offline_bundle-17360326.zip/metadata.zip","/VMW-ESX-6.5.0-bnxt-218.0-1-4564106-offline_bundle-17360326.zip/vib20/bnxtnet/BCM_bootbank_bnxtnet_218.0.38.0-1OEM.650.0.0.4598673.vib","/VMW-ESX-6.5.0-bnxt-218.0-1-4564106-offline_bundle-17360326.zip/vib20/bnxtroce/BCM_bootbank_bnxtroce_218.0.16.0-1OEM.650.0.0.4598673.vib","/VMW-ESX-6.5.0-bnxt-218.0-1-4564106-offline_bundle-17360326.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.5.0-bnxt-218.0-1-4564106-offline_bundle-17360326.zip/metadata.zip/vmware.xml","/VMW-ESX-6.5.0-bnxt-218.0-1-4564106-offline_bundle-17360326.zip/metadata.zip/vibs/bnxtnet--817500090.xml","/VMW-ESX-6.5.0-bnxt-218.0-1-4564106-offline_bundle-17360326.zip/metadata.zip/vibs/bnxtroce-2119692319.xml","/VMW-ESX-6.5.0-bnxt-218.0-1-4564106-offline_bundle-17360326.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-bnxtnet-218.0.38.0.xml","/VMW-ESX-6.5.0-bnxt-218.0-1-4564106-offline_bundle-17360326.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-bnxtroce-218.0.16.0.xml"],"md5sum":"888b963a3d1cdf1138f8392f166850b9","name":"cp045073.zip","release":"2021-01-14T06:16:06","revision":"0","sha1sum":"263568c9eca3a586b59481fe3c8a5a0716ee119a","size":"333KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec158e843a","20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476"],"type_of_change":"0","version":"2021.04.05","vib_list":[{"name":"bnxtnet","version":"218.0.38.0-1OEM.650.0.0.4598673"},{"name":"bnxtroce","version":"218.0.16.0-1OEM.650.0.0.4598673"}]}],"id":{"product":"e382d013e99549e7a97161015561d31e","version":"6d7c2749736b46a2a8d83bec0de0b73d"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere 6.5"},{"lang":"ja","x_late":"HPE Broadcom NetXtreme-E ドライバー for VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue where RDMA Ethernet Controller error description on ESXi Host.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product corrects an issue which Purple Screen Of Death (PSOD) while running &nbsp;Virtual SAN (vSAN) over &nbsp;Remote Direct Memory Access (RDMA) traffic due to invalid Completion Queue Element (CQEs)</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"bnxtnet:218.0.38.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"},{"name":"bnxtroce:218.0.16.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains be2net drivers for the HPE Emulex 10/20GbE Server Adapters running under Red Hat Enterprise Linux 7 x86_64."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7 x86_64で動作するHPE Emulex 10/20GbE サーバーアダプター用のbe2netドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"100859","datemodified":"2021-01-14T07:19:25","file_list":["./etc/depmod.d/be2net.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/be2net","./lib/modules/3.10.0-1160.el7.x86_64/extra/be2net/be2net.ko","./usr/share/smartupdate/kmod-be2net/component.xml"],"md5sum":"2af0f156d813885ad60dd90dbf3c0913","name":"kmod-be2net-12.0.1342.0-1.rhel7u9.x86_64.rpm","release":"2021-01-14T07:13:05","revision":"0","sha1sum":"a66b7aaddc230597c9153aa9221b1e7d40eb1c2e","size":"98KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec6bd37e40"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"100863","datemodified":"2021-01-14T07:23:05","file_list":["./etc/depmod.d/be2net.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/be2net","./lib/modules/3.10.0-1127.el7.x86_64/extra/be2net/be2net.ko","./usr/share/smartupdate/kmod-be2net/component.xml"],"md5sum":"8d03323d34aff4826670cd28a059346e","name":"kmod-be2net-12.0.1342.0-1.rhel7u8.x86_64.rpm","release":"2021-01-14T07:13:05","revision":"0","sha1sum":"b9b8b6aeae0d006d85e816f05b9b69556bdbde31","size":"98KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec6bd37e40"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"47f79ff4032545a7bdbbbdab76c5b9b2","version":"d975e0a231f5496c80ea72988a8242ca"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Emulex 10/20GbE Drivers for Red Hat Enterprise Linux 7 x86_64"},{"lang":"ja","x_late":"HPE Emulex 10/20GbE ドライバー for Red Hat Enterprise Linux 7 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0728","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c220a","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c21d4","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072815908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 7 Update 8 and&nbsp;Red Hat Enterprise Linux 7 Update 9.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"kmod-be2net","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2net","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2net","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2net","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The Smart Storage Administrator CLI is a commandline-based disk configuration program for Smart Array Controllers and SmartRAID Controllers."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[],"id":{"product":"588f8b4e0f7d4e1194cebf99c3883026","version":"eb69f4ceeceb488bb05ff57f08b15e1b"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Installing VIBs on the ESXi 6.7 host from the ESXi shell:</strong></p>\n\n<ul>\n\t<li>Transfer the VIB(s) onto the ESXi host local path</li>\n\t<li>Run the following esxcli command on the ESXi shell to install the VIB(s):</li>\n</ul>\n\n<p><strong>~# esxcli software vib install -v &lt;path&gt;&lt;filename.vib&gt;</strong></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Smart Storage Administrator (SSA) CLI for VMware 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-09T05:34:04","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Adding support to the HPE SR Gen10 Plus Controllers.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U38","value":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"key":"U38","value":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"key":"","value":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U14","value":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U27","value":"HPE ProLiant XL2x260w Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"","value":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"","value":"HPE ProLiant ML150 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"","value":"HPE ProLiant XL770f Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000GWXKK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG08acHPG3.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304757584b4b","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB016000GWXKK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online HDD/SSD&nbsp;Flash Component for VMware ESXi - MB016000GWXKK&nbsp;Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"17574866","datemodified":"2021-08-27T18:37:33","file_list":["/CP049128_BUILD_1.data","/CP049128.vmexe","/CP049128.vmexe64","/CP049128.vmfile","/CP049128_VMw.zip","/CP049128.xml","/payload.json","/CP049128_VMw.zip/index.xml","/CP049128_VMw.zip/vendor-index.xml","/CP049128_VMw.zip/metadata.zip","/CP049128_VMw.zip/vib20/CP049128/HPE_bootbank_CP049128_HPG3.1-7.0.0.15843807.vib","/CP049128_VMw.zip/metadata.zip/vendor-index.xml","/CP049128_VMw.zip/metadata.zip/vmware.xml","/CP049128_VMw.zip/metadata.zip/vibs/CP049128-1230566697150109975.xml","/CP049128_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049128_HPG3.1-7.0.0.15843807.xml"],"md5sum":"9fa994f80ae0ffb0e59c5168f097b299","name":"CP049128.zip","release":"2021-08-27T18:32:14","revision":"0","sha1sum":"241b43d7b5a337e69d811e369fd45691e01594ec","size":"16MB","target_guids":["4d2340a5-3042-3631-3030-304757584b4b"],"type_of_change":"1","version":"HPG3","vib_list":[{"name":"CP049128","version":"HPG3.1-7.0.0.15843807"}]}],"id":{"product":"660aa31b4e5e4c7fa47517faf21f93a1","version":"7cdfdd389d2c483db246d2f48a569e1d"},"installation":{"command":"CP041025.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB016000GWXKK Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB016000GWXKK","target_guid":"4d2340a5-3042-3631-3030-304757584b4b","type":"sata"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T16:18:05","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This firmware&nbsp;revision corrects a rare situation where a Cryptographic Erase could result in random data instead of the expected deterministic zeros. This is judged as low severity because it does not compromise user data or security, but justifies the update to preclude potential security concerns. There are several items that reduce the probability of hangs and provide some minor performance improvements.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB016000GWXKK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The Smart Storage Administrator CLI is a commandline-based disk configuration program for Smart Array Controllers and SmartRAID Controllers."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[],"id":{"product":"acb3ec08a52044479314367689d164e9","version":"c9f99fa04d47406c945ecbbe98316fde"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Installing VIBs on the ESXi 6.5 host from the ESXi shell:</strong></p>\n\n<ul>\n\t<li>Transfer the VIB(s) onto the ESXi host local path</li>\n\t<li>Run the following esxcli command on the ESXi shell to install the VIB(s):</li>\n</ul>\n\n<p><strong>~# esxcli software vib install -v &lt;path&gt;&lt;filename.vib&gt;</strong></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Smart Storage Administrator (SSA) CLI for VMware 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-09T05:32:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Adding support&nbsp;to the HPE&nbsp;SR Gen10 Plus&nbsp;Controllers.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>.</p>\n\n<p>&nbsp;</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U38","value":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"key":"U38","value":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"key":"","value":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U14","value":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U27","value":"HPE ProLiant XL2x260w Gen9 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"","value":"HPE ProLiant ML150 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"","value":"HPE ProLiant XL770f Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000800KWWFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3830-304b57574645","Version":"HPK3"},{"DeviceName":"MK001600KWWFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3630-304b57574646","Version":"HPK3"},{"DeviceName":"MK003200KWWFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3230-304b57574648","Version":"HPK3"},{"DeviceName":"MK006400KWWFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3630-3430-304b5757464b","Version":"HPK3"},{"DeviceName":"VK000960KWWFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304b5757464c","Version":"HPK3"},{"DeviceName":"VK001920KWWFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304b5757464e","Version":"HPK3"},{"DeviceName":"VK003840KWWFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304b57574650","Version":"HPK3"},{"DeviceName":"VK007680KWWFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-304b57574651","Version":"HPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows (x64) - MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>This FW change resolves a MCTP VDM compliance issue seen by iLO version 2.30.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111061en_us</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5176056","datemodified":"2021-07-24T09:25:26","file_list":["cp048463.xml","cpqsetup.exe","KPE60X1GHPK3.rel","payload.json","setup.dll"],"md5sum":"468b96e10eca4f975a4056812099d939","name":"cp048463.exe","release":"2021-07-24T09:18:14","revision":"0","sha1sum":"68171b461bc620baf89171e93774365ee39ada86","size":"4MB","target_guids":["4d2340a5-304b-3030-3830-304b57574645","4d2340a5-304b-3130-3630-304b57574646","4d2340a5-304b-3330-3230-304b57574648","4d2340a5-304b-3630-3430-304b5757464b","562340a5-304b-3030-3936-304b5757464c","562340a5-304b-3130-3932-304b5757464e","562340a5-304b-3330-3834-304b57574650","562340a5-304b-3730-3638-304b57574651"],"type_of_change":"2","version":"HPK3"}],"id":{"product":"d026cab87ecf46f4a70676c4643d63f0","version":"373486e94cc940cda7f4fdcefb8fb608"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) - MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Windows（x64）- MK000800KWWFE、MK001600KWWFF、MK003200KWWFH、MK006400KWWFK、VK000960KWWFL、VK001920KWWFN、VK003840KWWFP、およびVK007680KWWFQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VK007680KWWFQ","target_guid":"562340a5-304b-3730-3638-304b57574651","type":"nvme"},{"id":"MK006400KWWFK","target_guid":"4d2340a5-304b-3630-3430-304b5757464b","type":"nvme"},{"id":"VK003840KWWFP","target_guid":"562340a5-304b-3330-3834-304b57574650","type":"nvme"},{"id":"MK003200KWWFH","target_guid":"4d2340a5-304b-3330-3230-304b57574648","type":"nvme"},{"id":"VK001920KWWFN","target_guid":"562340a5-304b-3130-3932-304b5757464e","type":"nvme"},{"id":"MK001600KWWFF","target_guid":"4d2340a5-304b-3130-3630-304b57574646","type":"nvme"},{"id":"VK000960KWWFL","target_guid":"562340a5-304b-3030-3936-304b5757464c","type":"nvme"},{"id":"MK00800KWWFE","target_guid":"002340a5-4b4d-3030-3830-304b57574645","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T12:11:38","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This FW change resolves a MCTP VDM compliance issue seen by iLO version 2.30.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111061en_us</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This FW change resolves a MCTP VDM compliance issue seen by iLO version 2.30.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111061en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK003840KWWFP","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK001600KWWFF","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK000800KWWFE","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK003200KWWFH","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK007680KWWFQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK001920KWWFN","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK000960KWWFL","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK006400KWWFK","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the vxn driver for HPE Intel ixn and ixt 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2016."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Microsoft Windows Server 2016で動作しているHPE Intel ixnおよびixt 10 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"961336","datemodified":"2021-02-01T06:42:48","file_list":["cp045153.xml","cpqsetup.exe","cp_data.xml","install.xml","NicCo5.dll","nicdrvr.dll","NicInVXN.dll","vxn65x64.cat","vxn65x64.din","vxn65x64.inf","vxn65x64.sys","vxnmsg.dll"],"md5sum":"a4433b94eae50802d431e6450eeed01b","name":"cp045153.exe","release":"2021-02-01T06:26:04","revision":"0","sha1sum":"951b7adc8ac79f75b7fb20e692ef4ee73324cc4e","size":"938KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec076f9a7c"],"type_of_change":"0","version":"2.1.192.0"}],"id":{"product":"8580226958cf4ea0a4c511ccdfa9e081","version":"2062eb0e8cbd4f7c9d5317075deb73d5"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel vxn Driver for Windows Server 2016"},{"lang":"ja","x_late":"HPE Intel vxnドライバー for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"152E","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d3","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"211B","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c211b","type":"pci","ven":"8086"},{"dev":"1530","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"1515","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c192d","type":"pci","ven":"8086"},{"dev":"1515","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c211a","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product contains Windows system update supported improvements.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">This product now&nbsp; supports the following the network adapters:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>HPE Ethernet 10Gb 2-port 561FLR-T Adapter</li>\n\t<li>HPE Ethernet 10Gb 2-port 561T Adapter</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"vxn65x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5906961","datemodified":"2021-05-18T16:06:47","file_list":["./usr/lib/i386-linux-gnu/firmware-system-u25-2.90_2021_04_29-1.1","./usr/lib/i386-linux-gnu/firmware-system-u25-2.90_2021_04_29-1.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-system-u25-2.90_2021_04_29-1.1/.setup","./usr/lib/i386-linux-gnu/firmware-system-u25-2.90_2021_04_29-1.1/CP047896.xml","./usr/lib/i386-linux-gnu/firmware-system-u25-2.90_2021_04_29-1.1/U25_2.90_04_29_2021.signed.flash","./usr/lib/i386-linux-gnu/firmware-system-u25-2.90_2021_04_29-1.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-system-u25-2.90_2021_04_29-1.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP047896.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP047896.scexe"],"md5sum":"63b8d18d43ef17238acf303a56b3f44e","name":"firmware-system-u25-2.90_2021_04_29-1.1.i386.rpm","release":"2021-05-18T15:58:07","revision":"0","sha1sum":"30067d5eb9d35879c48ce4eec9d7c172e36a68c4","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021"}],"id":{"product":"760219007fb741b7ab3268ea14a28fcd","version":"7f0c0a847ef14452ad31e41888c9a85d"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HPE ProLiant Agentless Management Service (<strong>AMS</strong>) and HPE SNMP Agents (<strong>SNMP Agents</strong>) are both running.&nbsp; HPE does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager 8.0.0 or later, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、iLOとの通信ができない場合に失敗します。  これは、HPE ProLiant Agentless Management Service (<strong>AMS</strong>)およびHPE SNMPエージェント(<strong>SNMP Agents</strong>)の両方が実行されているときに発生します。  HPEでは、AMSおよびSNMPエージェントを同時に実行させないことを推奨します。  「iLO device not found」エラーが発生した場合、AMSまたはSNMPエージェントを停止させて、再度フラッシュコンポーネントを実行します。<br />\n<br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上のSmart Update Manager 8.0.0以降を使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant XL270d (U25) Accelerator Tray"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Linux - HPE ProLiant XL270d (U25) アクセラレータトレイ"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-06T16:25:11","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","latest_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358.  These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390.  These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"}],"sw_keys":[{"name":"U25","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]},{"key":"7800374","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"en","x_late":"This package contains utilities and libraries to enable HPE Storage fibre channel array connectivity on Red Hat Enterprise Linux 7 Server for Emulex Host Bus Adapters and Mezzanine Host Bus Adapters"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1762383","datemodified":"2021-08-26T07:39:45","file_list":["./opt/emulex/rhel7/i386/lib/libdfc.so","./opt/emulex/rhel7/i386/lib/libdfc.so.12","./opt/emulex/rhel7/i386/lib/libdfc.so.12.8.526","./opt/emulex/rhel7/i386/lib/libemsdm.so","./opt/emulex/rhel7/i386/lib/libemulexhbaapi.so","./opt/emulex/rhel7/x86_64/lib64/libdfc.so","./opt/emulex/rhel7/x86_64/lib64/libdfc.so.12","./opt/emulex/rhel7/x86_64/lib64/libdfc.so.12.8.526","./opt/emulex/rhel7/x86_64/lib64/libemsdm.so","./opt/emulex/rhel7/x86_64/lib64/libemulexhbaapi.so","./usr/lib/libdfc.so","./usr/lib/libdfc.so.12","./usr/lib/libdfc.so.12.8.526","./usr/lib/libemsdm.so","./usr/lib/libemulexhbaapi.so","./usr/lib64/libdfc.so","./usr/lib64/libdfc.so.12","./usr/lib64/libdfc.so.12.8.526","./usr/lib64/libemsdm.so","./usr/lib64/libemulexhbaapi.so","./usr/share/smartupdate/HPE-CNA-FC-Emulex-Enablement-Kit/component.xml"],"md5sum":"a7427c8bee8493010d75ced13ff5a255","name":"HPE-CNA-FC-Emulex-Enablement-Kit-12.8.526.0-1.rhel7.x86_64.rpm","release":"2021-08-26T07:32:24","revision":"0","sha1sum":"1b6f362c3ae2d532ac75f0c072c296310bfe497e","size":"1MB","target_guids":[],"type_of_change":"1","version":"12.8.526.0"}],"id":{"product":"83782b2fc45743828072431284346eca","version":"656ac43a308948868521f3a52bd538a6"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The target environment must have the libHBAAPI Package installed prior to the installation of the enablement kit. (If not already present, the libHBAAPI Package can be obtained from the operating system installation media.)</p>\n\n<p>This version of the enablement kit does not provide the additional functionality of rebuilding the ram disk or setting driver parameters as the previous versions had done.&nbsp; Please refer to the &ldquo;Additional setup&rdquo; section of the Native Linux Device-Mapper Multipath for HPE StorageWorks Arrays reference guide for instructions on how to perform these functions.&nbsp; The reference guide is available at the following link:</p>\n\n<p><a href=\"http://www.hpe.com/storage/spock/\">http://www.hpe.com/storage/spock/</a></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex Fibre Channel Enablement Kit for Host Bus Adapters and Mezzanine Host Bus Adapters for Red Hat Enterprise Linux 7 Server"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"F100","subven":"10DF","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T10:35:54","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to version 12.8.526.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"HPE-CNA-FC-Emulex-Enablement-Kit","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWKGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAnAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a574b4755","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB004000JWKGU"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB004000JWKGU"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB004000JWKGU Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD1<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp; </strong>None</p>\n"}],"files":[{"bytes":"18758157","datemodified":"2021-08-30T20:02:06","file_list":["/CP048321_BUILD_2.data","/CP048321.vmexe","/CP048321.vmexe64","/CP048321.vmfile","/CP048321_VMw.zip","/CP048321.xml","/payload.json","/CP048321_VMw.zip/index.xml","/CP048321_VMw.zip/vendor-index.xml","/CP048321_VMw.zip/metadata.zip","/CP048321_VMw.zip/vib20/CP048321/HPE_bootbank_CP048321_HPD2.2-7.0.0.15843807.vib","/CP048321_VMw.zip/metadata.zip/vendor-index.xml","/CP048321_VMw.zip/metadata.zip/vmware.xml","/CP048321_VMw.zip/metadata.zip/vibs/CP048321-6459550740057422470.xml","/CP048321_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048321_HPD2.2-7.0.0.15843807.xml"],"md5sum":"81c70eaf9bb042feef42361a07b21509","name":"CP048321.zip","release":"2021-08-30T19:56:49","revision":"0","sha1sum":"3b6ed62200c73ee8f394632ff3c2e86f0d8a915d","size":"17MB","target_guids":["4d2340a5-3042-3430-3030-304a574b4755"],"type_of_change":"1","version":"HPD2","vib_list":[{"name":"CP048321","version":"HPD2.2-7.0.0.15843807"}]}],"id":{"product":"787f189347ac420fbe52f5e6292d569d","version":"1dd0b933ff2848d1862028b3dcc7dd99"},"installation":{"command":"CP041492.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB004000JWKGU Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB004000JWKGUドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB004000JWKGU","target_guid":"4d2340a5-3042-3430-3030-304a574b4755","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-04T12:36:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB004000JWKGU","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960RWUEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALSHPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554556","Version":"HPD6"},{"DeviceName":"VO001920RWUFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALSHPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554641","Version":"HPD6"},{"DeviceName":"VO003840RWUFB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALSHPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554642","Version":"HPD6"},{"DeviceName":"VO007680RWUFC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALSHPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-305257554643","Version":"HPD6"},{"DeviceName":"VO000960RWUFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALSHPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554644","Version":"HPD6"},{"DeviceName":"VO001920RWUFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALSHPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554645","Version":"HPD6"},{"DeviceName":"VO003840RWUFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALSHPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554646","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO000960RWUEV、VO001920RWUFA、VO003840RWUFB、VO007680RWUFC、VO000960RWUFD、VO001920RWUFE およびVO003840RWUFF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>TBD</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3489120","datemodified":"2021-08-26T07:11:43","file_list":["cp049365.xml","cpqsetup.exe","payload.json","setup.dll","TARM5ALSHPD6.rel"],"md5sum":"a4308be18e8c731bc579d271b7f5622b","name":"cp049365.exe","release":"2021-08-26T07:03:42","revision":"0","sha1sum":"6700526fc67150b5fe1e69fa5bb9635ba288d5f3","size":"3MB","target_guids":["562340a5-304f-3030-3936-305257554556","562340a5-304f-3130-3932-305257554641","562340a5-304f-3330-3834-305257554642","562340a5-304f-3730-3638-305257554643","562340a5-304f-3030-3936-305257554644","562340a5-304f-3130-3932-305257554645","562340a5-304f-3330-3834-305257554646"],"type_of_change":"1","version":"HPD6"}],"id":{"product":"dd83343964ed4806840a86595ee2254d","version":"b4bc8f4a1bcb4c46b831da890608c6d2"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  VO000960RWUEV、VO001920RWUFA、VO003840RWUFB、VO007680RWUFC、VO000960RWUFD、VO001920RWUFE およびVO003840RWUFFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VO007680RWUFC","target_guid":"562340a5-304f-3730-3638-305257554643","type":"sas"},{"id":"VO003840RWUFF","target_guid":"562340a5-304f-3330-3834-305257554646","type":"sas"},{"id":"VO003840RWUFB","target_guid":"562340a5-304f-3330-3834-305257554642","type":"sas"},{"id":"VO001920RWUFE","target_guid":"562340a5-304f-3130-3932-305257554645","type":"sas"},{"id":"VO001920RWUFA","target_guid":"562340a5-304f-3130-3932-305257554641","type":"sas"},{"id":"VO000960RWUFD","target_guid":"562340a5-304f-3030-3936-305257554644","type":"sas"},{"id":"VO000960RWUEV","target_guid":"562340a5-304f-3030-3936-305257554556","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-26T07:00:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Change Vendor Identification Field (VID data) from &quot;HP&quot; to &quot;HPE&quot;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>TBD</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO000960RWUFD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO007680RWUFC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000960RWUEV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003840RWUFB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003840RWUFF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920RWUFA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920RWUFE","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6372751","datemodified":"2021-05-17T21:14:47","file_list":["./usr/lib/i386-linux-gnu/firmware-system-i36-2.90_2021_04_29-1.1","./usr/lib/i386-linux-gnu/firmware-system-i36-2.90_2021_04_29-1.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-system-i36-2.90_2021_04_29-1.1/.setup","./usr/lib/i386-linux-gnu/firmware-system-i36-2.90_2021_04_29-1.1/CP047767.xml","./usr/lib/i386-linux-gnu/firmware-system-i36-2.90_2021_04_29-1.1/I36_2.90_04_29_2021.signed.flash","./usr/lib/i386-linux-gnu/firmware-system-i36-2.90_2021_04_29-1.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-system-i36-2.90_2021_04_29-1.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP047767.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP047767.scexe"],"md5sum":"d9a6c58fbfcc6ac9229d57f7627be1c8","name":"firmware-system-i36-2.90_2021_04_29-1.1.i386.rpm","release":"2021-05-17T21:04:06","revision":"0","sha1sum":"830ecfa6e1f209fc31f5ec9c63ad645bfe561e6f","size":"6MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021"}],"id":{"product":"65b84b051d254111871da2f18ceee59a","version":"dd8b617af7d64521b93b65bb95c6785e"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HPE ProLiant Agentless Management Service (<strong>AMS</strong>) and HPE SNMP Agents (<strong>SNMP Agents</strong>) are both running.&nbsp; HPE does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager&nbsp;8.0.0 or later, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>重要: このコンポーネントは、iLOとの通信ができない場合に失敗します。  これは、HPE ProLiant Agentless Management Service (<strong>AMS</strong>)およびHPE SNMPエージェント(<strong>SNMP Agents</strong>)の両方が実行されているときに発生します。  HPEでは、AMSおよびSNMPエージェントを同時に実行させないことを推奨します。  「iLO device not found」エラーが発生した場合、AMSまたはSNMPエージェントを停止させて、再度フラッシュコンポーネントを実行します。<br />\n<br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br/> <br/>\nRPMパッケージをインストールします<br/>> rpm -Uvh <filename>.rpm<br/> <br/>ファイルが置かれる場所を確認します<br/>> rpm -qlp <filename>.rpm<br/> <br/>前の手順で確認したディレクトリに移動し、コマンドプロンプトで‘./hpqsetup’と入力してhpqsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上のSmart Update Manager 8.0.0以降を使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant BL460c Gen9/WS460c Gen9 (I36) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant BL460c Gen9/WS460c Gen9（I36）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Oracle Linux 6 (AMD64/EMT64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Oracle Linux 7","platform":"Oracle Enterprise Linux","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Workstation (x86-64)","platform":"red_hat_enterprise_linux_client_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Workstation (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-29T15:59:43","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","latest_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358.  These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390.  These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"I36","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"nmlx4 is the low level driver implementation for the ConnectX®-3 and ConnectX®-3 Pro adapters for VMware ESXi 6.5 Mellanox Ethernet Adapters."},{"lang":"ja","x_late":"nmlx4は、VMware ESXi 6.5 Mellanoxイーサーネットアダプター用ConnectX®-3およびConnectX®-3 Proアダプターの低レベルドライバー実装です。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"2798457","datemodified":"2020-11-24T07:55:32","file_list":["/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip","/cp046261.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/doc/README.txt","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/doc/release_note_nmlx4-rdma_3.16.70.2-1OEM.650.0.0.4598673.pdf","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/doc/release_note_nmlx4-core_3.16.70.2-1OEM.650.0.0.4598673.pdf","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/doc/release_note_nmlx4-en_3.16.70.2-1OEM.650.0.0.4598673.pdf","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip/index.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip/vendor-index.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip/metadata.zip","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip/vib20/nmlx4-rdma/MEL_bootbank_nmlx4-rdma_3.16.70.2-1OEM.650.0.0.4598673.vib","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip/vib20/nmlx4-en/MEL_bootbank_nmlx4-en_3.16.70.2-1OEM.650.0.0.4598673.vib","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip/vib20/nmlx4-core/MEL_bootbank_nmlx4-core_3.16.70.2-1OEM.650.0.0.4598673.vib","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip/metadata.zip/vendor-index.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip/metadata.zip/vmware.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip/metadata.zip/vibs/nmlx4-rdma-1214697530.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip/metadata.zip/vibs/nmlx4-en-1132928091.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip/metadata.zip/vibs/nmlx4-core--114843923.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-nmlx4_core-3.16.70.2.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-nmlx4_en-3.16.70.2.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-nmlx4_rdma-3.16.70.2.xml"],"md5sum":"8e137dace023b758639d11e15d219cdc","name":"cp046261.zip","release":"2020-11-24T07:53:10","revision":"0","sha1sum":"fcbe6c42a7eeafff1b7d123fe1e5504d5453e6d9","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec0427da2e","20a6e8e4-bf33-4c71-a6bf-d9ec50f64a40","20a6e8e4-bf33-4c71-a6bf-d9ec34a24f7b"],"type_of_change":"1","version":"2020.11.11","vib_list":[{"name":"nmlx4-core","version":"3.16.70.2-1OEM.650.0.0.4598673"},{"name":"nmlx4-en","version":"3.16.70.2-1OEM.650.0.0.4598673"},{"name":"nmlx4-rdma","version":"3.16.70.2-1OEM.650.0.0.4598673"}]}],"id":{"product":"4fdb2c37f619467eb44cb380a68bf092","version":"26a0e9fca5e04cc2bbfae7a4598f52e4"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Remote Online:&nbsp;</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the HPE USB Key Creator Utility.&nbsp;</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux .</li>\n\t<li>cd /SPP20xxxxx/ and launch SUM&nbsp;(launch_sum.bat for Windows and ./launch_sum.sh for Linux).</li>\n\t<li>Select &quot;Baseline Library&quot; and wait for the Baseline inventory to complete.</li>\n\t<li>Select &quot;Nodes&quot; from the &quot;Smart Update Manager x.x.x&quot; drop down.</li>\n\t<li>Click, &quot;Add Node&quot;.\n\t<ul>\n\t\t<li>If adding a Gen9 server,\n\t\t<ul>\n\t\t\t<li>Provide IP address of the ESXi host.</li>\n\t\t\t<li>Enter&nbsp;the ESXi host credentials (root or administrator username and password)&nbsp;</li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>If adding a Gen10 and above server,\n\t\t<ul>\n\t\t\t<li>Provide iLO IP address of the ESXi host server.</li>\n\t\t\t<li>Enter the iLO credentials of the ESXi host server.</li>\n\t\t</ul>\n\t\t</li>\n\t</ul>\n\t</li>\n\t<li>Follow&nbsp;Smart Update Manager Steps and complete the driver update.&nbsp;</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware VUM or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands.</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"nmlx4_en Driver Component for VMware 6.5"},{"lang":"ja","x_late":"nmlx4_enドライバーコンポーネント for VMware 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"1003","subdev":"1777","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1003103c1777","type":"pci","ven":"15B3"},{"dev":"1003","subdev":"18CF","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1003103c18cf","type":"pci","ven":"15B3"},{"dev":"1003","subdev":"18D6","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1003103c18d6","type":"pci","ven":"15B3"},{"dev":"1003","subdev":"18CD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1003103c18cd","type":"pci","ven":"15B3"},{"dev":"1003","subdev":"18CE","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1003103c18ce","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-11T12:10:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Changes and New Features in version 3.16.11.10:</strong></p>\n\n<ul>\n\t<li>Resolved an issue that caused the network adapter traffic to stop.</li>\n\t<li>Fixed an internal multicast loopback issue that broke LACP(Link Aggregation Control Protocol) bonding protocol.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>Changes and New Features in version 3.16.11.10:</strong></p>\n\n<ul>\n\t<li>Resolved an issue that caused the network adapter traffic to stop.</li>\n\t<li>Fixed an internal multicast loopback issue that broke LACP(Link Aggregation Control Protocol) bonding protocol.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"nmlx4-core:3.16.70.2-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"},{"name":"nmlx4-rdma:3.16.70.2-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"},{"name":"nmlx4-en:3.16.70.2-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GEXXV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRETG2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745585856","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB6000GEXXV Drives "},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： MB6000GEXXVドライブ "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB6000GEXXV Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"5246557","datemodified":"2021-07-23T07:32:28","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a629fcea59-HPG2-10.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-a629fcea59-HPG2-10.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a629fcea59-HPG2-10.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a629fcea59-HPG2-10.1/CP048168.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a629fcea59-HPG2-10.1/TTMRETG2.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-a629fcea59-HPG2-10.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a629fcea59-HPG2-10.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a629fcea59-HPG2-10.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a629fcea59-HPG2-10.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048168.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048168.scexe"],"md5sum":"1495a8539dbdf9be0de67ec004e6a091","name":"firmware-hdd-a629fcea59-HPG2-10.1.x86_64.rpm","release":"2021-07-23T07:20:16","revision":"0","sha1sum":"8e3ccfa9468bc3cb3d607150c702742c5c264987","size":"5MB","target_guids":["002340a5-4d00-3642-3030-304745585856"],"type_of_change":"1","version":"HPG2"}],"id":{"product":"0514481c6d244017bb9549a474c6c48c","version":"ad613143fd14434fbb4f1d2ded920131"},"installation":{"command":"CP040292.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB6000GEXXV Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB6000GEXXVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB6000GEXXV","target_guid":"002340a5-4d00-3642-3030-304745585856","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T19:41:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000GEXXV","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5977256","datemodified":"2021-05-18T03:41:46","file_list":["P89_2.90_04_29_2021.signed.flash","SignedImageInstaller64.dll","cp047833.xml","cpqsetup.exe","cpqsysio64.sys"],"md5sum":"c8e4f6d16e6281335cd138eb3e23bc66","name":"cp047833.exe","release":"2021-05-18T03:24:20","revision":"0","sha1sum":"e82f6dd9cc032a454672c173c4f7ed91fa187342","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021"}],"id":{"product":"d9e09b131d654a8aa7aba135504d8639","version":"5789d0706aa04ba6a6aecca7c524d26f"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.<br />\n&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br />\n </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":" Online ROM Flash Component for Windows x64 - HPE ProLiant DL380 Gen9/DL360 Gen9 (P89) Servers"},{"lang":"ja","x_late":" オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant DL380 Gen9/DL360 Gen9（P89）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-05T02:55:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"}],"sw_keys":[{"name":"P89","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This driver, LSI_SAS2, provides Windows Server 2012 R2 support for HPE H2xx SAS/SATA Host Bus Adapter."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"1101576","datemodified":"2017-05-24T05:21:28","file_list":["cp032453.xml","cpqsetup.exe","driverconfigparam.def","generic.dll","install.xml","lsinodrv.inf","lsi_sas2.cat","lsi_sas2.inf","lsi_sas2.pdb","lsi_sas2.sys","lsi_sas2_win8.1_2012R2.txt","wdcfg.exe"],"md5sum":"c15d5383a67e23993ac74c9970188045","name":"cp032453.exe","release":"2017-05-24T05:20:05","revision":"0","sha1sum":"a7af52dfbe25436925f11b7be166a5c5f155ca50","size":"1MB","target_guids":[],"type_of_change":"0","version":"2.68.64.1"}],"id":{"product":"4ac92b6d48fb46ccad998db868b37deb","version":"bc7c672fa5b049139b43eed635d3c80d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number."},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。 ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。"}],"manufacturer_name":[{"lang":"en","x_late":"LSI Logic Corporation"}],"name":[{"lang":"en","x_late":"HPE H2xx SAS/SATA Host Bus Adapter Driver for Microsoft Windows Server 2012 R2 64-bit Editions"}],"prerequisites":{"required_diskspace":{"size_kb":"1440"},"supported_devices":[{"dev":"0087","subdev":"0042","subven":"1590","target_guid":"","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2017-06-12T00:35:07","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support for:</p>\n\n<ul>\n\t<li>Microsoft Windows Server 2016 - Server Core and Server with a Desktop.</li>\n</ul>\n\n<p><strong>Note:</strong> Revised component package. No change to driver functionality resulting from the change. If system has previously updated to driver version 2.68.64.2, then it is not necessary to update to 2.68.64.2(A).</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p style=\"margin-left:.1in\"><strong>Change implemented in version 2.68.64.1(B)</strong>:</p>\n\n<ul>\n\t<li>Updated to support Service Pack for ProLiant version 2017.07.0.<br />\n\t<strong>Note:</strong> If driver version 2.68.64.1 was previously installed, then it is not necessary to upgrade to version 2.68.64.1(B).</li>\n</ul>\n\n<p style=\"margin-left:.1in\"><strong>Enhancements/New Features implemented in version 2.68.64.1</strong>:</p>\n\n<ul>\n\t<li>Added support for Windows 8.1 and Windows Server 2012R2 to the build scripts.</li>\n\t<li>Add build support for new Windows Event Logging.</li>\n\t<li>Add support for automatic selection of the default driver build parameters file during the build</li>\n</ul>\n\n<p style=\"margin-left:1.0in\">&nbsp;</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"}],"sw_keys":[{"name":"lsi_sas2.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWBXQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAGLXYG8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304757425851","Version":"HPG8"},{"DeviceName":"MB008000GWBYL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAGLXYG8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-30475742594c","Version":"HPG8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB006000GWBXQ and MB008000GWBYL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB006000GWBXQ and MB008000GWBYL Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG6<br />\n<br />\n<strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"19053837","datemodified":"2021-08-30T20:06:08","file_list":["/CP048328_BUILD_2.data","/CP048328.vmexe","/CP048328.vmexe64","/CP048328.vmfile","/CP048328_VMw.zip","/CP048328.xml","/payload.json","/CP048328_VMw.zip/index.xml","/CP048328_VMw.zip/vendor-index.xml","/CP048328_VMw.zip/metadata.zip","/CP048328_VMw.zip/vib20/CP048328/HPE_bootbank_CP048328_HPG8.2-7.0.0.15843807.vib","/CP048328_VMw.zip/metadata.zip/vendor-index.xml","/CP048328_VMw.zip/metadata.zip/vmware.xml","/CP048328_VMw.zip/metadata.zip/vibs/CP048328-1596044245215242078.xml","/CP048328_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048328_HPG8.2-7.0.0.15843807.xml"],"md5sum":"a526d33745151de91334322009a5bd18","name":"CP048328.zip","release":"2021-08-30T20:00:55","revision":"0","sha1sum":"c4395bd8552f3f7e047053d76f76a997547704c3","size":"18MB","target_guids":["4d2340a5-3042-3630-3030-304757425851","4d2340a5-3042-3830-3030-30475742594c"],"type_of_change":"1","version":"HPG8","vib_list":[{"name":"CP048328","version":"HPG8.2-7.0.0.15843807"}]}],"id":{"product":"f2578af2166847fd869273fa7aa2c430","version":"9608bb4ef682476bb212701d6aa2fde3"},"installation":{"command":"CP040789.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB006000GWBXQ and MB008000GWBYL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB006000GWBXQおよびMB008000GWBYLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB006000GWBXQ","target_guid":"4d2340a5-3042-3630-3030-304757425851","type":"sata"},{"id":"MB008000GWBYL","target_guid":"4d2340a5-3042-3830-3030-30475742594c","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-05T17:57:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000GWBXQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB008000GWBYL","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under SUSE Linux Enterprise Server 12 SP5 x86_64."},{"lang":"ja","x_late":"この製品は、SUSE Linux Enterprise Server 12 SP5 x86_64下で実行されるサポートされたHPE Broadcom NetXtreme-Eアダプターカードに関するRoCE（RDMA over Converged Ethernet）ライブラリを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"23059","datemodified":"2021-02-11T00:40:04","file_list":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib64/libbnxt_re-218.0.7.0.so","./usr/lib64/libbnxt_re-rdmav22.so","./usr/lib64/libbnxt_re.so","./usr/share/smartupdate/libbnxt_re/component.xml"],"md5sum":"0e915653a80d4ceda0f5ff877e461ef5","name":"libbnxt_re-218.0.7.0-sles12sp5.x86_64.rpm","release":"2021-02-11T00:32:08","revision":"0","sha1sum":"d80ceba1a8b3e22bee061069bfe134b61ebbc94a","size":"22KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"type_of_change":"0","version":"218.0.7.0"}],"id":{"product":"a9179e239bb643d4b08c6272f4499a35","version":"d575131e632a4d9c8ae1bc9646cebfbe"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"text-align:left\">rpm -ivh &lt;bnxt_rooce &gt;.rpm --force [--replacefiles]</p>\n\n<p style=\"text-align:left\">Use --force or --replacefiles options while installing or updating the HPE Broadcom RoCE library which may conflict with inbox library</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E RoCE Library for SUSE Linux Enterprise Server 12 SP5"},{"lang":"ja","x_late":"SUSE Linux Enterprise Server 12 SP5用HPE Broadcom NetXtreme-E RoCEライブラリ"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>This product corrects an issue which RoCE bond is not getting created automatically after system reboot</li>\n\t<li>This product corrects an issue which errors/performance may degrades after hot plug operation is performed</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product now supports rdma-core v29(rdma user space application)</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"libbnxt_re","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960KXAVL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304b5841564c","Version":"HPK3"},{"DeviceName":"VO001920KXAVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304b58415650","Version":"HPK3"},{"DeviceName":"VO003840KXAVQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304b58415651","Version":"HPK3"},{"DeviceName":"VO007680KXAVR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304b58415652","Version":"HPK3"},{"DeviceName":"MO000800KXAVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304b5841564e","Version":"HPK3"},{"DeviceName":"MO001600KXAVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b58415654","Version":"HPK3"},{"DeviceName":"MO003200KXAVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b58415655","Version":"HPK3"},{"DeviceName":"MO006400KXAVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b58415656","Version":"HPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for&nbsp;VMware ESXi - VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp; HPK3</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPK2</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:<br />\n&nbsp; &nbsp; &nbsp; </strong>HPK2</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong>.</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>This Firmware release contains various drive interoperability enhancements and code fixes accumulated since the last firmware release, as well as a change to disable MCTP over PCIe VDM function per requested of HPE, and a PHY setting change for improved compatibility with Intel Ice Lake based Gen10+ DL360 platform.&nbsp;</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00115201en_us</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"22027739","datemodified":"2021-08-30T07:34:30","file_list":["/CP049302_BUILD_1.data","/CP049302.vmexe","/CP049302.vmexe64","/CP049302.vmfile","/CP049302_VMw.zip","/CP049302.xml","/payload.json","/CP049302_VMw.zip/index.xml","/CP049302_VMw.zip/vendor-index.xml","/CP049302_VMw.zip/metadata.zip","/CP049302_VMw.zip/vib20/CP049302/HPE_bootbank_CP049302_HPK3.1-7.0.0.15843807.vib","/CP049302_VMw.zip/metadata.zip/vendor-index.xml","/CP049302_VMw.zip/metadata.zip/vmware.xml","/CP049302_VMw.zip/metadata.zip/vibs/CP049302--4795136500392460299.xml","/CP049302_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049302_HPK3.1-7.0.0.15843807.xml"],"md5sum":"b7c36ddfb119ddcd9fb9ba27ed7aa324","name":"CP049302.zip","release":"2021-08-30T07:29:27","revision":"0","sha1sum":"215d47497599ad8b59924da45ddf4ce2923e9fba","size":"21MB","target_guids":["562340a5-304f-3030-3936-304b5841564c","562340a5-304f-3130-3932-304b58415650","562340a5-304f-3330-3834-304b58415651","562340a5-304f-3730-3638-304b58415652","4d2340a5-304f-3030-3830-304b5841564e","4d2340a5-304f-3130-3630-304b58415654","4d2340a5-304f-3330-3230-304b58415655","4d2340a5-304f-3630-3430-304b58415656"],"type_of_change":"2","version":"HPK3","vib_list":[{"name":"CP049302","version":"HPK3.1-7.0.0.15843807"}]}],"id":{"product":"eacabd6c758c41759c1c132130d3f614","version":"240cec76249d46c081bea5cd76ab50c8"},"installation":{"command":"CP042960.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>HP Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi - VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - VO000960KXAVL、VO001920KXAVP、VO003840KXAVQ、VO007680KXAVR、MO000800KXAVN、MO001600KXAVT、MO003200KXAVU、MO006400KXAVVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VO000960KXAVL","target_guid":"562340a5-304f-3030-3936-304b5841564c","type":"nvme"},{"id":"MO000800KXAVN","target_guid":"4d2340a5-304f-3030-3830-304b5841564e","type":"nvme"},{"id":"MO001600KXAVT","target_guid":"4d2340a5-304f-3130-3630-304b58415654","type":"nvme"},{"id":"MO003200KXAVU","target_guid":"4d2340a5-304f-3330-3230-304b58415655","type":"nvme"},{"id":"MO006400KXAVV","target_guid":"4d2340a5-304f-3630-3430-304b58415656","type":"nvme"},{"id":"VO003840KXAVQ","target_guid":"562340a5-304f-3330-3834-304b58415651","type":"nvme"},{"id":"VO007680KXAVR","target_guid":"562340a5-304f-3730-3638-304b58415652","type":"nvme"},{"id":"VO001920KXAVP","target_guid":"562340a5-304f-3130-3932-304b58415650","type":"nvme"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-17T12:28:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This Firmware release contains various drive interoperability enhancements and code fixes accumulated since the last firmware release, as well as a change to disable MCTP over PCIe VDM function per requested of HPE, and a PHY setting change for improved compatibility with Intel Ice Lake based Gen10+ DL360 platform.&nbsp;</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00115201en_us</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This Firmware release contains various drive interoperability enhancements and code fixes accumulated since the last firmware release, as well as a change to disable MCTP over PCIe VDM function per requested of HPE, and a PHY setting change for improved compatibility with Intel Ice Lake based Gen10+ DL360 platform.&nbsp;</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00115201en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO007680KXAVR","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO006400KXAVV","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO001600KXAVT","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO001920KXAVP","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO000960KXAVL","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO003840KXAVQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO003200KXAVU","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO000800KXAVN","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000JEQNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPSCDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a45514e4c","Version":"HPDB"},{"DeviceName":"MB6000JEQNN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPSCDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a45514e4e","Version":"HPDB"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB4000JEQNL and MB6000JEQNN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB4000JEQNL and MB6000JEQNN Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPDB<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"17527652","datemodified":"2021-08-26T20:03:54","file_list":["/CP048368_BUILD_2.data","/CP048368.vmexe","/CP048368.vmexe64","/CP048368.vmfile","/CP048368_VMw.zip","/CP048368.xml","/payload.json","/CP048368_VMw.zip/index.xml","/CP048368_VMw.zip/vendor-index.xml","/CP048368_VMw.zip/metadata.zip","/CP048368_VMw.zip/vib20/CP048368/HPE_bootbank_CP048368_HPDB.2-7.0.0.15843807.vib","/CP048368_VMw.zip/metadata.zip/vendor-index.xml","/CP048368_VMw.zip/metadata.zip/vmware.xml","/CP048368_VMw.zip/metadata.zip/vibs/CP048368--6638341273484569961.xml","/CP048368_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048368_HPDB.2-7.0.0.15843807.xml"],"md5sum":"c92f082d83d5a1ead06de5759bd88f06","name":"CP048368.zip","release":"2021-08-26T19:58:30","revision":"0","sha1sum":"2a7b7c4e28e2c0742e128c28c76b49774fbae6a6","size":"16MB","target_guids":["002340a5-4d00-3442-3030-304a45514e4c","002340a5-4d00-3642-3030-304a45514e4e"],"type_of_change":"1","version":"HPDB","vib_list":[{"name":"CP048368","version":"HPDB.2-7.0.0.15843807"}]}],"id":{"product":"dffb1787348c4681b9170fbc360355c9","version":"2410a722f1864073918a1550e3137a10"},"installation":{"command":"CP039424.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - MB4000JEQNL and MB6000JEQNN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - MB4000JEQNLおよびMB6000JEQNNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB4000JEQNL","target_guid":"002340a5-4d00-3442-3030-304a45514e4c","type":"sas"},{"id":"MB6000JEQNN","target_guid":"002340a5-4d00-3642-3030-304a45514e4e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-07T19:43:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JEQNL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB6000JEQNN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWJRR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06ACHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574a5252","Version":"HPG4"},{"DeviceName":"MB008000GWJRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06ACHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-3047574a5254","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB006000GWJRR and MB008000GWJRT Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB006000GWJRRおよびMB008000GWJRTドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB006000GWJRR and MB008000GWJRT&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"4863329","datemodified":"2021-07-23T09:42:19","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG4-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG4-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG4-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG4-4.1/CP048210.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG4-4.1/TAMG06ACHPG4.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG4-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG4-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG4-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG4-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048210.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048210.scexe"],"md5sum":"dd2942389e506e08e89ffa006669842f","name":"firmware-hdd-c993b31232-HPG4-4.1.x86_64.rpm","release":"2021-07-23T09:30:09","revision":"0","sha1sum":"33a87d34044c0d8dae5e904f0a7ff899c6add0ae","size":"4MB","target_guids":["4d2340a5-3042-3630-3030-3047574a5252","4d2340a5-3042-3830-3030-3047574a5254"],"type_of_change":"1","version":"HPG4"}],"id":{"product":"87b9a1c22150406cbf61d6b300753282","version":"6c38566fd3b242d996050ef74e0f389c"},"installation":{"command":"CP041676.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB006000GWJRR and MB008000GWJRT Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB006000GWJRRおよびMB008000GWJRTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB008000GWJRT","target_guid":"4d2340a5-3042-3830-3030-3047574a5254","type":"sata"},{"id":"MB006000GWJRR","target_guid":"4d2340a5-3042-3630-3030-3047574a5252","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T11:53:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000GWJRR","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB008000GWJRT","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"ET000750KWJTF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICSHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3054-3030-3735-304b574a5446","Version":"4ICSHPK4"},{"DeviceName":"EO000375KWJUC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICSHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3337-354b574a5543","Version":"4ICSHPK4"},{"DeviceName":"EO000750KWTXC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICSHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3735-304b57545843","Version":"4ICSHPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: ET000750KWJTF, EO000750KWTXC and EO000375KWJUC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for Linux (x64) - &nbsp;ET000750KWJTF, EO000750KWTXC and EO000375KWJUC Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp;&nbsp; 4ICSHPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; 4ICSHPK2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; 4ICSHPK2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p>\n\n<p style=\"text-align:left\">&nbsp; &nbsp; &nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"4663851","datemodified":"2021-07-23T08:44:43","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-c4355d15c4-4ICSHPK4-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-c4355d15c4-4ICSHPK4-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-c4355d15c4-4ICSHPK4-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c4355d15c4-4ICSHPK4-3.1/4ICSHPK4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-c4355d15c4-4ICSHPK4-3.1/CP048514.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-c4355d15c4-4ICSHPK4-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c4355d15c4-4ICSHPK4-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-c4355d15c4-4ICSHPK4-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-c4355d15c4-4ICSHPK4-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048514.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048514.scexe"],"md5sum":"f331e4bfd4384612550ce74b4c857e4e","name":"firmware-hdd-c4355d15c4-4ICSHPK4-3.1.x86_64.rpm","release":"2021-07-23T08:31:07","revision":"0","sha1sum":"6c3e141257d71f6baa9e70ab3fcf7bdd50cd00da","size":"4MB","target_guids":["452340a5-3054-3030-3735-304b574a5446","452340a5-304f-3030-3337-354b574a5543","452340a5-304f-3030-3735-304b57545843"],"type_of_change":"1","version":"4ICSHPK4"}],"id":{"product":"21d70f91419f44f0a429331de70ce506","version":"055d8cbe2bec45c980972fa75d8151a5"},"installation":{"command":"CP043037.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p><strong>Additional Information:</strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p><strong>追加情報:</strong></p>\n\n<p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/jp/servers/spp_dl\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - ET000750KWJTF, EO000750KWTXC and EO000375KWJUC Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - ET000750KWJTF、EO000750KWTXC、およびEO000375KWJUCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"ET000750KWJTF","target_guid":"452340a5-3054-3030-3735-304b574a5446","type":"nvme"},{"id":"EO000375KWJUC","target_guid":"452340a5-304f-3030-3337-354b574a5543","type":"nvme"},{"id":"EO000750KWTXC","target_guid":"452340a5-304f-3030-3735-304b57545843","type":"nvme"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T09:38:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMD enabled Intel VROC platform.</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>\n\t<p>Fixed HPK3 drive reports incorrect Device ID issue.</p>\n\t</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EO000375KWJUC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"EO000750KWTXC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"ET000750KWJTF","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001920KWZQR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173300HPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304b575a5152","Version":"HPK5"},{"DeviceName":"VO003840KWZQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173300HPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304b575a5154","Version":"HPK5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VO001920KWZQR and VO003840KWZQT"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO001920KWZQRおよびVO003840KWZQT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online NVMe SSD Flash Component for VMware ESXi -&nbsp;VO001920KWZQR and VO003840KWZQT Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPK5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPK3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPK3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"25282360","datemodified":"2021-08-27T04:27:36","file_list":["/CP048473_BUILD_3.data","/CP048473.vmexe","/CP048473.vmexe64","/CP048473.vmfile","/CP048473_VMw.zip","/CP048473.xml","/payload.json","/CP048473_VMw.zip/index.xml","/CP048473_VMw.zip/vendor-index.xml","/CP048473_VMw.zip/metadata.zip","/CP048473_VMw.zip/vib20/CP048473/HPE_bootbank_CP048473_HPK5.3-7.0.0.15843807.vib","/CP048473_VMw.zip/metadata.zip/vendor-index.xml","/CP048473_VMw.zip/metadata.zip/vmware.xml","/CP048473_VMw.zip/metadata.zip/vibs/CP048473-4202404720181768433.xml","/CP048473_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048473_HPK5.3-7.0.0.15843807.xml"],"md5sum":"340b1a86707d24cfefe1f8ec78ca4367","name":"CP048473.zip","release":"2021-08-27T04:22:26","revision":"0","sha1sum":"a752c8dbfc3ab0730832b31036adb76c1c93cc05","size":"24MB","target_guids":["562340a5-304f-3130-3932-304b575a5152","562340a5-304f-3330-3834-304b575a5154"],"type_of_change":"2","version":"HPK5","vib_list":[{"name":"CP048473","version":"HPK5.3-7.0.0.15843807"}]}],"id":{"product":"939eb4c97d9745fe9b103a023bb5c6ab","version":"dd2eec3d0b3e4eb88055f676c750f2ae"},"installation":{"command":"CP040631.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします。</li>\n\t<li>CPXXXXXX.vmexe(ESXi 6.7 &以前のバージョン)およびCPXXXXXX.vmexe64(ESXi 7.0)は、次のコマンドを使用して実行可能です:</li>\n</ul>\n\n<p>             chmod x CPXXXXXX.vmexe    または    chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPXXXXXX.vmexe(または)./CPXXXXXX.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi  - VO001920KWZQR and VO003840KWZQT Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi  - VO001920KWZQRおよびVO003840KWZQTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VO003840KWZQT","target_guid":"562340a5-304f-3330-3834-304b575a5154","type":"nvme"},{"id":"VO001920KWZQR","target_guid":"562340a5-304f-3130-3932-304b575a5152","type":"nvme"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T17:13:30","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO003840KWZQT","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO001920KWZQR","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWCPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTED9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57435048","Version":"HPD9"},{"DeviceName":"EH000600JWCPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTED9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57435046","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EH000600JWCPF and EH000900JWCPH"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：EH000600JWCPFおよびEH000900JWCPH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - &nbsp;EH000600JWCPF and EH000900JWCPH Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5739732","datemodified":"2021-07-23T08:19:18","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPD9-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPD9-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPD9-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPD9-2.1/CP048084.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPD9-2.1/SKESTED9.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPD9-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPD9-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPD9-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPD9-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048084.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048084.scexe"],"md5sum":"0f29aa37e355c102a36623e4282ccce2","name":"firmware-hdd-a05f29cef3-HPD9-2.1.x86_64.rpm","release":"2021-07-23T08:06:08","revision":"0","sha1sum":"fcf855b7439af09e2327a3246a6ae12f29d8ed04","size":"5MB","target_guids":["452340a5-3048-3030-3930-304a57435048","452340a5-3048-3030-3630-304a57435046"],"type_of_change":"1","version":"HPD9"}],"id":{"product":"365d207e25654d61b3829f731965d204","version":"c87573404f8a4121be2922a308346ff8"},"installation":{"command":"CP040712.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EH000600JWCPF and EH000900JWCPH Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux(x64) - EH000600JWCPFおよびEH000900JWCPHドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EH000600JWCPF","target_guid":"452340a5-3048-3030-3630-304a57435046","type":"sas"},{"id":"EH000900JWCPH","target_guid":"452340a5-3048-3030-3930-304a57435048","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T11:15:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH000900JWCPH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000600JWCPF","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO0480JFDGT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304f-3438-304a46444754","Version":"HPD9"},{"DeviceName":"VO0960JFDGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304f-3936-304a46444755","Version":"HPD9"},{"DeviceName":"VO1920JFDGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314f-3932-304a46444756","Version":"HPD9"},{"DeviceName":"VO3840JFDHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-334f-3834-304a46444841","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO0480JFDGT, VO0960JFDGU, VO1920JFDGV and VO3840JFDHA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - VO0480JFDGT, VO0960JFDGU, VO1920JFDGV and VO3840JFDHA Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD9</p>\n\n<p><strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD8</p>\n\n<p><strong>Previous Version of Firmware:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; HPD8</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Enhancements/New Features:&nbsp;</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p>\n"}],"files":[{"bytes":"3214024","datemodified":"2021-07-25T21:25:55","file_list":["cp048660.xml","cpqsetup.exe","GP1633D9.rel","payload.json","setup.dll"],"md5sum":"f76e8bb47952e995e5a5567f8f576a80","name":"cp048660.exe","release":"2021-07-25T21:18:14","revision":"0","sha1sum":"0e0923e2d12e6a927006b9473a817d093cebe37b","size":"3MB","target_guids":["002340a5-5600-304f-3438-304a46444754","002340a5-5600-304f-3936-304a46444755","002340a5-5600-314f-3932-304a46444756","002340a5-5600-334f-3834-304a46444841"],"type_of_change":"1","version":"HPD9"}],"id":{"product":"dc2f3874388f4d969828a39097a550e8","version":"66ea9ac1c02b4c39aa9c0eae29e6be28"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VO0480JFDGT, VO0960JFDGU, VO1920JFDGV and VO3840JFDHA Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - VO0480JFDGT、VO0960JFDGU、VO1920JFDGV、およびVO3840JFDHAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VO1920JFDGV","target_guid":"002340a5-5600-314f-3932-304a46444756","type":"sas"},{"id":"VO0480JFDGT","target_guid":"002340a5-5600-304f-3438-304a46444754","type":"sas"},{"id":"VO0960JFDGU","target_guid":"002340a5-5600-304f-3936-304a46444755","type":"sas"},{"id":"VO3840JFDHA","target_guid":"002340a5-5600-334f-3834-304a46444841","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-17T05:48:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO0960JFDGU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO0480JFDGT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO3840JFDHA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO1920JFDGV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000240GWKVK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3234-3047574b564b","Version":"HPG5"},{"DeviceName":"MK000480GWJPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-3047574a504e","Version":"HPG5"},{"DeviceName":"MK000960GWJPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-3047574a5050","Version":"HPG5"},{"DeviceName":"MK001920GWJPQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-3047574a5051","Version":"HPG5"},{"DeviceName":"VK000240GWJPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-3047574a5044","Version":"HPG5"},{"DeviceName":"VK000480GWJPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-3047574a5045","Version":"HPG5"},{"DeviceName":"VK000960GWJPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-3047574a5046","Version":"HPG5"},{"DeviceName":"VK001920GWJPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-3047574a5048","Version":"HPG5"},{"DeviceName":"VK003840GWJPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-3047574a504b","Version":"HPG5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Fixes a rare link loss issue and adds enhancements for drive reliability.</li>\n\t<li>After HPG5 firmware is downloaded to the drive, the new HPG5 firmware will be active on the drive.</li>\n\t<li>The new drive bootloader code will be activated after the next drive power cycle.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4918187","datemodified":"2021-07-26T05:47:00","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-6.1/4IYVHPG5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-6.1/CP048214.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048214.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048214.scexe"],"md5sum":"f9882f8eb60915807a51431798e07f11","name":"firmware-hdd-aef2a690c9-HPG5-6.1.x86_64.rpm","release":"2021-07-26T05:34:07","revision":"0","sha1sum":"8d4ac1db96724169f14f9b8c75d7bce5e9a15fad","size":"4MB","target_guids":["4d2340a5-304b-3030-3234-3047574b564b","4d2340a5-304b-3030-3438-3047574a504e","4d2340a5-304b-3030-3936-3047574a5050","4d2340a5-304b-3130-3932-3047574a5051","562340a5-304b-3030-3234-3047574a5044","562340a5-304b-3030-3438-3047574a5045","562340a5-304b-3030-3936-3047574a5046","562340a5-304b-3130-3932-3047574a5048","562340a5-304b-3330-3834-3047574a504b"],"type_of_change":"2","version":"HPG5"}],"id":{"product":"29456540dcc74eaf9f223e63cf50eff7","version":"886ac51dd32b4b329b0872d2280b5b3a"},"installation":{"command":"CP040776.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) -  VK000240GWJPD、VK000480GWJPE、VK000960GWJPF、VK001920GWJPH、VK003840GWJPK、MK000240GWKVK、MK000480GWJPN、MK000960GWJPP、およびMK001920GWJPQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MK001920GWJPQ","target_guid":"4d2340a5-304b-3130-3932-3047574a5051","type":"sata"},{"id":"VK001920GWJPH","target_guid":"562340a5-304b-3130-3932-3047574a5048","type":"sata"},{"id":"MK000240GWKVK","target_guid":"4d2340a5-304b-3030-3234-3047574b564b","type":"sata"},{"id":"VK000240GWJPD","target_guid":"562340a5-304b-3030-3234-3047574a5044","type":"sata"},{"id":"VK003840GWJPK","target_guid":"562340a5-304b-3330-3834-3047574a504b","type":"sata"},{"id":"MK000480GWJPN","target_guid":"4d2340a5-304b-3030-3438-3047574a504e","type":"sata"},{"id":"VK000480GWJPE","target_guid":"562340a5-304b-3030-3438-3047574a5045","type":"sata"},{"id":"MK000960GWJPP","target_guid":"4d2340a5-304b-3030-3936-3047574a5050","type":"sata"},{"id":"VK000960GWJPF","target_guid":"562340a5-304b-3030-3936-3047574a5046","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T12:23:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Fixes a rare link loss issue and adds enhancements for drive reliability.</li>\n\t<li>After HPG5 firmware is downloaded to the drive, the new HPG5 firmware will be active on the drive.</li>\n\t<li>The new drive bootloader code will be activated after the next drive power cycle.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us</a></li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Fixes a rare link loss issue and adds enhancements for drive reliability.</li>\n\t<li>After HPG5 firmware is downloaded to the drive, the new HPG5 firmware will be active on the drive.</li>\n\t<li>The new drive bootloader code will be activated after the next drive power cycle.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK001920GWJPQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GWJPH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000240GWKVK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWJPN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWJPP","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWJPE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWJPD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWJPF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GWJPK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800026","languages":[{"lang":"tw","x_late":"軟體 - 管理"},{"lang":"en","x_late":"Software - Management"},{"lang":"ko","x_late":"소프트웨어 - 관리"},{"lang":"ja","x_late":"ソフトウェア - マネジメント"},{"lang":"cn","x_late":"软件 - 管理"}]}],"description":[{"lang":"en","x_late":"The HPE iLO Driver allows software to communicate with the iLO management controller. This driver is used by the Agentless Management Service, firmware flash components, and other utilities. "}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"22041","datemodified":"2021-04-12T20:22:09","file_list":["/cp047518.xml","/ilo-driver_700.10.7.5.2-1OEM.700.1.0.15843807_17856914.zip","/ilo-driver_700.10.7.5.2-1OEM.700.1.0.15843807_17856914.zip/index.xml","/ilo-driver_700.10.7.5.2-1OEM.700.1.0.15843807_17856914.zip/vendor-index.xml","/ilo-driver_700.10.7.5.2-1OEM.700.1.0.15843807_17856914.zip/metadata.zip","/ilo-driver_700.10.7.5.2-1OEM.700.1.0.15843807_17856914.zip/vib20/ilo/HPE_bootbank_ilo_700.10.7.5.2-1OEM.700.1.0.15843807.vib","/ilo-driver_700.10.7.5.2-1OEM.700.1.0.15843807_17856914.zip/metadata.zip/vendor-index.xml","/ilo-driver_700.10.7.5.2-1OEM.700.1.0.15843807_17856914.zip/metadata.zip/vmware.xml","/ilo-driver_700.10.7.5.2-1OEM.700.1.0.15843807_17856914.zip/metadata.zip/vibs/ilo--2313206460127334238.xml","/ilo-driver_700.10.7.5.2-1OEM.700.1.0.15843807_17856914.zip/metadata.zip/bulletins/ilo-driver_700.10.7.5.2-1OEM.700.1.0.15843807.xml"],"md5sum":"e44a35ab20dbcbe3b8990b2a05d46201","name":"cp047518.zip","release":"2021-04-12T20:20:07","revision":"0","sha1sum":"2fd6961479ff8532f29d2641e1685cc45b121b47","size":"21KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec948d20a3","20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc"],"type_of_change":"1","version":"2021.09.01","vib_list":[{"name":"ilo","version":"700.10.7.5.2-1OEM.700.1.0.15843807"}]}],"id":{"product":"6439c3485f63410da139047f5f5bc562","version":"9bf4101945d34091a6f025aa513e9bd4"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To&nbsp;remotely install&nbsp;this&nbsp;bundle&nbsp; online using the HP Smart Update Manager (HPSUM) from the HP Service Pack for ProLiant (SPP):</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\">HPE USB Key Utility</a>.</li>\n\t<li>Copy&nbsp;this driver component&nbsp;to the directory<em> /SPP20xxxxx/hp/swpackages</em> on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.</li>\n\t<li>Change directories to <em>/hp/swpackages</em> and execute&nbsp;./hpsum.</li>\n\t<li>Select the &quot;next&quot; button.</li>\n\t<li>Click &quot;Add Single Target.&quot;</li>\n\t<li>Enter&nbsp;the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow HP Smart Update Manager&nbsp;instructions&nbsp;to complete the driver update.</li>\n</ol>\n\n<p><br />\n<strong>To&nbsp;install this bundle using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the component zip file to extract the driver offline bundle.</li>\n\t<li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li>\n</ol>\n\n<p>Refer to VMware documentation for information on the esxcli commands</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE iLO Driver Bundle Smart Component for ESXi 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"16"},"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-05T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Supports ESXi 7.0 and ESXi 7.0 U1</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Fixed driver unload function to allow controller to function properly on reload and when Quickboot is enabled.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"ilo-driver:700.10.7.5.2-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver.component:vmware:zip"},{"name":"ilo:700.10.7.5.2-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6300092","datemodified":"2021-05-18T02:52:40","file_list":["./usr/lib/i386-linux-gnu/firmware-system-p92-2.90_2021_04_29-1.1","./usr/lib/i386-linux-gnu/firmware-system-p92-2.90_2021_04_29-1.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-system-p92-2.90_2021_04_29-1.1/.setup","./usr/lib/i386-linux-gnu/firmware-system-p92-2.90_2021_04_29-1.1/CP047844.xml","./usr/lib/i386-linux-gnu/firmware-system-p92-2.90_2021_04_29-1.1/P92_2.90_04_29_2021.signed.flash","./usr/lib/i386-linux-gnu/firmware-system-p92-2.90_2021_04_29-1.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-system-p92-2.90_2021_04_29-1.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP047844.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP047844.scexe"],"md5sum":"7fcf3ca04dfd7eb14bd8e74af83987ed","name":"firmware-system-p92-2.90_2021_04_29-1.1.i386.rpm","release":"2021-05-18T02:42:16","revision":"0","sha1sum":"8d27d93ae0f2875f99678d2e611f9cf973628a34","size":"6MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021"}],"id":{"product":"ce67f450aba744c2b5fc3e256cda38aa","version":"7f71e55b38d549b6a396f54d055e872c"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HPE ProLiant Agentless Management Service (<strong>AMS</strong>) and HPE SNMP Agents (<strong>SNMP Agents</strong>) are both running.&nbsp; HPE does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager 8.0.0 or later, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>重要: このコンポーネントは、iLOとの通信ができない場合に失敗します。  これは、HPE ProLiant Agentless Management Service (<strong>AMS</strong>)およびHPE SNMPエージェント(<strong>SNMP Agents</strong>)の両方が実行されているときに発生します。  HPEでは、AMSおよびSNMPエージェントを同時に実行させないことを推奨します。  「iLO device not found」エラーが発生した場合、AMSまたはSNMPエージェントを停止させて、再度フラッシュコンポーネントを実行します。<br />\n<br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上のSmart Update Manager 8.0.0以降を使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant ML350 Gen9 (P92) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant ML350 Gen9(P92)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Oracle Linux 6 (AMD64/EMT64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Oracle Linux 7","platform":"Oracle Enterprise Linux","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-05T03:38:29","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"}],"sw_keys":[{"name":"P92","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"The HPE Storage Fibre Channel (FC) adapter kit contains version 12.8.351.7 of the Emulex Storport driver for Extended Systems which provides Fibre Channel-Host Bus Adapter (HBA) driver support for HPE Storage RAID Arrays."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"2311056","datemodified":"2021-08-26T06:33:24","file_list":["cp048600.xml","cpqsetup.exe","elxdrvr-fc-12.8.351.7-13.exe","ElxStorInstaller.dll","install.xml","SysConfig.frm","SysConfig.frm.ja"],"md5sum":"a6dfd7fc10d0934f4d48d84b2cad2799","name":"cp048600.exe","release":"2021-08-26T06:31:05","revision":"0","sha1sum":"558323d325abfd89ff8260742455adbc8daf2903","size":"2MB","target_guids":[],"type_of_change":"1","version":"12.8.351.7"}],"id":{"product":"57f941a559f84f0dbc1912c8c10fae0c","version":"7c8a1413c9714898bcdcf5d63cacb212"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation.</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Fibre Channel Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"F100","subven":"10DF","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T10:35:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to driver version&nbsp;12.8.351.7</p>\n\n<p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p>\n\n<p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p>\n\n<p>The extracted files are located:</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p>\n\n<p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2019</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"elxfc.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001920KWVMT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1723b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304b57564d54","Version":"HPK3"},{"DeviceName":"VO003840KWVMU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1723b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304b57564d55","Version":"HPK3"},{"DeviceName":"VO007680KWVMV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1723b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304b57564d56","Version":"HPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO001920KWVMT, VO003840KWVMU, and VO007680KWVMV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;NVMe SSD&nbsp;Flash Component for&nbsp;Windows (x64) - VO001920KWVMT, VO003840KWVMU, and VO007680KWVMV Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p><strong>&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"5390704","datemodified":"2021-07-24T09:22:08","file_list":["cp048462.xml","cpqsetup.exe","GP1723b0HPK3.rel","payload.json","setup.dll"],"md5sum":"383311c4a4f74cac9ef766c5bef7ecb1","name":"cp048462.exe","release":"2021-07-24T09:13:07","revision":"0","sha1sum":"ea55ae2340cfc42157ce5b248460d4375950b09f","size":"5MB","target_guids":["562340a5-304f-3130-3932-304b57564d54","562340a5-304f-3330-3834-304b57564d55","562340a5-304f-3730-3638-304b57564d56"],"type_of_change":"1","version":"HPK3"}],"id":{"product":"8ffd589c0d3c4586b8af1c72d7c3699f","version":"0a613232b7434285907811ff06761a89"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) - VO001920KWVMT, VO003840KWVMU, and VO007680KWVMV Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - VO001920KWVMT、VO003840KWVMU、およびVO007680KWVMVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VO007680KWVMV","target_guid":"562340a5-304f-3730-3638-304b57564d56","type":"nvme"},{"id":"VO003840KWVMU","target_guid":"562340a5-304f-3330-3834-304b57564d55","type":"nvme"},{"id":"VO001920KWVMT","target_guid":"562340a5-304f-3130-3932-304b57564d54","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T11:54:09","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Fixed SSD weargauge report error issue.</li>\n\t<li>Fixed Assign FWState as TR_DONE_ERR at the correct location.</li>\n\t<li>Prepare proper response data for Get Message Type Supported MCTP Command.</li>\n\t<li>Added code to preserve current feature values cross live firmware update.</li>\n\t<li>Allocate 4 bytes instead of 2 bytes for parameter code.</li>\n\t<li>Changed the value for NLB equal to NSize -1.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO007680KWVMV","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO003840KWVMU","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO001920KWVMT","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWWQB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a57575142","Version":"HPD6"},{"DeviceName":"MB002000JWWQA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a57575141","Version":"HPD6"},{"DeviceName":"MB001000JWWPV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304a57575056","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB004000JWWQB, MB002000JWWQA and MB001000JWWPV Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB004000JWWQB、MB002000JWWQA、およびMB001000JWWPVドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB004000JWWQB, MB002000JWWQA and MB001000JWWPV Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD4</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5801358","datemodified":"2021-07-23T09:23:17","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD6-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD6-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD6-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD6-2.1/CP048204.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD6-2.1/SCIMARRNNSD6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD6-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD6-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD6-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD6-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048204.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048204.scexe"],"md5sum":"e86d008e94d239c05360f4fd45353701","name":"firmware-hdd-adb3ab8147-HPD6-2.1.x86_64.rpm","release":"2021-07-23T09:11:11","revision":"0","sha1sum":"c9d59a51d15910b09c4e661443803d99ed992fb0","size":"5MB","target_guids":["4d2340a5-3042-3430-3030-304a57575142","4d2340a5-3042-3230-3030-304a57575141","4d2340a5-3042-3130-3030-304a57575056"],"type_of_change":"1","version":"HPD6"}],"id":{"product":"6559625804344daab70667e2f1b0b044","version":"76dcd51cb75c421d9076c5eb660cb2e2"},"installation":{"command":"CP043262.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート:</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするには、以下のコマンドの<strong>1つ</strong>を実行します:\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>（.rpm拡張子の付いていないrpmファイル名）を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するには Service Pack for ProLiant から以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB004000JWWQB, MB002000JWWQA and MB001000JWWPV Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for Linux (x64) - MB004000JWWQB、MB002000JWWQA、およびMB001000JWWPVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB004000JWWQB","target_guid":"4d2340a5-3042-3430-3030-304a57575142","type":"sas"},{"id":"MB002000JWWQA","target_guid":"4d2340a5-3042-3230-3030-304a57575141","type":"sas"},{"id":"MB001000JWWPV","target_guid":"4d2340a5-3042-3130-3030-304a57575056","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T11:27:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB002000JWWQA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB001000JWWPV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB004000JWWQB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C339D","Version":"7.18.82"},{"DeviceName":"HPE Ethernet 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C18D3","Version":"7.18.82"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C1930","Version":"7.18.82"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C193A","Version":"7.18.82"},{"DeviceName":"HPE FlexFabric 10Gb 4-port 536FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-16A1159000EC","Version":"7.18.82"},{"DeviceName":"HPE NPAR 10Gb QP 536FLR-T","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-16A4159000EC","Version":"7.18.82"},{"DeviceName":"HPE StoreFabric CN1100R 10GBASE-T Dual Port Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E15908148","Version":"7.18.82"},{"DeviceName":"HPE StoreFabric CN1100R Dual Port Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C1931","Version":"7.18.82"},{"DeviceName":"HP NPAR 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C339D","Version":"7.18.82"},{"DeviceName":"HP NPAR 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C18D3","Version":"7.18.82"},{"DeviceName":"HP NPAR 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C193A","Version":"7.18.82"},{"DeviceName":"HP NPAR 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C1930","Version":"7.18.82"},{"DeviceName":"HP NPAR CN1100R Dual Port Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C1931","Version":"7.18.82"},{"DeviceName":"HPE NPAR 10Gb DP CN1100R-T","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE15908148","Version":"7.18.82"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic NX2 Gigabit Ethernet NICs Boot code (MFW), PXE, UEFI, iSCSI, FCoE, CCM and L2 code running under Linux x86_64 platform."},{"lang":"ja","x_late":"このパッケージには、Linux x86_64プラットフォームで動作するHPE ProLiant QLogic NX2 Gigabit Ethernet NICブートコード、MFW、PXE、UEFI、iSCSI、FCoE、CCMおよびL2コードをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains combo image v7.18.82&nbsp;with the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"2\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>NIC</strong></td>\n\t\t\t<td><strong>Boot Code Version</strong></td>\n\t\t\t<td><strong>PXE Version</strong></td>\n\t\t\t<td><strong>UEFI Version</strong></td>\n\t\t\t<td><strong>iSCSI Version</strong></td>\n\t\t\t<td><strong>FCoE Version</strong></td>\n\t\t\t<td><strong>CCM Version</strong></td>\n\t\t\t<td><strong>L2 Version</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HP Ethernet 10Gb 2-port 530SFP+ Adapter<br />\n\t\t\tHP Ethernet 10Gb 2-port 530T Adapter</td>\n\t\t\t<td>7.16.03</td>\n\t\t\t<td>7.14.13</td>\n\t\t\t<td>8.9.0</td>\n\t\t\t<td>n/a</td>\n\t\t\t<td>n/a</td>\n\t\t\t<td>7.14.4</td>\n\t\t\t<td>7.12.25</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>\n\t\t\t<p>HP Ethernet 10Gb 2-port 533FLR-T Adapter<br />\n\t\t\tHP FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter<br />\n\t\t\tHPE FlexFabric 10Gb 4-port 536FLR-T Adapter<br />\n\t\t\tHP StoreFabric CN1100R Dual Port Converged Network Adapter<br />\n\t\t\tHPE StoreFabric CN1100R-T Converged Network Adapter</p>\n\t\t\t</td>\n\t\t\t<td>7.16.03</td>\n\t\t\t<td>7.14.13</td>\n\t\t\t<td>8.9.0</td>\n\t\t\t<td>7.14.0</td>\n\t\t\t<td>7.14.3</td>\n\t\t\t<td>7.14.4</td>\n\t\t\t<td>7.12.25</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"3258441","datemodified":"2021-08-12T10:31:08","file_list":["./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.29.2-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.29.2-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.29.2-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.29.2-1.1/CP046934.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.29.2-1.1/CP046934.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.29.2-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.29.2-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.29.2-1.1/deps/libs/libqlgc_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.29.2-1.1/deps/libs/libtcl8.3.so","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.29.2-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.29.2-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.29.2-1.1/nic_fw/hp_mbi_7.18.82.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.29.2-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.29.2-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046934.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046934.scexe"],"md5sum":"52a6d3468b21780e106ff32b018213e0","name":"firmware-nic-qlogic-nx2-2.29.2-1.1.x86_64.rpm","release":"2021-08-12T10:21:20","revision":"0","sha1sum":"80c2de8379debc4ad9ac6d82ecfc2f4e69daa36f","size":"3MB","target_guids":["a6b1a447-382a-5a4f-14E4-168E103C339D","a6b1a447-382a-5a4f-14E4-168E103C18D3","a6b1a447-382a-5a4f-14E4-168E103C1930","a6b1a447-382a-5a4f-14E4-168E103C193A","a6b1a447-382a-5a4f-1077-16A1159000EC","a6b1a447-382a-5a4f-1077-16A4159000EC","a6b1a447-382a-5a4f-14E4-168E15908148","a6b1a447-382a-5a4f-14E4-168E103C1931","a6b1a447-382a-5a4f-14E4-16AE103C339D","a6b1a447-382a-5a4f-14E4-16AE103C18D3","a6b1a447-382a-5a4f-14E4-16AE103C193A","a6b1a447-382a-5a4f-14E4-16AE103C1930","a6b1a447-382a-5a4f-14E4-16AE103C1931","a6b1a447-382a-5a4f-14E4-16AE15908148"],"type_of_change":"1","version":"2.29.2"}],"id":{"product":"5f7dae044b3b4d97823b1cfc69305837","version":"8e6e5f6fdcf540a8901cb10b7857619b"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><em><strong>Steps to update the adapter firmware using the rpm pacakge:</strong></em></p>\n\n<ul>\n\t<li>Install the firmware rpm package:<br />\n\t<em>&gt; rpm -ivh &lt;rpm_filename&gt;.rpm </em></li>\n\t<li>Check where the files are extracted:<br />\n\t<em>&gt; rpm -qlp &lt;rpm_filename&gt;.rpm</em></li>\n\t<li>Using the output from the previous step determine the location of hpsetup file, change to that directory and run &#39;<em>./hpsetup</em>&#39; to update the firmware.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>Further information&nbsp;is available in CP046934.txt file.The results of the firmware upgrade are saved&nbsp;in CP046934.log at &quot;/var/cpq/.&quot;</li>\n\t<li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li>\n\t<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.&nbsp;</li>\n\t<li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware, it merely extracts the contents of the rpm package to the local system. Updating the adapter firmware requires following the steps outlined above.</li>\n</ul>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 Linux x86_64 的 HPE QLogic NX2 線上韌體升級公用程式"},{"lang":"en","x_late":"HPE QLogic NX2 Online Firmware Upgrade Utility for Linux x86_64"},{"lang":"ko","x_late":"Linux x86_64용 HPE QLogic NX2 온라인 펌웨어 업그레이드 유틸리티"},{"lang":"cn","x_late":"适用于 Linux x86_64 的 HPE QLogic NX2 在线固件升级实用程序"},{"lang":"ja","x_late":"HPE QLogic NX2オンラインファームウェアアップグレードユーティリティ for Linux x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"168E","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c339d","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c18d3","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1930","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c193a","type":"pci","ven":"14E4"},{"dev":"16A1","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a1159000ec","type":"pci","ven":"1077"},{"dev":"16A4","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a4159000ec","type":"pci","ven":"1077"},{"dev":"168E","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-168e15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1931","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c339d","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c193a","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1930","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1931","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ae15908148","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li><strong>This product addressed the firmware update failure problem which may cause NIC FW corruption.</strong></li>\n\t<li><strong>This product addressed the firmware update failure problem while the platform secure boot being enabled.</strong></li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 8 update 4 and SUSE Linux Enterprise Server 15 Service Pack 3</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"QLOGIC_NX2","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<br type=\"_moz\" />\n"}],"files":[{"bytes":"6994138","datemodified":"2021-05-17T22:57:34","file_list":["/CP047855.vmexe","/CP047855.vmfile","/CP047855.xml","/README.txt"],"md5sum":"93f58cde298611dcb16d3fe3f663e44f","name":"CP047855.zip","release":"2021-05-18T03:54:12","revision":"0","sha1sum":"16b2e32d5c7eaf0e79d5d63b8def789a49cd7558","size":"6MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021","vib_list":[]}],"id":{"product":"c4fb9c8ca4c44e82816b0b0a69f77b80","version":"2447f2627dbf4885a9c37a3c1914fca3"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component requires that the CRU driver be loaded before the component can run.</p>\n\n<p>The minimum CRU version for 5.1 is 5.0.3.9.<br />\nThe minimum CRU version for 5.5 is 5.5.4.1.<br />\nThe minimum CRU version for 6.0 is 6.0.8.<br />\nThe minimum CRU version for 6.5 is 6.5.8.<br />\nThe minimum CRU version for 6.7 is 6.7.10.<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>SPP Offline mode boots a special Linux OS environment, thus the Linux Components are used, not the VMware Components</li>\n</ul>\n\n<p><br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Download the appropriate SPP</li>\n\t<li>Add the component to the SPP</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run&nbsp; SUM</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps to complete the firmware update</li>\n\t<li>Refer to the SPP documentation for detailed instructions at:&nbsp; <a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Component ( CPxxxxxx.zip) in a temporary directory</li>\n\t<li>From the same directory, unzip the Component:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>To perform the standalone installation, execute the command:<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>Follow the directions given by the Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system for the firmware update to take effect</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、実行する前にCRUドライバーがロードされている必要があります。</p>\n\n<p>5.1の最小CRUバージョンは5.0.3.9です。<br />\n5.5の最小CRUバージョンは5.5.4.1です。<br />\n6.0の最小CRUバージョンは6.0.8です。<br />\n6.5の最小CRUバージョンは6.5.8です。<br />\n6.7の最小CRUバージョンは6.7.10です。<br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMwareコンポーネントではなく、Linuxコンポーネントが用いられます</li>\n</ul>\n\n<p><br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします</li>\n\t<li>SPPにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします</li>\n\t<li>SUMを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います</li>\n\t<li>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>コンポーネント (CPxxxxxx.zip)を一時ディレクトリに置きます</li>\n\t<li>同じディレクトリからコンポーネントをunzipします:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>スタンドアロンのインストールを行うために、次のコマンドを実行します：<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>コンポーネントの指示に従います</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n\t<li>システムを再起動し、ファームウェアのアップデートを有効にします</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware - HPE ProLiant DL60 Gen9/DL80 Gen9 (U15) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for VMware - HPE ProLiant DL60 Gen9/DL80 Gen9（U15）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"5","minor":"1","name":"VMware vSphere 5.1","platform":"vmware_esx_server","sr":"OEM"},{"major":"5","minor":"5","name":"VMware vSphere 5.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-05T03:54:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"}],"sw_keys":[{"name":"U15","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWFVK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATdsHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a5746564b","Version":"HPD4"},{"DeviceName":"MB006000JWFVL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATdsHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a5746564c","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB004000JWFVK and MB006000JWFVL"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB004000JWFVKおよびMB006000JWFVL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB004000JWFVK and MB006000JWFVL Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"16246945","datemodified":"2021-08-30T19:47:57","file_list":["/CP048320_BUILD_2.data","/CP048320.vmexe","/CP048320.vmexe64","/CP048320.vmfile","/CP048320_VMw.zip","/CP048320.xml","/payload.json","/CP048320_VMw.zip/index.xml","/CP048320_VMw.zip/vendor-index.xml","/CP048320_VMw.zip/metadata.zip","/CP048320_VMw.zip/vib20/CP048320/HPE_bootbank_CP048320_HPD4.2-7.0.0.15843807.vib","/CP048320_VMw.zip/metadata.zip/vendor-index.xml","/CP048320_VMw.zip/metadata.zip/vmware.xml","/CP048320_VMw.zip/metadata.zip/vibs/CP048320-6342785011101897965.xml","/CP048320_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048320_HPD4.2-7.0.0.15843807.xml"],"md5sum":"cf9165c04520ed9149a97eb4f7756dd5","name":"CP048320.zip","release":"2021-08-30T19:42:51","revision":"0","sha1sum":"7d68402bfafb305aa82c27e5a2b82ecc6542d40e","size":"15MB","target_guids":["4d2340a5-3042-3430-3030-304a5746564b","4d2340a5-3042-3630-3030-304a5746564c"],"type_of_change":"1","version":"HPD4","vib_list":[{"name":"CP048320","version":"HPD4.2-7.0.0.15843807"}]}],"id":{"product":"0e268c49682a427da167d2f123ccafaf","version":"dbe348f31daf45369b747ac1388713af"},"installation":{"command":"CP041749.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - MB004000JWFVK and MB006000JWFVL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi -MB004000JWFVKおよびMB006000JWFVLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB004000JWFVK","target_guid":"4d2340a5-3042-3430-3030-304a5746564b","type":"sas"},{"id":"MB006000JWFVL","target_guid":"4d2340a5-3042-3630-3030-304a5746564c","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-04T11:45:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>There is no compelling reason to update this firmware. Risk is that whoever looks at the Vendor ID in the VPD page will notice that it refers to HP instead of HPE. There is no functional risk if not upgraded.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB004000JWFVK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB006000JWFVL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE ProLiant Smart Array Px4x and Hx4x series controllers.  This RPM provides a customer friendly approach to install a pre-built binary driver.\nOn some kernel erratas the version of the driver present in the kernel may be equal to the version being installed by the rpm.  However, the driver in the kernel may not include all of the fixes and enhancements implemented in the driver contained within the rpm.  Therefore the rpm should be installed in order to obtain the fixes and enhancements that are not present in the kernel driver."},{"lang":"ja","x_late":"このRPMは、HPE ProLiant SmartアレイPx4xおよびHx4xシリーズコントローラーを有効にするためのプレビルドバイナリドライバーモジュールを提供します。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。errataカーネルによっては、カーネル内に存在するドライバーのバージョンとrpmによってインストールされたバージョンが等しい場合があります。だたし、カーネル内のドライバーは、rpmに含まれるドライバーに対して行われた、すべての修正と拡張が含まれていないことがあります。そのため、rpmはカーネルドライバーに存在しない、修正と拡張を入手するため、インストールする必要があります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"76598","datemodified":"2021-07-01T17:47:31","file_list":["./etc/dracut.conf.d/hpsa.conf","./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/hpsa.ko","./usr/share/smartupdate/hpsa-kmp-default/component.xml"],"md5sum":"2a88f6bf7a7de7c4f592243bec7e80ce","name":"hpsa-kmp-default-3.4.20-210.sles15sp2.x86_64.rpm","release":"2021-07-01T17:39:05","revision":"0","sha1sum":"c0b84288b0d74f581fedff7be5d27687c281b43d","size":"74KB","target_guids":[],"type_of_change":"1","version":"3.4.20-210"},{"bytes":"76639","datemodified":"2021-07-01T17:51:50","file_list":["./etc/dracut.conf.d/hpsa.conf","./lib/modules/5.3.18-57-default","./lib/modules/5.3.18-57-default/updates","./lib/modules/5.3.18-57-default/updates/hpsa.ko","./usr/share/smartupdate/hpsa-kmp-default/component.xml"],"md5sum":"adefe6763774dcbfe4a7d511d14b5295","name":"hpsa-kmp-default-3.4.20-210.sles15sp3.x86_64.rpm","release":"2021-07-01T17:39:05","revision":"0","sha1sum":"aeb2ebfe1b66f257990ee59479b89529c35d97ce","size":"74KB","target_guids":[],"type_of_change":"1","version":"3.4.20-210"}],"id":{"product":"4f235836a2c34b2fb5610223cd1b694c","version":"0201aaf9ae3441469dadf857dde36670"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as the system administrator (root), download the RPM to a directory on<br />\nyour hard drive and change to that directory.</p>\n\n<p><strong>To install or upgrade&nbsp;the driver type:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li># rpm -Uvh hpsa-kmp-default-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm&nbsp;&nbsp;</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p style=\"margin-right:0px\">Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p><strong>NOTE</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:</p>\n\n<ul>\n\t<li># rpm -e hpsa-kmp-default-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</li>\n</ul>\n\n<p><strong><u>Enterprise Support</u></strong><br />\nFor support on Smart Array controllers, visit <a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a></p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>システム管理者（root）としてログインし、RPMを<br />\nご使用のハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</p>\n\n<p><strong>ドライバーをインストールまたはアップグレードするには次のようにタイプします。</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li># rpm -Uvh hpsa-kmp-default-<version>.<OSupdate>.x86_64.rpm  </li>\n</ul>\n\n<p> </p>\n\n<p style=\"margin-right:0px\">Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p><strong>注記：</strong>インストールの失敗、あるいは警告やエラーメッセージを表示して停止した場合は、コンピューターを再起動しないでください。ドライバーは動作しないため、以下のコマンドをタイプしてアンインストールしてください。</p>\n\n<ul>\n\t<li># rpm -e hpsa-kmp-default-<version>.<OSupdate>.x86_64.rpm</li>\n</ul>\n\n<p><strong><u>Enterprise Support</u></strong><br />\nSmartアレイコントローラーのサポートに関しては、<a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a>を参照してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE ProLiant Smart Array Controller (64-bit) Driver for SUSE LINUX Enterprise Server 15 (64-bit)"},{"lang":"ja","x_late":"SUSE LINUX Enterprise Server 15(64-bit)用HPE ProLiant Smartアレイコントローラー(64-bit)ドライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"323c","subdev":"1928","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21BD","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ca","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1922","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1923","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c2","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c0","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c3","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1926","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21be","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3353","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1924","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1921","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cb","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c1","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c5","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21CD","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cc","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3355","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3350","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3351","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3354","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3352","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323B","subdev":"3356","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3239","subdev":"21c7","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21bf","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c8","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c6","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ce","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T12:16:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Add support for SUSE Linux Enterprise Services 15 SP2</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Add support for SUSE Linux Enterprise Services 15 SP3</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P74","value":"HP ProLiant SL140s Gen8 Server (private)"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 v2 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"P83","value":"HP ProLiant SL210t Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I14","value":"HP ProLiant BL480c Server"}],"sw_keys":[{"name":"hpsa-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hpsa-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hpsa-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hpsa-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains be2net drivers for the HPE Blade Emulex 10/20GbE Server Adapters running under Red Hat Enterprise Linux 7."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7で動作するHPE Blade Emulex 10/20GbE サーバーアダプター用のbe2netドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"100964","datemodified":"2021-03-08T18:02:04","file_list":["./etc/depmod.d/be2net.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/be2net","./lib/modules/3.10.0-1160.el7.x86_64/extra/be2net/be2net.ko","./usr/share/smartupdate/kmod-be2net_bl/component.xml"],"md5sum":"7d01d1f1d7997fdf297c2e45190cb822","name":"kmod-be2net_bl-12.0.1342.0-1.rhel7u9.x86_64.rpm","release":"2021-03-08T17:52:14","revision":"0","sha1sum":"01cac2c76a503b9065e5455abd6888535fab2e6a","size":"98KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec04f7105f"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"100969","datemodified":"2021-03-08T17:59:24","file_list":["./etc/depmod.d/be2net.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/be2net","./lib/modules/3.10.0-1127.el7.x86_64/extra/be2net/be2net.ko","./usr/share/smartupdate/kmod-be2net_bl/component.xml"],"md5sum":"d006b6949e0a390a0252a4f6b56629d2","name":"kmod-be2net_bl-12.0.1342.0-1.rhel7u8.x86_64.rpm","release":"2021-03-08T17:52:14","revision":"0","sha1sum":"105f32e3b2493ef3a74fc1642d2fee9f46a557fc","size":"98KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec04f7105f"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"2d95bd349a5f487bbf7bbf3c783e4857","version":"2518ca8f7bf64c0180e2fcefe647aa86"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE Drivers for Red Hat Enterprise Linux 7"},{"lang":"ja","x_late":"HPE Blade Emulex 10/20GbEドライバーfor Red Hat Enterprise Linux 7"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0728","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c1935","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c1934","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 7 Update 8 and Red Hat Enterprise Linux 7 Update 9.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 7, Updates 8 and 9.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"kmod-be2net_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2net_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2net_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2net_bl","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JWAYK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHsseFD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a5741594b","Version":"HPD6"},{"DeviceName":"MB008000JWAYH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHsseFD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57415948","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB010000JWAYK and MB008000JWAYH"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： MB010000JWAYKおよびMB008000JWAYH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB010000JWAYK and MB008000JWAYH Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"4210120","datemodified":"2021-07-23T11:31:27","file_list":["cp048672.xml","cpqsetup.exe","HLIBRHsseFD6.rel","payload.json","setup.dll"],"md5sum":"28ebbf4f18cae52ab28fe02e7269af80","name":"cp048672.exe","release":"2021-07-23T11:24:07","revision":"0","sha1sum":"92281966b0ac4f31c7db909ba5984a312b1a28e6","size":"4MB","target_guids":["4d2340a5-3042-3031-3030-304a5741594b","4d2340a5-3042-3830-3030-304a57415948"],"type_of_change":"1","version":"HPD6"}],"id":{"product":"e4254455513a49c0ad5f61c79ab13950","version":"e63c7e2329af4981a3dd741c7b6e7f21"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB010000JWAYK and MB008000JWAYH Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB010000JWAYKおよびMB008000JWAYHドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB010000JWAYK","target_guid":"4d2340a5-3042-3031-3030-304a5741594b","type":"sas"},{"id":"MB008000JWAYH","target_guid":"4d2340a5-3042-3830-3030-304a57415948","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-17T08:29:26","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000JWAYH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB010000JWAYK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MT001600KWHAC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPS1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3130-3630-304b57484143","Version":"HPS1"},{"DeviceName":"MT003200KWHAD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPS1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3330-3230-304b57484144","Version":"HPS1"},{"DeviceName":"MT006400KWHAE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPS1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3630-3430-304b57484145","Version":"HPS1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MT001600KWHAC, MT003200KWHAD and MT006400KWHAE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD Flash Component for&nbsp;Windows (x64) - &nbsp;MT001600KWHAC, MT003200KWHAD and MT006400KWHAE Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPS1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>\n"}],"files":[{"bytes":"5046048","datemodified":"2021-07-24T11:15:20","file_list":["cp048480.xml","cpqsetup.exe","HPS1.rel","payload.json","setup.dll"],"md5sum":"e64a9fe7203918477a898edb678e065b","name":"cp048480.exe","release":"2021-07-24T11:07:04","revision":"0","sha1sum":"07f6e05e2005f5ed7c3d223218218bf624bd4731","size":"4MB","target_guids":["4d2340a5-3054-3130-3630-304b57484143","4d2340a5-3054-3330-3230-304b57484144","4d2340a5-3054-3630-3430-304b57484145"],"type_of_change":"1","version":"HPS1"}],"id":{"product":"81163fed551c4f30a0af9ef8c5746c3e","version":"da114807caf045e2bf00345b0d7083bc"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\<SPP root folder>\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリに配置します。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) -  MT001600KWHAC, MT003200KWHAD and MT006400KWHAE Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - MT001600KWHAC、MT003200KWHAD、およびMT006400KWHAEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MT006400KWHAE","target_guid":"4d2340a5-3054-3630-3430-304b57484145","type":"nvme"},{"id":"MT003200KWHAD","target_guid":"4d2340a5-3054-3330-3230-304b57484144","type":"nvme"},{"id":"MT001600KWHAC","target_guid":"4d2340a5-3054-3130-3630-304b57484143","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T18:42:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MT003200KWHAD","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT001600KWHAC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT006400KWHAE","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component provides 64-bit Microsoft Windows Server 2012 R2, 2016, and 2019 editions support for the HPE Smart Array SAS/SATA Controllers."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"641552","datemodified":"2021-07-07T07:00:46","file_list":["cp048869.xml","cpqsetup.exe","generic.dll","hpcisss3.cat","HpCISSs3.inf","HpCISSs3.sys","install.xml"],"md5sum":"fd1bfad395db11b1cb0ec3ee66a3e131","name":"cp048869.exe","release":"2021-07-07T06:59:05","revision":"0","sha1sum":"ea699608870c3c7a09362cd2016497907ac45bf8","size":"626KB","target_guids":[],"type_of_change":"1","version":"106.26.0.64"}],"id":{"product":"32cb58a13b764af9aba40956dbeca3b6","version":"0edc0d10de0441f18d0886ae74774ac5"},"installation":{"command":"cpqsetup.exe","command_params":"/verbose_log","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"tw","x_late":"將智慧型元件下載至硬碟上的目錄，並變更至該目錄。下載的檔案為自我解壓縮的可執行檔，其檔名包含智慧型元件編號。 <br><p>從該磁碟和目錄，執行下載的檔案。"},{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number. <br><p>From that drive and directory, execute the downloaded file."},{"lang":"ko","x_late":"스마트 구성 요소를 하드 드라이브의 디렉터리로 다운로드하고 그 디렉터리로 이동합니다. 다운로드한 파일은 스마트 구성 요소 번호에 따라 파일 이름이 지정된 자동 압축 풀기 실행 파일입니다. <br><p>드라이브와 디렉터리에서 다운로드한 파일을 실행합니다."},{"lang":"cn","x_late":"将智能组件下载到硬盘目录中，然后转至该目录。下载的文件是一个自解压可执行文件，其文件名基于 Smart Component 编号命名。 <br><p>在该硬盘目录中，执行下载的文件。"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスク ドライブにダウンロードし、そのディレクトリに移動します。 ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。 <br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE ProLiant Smart Array HPCISSS3 Controller Driver for 64-bit Microsoft Windows Server 2012 R2/2016/2019 Editions"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"323c","subdev":"1928","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21BD","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ca","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1922","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1920","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1923","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c2","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c0","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c3","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1926","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21be","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3353","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1924","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1921","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1925","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cb","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c1","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c5","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21CD","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cc","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3355","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3350","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3351","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3354","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3352","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323B","subdev":"3356","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3239","subdev":"21c7","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21bf","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c8","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c6","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ce","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows 8 (64-bit)","platform":"nt-x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows 8.1 (64-bit)","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-06T13:42:04","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>System could potentially&nbsp;display a BSOD while executing a hot replace due to a memory aligment problem</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>System could potentially&nbsp;display a BSOD while executing a hot replace due to a memory aligment problem</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"A31","value":"HP ProLiant SL4545 G7 Server"},{"key":"J06","value":"HP ProLiant MicroServer Gen8"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P74","value":"HP ProLiant SL140s Gen8 Server (private)"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"R02","value":"HP X1600 Network Storage System"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A29","value":"HP ProLiant DL585 Gen8 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P78","value":"HP ProLiant ML310e Gen8 v2 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"hpcisss3.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5911128","datemodified":"2021-05-18T04:19:39","file_list":["SignedImageInstaller64.dll","U19_2.90_04_29_2021.signed.flash","cp047847.xml","cpqsetup.exe","cpqsysio64.sys"],"md5sum":"cf18c2e95cabe4604c2696be0250b122","name":"cp047847.exe","release":"2021-05-18T04:03:06","revision":"0","sha1sum":"b6e0598eaee2ad786fcb5bd77513b63c2585da17","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021"}],"id":{"product":"9f645709728442bbae04d049c43912b7","version":"4e89e4a7440e4bd28f72f82ddc29431a"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE Apollo 4200 Gen9/HPE ProLiant XL420 Gen9 (U19) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント  for Windows x64 - HPE Apollo 4200 Gen9/HPE ProLiant XL420 Gen9 (U19) サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-05T03:47:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","latest_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390.  These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U19","value":"HPE ProLiant XL420 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"}],"sw_keys":[{"name":"U19","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The HPE Agentless Management Service (hp-ams) provides support for HPE Integrated Lights-Out 4 (HPE iLO 4) Embedded Health and Alerting."},{"lang":"ja","x_late":"HPE Agentless Management Service（hp-ams）は、HPE Integrated Lights Out 4（HPE iLO 4）内蔵ヘルスおよびアラートのサポートを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Diagnosing connection issues:</strong></p>\n\n<p>Verify that the HPE iLO 4 is talking to SNMP from a Linux system with net-snmp utilities installed:</p>\n\n<p style=\"margin-left:40px\"><em>snmpwalk -t 60 -v 2c -Ox -c</em> <strong>iLO4_configured_community_string</strong> <strong>iLO4_IP_Address</strong>&nbsp;<em>1.3.6.1.4.1.232.1.1</em></p>\n\n<p>Verify that HPE AMS is operating on the Server:</p>\n\n<p style=\"margin-left:40px\"><em>snmpwalk -t 60 -v 2c -Ox -c</em> <strong>iLO4_configured_community_string</strong> <strong>iLO4_IP_Address</strong>&nbsp;<em>1.3.6.1.4.1.232.5.1</em></p>\n"},{"lang":"ja","x_late":"<p><strong>接続の問題の診断：</strong></p>\n\n<p>HPE iLO 4が、net-snmpユーティリティがインストールされたLinuxシステムから、SNMPに通信していることを確認：</p>\n\n<p style=\"margin-left:40px\"><em>snmpwalk -t 60 -v 2c -Ox -c</em> <strong>iLO4_configured_community_string</strong> <strong>iLO4_IP_Address</strong> <em>1.3.6.1.4.1.232.1.1</em></p>\n\n<p>サーバー上でHPE AMSが動作していることを確認：</p>\n\n<p style=\"margin-left:40px\"><em>snmpwalk -t 60 -v 2c -Ox -c</em> <strong>iLO4_configured_community_string</strong> <strong>iLO4_IP_Address</strong> <em>1.3.6.1.4.1.232.5.1</em></p>\n"}],"files":[{"bytes":"716024","datemodified":"2021-10-06T05:18:31","file_list":["./etc/sysconfig/hp-ams","./opt/hp/hp-ams","./opt/hp/hp-ams/hp-ams.license","./sbin/amsHelper","./usr/lib/systemd/system/hp-ams.service","./usr/share/man/man8/amsHelper.8.gz","./usr/share/smartupdate/hp-ams/component.xml"],"md5sum":"1e00debfa974d9b23f3afd8670870204","name":"hp-ams-2.10.4-885.4.sles12.x86_64.rpm","release":"2021-10-06T05:07:15","revision":"0","sha1sum":"9f43977410152ab64a1ed84a5fedaccc891d002c","size":"699KB","target_guids":[],"type_of_change":"0","version":"2.10.4"}],"id":{"product":"ce9d04fe2b3e43e88c77633c663ce12b","version":"8a185dbd5c4c4f479e0a1a1251aacb68"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"","SubRequirements":[]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>To install the package type:</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;rpm -ivh hp-ams-&lt;version&gt;.rpm</p>\n\n<p>To check whether the package is loaded properly type:</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;systemctl status hp-ams</p>\n\n<p>Additional help is available by typing:</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;man amshelper</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 SUSE LINUX Enterprise Server 12 的 HPE ProLiant 無代理程式管理服務"},{"lang":"en","x_late":"HPE ProLiant Agentless Management Service for SUSE LINUX Enterprise Server 12"},{"lang":"ko","x_late":"SUSE LINUX Enterprise Server 12용 HPE ProLiant Agentless 관리 서비스"},{"lang":"cn","x_late":"用于SUSE LINUX企业级服务器12的HPE ProLiant无代理管理服务"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"id":"5219994","target_guid":"","type":"other"},{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3300","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3302","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-21T13:30:38","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>Addressed&nbsp;a small amount of memory leak as documented in the Customer Advisory, <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00053824en_us\" style=\"color:#0563c1; text-decoration:underline\">a00053824en_us</a></li>\n\t<li>&nbsp;NVMe drive information is now available in the CPQSE.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>Drive&nbsp;status all shows failed on SL4540 Gen8 H220 [LSI] ILO4 due to&nbsp; incorrect SCSI command tags.</li>\n\t<li>Addressed issue where hp-ams may fail to start when&nbsp;U.3 NVMe devices are installed in the system</li>\n\t<li>The HPE Synergy 6810C 25/50Gb Ethernet Adapter not displaying information in hp-ams is now resolved</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"J06","value":"HP ProLiant MicroServer Gen8"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 v2 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P78","value":"HP ProLiant ML310e Gen8 v2 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"}],"sw_keys":[{"name":"hp-ams","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VR000150GWEPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDMHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3135-304757455050","Version":"HPG1"},{"DeviceName":"VR000480GWEPR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDMHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3438-304757455052","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VR000150GWEPP and VR000480GWEPR"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- VR000150GWEPP and VR000480GWEPR Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Fixes an issue which caused the drive to become non-functional.</li>\n\t<li>Fixes VPD Log D0h reported drive Sanitize times.</li>\n\t<li>Adds support for Security Log Page BBh</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4703297","datemodified":"2021-07-23T09:10:09","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b7eb905efe-HPG1-7.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-b7eb905efe-HPG1-7.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b7eb905efe-HPG1-7.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b7eb905efe-HPG1-7.1/4IDMHPG1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-b7eb905efe-HPG1-7.1/CP048197.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b7eb905efe-HPG1-7.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b7eb905efe-HPG1-7.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b7eb905efe-HPG1-7.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b7eb905efe-HPG1-7.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048197.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048197.scexe"],"md5sum":"579a2bc1b3ec3c6be68c68b35d34cae6","name":"firmware-hdd-b7eb905efe-HPG1-7.1.x86_64.rpm","release":"2021-07-23T08:57:09","revision":"0","sha1sum":"c75f175a67575e09486919d5ed79289dfc5cbd1f","size":"4MB","target_guids":["562340a5-3052-3030-3135-304757455050","562340a5-3052-3030-3438-304757455052"],"type_of_change":"2","version":"HPG1"}],"id":{"product":"221cbeaf26c845fea3e521bf7ae66fa1","version":"7c789edd067c43e9800f83fcab4ab563"},"installation":{"command":"CP040348.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VR000150GWEPP and VR000480GWEPR Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VR000150GWEPPおよびVR000480GWEPRドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VR000480GWEPR","target_guid":"562340a5-3052-3030-3438-304757455052","type":"sata"},{"id":"VR000150GWEPP","target_guid":"562340a5-3052-3030-3135-304757455050","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T10:56:09","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Fixes an issue which caused the drive to become non-functional.</li>\n\t<li>Fixes VPD Log D0h reported drive Sanitize times.</li>\n\t<li>Adds support for Security Log Page BBh.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Fixes an issue which caused the drive to become non-functional.</li>\n\t<li>Fixes VPD Log D0h reported drive Sanitize times.</li>\n\t<li>Adds support for Security Log Page BBh.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VR000480GWEPR","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VR000150GWEPP","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JWAYK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHsseFD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a5741594b","Version":"HPD6"},{"DeviceName":"MB008000JWAYH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHsseFD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57415948","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB010000JWAYK and MB008000JWAYH"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： MB010000JWAYKおよびMB008000JWAYH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB010000JWAYK and MB008000JWAYH Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"6083828","datemodified":"2021-07-23T08:05:21","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-6ec35faf90-HPD6-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-6ec35faf90-HPD6-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-6ec35faf90-HPD6-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6ec35faf90-HPD6-2.1/CP048136.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-6ec35faf90-HPD6-2.1/HLIBRHsseFD6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-6ec35faf90-HPD6-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6ec35faf90-HPD6-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-6ec35faf90-HPD6-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-6ec35faf90-HPD6-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048136.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048136.scexe"],"md5sum":"a11f848d392f7845f92d6c7b460b130d","name":"firmware-hdd-6ec35faf90-HPD6-2.1.x86_64.rpm","release":"2021-07-23T07:52:08","revision":"0","sha1sum":"8965c06c7424e5faee075c4230dd4a8e3a7fde6a","size":"5MB","target_guids":["4d2340a5-3042-3031-3030-304a5741594b","4d2340a5-3042-3830-3030-304a57415948"],"type_of_change":"1","version":"HPD6"}],"id":{"product":"21c2460d0eda43ee8d9561eb3baf6bcd","version":"d4c9001ad60341c5a4782815892a0715"},"installation":{"command":"CP040326.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB010000JWAYK and MB008000JWAYH Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB010000JWAYKおよびMB008000JWAYHドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB010000JWAYK","target_guid":"4d2340a5-3042-3031-3030-304a5741594b","type":"sas"},{"id":"MB008000JWAYH","target_guid":"4d2340a5-3042-3830-3030-304a57415948","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-26T12:00:58","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000JWAYH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB010000JWAYK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000JWDFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEAHssseFD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57444644","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB012000JWDFD"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB012000JWDFD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB012000JWDFD Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"6028268","datemodified":"2021-07-23T08:02:36","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD3-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD3-2.1/CP048140.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD3-2.1/HLEAHssseFD3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD3-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048140.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048140.scexe"],"md5sum":"a783c3655588a6eeda1f03320f72a5f7","name":"firmware-hdd-aaf1014ede-HPD3-2.1.x86_64.rpm","release":"2021-07-23T07:50:12","revision":"0","sha1sum":"34cedd66b9a70a89632d34848c90a2eb0984bd4a","size":"5MB","target_guids":["4d2340a5-3042-3231-3030-304a57444644"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"421cc08cc7bc4143866089180c719d3f","version":"1a03f51f4a224fe28f961f51e7b31394"},"installation":{"command":"CP040338.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB012000JWDFD Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB012000JWDFDドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB012000JWDFD","target_guid":"4d2340a5-3042-3231-3030-304a57444644","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-26T18:07:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB012000JWDFD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ED6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e52","Version":"HPD6"},{"DeviceName":"EG002400JWJNT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ED6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e54","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EG001800JWJNR and EG002400JWJNT"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EG001800JWJNRおよびEG002400JWJNT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG001800JWJNR and EG002400JWJNT Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"18695036","datemodified":"2021-08-30T04:28:31","file_list":["/CP048254_BUILD_2.data","/CP048254.vmexe","/CP048254.vmexe64","/CP048254.vmfile","/CP048254_VMw.zip","/CP048254.xml","/payload.json","/CP048254_VMw.zip/index.xml","/CP048254_VMw.zip/vendor-index.xml","/CP048254_VMw.zip/metadata.zip","/CP048254_VMw.zip/vib20/CP048254/HPE_bootbank_CP048254_HPD6.2-7.0.0.15843807.vib","/CP048254_VMw.zip/metadata.zip/vendor-index.xml","/CP048254_VMw.zip/metadata.zip/vmware.xml","/CP048254_VMw.zip/metadata.zip/vibs/CP048254-1748087930984269899.xml","/CP048254_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048254_HPD6.2-7.0.0.15843807.xml"],"md5sum":"56ed0b6c39c347d6ea03cd70f50e23ba","name":"CP048254.zip","release":"2021-08-30T04:23:07","revision":"0","sha1sum":"975b4b9658f855f1692d20727ff1dc069c369261","size":"17MB","target_guids":["452340a5-3047-3130-3830-304a574a4e52","452340a5-3047-3230-3430-304a574a4e54"],"type_of_change":"1","version":"HPD6","vib_list":[{"name":"CP048254","version":"HPD6.2-7.0.0.15843807"}]}],"id":{"product":"58058fc7c39a49caa2844dbe139ab3f9","version":"10b023cb6a744ca7871db201b4c5029b"},"installation":{"command":"CP042785.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - EG001800JWJNR and EG002400JWJNT Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - EG001800JWJNRおよびEG002400JWJNTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG001800JWJNR","target_guid":"452340a5-3047-3130-3830-304a574a4e52","type":"sas"},{"id":"EG002400JWJNT","target_guid":"452340a5-3047-3230-3430-304a574a4e54","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-02T08:42:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG002400JWJNT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG001800JWJNR","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWFUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SELD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a57465556","Version":"HPD4"},{"DeviceName":"EG001200JWFVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SELD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3230-304a57465641","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG000600JWFUV and EG001200JWFVA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG000600JWFUV and&nbsp;EG001200JWFVA&nbsp;Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"4768691","datemodified":"2021-07-23T08:36:55","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-f0c91d2fe3-HPD4-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-f0c91d2fe3-HPD4-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-f0c91d2fe3-HPD4-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-f0c91d2fe3-HPD4-2.1/CP048063.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-f0c91d2fe3-HPD4-2.1/T14SELD4.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-f0c91d2fe3-HPD4-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-f0c91d2fe3-HPD4-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-f0c91d2fe3-HPD4-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-f0c91d2fe3-HPD4-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048063.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048063.scexe"],"md5sum":"2942f97acf3ff641ff52bcc8b5883b9f","name":"firmware-hdd-f0c91d2fe3-HPD4-2.1.x86_64.rpm","release":"2021-07-23T08:25:06","revision":"0","sha1sum":"5a5407fd75175ac2b7eac26859f78932ebf3b04c","size":"4MB","target_guids":["452340a5-3047-3030-3630-304a57465556","452340a5-3047-3130-3230-304a57465641"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"0d53f18d93f34c14a12850b4c4f5646a","version":"00fdf1adb672473e93675e958c607d8f"},"installation":{"command":"CP040324.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64)  - EG000600JWFUV and EG001200JWFVA Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - EG000600JWFUVおよびEG001200JWFVAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EG001200JWFVA","target_guid":"452340a5-3047-3130-3230-304a57465641","type":"sas"},{"id":"EG000600JWFUV","target_guid":"452340a5-3047-3030-3630-304a57465556","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-21T09:44:04","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>A low-probability, high severity corner case of sustained outer-diameter activity with emergency power off when heads are at the outer diameter prevented heads from parking/latching properly on a few drives in the field.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001200JWFVA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG000600JWFUV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JWZHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a575a4841","Version":"HPD2"},{"DeviceName":"MB012000JWZHB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a575a4842","Version":"HPD2"},{"DeviceName":"MB014000JWZHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a575a4843","Version":"HPD2"},{"DeviceName":"MB016000JWZHE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a575a4845","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) -&nbsp;MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4117168","datemodified":"2021-07-26T06:32:30","file_list":["cp049052.xml","cpqsetup.exe","payload.json","setup.dll","SHPEEVANSSD2.rel"],"md5sum":"656f691714d52ba8644fa99b9e61082b","name":"cp049052.exe","release":"2021-07-26T06:24:07","revision":"0","sha1sum":"2e7a35d98cd577efbc698cdf5053b77efc185481","size":"3MB","target_guids":["4d2340a5-3042-3031-3030-304a575a4841","4d2340a5-3042-3231-3030-304a575a4842","4d2340a5-3042-3431-3030-304a575a4843","4d2340a5-3042-3631-3030-304a575a4845"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"a25f1000baab4c289a20555c0f1143b1","version":"634ba474b82a41b5ad801db22f5b4de8"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB010000JWZHA","target_guid":"4d2340a5-3042-3031-3030-304a575a4841","type":"sas"},{"id":"MB012000JWZHB","target_guid":"4d2340a5-3042-3231-3030-304a575a4842","type":"sas"},{"id":"MB014000JWZHC","target_guid":"4d2340a5-3042-3431-3030-304a575a4843","type":"sas"},{"id":"MB016000JWZHE","target_guid":"4d2340a5-3042-3631-3030-304a575a4845","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-20T10:26:29","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB010000JWZHA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB016000JWZHE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB012000JWZHB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB014000JWZHC","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"tw","x_late":"此適用於 Linux 的 HPE System Management Homepage (系統管理首頁) 範本 (hp-smh-templates) 包含適用於伺服器、管理處理器、NIC 與儲存子系統的 System Management Homepage 範本。此範本匯集了 html、javascript 與 php 檔案，可作為圖形使用者介面以顯示由各個子系統代理程式所提供的許多 SNMP 資料。所以此套件是相依於 hp-snmp-agents 套件。此套件也相依於 hpsmh 套件以將頁面提供給瀏覽器。   "},{"lang":"en","x_late":"This HPE System Management Homepage Templates for Linux (hp-smh-templates) contains the System Management Homepage Templates for Server, Management processor, NIC and Storage subsystems. The templates are a collection of html, javascript and php files that act as a GUI to display much of the SNMP data provided by each subsystems agent(s). As such this package is dependant on the hp-snmp-agents package. This package is also dependant on the hpsmh package to serve the pages to the browser.   "},{"lang":"ko","x_late":"Linux용 HPE System Management Homepage 템플릿(hp-smh-templates)에는 서버, 관리 프로세서, NIC 및 스토리지 하위 시스템용 System Management Homepage 템플릿이 포함됩니다. 템플릿은 각 하위 시스템 에이전트에서 제공하는 많은 SNMP 데이터를 표시하기 위한 GUI의 역할을 하는 html, javascript 및 php 파일의 컬렉션입니다. 따라서 이 패키지는 hp-snmp-agents 패키지에 따라 다릅니다. 또한, 이 패키지는 브라우저에 페이지를 제공하기 위한 hpsmh 패키지에 따라서도 다릅니다.   "},{"lang":"cn","x_late":"此HPE System Management Homepage Templates for Linux (hp-smh-templates) 包含适用于服务器、管理处理器、NIC 和存储子系统的系统管理主页模板。这些模板包括 html、javascript 和 php 文件，可作为 GUI 显示每个子系统代理程序提供的大部分 SNMP 数据。同样，该软件包也依赖于 hp-snmp-agents 软件包。此外，该软件包还依赖于 hpsmh 软件包为浏览器提供页面。   "},{"lang":"ja","x_late":"サーバー、マネジメントプロセッサー、NIC、およびストレージ サブシステム用のHPE System Management Homepageテンプレート for Linux （hp-smh-templates）には、サーバーのSystem Management Homepageテンプレート、マネジメントプロセッサー、NIC、およびストレージ サブシステムが含まれています。 テンプレートは、各サブシステムエージェントで提供される多くのSNMPデータを表示させるためのGUI として機能するhtml、javascript、およびphpファイルの集まりです。 このパッケージ自体は、hp-snmp-agentsパッケージに含まれるものです。 このパッケージは、ブラウザーにページを提供するためのhpsmhパッケージにも含まれています。   "}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[{"lang":"en","x_late":null}],"files":[{"bytes":"3618471","datemodified":"2019-02-21T02:39:26","file_list":["./opt/hp/hp-smh-templates","./opt/hp/hp-smh-templates/bin","./opt/hp/hp-smh-templates/bin/add-sudo-entries","./opt/hp/hp-smh-templates/bin/del-sudo-entries","./opt/hp/hp-smh-templates/hp-smh-templates.license","./opt/hp/hp-smh-templates/hprpm.xpm","./opt/hp/hpsmh/data/cgi-bin/snmpagent","./opt/hp/hpsmh/data/cgi-bin/snmpagent/SetSNMPData.cgi","./opt/hp/hpsmh/data/cgi-bin/snmpagent/SetSNMPData.cgis","./opt/hp/hpsmh/data/htdocs/ginkgotest","./opt/hp/hpsmh/data/htdocs/ginkgotest/csginkgotest.php.en","./opt/hp/hpsmh/data/htdocs/hmanics","./opt/hp/hpsmh/data/htdocs/hmanics/common","./opt/hp/hpsmh/data/htdocs/hmanics/common/compaq.js.en","./opt/hp/hpsmh/data/htdocs/hmanics/common/compaq.js.ja","./opt/hp/hpsmh/data/htdocs/hmanics/common/cond.js.en","./opt/hp/hpsmh/data/htdocs/hmanics/common/cond.js.ja","./opt/hp/hpsmh/data/htdocs/hmanics/common/dispbase.js.en","./opt/hp/hpsmh/data/htdocs/hmanics/common/dispbase.js.ja","./opt/hp/hpsmh/data/htdocs/hmanics/common/helputil.js.en","./opt/hp/hpsmh/data/htdocs/hmanics/common/helputil.js.ja","./opt/hp/hpsmh/data/htdocs/hmanics/common/navtable.js","./opt/hp/hpsmh/data/htdocs/hmanics/common/numcnvrt.js","./opt/hp/hpsmh/data/htdocs/hmanics/common/pagetags.htm.en","./opt/hp/hpsmh/data/htdocs/hmanics/common/pagetags.htm.ja","./opt/hp/hpsmh/data/htdocs/hmanics/common/pagetags.php.en","./opt/hp/hpsmh/data/htdocs/hmanics/common/pagetags.php.ja","./opt/hp/hpsmh/data/htdocs/hmanics/common/parsearg.js.en","./opt/hp/hpsmh/data/htdocs/hmanics/common/parsearg.js.ja","./opt/hp/hpsmh/data/htdocs/hmanics/common/setitem.php.en","./opt/hp/hpsmh/data/htdocs/hmanics/common/setitem.php.ja","./opt/hp/hpsmh/data/htdocs/hmanics/common/setmsgs.php.en","./opt/hp/hpsmh/data/htdocs/hmanics/common/setmsgs.php.ja","./opt/hp/hpsmh/data/htdocs/hmanics/common/sets.js.en","./opt/hp/hpsmh/data/htdocs/hmanics/common/sets.js.ja","./opt/hp/hpsmh/data/htdocs/hmanics/common/sorts.js.en","./opt/hp/hpsmh/data/htdocs/hmanics/common/sorts.js.ja","./opt/hp/hpsmh/data/htdocs/hmanics/common/stditems.js.en","./opt/hp/hpsmh/data/htdocs/hmanics/common/stditems.js.ja","./opt/hp/hpsmh/data/htdocs/hmanics/common/swtable.js.en","./opt/hp/hpsmh/data/htdocs/hmanics/common/swtable.js.ja","./opt/hp/hpsmh/data/htdocs/hmanics/common/tables.js","./opt/hp/hpsmh/data/htdocs/hmanics/dt5enums.js.en","./opt/hp/hpsmh/data/htdocs/hmanics/dt5enums.js.ja","./opt/hp/hpsmh/data/htdocs/hmanics/help","./opt/hp/hpsmh/data/htdocs/hmanics/help/IMA00010.htm.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/IMA00201.htm.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/IMA00202.htm.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/IMA00203.htm.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/IMA00204.htm.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/IMA00205.htm.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/NicAg.htm.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/TOPARROW.gif","./opt/hp/hpsmh/data/htdocs/hmanics/help/default.css","./opt/hp/hpsmh/data/htdocs/hmanics/help/default_ns.css","./opt/hp/hpsmh/data/htdocs/hmanics/help/helpmap.js","./opt/hp/hpsmh/data/htdocs/hmanics/help/ima00010.htm.ja","./opt/hp/hpsmh/data/htdocs/hmanics/help/ima00201.htm.ja","./opt/hp/hpsmh/data/htdocs/hmanics/help/ima00202.htm.ja","./opt/hp/hpsmh/data/htdocs/hmanics/help/ima00203.htm.ja","./opt/hp/hpsmh/data/htdocs/hmanics/help/ima00204.htm.ja","./opt/hp/hpsmh/data/htdocs/hmanics/help/ima00205.htm.ja","./opt/hp/hpsmh/data/htdocs/hmanics/help/welcome.htm.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/welcome.htm.ja","./opt/hp/hpsmh/data/htdocs/hmanics/help/whd_dpns.htm.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/whd_dpns.htm.ja","./opt/hp/hpsmh/data/htdocs/hmanics/help/whd_nvp10.htm.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/whd_tab0.gif","./opt/hp/hpsmh/data/htdocs/hmanics/help/whd_tab1.gif","./opt/hp/hpsmh/data/htdocs/hmanics/help/whd_tab2.gif","./opt/hp/hpsmh/data/htdocs/hmanics/help/whd_tab3.gif","./opt/hp/hpsmh/data/htdocs/hmanics/help/whd_tab4.gif","./opt/hp/hpsmh/data/htdocs/hmanics/help/whd_tab5.gif","./opt/hp/hpsmh/data/htdocs/hmanics/help/whd_tab6.gif","./opt/hp/hpsmh/data/htdocs/hmanics/help/whd_tabs.htm.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/whd_tabs.htm.ja","./opt/hp/hpsmh/data/htdocs/hmanics/help/whd_toc1.gif","./opt/hp/hpsmh/data/htdocs/hmanics/help/whd_toc2.gif","./opt/hp/hpsmh/data/htdocs/hmanics/help/whd_toc3.gif","./opt/hp/hpsmh/data/htdocs/hmanics/help/whd_toc4.gif","./opt/hp/hpsmh/data/htdocs/hmanics/help/whdata","./opt/hp/hpsmh/data/htdocs/hmanics/help/whdata/whftdata0.xml.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/whdata/whftdata0.xml.ja","./opt/hp/hpsmh/data/htdocs/hmanics/help/whdata/whfts.xml","./opt/hp/hpsmh/data/htdocs/hmanics/help/whdata/whfwdata0.xml.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/whdata/whfwdata1.xml.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/whdata/whfwdata2.xml.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/whdata/whidata0.xml.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/whdata/whidata0.xml.ja","./opt/hp/hpsmh/data/htdocs/hmanics/help/whdata/whidx.xml.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/whdata/whidx.xml.ja","./opt/hp/hpsmh/data/htdocs/hmanics/help/whdata/whtdata0.xml.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/whdata/whtdata0.xml.ja","./opt/hp/hpsmh/data/htdocs/hmanics/help/whdata/whtoc.xml.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/whdata/whtoc.xml.ja","./opt/hp/hpsmh/data/htdocs/hmanics/help/whfbody.htm.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/whfdhtml.htm.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/whfform.htm.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/whfform.htm.ja","./opt/hp/hpsmh/data/htdocs/hmanics/help/whfhost.js","./opt/hp/hpsmh/data/htdocs/hmanics/help/whform.js","./opt/hp/hpsmh/data/htdocs/hmanics/help/whhost.js","./opt/hp/hpsmh/data/htdocs/hmanics/help/whibody.htm.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/whidhtml.htm.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/whidhtml.htm.ja","./opt/hp/hpsmh/data/htdocs/hmanics/help/whiform.htm.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/whiform.htm.ja","./opt/hp/hpsmh/data/htdocs/hmanics/help/whihost.js","./opt/hp/hpsmh/data/htdocs/hmanics/help/whlang.js","./opt/hp/hpsmh/data/htdocs/hmanics/help/whmozemu.js","./opt/hp/hpsmh/data/htdocs/hmanics/help/whmsg.js","./opt/hp/hpsmh/data/htdocs/hmanics/help/whphost.js","./opt/hp/hpsmh/data/htdocs/hmanics/help/whproj.xml.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/whproj.xml.ja","./opt/hp/hpsmh/data/htdocs/hmanics/help/whproxy.js","./opt/hp/hpsmh/data/htdocs/hmanics/help/whstart.js","./opt/hp/hpsmh/data/htdocs/hmanics/help/whstub.js","./opt/hp/hpsmh/data/htdocs/hmanics/help/whtdhtml.htm.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/whthost.js","./opt/hp/hpsmh/data/htdocs/hmanics/help/whtopic.js","./opt/hp/hpsmh/data/htdocs/hmanics/help/whutils.js","./opt/hp/hpsmh/data/htdocs/hmanics/help/whver.js","./opt/hp/hpsmh/data/htdocs/hmanics/hmanics.js.php.en","./opt/hp/hpsmh/data/htdocs/hmanics/hmanics.js.php.ja","./opt/hp/hpsmh/data/htdocs/hmanics/hmanics.php.en","./opt/hp/hpsmh/data/htdocs/hmanics/hmanics.php.ja","./opt/hp/hpsmh/data/htdocs/hmanics/hmanics.snmp.php.en","./opt/hp/hpsmh/data/htdocs/hmanics/hmanics.snmp.php.ja","./opt/hp/hpsmh/data/htdocs/hmanics/hoenums.js.en","./opt/hp/hpsmh/data/htdocs/hmanics/hoenums.js.ja","./opt/hp/hpsmh/data/htdocs/hmanics/ifenums.js.en","./opt/hp/hpsmh/data/htdocs/hmanics/ifenums.js.ja","./opt/hp/hpsmh/data/htdocs/hmanics/images","./opt/hp/hpsmh/data/htdocs/hmanics/images/agntlogo.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/backgrnd.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/bttyhdr.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/cfghdr.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/cfgnav.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/crith.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/critical.jpg","./opt/hp/hpsmh/data/htdocs/hmanics/images/degraded.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/disabled.jpg","./opt/hp/hpsmh/data/htdocs/hmanics/images/disabth.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/dot-blck.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/dot-blue.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/dot-grn.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/dot-red.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/dot-wht.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/dot-yllw.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/exhdr.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/expbrd2.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/failed.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/helpptr.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/ima.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/line1.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/mass5.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/masshdr.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/mntrhdr.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/nic.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/nichdr.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/notslctd.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/ntos.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/ntoshdr.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/ok.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/perf.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/recov.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/recvrhdr.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/sbhdr.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/slctlft.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/slctrt.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/sysbrd2.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/unknown.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/utilhdr.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/utnav.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/warning.jpg","./opt/hp/hpsmh/data/htdocs/hmanics/images/warth.gif","./opt/hp/hpsmh/data/htdocs/hmanics/nc-cmmn.js.en","./opt/hp/hpsmh/data/htdocs/hmanics/nc-cmmn.js.ja","./opt/hp/hpsmh/data/htdocs/hmanics/nc-if.php.en","./opt/hp/hpsmh/data/htdocs/hmanics/nc-if.php.ja","./opt/hp/hpsmh/data/htdocs/hmanics/nc-log.php.en","./opt/hp/hpsmh/data/htdocs/hmanics/nc-log.php.ja","./opt/hp/hpsmh/data/htdocs/hmanics/nc-phy.php.en","./opt/hp/hpsmh/data/htdocs/hmanics/nc-phy.php.ja","./opt/hp/hpsmh/data/htdocs/hmanics/nc-sngl.php.en","./opt/hp/hpsmh/data/htdocs/hmanics/nc-sngl.php.ja","./opt/hp/hpsmh/data/htdocs/hmanics/nc-tmmnu.php.en","./opt/hp/hpsmh/data/htdocs/hmanics/nc-tmmnu.php.ja","./opt/hp/hpsmh/data/htdocs/hmanics/nicenums.js.en","./opt/hp/hpsmh/data/htdocs/hmanics/nicenums.js.ja","./opt/hp/hpsmh/data/htdocs/hmanics/nichead.js.en","./opt/hp/hpsmh/data/htdocs/hmanics/nichead.js.ja","./opt/hp/hpsmh/data/htdocs/hmanics/subframe.php.en","./opt/hp/hpsmh/data/htdocs/hmanics/subframe.php.ja","./opt/hp/hpsmh/data/htdocs/hmanics/vt.php.en","./opt/hp/hpsmh/data/htdocs/hmanics/vt.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv","./opt/hp/hpsmh/data/htdocs/hmaserv/cf-secur.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/cf-secur.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/cf-sinfo.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/cf-sinfo.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/common","./opt/hp/hpsmh/data/htdocs/hmaserv/common/compaq.js.en","./opt/hp/hpsmh/data/htdocs/hmaserv/common/compaq.js.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/common/cond.js.en","./opt/hp/hpsmh/data/htdocs/hmaserv/common/cond.js.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/common/dispbase.js.en","./opt/hp/hpsmh/data/htdocs/hmaserv/common/dispbase.js.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/common/helputil.js.en","./opt/hp/hpsmh/data/htdocs/hmaserv/common/helputil.js.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/common/navtable.js.en","./opt/hp/hpsmh/data/htdocs/hmaserv/common/navtable.js.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/common/numcnvrt.js.en","./opt/hp/hpsmh/data/htdocs/hmaserv/common/numcnvrt.js.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/common/oiddefs.inc","./opt/hp/hpsmh/data/htdocs/hmaserv/common/pagetags.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/common/pagetags.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/common/pagetags.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/common/pagetags.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/common/parsearg.js.en","./opt/hp/hpsmh/data/htdocs/hmaserv/common/parsearg.js.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/common/setitem.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/common/setitem.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/common/setmsgs.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/common/setmsgs.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/common/sets.js.en","./opt/hp/hpsmh/data/htdocs/hmaserv/common/sets.js.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/common/sorts.js.en","./opt/hp/hpsmh/data/htdocs/hmaserv/common/sorts.js.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/common/stditems.js.en","./opt/hp/hpsmh/data/htdocs/hmaserv/common/stditems.js.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/common/swtable.js.en","./opt/hp/hpsmh/data/htdocs/hmaserv/common/swtable.js.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/common/tables.js.en","./opt/hp/hpsmh/data/htdocs/hmaserv/common/tables.js.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/common/uidenums.js.en","./opt/hp/hpsmh/data/htdocs/hmaserv/common/uidenums.js.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/em-asset.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/em-asset.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/em-detl.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/em-detl.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/em-info-cclass.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/em-info-cclass.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/em-info.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/em-info.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/em-info1.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/em-info1.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/emenums.js.en","./opt/hp/hpsmh/data/htdocs/hmaserv/emenums.js.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/ex-commn.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/ex-commn.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/ex-info.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/ex-info.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/ex-res.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/ex-res.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/heenums.js.en","./opt/hp/hpsmh/data/htdocs/hmaserv/heenums.js.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help","./opt/hp/hpsmh/data/htdocs/hmaserv/help/about.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/about.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/bsscnbar.js.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/bsscnbar.js.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/default.css","./opt/hp/hpsmh/data/htdocs/hmaserv/help/defns.css","./opt/hp/hpsmh/data/htdocs/hmaserv/help/help.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/help.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/helpmap.js","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00011.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00011.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00012.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00012.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00013.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00013.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00014.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00014.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00015.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00015.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00016.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00016.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00017.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00017.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00018.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00018.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00019.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00019.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00020.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00020.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00021.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00021.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00022.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00022.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00023.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00023.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00024.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00024.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00046.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00046.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00080.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00080.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00081.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00081.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00082.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00082.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00083.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00083.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00084.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00084.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00085.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00085.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00116.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00116.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00117.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00117.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00150.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00150.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/navpane2.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/navpane2.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/nsdnsfix.jar.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/nsdnsfix.jar.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/pgsectn.gif.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/pgsectn.gif.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/servcont.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/servcont.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/servidx.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/servidx.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/toparrow.gif.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/toparrow.gif.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/webhelp.cab.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/webhelp.cab.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/webhelp.jar.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/webhelp.jar.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/webhelp.zip.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/webhelp.zip.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/welcome.gif.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/welcome.gif.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/whnonie4.css","./opt/hp/hpsmh/data/htdocs/hmaserv/hemenums.js.en","./opt/hp/hpsmh/data/htdocs/hmaserv/hemenums.js.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/hmaserv.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/hmaserv.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/images","./opt/hp/hpsmh/data/htdocs/hmaserv/images/agntlogo.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/backgrnd.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/bttyhdr.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/cfghdr.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/cfgnav.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/crith.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/critical.jpg","./opt/hp/hpsmh/data/htdocs/hmaserv/images/degraded.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/disabled.jpg","./opt/hp/hpsmh/data/htdocs/hmaserv/images/disabth.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/dot-blck.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/dot-blue.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/dot-grn.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/dot-red.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/dot-wht.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/dot-yllw.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/exhdr.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/expbrd2.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/failed.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/helpptr.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/ima.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/line1.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/major_15.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/major_20.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/mass5.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/masshdr.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/minor_15.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/minor_20.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/mntrhdr.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/nic.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/nichdr.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/normal_15.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/normal_20.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/notslctd.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/ntos.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/ntoshdr.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/ok.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/perf.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/recov.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/recvrhdr.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/sbhdr.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/slctlft.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/slctrt.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/sysbrd2.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/unknown.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/unknown_15.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/unknown_20.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/utilhdr.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/utnav.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/warning.jpg","./opt/hp/hpsmh/data/htdocs/hmaserv/images/warth.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/ms-flop.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/ms-flop.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-env.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-env.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-fan.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-fan.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-iml.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-iml.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-pconv.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-pconv.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-power.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-power.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-range.js.en","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-range.js.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-rawlg.js.en","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-rawlg.js.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-rblog.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-rblog.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-rbnic.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-rbnic.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-rboot.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-rboot.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-rcomm.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-rcomm.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-recov.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-recov.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-ribrd.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-ribrd.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/sb-cart.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/sb-cart.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/sb-cpu.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/sb-cpu.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/sb-info.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/sb-info.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/sb-mem.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/sb-mem.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/sb-resmem.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/sb-resmem.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/seenums.js.en","./opt/hp/hpsmh/data/htdocs/hmaserv/seenums.js.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/sienums.js.en","./opt/hp/hpsmh/data/htdocs/hmaserv/sienums.js.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/sm2enums.js.en","./opt/hp/hpsmh/data/htdocs/hmaserv/sm2enums.js.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/subframe.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/subframe.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/ut-info.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/ut-info.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor","./opt/hp/hpsmh/data/htdocs/hmastor/common","./opt/hp/hpsmh/data/htdocs/hmastor/common/compaq.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/common/compaq.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/common/cond.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/common/cond.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/common/dispbase.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/common/dispbase.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/common/helputil.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/common/helputil.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/common/navtable.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/common/navtable.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/common/numcnvrt.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/common/numcnvrt.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/common/oiddefs.inc","./opt/hp/hpsmh/data/htdocs/hmastor/common/pagetags.htm.en","./opt/hp/hpsmh/data/htdocs/hmastor/common/pagetags.htm.ja","./opt/hp/hpsmh/data/htdocs/hmastor/common/pagetags.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/common/pagetags.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/common/parsearg.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/common/parsearg.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/common/setitem.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/common/setitem.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/common/setmsgs.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/common/setmsgs.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/common/sets.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/common/sets.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/common/sorts.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/common/sorts.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/common/stditems.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/common/stditems.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/common/swtable.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/common/swtable.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/common/tables.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/common/tables.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/common/uidenums.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/common/uidenums.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/daenums.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/daenums.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/drive.gif","./opt/hp/hpsmh/data/htdocs/hmastor/drvblink.gif","./opt/hp/hpsmh/data/htdocs/hmastor/fcaenums.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/fcaenums.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/help","./opt/hp/hpsmh/data/htdocs/hmastor/help/about.htm.en","./opt/hp/hpsmh/data/htdocs/hmastor/help/about.htm.ja","./opt/hp/hpsmh/data/htdocs/hmastor/help/bsscnbar.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/help/bsscnbar.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/help/default.css","./opt/hp/hpsmh/data/htdocs/hmastor/help/defns.css","./opt/hp/hpsmh/data/htdocs/hmastor/help/help.htm.en","./opt/hp/hpsmh/data/htdocs/hmastor/help/help.htm.ja","./opt/hp/hpsmh/data/htdocs/hmastor/help/helpmap.js","./opt/hp/hpsmh/data/htdocs/hmastor/help/hotplug.gif","./opt/hp/hpsmh/data/htdocs/hmastor/help/ima00041.htm.en","./opt/hp/hpsmh/data/htdocs/hmastor/help/ima00041.htm.ja","./opt/hp/hpsmh/data/htdocs/hmastor/help/ima00042.htm.en","./opt/hp/hpsmh/data/htdocs/hmastor/help/ima00042.htm.ja","./opt/hp/hpsmh/data/htdocs/hmastor/help/ima00043.htm.en","./opt/hp/hpsmh/data/htdocs/hmastor/help/ima00043.htm.ja","./opt/hp/hpsmh/data/htdocs/hmastor/help/ima00044.htm.en","./opt/hp/hpsmh/data/htdocs/hmastor/help/ima00044.htm.ja","./opt/hp/hpsmh/data/htdocs/hmastor/help/ima00046.htm.en","./opt/hp/hpsmh/data/htdocs/hmastor/help/ima00046.htm.ja","./opt/hp/hpsmh/data/htdocs/hmastor/help/ima00047.htm.en","./opt/hp/hpsmh/data/htdocs/hmastor/help/ima00047.htm.ja","./opt/hp/hpsmh/data/htdocs/hmastor/help/ima00048.htm.en","./opt/hp/hpsmh/data/htdocs/hmastor/help/ima00048.htm.ja","./opt/hp/hpsmh/data/htdocs/hmastor/help/ima00049.htm.en","./opt/hp/hpsmh/data/htdocs/hmastor/help/ima00049.htm.ja","./opt/hp/hpsmh/data/htdocs/hmastor/help/major_32.gif","./opt/hp/hpsmh/data/htdocs/hmastor/help/navpane2.htm.en","./opt/hp/hpsmh/data/htdocs/hmastor/help/navpane2.htm.ja","./opt/hp/hpsmh/data/htdocs/hmastor/help/normal_15.gif","./opt/hp/hpsmh/data/htdocs/hmastor/help/nsdnsfix.jar.en","./opt/hp/hpsmh/data/htdocs/hmastor/help/nsdnsfix.jar.ja","./opt/hp/hpsmh/data/htdocs/hmastor/help/pgsectn.gif.en","./opt/hp/hpsmh/data/htdocs/hmastor/help/pgsectn.gif.ja","./opt/hp/hpsmh/data/htdocs/hmastor/help/storcont.htm.en","./opt/hp/hpsmh/data/htdocs/hmastor/help/storcont.htm.ja","./opt/hp/hpsmh/data/htdocs/hmastor/help/storidx.htm.en","./opt/hp/hpsmh/data/htdocs/hmastor/help/storidx.htm.ja","./opt/hp/hpsmh/data/htdocs/hmastor/help/storsrch.htm.en","./opt/hp/hpsmh/data/htdocs/hmastor/help/storsrch.htm.ja","./opt/hp/hpsmh/data/htdocs/hmastor/help/toparrow.gif","./opt/hp/hpsmh/data/htdocs/hmastor/help/webhelp.cab.en","./opt/hp/hpsmh/data/htdocs/hmastor/help/webhelp.cab.ja","./opt/hp/hpsmh/data/htdocs/hmastor/help/webhelp.jar.en","./opt/hp/hpsmh/data/htdocs/hmastor/help/webhelp.jar.ja","./opt/hp/hpsmh/data/htdocs/hmastor/help/webhelp.zip.en","./opt/hp/hpsmh/data/htdocs/hmastor/help/webhelp.zip.ja","./opt/hp/hpsmh/data/htdocs/hmastor/help/welcome.gif.en","./opt/hp/hpsmh/data/htdocs/hmastor/help/welcome.gif.ja","./opt/hp/hpsmh/data/htdocs/hmastor/hmastor.js.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/hmastor.js.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/hmastor.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/hmastor.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/hmastor.snmp.php","./opt/hp/hpsmh/data/htdocs/hmastor/hotplug.jpg","./opt/hp/hpsmh/data/htdocs/hmastor/idenums.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/idenums.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/images","./opt/hp/hpsmh/data/htdocs/hmastor/images/agntlogo.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/backgrnd.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/bttyhdr.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/cfghdr.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/cfgnav.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/crith.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/critical.jpg","./opt/hp/hpsmh/data/htdocs/hmastor/images/degraded.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/disabled.jpg","./opt/hp/hpsmh/data/htdocs/hmastor/images/disabth.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/dot-blck.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/dot-blue.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/dot-grn.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/dot-red.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/dot-wht.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/dot-yllw.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/exhdr.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/expbrd2.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/failed.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/helpptr.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/ima.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/line1.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/major_15.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/major_20.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/mass5.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/masshdr.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/minor_15.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/minor_20.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/mntrhdr.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/nic.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/nichdr.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/normal_15.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/normal_20.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/notslctd.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/ntos.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/ntoshdr.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/ok.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/perf.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/recov.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/recvrhdr.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/sbhdr.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/slctlft.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/slctrt.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/sysbrd2.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/unknown.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/unknown_15.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/unknown_20.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/utilhdr.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/utnav.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/warning.jpg","./opt/hp/hpsmh/data/htdocs/hmastor/images/warth.gif","./opt/hp/hpsmh/data/htdocs/hmastor/isenums.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/isenums.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-dabox.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-dabox.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-dacmn.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-dacmn.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-dactl.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-dactl.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-dalog.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-dalog.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-damnu.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-damnu.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-daphy.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-daphy.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-drvbx.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-drvbx.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-dtape.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-dtape.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-dtlib.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-dtlib.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-fccmn.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-fccmn.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-fccnt.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-fccnt.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-fccon.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-fccon.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-fcctl.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-fcctl.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-fces.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-fces.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-fclog.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-fclog.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-fcmnu.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-fcmnu.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-fcphy.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-fcphy.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-fcss.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-fcss.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-fcsw.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-fcsw.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-ftape.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-ftape.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-ftctl.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-ftctl.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-ftlib.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-ftlib.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-ftmnu.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-ftmnu.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-idcmn.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-idcmn.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-idctl.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-idctl.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-idlog.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-idlog.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-idmnu.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-idmnu.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-idphy.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-idphy.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-iscmn.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-iscmn.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-iscxn.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-iscxn.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-isinit.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-isinit.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-isins.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-isins.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-ismnu.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-ismnu.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-isnod.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-isnod.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-isssn.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-isssn.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-raids.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-raids.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-sabox.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-sabox.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-sahba.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-sahba.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-salog.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-salog.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-samnu.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-samnu.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-saphy.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-saphy.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-sas.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-sas.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-sasc.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-sasc.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-satap.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-satap.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-sclog.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-sclog.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-scmnu.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-scmnu.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-scsi.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-scsi.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-scsic.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-scsic.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-sctl.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-sctl.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/sacenums.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/sacenums.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/scsenums.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/scsenums.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ssenums.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/ssenums.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/subframe.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/subframe.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/tpenums.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/tpenums.js.ja","./opt/hp/hpsmh/data/htdocs/webagent","./opt/hp/hpsmh/data/htdocs/webagent/agent.php.en","./opt/hp/hpsmh/data/htdocs/webagent/agent.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/cf-clstr.php.en","./opt/hp/hpsmh/data/htdocs/webagent/cf-clstr.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/cf-swver.php.en","./opt/hp/hpsmh/data/htdocs/webagent/cf-swver.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/clsenums.js.en","./opt/hp/hpsmh/data/htdocs/webagent/clsenums.js.ja","./opt/hp/hpsmh/data/htdocs/webagent/common","./opt/hp/hpsmh/data/htdocs/webagent/common/compaq.js.en","./opt/hp/hpsmh/data/htdocs/webagent/common/compaq.js.ja","./opt/hp/hpsmh/data/htdocs/webagent/common/cond.js.en","./opt/hp/hpsmh/data/htdocs/webagent/common/cond.js.ja","./opt/hp/hpsmh/data/htdocs/webagent/common/dispbase.js.en","./opt/hp/hpsmh/data/htdocs/webagent/common/dispbase.js.ja","./opt/hp/hpsmh/data/htdocs/webagent/common/helputil.js.en","./opt/hp/hpsmh/data/htdocs/webagent/common/helputil.js.ja","./opt/hp/hpsmh/data/htdocs/webagent/common/navtable.js.en","./opt/hp/hpsmh/data/htdocs/webagent/common/navtable.js.ja","./opt/hp/hpsmh/data/htdocs/webagent/common/numcnvrt.js.en","./opt/hp/hpsmh/data/htdocs/webagent/common/numcnvrt.js.ja","./opt/hp/hpsmh/data/htdocs/webagent/common/oiddefs.inc","./opt/hp/hpsmh/data/htdocs/webagent/common/pagetags.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/common/pagetags.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/common/pagetags.php.en","./opt/hp/hpsmh/data/htdocs/webagent/common/pagetags.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/common/parsearg.js.en","./opt/hp/hpsmh/data/htdocs/webagent/common/parsearg.js.ja","./opt/hp/hpsmh/data/htdocs/webagent/common/setitem.php.en","./opt/hp/hpsmh/data/htdocs/webagent/common/setitem.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/common/setmsgs.php.en","./opt/hp/hpsmh/data/htdocs/webagent/common/setmsgs.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/common/sets.js.en","./opt/hp/hpsmh/data/htdocs/webagent/common/sets.js.ja","./opt/hp/hpsmh/data/htdocs/webagent/common/sorts.js.en","./opt/hp/hpsmh/data/htdocs/webagent/common/sorts.js.ja","./opt/hp/hpsmh/data/htdocs/webagent/common/stditems.js.en","./opt/hp/hpsmh/data/htdocs/webagent/common/stditems.js.ja","./opt/hp/hpsmh/data/htdocs/webagent/common/swtable.js.en","./opt/hp/hpsmh/data/htdocs/webagent/common/swtable.js.ja","./opt/hp/hpsmh/data/htdocs/webagent/common/tables.js.en","./opt/hp/hpsmh/data/htdocs/webagent/common/tables.js.ja","./opt/hp/hpsmh/data/htdocs/webagent/common/uidenums.js.en","./opt/hp/hpsmh/data/htdocs/webagent/common/uidenums.js.ja","./opt/hp/hpsmh/data/htdocs/webagent/cpqmibmap.txt","./opt/hp/hpsmh/data/htdocs/webagent/cpqthrsh.jar","./opt/hp/hpsmh/data/htdocs/webagent/cpuinfo.php.en","./opt/hp/hpsmh/data/htdocs/webagent/cpuinfo.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/gcchcthr.php.en","./opt/hp/hpsmh/data/htdocs/webagent/gcchcthr.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/gccputhr.php.en","./opt/hp/hpsmh/data/htdocs/webagent/gccputhr.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/gcmemthr.php.en","./opt/hp/hpsmh/data/htdocs/webagent/gcmemthr.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/groupcfg.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/groupcfg.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/grpcfg.php","./opt/hp/hpsmh/data/htdocs/webagent/help","./opt/hp/hpsmh/data/htdocs/webagent/help/SNMPop.gif.en","./opt/hp/hpsmh/data/htdocs/webagent/help/about.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/about.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/bsscnbar.js.en","./opt/hp/hpsmh/data/htdocs/webagent/help/bsscnbar.js.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/cachconf.gif","./opt/hp/hpsmh/data/htdocs/webagent/help/cachconf.gif.en","./opt/hp/hpsmh/data/htdocs/webagent/help/cachconf.gif.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/cpuconf.gif","./opt/hp/hpsmh/data/htdocs/webagent/help/cpuconf.gif.en","./opt/hp/hpsmh/data/htdocs/webagent/help/cpuconf.gif.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/default.css","./opt/hp/hpsmh/data/htdocs/webagent/help/defns.css","./opt/hp/hpsmh/data/htdocs/webagent/help/help.htm","./opt/hp/hpsmh/data/htdocs/webagent/help/help.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/help.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/helpmap.js","./opt/hp/hpsmh/data/htdocs/webagent/help/hostcont.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/hostcont.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/hostidx.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/hostidx.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00000.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00000.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00007.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00007.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00008.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00008.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00009.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00009.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00013.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00013.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00025.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00025.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00030.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00030.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00040.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00040.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00047.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00047.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00054.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00054.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00055.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00055.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00056.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00056.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00057.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00057.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00058.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00058.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00059.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00059.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00090.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00090.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00091.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00091.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00099.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00099.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00100.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00100.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00101.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00101.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00102.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00102.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00103.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00103.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00104.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00104.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00105.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00105.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00106.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00106.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00107.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00107.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00108.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00108.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00109.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00109.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00110.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00110.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00111.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00111.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00112.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00112.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00113.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00113.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00114.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00114.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00115.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00115.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00116.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00116.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00117.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00117.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00118.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00118.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00119.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00119.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00120.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00120.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/navpane2.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/navpane2.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/nsdnsfix.jar.en","./opt/hp/hpsmh/data/htdocs/webagent/help/nsdnsfix.jar.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/pagefile.gif","./opt/hp/hpsmh/data/htdocs/webagent/help/pagefile.gif.en","./opt/hp/hpsmh/data/htdocs/webagent/help/pagefile.gif.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/pgsectn.gif.en","./opt/hp/hpsmh/data/htdocs/webagent/help/pgsectn.gif.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/snmpop.gif.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/snmppage.gif","./opt/hp/hpsmh/data/htdocs/webagent/help/snmppage.gif.en","./opt/hp/hpsmh/data/htdocs/webagent/help/snmppage.gif.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/toparrow.gif","./opt/hp/hpsmh/data/htdocs/webagent/help/toparrow.gif.en","./opt/hp/hpsmh/data/htdocs/webagent/help/toparrow.gif.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/webhelp.cab.en","./opt/hp/hpsmh/data/htdocs/webagent/help/webhelp.cab.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/webhelp.jar.en","./opt/hp/hpsmh/data/htdocs/webagent/help/webhelp.jar.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/webhelp.zip.en","./opt/hp/hpsmh/data/htdocs/webagent/help/webhelp.zip.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/welcome.gif.en","./opt/hp/hpsmh/data/htdocs/webagent/help/welcome.gif.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/whnonie4.css","./opt/hp/hpsmh/data/htdocs/webagent/images","./opt/hp/hpsmh/data/htdocs/webagent/images/agntlogo.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/backgrnd.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/bttyhdr.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/cfghdr.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/cfgnav.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/crith.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/critical.jpg","./opt/hp/hpsmh/data/htdocs/webagent/images/degraded.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/disabled.jpg","./opt/hp/hpsmh/data/htdocs/webagent/images/disabth.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/dot-blck.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/dot-blue.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/dot-grn.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/dot-red.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/dot-wht.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/dot-yllw.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/exhdr.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/expbrd2.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/failed.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/helpptr.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/ima.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/line1.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/major_15.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/major_20.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/mass5.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/masshdr.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/minor_15.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/minor_20.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/mntrhdr.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/nic.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/nichdr.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/normal_15.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/normal_20.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/notslctd.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/ntos.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/ntoshdr.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/ok.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/perf.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/recov.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/recvrhdr.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/sbhdr.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/slctlft.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/slctrt.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/sysbrd2.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/unknown.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/unknown_15.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/unknown_20.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/utilhdr.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/utnav.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/warning.jpg","./opt/hp/hpsmh/data/htdocs/webagent/images/warth.gif","./opt/hp/hpsmh/data/htdocs/webagent/index.tpl.en","./opt/hp/hpsmh/data/htdocs/webagent/index.tpl.ja","./opt/hp/hpsmh/data/htdocs/webagent/ldskinfo.php.en","./opt/hp/hpsmh/data/htdocs/webagent/ldskinfo.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/lxsnmpconf.php.en","./opt/hp/hpsmh/data/htdocs/webagent/lxsnmpconf.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/meminfo.php.en","./opt/hp/hpsmh/data/htdocs/webagent/meminfo.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/menu.php.en","./opt/hp/hpsmh/data/htdocs/webagent/menu.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/ms-space.php.en","./opt/hp/hpsmh/data/htdocs/webagent/ms-space.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/netinfo.php.en","./opt/hp/hpsmh/data/htdocs/webagent/netinfo.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/netmenu.php.en","./opt/hp/hpsmh/data/htdocs/webagent/netmenu.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/os-enums.js.en","./opt/hp/hpsmh/data/htdocs/webagent/os-enums.js.ja","./opt/hp/hpsmh/data/htdocs/webagent/pdskinfo.php.en","./opt/hp/hpsmh/data/htdocs/webagent/pdskinfo.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/procinfo.php.en","./opt/hp/hpsmh/data/htdocs/webagent/procinfo.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/security.php.en","./opt/hp/hpsmh/data/htdocs/webagent/security.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/securset.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/securset.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/servinfo.php.en","./opt/hp/hpsmh/data/htdocs/webagent/servinfo.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/setthreshold.php.en","./opt/hp/hpsmh/data/htdocs/webagent/setthreshold.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/setup.php.en","./opt/hp/hpsmh/data/htdocs/webagent/setup.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/snmpagnt.php.en","./opt/hp/hpsmh/data/htdocs/webagent/snmpagnt.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/snmpcfg.xsl","./opt/hp/hpsmh/data/htdocs/webagent/subframe.php.en","./opt/hp/hpsmh/data/htdocs/webagent/subframe.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/tcpinfo.php.en","./opt/hp/hpsmh/data/htdocs/webagent/tcpinfo.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/tpltophp.pl","./opt/hp/hpsmh/data/htdocs/webagent/trap.php.en","./opt/hp/hpsmh/data/htdocs/webagent/trap.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/trapset.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/trapset.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/tsk-uid.php.en","./opt/hp/hpsmh/data/htdocs/webagent/tsk-uid.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/webagent.php.en","./opt/hp/hpsmh/data/htdocs/webagent/webagent.php.ja","./opt/hp/hpsmh/data/smhutil","./opt/hp/hpsmh/data/smhutil/ginkgochp.inc","./opt/hp/hpsmh/data/smhutil/ginkgoprop.inc","./opt/hp/hpsmh/data/smhutil/ginkgoset.inc","./opt/hp/hpsmh/data/smhutil/ginkgosnmp.inc","./opt/hp/hpsmh/data/smhutil/testdata.txt","./opt/hp/hpsmh/data/webapp-data/hmanics.chpinput.txt","./opt/hp/hpsmh/data/webapp-data/hmaserv","./opt/hp/hpsmh/data/webapp-data/hmaserv/hmaserv.ini","./opt/hp/hpsmh/data/webapp-data/hmastor","./opt/hp/hpsmh/data/webapp-data/hmastor.chpinput.txt","./opt/hp/hpsmh/data/webapp-data/hmastor/hmastor.ini","./opt/hp/hpsmh/data/webapp-data/webagent","./opt/hp/hpsmh/data/webapp-data/webagent/inc","./opt/hp/hpsmh/data/webapp-data/webagent/inc/cimomfuncs.inc","./opt/hp/hpsmh/data/webapp-data/webagent/inc/define.inc","./opt/hp/hpsmh/data/webapp-data/webagent/inc/footer.inc","./opt/hp/hpsmh/data/webapp-data/webagent/inc/getcfg.inc","./opt/hp/hpsmh/data/webapp-data/webagent/inc/grpcfg.inc","./opt/hp/hpsmh/data/webapp-data/webagent/inc/header.inc","./opt/hp/hpsmh/data/webapp-data/webagent/inc/properties.inc","./opt/hp/hpsmh/data/webapp-data/webagent/webagent.ini","./opt/hp/hpsmh/webapp/hmanics.xml","./opt/hp/hpsmh/webapp/hmaserv.xml","./opt/hp/hpsmh/webapp/hmastor.xml","./opt/hp/hpsmh/webapp/webagent.xml","./usr/share/man/man4/hp-smh-templates.4.gz"],"md5sum":"85b767973f9e6aabd2eb697b26d924df","name":"hp-smh-templates-10.8.1-1487.3.noarch.rpm","release":"2019-02-21T08:40:01","revision":"0","sha1sum":"7088c484f1308844e5cee6a1ce071c6e5244372c","size":"3MB","target_guids":[],"type_of_change":"0","version":"10.8.1"}],"id":{"product":"7481c4f359924b82adf02da5a315552d","version":"915814ba3e3c4667b44af6191061b825"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[],"reboot_required":""},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<P>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</P>\n<P>To install the package type: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;rpm -ivh hp-smh-templates-&lt;version&gt;.rpm</P>\n<P>To check whether the package is installed type: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;rpm –q hp-smh-templates</P>\n<P>Additional help is available by typing: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;man hp-smh-templates</P>"},{"lang":"ja","x_late":"<P>システム管理者（root）としてログインし、RPMをご使用のハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</P>\n<P>パッケージをインストールするには、次のようにタイプします。 </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;rpm -ivh hp-smh-templates-&lt;version&gt;.rpm</P>\n<P>パッケージがインストールされているかどうか確認するには、次のようにタイプします。 </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;rpm -q hp-smh-templates</P>\n<P>以下のコマンドを実行してヘルプを参照してください。 </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;man hp-smh-templates</P>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Linux 的 HPE System Management Homepage (系統管理首頁) 範本"},{"lang":"en","x_late":"HPE System Management Homepage Templates for Linux"},{"lang":"ko","x_late":"Linux용 HPE 시스템 관리 홈 페이지 템플릿"},{"lang":"ja","x_late":"HPE System Management Homepageテンプレート for Linux"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"3309","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3307","subdev":"3309","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (x86)","platform":"suse_linux_enterprise_server_x86","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86)","platform":"red_hat_enterprise_linux_x86","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-02-15T16:33:01","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial support for&nbsp;SUSE LINUX Enterprise Server 15.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"J02","value":"HP ProLiant ML350e Gen8 v2 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"P63","value":"HP ProLiant DL370 G6 Server"},{"key":"D22","value":"HP ProLiant ML350 G6 Server"},{"key":"I24","value":"HP ProLiant BL460c G6 Server"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I24","value":"HP ProLiant WS460c G6 Workstation Blade"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"P78","value":"HP ProLiant ML310e Gen8 v2 Server"},{"key":"I25","value":"HP ProLiant BL620c G7 Server"},{"key":"P69","value":"HP ProLiant SL390s G7 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A15","value":"HP ProLiant DL785 G6 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"P65","value":"HP ProLiant DL580 G7 Server"},{"key":"A17","value":"HP ProLiant BL685c G6 Server"},{"key":"W07","value":"HP ProLiant DL320 G6 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"I26","value":"HP ProLiant BL2x220c G6 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"A31","value":"HP ProLiant SL4545 G7 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"P83","value":"HP ProLiant SL210t Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P68","value":"HP ProLiant DL360 G7 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"I25","value":"HP ProLiant BL680c G7 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"J01","value":"HP ProLiant DL120 G7 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P88","value":"HP ProLiant ML10 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"A20","value":"HP ProLiant BL685c G7 Server"},{"key":"P67","value":"HP ProLiant DL380 G7 Server"},{"key":"O20","value":"HP ProLiant DL180 G6 Server"},{"key":"I22","value":"HP ProLiant BL280c G6 Server"},{"key":"P66","value":"HP ProLiant DL980 G7 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"O41","value":"HP ProLiant MicroServer"},{"key":"A19","value":"HP ProLiant BL465c G7 Server"},{"key":"A18","value":"HP ProLiant DL385 G7 Server"},{"key":"I21","value":"HP ProLiant BL490c G6 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"J01","value":"HP ProLiant ML110 G7 Server"},{"key":"A22","value":"HP ProLiant DL385 G6 Server"},{"key":"O21","value":"HP ProLiant ML150 G6 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"O33","value":"HP ProLiant DL160 G6 Server"},{"key":"I14","value":"HP ProLiant BL480c Server"},{"key":"I15","value":"HP ProLiant BL460c Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"J06","value":"HP ProLiant MicroServer Gen8"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"A16","value":"HP ProLiant DL585 G7 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"O37","value":"HP ProLiant DL165 G7 Server"},{"key":"O37","value":"HP ProLiant SL165z G7 Server"},{"key":"I27","value":"HP ProLiant BL460c G7 Server"},{"key":"I28","value":"HP ProLiant BL490c G7 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"P64","value":"HP ProLiant DL360 G6 Server"},{"key":"P62","value":"HP ProLiant DL380 G6 Server"},{"key":"P63","value":"HP ProLiant ML370 G6 Server"},{"key":"A24","value":"HP ProLiant SL335s G7 Server"},{"key":"O34","value":"HP ProLiant DL170h G6 Server"},{"key":"A14","value":"HP ProLiant BL495c G6 Server"},{"key":"O40","value":"HP ProLiant SL170s G6 Server"},{"key":"A13","value":"HP ProLiant BL465c G6 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"W07","value":"HP ProLiant ML330 G6 Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"},{"key":"I29","value":"HP ProLiant BL2x220c G7 Server"}],"sw_keys":[{"name":"hp-smh-templates","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":""}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GVYYU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMPN6TG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304756595955","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SATA drive models: MB6000GVYYU"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。MB6000GVYYU"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB6000GVYYU Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5280008","datemodified":"2021-07-23T07:31:40","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-bdc37cb37f-HPG2-9.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdc37cb37f-HPG2-9.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdc37cb37f-HPG2-9.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdc37cb37f-HPG2-9.1/CP048169.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdc37cb37f-HPG2-9.1/SMPN6TG2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdc37cb37f-HPG2-9.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdc37cb37f-HPG2-9.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdc37cb37f-HPG2-9.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdc37cb37f-HPG2-9.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048169.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048169.scexe"],"md5sum":"d9254815a37ff8aa72a6cf1a41b6a094","name":"firmware-hdd-bdc37cb37f-HPG2-9.1.x86_64.rpm","release":"2021-07-23T07:19:15","revision":"0","sha1sum":"6ad381fbd87734eb38d9c457ca1b5eb9cbcec1ef","size":"5MB","target_guids":["002340a5-4d00-3642-3030-304756595955"],"type_of_change":"1","version":"HPG2"}],"id":{"product":"ff74c7c5dcd8491d9c1177c5c1de73f4","version":"3ebfa78763694b1f93535e4e524b3efe"},"installation":{"command":"CP040310.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB6000GVYYU Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB6000GVYYUドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB6000GVYYU","target_guid":"002340a5-4d00-3642-3030-304756595955","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T19:47:39","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000GVYYU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"The HPE Storage Fibre Channel (FC) adapter kit contains version 12.8.334.6 of the Emulex Storport driver for Extended Systems which provides Mezzanine Fibre Channel-Host Bus Adapter (HBA) driver support for HPE Storage RAID Arrays."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"2285344","datemodified":"2021-08-26T10:02:02","file_list":["cp049106.xml","cpqsetup.exe","elxdrvr-fc-12.8.334.6-4.exe","ElxStorInstaller.dll","install.xml","SysConfig.frm","SysConfig.frm.ja"],"md5sum":"5fa4f53524de52f0ce3881bb77abcb94","name":"cp049106.exe","release":"2021-08-26T09:58:07","revision":"0","sha1sum":"df9b7063abb89113dca74cc397b41dcacb9b0055","size":"2MB","target_guids":[],"type_of_change":"1","version":"12.8.334.6"}],"id":{"product":"ed27e5720be14388a183c9d0b8509baa","version":"0012688c721d4ce181497e32b0c20c37"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation.</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Mezzanine Fibre Channel Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2012R2"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-23T06:21:13","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to driver version&nbsp;12.8.334.6</p>\n\n<p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p>\n\n<p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p>\n\n<p>The extracted files are located:</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p>\n\n<p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2019</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"elxfc.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000150GWCNN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3135-304757434e4e","Version":"HPG1"},{"DeviceName":"VK000240GWCNP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757434e50","Version":"HPG1"},{"DeviceName":"VK000480GWCNQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757434e51","Version":"HPG1"},{"DeviceName":"VK000960GWCNR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757434e52","Version":"HPG1"},{"DeviceName":"VK001600GWCNT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3630-304757434e54","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000150GWCNN, VK000240GWCNP, VK000480GWCNQ, VK000960GWCNR and VK001600GWCNT Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000150GWCNN、VK000240GWCNP、VK000480GWCNQ、VK000960GWCNR および VK001600GWCNT ドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VK000150GWCNN, VK000240GWCNP, VK000480GWCNQ, VK000960GWCNR&nbsp;and VK001600GWCNT&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p>\n\n<ul>\n\t<li>&nbsp;&nbsp;Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4690895","datemodified":"2021-07-23T10:41:58","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-6e3845def5-HPG1-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-6e3845def5-HPG1-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-6e3845def5-HPG1-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6e3845def5-HPG1-6.1/4IDVHPG1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-6e3845def5-HPG1-6.1/CP048185.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-6e3845def5-HPG1-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6e3845def5-HPG1-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-6e3845def5-HPG1-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-6e3845def5-HPG1-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048185.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048185.scexe"],"md5sum":"aaee53f8fc1dbe0bb63f4073bcd08d25","name":"firmware-hdd-6e3845def5-HPG1-6.1.x86_64.rpm","release":"2021-07-23T10:28:04","revision":"0","sha1sum":"68c286c5ca0d583a56b3baed9191fbde38f8ab31","size":"4MB","target_guids":["562340a5-304b-3030-3135-304757434e4e","562340a5-304b-3030-3234-304757434e50","562340a5-304b-3030-3438-304757434e51","562340a5-304b-3030-3936-304757434e52","562340a5-304b-3130-3630-304757434e54"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"bc34fe37ff6f4e0b9f7866222b805e05","version":"6c6e53607a1046918b40cfc9de16b04c"},"installation":{"command":"CP040345.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK000150GWCNN, VK000240GWCNP, VK000480GWCNQ, VK000960GWCNR and VK001600GWCNT Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VK000150GWCNN、VK000240GWCNP、VK000480GWCNQ、VK000960GWCNR、およびVK001600GWCNTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VK001600GWCNT","target_guid":"562340a5-304b-3130-3630-304757434e54","type":"sata"},{"id":"VK000960GWCNR","target_guid":"562340a5-304b-3030-3936-304757434e52","type":"sata"},{"id":"VK000480GWCNQ","target_guid":"562340a5-304b-3030-3438-304757434e51","type":"sata"},{"id":"VK000240GWCNP","target_guid":"562340a5-304b-3030-3234-304757434e50","type":"sata"},{"id":"VK000150GWCNN","target_guid":"562340a5-304b-3030-3135-304757434e4e","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T20:54:10","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK000480GWCNQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000150GWCNN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001600GWCNT","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWCNR","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWCNP","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWZJF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304a575a4a46","Version":"HPD4"},{"DeviceName":"VO001920JWZJH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304a575a4a48","Version":"HPD4"},{"DeviceName":"VO003840JWZJK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304a575a4a4b","Version":"HPD4"},{"DeviceName":"VO007680JWZJL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304a575a4a4c","Version":"HPD4"},{"DeviceName":"VO015360JWZJN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3336-304a575a4a4e","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO000960JWZJF、VO001920JWZJH、VO003840JWZJK、VO007680JWZJL、およびVO015360JWZJNドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5043152","datemodified":"2021-07-23T10:25:58","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD4-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD4-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD4-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD4-2.1/CP048218.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD4-2.1/GPM1643ASAD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD4-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD4-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD4-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD4-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048218.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048218.scexe"],"md5sum":"6f93631cf50fdbee01683d42c8e40d0f","name":"firmware-hdd-35fd24601f-HPD4-2.1.x86_64.rpm","release":"2021-07-23T10:13:06","revision":"0","sha1sum":"67f46642bdc2e92d8e1d4e8b674e12f269a70efb","size":"4MB","target_guids":["562340a5-304f-3030-3936-304a575a4a46","562340a5-304f-3130-3932-304a575a4a48","562340a5-304f-3330-3834-304a575a4a4b","562340a5-304f-3730-3638-304a575a4a4c","562340a5-304f-3531-3336-304a575a4a4e"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"c4ef0470aa934a20948f1a88d8eff26d","version":"cb25d006095f435c87e27644a1b17df7"},"installation":{"command":"CP043252.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート:</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするには、以下のコマンドの<strong>1つ</strong>を実行します:\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するには Service Pack for ProLiant から以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux（x64）- VO000960JWZJF、VO001920JWZJH、VO003840JWZJK、VO007680JWZJLおよびVO015360JWZJNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VO015360JWZJN","target_guid":"562340a5-304f-3531-3336-304a575a4a4e","type":"sas"},{"id":"VO007680JWZJL","target_guid":"562340a5-304f-3730-3638-304a575a4a4c","type":"sas"},{"id":"VO003840JWZJK","target_guid":"562340a5-304f-3330-3834-304a575a4a4b","type":"sas"},{"id":"VO001920JWZJH","target_guid":"562340a5-304f-3130-3932-304a575a4a48","type":"sas"},{"id":"VO000960JWZJF","target_guid":"562340a5-304f-3030-3936-304a575a4a46","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T12:43:46","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Modify Drive Vendor Identification String (VID) in Inquiry page from &ldquo;HP&rdquo; to &ldquo;HPE&rdquo;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO015360JWZJN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO007680JWZJL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920JWZJH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000960JWZJF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003840JWZJK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWCFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757434644","Version":"HPG3"},{"DeviceName":"VK000480GWCFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757434645","Version":"HPG3"},{"DeviceName":"VK000960GWCFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757434646","Version":"HPG3"},{"DeviceName":"VK001920GWCFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757434648","Version":"HPG3"},{"DeviceName":"VK003840GWCFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-30475743464b","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000240GWCFD ,VK000480GWCFE ,VK000960GWCFF ,VK001920GWCFH and VK003840GWCFK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK000240GWCFD, VK000480GWCFE, VK000960GWCFF, VK001920GWCFH and VK003840GWCFK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None&nbsp;&nbsp;</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"15790762","datemodified":"2021-08-27T09:32:35","file_list":["/CP048407_BUILD_2.data","/CP048407.vmexe","/CP048407.vmexe64","/CP048407.vmfile","/CP048407_VMw.zip","/CP048407.xml","/payload.json","/CP048407_VMw.zip/index.xml","/CP048407_VMw.zip/vendor-index.xml","/CP048407_VMw.zip/metadata.zip","/CP048407_VMw.zip/vib20/CP048407/HPE_bootbank_CP048407_HPG3.2-7.0.0.15843807.vib","/CP048407_VMw.zip/metadata.zip/vendor-index.xml","/CP048407_VMw.zip/metadata.zip/vmware.xml","/CP048407_VMw.zip/metadata.zip/vibs/CP048407--2459765311620867619.xml","/CP048407_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048407_HPG3.2-7.0.0.15843807.xml"],"md5sum":"e0add333e57e1286b0817ca2177c2319","name":"CP048407.zip","release":"2021-08-27T09:27:13","revision":"0","sha1sum":"8b8aeeaf7f1a1f926bb42aa617d8ce34cfd9a3d2","size":"15MB","target_guids":["562340a5-304b-3030-3234-304757434644","562340a5-304b-3030-3438-304757434645","562340a5-304b-3030-3936-304757434646","562340a5-304b-3130-3932-304757434648","562340a5-304b-3330-3834-30475743464b"],"type_of_change":"1","version":"HPG3","vib_list":[{"name":"CP048407","version":"HPG3.2-7.0.0.15843807"}]}],"id":{"product":"0d1bdabb9bd2412a9e8131f41d12a1c0","version":"fde97230729f4a86a8b8584aa5a07e64"},"installation":{"command":"CP040671.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK000240GWCFD, VK000480GWCFE, VK000960GWCFF, VK001920GWCFH and VK003840GWCFK   Drives."},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VK000240GWCFD、VK000480GWCFE、VK000960GWCFF、VK001920GWCFH およびVK003840GWCFK ドライブ。"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VK003840GWCFK","target_guid":"562340a5-304b-3330-3834-30475743464b","type":"sata"},{"id":"VK001920GWCFH","target_guid":"562340a5-304b-3130-3932-304757434648","type":"sata"},{"id":"VK000960GWCFF","target_guid":"562340a5-304b-3030-3936-304757434646","type":"sata"},{"id":"VK000480GWCFE","target_guid":"562340a5-304b-3030-3438-304757434645","type":"sata"},{"id":"VK000240GWCFD","target_guid":"562340a5-304b-3030-3234-304757434644","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T04:18:55","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK001920GWCFH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWCFF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWCFD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWCFE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GWCFK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"此元件套件包含的驅動程式適用於在 Windows Server 2016 執行的 HPE Intel E1R Gigabit Ethernet NIC。"},{"lang":"en","x_late":"This Component Package contains the driver for HPE Intel E1R Gigabit Ethernet NICs running under Microsoft Windows Server 2016."},{"lang":"ko","x_late":"이 구성 요소 패키지에는 Microsoft Windows Server 2016에서 실행되는 HPE Intel E1R 기가비트 이더넷 NIC용 드라이버가 들어 있습니다."},{"lang":"cn","x_late":"该组件包可为在 Microsoft Windows Server 2016 下运行的 HPE Intel E1R 千兆以太网卡提供驱动程序。"},{"lang":"ja","x_late":"このコンポーネントパッケージは、Microsoft Windows Server 2016で動作しているHPE Intel E1R Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1196584","datemodified":"2021-08-15T05:23:57","file_list":["cp047043.xml","cpqsetup.exe","cp_data.xml","e1r65x64.cat","e1r65x64.din","e1r65x64.inf","e1r65x64.sys","e1rmsg.dll","install.xml","nicco5.dll","nicdrvr.dll","NicInE1R.dll"],"md5sum":"2300c3300a6f84dddb57fcbcfdb559f5","name":"cp047043.exe","release":"2021-08-15T05:09:28","revision":"0","sha1sum":"7dbfcf31abd104cda2581e04974b5f6cfdd091a2","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec090ca3ac"],"type_of_change":"0","version":"12.16.4.1"}],"id":{"product":"fc4022f2727541aca9a0c50b935a3b24","version":"583c663084fc4dcd936fdb704cc8f37e"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"HPE Intel E1R 驅動程式（適用於 Windows Server 2016）"},{"lang":"en","x_late":"HPE Intel E1R Driver for Windows Server 2016"},{"lang":"ko","x_late":"Windows Server 2016용 HPE Intel E1R 드라이버"},{"lang":"cn","x_late":"适用于 Windows Server 2016 的 HPE Intel E1R 驱动程序"},{"lang":"ja","x_late":"HPE Intel E1Rドライバー for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"3200"},"supported_devices":[{"dev":"1523","subdev":"1989","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1523103c1989","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00FF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1521159000ff","type":"pci","ven":"8086"},{"dev":"1521","subdev":"337F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c337f","type":"pci","ven":"8086"},{"dev":"1521","subdev":"3380","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-1521103c3380","type":"pci","ven":"8086"},{"dev":"1521","subdev":"339E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c339e","type":"pci","ven":"8086"},{"dev":"1521","subdev":"17D1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c17d1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"8157","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c8157","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product contains Windows system update supported improvements.&nbsp;</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product is updated to maintain compatibility with updated Windows installation library NicInE1R.dll and e1rmsg.dll.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"e1r65x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5700-764285-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F4","Version":"2.42.5700"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5056-764283-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F2","Version":"2.42.5056"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5056-764284-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F3","Version":"2.42.5056"},{"DeviceName":"HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5000-764286-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F5","Version":"2.42.5000"},{"DeviceName":"HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5000-764282-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F1","Version":"2.42.5000"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Mellanox VPI (Ethernet and Infiniband mode of operation) adapter firmware on VMware ESXi 7.0"},{"lang":"ja","x_late":"このパッケージは、VMware ESXi 7.0上でHPE Mellanox VPI (EthernetおよびInfinibandモードで動作) アダプターファームウェアをアップグレードするためのユーティリティおよびバイナリを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>InfiniBand Card Type</strong></td>\n\t\t\t<td><strong>Firmware&nbsp;Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+M Adapter (764282-B21)</td>\n\t\t\t<td>2.42.5000</td>\n\t\t\t<td>HP_1350110023</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+M Adapter (764283-B21)</td>\n\t\t\t<td>2.42.5056</td>\n\t\t\t<td>HP_1360110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+QSFP Adapter (764284-B21)</td>\n\t\t\t<td>2.42.5056</td>\n\t\t\t<td>HP_1370110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+FLR-QSFP Adapter (764285-B21)</td>\n\t\t\t<td>2.42.5700</td>\n\t\t\t<td>HP_1380110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+FLR-QSFP Adapter (764286-B21)</td>\n\t\t\t<td>2.42.5000</td>\n\t\t\t<td>HP_1390110023</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"},{"lang":"ja","x_late":"<p>このソフトウェアパッケージは、以下のファームウェアバージョンが含まれています。</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>InfiniBandカードタイプ</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand QDR/Ethernet 10Gb 2ポート544+Mアダプター（764282-B21）</td>\n\t\t\t<td>2.42.5000</td>\n\t\t\t<td>HP_1350110023</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2ポート544+Mアダプター（764283-B21）</td>\n\t\t\t<td>2.42.5056</td>\n\t\t\t<td>HP_1360110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2ポート544+QSFPアダプター（764284-B21）</td>\n\t\t\t<td>2.42.5056</td>\n\t\t\t<td>HP_1370110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2ポート544+FLR-QSFPアダプター（764285-B21）</td>\n\t\t\t<td>2.42.5700</td>\n\t\t\t<td>HP_1380110017 </td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand QDR/Ethernet 10Gb 2ポート544+FLR-QSFPアダプター（764286-B21）</td>\n\t\t\t<td>2.42.5000</td>\n\t\t\t<td>HP_1390110023 </td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"20083186","datemodified":"2021-02-03T03:39:45","file_list":["/CP045904.vmexe64","/CP045904.vmfile","/CP045904_VMw.zip","/CP045904.xml","/payload.json","/README.txt","/CP045904_VMw.zip/index.xml","/CP045904_VMw.zip/vendor-index.xml","/CP045904_VMw.zip/metadata.zip","/CP045904_VMw.zip/vib20/CP045904/HPE_bootbank_CP045904_1.0.0-7.0.0.15525992.vib","/CP045904_VMw.zip/metadata.zip/vendor-index.xml","/CP045904_VMw.zip/metadata.zip/vmware.xml","/CP045904_VMw.zip/metadata.zip/vibs/CP045904--1517099505877222018.xml","/CP045904_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045904_1.0.0-7.0.0.15525992.xml"],"md5sum":"e1a28cdfc099e4a1a327a84a68840576","name":"CP045904.zip","release":"2021-02-26T00:00:00","revision":"1","sha1sum":"ae97d7bab13cb5d0f10c76583ae32cdb3be0b6f7","size":"19MB","target_guids":["a6b1a447-382a-5a4f-15B3-1007103C22F4","a6b1a447-382a-5a4f-15B3-1007103C22F2","a6b1a447-382a-5a4f-15B3-1007103C22F3","a6b1a447-382a-5a4f-15B3-1007103C22F5","a6b1a447-382a-5a4f-15B3-1007103C22F1"],"type_of_change":"1","version":"1.0.1","vib_list":[{"name":"CP045904","version":"1.0.0-7.0.0.15525992"}]}],"id":{"product":"b208c604a379445cb8f4da716ed6946e","version":"2bed7ba28d5f46339c9b9064a2b202d1"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Offline: &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p>\n\n<p>Remote Online, if the component is supported by SUM but is not yet part of an SPP:<br />\n&nbsp; &nbsp; Download the appropriate SPP<br />\n&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />\n&nbsp; &nbsp; Run SUM<br />\n&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />\n&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />\n&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />\n&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />\n&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />\n&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at: <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p>\n\n<p>Note: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p>\n\n<p>To use HPE Insight Control for vCenter: &nbsp;<br />\n&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />\n&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p>\n\n<p>To update firmware from VMware ESXi operating system on target server: &nbsp;<br />\n&nbsp; &nbsp; Enable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Login as root. (You must be root in order to apply the update) &nbsp;<br />\n&nbsp; &nbsp; Place the Smart Component in a temporary directory<br />\n&nbsp; &nbsp; Check if the nmst module is loaded already: vmkload_mod -l | grep nmst<br />\n&nbsp; &nbsp; If module is not loaded, use the command to load the module: vmkload_mod nmst<br />\n&nbsp; &nbsp; From the same directory, execute the Smart Component. For example: unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe<br />\n&nbsp; &nbsp; Follow the directions given by the Smart Component.<br />\n&nbsp; &nbsp; Logout.<br />\n&nbsp; &nbsp; Disable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Reboot your system, if required, for the firmware update to take effect.</p>\n"},{"lang":"ja","x_late":"<p>オフライン：    <br />\n    SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます。</p>\n\n<p>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:<br />\n    適切なSPPをダウンロードします。<br />\n    SPPにコンポーネントを追加します。   <br />\n    アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします<br />\n    SUMを実行します<br />\n    リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します  <br />\n    アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。 <br />\n    ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します  <br />\n    SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。<br />\n    ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います<br />\n    詳細な手順については、SPPのドキュメントを参照してください。<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p>\n\n<p>注記: SUMを使用してファームウェアをアップデートしている間に、レビューページの\"View Devices\"オプションが、アダプター名のリストにありません。これは予測される動作で、コンポーネントの機能に影響を与えません。</p>\n\n<p>HPE Insight Control for vCenterを使用するには、以下の手順に従ってください:  <br />\n    vSphereクライアントにログインします。    <br />\n    インベントリツリーのサーバーまたはクラスターを選択します。 <br />\n    HPE Insight Managementタブをクリックします    <br />\n    HP Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</p>\n\n<p>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。 <br />\n    ESXiホストでSSHを有効にします。<br />\n    rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります)  <br />\n    Smartコンポーネントを一時ディレクトリに置きます<br />\n    nmstモジュールがすでにロードされているかどうかチェックします: vmkload_mod -l | grep nmst<br />\n    モジュールがロードされていない場合、次のコマンドを使用してモジュールをロードします: vmkload_mod nmst<br />\n    同じディレクトリからSmartコンポーネントを実行します。例：unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe<br />\n    Smartコンポーネントの指示に従います。<br />\n    ログアウトします。<br />\n    ESXiホストでSSHを無効にします。<br />\n    必要に応じてシステムを再起動し、ファームウェアのアップデートを有効にします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (ESXi 7.0) for HPE Mellanox VPI (Ethernet and Infiniband mode) devices on VMware ESXi 7.0"},{"lang":"ja","x_late":"オンラインファームウェアアップグレードユーティリティ (ESXi 7.0) for HPE Mellanox VPI (EthernetおよびInfinibandモード) デバイス - VMware ESXi 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-10-17T13:59:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5000:</strong><br />\n&nbsp;&nbsp; &nbsp;764282-B21<br />\n&nbsp;&nbsp; &nbsp;764286-B21&nbsp;&nbsp;</p>\n\n<p><strong>Firmware for the following devices are updated to 2.42.5056:</strong><br />\n&nbsp;&nbsp; &nbsp;764283-B21<br />\n&nbsp;&nbsp;&nbsp;&nbsp;764284-B21</p>\n\n<p><strong>Firmware for the following device&nbsp;is&nbsp;updated to 2.42.5700:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;764285-B21</p>\n\n<p><strong>New features in firmware version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>Added support for the following features.\n\t<ul>\n\t\t<li>new TLV: CX3_GLOBAL_CONF to enable/disable timestamp on incoming packets through mlxconfig configuration.</li>\n\t\t<li>User MAC configuration.</li>\n\t\t<li>Automatically collecting mstdump before driver reset.</li>\n\t\t<li>A&nbsp;mechanism to detect DEAD_IRISC (plastic) from TPT (iron) and raise an assert.</li>\n\t\t<li>A new field is added to &quot;set port&quot; command which notifies the firmware what is the user_mtu size.</li>\n\t</ul>\n\t</li>\n\t<li>Improved the debug ability for command timeout cases.</li>\n</ul>\n\n<p><strong>New features and changes&nbsp;in firmware version 2.42.5700.</strong></p>\n\n<ul>\n\t<li>Modified the mlx_cmd_get_mlx_link_status command return value to return &quot;Link Type = Ethernet&quot; in Ethernet adapter cards.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Fixes in version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>PortRcvPkts counter was prevented from being cleared after&nbsp;resetting it.</li>\n\t<li>The system&nbsp;Timed Out on the configuration cycle of&nbsp;the Virtual Functions (VFs) when more than 10 Virtual Functions&nbsp;performed FLR and the completion Time Out&nbsp;value was configured to a range of less than&nbsp;16 msec.</li>\n\t<li>The server hangs and results in NMI when running&nbsp;&ldquo;mlxfwtop &ndash;d mt4103_pci_cr0&rdquo; while&nbsp;restarting the driver in parallel (from a different&nbsp;thread). In this case, the downstream&nbsp;bridge over the device reported completion&nbsp;timeout error.</li>\n\t<li>In flow_steering,&nbsp;BMC could not receive a ping over&nbsp;IPV6 after running bmc_reboot.</li>\n\t<li>While closing the&nbsp;HCA, the RX packet caused bad access to&nbsp;resources that did not exist, and consequently caused the QPCGW or the irisc to get stuck.</li>\n\t<li>The master SMLID&nbsp;and the LID was either 0 or&nbsp;0xFFFF when the port was neither active nor&nbsp;armed.</li>\n\t<li>ibdump could not capture&nbsp;all MADs packets.</li>\n\t<li>link did not&nbsp;go up after reboot.</li>\n\t<li>Fixed a rare issue that cause the PCIe&nbsp;configuration cycle that arrived during the&nbsp;time of sw_reset to generate 2 completions.</li>\n\t<li>Network Controller Sideband Interface (NC-SI) did not&nbsp;work when adding the disable_static_steering_ini field in the ini file, due to&nbsp;memory allocation issue for this field in the&nbsp;scratchpad.</li>\n</ul>\n\n<p><strong>Fixes in version 2.42.5056:</strong></p>\n\n<ul>\n\t<li>Fixed an issue that resulted in reading from invalid I/O address on handover from UEFI boot to OS boot, when a port was configured as InfiniBand on a VPI adapter device.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5000:</strong><br />\n&nbsp;&nbsp; &nbsp;764282-B21<br />\n&nbsp;&nbsp; &nbsp;764286-B21&nbsp;&nbsp;</p>\n\n<p><strong>Firmware for the following devices are updated to 2.42.5056:</strong><br />\n&nbsp;&nbsp; &nbsp;764283-B21<br />\n&nbsp;&nbsp;&nbsp;&nbsp;764284-B21</p>\n\n<p><strong>Firmware for the following device&nbsp;is&nbsp;updated to 2.42.5700:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;764285-B21</p>\n\n<p><strong>New features in firmware version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>Added support for the following features.\n\t<ul>\n\t\t<li>new TLV: CX3_GLOBAL_CONF to enable/disable timestamp on incoming packets through mlxconfig configuration.</li>\n\t\t<li>User MAC configuration.</li>\n\t\t<li>Automatically collecting mstdump before driver reset.</li>\n\t\t<li>A&nbsp;mechanism to detect DEAD_IRISC (plastic) from TPT (iron) and raise an assert.</li>\n\t\t<li>A new field is added to &quot;set port&quot; command which notifies the firmware what is the user_mtu size.</li>\n\t</ul>\n\t</li>\n\t<li>Improved the debug ability for command timeout cases.</li>\n</ul>\n\n<p><strong>New features and changes&nbsp;in firmware version 2.42.5700.</strong></p>\n\n<ul>\n\t<li>Modified the mlx_cmd_get_mlx_link_status command return value to return &quot;Link Type = Ethernet&quot; in Ethernet adapter cards.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Fixes in version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>PortRcvPkts counter was prevented from being cleared after&nbsp;resetting it.</li>\n\t<li>The system&nbsp;Timed Out on the configuration cycle of&nbsp;the Virtual Functions (VFs) when more than 10 Virtual Functions&nbsp;performed FLR and the completion Time Out&nbsp;value was configured to a range of less than&nbsp;16 msec.</li>\n\t<li>The server hangs and results in NMI when running&nbsp;&ldquo;mlxfwtop &ndash;d mt4103_pci_cr0&rdquo; while&nbsp;restarting the driver in parallel (from a different&nbsp;thread). In this case, the downstream&nbsp;bridge over the device reported completion&nbsp;timeout error.</li>\n\t<li>In flow_steering,&nbsp;BMC could not receive a ping over&nbsp;IPV6 after running bmc_reboot.</li>\n\t<li>While closing the&nbsp;HCA, the RX packet caused bad access to&nbsp;resources that did not exist, and consequently caused the QPCGW or the irisc to get stuck.</li>\n\t<li>The master SMLID&nbsp;and the LID was either 0 or&nbsp;0xFFFF when the port was neither active nor&nbsp;armed.</li>\n\t<li>ibdump could not capture&nbsp;all MADs packets.</li>\n\t<li>link did not&nbsp;go up after reboot.</li>\n\t<li>Fixed a rare issue that cause the PCIe&nbsp;configuration cycle that arrived during the&nbsp;time of sw_reset to generate 2 completions.</li>\n\t<li>Network Controller Sideband Interface (NC-SI) did not&nbsp;work when adding the disable_static_steering_ini field in the ini file, due to&nbsp;memory allocation issue for this field in the&nbsp;scratchpad.</li>\n</ul>\n\n<p><strong>Fixes in version 2.42.5056:</strong></p>\n\n<ul>\n\t<li>Fixed an issue that resulted in reading from invalid I/O address on handover from UEFI boot to OS boot, when a port was configured as InfiniBand on a VPI adapter device.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_VPI","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The Smart Storage Administrator Diagnostic Utility CLI is a commandline-based disk configuration program for Smart Array and SmartRAID Controllers and any supported devices, including providing SmartSSD Wear Gauge information for supported drives."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"4275764","datemodified":"2021-08-11T13:16:58","file_list":["./opt/smartstorageadmin/ssaducli","./opt/smartstorageadmin/ssaducli/README.TXT","./opt/smartstorageadmin/ssaducli/bin","./opt/smartstorageadmin/ssaducli/bin/ssaducli","./opt/smartstorageadmin/ssaducli/bin/ssaduesxi","./opt/smartstorageadmin/ssaducli/bin/upgrade.txt","./opt/smartstorageadmin/ssaducli/ssadu.license","./usr/man/man8/ssaducli.8.gz","./usr/sbin/ssaducli","./usr/share/smartupdate/ssaducli/component.xml"],"md5sum":"11137e1ba70eed54b5f890945ba60d19","name":"ssaducli-5.20-8.0.x86_64.rpm","release":"2021-08-11T13:12:11","revision":"0","sha1sum":"b70c5aa3d2ca320d9cd32a827152c86b8577df17","size":"4MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec9fb103be"],"type_of_change":"1","version":"5.20.8.0"}],"id":{"product":"7a0e2103ab3d449ea173c873ce94c871","version":"cb044e3153754d20b14bcbc731df6aa0"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<ul>\n\t<li>SSADUCLI is distributed using Red Hat Package Manager (RPM) packages.</li>\n\t<li>If there is an older version of SSADUCLI installed on the system, please use &quot;rpm -e ssacli&quot; to remove it first.</li>\n\t<li>Use &quot;rpm -i &lt;file name&gt;&quot; to install the application.</li>\n\t<li>Please type &quot;man rpm&quot; for other details regarding RPM.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Linux (64 位元) 的 Smart Storage Administrator Diagnostic Utility (SSADU) CLI"},{"lang":"en","x_late":"Smart Storage Administrator Diagnostic Utility (SSADU) CLI for Linux 64-bit"},{"lang":"ko","x_late":"Linux 64비트용 스마트 스토리지 관리자 진단 유틸리티(SSADU) CLI"},{"lang":"cn","x_late":"64位Linux版Smart Storage Administrator Diagnostic Utility (SSADU) CLI"},{"lang":"ja","x_late":"Smart Storage Administrator Diagnostic Utility (SSADU) CLI for Linux 64ビット"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-09T05:30:43","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added&nbsp;support&nbsp;to the HPE&nbsp;SR932i-p and SR416-a&nbsp;Gen10+&nbsp;Controllers.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U38","value":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"key":"U38","value":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"key":"","value":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"Carbondale14","value":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U14","value":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4520 Gen9 Chassis</p>\n"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"","value":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U27","value":"HPE ProLiant XL2x260w Gen9 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>\n"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"","value":"HPE ProLiant ML150 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"","value":"HPE ProLiant XL770f Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"ssaducli","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000960JWSSQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304a57535351","Version":"HPD8"},{"DeviceName":"VK001920JWSSR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304a57535352","Version":"HPD8"},{"DeviceName":"VK003840JWSST","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304a57535354","Version":"HPD8"},{"DeviceName":"VK007680JWSSU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-304a57535355","Version":"HPD8"},{"DeviceName":"VO015300JWSSV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3330-304a57535356","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK000960JWSSQ, VK001920JWSSR, VK003840JWSST, VK007680JWSSU and VO015300JWSSV"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VK000960JWSSQ、VK001920JWSSR、VK003840JWSST、VK007680JWSSUおよびVO015300JWSSV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VK000960JWSSQ, VK001920JWSSR, VK003840JWSST, VK007680JWSSU and VO015300JWSSV&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5177284","datemodified":"2021-07-23T09:44:03","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-1e51a57347-HPD8-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-1e51a57347-HPD8-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-1e51a57347-HPD8-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-1e51a57347-HPD8-5.1/CP048211.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-1e51a57347-HPD8-5.1/GPM1643SAMD8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-1e51a57347-HPD8-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-1e51a57347-HPD8-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-1e51a57347-HPD8-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-1e51a57347-HPD8-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048211.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048211.scexe"],"md5sum":"0207d02b65ded1d7997a33f7ad468a03","name":"firmware-hdd-1e51a57347-HPD8-5.1.x86_64.rpm","release":"2021-07-23T09:31:14","revision":"0","sha1sum":"5196e1ef522d20c25ddbe80e4d1040af2304c4c2","size":"4MB","target_guids":["562340a5-304b-3030-3936-304a57535351","562340a5-304b-3130-3932-304a57535352","562340a5-304b-3330-3834-304a57535354","562340a5-304b-3730-3638-304a57535355","562340a5-304f-3531-3330-304a57535356"],"type_of_change":"2","version":"HPD8"}],"id":{"product":"36bcc8676cfa4135862a614c063902e6","version":"510c3d95562d4e02a4bde7d1d1cb9060"},"installation":{"command":"CP042632.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK000960JWSSQ, VK001920JWSSR, VK003840JWSST, VK007680JWSSU and VO015300JWSSV Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) -VK000960JWSSQ、 VK001920JWSSR、VK003840JWSST、VK007680JWSSUおよびVO015300JWSSVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VO015300JWSSV","target_guid":"562340a5-304f-3531-3330-304a57535356","type":"sas"},{"id":"VK007680JWSSU","target_guid":"562340a5-304b-3730-3638-304a57535355","type":"sas"},{"id":"VK003840JWSST","target_guid":"562340a5-304b-3330-3834-304a57535354","type":"sas"},{"id":"VK001920JWSSR","target_guid":"562340a5-304b-3130-3932-304a57535352","type":"sas"},{"id":"VK000960JWSSQ","target_guid":"562340a5-304b-3030-3936-304a57535351","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T11:56:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK001920JWSSR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO015300JWSSV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VK000960JWSSQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VK003840JWSST","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VK007680JWSSU","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains iSCSI drivers for the HPE Emulex 10/20GbE Server Adapters running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 8で動作するHPE Emulex 10/20GbE サーバーアダプター用のiSCSIドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1230032","datemodified":"2021-01-14T07:44:34","file_list":["./etc/depmod.d/be2iscsi.conf","./lib/modules/4.18.0-193.el8.x86_64","./lib/modules/4.18.0-193.el8.x86_64/extra","./lib/modules/4.18.0-193.el8.x86_64/extra/be2iscsi","./lib/modules/4.18.0-193.el8.x86_64/extra/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/kmod-be2iscsi/component.xml"],"md5sum":"41e355e8d3c84b3255ceef5737a6ffef","name":"kmod-be2iscsi-12.0.1342.0-1.rhel8u2.x86_64.rpm","release":"2021-01-14T07:31:04","revision":"0","sha1sum":"7fc9eff00e5853ddd7706d1f9bda348745a7bef5","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd9057dd3"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"1265721","datemodified":"2021-01-14T07:37:34","file_list":["./etc/depmod.d/be2iscsi.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/be2iscsi","./lib/modules/4.18.0-240.el8.x86_64/extra/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/kmod-be2iscsi/component.xml"],"md5sum":"b3b83ef2621c73df7709acc7b11c91ad","name":"kmod-be2iscsi-12.0.1342.0-1.rhel8u3.x86_64.rpm","release":"2021-01-14T07:31:04","revision":"0","sha1sum":"9400144fadc091f44fbc6b9e2738f3130fc5c6f4","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd9057dd3"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"da2886f50e85443fa3f87dcf733edc2b","version":"74cd88bdfbf54bf5bd8c1cc53129ec38"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Emulex 10/20GbE iSCSI Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE Emulex 10/20GbE iSCSIドライバー for Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0728","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c8144","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c21d4","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072215908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c220a","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 8 Update 2 and&nbsp;Red Hat Enterprise Linux 8 Update 3</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"kmod-be2iscsi","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2iscsi","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2iscsi","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2iscsi","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000JEQUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHC8SDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a45515556","Version":"HPDB"},{"DeviceName":"MB8000JEQVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHC8SDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3842-3030-304a45515641","Version":"HPDB"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB6000JEQUV and MB8000JEQVA"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MB6000JEQUVおよびMB8000JEQVA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB6000JEQUV and MB8000JEQVA Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDB<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD9<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"17484913","datemodified":"2021-08-27T04:18:11","file_list":["/CP048378_BUILD_2.data","/CP048378.vmexe","/CP048378.vmexe64","/CP048378.vmfile","/CP048378_VMw.zip","/CP048378.xml","/payload.json","/CP048378_VMw.zip/index.xml","/CP048378_VMw.zip/vendor-index.xml","/CP048378_VMw.zip/metadata.zip","/CP048378_VMw.zip/vib20/CP048378/HPE_bootbank_CP048378_HPDB.2-7.0.0.15843807.vib","/CP048378_VMw.zip/metadata.zip/vendor-index.xml","/CP048378_VMw.zip/metadata.zip/vmware.xml","/CP048378_VMw.zip/metadata.zip/vibs/CP048378-272077702656427524.xml","/CP048378_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048378_HPDB.2-7.0.0.15843807.xml"],"md5sum":"b3a831515a3f2a435ef897282b89f0df","name":"CP048378.zip","release":"2021-08-27T04:12:50","revision":"0","sha1sum":"e73b8757b6df813efd138240649b31edee22f486","size":"16MB","target_guids":["002340a5-4d00-3642-3030-304a45515556","002340a5-4d00-3842-3030-304a45515641"],"type_of_change":"1","version":"HPDB","vib_list":[{"name":"CP048378","version":"HPDB.2-7.0.0.15843807"}]}],"id":{"product":"1d0e9b382f8640e89092917ac97996ce","version":"70460be367f946b3aa379f828104ac98"},"installation":{"command":"CP040519.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - MB6000JEQUV and MB8000JEQVA Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi  - MB6000JEQUV およびMB8000JEQVAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB6000JEQUV","target_guid":"002340a5-4d00-3642-3030-304a45515556","type":"sas"},{"id":"MB8000JEQVA","target_guid":"002340a5-4d00-3842-3030-304a45515641","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T07:33:16","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB8000JEQVA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB6000JEQUV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for HPE Intel Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Intel NICs Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"3466734","datemodified":"2021-08-24T17:05:13","file_list":["./etc/depmod.d/hp-igb.conf","./etc/dracut.conf.d/hp-igb-oob.conf","./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/hp-igb","./lib/modules/5.3.18-22-default/updates/hp-igb/igb.ko","./usr/share/smartupdate/hp-igb-kmp-default/component.xml"],"md5sum":"1ad2efea7879fb4132c3fecdbc04a4c9","name":"hp-igb-kmp-default-6.7.2_k5.3.18_22-2.sles15sp2.x86_64.rpm","release":"2021-08-24T16:47:05","revision":"0","sha1sum":"fa6398aa90bbaf5b950d84031eff0866805bab46","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec7f45f646"],"type_of_change":"0","version":"6.7.2-2"},{"bytes":"3574729","datemodified":"2021-08-24T17:02:24","file_list":["./etc/depmod.d/hp-igb.conf","./etc/dracut.conf.d/hp-igb-oob.conf","./lib/modules/5.3.18-57-default","./lib/modules/5.3.18-57-default/updates","./lib/modules/5.3.18-57-default/updates/hp-igb","./lib/modules/5.3.18-57-default/updates/hp-igb/igb.ko","./usr/share/smartupdate/hp-igb-kmp-default/component.xml"],"md5sum":"e49d0499804712969d4b06267f55800c","name":"hp-igb-kmp-default-6.7.2_k5.3.18_57-2.sles15sp3.x86_64.rpm","release":"2021-08-24T16:47:05","revision":"0","sha1sum":"56bc418ee0b5b61aaabf68a8faf6212d3eb73aed","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec7f45f646"],"type_of_change":"0","version":"6.7.2-2"}],"id":{"product":"a162b7594d8d4a02bf2f3f7d9fe2609d","version":"65bbb4bbb1804571ac74de6f2eed8acf"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"},{"lang":"ja","x_late":"<p>インストールのノートについてREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Intel igb Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE Intel igbドライバーfor SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1523","subdev":"1989","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1523103c1989","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00FF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1521159000ff","type":"pci","ven":"8086"},{"dev":"1521","subdev":"337F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c337f","type":"pci","ven":"8086"},{"dev":"1521","subdev":"339E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c339e","type":"pci","ven":"8086"},{"dev":"1521","subdev":"17D1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c17d1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"3380","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-1521103c3380","type":"pci","ven":"8086"},{"dev":"1521","subdev":"8157","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c8157","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00A3","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a3","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>This product now support HPE Intel Online Firmware Upgrade Utility for Linux x86_64, version (or later) to update firmware</li>\n\t<li>This product now supports Suse Linux Enterprise Server 15 Service Pack 2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>This product now supports Linux Firmware upgrade utility v.1.22.5</li>\n\t<li>This product now supports&nbsp;SUSE Linux Enterprise Server 15 Service Pack 3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"hp-igb-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-igb-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-igb-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-igb-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This driver, LSI_SAS2, provides Windows Server 2016 support for HPE H2xx SAS/SATA Host Bus Adapter. "},{"lang":"ja","x_late":"このLSI_SAS2ドライバーは、HPEドライバーH2xx SAS/SATAホストバスアダプター対応のWindows Server 2016サポートを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"1513232","datemodified":"2018-09-28T00:45:55","file_list":["cp037731.xml","cpqsetup.exe","driverconfigparam.def","generic.dll","install.xml","lsinodrv.inf","lsi_sas2.cat","lsi_sas2.inf","lsi_sas2.pdb","lsi_sas2.sys","lsi_sas2_win10_vNext.txt","user guide - windows driver configuration utility.pdf","wdcfg.exe"],"md5sum":"ad9ca644816eb28c67640637713c912f","name":"cp037731.exe","release":"2018-09-28T05:45:03","revision":"0","sha1sum":"6757abdfed6a1a6de3cd854b3cf7d9ac1b51e0fc","size":"1MB","target_guids":[],"type_of_change":"0","version":"2.68.64.2"}],"id":{"product":"8d193d8d218443f6b0fa9476dd4e1562","version":"bb7e74123df640a0a8d37e579daf5ada"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n"},{"lang":"ja","x_late":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"LSI Logic Corporation"}],"name":[{"lang":"en","x_late":"HPE H2xx SAS/SATA Host Bus Adapter Driver for 64-bit Microsoft Windows Server 2016 Editions"},{"lang":"ja","x_late":"HPE H2xx SAS/SATAホストバスアダプタードライバーfor 64-bit Microsoft Windows Server 2016 Edition"}],"prerequisites":{"required_diskspace":{"size_kb":"1440"},"supported_devices":[{"dev":"0087","subdev":"0042","subven":"1590","target_guid":"","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-10-28T05:19:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p style=\"margin-left:.1in\"><strong>Change implemented in version 2.68.64.2(B)</strong>:</p>\n\n<ul>\n\t<li>Updated to support Service Pack for ProLiant version 2017.07.0.<br />\n\t<strong>Note:</strong> If component version 2.68.64.2(A) was previously installed, then it is not necessary to upgrade to version 2.68.64.2(B).</li>\n</ul>\n\n<p style=\"margin-left:.1in\"><strong>Enhancements/New Features implemented in version 2.68.64.2(A)</strong>:</p>\n\n<p style=\"margin-left:.2in\">Added support for:</p>\n\n<ul>\n\t<li>Microsoft Windows Server 2016 - Server Core and Server with a Desktop.</li>\n\t<li>Revised component package. No change to driver functionality resulting from the change. If system has previously updated to driver version 2.68.64.2, then it is not necessary to update to 2.68.64.2(A).</li>\n</ul>\n\n<p style=\"margin-left:1.0in\">&nbsp;</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Improved integration with Smart Update Manager</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"}],"sw_keys":[{"name":"lsi_sas2.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWRTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLPeAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57525444","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB008000JWRTD"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB008000JWRTD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB008000JWRTD Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD1<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp; </strong>None</p>\n"}],"files":[{"bytes":"4171776","datemodified":"2021-07-23T11:54:11","file_list":["cp048670.xml","cpqsetup.exe","HVLPeAsseFD2.rel","payload.json","setup.dll"],"md5sum":"68561745771c7137ac47211bd3e00524","name":"cp048670.exe","release":"2021-07-23T11:47:11","revision":"0","sha1sum":"a6dfebee149d0f256285fe1ea6b56072f6c1be2f","size":"3MB","target_guids":["4d2340a5-3042-3830-3030-304a57525444"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"3f71b29f23c14fcb8f1f4cc9ac53400c","version":"503db59efcd746638f169d03cfc3bdb9"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB008000JWRTD Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB008000JWRTD ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB008000JWRTD","target_guid":"4d2340a5-3042-3830-3030-304a57525444","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-17T08:21:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000JWRTD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 adapter cards."},{"lang":"ja","x_late":"このRPMには、サポートされているHPE Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 アダプターカード用のHPEによるテストと承認済みのLinuxベースMellanox RoCE (RDMA over Converged Ethernet)ドライバーが含まれます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1543188","datemodified":"2021-07-21T06:58:55","file_list":["./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/compat","./lib/modules/4.12.14-94.41-default/updates/compat/mlx_compat.ko","./lib/modules/4.12.14-94.41-default/updates/drivers","./lib/modules/4.12.14-94.41-default/updates/drivers/base","./lib/modules/4.12.14-94.41-default/updates/drivers/base/auxiliary.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/ib_cm.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/ib_core.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/ib_ucm.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/ib_umad.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/iw_cm.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/rdma_cm.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/cxgb3","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/cxgb3/iw_cxgb3.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/cxgb4","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/efa","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/efa/efa.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/hfi1","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/i40iw","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/mlx4","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/mlx5","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/mthca","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/mthca/ib_mthca.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/nes","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/nes/iw_nes.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/ocrdma","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/ocrdma/ocrdma.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/qedr","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/qib","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/qib/ib_qib.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/usnic","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/sw","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/sw/rdmavt","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/sw/rxe","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/ipoib","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/iser","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/isert","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/opa_vnic","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/srp","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/srpt","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/net","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlx5","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/nvme","./lib/modules/4.12.14-94.41-default/updates/drivers/nvme/host","./lib/modules/4.12.14-94.41-default/updates/drivers/nvme/host/nvme-rdma.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/nvme/target","./lib/modules/4.12.14-94.41-default/updates/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/4.12.14-94.41-default/updates/net","./lib/modules/4.12.14-94.41-default/updates/net/9p","./lib/modules/4.12.14-94.41-default/updates/net/9p/9pnet_rdma.ko","./lib/modules/4.12.14-94.41-default/updates/net/rds","./lib/modules/4.12.14-94.41-default/updates/net/rds/rds_rdma.ko","./lib/modules/4.12.14-94.41-default/updates/net/sunrpc","./lib/modules/4.12.14-94.41-default/updates/net/sunrpc/xprtrdma","./lib/modules/4.12.14-94.41-default/updates/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/4.12.14-94.41-default/updates/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/4.12.14-94.41-default/updates/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/mlnx-ofa_kernel-kmp-default/component.xml"],"md5sum":"17386b357b7e2688f58838e247bcb15e","name":"mlnx-ofa_kernel-kmp-default-5.4_k4.12.14_94.41-OFED.5.4.1.0.3.1.sles12sp4.x86_64.rpm","release":"2021-07-21T05:49:10","revision":"0","sha1sum":"9e5fae129458c04a3eab66d55302a70f0b799877","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"5.4"},{"bytes":"1270989","datemodified":"2021-07-21T06:57:24","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/rdma","./etc/rdma/mlx4.conf","./etc/rdma/modules","./etc/rdma/modules/rdma.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/70-persistent-ipoib.rules","./lib/udev/auxdev-sf-netdev-rename","./lib/udev/mlnx_bf_udev","./lib/udev/rules.d/82-net-setup-link.rules","./lib/udev/rules.d/83-mlnx-sf-name.rules","./lib/udev/rules.d/90-ib.rules","./lib/udev/sf-rep-netdev-rename","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/mlnx_bf_configure_ct","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_perf","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/include/mellanox/dpcp.h","./usr/lib/dracut","./usr/lib/dracut/modules.d","./usr/lib/dracut/modules.d/05rdma","./usr/lib/dracut/modules.d/05rdma/module-setup.sh","./usr/lib/mlx4-setup.sh","./usr/lib/modprobe.d","./usr/lib/modprobe.d/libmlx4.conf","./usr/lib/python2.7/site-packages/dcbnetlink.py","./usr/lib/python2.7/site-packages/dcbnetlink.pyc","./usr/lib/python2.7/site-packages/dcbnetlink.pyo","./usr/lib/python2.7/site-packages/genetlink.py","./usr/lib/python2.7/site-packages/genetlink.pyc","./usr/lib/python2.7/site-packages/genetlink.pyo","./usr/lib/python2.7/site-packages/mlnx_tools-5.2.0-py2.7.egg-info","./usr/lib/python2.7/site-packages/netlink.py","./usr/lib/python2.7/site-packages/netlink.pyc","./usr/lib/python2.7/site-packages/netlink.pyo","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/rdma-ndd.service","./usr/lib/systemd/system/vma.service","./usr/lib/udev/rdma_rename","./usr/lib/udev/rules.d","./usr/lib/udev/rules.d/60-rdma-ndd.rules","./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules","./usr/lib/udev/rules.d/75-rdma-description.rules","./usr/lib/udev/rules.d/90-rdma-umad.rules","./usr/lib64/libdpcp.so","./usr/lib64/libdpcp.so.1","./usr/lib64/libdpcp.so.1.1.12","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.35.0","./usr/lib64/libibverbs","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.14.35.0","./usr/lib64/libibverbs/libmlx5-rdmav34.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.19.35.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.3.35.0","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.3.1","./usr/lib64/rsocket","./usr/lib64/rsocket/librspreload.so","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/ibdev2netdev","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/rdma-ndd","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vmad","./usr/share/doc/packages/dpcp","./usr/share/doc/packages/dpcp/README","./usr/share/doc/packages/libibverbs","./usr/share/doc/packages/libibverbs/libibverbs.md","./usr/share/doc/packages/librdmacm","./usr/share/doc/packages/librdmacm/librdmacm.md","./usr/share/doc/packages/libvma-9.3.1","./usr/share/doc/packages/libvma-9.3.1/CHANGES","./usr/share/doc/packages/libvma-9.3.1/README","./usr/share/doc/packages/mlnx-tools","./usr/share/doc/packages/mlnx-tools/ib2ib_setup.txt","./usr/share/doc/packages/rdma-core","./usr/share/doc/packages/rdma-core/COPYING.BSD_FB","./usr/share/doc/packages/rdma-core/COPYING.BSD_MIT","./usr/share/doc/packages/rdma-core/COPYING.GPL2","./usr/share/doc/packages/rdma-core/COPYING.md","./usr/share/doc/packages/rdma-core/README.md","./usr/share/doc/packages/rdma-core/tag_matching.md","./usr/share/doc/packages/rdma-core/udev.md","./usr/share/man/man7/rsocket.7.gz","./usr/share/man/man7/vma.7.gz","./usr/share/man/man8/ib2ib_setup.8.gz","./usr/share/man/man8/rdma-ndd.8.gz","./usr/share/man/man8/vmad.8.gz","./usr/share/mlnx_ofed/mlnx_bf_assign_ct_cores.sh","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml"],"md5sum":"1800c3f8b54ee8707115c5108a8a0cf1","name":"mlnx-ofa_kernel-5.4-OFED.5.4.1.0.3.1.sles12sp4.x86_64.rpm","release":"2021-07-21T05:49:10","revision":"0","sha1sum":"84e2039c22d3d9b01a0994bcccb7788d3253ac0c","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"5.4"}],"id":{"product":"1f96d5ce1b7c4e7fae4a08d7d5e4898d","version":"541ae48119484601b31b2b297c45b9a0"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"11.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPMs to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-5.4&quot; RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using 4.12.14-94.41-default kernel or any future errata:<br />\n<br />\n<strong># rpm -Uvh&nbsp;mlnx-ofa_kernel-5.4-OFED.5.4.0.5.1.1.sles12sp4.x86_64.rpm mlnx-ofa_kernel-kmp-default-5.4_k4.12.14_94.41-OFED.5.4.0.5.1.1.sles12sp4.x86_64.rpm</strong><br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 Adapters for SUSE LINUX Enterprise Server 12 SP4 (AMD64/EM64T)"},{"lang":"ja","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet)ドライバーfor Mellanox ConnectX-4、ConnectX-5、ConnectX-6 Adapters for SUSE LINUX Enterprise Server 12 SP4 (AMD64/EM64T)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"101f","subdev":"0012","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30012","type":"pci","ven":"15b3"},{"dev":"101f","subdev":"0007","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30007","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"032D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-10171590032d","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T17:11:54","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Changes and new features in HPE Mellanox RoCE driver&nbsp;version 5.2:</strong></p>\n\n<p><strong>For ConnectX-5 Adapters and above:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>CQE compression support for Rx multi-strides packets.</li>\n\t\t<li>Configuring QoS on a single QP or on a group of QPs.</li>\n\t\t<li>Encap/decap hardware offload of IPv4 traffic over MPLS-over-UDP. This can be used in networks with MPLS routers to achieve more efficient routing.</li>\n\t\t<li>Connection tracking rules on VFs to forward traffic from one VF to the other.</li>\n\t\t<li>Offloading sFlow sampling rules.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For ConnectX-5 Adapters and ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>A locking mechanism to enable parallel insertion of rules into the software steering using the mlx5dv_dr API. The parallel insertion improves the insertion rate and takes place when adding Rx and Tx rules via the FDB domain.</li>\n\t\t<li>Option to match mlx5dv_dr API on Geneve tunnel using a dynamic flex parser. The option header consists of class, type, length and data. The parser should be configured using devx command, after which a rule can be created to match on parser ID and data.</li>\n\t\t<li>Geneve tunneling offload, including matching on extension header.</li>\n\t\t<li>Parallel insertion and deletion of offloaded rules using multiple&nbsp;OVS threads.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>[Beta] Modify GTP-U TEID. This support requires flex parser&nbsp;configuration.</li>\n\t\t<li>[Beta] Improved performance of OVS Connection Tracking flows by&nbsp;enabling the merge of the multi-table flow matches and actions into one joint flow.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Dx Adapters and above:</strong></p>\n\n<p>Added support for the following features:</p>\n\n<ul>\n\t<li>Transmitted packet timestamping accuracy can be improved when using a timestamp generated at the port level instead of a timestamp generated upon CQE creation. Tx port time-stamping better reflects the actual time of a packet&#39;s transmission. This feature is disabled by default. The feature can be enabled or disabled using the following command. ethtool --set-priv-flags tx_port_ts on / off.</li>\n\t<li>Offloading tunnel rules when the source interface is VF (in addition to uplink) in the Hypervisor.</li>\n\t<li>Using Mirroring Offload with Connection Tracking.</li>\n\t<li>ASO flow meter using the mlx5dv_dr API, which allows for monitoring the packet rate for specific flows. When a packet hits a flow that is connected to a flow meter, the rate of packets through this meter is evaluated, and the packet is marked with a color copied into one of the C registers, according to the current rate compared to the reference rate.</li>\n\t<li>ASO first hit using the mlx5dv_dr API, which allows for tracking rule hits by packets. When a packet hits a rule with the ASO first hit action, a flag is set indicating this event, and the original value of the flag is copied to one of the C registers.</li>\n\t<li>mlx5dv_dr API support for matching on a new field &quot;gtpu_first_ext_dw_0&quot;. This field enables packet filtering based on the GTP-U first extension header (first dword only). To enable parsing of tunnel GTP-U extension header, run the following command. ./cloud_fw_reset.py FLEX_PARSER_PROFILE_ENABLE=3.</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Lx Adapters and above:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>IPsec full offload support for extended sequence number, replay protection window and lifetime packet limit.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;All HCA&#39;s:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>New query GID API that allows for querying a single GID entry by its port and GID index, or querying for all GID tables of a specific device. This API works over ioctl instead of sysfs, which accelerates the querying process.</li>\n\t\t<li>Performing multi-host firmware reset in order to upgrade the device firmware. Firmware reset loads the new firmware in case it was burnt on the flash and was pending activation, and reload.</li>\n\t\t<li>[Alpha] Firmware live patching in the driver. Live patching updates the firmware without the need to perform firmware reset. However, it can only be applied in scenarios where the difference between the current and new firmware versions are minor, which is decided upon by the firmware itself.</li>\n\t\t<li>devlink tool for performing firmware reset in order to upgrade the device firmware. Firmware reset loads the new firmware in case it was burnt on the flash and was pending activation, and reloads the current firmware image from the flash in case no new firmware was pending. For further information, please refer to the the devlink man page.</li>\n\t\t<li>A resiliency mechanism for the driver to manually poll the command event queue (EQ) in case of a command timeout. In case the resiliency mechanism finds unhandled event queue entry (EQE) due to a lost interrupt, the driver will handle it, after which the command interface returns to a healthy state.</li>\n\t\t<li>Setting a sniffer private flag is deprecated and no longer required. In order to capture offloaded/RoCE traffic, tcpdump can now be run on the RDMA device.</li>\n\t\t<li>Added per-port reporters to devlink health to manage per-port health activities. Users can now access the devlink port reporters by specifying the port index in addition to the device devlink name through the devlink health commands API. This update was first introduced in iproute2 v5.8. As part of this feature, mlx5e Tx and Rx reporters are now redefined as devlink port reporters. For examples, please see devlink-health manpage</li>\n\t\t<li>Optimized memory consumption of memory registration in huge page systems. As an example, in a 2MB huge page system, 600 MB would be saved for 100 GB memory registration.</li>\n\t\t<li>mlx5dv API to modify the configured UDP source port for RoCE packets of a given RC/UC QP when QP is in RTS state.</li>\n\t\t<li>Accelerating Tx datapath by saving PCI bandwidth and CPU utilization. The savings are achieved by aggregating multiple packets into a single WQE. The feature is driven by xmit_more for certain traffic types, such as UDP.</li>\n\t</ul>\n\t</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 5.2:</strong></p>\n\n<ul>\n\t<li>Clearing min_rate on all SR-IOV legacy VFs after setting min_rate to at least one of the VFs did not disable QoS min_rate.</li>\n\t<li>An empty /usr/src/mlnx-ofa_kernel/default is now no longer created.</li>\n\t<li>An issue where installing packages through a repository failed after generation of metapackages using --add-kernel-support. The failure occurred due to excessive and incorrect Obsolete headers in those metapackages.Enabled installation of mlnx-ofa_kernel package to /bin/python3 instead of / usr/bin/python3 on RHEL 8.x systems.</li>\n\t<li>All IPoIB offload packets were wrongly counted as rx_csum_complete. These packets are now identified as rx_csum_unnecessary packets.</li>\n\t<li>mlx5dv_dr_rule_destroy segmentation fault could happen in rare cases with multiple rules on the same matcher with a different number of actions. This could happen after reusing an already deleted rule memory with less actions.</li>\n\t<li>An issue of moving to SwitchDev mode after configuring DSCP (Differentiated Service Code Point).</li>\n\t<li>Global traffic class configuration did not take effect on DC QPs (Dynamically Connected Queue Pairs).</li>\n\t<li>ib_send_bw traffic frequently dropped to zero when RDMA CM was used, because of incorrect&nbsp;min_rnr_timer setting on the responder side. The min_rnr_timer setting is now aligned with the setting in non-RDMA CM cases.</li>\n\t<li>Traffic did not pass over VFs with VST QinQ feature is enabled.</li>\n\t<li>When traffic was sent over Geneve VLAN with Tx VLAN offload enabled and TSO (TCP Segmentation Offload)&nbsp;or Tx csum enabled, traffic could be dropped and not sent to the wire.</li>\n\t<li>An issue that caused the firmware to restart upon installing mlnxofed-dpdk-upstream-libs package manually.</li>\n\t<li>Bad utility paths in rdma-core &quot;dracut&quot; hooks on SLES systems, which used to result in the following errors when running &quot;dracut&quot; with the &quot;--add rdma&quot; option. dracut-install:\n\t<ul>\n\t\t<li>ERROR: installing &lsquo;/usr/libexec/mlx4-setup.sh&rsquo; dracut: /usr/lib/dracut/dracut-install -D /var/tmp/dracut.UdCOSJ/ initramfs /usr/libexec/mlx4-setup.sh dracut-install: ERROR: installing &lsquo;/usr/libexec/rdma-set-sriov-vf&rsquo; dracut: /usr/lib/dracut/dracut-install -D /var/tmp/dracut.UdCOSJ/ initramfs /usr/libexec/rdma-set-sriov-vf</li>\n\t</ul>\n\t</li>\n\t<li>Traffic class value was not updated in DCT when set via sysfs.</li>\n\t<li>A doorbell loss issue on AMD platforms with Secure Memory Encryption (SME).</li>\n\t<li>Registering memory using mlx5dv_devx_umem_reg while forking. Without this fix, applications which use fork() or similar syscalls while using a memory registered with umem_reg could hang due to incorrect physical page mapping. This fix requires setting the IBV_FORK_SAFE environment variable.</li>\n\t<li>When&nbsp;unbinding the device resulted in the following message being printed to the dmesg: &quot;failed to disable DC tracer&quot;</li>\n\t<li>Content of file /sys/class/net//statistics/ multicast might have been out of date and might have displayed values lower than the real values.</li>\n\t<li>ERSPAN (Encapsulated Remote SPAN) protocol was available only when turning off Tx checksum offload.</li>\n\t<li>A udev script issue which caused non-mellanox devices to be renamed.</li>\n\t<li>Missing representor statistics when using ifconfig.</li>\n\t<li>Fixed wrong value of skb mark of received packets on representors.</li>\n\t<li>An issue which caused second port representors to be named as first port representors.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Changes and new features in HPE Mellanox RoCE driver&nbsp;version 5.3:</strong></p>\n\n<p><strong>For ConnectX-5 Adapters and above:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>CQE compression support for Rx multi-strides packets.</li>\n\t\t<li>Configuring QoS on a single QP or on a group of QPs.</li>\n\t\t<li>Encap/decap hardware offload of IPv4 traffic over MPLS-over-UDP. This can be used in networks with MPLS routers to achieve more efficient routing.</li>\n\t\t<li>Connection tracking rules on VFs to forward traffic from one VF to the other.</li>\n\t\t<li>Offloading sFlow sampling rules.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For ConnectX-5 Adapters and ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>A locking mechanism to enable parallel insertion of rules into the software steering using the mlx5dv_dr API. The parallel insertion improves the insertion rate and takes place when adding Rx and Tx rules via the FDB domain.</li>\n\t\t<li>Option to match mlx5dv_dr API on Geneve tunnel using a dynamic flex parser. The option header consists of class, type, length and data. The parser should be configured using devx command, after which a rule can be created to match on parser ID and data.</li>\n\t\t<li>Geneve tunneling offload, including matching on extension header.</li>\n\t\t<li>Parallel insertion and deletion of offloaded rules using multiple&nbsp;OVS threads.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>[Beta] Modify GTP-U TEID. This support requires flex parser&nbsp;configuration.</li>\n\t\t<li>[Beta] Improved performance of OVS Connection Tracking flows by&nbsp;enabling the merge of the multi-table flow matches and actions into one joint flow.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Dx Adapters and above:</strong></p>\n\n<p>Added support for the following features:</p>\n\n<ul>\n\t<li>Transmitted packet timestamping accuracy can be improved when using a timestamp generated at the port level instead of a timestamp generated upon CQE creation. Tx port time-stamping better reflects the actual time of a packet&#39;s transmission. This feature is disabled by default. The feature can be enabled or disabled using the following command. ethtool --set-priv-flags tx_port_ts on / off.</li>\n\t<li>Offloading tunnel rules when the source interface is VF (in addition to uplink) in the Hypervisor.</li>\n\t<li>Using Mirroring Offload with Connection Tracking.</li>\n\t<li>ASO flow meter using the mlx5dv_dr API, which allows for monitoring the packet rate for specific flows. When a packet hits a flow that is connected to a flow meter, the rate of packets through this meter is evaluated, and the packet is marked with a color copied into one of the C registers, according to the current rate compared to the reference rate.</li>\n\t<li>ASO first hit using the mlx5dv_dr API, which allows for tracking rule hits by packets. When a packet hits a rule with the ASO first hit action, a flag is set indicating this event, and the original value of the flag is copied to one of the C registers.</li>\n\t<li>mlx5dv_dr API support for matching on a new field &quot;gtpu_first_ext_dw_0&quot;. This field enables packet filtering based on the GTP-U first extension header (first dword only). To enable parsing of tunnel GTP-U extension header, run the following command. ./cloud_fw_reset.py FLEX_PARSER_PROFILE_ENABLE=3.</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Lx Adapters and above:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>IPsec full offload support for extended sequence number, replay protection window and lifetime packet limit.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;All HCA&#39;s:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>New query GID API that allows for querying a single GID entry by its port and GID index, or querying for all GID tables of a specific device. This API works over ioctl instead of sysfs, which accelerates the querying process.</li>\n\t\t<li>Performing multi-host firmware reset in order to upgrade the device firmware. Firmware reset loads the new firmware in case it was burnt on the flash and was pending activation, and reload.</li>\n\t\t<li>[Alpha] Firmware live patching in the driver. Live patching updates the firmware without the need to perform firmware reset. However, it can only be applied in scenarios where the difference between the current and new firmware versions are minor, which is decided upon by the firmware itself.</li>\n\t\t<li>devlink tool for performing firmware reset in order to upgrade the device firmware. Firmware reset loads the new firmware in case it was burnt on the flash and was pending activation, and reloads the current firmware image from the flash in case no new firmware was pending. For further information, please refer to the the devlink man page.</li>\n\t\t<li>A resiliency mechanism for the driver to manually poll the command event queue (EQ) in case of a command timeout. In case the resiliency mechanism finds unhandled event queue entry (EQE) due to a lost interrupt, the driver will handle it, after which the command interface returns to a healthy state.</li>\n\t\t<li>Setting a sniffer private flag is deprecated and no longer required. In order to capture offloaded/RoCE traffic, tcpdump can now be run on the RDMA device.</li>\n\t\t<li>Added per-port reporters to devlink health to manage per-port health activities. Users can now access the devlink port reporters by specifying the port index in addition to the device devlink name through the devlink health commands API. This update was first introduced in iproute2 v5.8. As part of this feature, mlx5e Tx and Rx reporters are now redefined as devlink port reporters. For examples, please see devlink-health manpage</li>\n\t\t<li>Optimized memory consumption of memory registration in huge page systems. As an example, in a 2MB huge page system, 600 MB would be saved for 100 GB memory registration.</li>\n\t\t<li>mlx5dv API to modify the configured UDP source port for RoCE packets of a given RC/UC QP when QP is in RTS state.</li>\n\t\t<li>Accelerating Tx datapath by saving PCI bandwidth and CPU utilization. The savings are achieved by aggregating multiple packets into a single WQE. The feature is driven by xmit_more for certain traffic types, such as UDP.</li>\n\t</ul>\n\t</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 5.3:</strong></p>\n\n<ul>\n\t<li>Clearing min_rate on all SR-IOV legacy VFs after setting min_rate to at least one of the VFs did not disable QoS min_rate.</li>\n\t<li>An empty /usr/src/mlnx-ofa_kernel/default is now no longer created.</li>\n\t<li>An issue where installing packages through a repository failed after generation of metapackages using --add-kernel-support. The failure occurred due to excessive and incorrect Obsolete headers in those metapackages.Enabled installation of mlnx-ofa_kernel package to /bin/python3 instead of / usr/bin/python3 on RHEL 8.x systems.</li>\n\t<li>All IPoIB offload packets were wrongly counted as rx_csum_complete. These packets are now identified as rx_csum_unnecessary packets.</li>\n\t<li>mlx5dv_dr_rule_destroy segmentation fault could happen in rare cases with multiple rules on the same matcher with a different number of actions. This could happen after reusing an already deleted rule memory with less actions.</li>\n\t<li>An issue of moving to SwitchDev mode after configuring DSCP (Differentiated Service Code Point).</li>\n\t<li>Global traffic class configuration did not take effect on DC QPs (Dynamically Connected Queue Pairs).</li>\n\t<li>ib_send_bw traffic frequently dropped to zero when RDMA CM was used, because of incorrect&nbsp;min_rnr_timer setting on the responder side. The min_rnr_timer setting is now aligned with the setting in non-RDMA CM cases.</li>\n\t<li>Traffic did not pass over VFs with VST QinQ feature is enabled.</li>\n\t<li>When traffic was sent over Geneve VLAN with Tx VLAN offload enabled and TSO (TCP Segmentation Offload)&nbsp;or Tx csum enabled, traffic could be dropped and not sent to the wire.</li>\n\t<li>An issue that caused the firmware to restart upon installing mlnxofed-dpdk-upstream-libs package manually.</li>\n\t<li>Bad utility paths in rdma-core &quot;dracut&quot; hooks on SLES systems, which used to result in the following errors when running &quot;dracut&quot; with the &quot;--add rdma&quot; option. dracut-install:\n\t<ul>\n\t\t<li>ERROR: installing &lsquo;/usr/libexec/mlx4-setup.sh&rsquo; dracut: /usr/lib/dracut/dracut-install -D /var/tmp/dracut.UdCOSJ/ initramfs /usr/libexec/mlx4-setup.sh dracut-install: ERROR: installing &lsquo;/usr/libexec/rdma-set-sriov-vf&rsquo; dracut: /usr/lib/dracut/dracut-install -D /var/tmp/dracut.UdCOSJ/ initramfs /usr/libexec/rdma-set-sriov-vf</li>\n\t</ul>\n\t</li>\n\t<li>Traffic class value was not updated in DCT when set via sysfs.</li>\n\t<li>A doorbell loss issue on AMD platforms with Secure Memory Encryption (SME).</li>\n\t<li>Registering memory using mlx5dv_devx_umem_reg while forking. Without this fix, applications which use fork() or similar syscalls while using a memory registered with umem_reg could hang due to incorrect physical page mapping. This fix requires setting the IBV_FORK_SAFE environment variable.</li>\n\t<li>When&nbsp;unbinding the device resulted in the following message being printed to the dmesg: &quot;failed to disable DC tracer&quot;</li>\n\t<li>Content of file /sys/class/net//statistics/ multicast might have been out of date and might have displayed values lower than the real values.</li>\n\t<li>ERSPAN (Encapsulated Remote SPAN) protocol was available only when turning off Tx checksum offload.</li>\n\t<li>A udev script issue which caused non-mellanox devices to be renamed.</li>\n\t<li>Missing representor statistics when using ifconfig.</li>\n\t<li>Fixed wrong value of skb mark of received packets on representors.</li>\n\t<li>An issue which caused second port representors to be named as first port representors.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG1800JEHMD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFL4CD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3830-304a45484d44","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: EG1800JEHMD"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 EG1800JEHMD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG1800JEHMD Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; None.</p>\n"}],"files":[{"bytes":"5545829","datemodified":"2021-07-23T08:29:03","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8a2c06af48-HPD6-9.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a2c06af48-HPD6-9.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a2c06af48-HPD6-9.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a2c06af48-HPD6-9.1/CP048079.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a2c06af48-HPD6-9.1/HCFL4CD6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a2c06af48-HPD6-9.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a2c06af48-HPD6-9.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a2c06af48-HPD6-9.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a2c06af48-HPD6-9.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048079.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048079.scexe"],"md5sum":"2957ed781570c986a3acbfeb59465af2","name":"firmware-hdd-8a2c06af48-HPD6-9.1.x86_64.rpm","release":"2021-07-23T08:16:09","revision":"0","sha1sum":"4c4ff7c197bf126b826a4e2515331c3118f188a3","size":"5MB","target_guids":["002340a5-4500-3147-3830-304a45484d44"],"type_of_change":"1","version":"HPD6"}],"id":{"product":"121d8116603e47a49293c085684f3fa1","version":"5c2157b1aea54b978fadca9a88c38935"},"installation":{"command":"CP040315.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EG1800JEHMD Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - EG1800JEHMDドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"EG1800JEHMD","target_guid":"002340a5-4500-3147-3830-304a45484d44","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T10:57:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG1800JEHMD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"tw","x_late":"<br type=\"_moz\"/>\n"},{"lang":"en","x_late":"<br type=\"_moz\" />\n"},{"lang":"ko","x_late":"<br type=\"_moz\"/>\n"},{"lang":"cn","x_late":"<br type=\"_moz\"/>\n"},{"lang":"ja","x_late":"<br type=\"_moz\"/>\n"}],"files":[{"bytes":"8708749","datemodified":"2021-05-17T20:17:35","file_list":["/CP047891.vmexe","/CP047891.vmexe64","/CP047891.vmfile","/CP047891.xml","/README.txt"],"md5sum":"b553e7afe5997da1f18e46752a3b02f5","name":"CP047891.zip","release":"2021-05-18T01:14:05","revision":"0","sha1sum":"52e6cfb62846c615f447917b2f5ca2d094418f0b","size":"8MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021","vib_list":[]}],"id":{"product":"48fa0a59576f43e996cb7cfa8674ff57","version":"34406048a6ec4bcba7151b885567642b"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component requires that the CRU driver be loaded before the component can run.</p>\n\n<p>The minimum CRU version for 5.1 is 5.0.3.9.<br />\nThe minimum CRU version for 5.5 is 5.5.4.1.<br />\nThe minimum CRU version for 6.0 is 6.0.8.<br />\nThe minimum CRU version for 6.5 is 6.5.8.<br />\nThe minimum CRU version for 6.7 is 6.7.10.<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>SPP Offline mode boots a special Linux OS environment, thus the Linux Components are used, not the VMware Components</li>\n</ul>\n\n<p><br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Download the appropriate SPP</li>\n\t<li>Add the component to the SPP</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run&nbsp; SUM</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps to complete the firmware update</li>\n\t<li>Refer to the SPP documentation for detailed instructions at:&nbsp; <a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Component ( CPxxxxxx.zip) in a temporary directory</li>\n\t<li>From the same directory, unzip the Component:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>To perform the standalone installation, execute the command:<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>Follow the directions given by the Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system for the firmware update to take effect</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、実行する前にCRUドライバーがロードされている必要があります。</p>\n\n<p>5.1の最小CRUバージョンは5.0.3.9です。<br />\n5.5の最小CRUバージョンは5.5.4.1です。<br />\n6.0の最小CRUバージョンは6.0.8です。<br />\n6.5の最小CRUバージョンは6.5.8です。<br />\n6.7の最小CRUバージョンは6.7.10です。<br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMwareコンポーネントではなく、Linuxコンポーネントが用いられます</li>\n</ul>\n\n<p><br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします</li>\n\t<li>SPPにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします</li>\n\t<li>SUMを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います</li>\n\t<li>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>コンポーネント (CPxxxxxx.zip)を一時ディレクトリに置きます</li>\n\t<li>同じディレクトリからコンポーネントをunzipします:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>スタンドアロンのインストールを行うために、次のコマンドを実行します：<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>コンポーネントの指示に従います</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n\t<li>システムを再起動し、ファームウェアのアップデートを有効にします</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware - HPE ProLiant XL170r/XL190r Gen9 (U14) Servers "},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor VMware - HPE ProLiant XL170r/XL190r Gen9 (U14)サーバー "}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"5","minor":"1","name":"VMware vSphere 5.1","platform":"vmware_esx_server","sr":"OEM"},{"major":"5","minor":"5","name":"VMware vSphere 5.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-06T15:45:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","latest_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358.  These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390.  These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"U14","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWFWK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRH620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-30475746574b","Version":"HPG6"},{"DeviceName":"MB002000GWFWL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRH620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-30475746574c","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB001000GWFWK and MB002000GWFWL Drives"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;&nbsp;MB001000GWFWK and MB002000GWFWL Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG5</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG5<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5896973","datemodified":"2021-07-23T10:31:42","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc4af697b-HPG6-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc4af697b-HPG6-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc4af697b-HPG6-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc4af697b-HPG6-5.1/CP048094.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc4af697b-HPG6-5.1/WRH620G6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc4af697b-HPG6-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc4af697b-HPG6-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc4af697b-HPG6-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc4af697b-HPG6-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048094.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048094.scexe"],"md5sum":"2d95c8896c120ef53ebccda7a6c9fc5d","name":"firmware-hdd-bfc4af697b-HPG6-5.1.x86_64.rpm","release":"2021-07-23T10:19:04","revision":"0","sha1sum":"8cb1f087b6f16dcbb486b45c78dbe9c3138eb13e","size":"5MB","target_guids":["4d2340a5-3042-3130-3030-30475746574b","4d2340a5-3042-3230-3030-30475746574c"],"type_of_change":"1","version":"HPG6"}],"id":{"product":"6114e7f77ac240e69cf280b518ec5e27","version":"5c7858b769d34fe8aed68430b80ef77f"},"installation":{"command":"CP040778.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB001000GWFWK and MB002000GWFWL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB001000GWFWKおよびMB002000GWFWLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB001000GWFWK","target_guid":"4d2340a5-3042-3130-3030-30475746574b","type":"sata"},{"id":"MB002000GWFWL","target_guid":"4d2340a5-3042-3230-3030-30475746574c","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T12:15:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB002000GWFWL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB001000GWFWK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000300JWCPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTND7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5743504b","Version":"HPD7"},{"DeviceName":"EH000600JWCPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTND7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5743504c","Version":"HPD7"},{"DeviceName":"EH000900JWCPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTND7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5743504e","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EH000300JWCPK, EH000600JWCPL, and EH000900JWCPN"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：EH000300JWCPK、EH000600JWCPL、およびEH000900JWCPN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - EH000300JWCPK, EH000600JWCPL&nbsp;and EH000900JWCPN Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"3781072","datemodified":"2021-07-24T05:56:12","file_list":["cp048510.xml","cpqsetup.exe","payload.json","setup.dll","SKESTND7.rel"],"md5sum":"68075c607b1fe59bf334047b6c57eedd","name":"cp048510.exe","release":"2021-07-24T05:48:08","revision":"0","sha1sum":"4d74837c7d11a145e39235d2e7ac07aaf6e55dcf","size":"3MB","target_guids":["452340a5-3048-3030-3330-304a5743504b","452340a5-3048-3030-3630-304a5743504c","452340a5-3048-3030-3930-304a5743504e"],"type_of_change":"1","version":"HPD7"}],"id":{"product":"3f2f70c223354bc6b59b77123faa8545","version":"ecb71206461a484da2e8a4cbd61d5859"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/jp/servers/spp_dl\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EH000300JWCPK, EH000600JWCPL and EH000900JWCPN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  EH000300JWCPK、EH000600JWCPL、およびEH000900JWCPNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EH000300JWCPK","target_guid":"452340a5-3048-3030-3330-304a5743504b","type":"sas"},{"id":"EH000600JWCPL","target_guid":"452340a5-3048-3030-3630-304a5743504c","type":"sas"},{"id":"EH000900JWCPN","target_guid":"452340a5-3048-3030-3930-304a5743504e","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T08:41:38","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH000300JWCPK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000900JWCPN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000600JWCPL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO0400KEFJB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304f-3430-304b45464a42","Version":"HPK4"},{"DeviceName":"VO1200KEFJC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314f-3230-304b45464a43","Version":"HPK4"},{"DeviceName":"VO2000KEFJD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-324f-3030-304b45464a44","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO0400KEFJB, VO1200KEFJC and VO2000KEFJD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for Linux (x64) - VO0400KEFJB, VO1200KEFJC&nbsp;and VO2000KEFJD Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4754432","datemodified":"2021-07-25T12:43:49","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-9a826ccd8a-HPK4-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-9a826ccd8a-HPK4-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-9a826ccd8a-HPK4-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9a826ccd8a-HPK4-6.1/4IFDHPK4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-9a826ccd8a-HPK4-6.1/CP045366.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-9a826ccd8a-HPK4-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9a826ccd8a-HPK4-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-9a826ccd8a-HPK4-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-9a826ccd8a-HPK4-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045366.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045366.scexe"],"md5sum":"fa10fe81bcfafe6eaeaa0efbc8474faf","name":"firmware-hdd-9a826ccd8a-HPK4-6.1.x86_64.rpm","release":"2021-07-25T12:31:04","revision":"0","sha1sum":"a60d89aa6a9d31262c72ba200403cc9e2b6277ab","size":"4MB","target_guids":["002340a5-5600-304f-3430-304b45464a42","002340a5-5600-314f-3230-304b45464a43","002340a5-5600-324f-3030-304b45464a44"],"type_of_change":"1","version":"HPK4"}],"id":{"product":"a35c5c84e8e149fe9fff61ed94a4a7ac","version":"985eead36b2143309c7841486491583a"},"installation":{"command":"CP040088.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - VO0400KEFJB, VO1200KEFJC and VO2000KEFJD Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - VO0400KEFJB、VO1200KEFJC、およびVO2000KEFJDドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VO0400KEFJB","target_guid":"002340a5-5600-304f-3430-304b45464a42","type":"nvme"},{"id":"VO1200KEFJC","target_guid":"002340a5-5600-314f-3230-304b45464a43","type":"nvme"},{"id":"VO2000KEFJD","target_guid":"002340a5-5600-324f-3030-304b45464a44","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T11:13:58","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO0400KEFJB","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO1200KEFJC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO2000KEFJD","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE QLogic NX2 10Gb and 20Gb Multifunction Gigabit Ethernet NICs running under Red Hat Enterprise Linux 7 x86_64."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7 x86_64で動作するHPE QLogic NX2 10Gbおよび20GbマルチファンクションGigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"6930209","datemodified":"2021-08-11T16:27:46","file_list":["./etc/depmod.d/netxtreme2.conf","./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/netxtreme2","./lib/modules/3.10.0-1160.el7.x86_64/extra/netxtreme2/bnx2.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/netxtreme2/bnx2fc.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/netxtreme2/bnx2i.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/netxtreme2/bnx2x.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/netxtreme2/cnic.ko","./usr/share/smartupdate/kmod-netxtreme2/component.xml"],"md5sum":"d5d435d85344519003f17093a9e960c9","name":"kmod-netxtreme2-7.14.80-6.rhel7u9.x86_64.rpm","release":"2021-08-11T15:59:10","revision":"0","sha1sum":"958da7e9d828aaa771f2202201e1746b0a41e0c5","size":"6MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec9fda3d1e"],"type_of_change":"0","version":"7.14.80-6"},{"bytes":"6928177","datemodified":"2021-08-11T16:23:05","file_list":["./etc/depmod.d/netxtreme2.conf","./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/netxtreme2","./lib/modules/3.10.0-1127.el7.x86_64/extra/netxtreme2/bnx2.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/netxtreme2/bnx2fc.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/netxtreme2/bnx2i.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/netxtreme2/bnx2x.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/netxtreme2/cnic.ko","./usr/share/smartupdate/kmod-netxtreme2/component.xml"],"md5sum":"3596590c48f5bdad9d859caafb25a8e4","name":"kmod-netxtreme2-7.14.80-6.rhel7u8.x86_64.rpm","release":"2021-08-11T15:59:10","revision":"0","sha1sum":"098f29457d732aab3fb0e9650ef596691abdaf24","size":"6MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec9fda3d1e"],"type_of_change":"0","version":"7.14.80-6"}],"id":{"product":"fd1884928c824890aec3a37db50b22e0","version":"51de2d7bd98b455ba8b17b0d7f781b01"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>Download README for any additional installation instructions.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 7 x86_64"},{"lang":"ja","x_late":"HPE QLogic NX2 10/20 GbEマルチファンクションドライバーfor Red Hat Enterprise Linux 7 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"16AD","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16ad159000ec","type":"pci","ven":"1077"},{"dev":"168E","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c339d","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c18d3","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c193a","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1930","type":"pci","ven":"14E4"},{"dev":"16A1","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a1159000ec","type":"pci","ven":"1077"},{"dev":"16A4","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a4159000ec","type":"pci","ven":"1077"},{"dev":"168E","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-168e15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1931","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c339d","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c18d3","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c193a","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1930","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1933","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1931","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1917","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"3382","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c3382","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c339d","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c193a","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1930","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1931","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16af15908148","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ae15908148","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product is particular for&nbsp;Red Hat Enterprise Linux 7 Update 8 patched kernel version 3.10.0-1127.10.1 or later.</p>\n","latest_fixes_x_late":"<p>This product corrects an issue where the patched kernel symbol changed on PTP (Precision Time Protocol) module.</p>\n\n<p>&nbsp;</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>This product now supports MDI(Medium Dependent Interface)/MDIX(Medium Dependent Interface Crossover) connection status to ethtool.</li>\n\t<li>This product now supports Timestamping the unicast Precision Time Protocol (PTP) packets.</li>\n</ul>\n","curr_fixes_x_late":"<p>This product addresses an issue where Virtual Local Area Networks(VLANs) resource accounting when linux driver creating 272 Virtual Local Area Networks(VLANs) on single Virtual Functions, then enable interface after closed.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-netxtreme2","sw_key_expectedpath":"software:rpm"},{"name":"kmod-netxtreme2","sw_key_expectedpath":"software:rpm"},{"name":"kmod-netxtreme2","sw_key_expectedpath":"software:rpm"},{"name":"kmod-netxtreme2","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EK000200GWEPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3030-3230-304757455044","Version":"HPG3"},{"DeviceName":"EK000400GWEPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3030-3430-304757455045","Version":"HPG3"},{"DeviceName":"EK000800GWEPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3030-3830-304757455046","Version":"HPG3"},{"DeviceName":"EK001600GWEPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3130-3630-304757455048","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EK000200GWEPD, EK000400GWEPE, EK000800GWEPF and EK001600GWEPH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EK000200GWEPD, EK000400GWEPE, EK000800GWEPF and EK001600GWEPH Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"15792953","datemodified":"2021-08-30T07:35:06","file_list":["/CP048295_BUILD_2.data","/CP048295.vmexe","/CP048295.vmexe64","/CP048295.vmfile","/CP048295_VMw.zip","/CP048295.xml","/payload.json","/CP048295_VMw.zip/index.xml","/CP048295_VMw.zip/vendor-index.xml","/CP048295_VMw.zip/metadata.zip","/CP048295_VMw.zip/vib20/CP048295/HPE_bootbank_CP048295_HPG3.2-7.0.0.15843807.vib","/CP048295_VMw.zip/metadata.zip/vendor-index.xml","/CP048295_VMw.zip/metadata.zip/vmware.xml","/CP048295_VMw.zip/metadata.zip/vibs/CP048295-8081142903580322682.xml","/CP048295_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048295_HPG3.2-7.0.0.15843807.xml"],"md5sum":"658cc0993069335683739eba69f344fe","name":"CP048295.zip","release":"2021-08-30T07:29:43","revision":"0","sha1sum":"74059d8adb7877f07eadb34cf036d76874eaeb09","size":"15MB","target_guids":["452340a5-304b-3030-3230-304757455044","452340a5-304b-3030-3430-304757455045","452340a5-304b-3030-3830-304757455046","452340a5-304b-3130-3630-304757455048"],"type_of_change":"1","version":"HPG3","vib_list":[{"name":"CP048295","version":"HPG3.2-7.0.0.15843807"}]}],"id":{"product":"31f6809eb59143388eb68360c8d0d7ac","version":"386d871897394fc28fa00e98012338fd"},"installation":{"command":"CP040680.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EK000200GWEPD, EK000400GWEPE, EK000800GWEPF and EK001600GWEPH Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EK000200GWEPD、EK000400GWEPE、EK000800GWEPF、およびEK001600GWEPHドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EK001600GWEPH","target_guid":"452340a5-304b-3130-3630-304757455048","type":"sata"},{"id":"EK000800GWEPF","target_guid":"452340a5-304b-3030-3830-304757455046","type":"sata"},{"id":"EK000400GWEPE","target_guid":"452340a5-304b-3030-3430-304757455045","type":"sata"},{"id":"EK000200GWEPD","target_guid":"452340a5-304b-3030-3230-304757455044","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-03T09:09:37","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EK000800GWEPF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"EK000400GWEPE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"EK000200GWEPD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"EK001600GWEPH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Apollo InfiniBand EDR 100Gb 2-port 840z Mezzanine FIO Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4-rel-12_28_2006-843400-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000EF","Version":"12.28.2006"},{"DeviceName":"HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_31_1014-872723-B21_Ax-UEFI-14.24.13-FlexBoot-3.6.403.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900257","Version":"16.31.1014"},{"DeviceName":"HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_31_1014-872725-B21_Ax_Bx-UEFI-14.24.13-FlexBoot-3.6.403.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900255","Version":"16.31.1014"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading firmware on HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter (HPE Part# 843400-B21), HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter (HPE Part# 872723-B21), HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter (HPE Part# 872725-B21) on Windows x86_64 platform."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>InfiniBand Card Type</td>\n\t\t\t<td>Firmware&nbsp;Version</td>\n\t\t\t<td>PSID</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter (843400-B21)</td>\n\t\t\t<td>12.28.2006</td>\n\t\t\t<td>\n\t\t\t<p>HPE2920111032</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter (872723-B21)</td>\n\t\t\t<td>16.31.1014</td>\n\t\t\t<td>HPE0000000017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter (872725-B21)</td>\n\t\t\t<td>16.31.1014</td>\n\t\t\t<td>HPE0000000008</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"18946192","datemodified":"2021-09-06T06:34:53","file_list":["cp047567.xml","cpqsetup.exe","fw-ConnectX4-rel-12_28_2006-843400-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","fw-ConnectX5-rel-16_31_1014-872723-B21_Ax-UEFI-14.24.13-FlexBoot-3.6.403.signed.bin","fw-ConnectX5-rel-16_31_1014-872725-B21_Ax_Bx-UEFI-14.24.13-FlexBoot-3.6.403.signed.bin","i2cbrdg.dll","installer.dll","libcmdif-1.dll","libgcc_s_seh-1.dll","libmlxfwops-1.dll","libmtcr-1.dll","libreg_access-1.dll","libstdc++-6.dll","libwinpthread-1.dll","libxml2.dll","mdevices.exe","mst64.sys","mstflint.exe","payload.json","perl526.dll","zlib1.dll"],"md5sum":"786db5dfe4018ec858e3ffa5c82ba682","name":"cp047567.exe","release":"2021-09-06T06:33:05","revision":"0","sha1sum":"87a172911ad84f118d97d5c82444218eb900b5e4","size":"18MB","target_guids":["a6b1a447-382a-5a4f-15B3-1013159000EF","a6b1a447-382a-5a4f-15B3-101715900257","a6b1a447-382a-5a4f-15B3-101715900255"],"type_of_change":"1","version":"1.0.0.8"}],"id":{"product":"d626b04e2b74450287a682c2c77ab027","version":"f1b769799f944c5fa027ae5484584781"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the Install button to proceed with the installation.</p>\n\n<p><strong>Note:&nbsp;</strong>In order to upgrade/downgrade CX5 network adapter firmware from 16.21.1xxx or 16.22.1xxx (and earlier) to 16.26.1xxx (and later), use 16.23.1xxx or 16.24.1xxx or 16.25.1xxx as intermediate firmware version</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (Windows x64) for HPE Mellanox IB only ConnectX4 and ConnectX5 devices on Windows x86_64 platform"}],"prerequisites":{"required_diskspace":{"size_kb":"27000"},"supported_devices":[{"dev":"1013","subdev":"00EF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000ef","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0257","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900257","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0255","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900255","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-16T06:34:22","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 12.28.1002:</strong></p>\n\n<p>843400-B21 (HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter)<br />\n<br />\n<strong>New Feature and Changes in Version 12.28.1002:</strong></p>\n\n<ul>\n\t<li>Increased the maximum XRQ number to 512.</li>\n</ul>\n\n<p><br />\n<strong>Firmware for the following devices are updated to 16.29.1016:</strong></p>\n\n<p>872723-B21 (HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter)<br />\n872725-B21 (HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter)<br />\n&nbsp;</p>\n\n<p><strong>New Feature and Changes in Version 16.29.1016:</strong></p>\n\n<p>Added support for following features:</p>\n\n<ul>\n\t<li>Changed the default value of DCQCN&#39;s (Data center- Quantized Congestion Notification) NP parameter min_time_between_cnps to 4 on all devices to support larger scalability of the cluster.</li>\n\t<li>An option to allow applications to build their own QoS tree over the NIC hierarchy by connecting QPs to responder/requestor Queue Groups.</li>\n\t<li>&quot;InfiniBand&quot; properties set to the Network Device Function Redfish object.</li>\n\t<li>HW support for Flow Metering to utilize Advanced Steering Operation (ASO).&nbsp;HW Flow Meter allows higher scale, more accuracy, and better performance compared to the FW Flow Metering.</li>\n\t<li>Trust level for VFs. Once the VF is trusted, it will get a set of trusted capabilities.</li>\n\t<li>2 new Mini CQE formats: Responder Mini CQE With Flow Tag Layout Responder Mini CQE With l3_l4_info Layout</li>\n\t<li>UCX can now enable AR by exposing Out-Of-Ordering bitmask per SL with &quot;ooo_per_sl&quot; field in the HCA_VPORT context. It can be also queried by running the QUERY_HCA_VPORT_CONTEXT&nbsp;command.</li>\n\t<li>Steering DP hash flow groups.</li>\n\t<li>A new counter per vPort that counts the number of packets that reached the Ethernet RQ but cannot fit into the WQE due to their large size. Additionally, we added the option to control if such packet will cause &ldquo;CQE with Error&rdquo; or &ldquo;CQE_MOCK&rdquo;.</li>\n\t<li>PCIe Rx modifications to prevent the adapter cards from disappearing from the system.</li>\n\t<li>ignore_flow_level is now enabled by the TRUST LEVEL access registry.&nbsp;</li>\n\t<li>cq_overrun counter. The counter represents the number of times CQs enter an error state due to overflow that occur when the device tries to post a CQE into a full CQ buffer.</li>\n\t<li>[Beta]&nbsp;Enabled the capability to allow Virtual Functions to send Pause Frames packets.</li>\n\t<li>Enabled 10/25GbE auto-sensing with 3rd party when using 10/25GbE optical cables.</li>\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Following issues have been fixed in firmware version 16.29.1016:</strong></p>\n\n<ul>\n\t<li>An issue that prevented&nbsp;VXLAN packets with svlan/ cvlan tag from being matched.</li>\n\t<li>An issue that caused the&nbsp;eth_wqe_too_small counter to count&nbsp;ODP (On-Demand Paging) page faults.</li>\n\t<li>When MKEY_BY_NAME was enabled by NVCONFIG and a large number of VFs are configured, VM restart (VF/PF FLR) will take longer than when MKEY_BY_NAME is disabled.</li>\n\t<li>&nbsp;Ani ssue that resulted in low performance after enabling the RoCE Accelerator capability. Note:&nbsp;The fix is available when all ports are set as Ethernet.&nbsp;</li>\n\t<li>On rare cases, a fatal error related to errors from the PCI transport layer might be reported during FLR.</li>\n\t<li>The chassis manager calculation for Multi-Host and Socket-Direct adapter cards to allow running NC-SI commands by the chassis manager BMC. Now the chassis manager is count as BMC with index 0, regardless of how many BMC there are.</li>\n\t<li>An issue that caused&nbsp;the device to go to down IRISC as one of the firmware semaphores could not be released&nbsp;when a speed change or port state change was triggered.&nbsp;</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 12.28.1002:</strong></p>\n\n<ul>\n\t<li>An issue that caused the DCR (DC Resources) to be destroyed before the retry option managed to work when the retry timeout is too big. in this case, the DCR&#39; time-to-live was increased, and the maximum retry timeout was decreased.</li>\n\t<li>Increased PHY power consumption limit to 1.5w.</li>\n\t<li>An issue that caused PortCounters.PortRcvErr / PPCNT.infiniband_counters.PortRcvErr not to report port icrc errors.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 12.28.2006:</strong></p>\n\n<p style=\"margin-left:40px\">843400-B21 (HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter)<br />\n&nbsp;</p>\n\n<ul>\n</ul>\n\n<p><strong>Firmware for the following devices are updated to 16.31.1014:</strong></p>\n\n<p style=\"margin-left:40px\">872723-B21 (HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter)<br />\n872725-B21 (HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter)</p>\n\n<p>&nbsp;</p>\n\n<p><strong>New features and changes in version 12.28.2006:</strong></p>\n\n<ul>\n\t<li>Increased the maximum XRQ number to 512.</li>\n</ul>\n\n<p><strong>New features and changes in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>NIC scheduling feature support has been disabled for non-privileged functions.</li>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Asymmetrical MSIX Configuration: This feature allows the device to be configured with a different number of MSIX vectors per physical PCI functions.To use this feature, please follow these steps:</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Clear NUM_PF_MSIX_VALID to disable global symmetrical MSIX configuration.</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Set PF_NUM_PF_MSIX_VALID to enable asymmetrical per Physical Function MSIX configuration.</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Configure PF_NUM_PF_MSIX per physical PCI function.</li>\n\t<li>RDMA partitioning and RDMA counters in IB mode.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.</li>\n\t<li>Enabled UID 0 to create resources with UMEM (User Memory).</li>\n\t<li>Receiving and sending native IB packets from/to the software (including all headers) via raw IBL2 QPs.</li>\n\t<li>RX RDMA NIC flow table on an IB port. Now the software can steer native IB packets to raw IB receive queues according to the DLID and &nbsp;the DQPN.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 12.28.2006:</strong></p>\n\n<ul>\n\t<li>An issue that caused the DCR (DC Resources) to be destroyed before the retry option managed to work when the retry timeout is too big. in this case, the DCR&#39; time-to-live was increased, and the maximum retry timeout was decreased.</li>\n\t<li>Increased PHY power consumption limit to 1.5w.</li>\n\t<li>An issue that caused PortCounters.PortRcvErr / PPCNT.infiniband_counters.PortRcvErr not to report port icrc errors.</li>\n</ul>\n\n<p><strong>The following issues have been fixed in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>An assert that was caused when trying to open 1024 functions on the device and the maximum number of functions was 1023.</li>\n\t<li>Occasional performance issues related to RC QPs using E2E-credits (not connected to SRQ and doing send/receive traffic) when the ROCE_ACCL tx_window was enabled.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>A rare issue that caused RX pipe to hang.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>An issue that caused the TX queue to get into an unresponsive state when the VF rate limiter was set.</li>\n</ul>\n\n<p style=\"margin-left:40px\"><strong>Additional Fixes included in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li style=\"margin-left: 40px;\">Disabled the CNP counter &ldquo;rp_cnp_ignored &quot; (triggered by OOS (out-of-sequence)) when all ports are IB.</li>\n\t<li style=\"margin-left: 40px;\">Fixed the TMP421 sensor temperature reporting.</li>\n\t<li style=\"margin-left: 40px;\">Fixed the rate select mechanism in QSFP modules.</li>\n\t<li style=\"margin-left: 40px;\">Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li style=\"margin-left: 40px;\">Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U27","value":"HPE ProLiant XL2x260w Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_IB_CX4_CX5","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox adapter cards."},{"lang":"ja","x_late":"このRPMには、サポートされているHPE Mellanoxアダプターカード用のHPEによるテストと承認済みのLinuxベースMellanox RoCE (RDMA over Converged Ethernet)ドライバーが含まれます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"2033484","datemodified":"2021-05-17T21:57:51","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/connectx.conf","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d/mlx4.driver","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/security/limits.d/30-libvma-limits.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/82-net-setup-link.rules","./etc/udev/rules.d/90-ib.rules","./sbin/connectx_port_config","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/ibdev2netdev","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_get_vfs.pl","./usr/bin/mlnx_perf","./usr/bin/mlnx_qcn","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/lib/python3.6/site-packages/__pycache__/dcbnetlink.cpython-36.opt-1.pyc","./usr/lib/python3.6/site-packages/__pycache__/dcbnetlink.cpython-36.pyc","./usr/lib/python3.6/site-packages/__pycache__/genetlink.cpython-36.opt-1.pyc","./usr/lib/python3.6/site-packages/__pycache__/genetlink.cpython-36.pyc","./usr/lib/python3.6/site-packages/__pycache__/netlink.cpython-36.opt-1.pyc","./usr/lib/python3.6/site-packages/__pycache__/netlink.cpython-36.pyc","./usr/lib/python3.6/site-packages/dcbnetlink.py","./usr/lib/python3.6/site-packages/genetlink.py","./usr/lib/python3.6/site-packages/netlink.py","./usr/lib/python3.6/site-packages/ofed_le_utils-1.0.3-py3.6.egg-info","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/vma.service","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.0","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.0.0","./usr/lib64/libmlx4-rdmav2.so","./usr/lib64/libmlx5-rdmav2.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.0.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.0.0","./usr/lib64/libvma-debug.so","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.0.2","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vma","./usr/sbin/vmad","./usr/share/doc/packages/ib2ib","./usr/share/doc/packages/ib2ib/README","./usr/share/doc/packages/libibumad","./usr/share/doc/packages/libibumad/AUTHORS","./usr/share/doc/packages/libibumad/COPYING","./usr/share/doc/packages/libibumad/ChangeLog","./usr/share/doc/packages/libibverbs","./usr/share/doc/packages/libibverbs/AUTHORS","./usr/share/doc/packages/libibverbs/COPYING","./usr/share/doc/packages/libibverbs/ChangeLog","./usr/share/doc/packages/libibverbs/README","./usr/share/doc/packages/libmlx4","./usr/share/doc/packages/libmlx4/AUTHORS","./usr/share/doc/packages/libmlx4/COPYING","./usr/share/doc/packages/libmlx4/README","./usr/share/doc/packages/libmlx5","./usr/share/doc/packages/libmlx5/AUTHORS","./usr/share/doc/packages/libmlx5/COPYING","./usr/share/doc/packages/libmlx5/README","./usr/share/doc/packages/librdmacm","./usr/share/doc/packages/librdmacm/AUTHORS","./usr/share/doc/packages/librdmacm/COPYING","./usr/share/doc/packages/librdmacm/README","./usr/share/doc/packages/libvma-9.0.2/README.txt","./usr/share/doc/packages/libvma-9.0.2/VMA_VERSION","./usr/share/doc/packages/libvma-9.0.2/journal.txt","./usr/share/man/man3/umad_addr_dump.3.gz","./usr/share/man/man3/umad_alloc.3.gz","./usr/share/man/man3/umad_attribute_str.3.gz","./usr/share/man/man3/umad_class_str.3.gz","./usr/share/man/man3/umad_close_port.3.gz","./usr/share/man/man3/umad_debug.3.gz","./usr/share/man/man3/umad_done.3.gz","./usr/share/man/man3/umad_dump.3.gz","./usr/share/man/man3/umad_free.3.gz","./usr/share/man/man3/umad_free_ca_namelist.3.gz","./usr/share/man/man3/umad_get_ca.3.gz","./usr/share/man/man3/umad_get_ca_namelist.3.gz","./usr/share/man/man3/umad_get_ca_portguids.3.gz","./usr/share/man/man3/umad_get_cas_names.3.gz","./usr/share/man/man3/umad_get_fd.3.gz","./usr/share/man/man3/umad_get_issm_path.3.gz","./usr/share/man/man3/umad_get_mad.3.gz","./usr/share/man/man3/umad_get_mad_addr.3.gz","./usr/share/man/man3/umad_get_pkey.3.gz","./usr/share/man/man3/umad_get_port.3.gz","./usr/share/man/man3/umad_init.3.gz","./usr/share/man/man3/umad_mad_status_str.3.gz","./usr/share/man/man3/umad_method_str.3.gz","./usr/share/man/man3/umad_open_port.3.gz","./usr/share/man/man3/umad_poll.3.gz","./usr/share/man/man3/umad_recv.3.gz","./usr/share/man/man3/umad_register.3.gz","./usr/share/man/man3/umad_register2.3.gz","./usr/share/man/man3/umad_register_oui.3.gz","./usr/share/man/man3/umad_release_ca.3.gz","./usr/share/man/man3/umad_release_port.3.gz","./usr/share/man/man3/umad_send.3.gz","./usr/share/man/man3/umad_set_addr.3.gz","./usr/share/man/man3/umad_set_addr_net.3.gz","./usr/share/man/man3/umad_set_grh.3.gz","./usr/share/man/man3/umad_set_grh_net.3.gz","./usr/share/man/man3/umad_set_pkey.3.gz","./usr/share/man/man3/umad_size.3.gz","./usr/share/man/man3/umad_status.3.gz","./usr/share/man/man3/umad_unregister.3.gz","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml"],"md5sum":"58ed35c24cc2c0b19aa0efc10e9c294b","name":"mlnx-ofa_kernel-4.9-OFED.4.9.3.1.6.1.sles15sp2.x86_64.rpm","release":"2021-05-17T20:36:15","revision":"0","sha1sum":"116a863ec1bf3387f92792df709ebd30895cdbee","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5"],"type_of_change":"1","version":"4.9"},{"bytes":"1998892","datemodified":"2021-05-17T22:00:42","file_list":["./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/compat","./lib/modules/5.3.18-22-default/updates/compat/mlx_compat.ko","./lib/modules/5.3.18-22-default/updates/drivers","./lib/modules/5.3.18-22-default/updates/drivers/infiniband","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/ib_cm.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/ib_core.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/ib_ucm.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/ib_umad.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/iw_cm.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/rdma_cm.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/cxgb3","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/cxgb3/iw_cxgb3.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/cxgb4","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/efa","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/efa/efa.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/hfi1","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/i40iw","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/mlx4","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/mlx5","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/mthca","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/mthca/ib_mthca.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/ocrdma","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/ocrdma/ocrdma.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/qedr","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/qib","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/qib/ib_qib.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/usnic","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/sw","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/sw/rdmavt","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/sw/rxe","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/sw/siw","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/sw/siw/siw.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/ipoib","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/iser","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/isert","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/opa_vnic","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/srp","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/srpt","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/5.3.18-22-default/updates/drivers/net","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlx4","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlx4/mlx4_core.ko","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlx4/mlx4_en.ko","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlx5","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlx5/fpga","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlx5/fpga/mlx5_fpga_tools.ko","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/5.3.18-22-default/updates/drivers/nvme","./lib/modules/5.3.18-22-default/updates/drivers/nvme/host","./lib/modules/5.3.18-22-default/updates/drivers/nvme/host/nvme-rdma.ko","./lib/modules/5.3.18-22-default/updates/drivers/nvme/target","./lib/modules/5.3.18-22-default/updates/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/5.3.18-22-default/updates/net","./lib/modules/5.3.18-22-default/updates/net/9p","./lib/modules/5.3.18-22-default/updates/net/9p/9pnet_rdma.ko","./lib/modules/5.3.18-22-default/updates/net/rds","./lib/modules/5.3.18-22-default/updates/net/rds/rds_rdma.ko","./lib/modules/5.3.18-22-default/updates/net/sunrpc","./lib/modules/5.3.18-22-default/updates/net/sunrpc/xprtrdma","./lib/modules/5.3.18-22-default/updates/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/5.3.18-22-default/updates/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/5.3.18-22-default/updates/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/mlnx-ofa_kernel-kmp-default/component.xml"],"md5sum":"e732fc329e7c984d77474a8902cb7ddc","name":"mlnx-ofa_kernel-kmp-default-4.9_k5.3.18_22-OFED.4.9.3.1.6.1.sles15sp2.x86_64.rpm","release":"2021-05-17T20:36:15","revision":"0","sha1sum":"22110a34ae0ec64707924719bce5a587c48f8292","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5"],"type_of_change":"1","version":"4.9"}],"id":{"product":"7af26f11b3bd4a2f99d0fd0dcc72a2db","version":"fe0e29915a4840188b46c950e84825d5"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"11.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPMs to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-4.9.&quot; RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using &nbsp;5.3.18-22-default&nbsp;kernel or any future errata:<br />\n<br />\n<strong># rpm -Uvh&nbsp;mlnx-ofa_kernel-4.9-OFED.4.9.3.1.6.1.sles15sp2.x86_64.rpm&nbsp;mlnx-ofa_kernel-kmp-default-4.9_k5.3.18_22-OFED.4.9.3.1.6.1.sles15sp2.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for SUSE LINUX Enterprise Server 15 SP2 (AMD64/EM64T)"},{"lang":"ja","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet)ドライバー for SUSE LINUX Enterprise Server 15 SP2 (AMD64/EM64T)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-17T16:52:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>The following changes and new features are added in version 4.9:</strong></p>\n\n<ul>\n\t<li><strong>For ConnectX-5 Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Option to dump configuration space via the devlink tool in order to improve debug capabilities.</li>\n\t<li>The conventional TX descriptor (WQE or Work Queue Element) describes a single packet for transmission. Added driver support for the HW feature of multi-packet TX WQEs in XDP transmit flows. With this, the HW becomes capable of working with a new and improved WQE layout that describes several packets. In effect, this feature saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>GENEVE encapsulation/decapsulation rules offload.</li>\n\t<li>Driver support for the hardware feature of multi-packet Tx to work with a new and improved WQE layout that describes several packets instead of a single packet for XDP transmission flows. This saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>Updating CT (Connection Tracking) rules using the software steering mechanism.</li>\n\t<li>Updating remote mirroring rules using the software steering mechanism.<br />\n\t&nbsp;</li>\n\t<li><strong>For ConnectX-4&nbsp;Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Exposed rx_prio[p]_discards discard counters per priority that count the number of received packets dropped due to lack of buffers on the physical port.</li>\n\t<li>Reporting TSO and CSUM offload capabilities for MPLS tagged traffic and, allowed the kernel stack to use these offloads.</li>\n\t<li>mlx5e Max Combined Channels Increased the driver&rsquo;s maximal combined channels value from 64 to 128 (however, note that OOB value will not cross 64). 128 is the upper bound. Lower maximal value can be seen on the host, depending on the number of cores and MSIX&#39;s configured by the firmware.</li>\n\t<li>Added the following RoCE accelerator counters:\n\t<ul>\n\t\t<li>roce_adp_retrans - counts the number of adaptive retransmissions for RoCE traffic.</li>\n\t\t<li>roce_adp_retrans_to - counts the number of times RoCE traffic reached timeout due to adaptive retransmission.</li>\n\t\t<li>roce_slow_restart - counts the number of times RoCE slow restart was used.</li>\n\t\t<li>roce_slow_restart_cnps - counts the number of times RoCE slow restart generated CNP packets roce_slow_restart_trans - counts the number of times RoCE slow restart changed state to slow restart.</li>\n\t</ul>\n\t</li>\n\t<li>User to register memory regions with a relaxed ordering access flag through experimental verbs. This can enhance performance, depending on architecture and scenario.<br />\n\t&nbsp;</li>\n\t<li><strong>For&nbsp;All HCA&#39;s</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Output ibdev2netdev tool output was changed such that the bonding device now points at the bond instead of the slave interface.</li>\n\t<li>Monitoring and recovering from errors that occur on the RX queue, such as cookie errors and timeout.</li>\n\t<li>Improved GSO (Generic Segmentation Offload) workload performance by decreasing doorbells usage to the minimum required.</li>\n\t<li>TX CQE (Completion Queue Element) compression. Saves on outgoing PCIe bandwidth by compressing CQEs together. Disabled by default. Configurable via private flags of ethtool.</li>\n\t<li>Firmware Versions Query via Devlink :Added the option to query for running and stored firmware versions using the devlink tool.</li>\n\t<li>Firmware Flash Update via Devlink :Added the option to update the firmware image in the flash using the devlink tool. Usage: devlink dev flash file .mfa2 For further information on how to perform this update, see &quot;Updating Firmware Using ethtool/devlink and .mfa2 File&quot; section in MFT User Manual.</li>\n\t<li>WQE (Work Queue Element) dump, triggered by an error on Rx/Tx reporters. In addition, some dumps (not triggered by an error) can be retrieved by the user via devlink health reporters.</li>\n\t<li>GENEVE tunneled hardware offloads of TSO, CSUM and RSS.</li>\n\t<li>TCP segmentation and checksum offload support for MPLS-tagged traffic.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 4.9:</strong></p>\n\n<ul>\n\t<li>An issue where injecting EEH (Extended Error Handlng) may cause extra Kernel prints, such as: &ldquo;EEH: Might be infinite loop in mlx5_core driver&rdquo; was fixed.</li>\n\t<li>RPM-based OSs with non-default kernels, using repositories after re-creating the installer (using --add-kernel-support) were&nbsp;resulting&nbsp;in improper installation of the drivers.</li>\n\t<li>A typo in perftest package where help messages wrongly displayed the conversion result between Gb/s and MB/s (20^2 instead of 2^20).</li>\n\t<li>When one of the LAG slaves went down, LAG deactivation failed, ultimately causing bandwidth degradation.</li>\n\t<li>The mlx5 driver maintains a subdirectory for every open eth port in /sys/kernel/debug/. For the default network namespace, the sub-directory name is the name of the interface, like &quot;eth8&quot;. The new convention for the network interfaces moved to the non-default network namespaces is the interfaces name followed by &quot;@&quot; and the port&#39;s PCI ID. For example: &quot;eth8@0000:af:00.3&quot;.</li>\n\t<li>&quot;openibd&quot; script load used to fail when esp6_offload module did not load successfully.</li>\n\t<li>Added dependency of package mpi-selectors on perl-Getopt-Long system package. On minimal installs of RPM-based OSs, installing mpi-selectros will also install the required system package perl-Getopt-Long.</li>\n\t<li>During certain rare scenarios, due to Rx page not being replenished, the same page fragment mistakenly became assigned to two different Rx descriptors.</li>\n\t<li>Driver load issue existed with Errata-kernel on SLES15 SP1.</li>\n\t<li>An issue in the Hairpin feature which prevented adding hairpin flows using TC tool was fixed.</li>\n\t<li>WQ (Work Queue)&nbsp;queue flushing was not handled properly in the event of EEH.</li>\n\t<li>A rare kernel crash scenario when exiting an application that uses RMPP mads intensively.</li>\n\t<li>A possible kernel crash scenario when AER/slot reset in done in parallel to user space commands execution.</li>\n\t<li>Added missing ECN (Explicit Congestion Notification) configuration under sysfs for PFs in SwitchDev mode.</li>\n\t<li>When firmware response time to commands became very long, some commands failed upon timeout. The driver may have then triggered a timeout completion on the wrong entry, leading to a NULL pointer call trace.</li>\n\t<li>Added driver support for kernels with the old XDP_REDIRECT infrastructure that uses the following NetDev operations: .ndo_xdp_flush and .ndo_xdp_xmit.</li>\n\t<li>Usage of --excludedocs Open MPI RPM option resulted in the removal of non-documentation related files.</li>\n\t<li>Disabled automated loading of some modules through udev triggers to preserve the startup process of previous MLNX_OFED versions.</li>\n\t<li>Reference count (refcount) for RDMA connection ID (cm_id) was not incremented in rdma_resolve_addr() function, resulting in a cm_id use-after-free access. A fix was applied to increment the cm_id refcount</li>\n\t<li>A race condition which caused kernel panic when moving two ports to SwitchDev mode at the same time.</li>\n\t<li>Allowed accessing sysfs hardware counters in SwitchDev mode</li>\n\t<li>Function smp_processor_id() is called in the RX page recycle flow to determine the core to run on. This is intended to run in NAPI context. However, due to a bug in backporting, the RX page recycle was mistakenly called also in the RQ close flow when not needed.</li>\n\t<li>Port link state was automatically changed (without admin state involvement) to &quot;UP&quot; after reboot.</li>\n\t<li>ConnectX-3 adapter cards froze when running over SLES 11 OS.</li>\n\t<li>RDMA CM (Remote Direct Memory Access Communation Manager) connection failed when port space was small.</li>\n\t<li>Traffic mirroring with OVS (Open VSwitch)offload and non-offload over VxLAN interface is now supported. Note: For kernel 4.9, make sure to use a dedicated OVS version.</li>\n\t<li>When working with VF LAG while the bond device is in active-active mode, running fwreset would result in unequal traffic on both PFs, and PFs would not reach line rate.</li>\n\t<li>When bond was created over VF (Virtuaal Function)&nbsp;netdevices in SwitchDev mode, the VF netdevice would be treated as representor netdevice. This caused the mlx5_core driver to crash in case it received netdevice events related to bond device.</li>\n\t<li>An issue where following a bad affinity occurrence in VF LAG mode, traffic was sent after the port went up/down in the switch.</li>\n\t<li>Added support for VLAN (Virtual Local Area Network)&nbsp;header rewrite on CentOS 7.2 OS.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>The following changes and new features are added in version 4.9:</strong></p>\n\n<ul>\n\t<li><strong>For ConnectX-5 Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Option to dump configuration space via the devlink tool in order to improve debug capabilities.</li>\n\t<li>The conventional TX descriptor (WQE or Work Queue Element) describes a single packet for transmission. Added driver support for the HW feature of multi-packet TX WQEs in XDP transmit flows. With this, the HW becomes capable of working with a new and improved WQE layout that describes several packets. In effect, this feature saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>GENEVE encapsulation/decapsulation rules offload.</li>\n\t<li>Driver support for the hardware feature of multi-packet Tx to work with a new and improved WQE layout that describes several packets instead of a single packet for XDP transmission flows. This saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>Updating CT (Connection Tracking) rules using the software steering mechanism.</li>\n\t<li>Updating remote mirroring rules using the software steering mechanism.<br />\n\t&nbsp;</li>\n\t<li><strong>For ConnectX-4&nbsp;Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Exposed rx_prio[p]_discards discard counters per priority that count the number of received packets dropped due to lack of buffers on the physical port.</li>\n\t<li>Reporting TSO and CSUM offload capabilities for MPLS tagged traffic and, allowed the kernel stack to use these offloads.</li>\n\t<li>mlx5e Max Combined Channels Increased the driver&rsquo;s maximal combined channels value from 64 to 128 (however, note that OOB value will not cross 64). 128 is the upper bound. Lower maximal value can be seen on the host, depending on the number of cores and MSIX&#39;s configured by the firmware.</li>\n\t<li>Added the following RoCE accelerator counters:\n\t<ul>\n\t\t<li>roce_adp_retrans - counts the number of adaptive retransmissions for RoCE traffic.</li>\n\t\t<li>roce_adp_retrans_to - counts the number of times RoCE traffic reached timeout due to adaptive retransmission.</li>\n\t\t<li>roce_slow_restart - counts the number of times RoCE slow restart was used.</li>\n\t\t<li>roce_slow_restart_cnps - counts the number of times RoCE slow restart generated CNP packets roce_slow_restart_trans - counts the number of times RoCE slow restart changed state to slow restart.</li>\n\t</ul>\n\t</li>\n\t<li>User to register memory regions with a relaxed ordering access flag through experimental verbs. This can enhance performance, depending on architecture and scenario.<br />\n\t&nbsp;</li>\n\t<li><strong>For&nbsp;All HCA&#39;s</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Output ibdev2netdev tool output was changed such that the bonding device now points at the bond instead of the slave interface.</li>\n\t<li>Monitoring and recovering from errors that occur on the RX queue, such as cookie errors and timeout.</li>\n\t<li>Improved GSO (Generic Segmentation Offload) workload performance by decreasing doorbells usage to the minimum required.</li>\n\t<li>TX CQE (Completion Queue Element) compression. Saves on outgoing PCIe bandwidth by compressing CQEs together. Disabled by default. Configurable via private flags of ethtool.</li>\n\t<li>Firmware Versions Query via Devlink :Added the option to query for running and stored firmware versions using the devlink tool.</li>\n\t<li>Firmware Flash Update via Devlink :Added the option to update the firmware image in the flash using the devlink tool. Usage: devlink dev flash file .mfa2 For further information on how to perform this update, see &quot;Updating Firmware Using ethtool/devlink and .mfa2 File&quot; section in MFT User Manual.</li>\n\t<li>WQE (Work Queue Element) dump, triggered by an error on Rx/Tx reporters. In addition, some dumps (not triggered by an error) can be retrieved by the user via devlink health reporters.</li>\n\t<li>GENEVE tunneled hardware offloads of TSO, CSUM and RSS.</li>\n\t<li>TCP segmentation and checksum offload support for MPLS-tagged traffic.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 4.9:</strong></p>\n\n<ul>\n\t<li>An issue where injecting EEH (Extended Error Handlng) may cause extra Kernel prints, such as: &ldquo;EEH: Might be infinite loop in mlx5_core driver&rdquo; was fixed.</li>\n\t<li>RPM-based OSs with non-default kernels, using repositories after re-creating the installer (using --add-kernel-support) were&nbsp;resulting&nbsp;in improper installation of the drivers.</li>\n\t<li>A typo in perftest package where help messages wrongly displayed the conversion result between Gb/s and MB/s (20^2 instead of 2^20).</li>\n\t<li>When one of the LAG slaves went down, LAG deactivation failed, ultimately causing bandwidth degradation.</li>\n\t<li>The mlx5 driver maintains a subdirectory for every open eth port in /sys/kernel/debug/. For the default network namespace, the sub-directory name is the name of the interface, like &quot;eth8&quot;. The new convention for the network interfaces moved to the non-default network namespaces is the interfaces name followed by &quot;@&quot; and the port&#39;s PCI ID. For example: &quot;eth8@0000:af:00.3&quot;.</li>\n\t<li>&quot;openibd&quot; script load used to fail when esp6_offload module did not load successfully.</li>\n\t<li>Added dependency of package mpi-selectors on perl-Getopt-Long system package. On minimal installs of RPM-based OSs, installing mpi-selectros will also install the required system package perl-Getopt-Long.</li>\n\t<li>During certain rare scenarios, due to Rx page not being replenished, the same page fragment mistakenly became assigned to two different Rx descriptors.</li>\n\t<li>Driver load issue existed with Errata-kernel on SLES15 SP1.</li>\n\t<li>An issue in the Hairpin feature which prevented adding hairpin flows using TC tool was fixed.</li>\n\t<li>WQ (Work Queue)&nbsp;queue flushing was not handled properly in the event of EEH.</li>\n\t<li>A rare kernel crash scenario when exiting an application that uses RMPP mads intensively.</li>\n\t<li>A possible kernel crash scenario when AER/slot reset in done in parallel to user space commands execution.</li>\n\t<li>Added missing ECN (Explicit Congestion Notification) configuration under sysfs for PFs in SwitchDev mode.</li>\n\t<li>When firmware response time to commands became very long, some commands failed upon timeout. The driver may have then triggered a timeout completion on the wrong entry, leading to a NULL pointer call trace.</li>\n\t<li>Added driver support for kernels with the old XDP_REDIRECT infrastructure that uses the following NetDev operations: .ndo_xdp_flush and .ndo_xdp_xmit.</li>\n\t<li>Usage of --excludedocs Open MPI RPM option resulted in the removal of non-documentation related files.</li>\n\t<li>Disabled automated loading of some modules through udev triggers to preserve the startup process of previous MLNX_OFED versions.</li>\n\t<li>Reference count (refcount) for RDMA connection ID (cm_id) was not incremented in rdma_resolve_addr() function, resulting in a cm_id use-after-free access. A fix was applied to increment the cm_id refcount</li>\n\t<li>A race condition which caused kernel panic when moving two ports to SwitchDev mode at the same time.</li>\n\t<li>Allowed accessing sysfs hardware counters in SwitchDev mode</li>\n\t<li>Function smp_processor_id() is called in the RX page recycle flow to determine the core to run on. This is intended to run in NAPI context. However, due to a bug in backporting, the RX page recycle was mistakenly called also in the RQ close flow when not needed.</li>\n\t<li>Port link state was automatically changed (without admin state involvement) to &quot;UP&quot; after reboot.</li>\n\t<li>ConnectX-3 adapter cards froze when running over SLES 11 OS.</li>\n\t<li>RDMA CM (Remote Direct Memory Access Communation Manager) connection failed when port space was small.</li>\n\t<li>Traffic mirroring with OVS (Open VSwitch)offload and non-offload over VxLAN interface is now supported. Note: For kernel 4.9, make sure to use a dedicated OVS version.</li>\n\t<li>When working with VF LAG while the bond device is in active-active mode, running fwreset would result in unequal traffic on both PFs, and PFs would not reach line rate.</li>\n\t<li>When bond was created over VF (Virtuaal Function)&nbsp;netdevices in SwitchDev mode, the VF netdevice would be treated as representor netdevice. This caused the mlx5_core driver to crash in case it received netdevice events related to bond device.</li>\n\t<li>An issue where following a bad affinity occurrence in VF LAG mode, traffic was sent after the port went up/down in the switch.</li>\n\t<li>Added support for VLAN (Virtual Local Area Network)&nbsp;header rewrite on CentOS 7.2 OS.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK0400JEABD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM2RD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3430-304a45414244","Version":"HPD4"},{"DeviceName":"VK0800JEABE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM2RD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3830-304a45414245","Version":"HPD4"},{"DeviceName":"VO1600JEABF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM2RD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314f-3630-304a45414246","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK0400JEABD, VK0800JEABE and VO1600JEABF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online HDD/SSD Flash Component for Windows (x64) - VK0400JEABD, VK0800JEABE, and VO1600JEABF Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD3</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>If Power On Hours exceeds 70,000hrs, PM2R will report Hardware error (04/4C/A8) after the next Power Cycle and will not accept read/write commands. This fix will update storage location reporting when the maximum number of registrations in the Work Load Log read process reaches 70,000; the last registered 70,000th storage location will be modified to be read as the next (70,001st) storage location.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111296en_us</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"2881312","datemodified":"2021-08-31T14:06:00","file_list":["cp049412.xml","cpqsetup.exe","payload.json","setup.dll","TAPM2RD4.rel"],"md5sum":"ed0ffd21acd9adbde7b0fcc93110a404","name":"cp049412.exe","release":"2021-08-31T13:58:16","revision":"0","sha1sum":"207698f78d5128bd8fb680995bb0a56628601af3","size":"2MB","target_guids":["002340a5-5600-304b-3430-304a45414244","002340a5-5600-304b-3830-304a45414245","002340a5-5600-314f-3630-304a45414246"],"type_of_change":"2","version":"HPD4"}],"id":{"product":"d2a88686878e43e6b0ba883edf80c3c8","version":"694f1729bd1942ac8e61deb281cf4b99"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK0400JEABD, VK0800JEABE, and VO1600JEABF Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows（x64）- VK0400JEABD、VK0800JEABE、およびVO1600JEABFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VO1600JEABF","target_guid":"002340a5-5600-314f-3630-304a45414246","type":"sas"},{"id":"VK0400JEABD","target_guid":"002340a5-5600-304b-3430-304a45414244","type":"sas"},{"id":"VK0800JEABE","target_guid":"002340a5-5600-304b-3830-304a45414245","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-30T10:35:19","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>If Power On Hours exceeds 70,000hrs, PM2R will report Hardware error (04/4C/A8) after the next Power Cycle and will not accept read/write commands. This fix will update storage location reporting when the maximum number of registrations in the Work Load Log read process reaches 70,000; the last registered 70,000th storage location will be modified to be read as the next (70,001st) storage location.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111296en_us</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>If Power On Hours exceeds 70,000hrs, PM2R will report Hardware error (04/4C/A8) after the next Power Cycle and will not accept read/write commands. This fix will update storage location reporting when the maximum number of registrations in the Work Load Log read process reaches 70,000; the last registered 70,000th storage location will be modified to be read as the next (70,001st) storage location.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111296en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK0400JEABD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO1600JEABF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VK0800JEABE","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 546FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-full-rel-2_42_5044-779799-B21_Ax-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C8020","Version":"2.42.5044"},{"DeviceName":"HPE Ethernet 10Gb 2-port 546SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-full-rel-2_42_5044-779793-B21_0A-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C801F","Version":"2.42.5044"},{"DeviceName":"HPE Ethernet 100Gb 1-port 842QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_31_1014-874253-B21_Ax-UEFI-14.24.13-FlexBoot-3.6.403.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900246","Version":"16.31.1014"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640 FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_31_1200-817749-B21_Ax-UEFI-14.24.13-FlexBoot-3.6.403.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D3","Version":"14.31.1200"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_31_1200-817753-B21_Ax-UEFI-14.24.13-FlexBoot-3.6.403.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D4","Version":"14.31.1200"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Mellanox Ethernet only adapter firmware on ESXi 7.0."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 546SFP+ Adapter (779793-B21)</td>\n\t\t\t<td>2.42.5044</td>\n\t\t\t<td>HP_1200111023</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 546FLR-SFP+ Adapter (779799-B21)</td>\n\t\t\t<td>2.42.5044</td>\n\t\t\t<td>HP_2240110004</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)</td>\n\t\t\t<td>14.31.1200</td>\n\t\t\t<td>HP_2690110034</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</td>\n\t\t\t<td>14.31.1200</td>\n\t\t\t<td>HP_2420110034</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter&nbsp;(874253-B21)</td>\n\t\t\t<td>16.31.1014</td>\n\t\t\t<td>HPE0000000014</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"29246087","datemodified":"2021-09-14T03:17:30","file_list":["/CP046592.vmexe64","/CP046592.vmfile","/CP046592.xml","/CP046592_VMw.zip","/payload.json","/README.txt","/CP046592_VMw.zip/index.xml","/CP046592_VMw.zip/vendor-index.xml","/CP046592_VMw.zip/metadata.zip","/CP046592_VMw.zip/vib20/CP046592/HPE_bootbank_CP046592_1.0.0-7.0.0.15525992.vib","/CP046592_VMw.zip/metadata.zip/vendor-index.xml","/CP046592_VMw.zip/metadata.zip/vmware.xml","/CP046592_VMw.zip/metadata.zip/vibs/CP046592-45410901065416082.xml","/CP046592_VMw.zip/metadata.zip/bulletins/Smart-Component-CP046592_1.0.0-7.0.0.15525992.xml"],"md5sum":"52deee4c93aff65f1821977ec5f05231","name":"CP046592.zip","release":"2021-09-14T12:12:23","revision":"0","sha1sum":"3bbafae9f0eced1dfd48eb101e713b32c8675968","size":"27MB","target_guids":["a6b1a447-382a-5a4f-15B3-1007103C8020","a6b1a447-382a-5a4f-15B3-1007103C801F","a6b1a447-382a-5a4f-15B3-101715900246","a6b1a447-382a-5a4f-15B3-1015159000D3","a6b1a447-382a-5a4f-15B3-1015159000D4"],"type_of_change":"1","version":"1.0.2","vib_list":[{"name":"CP046592","version":"1.0.0-7.0.0.15525992"}]}],"id":{"product":"4a88cfeb4a984c96a13ab1090bcaab71","version":"c81a18f23f3845e990f4ac638f027c82"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Offline: &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p>\n\n<p>Remote Online, if the component is supported by SUM but is not yet part of an SPP:<br />\n&nbsp; &nbsp; Download the appropriate SPP<br />\n&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />\n&nbsp; &nbsp; Run SUM<br />\n&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />\n&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />\n&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />\n&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />\n&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />\n&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at: <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p>\n\n<p>Note: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p>\n\n<p>To use HPE Insight Control for vCenter: &nbsp;<br />\n&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />\n&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p>\n\n<p>To update firmware from VMware ESXi operating system on target server: &nbsp;<br />\n&nbsp; &nbsp; Enable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Login as root. (You must be root in order to apply the update) &nbsp;<br />\n&nbsp; &nbsp; Place the Smart Component in a temporary directory<br />\n&nbsp; &nbsp; Check if the nmst module is loaded already: vmkload_mod -l | grep nmst<br />\n&nbsp; &nbsp; If module is not loaded, use the command to load the module: vmkload_mod nmst<br />\n&nbsp; &nbsp; From the same directory, execute the Smart Component. For example: unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe<br />\n&nbsp; &nbsp; Follow the directions given by the Smart Component.<br />\n&nbsp; &nbsp; Logout.<br />\n&nbsp; &nbsp; Disable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Reboot your system, if required, for the firmware update to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (ESXi 7.0) for HPE Mellanox Ethernet only adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-18T07:53:26","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5044 :</strong></p>\n\n<p>&nbsp; &nbsp;779799-B21 (HPE Ethernet 10G 2-port 546FLR-SFP+ Adapter)<br />\n&nbsp; &nbsp;779793-B21 (HPE Ethernet 10G 2-port 546SFP+ Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.31.1200:</strong></p>\n\n<p>&nbsp; &nbsp;817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</p>\n\n<p>&nbsp;&nbsp;&nbsp;817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following device is updated to 16.29.1016:</strong></p>\n\n<p>&nbsp; &nbsp;874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</p>\n\n<p><strong>New Features and Changes included in version 16.31.1200:</strong></p>\n\n<ul>\n\t<li>Added a new NVconfig per Port for a specific Finisar module. This new NVconfig&nbsp;sets the port to work in AN mode and sets the module to No Data Management Engine (DME). This change&nbsp;does not affect the speed logic, only the forward error correction (FEC) logic (FEC override). <strong>Note:</strong>&nbsp;If the port does not&nbsp;come up, switch to Force mode.&nbsp;</li>\n</ul>\n\n<p><strong>New features and changes included &nbsp;in version 16.29.1016:</strong></p>\n\n<ul>\n\t<li>An option to allow applications to build their own QoS tree over the NIC hierarchy by connecting QPs to responder/requestor Queue Groups.</li>\n\t<li>&quot;InfiniBand&quot; properties set to the Network Device Function Redfish object.</li>\n\t<li>HW support for Flow Metering to utilize Advanced Steering Operation (ASO).&nbsp;HW Flow Meter allows higher scale, more accuracy, and better performance compare to the FW Flow Metering.</li>\n\t<li>Trust level for VFs. Once the VF is trusted, it will get a set of trusted capabilities.</li>\n\t<li>2 new Mini CQE formats: Responder Mini CQE With Flow Tag Layout Responder Mini CQE With l3_l4_info Layout</li>\n\t<li>UCX can now enable AR by exposing Out-Of-Ordering bitmask per SL with &quot;ooo_per_sl&quot; field in the HCA_VPORT context. It can be also queried by running the QUERY_HCA_VPORT_CONTEXT&nbsp;command.</li>\n\t<li>Steering DP hash flow groups.</li>\n\t<li>A new counter per vPort that counts the number of packets that reached the Ethernet RQ but cannot fit into the WQE due to their large size. Additionally, we added the option to control if such packet will cause &ldquo;CQE with Error&rdquo; or &ldquo;CQE_MOCK&rdquo;.</li>\n\t<li>PCIe Rx modifications to prevent the adapter cards from disappearing from the system.</li>\n\t<li>ignore_flow_level is now enabled by the TRUST LEVEL access registry.&nbsp;</li>\n\t<li>cq_overrun counter. The counter represents the number of times CQs enter an error state due to overflow that occur when the device tries to post a CQE into a full CQ buffer.</li>\n\t<li>[Beta]&nbsp;Enabled the capability to allow Virtual Functions to send Pause Frames packets.</li>\n\t<li>Enabled 10/25GbE auto-sensing with 3rd party when using 10/25GbE optical cables.</li>\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Fixes&nbsp;included in&nbsp; firmware version 2.42.5044 :</strong></p>\n\n<ul>\n\t<li>An issue that prevented the firmware from detecting a link_down event thus preventing the IB bond interface from going to a failover mode.</li>\n</ul>\n\n<p><strong>Fixes included&nbsp;in firmware version 14.29.1016:</strong></p>\n\n<ul>\n\t<li>Changed the default value of DCQCN&#39;s (Data center- Quantized Congestion Notification) &nbsp;NP parameter min_time_between_cnps to 4 on all devices to support larger scalability of cluster.</li>\n\t<li>An issue that caused&nbsp;packets to drop due to header size issues and/or failing checks. The issue was caused due to a Linux issue that caused&nbsp;VFs to set the wrong header size value in wqe_inline_header_mode input.</li>\n\t<li>When MKEY_BY_NAME was&nbsp;enabled by NVCONFIG and a large number of VFs were configured, VM restart (VF/PF FLR) will take longer than when MKEY_BY_NAME is disabled.</li>\n\t<li>On rare cases, a fatal error related to errors from the PCI transport layer might be reported during FLR.</li>\n\t<li>&nbsp;An issue that caused&nbsp;the device to go to dead IRISC as one of the firmware semaphores could not be released&nbsp;when a speed change or port state change was triggered.&nbsp;</li>\n</ul>\n\n<p><strong>No fixes are included in firmware version 14.31.1200.</strong></p>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5044 :</strong></p>\n\n<p>&nbsp; &nbsp;779799-B21 (HPE Ethernet 10G 2-port 546FLR-SFP+ Adapter)<br />\n&nbsp; &nbsp;779793-B21 (HPE Ethernet 10G 2-port 546SFP+ Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.31.1200:</strong></p>\n\n<p>&nbsp; &nbsp;817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.31.1200:</strong><br />\n&nbsp; &nbsp;817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following device is updated to 16.31.1014:</strong></p>\n\n<p>&nbsp; &nbsp;874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</p>\n\n<p><br />\n<strong>New features and changes in version 14.31.1200:</strong></p>\n\n<ul>\n\t<li>NVconfig per Port for a Specific Finisar Module: Added a new NVconfig per Port for a specific Finisar module. This new NVconfig sets the port to work in AN mode and sets the module to No DME. This change does not affect the speed logic, only the FEC logic (FEC override).<br />\n\t<strong>Note:</strong>&nbsp;If the port does not go up, switch to Force mode.&nbsp;</li>\n</ul>\n\n<p><strong>New features and changes in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>NIC scheduling feature support has been disabled for non-privileged functions.</li>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>Added support for Enabling/Disabling NIC and RDMA (port/partition) via the UEFI HII system settings.<br />\n\t<strong>Note:</strong>&nbsp;Values set in this option only take effect when is Ethernet mode.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Asymmetrical MSIX Configuration:&nbsp;This feature allows the device to be configured with a different number of MSIX<br />\n\tvectors per physical PCI functions.<br />\n\tTo use this feature, please follow these steps:\n\t<ul>\n\t\t<li>​​​​Clear NUM_PF_MSIX_VALID to disable global symmetrical MSIX configuration.</li>\n\t\t<li>Set PF_NUM_PF_MSIX_VALID to enable asymmetrical per Physical Function MSIX configuration.</li>\n\t\t<li>Configure PF_NUM_PF_MSIX per physical PCI function.</li>\n\t</ul>\n\t</li>\n\t<li>Support for RDMA partitioning and RDMA counters in IB mode.</li>\n\t<li>A new bit (&quot;data_in_order&quot;) was added to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.<br />\n\tPages are returned by the driver to the kernel without issuing the MANAGE_PAGES commands to the firmare.</li>\n\t<li>Enabled UID 0 to create resources with UMEM (User Memory).</li>\n\t<li>Receiving and sending native IB packets from/to the software (including all headers) via raw IBL2 QPs.</li>\n\t<li>RX RDMA NIC flow table on an IB port. Now the software can steer native IB packets to raw IB receive queues according to the DLID and<br />\n\tthe DQPN.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Fixes&nbsp;included in&nbsp; firmware version 2.42.5044 :</strong></p>\n\n<ul>\n\t<li>An issue that prevented the firmware from detecting a link_down event thus preventing the IB bond interface from going to a failover mode.</li>\n</ul>\n\n<p><strong>The following issues have been fixed in version 14.31.1200:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n</ul>\n\n<p style=\"margin-left:40px\"><strong>Additional Fixes included in version 14.31.1200:</strong></p>\n\n<ul>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n</ul>\n\n<p><strong>The following issues have been fixed in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>An assert that was caused when trying to open 1024 functions on the device and the maximum number of functions was 1023.</li>\n\t<li>Occasional performance issues related to RC QPs using E2E-credits (not connected to SRQ and doing send/receive traffic) when the ROCE_ACCL tx_window was enabled.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>A rare issue that caused RX pipe to hang.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>An issue that caused the TX queue to get into an unresponsive state when the VF rate limiter was set.</li>\n</ul>\n\n<p style=\"margin-left:40px\"><strong>Additional Fixes included in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>Disabled the CNP counter &ldquo;rp_cnp_ignored &quot; (triggered by OOS (out-of-sequence)) when all ports are IB.</li>\n\t<li>Fixed the TMP421 sensor temperature reporting.</li>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 System"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"","value":"HPE ProLiant SL4500 Chassis"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_NIC","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GEBTP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHC6FG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745425450","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB6000GEBTP"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB6000GEBTP Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"16643795","datemodified":"2021-08-26T20:22:37","file_list":["/CP048370_BUILD_2.data","/CP048370.vmexe","/CP048370.vmexe64","/CP048370.vmfile","/CP048370_VMw.zip","/CP048370.xml","/payload.json","/CP048370_VMw.zip/index.xml","/CP048370_VMw.zip/vendor-index.xml","/CP048370_VMw.zip/metadata.zip","/CP048370_VMw.zip/vib20/CP048370/HPE_bootbank_CP048370_HPG4.2-7.0.0.15843807.vib","/CP048370_VMw.zip/metadata.zip/vendor-index.xml","/CP048370_VMw.zip/metadata.zip/vmware.xml","/CP048370_VMw.zip/metadata.zip/vibs/CP048370--1305886891935817215.xml","/CP048370_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048370_HPG4.2-7.0.0.15843807.xml"],"md5sum":"df108452e6266d553ccb0c2f4787007d","name":"CP048370.zip","release":"2021-08-26T20:17:33","revision":"0","sha1sum":"e97740543ac05e855c7f64bf8b22a9b9fdd35903","size":"15MB","target_guids":["002340a5-4d00-3642-3030-304745425450"],"type_of_change":"1","version":"HPG4","vib_list":[{"name":"CP048370","version":"HPG4.2-7.0.0.15843807"}]}],"id":{"product":"f08c2998f0194b1483b2e21050a3b5a3","version":"303a095dffab410caaf6224b981c4413"},"installation":{"command":"CP040543.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB6000GEBTP Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB6000GEBTPドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB6000GEBTP","target_guid":"002340a5-4d00-3642-3030-304745425450","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-07T20:39:27","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000GEBTP","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GWSSC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757535343","Version":"HPG3"},{"DeviceName":"MK000960GWSSD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757535344","Version":"HPG3"},{"DeviceName":"MK001920GWSSE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304757535345","Version":"HPG3"},{"DeviceName":"MK003840GWSSF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-304757535346","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MK000480GWSSC, MK000960GWSSD, MK001920GWSSE and MK003840GWSSF Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MK000480GWSSC、MK000960GWSSD、MK001920GWSSEおよびMK003840GWSSFドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MK000480GWSSC, MK000960GWSSD, MK001920GWSSE and MK003840GWSSF&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG2</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG2<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp; &nbsp;</strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"6301248","datemodified":"2021-07-23T09:26:50","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-f693ccc138-HPG3-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-f693ccc138-HPG3-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-f693ccc138-HPG3-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-f693ccc138-HPG3-3.1/CP048206.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-f693ccc138-HPG3-3.1/GSM883G3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-f693ccc138-HPG3-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-f693ccc138-HPG3-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-f693ccc138-HPG3-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-f693ccc138-HPG3-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048206.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048206.scexe"],"md5sum":"8a6bc85e8e4629745d32e114ee7f4a03","name":"firmware-hdd-f693ccc138-HPG3-3.1.x86_64.rpm","release":"2021-07-23T09:14:09","revision":"0","sha1sum":"3cebc2b0fc6d20c9f3219f8f4a2af2b13820d181","size":"6MB","target_guids":["4d2340a5-304b-3030-3438-304757535343","4d2340a5-304b-3030-3936-304757535344","4d2340a5-304b-3130-3932-304757535345","4d2340a5-304b-3330-3834-304757535346"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"17be7af3223241a4bef4e8f0da8afac5","version":"f0e040155968423da194497600d2ffc0"},"installation":{"command":"CP041676.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート:</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします: </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます:\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>（.rpm拡張子の付いていないrpmファイル名）を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を解凍するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するには Service Pack for ProLiant から以下の手順に従ってください:</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン:</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MK000480GWSSC, MK000960GWSSD, MK001920GWSSE and MK003840GWSSF Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64)- MK000480GWSSC、 MK000960GWSSD、MK001920GWSSEおよびMK003840GWSSFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MK003840GWSSF","target_guid":"4d2340a5-304b-3330-3834-304757535346","type":"sata"},{"id":"MK001920GWSSE","target_guid":"4d2340a5-304b-3130-3932-304757535345","type":"sata"},{"id":"MK000960GWSSD","target_guid":"4d2340a5-304b-3030-3936-304757535344","type":"sata"},{"id":"MK000480GWSSC","target_guid":"4d2340a5-304b-3030-3438-304757535343","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T11:33:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK001920GWSSE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWSSC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWSSD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK003840GWSSF","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE QLogic FastLinQ 10/25/50 Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 12 x86_64."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12 x86_64で動作するHPE QLogic FastLinQ 10/25/50 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"11685327","datemodified":"2021-08-11T14:23:45","file_list":["./etc/dracut.conf.d/fastlinq.conf","./lib/firmware/qed","./lib/firmware/qed/qed_init_values_zipped-8.50.18.0.bin","./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/qlgc-fastlinq","./lib/modules/4.12.14-120-default/updates/qlgc-fastlinq/qed.ko","./lib/modules/4.12.14-120-default/updates/qlgc-fastlinq/qede.ko","./lib/modules/4.12.14-120-default/updates/qlgc-fastlinq/qedf.ko","./lib/modules/4.12.14-120-default/updates/qlgc-fastlinq/qedi.ko","./lib/modules/4.12.14-120-default/updates/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/qlgc-fastlinq-kmp-default/component.xml"],"md5sum":"12d66fcf31bbea34641354200ef6b987","name":"qlgc-fastlinq-kmp-default-8.55.14.0_k4.12.14_120-2.sles12sp5.x86_64.rpm","release":"2021-08-11T14:10:17","revision":"0","sha1sum":"90500cf451ad8d2c475a1f3a81ba93e789ed0a71","size":"11MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfc93be64"],"type_of_change":"0","version":"8.55.14.0-2"}],"id":{"product":"beee944cb2a04bc7ba023dbf3bec720d","version":"23f0f91bdb794b569d0912874fadba22"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>Download README for any additional installation instructions.</p>\n"},{"lang":"ja","x_late":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>\n\n<p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>\n\n<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>\n\n<p> </p>\n\n<p>その他のインストール手順についてのREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE QLogic FastLinQ 10/25/50 GbE Drivers for SUSE Linux Enterprise Server 12 x86_64"},{"lang":"ja","x_late":"SUSE Linux Enterprise Server 12 x86_64用HPE QLogic FastLinQ 10/25/50 GbEドライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"8070","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021d","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021f","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0074","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770074","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0073","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770073","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-807015900220","type":"pci","ven":"1077"},{"dev":"8070","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8070159002bd","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0070","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770070","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0069","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770069","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0068","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770068","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0071","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770071","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0072","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770072","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021a","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021b","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0070","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770070","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0069","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770069","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0068","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770068","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0071","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770071","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0072","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770072","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0074","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770074","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0073","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770073","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This product corrects an issue where the driver fails to load in NPAR mode when RoCE Data Center Quantized Congestion Notification (DCQCN) is enabled.</li>\n\t<li>This product corrects an issue ethernet data rate limiting unable on VFs.</li>\n\t<li>This product addresses a system crash seen when injecting a fw_assert on a NIC PF.</li>\n\t<li>This product addresses a system crash seen when limiting number of MSI-X interrupt vectors as requested for VFs</li>\n\t<li>This product addresses a system crash seen when unloading and reloading the RoCE driver only.</li>\n\t<li>This product addresses a system crash seen during multiple reboots of virtual machines using VFs and RDMA.</li>\n\t<li>This product addresses a the connection recover failed with heavy traffic</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where the 10GbE Adapters having an DNS resolution issue on Kubernetes container-orchestration system</li>\n\t<li>This product addresses an issue where system crashes after PCIe error injection multiple times on HPE SDFlex system</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"qlgc-fastlinq-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EK0800JVYPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304b-3830-304a5659504e","Version":"HPD7"},{"DeviceName":"EO1600JVYPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-314f-3630-304a56595050","Version":"HPD7"},{"DeviceName":"MK0800JVYPQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304b-3830-304a56595051","Version":"HPD7"},{"DeviceName":"MO1600JVYPR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304a56595052","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EK0800JVYPN, EO1600JVYPP, MK0800JVYPQ and MO1600JVYPR"},{"lang":"ja","x_late":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EK0800JVYPN、EO1600JVYPP、MK0800JVYPQ、およびMO1600JVYPR"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- EK0800JVYPN, EO1600JVYPP, MK0800JVYPQ and MO1600JVYPR Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD7</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD7 that results in SSD failure at 40,000 hours of operation (i.e., 4 years, 205 days 16 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us</a>.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"3322632","datemodified":"2021-07-25T20:41:07","file_list":["cp048651.xml","cpqsetup.exe","payload.json","PLTGIID7.rel","setup.dll"],"md5sum":"46c7e835dcfc9acae52a3b2c6a3f6dcd","name":"cp048651.exe","release":"2021-07-25T20:34:11","revision":"0","sha1sum":"f0c618429a31b9a658599770aaab8ea710b1df38","size":"3MB","target_guids":["002340a5-4500-304b-3830-304a5659504e","002340a5-4500-314f-3630-304a56595050","002340a5-4d00-304b-3830-304a56595051","002340a5-4d00-314f-3630-304a56595052"],"type_of_change":"2","version":"HPD7"}],"id":{"product":"a5c4c8dc7b4a47d3abf311a168b0a29d","version":"cdbbc8bf0dee4dba9d7ac57a6abf71f1"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EK0800JVYPN, EO1600JVYPP, MK0800JVYPQ and MO1600JVYPR Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for Windows (x64) - EK0800JVYPN、EO1600JVYPP、MK0800JVYPQ、およびMO1600JVYPRドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MO1600JVYPR","target_guid":"002340a5-4d00-314f-3630-304a56595052","type":"sas"},{"id":"EO1600JVYPP","target_guid":"002340a5-4500-314f-3630-304a56595050","type":"sas"},{"id":"MK0800JVYPQ","target_guid":"002340a5-4d00-304b-3830-304a56595051","type":"sas"},{"id":"EK0800JVYPN","target_guid":"002340a5-4500-304b-3830-304a5659504e","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T18:49:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD7 that results in SSD failure at 40,000 hours of operation (i.e., 4 years, 205 days 16 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us</a>.</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD7 that results in SSD failure at 40,000 hours of operation (i.e., 4 years, 205 days 16 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us</a>.</li>\n</ul>","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EK0800JVYPN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO1600JVYPP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO1600JVYPR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MK0800JVYPQ","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG0300FCSPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SED2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3330-304643535048","Version":"HPD2"},{"DeviceName":"EG0450FCSPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SED2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3435-30464353504b","Version":"HPD2"},{"DeviceName":"EG0600FCSPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SED2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3630-30464353504c","Version":"HPD2"},{"DeviceName":"EG0900FCSPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SED2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3930-30464353504e","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EG0300FCSPH, EG0450FCSPK, EG0600FCSPL and EG0900FCSPN"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EG0300FCSPH、EG0450FCSPK、EG0600FCSPL、およびEG0900FCSPN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG0300FCSPH, EG0450FCSPK, EG0600FCSPL&nbsp;and EG0900FCSPN Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"15978078","datemodified":"2021-08-30T04:35:25","file_list":["/CP048255_BUILD_2.data","/CP048255.vmexe","/CP048255.vmexe64","/CP048255.vmfile","/CP048255_VMw.zip","/CP048255.xml","/payload.json","/CP048255_VMw.zip/index.xml","/CP048255_VMw.zip/vendor-index.xml","/CP048255_VMw.zip/metadata.zip","/CP048255_VMw.zip/vib20/CP048255/HPE_bootbank_CP048255_HPD2.2-7.0.0.15843807.vib","/CP048255_VMw.zip/metadata.zip/vendor-index.xml","/CP048255_VMw.zip/metadata.zip/vmware.xml","/CP048255_VMw.zip/metadata.zip/vibs/CP048255--8613360112209491030.xml","/CP048255_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048255_HPD2.2-7.0.0.15843807.xml"],"md5sum":"bf933df49f88ce3231c8d1e5418952e5","name":"CP048255.zip","release":"2021-08-30T04:30:20","revision":"0","sha1sum":"a4377182e83e9473cb1b2807ed534b6cf862af3e","size":"15MB","target_guids":["002340a5-4500-3047-3330-304643535048","002340a5-4500-3047-3435-30464353504b","002340a5-4500-3047-3630-30464353504c","002340a5-4500-3047-3930-30464353504e"],"type_of_change":"1","version":"HPD2","vib_list":[{"name":"CP048255","version":"HPD2.2-7.0.0.15843807"}]}],"id":{"product":"4b93b2211c95475cbce045b32636c34c","version":"118de07f91df463085375b94d54ef1f9"},"installation":{"command":"CP040531.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EG0300FCSPH, EG0450FCSPK, EG0600FCSPL and EG0900FCSPN Drives"},{"lang":"ja","x_late":"オンラインHDD/SDDフラッシュコンポーネントfor VMware ESXi - EG0300FCSPH、EG0450FCSPK、EG0600FCSPL、およびEG0900FCSPNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG0300FCSPH","target_guid":"002340a5-4500-3047-3330-304643535048","type":"sas"},{"id":"EG0450FCSPK","target_guid":"002340a5-4500-3047-3435-30464353504b","type":"sas"},{"id":"EG0600FCSPL","target_guid":"002340a5-4500-3047-3630-30464353504c","type":"sas"},{"id":"EG0900FCSPN","target_guid":"002340a5-4500-3047-3930-30464353504e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-02T09:11:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG0450FCSPK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0300FCSPH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0900FCSPN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0600FCSPL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the SRIOV virtual function drivers for the HPE Intel ixgbe Ethernet NICs running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 8で動作するHPE Intel ixgbe Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"55081","datemodified":"2021-01-19T03:12:24","file_list":["./etc/depmod.d/hp-ixgbevf.conf","./etc/dracut.conf.d/hp-ixgbevf-oob.conf","./lib/modules/4.18.0-193.el8.x86_64","./lib/modules/4.18.0-193.el8.x86_64/extra","./lib/modules/4.18.0-193.el8.x86_64/extra/hp-ixgbevf","./lib/modules/4.18.0-193.el8.x86_64/extra/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/kmod-hp-ixgbevf/component.xml"],"md5sum":"0cf510c6030263e52ff037331af8a9e7","name":"kmod-hp-ixgbevf-4.9.3-1.rhel8u2.x86_64.rpm","release":"2021-01-19T03:00:05","revision":"0","sha1sum":"89e2ceafb185936ee086408fc31a20380269d6b2","size":"53KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eca2355bb8"],"type_of_change":"0","version":"4.9.3-1"},{"bytes":"55132","datemodified":"2021-01-19T03:10:26","file_list":["./etc/depmod.d/hp-ixgbevf.conf","./etc/dracut.conf.d/hp-ixgbevf-oob.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/hp-ixgbevf","./lib/modules/4.18.0-240.el8.x86_64/extra/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/kmod-hp-ixgbevf/component.xml"],"md5sum":"b6f96ed78fcdbbd1febe845045fbb022","name":"kmod-hp-ixgbevf-4.9.3-1.rhel8u3.x86_64.rpm","release":"2021-01-19T03:00:05","revision":"0","sha1sum":"2546479b1a6a0701e71a5944e67aec17bc6be255","size":"53KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eca2355bb8"],"type_of_change":"0","version":"4.9.3-1"}],"id":{"product":"30f1903e29c9444e8763652af6b41477","version":"7daec0f74d024ffc917804c41ba8db47"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Intel ixgbevf Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE Intel ixgbevfドライバー for Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"},{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c192d","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c211a","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"},{"dev":"152E","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d3","type":"pci","ven":"8086"},{"dev":"1530","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product update Linux kernel documentation and Configure IRQ affinity tools</p>\n","latest_fixes_x_late":"<p>This product corrects an issue which errata kernel loads inbox driver instead of this component after booting into OS</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>This product now supports Red Hat Enterprise Linux 8 update 2 and Red Hat Enterprise Linux 8 update 3</li>\n\t<li>This product enhances reliability via adding support for new mailbox communication between PF(Physical Function) and VF(Virtual Function) and remove its potential flaws that may lead to the undefined or faulty behavior</li>\n\t<li>This product enhances compatibility where new mailbox api implementation is alo compatible with old drivers</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-hp-ixgbevf","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbevf","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbevf","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbevf","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6239329","datemodified":"2021-05-18T04:48:53","file_list":["./usr/lib/i386-linux-gnu/firmware-system-p95-2.90_2021_04_29-1.1","./usr/lib/i386-linux-gnu/firmware-system-p95-2.90_2021_04_29-1.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-system-p95-2.90_2021_04_29-1.1/.setup","./usr/lib/i386-linux-gnu/firmware-system-p95-2.90_2021_04_29-1.1/CP047865.xml","./usr/lib/i386-linux-gnu/firmware-system-p95-2.90_2021_04_29-1.1/P95_2.90_04_29_2021.signed.flash","./usr/lib/i386-linux-gnu/firmware-system-p95-2.90_2021_04_29-1.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-system-p95-2.90_2021_04_29-1.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP047865.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP047865.scexe"],"md5sum":"54ab8347c8a16f900a32fec1a328910b","name":"firmware-system-p95-2.90_2021_04_29-1.1.i386.rpm","release":"2021-05-18T04:38:05","revision":"0","sha1sum":"b56bf880705fedde62c4249b6f6ae9880cb90b51","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021"}],"id":{"product":"13b837d640ac455ba223e985cd1fb165","version":"68e5e251f6a84733aedd935dc1c4098d"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HPE ProLiant Agentless Management Service (<strong>AMS</strong>) and HPE SNMP Agents (<strong>SNMP Agents</strong>) are both running.&nbsp; HPE does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager 8.0.0 or later, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、iLOとの通信ができない場合に失敗します。  これは、HPE ProLiant Agentless Management Service (<strong>AMS</strong>)およびHPE SNMPエージェント(<strong>SNMP Agents</strong>)の両方が実行されているときに発生します。  HPEでは、AMSおよびSNMPエージェントを同時に実行させないことを推奨します。  「iLO device not found」エラーが発生した場合、AMSまたはSNMPエージェントを停止させて、再度フラッシュコンポーネントを実行します。<br />\n<br />\n<br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上のSmart Update Manager 8.0.0以降を使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant ML150 Gen9 (P95) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant ML150 Gen9(P95)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Oracle Linux 7","platform":"Oracle Enterprise Linux","sr":"OEM"},{"major":"6","minor":"0","name":"Oracle Linux 6 (AMD64/EMT64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-05T06:44:16","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"}],"sw_keys":[{"name":"P95","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB8000GFECR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRPTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3842-3030-304746454352","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB8000GFECR"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB8000GFECR Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPG5</p>\n\n<p><strong>Previous Version of Firmware:</strong></p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp; HPG5<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3532824","datemodified":"2021-07-25T16:10:18","file_list":["cp048618.xml","cpqsetup.exe","payload.json","setup.dll","SMKRPTG6.rel"],"md5sum":"8df68ace593e8dffb988ad283cd9ac02","name":"cp048618.exe","release":"2021-07-25T16:03:04","revision":"0","sha1sum":"cd843488484b5555d6645151ab15b3fff3119fcb","size":"3MB","target_guids":["002340a5-4d00-3842-3030-304746454352"],"type_of_change":"1","version":"HPG6"}],"id":{"product":"82d1b2ac21094989a9b2118ea6829df2","version":"ab89b8e954b34458b8eabf3717871671"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB8000GFECR Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB8000GFECRドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB8000GFECR","target_guid":"002340a5-4d00-3842-3030-304746454352","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T12:25:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB8000GFECR","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HP Ethernet 1Gb 2-port 332i Adapter (22E8)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//332i-2x1G-14E4-165F-103C-22E8.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C22E8","Version":"20.18.31"},{"DeviceName":"HP Ethernet 1Gb 2-port 330i Adapter (22BD)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//330i-2x1G-14E4-1665-103C-22BD.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-1665103C22BD","Version":"20.18.31"},{"DeviceName":"HP Ethernet 1Gb 2-port 332T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//332T-2x1G-14E4-165F-103C-1786.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C1786","Version":"20.18.31"},{"DeviceName":"HP Ethernet 1Gb 4-port 331FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331FLR-4x1G-14E4-1657-103C-169D.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C169D","Version":"20.18.31"},{"DeviceName":"HP Ethernet 1Gb 4-port 331T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331T-4x1G-14E4-1657-103C-3383.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C3383","Version":"20.18.31"},{"DeviceName":"HP Ethernet 1Gb 4-port 331i Adapter (22BE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331i-4x1G-14E4-1657-103C-22BE.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C22BE","Version":"20.18.31"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NX1 Gigabit Ethernet NICs Boot code, PXE, NCSI, and CCM code running under vSphere 6.5, 6.7, and 7.0."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"9685239","datemodified":"2021-01-21T07:51:41","file_list":["/CP045013_BUILD_13.data","/CP045013.vmexe","/CP045013.vmexe64","/CP045013.vmfile","/CP045013_VMw.zip","/CP045013.xml","/payload.json","/CP045013_VMw.zip/index.xml","/CP045013_VMw.zip/vendor-index.xml","/CP045013_VMw.zip/metadata.zip","/CP045013_VMw.zip/vib20/CP045013/HPE_bootbank_CP045013_1.28.6.13-7.0.0.15843807.vib","/CP045013_VMw.zip/metadata.zip/vendor-index.xml","/CP045013_VMw.zip/metadata.zip/vmware.xml","/CP045013_VMw.zip/metadata.zip/vibs/CP045013-7224660966313214503.xml","/CP045013_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045013_1.28.6.13-7.0.0.15843807.xml"],"md5sum":"ce28c2452eb153203bab072c15fd6bfb","name":"CP045013.zip","release":"2021-01-21T07:49:05","revision":"0","sha1sum":"9a1ccc2766df74cdbac5ac003ef0764b17116294","size":"9MB","target_guids":["a6b1a447-382a-5a4f-14E4-165F103C22E8","a6b1a447-382a-5a4f-14E4-1665103C22BD","a6b1a447-382a-5a4f-14E4-165F103C1786","a6b1a447-382a-5a4f-14E4-1657103C169D","a6b1a447-382a-5a4f-14E4-1657103C3383","a6b1a447-382a-5a4f-14E4-1657103C22BE"],"type_of_change":"0","version":"1.28.6","vib_list":[{"name":"CP045013","version":"1.28.6.13-7.0.0.15843807"}]}],"id":{"product":"1a455792d85d4dea8d7373fc92fb5b20","version":"648f0b90d7c2438b82851940e28f4419"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Broadcom tg3 Ethernet Driver version 3.137e-3 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"6.6"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"3.137e-3","description":"HP Broadcom tg3 Ethernet Driver version 3.137e-3 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Manual installation instructions:</p>\n\n<ol>\n\t<li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li>\n\t<li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li>\n\t<li>Unzip the CPxxxxxx.zip file.</li>\n\t<li>Install the VMware component.\n\t<ul>\n\t\t<li>a. For ESXi 7.0 targets: esxcli &nbsp;software component apply &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply &ndash;d /tmp/CPxxxxxx_VMware.zip&quot;)</li>\n\t\t<li>b. For ESXi 6.x targets: esxcli software vib install &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install &ndash;d /tmp/CPxxxxxx_VMw.zip&quot;)</li>\n\t</ul>\n\t</li>\n\t<li>.Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li>\n\t<li>Execute the component with the command set options &nbsp;s, -f, -e, -g, &nbsp;etc. if required. When execution is complete the flash engine will have performed the flash operation as directed.</li>\n\t<li>Clean up the Smart Component:\n\t<ul>\n\t\t<li>a. Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li>\n\t\t<li>b. To clean up the Smart Component:\n\t\t<ul>\n\t\t\t<li>i.For ESXi 7.0 targets: esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t\t\t<li>ii.For ESXi 6.x targets: esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>c.Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li>\n\t</ul>\n\t</li>\n\t<li>If reboot is required to complete the firmware installation, reboot your system.</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 VMware 的 HPE Broadcom NX1 線上韌體升級公用程式"},{"lang":"en","x_late":"HPE Broadcom NX1 Online Firmware Upgrade Utility for VMware"},{"lang":"ko","x_late":"VMware용 HPE Broadcom NX1 온라인 펌웨어 업그레이드 유틸리티"},{"lang":"cn","x_late":"VMware版HPE Broadcom NX1在线固件升级实用程序"},{"lang":"ja","x_late":"HPE Broadcom NX1オンライン ファームウェアアップグレードユーティリティ for VMware"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"165F","subdev":"22E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c22e8","type":"pci","ven":"14E4"},{"dev":"1665","subdev":"22BD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1665103c22bd","type":"pci","ven":"14E4"},{"dev":"165F","subdev":"1786","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c1786","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"169D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c169d","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"3383","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c3383","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"22BE","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c22be","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects the wrong spare number while it was originally not the same as what was written on the label of package.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>This product addresses an issue about lack of information under AHS log.</li>\n\t<li>This product addresses an RSOD issue which appeared intermittently during POST after having a warm reboot.</li>\n\t<li>This product addresses a modification on help string of Family Firmware Version.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"BCM","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWJAN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-3047574a414e","Version":"HPG1"},{"DeviceName":"MB002000GWFWA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757465741","Version":"HPG1"},{"DeviceName":"MB004000GWFWB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757465742","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB001000GWJAN, MB002000GWFWA and MB004000GWFWB"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB001000GWJAN、MB002000GWFWA および MB004000GWFWB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for&nbsp;Windows (x64)&nbsp;- MB001000GWJAN, MB002000GWFWA and MB004000GWFWB Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3396800","datemodified":"2021-07-23T19:23:00","file_list":["cp048558.xml","cpqsetup.exe","payload.json","setup.dll","TATCATSATAG1.REL"],"md5sum":"b288ba95315cda1d1a1646d432e9f187","name":"cp048558.exe","release":"2021-07-23T19:15:04","revision":"0","sha1sum":"d8d583957a7881c2930d1da1d16d2568469ed4bf","size":"3MB","target_guids":["4d2340a5-3042-3130-3030-3047574a414e","4d2340a5-3042-3230-3030-304757465741","4d2340a5-3042-3430-3030-304757465742"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"3d1400a6e0204fb498134f7e6e3f374a","version":"59d5ad6748fe48afb3192b88770d4f8b"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB  Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB001000GWJAN、MB002000GWFWAおよびMB004000GWFWBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB004000GWFWB","target_guid":"4d2340a5-3042-3430-3030-304757465742","type":"sata"},{"id":"MB002000GWFWA","target_guid":"4d2340a5-3042-3230-3030-304757465741","type":"sata"},{"id":"MB001000GWJAN","target_guid":"4d2340a5-3042-3130-3030-3047574a414e","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T05:50:30","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB004000GWFWB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB001000GWJAN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB002000GWFWA","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the SRIOV virtual function drivers for the HPE Blade Intel ixgbe Ethernet NICs running under SUSE Linux Enterprise Server 12."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12で動作するHPE Blade Intel ixgbe Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1027405","datemodified":"2021-03-08T18:25:46","file_list":["./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/hp-ixgbevf","./lib/modules/4.12.14-94.41-default/updates/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/hp-ixgbevf_bl-kmp-default/component.xml"],"md5sum":"9b19062e20d318dc6d2be41b872182be","name":"hp-ixgbevf_bl-kmp-default-4.9.3_k4.12.14_94.41-1.sles12sp4.x86_64.rpm","release":"2021-03-08T18:13:11","revision":"0","sha1sum":"69e8751f557da72218c9b58062d693d082422476","size":"0MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec93bdb747"],"type_of_change":"0","version":"4.9.3-1"},{"bytes":"1055055","datemodified":"2021-03-08T18:21:31","file_list":["./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/hp-ixgbevf","./lib/modules/4.12.14-120-default/updates/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/hp-ixgbevf_bl-kmp-default/component.xml"],"md5sum":"d4788382bd188db5898b7abb8b5f0bfb","name":"hp-ixgbevf_bl-kmp-default-4.9.3_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-03-08T18:13:11","revision":"0","sha1sum":"2d3b57753612f3f550c0a667f58118c5c5cc5ab8","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec93bdb747"],"type_of_change":"0","version":"4.9.3-1"}],"id":{"product":"88b0a89daaf348e9967e08f08cad5650","version":"7e3f1a803b874274afd2472a9cd4d129"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Intel ixgbevf Drivers for SUSE Linux Enterprise Server 12"},{"lang":"ja","x_late":"HPE Blade Intel ixgbevfドライバーfor SUSE Linux Enterprise Server 12"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c18d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>These drivers have been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 12 SP5.</p>\n","curr_fixes_x_late":"<p>This product corrects an issue seen when enabling SRIOV, where the VFs have the same, duplicated MAC address.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"hp-ixgbevf_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbevf_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbevf_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbevf_bl-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter and mezzanine host bus adapters. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"4169878","datemodified":"2021-08-27T03:27:51","file_list":["./etc/dracut.conf.d/qla2xxx.conf","./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/qlgc-qla2xxx","./lib/modules/4.12.14-120-default/updates/qlgc-qla2xxx/qla2xxx.ko","./lib/modules/4.12.14-120-default/updates/qlgc-qla2xxx/tcm_qla2xxx.ko","./usr/share/smartupdate/qlgc-qla2xxx-kmp-default/component.xml"],"md5sum":"521a61c7c8ded0a77cadba75b0af55c8","name":"qlgc-qla2xxx-kmp-default-10.02.01.00.a14_k1_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-08-27T03:22:27","revision":"0","sha1sum":"86759b4beaf384b32c5be545d77901ace3eaa55b","size":"3MB","target_guids":[],"type_of_change":"1","version":"10.02.01.00.a14-k1"}],"id":{"product":"bdd3cc56d4c64c1b92278e626bb94b0b","version":"7621d32011134fce8e0102a832defe1f"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh qlgc-qla2xxx-4.6.28-20.sles12sp2.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</p>\n\n<p>Rewrite of same Driver version has to be performed using &ndash;force or --replacepkgs with --nodeps option</p>\n\n<p>Example: rpm &ndash;Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm &ndash;force --nodeps</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; rpm &ndash;Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm &ndash;replacepkgs --nodeps</p>\n\n<p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"SUSE Linux Enterprise Server 12 Service Pack 5 Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters and Mezzanine Host Bus Adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015D","subven":"1077","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015C","subven":"1077","target_guid":"","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-18T06:47:30","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to driver version 10.02.01.00.a14-k1</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"qlgc-qla2xxx-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the SRIOV virtual function drivers for the HPE Intel i40e Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Intel i40e Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1852408","datemodified":"2021-08-24T15:35:14","file_list":["./etc/depmod.d/hp-iavf.conf","./etc/dracut.conf.d/hp-iavf-oob.conf","./lib/modules/5.3.18-57-default","./lib/modules/5.3.18-57-default/updates","./lib/modules/5.3.18-57-default/updates/hp-iavf","./lib/modules/5.3.18-57-default/updates/hp-iavf/iavf.ko","./usr/share/smartupdate/hp-iavf-kmp-default/component.xml"],"md5sum":"20af4a75ade72de26f2483f2893d3fa2","name":"hp-iavf-kmp-default-4.2.7_k5.3.18_57-1.sles15sp3.x86_64.rpm","release":"2021-08-24T15:23:06","revision":"0","sha1sum":"72e2f87156adb84f2843050609ee19d88ffec5e1","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec8201731a"],"type_of_change":"0","version":"4.2.7-1"},{"bytes":"1804068","datemodified":"2021-08-24T15:32:23","file_list":["./etc/depmod.d/hp-iavf.conf","./etc/dracut.conf.d/hp-iavf-oob.conf","./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/hp-iavf","./lib/modules/5.3.18-22-default/updates/hp-iavf/iavf.ko","./usr/share/smartupdate/hp-iavf-kmp-default/component.xml"],"md5sum":"87be7480268b443c680090af6642a420","name":"hp-iavf-kmp-default-4.2.7_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-08-24T15:23:06","revision":"0","sha1sum":"82eb249166630a6c6e15d9fdeaf1793889848012","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec8201731a"],"type_of_change":"0","version":"4.2.7-1"}],"id":{"product":"5156ee2ce74d4685bd9c2931c6170220","version":"2f72a814d8fe4de18ea699ae3617b9e2"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"},{"lang":"ja","x_late":"<p>インストールのノートについてREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Intel iavf Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE Intel iavfドライバー for SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"1592","subdev":"0002","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159280860002","type":"pci","ven":"8086"},{"dev":"1592","subdev":"0006","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159280860006","type":"pci","ven":"8086"},{"dev":"159B","subdev":"0003","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159b80860003","type":"pci","ven":"8086"},{"dev":"159B","subdev":"0005","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159b80860005","type":"pci","ven":"8086"},{"dev":"1593","subdev":"0005","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159380860005","type":"pci","ven":"8086"},{"dev":"1592","subdev":"000E","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-15928086000e","type":"pci","ven":"8086"},{"dev":"1593","subdev":"000C","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-15938086000c","type":"pci","ven":"8086"},{"dev":"1581","subdev":"00F8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1581159000f8","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul style=\"list-style-type:square\">\n\t<li>This product now supports Suse Linux Enterprise Server 15 Service Pack 2</li>\n\t<li>This product now supports the following servers:</li>\n</ul>\n\n<p style=\"margin-left:80px; margin-right:0px; text-align:left\">&nbsp;HPE Superdome Flex 280 &nbsp;<br />\n&nbsp;HPE Superdome Flex Server &nbsp;<br />\n&nbsp;HPE Superdome Flex 2&nbsp;</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 15 Service Pack 3</p>\n","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where HyperV Ping is lost after change MTU on VF interface in a VM linux</li>\n\t<li>This product addresses an issue which could lead to traffic interrupts and full traffic stop through the bond when VFs were added to bonding-alb/tlb modes</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"hp-iavf-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-iavf-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-iavf-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-iavf-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the HPE Dual 8GB microSD Enterprise Midline USB"},{"lang":"ja","x_late":"このSmartコンポーネントは、HPEデュアル 8GB MicroSD Enterprise Midline USBのファームウェアを提供します"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online Smart Component which upgrades firmware on HPE Dual 8GB&nbsp;microSD Enterprise Midline USB&nbsp;</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 1.3.2.215<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 1.3.2.215<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 1.3.2.212<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>\n\t<p>None.</p>\n\t</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>To show corresponding&nbsp;HPE Dual 8GB&nbsp;Micron SD&nbsp;&nbsp;part number&nbsp;in Agentless Management Service version 11.2.0 or later.</li>\n</ul>\n\n<p><strong>Known Issues:</strong>&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"},{"lang":"ja","x_late":"<p><strong>提供名：</strong><br />\n     HPE Dual 8GB microSD Enterprise Midline USB上のファームウェアをアップグレードするオンラインSmartコンポーネント </p>\n\n<p><strong>リリースバージョンおよび/または日付:</strong><br />\n     1.3.2.215<br />\n<br />\n<strong>最新の推奨またはクリティカルバージョン：</strong><br />\n     1.3.2.215<br />\n<br />\n<strong>前のファームウェアバージョン：</strong><br />\n     1.3.2.212<br />\n<br />\n<strong>ファームウェアの関連性：</strong><br />\n     なし</p>\n\n<p><strong>改善点/新しい機能：</strong></p>\n\n<ul>\n\t<li>\n\t<p>なし。</p>\n\t</li>\n</ul>\n\n<p><strong>修正された問題点：</strong></p>\n\n<ul>\n\t<li>Agentless Management Serviceバージョン11.2.0以降で対応するHPEデュアル8GBミクロンSDの製品番号を表示する。</li>\n</ul>\n\n<p><strong>既知の問題点：</strong> <br />\n     なし</p>\n"}],"files":[{"bytes":"1059079","datemodified":"2018-11-13T03:09:46","file_list":["/CP037940.vmexe","/CP037940.vmfile","/CP037940.xml","/README.txt"],"md5sum":"72e5ac789c296b7a5ca15ba8551f6786","name":"CP037940.zip","release":"2018-11-13T08:56:03","revision":"0","sha1sum":"c5eb9ce02c807748bfee8e39386acd16823a5515","size":"1MB","target_guids":[],"type_of_change":"1","version":"1.3.2.215","vib_list":[]}],"id":{"product":"afd60bda7b524c9d827bf70af6eb6201","version":"f556c312fdc24859bf6fde57b13db68f"},"installation":{"command":"CP037940.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p>\n\n<p style=\"margin-left: 40px;\"><strong>Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"text-decoration: none; color: blue;\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;<br />\n<strong>To use HP Insight Control for vCenter:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HP Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong></p>\n\n<p style=\"margin-left: 40px;\"><strong>リモートオンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加しました。</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"text-decoration: none; color: blue;\">http://www.hpe.com/info/spp/documentation</a><br />\n <br />\n<strong>HP Insight Control for vCenterを使用するには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vSphereクライアントにログインします。</li>\n\t<li>インベントリツリーのサーバーまたはクラスターを選択します。</li>\n\t<li>HPE Insight Managementタブをクリックします。</li>\n\t<li>Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルをテンポラリディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします</li>\n\t<li>コマンドを使用してCPXXXXXX.vmexeが実行可能であることを確認します：</li>\n</ul>\n\n<p>             chmod +x CPXXXXXX.vmexe    </p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例：./CPXXXXXX.vmexe</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash component for VMware ESXi - HPE Dual 8GB microSD USB"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for VMware ESXi - HPEデュアル 8GB MicroSD USB"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_operating_systems":[{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"5","minor":"5","name":"VMware vSphere 5.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-11-22T08:39:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>To show corresponding&nbsp;HPE Dual 8GB&nbsp;Micron SD&nbsp;&nbsp;part number&nbsp;in Agentless Management Service version 11.2.0 or later.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>To show corresponding&nbsp;HPE Dual 8GB&nbsp;Micron SD&nbsp;&nbsp;part number&nbsp;in Agentless Management Service version 11.2.0 or later.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"}],"sw_keys":[{"name":"HPE Dual 8GB microSD USB","sw_key_expectedpath":"firmware:sd:microsdusb"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWWQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNETG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757575155","Version":"HPG2"},{"DeviceName":"MB006000GWWQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNETG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304757575154","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB008000GWWQU and MB006000GWWQT Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB008000GWWQUおよびMB006000GWWQTドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB008000GWWQU and MB006000GWWQT Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5609760","datemodified":"2021-07-23T09:15:21","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG2-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG2-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG2-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG2-4.1/CP048199.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG2-4.1/SCIMARRNETG2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG2-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG2-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG2-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG2-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048199.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048199.scexe"],"md5sum":"02495a23949ae1cf89c4679a913c7174","name":"firmware-hdd-18e328f036-HPG2-4.1.x86_64.rpm","release":"2021-07-23T09:02:11","revision":"0","sha1sum":"62b382f396ce9d160d20f5e97c264404d6bdd6e1","size":"5MB","target_guids":["4d2340a5-3042-3830-3030-304757575155","4d2340a5-3042-3630-3030-304757575154"],"type_of_change":"1","version":"HPG2"}],"id":{"product":"862d36dd920c478ca6dcfdb5f392893a","version":"1add6f474af546e091f7460aa488c903"},"installation":{"command":"CP043252.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB008000GWWQU and MB006000GWWQT Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB008000GWWQUおよびMB006000GWWQTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB008000GWWQU","target_guid":"4d2340a5-3042-3830-3030-304757575155","type":"sata"},{"id":"MB006000GWWQT","target_guid":"4d2340a5-3042-3630-3030-304757575154","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T11:06:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>&nbsp;Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000GWWQT","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB008000GWWQU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the HPE Apollo 2000 - SAS Expander"},{"lang":"ja","x_late":"このSmartコンポーネントは、HPE Apollo 2000 - SASエキスパンダーのファームウェアを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Supplemental Update / Online ROM Flash Component for Linux &ndash; Apollo 2000 System</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.52<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;1.00(C)<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;NA<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Fixed an issue in the HPE Apollo 2000 System SAS Expander FW where the HDD Zoning Table would be set to default after upgrading to 1.51</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"},{"lang":"ja","x_late":"<p><strong>提供名:<br />\n     </strong>サプリメンタルアップデート / オンラインROMフラッシュコンポーネントfor Linux – Apollo 2000 System</p>\n\n<p><strong>リリースバージョンおよび/または日付:</strong><br />\n     1.52<br />\n<br />\n<strong>最新の推奨またはクリティカルバージョン:</strong><br />\n     1.00(C)<br />\n<br />\n<strong>前のファームウェアバージョン:</strong><br />\n     NA<br />\n<br />\n<strong>ファームウェアの関連性：</strong><br />\n     なし\n        <br />\n<br />\n<strong>改善点/新しい機能：</strong></p>\n\n<p>     なし\n        </p>\n\n<p><strong>修正された問題点：</strong></p>\n\n<ul>\n\t<li>HPE Apollo 2000 System SAS Expander FWで、1.51にアップグレードするとHDDのゾーニングテーブルがデフォルトに設定される問題を修正しました。</li>\n</ul>\n\n<p><strong>既知の問題点:</strong><br />\n     なし\n        </p>\n"}],"files":[{"bytes":"5272596","datemodified":"2019-12-04T09:44:04","file_list":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-3bf7ece88e-1.52-1.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-3bf7ece88e-1.52-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-3bf7ece88e-1.52-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-3bf7ece88e-1.52-1.1/CP041660.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-3bf7ece88e-1.52-1.1/firmware-Release-1.52-build-000.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-3bf7ece88e-1.52-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-3bf7ece88e-1.52-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-3bf7ece88e-1.52-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP041660.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP041660.scexe"],"md5sum":"d26b94adf9baa03aae5ce20ca14b8995","name":"firmware-smartarray-3bf7ece88e-1.52-1.1.x86_64.rpm","release":"2020-01-27T00:00:00","revision":"1","sha1sum":"e8fa01b5490130e5064a38e5acfd541c5082d34a","size":"5MB","target_guids":[],"type_of_change":"1","version":"1.52"}],"id":{"product":"5db40f307a93428cb2929e6801c9f6ed","version":"09edc5d1fd7e4156ba544a107192ae2f"},"installation":{"command":"CP038044.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong><em>Updating firmware with rpm installed:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>Install the firmware rpm using the command:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li>\n\t<li>The CP038044.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-3bf7ece88e-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above&nbsp;</li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./ CP038044.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-3bf7ece88e-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><strong><em>Updating firmware without installing the rpm:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-3bf7ece88e-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-3bf7ece88e-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p>\n\n<p><strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li>\n\t<li>Run launch_sum.sh script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p><strong>Additional Information:</strong></p>\n\n<ul>\n\t<li>System AC/DC power cycle is required after a firmware update in order for the update to take effect and for hardware stability to be maintained.</li>\n\t<li>To perform a system AC/DC power cycle: &nbsp;Disconnect the power cords from the server, wait 5 seconds and then reinsert the power cords.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p><strong><em>rpmインストールによるファームウェアのアップデート:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>コマンドを使用して、ファームウェアrpmをインストールします:  <em>rpm -ivh <rpm_filename>。  </em>これは、'/usr/lib/x86_64-linux-gnu' の場所へrpmの内容を解凍します。</li>\n\t<li>CP038044.scexeスクリプトは 'scexe-compat'フォルダーにあります。'firmware-smartarray-3bf7ece88e-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます:\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'の場所で、./ CP038044.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-smartarray-3bf7ece88e-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド: <em>rpm -e <rpm_package_name></em>（'.rpm' 拡張子の付いていないrpmファイル名）を実行します。</li>\n</ul>\n\n<p><strong><em>rpmのインストールなしでのファームウェアのアップデート：</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。 <em>rpm2cpio <rpm_filename>.rpm | cpio -id.  </em>これは、現在のディレクトリの‘usr’フォルダーへrpmの内容を抽出します。</li>\n\t<li>'usr/lib/x86_64-linux-gnu/firmware-smartarray-3bf7ece88e-*'に移動し、ファームウェアをアップデートするために<em>./setup</em>を実行します。'firmware-smartarray-3bf7ece88e-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p><strong><em>追加情報：</em></strong></p>\n\n<p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を解凍するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p> </p>\n\n<p><strong>Smart Update Managerを使用するには Service Pack for ProLiant から以下の手順に従ってください:</strong></p>\n\n<p><strong>オフライン：</strong></p>\n\n<ul>\n\t<li><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant</u></a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/SPP20xxxxx/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>アップデートに必要なファームウェアをSPP20xxxxx/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにあるlaunch_sum.shスクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n\n<p><strong>追加情報：</strong></p>\n\n<ul>\n\t<li>アップデートを有効にして、ハードウェアの安定性を維持するには、ファームウェアのアップデート後にシステムのAC/DC電源を再投入する必要があります。</li>\n\t<li>システムのAC/DC電源の再投入を実行するには、以下の手順に従ってください。 サーバーから電源コードを取り外し、5秒待ってから電源コードを再度取り付けます。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux (x64) - HPE Apollo 2000 System - SAS Expander"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux (x64) - HPE Apollo 2000 System - SASエキスパンダー"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"3239","subdev":"21c2","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c7","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cb","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-03-27T14:28:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Fixed an issue in the HPE Apollo 2000 System SAS Expander FW where the HDD Zoning Table would be set to default after upgrading to 1.51</p>\n\n<p>Please reference Customer Advisory SIK5264.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fixed an issue in the HPE Apollo 2000 System SAS Expander FW where the HDD Zoning Table would be set to default after upgrading to 1.51</p>\n\n<p>Please reference Customer Advisory <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00095304en_us\" style=\"color:#0563c1; text-decoration:underline\">a00095304en_us</a>.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"}],"sw_keys":[{"name":"HP Apollo r2800","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Mellanox CX4LX and CX5 Ethernet NICs for Microsoft Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージは、HPE Mellanox CX4LXおよびCX5 Ethernet NIC for Microsoft Windows Server 2019用のドライバーを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1966248","datemodified":"2021-08-31T14:06:15","file_list":["cp048374.xml","cpqsetup.exe","cp_data.xml","install.xml","mlx5.cat","mlx5.inf","mlx5.sys","mlx5ui.dll","nicdrvr.dll"],"md5sum":"d170f4a7e27800806f3cf713a2bcc8e1","name":"cp048374.exe","release":"2021-08-31T13:50:02","revision":"0","sha1sum":"602ff2e0284ec317223741015f48bdb15205fc35","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"type_of_change":"0","version":"2.70.24728.0"}],"id":{"product":"6d1e58e8f89340958bf7818046e9b7c7","version":"e0fd5db951744f89b3d33c45cd53c3ce"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Mellanox CX4LX and CX5 Driver for Microsoft Windows Server 2019"},{"lang":"ja","x_late":"HPE Mellanox CX4LXおよびCX5ドライバー for Microsoft Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"1018","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101815900282","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1014","subdev":"00c7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1014159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1014","subdev":"00c8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1014159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"1016","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1016159002c1","type":"pci","ven":"15B3"},{"dev":"1016","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1016159002c1","type":"pci","ven":"15B3"},{"dev":"1016","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1016159000d3","type":"pci","ven":"15B3"},{"dev":"1016","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1016159000d4","type":"pci","ven":"15B3"},{"dev":"1018","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101815900246","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T02:04:55","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This product addresses a Windows Stop Error (BSOD) seen when running Mellanox NdStat Utility (mlx5cmd -ndstat) while ND connections was closing.</li>\n\t<li>This product corrects driver loading failures seen due to incorrect INF file.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product correct an issue where mlx5cmd tools reporting of the OS version that a VF is running.</li>\n\t<li>This product correct an issue where incorrect report related to the firmware traces to be logged ( FwTracer) &nbsp;feature on the VF</li>\n\t<li>This product correct an issue where prevented the package downgrade from replacing mlxdevx.dll in the system folder.</li>\n\t<li>This product correct an issue which cause TCP connection to drop&nbsp;</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"mlx5.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the vxn driver for HPE Blade Intel ixn 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2016."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Microsoft Windows Server 2016で動作しているHPE Blade Intel ixt 10 Gigabit Ethernet NIC用のvxnドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1025504","datemodified":"2020-12-02T17:25:23","file_list":["cp045179.xml","cpqsetup.exe","cp_data.xml","install.xml","nicco4.dll","NicCo5.dll","nicdrvr.dll","NicInVXN.dll","vxn65x64.cat","vxn65x64.din","vxn65x64.inf","vxn65x64.sys","vxnmsg.dll"],"md5sum":"96cfa4d8770ef91ae69e90892a2b3574","name":"cp045179.exe","release":"2020-12-02T17:11:09","revision":"0","sha1sum":"78ac09b544a2e68ea4476101a12c6c67a2bf7a2d","size":"0MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec076f9a7c"],"type_of_change":"0","version":"2.1.192.0"}],"id":{"product":"f5e3995830b040538ed866e14afc4c24","version":"fa6e7ba979934b8cabc2bc12f19a5fa1"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Intel vxn Driver for Windows Server 2016"},{"lang":"ja","x_late":"HPE Blade Intel vxnドライバー for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"10ED","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c18d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d2","type":"pci","ven":"8086"},{"dev":"152E","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product is updated to maintain compatibility with updated Windows installation libraries, vxnmsg.dll, nicco5.dll, and nicinvxn.dll.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"vxn65x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under SUSE Linux Enterprise Server 12 SP4 x86_64."},{"lang":"ja","x_late":"この製品は、SUSE Linux Enterprise Server 12 SP4 x86_64下で動作するサポートされたHPE Broadcom NetXtreme-Eアダプターカード用のRoCE（RDMA over Converged Ethernet）ライブラリを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"22819","datemodified":"2021-02-11T00:35:25","file_list":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib64/libbnxt_re-218.0.7.0.so","./usr/lib64/libbnxt_re-rdmav16.so","./usr/lib64/libbnxt_re.so","./usr/share/smartupdate/libbnxt_re/component.xml"],"md5sum":"b9ead5601b07c35eaf3e74dffbbeb92a","name":"libbnxt_re-218.0.7.0-sles12sp4.x86_64.rpm","release":"2021-02-11T00:32:05","revision":"0","sha1sum":"13c1ef59e105372ad73edd4e883b67ed8c3e7f59","size":"22KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"type_of_change":"0","version":"218.0.7.0"}],"id":{"product":"9f0b7493acab4ced83fdf80f7583cdfd","version":"c552a078e5e7474bb80d4e4f8cd3f064"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"text-align:left\">rpm -ivh &lt;bnxt_rooce &gt;.rpm --force [--replacefiles]</p>\n\n<p style=\"text-align:left\">Use --force or --replacefiles options while installing or updating the HPE Broadcom RoCE library which may conflict with inbox library</p>\n"},{"lang":"ja","x_late":"<p style=\"text-align:left\">rpm -ivh <bnxt_rooce >.rpm --force [--replacefiles]</p>\n\n<p style=\"text-align:left\">受信トレイライブラリと競合する可能性があるHPE Broadcom RoCEライブラリのインストールまたはアップデート中に--forceまたは--replacefilesオプションを使用します</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E RoCE Library for SUSE Linux Enterprise Server 12 SP4"},{"lang":"ja","x_late":"SUSE Linux Enterprise Server 12 SP4用HPE Broadcom NetXtreme-E RoCEライブラリ"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>This product corrects an issue which RoCE bond is not getting created automatically after system reboot</li>\n\t<li>This product corrects an issue which errors/performance may degrades after hot plug operation is performed</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product now supports rdma-core v29(rdma user space application)</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"libbnxt_re","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the HPE Apollo 2000 - SAS Expander "},{"lang":"ja","x_late":"このSmartコンポーネントは、HPE Apollo 2000 - SASエキスパンダーのファームウェアを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for VMware ESXi &ndash; Apollo 2000 System -&nbsp;SAS Expander</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.52(A)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;1.52<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;1.52<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li><strong>&nbsp;&nbsp;&nbsp;&nbsp; </strong>Fixed an issue in the HPE Apollo 2000 System SAS Expander FW where the HDD Zoning Table would be set to default after upgrading to 1.51</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"21967457","datemodified":"2020-08-28T03:32:31","file_list":["/CP045347.vmexe","/CP045347.vmexe64","/CP045347.vmfile","/CP045347.xml","/payload.json","/README.txt"],"md5sum":"3d0477976e96b81f4ce8f078426b3063","name":"CP045347.zip","release":"2020-08-28T03:12:05","revision":"0","sha1sum":"1d7f81ef8f7c73d9d036edfb0ba23c947b8aa63e","size":"20MB","target_guids":[],"type_of_change":"1","version":"1.52","vib_list":[]}],"id":{"product":"05a973be660c403e96be2ba6f872a56d","version":"8ad5f719318c4ddaa9df7476d58a4be3"},"installation":{"command":"CP045347.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p>+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++</p>\n\n<p><strong>To use HPE Insight Control for vCenter:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware ESXi - HPE Apollo 2000 System - SAS Expander"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"3239","subdev":"21c2","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cb","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c7","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-09-24T10:54:26","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support for ESXi 7.0</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added support for ESXi 7.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U14","value":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"HP Apollo r2800","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JWZHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a575a4841","Version":"HPD2"},{"DeviceName":"MB012000JWZHB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a575a4842","Version":"HPD2"},{"DeviceName":"MB014000JWZHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a575a4843","Version":"HPD2"},{"DeviceName":"MB016000JWZHE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a575a4845","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"18373109","datemodified":"2021-08-27T14:02:28","file_list":["/CP049051_BUILD_2.data","/CP049051.vmexe","/CP049051.vmexe64","/CP049051.vmfile","/CP049051_VMw.zip","/CP049051.xml","/payload.json","/CP049051_VMw.zip/index.xml","/CP049051_VMw.zip/vendor-index.xml","/CP049051_VMw.zip/metadata.zip","/CP049051_VMw.zip/vib20/CP049051/HPE_bootbank_CP049051_HPD2.2-7.0.0.15843807.vib","/CP049051_VMw.zip/metadata.zip/vendor-index.xml","/CP049051_VMw.zip/metadata.zip/vmware.xml","/CP049051_VMw.zip/metadata.zip/vibs/CP049051-7251617034724169303.xml","/CP049051_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049051_HPD2.2-7.0.0.15843807.xml"],"md5sum":"e7e92ccbe6a695f82b375bf2224e9dfd","name":"CP049051.zip","release":"2021-08-27T13:57:11","revision":"0","sha1sum":"6d3d2d1156b7742a32a8e328d75e900790ed12f2","size":"17MB","target_guids":["4d2340a5-3042-3031-3030-304a575a4841","4d2340a5-3042-3231-3030-304a575a4842","4d2340a5-3042-3431-3030-304a575a4843","4d2340a5-3042-3631-3030-304a575a4845"],"type_of_change":"1","version":"HPD2","vib_list":[{"name":"CP049051","version":"HPD2.2-7.0.0.15843807"}]}],"id":{"product":"628a576c95694de3aab72daab877bb47","version":"a48e68cb8f5e48ccb6a941df8d4e76f4"},"installation":{"command":"CP040517.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB010000JWZHA","target_guid":"4d2340a5-3042-3031-3030-304a575a4841","type":"sas"},{"id":"MB012000JWZHB","target_guid":"4d2340a5-3042-3231-3030-304a575a4842","type":"sas"},{"id":"MB016000JWZHE","target_guid":"4d2340a5-3042-3631-3030-304a575a4845","type":"sas"},{"id":"MB014000JWZHC","target_guid":"4d2340a5-3042-3431-3030-304a575a4843","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-20T10:20:16","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB010000JWZHA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB016000JWZHE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB012000JWZHB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB014000JWZHC","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the SRIOV virtual function drivers for the HPE Blade Intel ixgbe Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Blade Intel ixgbe Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1229883","datemodified":"2021-03-08T20:10:56","file_list":["./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/hp-ixgbevf","./lib/modules/5.3.18-22-default/updates/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/hp-ixgbevf_bl-kmp-default/component.xml"],"md5sum":"7e10600de1fa70c3be7a3603d5327a93","name":"hp-ixgbevf_bl-kmp-default-4.9.3_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-03-08T20:04:10","revision":"0","sha1sum":"982971925273ba8a69c6294818608eb516283686","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec93bdb747"],"type_of_change":"0","version":"4.9.3-1"},{"bytes":"1051883","datemodified":"2021-03-08T20:13:47","file_list":["./lib/modules/4.12.14-195-default","./lib/modules/4.12.14-195-default/updates","./lib/modules/4.12.14-195-default/updates/hp-ixgbevf","./lib/modules/4.12.14-195-default/updates/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/hp-ixgbevf_bl-kmp-default/component.xml"],"md5sum":"50ad8b53edcccb1285ff8d3ed3b04f85","name":"hp-ixgbevf_bl-kmp-default-4.9.3_k4.12.14_195-1.sles15sp1.x86_64.rpm","release":"2021-03-08T20:04:10","revision":"0","sha1sum":"8b114edaae92c28d45a32b0d846154fe71edcd7e","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec93bdb747"],"type_of_change":"0","version":"4.9.3-1"}],"id":{"product":"d05081ab9ef4444a874a5310ab9eff91","version":"d563d7b60897419bb0d727b5ecae0aac"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Intel ixgbevf Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE Blade Intel ixgbevfドライバーfor SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c18d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-03-19T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>These drivers have been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 15 SP2.</p>\n","curr_fixes_x_late":"<p>This product corrects an issue seen when enabling SRIOV, where the VFs have the same, duplicated MAC address.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"hp-ixgbevf_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbevf_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbevf_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbevf_bl-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the iSCSI driver for the HPE Blade Emulex 10/20Gb Server Adapters for Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Windows Server 2019用のHPE Blade Emulex 10/20GbサーバーアダプターのiSCSIドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"905664","datemodified":"2021-07-21T18:22:06","file_list":["be2iscsi.cat","be2iscsi.inf","be2iscsi.sys","bepiscsi.dll","cp049074.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"md5sum":"57f5f9452928c2f50de962a0d4a4e975","name":"cp049074.exe","release":"2021-07-21T18:08:05","revision":"0","sha1sum":"67c939943fa0c98e8d8b64298a74eb22d602b06f","size":"884KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec037c8524"],"type_of_change":"0","version":"12.0.1171.0"}],"id":{"product":"36e4d61e9116490288f4da49e28def20","version":"efd3c86dc97d4670a4c8153e580d1a67"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE iSCSI Driver for Windows Server 2019"},{"lang":"ja","x_late":"HPE Blade Emulex 10/20 GbE iSCSIドライバーfor Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"320"},"supported_devices":[{"dev":"0722","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-03T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports the&nbsp;HPE ProLiant BL660c Gen9 Server.&nbsp;</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"be2iscsi.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6100639","datemodified":"2021-05-18T04:36:58","file_list":["./usr/lib/i386-linux-gnu/firmware-system-u21-2.90_2021_04_29-1.1","./usr/lib/i386-linux-gnu/firmware-system-u21-2.90_2021_04_29-1.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-system-u21-2.90_2021_04_29-1.1/.setup","./usr/lib/i386-linux-gnu/firmware-system-u21-2.90_2021_04_29-1.1/CP047841.xml","./usr/lib/i386-linux-gnu/firmware-system-u21-2.90_2021_04_29-1.1/U21_2.90_04_29_2021.signed.flash","./usr/lib/i386-linux-gnu/firmware-system-u21-2.90_2021_04_29-1.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-system-u21-2.90_2021_04_29-1.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP047841.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP047841.scexe"],"md5sum":"6d0d977eb6291b1d570a8d93677e4139","name":"firmware-system-u21-2.90_2021_04_29-1.1.i386.rpm","release":"2021-05-18T04:27:17","revision":"0","sha1sum":"7000944186468e1b6807fcd6c78887562e495f1a","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021"}],"id":{"product":"f68cbf39561d4281ab240a4897aa0415","version":"73be4b26975c4560b3209ea6954a3836"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HPE ProLiant Agentless Management Service (<strong>AMS</strong>) and HPE SNMP Agents (<strong>SNMP Agents</strong>) are both running.&nbsp; HPE does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager 8.0.0 or later, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、iLOとの通信ができない場合に失敗します。  これは、HPE ProLiant Agentless Management Service (<strong>AMS</strong>)およびHPE SNMPエージェント(<strong>SNMP Agents</strong>)の両方が実行されているときに発生します。  HPEでは、AMSおよびSNMPエージェントを同時に実行させないことを推奨します。  「iLO device not found」エラーが発生した場合、AMSまたはSNMPエージェントを停止させて、再度フラッシュコンポーネントを実行します。<br />\n<br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上のSmart Update Manager 8.0.0以降を使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant XL450 Gen9 (U21) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant XL450 Gen9(U21)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Oracle Linux 7","platform":"Oracle Enterprise Linux","sr":"OEM"},{"major":"6","minor":"0","name":"Oracle Linux 6 (AMD64/EMT64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-05T03:31:19","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"}],"sw_keys":[{"name":"U21","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000800JWZJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3830-304a575a4a50","Version":"HPD4"},{"DeviceName":"VO001600JWZJQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3630-304a575a4a51","Version":"HPD4"},{"DeviceName":"VO003200JWZJR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3230-304a575a4a52","Version":"HPD4"},{"DeviceName":"VO006400JWZJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3630-3430-304a575a4a54","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO000800JWZJP、VO001600JWZJQ、VO003200JWZJRおよびVO006400JWZJT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp; </strong>None</p>\n"}],"files":[{"bytes":"16576186","datemodified":"2021-08-27T13:36:28","file_list":["/CP048454_BUILD_2.data","/CP048454.vmexe","/CP048454.vmexe64","/CP048454.vmfile","/CP048454_VMw.zip","/CP048454.xml","/payload.json","/CP048454_VMw.zip/index.xml","/CP048454_VMw.zip/vendor-index.xml","/CP048454_VMw.zip/metadata.zip","/CP048454_VMw.zip/vib20/CP048454/HPE_bootbank_CP048454_HPD4.2-7.0.0.15843807.vib","/CP048454_VMw.zip/metadata.zip/vendor-index.xml","/CP048454_VMw.zip/metadata.zip/vmware.xml","/CP048454_VMw.zip/metadata.zip/vibs/CP048454--8285572539374706749.xml","/CP048454_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048454_HPD4.2-7.0.0.15843807.xml"],"md5sum":"266e51ea19960813ec2d464af7617e8d","name":"CP048454.zip","release":"2021-08-27T13:29:07","revision":"0","sha1sum":"92e2ae47bb3e13d95051047c9d4686cd8c7fc077","size":"15MB","target_guids":["562340a5-304f-3030-3830-304a575a4a50","562340a5-304f-3130-3630-304a575a4a51","562340a5-304f-3330-3230-304a575a4a52","562340a5-304f-3630-3430-304a575a4a54"],"type_of_change":"1","version":"HPD4","vib_list":[{"name":"CP048454","version":"HPD4.2-7.0.0.15843807"}]}],"id":{"product":"001e7fbaf67f420ebcb746aae6b4aee2","version":"fa3b86e380cb4a2380bb378a90c8e115"},"installation":{"command":"CP040556.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>Additional information to execute VIB file.</strong></p>\n\n<p><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p>             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul>\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p> </p>\n\n<p><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul>\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul>\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT  Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VO000800JWZJP、VO001600JWZJQ、VO003200JWZJRおよびVO006400JWZJTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VO006400JWZJT","target_guid":"562340a5-304f-3630-3430-304a575a4a54","type":"sas"},{"id":"VO003200JWZJR","target_guid":"562340a5-304f-3330-3230-304a575a4a52","type":"sas"},{"id":"VO001600JWZJQ","target_guid":"562340a5-304f-3130-3630-304a575a4a51","type":"sas"},{"id":"VO000800JWZJP","target_guid":"562340a5-304f-3030-3830-304a575a4a50","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T07:34:11","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Modify Drive Vendor Identification String (VID) in Inquiry page from &ldquo;HP&rdquo; to &ldquo;HPE&rdquo;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO000800JWZJP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003200JWZJR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001600JWZJQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO006400JWZJT","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWCBC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRN620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757434243","Version":"HPG6"},{"DeviceName":"MB002000GWCBD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRN620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757434244","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB001000GWCBC and MB002000GWCBD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB001000GWCBC and MB002000GWCBD Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG4</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG4<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"4004984","datemodified":"2021-07-23T19:34:44","file_list":["cp048556.xml","cpqsetup.exe","payload.json","setup.dll","WRN620G6.rel"],"md5sum":"294c024a093b6c2e3f9d6bb560a82f8f","name":"cp048556.exe","release":"2021-07-23T19:27:07","revision":"0","sha1sum":"6941cad46207194e08ceaafea3192d9b20381285","size":"3MB","target_guids":["4d2340a5-3042-3130-3030-304757434243","4d2340a5-3042-3230-3030-304757434244"],"type_of_change":"1","version":"HPG6"}],"id":{"product":"39fa471cea234b3883e794de990ad252","version":"f01d43e61e884cdfa32bd4d4d12c1966"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB001000GWCBC and MB002000GWCBD Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB001000GWCBCおよびMB002000GWCBDドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB001000GWCBC","target_guid":"4d2340a5-3042-3130-3030-304757434243","type":"sata"},{"id":"MB002000GWCBD","target_guid":"4d2340a5-3042-3230-3030-304757434244","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T05:29:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB001000GWCBC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB002000GWCBD","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component contains version 9.4.5.20 of the QLogic Storport driver which provides Mezzanine Fibre Channel Host Bus Adapter driver support for HPE storage arrays."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"1612376","datemodified":"2021-08-27T04:45:55","file_list":["cp048717.xml","cpqsetup.exe","install.xml","ql2300.cat","ql2300.sys","ql2x00.inf","QLOGIC","qlsrvc.exe","QlStorInstaller.dll","readme.txt","release.txt","SysConfig.frm","SysConfig.frm.ja","txtsetup.oem"],"md5sum":"d2412d1fccf25a8841bf44288abebe82","name":"cp048717.exe","release":"2021-08-27T04:43:39","revision":"0","sha1sum":"0db6582e11803af8dc4a4a928678d64e0b54eb19","size":"1MB","target_guids":[],"type_of_change":"1","version":"9.4.5.20"}],"id":{"product":"d1b613ee449f49d2b51f44c18704dea0","version":"e5e282df2f1c4a5b836167f7cfec3af6"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br />\n<br />\nFrom that drive and directory, execute the downloaded file.<br />\n<br />\nClick the &quot;Install&quot; button to proceed with the installation.<br />\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Mezzanine Fibre Channel Adapter Kit for the x64 QLogic Storport Driver for Microsoft Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-18T06:27:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Made improvements to the Fabric Port Identification Number (FPIN) and Universal Storage Area Network (SAN) Congestion Mitigation (USCM) Congestion Management algorithms.</li>\n</ul>\n\n<p>Updated&nbsp;to&nbsp;version&nbsp;9.4.5.20</p>\n","curr_fixes_x_late":"<ul>\n\t<li>Removed the &quot;fwload&quot; registry parameter.</li>\n\t<li>Fixed an unwanted behavior where Link up/down messages were not always logged in the Window System Event log.</li>\n\t<li>Fixed unwanted behavior with the reporting of Fabric Port Identification Number (FPIN) and Universal Storage Area Network (SAN) Congestion Mitigation (USCM) statistics.</li>\n\t<li>Fixed an unwanted behavior where connections to tape drives may fail to recover in the event of &quot;SCSI Check Condition&quot; commands or cable pulls.</li>\n\t<li>Fixed an unwanted behavior where the server may encounter a Blue Screen Of Death (BSOD) 0x0000009f message during shutdown as described in <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00116202en_us\">Advisory: HPE Host Bus Adapters - HPE Platforms Running a Microsoft Windows Server 2016 / 2019 Hyper-V Environment, and Configured With Certain HPE HBAs With the QLogic Storport Driver v9.4.2.20, May Experience a Bug Check 0x9F Event</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"ql2300.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Blade Intel ixgben Adapters running under VMware vSphere 6.5."},{"lang":"ja","x_late":"この製品には、VMware vSphere 6.5上で動作するHPE Blade Intel ixgbenアダプター用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;1.9.11.0.</p>\n"}],"files":[{"bytes":"196126","datemodified":"2021-03-31T14:47:17","file_list":["/cp045171.xml","/VMW-ESX-6.5.0-ixgben-1.9.11.0-offline_bundle-17672460.zip","/VMW-ESX-6.5.0-ixgben-1.9.11.0-offline_bundle-17672460.zip/index.xml","/VMW-ESX-6.5.0-ixgben-1.9.11.0-offline_bundle-17672460.zip/vendor-index.xml","/VMW-ESX-6.5.0-ixgben-1.9.11.0-offline_bundle-17672460.zip/metadata.zip","/VMW-ESX-6.5.0-ixgben-1.9.11.0-offline_bundle-17672460.zip/vib20/ixgben/INT_bootbank_ixgben_1.9.11.0-1OEM.650.0.0.4598673.vib","/VMW-ESX-6.5.0-ixgben-1.9.11.0-offline_bundle-17672460.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.5.0-ixgben-1.9.11.0-offline_bundle-17672460.zip/metadata.zip/vmware.xml","/VMW-ESX-6.5.0-ixgben-1.9.11.0-offline_bundle-17672460.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-ixgben-1.9.11.0.xml","/VMW-ESX-6.5.0-ixgben-1.9.11.0-offline_bundle-17672460.zip/metadata.zip/vibs/ixgben-7460454770853794822.xml"],"md5sum":"cd4f7992329d57e15fbd48810ef87e06","name":"cp045171.zip","release":"2021-03-31T14:45:04","revision":"0","sha1sum":"2251152a56f7aa7724e7e9c4503a403672a977b6","size":"191KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4a9c3d5c"],"type_of_change":"0","version":"2021.04.19","vib_list":[{"name":"ixgben","version":"1.9.11.0-1OEM.650.0.0.4598673"}]}],"id":{"product":"7c150c6f26c6491f9b995cd907650c31","version":"5a83cd2ae373440ab5f6ad38395e5765"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Intel ixgben Driver for VMware vSphere 6.5"},{"lang":"ja","x_late":"HPE Blade Intel ixgbenドライバーfor VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c18d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":"<p>This product corrects a&nbsp;recursion termination condition so that recursion&nbsp;correctly ends in the case of&nbsp; PCIe link down.</p>\n\n<p>This product addresses an issue where the ixgben driver has high CPU overhead&nbsp;when an SFP+ module is absent.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports VMware vSphere 6.5 U3.</p>\n","curr_fixes_x_late":"<p>This product addresses VF issues when calculating, reset PF interface, link state propagation and VLAN trunk scenarios.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"ixgben:1.9.11.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"本產品包含 Red Hat Enterprise Linux 7 x86_64 下執行的 HPE Intel i40e 乙太網路 NIC 驅動程式。"},{"lang":"en","x_late":"This product contains the drivers for the HPE Intel i40e Ethernet NICs running under Red Hat Enterprise Linux 7 x86_64."},{"lang":"ko","x_late":"이 제품에는 Red Hat Enterprise Linux 7 x86_64에서 실행되는 HPE Intel i40e 이더넷 NIC용 드라이버가 포함되어 있습니다."},{"lang":"cn","x_late":"本产品包含适用于在Red Hat Enterprise Linux 7 x86_64下运行的HPE Intel i40e以太网网卡驱动程序。"},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7 x86_64で動作するHPE Intel i40e Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"284341","datemodified":"2021-09-03T08:40:11","file_list":["./etc/depmod.d/hp-i40e.conf","./etc/dracut.conf.d/hp-i40e-oob.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/hp-i40e","./lib/modules/3.10.0-1127.el7.x86_64/extra/hp-i40e/i40e.ko","./usr/share/smartupdate/kmod-hp-i40e/component.xml"],"md5sum":"00ef2d6d406e457ef1b3b5fa7f067dcf","name":"kmod-hp-i40e-2.14.13-1.rhel7u8.x86_64.rpm","release":"2021-09-03T08:27:07","revision":"0","sha1sum":"8c92b8048db559ed6b16a84cb3367fc05f301c47","size":"277KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec243e7654"],"type_of_change":"0","version":"2.14.13-1"},{"bytes":"284332","datemodified":"2021-09-03T08:41:22","file_list":["./etc/depmod.d/hp-i40e.conf","./etc/dracut.conf.d/hp-i40e-oob.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/hp-i40e","./lib/modules/3.10.0-1160.el7.x86_64/extra/hp-i40e/i40e.ko","./usr/share/smartupdate/kmod-hp-i40e/component.xml"],"md5sum":"bfe1735e8a1b8cee781243d0221698c3","name":"kmod-hp-i40e-2.14.13-1.rhel7u9.x86_64.rpm","release":"2021-09-03T08:27:07","revision":"0","sha1sum":"fc98ad8fbf4c91d190c142be6d0ab6809a9afd61","size":"277KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec243e7654"],"type_of_change":"0","version":"2.14.13-1"}],"id":{"product":"3d448885a31a43a9b8495c6b5feb6d8e","version":"73f1b55706c34a64b0712ac4dae5060c"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"},{"lang":"ja","x_late":"<p>インストールのノートについてREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 Red Hat Enterprise Linux 7 x86_64 的 HPE Intel i40e 驅動程式"},{"lang":"en","x_late":"HPE Intel i40e Drivers for Red Hat Enterprise Linux 7 x86_64"},{"lang":"ko","x_late":"Red Hat Enterprise Linux 7 x86_64용 HPE Intel i40e 드라이버"},{"lang":"cn","x_late":"Red Hat Enterprise Linux 7 x86_64版HPE Intel i40e驱动程序"},{"lang":"ja","x_late":"HPE Intel i40eドライバー for Red Hat Enterprise Linux 7 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"},{"dev":"1572","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1572808600a1","type":"pci","ven":"8086"},{"dev":"1572","subdev":"0008","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-157280860008","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"1581","subdev":"00F8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1581159000f8","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-10-02T12:56:38","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product is particular for&nbsp;Red Hat Enterprise Linux 7 Update 8 patched kernel version 3.10.0-1127.10.1 or later.&nbsp;Recommend to use this version 2.14.13(or later) as suggested by Intel TA-256(Technical Advisory).</p>\n","latest_fixes_x_late":"<p>This product corrects an issue where the patched kernel symbol changed on PTP (Precision Time Protocol) module.</p>\n"},{"curr_enhancements_x_late":"<p>This product supports the following new server:</p>\n\n<ul>\n\t<li>HPE ProLiant DL360&nbsp;Gen10 Plus Server</li>\n\t<li>HPE ProLiant DL380&nbsp;Gen10 Plus Server&nbsp;</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"H10","value":"HPE Edgeline e920t Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"H10","value":"HPE Edgeline e920d Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-hp-i40e","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-i40e","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-i40e","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-i40e","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000800KWWFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3830-304b57574645","Version":"HPK3"},{"DeviceName":"MK001600KWWFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3630-304b57574646","Version":"HPK3"},{"DeviceName":"MK003200KWWFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3230-304b57574648","Version":"HPK3"},{"DeviceName":"MK006400KWWFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3630-3430-304b5757464b","Version":"HPK3"},{"DeviceName":"VK000960KWWFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304b5757464c","Version":"HPK3"},{"DeviceName":"VK001920KWWFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304b5757464e","Version":"HPK3"},{"DeviceName":"VK003840KWWFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304b57574650","Version":"HPK3"},{"DeviceName":"VK007680KWWFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-304b57574651","Version":"HPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for VMware ESXi - MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>This FW change resolves a MCTP VDM compliance issue seen by iLO version 2.30.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111061en_us</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"20609710","datemodified":"2021-08-27T06:43:17","file_list":["/CP048467_BUILD_2.data","/CP048467.vmexe","/CP048467.vmexe64","/CP048467.vmfile","/CP048467_VMw.zip","/CP048467.xml","/payload.json","/CP048467_VMw.zip/index.xml","/CP048467_VMw.zip/vendor-index.xml","/CP048467_VMw.zip/metadata.zip","/CP048467_VMw.zip/vib20/CP048467/HPE_bootbank_CP048467_HPK3.2-7.0.0.15843807.vib","/CP048467_VMw.zip/metadata.zip/vendor-index.xml","/CP048467_VMw.zip/metadata.zip/vmware.xml","/CP048467_VMw.zip/metadata.zip/vibs/CP048467--285366709705387401.xml","/CP048467_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048467_HPK3.2-7.0.0.15843807.xml"],"md5sum":"7645bda5f84987998dbabcbe90261181","name":"CP048467.zip","release":"2021-08-27T06:37:41","revision":"0","sha1sum":"c8eaceba6d5b98fd40abc403fe7c733dd7ab0ad4","size":"19MB","target_guids":["4d2340a5-304b-3030-3830-304b57574645","4d2340a5-304b-3130-3630-304b57574646","4d2340a5-304b-3330-3230-304b57574648","4d2340a5-304b-3630-3430-304b5757464b","562340a5-304b-3030-3936-304b5757464c","562340a5-304b-3130-3932-304b5757464e","562340a5-304b-3330-3834-304b57574650","562340a5-304b-3730-3638-304b57574651"],"type_of_change":"2","version":"HPK3","vib_list":[{"name":"CP048467","version":"HPK3.2-7.0.0.15843807"}]}],"id":{"product":"2fa1597649f243c092f040a8ecf90232","version":"a74e0ba192794b24816a4d9330640203"},"installation":{"command":"CP036934.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>HP Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPXXXXXX.vmexe(または)./CPXXXXXX.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi - MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - MK000800KWWFE、MK001600KWWFF、MK003200KWWFH、MK006400KWWFK、 VK000960KWWFL、VK001920KWWFN、 VK003840KWWFPおよびVK007860KWWFQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VK007680KWWFQ","target_guid":"562340a5-304b-3730-3638-304b57574651","type":"nvme"},{"id":"MK006400KWWFK","target_guid":"4d2340a5-304b-3630-3430-304b5757464b","type":"nvme"},{"id":"VK003840KWWFP","target_guid":"562340a5-304b-3330-3834-304b57574650","type":"nvme"},{"id":"MK003200KWWFH","target_guid":"4d2340a5-304b-3330-3230-304b57574648","type":"nvme"},{"id":"VK001920KWWFN","target_guid":"562340a5-304b-3130-3932-304b5757464e","type":"nvme"},{"id":"MK001600KWWFF","target_guid":"4d2340a5-304b-3130-3630-304b57574646","type":"nvme"},{"id":"VK000960KWWFL","target_guid":"562340a5-304b-3030-3936-304b5757464c","type":"nvme"},{"id":"MK00800KWWFE","target_guid":"002340a5-4b4d-3030-3830-304b57574645","type":"nvme"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T13:21:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This FW change resolves a MCTP VDM compliance issue seen by iLO version 2.30.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111061en_us</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This FW change resolves a MCTP VDM compliance issue seen by iLO version 2.30.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111061en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK003840KWWFP","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK001600KWWFF","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK000800KWWFE","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK003200KWWFH","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK007680KWWFQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK001920KWWFN","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK000960KWWFL","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK006400KWWFK","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"8766393","datemodified":"2021-05-17T16:08:40","file_list":["/CP047766.vmexe","/CP047766.vmexe64","/CP047766.vmfile","/CP047766.xml","/README.txt"],"md5sum":"ced57f3053a153c820adc3d83cc14ded","name":"CP047766.zip","release":"2021-05-17T21:05:08","revision":"0","sha1sum":"4495251c13d4f1a081e456cb9382198f308319fe","size":"8MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021","vib_list":[]}],"id":{"product":"4619ed3e4942429da3e6c3f145126229","version":"68398750484c4a9a85e7fbedbc0cd4b2"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component requires that the CRU driver be loaded before the component can run.<br />\nThe minimum CRU version for 5.1 is 5.0.3.9.<br />\nThe minimum CRU version for 5.5 is 5.5.4.1.<br />\nThe minimum CRU version for 6.0 is 6.0.8.<br />\nThe minimum CRU version for 6.5 is 6.5.8.<br />\nThe minimum CRU version for 6.7 is 6.7.10.<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>SPP Offline mode boots a special Linux OS environment, thus the Linux Components are used, not the VMware Components</li>\n</ul>\n\n<p><br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Download the appropriate SPP</li>\n\t<li>Add the component to the SPP</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run SUM</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps to complete the firmware update</li>\n\t<li>Refer to the SPP documentation for detailed instructions at:&nbsp; <a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Component ( CPxxxxxx.zip) in a temporary directory</li>\n\t<li>From the same directory, unzip the Component:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>To perform the standalone installation, execute the command:<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>Follow the directions given by the Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system for the firmware update to take effect</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、実行する前にCRUドライバーがロードされている必要があります。<br />\n5.1の最小CRUバージョンは5.0.3.9です。<br />\n5.5の最小CRUバージョンは5.5.4.1です。<br />\n6.0の最小CRUバージョンは6.0.8です。<br />\n6.5の最小CRUバージョンは6.5.8です。<br />\n6.7の最小CRUバージョンは6.7.10です。<br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMwareコンポーネントではなく、Linuxコンポーネントが用いられます</li>\n</ul>\n\n<p><br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします</li>\n\t<li>SPPにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします</li>\n\t<li>SUMを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います</li>\n\t<li>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>コンポーネント (CPxxxxxx.zip)を一時ディレクトリに置きます</li>\n\t<li>同じディレクトリからコンポーネントをunzipします:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>スタンドアロンのインストールを行うために、次のコマンドを実行します：<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>コンポーネントの指示に従います</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n\t<li>システムを再起動し、ファームウェアのアップデートを有効にします</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware - HPE ProLiant BL460c Gen9/WS460c Gen9 (I36) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for VMware - HPE ProLiant BL460c Gen9/WS460c Gen9 (I36) サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"5","minor":"1","name":"VMware vSphere 5.1","platform":"vmware_esx_server","sr":"OEM"},{"major":"5","minor":"5","name":"VMware vSphere 5.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-29T15:59:26","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>Ver. 2.80_10-16-2020 (B)&nbsp; contains updates to the component packaging and is functionally equivalent to ver. 2.80_10-16-2020.&nbsp; It is not necessary to upgrade with Revision B if a previous component Revision was used to upgrade the system ROM to version 2.80_10-16-2020.</p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"I36","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000480JWDAR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633LD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3438-304a57444152","Version":"HPD8"},{"DeviceName":"VO000960JWDAT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633LD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304a57444154","Version":"HPD8"},{"DeviceName":"VO001920JWDAU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633LD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304a57444155","Version":"HPD8"},{"DeviceName":"VO003840JWDAV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633LD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304a57444156","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VO000480JWDAR, VO000960JWDAT, VO001920JWDAU and VO003840JWDAV"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO000480JWDAR、VO000960JWDAT、VO001920JWDAUおよびVO003840JWDAV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi&nbsp;- VO000480JWDAR, VO000960JWDAT, VO001920JWDAU and VO003840JWDAV&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16695679","datemodified":"2021-08-27T13:08:15","file_list":["/CP048445_BUILD_2.data","/CP048445.vmexe","/CP048445.vmexe64","/CP048445.vmfile","/CP048445_VMw.zip","/CP048445.xml","/payload.json","/CP048445_VMw.zip/index.xml","/CP048445_VMw.zip/vendor-index.xml","/CP048445_VMw.zip/metadata.zip","/CP048445_VMw.zip/vib20/CP048445/HPE_bootbank_CP048445_HPD8.2-7.0.0.15843807.vib","/CP048445_VMw.zip/metadata.zip/vendor-index.xml","/CP048445_VMw.zip/metadata.zip/vmware.xml","/CP048445_VMw.zip/metadata.zip/vibs/CP048445--8748020149411627963.xml","/CP048445_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048445_HPD8.2-7.0.0.15843807.xml"],"md5sum":"4a29de7bb7907d392f8de44d4d8d402d","name":"CP048445.zip","release":"2021-08-27T13:03:11","revision":"0","sha1sum":"1a2b3e4c8c9af3978de1be8d204d4c60249d1725","size":"15MB","target_guids":["562340a5-304f-3030-3438-304a57444152","562340a5-304f-3030-3936-304a57444154","562340a5-304f-3130-3932-304a57444155","562340a5-304f-3330-3834-304a57444156"],"type_of_change":"2","version":"HPD8","vib_list":[{"name":"CP048445","version":"HPD8.2-7.0.0.15843807"}]}],"id":{"product":"bda7d035201d46ffadf44995b633fe12","version":"e898706727e04734811374fee915f4b7"},"installation":{"command":"CP042629.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします。</li>\n\t<li>CPXXXXXX.vmexe(ESXi 6.7 &以前のバージョン)およびCPXXXXXX.vmexe64(ESXi 7.0)は、次のコマンドを使用して実行可能です:</li>\n</ul>\n\n<p>             chmod x CPXXXXXX.vmexe    または    chmod x CPXXXXXX.vmexe64</p>\n\n<ul>\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPXXXXXX.vmexe(または)./CPXXXXXX.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VO000480JWDAR, VO000960JWDAT, VO001920JWDAU and VO003840JWDAV Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VO000480JWDAR、VO000960JWDAT、VO001920JWDAUおよびVO003840JWDAVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VO003840JWDAV","target_guid":"562340a5-304f-3330-3834-304a57444156","type":"sas"},{"id":"VO001920JWDAU","target_guid":"562340a5-304f-3130-3932-304a57444155","type":"sas"},{"id":"VO000960JWDAT","target_guid":"562340a5-304f-3030-3936-304a57444154","type":"sas"},{"id":"VO000480JWDAR","target_guid":"562340a5-304f-3030-3438-304a57444152","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-10T15:10:26","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO003840JWDAV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920JWDAU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000480JWDAR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000960JWDAT","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Intel E1R Gigabit Ethernet NICs running under Microsoft Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Microsoft Windows Server 2019で動作しているHPE Intel E1R Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1074776","datemodified":"2021-08-15T05:41:51","file_list":["cp047044.xml","cpqsetup.exe","cp_data.xml","e1r68x64.cat","e1r68x64.din","e1r68x64.inf","e1r68x64.sys","e1rmsg.dll","install.xml","nicdrvr.dll"],"md5sum":"9b475d94a0517a961a472e0add6c105d","name":"cp047044.exe","release":"2021-08-15T05:24:28","revision":"0","sha1sum":"cffb41264a01b5915e994f327f0d7e0700818d91","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfbeb7312"],"type_of_change":"0","version":"12.18.12.1"}],"id":{"product":"87793aff72a54849a327ce026784372d","version":"a7994178081648348df447829ef20992"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel E1R Driver for Windows Server 2019"},{"lang":"ja","x_late":"HPE Intel E1Rドライバー for Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"3200"},"supported_devices":[{"dev":"1523","subdev":"1989","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1523103c1989","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00FF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1521159000ff","type":"pci","ven":"8086"},{"dev":"1521","subdev":"337F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c337f","type":"pci","ven":"8086"},{"dev":"1521","subdev":"3380","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-1521103c3380","type":"pci","ven":"8086"},{"dev":"1521","subdev":"339E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c339e","type":"pci","ven":"8086"},{"dev":"1521","subdev":"17D1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c17d1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"8157","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c8157","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product contains Windows system update supported improvements.&nbsp;</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product is updated to maintain compatibility with updated Windows installation library NicInE1R.dll and e1rmsg.dll.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"e1r68x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following storage controllers: Smart Array P220i, P222, P420i, P420, P421, P721m, and P822"},{"lang":"cn","x_late":"该x64智能组件为以下存储控制器提供固件： 智能阵列 P220i、P222、P420i、P420、P421、P721m 和 P822"},{"lang":"tw","x_late":"此 x64 智慧型元件提供適用於下列儲存控制器的韌體： Smart Array P220i、P222、P420i、P420、P421、P721m 及 P822"},{"lang":"ko","x_late":"이 x64 스마트 구성 요소는 다음과 같은 스토리지 컨트롤러용 펌웨어를 제공합니다. 스마트 어레이 P220i, P222, P420i, P420, P421, P721m 및 P822"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のストレージコントローラー：SmartアレイP220i, P222, P420i, P420, P421, P721m, およびP822のファームウェアを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for Windows (x64) - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822<br />\n&nbsp;</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 8.32 (C)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 8.32<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 8.32<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Improved Integration with Smart Update Manager</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"7103448","datemodified":"2018-10-03T12:12:19","file_list":["746374726C00.firmware.bin.fw","747365700069443232323073620076312E303200.Baz-102.fuf.fw","cp037741.xml","cpqsetup.exe","d2220sb.bin.fw","setup.dll"],"md5sum":"62ce24341b0d1fe2a8e765b4bad36a05","name":"cp037741.exe","release":"2018-10-03T17:05:03","revision":"0","sha1sum":"ef0014c0f0e663541d06676b0740b97f03a1ef08","size":"6MB","target_guids":[],"type_of_change":"1","version":"8.32"}],"id":{"product":"4998c3a06d0e4ed8ac22e37618080a1f","version":"dc0fa2598792465d8d5eaab1e2679052"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActiveIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Smart Array HPCISSS3 Controller Driver version 100.18.2.64 must not be used for firmware update.  Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfd368f11","ServerModel":["*"],"Target_guids":[],"Type":"NE","Version":"100.18.2.64","description":"HPE ProLiant Smart Array HPCISSS3 Controller Driver version 100.18.2.64 must not be used for firmware update.  Update the driver and reboot before attempting firmware update."}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use HP Smart Update Manager from the </strong><strong><a href=\"http://www.hp.com/go/spp\">Service Pack for ProLiant </a><strong>:</strong></strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\hp\\swpackages</li>\n\t<li>Locate Start.html which is found in the root of the ISO</li>\n\t<li>Open the html file in a supported browser</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p>&nbsp;</p>\n"},{"lang":"cn","x_late":"<p><strong>要从目标服务器上的 Windows 操作系统更新固件：</strong></p>\n\n<ul>\n\t<li>将 Smart Component 存放到一个临时目录中。</li>\n\t<li>双击 Smart Component。</li>\n\t<li>按照 Smart Component 提供的说明执行操作。</li>\n\t<li>如要让更新立即生效，请重新启动系统。</li>\n</ul>\n\n<p><strong>如要通过 HP ProLiant服务包 </strong><strong><a href=\"http://www.hp.com/go/spp\">使用 HP智能升级管理器 </a><strong>：</strong></strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>将更新使用的目标固件放在 \\SPP20xxxxx\\hp\\swpackages 目录中</li>\n\t<li>找到在 ISO 根位置中发现的 Start.html</li>\n\t<li>打开支持的浏览器中的 html 文件</li>\n\t<li>按照屏幕上的说明操作</li>\n</ul>\n\n<p> </p>\n"},{"lang":"tw","x_late":"<p><strong>若要在目標伺服器上從 Windows 作業系統更新韌體：</strong></p>\n\n<ul>\n\t<li>請將智慧型元件置於暫存目錄中。</li>\n\t<li>在智慧型元件上連按兩下。</li>\n\t<li>請依照智慧型元件所提示的相關指示進行。</li>\n\t<li>重新啟動系統，使更新立即生效。</li>\n</ul>\n\n<p><strong>若要從  </strong><strong><a href=\"http://www.hp.com/go/spp\">HP Service Pack for ProLiant (適用於 ProLiant 的服務套件) </a><strong> 中使用 HP Smart Update Manager (HP 智慧型更新管理器)：</strong></strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>將想要更新的韌體放入目錄 \\SPP20xxxxx\\hp\\swpackages</li>\n\t<li>尋找 ISO 的 root 中發現的 Start.html</li>\n\t<li>用支援的瀏覽器開啟 html 檔案</li>\n\t<li>遵循畫面上的說明</li>\n</ul>\n\n<p> </p>\n"},{"lang":"ko","x_late":"<p><strong>대상 서버의 Windows 운영 체제에서 펌웨어를 업데이트하는 방법:</strong></p>\n\n<ul>\n\t<li>스마트 구성 요소를 임시 디렉터리에 저장합니다.</li>\n\t<li>스마트 구성 요소를 더블 클릭합니다.</li>\n\t<li>스마트 구성 요소의 설명에 따라 진행합니다.</li>\n\t<li>업데이트를 바로 적용하려면 시스템을 다시 부팅해야 합니다.</li>\n</ul>\n\n<p><strong>HP Service Pack for ProLiant을 통해  </strong><strong><a href=\"http://www.hp.com/go/spp\">HP Smart Update Manager를 사용하는 방법: </a><strong>:</strong></strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>업데이트하려는 펌웨어를 \\SPP20xxxxx\\hp\\swpackages 디렉터리에 저장합니다.</li>\n\t<li>ISO의 루트에 있는 Start.html을 찾습니다.</li>\n\t<li>지원되는 브라우저에서 html 파일을 엽니다.</li>\n\t<li>화면의 설명에 따라 진행합니다</li>\n</ul>\n\n<p> </p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントをテンポラリディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong><a href=\"http://www.hp.com/go/spp\">Service Pack for ProLiant</a>からHP Smart Update Managerを使用するには、以下の手順に従ってください。</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>ディレクトリ\\SPP20xxxxx\\hp\\swpackagesにアップデートに必要なファームウェアをコピーします。</li>\n\t<li>ISOのルートにあるStart.htmlを選択します。</li>\n\t<li>htmlファイルをサポートされているブラウザーで開きます。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows (x64) - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822"},{"lang":"cn","x_late":"面向 Windows (x64) 的在线 ROM 刷新组件 - 智能阵列 P220i、P222、P420i、P420、P421、P721m 和 P822"},{"lang":"tw","x_late":"適用於 Windows (x64) 的線上 ROM 更新元件 - 智慧型陣列 P220i、P222、P420i、P420、P421、P721m 與 P822"},{"lang":"ko","x_late":"Windows(x64)용 온라인 ROM 플래시 구성 요소 - 스마트 어레이 P220i, P222, P420i, P420, P421, P721m, P822"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows (x64) - SmartアレイP220i、P222、P420i、P420、P421、P721m、およびP822"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_devices":[{"dev":"323b","subdev":"3352","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3351","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3354","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3350","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3355","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3353","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323B","subdev":"3356","subven":"103C","target_guid":"","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"6","minor":"1","name":"Microsoft Windows 7 (64-bit) - All Editions","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows 8.1 (64-bit)","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-10-29T17:12:09","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added HPE Digital Signature</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Improved Integration with Smart Update Manager</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P74","value":"HP ProLiant SL140s Gen8 Server (private)"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"3355103c","sw_key_expectedpath":"firmware"},{"name":"3352103c","sw_key_expectedpath":"firmware"},{"name":"3356103C","sw_key_expectedpath":"firmware"},{"name":"3351103c","sw_key_expectedpath":"firmware"},{"name":"D2220sb","sw_key_expectedpath":"firmware"},{"name":"3350103c","sw_key_expectedpath":"firmware"},{"name":"3354103c","sw_key_expectedpath":"firmware"},{"name":"3353103c","sw_key_expectedpath":"firmware"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK001920KWDUH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304b57445548","Version":"HPK4"},{"DeviceName":"MK001600KWDUN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3630-304b5744554e","Version":"HPK4"},{"DeviceName":"VK000960KWDUF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304b57445546","Version":"HPK4"},{"DeviceName":"MK000800KWDUL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3830-304b5744554c","Version":"HPK4"},{"DeviceName":"VK000480KWDUE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304b57445545","Version":"HPK4"},{"DeviceName":"MK000400KWDUK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3430-304b5744554b","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MK000400KWDUK, VK000480KWDUE, MK000800KWDUL, VK000960KWDUF, MK001600KWDUN and VK001920KWDUH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for Linux (x64) - MK000400KWDUK, VK000480KWDUE, MK000800KWDUL, VK000960KWDUF, MK001600KWDUN&nbsp;and VK001920KWDUH Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>\n"}],"files":[{"bytes":"8150944","datemodified":"2021-07-25T12:43:04","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b45e49679c-HPK4-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-b45e49679c-HPK4-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b45e49679c-HPK4-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b45e49679c-HPK4-6.1/CP048503.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b45e49679c-HPK4-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b45e49679c-HPK4-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b45e49679c-HPK4-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b45e49679c-HPK4-6.1/setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b45e49679c-HPK4-6.1/spannsK4.rel","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048503.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048503.scexe"],"md5sum":"1be7b1ebde1b2745e6ace26775266471","name":"firmware-hdd-b45e49679c-HPK4-6.1.x86_64.rpm","release":"2021-07-25T12:29:06","revision":"0","sha1sum":"63a2ed12d83ba7aa46948b1e822ce82a6fd1dd72","size":"7MB","target_guids":["562340a5-304b-3130-3932-304b57445548","4d2340a5-304b-3130-3630-304b5744554e","562340a5-304b-3030-3936-304b57445546","4d2340a5-304b-3030-3830-304b5744554c","562340a5-304b-3030-3438-304b57445545","4d2340a5-304b-3030-3430-304b5744554b"],"type_of_change":"1","version":"HPK4"}],"id":{"product":"ff420d2a518645bca112d4ae29440c26","version":"e444ab28e4254d73be14cfa7db235fec"},"installation":{"command":"CP040920.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64)  - MK000400KWDUK, VK000480KWDUE, MK000800KWDUL, VK000960KWDUF, MK001600KWDUN and VK001920KWDUH Drives"},{"lang":"ja","x_late":"Linux用オンラインNVMe SSDフラッシュコンポーネント（x64）- MK000400KWDUK、VK000480KWDUE、MK000800KWDUL、VK000960KWDUF、MK001600KWDUN、およびVK001920KWDUHドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MK000400KWDUK","target_guid":"4d2340a5-304b-3030-3430-304b5744554b","type":"nvme"},{"id":"MK000800KWDUL","target_guid":"4d2340a5-304b-3030-3830-304b5744554c","type":"nvme"},{"id":"MK001600KWDUN","target_guid":"4d2340a5-304b-3130-3630-304b5744554e","type":"nvme"},{"id":"VK000480KWDUE","target_guid":"562340a5-304b-3030-3438-304b57445545","type":"nvme"},{"id":"VK000960KWDUF","target_guid":"562340a5-304b-3030-3936-304b57445546","type":"nvme"},{"id":"VK001920KWDUH","target_guid":"562340a5-304b-3130-3932-304b57445548","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T05:45:01","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK000960KWDUF","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK001920KWDUH","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK000800KWDUL","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK001600KWDUN","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK000400KWDUK","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK000480KWDUE","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the drivers for the HPE QLogic NX2 10/20 GbE Multifunction Gigabit Server Adapters for Windows Server 2016, Windows Server 2019 and Windows Server 2022."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This component contains the following drivers:</p>\n\n<ul>\n\t<li>&nbsp;10/20 Gigabit Ethernet VBD Driver 7.13.206.0</li>\n\t<li>&nbsp;iSCSI Offload Driver &nbsp;7.14.17.0</li>\n\t<li>&nbsp;Unified iSCSI Crash Dump Driver 7.13.5.0</li>\n\t<li>&nbsp;Network Adapter NDIS VBD Client 7.13.198.0&nbsp;</li>\n\t<li>&nbsp;FCoE Offload driver &nbsp;7.14.24.0</li>\n\t<li>&nbsp;FCoE Crash Dump Driver 7.13.7.0</li>\n</ul>\n"}],"files":[{"bytes":"3410120","datemodified":"2021-08-11T06:48:43","file_list":["bcm10ginstaller.dll","bnxfcdo.sys","bnxfcdo_release.txt","bxfcoe.cat","bxfcoe.inf","bxfcoe.sys","bxfcoeco.dll","bxfcoe_release.txt","bxnd.cat","bxnd.inf","bxnd60a.sys","bxois.cat","bxois.inf","bxois.sys","bxoisco.dll","bxois_release.txt","cp047060.xml","cpqsetup.exe","cp_data.xml","evbd.cat","evbd.inf","evbda.sys","install.xml","QLogic_slipstream.zip","qnxcdo.sys","qnxcdo_release.txt"],"md5sum":"0f6bfa29d62567b4d8e14c0d31144d19","name":"cp047060.exe","release":"2021-09-02T00:00:00","revision":"1","sha1sum":"3dcf0f53f221e5ccf60407dfd8467aef8349cce2","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec9bc6b74c"],"type_of_change":"1","version":"7.13.206.0"}],"id":{"product":"88920b6128524213bc79e665d9b3a53b","version":"e3da2478d8cf4a528522a0aa7ca98b85"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスク ドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic NX2 10/20 GbE Multifunction Drivers for Windows Server x64 Editions"},{"lang":"ja","x_late":"HPE QLogic NX2 10/20 GbE マルチファンクションドライバーfor Windows Server x64 Editions"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_devices":[{"dev":"168E","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c339d","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c18d3","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1930","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c193a","type":"pci","ven":"14E4"},{"dev":"16A1","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a1159000ec","type":"pci","ven":"1077"},{"dev":"16AF","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c339d","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c18d3","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c193a","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1930","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1931","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c339d","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c193a","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1930","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16ad159000ec","type":"pci","ven":"1077"},{"dev":"16A4","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a4159000ec","type":"pci","ven":"1077"},{"dev":"16AE","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1931","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16af15908148","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ae15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-168e15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1931","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"2231","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c2231","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-10-17T06:05:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports Microsoft Windows Server 2022.</p>\n","latest_fixes_x_late":"<ul>\n\t<li>This product correct an issue where System crash while upgrading with NPAR SRIOV-EP mode enabled.</li>\n\t<li>This product correct an issue where BSOD in Windows NDIS driver while in WS2022 PCS Configuration.<br />\n\t&nbsp;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>This product now supports Microsoft Windows Server 2022.</p>\n","curr_fixes_x_late":"<ul>\n\t<li>This product correct an issue where System crash while upgrading with NPAR SRIOV-EP mode enabled.</li>\n\t<li>This product correct an issue where BSOD in Windows NDIS driver while in WS2022 PCS Configuration.<br />\n\t&nbsp;</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"evbda.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The HPE Insight Management WBEM Providers supply system management data through the Windows Management Instrumentation framework for HPE ProLiant Gen8/Gen9 server platforms and options. The Insight Providers offer industry standard DMTF SMASH profile and SNIA SMI-S profile compliance."},{"lang":"ja","x_late":"HPE Insight Management WBEM Providerは、HPE ProLiant Gen8/Gen9サーバープラットフォームおよびオプション用のWindows Management Instrumentationフレームワークを介してシステム管理データを提供します。Insight Providersは業界標準のDMTF SMASH プロファイルとSNIA SMI-Sプロファイルのコンプライアンスを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"29734528","datemodified":"2021-09-17T13:32:27","file_list":["cp048743.xml","cpqsetup.exe","cp_data.xml","depcheck.dll","hpwbemproviders_x64.msi","hpwmi_cfg.en","hpwmi_cfg.ja","hpwmi_cfg_en.xml","hpwmi_cfg_ja.xml","install.xml","multisetup.dll","mu_visual_cpp_2015_redistributable_update_3_x64_9052538.exe","vc110rtl-x64-release.msi"],"md5sum":"b37e6dae8ecb52ac46e1c31cd5d0426b","name":"cp048743.exe","release":"2021-09-17T13:28:23","revision":"0","sha1sum":"4311cfbb43dce4e865331e37b82f040eb9be391c","size":"28MB","target_guids":[],"type_of_change":"0","version":"11.1.0.0"}],"id":{"product":"5a5d111ea5d342d3a23a115f7e130493","version":"c70cc2ebd7f644deb0381d4388436229"},"installation":{"command":"cpqsetup.exe","command_params":"/optional /verbose_log","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 3/4 Management Controller Driver Package for Windows (Gen 7 or later)","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb0c60beb","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 3/4 Management Controller Driver Package for Windows (Gen 7 or later)"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Advanced System Management Controller Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fd28bc6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Advanced System Management Controller Driver for Windows"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO Advanced and Enhanced System Management Controller Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec156d1f28","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO Advanced and Enhanced System Management Controller Driver for Windows"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 3 Management Controller Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1c3859d4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 3 Management Controller Driver for Windows"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant 100-Series Management Controller Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eceeceee78","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant 100-Series Management Controller Driver for Windows"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 2 Management Controller Driver for Windows (G6 or earlier)","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2c83f673","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 2 Management Controller Driver for Windows (G6 or earlier)"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 3/4 Channel Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 3/4 Channel Interface Driver for Windows"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca9ecb0f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP System Management Homepage for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1b3359b0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP System Management Homepage for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant PCI Hot Plug Controller Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca134477","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant PCI Hot Plug Controller Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Remote Insight Board Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d6a8690","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Remote Insight Board Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Remote Insight Lights-Out II Board Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec043b810e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Remote Insight Lights-Out II Board Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Rack Infrastructure Interface Service for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3c85d0a3","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Rack Infrastructure Interface Service for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC31xx Fast Ethernet NIC Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec0458ccd6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC31xx Fast Ethernet NIC Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Intel Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec29a79e49","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Intel Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Broadcom Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec83d2dd89","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Broadcom Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Broadcom Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec8b37898c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Broadcom Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Broadcom 1Gb Multifunction Driver for Windows Server 2003/2008","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec82a27969","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Broadcom 1Gb Multifunction Driver for Windows Server 2003/2008"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC51xx NetXen Multifunction Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecc2ac73ef","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC51xx NetXen Multifunction Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC52xx NetXen Multifunction Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec7bc999f9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC52xx NetXen Multifunction Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Intel Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6e1a64e9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Intel Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Intel N1E Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec86615221","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Intel N1E Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Broadcom 1Gb Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec09e99f10","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Broadcom 1Gb Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Broadcom 1Gb Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe73cc6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Broadcom 1Gb Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Intel Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec76564025","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Intel Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Broadcom Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec431d2047","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Broadcom Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Broadcom Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbbd7533a","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Broadcom Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Broadcom 1Gb Multifunction Driver for Windows Server 2003/2008 x64 Editions","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd765f4f8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Broadcom 1Gb Multifunction Driver for Windows Server 2003/2008 x64 Editions"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Intel N1E Driver for Windows x64 Editions","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec99544f42","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Intel N1E Driver for Windows x64 Editions"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC51xx NetXen Multifunction Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec10a1b876","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC51xx NetXen Multifunction Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC52xx NetXen Multifunction Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf2c2c1fe","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC52xx NetXen Multifunction Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Intel Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca203699c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Intel Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Intel N1E Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec9814091f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Intel N1E Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Intel N1E Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec013cb3c5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Intel N1E Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Broadcom 1Gb Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4efaf7b6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Broadcom 1Gb Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Broadcom 1Gb Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3f40450a","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Broadcom 1Gb Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Broadcom 10GbE Multifunction Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecba1ae635","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Broadcom 10GbE Multifunction Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Broadcom 10GbE Multifunction Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec9bc6b74c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Broadcom 10GbE Multifunction Driver for Windows"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<ol>\n\t<li>Place the Smart Component in a temporary directory, then double-click it to run.</li>\n\t<li>Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.</li>\n\t<li>Click the &quot;Install&quot; button to perform the installation.</li>\n</ol>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<ol>\n\t<li>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。</li>\n\t<li>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。</li>\n\t<li>[インストール]ボタンをクリックしてインストールを実行します。</li>\n</ol>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Insight Management WBEM Providers for Microsoft Windows x64"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-21T07:56:08","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Server provider\n\t<ul>\n\t\t<li>Fixed product dependency issue</li>\n\t\t<li>Rebrand help information</li>\n\t</ul>\n\t</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Fixed&nbsp;the older WBEM version will still exist&nbsp;in <em>Programs and Features</em> after uninstalling it.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"SPP","value":"HPE Service Pack for ProLiant"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"P88","value":"HP ProLiant ML10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"hpwmiver.dll","sw_key_expectedpath":"%ProgramFiles%\\hpwbem"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXe0HPD7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5748504b","Version":"HPD7"},{"DeviceName":"EH000600JWHPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXe0HPD7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57485048","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EH000900JWHPK and EH000600JWHPH"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EH000900JWHPK および EH000600JWHPH ドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EH000900JWHPK and EH000600JWHPH Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4853612","datemodified":"2021-07-26T17:30:37","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD7-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD7-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD7-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD7-2.1/CP049133.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD7-2.1/TA14SXe0HPD7.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD7-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD7-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD7-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD7-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049133.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049133.scexe"],"md5sum":"f9fffdad5ecfd73b42b497ea8864d239","name":"firmware-hdd-c7df7ceedb-HPD7-2.1.x86_64.rpm","release":"2021-07-26T17:18:04","revision":"0","sha1sum":"3c70e577311d16f085c91433b1c22c7f9d899d4e","size":"4MB","target_guids":["452340a5-3048-3030-3930-304a5748504b","452340a5-3048-3030-3630-304a57485048"],"type_of_change":"1","version":"HPD7"}],"id":{"product":"e3abad55c63d42f3bfc00d8212a8e9d4","version":"6af5a02141ff41d29b6552e85c3dd55d"},"installation":{"command":"CP041670.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP.&lt;nnnnnn&gt;scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EH000900JWHPK and EH000600JWHPH Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux(x64) - EH000900JWHPKおよびEH000600JWHPHドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EH000600JWHPH","target_guid":"452340a5-3048-3030-3630-304a57485048","type":"sas"},{"id":"EH000900JWHPK","target_guid":"452340a5-3048-3030-3930-304a5748504b","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T17:14:15","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This firmware provides a change to the Vendor ID in the VPD page that refers to HP instead of HPE.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH000600JWHPH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000900JWHPK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GWXFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757584646","Version":"HPG2"},{"DeviceName":"MK000960GWXFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757584648","Version":"HPG2"},{"DeviceName":"MK001920GWXFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475758464b","Version":"HPG2"},{"DeviceName":"MK003840GWXFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475758464c","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG1</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG1<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>This&nbsp;FW release deploys an Enhanced Media Scan algorithm that addresses an issue when the host system does not provide enough idle time for drive&rsquo;s Foreground Media Scan to be activated, which is needed to ensure long term drive reliability. It also addresses few minor issues.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"25011932","datemodified":"2021-08-30T07:26:07","file_list":["/CP049299_BUILD_1.data","/CP049299.vmexe","/CP049299.vmexe64","/CP049299.vmfile","/CP049299_VMw.zip","/CP049299.xml","/payload.json","/CP049299_VMw.zip/index.xml","/CP049299_VMw.zip/vendor-index.xml","/CP049299_VMw.zip/metadata.zip","/CP049299_VMw.zip/vib20/CP049299/HPE_bootbank_CP049299_HPG2.1-7.0.0.15843807.vib","/CP049299_VMw.zip/metadata.zip/vendor-index.xml","/CP049299_VMw.zip/metadata.zip/vmware.xml","/CP049299_VMw.zip/metadata.zip/vibs/CP049299-3653185010826679455.xml","/CP049299_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049299_HPG2.1-7.0.0.15843807.xml"],"md5sum":"fa4ebbc475d734290f39f59610594fa4","name":"CP049299.zip","release":"2021-08-30T07:21:38","revision":"0","sha1sum":"7708ed912554f775a45351a35fe6a9984421cbfc","size":"23MB","target_guids":["4d2340a5-304b-3030-3438-304757584646","4d2340a5-304b-3030-3936-304757584648","4d2340a5-304b-3130-3932-30475758464b","4d2340a5-304b-3330-3834-30475758464c"],"type_of_change":"1","version":"HPG2","vib_list":[{"name":"CP049299","version":"HPG2.1-7.0.0.15843807"}]}],"id":{"product":"a6c377914cad4568810f0a24fc0faa52","version":"542beb9061324c8ba9aa4cacc88ff4fd"},"installation":{"command":"CP043281.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MK000480GWXFF、MK000960GWXFH、MK001920GWXFKおよびMK003840GWXFLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MK003840GWXFL","target_guid":"4d2340a5-304b-3330-3834-30475758464c","type":"sata"},{"id":"MK001920GWXFK","target_guid":"4d2340a5-304b-3130-3932-30475758464b","type":"sata"},{"id":"MK000960GWXFH","target_guid":"4d2340a5-304b-3030-3936-304757584648","type":"sata"},{"id":"MK000480GWXFF","target_guid":"4d2340a5-304b-3030-3438-304757584646","type":"sata"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-17T10:41:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>&nbsp;Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This&nbsp;FW release deploys an Enhanced Media Scan algorithm that addresses an issue when the host system does not provide enough idle time for drive&rsquo;s Foreground Media Scan to be activated, which is needed to ensure long term drive reliability. It also addresses few minor issues.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK001920GWXFK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWXFH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK003840GWXFL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWXFF","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCD6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c31543630","Version":"GPK3"},{"DeviceName":"KCD6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c33543230","Version":"GPK3"},{"DeviceName":"KCD6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c36543430","Version":"GPK3"},{"DeviceName":"KCD6XVUL12T8","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c31325438","Version":"GPK3"},{"DeviceName":"KCD6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c38303047","Version":"GPK3"},{"DeviceName":"KCD6XLUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c31543932","Version":"GPK3"},{"DeviceName":"KCD6XLUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c33543834","Version":"GPK3"},{"DeviceName":"KCD6XLUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c37543638","Version":"GPK3"},{"DeviceName":"KCD6XLUL15T3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c31355433","Version":"GPK3"},{"DeviceName":"KCD6XLUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c39363047","Version":"GPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Linux (x64) - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3 Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK3</p>\n\n<p><strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp;</strong> &nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:<br />\n&nbsp; &nbsp; &nbsp; </strong>None</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"5973297","datemodified":"2021-08-16T11:13:39","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK3-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK3-2.1/CP049283.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK3-2.1/TACD6ALLGPK3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK3-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049283.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049283.scexe"],"md5sum":"940fb0268c8915d6a24b54a34dccf016","name":"firmware-hdd-6fc985bd3b-GPK3-2.1.x86_64.rpm","release":"2021-08-16T11:00:06","revision":"0","sha1sum":"dd73092964dd0f6d4a180ec65eee6097fcf228ac","size":"5MB","target_guids":["002340a5-434b-3644-5856-554c31543630","002340a5-434b-3644-5856-554c33543230","002340a5-434b-3644-5856-554c36543430","002340a5-434b-3644-5856-554c31325438","002340a5-434b-3644-5856-554c38303047","002340a5-434b-3644-584c-554c31543932","002340a5-434b-3644-584c-554c33543834","002340a5-434b-3644-584c-554c37543638","002340a5-434b-3644-584c-554c31355433","002340a5-434b-3644-584c-554c39363047"],"type_of_change":"1","version":"GPK3"}],"id":{"product":"2e5a37814cc1401a951db2b5be91b6b3","version":"8874b7c6f603458999b5e771bcfb2e4d"},"installation":{"command":"CP043037.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p><strong>Additional Information:</strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p><strong>追加情報:</strong></p>\n\n<p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/jp/servers/spp_dl\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3  Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - KCD6XVUL800G、KCD6XVUL1T60、KCD6XVUL3T20、KCD6XVUL6T40、KCD6XVUL12T8、KCD6XLUL960G、KCD6XLUL1T92、KCD6XLUL3T84、KCD6XLUL7T68、KCD6XLUL15T3ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"KCD6XLUL7T68","target_guid":"002340a5-434b-3644-584c-554c37543638","type":"nvme"},{"id":"KCD6XVUL6T40","target_guid":"002340a5-434b-3644-5856-554c36543430","type":"nvme"},{"id":"KCD6XVUL1T60","target_guid":"002340a5-434b-3644-5856-554c31543630","type":"nvme"},{"id":"KCD6XVUL800G","target_guid":"002340a5-434b-3644-5856-554c38303047","type":"nvme"},{"id":"KCD6XVUL3T20","target_guid":"002340a5-434b-3644-5856-554c33543230","type":"nvme"},{"id":"KCD6XVUL12T8","target_guid":"002340a5-434b-3644-5856-554c31325438","type":"nvme"},{"id":"KCD6XLUL960G","target_guid":"002340a5-434b-3644-584c-554c39363047","type":"nvme"},{"id":"KCD6XLUL1T92","target_guid":"002340a5-434b-3644-584c-554c31543932","type":"nvme"},{"id":"KCD6XLUL3T84","target_guid":"002340a5-434b-3644-584c-554c33543834","type":"nvme"},{"id":"KCD6XLUL15T3","target_guid":"002340a5-434b-3644-584c-554c31355433","type":"nvme"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-16T10:55:37","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This Firmware release address below&nbsp;fixes and additional features:</p>\n\n<ul>\n\t<li>FW Transfer Fix</li>\n\t<li>Drive Failure Fix</li>\n\t<li>Power Loss Protection</li>\n\t<li>FW Download Fix</li>\n\t<li>Reset Fix</li>\n\t<li>Shutdown fix</li>\n\t<li>PCIe Improvement</li>\n\t<li>Random Write Improvement</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"KCD6XVUL800G","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XLUL7T68","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XLUL3T84","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XLUL960G","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XVUL12T8","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XLUL15T3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XVUL6T40","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XVUL3T20","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XVUL1T60","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XLUL1T92","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900374","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the boot BIOS and firmware of QLogic Mezzanine Fibre Channel host bus adapters."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"8743521","datemodified":"2021-08-25T11:52:05","file_list":["/CP048711_BUILD_2.data","/CP048711.vmexe","/CP048711.vmexe64","/CP048711.vmfile","/CP048711_VMw.zip","/CP048711.xml","/payload.json","/CP048711_VMw.zip/index.xml","/CP048711_VMw.zip/vendor-index.xml","/CP048711_VMw.zip/metadata.zip","/CP048711_VMw.zip/vib20/CP048711/HPE_bootbank_CP048711_2021.09.01.2-6.5.0.4240417.vib","/CP048711_VMw.zip/metadata.zip/vendor-index.xml","/CP048711_VMw.zip/metadata.zip/vmware.xml","/CP048711_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048711_2021.09.01.2-6.5.0.4240417.xml","/CP048711_VMw.zip/metadata.zip/vibs/CP048711--188772565202967673.xml"],"md5sum":"f4c7be809e571bebb7ecaf5e854cb33e","name":"CP048711.zip","release":"2021-08-25T11:46:11","revision":"0","sha1sum":"dd7c676f5e47119cf055b3181c24b6505c9a93ae","size":"8MB","target_guids":[],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"CP048711","version":"2021.09.01.2-6.5.0.4240417"}]}],"id":{"product":"edfb83dcbab8452a855d5cef1fb985cc","version":"ea3dd280f1b44479950936c043ab6113"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated if the ESXi host is Gen9 Server or Enter the IP or DNS address of the iLO of the ESXi host if the Sever is Gen10 and above</li>\n\t<li>Enter the ESXi host/iLO credentials (root or administrator username and password) based on Gen9/Gen10 and above</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for QLogic Mezzanine Fibre Channel Host Bus Adapters for VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-18T06:27:15","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated&nbsp;the Firmware/BIOS/UEFI packages for&nbsp;16 Gb&nbsp;products.</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>MBI</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE QMH2672 16Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>6.04.04</td>\n\t\t\t<td>8.08.232</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.43</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"QLOGIC","sw_key_expectedpath":"firmware:QLOGIC"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000300JWCPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTND7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5743504b","Version":"HPD7"},{"DeviceName":"EH000600JWCPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTND7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5743504c","Version":"HPD7"},{"DeviceName":"EH000900JWCPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTND7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5743504e","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EH000300JWCPK, EH000600JWCPL and EH000900JWCPN"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EH000300JWCPK、EH000600JWCPL、およびEH000900JWCPN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;&nbsp;EH000300JWCPK, EH000600JWCPL&nbsp;and EH000900JWCPN Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"17750356","datemodified":"2021-08-30T06:21:33","file_list":["/CP048286_BUILD_2.data","/CP048286.vmexe","/CP048286.vmexe64","/CP048286.vmfile","/CP048286_VMw.zip","/CP048286.xml","/payload.json","/CP048286_VMw.zip/index.xml","/CP048286_VMw.zip/vendor-index.xml","/CP048286_VMw.zip/metadata.zip","/CP048286_VMw.zip/vib20/CP048286/HPE_bootbank_CP048286_HPD7.2-7.0.0.15843807.vib","/CP048286_VMw.zip/metadata.zip/vendor-index.xml","/CP048286_VMw.zip/metadata.zip/vmware.xml","/CP048286_VMw.zip/metadata.zip/vibs/CP048286-9124546134892661025.xml","/CP048286_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048286_HPD7.2-7.0.0.15843807.xml"],"md5sum":"2a8501d4a382d41a6ec64b1d7ca36f74","name":"CP048286.zip","release":"2021-08-30T06:15:41","revision":"0","sha1sum":"4126fa6a0869a026c12df59767c4bf23fb614a67","size":"16MB","target_guids":["452340a5-3048-3030-3330-304a5743504b","452340a5-3048-3030-3630-304a5743504c","452340a5-3048-3030-3930-304a5743504e"],"type_of_change":"1","version":"HPD7","vib_list":[{"name":"CP048286","version":"HPD7.2-7.0.0.15843807"}]}],"id":{"product":"070f2ccb66ec4478ba85a2e3d9712434","version":"3d210b2ffb594aeb8cfae9a249d9222c"},"installation":{"command":"CP040541.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン：</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例：./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります:rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EH000300JWCPK, EH000600JWCPL and EH000900JWCPN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - EH000300JWCPK、EH000600JWCPL、およびEH000900JWCPNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EH000300JWCPK","target_guid":"452340a5-3048-3030-3330-304a5743504b","type":"sas"},{"id":"EH000600JWCPL","target_guid":"452340a5-3048-3030-3630-304a5743504c","type":"sas"},{"id":"EH000900JWCPN","target_guid":"452340a5-3048-3030-3930-304a5743504e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-03T05:17:35","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH000300JWCPK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000900JWCPN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000600JWCPL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for supported HPE Mellanox adapter cards."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"21305","datemodified":"2021-07-21T05:57:20","file_list":["./etc/depmod.d/kernel-mft-mlnx-mst_pci.conf","./etc/depmod.d/kernel-mft-mlnx-mst_pciconf.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/kernel-mft-mlnx","./lib/modules/4.18.0-240.el8.x86_64/extra/kernel-mft-mlnx/mst_pci.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/kernel-mft-mlnx/mst_pciconf.ko","./usr/share/smartupdate/kmod-kernel-mft-mlnx/component.xml"],"md5sum":"8d6a13784c6bcdfa507ec57691e3c8ce","name":"kmod-kernel-mft-mlnx-4.17.0-1.rhel8u3.x86_64.rpm","release":"2021-07-21T05:45:07","revision":"0","sha1sum":"8a57ca8ff603c24ffd24c9df69a9d0be7faa5fb7","size":"20KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecca403118","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"type_of_change":"1","version":"4.17"},{"bytes":"10003186","datemodified":"2021-07-21T06:00:05","file_list":["./etc/bash_completion.d/mft/mft_base_autocomplete","./etc/bash_completion.d/mft/mft_help_to_completion.py","./etc/init.d/mst","./etc/mft/RPMS/mft","./etc/mft/mft.conf","./etc/mft/mst.conf","./usr/bin/flint","./usr/bin/flint_ext","./usr/bin/mcra","./usr/bin/mdevices_info","./usr/bin/mft_uninstall.sh","./usr/bin/minit","./usr/bin/mlxfwreset","./usr/bin/mlxfwstress","./usr/bin/mlxfwstress_ext","./usr/bin/mlxgearbox","./usr/bin/mlxpci","./usr/bin/mlxprivhost","./usr/bin/mst","./usr/bin/mst_cable","./usr/bin/mst_ib_add","./usr/bin/mstop","./usr/bin/resourcedump","./usr/bin/resourceparse","./usr/bin/stedump","./usr/lib/.build-id","./usr/lib/.build-id/24","./usr/lib/.build-id/24/fbfa259cebc38122d5777b6ba06d2f511631fd","./usr/lib/.build-id/30","./usr/lib/.build-id/30/8cfbe1456bd759c2cd44938b564f6a3b430ee8","./usr/lib/.build-id/77","./usr/lib/.build-id/77/8376ad0d9148eb572ebbcf022a406296ec384e","./usr/lib/.build-id/85","./usr/lib/.build-id/85/b9f1c6dd2bee501c9c71b69ef36ec9b462cbab","./usr/lib/.build-id/ae","./usr/lib/.build-id/ae/ddc4856bbef4477db7eea3e9e40d2ee3861bdd","./usr/lib/.build-id/c8","./usr/lib/.build-id/c8/64d0107db33dee9aa4e32fe13ba9a5a2f3751e","./usr/lib/.build-id/f9","./usr/lib/.build-id/f9/ee267ac48cb4af8a8d21010f1950e07b7c7f2c","./usr/share/man/man1","./usr/share/man/man1/flint.1.gz","./usr/share/man/man1/mcra.1.gz","./usr/share/man/man1/mdevices_info.1.gz","./usr/share/man/man1/minit.1.gz","./usr/share/man/man1/mlxfwreset.1.gz","./usr/share/man/man1/mst.1.gz","./usr/share/man/man1/mstop.1.gz","./usr/share/mft/fw_stress_db","./usr/share/mft/fw_stress_db/stress_types.db","./usr/share/mft/prm_dbs","./usr/share/mft/prm_dbs/hca","./usr/share/mft/prm_dbs/hca/ext","./usr/share/mft/prm_dbs/hca/ext/register_access_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.dat","./usr/share/mft/prm_dbs/switch","./usr/share/mft/prm_dbs/switch/ext","./usr/share/mft/prm_dbs/switch/ext/register_access_table.adb","./usr/share/mft/prm_dbs/switch/ext/register_access_table.dat","./usr/share/smartupdate/mft/component.xml"],"md5sum":"d052de573e6d21ffda03ed6c6e20cfa1","name":"mft-4.17.0-106.rhel8u3.x86_64.rpm","release":"2021-07-21T05:45:07","revision":"0","sha1sum":"7627c71f2e464b1192fb9a12bf5eb2e80a174538","size":"9MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecca403118","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"type_of_change":"1","version":"4.17"}],"id":{"product":"549939a4e5cb4543b7385d514127ff29","version":"2288339daf674890803d342cf8803a42"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\nTo install or upgrade the driver:<br />\n<br />\nIf using kernel version 4.18.0-240.el8.x86_64&nbsp;or any future errata:<br />\n<strong># rpm -Uvh&nbsp;kmod-kernel-mft-mlnx-4.17.0-1.rhel8u3.x86_64.rpm&nbsp;&nbsp;mft-4.17.0-64.rhel8u3.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for Red Hat Enterprise Linux 8 Update 3 (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"101f","subdev":"0012","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30012","type":"pci","ven":"15b3"},{"dev":"101f","subdev":"0007","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30007","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T18:00:43","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","latest_fixes_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n"},{"curr_enhancements_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","curr_fixes_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"kmod-kernel-mft-mlnx","sw_key_expectedpath":"software:rpm"},{"name":"mft","sw_key_expectedpath":"software:rpm"},{"name":"kmod-kernel-mft-mlnx","sw_key_expectedpath":"software:rpm"},{"name":"mft","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWKGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAnAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a574b4755","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB004000JWKGU"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB004000JWKGU"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB004000JWKGU Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD1<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp;</strong>None</p>\n"}],"files":[{"bytes":"4291480","datemodified":"2021-07-23T18:39:07","file_list":["cp048666.xml","cpqsetup.exe","HVLAnAsseFD2.rel","payload.json","setup.dll"],"md5sum":"54f4ef06d5cef500e5f570736d440ed1","name":"cp048666.exe","release":"2021-07-23T18:31:04","revision":"0","sha1sum":"86ab7c9f7499d45200f09f1b47b52b3291dbe205","size":"4MB","target_guids":["4d2340a5-3042-3430-3030-304a574b4755"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"96853662d13b4def814a5c153a747271","version":"3826386021f54d878029e73b1711e4cd"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB004000JWKGU Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB004000JWKGUドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB004000JWKGU","target_guid":"4d2340a5-3042-3430-3030-304a574b4755","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-17T07:18:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB004000JWKGU","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"The HPE Storage Fibre Channel (FC) adapter kit contains version 12.8.334.6 of the Emulex Storport driver for Extended Systems which provides Fibre Channel-Host Bus Adapter (HBA) driver support for HPE Storage RAID Arrays."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"2285704","datemodified":"2021-08-26T07:29:30","file_list":["cp049104.xml","cpqsetup.exe","elxdrvr-fc-12.8.334.6-4.exe","ElxStorInstaller.dll","install.xml","SysConfig.frm","SysConfig.frm.ja"],"md5sum":"e4fb2e07c601a91b0fc0bd2067ab4b2b","name":"cp049104.exe","release":"2021-08-26T07:27:00","revision":"0","sha1sum":"11260f89bfce314c1e5948092439d45ec8b6ac0a","size":"2MB","target_guids":[],"type_of_change":"1","version":"12.8.334.6"}],"id":{"product":"7606adda09de485dbb18a78bdb075302","version":"65487fd4756c472593d161c52b25d400"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation.</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Fibre Channel Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2012R2"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"F100","subven":"10DF","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-23T04:25:27","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to driver version&nbsp;12.8.334.6</p>\n\n<p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p>\n\n<p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p>\n\n<p>The extracted files are located:</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p>\n\n<p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2019</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"elxfc.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 546FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX3Pro-full-rel-2_42_5044-779799-B21_Ax-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C8020","Version":"2.42.5044"},{"DeviceName":"HPE Ethernet 10Gb 2-port 546SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX3Pro-full-rel-2_42_5044-779793-B21_0A-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C801F","Version":"2.42.5044"},{"DeviceName":"HPE Ethernet 100Gb 1-port 842QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_31_1014-874253-B21_Ax-UEFI-14.24.13-FlexBoot-3.6.403.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900246","Version":"16.31.1014"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640 FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4Lx-rel-14_31_1200-817749-B21_Ax-UEFI-14.24.13-FlexBoot-3.6.403.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D3","Version":"14.31.1200"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4Lx-rel-14_31_1200-817753-B21_Ax-UEFI-14.24.13-FlexBoot-3.6.403.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D4","Version":"14.31.1200"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Mellanox Ethernet only adapter firmware on Windows Operating Systems."},{"lang":"ja","x_late":"このパッケージは、Windowsオペレーティングシステム上でHPE Mellanox Ethernetアダプター専用のファームウェアをアップグレードするためのユーティリティとバイナリを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 546SFP+ Adapter (779793-B21)</td>\n\t\t\t<td>2.42.5044</td>\n\t\t\t<td>HP_1200111023</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 546FLR-SFP+ Adapter (779799-B21)</td>\n\t\t\t<td>2.42.5044</td>\n\t\t\t<td>HP_2240110004</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)</td>\n\t\t\t<td>14.31.1200</td>\n\t\t\t<td>HP_2690110034</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</td>\n\t\t\t<td>14.31.1200</td>\n\t\t\t<td>HP_2420110034</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter&nbsp;(874253-B21)</td>\n\t\t\t<td>16.31.1014</td>\n\t\t\t<td>HPE0000000014</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"20430528","datemodified":"2021-09-06T08:35:41","file_list":["cp046585.xml","cpqsetup.exe","fw-ConnectX3Pro-full-rel-2_42_5044-779793-B21_0A-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","fw-ConnectX3Pro-full-rel-2_42_5044-779799-B21_Ax-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","fw-ConnectX4Lx-rel-14_31_1200-817749-B21_Ax-UEFI-14.24.13-FlexBoot-3.6.403.bin","fw-ConnectX4Lx-rel-14_31_1200-817753-B21_Ax-UEFI-14.24.13-FlexBoot-3.6.403.bin","fw-ConnectX5-rel-16_31_1014-874253-B21_Ax-UEFI-14.24.13-FlexBoot-3.6.403.signed.bin","i2cbrdg.dll","installer.dll","libcmdif-1.dll","libgcc_s_seh-1.dll","libmlxfwops-1.dll","libmtcr-1.dll","libreg_access-1.dll","libstdc++-6.dll","libwinpthread-1.dll","libxml2.dll","mdevices.exe","mst64.sys","mstflint.exe","payload.json","perl526.dll","zlib1.dll"],"md5sum":"9b85aa58fca5a6feb66febe318badc66","name":"cp046585.exe","release":"2021-09-06T08:34:15","revision":"0","sha1sum":"d4cb18bc973145d31bb237d42b694072a19c6263","size":"19MB","target_guids":["a6b1a447-382a-5a4f-15B3-1007103C8020","a6b1a447-382a-5a4f-15B3-1007103C801F","a6b1a447-382a-5a4f-15B3-101715900246","a6b1a447-382a-5a4f-15B3-1015159000D3","a6b1a447-382a-5a4f-15B3-1015159000D4"],"type_of_change":"1","version":"1.0.0.15"}],"id":{"product":"00184010ed0a41829836f7c60269273f","version":"f9cfc699f6f44b879e4dbcec36a24ce0"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.\n<p>\n From that drive and directory, execute the downloaded file.</p>\n<p>\n Click the Install button to proceed with the installation.</p>\n"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。\n<p>\n そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p>\n<p>\n インストールボタンをクリックして、インストールを開始してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (Windows x64) for HPE Mellanox Ethernet only adapters"},{"lang":"ja","x_late":"オンラインファームウェアアップグレードユーティリティ(Windows x64) for HPE Mellanox Ethernetアダプター専用"}],"prerequisites":{"required_diskspace":{"size_kb":"27000"},"supported_devices":[{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-18T07:10:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5044 :</strong></p>\n\n<p>&nbsp; &nbsp;779799-B21 (HPE Ethernet 10G 2-port 546FLR-SFP+ Adapter)<br />\n&nbsp; &nbsp;779793-B21 (HPE Ethernet 10G 2-port 546SFP+ Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.31.1200:</strong></p>\n\n<p>&nbsp; &nbsp;817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</p>\n\n<p>&nbsp;&nbsp;&nbsp;817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following device is updated to 16.29.1016:</strong></p>\n\n<p>&nbsp; &nbsp;874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</p>\n\n<p><strong>New Features and Changes included in version 16.31.1200:</strong></p>\n\n<ul>\n\t<li>Added a new NVconfig per Port for a specific Finisar module. This new NVconfig&nbsp;sets the port to work in AN mode and sets the module to No Data Management Engine (DME). This change&nbsp;does not affect the speed logic, only the forward error correction (FEC) logic (FEC override). <strong>Note:</strong>&nbsp;If the port does not&nbsp;come up, switch to Force mode.&nbsp;</li>\n</ul>\n\n<p><strong>New features and changes included &nbsp;in version 16.29.1016:</strong></p>\n\n<ul>\n\t<li>An option to allow applications to build their own QoS tree over the NIC hierarchy by connecting QPs to responder/requestor Queue Groups.</li>\n\t<li>&quot;InfiniBand&quot; properties set to the Network Device Function Redfish object.</li>\n\t<li>HW support for Flow Metering to utilize Advanced Steering Operation (ASO).&nbsp;HW Flow Meter allows higher scale, more accuracy, and better performance compare to the FW Flow Metering.</li>\n\t<li>Trust level for VFs. Once the VF is trusted, it will get a set of trusted capabilities.</li>\n\t<li>2 new Mini CQE formats: Responder Mini CQE With Flow Tag Layout Responder Mini CQE With l3_l4_info Layout</li>\n\t<li>UCX can now enable AR by exposing Out-Of-Ordering bitmask per SL with &quot;ooo_per_sl&quot; field in the HCA_VPORT context. It can be also queried by running the QUERY_HCA_VPORT_CONTEXT&nbsp;command.</li>\n\t<li>Steering DP hash flow groups.</li>\n\t<li>A new counter per vPort that counts the number of packets that reached the Ethernet RQ but cannot fit into the WQE due to their large size. Additionally, we added the option to control if such packet will cause &ldquo;CQE with Error&rdquo; or &ldquo;CQE_MOCK&rdquo;.</li>\n\t<li>PCIe Rx modifications to prevent the adapter cards from disappearing from the system.</li>\n\t<li>ignore_flow_level is now enabled by the TRUST LEVEL access registry.&nbsp;</li>\n\t<li>cq_overrun counter. The counter represents the number of times CQs enter an error state due to overflow that occur when the device tries to post a CQE into a full CQ buffer.</li>\n\t<li>[Beta]&nbsp;Enabled the capability to allow Virtual Functions to send Pause Frames packets.</li>\n\t<li>Enabled 10/25GbE auto-sensing with 3rd party when using 10/25GbE optical cables.</li>\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Fixes&nbsp;included in&nbsp; firmware version 2.42.5044 :</strong></p>\n\n<ul>\n\t<li>An issue that prevented the firmware from detecting a link_down event thus preventing the IB bond interface from going to a failover mode.</li>\n</ul>\n\n<p><strong>Fixes included&nbsp;in firmware version 14.29.1016:</strong></p>\n\n<ul>\n\t<li>Changed the default value of DCQCN&#39;s (Data center- Quantized Congestion Notification) &nbsp;NP parameter min_time_between_cnps to 4 on all devices to support larger scalability of cluster.</li>\n\t<li>An issue that caused&nbsp;packets to drop due to header size issues and/or failing checks. The issue was caused due to a Linux issue that caused&nbsp;VFs to set the wrong header size value in wqe_inline_header_mode input.</li>\n\t<li>When MKEY_BY_NAME was&nbsp;enabled by NVCONFIG and a large number of VFs were configured, VM restart (VF/PF FLR) will take longer than when MKEY_BY_NAME is disabled.</li>\n\t<li>On rare cases, a fatal error related to errors from the PCI transport layer might be reported during FLR.</li>\n\t<li>&nbsp;An issue that caused&nbsp;the device to go to dead IRISC as one of the firmware semaphores could not be released&nbsp;when a speed change or port state change was triggered.&nbsp;</li>\n</ul>\n\n<p><strong>No fixes are included in firmware version 14.31.1200.</strong></p>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5044 :</strong></p>\n\n<p>&nbsp; &nbsp;779799-B21 (HPE Ethernet 10G 2-port 546FLR-SFP+ Adapter)<br />\n&nbsp; &nbsp;779793-B21 (HPE Ethernet 10G 2-port 546SFP+ Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.31.1200:</strong></p>\n\n<p>&nbsp; &nbsp;817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.31.1200:</strong><br />\n&nbsp; &nbsp;817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following device is updated to 16.31.1014:</strong></p>\n\n<p>&nbsp; &nbsp;874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</p>\n\n<p><br />\n<strong>New features and changes in version 14.31.1200:</strong></p>\n\n<ul>\n\t<li>NVconfig per Port for a Specific Finisar Module: Added a new NVconfig per Port for a specific Finisar module. This new NVconfig sets the port to work in AN mode and sets the module to No DME. This change does not affect the speed logic, only the FEC logic (FEC override).<br />\n\t<strong>Note:</strong>&nbsp;If the port does not go up, switch to Force mode.&nbsp;</li>\n</ul>\n\n<p><strong>New features and changes in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>NIC scheduling feature support has been disabled for non-privileged functions.</li>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>Added support for Enabling/Disabling NIC and RDMA (port/partition) via the UEFI HII system settings.<br />\n\t<strong>Note:</strong>&nbsp;Values set in this option only take effect when is Ethernet mode.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Asymmetrical MSIX Configuration:&nbsp;This feature allows the device to be configured with a different number of MSIX<br />\n\tvectors per physical PCI functions.<br />\n\tTo use this feature, please follow these steps:\n\t<ul>\n\t\t<li>​​​​Clear NUM_PF_MSIX_VALID to disable global symmetrical MSIX configuration.</li>\n\t\t<li>Set PF_NUM_PF_MSIX_VALID to enable asymmetrical per Physical Function MSIX configuration.</li>\n\t\t<li>Configure PF_NUM_PF_MSIX per physical PCI function.</li>\n\t</ul>\n\t</li>\n\t<li>Support for RDMA partitioning and RDMA counters in IB mode.</li>\n\t<li>A new bit (&quot;data_in_order&quot;) was added to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.<br />\n\tPages are returned by the driver to the kernel without issuing the MANAGE_PAGES commands to the firmare.</li>\n\t<li>Enabled UID 0 to create resources with UMEM (User Memory).</li>\n\t<li>Receiving and sending native IB packets from/to the software (including all headers) via raw IBL2 QPs.</li>\n\t<li>RX RDMA NIC flow table on an IB port. Now the software can steer native IB packets to raw IB receive queues according to the DLID and<br />\n\tthe DQPN.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Fixes&nbsp;included in&nbsp; firmware version 2.42.5044 :</strong></p>\n\n<ul>\n\t<li>An issue that prevented the firmware from detecting a link_down event thus preventing the IB bond interface from going to a failover mode.</li>\n</ul>\n\n<p><strong>The following issues have been fixed in version 14.31.1200:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n</ul>\n\n<p style=\"margin-left:40px\"><strong>Additional Fixes included in version 14.31.1200:</strong></p>\n\n<ul>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n</ul>\n\n<p><strong>The following issues have been fixed in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>An assert that was caused when trying to open 1024 functions on the device and the maximum number of functions was 1023.</li>\n\t<li>Occasional performance issues related to RC QPs using E2E-credits (not connected to SRQ and doing send/receive traffic) when the ROCE_ACCL tx_window was enabled.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>A rare issue that caused RX pipe to hang.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>An issue that caused the TX queue to get into an unresponsive state when the VF rate limiter was set.</li>\n</ul>\n\n<p style=\"margin-left:40px\"><strong>Additional Fixes included in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>Disabled the CNP counter &ldquo;rp_cnp_ignored &quot; (triggered by OOS (out-of-sequence)) when all ports are IB.</li>\n\t<li>Fixed the TMP421 sensor temperature reporting.</li>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 System"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"","value":"HPE ProLiant SL4500 Chassis"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_NIC","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Blade QLogic NX2 10Gb and 20Gb Multifunction Gigabit Ethernet NICs running under Red Hat Enterprise Linux 7."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7で動作するHPE Blade QLogic NX2 10Gbおよび20GbマルチファンクションGigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"6929836","datemodified":"2021-08-16T17:02:17","file_list":["./etc/depmod.d/netxtreme2.conf","./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/netxtreme2","./lib/modules/3.10.0-1160.el7.x86_64/extra/netxtreme2/bnx2.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/netxtreme2/bnx2fc.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/netxtreme2/bnx2i.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/netxtreme2/bnx2x.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/netxtreme2/cnic.ko","./usr/share/smartupdate/kmod-netxtreme2_bl/component.xml"],"md5sum":"59301d9bfaac866bb704a063dd6ca537","name":"kmod-netxtreme2_bl-7.14.80-5.rhel7u9.x86_64.rpm","release":"2021-08-16T16:39:27","revision":"0","sha1sum":"537354133b7824b04c69f428770daa42aedb8557","size":"6MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec63a13bba"],"type_of_change":"0","version":"7.14.80-5"},{"bytes":"6927796","datemodified":"2021-08-16T17:05:18","file_list":["./etc/depmod.d/netxtreme2.conf","./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/netxtreme2","./lib/modules/3.10.0-1127.el7.x86_64/extra/netxtreme2/bnx2.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/netxtreme2/bnx2fc.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/netxtreme2/bnx2i.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/netxtreme2/bnx2x.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/netxtreme2/cnic.ko","./usr/share/smartupdate/kmod-netxtreme2_bl/component.xml"],"md5sum":"1ebb033a6754e233c0a0a89bb51da8a6","name":"kmod-netxtreme2_bl-7.14.80-5.rhel7u8.x86_64.rpm","release":"2021-08-16T16:39:27","revision":"0","sha1sum":"7e1cee13ed0a0aa3d094d020e91507b8a5081a02","size":"6MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec63a13bba"],"type_of_change":"0","version":"7.14.80-5"}],"id":{"product":"690ed2c76a80449da0cbf178bbdf3cd5","version":"a9d334fd35d64c52b833a58b6cf78336"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 7"},{"lang":"ja","x_late":"HPE Blade QLogic NX2 10/20 GbEマルチファンクションドライバーfor Red Hat Enterprise Linux 7"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"168E","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1933","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c22fa","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1917","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1916","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1933","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1916","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1917","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c22fa","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1933","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c22fa","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1916","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1917","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-09-03T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 7, Updates 8 and 9.</p>\n","latest_fixes_x_late":"<p>This product corrects an issue where the driver fails to load in NPAR mode when RoCE Data Center Quantized Congestion Notification (DCQCN) is enabled.<br />\nThis product addresses a system crash seen when unloading and reloading the RoCE driver only.<br />\nThis product addresses a system crash seen during multiple reboots of virtual machines using VFs and RDMA.<br />\nThis product addresses a system crash seen when injecting a fw_assert on a NIC PF.<br />\nThis product corrects an issue where a system fails to shutdown after reboots in iSCSI BFS.</p>\n"},{"curr_enhancements_x_late":"<p>This product is updated to maintain compatibility with firmware version 1.5.x.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"kmod-netxtreme2_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-netxtreme2_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-netxtreme2_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-netxtreme2_bl","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for supported HPE Mellanox adapter cards."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"20973","datemodified":"2021-07-21T05:56:11","file_list":["./etc/depmod.d/kernel-mft-mlnx-mst_pci.conf","./etc/depmod.d/kernel-mft-mlnx-mst_pciconf.conf","./lib/modules/4.18.0-305.el8.x86_64","./lib/modules/4.18.0-305.el8.x86_64/extra","./lib/modules/4.18.0-305.el8.x86_64/extra/kernel-mft-mlnx","./lib/modules/4.18.0-305.el8.x86_64/extra/kernel-mft-mlnx/mst_pci.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/kernel-mft-mlnx/mst_pciconf.ko","./usr/share/smartupdate/kmod-kernel-mft-mlnx/component.xml"],"md5sum":"ed2c5d8759941871b4671b2ac6824d1f","name":"kmod-kernel-mft-mlnx-4.17.0-1.rhel8u4.x86_64.rpm","release":"2021-07-21T05:46:09","revision":"0","sha1sum":"f2449c39afd79a074012787b96afb9cb9dc77d40","size":"20KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecca403118","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"type_of_change":"1","version":"4.17"},{"bytes":"10003189","datemodified":"2021-07-21T05:54:55","file_list":["./etc/bash_completion.d/mft/mft_base_autocomplete","./etc/bash_completion.d/mft/mft_help_to_completion.py","./etc/init.d/mst","./etc/mft/RPMS/mft","./etc/mft/mft.conf","./etc/mft/mst.conf","./usr/bin/flint","./usr/bin/flint_ext","./usr/bin/mcra","./usr/bin/mdevices_info","./usr/bin/mft_uninstall.sh","./usr/bin/minit","./usr/bin/mlxfwreset","./usr/bin/mlxfwstress","./usr/bin/mlxfwstress_ext","./usr/bin/mlxgearbox","./usr/bin/mlxpci","./usr/bin/mlxprivhost","./usr/bin/mst","./usr/bin/mst_cable","./usr/bin/mst_ib_add","./usr/bin/mstop","./usr/bin/resourcedump","./usr/bin/resourceparse","./usr/bin/stedump","./usr/lib/.build-id","./usr/lib/.build-id/24","./usr/lib/.build-id/24/fbfa259cebc38122d5777b6ba06d2f511631fd","./usr/lib/.build-id/30","./usr/lib/.build-id/30/8cfbe1456bd759c2cd44938b564f6a3b430ee8","./usr/lib/.build-id/77","./usr/lib/.build-id/77/8376ad0d9148eb572ebbcf022a406296ec384e","./usr/lib/.build-id/85","./usr/lib/.build-id/85/b9f1c6dd2bee501c9c71b69ef36ec9b462cbab","./usr/lib/.build-id/ae","./usr/lib/.build-id/ae/ddc4856bbef4477db7eea3e9e40d2ee3861bdd","./usr/lib/.build-id/c8","./usr/lib/.build-id/c8/64d0107db33dee9aa4e32fe13ba9a5a2f3751e","./usr/lib/.build-id/f9","./usr/lib/.build-id/f9/ee267ac48cb4af8a8d21010f1950e07b7c7f2c","./usr/share/man/man1","./usr/share/man/man1/flint.1.gz","./usr/share/man/man1/mcra.1.gz","./usr/share/man/man1/mdevices_info.1.gz","./usr/share/man/man1/minit.1.gz","./usr/share/man/man1/mlxfwreset.1.gz","./usr/share/man/man1/mst.1.gz","./usr/share/man/man1/mstop.1.gz","./usr/share/mft/fw_stress_db","./usr/share/mft/fw_stress_db/stress_types.db","./usr/share/mft/prm_dbs","./usr/share/mft/prm_dbs/hca","./usr/share/mft/prm_dbs/hca/ext","./usr/share/mft/prm_dbs/hca/ext/register_access_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.dat","./usr/share/mft/prm_dbs/switch","./usr/share/mft/prm_dbs/switch/ext","./usr/share/mft/prm_dbs/switch/ext/register_access_table.adb","./usr/share/mft/prm_dbs/switch/ext/register_access_table.dat","./usr/share/smartupdate/mft/component.xml"],"md5sum":"a933ddea5e418776638f4a48176ebac5","name":"mft-4.17.0-106.rhel8u4.x86_64.rpm","release":"2021-07-21T05:46:09","revision":"0","sha1sum":"d45db44c2bff4892ecabc7fde068cb3107685253","size":"9MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecca403118","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"type_of_change":"1","version":"4.17"}],"id":{"product":"deefa9a645fa441b8de838a7e800e6dd","version":"754efe0903ce4196a59a7df4fc967b92"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\nTo install or upgrade the driver:<br />\n<br />\nIf using kernel version 4.18.0-305.el8.x86_64&nbsp;or any future errata:<br />\n<strong># rpm -Uvh&nbsp;kmod-kernel-mft-mlnx-4.17.0-1.rhel8u4.x86_64.rpm&nbsp;&nbsp;mft-4.17.0-64.rhel8u4.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for Red Hat Enterprise Linux 8 Update 4 (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"101f","subdev":"0012","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30012","type":"pci","ven":"15b3"},{"dev":"101f","subdev":"0007","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30007","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T18:00:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","curr_fixes_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"kmod-kernel-mft-mlnx","sw_key_expectedpath":"software:rpm"},{"name":"mft","sw_key_expectedpath":"software:rpm"},{"name":"kmod-kernel-mft-mlnx","sw_key_expectedpath":"software:rpm"},{"name":"mft","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400PXDBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AL4HPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-305058444251","Version":"HPD1"},{"DeviceName":"EO000800PXDCK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AL4HPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-30505844434b","Version":"HPD1"},{"DeviceName":"EO001600PXDCH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AL4HPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-305058444348","Version":"HPD1"},{"DeviceName":"MO000800PXDBP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AL4HPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-305058444250","Version":"HPD1"},{"DeviceName":"MO001600PXDCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AL4HPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-305058444343","Version":"HPD1"},{"DeviceName":"MO003200PXDCD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AL4HPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-305058444344","Version":"HPD1"},{"DeviceName":"MO006400PXDCE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AL4HPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-305058444345","Version":"HPD1"},{"DeviceName":"VO000960PXDBN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AL4HPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-30505844424e","Version":"HPD1"},{"DeviceName":"VO001920PXDBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AL4HPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-305058444252","Version":"HPD1"},{"DeviceName":"VO003840PXDBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AL4HPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-305058444254","Version":"HPD1"},{"DeviceName":"VO007680PXDBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AL4HPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-305058444255","Version":"HPD1"},{"DeviceName":"VO015300PXDBV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AL4HPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3330-305058444256","Version":"HPD1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3759904","datemodified":"2021-07-27T16:37:21","file_list":["cp049162.xml","cpqsetup.exe","payload.json","setup.dll","TAPM6AL4HPD1.rel"],"md5sum":"9d12f165f82ab52107fe3163f7197c47","name":"cp049162.exe","release":"2021-07-27T16:29:04","revision":"0","sha1sum":"edfc9a2c009cda60ea2b374a2c8a64a51ef4cdfa","size":"3MB","target_guids":["452340a5-304f-3030-3430-305058444251","452340a5-304f-3030-3830-30505844434b","452340a5-304f-3130-3630-305058444348","4d2340a5-304f-3030-3830-305058444250","4d2340a5-304f-3130-3630-305058444343","4d2340a5-304f-3330-3230-305058444344","4d2340a5-304f-3630-3430-305058444345","562340a5-304f-3030-3936-30505844424e","562340a5-304f-3130-3932-305058444252","562340a5-304f-3330-3834-305058444254","562340a5-304f-3730-3638-305058444255","562340a5-304f-3531-3330-305058444256"],"type_of_change":"1","version":"HPD1"}],"id":{"product":"139d2679780d42b2a020c2a6176ac11b","version":"c13c80e7737249bda9a39dceb03e6d88"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration-line: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV  Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EO000800PXDCK","target_guid":"452340a5-304f-3030-3830-30505844434b","type":"sas"},{"id":"MO000800PXDBP","target_guid":"4d2340a5-304f-3030-3830-305058444250","type":"sas"},{"id":"EO000400PXDBQ","target_guid":"452340a5-304f-3030-3430-305058444251","type":"sas"},{"id":"EO001600PXDCH","target_guid":"452340a5-304f-3130-3630-305058444348","type":"sas"},{"id":"MO001600PXDCC","target_guid":"4d2340a5-304f-3130-3630-305058444343","type":"sas"},{"id":"MO006400PXDCE","target_guid":"4d2340a5-304f-3630-3430-305058444345","type":"sas"},{"id":"VO007680PXDBU","target_guid":"562340a5-304f-3730-3638-305058444255","type":"sas"},{"id":"VO001920PXDBR","target_guid":"562340a5-304f-3130-3932-305058444252","type":"sas"},{"id":"VO015300PXDBV","target_guid":"562340a5-304f-3531-3330-305058444256","type":"sas"},{"id":"MO003200PXDCD","target_guid":"4d2340a5-304f-3330-3230-305058444344","type":"sas"},{"id":"VO000960PXDBN","target_guid":"562340a5-304f-3030-3936-30505844424e","type":"sas"},{"id":"VO003840PXDBT","target_guid":"562340a5-304f-3330-3834-305058444254","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-27T16:25:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO007680PXDBU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO001600PXDCH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920PXDBR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000800PXDCK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200PXDCD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003840PXDBT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO015300PXDBV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000960PXDBN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600PXDCC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000400PXDBQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO006400PXDCE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800PXDBP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWTBK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304a5754424b","Version":"HPD9"},{"DeviceName":"VO001920JWTBL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304a5754424c","Version":"HPD9"},{"DeviceName":"VO003840JWTBN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304a5754424e","Version":"HPD9"},{"DeviceName":"VO007680JWTBP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304a57544250","Version":"HPD9"},{"DeviceName":"MO000400JWTBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57544251","Version":"HPD9"},{"DeviceName":"MO000800JWTBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57544252","Version":"HPD9"},{"DeviceName":"MO001600JWTBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57544254","Version":"HPD9"},{"DeviceName":"MO003200JWTBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57544255","Version":"HPD9"},{"DeviceName":"MO006400JWTCD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a57544344","Version":"HPD9"},{"DeviceName":"EO000400JWTBV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57544256","Version":"HPD9"},{"DeviceName":"EO000800JWTCA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57544341","Version":"HPD9"},{"DeviceName":"EO001600JWTCB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57544342","Version":"HPD9"},{"DeviceName":"EO003200JWTCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3330-3230-304a57544343","Version":"HPD9"},{"DeviceName":"MO001920JWWWV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a57575756","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA, EO001600JWTCB, EO003200JWTCC and MO001920JWWWV "},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO000960JWTBK、VO001920JWTBL、VO003840JWTBN、VO007680JWTBP、MO000400JWTBQ、MO000800JWTBR、MO001600JWTBT、MO003200JWTBU、MO006400JWTCD、EO000400JWTBV、EO000800JWTCA、EO001600JWTCB、EO003200JWTCC およびMO001920JWWWV "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA, EO001600JWTCB, EO003200JWTCC and MO001920JWWWV Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"2990568","datemodified":"2021-07-26T20:08:06","file_list":["cp049146.xml","cpqsetup.exe","payload.json","setup.dll","TAPM5ALLHPD9.rel"],"md5sum":"2882bd8c4dbbb0e6ff43f0c4eea60a23","name":"cp049146.exe","release":"2021-07-26T20:00:05","revision":"0","sha1sum":"19d8185d8b789b1b16cd4ef1c99a3ed88ac14d4c","size":"2MB","target_guids":["562340a5-304f-3030-3936-304a5754424b","562340a5-304f-3130-3932-304a5754424c","562340a5-304f-3330-3834-304a5754424e","562340a5-304f-3730-3638-304a57544250","4d2340a5-304f-3030-3430-304a57544251","4d2340a5-304f-3030-3830-304a57544252","4d2340a5-304f-3130-3630-304a57544254","4d2340a5-304f-3330-3230-304a57544255","4d2340a5-304f-3630-3430-304a57544344","452340a5-304f-3030-3430-304a57544256","452340a5-304f-3030-3830-304a57544341","452340a5-304f-3130-3630-304a57544342","452340a5-304f-3330-3230-304a57544343","4d2340a5-304f-3130-3932-304a57575756"],"type_of_change":"1","version":"HPD9"}],"id":{"product":"9141b4ee76c74b70a4eb2f021bfa217f","version":"5f88613e063c4dff95201f419e453e8f"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA and EO001600JWTCB Drives"},{"lang":"ja","x_late":"オンライン HDD/SSDフラッシュコンポーネントfor Windows (x64) - VO000960JWTBK、VO001920JWTBL、VO003840JWTBN、VO007680JWTBP、MO000400JWTBQ、MO000800JWTBR、MO001600JWTBT、MO003200JWTBU、MO006400JWTCD、EO000400JWTBV、EO000800JWTCA、EO001600JWTCB ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VO007680JWTBP","target_guid":"562340a5-304f-3730-3638-304a57544250","type":"sas"},{"id":"MO006400JWTCD","target_guid":"4d2340a5-304f-3630-3430-304a57544344","type":"sas"},{"id":"VO003840JWTBN","target_guid":"562340a5-304f-3330-3834-304a5754424e","type":"sas"},{"id":"MO003200JWTBU","target_guid":"4d2340a5-304f-3330-3230-304a57544255","type":"sas"},{"id":"EO003200JWTCC","target_guid":"452340a5-304f-3330-3230-304a57544343","type":"sas"},{"id":"VO001920JWTBL","target_guid":"562340a5-304f-3130-3932-304a5754424c","type":"sas"},{"id":"MO001600JWTBT","target_guid":"4d2340a5-304f-3130-3630-304a57544254","type":"sas"},{"id":"EO001600JWTCB","target_guid":"452340a5-304f-3130-3630-304a57544342","type":"sas"},{"id":"VO000960JWTBK","target_guid":"562340a5-304f-3030-3936-304a5754424b","type":"sas"},{"id":"MO000800JWTBR","target_guid":"4d2340a5-304f-3030-3830-304a57544252","type":"sas"},{"id":"EO000800JWTCA","target_guid":"452340a5-304f-3030-3830-304a57544341","type":"sas"},{"id":"MO000400JWTBQ","target_guid":"4d2340a5-304f-3030-3430-304a57544251","type":"sas"},{"id":"EO000400JWTBV","target_guid":"452340a5-304f-3030-3430-304a57544256","type":"sas"},{"id":"MO001920JWWWV","target_guid":"4d2340a5-304f-3130-3932-304a57575756","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T19:56:36","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Change Vendor Identification Field (VID data) from &quot;HP&quot; to &quot;HPE&quot;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EO000400JWTBV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001920JWWWV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920JWTBL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600JWTBT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO001600JWTCB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000800JWTCA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800JWTBR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000960JWTBK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO007680JWTBP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200JWTBU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO006400JWTCD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000400JWTBQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003840JWTBN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO003200JWTCC","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"tw","x_late":"HPE SNMP 代理程式 (hp-snmp-agents) 彙集了多個以 SNMP 通訊協定為基礎的代理程式及工具，可讓您透過 SNMP 來監控風扇、電源供應器、溫度感應器以及其他管理事件。另外，提供下列項目： 基礎及伺服器代理程式、儲存子系統代理程式、網路子系統代理程式、SNMP 動態載入模組及網路支援應用程式。"},{"lang":"en","x_late":"The HPE SNMP Agents (hp-snmp-agents) is a collection  of SNMP  protocol based agents  and tools which enables monitoring of fans, power supplies, temperature sensors and other management events via SNMP. It also provides the following: Foundation and Server agents, Storage Subsystem agents, Network Subsystem agents, the SNMP Dynamically Loaded Module, and the web support applications."},{"lang":"ko","x_late":"HPE SNMP 에이전트(hp-snmp-agents)는 SNMP를 통해 팬, 전원 공급 장치, 온도 센서 및 기타 관리 이벤트를 모니터링하게 하는 SNMP 프로토콜 기반 에이전트 및 도구 모음입니다. 이 외에도 파운데이션 및 서버 에이전트, 스토리지 하위 시스템 에이전트, 네트워크 하위 시스템 에이전트, SNMP 동적 로드 모듈 및 웹 지원 응용 프로그램 등을 제공합니다."},{"lang":"cn","x_late":"HPE SNMP Agents (hp-snmp-agents) 是一系列基于 SNMP 协议的代理程序和工具，能够通过 SNMP 监控风扇、电源、温度传感器和其他管理事件。它还提供了以下程序： 基础架构和服务器代理程序、存储子系统代理程序、网络子系统代理程序、SNMP 动态加载模块和 Web 支持应用程序。"},{"lang":"ja","x_late":"HPE SNMPエージェント（hp-snmp-agents）は、SNMPプロトコル ベースのエージェント、およびファンの監視、電源、温度センサー、およびその他管理イベントをSNMP経由で行うツールを集めたものです。 また、次の機能も提供します。 基本およびサーバーエージェント、ストレージ サブシステムエージェント、ネットワークサブシステムエージェント、SNMP Dynamically Loaded Module、およびWebサポート アプリケーション。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[{"lang":"en","x_late":null}],"files":[{"bytes":"1340580","datemodified":"2021-08-25T03:47:18","file_list":["./etc/hp-snmp-agents.conf","./etc/logrotate.d/hp-snmp-agents","./opt/hp/hp-snmp-agents","./opt/hp/hp-snmp-agents/addons","./opt/hp/hp-snmp-agents/cma.conf","./opt/hp/hp-snmp-agents/hp-snmp-agents.license","./opt/hp/hp-snmp-agents/hp-snmp-agents.manifest","./opt/hp/hp-snmp-agents/hp-snmp-agents.rebuild.spec","./opt/hp/hp-snmp-agents/hprpm.xpm","./opt/hp/hp-snmp-agents/mibs","./opt/hp/hp-snmp-agents/mibs/cmafdtnobjects.conf","./opt/hp/hp-snmp-agents/mibs/cmanicobjects.conf","./opt/hp/hp-snmp-agents/mibs/cmaobjects.conf","./opt/hp/hp-snmp-agents/mibs/cmaobjects.mibdef","./opt/hp/hp-snmp-agents/mibs/cmaobjects.mibver","./opt/hp/hp-snmp-agents/mibs/cmaobjects.regmib","./opt/hp/hp-snmp-agents/mibs/cmastorobjects.conf","./opt/hp/hp-snmp-agents/mibs/cmasvrobjects.conf","./opt/hp/hp-snmp-agents/nic","./opt/hp/hp-snmp-agents/nic/bin","./opt/hp/hp-snmp-agents/nic/bin/cmanicd","./opt/hp/hp-snmp-agents/nic/bin/hpetfe","./opt/hp/hp-snmp-agents/nic/etc","./opt/hp/hp-snmp-agents/nic/etc/HPcmanic.pp","./opt/hp/hp-snmp-agents/nic/etc/cmanic","./opt/hp/hp-snmp-agents/nic/etc/cmanicd","./opt/hp/hp-snmp-agents/rebuild","./opt/hp/hp-snmp-agents/server","./opt/hp/hp-snmp-agents/server/bin","./opt/hp/hp-snmp-agents/server/bin/cmahealthd","./opt/hp/hp-snmp-agents/server/bin/cmahostd","./opt/hp/hp-snmp-agents/server/bin/cmapeerd","./opt/hp/hp-snmp-agents/server/bin/cmaperfd","./opt/hp/hp-snmp-agents/server/bin/cmasm2d","./opt/hp/hp-snmp-agents/server/bin/cmastdeqd","./opt/hp/hp-snmp-agents/server/bin/cmathreshd","./opt/hp/hp-snmp-agents/server/bin/distro-id.sh","./opt/hp/hp-snmp-agents/server/etc","./opt/hp/hp-snmp-agents/server/etc/cmad","./opt/hp/hp-snmp-agents/server/etc/cmahealthd","./opt/hp/hp-snmp-agents/server/etc/cmahostd","./opt/hp/hp-snmp-agents/server/etc/cmapeerd","./opt/hp/hp-snmp-agents/server/etc/cmaperfd","./opt/hp/hp-snmp-agents/server/etc/cmarackd","./opt/hp/hp-snmp-agents/server/etc/cmasm2d","./opt/hp/hp-snmp-agents/server/etc/cmastdeqd","./opt/hp/hp-snmp-agents/server/etc/cmathreshd","./opt/hp/hp-snmp-agents/server/etc/cpqbssa.txt","./opt/hp/hp-snmp-agents/server/etc/cpqriisd","./opt/hp/hp-snmp-agents/share","./opt/hp/hp-snmp-agents/share/doc","./opt/hp/hp-snmp-agents/share/doc/HP_SNMP_Trap_Guide.txt","./opt/hp/hp-snmp-agents/storage","./opt/hp/hp-snmp-agents/storage/bin","./opt/hp/hp-snmp-agents/storage/bin/cmaeventd","./opt/hp/hp-snmp-agents/storage/bin/cmafcad","./opt/hp/hp-snmp-agents/storage/bin/cmaidad","./opt/hp/hp-snmp-agents/storage/bin/cmaided","./opt/hp/hp-snmp-agents/storage/bin/cmasasd","./opt/hp/hp-snmp-agents/storage/bin/cmascsid","./opt/hp/hp-snmp-agents/storage/bin/libcpqimgr-x86_64.so","./opt/hp/hp-snmp-agents/storage/etc","./opt/hp/hp-snmp-agents/storage/etc/cmaeventd","./opt/hp/hp-snmp-agents/storage/etc/cmafcad","./opt/hp/hp-snmp-agents/storage/etc/cmaidad","./opt/hp/hp-snmp-agents/storage/etc/cmaided","./opt/hp/hp-snmp-agents/storage/etc/cmasasd","./opt/hp/hp-snmp-agents/storage/etc/cmascsid","./opt/hp/hp-snmp-agents/storage/etc/cmastorobjects.conf","./opt/hp/hp-snmp-agents/utils","./opt/hp/hp-snmp-agents/utils/usb-device.sh","./opt/hp/hp-snmp-agents/webagent","./opt/hp/hp-snmp-agents/webagent/csginkgo","./sbin/hpsnmpconfig","./usr/lib/systemd/scripts/hp-snmp-agents.sh","./usr/lib/systemd/system/hp-snmp-agents.service","./usr/lib64/libcmaX64.so","./usr/lib64/libcmaX64.so.1","./usr/lib64/libcmaX64.so.1.0","./usr/lib64/libcmacommon64.so","./usr/lib64/libcmacommon64.so.1","./usr/lib64/libcmacommon64.so.1.0","./usr/lib64/libcmaconf64.so","./usr/lib64/libcmaconf64.so.1","./usr/lib64/libcmaconf64.so.1.0","./usr/lib64/libcmapeer64.so","./usr/lib64/libcmapeer64.so.1","./usr/lib64/libcmapeer64.so.1.0","./usr/share/man/man4/hp-snmp-agents.4.gz","./usr/share/man/man8/cmanicd.8.gz","./usr/share/smartupdate/hp-snmp-agents/component.xml","./var/log/hp-snmp-agents","./var/spool/compaq"],"md5sum":"043df2ca2149791bc57d4c79246734d2","name":"hp-snmp-agents-10.94-689.8.rhel7.x86_64.rpm","release":"2021-08-25T03:40:14","revision":"0","sha1sum":"b6f89b85896995585854062cdb946f553d4bddac","size":"1MB","target_guids":[],"type_of_change":"0","version":"10.9.4"}],"id":{"product":"067bbc5cffe1421194a0097838afd34e","version":"aa485fc51f2943829285456ca7c8b8bf"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<P>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</P>\n<P>To install the package, type: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<B><I>rpm -ivh hp-snmp-agents-&lt;version&gt;.rpm</I></B></P>\n<P>To check whether the package is loaded properly type: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<B><I>/etc/init.d/hp-snmp-agents status</I></B></P>\n<P>Additional help is available by typing: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<B><I>man hp-snmp-agents</I></B></P>"},{"lang":"ja","x_late":"<P>システム管理者（root）としてログインし、RPMをご使用のハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</P>\n<P>パッケージをインストールするには、次のようにタイプします。</P>\n<P>         <B><I>rpm -ivh hp-snmp-agents-<version>.rpm</I></B></P>\n<P>パッケージが正しくロードされているか、以下をタイプして確認します。</P>\n<P>         <B><I>/etc/init.d/hp-snmp-agents status</I></B></P>\n<P>以下のコマンドを実行してヘルプを参照してください。</P>\n<P>         <B><I>man hp-snmp-agents</I></B></P>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Red Hat Enterprise Linux 7 伺服器 的 HPE SNMP 代理程式"},{"lang":"en","x_late":"HPE SNMP Agents for Red Hat Enterprise Linux 7 Server"},{"lang":"ko","x_late":"Red Hat Enterprise Linux 7 서버용 HPE SNMP 에이전트"},{"lang":"cn","x_late":"Red Hat Enterprise Linux 7 Server版HPE SNMP Agents"},{"lang":"ja","x_late":"HPE SNMPエージェント for Red Hat Enterprise Linux 7 Server"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"3309","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3307","subdev":"3309","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-28T13:02:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>Addressed issue where the HPE Synergy 3820C 10/20Gb Converged Network Adapter was showing not supported</li>\n\t<li>Corrected invalid utf8mb4 char in database</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>TBD</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"J06","value":"HP ProLiant MicroServer Gen8"},{"key":"I24","value":"HP ProLiant BL460c G6 Server"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A16","value":"HP ProLiant DL585 G7 Server"},{"key":"I25","value":"HP ProLiant BL680c G7 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 v2 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"A19","value":"HP ProLiant BL465c G7 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"P78","value":"HP ProLiant ML310e Gen8 v2 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"I27","value":"HP ProLiant BL460c G7 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"P64","value":"HP ProLiant DL360 G6 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P62","value":"HP ProLiant DL380 G6 Server"},{"key":"A24","value":"HP ProLiant SL335s G7 Server"},{"key":"P68","value":"HP ProLiant DL360 G7 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P88","value":"HP ProLiant ML10 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"O41","value":"HP ProLiant MicroServer"},{"key":"A20","value":"HP ProLiant BL685c G7 Server"},{"key":"P67","value":"HP ProLiant DL380 G7 Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"P65","value":"HP ProLiant DL580 G7 Server"}],"sw_keys":[{"name":"hp-snmp-agents","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWRTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-30475752544e","Version":"HPG2"},{"DeviceName":"MB012000GWRTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-30475752544c","Version":"HPG2"},{"DeviceName":"MB010000GWRTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-30475752544b","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB014000GWRTN, MB012000GWRTL and MB010000GWRTK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) -&nbsp;MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp; </strong>None</p>\n"}],"files":[{"bytes":"4031920","datemodified":"2021-07-23T10:26:13","file_list":["cp048544.xml","cpqsetup.exe","payload.json","setup.dll","SMOBULABPTG2.rel"],"md5sum":"4a46117a43a7dc4d04d0a61e6b8aa0b4","name":"cp048544.exe","release":"2021-07-23T10:18:16","revision":"0","sha1sum":"cad4056c1bf0f36874627410ce13934455267c02","size":"3MB","target_guids":["4d2340a5-3042-3431-3030-30475752544e","4d2340a5-3042-3231-3030-30475752544c","4d2340a5-3042-3031-3030-30475752544b"],"type_of_change":"1","version":"HPG2"}],"id":{"product":"ed9a4b98eb61471ab66480b22d4e9c4f","version":"de6dfaa64e5340059e5e3bc9609569ca"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB014000GWRTN、MB012000GWRTLおよびMB010000GWRTKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB014000GWRTN","target_guid":"4d2340a5-3042-3431-3030-30475752544e","type":"sata"},{"id":"MB012000GWRTL","target_guid":"4d2340a5-3042-3231-3030-30475752544c","type":"sata"},{"id":"MB010000GWRTK","target_guid":"4d2340a5-3042-3031-3030-30475752544b","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T11:23:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB010000GWRTK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB014000GWRTN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB012000GWRTL","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWFWK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRH620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-30475746574b","Version":"HPG6"},{"DeviceName":"MB002000GWFWL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRH620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-30475746574c","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB001000GWFWK and MB002000GWFWL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB001000GWFWK and MB002000GWFWL Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG5</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG5<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp; &nbsp;&nbsp; None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"18199095","datemodified":"2021-08-30T18:55:12","file_list":["/CP048302_BUILD_8.data","/CP048302.vmexe","/CP048302.vmexe64","/CP048302.vmfile","/CP048302_VMw.zip","/CP048302.xml","/payload.json","/CP048302_VMw.zip/index.xml","/CP048302_VMw.zip/vendor-index.xml","/CP048302_VMw.zip/metadata.zip","/CP048302_VMw.zip/vib20/CP048302/HPE_bootbank_CP048302_HPG6.8-7.0.0.15843807.vib","/CP048302_VMw.zip/metadata.zip/vendor-index.xml","/CP048302_VMw.zip/metadata.zip/vmware.xml","/CP048302_VMw.zip/metadata.zip/vibs/CP048302-3566367639286406938.xml","/CP048302_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048302_HPG6.8-7.0.0.15843807.xml"],"md5sum":"d19f15a081859eb76b7a5b463494b6d1","name":"CP048302.zip","release":"2021-08-30T18:50:19","revision":"0","sha1sum":"ecc98d59b4ad46c1ce404324bf268833194c1af9","size":"17MB","target_guids":["4d2340a5-3042-3130-3030-30475746574b","4d2340a5-3042-3230-3030-30475746574c"],"type_of_change":"1","version":"HPG6","vib_list":[{"name":"CP048302","version":"HPG6.8-7.0.0.15843807"}]}],"id":{"product":"25298d41e8ae4c7a847f78be945ec24d","version":"0ab24257452b4a809cb343a2d29d105e"},"installation":{"command":"CP040785.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB001000GWFWK and MB002000GWFWL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor ESXi - MB001000GWFWKおよびMB002000GWFWLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB001000GWFWK","target_guid":"4d2340a5-3042-3130-3030-30475746574b","type":"sata"},{"id":"MB002000GWFWL","target_guid":"4d2340a5-3042-3230-3030-30475746574c","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-03T11:31:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB002000GWFWL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB001000GWFWK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following storage controllers: Smart Array P220i, P222, P420i, P420, P421, P721m, and P822"},{"lang":"cn","x_late":"该x64智能组件为以下存储控制器提供固件： 智能阵列 P220i、P222、P420i、P420、P421、P721m 和 P822"},{"lang":"tw","x_late":"此 x64 智慧型元件提供適用於下列儲存控制器的韌體： Smart Array P220i、P222、P420i、P420、P421、P721m 及 P822"},{"lang":"ko","x_late":"이 x64 스마트 구성 요소는 다음과 같은 스토리지 컨트롤러용 펌웨어를 제공합니다. 스마트 어레이 P220i, P222, P420i, P420, P421, P721m 및 P822"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のストレージコントローラー：SmartアレイP220i, P222, P420i, P420, P421, P721m, およびP822のファームウェアを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Supplemental Update / Online ROM Flash Component for Linux (x64) - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822<br />\n&nbsp;</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 8.32<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;8.00&nbsp;&nbsp;&nbsp;<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 8.00<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Improved accuracy of drive temperature reporting feature</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type: square;\">\n\t<li>\n\t<p>System can potentially stop responding with no lockup code due to livelock condition where the RAID Stack thread is polling a queue for a completion to be returned by the base code firmware</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"},{"lang":"ja","x_late":"<p><strong>Deliverable Name:</strong><br />\n     Supplemental Update / Online ROM Flash Component for Linux (x64) - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822<br />\n </p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n     8.32<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n     8.00   <br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n     8.00<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n     None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Improved accuracy of drive temperature reporting feature</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type: square;\">\n\t<li>\n\t<p>System can potentially stop responding with no lockup code due to livelock condition where the RAID Stack thread is polling a queue for a completion to be returned by the base code firmware</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n     None</p>\n"}],"files":[{"bytes":"8755941","datemodified":"2017-10-16T11:58:55","file_list":["./usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-46a4d957a7-8.32-1.1","./usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-46a4d957a7-8.32-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-46a4d957a7-8.32-1.1/.hpsetup","./usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-46a4d957a7-8.32-1.1/746374726C00.firmware.bin.fw","./usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-46a4d957a7-8.32-1.1/747365700069443232323073620076312E303200.Baz-102.fuf.fw","./usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-46a4d957a7-8.32-1.1/CP033363.xml","./usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-46a4d957a7-8.32-1.1/d2220sb.bin.fw","./usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-46a4d957a7-8.32-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-46a4d957a7-8.32-1.1/libhpsetup.so","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP033363.scexe"],"md5sum":"a6aa4e791e8c7c75f48492747b43a9a2","name":"hp-firmware-smartarray-46a4d957a7-8.32-1.1.x86_64.rpm","release":"2017-11-02T00:00:00","revision":"1","sha1sum":"c16cb85556b60d704312f03122665e5bf4a95431","size":"8MB","target_guids":[],"type_of_change":"1","version":"8.32"}],"id":{"product":"8e395b40b6dc47ff9696c46179cb8065","version":"1a1af9dc05eb4548a8669347b5620e98"},"installation":{"command":"CP033363.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActiveIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Smart Array HPCISSS3 Controller Driver version 100.18.2.64 must not be used for firmware update.  Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfd368f11","ServerModel":["*"],"Target_guids":[],"Type":"NE","Version":"100.18.2.64","description":"HPE ProLiant Smart Array HPCISSS3 Controller Driver version 100.18.2.64 must not be used for firmware update.  Update the driver and reboot before attempting firmware update."}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong><em>Updating firmware with rpm installed:</em></strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li>\n\t<li>The&nbsp;CP033363.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-46a4d957a7-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:&nbsp;</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP033363.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-46a4d957a7-*&#39; location</p>\n\n<ul>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><strong><em>Updating firmware without installing the rpm:</em></strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-46a4d957a7-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-46a4d957a7-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps</p>\n\n<p><strong>To use HP Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hp.com/go/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\"><u>USB Key Utility for Windows</u></a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li>\n\t<li>Run launch_sum.sh script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong><em>Updating firmware with rpm installed:</em></strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:  <em>rpm -ivh <rpm_filename>.  </em>This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location</li>\n\t<li>The CP033363.scexe script is located in the 'scexe-compat' folder. The actual name of the 'firmware-smartarray-46a4d957a7-*' folder is based on the version of the rpm installed in the first step above</li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands: </li>\n</ul>\n\n<p>               # ./CP033363.scexe in the '/usr/lib/x86_64-linux-gnu/scexe-compat' location (OR)</p>\n\n<p>               # <em>./setup</em> in the '/usr/lib/x86_64-linux-gnu/firmware-smartarray-46a4d957a7-*' location</p>\n\n<ul>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e <rpm_package_name></em>, which is the rpm filename without the '.rpm' extension</li>\n</ul>\n\n<p><strong><em>Updating firmware without installing the rpm:</em></strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio <rpm_filename>.rpm | cpio -id.  </em>This extracts the contents of the rpm to 'usr' folder in the current directory</li>\n\t<li>Navigate to the 'usr/lib/x86_64-linux-gnu/firmware-smartarray-46a4d957a7-*' location and run <em>./setup</em> to update the firmware. The actual name of the 'firmware-smartarray-46a4d957a7-*' folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.  It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps</p>\n\n<p><strong>To use HP Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hp.com/go/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\"><u>USB Key Utility for Windows</u></a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li>\n\t<li>Run launch_sum.sh script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p> </p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Supplemental Update / Online ROM Flash Component for Linux (x64) - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822"},{"lang":"cn","x_late":"Linux (x64)版补充更新 /在线ROM刷新组件 - 智能阵列 P220i、P222、P420i、P420、P421、P721m和P822"},{"lang":"tw","x_late":"適用於 Linux (x64) 的補充更新/線上 ROM 更新元件 - Smart Array P220i、P222、P420i、P420、P421、P721m 與 P822"},{"lang":"ko","x_late":"Linux(x64)용 추가 업데이트/온라인 ROM 플래시 구성 요소 - 스마트 어레이 P220i, P222, P420i, P420, P421, P721m 및 P822"},{"lang":"ja","x_late":"サプリメンタルアップデート / オンラインROMフラッシュコンポーネント for Linux (x64) - SmartアレイP220i、P222、P420i、P420、P421、P721m、およびP822"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"323b","subdev":"3352","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3351","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3354","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3350","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3355","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3353","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323B","subdev":"3356","subven":"103C","target_guid":"","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"10","minor":"0","name":"SUSE LINUX Enterprise Server 10 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2017-12-08T09:36:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Improved accuracy of drive temperature reporting feature</p>\n","latest_fixes_x_late":"<p>System can potentially stop responding with no lockup code due to livelock condition where the RAID Stack thread is polling a queue for a completion to be returned by the base code firmware</p>\n"},{"curr_enhancements_x_late":"<p>Improved accuracy of drive temperature reporting feature</p>\n","curr_fixes_x_late":"<p>System can potentially stop responding with no lockup code due to livelock condition where the RAID Stack thread is polling a queue for a completion to be returned by the base code firmware</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P74","value":"HP ProLiant SL140s Gen8 Server (private)"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"3355103c","sw_key_expectedpath":"firmware"},{"name":"3352103c","sw_key_expectedpath":"firmware"},{"name":"3356103C","sw_key_expectedpath":"firmware"},{"name":"3351103c","sw_key_expectedpath":"firmware"},{"name":"D2220sb","sw_key_expectedpath":"firmware"},{"name":"3350103c","sw_key_expectedpath":"firmware"},{"name":"3354103c","sw_key_expectedpath":"firmware"},{"name":"3353103c","sw_key_expectedpath":"firmware"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000240GWKVK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3234-3047574b564b","Version":"HPG5"},{"DeviceName":"MK000480GWJPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-3047574a504e","Version":"HPG5"},{"DeviceName":"MK000960GWJPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-3047574a5050","Version":"HPG5"},{"DeviceName":"MK001920GWJPQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-3047574a5051","Version":"HPG5"},{"DeviceName":"VK000240GWJPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-3047574a5044","Version":"HPG5"},{"DeviceName":"VK000480GWJPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-3047574a5045","Version":"HPG5"},{"DeviceName":"VK000960GWJPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-3047574a5046","Version":"HPG5"},{"DeviceName":"VK001920GWJPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-3047574a5048","Version":"HPG5"},{"DeviceName":"VK003840GWJPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-3047574a504b","Version":"HPG5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Fixes a rare link loss issue and adds enhancements for drive reliability.</li>\n\t<li>After HPG5 firmware is downloaded to the drive, the new HPG5 firmware will be active on the drive.</li>\n\t<li>The new drive bootloader code will be activated after the next drive power cycle.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"3012584","datemodified":"2021-07-25T21:11:29","file_list":["4IYVHPG5.rel","cp048664.xml","cpqsetup.exe","payload.json","setup.dll"],"md5sum":"2d0bc3b289dc278d145b0b549659c144","name":"cp048664.exe","release":"2021-07-25T21:04:05","revision":"0","sha1sum":"ecd0b0a813ca490189748d9659fd0b9d3c3345f5","size":"2MB","target_guids":["4d2340a5-304b-3030-3234-3047574b564b","4d2340a5-304b-3030-3438-3047574a504e","4d2340a5-304b-3030-3936-3047574a5050","4d2340a5-304b-3130-3932-3047574a5051","562340a5-304b-3030-3234-3047574a5044","562340a5-304b-3030-3438-3047574a5045","562340a5-304b-3030-3936-3047574a5046","562340a5-304b-3130-3932-3047574a5048","562340a5-304b-3330-3834-3047574a504b"],"type_of_change":"2","version":"HPG5"}],"id":{"product":"01713b1febed4cc9a463023eeb2cf6ee","version":"ede24ea822904ca78180810df9309f40"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  VK000240GWJPD、VK000480GWJPE、VK000960GWJPF、VK001920GWJPH、VK003840GWJPK、MK000240GWKVK、MK000480GWJPN、MK000960GWJPPおよびMK001920GWJPQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MK001920GWJPQ","target_guid":"4d2340a5-304b-3130-3932-3047574a5051","type":"sata"},{"id":"VK001920GWJPH","target_guid":"562340a5-304b-3130-3932-3047574a5048","type":"sata"},{"id":"MK000240GWKVK","target_guid":"4d2340a5-304b-3030-3234-3047574b564b","type":"sata"},{"id":"VK000240GWJPD","target_guid":"562340a5-304b-3030-3234-3047574a5044","type":"sata"},{"id":"VK003840GWJPK","target_guid":"562340a5-304b-3330-3834-3047574a504b","type":"sata"},{"id":"MK000480GWJPN","target_guid":"4d2340a5-304b-3030-3438-3047574a504e","type":"sata"},{"id":"VK000480GWJPE","target_guid":"562340a5-304b-3030-3438-3047574a5045","type":"sata"},{"id":"MK000960GWJPP","target_guid":"4d2340a5-304b-3030-3936-3047574a5050","type":"sata"},{"id":"VK000960GWJPF","target_guid":"562340a5-304b-3030-3936-3047574a5046","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-17T07:02:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":"<ul>\n\t<li>Fixes a rare link loss issue and adds enhancements for drive reliability.</li>\n\t<li>After HPG5 firmware is downloaded to the drive, the new HPG5 firmware will be active on the drive.</li>\n\t<li>The new drive bootloader code will be activated after the next drive power cycle.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us</a></li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Fixes a rare link loss issue and adds enhancements for drive reliability.</li>\n\t<li>After HPG5 firmware is downloaded to the drive, the new HPG5 firmware will be active on the drive.</li>\n\t<li>The new drive bootloader code will be activated after the next drive power cycle.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK001920GWJPQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GWJPH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000240GWKVK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWJPN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWJPP","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWJPE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWJPD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWJPF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GWJPK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB8000JFECQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRPSD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3842-3030-304a46454351","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB8000JFECQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB8000JFECQ Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD4</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong>&nbsp;&nbsp;&nbsp;&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp; None&nbsp;<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None&nbsp;</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"17803385","datemodified":"2021-08-27T04:55:37","file_list":["/CP048382_BUILD_2.data","/CP048382.vmexe","/CP048382.vmexe64","/CP048382.vmfile","/CP048382_VMw.zip","/CP048382.xml","/payload.json","/CP048382_VMw.zip/index.xml","/CP048382_VMw.zip/vendor-index.xml","/CP048382_VMw.zip/metadata.zip","/CP048382_VMw.zip/vib20/CP048382/HPE_bootbank_CP048382_HPD7.2-7.0.0.15843807.vib","/CP048382_VMw.zip/metadata.zip/vendor-index.xml","/CP048382_VMw.zip/metadata.zip/vmware.xml","/CP048382_VMw.zip/metadata.zip/vibs/CP048382--1568442986019898908.xml","/CP048382_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048382_HPD7.2-7.0.0.15843807.xml"],"md5sum":"e5955c566ea05a52c19e0d144434e9d6","name":"CP048382.zip","release":"2021-08-27T04:50:20","revision":"0","sha1sum":"c1a107bae5126ecaab965e613077de91a454bb6a","size":"16MB","target_guids":["002340a5-4d00-3842-3030-304a46454351"],"type_of_change":"1","version":"HPD7","vib_list":[{"name":"CP048382","version":"HPD7.2-7.0.0.15843807"}]}],"id":{"product":"b02d63095f7c44f5ba3d7deb6bb4021a","version":"38a149a277564d6591ace3cb1d3e3dc6"},"installation":{"command":"CP040532.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB8000JFECQ Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB8000JFECQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB8000JFECQ","target_guid":"002340a5-4d00-3842-3030-304a46454351","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T09:22:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB8000JFECQ","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HP Ethernet 1Gb 2-port 332i Adapter (22E8)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//332i-2x1G-14E4-165F-103C-22E8.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C22E8","Version":"20.18.31"},{"DeviceName":"HP Ethernet 1Gb 2-port 330i Adapter (22BD)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//330i-2x1G-14E4-1665-103C-22BD.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1665103C22BD","Version":"20.18.31"},{"DeviceName":"HP Ethernet 1Gb 2-port 332T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//332T-2x1G-14E4-165F-103C-1786.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C1786","Version":"20.18.31"},{"DeviceName":"HP Ethernet 1Gb 4-port 331FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331FLR-4x1G-14E4-1657-103C-169D.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C169D","Version":"20.18.31"},{"DeviceName":"HP Ethernet 1Gb 4-port 331T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331T-4x1G-14E4-1657-103C-3383.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C3383","Version":"20.18.31"},{"DeviceName":"HP Ethernet 1Gb 4-port 331i Adapter (22BE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331i-4x1G-14E4-1657-103C-22BE.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C22BE","Version":"20.18.31"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"tw","x_late":"此套件包含可升級 HPE ProLiant Broadcom NX1 Gigabit 乙太網路網路卡啟動碼、PXE、UEFI、NCSI 及 CCM 碼的公用程式與二進位檔，適用於 Linux x86_64。"},{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NX1 Gigabit Ethernet NICs Boot code, PXE, UEFI, NCSI, and CCM code running under Linux x86_64 platform."},{"lang":"ko","x_late":"이 패키지에는 Linux x86_64 플랫폼에서 실행되는 HPE ProLiant Broadcom NX1 기가비트 이더넷 NIC 부팅 코드, PXE, UEFI, NCSI 및 CCM 코드를 업그레이드하기 위한 유틸리티와 바이너리가 포함되어 있습니다."},{"lang":"cn","x_late":"该软件包内含实用程序和二进制文件，可用于升级在Linux x86_64平台下运行的HPE ProLiant Broadcom NX1千兆以太网卡启动代码、PXE、UEFI、NCSI和CCM代码。"},{"lang":"ja","x_late":"このパッケージには、Linux x86_64プラットフォームで動作するHPE ProLiant Broadcom NX1 Gigabit Ethernet NICブートコード、PXE、UEFI、NCSI、およびCCMコードをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains combo image v20.18.31&nbsp;with the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"2\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>NIC</strong></td>\n\t\t\t<td><strong>Boot Code Version</strong></td>\n\t\t\t<td><strong>PXE Version</strong></td>\n\t\t\t<td><strong>NCSI Version</strong></td>\n\t\t\t<td><strong>UEFI Version</strong></td>\n\t\t\t<td><strong>CCM Version</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 1Gb 2-port 330i Adapter (22BD)</td>\n\t\t\t<td>2.10</td>\n\t\t\t<td>21.6.0</td>\n\t\t\t<td>1.5.27</td>\n\t\t\t<td>21.6.12</td>\n\t\t\t<td>218.0.10.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 1Gb 4-port 331i Adapter (22BE)<br />\n\t\t\tHPE Ethernet 1Gb 4-port 331FLR Adapter<br />\n\t\t\tHPE Ethernet 1Gb 4-port 331T Adapter</td>\n\t\t\t<td>1.46</td>\n\t\t\t<td>21.6.0</td>\n\t\t\t<td>1.5.27</td>\n\t\t\t<td>21.6.12</td>\n\t\t\t<td>218.0.10.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 1Gb 2-port 332i Adapter (22E8)<br />\n\t\t\tHPE Ethernet 1Gb 2-port 332T Adapter</td>\n\t\t\t<td>1.40</td>\n\t\t\t<td>21.6.0</td>\n\t\t\t<td>1.5.27</td>\n\t\t\t<td>21.6.12</td>\n\t\t\t<td>218.0.10.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"4256442","datemodified":"2021-01-21T07:56:56","file_list":["./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.27.6-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.27.6-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.27.6-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.27.6-1.1/CP045012.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.27.6-1.1/CP045012.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.27.6-1.1/CPINIT","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.27.6-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.27.6-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.27.6-1.1/deps/libs/libbmapi_x64.so.6","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.27.6-1.1/deps/libs/libbrcm_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.27.6-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.27.6-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.27.6-1.1/nic_fw/330i-2x1G-14E4-1665-103C-22BD.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.27.6-1.1/nic_fw/331FLR-4x1G-14E4-1657-103C-169D.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.27.6-1.1/nic_fw/331T-4x1G-14E4-1657-103C-3383.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.27.6-1.1/nic_fw/331i-4x1G-14E4-1657-103C-22BE.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.27.6-1.1/nic_fw/332T-2x1G-14E4-165F-103C-1786.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.27.6-1.1/nic_fw/332i-2x1G-14E4-165F-103C-22E8.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.27.6-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.27.6-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045012.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045012.scexe"],"md5sum":"0663883a1e3c8d3ad18c560b118d32b8","name":"firmware-nic-broadcom-2.27.6-1.1.x86_64.rpm","release":"2021-01-21T07:43:06","revision":"0","sha1sum":"4b706b3bed12ed777070417c8955dafe7ff43567","size":"4MB","target_guids":["a6b1a447-382a-5a4f-14E4-165F103C22E8","a6b1a447-382a-5a4f-14E4-1665103C22BD","a6b1a447-382a-5a4f-14E4-165F103C1786","a6b1a447-382a-5a4f-14E4-1657103C169D","a6b1a447-382a-5a4f-14E4-1657103C3383","a6b1a447-382a-5a4f-14E4-1657103C22BE"],"type_of_change":"0","version":"2.27.6"}],"id":{"product":"bf3a285848ac4632b8eb3d00276b79b4","version":"3b7a3d2719434e0abdc9438ebd3ca680"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Broadcom tg3 Ethernet Driver version 3.137e-3 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"6.6"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"3.137e-3","description":"HP Broadcom tg3 Ethernet Driver version 3.137e-3 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><em><strong>Steps to update the adapter firmware using the rpm pacakge:</strong></em></p>\n\n<ul>\n\t<li>Install the firmware rpm package:<br />\n\t<em>&gt; rpm -ivh &lt;rpm_filename&gt;.rpm </em></li>\n\t<li>Check where the files are extracted:<br />\n\t<em>&gt; rpm -qlp &lt;rpm_filename&gt;.rpm</em></li>\n\t<li>Using the output from the previous step determine the location of hpsetup file, change to that directory and run &#39;<em>./hpsetup</em>&#39; to update the firmware.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>Further information&nbsp;is available in CP045012.txt file.The results of the firmware upgrade are saved&nbsp;in CP045012.log at &quot;/var/cpq/.&quot;</li>\n\t<li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li>\n\t<li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware, it merely extracts the contents of the rpm package to the local system. Updating the adapter firmware requires following the steps outlined above.</li>\n</ul>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 Linux x86_64 的 HPE Broadcom NX1 線上韌體升級公用程式"},{"lang":"en","x_late":"HPE Broadcom NX1 Online Firmware Upgrade Utility for Linux x86_64"},{"lang":"ko","x_late":"Linux x86_64용 HPE Broadcom NX1 온라인 펌웨어 업그레이드 유틸리티"},{"lang":"cn","x_late":"Linux x86_64版HPE Broadcom NX1在线固件升级实用程序"},{"lang":"ja","x_late":"HPE Broadcom NX1オンラインファームウェアアップグレードユーティリティ for Linux x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"165F","subdev":"22E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c22e8","type":"pci","ven":"14E4"},{"dev":"1665","subdev":"22BD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1665103c22bd","type":"pci","ven":"14E4"},{"dev":"165F","subdev":"1786","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c1786","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"169D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c169d","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"3383","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c3383","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"22BE","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c22be","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects the wrong spare number while it was originally not the same as what was written on the label of package.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue about lack of information under AHS log.</li>\n\t<li>This product addresses an RSOD issue which appeared intermittently during POST after having a warm reboot.</li>\n\t<li>This product addresses a modification on help string of Family Firmware Version.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"BCM","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following storage controllers: Smart Array and Smart HBA H240ar, H240nr, H240, H241, H244br, P240nr, P244br, P246br, P440ar, P440, P441, P542D, P741m, P840, P840ar, and P841"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のストレージコントローラーのファームウェアを提供します。SmartアレイおよびSmart HBA H240ar、H240nr、H240、H241、H244br、P240nr、P244br、P246br、P440ar、P440、P441、P542D、P741m、P840、P840arおよびP841"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for VMware ESXi - Smart Array&nbsp;and Smart HBA H240ar, H240nr, H240, H241, H244br, P240nr, P244br, P246br, P440ar, P440, P441, P542D, P741m, P840, P840ar, and&nbsp;P841<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; 7.00(D)</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; 7.00(C)<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;7.00<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong>&nbsp; &nbsp;&nbsp;</p>\n\n<ul>\n\t<li>&nbsp; &nbsp; Initial release for Snap4</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"9640222","datemodified":"2021-03-25T13:55:58","file_list":["/CP047335.vmexe","/CP047335.vmexe64","/CP047335.vmfile","/CP047335.xml","/payload.json","/README.txt"],"md5sum":"b0535676e0bf0ee10e6e8d954a9f5810","name":"CP047335.zip","release":"2021-03-25T13:41:06","revision":"0","sha1sum":"c82633aea1b1a6d0dbec617a9851e7c548336611","size":"9MB","target_guids":[],"type_of_change":"1","version":"7.00","vib_list":[]}],"id":{"product":"820627433dee4bc3a4a1adb64a0c3d74","version":"05408484df0845c39625044662151743"},"installation":{"command":"CP047335.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Smart Array Controller Driver version 3.4.4 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec21fe94e4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"3.4.4-0","description":"HP ProLiant Smart Array Controller Driver version 3.4.4 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Smart Array Controller Driver version 3.4.6 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec21fe94e4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"3.4.6-0","description":"HP ProLiant Smart Array Controller Driver version 3.4.6 or greater is required and should be already active"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActiveIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Smart Array HPCISSS3 Controller Driver version 100.18.2.64 must not be used for firmware update.  Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfd368f11","ServerModel":["*"],"Target_guids":[],"Type":"NE","Version":"100.18.2.64","description":"HPE ProLiant Smart Array HPCISSS3 Controller Driver version 100.18.2.64 must not be used for firmware update.  Update the driver and reboot before attempting firmware update."}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at: <a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;<br />\n<strong>To use HPE Insight Control for vCenter:</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware ESXi - Smart Array and Smart HBA H240ar, H240nr, H240, H241, H244br, P240nr, P244br, P246br, P440ar, P440, P441, P542D, P741m, P840, P840ar, and  P841"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor VMware ESXi - SmartアレイおよびSmart HBA H240ar、H240nr、H240、H241、H244br、P240nr、P244br、P246br、P440ar、P440、P441、P542D、P741m、P840、P840arおよびP841"}],"prerequisites":{"required_diskspace":{"size_kb":"12000"},"supported_devices":[{"dev":"3239","subdev":"21c3","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c0","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c2","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21BD","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c7","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21bf","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c6","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cb","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21be","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c5","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ca","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c8","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21CD","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cc","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ce","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c1","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-04-23T09:30:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added ESXi 7.0 support.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Improved flash engine efficiency</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"21be103c","sw_key_expectedpath":"firmware"},{"name":"21CD103c","sw_key_expectedpath":"firmware"},{"name":"21cb103c","sw_key_expectedpath":"firmware"},{"name":"21BD103c","sw_key_expectedpath":"firmware"},{"name":"21c6103c","sw_key_expectedpath":"firmware"},{"name":"21c1103c","sw_key_expectedpath":"firmware"},{"name":"21c5103c","sw_key_expectedpath":"firmware"},{"name":"21cc103c","sw_key_expectedpath":"firmware"},{"name":"21c2103c","sw_key_expectedpath":"firmware"},{"name":"21c8103c","sw_key_expectedpath":"firmware"},{"name":"21c3103c","sw_key_expectedpath":"firmware"},{"name":"21bf103c","sw_key_expectedpath":"firmware"},{"name":"21c7103c","sw_key_expectedpath":"firmware"},{"name":"21ca103c","sw_key_expectedpath":"firmware"},{"name":"21ce103c","sw_key_expectedpath":"firmware"},{"name":"21c0103c","sw_key_expectedpath":"firmware"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000JWDFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEAHssseFD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57444644","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB012000JWDFD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB012000JWDFD Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"4165944","datemodified":"2021-07-25T18:21:08","file_list":["cp048634.xml","cpqsetup.exe","HLEAHssseFD3.rel","payload.json","setup.dll"],"md5sum":"00eb7cb81a44dd53b8acff91e4db81fc","name":"cp048634.exe","release":"2021-07-25T18:14:04","revision":"0","sha1sum":"ede5a127b83922415ae448e74cd22096933cc01f","size":"3MB","target_guids":["4d2340a5-3042-3231-3030-304a57444644"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"4893b899f6404bf4b119e3e3a55be5b2","version":"318609d8c34f4520b93eea3446f7aeb5"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB012000JWDFD Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB012000JWDFDドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB012000JWDFD","target_guid":"4d2340a5-3042-3231-3030-304a57444644","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T14:50:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB012000JWDFD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG1800JFHMH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SEED8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3830-304a46484d48","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: EG1800JFHMH"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EG1800JFHMH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;EG1800JFHMH Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD7<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"16246561","datemodified":"2021-08-31T06:44:16","file_list":["/CP048270_BUILD_2.data","/CP048270.vmexe","/CP048270.vmexe64","/CP048270.vmfile","/CP048270_VMw.zip","/CP048270.xml","/payload.json","/CP048270_VMw.zip/index.xml","/CP048270_VMw.zip/vendor-index.xml","/CP048270_VMw.zip/metadata.zip","/CP048270_VMw.zip/vib20/CP048270/HPE_bootbank_CP048270_HPD8.2-7.0.0.15843807.vib","/CP048270_VMw.zip/metadata.zip/vendor-index.xml","/CP048270_VMw.zip/metadata.zip/vmware.xml","/CP048270_VMw.zip/metadata.zip/vibs/CP048270--344626177108592925.xml","/CP048270_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048270_HPD8.2-7.0.0.15843807.xml"],"md5sum":"ef0cad3431e577720737c40e66a36201","name":"CP048270.zip","release":"2021-08-31T06:39:33","revision":"0","sha1sum":"5bf9b784b8abc5a644cae8057dfb430ecb37836d","size":"15MB","target_guids":["002340a5-4500-3147-3830-304a46484d48"],"type_of_change":"1","version":"HPD8","vib_list":[{"name":"CP048270","version":"HPD8.2-7.0.0.15843807"}]}],"id":{"product":"b013dc662ea446dbabf5ade1d9cf8d6f","version":"37170fd2e4e84ddd94a64d5176b4718f"},"installation":{"command":"CP040626.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EG1800JFHMH Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EG1800JFHMHドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG1800JFHMH","target_guid":"002340a5-4500-3147-3830-304a46484d48","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-02T16:15:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>A low-probability, high severity corner case of sustained outer-diameter activity with emergency power off when heads are at the outer diameter prevented heads from parking/latching properly on a few drives in the field.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG1800JFHMH","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under Red Hat Enterprise Linux 7 Update 8 x86_64."},{"lang":"ja","x_late":"この製品は、Red Hat Enterprise Linux 7 Update 8 x86_64下で実行されるサポートされたHPE Broadcom NetXtreme-Eアダプターカードに関するRoCE（RDMA over Converged Ethernet）ライブラリを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"24868","datemodified":"2021-02-11T00:27:38","file_list":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib64/libbnxt_re-218.0.7.0.so","./usr/lib64/libbnxt_re-rdmav22.so","./usr/lib64/libbnxt_re.so","./usr/share/smartupdate/libbnxt_re/component.xml"],"md5sum":"eb14e67cd23e7263de189f1f945decea","name":"libbnxt_re-218.0.7.0-rhel7u8.x86_64.rpm","release":"2021-02-11T00:25:06","revision":"0","sha1sum":"f509521f96563f603288148a797028fc061e0e10","size":"24KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"type_of_change":"0","version":"218.0.7.0"}],"id":{"product":"a7b0a77ad412478f9ceb945592e1c7ab","version":"1214929690b34642a3e2d23b205788ee"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"text-align:left\">rpm -ivh &lt;bnxt_rooce &gt;.rpm --force [--replacefiles]</p>\n\n<p style=\"text-align:left\">Use --force or --replacefiles options while installing or updating the HPE Broadcom RoCE library which may conflict with inbox library</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E RoCE Library for Red Hat Enterprise Linux 7 Update 8"},{"lang":"ja","x_late":"Red Hat Enterprise Linux 7 Update 8用HPE Broadcom NetXtreme-E RoCEライブラリ"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>This product corrects an issue which RoCE bond is not getting created automatically after system reboot</li>\n\t<li>This product corrects an issue which errors/performance may degrades after hot plug operation is performed</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product now supports rdma-core v29(rdma user space application)</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"libbnxt_re","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000400JWFWN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a5746574e","Version":"HPD5"},{"DeviceName":"MO000800JWFWP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57465750","Version":"HPD5"},{"DeviceName":"MO001600JWFWQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57465751","Version":"HPD5"},{"DeviceName":"MO003200JWFWR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57465752","Version":"HPD5"},{"DeviceName":"MO000960JWFWT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3936-304a57465754","Version":"HPD5"},{"DeviceName":"MO001920JWFWU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a57465755","Version":"HPD5"},{"DeviceName":"MO003840JWFWV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3834-304a57465756","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MO000400JWFWN, MO000800JWFWP, MO001600JWFWQ, MO003200JWFWR, MO000960JWFWT, MO001920JWFWU and MO003840JWFWV"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MO000400JWFWN、MO000800JWFWP、MO001600JWFWQ、MO003200JWFWR、MO000960JWFWT、MO001920JWFWUおよびMO003840JWFWV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi&nbsp;- MO000400JWFWN, MO000800JWFWP, MO001600JWFWQ, MO003200JWFWR, MO000960JWFWT, MO001920JWFWU and MO003840JWFWV&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16058131","datemodified":"2021-08-27T07:17:12","file_list":["/CP048393_BUILD_3.data","/CP048393.vmexe","/CP048393.vmexe64","/CP048393.vmfile","/CP048393_VMw.zip","/CP048393.xml","/payload.json","/CP048393_VMw.zip/index.xml","/CP048393_VMw.zip/vendor-index.xml","/CP048393_VMw.zip/metadata.zip","/CP048393_VMw.zip/vib20/CP048393/HPE_bootbank_CP048393_HPD5.3-7.0.0.15843807.vib","/CP048393_VMw.zip/metadata.zip/vendor-index.xml","/CP048393_VMw.zip/metadata.zip/vmware.xml","/CP048393_VMw.zip/metadata.zip/vibs/CP048393-6166442019455905043.xml","/CP048393_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048393_HPD5.3-7.0.0.15843807.xml"],"md5sum":"5aa23c206817f2113a253045602c64cf","name":"CP048393.zip","release":"2021-08-27T07:11:43","revision":"0","sha1sum":"7c8dd7aad41fa526dfd94a19a9ec92b27e8d5964","size":"15MB","target_guids":["4d2340a5-304f-3030-3430-304a5746574e","4d2340a5-304f-3030-3830-304a57465750","4d2340a5-304f-3130-3630-304a57465751","4d2340a5-304f-3330-3230-304a57465752","4d2340a5-304f-3030-3936-304a57465754","4d2340a5-304f-3130-3932-304a57465755","4d2340a5-304f-3330-3834-304a57465756"],"type_of_change":"1","version":"HPD5","vib_list":[{"name":"CP048393","version":"HPD5.3-7.0.0.15843807"}]}],"id":{"product":"1d291170bb0944cd8d58e9257151b0f1","version":"74a9c297c9d44c55bb89ae88f1a0763b"},"installation":{"command":"CP041422.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MO000400JWFWN, MO000800JWFWP, MO001600JWFWQ, MO003200JWFWR, MO000960JWFWT, MO001920JWFWU and MO003840JWFWV Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MO000400JWFWN、MO000800JWFWP、MO001600JWFWQ、MO003200JWFWR、MO000960JWFWT、MO001920JWFWU、およびMO003840JWFWVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MO003200JWFWR","target_guid":"4d2340a5-304f-3330-3230-304a57465752","type":"sas"},{"id":"MO001920JWFWU","target_guid":"4d2340a5-304f-3130-3932-304a57465755","type":"sas"},{"id":"MO001600JWFWQ","target_guid":"4d2340a5-304f-3130-3630-304a57465751","type":"sas"},{"id":"MO000960JWFWT","target_guid":"4d2340a5-304f-3030-3936-304a57465754","type":"sas"},{"id":"MO000800JWFWP","target_guid":"4d2340a5-304f-3030-3830-304a57465750","type":"sas"},{"id":"MO000400JWFWN","target_guid":"4d2340a5-304f-3030-3430-304a5746574e","type":"sas"},{"id":"MO003840JWFWV","target_guid":"4d2340a5-304f-3330-3834-304a57465756","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T12:15:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MO003840JWFWV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200JWFWR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000400JWFWN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001920JWFWU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600JWFWQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000960JWFWT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800JWFWP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Blade QLogic NX2 10Gb and 20Gb Multifunction Gigabit Ethernet NICs running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 8で動作するHPE Blade QLogic NX2 10Gbおよび20GbマルチファンクションGigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"9092593","datemodified":"2021-08-12T02:05:19","file_list":["./etc/depmod.d/netxtreme2.conf","./etc/dracut.conf.d/netxtreme2.conf","./lib/modules","./lib/modules/4.18.0-305.el8.x86_64","./lib/modules/4.18.0-305.el8.x86_64/extra","./lib/modules/4.18.0-305.el8.x86_64/extra/netxtreme2","./lib/modules/4.18.0-305.el8.x86_64/extra/netxtreme2/bnx2.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/netxtreme2/bnx2fc.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/netxtreme2/bnx2i.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/netxtreme2/bnx2x.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/netxtreme2/cnic.ko","./usr/share/smartupdate/kmod-netxtreme2_bl/component.xml"],"md5sum":"1703eaf127d2379f14e466576bd3e4df","name":"kmod-netxtreme2_bl-7.14.80-5.rhel8u4.x86_64.rpm","release":"2021-08-12T01:43:06","revision":"0","sha1sum":"3e5663252085228a20c340ece6acd6f3d40e59e1","size":"8MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec63a13bba"],"type_of_change":"0","version":"7.14.80-5"},{"bytes":"8936001","datemodified":"2021-08-12T02:09:49","file_list":["./etc/depmod.d/netxtreme2.conf","./etc/dracut.conf.d/netxtreme2.conf","./lib/modules","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/netxtreme2","./lib/modules/4.18.0-240.el8.x86_64/extra/netxtreme2/bnx2.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/netxtreme2/bnx2fc.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/netxtreme2/bnx2i.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/netxtreme2/bnx2x.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/netxtreme2/cnic.ko","./usr/share/smartupdate/kmod-netxtreme2_bl/component.xml"],"md5sum":"9004dde55758c2c8ab44f915e5df8be0","name":"kmod-netxtreme2_bl-7.14.80-5.rhel8u3.x86_64.rpm","release":"2021-08-12T01:43:06","revision":"0","sha1sum":"cc9e9f5ced21c45ea57141aff0ceefc9df36b3c2","size":"8MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec63a13bba"],"type_of_change":"0","version":"7.14.80-5"}],"id":{"product":"b3f391bd1aa44685b17f74a3d4ddf32c","version":"33d71363769a4ee38d6f746498d85ac1"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE Blade QLogic NX2 10/20 GbEマルチファンクションドライバーfor Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"168E","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1933","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c22fa","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1917","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1916","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1933","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1916","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1917","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c22fa","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1933","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c22fa","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1916","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1917","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-09-03T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 8, Updates 2&nbsp;and 3.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 8 Update 4.</p>\n\n<p>This product now supports the&nbsp;HPE ProLiant BL660c Gen9 Server.&nbsp;</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"kmod-netxtreme2_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-netxtreme2_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-netxtreme2_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-netxtreme2_bl","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWTBK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304a5754424b","Version":"HPD9"},{"DeviceName":"VO001920JWTBL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304a5754424c","Version":"HPD9"},{"DeviceName":"VO003840JWTBN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304a5754424e","Version":"HPD9"},{"DeviceName":"VO007680JWTBP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304a57544250","Version":"HPD9"},{"DeviceName":"MO000400JWTBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57544251","Version":"HPD9"},{"DeviceName":"MO000800JWTBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57544252","Version":"HPD9"},{"DeviceName":"MO001600JWTBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57544254","Version":"HPD9"},{"DeviceName":"MO003200JWTBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57544255","Version":"HPD9"},{"DeviceName":"MO006400JWTCD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a57544344","Version":"HPD9"},{"DeviceName":"EO000400JWTBV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57544256","Version":"HPD9"},{"DeviceName":"EO000800JWTCA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57544341","Version":"HPD9"},{"DeviceName":"EO001600JWTCB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57544342","Version":"HPD9"},{"DeviceName":"EO003200JWTCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3330-3230-304a57544343","Version":"HPD9"},{"DeviceName":"MO001920JWWWV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a57575756","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA, EO001600JWTCB, EO003200JWTCC and MO001920JWWWV\n"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA, EO001600JWTCB, EO003200JWTCC およびMO001920JWWWV\n"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA,&nbsp; EO001600JWTCB, EO003200JWTCC and MO001920JWWWV Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4864845","datemodified":"2021-07-26T20:08:33","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPD9-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPD9-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPD9-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPD9-2.1/CP049145.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPD9-2.1/TAPM5ALLHPD9.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPD9-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPD9-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPD9-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPD9-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049145.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049145.scexe"],"md5sum":"436f3cd47f287ce14a753566190a127c","name":"firmware-hdd-9ad359dac1-HPD9-2.1.x86_64.rpm","release":"2021-07-26T19:56:05","revision":"0","sha1sum":"f10064fe9507e7ba04e8c8e28c8b01e57f807c5e","size":"4MB","target_guids":["562340a5-304f-3030-3936-304a5754424b","562340a5-304f-3130-3932-304a5754424c","562340a5-304f-3330-3834-304a5754424e","562340a5-304f-3730-3638-304a57544250","4d2340a5-304f-3030-3430-304a57544251","4d2340a5-304f-3030-3830-304a57544252","4d2340a5-304f-3130-3630-304a57544254","4d2340a5-304f-3330-3230-304a57544255","4d2340a5-304f-3630-3430-304a57544344","452340a5-304f-3030-3430-304a57544256","452340a5-304f-3030-3830-304a57544341","452340a5-304f-3130-3630-304a57544342","452340a5-304f-3330-3230-304a57544343","4d2340a5-304f-3130-3932-304a57575756"],"type_of_change":"1","version":"HPD9"}],"id":{"product":"c47b4b11bb744418a62b9ae668fd0ea6","version":"0a69bcbbf12d49ffb4d07264f2d06007"},"installation":{"command":"CP040601.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64)  - VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA and EO001600JWTCB Drives"},{"lang":"ja","x_late":"オンライン HDD/SSDフラッシュコンポーネントfor Linux (x64) - VO000960JWTBK、VO001920JWTBL、VO003840JWTBN、VO007680JWTBP、 MO000400JWTBQ、MO000800JWTBR、MO001600JWTBT、MO003200JWTBU、 MO006400JWTCD、EO000400JWTBV、EO000800JWTCA、EO001600JWTCBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VO007680JWTBP","target_guid":"562340a5-304f-3730-3638-304a57544250","type":"sas"},{"id":"MO006400JWTCD","target_guid":"4d2340a5-304f-3630-3430-304a57544344","type":"sas"},{"id":"VO003840JWTBN","target_guid":"562340a5-304f-3330-3834-304a5754424e","type":"sas"},{"id":"MO003200JWTBU","target_guid":"4d2340a5-304f-3330-3230-304a57544255","type":"sas"},{"id":"EO003200JWTCC","target_guid":"452340a5-304f-3330-3230-304a57544343","type":"sas"},{"id":"VO001920JWTBL","target_guid":"562340a5-304f-3130-3932-304a5754424c","type":"sas"},{"id":"MO001600JWTBT","target_guid":"4d2340a5-304f-3130-3630-304a57544254","type":"sas"},{"id":"EO001600JWTCB","target_guid":"452340a5-304f-3130-3630-304a57544342","type":"sas"},{"id":"VO000960JWTBK","target_guid":"562340a5-304f-3030-3936-304a5754424b","type":"sas"},{"id":"MO000800JWTBR","target_guid":"4d2340a5-304f-3030-3830-304a57544252","type":"sas"},{"id":"EO000800JWTCA","target_guid":"452340a5-304f-3030-3830-304a57544341","type":"sas"},{"id":"MO000400JWTBQ","target_guid":"4d2340a5-304f-3030-3430-304a57544251","type":"sas"},{"id":"EO000400JWTBV","target_guid":"452340a5-304f-3030-3430-304a57544256","type":"sas"},{"id":"MO001920JWWWV","target_guid":"4d2340a5-304f-3130-3932-304a57575756","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T19:48:38","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Change Vendor Identification Field (VID data) from &quot;HP&quot; to &quot;HPE&quot;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EO000400JWTBV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001920JWWWV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920JWTBL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600JWTBT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO001600JWTCB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000800JWTCA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800JWTBR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000960JWTBK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO007680JWTBP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200JWTBU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO006400JWTCD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000400JWTBQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003840JWTBN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO003200JWTCC","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the iSCSI driver for the HPE Emulex 10/20Gb Server Adapters for Windows Server 2012 R2."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Windows Server 2012 R2用のHPE Emulex 10/20GbサーバーアダプターのiSCSIドライバー を含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"905896","datemodified":"2020-06-12T07:09:59","file_list":["be2iscsi.cat","be2iscsi.inf","be2iscsi.sys","bepiscsi.dll","cp044560.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"md5sum":"6ce9db856b1883f680f1c0920815a62c","name":"cp044560.exe","release":"2020-06-12T06:56:07","revision":"0","sha1sum":"505dc1b5af7bb4b6589b7cf89e3977449f7b9bd6","size":"884KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec037c8524"],"type_of_change":"0","version":"12.0.1171.0"}],"id":{"product":"273329c7dcda48fbb886f52e82f63064","version":"1f9a78a521804f5081b7834970c35cd9"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex 10/20 GbE iSCSI Driver for Windows Server 2012 R2"},{"lang":"ja","x_late":"HPE Emulex 10/20 GbE iSCSIドライバー for Windows Server 2012 R2"}],"prerequisites":{"required_diskspace":{"size_kb":"320"},"supported_devices":[{"dev":"0722","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c220a","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c21d4","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c8144","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072215908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-12T06:00:10","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now remove&nbsp;supports Synergy and Blade&nbsp;Server.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p style=\"text-align:left\">This product now supports the following network adapters:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"}],"sw_keys":[{"name":"be2iscsi.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware for Mezzanine Converged Network adapters."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"7580336","datemodified":"2021-09-14T07:56:46","file_list":["brcmflashStandalone-windows-12.0.1345.0-1/firmware/","brcmflashStandalone-windows-12.0.1345.0-1/firmware/oc14-12.0.1345.0.ufi","brcmflashStandalone-windows-12.0.1345.0-1/win/","brcmflashStandalone-windows-12.0.1345.0-1/win/brcmflash.bat","brcmflashStandalone-windows-12.0.1345.0-1/win/brcmwinlpcfg.bat","brcmflashStandalone-windows-12.0.1345.0-1/win/x64/","brcmflashStandalone-windows-12.0.1345.0-1/win/x64/brcmflash.exe","brcmflashStandalone-windows-12.0.1345.0-1/win/x64/BrcmMILI.dll","brcmflashStandalone-windows-12.0.1345.0-1/win/x64/brcmwinlpcfg.exe","brcmflashStandalone-windows-12.0.1345.0-1/win/x64/firmware/","brcmflashStandalone-windows-12.0.1345.0-1/win/x64/libbrcmdfc.dll","brcmflashStandalone-windows-12.0.1345.0-1/win/x64/RM.INI","cp048528.xml","cpqsetup.exe","fwmatrix.txt","brcmflashStandalone-windows-12.0.1345.0-1/win/x64/fwmatrix.txt","hpe_fw_matrix.xml","installer.dll","payload.json","readme.txt","brcmflashStandalone-windows-12.0.1345.0-1/win/x64/readme.txt","reference.xml"],"md5sum":"af0241502cbfec7269540f6063e76896","name":"cp048528.exe","release":"2021-09-14T07:42:22","revision":"0","sha1sum":"18e6733d95c02446792b13f38877c5dbc1ef2bb7","size":"7MB","target_guids":[],"type_of_change":"1","version":"2021.10.01"}],"id":{"product":"ea8cfb710123468d8a16d7b3f1f1d2df","version":"8f44507f9aea44afbe8208589168a558"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p dir=\"LTR\">Download the Smart Component to a directory on your hard drive and change to that directory.</p>\n\n<p>The downloaded file is a self-extracting executable with a filename based on the Component Number.<br />\nFrom that drive and directory, execute the downloaded file.<br />\n<br />\nClick the &quot;Install&quot; button to proceed with the installation.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Firmware Flash for Emulex Mezzanine Converged Network Adapters for Microsoft Windows Server 2016/2019(x64)"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"0724","subdev":"1935","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1935","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1934","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"1934","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T10:38:38","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p dir=\"LTR\">We&nbsp;have separate components to update fibre channel and converged network adapters.&nbsp; This is a converged network adapter update component.<br />\n<br />\nUpdated CNA (XE100 series) firmware&nbsp;</p>\n\n<p>This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 20Gb 2-port 650FLB Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1345.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 20Gb 2-port 650M Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1345.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"emulex_cna","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This component contains the driver for HPE Broadcom NetXtreme-E devices for Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージには、Windows Server 2019用HPE Broadcom NetXtreme-Eデバイスのドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1026624","datemodified":"2021-01-14T07:14:35","file_list":["bnxtnd.cat","bnxtnd.inf","bnxtnd.sys","cp045021.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"md5sum":"0b4e87269f0b0842d74425c0733cf7ea","name":"cp045021.exe","release":"2021-01-14T06:59:05","revision":"0","sha1sum":"c7917e0657fba322d32c6cd645a36aecafedf7c9","size":"0MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec919626a4"],"type_of_change":"0","version":"218.0.32.0"}],"id":{"product":"dd64dbafe6064086a1f60841a460f8b0","version":"adc9ee2cc1df4db187d5224df9c5b239"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the \"Install\" button to proceed with the installation."},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>［インストール］ボタンをクリックして、インストールを開始します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E Driver for Windows Server 2019"},{"lang":"ja","x_late":"HPE Broadcom NetXtreme-E ドライバー for Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"600"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This product correct an issue which live firmware upgrade fails when run on both interfaces of the adapter simultaneously.</li>\n\t<li>This product corrects a timeout issue which configures network connection.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product correct an issue where an system are freeze and reboot when system recovering after non-fatal error.</li>\n\t<li>This product correct an issue which fixes BSOD observed after updating the inbox driver on Windows 2019.</li>\n\t<li>This product correct an issue which fixes VF will not load on certain Virtual OS when Windows is host OS.&nbsp;</li>\n\t<li>This product correct an issue which fixes user mode RDMA blue screen of death (BSoD) caused by an IRP SystemBuffer access race condition</li>\n\t<li>This product corrects a Windows Stop Error blue screen of death (BSoD) seen when uninstalling the NDIS driver.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"bnxtnd.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built for Red Hat Enterprise Linux 7 (64-bit) to enable the HPE Smart Array B140i SATA RAID controller."},{"lang":"ja","x_late":"このRPMを使用して、HPE Smart Array B140i SATA RAIDコントローラーを有効にする、Red Hat Enterprise Linux 7（64-bi）用のビルド済みバイナリドライバーモジュールを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[],"files":[{"bytes":"912619","datemodified":"2021-05-28T07:49:33","file_list":["./etc/depmod.d/hpdsa.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/hpdsa","./lib/modules/3.10.0-1127.el7.x86_64/extra/hpdsa/hpdsa.ko","./usr/share/smartupdate/kmod-hpdsa/component.xml"],"md5sum":"c1fd884b959fc9545e6075d8c0b12edc","name":"kmod-hpdsa-1.2.10-196.rhel7u8.x86_64.rpm","release":"2021-05-28T07:41:05","revision":"0","sha1sum":"4d972f3a5bd09c76874219e22076a3f072926e45","size":"891KB","target_guids":[],"type_of_change":"1","version":"1.2.10-196"},{"bytes":"912611","datemodified":"2021-05-28T07:51:09","file_list":["./etc/depmod.d/hpdsa.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/hpdsa","./lib/modules/3.10.0-1160.el7.x86_64/extra/hpdsa/hpdsa.ko","./usr/share/smartupdate/kmod-hpdsa/component.xml"],"md5sum":"0ecc2ed2c652c7bad0723871a986efa8","name":"kmod-hpdsa-1.2.10-196.rhel7u9.x86_64.rpm","release":"2021-05-28T07:41:05","revision":"0","sha1sum":"d0b6d213e3941dd07c89b7ff2a6db156cd5ae8c2","size":"891KB","target_guids":[],"type_of_change":"1","version":"1.2.10-196"}],"id":{"product":"45de3d94e74d43a1ad4f5b8b01de0092","version":"2fb3f77e53e6450c9e037784a7087b8f"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as the system administrator (root), download the RPM to a directory on<br />\nyour hard drive and change to that directory.</p>\n\n<p dir=\"ltr\"><strong>To install&nbsp;or&nbsp;upgrade&nbsp;the driver type:</strong></p>\n\n<p># rpm -Uvh kmod-hpdsa-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</p>\n\n<p>Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p dir=\"ltr\">NOTE: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:</p>\n\n<p dir=\"ltr\"># rpm -e kmod-hpdsa-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</p>\n\n<p dir=\"ltr\">&nbsp;</p>\n\n<p dir=\"ltr\"><strong><u>Enterprise Support</u></strong><br />\nFor support on Smart Array controllers, visit&nbsp;<a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a></p>\n"},{"lang":"ja","x_late":"<p>システム管理者（root）としてログインし、RPMを<br />\nご使用のハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</p>\n\n<p dir=\"ltr\"><strong>ドライバーをインストールまたはアップグレードするには次のようにタイプします。</strong></p>\n\n<p># rpm -Uvh kmod-hpdsa-<version>.<OSupdate>.x86_64.rpm</p>\n\n<p>Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p dir=\"ltr\">注：インストールの失敗、あるいは警告やエラーメッセージを表示して停止した場合は、コンピューターを再起動しないでください。ドライバーは動作しないため、以下のコマンドをタイプしてアンインストールしてください。</p>\n\n<p dir=\"ltr\"># rpm -e kmod-hpdsa-<version>.<OSupdate>.x86_64.rpm</p>\n\n<p dir=\"ltr\"> </p>\n\n<p dir=\"ltr\"><strong><u>Enterprise Support</u></strong><br />\nエンタープライズサポートSmartアレイコントローラーのサポートに関しては <a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a>を参照してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Dynamic Smart Array B140i SATA RAID Controller Driver for Red Hat Enterprise Linux 7 (64-bit)"},{"lang":"ja","x_late":"Red Hat Enterprise Linux 7（64-bit）用HPE Dynamic SmartアレイB140i SATA RAIDコントローラードライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"8D06","subdev":"009C","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"8D66","subdev":"009D","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"193F","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"A106","subdev":"00C0","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"A107","subdev":"00C0","subven":"1590","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T07:05:05","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Add support for Red Hat Enterprise Linux 7 Update 9</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Add support for Red Hat Enterprise Linux 7 Update 9</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U25","value":"HP ProLiant XL280d Accelerator Tray - cancelled"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"kmod-hpdsa","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hpdsa","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hpdsa","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hpdsa","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE 12Gb SAS Expander Card","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"firmware-Signed-5.10-build-000.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","Version":"5.10"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"Supplemental Update / Online ROM Flash Smart Component which upgrades the enclosure firmware on HPE ProLiant Gen9 expanders"},{"lang":"cn","x_late":"可升级 HPE ProLiant Gen9 扩展卡上机柜固件的补充更新/在线 ROM Flash 智能组件"},{"lang":"tw","x_late":"補充更新/線上 ROM 更新智慧型元件，可升級 HPE ProLiant Gen9 擴充的機櫃韌體"},{"lang":"ko","x_late":"추가 업데이트/HPE 프로라이언트 Gen9 확장기에서 인클로저 펌웨어를 업그레이드하는 온라인 ROM 플래시 스마트 구성 요소"},{"lang":"ja","x_late":"HPE ProLiant Gen9エキスパンダー上のエンクロージャーファームウェアをアップグレードするサプリメンタルアップデート / オンラインROMフラッシュSmartコンポーネント"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n<strong>&nbsp; &nbsp; &nbsp;</strong>Online ROM Flash Component for Linux &ndash; HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;5.10<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 5.09<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; 4.22<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>N/A</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Valid flag is always set to true initially so that CRC check can be performed on initstring partition and test if it is really valid.</li>\n\t<li>Move Smart Carrier Authentication to later in the boot process and move the Exception Dumper task to earlier in the process in order to support Winbond alternative Flash</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"},{"lang":"ja","x_late":"<p><strong>提供名：</strong><br />\n<strong>     </strong>オンラインROMフラッシュコンポーネント for Linux - HPE 12Gb/s SASエキスパンダーファームウェア for HPE SmartアレイコントローラーおよびHPE HBAコントローラー</p>\n\n<p><strong>リリースバージョンおよび/または日付:</strong><br />\n     5.10<br />\n<br />\n<strong>最新の推奨またはクリティカルバージョン：</strong><br />\n     5.09<br />\n<br />\n<strong>以前のファームウェアバージョン：</strong><br />\n     4.22<br />\n<br />\n<strong>ファームウェアmoの関連性:</strong><br />\n     なし  <br />\n<br />\n<strong>改善点/新しい機能：</strong></p>\n\n<ul>\n\t<li>N/A    </li>\n</ul>\n\n<p><strong>修正された問題：</strong></p>\n\n<ul>\n\t<li>有効なフラグは最初は常にtrueに設定されているため、initstringパーティションでCRCチェックを実行し、それが本当に有効かどうかをテストできます。</li>\n\t<li>Winbondの代替フラッシュをサポートするために、スマートキャリア認証をブートプロセスの後半に移動し、Exception Dumperタスクをプロセスの前半に移動してください</li>\n</ul>\n\n<p><strong>既知の問題点:</strong><br />\n     なし        </p>\n"}],"files":[{"bytes":"5400997","datemodified":"2021-08-16T10:52:17","file_list":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.10-1.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.10-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.10-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.10-1.1/CP049278.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.10-1.1/firmware-Signed-5.10-build-000.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.10-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.10-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.10-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.10-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049278.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049278.scexe"],"md5sum":"6a70622927fd8542d10ec407714e6e89","name":"firmware-smartarray-1f19a4a64d-5.10-1.1.x86_64.rpm","release":"2021-09-06T00:00:00","revision":"1","sha1sum":"4462667ddd38a072b4e2e69dc3883d93c6822306","size":"5MB","target_guids":["b99dfb74-f0bc-464f-b418-cd18c097d8f0"],"type_of_change":"1","version":"5.10"}],"id":{"product":"799e6d2dd6574724a67dc3ea392d2873","version":"3ff61e3731cf4c93801a985bb964793a"},"installation":{"command":"CP049278.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><u>Power cycle/ cold reboot is required if firmware is upgraded from version 1.31 or earlier.</u></p>\n\n<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong><em>Updating firmware with rpm installed:</em></strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li>\n\t<li>The CP044963.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-2de15b6882-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above&nbsp;</li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./ CP044963.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-2de15b6882-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><strong><em>Updating firmware without installing the rpm:</em></strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-2de15b6882-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-2de15b6882-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li>\n\t<li>Run launch_sum.sh script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><u>ファームウェアがバージョン1.31またはそれ以前からアップグレードされた場合には、電源再投入/コールドリブートが必要です。</u></p>\n\n<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p><strong><em>rpmインストールによるファームウェアのアップデート:</em></strong></p>\n\n<ul>\n\t<li>コマンドを使用して、ファームウェアrpmをインストールします:  <em>rpm -ivh <rpm_filename>。  </em>これは、'/usr/lib/x86_64-linux-gnu' の場所へrpmの内容を解凍します。</li>\n\t<li>CP044963.scexeスクリプトは 'scexe-compat'フォルダーにあります。'firmware-smartarray-2de15b6882-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>./ CP044963.scexe（'/usr/lib/x86_64-linux-gnu/scexe-compat'で実行）（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-smartarray-2de15b6882-*' にある<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド: <em>rpm -e <rpm_package_name></em>（'.rpm' 拡張子の付いていないrpmファイル名）を実行します。</li>\n</ul>\n\n<p><strong><em>rpmのインストールなしでのファームウェアのアップデート：</em></strong></p>\n\n<ul>\n\t<li>rpmの内容を次のコマンドを用いて抽出します。 <em>rpm2cpio <rpm_filename>.rpm | cpio -id.  </em>これは、現在のディレクトリの‘usr’フォルダーへrpmの内容を抽出します。</li>\n\t<li>'usr/lib/x86_64-linux-gnu/firmware-smartarray-2de15b6882-*'に移動し、ファームウェアをアップデートするために<em>./setup</em>を実行します。'firmware-smartarray-2de15b6882-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p><strong><em>追加情報：</em></strong></p>\n\n<p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant</u></a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/SPP20xxxxx/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートに必要なファームウェアをSPP20xxxxx/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにあるlaunch_sum.shスクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Supplemental Update / Online ROM Flash Component for Linux (x64) – HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers"},{"lang":"cn","x_late":"Linux (x64)版补充更新/在线ROM刷新组件 – 适用于HPE智能阵列控制器和HPE HBA控制器的HPE 12Gb/s SAS扩展器固件"},{"lang":"tw","x_late":"適用於 Linux (64) 的補充更新/線上 ROM 更新元件 – 適用於 HPE Smart Array 控制器和 HPE HBA 控制器的 HPE 12Gb/s SAS 擴充韌體"},{"lang":"ko","x_late":"Linux(x64)용 추가 업데이트/온라인 ROM 플래시 구성 요소 - HPE 스마트 어레이 컨트롤러 및 HPE HBA 컨트롤러용 HPE 12Gb/s SAS 익스팬더 펌웨어"},{"lang":"ja","x_late":"サプリメンタルアップデート/オンラインROMフラッシュコンポーネント for Linux (x64) - HPE 12 Gb/s SASエキスパンダーファームウェア for HPE SmartアレイコントローラーおよびHPE HBAコントローラー"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-10-07T07:17:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>To make Valid flag is always set to true initially so that CRC check can be performed on initstring partition and test if it is really valid.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Valid flag is always set to true initially so that CRC check can be performed on initstring partition and test if it is really valid.</li>\n\t<li>Move Smart Carrier Authentication to later in the boot process and move the Exception Dumper task to earlier in the process in order to support Winbond alternative Flash</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"12G SAS Exp Card","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]},{"key":"7800374","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"en","x_late":"This package contains utilities and libraries to enable HPE Storage fibre channel over Ethernet array connectivity on SUSE Linux Enterprise Server 15 for Emulex Host Bus Adapters and Mezzanine Host Bus Adapters."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1638475","datemodified":"2021-08-27T06:15:10","file_list":["./opt/broadcom/sles15sp2/i386/lib/libbrcmdfc.so","./opt/broadcom/sles15sp2/i386/lib/libbrcmdfc.so.12","./opt/broadcom/sles15sp2/i386/lib/libbrcmdfc.so.12.0.1329","./opt/broadcom/sles15sp2/i386/lib/libbrcmemsdm.so","./opt/broadcom/sles15sp2/i386/lib/libbrcmhbaapi.so","./opt/broadcom/sles15sp2/x86_64/lib64/libbrcmdfc.so","./opt/broadcom/sles15sp2/x86_64/lib64/libbrcmdfc.so.12","./opt/broadcom/sles15sp2/x86_64/lib64/libbrcmdfc.so.12.0.1329","./opt/broadcom/sles15sp2/x86_64/lib64/libbrcmemsdm.so","./opt/broadcom/sles15sp2/x86_64/lib64/libbrcmhbaapi.so","./usr/lib/libbrcmdfc.so","./usr/lib/libbrcmdfc.so.12","./usr/lib/libbrcmdfc.so.12.0.1329","./usr/lib/libbrcmemsdm.so","./usr/lib/libbrcmhbaapi.so","./usr/lib64/libbrcmdfc.so","./usr/lib64/libbrcmdfc.so.12","./usr/lib64/libbrcmdfc.so.12.0.1329","./usr/lib64/libbrcmemsdm.so","./usr/lib64/libbrcmhbaapi.so","./usr/share/smartupdate/HPE-CNA-FC-Broadcom-Enablement-Kit/component.xml"],"md5sum":"8ed1b0e2ff3f521a0792d0027387ab20","name":"HPE-CNA-FC-Broadcom-Enablement-Kit-12.0.1339.0-1.sles15sp2.x86_64.rpm","release":"2021-08-27T06:09:07","revision":"0","sha1sum":"1efc37774f89660f563339c0a4c4566ae7a7036f","size":"1MB","target_guids":[],"type_of_change":"1","version":"12.0.1339.0"}],"id":{"product":"81c01fe9fbb448c4845fa214dfcef6a1","version":"26343230776a43be86bf1d39f9732beb"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>There has been a change to the enablement kits in this release.&nbsp; They are now vendor specific kits.&nbsp;&nbsp; It is recommended that you uninstall any previous kits prior to installation of this component.<br />\n<br />\nTo uninstall the hp-fc-enablement RPM use the following command:</p>\n\n<p>&nbsp;&nbsp; # rpm -e hp-fc-enablement-&lt;version&gt;.noarch.rpm<br />\n<br />\nTo install the hp-CNA-fc-enablement RPM use the following command:</p>\n\n<p>&nbsp;&nbsp; # rpm -ivh HP-CNA-FC-Broadcom-Enablement-Kit-&lt;version&gt;.&lt;OS&gt;.&lt;architecture&gt;.rpm<br />\n<br />\nThis version of the enablement kit does not provide the additional functionality of rebuilding the ram disk or setting driver parameters as the previous versions had done.&nbsp; Please refer to the &ldquo;Additional setup&rdquo; section of the Native Linux Device-Mapper Multipath for HPE StorageWorks Arrays reference guide for instructions on how to perform these functions.&nbsp; The reference guide is available at the following link:<br />\n&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; <a href=\"http://www.hpe.com/storage/spock/\">http://www.hpe.com/storage/spock/</a><br />\n&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex(BRCM) Fibre Channel Over Ethernet Enablement Kit for Host Bus Adapters and Mezzanine Host Bus Adapters for SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T11:01:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to version: 12.0.1339.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"}],"sw_keys":[{"name":"HPE-CNA-FC-Broadcom-Enablement-Kit","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 adapter cards."},{"lang":"ja","x_late":"このRPMには、サポートされているHPE Mellanox ConnectX-4、ConnectX-5、およびConnectX-6アダプターカード用のHPEによるテストと承認済みのLinuxベースMellanox RoCE（RDMA over Converged Ethernet）ドライバーが含まれます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1303008","datemodified":"2021-07-20T16:50:14","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/rdma","./etc/rdma/mlx4.conf","./etc/rdma/modules","./etc/rdma/modules/rdma.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/70-persistent-ipoib.rules","./lib/udev/auxdev-sf-netdev-rename","./lib/udev/mlnx_bf_udev","./lib/udev/rules.d/82-net-setup-link.rules","./lib/udev/rules.d/83-mlnx-sf-name.rules","./lib/udev/rules.d/90-ib.rules","./lib/udev/sf-rep-netdev-rename","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/mlnx_bf_configure_ct","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_perf","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/include/mellanox/dpcp.h","./usr/lib/dracut","./usr/lib/dracut/modules.d","./usr/lib/dracut/modules.d/05rdma","./usr/lib/dracut/modules.d/05rdma/module-setup.sh","./usr/lib/modprobe.d","./usr/lib/modprobe.d/libmlx4.conf","./usr/lib/python2.7/site-packages/dcbnetlink.py","./usr/lib/python2.7/site-packages/genetlink.py","./usr/lib/python2.7/site-packages/mlnx_tools-5.2.0-py2.7.egg-info","./usr/lib/python2.7/site-packages/netlink.py","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/rdma-ndd.service","./usr/lib/systemd/system/vma.service","./usr/lib/udev/rdma_rename","./usr/lib/udev/rules.d","./usr/lib/udev/rules.d/60-rdma-ndd.rules","./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules","./usr/lib/udev/rules.d/75-rdma-description.rules","./usr/lib/udev/rules.d/90-rdma-umad.rules","./usr/lib64/libdpcp.so","./usr/lib64/libdpcp.so.1","./usr/lib64/libdpcp.so.1.1.12","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.35.0","./usr/lib64/libibverbs","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.14.35.0","./usr/lib64/libibverbs/libmlx5-rdmav34.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.19.35.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.3.35.0","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.3.1","./usr/lib64/rsocket","./usr/lib64/rsocket/librspreload.so","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/libexec/mlx4-setup.sh","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/ibdev2netdev","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/rdma-ndd","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vmad","./usr/share/doc/dpcp-1.1.12","./usr/share/doc/dpcp-1.1.12/README","./usr/share/doc/libibverbs-54mlnx1","./usr/share/doc/libibverbs-54mlnx1/libibverbs.md","./usr/share/doc/librdmacm-54mlnx1","./usr/share/doc/librdmacm-54mlnx1/librdmacm.md","./usr/share/doc/libvma-9.3.1","./usr/share/doc/libvma-9.3.1/CHANGES","./usr/share/doc/libvma-9.3.1/README","./usr/share/doc/mlnx-tools-5.2.0","./usr/share/doc/mlnx-tools-5.2.0/ib2ib_setup.txt","./usr/share/doc/rdma-core-54mlnx1","./usr/share/doc/rdma-core-54mlnx1/COPYING.BSD_FB","./usr/share/doc/rdma-core-54mlnx1/COPYING.BSD_MIT","./usr/share/doc/rdma-core-54mlnx1/COPYING.GPL2","./usr/share/doc/rdma-core-54mlnx1/COPYING.md","./usr/share/doc/rdma-core-54mlnx1/README.md","./usr/share/doc/rdma-core-54mlnx1/tag_matching.md","./usr/share/doc/rdma-core-54mlnx1/udev.md","./usr/share/licenses/dpcp-1.1.12","./usr/share/licenses/dpcp-1.1.12/LICENSE","./usr/share/licenses/libvma-9.3.1","./usr/share/licenses/libvma-9.3.1/COPYING","./usr/share/man/man7/rsocket.7.gz","./usr/share/man/man7/vma.7.gz","./usr/share/man/man8/ib2ib_setup.8.gz","./usr/share/man/man8/rdma-ndd.8.gz","./usr/share/man/man8/vmad.8.gz","./usr/share/mlnx_ofed/mlnx_bf_assign_ct_cores.sh","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml","./usr/lib/python2.7/site-packages/dcbnetlink.pyc","./usr/lib/python2.7/site-packages/dcbnetlink.pyo","./usr/lib/python2.7/site-packages/genetlink.pyc","./usr/lib/python2.7/site-packages/genetlink.pyo","./usr/lib/python2.7/site-packages/netlink.pyc","./usr/lib/python2.7/site-packages/netlink.pyo"],"md5sum":"182570aeef2936bc5b74d4f7b48f4029","name":"mlnx-ofa_kernel-5.4-OFED.5.4.1.0.3.1.rhel7u9.x86_64.rpm","release":"2021-07-20T15:41:06","revision":"0","sha1sum":"80d8cc1183e5aa5ccb04831ffd3f684cd3ec00d2","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81"],"type_of_change":"1","version":"5.4"},{"bytes":"1334341","datemodified":"2021-07-20T16:56:08","file_list":["./etc/depmod.d/zz01-mlnx-ofa_kernel-auxiliary.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-bnxt_re.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-efa.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-hfi1.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-i40iw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ipath.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ipoib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_iser.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_isert.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_mthca.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_qib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srp.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srpt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_umad.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_uverbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cxgb3.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cxgb4.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_nes.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx_compat.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxfw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvme-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvmet-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ocrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-opa_vnic.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-qedr.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_rxe.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdmavt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rpcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-svcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-usnic_verbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-vmw_pvrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-xprtrdma.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/compat","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/compat/mlx_compat.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/base","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/base/auxiliary.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_cm.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_core.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_ucm.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_umad.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/iw_cm.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_cm.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb3","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb3/iw_cxgb3.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa/efa.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/i40iw","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ipath","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ipath/ib_ipath.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mthca","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mthca/ib_mthca.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/nes","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/nes/iw_nes.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ocrdma","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ocrdma/ocrdma.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qib","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qib/ib_qib.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host/nvme-rdma.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/net","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/kmod-mlnx-ofa_kernel/component.xml"],"md5sum":"22b152dc5fd30223a6ea6ae255abcc59","name":"kmod-mlnx-ofa_kernel-5.4-OFED.5.4.1.0.3.1.rhel7u9.x86_64.rpm","release":"2021-07-20T15:41:06","revision":"0","sha1sum":"ed1b069aa21d03be9ee451c1c82946a08405bd6a","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81"],"type_of_change":"1","version":"5.4"}],"id":{"product":"ac732738370b4df180761b2b7435b65d","version":"1884180b863f46c68a9c67722e3fffdc"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)","OSVersion":{"name":"Linux","value":"6.9"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)","OSVersion":{"name":"Linux","value":"6.10"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)","OSVersion":{"name":"Linux","value":"7.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)","OSVersion":{"name":"Linux","value":"7.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-5.4&quot;&nbsp;RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.&nbsp;<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using kernel version 3.10.0-1160.el7&nbsp;or any future errata:<br />\n<br />\n<strong># rpm -Uvh&nbsp;kmod-mlnx-ofa_kernel-5.4-OFED.5.4-0.5.1.1.rhel7u9.x86_64.rpm mlnx-ofa_kernel-5.4-OFED.5.4-0.5.1.1.rhel7u9.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 Adapters for Red Hat Enterprise Linux 7 Update 9 (x86_64)"},{"lang":"ja","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) ドライバーfor Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 Adapters for Red Hat Enterprise Linux 7 Update 9 (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"101f","subdev":"0012","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30012","type":"pci","ven":"15b3"},{"dev":"101f","subdev":"0007","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30007","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"032D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-10171590032d","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T17:11:49","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Changes and new features in HPE Mellanox RoCE driver&nbsp;version 5.2:</strong></p>\n\n<p><strong>For ConnectX-5 Adapters and above:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>CQE compression support for Rx multi-strides packets.</li>\n\t\t<li>Configuring QoS on a single QP or on a group of QPs.</li>\n\t\t<li>Encap/decap hardware offload of IPv4 traffic over MPLS-over-UDP. This can be used in networks with MPLS routers to achieve more efficient routing.</li>\n\t\t<li>Connection tracking rules on VFs to forward traffic from one VF to the other.</li>\n\t\t<li>Offloading sFlow sampling rules.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For ConnectX-5 Adapters and ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>A locking mechanism to enable parallel insertion of rules into the software steering using the mlx5dv_dr API. The parallel insertion improves the insertion rate and takes place when adding Rx and Tx rules via the FDB domain.</li>\n\t\t<li>Option to match mlx5dv_dr API on Geneve tunnel using a dynamic flex parser. The option header consists of class, type, length and data. The parser should be configured using devx command, after which a rule can be created to match on parser ID and data.</li>\n\t\t<li>Geneve tunneling offload, including matching on extension header.</li>\n\t\t<li>Parallel insertion and deletion of offloaded rules using multiple&nbsp;OVS threads.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>[Beta] Modify GTP-U TEID. This support requires flex parser&nbsp;configuration.</li>\n\t\t<li>[Beta] Improved performance of OVS Connection Tracking flows by&nbsp;enabling the merge of the multi-table flow matches and actions into one joint flow.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Dx Adapters and above:</strong></p>\n\n<p>Added support for the following features:</p>\n\n<ul>\n\t<li>Transmitted packet timestamping accuracy can be improved when using a timestamp generated at the port level instead of a timestamp generated upon CQE creation. Tx port time-stamping better reflects the actual time of a packet&#39;s transmission. This feature is disabled by default. The feature can be enabled or disabled using the following command. ethtool --set-priv-flags tx_port_ts on / off.</li>\n\t<li>Offloading tunnel rules when the source interface is VF (in addition to uplink) in the Hypervisor.</li>\n\t<li>Using Mirroring Offload with Connection Tracking.</li>\n\t<li>ASO flow meter using the mlx5dv_dr API, which allows for monitoring the packet rate for specific flows. When a packet hits a flow that is connected to a flow meter, the rate of packets through this meter is evaluated, and the packet is marked with a color copied into one of the C registers, according to the current rate compared to the reference rate.</li>\n\t<li>ASO first hit using the mlx5dv_dr API, which allows for tracking rule hits by packets. When a packet hits a rule with the ASO first hit action, a flag is set indicating this event, and the original value of the flag is copied to one of the C registers.</li>\n\t<li>mlx5dv_dr API support for matching on a new field &quot;gtpu_first_ext_dw_0&quot;. This field enables packet filtering based on the GTP-U first extension header (first dword only). To enable parsing of tunnel GTP-U extension header, run the following command. ./cloud_fw_reset.py FLEX_PARSER_PROFILE_ENABLE=3.</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Lx Adapters and above:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>IPsec full offload support for extended sequence number, replay protection window and lifetime packet limit.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;All HCA&#39;s:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>New query GID API that allows for querying a single GID entry by its port and GID index, or querying for all GID tables of a specific device. This API works over ioctl instead of sysfs, which accelerates the querying process.</li>\n\t\t<li>Performing multi-host firmware reset in order to upgrade the device firmware. Firmware reset loads the new firmware in case it was burnt on the flash and was pending activation, and reload.</li>\n\t\t<li>[Alpha] Firmware live patching in the driver. Live patching updates the firmware without the need to perform firmware reset. However, it can only be applied in scenarios where the difference between the current and new firmware versions are minor, which is decided upon by the firmware itself.</li>\n\t\t<li>devlink tool for performing firmware reset in order to upgrade the device firmware. Firmware reset loads the new firmware in case it was burnt on the flash and was pending activation, and reloads the current firmware image from the flash in case no new firmware was pending. For further information, please refer to the the devlink man page.</li>\n\t\t<li>A resiliency mechanism for the driver to manually poll the command event queue (EQ) in case of a command timeout. In case the resiliency mechanism finds unhandled event queue entry (EQE) due to a lost interrupt, the driver will handle it, after which the command interface returns to a healthy state.</li>\n\t\t<li>Setting a sniffer private flag is deprecated and no longer required. In order to capture offloaded/RoCE traffic, tcpdump can now be run on the RDMA device.</li>\n\t\t<li>Added per-port reporters to devlink health to manage per-port health activities. Users can now access the devlink port reporters by specifying the port index in addition to the device devlink name through the devlink health commands API. This update was first introduced in iproute2 v5.8. As part of this feature, mlx5e Tx and Rx reporters are now redefined as devlink port reporters. For examples, please see devlink-health manpage</li>\n\t\t<li>Optimized memory consumption of memory registration in huge page systems. As an example, in a 2MB huge page system, 600 MB would be saved for 100 GB memory registration.</li>\n\t\t<li>mlx5dv API to modify the configured UDP source port for RoCE packets of a given RC/UC QP when QP is in RTS state.</li>\n\t\t<li>Accelerating Tx datapath by saving PCI bandwidth and CPU utilization. The savings are achieved by aggregating multiple packets into a single WQE. The feature is driven by xmit_more for certain traffic types, such as UDP.</li>\n\t</ul>\n\t</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 5.2:</strong></p>\n\n<ul>\n\t<li>Clearing min_rate on all SR-IOV legacy VFs after setting min_rate to at least one of the VFs did not disable QoS min_rate.</li>\n\t<li>An empty /usr/src/mlnx-ofa_kernel/default is now no longer created.</li>\n\t<li>An issue where installing packages through a repository failed after generation of metapackages using --add-kernel-support. The failure occurred due to excessive and incorrect Obsolete headers in those metapackages.Enabled installation of mlnx-ofa_kernel package to /bin/python3 instead of / usr/bin/python3 on RHEL 8.x systems.</li>\n\t<li>All IPoIB offload packets were wrongly counted as rx_csum_complete. These packets are now identified as rx_csum_unnecessary packets.</li>\n\t<li>mlx5dv_dr_rule_destroy segmentation fault could happen in rare cases with multiple rules on the same matcher with a different number of actions. This could happen after reusing an already deleted rule memory with less actions.</li>\n\t<li>An issue of moving to SwitchDev mode after configuring DSCP (Differentiated Service Code Point).</li>\n\t<li>Global traffic class configuration did not take effect on DC QPs (Dynamically Connected Queue Pairs).</li>\n\t<li>ib_send_bw traffic frequently dropped to zero when RDMA CM was used, because of incorrect&nbsp;min_rnr_timer setting on the responder side. The min_rnr_timer setting is now aligned with the setting in non-RDMA CM cases.</li>\n\t<li>Traffic did not pass over VFs with VST QinQ feature is enabled.</li>\n\t<li>When traffic was sent over Geneve VLAN with Tx VLAN offload enabled and TSO (TCP Segmentation Offload)&nbsp;or Tx csum enabled, traffic could be dropped and not sent to the wire.</li>\n\t<li>An issue that caused the firmware to restart upon installing mlnxofed-dpdk-upstream-libs package manually.</li>\n\t<li>Bad utility paths in rdma-core &quot;dracut&quot; hooks on SLES systems, which used to result in the following errors when running &quot;dracut&quot; with the &quot;--add rdma&quot; option. dracut-install:\n\t<ul>\n\t\t<li>ERROR: installing &lsquo;/usr/libexec/mlx4-setup.sh&rsquo; dracut: /usr/lib/dracut/dracut-install -D /var/tmp/dracut.UdCOSJ/ initramfs /usr/libexec/mlx4-setup.sh dracut-install: ERROR: installing &lsquo;/usr/libexec/rdma-set-sriov-vf&rsquo; dracut: /usr/lib/dracut/dracut-install -D /var/tmp/dracut.UdCOSJ/ initramfs /usr/libexec/rdma-set-sriov-vf</li>\n\t</ul>\n\t</li>\n\t<li>Traffic class value was not updated in DCT when set via sysfs.</li>\n\t<li>A doorbell loss issue on AMD platforms with Secure Memory Encryption (SME).</li>\n\t<li>Registering memory using mlx5dv_devx_umem_reg while forking. Without this fix, applications which use fork() or similar syscalls while using a memory registered with umem_reg could hang due to incorrect physical page mapping. This fix requires setting the IBV_FORK_SAFE environment variable.</li>\n\t<li>When&nbsp;unbinding the device resulted in the following message being printed to the dmesg: &quot;failed to disable DC tracer&quot;</li>\n\t<li>Content of file /sys/class/net//statistics/ multicast might have been out of date and might have displayed values lower than the real values.</li>\n\t<li>ERSPAN (Encapsulated Remote SPAN) protocol was available only when turning off Tx checksum offload.</li>\n\t<li>A udev script issue which caused non-mellanox devices to be renamed.</li>\n\t<li>Missing representor statistics when using ifconfig.</li>\n\t<li>Fixed wrong value of skb mark of received packets on representors.</li>\n\t<li>An issue which caused second port representors to be named as first port representors.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Changes and new features in HPE Mellanox RoCE driver&nbsp;version 5.3:</strong></p>\n\n<p><strong>For ConnectX-5 Adapters and above:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>CQE compression support for Rx multi-strides packets.</li>\n\t\t<li>Configuring QoS on a single QP or on a group of QPs.</li>\n\t\t<li>Encap/decap hardware offload of IPv4 traffic over MPLS-over-UDP. This can be used in networks with MPLS routers to achieve more efficient routing.</li>\n\t\t<li>Connection tracking rules on VFs to forward traffic from one VF to the other.</li>\n\t\t<li>Offloading sFlow sampling rules.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For ConnectX-5 Adapters and ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>A locking mechanism to enable parallel insertion of rules into the software steering using the mlx5dv_dr API. The parallel insertion improves the insertion rate and takes place when adding Rx and Tx rules via the FDB domain.</li>\n\t\t<li>Option to match mlx5dv_dr API on Geneve tunnel using a dynamic flex parser. The option header consists of class, type, length and data. The parser should be configured using devx command, after which a rule can be created to match on parser ID and data.</li>\n\t\t<li>Geneve tunneling offload, including matching on extension header.</li>\n\t\t<li>Parallel insertion and deletion of offloaded rules using multiple&nbsp;OVS threads.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>[Beta] Modify GTP-U TEID. This support requires flex parser&nbsp;configuration.</li>\n\t\t<li>[Beta] Improved performance of OVS Connection Tracking flows by&nbsp;enabling the merge of the multi-table flow matches and actions into one joint flow.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Dx Adapters and above:</strong></p>\n\n<p>Added support for the following features:</p>\n\n<ul>\n\t<li>Transmitted packet timestamping accuracy can be improved when using a timestamp generated at the port level instead of a timestamp generated upon CQE creation. Tx port time-stamping better reflects the actual time of a packet&#39;s transmission. This feature is disabled by default. The feature can be enabled or disabled using the following command. ethtool --set-priv-flags tx_port_ts on / off.</li>\n\t<li>Offloading tunnel rules when the source interface is VF (in addition to uplink) in the Hypervisor.</li>\n\t<li>Using Mirroring Offload with Connection Tracking.</li>\n\t<li>ASO flow meter using the mlx5dv_dr API, which allows for monitoring the packet rate for specific flows. When a packet hits a flow that is connected to a flow meter, the rate of packets through this meter is evaluated, and the packet is marked with a color copied into one of the C registers, according to the current rate compared to the reference rate.</li>\n\t<li>ASO first hit using the mlx5dv_dr API, which allows for tracking rule hits by packets. When a packet hits a rule with the ASO first hit action, a flag is set indicating this event, and the original value of the flag is copied to one of the C registers.</li>\n\t<li>mlx5dv_dr API support for matching on a new field &quot;gtpu_first_ext_dw_0&quot;. This field enables packet filtering based on the GTP-U first extension header (first dword only). To enable parsing of tunnel GTP-U extension header, run the following command. ./cloud_fw_reset.py FLEX_PARSER_PROFILE_ENABLE=3.</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Lx Adapters and above:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>IPsec full offload support for extended sequence number, replay protection window and lifetime packet limit.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;All HCA&#39;s:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>New query GID API that allows for querying a single GID entry by its port and GID index, or querying for all GID tables of a specific device. This API works over ioctl instead of sysfs, which accelerates the querying process.</li>\n\t\t<li>Performing multi-host firmware reset in order to upgrade the device firmware. Firmware reset loads the new firmware in case it was burnt on the flash and was pending activation, and reload.</li>\n\t\t<li>[Alpha] Firmware live patching in the driver. Live patching updates the firmware without the need to perform firmware reset. However, it can only be applied in scenarios where the difference between the current and new firmware versions are minor, which is decided upon by the firmware itself.</li>\n\t\t<li>devlink tool for performing firmware reset in order to upgrade the device firmware. Firmware reset loads the new firmware in case it was burnt on the flash and was pending activation, and reloads the current firmware image from the flash in case no new firmware was pending. For further information, please refer to the the devlink man page.</li>\n\t\t<li>A resiliency mechanism for the driver to manually poll the command event queue (EQ) in case of a command timeout. In case the resiliency mechanism finds unhandled event queue entry (EQE) due to a lost interrupt, the driver will handle it, after which the command interface returns to a healthy state.</li>\n\t\t<li>Setting a sniffer private flag is deprecated and no longer required. In order to capture offloaded/RoCE traffic, tcpdump can now be run on the RDMA device.</li>\n\t\t<li>Added per-port reporters to devlink health to manage per-port health activities. Users can now access the devlink port reporters by specifying the port index in addition to the device devlink name through the devlink health commands API. This update was first introduced in iproute2 v5.8. As part of this feature, mlx5e Tx and Rx reporters are now redefined as devlink port reporters. For examples, please see devlink-health manpage</li>\n\t\t<li>Optimized memory consumption of memory registration in huge page systems. As an example, in a 2MB huge page system, 600 MB would be saved for 100 GB memory registration.</li>\n\t\t<li>mlx5dv API to modify the configured UDP source port for RoCE packets of a given RC/UC QP when QP is in RTS state.</li>\n\t\t<li>Accelerating Tx datapath by saving PCI bandwidth and CPU utilization. The savings are achieved by aggregating multiple packets into a single WQE. The feature is driven by xmit_more for certain traffic types, such as UDP.</li>\n\t</ul>\n\t</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 5.3:</strong></p>\n\n<ul>\n\t<li>Clearing min_rate on all SR-IOV legacy VFs after setting min_rate to at least one of the VFs did not disable QoS min_rate.</li>\n\t<li>An empty /usr/src/mlnx-ofa_kernel/default is now no longer created.</li>\n\t<li>An issue where installing packages through a repository failed after generation of metapackages using --add-kernel-support. The failure occurred due to excessive and incorrect Obsolete headers in those metapackages.Enabled installation of mlnx-ofa_kernel package to /bin/python3 instead of / usr/bin/python3 on RHEL 8.x systems.</li>\n\t<li>All IPoIB offload packets were wrongly counted as rx_csum_complete. These packets are now identified as rx_csum_unnecessary packets.</li>\n\t<li>mlx5dv_dr_rule_destroy segmentation fault could happen in rare cases with multiple rules on the same matcher with a different number of actions. This could happen after reusing an already deleted rule memory with less actions.</li>\n\t<li>An issue of moving to SwitchDev mode after configuring DSCP (Differentiated Service Code Point).</li>\n\t<li>Global traffic class configuration did not take effect on DC QPs (Dynamically Connected Queue Pairs).</li>\n\t<li>ib_send_bw traffic frequently dropped to zero when RDMA CM was used, because of incorrect&nbsp;min_rnr_timer setting on the responder side. The min_rnr_timer setting is now aligned with the setting in non-RDMA CM cases.</li>\n\t<li>Traffic did not pass over VFs with VST QinQ feature is enabled.</li>\n\t<li>When traffic was sent over Geneve VLAN with Tx VLAN offload enabled and TSO (TCP Segmentation Offload)&nbsp;or Tx csum enabled, traffic could be dropped and not sent to the wire.</li>\n\t<li>An issue that caused the firmware to restart upon installing mlnxofed-dpdk-upstream-libs package manually.</li>\n\t<li>Bad utility paths in rdma-core &quot;dracut&quot; hooks on SLES systems, which used to result in the following errors when running &quot;dracut&quot; with the &quot;--add rdma&quot; option. dracut-install:\n\t<ul>\n\t\t<li>ERROR: installing &lsquo;/usr/libexec/mlx4-setup.sh&rsquo; dracut: /usr/lib/dracut/dracut-install -D /var/tmp/dracut.UdCOSJ/ initramfs /usr/libexec/mlx4-setup.sh dracut-install: ERROR: installing &lsquo;/usr/libexec/rdma-set-sriov-vf&rsquo; dracut: /usr/lib/dracut/dracut-install -D /var/tmp/dracut.UdCOSJ/ initramfs /usr/libexec/rdma-set-sriov-vf</li>\n\t</ul>\n\t</li>\n\t<li>Traffic class value was not updated in DCT when set via sysfs.</li>\n\t<li>A doorbell loss issue on AMD platforms with Secure Memory Encryption (SME).</li>\n\t<li>Registering memory using mlx5dv_devx_umem_reg while forking. Without this fix, applications which use fork() or similar syscalls while using a memory registered with umem_reg could hang due to incorrect physical page mapping. This fix requires setting the IBV_FORK_SAFE environment variable.</li>\n\t<li>When&nbsp;unbinding the device resulted in the following message being printed to the dmesg: &quot;failed to disable DC tracer&quot;</li>\n\t<li>Content of file /sys/class/net//statistics/ multicast might have been out of date and might have displayed values lower than the real values.</li>\n\t<li>ERSPAN (Encapsulated Remote SPAN) protocol was available only when turning off Tx checksum offload.</li>\n\t<li>A udev script issue which caused non-mellanox devices to be renamed.</li>\n\t<li>Missing representor statistics when using ifconfig.</li>\n\t<li>Fixed wrong value of skb mark of received packets on representors.</li>\n\t<li>An issue which caused second port representors to be named as first port representors.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"kmod-mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"kmod-mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000GEFQV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGRTG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-304745465156","Version":"HPG8"},{"DeviceName":"MM2000GEFRA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGRTG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-324d-3030-304745465241","Version":"HPG8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MM1000GEFQV and MM2000GEFRA"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MM1000GEFQVおよびMM2000GEFRA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MM1000GEFQV and MM2000GEFRA Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG5<br />\n<br />\n<strong>Previous Version of Firmware:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>HPG5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features&nbsp;for:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3594040","datemodified":"2021-07-25T16:50:38","file_list":["cp048622.xml","cpqsetup.exe","payload.json","SAVGRTG8.rel","setup.dll"],"md5sum":"f7b018bcadaadf9a1bb1b42375c50c3b","name":"cp048622.exe","release":"2021-07-25T16:43:05","revision":"0","sha1sum":"3aea06c6bf6b4b7097f5dba02928c9a8aad1ef9b","size":"3MB","target_guids":["002340a5-4d00-314d-3030-304745465156","002340a5-4d00-324d-3030-304745465241"],"type_of_change":"1","version":"HPG8"}],"id":{"product":"54856ac460a544e2985eadac24abf907","version":"54dfbf8c90144a3490e2a1c7268c04f3"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MM1000GEFQV and MM2000GEFRA Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MM1000GEFQVおよびMM2000GEFRAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MM1000GEFQV","target_guid":"002340a5-4d00-314d-3030-304745465156","type":"sata"},{"id":"MM2000GEFRA","target_guid":"002340a5-4d00-324d-3030-304745465241","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T12:56:27","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MM1000GEFQV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MM2000GEFRA","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 546FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-full-rel-2_42_5044-779799-B21_Ax-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C8020","Version":"2.42.5044"},{"DeviceName":"HPE Ethernet 10Gb 2-port 546SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-full-rel-2_42_5044-779793-B21_0A-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C801F","Version":"2.42.5044"},{"DeviceName":"HPE Ethernet 100Gb 1-port 842QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_29_1016-874253-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900246","Version":"16.29.1016"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640 FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_29_1016-817749-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D3","Version":"14.29.1016"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_29_1016-817753-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D4","Version":"14.29.1016"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"tw","x_late":"此套件包含公用程式和二進位檔，可在 Linux 作業系統上升級僅 HPE Mellanox 乙太網路配接卡韌體。"},{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Mellanox Ethernet only adapter firmware on Linux Operating Systems."},{"lang":"ko","x_late":"이 패키지에는 Linux 운영 체제에서 HPE Mellanox 이더넷 전용 어댑터 펌웨어를 업그레이드할 수 있는 유틸리티와 바이너리가 포함되어 있습니다."},{"lang":"cn","x_late":"此软件包含有用于升级在Linux操作系统下运行的仅使用太网适配器的HPE Mellanox的固件所需的实用程序和二进制程序。"},{"lang":"ja","x_late":"このパッケージは、Linuxオペレーティングシステム上でHPE Mellanox Ethernetアダプター専用のファームウェアをアップグレードするためのユーティリティとバイナリを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 546SFP+ Adapter (779793-B21)</td>\n\t\t\t<td>2.42.5044</td>\n\t\t\t<td>HP_1200111023</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 546FLR-SFP+ Adapter (779799-B21)</td>\n\t\t\t<td>2.42.5044</td>\n\t\t\t<td>HP_2240110004</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)</td>\n\t\t\t<td>14.29.1016</td>\n\t\t\t<td>HP_2690110034</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</td>\n\t\t\t<td>14.29.1016</td>\n\t\t\t<td>HP_2420110034</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter&nbsp;(874253-B21)</td>\n\t\t\t<td>16.29.1016</td>\n\t\t\t<td>HPE0000000014</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"8328427","datemodified":"2021-01-19T08:12:11","file_list":["./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.14-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.14-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.14-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.14-1.1/CP045196.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.14-1.1/getmlnxinfo","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.14-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.14-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.14-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.14-1.1/nic_fw/fw-ConnectX3Pro-full-rel-2_42_5044-779793-B21_0A-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.14-1.1/nic_fw/fw-ConnectX3Pro-full-rel-2_42_5044-779799-B21_Ax-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.14-1.1/nic_fw/fw-ConnectX4Lx-rel-14_29_1016-817749-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.14-1.1/nic_fw/fw-ConnectX4Lx-rel-14_29_1016-817753-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.14-1.1/nic_fw/fw-ConnectX5-rel-16_29_1016-874253-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.14-1.1/nic_fw/mstflint","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.14-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.14-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045196.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045196.scexe"],"md5sum":"dc66d1ce846961752c9267d2c653965f","name":"firmware-nic-mellanox-ethernet-only-1.0.14-1.1.x86_64.rpm","release":"2021-01-19T08:07:08","revision":"0","sha1sum":"d223fddcf699dd58a21d2cf0a53b45e8ac5e00f6","size":"7MB","target_guids":["a6b1a447-382a-5a4f-15B3-1007103C8020","a6b1a447-382a-5a4f-15B3-1007103C801F","a6b1a447-382a-5a4f-15B3-101715900246","a6b1a447-382a-5a4f-15B3-1015159000D3","a6b1a447-382a-5a4f-15B3-1015159000D4"],"type_of_change":"1","version":"1.0.14"}],"id":{"product":"5c045315a07d45779f552f6cb831a2b4","version":"39d674eb07b34ff394185e6972ccecc8"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Updating firmware with rpm installed:</strong></p>\n\n<ul>\n\t<li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li>\n\t<li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li>\n\t<li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li>\n</ul>\n\n<p><strong>Updating firmware without installing rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li>\n\t<li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>rpmインストールによるファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>RPMを次のコマンドでインストールします: rpm -ivh <rpm_filename>.rpm これは、'/usr/lib/x86_64-linux-gnu'へコンテンツを解凍します。</li>\n\t<li>CPxxxxxx.scexeスクリプトは、'scexe-compat'フォルダーにあります。 </li>\n\t<li>ターミナルから、'/usr/lib/x86_64-linux-gnu/scexe-compat'の下の\"./CPxxxxxx.scexe\"を呼び出すか、'firmware-nic-*'の下の\"./setup\"を呼び出してファームウェアをアップデートします('firmware-nic-*'フォルダーの実際の名前はインストールしたrmpによって異なります)。</li>\n\t<li>アンインストールするには、次のコマンドを実行します: rpm -e <rpm_package_name></li>\n</ul>\n\n<p><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p>\n\n<ul>\n\t<li>rpmの内容を次のコマンドで抽出します: rpm2cpio <rpm_filename>.rpm | cpio -id</li>\n\t<li>これは、現在のディレクトリの'usr'フォルダーへrpmの内容を解凍します。</li>\n\t<li>ターミナルから'usr/lib/x86_64-linux-gnu/firmware-nic-*'に移動し、ファームウェアをアップデートするために./setupを実行します。'firmware-nic-*'フォルダーの実際の名前は、インストールしたrpmによって異なります。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"線上韌體升級公用程式 (Linux x86_64)，僅適用於 HPE Mellanox 乙太網路配接卡"},{"lang":"en","x_late":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Mellanox Ethernet only adapters"},{"lang":"ko","x_late":"HPE Mellanox 이더넷 전용 어댑터의 온라인 펌웨어 업그레이드 유틸리티(Linux x86_64)"},{"lang":"cn","x_late":"用于仅使用太网适配器的HPE Mellanox的在线固件升级实用程序（Linux x86_64）"},{"lang":"ja","x_late":"オンラインファームウェアアップグレードユーティリティ(Linux x86_64) for HPE Mellanox Ethernetアダプター専用"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-12T07:11:37","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5044 :</strong></p>\n\n<p>&nbsp; &nbsp;779799-B21 (HP Ethernet 10G 2-port 546FLR-SFP+ Adapter)<br />\n&nbsp; &nbsp;779793-B21 (HP Ethernet 10G 2-port 546SFP+ Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.27.4000:</strong></p>\n\n<p>&nbsp; &nbsp;817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.27.4000:</strong><br />\n&nbsp; &nbsp;817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following device is updated to 16.27.2008:</strong></p>\n\n<p>&nbsp; &nbsp;874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</p>\n\n<p><strong>New features and changes in version 16.27.2008:</strong></p>\n\n<ul>\n\t<li>Added the following segments, as appeared in the PRM, to the Resource Dump:\n\t<ul>\n\t\t<li>PRM_QUERY_QP</li>\n\t\t<li>PRM_QUERY_CQ</li>\n\t\t<li>PRM_QUERY_MKEY</li>\n\t\t<li>QUERY_VNIC_ENV</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>New features and changes in version 14.27.4000:</strong></p>\n\n<ul>\n\t<li>Added mlxconfig support for power reduction:\n\t<ul>\n\t\t<li>PCI CAP</li>\n\t\t<li>AUTO_POWER_SAVE_LINK_DOWN</li>\n\t</ul>\n\t</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Fixes submitted in version 2.42.5044 :</strong></p>\n\n<ul>\n\t<li>An issue that prevented the firmware from detecting a link_down event thus preventing the IB bond interface from going to a failover mode.</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 14.27.4000:</strong></p>\n\n<ul>\n\t<li>The sent packet hung while the device entered FLR mode.</li>\n\t<li>Enabled Bar configuration bytewise by applying the write_en bitmask.</li>\n\t<li>The device hung while running the sw reset flow under heavy stress and with many open resources.</li>\n\t<li>The completions (CQ)completed due to a race condition in the firmware transport error handlers, and the error stressors, where the error stressors would hang the firmware transport error handler flow.&nbsp;</li>\n\t<li>The fragmented IP packets were dropped.</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 16.27.2008:</strong></p>\n\n<ul>\n\t<li>Although the effective BER (after FEC) was expected to meet the design targets (e.g. 10e-14 or lower), occasionally it was higher.</li>\n\t<li>High BER occured when connecting cables of type 0.5/1m DAC to an HDR speed.</li>\n\t<li>The PCIe Tx parameters did not load correctly when the speed was changed after the PCIe link was disabled.</li>\n\t<li>The desched_threshold field did not work properly.</li>\n\t<li>The &quot;roce_adp_retrans&quot; counter was presenting the values of the &quot;local_ack_timeout_err&quot; counter.</li>\n\t<li>If Relaxed Ordering was disabled by running the &quot;setpci&quot; command, it would not be functional even after re-enabling it by running the &quot;setpci&quot; command again.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5044 :</strong></p>\n\n<p>&nbsp; &nbsp;779799-B21 (HPE Ethernet 10G 2-port 546FLR-SFP+ Adapter)<br />\n&nbsp; &nbsp;779793-B21 (HPE Ethernet 10G 2-port 546SFP+ Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.29.1016:</strong></p>\n\n<p>&nbsp; &nbsp;817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.29.1016:</strong><br />\n&nbsp; &nbsp;817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following device is updated to 16.29.1016:</strong></p>\n\n<p>&nbsp; &nbsp;874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</p>\n\n<p><strong>New features and changes in version 16.28.1016:</strong></p>\n\n<ul>\n\t<li>Added the following segments, as appeared in the PRM, to the Resource Dump:\n\t<ul>\n\t\t<li>PRM_QUERY_QP</li>\n\t\t<li>PRM_QUERY_CQ</li>\n\t\t<li>PRM_QUERY_MKEY</li>\n\t\t<li>QUERY_VNIC_ENV</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>New features and changes in version 14.29.1016:</strong></p>\n\n<ul>\n\t<li>Added mlxconfig support for power reduction:\n\t<ul>\n\t\t<li>PCI CAP</li>\n\t\t<li>AUTO_POWER_SAVE_LINK_DOWN</li>\n\t</ul>\n\t</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Fixes submitted in version 2.42.5044 :</strong></p>\n\n<ul>\n\t<li>An issue that prevented the firmware from detecting a link_down event thus preventing the IB bond interface from going to a failover mode.</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 14.29.1016:</strong></p>\n\n<ul>\n\t<li>The sent packet hung while the device entered FLR mode.</li>\n\t<li>Enabled Bar configuration bytewise by applying the write_en bitmask.</li>\n\t<li>The device hung while running the sw reset flow under heavy stress and with many open resources.</li>\n\t<li>The completions (CQ)completed due to a race condition in the firmware transport error handlers, and the error stressors, where the error stressors would hang the firmware transport error handler flow.&nbsp;</li>\n\t<li>The fragmented IP packets were dropped.</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 16.29.1016:</strong></p>\n\n<ul>\n\t<li>Although the effective BER (after FEC) was expected to meet the design targets (e.g. 10e-14 or lower), occasionally it was higher.</li>\n\t<li>High BER occured when connecting cables of type 0.5/1m DAC to an HDR speed.</li>\n\t<li>The PCIe Tx parameters did not load correctly when the speed was changed after the PCIe link was disabled.</li>\n\t<li>The desched_threshold field did not work properly.</li>\n\t<li>The &quot;roce_adp_retrans&quot; counter was presenting the values of the &quot;local_ack_timeout_err&quot; counter.</li>\n\t<li>If Relaxed Ordering was disabled by running the &quot;setpci&quot; command, it would not be functional even after re-enabling it by running the &quot;setpci&quot; command again.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"","value":"HPE ProLiant SL4500 Chassis"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 System"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_NIC","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWKGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAnAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-3047574b4756","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB004000GWKGV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB004000GWKGV Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"6111137","datemodified":"2021-07-23T07:59:40","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-5.1/CP048098.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-5.1/HVLAnAaseFG1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048098.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048098.scexe"],"md5sum":"c5cce600f3c6abda7e81c7f1edbad967","name":"firmware-hdd-ca21e169e2-HPG1-5.1.x86_64.rpm","release":"2021-07-23T07:47:13","revision":"0","sha1sum":"7fd2a6646c7906ee9d8784a89983bec4b1adb1fd","size":"5MB","target_guids":["4d2340a5-3042-3430-3030-3047574b4756"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"02a1f5d0f0e244c0b4c2ace636d0f60b","version":"140b27b6a05946a38b8401ec9fcfdc64"},"installation":{"command":"CP041494.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB004000GWKGV Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) -  MB004000GWKGV ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB004000GWKGV","target_guid":"4d2340a5-3042-3430-3030-3047574b4756","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T12:48:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB004000GWKGV","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the SRIOV virtual function drivers for the HPE Blade Intel ixgbe Ethernet NICs running under Red Hat Enterprise Linux 7."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7で動作するHPE Blade Intel ixgbe Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"62900","datemodified":"2021-03-08T18:23:57","file_list":["./etc/depmod.d/hp-ixgbevf.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/hp-ixgbevf","./lib/modules/3.10.0-1160.el7.x86_64/extra/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/kmod-hp-ixgbevf_bl/component.xml"],"md5sum":"f70dba16d37671f891799ab920187bd2","name":"kmod-hp-ixgbevf_bl-4.9.3-1.rhel7u9.x86_64.rpm","release":"2021-03-08T18:13:04","revision":"0","sha1sum":"80f15d86f74ba0e3bb6ef72741c6d6f67be55769","size":"61KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec674b05ac"],"type_of_change":"0","version":"4.9.3-1"},{"bytes":"62899","datemodified":"2021-03-08T18:19:39","file_list":["./etc/depmod.d/hp-ixgbevf.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/hp-ixgbevf","./lib/modules/3.10.0-1127.el7.x86_64/extra/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/kmod-hp-ixgbevf_bl/component.xml"],"md5sum":"3d079135a638cbf5dc430db567f12a96","name":"kmod-hp-ixgbevf_bl-4.9.3-1.rhel7u8.x86_64.rpm","release":"2021-03-08T18:13:04","revision":"0","sha1sum":"f7ce9704b8e9ac5f9334a529626e07f2e731678d","size":"61KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec674b05ac"],"type_of_change":"0","version":"4.9.3-1"}],"id":{"product":"5230830842514ef8a52b0b19a00fb203","version":"1fe9919da8234720accc28522b08cd41"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Intel ixgbevf Drivers for Red Hat Enterprise Linux 7"},{"lang":"ja","x_late":"HPE Blade Intel ixgbevfドライバー for Red Hat Enterprise Linux 7"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c18d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>These drivers have been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 7, Updates 8 and 9.</p>\n","curr_fixes_x_late":"<p>This product corrects an issue seen when enabling SRIOV, where the VFs have the same, duplicated MAC address.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"kmod-hp-ixgbevf_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbevf_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbevf_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbevf_bl","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GZCNE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K511HPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-30475a434e45","Version":"HPG1"},{"DeviceName":"VK000960GZCNF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K511HPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-30475a434e46","Version":"HPG1"},{"DeviceName":"VK001920GZCNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K511HPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-30475a434e48","Version":"HPG1"},{"DeviceName":"VK003840GZCNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K511HPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-30475a434e4b","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000480GZCNE、VK000960GZCNF、VK001920GZCNHおよびVK003840GZCNK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"26057794","datemodified":"2021-08-30T04:59:21","file_list":["/CP049156_BUILD_3.data","/CP049156.vmexe","/CP049156.vmexe64","/CP049156.vmfile","/CP049156_VMw.zip","/CP049156.xml","/payload.json","/CP049156_VMw.zip/index.xml","/CP049156_VMw.zip/vendor-index.xml","/CP049156_VMw.zip/metadata.zip","/CP049156_VMw.zip/vib20/CP049156/HPE_bootbank_CP049156_HPG1.3-7.0.0.15843807.vib","/CP049156_VMw.zip/metadata.zip/vendor-index.xml","/CP049156_VMw.zip/metadata.zip/vmware.xml","/CP049156_VMw.zip/metadata.zip/vibs/CP049156--8316550600226118748.xml","/CP049156_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049156_HPG1.3-7.0.0.15843807.xml"],"md5sum":"961396c554f1b93cfeea6d2a9a79787f","name":"CP049156.zip","release":"2021-08-30T04:54:21","revision":"0","sha1sum":"15a4acb70dd80532415976cf73c9e7d42e93776f","size":"24MB","target_guids":["562340a5-304b-3030-3438-30475a434e45","562340a5-304b-3030-3936-30475a434e46","562340a5-304b-3130-3932-30475a434e48","562340a5-304b-3330-3834-30475a434e4b"],"type_of_change":"1","version":"HPG1","vib_list":[{"name":"CP049156","version":"HPG1.3-7.0.0.15843807"}]}],"id":{"product":"8e9f61780275418686c8b0a671e012c9","version":"d9433ef91e984ffa990a67b442c25290"},"installation":{"command":"CP043256.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>HP Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - VK000480GZCNE、VK000960GZCNF、VK001920GZCNHおよびVK003840GZCNKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VK000480GZCNE","target_guid":"562340a5-304b-3030-3438-30475a434e45","type":"sata"},{"id":"VK000960GZCNF","target_guid":"562340a5-304b-3030-3936-30475a434e46","type":"sata"},{"id":"VK001920GZCNH","target_guid":"562340a5-304b-3130-3932-30475a434e48","type":"sata"},{"id":"VK003840GZCNK","target_guid":"562340a5-304b-3330-3834-30475a434e4b","type":"sata"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-27T14:55:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>The FW version is Changed from HPG0 to HPG1. Changed the thermal throttling scheme. SMART 60℃ was matched with Tcase 70℃ and Run the thermal throttling at SMART 65℃.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK000960GZCNF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GZCNE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GZCNK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GZCNH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"QLogic driver for VMware vSphere 6.7"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"812796","datemodified":"2021-08-27T03:26:52","file_list":["/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip","/cp048722.xml","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/doc/README.txt","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/doc/release_note_qlnativefc_3.1.46.0-1OEM.670.0.0.8169922.qlnativefc","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/index.xml","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/vendor-index.xml","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/metadata.zip","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/vib20/qlnativefc/Marvell_bootbank_qlnativefc_3.1.46.0-1OEM.670.0.0.8169922.vib","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/metadata.zip/vendor-index.xml","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/metadata.zip/vmware.xml","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/metadata.zip/vibs/qlnativefc-3264416984770026613.xml","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/metadata.zip/bulletins/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922.xml"],"md5sum":"ab125a4cbaea598fa1321c6144ac50fc","name":"cp048722.zip","release":"2021-08-27T03:26:07","revision":"0","sha1sum":"b3210c5f4beb5af57e3300f614db13aab930fd52","size":"793KB","target_guids":[],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"qlnativefc","version":"3.1.46.0-1OEM.670.0.0.8169922"}]}],"id":{"product":"50547c3db7f94242924e4ecb19f81264","version":"574b93dd8f514b5997d2074e8cab62b0"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware&nbsp;vSphere Update Manager&nbsp;or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VMware&nbsp;vSphere Update Manager and the esxcli commands</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic Fibre Channel driver component for VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015D","subven":"1077","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015C","subven":"1077","target_guid":"","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-18T06:47:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Made improvements to the Fabric Port Identification Number (FPIN) and Universal Storage Area Network (SAN) Congestion Mitigation(USCM) Congestion Management algorithm</li>\n\t<li>\n\t<p>Implemented the vmkmgmt Application programming Interface (API) to report Non-Volatile Memory Express (NVMe) target info and send Non-Volatile Memory Express (NVMe) pass through commands</p>\n\t</li>\n</ul>\n\n<p>Driver version 3.1.46.0</p>\n","curr_fixes_x_late":"<ul>\n\t<li>Fixed an unwanted behavior where Get Port Speed Capabilities (GPSC) failures were leading to intelligent interleaved direct memory access (IIDMA) for target being set to 1GB/s. This is described in <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00115969en_us\">Advisory: HPE Host Bus Adapters - HPE Platforms Running VMware ESXi 6.5 / 6/7 / 7.0 and Configured With Certain HPE Host Bus Adapters May Experience Severe Performance Degradation When Connected to Brocade FOS v8.0.1 (or Prior)</a></li>\n\t<li>Addressed unwanted behavior with Fabric Port Identification Number (FPIN) based congestion throttling leading to poor performance.</li>\n\t<li>Fixed an unwanted behavior where stale connection IDs could be used with Fibre Channel- Non Volatile Memory Express (FC-NVMe) traffic.</li>\n\t<li>\n\t<p>Fixed an unwanted behavior with response queue handling to avoid the problem referenced by <a href=\"https://kb.vmware.com/s/article/81721\">https://kb.vmware.com/s/article/81721</a></p>\n\t</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"qlnativefc:3.1.46.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH0600JDYTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFL4CD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3630-304a4459544e","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: EH0600JDYTN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - EH0600JDYTN Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong></p>\n\n<ul>\n\t<li>Fixes a data integrity risk where stale data is mistakenly used from cache.</li>\n\t<li>Fixes a data integrity risk where stale data is returned on an unaligned overlapped write-read operation.</li>\n\t<li>Fixes a data integrity risk during a sequential read and write workload when a recovered error is encountered, which could cause incomplete data to be read.&nbsp;</li>\n</ul>\n\n<p><br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p><strong>&nbsp; &nbsp; &nbsp; </strong>None.</p>\n"}],"files":[{"bytes":"3675016","datemodified":"2021-07-24T05:22:11","file_list":["cp048553.xml","cpqsetup.exe","HKFL4CD7.rel","payload.json","setup.dll"],"md5sum":"fcc0ef66fb07d449d47f5a327fe9b726","name":"cp048553.exe","release":"2021-07-24T05:14:04","revision":"0","sha1sum":"56c312cac2efc6e29b510e373441f2968f465362","size":"3MB","target_guids":["002340a5-4500-3048-3630-304a4459544e"],"type_of_change":"2","version":"HPD7"}],"id":{"product":"68a7de4833704c8fb3dbc75f2b162b30","version":"ddf8a1a086fc4d94876cddb46525ca00"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EH0600JDYTN Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EH0600JDYTNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EH0600JDYTN","target_guid":"002340a5-4500-3048-3630-304a4459544e","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T04:14:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":"<ul>\n\t<li>Fixes a data integrity risk where stale data is mistakenly used from cache.</li>\n\t<li>Fixes a data integrity risk where stale data is returned on an unaligned overlapped write-read operation.</li>\n\t<li>Fixes a data integrity risk during a sequential read and write workload when a recovered error is encountered, which could cause incomplete data to be read.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Fixes a data integrity risk where stale data is mistakenly used from cache.</li>\n\t<li>Fixes a data integrity risk where stale data is returned on an unaligned overlapped write-read operation.</li>\n\t<li>Fixes a data integrity risk during a sequential read and write workload when a recovered error is encountered, which could cause incomplete data to be read.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH0600JDYTN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6961048","datemodified":"2021-05-17T19:49:31","file_list":["/CP047888.vmexe","/CP047888.vmfile","/CP047888.xml","/README.txt"],"md5sum":"e938b2c22dca7bbc9d0aaf662d611e6f","name":"CP047888.zip","release":"2021-05-18T00:46:06","revision":"0","sha1sum":"9a903e6cd3dc44563548539eb53a139dcc86385e","size":"6MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021","vib_list":[]}],"id":{"product":"40ac168079914e77b07d902faf8d27db","version":"940d4bbc0300491782e81debae24f85c"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component requires that the CRU driver be loaded before the component can run.<br />\nThe minimum CRU version for 5.1 is 5.0.3.9.<br />\nThe minimum CRU version for 5.5 is 5.5.4.1.<br />\nThe minimum CRU version for 6.0 is 6.0.8.<br />\nThe minimum CRU version for 6.5 is 6.5.8.<br />\nThe minimum CRU version for 6.7 is 6.7.10.<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>SPP Offline mode boots a special Linux OS environment, thus the Linux Components are used, not the VMware Components</li>\n</ul>\n\n<p><br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Download the appropriate SPP</li>\n\t<li>Add the component to the SPP</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run SUM</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps to complete the firmware update</li>\n\t<li>Refer to the SPP documentation for detailed instructions at:&nbsp; <a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Component ( CPxxxxxx.zip) in a temporary directory</li>\n\t<li>From the same directory, unzip the Component:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>To perform the standalone installation, execute the command:<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>Follow the directions given by the Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system for the firmware update to take effect</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、実行する前にCRUドライバーがロードされている必要があります。<br />\n5.1の最小CRUバージョンは5.0.3.9です。<br />\n5.5の最小CRUバージョンは5.5.4.1です。<br />\n6.0の最小CRUバージョンは6.0.8です。<br />\n6.5の最小CRUバージョンは6.5.8です。<br />\n6.7の最小CRUバージョンは6.7.10です。<br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMwareコンポーネントではなく、Linuxコンポーネントが用いられます</li>\n</ul>\n\n<p><br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします</li>\n\t<li>SPPにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします</li>\n\t<li>SUMを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います</li>\n\t<li>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>コンポーネント (CPxxxxxx.zip)を一時ディレクトリに置きます</li>\n\t<li>同じディレクトリからコンポーネントをunzipします:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>スタンドアロンのインストールを行うために、次のコマンドを実行します：<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>コンポーネントの指示に従います</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n\t<li>システムを再起動し、ファームウェアのアップデートを有効にします</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware ESXi- HPE ProLiant XL230a/XL250a Gen9 (U13) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for VMware ESXi - HPE ProLiant XL230a/XL250a Gen9（U13）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"5","minor":"1","name":"VMware vSphere 5.1","platform":"vmware_esx_server","sr":"OEM"},{"major":"5","minor":"5","name":"VMware vSphere 5.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-06T15:33:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","latest_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358.  These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390.  These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"}],"sw_keys":[{"name":"U13","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900374","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware and boot BIOS of Emulex Fibre Channel host bus adapters."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"8349996","datemodified":"2021-08-25T13:20:10","file_list":["/CP048595_BUILD_7.data","/CP048595.vmexe","/CP048595.vmexe64","/CP048595.vmfile","/CP048595_VMw.zip","/CP048595.xml","/payload.json","/CP048595_VMw.zip/index.xml","/CP048595_VMw.zip/vendor-index.xml","/CP048595_VMw.zip/metadata.zip","/CP048595_VMw.zip/vib20/CP048595/HPE_bootbank_CP048595_2021.10.01.7-6.5.0.4240417.vib","/CP048595_VMw.zip/metadata.zip/vendor-index.xml","/CP048595_VMw.zip/metadata.zip/vmware.xml","/CP048595_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048595_2021.10.01.7-6.5.0.4240417.xml","/CP048595_VMw.zip/metadata.zip/vibs/CP048595-4175442038140766682.xml"],"md5sum":"214bc3b3fcab3b69d4fd1a4c6a69a8a9","name":"CP048595.zip","release":"2021-08-25T13:13:06","revision":"0","sha1sum":"4ad448cd7b617e5386fb99a07d0d0e0db0aaf804","size":"7MB","target_guids":[],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"CP048595","version":"2021.10.01.7-6.5.0.4240417"}]}],"id":{"product":"9da5afbf94f64b148ef777c0b0b4726f","version":"f4fc2a4064094106baae966ec39c1735"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated if the ESXi host is Gen9 Server or Enter the IP or DNS address of the iLO of the ESXi host if the Sever is Gen10 and above</li>\n\t<li>Enter the ESXi host/iLO credentials (root or administrator username and password) based on Gen9/Gen10 and above</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Fibre Channel Host Bus Adapters for VMware vSphere  6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"20000"},"supported_devices":[{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T10:35:38","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\" dir=\"LTR\" style=\"width:935px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Adapter</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Speed</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Universal Boot Image</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Firmware</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>UEFI</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Boot Bios</strong></p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE 81E 8Gb Single Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.80a3</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">2.10X6</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.183.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.9.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE 82E 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.80a3</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">2.10X6</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.183.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.9.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE 84E 8Gb Quad Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.80a3</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">2.10X6</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.183.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.9.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1000E 16Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1000E 16Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100E 16Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100E 16Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100E Quad Port 16Gb Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"emulex","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000JEXYA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRESD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a45585941","Version":"HPD9"},{"DeviceName":"MB6000JEXYB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRESD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a45585942","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SAS drive models: MB4000JEXYA and MB6000JEXYB Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSASドライブモデルのファームウェアを提供します。 MB4000JEXYAおよびMB6000JEXYBドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB4000JEXYA and MB6000JEXYB Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD8</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p>&nbsp;<strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4891060","datemodified":"2021-07-23T07:33:20","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-0f923833e9-HPD9-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-0f923833e9-HPD9-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-0f923833e9-HPD9-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-0f923833e9-HPD9-6.1/CP048165.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-0f923833e9-HPD9-6.1/TTMRESD9.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-0f923833e9-HPD9-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-0f923833e9-HPD9-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-0f923833e9-HPD9-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-0f923833e9-HPD9-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048165.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048165.scexe"],"md5sum":"b678cb94a2e3581a163335c3122a2076","name":"firmware-hdd-0f923833e9-HPD9-6.1.x86_64.rpm","release":"2021-07-23T07:20:07","revision":"0","sha1sum":"608603bc1f12e591a5ddc9af55e84aa49ae164fd","size":"4MB","target_guids":["002340a5-4d00-3442-3030-304a45585941","002340a5-4d00-3642-3030-304a45585942"],"type_of_change":"1","version":"HPD9"}],"id":{"product":"15b4903e0d104da184afbca47ab6234b","version":"60fe2e23f7c343f484ce686336089385"},"installation":{"command":"CP040306.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB4000JEXYA and MB6000JEXYB Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB4000JEXYAおよびMB6000JEXYBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"MB4000JEXYA","target_guid":"002340a5-4d00-3442-3030-304a45585941","type":"sas"},{"id":"MB6000JEXYB","target_guid":"002340a5-4d00-3642-3030-304a45585942","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T19:29:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000JEXYB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB4000JEXYA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GXAWE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304758415745","Version":"HPG1"},{"DeviceName":"VK000480GXAWK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-30475841574b","Version":"HPG1"},{"DeviceName":"VK000960GXAWL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-30475841574c","Version":"HPG1"},{"DeviceName":"VK001920GXAWN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-30475841574e","Version":"HPG1"},{"DeviceName":"VK003840GXAWP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304758415750","Version":"HPG1"},{"DeviceName":"VK007680GXAWQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-304758415751","Version":"HPG1"},{"DeviceName":"MK000480GXAWF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304758415746","Version":"HPG1"},{"DeviceName":"MK000960GXAXB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304758415842","Version":"HPG1"},{"DeviceName":"MK001920GXAWR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304758415752","Version":"HPG1"},{"DeviceName":"MK003840GXAWT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-304758415754","Version":"HPG1"},{"DeviceName":"VR000240GXBBL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3234-30475842424c","Version":"HPG1"},{"DeviceName":"MR000480GXBGH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3438-304758424748","Version":"HPG1"},{"DeviceName":"MR000960GXBGK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3936-30475842474b","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000240GXAWE, VK000480GXAWK, VK000960GXAWL, VK001920GXAWN, VK003840GXAWP, VK007680GXAWQ, MK000480GXAWF, MK000960GXAXB, MK001920GXAWR, MK003840GXAWT, VR000240GXBBL, MR000480GXBGH and MR000960GXBGK"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000240GXAWE、VK000480GXAWK、VK000960GXAWL、VK001920GXAWN、VK003840GXAWP、VK007680GXAWQ、MK000480GXAWF、MK000960GXAXB、MK001920GXAWR、MK003840GXAWT、VR000240GXBBL、MR000480GXBGH、およびMR000960GXBGK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- VK000240GXAWE, VK000480GXAWK, VK000960GXAWL, VK001920GXAWN, VK003840GXAWP, VK007680GXAWQ, MK000480GXAWF, MK000960GXAXB, MK001920GXAWR, MK003840GXAWT, VR000240GXBBL, MR000480GXBGH and MR000960GXBGK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"6650079","datemodified":"2021-07-27T15:58:17","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8f9bf23306-HPG1-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f9bf23306-HPG1-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f9bf23306-HPG1-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f9bf23306-HPG1-2.1/CP049158.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f9bf23306-HPG1-2.1/M5300AG1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f9bf23306-HPG1-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f9bf23306-HPG1-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f9bf23306-HPG1-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f9bf23306-HPG1-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049158.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049158.scexe"],"md5sum":"8fb9e1a512a5dcee7071689e9f8260df","name":"firmware-hdd-8f9bf23306-HPG1-2.1.x86_64.rpm","release":"2021-07-27T15:45:05","revision":"0","sha1sum":"4d1c48543a30aca6b84516048ffd1226d93de7ea","size":"6MB","target_guids":["562340a5-304b-3030-3234-304758415745","562340a5-304b-3030-3438-30475841574b","562340a5-304b-3030-3936-30475841574c","562340a5-304b-3130-3932-30475841574e","562340a5-304b-3330-3834-304758415750","562340a5-304b-3730-3638-304758415751","4d2340a5-304b-3030-3438-304758415746","4d2340a5-304b-3030-3936-304758415842","4d2340a5-304b-3130-3932-304758415752","4d2340a5-304b-3330-3834-304758415754","562340a5-3052-3030-3234-30475842424c","4d2340a5-3052-3030-3438-304758424748","4d2340a5-3052-3030-3936-30475842474b"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"49ef8a3b84714e97bc36564b7cd48c52","version":"35a6f51c6350416992e56924dcc78818"},"installation":{"command":"CP043255.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/jp/servers/spp_dl　\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK000240GXAWE, VK000480GXAWK, VK000960GXAWL, VK001920GXAWN, VK003840GXAWP, VK007680GXAWQ, MK000480GXAWF, MK000960GXAXB, MK001920GXAWR, MK003840GXAWT, VR000240GXBBL, MR000480GXBGH and MR000960GXBGK Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VK000240GXAWE、VK000480GXAWK、VK000960GXAWL、VK001920GXAWN、VK003840GXAWP、VK007680GXAWQ、MK000480GXAWF、MK000960GXAXB、MK001920GXAWR、MK003840GXAWT、VR000240GXBBL、MR000480GXBGH、およびMR000960GXBGKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VK000240GXAWE","target_guid":"562340a5-304b-3030-3234-304758415745","type":"sata"},{"id":"VK000480GXAWK","target_guid":"562340a5-304b-3030-3438-30475841574b","type":"sata"},{"id":"VK000960GXAWL","target_guid":"562340a5-304b-3030-3936-30475841574c","type":"sata"},{"id":"VK003840GXAWP","target_guid":"562340a5-304b-3330-3834-304758415750","type":"sata"},{"id":"VK007680GXAWQ","target_guid":"562340a5-304b-3730-3638-304758415751","type":"sata"},{"id":"MK000480GXAWF","target_guid":"4d2340a5-304b-3030-3438-304758415746","type":"sata"},{"id":"MK000960GXAXB","target_guid":"4d2340a5-304b-3030-3936-304758415842","type":"sata"},{"id":"MK001920GXAWR","target_guid":"4d2340a5-304b-3130-3932-304758415752","type":"sata"},{"id":"MK003840GXAWT","target_guid":"4d2340a5-304b-3330-3834-304758415754","type":"sata"},{"id":"VR000240GXBBL","target_guid":"562340a5-3052-3030-3234-30475842424c","type":"sata"},{"id":"MR000480GXBGH","target_guid":"4d2340a5-3052-3030-3438-304758424748","type":"sata"},{"id":"MR000960GXBGK","target_guid":"4d2340a5-3052-3030-3936-30475842474b","type":"sata"},{"id":"VK001920GXAWN","target_guid":"562340a5-304b-3130-3932-30475841574e","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-27T15:39:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>The updates were included in a regularly scheduled 5300 maintenance release. This firmware has a security version upgrade to include TCGe SKUs and prevent a downloading of a back level firmware version of HPG0 after upgrading to HPG1.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK001920GXAWR","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK003840GXAWT","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VR000240GXBBL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GXAWP","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MR000960GXBGK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GXAWK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GXAXB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GXAWE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GXAWL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GXAWN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK007680GXAWQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GXAWF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MR000480GXBGH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000JFJTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGNSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-304a464a5448","Version":"HPD4"},{"DeviceName":"MM002000JWCNF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGNSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304d-3230-3030-304a57434e46","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MM1000JFJTH and MM002000JWCNF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MM1000JFJTH and MM002000JWCNF Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"17286572","datemodified":"2021-08-27T07:07:56","file_list":["/CP048392_BUILD_2.data","/CP048392.vmexe","/CP048392.vmexe64","/CP048392.vmfile","/CP048392_VMw.zip","/CP048392.xml","/payload.json","/CP048392_VMw.zip/index.xml","/CP048392_VMw.zip/vendor-index.xml","/CP048392_VMw.zip/metadata.zip","/CP048392_VMw.zip/vib20/CP048392/HPE_bootbank_CP048392_HPD4.2-7.0.0.15843807.vib","/CP048392_VMw.zip/metadata.zip/vendor-index.xml","/CP048392_VMw.zip/metadata.zip/vmware.xml","/CP048392_VMw.zip/metadata.zip/vibs/CP048392--1101656020403834514.xml","/CP048392_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048392_HPD4.2-7.0.0.15843807.xml"],"md5sum":"6fee6ffa216cf974b8e35dc6f770a3e6","name":"CP048392.zip","release":"2021-08-27T07:02:18","revision":"0","sha1sum":"0489af9f7ccc59e2cc574ee081211463bdcf7cae","size":"16MB","target_guids":["002340a5-4d00-314d-3030-304a464a5448","4d2340a5-304d-3230-3030-304a57434e46"],"type_of_change":"1","version":"HPD4","vib_list":[{"name":"CP048392","version":"HPD4.2-7.0.0.15843807"}]}],"id":{"product":"4aaa1b96312a4790820f2c40ac3eb0e7","version":"d35a2ba0f8c94671a10b0aa6f40500cf"},"installation":{"command":"CP040517.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - MM1000JFJTH and MM002000JWCNF Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MM1000JFJTH","target_guid":"002340a5-4d00-314d-3030-304a464a5448","type":"sas"},{"id":"MM002000JWCNF","target_guid":"4d2340a5-304d-3230-3030-304a57434e46","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T12:02:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MM002000JWCNF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MM1000JFJTH","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO0400KEFHN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3430-304b4546484e","Version":"HPK4"},{"DeviceName":"MO0800KEFHP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3830-304b45464850","Version":"HPK4"},{"DeviceName":"MO1600KEFHQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304b45464851","Version":"HPK4"},{"DeviceName":"MO2000KEFHR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-324f-3030-304b45464852","Version":"HPK4"},{"DeviceName":"MT0800KEXUU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3054-3830-304b45585555","Version":"HPK4"},{"DeviceName":"MT1600KEXUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3154-3630-304b45585556","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MO0400KEFHN, MO0800KEFHP, MO1600KEFHQ, MO2000KEFHR, MT0800KEXUU and MT1600KEXUV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for VMware ESXi - &nbsp;MO0400KEFHN, MO0800KEFHP, MO1600KEFHQ, MO2000KEFHR, MT0800KEXUU&nbsp;and MT1600KEXUV Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16035363","datemodified":"2021-08-31T03:53:30","file_list":["/CP048489_BUILD_2.data","/CP048489.vmexe","/CP048489.vmexe64","/CP048489.vmfile","/CP048489_VMw.zip","/CP048489.xml","/payload.json","/CP048489_VMw.zip/index.xml","/CP048489_VMw.zip/vendor-index.xml","/CP048489_VMw.zip/metadata.zip","/CP048489_VMw.zip/vib20/CP048489/HPE_bootbank_CP048489_HPK4.2-7.0.0.15843807.vib","/CP048489_VMw.zip/metadata.zip/vendor-index.xml","/CP048489_VMw.zip/metadata.zip/vmware.xml","/CP048489_VMw.zip/metadata.zip/vibs/CP048489--2754645189579232014.xml","/CP048489_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048489_HPK4.2-7.0.0.15843807.xml"],"md5sum":"aaffa0714c4954094182dc1acae8c64e","name":"CP048489.zip","release":"2021-08-31T03:48:21","revision":"0","sha1sum":"5192088178cfda4605dd9f6127b528f6f993df5d","size":"15MB","target_guids":["002340a5-4d00-304f-3430-304b4546484e","002340a5-4d00-304f-3830-304b45464850","002340a5-4d00-314f-3630-304b45464851","002340a5-4d00-324f-3030-304b45464852","002340a5-4d00-3054-3830-304b45585555","002340a5-4d00-3154-3630-304b45585556"],"type_of_change":"1","version":"HPK4","vib_list":[{"name":"CP048489","version":"HPK4.2-7.0.0.15843807"}]}],"id":{"product":"199eba867d0c4e0892143a3378628d99","version":"b67745fe5bd84e1589d3811e6b312365"},"installation":{"command":"CP040195.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d /CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d /CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d /CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d /CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi  - MO0400KEFHN, MO0800KEFHP, MO1600KEFHQ, MO2000KEFHR, MT0800KEXUU and MT1600KEXUV Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MT0800KEXUU","target_guid":"002340a5-4d00-3054-3830-304b45585555","type":"nvme"},{"id":"MT1600KEXUV","target_guid":"002340a5-4d00-3154-3630-304b45585556","type":"nvme"},{"id":"MO0400KEFHN","target_guid":"002340a5-4d00-304f-3430-304b4546484e","type":"nvme"},{"id":"MO0800KEFHP","target_guid":"002340a5-4d00-304f-3830-304b45464850","type":"nvme"},{"id":"MO1600KEFHQ","target_guid":"002340a5-4d00-314f-3630-304b45464851","type":"nvme"},{"id":"MO2000KEFHR","target_guid":"002340a5-4d00-324f-3030-304b45464852","type":"nvme"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-14T12:04:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MT0800KEXUU","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT1600KEXUV","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO0400KEFHN","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO2000KEFHR","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO1600KEFHQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO0800KEFHP","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"VMware ESXi 7.0 Mellanox mst driver for Mellanox devices"},{"lang":"ja","x_late":"VMware ESXi 7.0 Mellanox mstドライバー for Mellanoxデバイス"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"31548","datemodified":"2021-08-27T13:11:56","file_list":["/Mellanox-NATIVE-NMST_4.14.3.3-1OEM.700.1.0.15525992_16211416.zip","/cp048360.xml","/Mellanox-NATIVE-NMST_4.14.3.3-1OEM.700.1.0.15525992_16211416.zip/index.xml","/Mellanox-NATIVE-NMST_4.14.3.3-1OEM.700.1.0.15525992_16211416.zip/vendor-index.xml","/Mellanox-NATIVE-NMST_4.14.3.3-1OEM.700.1.0.15525992_16211416.zip/metadata.zip","/Mellanox-NATIVE-NMST_4.14.3.3-1OEM.700.1.0.15525992_16211416.zip/vib20/nmst/MEL_bootbank_nmst_4.14.3.3-1OEM.700.1.0.15525992.vib","/Mellanox-NATIVE-NMST_4.14.3.3-1OEM.700.1.0.15525992_16211416.zip/metadata.zip/vendor-index.xml","/Mellanox-NATIVE-NMST_4.14.3.3-1OEM.700.1.0.15525992_16211416.zip/metadata.zip/vmware.xml","/Mellanox-NATIVE-NMST_4.14.3.3-1OEM.700.1.0.15525992_16211416.zip/metadata.zip/vibs/nmst-669545082738554545.xml","/Mellanox-NATIVE-NMST_4.14.3.3-1OEM.700.1.0.15525992_16211416.zip/metadata.zip/bulletins/Mellanox-NATIVE-NMST_4.14.3.3-1OEM.700.1.0.15525992.xml"],"md5sum":"f07a79b6541af1e195fc42da97adb0e7","name":"cp048360.zip","release":"2021-08-27T13:10:42","revision":"0","sha1sum":"d0daf811f4bbe9551933bdc469da5b84e38402ee","size":"30KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd0345028","20a6e8e4-bf33-4c71-a6bf-d9ec89537299"],"type_of_change":"1","version":"2020.11.11","vib_list":[{"name":"nmst","version":"4.14.3.3-1OEM.700.1.0.15525992"}]}],"id":{"product":"3f367d314e5844f2951b656b04957c6e","version":"15624a5662fe4359a80a4f0ef2a19177"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Remote Online:&nbsp;</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the HPE USB Key Creator Utility.&nbsp;</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux .</li>\n\t<li>cd /SPP20xxxxx and launch SUM&nbsp;(launch_sum.bat for Windows and ./launch_sum.sh for Linux).</li>\n\t<li>Select &quot;Baseline Library&quot; and wait for the Baseline inventory to complete.</li>\n\t<li>Select &quot;Nodes&quot; from the &quot;Smart Update Manager x.x.x&quot; drop down.</li>\n\t<li>Click, &quot;Add Node&quot;.\n\t<ul>\n\t\t<li>If adding a Gen9 server,\n\t\t<ul>\n\t\t\t<li>Provide IP address of the ESXi host.</li>\n\t\t\t<li>Enter&nbsp;the ESXi host credentials (root or administrator username and password)&nbsp;</li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>If adding a Gen10 and above server,\n\t\t<ul>\n\t\t\t<li>Provide iLO IP address of the ESXi host server.</li>\n\t\t\t<li>Enter the iLO credentials of the ESXi host server.</li>\n\t\t</ul>\n\t\t</li>\n\t</ul>\n\t</li>\n\t<li>Follow&nbsp;Smart Update Manager Steps and complete the driver update.&nbsp;</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware VUM or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>リモートオンライン: </strong></p>\n\n<ol>\n\t<li>HPE USB Key Creator Utilityを使用して、SPPをUSBキーにコピーします。 </li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。</li>\n\t<li>cd /SPP20xxxxx およびSUMを起動します。（Windowsの場合はlaunch_sum.bat、Linuxの場合は./launch_sum.sh）</li>\n\t<li>\"ベースラインライブラリ\"を選択し、ベースラインインベントリが完了するのを待ちます。</li>\n\t<li>\"Smart Update Manager x.x.x\"ドロップダウンから\"ノード\"を選択します。</li>\n\t<li>\"ノードの追加\"をクリックします。\n\t<ul>\n\t\t<li>Gen9サーバーを追加する場合、\n\t\t<ul>\n\t\t\t<li>ESXiホストのIPアドレスを提供します。</li>\n\t\t\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します </li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>Gen10以降のサーバーを追加する場合、\n\t\t<ul>\n\t\t\t<li>ESXiホストサーバーのiLO IPアドレスを提供します。</li>\n\t\t\t<li>ESXiホストサーバーのiLO認証情報を入力します。</li>\n\t\t</ul>\n\t\t</li>\n\t</ul>\n\t</li>\n\t<li>Smart Update Managerの指示に従い、ドライバーのアップデートを完了します。 </li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li>\n\t<li>オフラインバンドルをインストールするために、VMware VUMまたはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"net-mst kernel module driver component for VMware ESXi 7.0"},{"lang":"ja","x_late":"net-mstカーネルモジュールドライバーコンポーネントfor VMware ESXi 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"032D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-10171590032d","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30047","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"0221","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101315900221","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-07T11:39:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>NMST version&nbsp;4.14.3.3</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>NMST version&nbsp;4.14.3.3</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"","value":"HPE Apollo kl20 Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"","value":"HPE Apollo am35 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo pc40 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"","value":"HPE Apollo sx40 Server"}],"sw_keys":[{"name":"Mellanox-NATIVE-NMST:4.14.3.3-1OEM.700.1.0.15525992","sw_key_expectedpath":"driver.component:vmware:zip"},{"name":"nmst:4.14.3.3-1OEM.700.1.0.15525992","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWFVC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SEhD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3830-304a57465643","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: EG001800JWFVC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - EG001800JWFVC Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp;&nbsp; </strong>None</p>\n"}],"files":[{"bytes":"3040192","datemodified":"2021-07-24T07:27:25","file_list":["cp048459.xml","cpqsetup.exe","payload.json","setup.dll","T14SEhD4.rel"],"md5sum":"2a9409924850f918620758d1b1335d42","name":"cp048459.exe","release":"2021-07-24T07:20:09","revision":"0","sha1sum":"6a1593344f89003bee90cd3836deaee290dd9d5a","size":"2MB","target_guids":["452340a5-3047-3130-3830-304a57465643"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"55c20afa55214e04bc6d7e8985b8d0b6","version":"90340bde05c44b01b89ae3c13d825d94"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG001800JWFVC Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EG001800JWFVCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG001800JWFVC","target_guid":"452340a5-3047-3130-3830-304a57465643","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T10:15:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>A low-probability, high severity corner case of sustained outer-diameter activity with emergency power off when heads are at the outer diameter prevented heads from parking/latching properly on a few drives in the field.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001800JWFVC","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for the HPE Emulex 10/20 GbE Server Adapters for Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージは、HPE Emulex 10/20GbEサーバーアダプタードライバー for Windows Server 2019を含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"1612176","datemodified":"2020-06-12T11:09:45","file_list":["bepnic.dll","bepnic.rtf","cp044542.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll","occfg.exe","ocnd65.cat","ocnd65.inf","ocnd65.sys"],"md5sum":"3867a732a8f6d31de5b592929665fe50","name":"cp044542.exe","release":"2020-06-12T10:56:04","revision":"0","sha1sum":"2162bf360898c1fe98751a0362c0a1203bf04903","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfe4a13f6"],"type_of_change":"0","version":"12.0.1195.0"}],"id":{"product":"ee7c0fad5ff040dabc594be75871d841","version":"03f10bf622574025b711b1e94d94eee1"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex 10/20 GbE Driver for Windows Server 2019"},{"lang":"ja","x_late":"HPE Emulex 10/20 GbEドライバーfor Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"0728","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c220a","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c21d4","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072815908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-11T01:46:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now remove&nbsp;supports Synergy and Blade&nbsp;Server.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"ocnd65.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO0400KEFJB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304f-3430-304b45464a42","Version":"HPK4"},{"DeviceName":"VO1200KEFJC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314f-3230-304b45464a43","Version":"HPK4"},{"DeviceName":"VO2000KEFJD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-324f-3030-304b45464a44","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO0400KEFJB, VO1200KEFJC and VO2000KEFJD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for Windows&nbsp;(x64) - VO0400KEFJB, VO1200KEFJC and VO2000KEFJD Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"2876824","datemodified":"2021-07-25T12:15:08","file_list":["4IFDHPK4.rel","cp048476.xml","cpqsetup.exe","payload.json","setup.dll"],"md5sum":"91818df1d8d4b812bdb61ffd5debc898","name":"cp048476.exe","release":"2021-07-25T12:07:04","revision":"0","sha1sum":"d105164dbf9d52c2e476bf88136f6846aca58e1c","size":"2MB","target_guids":["002340a5-5600-304f-3430-304b45464a42","002340a5-5600-314f-3230-304b45464a43","002340a5-5600-324f-3030-304b45464a44"],"type_of_change":"1","version":"HPK4"}],"id":{"product":"e54bd80d86eb48638f965cd122dd00a1","version":"9a20a90746d5414c947982c634cce3ef"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"http://www.hpe.com/jp/servers/spp_dl\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) - VO0400KEFJB, VO1200KEFJC and VO2000KEFJD Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Windows(x64)- VO0400KEFJB、VO1200KEFJC、およびVO2000KEFJDドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VO0400KEFJB","target_guid":"002340a5-5600-304f-3430-304b45464a42","type":"nvme"},{"id":"VO1200KEFJC","target_guid":"002340a5-5600-314f-3230-304b45464a43","type":"nvme"},{"id":"VO2000KEFJD","target_guid":"002340a5-5600-324f-3030-304b45464a44","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T17:25:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for&nbsp;Microsoft Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO0400KEFJB","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO1200KEFJC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO2000KEFJD","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG0300JEHLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFLRCD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3330-304a45484c56","Version":"HPD5"},{"DeviceName":"EG0600JEHMA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFLRCD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3630-304a45484d41","Version":"HPD5"},{"DeviceName":"EG0900JEHMB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFLRCD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3930-304a45484d42","Version":"HPD5"},{"DeviceName":"EG1200JEHMC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFLRCD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3230-304a45484d43","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EG0300JEHLV, EG0600JEHMA, EG0900JEHMB, and EG1200JEHMC"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。 EG0300JEHLV、EG0600JEHMA、EG0900JEHMB、およびEG1200JEHMC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG0300JEHLV, EG0600JEHMA, EG0900JEHMB, and EG1200JEHMC Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD3</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features&nbsp;:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp;&nbsp;&nbsp; &nbsp; None</p>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"17460050","datemodified":"2021-08-30T04:59:58","file_list":["/CP048261_BUILD_3.data","/CP048261.vmexe","/CP048261.vmexe64","/CP048261.vmfile","/CP048261_VMw.zip","/CP048261.xml","/payload.json","/CP048261_VMw.zip/index.xml","/CP048261_VMw.zip/vendor-index.xml","/CP048261_VMw.zip/metadata.zip","/CP048261_VMw.zip/vib20/CP048261/HPE_bootbank_CP048261_HPD5.3-7.0.0.15843807.vib","/CP048261_VMw.zip/metadata.zip/vendor-index.xml","/CP048261_VMw.zip/metadata.zip/vmware.xml","/CP048261_VMw.zip/metadata.zip/vibs/CP048261--2674799031549723175.xml","/CP048261_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048261_HPD5.3-7.0.0.15843807.xml"],"md5sum":"febe461b93f3e5e2bc7572c948a2a37f","name":"CP048261.zip","release":"2021-08-30T04:54:40","revision":"0","sha1sum":"fd299a22bd2fd24016532967700827f08370d7ec","size":"16MB","target_guids":["002340a5-4500-3047-3330-304a45484c56","002340a5-4500-3047-3630-304a45484d41","002340a5-4500-3047-3930-304a45484d42","002340a5-4500-3147-3230-304a45484d43"],"type_of_change":"1","version":"HPD5","vib_list":[{"name":"CP048261","version":"HPD5.3-7.0.0.15843807"}]}],"id":{"product":"d480050a16674bf2aaea0c812270030a","version":"4189c7a5066d423e89a55e7032d92820"},"installation":{"command":"CP042538.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>Additional information to execute VIB file.</strong></p>\n\n<p><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p>             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul>\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p> </p>\n\n<p><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul>\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul>\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EG0300JEHLV, EG0600JEHMA, EG0900JEHMB, and EG1200JEHMC Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - EG0300JEHLV、EG0600JEHMA、EG0900JEHMB、およびEG1200JEHMCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG1200JEHMC","target_guid":"002340a5-4500-3147-3230-304a45484d43","type":"sas"},{"id":"EG0300JEHLV","target_guid":"002340a5-4500-3047-3330-304a45484c56","type":"sas"},{"id":"EG0600JEHMA","target_guid":"002340a5-4500-3047-3630-304a45484d41","type":"sas"},{"id":"EG0900JEHMB","target_guid":"002340a5-4500-3047-3930-304a45484d42","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-02T09:54:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG0900JEHMB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG1200JEHMC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0600JEHMA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0300JEHLV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GEXXV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRETG2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745585856","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB6000GEXXV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB6000GEXXV Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp; </strong>None</p>\n"}],"files":[{"bytes":"16951870","datemodified":"2021-08-27T07:56:45","file_list":["/CP048403_BUILD_2.data","/CP048403.vmexe","/CP048403.vmexe64","/CP048403.vmfile","/CP048403_VMw.zip","/CP048403.xml","/payload.json","/CP048403_VMw.zip/index.xml","/CP048403_VMw.zip/vendor-index.xml","/CP048403_VMw.zip/metadata.zip","/CP048403_VMw.zip/vib20/CP048403/HPE_bootbank_CP048403_HPG2.2-7.0.0.15843807.vib","/CP048403_VMw.zip/metadata.zip/vendor-index.xml","/CP048403_VMw.zip/metadata.zip/vmware.xml","/CP048403_VMw.zip/metadata.zip/vibs/CP048403--6359453495002588922.xml","/CP048403_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048403_HPG2.2-7.0.0.15843807.xml"],"md5sum":"55a78858cb3604d4a79028d36844f863","name":"CP048403.zip","release":"2021-08-27T07:51:27","revision":"0","sha1sum":"1a38c3fcb0a2b657d11a80d4908bd7a6c4f5f238","size":"16MB","target_guids":["002340a5-4d00-3642-3030-304745585856"],"type_of_change":"1","version":"HPG2","vib_list":[{"name":"CP048403","version":"HPG2.2-7.0.0.15843807"}]}],"id":{"product":"b85e73b81c5b414ba6a301b86f35ed46","version":"05706743061244c19fe7d88347a53a4e"},"installation":{"command":"CP040515.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB6000GEXXV Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB6000GEXXVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB6000GEXXV","target_guid":"002340a5-4d00-3642-3030-304745585856","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T21:27:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000GEXXV","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"The HPE Storage Fibre Channel (FC) adapter kit contains version 12.8.351.7 of the Emulex Storport driver for Extended Systems which provides Mezzanine Fibre Channel-Host Bus Adapter (HBA) driver support for HPE Storage RAID Arrays."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"2309152","datemodified":"2021-08-26T09:35:02","file_list":["cp048582.xml","cpqsetup.exe","elxdrvr-fc-12.8.351.7-13.exe","ElxStorInstaller.dll","install.xml","SysConfig.frm","SysConfig.frm.ja"],"md5sum":"72aa8ed58a30aeb7159775c37277b667","name":"cp048582.exe","release":"2021-08-26T09:32:35","revision":"0","sha1sum":"6a0623adcdd9a5b1261b88ff0b0c9661bedb4a53","size":"2MB","target_guids":[],"type_of_change":"1","version":"12.8.351.7"}],"id":{"product":"9b7863df603e46ab93cd260e4d2e6213","version":"fcf2916c70d8429684e18770378f7df8"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation.</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Mezzanine Fibre Channel Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T09:15:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to driver version&nbsp;12.8.351.7</p>\n\n<p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p>\n\n<p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p>\n\n<p>The extracted files are located:</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p>\n\n<p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2019</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"elxfc.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB1000JVYZL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3142-3030-304a56595a4c","Version":"HPD3"},{"DeviceName":"MB2000JVYZN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a56595a4e","Version":"HPD3"},{"DeviceName":"MB3000JVYZP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304a56595a50","Version":"HPD3"},{"DeviceName":"MB4000JVYZQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a56595a51","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB1000JVYZL, MB2000JVYZN, MB3000JVYZP and MB4000JVYZQ"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB1000JVYZL、MB2000JVYZN、MB3000JVYZPおよびMB4000JVYZQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp; MB1000JVYZL, MB2000JVYZN, MB3000JVYZP&nbsp;and MB4000JVYZQ Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"17374458","datemodified":"2021-08-26T18:11:30","file_list":["/CP048344_BUILD_2.data","/CP048344.vmexe","/CP048344.vmexe64","/CP048344.vmfile","/CP048344_VMw.zip","/CP048344.xml","/payload.json","/CP048344_VMw.zip/index.xml","/CP048344_VMw.zip/vendor-index.xml","/CP048344_VMw.zip/metadata.zip","/CP048344_VMw.zip/vib20/CP048344/HPE_bootbank_CP048344_HPD3.2-7.0.0.15843807.vib","/CP048344_VMw.zip/metadata.zip/vendor-index.xml","/CP048344_VMw.zip/metadata.zip/vmware.xml","/CP048344_VMw.zip/metadata.zip/vibs/CP048344-2113967309781078438.xml","/CP048344_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048344_HPD3.2-7.0.0.15843807.xml"],"md5sum":"0ae824809c0d40185520f08a6a38b110","name":"CP048344.zip","release":"2021-08-26T18:05:43","revision":"0","sha1sum":"5ea5d8f80e8102c23347a74b56d5fd4ea85e1d85","size":"16MB","target_guids":["002340a5-4d00-3142-3030-304a56595a4c","002340a5-4d00-3242-3030-304a56595a4e","002340a5-4d00-3342-3030-304a56595a50","002340a5-4d00-3442-3030-304a56595a51"],"type_of_change":"1","version":"HPD3","vib_list":[{"name":"CP048344","version":"HPD3.2-7.0.0.15843807"}]}],"id":{"product":"9e4dc8db386245f0ad4fc38aef31f547","version":"e1d90af74488425ba62f9de6ecf09896"},"installation":{"command":"CP040660.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB1000JVYZL, MB2000JVYZN, MB3000JVYZP and MB4000JVYZQ Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB1000JVYZL、MB2000JVYZN、MB3000JVYZP、およびMB4000JVYZQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB1000JVYZL","target_guid":"002340a5-4d00-3142-3030-304a56595a4c","type":"sas"},{"id":"MB2000JVYZN","target_guid":"002340a5-4d00-3242-3030-304a56595a4e","type":"sas"},{"id":"MB3000JVYZP","target_guid":"002340a5-4d00-3342-3030-304a56595a50","type":"sas"},{"id":"MB4000JVYZQ","target_guid":"002340a5-4d00-3442-3030-304a56595a51","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-06T16:16:58","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB1000JVYZL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB2000JVYZN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB3000JVYZP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB4000JVYZQ","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Emulex 10/20 GbE Server Adapters running under VMware vSphere 6.7."},{"lang":"ja","x_late":"この製品には、VMware vSphere 6.7で動作するHPE Emulex 10/20GbEサーバーアダプター用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;12.0.1216.4.</p>\n"},{"lang":"ja","x_late":"<p>この製品には、ドライバーバージョン12.0.1216.4が含まれています。</p>\n"}],"files":[{"bytes":"362699","datemodified":"2020-06-11T04:18:54","file_list":["/cp044546.xml","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/elxnet-12.0.1216.4-1OEM.670.0.0.8169922.x86_64.vib","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/doc/README.txt","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/doc/release_note_elxnet_12.0.1216.4-1OEM.670.0.0.8169922.xml","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/index.xml","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/vendor-index.xml","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/metadata.zip","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/vib20/elxnet/EMU_bootbank_elxnet_12.0.1216.4-1OEM.670.0.0.8169922.vib","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/metadata.zip/vmware.xml","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/metadata.zip/bulletins/VMW-ESX-6.7.0-elxnet-12.0.1216.4.xml","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/metadata.zip/vibs/elxnet--1134262900.xml"],"md5sum":"9b46aa68b1a2f32f667e21e0fc45326b","name":"cp044546.zip","release":"2020-06-11T04:18:10","revision":"0","sha1sum":"e9549e487bb930e39484ea94ccc9a7d88e830293","size":"354KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecbc5a6557"],"type_of_change":"0","version":"2020.09.14","vib_list":[{"name":"elxnet","version":"12.0.1216.4-1OEM.670.0.0.8169922"}]}],"id":{"product":"c154697a46644c47b9724ee0f9b7eaa4","version":"2c8b05ea902743ac927a92c715bbd21a"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバーにUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex 10/20 GbE Driver for VMware vSphere 6.7"},{"lang":"ja","x_late":"HPE Emulex 10/20 GbEドライバー for VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-11T01:46:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue vmnic flapping caused the network connectivity to be affected.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"elxnet:12.0.1216.4-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"ET000750KWJTF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICSHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3054-3030-3735-304b574a5446","Version":"4ICSHPK4"},{"DeviceName":"EO000375KWJUC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICSHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3337-354b574a5543","Version":"4ICSHPK4"},{"DeviceName":"EO000750KWTXC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICSHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3735-304b57545843","Version":"4ICSHPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: ET000750KWJTF, EO000750KWTXC and EO000375KWJUC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;NVMe SSD&nbsp;Flash Component for&nbsp;Windows (x64) - ET000750KWJTF, EO000750KWTXC and EO000375KWJUC Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp;&nbsp; 4ICSHPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; 4ICSHPK2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; 4ICSHPK2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li style=\"margin-left: 0px; margin-right: 0px;\">Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Known Issues:</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px\">&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"2832096","datemodified":"2021-07-24T10:18:01","file_list":["4ICSHPK4.rel","cp048692.xml","cpqsetup.exe","payload.json","setup.dll"],"md5sum":"d384a11a36a7f2a758435e17b42c09dc","name":"cp048692.exe","release":"2021-07-24T10:10:04","revision":"0","sha1sum":"6338186a73b1b907aad28c87899a5b0ac99b8cf7","size":"2MB","target_guids":["452340a5-3054-3030-3735-304b574a5446","452340a5-304f-3030-3337-354b574a5543","452340a5-304f-3030-3735-304b57545843"],"type_of_change":"1","version":"4ICSHPK4"}],"id":{"product":"142d96d331a04f9e847ceeb66ad042c6","version":"2342a80670484aba8e9a82749857a4d7"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/jp/servers/spp_dl\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) - ET000750KWJTF, EO000750KWTXC and EO000375KWJUC Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - ET000750KWJTF、EO000750KWTXCおよびEO000375KWJUCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"ET000750KWJTF","target_guid":"452340a5-3054-3030-3735-304b574a5446","type":"nvme"},{"id":"EO000375KWJUC","target_guid":"452340a5-304f-3030-3337-354b574a5543","type":"nvme"},{"id":"EO000750KWTXC","target_guid":"452340a5-304f-3030-3735-304b57545843","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-17T11:19:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>\n\t<p>Fixed HPK3 drive reports incorrect Device ID issue.</p>\n\t</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EO000375KWJUC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"EO000750KWTXC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"ET000750KWJTF","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000300JWFVB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SErD3.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57465642","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: EG000300JWFVB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG000300JWFVB&nbsp;Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4885942","datemodified":"2021-07-23T08:41:17","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-c5cd837c29-HPD3-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-c5cd837c29-HPD3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-c5cd837c29-HPD3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c5cd837c29-HPD3-2.1/CP047501.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-c5cd837c29-HPD3-2.1/T14SErD3.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-c5cd837c29-HPD3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c5cd837c29-HPD3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-c5cd837c29-HPD3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-c5cd837c29-HPD3-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP047501.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP047501.scexe"],"md5sum":"cfae76bfe2a9791db5017397d75cbc09","name":"firmware-hdd-c5cd837c29-HPD3-2.1.x86_64.rpm","release":"2021-07-23T08:29:06","revision":"0","sha1sum":"09ca7294526816d2c6038635df7ac4555f960853","size":"4MB","target_guids":["452340a5-3047-3030-3330-304a57465642"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"7163f5a35db04c1899f77a9e771fd83e","version":"bbe18fedac3f491a8faf79f113e76a6c"},"installation":{"command":"CP040323.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64)  - EG000300JWFVB Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - EG000300JWFVBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EG000300JWFVB","target_guid":"452340a5-3047-3030-3330-304a57465642","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-09T09:05:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>A low-probability, high severity corner case of sustained outer-diameter activity with emergency power off when heads are at the outer diameter prevented heads from parking/latching properly on a few drives in the field.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG000300JWFVB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains be2net drivers for the HPE Blade Emulex 10/20GbE Server Adapters running under Red Hat Enterprise Linux 7."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7で動作するHPE Blade Emulex 10/20GbE サーバーアダプター用のbe2netドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"104367","datemodified":"2021-07-21T18:03:02","file_list":["./etc/depmod.d/be2net.conf","./lib/modules/4.18.0-193.el8.x86_64","./lib/modules/4.18.0-193.el8.x86_64/extra","./lib/modules/4.18.0-193.el8.x86_64/extra/be2net","./lib/modules/4.18.0-193.el8.x86_64/extra/be2net/be2net.ko","./usr/share/smartupdate/kmod-be2net_bl/component.xml"],"md5sum":"70267a3653e40d1087effc997f2ea5bb","name":"kmod-be2net_bl-12.0.1342.0-1.rhel8u2.x86_64.rpm","release":"2021-07-21T17:48:19","revision":"0","sha1sum":"ce14a350232cc36fbd3af1bf2027421837ebdd6d","size":"101KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec04f7105f"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"104283","datemodified":"2021-07-21T18:00:25","file_list":["./etc/depmod.d/be2net.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/be2net","./lib/modules/4.18.0-240.el8.x86_64/extra/be2net/be2net.ko","./usr/share/smartupdate/kmod-be2net_bl/component.xml"],"md5sum":"517ba511ee3fc595ea39031c2331c589","name":"kmod-be2net_bl-12.0.1342.0-1.rhel8u3.x86_64.rpm","release":"2021-07-21T17:48:19","revision":"0","sha1sum":"32cff5b2a8e726c5b6fbe4e39810dacbb12544f6","size":"101KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec04f7105f"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"37f4d88a2594441eb8937501d8ada85b","version":"cf64c54c80fa412ba3f6336bb3b25373"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>\n\n<p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>\n\n<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>\n\n<p> </p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE Blade Emulex 10/20GbEドライバーfor Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0728","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c1935","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c1934","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-09-03T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 8, Updates 2&nbsp;and 3.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports the&nbsp;HPE ProLiant BL660c Gen9 Server.&nbsp;</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"kmod-be2net_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2net_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2net_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2net_bl","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900374","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware and boot BIOS of Emulex Mezzanine Fibre Channel host bus adapters."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5384098","datemodified":"2021-08-25T13:08:29","file_list":["/CP048577_BUILD_4.data","/CP048577.vmexe","/CP048577.vmexe64","/CP048577.vmfile","/CP048577_VMw.zip","/CP048577.xml","/payload.json","/CP048577_VMw.zip/index.xml","/CP048577_VMw.zip/vendor-index.xml","/CP048577_VMw.zip/metadata.zip","/CP048577_VMw.zip/vib20/CP048577/HPE_bootbank_CP048577_2021.10.01.4-6.7.0.7535516.vib","/CP048577_VMw.zip/metadata.zip/vendor-index.xml","/CP048577_VMw.zip/metadata.zip/vmware.xml","/CP048577_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048577_2021.10.01.4-6.7.0.7535516.xml","/CP048577_VMw.zip/metadata.zip/vibs/CP048577--4565563156136843343.xml"],"md5sum":"20985a49151f0820a64a5e3569d428df","name":"CP048577.zip","release":"2021-08-25T13:02:06","revision":"0","sha1sum":"ef74b4408fb152b20805bb0de2a8106b2da50391","size":"5MB","target_guids":[],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"CP048577","version":"2021.10.01.4-6.7.0.7535516"}]}],"id":{"product":"5cb3628c70284860b9a5224a9d546527","version":"ab2e13ed66844f26b33dac9868d78a94"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated if the ESXi host is Gen9 Server or Enter the IP or DNS address of the iLO of the ESXi host if the Sever is Gen10 and above</li>\n\t<li>Enter the ESXi host/iLO credentials (root or administrator username and password) based on Gen9/Gen10 and above</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Mezzanine Fibre Channel Host Bus Adapters for VMware vSphere  6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"20000"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T09:15:41","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This Firmware package contains following firmware versions:&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 16Gb LPe1605 Fibre Channel Host Bus Adapter for BladeSystem c-Class</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>12.8.528.12</td>\n\t\t\t<td>12.8.528.12</td>\n\t\t\t<td>12.8.528.10</td>\n\t\t\t<td>12.8.502.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"emulex","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JWKGN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAeAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574b474e","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB006000JWKGN"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB006000JWKGN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB006000JWKGN Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD1<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp; </strong>None</p>\n"}],"files":[{"bytes":"18782659","datemodified":"2021-08-30T20:20:47","file_list":["/CP048330_BUILD_2.data","/CP048330.vmexe","/CP048330.vmexe64","/CP048330.vmfile","/CP048330_VMw.zip","/CP048330.xml","/payload.json","/CP048330_VMw.zip/index.xml","/CP048330_VMw.zip/vendor-index.xml","/CP048330_VMw.zip/metadata.zip","/CP048330_VMw.zip/vib20/CP048330/HPE_bootbank_CP048330_HPD2.2-7.0.0.15843807.vib","/CP048330_VMw.zip/metadata.zip/vendor-index.xml","/CP048330_VMw.zip/metadata.zip/vmware.xml","/CP048330_VMw.zip/metadata.zip/vibs/CP048330--1759966185983670208.xml","/CP048330_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048330_HPD2.2-7.0.0.15843807.xml"],"md5sum":"7afc5c54b93c2fd06b07604ffa910143","name":"CP048330.zip","release":"2021-08-30T20:15:37","revision":"0","sha1sum":"37c64c0886d034c2d101f53b49be23f444ee25cb","size":"17MB","target_guids":["4d2340a5-3042-3630-3030-304a574b474e"],"type_of_change":"1","version":"HPD2","vib_list":[{"name":"CP048330","version":"HPD2.2-7.0.0.15843807"}]}],"id":{"product":"3fba85b34f854c9b9b5bb51030ba5e41","version":"afbad0c53f54434bb2d7bbaec80475ea"},"installation":{"command":"CP041489.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB006000JWKGN Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB006000JWKGNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB006000JWKGN","target_guid":"4d2340a5-3042-3630-3030-304a574b474e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-05T18:35:16","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000JWKGN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO0800JEFPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304f-3830-304a45465046","Version":"HPD3"},{"DeviceName":"EO0400JEFPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304f-3430-304a45465045","Version":"HPD3"},{"DeviceName":"EO0200JEFPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304f-3230-304a45465044","Version":"HPD3"},{"DeviceName":"MO1600JEFPC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304a45465043","Version":"HPD3"},{"DeviceName":"MO0800JEFPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3830-304a45465042","Version":"HPD3"},{"DeviceName":"MO0400JEFPA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3430-304a45465041","Version":"HPD3"},{"DeviceName":"MO0200JEFNV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3230-304a45464e56","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MO0200JEFNV, MO0400JEFPA, MO0800JEFPB, MO1600JEFPC, EO0200JEFPD, EO0400JEFPE and EO0800JEFPF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MO0200JEFNV, MO0400JEFPA, MO0800JEFPB, MO1600JEFPC, EO0200JEFPD, EO0400JEFPE and EO0800JEFPF Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong>&nbsp;&nbsp;&nbsp;&nbsp;<br />\n&nbsp; &nbsp; &nbsp; None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3341296","datemodified":"2021-07-25T17:59:50","file_list":["cp048630.xml","cpqsetup.exe","HSSCPCD3.rel","payload.json","setup.dll"],"md5sum":"7fd06f958b1c94b1731b52f51a8286d0","name":"cp048630.exe","release":"2021-07-25T17:52:05","revision":"0","sha1sum":"476838d0cd4ef35721ba608f42a6b3bacaa05b39","size":"3MB","target_guids":["002340a5-4500-304f-3830-304a45465046","002340a5-4500-304f-3430-304a45465045","002340a5-4500-304f-3230-304a45465044","002340a5-4d00-314f-3630-304a45465043","002340a5-4d00-304f-3830-304a45465042","002340a5-4d00-304f-3430-304a45465041","002340a5-4d00-304f-3230-304a45464e56"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"5c9d950d613945119a93065a8b8651f2","version":"8de63901a764465b9db3e7e99fd8f5ad"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MO0200JEFNV, MO0400JEFPA, MO0800JEFPB, MO1600JEFPC, EO0200JEFPD, EO0400JEFPE and EO0800JEFPF Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MO0200JEFNV、MO0400JEFPA、MO0800JEFPB、MO1600JEFPC、EO0200JEFPD、EO0400JEFPE、およびEO0800JEFPFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EO0800JEFPF","target_guid":"002340a5-4500-304f-3830-304a45465046","type":"sas"},{"id":"MO1600JEFPC","target_guid":"002340a5-4d00-314f-3630-304a45465043","type":"sas"},{"id":"EO0200JEFPD","target_guid":"002340a5-4500-304f-3230-304a45465044","type":"sas"},{"id":"MO0200JEFNV","target_guid":"002340a5-4d00-304f-3230-304a45464e56","type":"sas"},{"id":"EO0400JEFPE","target_guid":"002340a5-4500-304f-3430-304a45465045","type":"sas"},{"id":"MO0400JEFPA","target_guid":"002340a5-4d00-304f-3430-304a45465041","type":"sas"},{"id":"MO0800JEFPB","target_guid":"002340a5-4d00-304f-3830-304a45465042","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T14:18:07","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EO0200JEFPD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO0400JEFPE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO0800JEFPF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO0200JEFNV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO1600JEFPC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO0800JEFPB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO0400JEFPA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the HPE Blade QLogic userspace IO daemon that provides ARP/DHCP support for iSCSI offload for Blade QLogic NX2 Multifunction Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 15 SP1."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15 SP1で動作するBlade QLogicマルチファンクションGigabit Ethernet NICのiSCSIオフロード用のARP/DHCPサポートを提供するHPE Blade QLogic userspace IO Daemonが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"99628","datemodified":"2020-02-12T18:46:21","file_list":["./etc/logrotate.d/iscsiuiolog","./sbin/iscsiuio","./usr/lib/.build-id","./usr/lib/.build-id/85","./usr/lib/.build-id/85/c3cfa1e86cfabbf8aae2b9075be2b98b9f29d2","./usr/share/man/man8/iscsiuio.8.gz","./usr/share/smartupdate/iscsiuio_bl/component.xml"],"md5sum":"fd97603fda31237994a666c33ef170e6","name":"iscsiuio_bl-2.11.5.13-3.sles15sp1.x86_64.rpm","release":"2020-02-12T18:45:06","revision":"0","sha1sum":"a46e773cf9f039fd6a4e42a1cae2dcdd489dc6fc","size":"97KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf9413ac8"],"type_of_change":"0","version":"2.11.5.13-3"}],"id":{"product":"48c9c127d8e84c96aa3d591f450ace21","version":"556182e6fc1246258154795ae211f65c"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"},{"lang":"ja","x_late":"<p>インストールのノートについてREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade QLogic NX2 iSCSI Offload IO Daemon for SUSE Linux Enterprise Server 15 SP1"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"168E","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1933","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c22fa","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1917","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1916","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1933","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c22fa","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1916","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1917","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-03-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product has&nbsp;been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"iscsiuio_bl","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Blade Intel ixgbe Ethernet NICs running under SUSE Linux Enterprise Server 12."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12で動作するHPE Blade Intel ixgbe Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"4216191","datemodified":"2021-03-08T18:14:03","file_list":["./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/hp-ixgbe","./lib/modules/4.12.14-120-default/updates/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/hp-ixgbe_bl-kmp-default/component.xml"],"md5sum":"203b91ac5167e02c38e1de393b0cc8cc","name":"hp-ixgbe_bl-kmp-default-5.9.4_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-03-08T18:04:08","revision":"0","sha1sum":"8d5cc710beefa743ae2adda67fa78b8f8a0360c8","size":"4MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf57995ac"],"type_of_change":"0","version":"5.9.4-1"},{"bytes":"4099344","datemodified":"2021-03-08T18:15:23","file_list":["./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/hp-ixgbe","./lib/modules/4.12.14-94.41-default/updates/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/hp-ixgbe_bl-kmp-default/component.xml"],"md5sum":"a339e4390c75808ef95dae101c437133","name":"hp-ixgbe_bl-kmp-default-5.9.4_k4.12.14_94.41-1.sles12sp4.x86_64.rpm","release":"2021-03-08T18:04:08","revision":"0","sha1sum":"c8ddbf34e027cc801dcab7917bd100c63f5268fb","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf57995ac"],"type_of_change":"0","version":"5.9.4-1"}],"id":{"product":"5eee6ab16a2542c6ab8115b98b119c8f","version":"de1c9c07fe0f4f4d834b26da4175dabe"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Intel ixgbe Drivers for SUSE Linux Enterprise Server 12"},{"lang":"ja","x_late":"HPE Blade Intel ixgbeドライバーfor SUSE Linux Enterprise Server 12"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c18d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>These drivers have been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 12 SP5.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"hp-ixgbe_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbe_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbe_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbe_bl-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built for SUSE Linux Enterprise Server 15 (64-bit) to enable the HPE Smart Array B140i SATA RAID controller."},{"lang":"ja","x_late":"このRPMを使用して、HPE Smart Array B140i SATA RAIDコントローラーを有効にする、64-bit SUSE LINUX Enterprise Server 15用のビルド済みバイナリドライバーモジュールを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"1017071","datemodified":"2021-06-08T11:01:22","file_list":["./etc/dracut.conf.d/hpdsa.conf","./lib/modules/5.3.18-57-default","./lib/modules/5.3.18-57-default/updates","./lib/modules/5.3.18-57-default/updates/hpdsa.ko","./usr/share/smartupdate/hpdsa-kmp-default/component.xml"],"md5sum":"6702f7954714744fe2ecd08c60c9e9c8","name":"hpdsa-kmp-default-1.2.10-196.sles15sp3.x86_64.rpm","release":"2021-06-08T10:53:04","revision":"0","sha1sum":"358c5ccc4132fc791f55d82307019bdcc3213135","size":"0MB","target_guids":[],"type_of_change":"1","version":"1.2.10-196"},{"bytes":"1019756","datemodified":"2021-06-08T11:02:44","file_list":["./etc/dracut.conf.d/hpdsa.conf","./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/hpdsa.ko","./usr/share/smartupdate/hpdsa-kmp-default/component.xml"],"md5sum":"b13820f1f9d642c546ea592db366ff3f","name":"hpdsa-kmp-default-1.2.10-196.sles15sp2.x86_64.rpm","release":"2021-06-08T10:53:04","revision":"0","sha1sum":"5b01cf9ff5f071158879fb177164f72067ed70ca","size":"0MB","target_guids":[],"type_of_change":"1","version":"1.2.10-196"}],"id":{"product":"f0faaea8688741debca7931ae839b647","version":"0b16826bd96243808757081ffa810b3c"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as the system administrator (root), download the RPM to a directory on<br />\nyour hard drive and change to that directory.</p>\n\n<p dir=\"ltr\"><strong>To install&nbsp;or&nbsp;upgrade&nbsp;the driver type:</strong></p>\n\n<p># rpm -Uvh hpdsa-kmp-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</p>\n\n<p>Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p dir=\"ltr\">NOTE: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:</p>\n\n<p dir=\"ltr\"># rpm -e hpdsa-kmp-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</p>\n\n<p dir=\"ltr\"><strong><u>Enterprise Support</u></strong><br />\nFor support on Smart Array controllers, visit&nbsp;<a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a></p>\n"},{"lang":"ja","x_late":"<p>システム管理者（root）としてログインし、RPMを<br />\nご使用のハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</p>\n\n<p dir=\"ltr\"><strong>ドライバーをインストールまたはアップグレードするには次のようにタイプします。</strong></p>\n\n<p># rpm -Uvh hpdsa-kmp-<version>.<OSupdate>.x86_64.rpm</p>\n\n<p>Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p dir=\"ltr\">注記：インストールの失敗、あるいは警告やエラーメッセージを表示して停止した場合は、コンピューターを再起動しないでください。ドライバーは動作しないため、以下のコマンドをタイプしてアンインストールしてください。</p>\n\n<p dir=\"ltr\"># rpm -e hpdsa-kmp-<version>.<OSupdate>.x86_64.rpm</p>\n\n<p dir=\"ltr\"><strong><u>Enterprise Support</u></strong><br />\nSmartアレイコントローラーのサポートに関しては、<a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a>を参照してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Dynamic Smart Array B140i SATA RAID Controller Driver for SUSE LINUX Enterprise Server 15 (64-bit)"},{"lang":"ja","x_late":"SUSE LINUX Enterprise Server 15(64-bit)用HPE Dynamic SmartアレイB140i SATA RAIDコントローラードライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"8D66","subdev":"009D","subven":"1590","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T06:37:01","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Add support for SUSE Linux Enterprise Services 15 SP2</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Add support for SUSE Linux Enterprise Services 15 SP2</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U25","value":"HP ProLiant XL280d Accelerator Tray - cancelled"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"hpdsa-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hpdsa-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hpdsa-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hpdsa-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MR000240GWFLU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3234-304757464c55","Version":"HPGG"},{"DeviceName":"MR000480GWFLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3438-304757464c56","Version":"HPGG"},{"DeviceName":"VR000480GWFMD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3438-304757464d44","Version":"HPGG"},{"DeviceName":"MR000960GWFMA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3936-304757464d41","Version":"HPGG"},{"DeviceName":"VR000960GWFME","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3936-304757464d45","Version":"HPGG"},{"DeviceName":"MR001920GWFMB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3130-3932-304757464d42","Version":"HPGG"},{"DeviceName":"VR001920GWFMC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3130-3932-304757464d43","Version":"HPGG"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MR000240GWFLU, MR000480GWFLV, VR000480GWFMD, MR000960GWFMA, VR000960GWFME, MR001920GWFMB and VR001920GWFMC Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MR000240GWFLU、MR000480GWFLV、VR000480GWFMD、MR000960GWFMA、VR000960GWFME、MR001920GWFMB VR001920GWFMC ドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64)&nbsp;- MR000240GWFLU, MR000480GWFLV, VR000480GWFMD, MR000960GWFMA, VR000960GWFME, MR001920GWFMB and VR001920GWFMC Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGG<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGE<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPGE</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3132624","datemodified":"2021-07-25T18:00:29","file_list":["cp048632.xml","cpqsetup.exe","M5100MGG.rel","payload.json","setup.dll"],"md5sum":"dee77b944c43493e9c0e3530c47dd4c8","name":"cp048632.exe","release":"2021-07-25T17:53:04","revision":"0","sha1sum":"f92a635eb348705fb31095ead9b1952dce622f0b","size":"2MB","target_guids":["4d2340a5-3052-3030-3234-304757464c55","4d2340a5-3052-3030-3438-304757464c56","562340a5-3052-3030-3438-304757464d44","4d2340a5-3052-3030-3936-304757464d41","562340a5-3052-3030-3936-304757464d45","4d2340a5-3052-3130-3932-304757464d42","562340a5-3052-3130-3932-304757464d43"],"type_of_change":"1","version":"HPGG"}],"id":{"product":"acb1ff6d668a45ae89fbb3be24e50b7f","version":"a7efc55b6b4d45edb726f1045fbb160b"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MR000240GWFLU, MR000480GWFLV, VR000480GWFMD, MR000960GWFMA, VR000960GWFME, MR001920GWFMB and VR001920GWFMC Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MR000240GWFLU、MR000480GWFLV、VR000480GWFMD、MR000960GWFMA、VR000960GWFME、MR001920GWFMB、およびVR001920GWFMCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MR001920GWFMB","target_guid":"4d2340a5-3052-3130-3932-304757464d42","type":"sata"},{"id":"VR001920GWFMC","target_guid":"562340a5-3052-3130-3932-304757464d43","type":"sata"},{"id":"MR000240GWFLU","target_guid":"4d2340a5-3052-3030-3234-304757464c55","type":"sata"},{"id":"MR000480GWFLV","target_guid":"4d2340a5-3052-3030-3438-304757464c56","type":"sata"},{"id":"VR000480GWFMD","target_guid":"562340a5-3052-3030-3438-304757464d44","type":"sata"},{"id":"MR000960GWFMA","target_guid":"4d2340a5-3052-3030-3936-304757464d41","type":"sata"},{"id":"VR000960GWFME","target_guid":"562340a5-3052-3030-3936-304757464d45","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T14:34:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Improvements to Product Quality and Reliability.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MR000480GWFLV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MR000960GWFMA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VR001920GWFMC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VR000960GWFME","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MR001920GWFMB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VR000480GWFMD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MR000240GWFLU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GVYZB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPETG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304756595a42","Version":"HPG4"},{"DeviceName":"MB4000GVYZA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPETG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304756595a41","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB6000GVYZB and MB4000GVYZA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB6000GVYZB and MB4000GVYZA Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None.</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"17238411","datemodified":"2021-08-26T20:48:52","file_list":["/CP048377_BUILD_2.data","/CP048377.vmexe","/CP048377.vmexe64","/CP048377.vmfile","/CP048377_VMw.zip","/CP048377.xml","/payload.json","/CP048377_VMw.zip/index.xml","/CP048377_VMw.zip/vendor-index.xml","/CP048377_VMw.zip/metadata.zip","/CP048377_VMw.zip/vib20/CP048377/HPE_bootbank_CP048377_HPG4.2-7.0.0.15843807.vib","/CP048377_VMw.zip/metadata.zip/vendor-index.xml","/CP048377_VMw.zip/metadata.zip/vmware.xml","/CP048377_VMw.zip/metadata.zip/vibs/CP048377-8393986470591433366.xml","/CP048377_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048377_HPG4.2-7.0.0.15843807.xml"],"md5sum":"ef46350f89f570bb238369269712d179","name":"CP048377.zip","release":"2021-08-26T20:43:40","revision":"0","sha1sum":"463fe32444412e8f48ac63358e796fb2773915ed","size":"16MB","target_guids":["002340a5-4d00-3642-3030-304756595a42","002340a5-4d00-3442-3030-304756595a41"],"type_of_change":"1","version":"HPG4","vib_list":[{"name":"CP048377","version":"HPG4.2-7.0.0.15843807"}]}],"id":{"product":"474dacedc05a47e69c05eb6235e4913d","version":"47b7546d1533489ca98cd9f2bd79f80b"},"installation":{"command":"CP040687.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB6000GVYZB and MB4000GVYZA Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB6000GVYZBおよびMB4000GVYZAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB4000GVYZA","target_guid":"002340a5-4d00-3442-3030-304756595a41","type":"sata"},{"id":"MB6000GVYZB","target_guid":"002340a5-4d00-3642-3030-304756595a42","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T07:19:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000GVYZB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB4000GVYZA","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"Online ROM Flash Smart Component which upgrades the switch firmware on the HPE Express Bay Enablement Switch Card"},{"lang":"cn","x_late":"可更新 HPE Express 托架支持交换卡上的交换机固件的在线 ROM 刷新组件"},{"lang":"tw","x_late":"可升級 HPE Express 插槽啟用交換器卡的交換器韌體的線上 ROM 更新智慧型元件"},{"lang":"ko","x_late":"HPE Express Bay Enablement Switch Card에서 스위치 펌웨어를 업그레이드하는 온라인 ROM 플래시 스마트 구성 요소"},{"lang":"ja","x_late":"HPE Express Bay Enablement Switch カード上のスイッチファームウェアをアップグレードする、オンラインROMフラッシュスマートコンポーネント"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"cn","x_late":"服务器选项"},{"lang":"ja","x_late":"サーバ オプション"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online ROM Flash Component for VMware ESXi - HPE Express Bay Enablement Switch Card</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 1.78 (B)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.78<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 1.78<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;Added VMware vSphere 7.0 OS support</p>\n\n<p><strong>Problems Fixed in version 1.78:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"1192784","datemodified":"2020-06-20T12:28:48","file_list":["/CP044313.vmexe","/CP044313.vmexe64","/CP044313.vmfile","/CP044313.xml","/payload.json","/README.txt"],"md5sum":"a7851f2fd3ad3bbe1f20e103e572b58a","name":"CP044313.zip","release":"2020-06-20T12:23:05","revision":"0","sha1sum":"395c9568b623c4406f4db41c19d2d36156aae8f6","size":"1MB","target_guids":[],"type_of_change":"0","version":"1.78","vib_list":[]}],"id":{"product":"6d91322ca9b048648de88ccf34f795c6","version":"718cc4b1e62849019cf3cb69227d5ddf"},"installation":{"command":"CP044313.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><u>Power cycle / cold reboot is required after installation for updates to take effect.</u></p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a>&nbsp;on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at: <a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n<strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Smart Component zip file in a temporary directory</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system for the firmware update to take effect</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware ESXi - HPE Express Bay Enablement Switch Card"},{"lang":"cn","x_late":"VMware ESXi版在线ROM刷新组件 - HPE Express托架支持交换卡"},{"lang":"tw","x_late":"適用於 VMware ESXi 的線上 ROM 更新元件 – HPE Express 插槽啟用交換器卡"},{"lang":"ko","x_late":"VMware ESXi용 온라인 ROM 플래시 구성요소 - HPE 익스프레스 베이 인에이블먼트 스위치 카드"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for VMware ESXi - HPE Express Bay Enablement Switchカード"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-06-07T12:11:07","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added VMware vSphere 6.7 OS support</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added support for the ESXi OS 7.0 changes</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"}],"sw_keys":[{"name":"HP Gen9 ExpressBay 6SFF Drive Cage","sw_key_expectedpath":"firmware:sd:switchbackplane"},{"name":"HP G9 Express Bay 6 SFF Drive Cage","sw_key_expectedpath":"firmware:sd:switchbackplane"},{"name":"HP Gen9 ExpressBay 5SFF Drive Cage","sw_key_expectedpath":"firmware:sd:switchbackplane"},{"name":"HP G9 Express Bay 5 SFF Drive Cage","sw_key_expectedpath":"firmware:sd:switchbackplane"},{"name":"DL360p Gen9 2SFF ExpressBay Bkpln","sw_key_expectedpath":"firmware:sd:switchbackplane"},{"name":"DL360 Gen9 8SFF 4PCIe+4SAS Bkpln","sw_key_expectedpath":"firmware:sd:switchbackplane"},{"name":"HP Express Bay 6 HDD Switch Card","sw_key_expectedpath":"firmware:sd:switchbackplane"},{"name":"HP DL360G9 2 SFF Express Bay Drive Cage","sw_key_expectedpath":"firmware:sd:switchbackplane"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware for Converged Network and Network only adapters. "}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"12900456","datemodified":"2021-08-25T12:09:02","file_list":["/CP048537_BUILD_4.data","/CP048537.vmexe","/CP048537.vmexe64","/CP048537.vmfile","/CP048537_VMw.zip","/CP048537.xml","/payload.json","/CP048537_VMw.zip/index.xml","/CP048537_VMw.zip/vendor-index.xml","/CP048537_VMw.zip/metadata.zip","/CP048537_VMw.zip/vib20/CP048537/HPE_bootbank_CP048537_2021.10.01.4-6.7.0.7535516.vib","/CP048537_VMw.zip/metadata.zip/vendor-index.xml","/CP048537_VMw.zip/metadata.zip/vmware.xml","/CP048537_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048537_2021.10.01.4-6.7.0.7535516.xml","/CP048537_VMw.zip/metadata.zip/vibs/CP048537-923981841858770821.xml"],"md5sum":"2c4c1b671da09145ffd47e6dc23c06c1","name":"CP048537.zip","release":"2021-08-25T12:03:11","revision":"0","sha1sum":"14921eeda0e4c20b143e91a5587033a73df385fd","size":"12MB","target_guids":[],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"CP048537","version":"2021.10.01.4-6.7.0.7535516"}]}],"id":{"product":"4570b023149a4880bbf9ca19e7db01f6","version":"b6db538e52274a4d82635738ec4f8bcc"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the&nbsp;Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, <strong>if the component is supported by SUM but is not yet part of an SPP:</strong></strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Converged Network Adapters for VMware vSphere  6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"20000"},"supported_devices":[{"dev":"0724","subdev":"21D4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"21D4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"8153","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8153","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8144","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"8144","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"220A","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"220A","subven":"103C","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T11:00:55","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This Firmware package contains following firmware version:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:800px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot BIOS</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 10Gb 2-port 556FLR-T Adapter</td>\n\t\t\t<td>10Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1345.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</td>\n\t\t\t<td>10Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1345.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE CN1200E Dual Port Converged Network Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1345.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE&nbsp;CN1200E-T Dual Port Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1345.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"}],"sw_keys":[{"name":"emulex_cna","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWWQH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757575148","Version":"HPG3"},{"DeviceName":"MB002000GWWQF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757575146","Version":"HPG3"},{"DeviceName":"MB001000GWWQE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757575145","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB004000GWWQH, MB002000GWWQF and MB001000GWWQE"},{"lang":"ja","x_late":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB004000GWWQH、MB002000GWWQF、およびMB001000GWWQE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG2</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG2<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"3658616","datemodified":"2021-07-25T20:42:09","file_list":["cp048652.xml","cpqsetup.exe","payload.json","SCIMARRNNTG3.rel","setup.dll"],"md5sum":"bb1a9c5a3f120629351410e274c96643","name":"cp048652.exe","release":"2021-07-25T20:35:10","revision":"0","sha1sum":"9e659c906e53193ae1305a3e99ceae1581eecf1b","size":"3MB","target_guids":["4d2340a5-3042-3430-3030-304757575148","4d2340a5-3042-3230-3030-304757575146","4d2340a5-3042-3130-3030-304757575145"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"260b73b77b824e60a7231a400ce24c25","version":"f9ecd669500a4bb386cf0a61bf546cd9"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for Windows (x64) - MB004000GWWQH、MB002000GWWQF、およびMB001000GWWQEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB004000GWWQH","target_guid":"4d2340a5-3042-3430-3030-304757575148","type":"sata"},{"id":"MB002000GWWQF","target_guid":"4d2340a5-3042-3230-3030-304757575146","type":"sata"},{"id":"MB001000GWWQE","target_guid":"4d2340a5-3042-3130-3030-304757575145","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T18:54:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB001000GWWQE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB002000GWWQF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB004000GWWQH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH0300JDYTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFLRCD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3330-304a44595448","Version":"HPD6"},{"DeviceName":"EH0450JDYTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFLRCD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3435-304a4459544b","Version":"HPD6"},{"DeviceName":"EH0600JDYTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFLRCD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3630-304a4459544c","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EH0300JDYTH, EH0450JDYTK and EH0600JDYTL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EH0300JDYTH, EH0450JDYTK&nbsp;and EH0600JDYTL Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong>&nbsp;&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None.</p>\n"}],"files":[{"bytes":"17518901","datemodified":"2021-08-30T06:42:08","file_list":["/CP048292_BUILD_2.data","/CP048292.vmexe","/CP048292.vmexe64","/CP048292.vmfile","/CP048292_VMw.zip","/CP048292.xml","/payload.json","/CP048292_VMw.zip/index.xml","/CP048292_VMw.zip/vendor-index.xml","/CP048292_VMw.zip/metadata.zip","/CP048292_VMw.zip/vib20/CP048292/HPE_bootbank_CP048292_HPD6.2-7.0.0.15843807.vib","/CP048292_VMw.zip/metadata.zip/vendor-index.xml","/CP048292_VMw.zip/metadata.zip/vmware.xml","/CP048292_VMw.zip/metadata.zip/vibs/CP048292--3310962060742691239.xml","/CP048292_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048292_HPD6.2-7.0.0.15843807.xml"],"md5sum":"da3ccd14e2785f8dd5a7da8e60bed85d","name":"CP048292.zip","release":"2021-08-30T06:37:04","revision":"0","sha1sum":"758f0f3b1e01238b137c85e666ac93b179338d33","size":"16MB","target_guids":["002340a5-4500-3048-3330-304a44595448","002340a5-4500-3048-3435-304a4459544b","002340a5-4500-3048-3630-304a4459544c"],"type_of_change":"1","version":"HPD6","vib_list":[{"name":"CP048292","version":"HPD6.2-7.0.0.15843807"}]}],"id":{"product":"2311760d35054ca48230493dff4b743b","version":"76c8094b7d2b4dd4a5e077f3d1c942a1"},"installation":{"command":"CP042726.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EH0300JDYTH, EH0450JDYTK and EH0600JDYTL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - EH0300JDYTH、EH0450JDYTK、およびEH0600JDYTLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EH0300JDYTH","target_guid":"002340a5-4500-3048-3330-304a44595448","type":"sas"},{"id":"EH0450JDYTK","target_guid":"002340a5-4500-3048-3435-304a4459544b","type":"sas"},{"id":"EH0600JDYTL","target_guid":"002340a5-4500-3048-3630-304a4459544c","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-03T07:31:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH0600JDYTL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0300JDYTH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0450JDYTK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GEQUT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHc8HaoeFGB.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745515554","Version":"HPGB"},{"DeviceName":"MB8000GEQUU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHc8HaoeFGB.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3842-3030-304745515555","Version":"HPGB"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB6000GEQUT and MB8000GEQUU"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB6000GEQUT and MB8000GEQUU Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGB<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG7</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.&nbsp; This issue was only found during supplier ongoing reliability testing.</li>\n\t<li>Online firmware update fails when drives are connected behind AHCI controller.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"17559937","datemodified":"2021-08-26T20:31:26","file_list":["/CP048371_BUILD_2.data","/CP048371.vmexe","/CP048371.vmexe64","/CP048371.vmfile","/CP048371_VMw.zip","/CP048371.xml","/payload.json","/CP048371_VMw.zip/index.xml","/CP048371_VMw.zip/vendor-index.xml","/CP048371_VMw.zip/metadata.zip","/CP048371_VMw.zip/vib20/CP048371/HPE_bootbank_CP048371_HPGB.2-7.0.0.15843807.vib","/CP048371_VMw.zip/metadata.zip/vendor-index.xml","/CP048371_VMw.zip/metadata.zip/vmware.xml","/CP048371_VMw.zip/metadata.zip/vibs/CP048371--6397431421621867534.xml","/CP048371_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048371_HPGB.2-7.0.0.15843807.xml"],"md5sum":"92e383ad30c7cb975095f024881cb734","name":"CP048371.zip","release":"2021-08-26T20:26:08","revision":"0","sha1sum":"19ee148fd3af5685f4f6298ee68aef35aca10775","size":"16MB","target_guids":["002340a5-4d00-3642-3030-304745515554","002340a5-4d00-3842-3030-304745515555"],"type_of_change":"2","version":"HPGB","vib_list":[{"name":"CP048371","version":"HPGB.2-7.0.0.15843807"}]}],"id":{"product":"ef9e3c99746c4ae380ca5d0cac6d2b97","version":"b90cbdbf0f224b70a65964f41155a0c1"},"installation":{"command":"CP040632.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB6000GEQUT and MB8000GEQUU Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB6000GEQUTおよびMB8000GEQUUドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB8000GEQUU","target_guid":"002340a5-4d00-3842-3030-304745515555","type":"sata"},{"id":"MB6000GEQUT","target_guid":"002340a5-4d00-3642-3030-304745515554","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-07T21:10:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was only found during supplier ongoing reliability testing.</li>\n\t<li>Online firmware update fails when drives are connected behind AHCI controller.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was only found during supplier ongoing reliability testing.</li>\n\t<li>Online firmware update fails when drives are connected behind AHCI controller.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB8000GEQUU","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB6000GEQUT","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXL5800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3830-3048d90154e8","Version":"MPK75H5Q"},{"DeviceName":"MZXL51T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3154-36487a9b1618","Version":"MPK75H5Q"},{"DeviceName":"MZXL53T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3354-324884d9e9f5","Version":"MPK75H5Q"},{"DeviceName":"MZXL56T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3654-34482ab7fb8f","Version":"MPK75H5Q"},{"DeviceName":"MZXL512THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3132-544895b51a17","Version":"MPK75H5Q"},{"DeviceName":"MZXL5960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3936-304894dc03d2","Version":"MPK75H5Q"},{"DeviceName":"MZXL51T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3154-3948e450274f","Version":"MPK75H5Q"},{"DeviceName":"MZXL53T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3354-38483310a47b","Version":"MPK75H5Q"},{"DeviceName":"MZXL57T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3754-364820f1a5c1","Version":"MPK75H5Q"},{"DeviceName":"MZXL515THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3135-54486d0092b3","Version":"MPK75H5Q"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-000H3"},{"lang":"ja","x_late":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MZXL5800HBHQ-000H3、MZXL51T6HBJR-000H3、MZXL53T2HBLS-000H3、MZXL56T4HALA-000H3、MZXL512THALA-000H3、MZXL5960HBHQ-000H3、MZXL51T9HBJR-000H3、MZXL51T9HBJR-000H3、MZXL53"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows&nbsp;(x64) - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-000H3&nbsp; Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>MPK75H5Q</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; MPK73H5Q</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; MPK73H5Q</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Fixed False UECC issue at idle power mode (12.8TB and 15.36TB only).</li>\n\t<li>Apply PCLK running PHY option, PLL clock disable can be avoided in lane 0 missing case.</li>\n\t<li>Old FW download Blocking.</li>\n\t<li>FW is changed off the option of TX data alignment for each lane.</li>\n\t<li>FW is changed to clear the interrupt after TLP Complete when PCIe config read operation.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us\" style=\"color: rgb(5, 99, 193); text-decoration: underline;\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"7693496","datemodified":"2021-07-24T08:54:23","file_list":["cp048464.xml","cpqsetup.exe","MPK75H5Q.rel","payload.json","setup.dll"],"md5sum":"981549506c99edef2b742d1928260142","name":"cp048464.exe","release":"2021-07-24T08:47:05","revision":"0","sha1sum":"456cdb2a9d8f0c2b502d38a820d8b0e72cebf068","size":"7MB","target_guids":["4d2340a5-585a-354c-3830-3048d90154e8","4d2340a5-585a-354c-3154-36487a9b1618","4d2340a5-585a-354c-3354-324884d9e9f5","4d2340a5-585a-354c-3654-34482ab7fb8f","4d2340a5-585a-354c-3132-544895b51a17","4d2340a5-585a-354c-3936-304894dc03d2","4d2340a5-585a-354c-3154-3948e450274f","4d2340a5-585a-354c-3354-38483310a47b","4d2340a5-585a-354c-3754-364820f1a5c1","4d2340a5-585a-354c-3135-54486d0092b3"],"type_of_change":"2","version":"MPK75H5Q"}],"id":{"product":"459b31cbafbe408eaf0a96421248c984","version":"d1e0b3d3b2eb4b00a174b1c57df26e3a"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-0 Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - MZXL5800HBHQ-000H3、MZXL51T6HBJR-000H3、MZXL53T2HBLS-000H3、MZXL56T4HALA-000H3、MZXL512THALA-000H3、 MZXL5960HBHQ-000H3、MZXL51T9HBJR-000H3、MZXL53T8HBLS-000H3、MZXL57T6HALA-000H3および MZXL515THALA-0ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MZXL5960HBHQ-000H3","target_guid":"4d2340a5-585a-354c-3936-304894dc03d2","type":"nvme"},{"id":"MZXL515THALA-000H3","target_guid":"4d2340a5-585a-354c-3135-54486d0092b3","type":"nvme"},{"id":"MZXL512THALA-000H3","target_guid":"4d2340a5-585a-354c-3132-544895b51a17","type":"nvme"},{"id":"MZXL57T6HALA-000H3","target_guid":"4d2340a5-585a-354c-3754-364820f1a5c1","type":"nvme"},{"id":"MZXL56T4HALA-000H3","target_guid":"4d2340a5-585a-354c-3654-34482ab7fb8f","type":"nvme"},{"id":"MZXL53T8HBLS-000H3","target_guid":"4d2340a5-585a-354c-3354-38483310a47b","type":"nvme"},{"id":"MZXL53T2HBLS-000H3","target_guid":"4d2340a5-585a-354c-3354-324884d9e9f5","type":"nvme"},{"id":"MZXL51T6HBJR-000H3","target_guid":"4d2340a5-585a-354c-3154-36487a9b1618","type":"nvme"},{"id":"MZXL5800HBHQ-000H3","target_guid":"4d2340a5-585a-354c-3830-3048d90154e8","type":"nvme"},{"id":"MZXL51T9HBJR-000H3","target_guid":"4d2340a5-585a-354c-3154-3948e450274f","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T12:17:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Fixed False UECC issue at idle power mode (12.8TB and 15.36TB only).</li>\n\t<li>Apply PCLK running PHY option, PLL clock disable can be avoided in lane 0 missing case.</li>\n\t<li>Old FW download Blocking.</li>\n\t<li>FW is changed off the option of TX data alignment for each lane.</li>\n\t<li>FW is changed to clear the interrupt after TLP Complete when PCIe config read operation.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us\" style=\"color: rgb(5, 99, 193); text-decoration: underline;\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us</a></li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Fixed False UECC issue at idle power mode (12.8TB and 15.36TB only).</li>\n\t<li>Apply PCLK running PHY option, PLL clock disable can be avoided in lane 0 missing case.</li>\n\t<li>Old FW download Blocking.</li>\n\t<li>FW is changed off the option of TX data alignment for each lane.</li>\n\t<li>FW is changed to clear the interrupt after TLP Complete when PCIe config read operation.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us\" style=\"color: rgb(5, 99, 193); text-decoration: underline;\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MZXL512THALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL5800HBHQ-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL57T6HALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL53T2HBLS-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL5960HBHQ-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL53T8HBLS-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL56T4HALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL515THALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL51T6HBJR-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL51T9HBJR-000H3","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HP FlexFabric 10Gb 2-port 534M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C1933","Version":"7.18.82"},{"DeviceName":"HP FlexFabric 10Gb 2-port 536FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16A2103C22FA","Version":"7.18.82"},{"DeviceName":"HP FlexFabric 20Gb 2-port 630M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16A2103C1917","Version":"7.18.82"},{"DeviceName":"HPE FlexFabric 20Gb 2-port 630FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16A2103C1916","Version":"7.18.82"},{"DeviceName":"HP NPAR 10Gb 2-port 534M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C1933","Version":"7.18.82"},{"DeviceName":"HP NPAR 10Gb 2-port 536FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16A4103C22FA","Version":"7.18.82"},{"DeviceName":"HP NPAR 20Gb 2-port 630FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16A4103C1916","Version":"7.18.82"},{"DeviceName":"HP NPAR 20Gb 2-port 630M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16A4103C1917","Version":"7.18.82"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Blade QLogic NX2 Gigabit Ethernet NICs Boot code, PXE, UEFI, NCSI, iSCSI, FCoE, CCM and L2 code running under VMware vSphere 6.5, 6.7, and 7.0."},{"lang":"ja","x_late":"このパッケージには、VMware vSphere 6.5、6.7、および7.0で動作するHPE Blade QLogic NX2 Gigabit Ethernet NICブートコード、PXE、UEFI、NCSI、iSCSI、FCoE、CCMおよびL2コードをアップグレードするためのユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains combo image v7.18.82 with the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"2\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>NIC</strong></td>\n\t\t\t<td><strong>Boot Code Version</strong></td>\n\t\t\t<td><strong>PXE Version</strong></td>\n\t\t\t<td><strong>UEFI Version</strong></td>\n\t\t\t<td><strong>iSCSI Version</strong></td>\n\t\t\t<td><strong>FCoE Version</strong></td>\n\t\t\t<td><strong>CCM Version</strong></td>\n\t\t\t<td><strong>L2 Version</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HP FlexFabric 10Gb 2-port 534M Adapter<br />\n\t\t\tHP FlexFabric 10Gb 2-port 536FLB Adapter<br />\n\t\t\tHP FlexFabric 20Gb 2-port 630FLB Adapter<br />\n\t\t\tHP FlexFabric 20Gb 2-port 630M Adapter</td>\n\t\t\t<td>7.16.03</td>\n\t\t\t<td>7.14.13</td>\n\t\t\t<td>8.9.0</td>\n\t\t\t<td>7.14.0</td>\n\t\t\t<td>7.14.3</td>\n\t\t\t<td>7.14.4</td>\n\t\t\t<td>7.12.25</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"22944364","datemodified":"2021-08-11T04:12:30","file_list":["/CP047647_BUILD_8.data","/CP047647.txt","/CP047647.vmexe","/CP047647.vmexe64","/CP047647.vmfile","/CP047647_VMw.zip","/CP047647.xml","/payload.json","/CP047647_VMw.zip/index.xml","/CP047647_VMw.zip/vendor-index.xml","/CP047647_VMw.zip/metadata.zip","/CP047647_VMw.zip/vib20/CP047647/HPE_bootbank_CP047647_1.5.2.8-7.0.0.15843807.vib","/CP047647_VMw.zip/metadata.zip/vendor-index.xml","/CP047647_VMw.zip/metadata.zip/vmware.xml","/CP047647_VMw.zip/metadata.zip/vibs/CP047647-1212703154968216485.xml","/CP047647_VMw.zip/metadata.zip/bulletins/Smart-Component-CP047647_1.5.2.8-7.0.0.15843807.xml"],"md5sum":"f3a7e08b27a8a628ab3c8dcb556d4e06","name":"CP047647.zip","release":"2021-08-11T04:08:22","revision":"0","sha1sum":"6d852670363a070636bb304d540ff95ea4161559","size":"21MB","target_guids":["a6b1a447-382a-5a4f-14E4-168E103C1933","a6b1a447-382a-5a4f-14E4-16A2103C22FA","a6b1a447-382a-5a4f-14E4-16A2103C1917","a6b1a447-382a-5a4f-14E4-16A2103C1916","a6b1a447-382a-5a4f-14E4-16AE103C1933","a6b1a447-382a-5a4f-14E4-16A4103C22FA","a6b1a447-382a-5a4f-14E4-16A4103C1916","a6b1a447-382a-5a4f-14E4-16A4103C1917"],"type_of_change":"0","version":"1.5.2","vib_list":[{"name":"CP047647","version":"1.5.2.8-7.0.0.15843807"}]}],"id":{"product":"807963ddd98b4f45bbbe57b7d0cec0f8","version":"69f150005dd44d75bc753beb688e7ebb"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 7.6 version 7.14.63-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"7.6"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec63a13bba","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.14.63-1","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 7.6 version 7.14.63-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 7.7 version 7.14.63-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"7.7"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec63a13bba","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.14.63-1","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 7.7 version 7.14.63-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 8 version 7.14.63-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"8.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec63a13bba","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.14.63-1","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 8 version 7.14.63-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 12 version 7.14.63-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3da3feeb","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.14.63-1","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 12 version 7.14.63-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 12 version 7.14.63-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"12.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3da3feeb","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.14.63-1","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 12 version 7.14.63-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 15 version 7.14.63-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3da3feeb","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.14.63-1","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 15 version 7.14.63-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 15.1 version 7.14.63-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"15.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3da3feeb","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.14.63-1","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 15.1 version 7.14.63-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 1.0.87.0-1OEM.650.0.0.4598673 or greater is required and should be already active","OSVersion":{"name":"VMWare","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.87.0-1OEM.650.0.0.4598673","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 1.0.87.0-1OEM.650.0.0.4598673 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 1.0.87.0-1OEM.670.0.0.8169922 or greater is required and should be already active","OSVersion":{"name":"VMWare","value":"6.7"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.87.0-1OEM.670.0.0.8169922","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 1.0.87.0-1OEM.670.0.0.8169922 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 1.4.12.0-1OEM.700.1.0.15843807 or greater is required and should be already active","OSVersion":{"name":"VMWare","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.4.12.0-1OEM.700.1.0.15843807","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 1.4.12.0-1OEM.700.1.0.15843807 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 3.0.121.0-1OEM.700.1.0.15525992 or greater is required and should be already active","OSVersion":{"name":"VMWare","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"3.0.121.0-1OEM.700.1.0.15525992","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 3.0.121.0-1OEM.700.1.0.15525992 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Manual installation instructions:</p>\n\n<ol>\n\t<li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li>\n\t<br />\n\t<li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li>\n\t<br />\n\t<li>Unzip the CPxxxxxx.zip file.</li>\n\t<br />\n\t<li>Install the VMware component.\n\t<ol>\n\t\t<li>For ESXi 7.0 targets:&nbsp;<em>esxcli&nbsp; software component apply &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip</em>. (Example:<em> &quot;</em>esxcli software component apply &ndash;d /tmp/CPxxxxxx_VMware.zip&quot;)</li>\n\t\t<br />\n\t\t<li>For ESXi 6.x targets:&nbsp;<em>esxcli software vib install &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip</em>. (Example: &quot;esxcli software vib install &ndash;d /tmp/CPxxxxxx_VMw.zip&quot;)</li>\n\t</ol>\n\t</li>\n\t<br />\n\t<li>Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li>\n\t<br />\n\t<li>Execute the component with the command set options&nbsp; s, -f, -e, -g, &nbsp;etc. if required. When execution is complete&nbsp;the flash engine will have&nbsp;performed the flash operation as directed.</li>\n\t<br />\n\t<li>Clean up the Smart Component:\n\t<ol>\n\t\t<li>Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li>\n\t\t<br />\n\t\t<li>To clean up the Smart Component:\n\t\t<ol>\n\t\t\t<li>For ESXi 7.0 targets: <em>esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</em></li>\n\t\t\t<br />\n\t\t\t<li>For ESXi 6.x targets: <em>esxcli software vib remove &ndash;n CPxxxxxx</em></li>\n\t\t</ol>\n\t\t</li>\n\t\t<br />\n\t\t<li>Remove the directories associated with CPxxxxxx: <em>rm -rf&nbsp;/opt/Smart_Component/CPxxxxxx</em></li>\n\t</ol>\n\t</li>\n\t<br />\n\t<li>If reboot is required to complete the firmware installation, reboot your system.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p>手動によるインストール手順：</p>\n\n<ol>\n\t<li>Smartコンポーネント（CPxxxxxx.zip）をESXiホストの空き容量が十分にある場所にコピーします。（例：\"/tmp\"）</li>\n\t<br />\n\t<li>手順1でCPxxxxxx.zipファイルがコピーされた場所に移動します。</li>\n\t<br />\n\t<li>CPxxxxxx.zipファイルをunzipします。</li>\n\t<br />\n\t<li>VMwareコンポーネントをインストールします。\n\t<ol>\n\t\t<li>ESXi 7.0ターゲットの場合：<em>esxcli  software component apply –d <fully_qualified_path>/CPxxxxxx_VMw.zip</em> （例：<em></em>\"esxcli software component apply –d /tmp/CPxxxxxx_VMware.zip\"）</li>\n\t\t<br />\n\t\t<li>ESXi 6.xターゲットの場合：<em>esxcli software vib install –d <fully_qualified_path>/CPxxxxxx_VMw.zip</em> （例：\"esxcli software vib install –d /tmp/CPxxxxxx_VMw.zip\"）</li>\n\t</ol>\n\t</li>\n\t<br />\n\t<li>コンポーネントがインストールされている場所に移動します。（例：\"cd /opt/Smart_Component/CPxxxxxx\"）</li>\n\t<br />\n\t<li>必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを使用してコンポーネントを実行します。実行が完了すると、フラッシュエンジンが指示どおりにフラッシュ操作を実行します。</li>\n\t<br />\n\t<li>Smartコンポーネントをクリーンアップします。\n\t<ol>\n\t\t<li>/opt/Smart_Component/CPxxxxxから別の場所に移動します。（例：\"/tmp\"）</li>\n\t\t<br />\n\t\t<li>Smartコンポーネントをクリーンアップするには：\n\t\t<ol>\n\t\t\t<li>ESXi 7.0ターゲットの場合：<em>esxcli software component remove –n Smart-Component-CPxxxxxx</em></li>\n\t\t\t<br />\n\t\t\t<li>ESXi 6.xターゲットの場合：<em>esxcli software vib remove –n CPxxxxxx</em></li>\n\t\t</ol>\n\t\t</li>\n\t\t<br />\n\t\t<li>CPxxxxxxに関連付けられているディレクトリを削除します：<em>rm -rf /opt/Smart_Component/CPxxxxxx</em></li>\n\t</ol>\n\t</li>\n\t<br />\n\t<li>ファームウェアのインストールを完了するために再起動が必要な場合は、システムを再起動します。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade QLogic NX2 Online Firmware Upgrade Utility for VMware"},{"lang":"ja","x_late":"HPE Blade QLogic NX2オンラインファームウェアアップグレードユーティリティ for VMware"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"168E","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1933","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c22fa","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1917","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1916","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1933","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c22fa","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1916","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1917","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-03T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports VMware vSphere 7.0 U1.<br />\nThis product now supports VMware vSphere 6.7 U3.<br />\nThis product now supports VMware vSphere 6.5 U3.</p>\n","latest_fixes_x_late":"<p>This product addresses an issue where powering on the system with any I/O virtualization functionality (NPAR, SR-IOV, etc) enabled results in an Uncorrectable Machine Check Exception (UMCE).<br />\nThis product addresses an issue where the WOL option is displayed on the Human Interface Infrastructure (HII) menu for 534M and 630M mezzanine devices, even though WOL is not supported on those devices.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports VMware ESXi 7.0 U3.</p>\n","curr_fixes_x_late":"<p>This product addresses an issue where the Maximum Transmission Unit (MTU) value of iSCSI function port is displayed as 0 bytes in AHS log.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"QLOGIC_NX2_BL","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG0300FCSPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SED2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3330-304643535048","Version":"HPD2"},{"DeviceName":"EG0450FCSPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SED2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3435-30464353504b","Version":"HPD2"},{"DeviceName":"EG0600FCSPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SED2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3630-30464353504c","Version":"HPD2"},{"DeviceName":"EG0900FCSPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SED2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3930-30464353504e","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG0300FCSPH, EG0450FCSPK, EG0600FCSPL, and EG0900FCSPN"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： EG0300FCSPH、EG0450FCSPK、EG0600FCSPL、およびEG0900FCSPN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG0300FCSPH, EG0450FCSPK, EG0600FCSPL&nbsp;and EG0900FCSPN Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp; </strong>None</p>\n"}],"files":[{"bytes":"4752379","datemodified":"2021-07-23T08:32:11","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-7c1a1734f9-HPD2-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-7c1a1734f9-HPD2-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-7c1a1734f9-HPD2-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7c1a1734f9-HPD2-8.1/CP048075.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-7c1a1734f9-HPD2-8.1/TA13SED2.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-7c1a1734f9-HPD2-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7c1a1734f9-HPD2-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-7c1a1734f9-HPD2-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-7c1a1734f9-HPD2-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048075.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048075.scexe"],"md5sum":"8ee56e8118f23141e9490df5dd254291","name":"firmware-hdd-7c1a1734f9-HPD2-8.1.x86_64.rpm","release":"2021-07-23T08:18:21","revision":"0","sha1sum":"d44d6099d568b3ba6ac6e60463d0d7d8b6c80c03","size":"4MB","target_guids":["002340a5-4500-3047-3330-304643535048","002340a5-4500-3047-3435-30464353504b","002340a5-4500-3047-3630-30464353504c","002340a5-4500-3047-3930-30464353504e"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"a3c9b8269658446e8b8ae9264c4873c2","version":"455b0dea49a2414cbfb34fa2a8d8e324"},"installation":{"command":"CP040300.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EG0300FCSPH, EG0450FCSPK, EG0600FCSPL and EG0900FCSPN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64)- EG0300FCSPH、EG0450FCSPK、EG0600FCSPL、およびEG0900FCSPNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EG0300FCSPH","target_guid":"002340a5-4500-3047-3330-304643535048","type":"sas"},{"id":"EG0450FCSPK","target_guid":"002340a5-4500-3047-3435-30464353504b","type":"sas"},{"id":"EG0600FCSPL","target_guid":"002340a5-4500-3047-3630-30464353504c","type":"sas"},{"id":"EG0900FCSPN","target_guid":"002340a5-4500-3047-3930-30464353504e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-22T16:32:43","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG0450FCSPK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0300FCSPH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0900FCSPN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0600FCSPL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This component contains the driver for HPE Broadcom NetXtreme-E devices for Windows Server 2016."},{"lang":"ja","x_late":"このコンポーネントパッケージには、Windows Server 2016用 HPE Broadcom NetXtreme-Eデバイスのドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1007872","datemodified":"2021-01-14T06:58:51","file_list":["bnxtnd.cat","bnxtnd.inf","bnxtnd.sys","cp045020.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"md5sum":"6b1386867494f2a6e5a8536510a2ae76","name":"cp045020.exe","release":"2021-01-14T06:44:11","revision":"0","sha1sum":"ebe016d20f6ff0538baa6b06027699afe5d07bf8","size":"0MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec919626a4"],"type_of_change":"0","version":"218.0.32.0"}],"id":{"product":"30eade866ed942baab65d2fd9ed8adf2","version":"7256f9c1f56a4269bd6a06120f80d1c2"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the \"Install\" button to proceed with the installation."},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>［インストール］ボタンをクリックして、インストールを開始します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Windows Server 2016 的 HPE Broadcom NetXtreme-E 驅動程式"},{"lang":"en","x_late":"HPE Broadcom NetXtreme-E Driver for Windows Server 2016"},{"lang":"ko","x_late":"Windows Server 2016용 HPE Broadcom NetXtreme-E 드라이버"},{"lang":"cn","x_late":"Windows Server 2016版HPE Broadcom NetXtreme-E驱动程序"},{"lang":"ja","x_late":"HPE Broadcom NetXtreme-E ドライバー for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"600"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This product correct an issue which live firmware upgrade fails when run on both interfaces of the adapter simultaneously.</li>\n\t<li>This product corrects a timeout issue which configures network connection.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product correct an Wake-on-LAN (WoL) function unavailable.</li>\n\t<li>This product correct an issue which fixes VF will not load on certain Virtual OS when Windows is host OS.&nbsp;</li>\n\t<li>This product correct an issue which fixes user mode RDMA blue screen of death (BSoD) caused by an IRP SystemBuffer access race condition</li>\n\t<li>This product corrects a Windows Stop Error blue screen of death (BSoD) seen when uninstalling the NDIS driver.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"bnxtnd.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWWQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNETG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757575155","Version":"HPG2"},{"DeviceName":"MB006000GWWQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNETG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304757575154","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB008000GWWQU and MB006000GWWQT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB008000GWWQU and MB006000GWWQT Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"17721440","datemodified":"2021-08-27T11:36:40","file_list":["/CP048425_BUILD_2.data","/CP048425.vmexe","/CP048425.vmexe64","/CP048425.vmfile","/CP048425_VMw.zip","/CP048425.xml","/payload.json","/CP048425_VMw.zip/index.xml","/CP048425_VMw.zip/vendor-index.xml","/CP048425_VMw.zip/metadata.zip","/CP048425_VMw.zip/vib20/CP048425/HPE_bootbank_CP048425_HPG2.2-7.0.0.15843807.vib","/CP048425_VMw.zip/metadata.zip/vendor-index.xml","/CP048425_VMw.zip/metadata.zip/vmware.xml","/CP048425_VMw.zip/metadata.zip/vibs/CP048425--1460648084595783290.xml","/CP048425_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048425_HPG2.2-7.0.0.15843807.xml"],"md5sum":"2ec8694949f8fc94a06dad74805d33b5","name":"CP048425.zip","release":"2021-08-27T11:31:31","revision":"0","sha1sum":"9739f463ff88f79a6e685c6cb4ae52440e067716","size":"16MB","target_guids":["4d2340a5-3042-3830-3030-304757575155","4d2340a5-3042-3630-3030-304757575154"],"type_of_change":"1","version":"HPG2","vib_list":[{"name":"CP048425","version":"HPG2.2-7.0.0.15843807"}]}],"id":{"product":"fbe68804b30c4fe28e13ea472cae5392","version":"cbd2d9f88684491a891cd46743d69688"},"installation":{"command":"CP043253.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB008000GWWQU and MB006000GWWQT Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor ESXi - MB008000GWWQUおよびMB006000GWWQTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB008000GWWQU","target_guid":"4d2340a5-3042-3830-3030-304757575155","type":"sata"},{"id":"MB006000GWWQT","target_guid":"4d2340a5-3042-3630-3030-304757575154","type":"sata"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-10T06:00:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000GWWQT","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB008000GWWQU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000300JWFVB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SErD3.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57465642","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: EG000300JWFVB"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EG000300JWFVB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG000300JWFVB Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"16252392","datemodified":"2021-08-27T09:54:59","file_list":["/CP048245_BUILD_2.data","/CP048245.vmexe","/CP048245.vmexe64","/CP048245.vmfile","/CP048245_VMw.zip","/CP048245.xml","/payload.json","/CP048245_VMw.zip/index.xml","/CP048245_VMw.zip/vendor-index.xml","/CP048245_VMw.zip/metadata.zip","/CP048245_VMw.zip/vib20/CP048245/HPE_bootbank_CP048245_HPD3.2-7.0.0.15843807.vib","/CP048245_VMw.zip/metadata.zip/vendor-index.xml","/CP048245_VMw.zip/metadata.zip/vmware.xml","/CP048245_VMw.zip/metadata.zip/vibs/CP048245-2464200756205669878.xml","/CP048245_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048245_HPD3.2-7.0.0.15843807.xml"],"md5sum":"b87c13cd2045da4702e0e9fdd45e78da","name":"CP048245.zip","release":"2021-08-27T09:49:15","revision":"0","sha1sum":"65a2a4b2f4e346460abe3ea3efd53ad1f04c7704","size":"15MB","target_guids":["452340a5-3047-3030-3330-304a57465642"],"type_of_change":"1","version":"HPD3","vib_list":[{"name":"CP048245","version":"HPD3.2-7.0.0.15843807"}]}],"id":{"product":"911c76d50a064e62be53550825c8db4d","version":"92aab0359c734a0aba2419175bfd1901"},"installation":{"command":"CP040631.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - EG000300JWFVB Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EG000300JWFVBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG000300JWFVB","target_guid":"452340a5-3047-3030-3330-304a57465642","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-01T12:29:35","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>A low-probability, high severity corner case of sustained outer-diameter activity with emergency power off when heads are at the outer diameter prevented heads from parking/latching properly on a few drives in the field.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG000300JWFVB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000JVYZD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPESD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a56595a44","Version":"HPD4"},{"DeviceName":"MB4000JVYZC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPESD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a56595a43","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB6000JVYZD and MB4000JVYZC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB6000JVYZD and MB4000JVYZC Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:&nbsp;</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"17596609","datemodified":"2021-08-27T04:38:42","file_list":["/CP048380_BUILD_2.data","/CP048380.vmexe","/CP048380.vmexe64","/CP048380.vmfile","/CP048380_VMw.zip","/CP048380.xml","/payload.json","/CP048380_VMw.zip/index.xml","/CP048380_VMw.zip/vendor-index.xml","/CP048380_VMw.zip/metadata.zip","/CP048380_VMw.zip/vib20/CP048380/HPE_bootbank_CP048380_HPD4.2-7.0.0.15843807.vib","/CP048380_VMw.zip/metadata.zip/vendor-index.xml","/CP048380_VMw.zip/metadata.zip/vmware.xml","/CP048380_VMw.zip/metadata.zip/vibs/CP048380--6716017894554559665.xml","/CP048380_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048380_HPD4.2-7.0.0.15843807.xml"],"md5sum":"4972af028762549b3e8f9992e387280d","name":"CP048380.zip","release":"2021-08-27T04:33:49","revision":"0","sha1sum":"aca3c37f9efc5f175956348531b6fb657ffc1217","size":"16MB","target_guids":["002340a5-4d00-3642-3030-304a56595a44","002340a5-4d00-3442-3030-304a56595a43"],"type_of_change":"1","version":"HPD4","vib_list":[{"name":"CP048380","version":"HPD4.2-7.0.0.15843807"}]}],"id":{"product":"d9159bc289514e83950fce1ae62143a1","version":"f4732a1b1b4947c1a8986c26e3763811"},"installation":{"command":"CP040636.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>Additional information to execute VIB file.</strong></p>\n\n<p><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p>             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul>\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p> </p>\n\n<p><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul>\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul>\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - MB6000JVYZD and MB4000JVYZC Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB4000JVYZC","target_guid":"002340a5-4d00-3442-3030-304a56595a43","type":"sas"},{"id":"MB6000JVYZD","target_guid":"002340a5-4d00-3642-3030-304a56595a44","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T08:27:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JVYZC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB6000JVYZD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter and mezzanine host bus adapters. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"5768745","datemodified":"2021-08-27T03:30:52","file_list":["./etc/depmod.d/qla2xxx.conf","./etc/udev/rules.d/99-nvme-fc.rules","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/qlgc-qla2xxx","./lib/modules/3.10.0-1160.el7.x86_64/extra/qlgc-qla2xxx/qla2xxx.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/qlgc-qla2xxx/tcm_qla2xxx.ko","./usr/lib/dracut/dracut.conf.d/70-qla2xxx-nvmefc-autoconnect.conf","./usr/lib/systemd/system/qla2xxx-nvmefc-boot-connection.service","./usr/lib/systemd/system/qla2xxx-nvmefc-connect@.service","./usr/lib/udev/rules.d/70-qla2xxx-nvmefc-autoconnect.rules","./usr/sbin/qla2xxx/qla2xxx_nvme_boot_connections.sh","./usr/share/smartupdate/kmod-qlgc-qla2xxx/component.xml"],"md5sum":"bb542a62c0c34b5dbf54c934b9ec536b","name":"kmod-qlgc-qla2xxx-10.02.01.00.a14_k1-1.rhel7u9.x86_64.rpm","release":"2021-08-27T03:21:31","revision":"0","sha1sum":"6e95609121a5ce402c6cb9fdc7196e2c2cea0b3c","size":"5MB","target_guids":[],"type_of_change":"1","version":"10.02.01.00.a14-k1"}],"id":{"product":"43c6015819ee4fee96f47500fb1e7d62","version":"304cd78a7ee34f259cd64c514809f0f8"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-qla2xxx-4.6.28-20.rhel6u1.x86_64.rpm<br />\n<br />\n4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;&nbsp;</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Red Hat Enterprise Linux 7 Update 9 Server Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters and Mezzanine Host Bus Adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015D","subven":"1077","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015C","subven":"1077","target_guid":"","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-18T06:47:23","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to driver version 10.02.01.00.a14-k1</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"kmod-qlgc-qla2xxx","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800026","languages":[{"lang":"tw","x_late":"軟體 - 管理"},{"lang":"en","x_late":"Software - Management"},{"lang":"ko","x_late":"소프트웨어 - 관리"},{"lang":"ja","x_late":"ソフトウェア - マネジメント"},{"lang":"cn","x_late":"软件 - 管理"}]}],"description":[{"lang":"en","x_late":"The HPE Fiber Channel and Storage Enablement Bundle Smart Component for ESXi 7.0 includes the latest Fiber Channel and Storage libraries."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6656340","datemodified":"2021-09-01T01:47:12","file_list":["/cp047521.xml","/fc-enablement-component_700.3.8.0.6-1_18506758.zip","/fc-enablement-component_700.3.8.0.6-1_18506758.zip/index.xml","/fc-enablement-component_700.3.8.0.6-1_18506758.zip/vendor-index.xml","/fc-enablement-component_700.3.8.0.6-1_18506758.zip/metadata.zip","/fc-enablement-component_700.3.8.0.6-1_18506758.zip/vib20/fc-enablement/HPE_bootbank_fc-enablement_700.3.8.0.6-1OEM.700.1.0.15843807.vib","/fc-enablement-component_700.3.8.0.6-1_18506758.zip/metadata.zip/vendor-index.xml","/fc-enablement-component_700.3.8.0.6-1_18506758.zip/metadata.zip/vmware.xml","/fc-enablement-component_700.3.8.0.6-1_18506758.zip/metadata.zip/vibs/fc-enablement-1807629225033749204.xml","/fc-enablement-component_700.3.8.0.6-1_18506758.zip/metadata.zip/bulletins/fc-enablement-component_700.3.8.0.6-1.xml"],"md5sum":"d11a0e12a83f2b1ef7273959ad4547c3","name":"cp047521.zip","release":"2021-09-01T01:44:06","revision":"0","sha1sum":"b894bd6cab9c222556de5c1bfb96ca3f27a5f7c8","size":"6MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecbf0a9496","20a6e8e4-bf33-4c71-a6bf-d9ecb46a2f45"],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"fc-enablement","version":"700.3.8.0.6-1OEM.700.1.0.15843807"}]}],"id":{"product":"f97eb4848b18499fa1a1379ab7b46d05","version":"fd31e0e175e9400a92d284cae64a1c46"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To&nbsp;remotely install&nbsp;this&nbsp;bundle&nbsp; online using the HP Smart Update Manager (HPSUM) from the HP Service Pack for ProLiant (SPP):</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\">HPE USB Key Utility</a>.</li>\n\t<li>Copy&nbsp;this driver component&nbsp;to the directory<em> /SPP20xxxxx/hp/swpackages</em> on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.</li>\n\t<li>Change directories to <em>/hp/swpackages</em> and execute&nbsp;./hpsum.</li>\n\t<li>Select the &quot;next&quot; button.</li>\n\t<li>Click &quot;Add Single Target.&quot;</li>\n\t<li>Enter&nbsp;the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow HP Smart Update Manager&nbsp;instructions&nbsp;to complete the driver update.</li>\n</ol>\n\n<p><br />\n<strong>To&nbsp;install this bundle using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the component zip file to extract the driver offline bundle.</li>\n\t<li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li>\n</ol>\n\n<p>Refer to VMware documentation for information on the esxcli commands</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Fiber Channel and Storage Enablement Bundle Smart Component for ESXi 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"7500"},"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-05T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Supports VMware ESXi 7.0 and ESXi 7.0 U1</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Supports VMware ESXi 7.0 U2 and ESXi 7.0 U3</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"fc-enablement-component:700.3.8.0.6-1","sw_key_expectedpath":"software.component:vmware:zip"},{"name":"fc-enablement:700.3.8.0.6-1OEM.700.1.0.15843807","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6169884","datemodified":"2021-06-01T21:01:07","file_list":["/CP047379.vmexe","/CP047379.vmfile","/CP047379.xml","/README.txt"],"md5sum":"9a47b5b793b9843a06dfd1b7b7d48a9b","name":"CP047379.zip","release":"2021-06-02T01:58:04","revision":"0","sha1sum":"e8457b6fad0c40e29aeb67381203686d947dd311","size":"5MB","target_guids":[],"type_of_change":"1","version":"3.00_04-01-2021","vib_list":[]}],"id":{"product":"0f73895a23994ef3b308a27affe1d7ce","version":"5ceb5b4c613b4adfad7190c0b14e6314"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component requires that the CRU driver be loaded before the component can run.<br />\nThe minimum CRU version for 5.5 is 5.5.4.1.<br />\nThe minimum CRU version for 6.0 is 6.0.8.<br />\nThe minimum CRU version for 6.5 is 6.5.8.</p>\n\n<p>The minimum CRU version for 6.7 is 6.7.10.<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>SPP Offline mode boots a special Linux OS environment, thus the Linux Components are used, not the VMware Components</li>\n</ul>\n\n<p><br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Download the appropriate SPP</li>\n\t<li>Add the component to the SPP</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run SUM</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps to complete the firmware update</li>\n\t<li>Refer to the SPP documentation for detailed instructions at:&nbsp; <a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Component ( CPxxxxxx.zip) in a temporary directory</li>\n\t<li>From the same directory, unzip the Component:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>To perform the standalone installation, execute the command:<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>Follow the directions given by the Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system for the firmware update to take effect</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、実行する前にCRUドライバーがロードされている必要があります。<br />\n5.5の最小CRUバージョンは5.5.4.1です。<br />\n6.0の最小CRUバージョンは6.0.8です。<br />\n6.5の最小CRUバージョンは6.5.8です。</p>\n\n<p>6.7の最小CRUバージョンは6.7.10です。<br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMwareコンポーネントではなく、Linuxコンポーネントが用いられます</li>\n</ul>\n\n<p><br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします</li>\n\t<li>SPPにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします</li>\n\t<li>SUMを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います</li>\n\t<li>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>コンポーネント (CPxxxxxx.zip)を一時ディレクトリに置きます</li>\n\t<li>同じディレクトリからコンポーネントをunzipします:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>スタンドアロンのインストールを行うために、次のコマンドを実行します：<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>コンポーネントの指示に従います</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n\t<li>システムを再起動し、ファームウェアのアップデートを有効にします</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware - HPE ProLiant ML30 Gen9 (U23) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor VMware - HPE ProLiant ML30 Gen9 (U23)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"5","minor":"5","name":"VMware vSphere 5.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-26T07:15:16","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode: 0x000000E2 (CPUID 506E3). This Intel microcode patch provide mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-8696 and CVE-2020-8698. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00381. These issues are not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-24512. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-464. The Intel microcode patches included in this release are version 0x000000EA (CPUID 506E3 and CPUID 906E9). These issues are not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel sighting CVE-2020-24512. This security vulnerability is documented in Intel Security Advisory INTEL-SA-00463. The Intel microcode patches included in this release are version 0x000000EA (CPUID 506E3) and 0x000000EA (CPUID 906E9). This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-8670 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"}],"sw_keys":[{"name":"U23","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK003840GWHTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M51004G8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-304757485445","Version":"HPG8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MK003840GWHTE Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MK003840GWHTEドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux&nbsp;(x64)&nbsp;-&nbsp;MK003840GWHTE Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG6<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG6</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4969038","datemodified":"2021-07-23T07:44:04","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-ac20a1e1c6-HPG8-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac20a1e1c6-HPG8-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac20a1e1c6-HPG8-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac20a1e1c6-HPG8-2.1/CP048177.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac20a1e1c6-HPG8-2.1/M51004G8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac20a1e1c6-HPG8-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac20a1e1c6-HPG8-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac20a1e1c6-HPG8-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac20a1e1c6-HPG8-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048177.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048177.scexe"],"md5sum":"527c4bd24316a558ffe687a0ab41648f","name":"firmware-hdd-ac20a1e1c6-HPG8-2.1.x86_64.rpm","release":"2021-07-23T07:30:17","revision":"0","sha1sum":"287e1eb6dcde198a218364919dd90efc1c4fb8f0","size":"4MB","target_guids":["4d2340a5-304b-3330-3834-304757485445"],"type_of_change":"1","version":"HPG8"}],"id":{"product":"e0a6e611d1444b4f8561da2a0566c408","version":"0d5d4f33e7dc4e21ad1a60e468344f16"},"installation":{"command":"CP041322.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/jp/servers/spp_dl\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MK003840GWHTE Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MK003840GWHTEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T20:16:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Improvements to Product Quality and Reliability.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK003840GWHTE","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"XP0120GFJSL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"ASAXHPS4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5800-3050-3132-3047464a534c","Version":"HPS4"},{"DeviceName":"XP0240GFJSN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"ASAXHPS4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5800-3050-3234-3047464a534e","Version":"HPS4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: XP0120GFJSL and XP0240GFJSN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - &nbsp;XP0120GFJSL and XP0240GFJSN Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPS4<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"17353483","datemodified":"2021-08-27T11:15:02","file_list":["/CP048423_BUILD_4.data","/CP048423.vmexe","/CP048423.vmexe64","/CP048423.vmfile","/CP048423_VMw.zip","/CP048423.xml","/payload.json","/CP048423_VMw.zip/index.xml","/CP048423_VMw.zip/vendor-index.xml","/CP048423_VMw.zip/metadata.zip","/CP048423_VMw.zip/vib20/CP048423/HPE_bootbank_CP048423_HPS4.4-7.0.0.15843807.vib","/CP048423_VMw.zip/metadata.zip/vendor-index.xml","/CP048423_VMw.zip/metadata.zip/vmware.xml","/CP048423_VMw.zip/metadata.zip/vibs/CP048423-3173615281499992228.xml","/CP048423_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048423_HPS4.4-7.0.0.15843807.xml"],"md5sum":"887d3fee42457d4341e29d1ec1ad1767","name":"CP048423.zip","release":"2021-08-27T11:09:32","revision":"0","sha1sum":"4aba33879f495a7920abf599a8fd9793ce252869","size":"16MB","target_guids":["002340a5-5800-3050-3132-3047464a534c","002340a5-5800-3050-3234-3047464a534e"],"type_of_change":"1","version":"HPS4","vib_list":[{"name":"CP048423","version":"HPS4.4-7.0.0.15843807"}]}],"id":{"product":"71f736a9e5684fd69f80904bf78b29e9","version":"fce7208e949d4e3ab9b4dfec39fa7d95"},"installation":{"command":"CP040520.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - XP0120GFJSL and XP0240GFJSN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - XP0120GFJSLおよびXP0240GFJSNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"XP0120GFJSL","target_guid":"002340a5-5800-3050-3132-3047464a534c","type":"sata"},{"id":"XP0240GFJSN","target_guid":"002340a5-5800-3050-3234-3047464a534e","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-10T02:45:54","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"XP0120GFJSL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"XP0240GFJSN","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"VMware vSphere 6.7 Fibre Channel Driver kit for HPE Storage Emulex Host Bus Adapters(HBAs)"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"735100","datemodified":"2021-08-26T11:39:56","file_list":["/Broadcom-ELX-lpfc_12.8.528.14-1OEM.670.0.0.8169922-offline_bundle-18484921.zip","/cp048604.xml","/Broadcom-ELX-lpfc_12.8.528.14-1OEM.670.0.0.8169922-offline_bundle-18484921.zip/index.xml","/Broadcom-ELX-lpfc_12.8.528.14-1OEM.670.0.0.8169922-offline_bundle-18484921.zip/vendor-index.xml","/Broadcom-ELX-lpfc_12.8.528.14-1OEM.670.0.0.8169922-offline_bundle-18484921.zip/metadata.zip","/Broadcom-ELX-lpfc_12.8.528.14-1OEM.670.0.0.8169922-offline_bundle-18484921.zip/vib20/lpfc/EMU_bootbank_lpfc_12.8.528.14-1OEM.670.0.0.8169922.vib","/Broadcom-ELX-lpfc_12.8.528.14-1OEM.670.0.0.8169922-offline_bundle-18484921.zip/metadata.zip/vendor-index.xml","/Broadcom-ELX-lpfc_12.8.528.14-1OEM.670.0.0.8169922-offline_bundle-18484921.zip/metadata.zip/vmware.xml","/Broadcom-ELX-lpfc_12.8.528.14-1OEM.670.0.0.8169922-offline_bundle-18484921.zip/metadata.zip/vibs/lpfc--6885805289219874139.xml","/Broadcom-ELX-lpfc_12.8.528.14-1OEM.670.0.0.8169922-offline_bundle-18484921.zip/metadata.zip/bulletins/Broadcom-ELX-lpfc_12.8.528.14-1OEM.670.0.0.8169922.xml"],"md5sum":"7a22281f7927677b4705e7b87fac640f","name":"cp048604.zip","release":"2021-08-26T11:39:13","revision":"0","sha1sum":"3160438afea4c5fb7c7f727abb878409022519b2","size":"717KB","target_guids":[],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"lpfc","version":"12.8.528.14-1OEM.670.0.0.8169922"}]}],"id":{"product":"f103143bf44343e98019428dc533df7d","version":"acdd673f23c0481fbcfb8d440978eb43"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the&nbsp;driver update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware Vsphere Update Manager(VUM) or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on Vsphere Update Manager(VUM) and the esxcli commands</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Emulex Fibre Channel driver component for VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"F100","subven":"10DF","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T10:36:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to Driver version 12.8.528.14</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"lpfc:12.8.528.14-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXL5800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3830-3048d90154e8","Version":"MPK75H5Q"},{"DeviceName":"MZXL51T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3154-36487a9b1618","Version":"MPK75H5Q"},{"DeviceName":"MZXL53T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3354-324884d9e9f5","Version":"MPK75H5Q"},{"DeviceName":"MZXL56T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3654-34482ab7fb8f","Version":"MPK75H5Q"},{"DeviceName":"MZXL512THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3132-544895b51a17","Version":"MPK75H5Q"},{"DeviceName":"MZXL5960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3936-304894dc03d2","Version":"MPK75H5Q"},{"DeviceName":"MZXL51T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3154-3948e450274f","Version":"MPK75H5Q"},{"DeviceName":"MZXL53T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3354-38483310a47b","Version":"MPK75H5Q"},{"DeviceName":"MZXL57T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3754-364820f1a5c1","Version":"MPK75H5Q"},{"DeviceName":"MZXL515THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3135-54486d0092b3","Version":"MPK75H5Q"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-000H3"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Linux (x64) - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-000H3&nbsp; Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>MPK75H5Q</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; MPK73H5Q</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; MPK73H5Q</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problem Fixed:</strong></p>\n\n<ul>\n\t<li>Fixed False UECC issue at idle power mode (12.8TB and 15.36TB only).</li>\n\t<li>Apply PCLK running PHY option, PLL clock disable can be avoided in lane 0 missing case.</li>\n\t<li>Old FW download Blocking.</li>\n\t<li>FW is changed off the option of TX data alignment for each lane.</li>\n\t<li>FW is changed to clear the interrupt after TLP Complete when PCIe config read operation.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us\" style=\"color: rgb(5, 99, 193); text-decoration: underline;\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong></p>\n\n<p><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>\n"}],"files":[{"bytes":"9547371","datemodified":"2021-07-25T12:34:35","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK75H5Q-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK75H5Q-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK75H5Q-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK75H5Q-3.1/CP048227.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK75H5Q-3.1/MPK75H5Q.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK75H5Q-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK75H5Q-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK75H5Q-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK75H5Q-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048227.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048227.scexe"],"md5sum":"9019f67244fafea82b44d6304ab3e693","name":"firmware-hdd-e320db791d-MPK75H5Q-3.1.x86_64.rpm","release":"2021-07-25T12:21:04","revision":"0","sha1sum":"ad3cba47d3192a012d01bb1e0ce395382a811d47","size":"9MB","target_guids":["4d2340a5-585a-354c-3830-3048d90154e8","4d2340a5-585a-354c-3154-36487a9b1618","4d2340a5-585a-354c-3354-324884d9e9f5","4d2340a5-585a-354c-3654-34482ab7fb8f","4d2340a5-585a-354c-3132-544895b51a17","4d2340a5-585a-354c-3936-304894dc03d2","4d2340a5-585a-354c-3154-3948e450274f","4d2340a5-585a-354c-3354-38483310a47b","4d2340a5-585a-354c-3754-364820f1a5c1","4d2340a5-585a-354c-3135-54486d0092b3"],"type_of_change":"2","version":"MPK75H5Q"}],"id":{"product":"5b139cd72d0b4c89818f276c3a1dce8c","version":"d6f696e709a84b54827dfa7a6c509c13"},"installation":{"command":"CP043037.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p><strong>Additional Information:</strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p><strong>追加情報:</strong></p>\n\n<p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-00H3 Drive"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - MZXL5800HBHQ-000H3、 MZXL51T6HBJR-000H3、MZXL53T2HBLS-000H3、MZXL56T4HALA-000H3、MZXL512THALA-000H3、 MZXL5960HBHQ-000H3、MZXL51T9HBJR-000H3、MZXL53T8HBLS-000H3、MZXL57T6HALA-000H3および MZXL515THALA-00H3ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MZXL515THALA-000H3","target_guid":"4d2340a5-585a-354c-3135-54486d0092b3","type":"nvme"},{"id":"MZXL512THALA-000H3","target_guid":"4d2340a5-585a-354c-3132-544895b51a17","type":"nvme"},{"id":"MZXL57T6HALA-000H3","target_guid":"4d2340a5-585a-354c-3754-364820f1a5c1","type":"nvme"},{"id":"MZXL56T4HALA-000H3","target_guid":"4d2340a5-585a-354c-3654-34482ab7fb8f","type":"nvme"},{"id":"MZXL53T8HBLS-000H3","target_guid":"4d2340a5-585a-354c-3354-38483310a47b","type":"nvme"},{"id":"MZXL53T2HBLS-000H3","target_guid":"4d2340a5-585a-354c-3354-324884d9e9f5","type":"nvme"},{"id":"MZXL51T9HBJR-000H3","target_guid":"4d2340a5-585a-354c-3154-3948e450274f","type":"nvme"},{"id":"MZXL51T6HBJR-000H3","target_guid":"4d2340a5-585a-354c-3154-36487a9b1618","type":"nvme"},{"id":"MZXL5960HBHQ-000H3","target_guid":"4d2340a5-585a-354c-3936-304894dc03d2","type":"nvme"},{"id":"MZXL5800HBHQ-000H3","target_guid":"4d2340a5-585a-354c-3830-3048d90154e8","type":"nvme"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-01T04:31:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>\n\t<p>Added support for VMD enabled Intel VROC platform</p>\n\t</li>\n</ul>\n","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Fixed False UECC issue at idle power mode (12.8TB and 15.36TB only).</li>\n\t<li>Apply PCLK running PHY option, PLL clock disable can be avoided in lane 0 missing case.</li>\n\t<li>Old FW download Blocking.</li>\n\t<li>FW is changed off the option of TX data alignment for each lane.</li>\n\t<li>FW is changed to clear the interrupt after TLP Complete when PCIe config read operation.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us\" style=\"color: rgb(5, 99, 193); text-decoration: underline;\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us</a></li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Fixed False UECC issue at idle power mode (12.8TB and 15.36TB only).</li>\n\t<li>Apply PCLK running PHY option, PLL clock disable can be avoided in lane 0 missing case.</li>\n\t<li>Old FW download Blocking.</li>\n\t<li>FW is changed off the option of TX data alignment for each lane.</li>\n\t<li>FW is changed to clear the interrupt after TLP Complete when PCIe config read operation.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MZXL512THALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL5800HBHQ-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL57T6HALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL53T2HBLS-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL5960HBHQ-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL53T8HBLS-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL56T4HALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL515THALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL51T6HBJR-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL51T9HBJR-000H3","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"本產品包含 Red Hat Enterprise Linux 7 x86_64 下執行的 HPE Intel Gigabit 乙太網路 NIC 驅動程式。"},{"lang":"en","x_late":"This product contains the drivers for HPE Intel Gigabit Ethernet NICs running under Red Hat Enterprise Linux 7 x86_64."},{"lang":"ko","x_late":"이 제품에는 Red Hat Enterprise Linux 7 x86_64에서 실행되는 HPE Intel 기가비트 이더넷 NIC용 드라이버가 포함되어 있습니다."},{"lang":"cn","x_late":"本产品包含适用于在 Red Hat Enterprise Linux 7 x86_64 下方运行的 HPE Intel 千兆以太网网卡驱动程序。"},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7 x86_64で動作するHPE Intel Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"128720","datemodified":"2021-08-24T16:25:09","file_list":["./etc/depmod.d/hp-igb.conf","./etc/dracut.conf.d/hp-igb-oob.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/hp-igb","./lib/modules/3.10.0-1160.el7.x86_64/extra/hp-igb/igb.ko","./usr/lib/.build-id","./usr/lib/.build-id/67","./usr/lib/.build-id/67/198f10e4d0ed653c118ccc8633c76491f4ddd2","./usr/share/smartupdate/kmod-hp-igb/component.xml"],"md5sum":"daaacf030cf6bb95b155a73020531e6b","name":"kmod-hp-igb-6.7.2-2.rhel7u9.x86_64.rpm","release":"2021-08-24T16:11:05","revision":"0","sha1sum":"b04cd64b1eada06d0fac1e70c85fdce56ac2838f","size":"125KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf5d54211"],"type_of_change":"0","version":"6.7.2-2"},{"bytes":"128717","datemodified":"2021-08-24T16:24:01","file_list":["./etc/depmod.d/hp-igb.conf","./etc/dracut.conf.d/hp-igb-oob.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/hp-igb","./lib/modules/3.10.0-1127.el7.x86_64/extra/hp-igb/igb.ko","./usr/lib/.build-id","./usr/lib/.build-id/a9","./usr/lib/.build-id/a9/c46fbfb3c1c62ecaad5d60244974fa5a73eb2c","./usr/share/smartupdate/kmod-hp-igb/component.xml"],"md5sum":"d7944a8e7b07a6ef60c93cf6466fcabf","name":"kmod-hp-igb-6.7.2-2.rhel7u8.x86_64.rpm","release":"2021-08-24T16:11:05","revision":"0","sha1sum":"0769a87062825c6971544459b0c9e16a91da653c","size":"125KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf5d54211"],"type_of_change":"0","version":"6.7.2-2"}],"id":{"product":"8641d1fe608b4b84a83d535f2b785a88","version":"082088f1c7494c65a69021bd880b3823"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"},{"lang":"ja","x_late":"<p>インストールのノートについてREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 Red Hat Enterprise Linux 7 x86_64 的 HPE Intel igb 驅動程式"},{"lang":"en","x_late":"HPE Intel igb Drivers for Red Hat Enterprise Linux 7 x86_64"},{"lang":"ko","x_late":"Red Hat Enterprise Linux 7 x86_64용 HPE Intel igb 드라이버"},{"lang":"cn","x_late":"适用于 Red Hat Enterprise Linux 7 x86_64 的 HPE Intel igb 驱动程序"},{"lang":"ja","x_late":"HPE Intel igbドライバー for Red Hat Enterprise Linux 7 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1523","subdev":"1989","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1523103c1989","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00FF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1521159000ff","type":"pci","ven":"8086"},{"dev":"1521","subdev":"337F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c337f","type":"pci","ven":"8086"},{"dev":"1521","subdev":"339E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c339e","type":"pci","ven":"8086"},{"dev":"1521","subdev":"17D1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c17d1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"3380","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-1521103c3380","type":"pci","ven":"8086"},{"dev":"1521","subdev":"8157","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c8157","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00A3","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a3","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product is particular for&nbsp;Red Hat Enterprise Linux 7 Update 8 patched kernel version 3.10.0-1127.10.1 or later.</p>\n","latest_fixes_x_late":"<p>This product corrects an issue where the patched kernel symbol changed on PTP (Precision Time Protocol) module.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports Linux Firmware upgrade utility v.1.22.5</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"kmod-hp-igb","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-igb","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-igb","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-igb","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO0400KEFHN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3430-304b4546484e","Version":"HPK4"},{"DeviceName":"MO0800KEFHP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3830-304b45464850","Version":"HPK4"},{"DeviceName":"MO1600KEFHQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304b45464851","Version":"HPK4"},{"DeviceName":"MO2000KEFHR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-324f-3030-304b45464852","Version":"HPK4"},{"DeviceName":"MT0800KEXUU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3054-3830-304b45585555","Version":"HPK4"},{"DeviceName":"MT1600KEXUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3154-3630-304b45585556","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MO0400KEFHN, MO0800KEFHP, MO1600KEFHQ, MO2000KEFHR, MT0800KEXUU and MT1600KEXUV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;NVMe SSD&nbsp;Flash Component for Linux (x64) - MO0400KEFHN, MO0800KEFHP, MO1600KEFHQ, MO2000KEFHR, MT0800KEXUU&nbsp;and MT1600KEXUV Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4758666","datemodified":"2021-07-25T13:00:12","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-2a5b65f157-HPK4-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-2a5b65f157-HPK4-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-2a5b65f157-HPK4-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2a5b65f157-HPK4-6.1/4IFDHPK4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-2a5b65f157-HPK4-6.1/CP045365.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-2a5b65f157-HPK4-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2a5b65f157-HPK4-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-2a5b65f157-HPK4-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-2a5b65f157-HPK4-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045365.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045365.scexe"],"md5sum":"d7a272a1d68058b4d8a1557706056122","name":"firmware-hdd-2a5b65f157-HPK4-6.1.x86_64.rpm","release":"2021-07-25T12:34:04","revision":"0","sha1sum":"d90e42b8ed3b3261c604efe4d239b79dcaebd6b5","size":"4MB","target_guids":["002340a5-4d00-304f-3430-304b4546484e","002340a5-4d00-304f-3830-304b45464850","002340a5-4d00-314f-3630-304b45464851","002340a5-4d00-324f-3030-304b45464852","002340a5-4d00-3054-3830-304b45585555","002340a5-4d00-3154-3630-304b45585556"],"type_of_change":"1","version":"HPK4"}],"id":{"product":"74b89b05406c4068843f3b27148a33d9","version":"65335ea2137647a1bb692bd75cc0b0bc"},"installation":{"command":"CP040087.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64)  - MO0400KEFHN, MO0800KEFHP, MO1600KEFHQ, MO2000KEFHR, MT0800KEXUU and MT1600KEXUV Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux（x64）- MO0400KEFHN、MO0800KEFHP、MO1600KEFHQ、MO2000KEFHR、MT0800KEXUU、およびMT1600KEXUVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MT0800KEXUU","target_guid":"002340a5-4d00-3054-3830-304b45585555","type":"nvme"},{"id":"MT1600KEXUV","target_guid":"002340a5-4d00-3154-3630-304b45585556","type":"nvme"},{"id":"MO0400KEFHN","target_guid":"002340a5-4d00-304f-3430-304b4546484e","type":"nvme"},{"id":"MO0800KEFHP","target_guid":"002340a5-4d00-304f-3830-304b45464850","type":"nvme"},{"id":"MO1600KEFHQ","target_guid":"002340a5-4d00-314f-3630-304b45464851","type":"nvme"},{"id":"MO2000KEFHR","target_guid":"002340a5-4d00-324f-3030-304b45464852","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T11:13:10","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MT0800KEXUU","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT1600KEXUV","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO0400KEFHN","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO2000KEFHR","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO1600KEFHQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO0800KEFHP","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]}],"documentation":[],"files":[{"bytes":"5587432","datemodified":"2019-08-07T16:11:58","file_list":["SignedImageInstaller64.dll","U26_2.66_07_19_2019.signed.flash","cp040771.xml","cpqsetup.exe","cpqsysio64.sys"],"md5sum":"d913b1a150c39dcfe5a977dbe7ed0cd3","name":"cp040771.exe","release":"2019-08-07T15:56:02","revision":"0","sha1sum":"21fc8d9029a886068ec059802f068ab81892dea1","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.66_07-19-2019"}],"id":{"product":"dd9af2922ef944c1aae83a2243605be9","version":"a94d8cbb2ab44854b1ac6b49efda50cb"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant EC200a (U26) Server/HPE ProLiant Thin Micro TM200 (U26) Server"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-08-24T22:56:03","revision_history":[{"lang":"en","latest_enhancements_x_late":null,"latest_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>Updated the Intel processor microcode to the latest version.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"<p>None</p>\n","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigation for an Intel sighting where the system may experience a machine check after updating to the latest System ROM which contained a fix for an Intel TSX (Transactional Synchronizations Extensions) sightings. The previous microcode was first introduced in the v2.62 System ROM. This issue only impacts systems configured with Intel Xeon&reg; D-1500 processors. This issue is not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U26","value":"HPE ProLiant Easy Connect EC200a Managed Hybrid Server"}],"sw_keys":[{"name":"U26","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300060","languages":[{"lang":"tw","x_late":"驅動程式 ─ 視訊"},{"lang":"en","x_late":"Driver - Video"},{"lang":"ko","x_late":"드라이버 - 비디오"},{"lang":"cn","x_late":"驱动程序 - 视频"},{"lang":"ja","x_late":"ドライバ - ビデオ"}]}],"description":[{"lang":"en","x_late":"This component provides advanced video support for the Matrox G200eH video controller."},{"lang":"ja","x_late":"このコンポーネントは、Matrox G200eHビデオ コントローラー対応の高度なビデオ機能を提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"cn","x_late":"服务器选项"},{"lang":"ja","x_late":"サーバ オプション"}]}],"documentation":[],"files":[{"bytes":"1603248","datemodified":"2019-07-19T14:20:45","file_list":["cp038692.xml","cpqsetup.exe","generic.dll","install.xml","Matrox.WddmUninstaller.exe","MxG2hDO64.sys","mxg2hs16.cat","MxG2hS16.inf"],"md5sum":"db41528c82a1cfa1b876de074a7194d2","name":"cp038692.exe","release":"2019-07-19T14:19:04","revision":"0","sha1sum":"6b9d4614f8add7fe575dc782f1e6286d08218c0d","size":"1MB","target_guids":[],"type_of_change":"0","version":"9.15.1.224"}],"id":{"product":"c64a84fd2c1c48b694ff9c49365c2913","version":"de2c0f0e28124d849c6fa5c0acf33c6f"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<P>Place the Smart Component in a temporary directory, then double-click it to run.</P>\n<P>Select \"Install\" to start extracting to a temporary location on the hard drive.</P>\n<P>Click the \"Install\" button to perform the driver installation.</P>"},{"lang":"ja","x_late":"<P>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。</P>\n<P>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。</P>\n<P>インストールボタンをクリックしてドライバーインストールを実行します。</P>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"Matrox G200eH Video Controller Driver for Windows Server 2016 and Server 2019"},{"lang":"ja","x_late":"Windows Server 2016および2019用Matrox G200eHビデオコントローラードライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"10000"},"supported_devices":[{"dev":"0533","subdev":"330E","subven":"103C","target_guid":"","type":"pci","ven":"102B"},{"dev":"0533","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"102B"}],"supported_operating_systems":[{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-09-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Add support for Windows Server 2019.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Fix for random screen corruption when changing resolution that could occur with driver versions 9.15.1.184 and 9.15.1.218.</li>\n\t<li>Fix for a display freeze that could occur when running the Windows Display Diagnostics tool (dispdiag.exe).</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"}],"sw_keys":[{"name":"MxG2hDO64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO1920JEUQQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSCPPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314f-3932-304a45555151","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: VO1920JEUQQ"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO1920JEUQQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for&nbsp;VMware ESXi&nbsp;- VO1920JEUQQ Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong>&nbsp;&nbsp;&nbsp;&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp; None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"16865614","datemodified":"2021-08-27T11:05:15","file_list":["/CP048419_BUILD_5.data","/CP048419.vmexe","/CP048419.vmexe64","/CP048419.vmfile","/CP048419_VMw.zip","/CP048419.xml","/payload.json","/CP048419_VMw.zip/index.xml","/CP048419_VMw.zip/vendor-index.xml","/CP048419_VMw.zip/metadata.zip","/CP048419_VMw.zip/vib20/CP048419/HPE_bootbank_CP048419_HPD3.5-7.0.0.15843807.vib","/CP048419_VMw.zip/metadata.zip/vendor-index.xml","/CP048419_VMw.zip/metadata.zip/vmware.xml","/CP048419_VMw.zip/metadata.zip/vibs/CP048419--811590486461629562.xml","/CP048419_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048419_HPD3.5-7.0.0.15843807.xml"],"md5sum":"777fbaeb32a5e8755303d932c4c0552f","name":"CP048419.zip","release":"2021-08-27T11:00:05","revision":"0","sha1sum":"3a091c58bbdecdf088b477f68eae9a900b3f7499","size":"16MB","target_guids":["002340a5-5600-314f-3932-304a45555151"],"type_of_change":"1","version":"HPD3","vib_list":[{"name":"CP048419","version":"HPD3.5-7.0.0.15843807"}]}],"id":{"product":"9735a485aa1b43118b5c393eba2635c1","version":"4b5461abca2d4d16966ab31fcfb3c5e8"},"installation":{"command":"CP040555.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VO1920JEUQQ Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VO1920JEUQQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VO1920JEUQQ","target_guid":"002340a5-5600-314f-3932-304a45555151","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T15:52:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO1920JEUQQ","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000480JWDAR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633LD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3438-304a57444152","Version":"HPD8"},{"DeviceName":"VO000960JWDAT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633LD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304a57444154","Version":"HPD8"},{"DeviceName":"VO001920JWDAU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633LD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304a57444155","Version":"HPD8"},{"DeviceName":"VO003840JWDAV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633LD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304a57444156","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO000480JWDAR, VO000960JWDAT, VO001920JWDAU and VO003840JWDAV"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO000480JWDAR、VO000960JWDAT、VO001920JWDAUおよびVO003840JWDAV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - VO000480JWDAR, VO000960JWDAT, VO001920JWDAU and VO003840JWDAV&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3260520","datemodified":"2021-07-25T21:39:03","file_list":["cp044739.xml","cpqsetup.exe","G1633LD8.rel","payload.json","setup.dll"],"md5sum":"39b2925453f33a26001e630eae45cfe0","name":"cp044739.exe","release":"2021-07-25T21:32:13","revision":"0","sha1sum":"7c32d062c33bcb625dd745f75c3e20776cb17580","size":"3MB","target_guids":["562340a5-304f-3030-3438-304a57444152","562340a5-304f-3030-3936-304a57444154","562340a5-304f-3130-3932-304a57444155","562340a5-304f-3330-3834-304a57444156"],"type_of_change":"2","version":"HPD8"}],"id":{"product":"38d33d1fd49e4ce68d34a95d7c8c3f1f","version":"f5419d7303514d568d381ec1624594b1"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VO000480JWDAR, VO000960JWDAT, VO001920JWDAU and VO003840JWDAV Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VO003840JWDAV","target_guid":"562340a5-304f-3330-3834-304a57444156","type":"sas"},{"id":"VO001920JWDAU","target_guid":"562340a5-304f-3130-3932-304a57444155","type":"sas"},{"id":"VO000960JWDAT","target_guid":"562340a5-304f-3030-3936-304a57444154","type":"sas"},{"id":"VO000480JWDAR","target_guid":"562340a5-304f-3030-3438-304a57444152","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-01T12:36:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO003840JWDAV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920JWDAU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000480JWDAR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000960JWDAT","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG0600JETKA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SED8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3630-304a45544b41","Version":"HPD8"},{"DeviceName":"EG0900JETKB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SED8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3930-304a45544b42","Version":"HPD8"},{"DeviceName":"EG1200JETKC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SED8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3230-304a45544b43","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG0600JETKA, EG0900JETKB, and EG1200JETKC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG0600JETKA,&nbsp;EG0900JETKB&nbsp;and&nbsp;EG1200JETKC Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4772998","datemodified":"2021-07-23T08:29:00","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-7505dfb5ae-HPD8-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-7505dfb5ae-HPD8-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-7505dfb5ae-HPD8-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7505dfb5ae-HPD8-2.1/CP048078.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-7505dfb5ae-HPD8-2.1/TA14SED8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-7505dfb5ae-HPD8-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7505dfb5ae-HPD8-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-7505dfb5ae-HPD8-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-7505dfb5ae-HPD8-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048078.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048078.scexe"],"md5sum":"fa73ded3fd9c883ccbb649d435e1ab02","name":"firmware-hdd-7505dfb5ae-HPD8-2.1.x86_64.rpm","release":"2021-07-23T08:16:12","revision":"0","sha1sum":"ed0fd27686c36a261286e87053ea0bbe2d56cd77","size":"4MB","target_guids":["002340a5-4500-3047-3630-304a45544b41","002340a5-4500-3047-3930-304a45544b42","002340a5-4500-3147-3230-304a45544b43"],"type_of_change":"1","version":"HPD8"}],"id":{"product":"b24d5f9d7d1b43c1891a12ff33223756","version":"1b239b50a6a64407a2f1b1be78f8a58a"},"installation":{"command":"CP040286.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64)  - EG0600JETKA, EG0900JETKB and EG1200JETKC Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - EG0600JETKA、EG0900JETKBおよびEG1200JETKCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EG1200JETKC","target_guid":"002340a5-4500-3147-3230-304a45544b43","type":"sas"},{"id":"EG0600JETKA","target_guid":"002340a5-4500-3047-3630-304a45544b41","type":"sas"},{"id":"EG0900JETKB","target_guid":"002340a5-4500-3047-3930-304a45544b42","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T10:52:33","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>A low-probability, high severity corner case of sustained outer-diameter activity with emergency power off when heads are at the outer diameter prevented heads from parking/latching properly on a few drives in the field.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG0900JETKB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG1200JETKC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0600JETKA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900374","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the boot BIOS and firmware of QLogic Fibre Channel host bus adapters."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"3605785","datemodified":"2021-08-31T07:08:21","file_list":["./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.3","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.3/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.3/.setup","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.3/CP048727.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.3/Q25A0382.BIN","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.3/adapters.properties","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.3/bk017507.bin","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.3/hld60404.bin","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.3/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.3/payload.json","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.3/qlafwupdate","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.3/qlafwupdate.properties","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.3/qlafwupdate.txt","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.3/reference.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.3/setup","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.3/x103Cx1939","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.3/x103Cx1939/BC26xx.DAT","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.3/x103Cx1939/FWA83xxB.DAT","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.3/x1590x00F9","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.3/x1590x00F9/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.3/x1590x00F9/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.3/x1590x00F9/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.3/x1590x00FA","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.3/x1590x00FA/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.3/x1590x00FA/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.3/x1590x00FA/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.3/x1590x0203","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.3/x1590x0203/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.3/x1590x0203/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.3/x1590x0203/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.3/x1590x0204","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.3/x1590x0204/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.3/x1590x0204/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.3/x1590x0204/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.3/x1590x022D","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.3/x1590x022D/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.3/x1590x022D/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.3/x1590x022D/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.3/x1590x02BC","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048727.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048727.scexe"],"md5sum":"e1cdd9e3bb28cd078bd60afa66fe8a0f","name":"firmware-fc-qlogic-2021.10.01-1.3.x86_64.rpm","release":"2021-08-31T06:56:45","revision":"0","sha1sum":"fe9e593c4f45760fcf93be481423e1e78911ed21","size":"3MB","target_guids":[],"type_of_change":"1","version":"2021.10.01"}],"id":{"product":"f7df18308cf6421586358b4d3e70b35d","version":"d0695c66fdb54adc8b489ecdceb44958"},"installation":{"command":"installer","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Firmware installation is a two-step process.&nbsp; Install the firmware installation tool rpm, then execute the installed tool to update the firmware.<br />\n&nbsp;<br />\n1. Install the firmware installation tool:&nbsp; rpm -Uvh &lt;rpm_package_name&gt;.rpm&nbsp; This extracts the firmware installation tool to /usr/lib/x86_64-linux-gnu (64-bit systems)&nbsp;in an firmware-* folder.<br />\n&nbsp;<br />\n2. cd to the appropriate location for your system, and update the firmware by executing ./setup<br />\n&nbsp;<br />\nWhen the firmware installation completes, you may remove the firmware installation tool from your system using the rpm -e command.</p>\n\n<p>NOTE: During the flash operation, the message &quot;No Adapter Found!&quot; may appear in the logs. These messages do not indicate a problem with the firmware flash operation and may be ignored.</p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>\n\t<p>It is advised to provide read-write permissions on /var/tmp folder. Firmware deployment via Service Pack for ProLiant(SPP) might be unsuccessful in some cases , if read-write(rw) permissions are not enable on /tmp or /var/tmp directories.</p>\n\t</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for QLogic Fibre Channel Host Bus Adapters - Linux (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-18T06:47:41","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Speed</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">MBI</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Firmware</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">UEFI</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Boot Bios</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE 81Q 8Gb PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.82.00</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8.08.207</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.00</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.56</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE 82Q 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.82.00</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8.08.207</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.00</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.56</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE 84Q 8Gb Quad Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.82.00</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8.08.207</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.00</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.56</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1000Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">6.04.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8.08.232</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.43</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1000Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">6.04.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8.08.232</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.43</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">1.75.07</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">9.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.64</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">1.75.07</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">9.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.64</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">1.75.07</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">9.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.64</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">1.75.07</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">9.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.64</p>\n\t\t\t</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"QLOGIC","sw_key_expectedpath":"firmware:QLOGIC"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the SRIOV virtual function drivers for the HPE Blade Intel ixgbe Ethernet NICs running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 8で動作するHPE Blade Intel ixgbe Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"55533","datemodified":"2021-07-21T17:54:23","file_list":["./etc/depmod.d/hp-ixgbevf.conf","./lib/modules/4.18.0-193.el8.x86_64","./lib/modules/4.18.0-193.el8.x86_64/extra","./lib/modules/4.18.0-193.el8.x86_64/extra/hp-ixgbevf","./lib/modules/4.18.0-193.el8.x86_64/extra/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/kmod-hp-ixgbevf_bl/component.xml"],"md5sum":"14a9a554562a4d34270802b881e098d2","name":"kmod-hp-ixgbevf_bl-4.9.3-1.rhel8u2.x86_64.rpm","release":"2021-07-21T17:49:04","revision":"0","sha1sum":"e707ca288a43f5737b0ae4a9d7bd5f32900d7fdc","size":"54KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec674b05ac"],"type_of_change":"0","version":"4.9.3-1"},{"bytes":"55676","datemodified":"2021-07-21T17:57:06","file_list":["./etc/depmod.d/hp-ixgbevf.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/hp-ixgbevf","./lib/modules/4.18.0-240.el8.x86_64/extra/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/kmod-hp-ixgbevf_bl/component.xml"],"md5sum":"a968050da10613760865e9119a85faed","name":"kmod-hp-ixgbevf_bl-4.9.3-2.rhel8u3.x86_64.rpm","release":"2021-07-21T17:49:04","revision":"0","sha1sum":"a822a79a1ec3112dfc563f454f8f885e9f94992a","size":"54KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec674b05ac"],"type_of_change":"0","version":"4.9.3-1"}],"id":{"product":"1645a3fa489f4a55a83d6b3479318292","version":"afe13ed3ddaf4aacbb7cb07f9cc31294"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>\n\n<p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>\n\n<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>\n\n<p> </p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Intel ixgbevf Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE Blade Intel ixgbevfドライバー for Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c18d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-09-03T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 8, Updates 2&nbsp;and 3.</p>\n","latest_fixes_x_late":"<p>This product corrects an issue seen when enabling SRIOV, where the VFs have the same, duplicated MAC address.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports the&nbsp;HPE ProLiant BL660c Gen9 Server.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"kmod-hp-ixgbevf_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbevf_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbevf_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbevf_bl","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960RWUEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALSHPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554556","Version":"HPD6"},{"DeviceName":"VO001920RWUFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALSHPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554641","Version":"HPD6"},{"DeviceName":"VO003840RWUFB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALSHPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554642","Version":"HPD6"},{"DeviceName":"VO007680RWUFC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALSHPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-305257554643","Version":"HPD6"},{"DeviceName":"VO000960RWUFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALSHPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554644","Version":"HPD6"},{"DeviceName":"VO001920RWUFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALSHPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554645","Version":"HPD6"},{"DeviceName":"VO003840RWUFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALSHPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554646","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO000960RWUEV、VO001920RWUFA、VO003840RWUFB、VO007680RWUFC、VO000960RWUFD、VO001920RWUFE およびVO003840RWUFF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi&nbsp;- VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Reduced the occurrence probability of PMIC busy issue.&nbsp;</li>\n\t<li>Fixed the system data error at the drive power on issue.&nbsp;</li>\n\t<li>When the PLP operation starts, the waiting Unmap request to the 4KB not-aligned host write area is canceled to be able to complete PLP correctly.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"17136466","datemodified":"2021-08-30T08:09:27","file_list":["/CP049363_BUILD_1.data","/CP049363.vmexe","/CP049363.vmexe64","/CP049363.vmfile","/CP049363_VMw.zip","/CP049363.xml","/payload.json","/CP049363_VMw.zip/index.xml","/CP049363_VMw.zip/vendor-index.xml","/CP049363_VMw.zip/metadata.zip","/CP049363_VMw.zip/vib20/CP049363/HPE_bootbank_CP049363_HPD6.1-7.0.0.15843807.vib","/CP049363_VMw.zip/metadata.zip/vendor-index.xml","/CP049363_VMw.zip/metadata.zip/vmware.xml","/CP049363_VMw.zip/metadata.zip/vibs/CP049363-2304080808850321206.xml","/CP049363_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049363_HPD6.1-7.0.0.15843807.xml"],"md5sum":"c0b2931e9cf9d814e3be230a2844e9e2","name":"CP049363.zip","release":"2021-08-30T08:04:16","revision":"0","sha1sum":"13f0d8ed25e7148c8ea7702f29c2b2e6863fbd60","size":"16MB","target_guids":["562340a5-304f-3030-3936-305257554556","562340a5-304f-3130-3932-305257554641","562340a5-304f-3330-3834-305257554642","562340a5-304f-3730-3638-305257554643","562340a5-304f-3030-3936-305257554644","562340a5-304f-3130-3932-305257554645","562340a5-304f-3330-3834-305257554646"],"type_of_change":"1","version":"HPD6","vib_list":[{"name":"CP049363","version":"HPD6.1-7.0.0.15843807"}]}],"id":{"product":"cf7cb50c769b4b00ab89aa81d9fac797","version":"4e8c9fda9e934fb19bb6436ad7d1746b"},"installation":{"command":"CP041554.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします。</li>\n\t<li>CPXXXXXX.vmexe(ESXi 6.7 &以前のバージョン)およびCPXXXXXX.vmexe64(ESXi 7.0)は、次のコマンドを使用して実行可能です:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod x CPXXXXXX.vmexe    または    chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPXXXXXX.vmexe(または)./CPXXXXXX.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi -  VO000960RWUEV、VO001920RWUFA、VO003840RWUFB、VO007680RWUFC、VO000960RWUFD、VO001920RWUFE およびVO003840RWUFFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VO007680RWUFC","target_guid":"562340a5-304f-3730-3638-305257554643","type":"sas"},{"id":"VO003840RWUFF","target_guid":"562340a5-304f-3330-3834-305257554646","type":"sas"},{"id":"VO003840RWUFB","target_guid":"562340a5-304f-3330-3834-305257554642","type":"sas"},{"id":"VO001920RWUFE","target_guid":"562340a5-304f-3130-3932-305257554645","type":"sas"},{"id":"VO001920RWUFA","target_guid":"562340a5-304f-3130-3932-305257554641","type":"sas"},{"id":"VO000960RWUFD","target_guid":"562340a5-304f-3030-3936-305257554644","type":"sas"},{"id":"VO000960RWUEV","target_guid":"562340a5-304f-3030-3936-305257554556","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-26T06:50:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Change Vendor Identification Field (VID data) from &quot;HP&quot; to &quot;HPE&quot;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Reduced the occurrence probability of PMIC busy issue.&nbsp;</li>\n\t<li>Fixed the system data error at the drive power on issue.&nbsp;</li>\n\t<li>When the PLP operation starts, the waiting Unmap request to the 4KB not-aligned host write area is canceled to be able to complete PLP correctly.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO000960RWUFD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO007680RWUFC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000960RWUEV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003840RWUFB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003840RWUFF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920RWUFA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920RWUFE","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel and Blade Storage Mezzanine Fibre Channel over Ethernet Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"3324818","datemodified":"2021-09-07T07:40:23","file_list":["./etc/depmod.d/brcmfcoe.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/brcmfcoe","./lib/modules/3.10.0-1127.el7.x86_64/extra/brcmfcoe/brcmfcoe.ko","./usr/share/smartupdate/kmod-brcmfcoe/component.xml"],"md5sum":"0eb67103e11d37d4c3275dcdcc52d07f","name":"kmod-brcmfcoe-12.0.1342.0-1.rhel7u8.x86_64.rpm","release":"2021-09-07T07:27:51","revision":"0","sha1sum":"2a38f34baa09992dab5e9b6d10883290c1417688","size":"3MB","target_guids":[],"type_of_change":"1","version":"12.0.1342.0"}],"id":{"product":"80134b7743cb4cbd95145cdaadb88deb","version":"fbc8b875fd15474a99f5e2eb1d44e341"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh brcmfcoe-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh brcmfcoe-kmp-default-11.2.xxxx.x_3.0.76._0.11-1.sles11sp3.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e brcmfcoe-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Red Hat Enterprise Linux 7 Update 8 Server Fibre Channel over Ethernet (FCoE) Driver Kit for HPE Storage Emulex(BRCM) Converged Network Adapters and mezzanine Converged Network Adapters(CNAs)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T11:00:43","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to Driver version 12.0.1342.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"}],"sw_keys":[{"name":"kmod-brcmfcoe","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel and Mezzanine Host Bus Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"596545","datemodified":"2021-08-26T08:29:09","file_list":["./etc/depmod.d/lpfc.conf","./etc/dracut.conf.d/lpfc.conf","./lib/modules/4.18.0-305.el8.x86_64","./lib/modules/4.18.0-305.el8.x86_64/extra","./lib/modules/4.18.0-305.el8.x86_64/extra/elx-lpfc","./lib/modules/4.18.0-305.el8.x86_64/extra/elx-lpfc/lpfc.ko","./usr/share/smartupdate/kmod-elx-lpfc/component.xml"],"md5sum":"21ae3e4637985aae6ab1bdcaa75f866e","name":"kmod-elx-lpfc-12.8.528.7-1.rhel8u4.x86_64.rpm","release":"2021-08-26T08:21:04","revision":"0","sha1sum":"02cb7d0b47b1891a673fc6f5c2fd982bc10bc75e","size":"582KB","target_guids":[],"type_of_change":"1","version":"12.8.528.7"}],"id":{"product":"be8c87f10c214203ae9850dc0a417aeb","version":"9ed0cca97e3542f2b9b7cbe34af1a205"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-elx-lpfc-12.8.509.3-1.rhel8u4.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Red Hat Enterprise Linux 8 Update 4 Server Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters and Mezzanine Host Bus Adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"F100","subven":"10DF","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T10:36:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added the following support:</p>\n\n<ul>\n\t<li>Added support for RHEL 8.4</li>\n</ul>\n\n<p>Updated to driver version 12.8.528.7</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"kmod-elx-lpfc","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK003840GWSXL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M52004G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-30475753584c","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: VK003840GWSXL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;VK003840GWSXL Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG2</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG2<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3139704","datemodified":"2021-07-25T18:59:24","file_list":["cp048639.xml","cpqsetup.exe","M52004G3.rel","payload.json","setup.dll"],"md5sum":"cea207e496fe06b6f70c26486d3797a8","name":"cp048639.exe","release":"2021-07-25T18:52:06","revision":"0","sha1sum":"69ce051ddad4a48ca739e40b56aa64b4658afdde","size":"2MB","target_guids":["562340a5-304b-3330-3834-30475753584c"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"121ced484e6647bf98b3a4bca60530c2","version":"70781bbc0f16405ab48711473474efaa"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK003840GWSXL  Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - VK003840GWSXL ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VK003840GWSXL","target_guid":"562340a5-304b-3330-3834-30475753584c","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T16:57:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Improved Product Quality and Reliability. Changed Cap Charge Timeout to 14 seconds from 4 seconds to provide additional time for cap charge in marginal power environment.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK003840GWSXL","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the SRIOV virtual function drivers for the HPE Intel ixgbe Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Intel ixgbe Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1229724","datemodified":"2021-01-09T00:03:34","file_list":["./etc/depmod.d/hp-ixgbevf.conf","./etc/dracut.conf.d/hp-ixgbevf-oob.conf","./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/hp-ixgbevf","./lib/modules/5.3.18-22-default/updates/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/hp-ixgbevf-kmp-default/component.xml"],"md5sum":"904b263327d6629752ccc1aa0ffdbb76","name":"hp-ixgbevf-kmp-default-4.9.3_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-01-08T23:47:06","revision":"0","sha1sum":"15c5aa948fbdb4243bd87c018d547e0264ebf647","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecc0badb49"],"type_of_change":"0","version":"4.9.3-1"},{"bytes":"1051756","datemodified":"2021-01-09T00:11:18","file_list":["./etc/depmod.d/hp-ixgbevf.conf","./etc/dracut.conf.d/hp-ixgbevf-oob.conf","./lib/modules/4.12.14-195-default","./lib/modules/4.12.14-195-default/updates","./lib/modules/4.12.14-195-default/updates/hp-ixgbevf","./lib/modules/4.12.14-195-default/updates/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/hp-ixgbevf-kmp-default/component.xml"],"md5sum":"7a9b4c53e8af5825939776d0ca63e0e4","name":"hp-ixgbevf-kmp-default-4.9.3_k4.12.14_195-1.sles15sp1.x86_64.rpm","release":"2021-01-08T23:47:06","revision":"0","sha1sum":"c5c80884312d46c5c0c813fed605e6d58adf7ac0","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecc0badb49"],"type_of_change":"0","version":"4.9.3-1"}],"id":{"product":"58259b45dec7469580dfbddb76171768","version":"c2e41e97e88146d4a8a621f0c2dbbfc5"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"},{"lang":"ja","x_late":"<p>インストールのノートについてREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Intel ixgbevf Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE Intel ixgbevfドライバーfor SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c192d","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c211a","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"},{"dev":"152E","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d3","type":"pci","ven":"8086"},{"dev":"1530","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"1515","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c192d","type":"pci","ven":"8086"},{"dev":"1515","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c211a","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product update Linux kernel documentation and Configure IRQ affinity tools</p>\n","latest_fixes_x_late":"<p>This product corrects an issue which errata kernel loads inbox driver instead of this component after booting into OS</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>This product now supports Suse Linux Enterprise Server 15 Service Pack 2</li>\n\t<li>This product enhances reliability via adding support for new mailbox communication between PF(Physical Function) and VF(Virtual Function) and remove its potential flaws that may lead to the undefined or faulty behavior</li>\n\t<li>This product enhances compatibility where new mailbox api implementation is alo compatible with old drivers</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"hp-ixgbevf-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbevf-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbevf-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbevf-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB002000JWFVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATRsnSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a5746564e","Version":"HPD4"},{"DeviceName":"MB004000JWFVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATRsnSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a57465650","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB002000JWFVN and MB004000JWFVP"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB002000JWFVN and MB004000JWFVP&nbsp;Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp; &nbsp; &nbsp;&nbsp;Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3035176","datemodified":"2021-07-23T19:08:47","file_list":["cp048560.xml","cpqsetup.exe","payload.json","setup.dll","TATCATRsnSD4.REL"],"md5sum":"7ef786214429f7cab7efbc8cc212bfd7","name":"cp048560.exe","release":"2021-07-23T19:01:05","revision":"0","sha1sum":"81e077fb3faa201fecd143c453ad57cc58658349","size":"2MB","target_guids":["4d2340a5-3042-3230-3030-304a5746564e","4d2340a5-3042-3430-3030-304a57465650"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"2b0745f5d1b9423aa88e57ad4cdfbe00","version":"babc897cb01e43a2b63828a1da6dc53c"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB002000JWFVN and MB004000JWFVP Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB002000JWFVNおよびMB004000JWFVPドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB002000JWFVN","target_guid":"4d2340a5-3042-3230-3030-304a5746564e","type":"sas"},{"id":"MB004000JWFVP","target_guid":"4d2340a5-3042-3430-3030-304a57465650","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T06:16:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware provides a change to the Vendor ID in the VPD page that refers to HP instead of HPE.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB002000JWFVN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB004000JWFVP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK0240GEPQN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM853G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3234-30474550514e","Version":"HPG1"},{"DeviceName":"VK0480GEPQP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM853G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3438-304745505150","Version":"HPG1"},{"DeviceName":"VK0960GEPQQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM853G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3936-304745505151","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK0240GEPQN, VK0480GEPQP and VK0960GEPQQ Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VK0240GEPQN、VK0480GEPQP、およびVK0960GEPQQドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;-&nbsp;&nbsp;VK0240GEPQN, VK0480GEPQP&nbsp;and VK0960GEPQQ Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4774659","datemodified":"2021-07-23T08:58:41","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-1a516522d1-HPG1-9.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a516522d1-HPG1-9.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a516522d1-HPG1-9.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a516522d1-HPG1-9.1/CP048193.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a516522d1-HPG1-9.1/GPM853G1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a516522d1-HPG1-9.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a516522d1-HPG1-9.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a516522d1-HPG1-9.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a516522d1-HPG1-9.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048193.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048193.scexe"],"md5sum":"c7a129023513fa75a85d2e9a6246f888","name":"firmware-hdd-1a516522d1-HPG1-9.1.x86_64.rpm","release":"2021-07-23T08:46:11","revision":"0","sha1sum":"cb4f20432d6e103defd245a002e9c9dd064703f7","size":"4MB","target_guids":["002340a5-5600-304b-3234-30474550514e","002340a5-5600-304b-3438-304745505150","002340a5-5600-304b-3936-304745505151"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"86fd494457ed46feb0f879467158193c","version":"22cd8f79724143e6b35259888e864a83"},"installation":{"command":"CP040297.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK0240GEPQN, VK0480GEPQP and VK0960GEPQQ Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64)- VK0240GEPQN、VK0480GEPQP、およびVK0960GEPQQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VK0240GEPQN","target_guid":"002340a5-5600-304b-3234-30474550514e","type":"sata"},{"id":"VK0480GEPQP","target_guid":"002340a5-5600-304b-3438-304745505150","type":"sata"},{"id":"VK0960GEPQQ","target_guid":"002340a5-5600-304b-3936-304745505151","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T10:34:08","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK0960GEPQQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0240GEPQN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0480GEPQP","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GWXFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757584646","Version":"HPG2"},{"DeviceName":"MK000960GWXFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757584648","Version":"HPG2"},{"DeviceName":"MK001920GWXFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475758464b","Version":"HPG2"},{"DeviceName":"MK003840GWXFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475758464c","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG1</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG1<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>This&nbsp;FW release deploys an Enhanced Media Scan algorithm that addresses an issue when the host system does not provide enough idle time for drive&rsquo;s Foreground Media Scan to be activated, which is needed to ensure long term drive reliability. It also addresses few minor issues.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"9260797","datemodified":"2021-08-17T11:23:43","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG2-1.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG2-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG2-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG2-1.1/CP049301.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG2-1.1/K503HPG2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG2-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG2-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG2-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG2-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049301.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049301.scexe"],"md5sum":"b9590fc65410041a95900f0e51eda985","name":"firmware-hdd-8e1e8083c5-HPG2-1.1.x86_64.rpm","release":"2021-08-17T11:10:04","revision":"0","sha1sum":"5d3a8db7b677fcddc1119b7642f856f6c8c51e55","size":"8MB","target_guids":["4d2340a5-304b-3030-3438-304757584646","4d2340a5-304b-3030-3936-304757584648","4d2340a5-304b-3130-3932-30475758464b","4d2340a5-304b-3330-3834-30475758464c"],"type_of_change":"1","version":"HPG2"}],"id":{"product":"24bbe0adc4dc4c7385b6f5ad6aecf867","version":"2b767913d9d943e893ed3900eb2a17ae"},"installation":{"command":"CP043280.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for Linux(x64)- MK000480GWXFF、 MK000960GWXFH、MK001920GWXFKおよびMK003840GWXFLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MK003840GWXFL","target_guid":"4d2340a5-304b-3330-3834-30475758464c","type":"sata"},{"id":"MK001920GWXFK","target_guid":"4d2340a5-304b-3130-3932-30475758464b","type":"sata"},{"id":"MK000960GWXFH","target_guid":"4d2340a5-304b-3030-3936-304757584648","type":"sata"},{"id":"MK000480GWXFF","target_guid":"4d2340a5-304b-3030-3438-304757584646","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-17T11:00:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>&nbsp;Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<p>This&nbsp;FW release deploys an Enhanced Media Scan algorithm that addresses an issue when the host system does not provide enough idle time for drive&rsquo;s Foreground Media Scan to be activated, which is needed to ensure long term drive reliability. It also addresses few minor issues.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK001920GWXFK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWXFH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK003840GWXFL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWXFF","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG1800JEMDB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBT2D5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3830-304a454d4442","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: EG1800JEMDB"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：EG1800JEMDB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG0300JFCKA, EG0600JEMCV, EG0900JFCKB&nbsp;and EG1200JEMDA Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None&nbsp;</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"5643407","datemodified":"2021-07-23T08:26:43","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-0a38b25661-HPD5-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a38b25661-HPD5-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a38b25661-HPD5-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a38b25661-HPD5-8.1/CP048081.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a38b25661-HPD5-8.1/STHBT2D5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a38b25661-HPD5-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a38b25661-HPD5-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a38b25661-HPD5-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a38b25661-HPD5-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048081.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048081.scexe"],"md5sum":"e8cd24e3c3a0196be3974351463f2a53","name":"firmware-hdd-0a38b25661-HPD5-8.1.x86_64.rpm","release":"2021-07-23T08:14:05","revision":"0","sha1sum":"da4b7852be15615249b1cfa585c535304e22e386","size":"5MB","target_guids":["002340a5-4500-3147-3830-304a454d4442"],"type_of_change":"1","version":"HPD5"}],"id":{"product":"d2428e35050d42c7ba121ca5de5ea63c","version":"023db66966fd4b6e864b4f10965ad8a4"},"installation":{"command":"CP040287.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EG1800JEMDB Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - EG1800JEMDBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EG1800JEMDB","target_guid":"002340a5-4500-3147-3830-304a454d4442","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T11:01:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG1800JEMDB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"The HPE Storage Fibre Channel (FC) adapter kit contains version 12.8.351.7 of the Emulex Storport driver for Extended Systems which provides Fibre Channel-Host Bus Adapter (HBA) driver support for HPE Storage RAID Arrays."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"2309384","datemodified":"2021-08-26T07:30:40","file_list":["cp048601.xml","cpqsetup.exe","elxdrvr-fc-12.8.351.7-13.exe","ElxStorInstaller.dll","install.xml","SysConfig.frm","SysConfig.frm.ja"],"md5sum":"4f4a28b1625a96d5fe61125e488d3cbe","name":"cp048601.exe","release":"2021-08-26T07:27:33","revision":"0","sha1sum":"ecb109fec4ee639caffa209d3845d40bb084dd3b","size":"2MB","target_guids":[],"type_of_change":"1","version":"12.8.351.7"}],"id":{"product":"2311bd74c11b41cab44912e7067c4e80","version":"9e125a820da54e7985800d3652254b05"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation.</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Fibre Channel Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"F100","subven":"10DF","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T10:35:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to driver version&nbsp;12.8.351.7</p>\n\n<p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p>\n\n<p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p>\n\n<p>The extracted files are located:</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p>\n\n<p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2019</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"elxfc.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000240GWCEU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3234-304757434555","Version":"HPG3"},{"DeviceName":"MK000480GWCEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757434556","Version":"HPG3"},{"DeviceName":"MK000960GWCFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757434641","Version":"HPG3"},{"DeviceName":"MK001920GWCFB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304757434642","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MK000240GWCEU, MK000480GWCEV, MK000960GWCFA and MK001920GWCFB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MK000240GWCEU, MK000480GWCEV, MK000960GWCFA and&nbsp;MK001920GWCFB Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"15796724","datemodified":"2021-08-27T06:48:38","file_list":["/CP048390_BUILD_2.data","/CP048390.vmexe","/CP048390.vmexe64","/CP048390.vmfile","/CP048390_VMw.zip","/CP048390.xml","/payload.json","/CP048390_VMw.zip/index.xml","/CP048390_VMw.zip/vendor-index.xml","/CP048390_VMw.zip/metadata.zip","/CP048390_VMw.zip/vib20/CP048390/HPE_bootbank_CP048390_HPG3.2-7.0.0.15843807.vib","/CP048390_VMw.zip/metadata.zip/vendor-index.xml","/CP048390_VMw.zip/metadata.zip/vmware.xml","/CP048390_VMw.zip/metadata.zip/vibs/CP048390-6565617751817706618.xml","/CP048390_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048390_HPG3.2-7.0.0.15843807.xml"],"md5sum":"213175046eab0980f2d79169c642895c","name":"CP048390.zip","release":"2021-08-27T06:43:48","revision":"0","sha1sum":"93a7ad1407ad0c69518b2dfba6347ec463e069c5","size":"15MB","target_guids":["4d2340a5-304b-3030-3234-304757434555","4d2340a5-304b-3030-3438-304757434556","4d2340a5-304b-3030-3936-304757434641","4d2340a5-304b-3130-3932-304757434642"],"type_of_change":"1","version":"HPG3","vib_list":[{"name":"CP048390","version":"HPG3.2-7.0.0.15843807"}]}],"id":{"product":"568141f535e3461e90494d5ac58c3991","version":"46833a0f1e6949838b4b3067ba4bd367"},"installation":{"command":"CP040679.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MK000240GWCEU, MK000480GWCEV, MK000960GWCFA and MK001920GWCFB  Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MK000240GWCEU、MK000480GWCEV、MK000960GWCFAおよびMK001920GWCFBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MK001920GWCFB","target_guid":"4d2340a5-304b-3130-3932-304757434642","type":"sata"},{"id":"MK000960GWCFA","target_guid":"4d2340a5-304b-3030-3936-304757434641","type":"sata"},{"id":"MK000480GWCEV","target_guid":"4d2340a5-304b-3030-3438-304757434556","type":"sata"},{"id":"MK000240GWCEU","target_guid":"4d2340a5-304b-3030-3234-304757434555","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T11:06:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK000240GWCEU","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWCFA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK001920GWCFB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWCEV","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MR000240GWFLU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3234-304757464c55","Version":"HPGG"},{"DeviceName":"MR000480GWFLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3438-304757464c56","Version":"HPGG"},{"DeviceName":"VR000480GWFMD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3438-304757464d44","Version":"HPGG"},{"DeviceName":"MR000960GWFMA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3936-304757464d41","Version":"HPGG"},{"DeviceName":"VR000960GWFME","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3936-304757464d45","Version":"HPGG"},{"DeviceName":"MR001920GWFMB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3130-3932-304757464d42","Version":"HPGG"},{"DeviceName":"VR001920GWFMC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3130-3932-304757464d43","Version":"HPGG"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MR000240GWFLU, MR000480GWFLV, VR000480GWFMD, MR000960GWFMA, VR000960GWFME, MR001920GWFMB and VR001920GWFMC Drives"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MR000240GWFLU, MR000480GWFLV, VR000480GWFMD, MR000960GWFMA, VR000960GWFME, MR001920GWFMB&nbsp;and VR001920GWFMC Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGG<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGE<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPGE</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"16471512","datemodified":"2021-08-27T07:44:07","file_list":["/CP048402_BUILD_3.data","/CP048402.vmexe","/CP048402.vmexe64","/CP048402.vmfile","/CP048402_VMw.zip","/CP048402.xml","/payload.json","/CP048402_VMw.zip/index.xml","/CP048402_VMw.zip/vendor-index.xml","/CP048402_VMw.zip/metadata.zip","/CP048402_VMw.zip/vib20/CP048402/HPE_bootbank_CP048402_HPGG.3-7.0.0.15843807.vib","/CP048402_VMw.zip/metadata.zip/vendor-index.xml","/CP048402_VMw.zip/metadata.zip/vmware.xml","/CP048402_VMw.zip/metadata.zip/vibs/CP048402--5405200051967956877.xml","/CP048402_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048402_HPGG.3-7.0.0.15843807.xml"],"md5sum":"148c074d7cb05f506fdf7877c2750e33","name":"CP048402.zip","release":"2021-08-27T07:38:51","revision":"0","sha1sum":"5d6476a1eb98650cea28a476d1e2f9547fb580bc","size":"15MB","target_guids":["4d2340a5-3052-3030-3234-304757464c55","4d2340a5-3052-3030-3438-304757464c56","562340a5-3052-3030-3438-304757464d44","4d2340a5-3052-3030-3936-304757464d41","562340a5-3052-3030-3936-304757464d45","4d2340a5-3052-3130-3932-304757464d42","562340a5-3052-3130-3932-304757464d43"],"type_of_change":"1","version":"HPGG","vib_list":[{"name":"CP048402","version":"HPGG.3-7.0.0.15843807"}]}],"id":{"product":"d2d1d9a632e643969f5a1799b83f981a","version":"cbe86d0b561642559c503dd3dd0302e2"},"installation":{"command":"CP041315.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>HP Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MR000240GWFLU, MR000480GWFLV, VR000480GWFMD, MR000960GWFMA, VR000960GWFME, MR001920GWFMB and VR001920GWFMC Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MR000240GWFLU、MR000480GWFLV、VR000480GWFMD、MR000960GWFMA、VR000960GWFME、MR001920GWFMBおよびVR001920GWFMCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VR001920GWFMC","target_guid":"562340a5-3052-3130-3932-304757464d43","type":"sata"},{"id":"MR001920GWFMB","target_guid":"4d2340a5-3052-3130-3932-304757464d42","type":"sata"},{"id":"VR000960GWFME","target_guid":"562340a5-3052-3030-3936-304757464d45","type":"sata"},{"id":"MR000960GWFMA","target_guid":"4d2340a5-3052-3030-3936-304757464d41","type":"sata"},{"id":"VR000480GWFMD","target_guid":"562340a5-3052-3030-3438-304757464d44","type":"sata"},{"id":"MR000480GWFLV","target_guid":"4d2340a5-3052-3030-3438-304757464c56","type":"sata"},{"id":"MR000240GWFLU","target_guid":"4d2340a5-3052-3030-3234-304757464c55","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T19:55:23","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Improvements to Product Quality and Reliability.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MR000480GWFLV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MR000960GWFMA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VR001920GWFMC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VR000960GWFME","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MR001920GWFMB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VR000480GWFMD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MR000240GWFLU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO1920JEUQQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSCPPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314f-3932-304a45555151","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: VO1920JEUQQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - VO1920JEUQQ Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong>&nbsp;&nbsp;&nbsp;&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp; None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3336256","datemodified":"2021-07-25T19:46:37","file_list":["cp048645.xml","cpqsetup.exe","HSCPPCD3.rel","payload.json","setup.dll"],"md5sum":"c91883a7446e2d44a9f55f4d25e65719","name":"cp048645.exe","release":"2021-07-25T19:39:04","revision":"0","sha1sum":"3e3fb91e1bc58a4afce9a584946043f81a2085b0","size":"3MB","target_guids":["002340a5-5600-314f-3932-304a45555151"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"cbed2371ac3f4cd6a3df13f0ee8daa7b","version":"fe0102deebe242f8a8bf4886b7c775b8"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"text-decoration-line: none; color: blue;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VO1920JEUQQ Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - VO1920JEUQQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VO1920JEUQQ","target_guid":"002340a5-5600-314f-3932-304a45555151","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T17:59:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO1920JEUQQ","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Broadcom NetXtreme-E NICs running under Red Hat Enterprise Linux 7."},{"lang":"ja","x_late":"この製品は、Red Hat Enterprise Linux 7下で動作するHPE Broadcom NetXtreme-E NIC用のドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"319902","datemodified":"2021-01-14T08:20:33","file_list":["./etc/depmod.d/bnxt_en.conf","./etc/depmod.d/bnxt_re.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/bnxt_en","./lib/modules/3.10.0-1160.el7.x86_64/extra/bnxt_en/bnxt_en.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/bnxt_en/drivers","./lib/modules/3.10.0-1160.el7.x86_64/extra/bnxt_en/drivers/infiniband","./lib/modules/3.10.0-1160.el7.x86_64/extra/bnxt_en/drivers/infiniband/hw","./lib/modules/3.10.0-1160.el7.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re","./lib/modules/3.10.0-1160.el7.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/share/smartupdate/kmod-bnxt_en/component.xml"],"md5sum":"de3c2678b31541308de26f8eea283e22","name":"kmod-bnxt_en-1.10.2-218.0.67.0.rhel7u9.x86_64.rpm","release":"2021-01-14T07:51:05","revision":"0","sha1sum":"b40da9b184f458badf86ed73361d7a3f7fc183b9","size":"312KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af"],"type_of_change":"0","version":"1.10.2-218.0.67.0"},{"bytes":"319889","datemodified":"2021-01-14T08:08:45","file_list":["./etc/depmod.d/bnxt_en.conf","./etc/depmod.d/bnxt_re.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/bnxt_en","./lib/modules/3.10.0-1127.el7.x86_64/extra/bnxt_en/bnxt_en.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/bnxt_en/drivers","./lib/modules/3.10.0-1127.el7.x86_64/extra/bnxt_en/drivers/infiniband","./lib/modules/3.10.0-1127.el7.x86_64/extra/bnxt_en/drivers/infiniband/hw","./lib/modules/3.10.0-1127.el7.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re","./lib/modules/3.10.0-1127.el7.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/share/smartupdate/kmod-bnxt_en/component.xml"],"md5sum":"4f578806361dbc760ea2ee88327d5bbe","name":"kmod-bnxt_en-1.10.2-218.0.67.0.rhel7u8.x86_64.rpm","release":"2021-01-14T07:51:05","revision":"0","sha1sum":"bf3a3371d7bab25d2320259df27b0a155b210857","size":"312KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af"],"type_of_change":"0","version":"1.10.2-218.0.67.0"}],"id":{"product":"8f50751a2a4c4c6eac4753b883c9d78b","version":"262c2c428cc447eebcaf0976442857d2"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>Download README for any additional installation instructions.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E Drivers for Red Hat Enterprise Linux 7"},{"lang":"ja","x_late":"HPE Broadcom NetXtreme-Eドライバーfor Red Hat Enterprise Linux 7"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>This product now supports Red Hat Enterprise Linux 7 Update 8</li>\n\t<li>This product now sets Maximum Transmission Unit(MTU) default value from firmware returned value</li>\n\t<li>This product now not support user establishing connections using RDMA communication manager(CM) when Priority-based Flow Control (PFC) configured VLAN ID is 0</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>This product corrects an issue which offload is not happening on bond(vf and virtio) interface after the fail over with VF as the active slave</li>\n\t<li>This product corrects an issue which driver loading failed on kdump kernel.</li>\n\t<li>This product corrects an issue which RoCE driver causes input&ndash;output memory management unit(IOMMU) warnings</li>\n\t<li>This product corrects an issue which RoCE Link Aggregation (RoCE LAG) when Maximum Transmission Unit(MTU) was changed.</li>\n\t<li>This product corrects an issue which Link up failed after resuming from hibernation</li>\n\t<li>This product corrects an issue which Virtual Function RoCE driver causes Virtual Machine to be rebooted</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>This product now supports Red Hat Enterprise Linux 7 update 9</li>\n\t<li>This product now supports PAM4 speeds information in&nbsp;ethtool tools&nbsp;</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where system crashed on doing driver unload load in loop when running broadcast traffic</li>\n\t<li>This product addresses an issue where bnxt_en module crashes with NULL pointer deference before ifup(bring up network interface)</li>\n\t<li>This product addresses an issue where kernel panic after PCIe AER(Advanced Error Reporting) device recovery successful</li>\n\t<li>This product addresses an issue where bnxt_en crashes with NULL pointer dereference when enabling SRIOV</li>\n\t<li>This product correct an error where ethtool -S tx_bytes and rx_bytes counter values far exceed actual values</li>\n\t<li>This product correct an error message when querying hwmon temperature on VF via sysfs</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-bnxt_en","sw_key_expectedpath":"software:rpm"},{"name":"kmod-bnxt_en","sw_key_expectedpath":"software:rpm"},{"name":"kmod-bnxt_en","sw_key_expectedpath":"software:rpm"},{"name":"kmod-bnxt_en","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]},{"key":"7800374","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"en","x_late":"Provides miscellaneous utilities in support of the HPE supported Fibre Channel host bus adapter drivers."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"27844","datemodified":"2021-08-26T07:34:08","file_list":["./etc/.hp_fibreutils","./opt/hp/hp_fibreutils/adapter_info","./opt/hp/hp_fibreutils/adapter_info_nx","./opt/hp/hp_fibreutils/hp_rescan","./opt/hp/hp_fibreutils/lssd","./opt/hp/hp_fibreutils/lssg","./opt/hp/hp_fibreutils/scsi_info","./usr/bin/adapter_info","./usr/bin/adapter_info_nx","./usr/bin/hp_rescan","./usr/bin/lssd","./usr/bin/lssg","./usr/bin/scsi_info","./usr/share/smartupdate/fibreutils/component.xml"],"md5sum":"5b2beb9134f771748b52d4d6b2245f18","name":"fibreutils-4.1-1_rhel.x86_64.rpm","release":"2021-08-26T07:28:11","revision":"0","sha1sum":"663aa962c1844079bc02ed21823d89ceeb21544b","size":"27KB","target_guids":[],"type_of_change":"0","version":"4.1-1"}],"id":{"product":"d95cc03194cc4270817ae00acc36abe2","version":"d407f7ba5c5c4eaaa5df38c0e76a91da"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download fibreutils RPM. <BR>Use rpm -Uvh command to install/upgrade RPM."}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Fibreutils for HPE Storage Fibre Channel Host Bus Adapters for Linux -Red Hat Enterprise Linux (RHEL)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T10:43:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This package supports only&nbsp;Red&nbsp;Hat Enterprise&nbsp;Linux&nbsp;(RHEL) Distros</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"fibreutils","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager（SUM）と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5963880","datemodified":"2021-05-18T01:01:22","file_list":["SignedImageInstaller64.dll","U13_2.90_04_29_2021.signed.flash","cp047887.xml","cpqsetup.exe","cpqsysio64.sys"],"md5sum":"f713489f06dffdd892e3195f3455af29","name":"cp047887.exe","release":"2021-05-18T00:44:06","revision":"0","sha1sum":"e94751a0b0db0a26bc69323f194c68f347803d2d","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021"}],"id":{"product":"536a9a6bb7f448b9be57c310c5a0b4ef","version":"f2b2cc6af72f426cab1b1e50f6a785d3"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant XL230a/XL250a Gen9 (U13) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant XL230a/XL250a Gen9 (U13)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"edition":"hpc","major":"6","minor":"1","name":"Microsoft Windows HPC Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"0","name":"Microsoft Windows Server 2008 x64","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-06T15:32:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","latest_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358.  These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390.  These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"}],"sw_keys":[{"name":"U13","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK0120GFDKE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3132-304746444b45","Version":"HPG1"},{"DeviceName":"VK0240GFDKF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3234-304746444b46","Version":"HPG1"},{"DeviceName":"VK0480GFDKH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3438-304746444b48","Version":"HPG1"},{"DeviceName":"VK0960GFDKK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3936-304746444b4b","Version":"HPG1"},{"DeviceName":"VK1920GFDKL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314b-3932-304746444b4c","Version":"HPG1"},{"DeviceName":"VK3840GFDKN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-334b-3834-304746444b4e","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK0120GFDKE, VK0240GFDKF, VK0480GFDKH, VK0960GFDKK, VK1920GFDKL, and VK3840GFDKN Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：VK0120GFDKE、VK0240GFDKF、VK0480GFDKH、VK0960GFDKK、VK1920GFDKL、およびVK3840GFDKNドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;-&nbsp;VK0120GFDKE, VK0240GFDKF, VK0480GFDKH, VK0960GFDKK, VK1920GFDKL&nbsp;and VK3840GFDKN Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4648223","datemodified":"2021-07-23T08:58:30","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a2d4b5c742-HPG1-10.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-a2d4b5c742-HPG1-10.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a2d4b5c742-HPG1-10.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a2d4b5c742-HPG1-10.1/CP048192.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a2d4b5c742-HPG1-10.1/GPM863G1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-a2d4b5c742-HPG1-10.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a2d4b5c742-HPG1-10.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a2d4b5c742-HPG1-10.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a2d4b5c742-HPG1-10.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048192.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048192.scexe"],"md5sum":"3b807cc9d91c0711b7a2aa181b9a0cd3","name":"firmware-hdd-a2d4b5c742-HPG1-10.1.x86_64.rpm","release":"2021-07-23T08:45:10","revision":"0","sha1sum":"467f27b2ae18d07b42fad1e31797a4f8c0d7dcca","size":"4MB","target_guids":["002340a5-5600-304b-3132-304746444b45","002340a5-5600-304b-3234-304746444b46","002340a5-5600-304b-3438-304746444b48","002340a5-5600-304b-3936-304746444b4b","002340a5-5600-314b-3932-304746444b4c","002340a5-5600-334b-3834-304746444b4e"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"149f4a8ca4634ca1990be51d125b79e4","version":"428d859915c14549ae54a46ac370155c"},"installation":{"command":"CP040295.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK0120GFDKE, VK0240GFDKF, VK0480GFDKH, VK0960GFDKK, VK1920GFDKL and VK3840GFDKN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VK0120GFDKE、VK0240GFDKF、VK0480GFDKH、VK0960GFDKK、VK1920GFDKL、およびVK3840GFDKNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VK0120GFDKE","target_guid":"002340a5-5600-304b-3132-304746444b45","type":"sata"},{"id":"VK1920GFDKL","target_guid":"002340a5-5600-314b-3932-304746444b4c","type":"sata"},{"id":"VK0240GFDKF","target_guid":"002340a5-5600-304b-3234-304746444b46","type":"sata"},{"id":"VK3840GFDKN","target_guid":"002340a5-5600-334b-3834-304746444b4e","type":"sata"},{"id":"VK0480GFDKH","target_guid":"002340a5-5600-304b-3438-304746444b48","type":"sata"},{"id":"VK0960GFDKK","target_guid":"002340a5-5600-304b-3936-304746444b4b","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T10:30:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK0960GFDKK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0120GFDKE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0480GFDKH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK1920GFDKL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK3840GFDKN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0240GFDKF","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWKGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAnAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-3047574b4756","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB004000GWKGV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB004000GWKGV Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"18712859","datemodified":"2021-08-30T19:42:01","file_list":["/CP048319_BUILD_2.data","/CP048319.vmexe","/CP048319.vmexe64","/CP048319.vmfile","/CP048319_VMw.zip","/CP048319.xml","/payload.json","/CP048319_VMw.zip/index.xml","/CP048319_VMw.zip/vendor-index.xml","/CP048319_VMw.zip/metadata.zip","/CP048319_VMw.zip/vib20/CP048319/HPE_bootbank_CP048319_HPG1.2-7.0.0.15843807.vib","/CP048319_VMw.zip/metadata.zip/vendor-index.xml","/CP048319_VMw.zip/metadata.zip/vmware.xml","/CP048319_VMw.zip/metadata.zip/vibs/CP048319-3624375847395312057.xml","/CP048319_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048319_HPG1.2-7.0.0.15843807.xml"],"md5sum":"df8b6b33039322522e7344a24bb5a7c3","name":"CP048319.zip","release":"2021-08-30T19:36:29","revision":"0","sha1sum":"a4103c3963fa64547b34aa055574707954ee3ff6","size":"17MB","target_guids":["4d2340a5-3042-3430-3030-3047574b4756"],"type_of_change":"1","version":"HPG1","vib_list":[{"name":"CP048319","version":"HPG1.2-7.0.0.15843807"}]}],"id":{"product":"cc96bd351eff4426bf37f3da741a7623","version":"19ab963646bf4142be4e0aa9c6b2992c"},"installation":{"command":"CP041493.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB004000GWKGV Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB004000GWKGVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB004000GWKGV","target_guid":"4d2340a5-3042-3430-3030-3047574b4756","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-04T11:12:35","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB004000GWKGV","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCM6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5856-554c38303047","Version":"GPK3"},{"DeviceName":"KCM6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5856-554c31543630","Version":"GPK3"},{"DeviceName":"KCM6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5856-554c33543230","Version":"GPK3"},{"DeviceName":"KCM6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5856-554c36543430","Version":"GPK3"},{"DeviceName":"KCM6XRUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5852-554c39363047","Version":"GPK3"},{"DeviceName":"KCM6XRUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5852-554c31543932","Version":"GPK3"},{"DeviceName":"KCM6XRUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5852-554c33543834","Version":"GPK3"},{"DeviceName":"KCM6XRUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5852-554c37543638","Version":"GPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。KCM6XVUL800G、KCM6XVUL1T60、KCM6XVUL3T20、KCM6XVUL6T40、KCM6XRUL960G、KCM6XRUL1T92、KCM6XRUL3T84、KCM6XRUL7T68"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for&nbsp;VMware ESXi - &nbsp;KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68 Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp; GPK3</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>\n"}],"files":[{"bytes":"18456984","datemodified":"2021-08-30T07:05:32","file_list":["/CP049284_BUILD_1.data","/CP049284.vmexe","/CP049284.vmexe64","/CP049284.vmfile","/CP049284_VMw.zip","/CP049284.xml","/payload.json","/CP049284_VMw.zip/index.xml","/CP049284_VMw.zip/vendor-index.xml","/CP049284_VMw.zip/metadata.zip","/CP049284_VMw.zip/vib20/CP049284/HPE_bootbank_CP049284_GPK3.1-7.0.0.15843807.vib","/CP049284_VMw.zip/metadata.zip/vendor-index.xml","/CP049284_VMw.zip/metadata.zip/vmware.xml","/CP049284_VMw.zip/metadata.zip/vibs/CP049284--4947017558253916959.xml","/CP049284_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049284_GPK3.1-7.0.0.15843807.xml"],"md5sum":"b4a4feb5632456de128b0cc504a64380","name":"CP049284.zip","release":"2021-08-30T07:00:42","revision":"0","sha1sum":"aaec92fcccd6fbc251ec065b3e3aa4e35d0b41af","size":"17MB","target_guids":["002340a5-434b-364d-5856-554c38303047","002340a5-434b-364d-5856-554c31543630","002340a5-434b-364d-5856-554c33543230","002340a5-434b-364d-5856-554c36543430","002340a5-434b-364d-5852-554c39363047","002340a5-434b-364d-5852-554c31543932","002340a5-434b-364d-5852-554c33543834","002340a5-434b-364d-5852-554c37543638"],"type_of_change":"1","version":"GPK3","vib_list":[{"name":"CP049284","version":"GPK3.1-7.0.0.15843807"}]}],"id":{"product":"c101b138be5d4ee79271a6725d6813d4","version":"fd57fa7c34fc4f748b36616a907458ee"},"installation":{"command":"CP042960.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68 Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - KCM6XVUL800G、KCM6XVUL1T60、KCM6XVUL3T20、KCM6XVUL6T40、KCM6XRUL960G、KCM6XRUL1T92、KCM6XRUL3T84、KCM6XRUL7T68ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"KCM6XRUL960G","target_guid":"002340a5-434b-364d-5852-554c39363047","type":"nvme"},{"id":"KCM6XRUL7T68","target_guid":"002340a5-434b-364d-5852-554c37543638","type":"nvme"},{"id":"KCM6XRUL1T92","target_guid":"002340a5-434b-364d-5852-554c31543932","type":"nvme"},{"id":"KCM6XVUL3T20","target_guid":"002340a5-434b-364d-5856-554c33543230","type":"nvme"},{"id":"KCM6XRUL3T84","target_guid":"002340a5-434b-364d-5852-554c33543834","type":"nvme"},{"id":"KCM6XVUL800G","target_guid":"002340a5-434b-364d-5856-554c38303047","type":"nvme"},{"id":"KCM6XVUL6T40","target_guid":"002340a5-434b-364d-5856-554c36543430","type":"nvme"},{"id":"KCM6XVUL1T60","target_guid":"002340a5-434b-364d-5856-554c31543630","type":"nvme"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-16T11:11:22","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This Firmware release address below&nbsp;fixes and additional features:</p>\n\n<ul>\n\t<li>FW Transfer Fix</li>\n\t<li>Drive Failure Fix</li>\n\t<li>Power Loss Protection</li>\n\t<li>FW Download Fix</li>\n\t<li>Reset Fix</li>\n\t<li>Shutdown fix</li>\n\t<li>PCIe Improvement</li>\n\t<li>Random Write Improvement</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"KCM6XVUL6T40","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCM6XRUL1T92","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCM6XVUL800G","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCM6XVUL3T20","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCM6XRUL3T84","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCM6XVUL1T60","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCM6XRUL960G","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCM6XRUL7T68","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GWTFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG07abHPG7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304757544645","Version":"HPG7"},{"DeviceName":"MB014000GWTFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG07abHPG7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304757544646","Version":"HPG7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB012000GWTFE and MB014000GWTFF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB012000GWTFE and MB014000GWTFF Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG7</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG6</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG6<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4899291","datemodified":"2021-07-23T07:20:23","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b78255e146-HPG7-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-b78255e146-HPG7-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b78255e146-HPG7-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b78255e146-HPG7-3.1/CP048138.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b78255e146-HPG7-3.1/TAMG07abHPG7.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-b78255e146-HPG7-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b78255e146-HPG7-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b78255e146-HPG7-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b78255e146-HPG7-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048138.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048138.scexe"],"md5sum":"1d72c47b26f6da4a002c920bc352a04a","name":"firmware-hdd-b78255e146-HPG7-3.1.x86_64.rpm","release":"2021-07-23T07:08:11","revision":"0","sha1sum":"4b6111549d4231150160d12d4c580bed3f83e00d","size":"4MB","target_guids":["4d2340a5-3042-3231-3030-304757544645","4d2340a5-3042-3431-3030-304757544646"],"type_of_change":"1","version":"HPG7"}],"id":{"product":"03a1d5d1c9c84f2b9c715674a729ac00","version":"ec43d5dfea664a0aab8c044594f7bc4a"},"installation":{"command":"CP042460.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB012000GWTFE and MB014000GWTFF Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB012000GWTFEおよびMB014000GWTFFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB014000GWTFF","target_guid":"4d2340a5-3042-3431-3030-304757544646","type":"sata"},{"id":"MB012000GWTFE","target_guid":"4d2340a5-3042-3231-3030-304757544645","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-26T12:09:19","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB012000GWTFE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB014000GWTFF","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB1000GDUNU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3142-3030-304744554e55","Version":"HPG4"},{"DeviceName":"MB2000GDUNV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304744554e56","Version":"HPG4"},{"DeviceName":"MB3000GDUPA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304744555041","Version":"HPG4"},{"DeviceName":"MB4000GDUPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304744555042","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB1000GDUNU, MB2000GDUNV, MB3000GDUPA, and MB4000GDUPB Drives "},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MB1000GDUNU, MB2000GDUNV, MB3000GDUPA, およびMB4000GDUPBドライブ "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;-&nbsp;MB1000GDUNU, MB2000GDUNV, MB3000GDUPA&nbsp;and MB4000GDUPB Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br />\n<br />\n<strong>Enhancements/New Features&nbsp;:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<ul>\n\t<li>Firmware cannot be downgraded to HPG3 after updating to HPG4.</li>\n</ul>\n"}],"files":[{"bytes":"5246804","datemodified":"2021-07-23T06:09:11","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-3ab4c70e64-HPG4-10.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-3ab4c70e64-HPG4-10.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-3ab4c70e64-HPG4-10.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3ab4c70e64-HPG4-10.1/CP048145.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-3ab4c70e64-HPG4-10.1/TAHARRG4.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-3ab4c70e64-HPG4-10.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3ab4c70e64-HPG4-10.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-3ab4c70e64-HPG4-10.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-3ab4c70e64-HPG4-10.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048145.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048145.scexe"],"md5sum":"63ea3f554703f861b12889e41bd31a80","name":"firmware-hdd-3ab4c70e64-HPG4-10.1.x86_64.rpm","release":"2021-07-23T05:54:06","revision":"0","sha1sum":"158e214d5fe182f118ad7e55309d1da2f2cdef1a","size":"5MB","target_guids":["002340a5-4d00-3142-3030-304744554e55","002340a5-4d00-3242-3030-304744554e56","002340a5-4d00-3342-3030-304744555041","002340a5-4d00-3442-3030-304744555042"],"type_of_change":"1","version":"HPG4"}],"id":{"product":"be75bc90ea544ceea229c5a0eeef825c","version":"3aa57d9599ac445ea7ec7ec936ad4508"},"installation":{"command":"CP040288.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB1000GDUNU, MB2000GDUNV, MB3000GDUPA and MB4000GDUPB Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB1000GDUNU、MB2000GDUNV、MB3000GDUPA、および MB4000GDUPB ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB1000GDUNU","target_guid":"002340a5-4d00-3142-3030-304744554e55","type":"sata"},{"id":"MB2000GDUNV","target_guid":"002340a5-4d00-3242-3030-304744554e56","type":"sata"},{"id":"MB3000GDUPA","target_guid":"002340a5-4d00-3342-3030-304744555041","type":"sata"},{"id":"MB4000GDUPB","target_guid":"002340a5-4d00-3442-3030-304744555042","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-26T18:32:19","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB2000GDUNV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB3000GDUPA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB4000GDUPB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB1000GDUNU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWUDB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEBHssseFD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57554442","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB014000JWUDB"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB014000JWUDB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB014000JWUDB Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"6202885","datemodified":"2021-07-23T06:02:33","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD3-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD3-2.1/CP048144.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD3-2.1/HLEBHssseFD3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD3-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048144.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048144.scexe"],"md5sum":"de04781928d9d50a155dfca25080738d","name":"firmware-hdd-cfd7436fcc-HPD3-2.1.x86_64.rpm","release":"2021-07-23T05:50:08","revision":"0","sha1sum":"cfaa54b806b30102e2c1ef218308dc4366e2aa6a","size":"5MB","target_guids":["4d2340a5-3042-3431-3030-304a57554442"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"6cc89934ad1740b582b096e05315f04a","version":"83d6fc0e42d84131b8383a7f30d23702"},"installation":{"command":"CP041518.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB014000JWUDB Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB014000JWUDBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB014000JWUDB","target_guid":"4d2340a5-3042-3431-3030-304a57554442","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-26T18:25:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to &ldquo;HPE&rdquo;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB014000JWUDB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG0300FCSPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SED2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3330-304643535048","Version":"HPD2"},{"DeviceName":"EG0450FCSPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SED2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3435-30464353504b","Version":"HPD2"},{"DeviceName":"EG0600FCSPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SED2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3630-30464353504c","Version":"HPD2"},{"DeviceName":"EG0900FCSPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SED2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3930-30464353504e","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG0300FCSPH, EG0450FCSPK, EG0600FCSPL and EG0900FCSPN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong></p>\n\n<p><br />\n&nbsp; &nbsp; &nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - EG0300FCSPH, EG0450FCSPK, EG0600FCSPL&nbsp;and EG0900FCSPN Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp; </strong>None</p>\n"}],"files":[{"bytes":"2902480","datemodified":"2021-07-24T07:03:24","file_list":["cp048481.xml","cpqsetup.exe","payload.json","setup.dll","TA13SED2.REL"],"md5sum":"843c798200406733b11d94e60e836c63","name":"cp048481.exe","release":"2021-07-24T06:55:11","revision":"0","sha1sum":"e343d0e3e5619d3cb1dd9f965e95467dba972e75","size":"2MB","target_guids":["002340a5-4500-3047-3330-304643535048","002340a5-4500-3047-3435-30464353504b","002340a5-4500-3047-3630-30464353504c","002340a5-4500-3047-3930-30464353504e"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"e3b32b83ce544644bc4408de465e0c11","version":"a6d0f8a37cda4fe8b09f477d1568e8f3"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG0300FCSPH, EG0450FCSPK, EG0600FCSPL and EG0900FCSPN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows(x64)- EG0300FCSPH、EG0450FCSPK、EG0600FCSPL、およびEG0900FCSPNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG0300FCSPH","target_guid":"002340a5-4500-3047-3330-304643535048","type":"sas"},{"id":"EG0450FCSPK","target_guid":"002340a5-4500-3047-3435-30464353504b","type":"sas"},{"id":"EG0600FCSPL","target_guid":"002340a5-4500-3047-3630-30464353504c","type":"sas"},{"id":"EG0900FCSPN","target_guid":"002340a5-4500-3047-3930-30464353504e","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-14T03:45:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG0450FCSPK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0300FCSPH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0900FCSPN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0600FCSPL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"tw","x_late":"系統管理首頁針對單一伺服器管理提供一個統整且緊密的整合管理功能，包括效能、故障、安全性、診斷、組態及軟體變更管理。"},{"lang":"en","x_late":"The System Management Homepage provides a consolidated view for single server management highlighting tightly integrated management functionalities including performance, fault, security, diagnostic, configuration, and software change management."},{"lang":"ko","x_late":"시스템 관리 홈 페이지는 성능, 고장, 진단, 구성 및 소프트웨어 변경 관리를 포함한 통합 관리 기능을 강조한 단일 서버 관리용 통합 뷰를 제공합니다."},{"lang":"cn","x_late":"通过 System Management Homepage，可以统一查看单个服务器管理，特别是综合管理功能，包括性能、故障、安全性、诊断、配置及软件更改管理。"},{"lang":"ja","x_late":"System Management Homepageは、パフォーマンス、障害、セキュリティ、診断、コンフィギュレーション、およびソフトウェアの変更管理を含む統合された管理機能をハイライトする、シングル サーバー管理のための集約した画面を提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[{"lang":"en","x_late":"<p>As per SMH EOL terms, future patch releases will continue to provide fixes for security vulnerabilities &amp; might not provide support to any new OS or Browser.</p>\n"},{"lang":"ja","x_late":"<p>SMH EOLの利用規約によれば、将来のパッチリリースは安全上の脆弱性の解決策の提供を続けます、&新しい OSまたはブラウザーのサポートは提供しません。</p>\n"}],"files":[{"bytes":"19732832","datemodified":"2020-07-16T06:58:47","file_list":["0x0409.ini","0x0411.ini","0x0804.ini","cp043048.xml","cpqinstall.bat","cp_data.xml","data1.cab","data1.hdr","data2.cab","elmsetup.dll","hpsmh.frm","hpsmh.frm.ja","hpsmh_config_en.xml","hpsmh_config_ja.xml","hpsmh_config_zh.xml","ISSetup.dll","layout.bin","setup.exe","setup.ini","setup.inx","setup.iss","smhsetup.exe"],"md5sum":"668b55c4d241ff4c7f645155606fd062","name":"cp043048.exe","release":"2020-07-16T06:55:05","revision":"0","sha1sum":"003db6d7816f522289ef1bf485873855e4b6f253","size":"18MB","target_guids":[],"type_of_change":"1","version":"7.6.6.2"}],"id":{"product":"efbcca27fdf947149d2bf0ed9f4fb6db","version":"24955e8cb0a24fb2acdd537b545f5af0"},"installation":{"command":"cpqinstall.bat","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<ol>\n <li>\n  Download the Smart Component (cpxxxxxx.exe) file to a local directory on the server where you want to install the software.</li>\n <li>\n  Change to the directory.</li>\n <li>\n  Run the .exe file by double-clicking it. A dialog box will display.</li>\n <li>\n  Click the &lsquo;Install&rsquo; button to install the SMH.</li>\n</ol>\n"},{"lang":"ja","x_late":"<ol>\n <li>\n  ソフトウェアをインストールするサーバーのローカルディレクトリにSmartコンポーネント（cpxxxxxx.exe)）ファイルをダウンロードします。</li>\n <li>\n  そのディレクトリに移動します。</li>\n <li>\n  .exeファイルをダブルクリックして実行します。 ダイアログボックスが表示されます。</li>\n <li>\n  [インストール]ボタンをクリックしてSMHをインストールします。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Windows x64 的 HPE System Management Homepage"},{"lang":"en","x_late":"HPE System Management Homepage for Windows x64"},{"lang":"ko","x_late":"Windows x64용 HPE System Management Homepage"},{"lang":"cn","x_late":"用于 Windows x64 的 HPE System Management Homepage"}],"prerequisites":{"required_diskspace":{"size_kb":"70000"},"supported_devices":[{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"Microsoft Windows Server 2008 x64","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"edition":"sbs","major":"6","minor":"0","name":"Microsoft Windows Server 2008 Small Business","platform":"nt_x86-64","sr":"OEM"},{"edition":"ebs","major":"6","minor":"0","name":"Microsoft Windows Server 2008 Essential Business","platform":"nt_x86-64","sr":"OEM"},{"edition":"fndtn","major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2 Foundation Edition","platform":"nt_x86-64","sr":"OEM"},{"edition":"sbs","major":"6","minor":"1","name":"Microsoft Windows Small Business Server 2011 Standard and Essentials","platform":"nt_x86-64","sr":"OEM"},{"edition":"R2","major":"6","minor":"1","name":"Microsoft Windows Storage Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"0","name":"Microsoft Windows Storage Server 2008 x64 Editions","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-03-03T06:43:35","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><br />\nUpdated the following components:</p>\n\n<ul>\n\t<li>PHP to version 5.6.30</li>\n\t<li>Zlib to version 1.2.11</li>\n\t<li>Libxslt to version 1.1.32</li>\n\t<li>PCRE to version 8.41</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated the following components:</p>\n\n<ul>\n\t<li>&nbsp;&nbsp;&nbsp; Apache to version 2.4.41</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P74","value":"HP ProLiant SL140s Gen8 Server (private)"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A29","value":"HP ProLiant DL585 Gen8 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 v2 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P78","value":"HP ProLiant ML310e Gen8 v2 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"P83","value":"HP ProLiant SL210t Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"},{"key":"","value":"HPE System Management Homepage Software"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"}],"sw_keys":[{"name":"hpsmhd.exe","sw_key_expectedpath":"%systemdrive%\\hp\\hpsmh\\bin"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWUDA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEBHasseFG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304757554441","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB014000GWUDA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB014000GWUDA Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4385912","datemodified":"2021-07-23T10:13:56","file_list":["cp048545.xml","cpqsetup.exe","HLEBHasseFG2.rel","payload.json","setup.dll"],"md5sum":"4d6c032e129fd8a1420705d0deab8def","name":"cp048545.exe","release":"2021-07-23T10:06:11","revision":"0","sha1sum":"950c260d6604848e732b1e0d25e97d29db06c9b1","size":"4MB","target_guids":["4d2340a5-3042-3431-3030-304757554441"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"074cd65cf284444dbd64a63e5f809ff6","version":"eff018269bb044e38e8b4a37428b7135"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB014000GWUDA Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB014000GWUDAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB014000GWUDA","target_guid":"4d2340a5-3042-3431-3030-304757554441","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T12:27:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB014000GWUDA","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK0240GEPQN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM853G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3234-30474550514e","Version":"HPG1"},{"DeviceName":"VK0480GEPQP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM853G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3438-304745505150","Version":"HPG1"},{"DeviceName":"VK0960GEPQQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM853G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3936-304745505151","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK0240GEPQN, VK0480GEPQP and VK0960GEPQQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK0240GEPQN, VK0480GEPQP&nbsp;and VK0960GEPQQ Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"16015753","datemodified":"2021-08-27T10:47:39","file_list":["/CP048413_BUILD_4.data","/CP048413.vmexe","/CP048413.vmexe64","/CP048413.vmfile","/CP048413_VMw.zip","/CP048413.xml","/payload.json","/CP048413_VMw.zip/index.xml","/CP048413_VMw.zip/vendor-index.xml","/CP048413_VMw.zip/metadata.zip","/CP048413_VMw.zip/vib20/CP048413/HPE_bootbank_CP048413_HPG1.4-7.0.0.15843807.vib","/CP048413_VMw.zip/metadata.zip/vendor-index.xml","/CP048413_VMw.zip/metadata.zip/vmware.xml","/CP048413_VMw.zip/metadata.zip/vibs/CP048413-7453443161214509018.xml","/CP048413_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048413_HPG1.4-7.0.0.15843807.xml"],"md5sum":"5a0382d3550579c02ccc04ea6a0def3f","name":"CP048413.zip","release":"2021-08-27T10:42:03","revision":"0","sha1sum":"c92c7bcd41f51f1a9798f9835ee0d40eb01fcaa1","size":"15MB","target_guids":["002340a5-5600-304b-3234-30474550514e","002340a5-5600-304b-3438-304745505150","002340a5-5600-304b-3936-304745505151"],"type_of_change":"1","version":"HPG1","vib_list":[{"name":"CP048413","version":"HPG1.4-7.0.0.15843807"}]}],"id":{"product":"c565c3f6bc0f4964b8b59efe8bfdfdea","version":"5aaa7432af0145b588834dd37133a1f6"},"installation":{"command":"CP040528.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK0240GEPQN, VK0480GEPQP and VK0960GEPQQ Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VK0240GEPQN、VK0480GEPQP、およびVK0960GEPQQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VK0240GEPQN","target_guid":"002340a5-5600-304b-3234-30474550514e","type":"sata"},{"id":"VK0480GEPQP","target_guid":"002340a5-5600-304b-3438-304745505150","type":"sata"},{"id":"VK0960GEPQQ","target_guid":"002340a5-5600-304b-3936-304745505151","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T08:24:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK0960GEPQQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0240GEPQN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0480GEPQP","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000JFEML","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a46454d4c","Version":"HPD6"},{"DeviceName":"MB4000JFEMN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a46454d4e","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB2000JFEML and MB4000JFEMN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB2000JFEML and MB4000JFEMN Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.&nbsp; This issue was found during supplier ongoing reliability testing.</p>\n\t</li>\n\t<li>\n\t<p>The firmware also includes emergency power off improvements.</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"17443341","datemodified":"2021-08-26T19:15:44","file_list":["/CP048361_BUILD_2.data","/CP048361.vmexe","/CP048361.vmexe64","/CP048361.vmfile","/CP048361_VMw.zip","/CP048361.xml","/payload.json","/CP048361_VMw.zip/index.xml","/CP048361_VMw.zip/vendor-index.xml","/CP048361_VMw.zip/metadata.zip","/CP048361_VMw.zip/vib20/CP048361/HPE_bootbank_CP048361_HPD6.2-7.0.0.15843807.vib","/CP048361_VMw.zip/metadata.zip/vendor-index.xml","/CP048361_VMw.zip/metadata.zip/vmware.xml","/CP048361_VMw.zip/metadata.zip/vibs/CP048361--6810381694176016378.xml","/CP048361_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048361_HPD6.2-7.0.0.15843807.xml"],"md5sum":"9217af76bb0c516c24eebea4d1603463","name":"CP048361.zip","release":"2021-08-26T19:10:28","revision":"0","sha1sum":"ec7aa8ed838288e80861670aaa8f5a356d0199cf","size":"16MB","target_guids":["002340a5-4d00-3242-3030-304a46454d4c","002340a5-4d00-3442-3030-304a46454d4e"],"type_of_change":"2","version":"HPD6","vib_list":[{"name":"CP048361","version":"HPD6.2-7.0.0.15843807"}]}],"id":{"product":"193fefc836ff47bc98df145955f3145a","version":"7ba50602247a440da4bf7da81032d5b0"},"installation":{"command":"CP040640.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - MB2000JFEML and MB4000JFEMN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - MB2000JFEMLおよびMB4000JFEMNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB4000JFEMN","target_guid":"002340a5-4d00-3442-3030-304a46454d4e","type":"sas"},{"id":"MB2000JFEML","target_guid":"002340a5-4d00-3242-3030-304a46454d4c","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-07T11:54:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was found during supplier ongoing reliability testing.</li>\n\t<li>The firmware also includes emergency power off improvements.</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was found during supplier ongoing reliability testing.</li>\n\t<li>The firmware also includes emergency power off improvements.</li>\n</ul>","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JFEMN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB2000JFEML","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"nmlx5 is the low level driver implementation for the ConnectX®-4 and ConnectX®-5 adapters for VMware ESXi 6.5 Mellanox Ethernet Adapters."},{"lang":"ja","x_late":"nmlx5は、VMware ESXi 6.5 Mellanoxイーサーネットアダプター用ConnectX®-4およびConnectX®-5アダプターの低レベルドライバー実装です。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"676474","datemodified":"2021-08-27T13:36:04","file_list":["/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-17702356.zip","/cp047577.xml","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-17702356.zip/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-offline_bundle-17702356.zip","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-17702356.zip/doc/README.txt","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-17702356.zip/doc/release_note_nmlx5-rdma_4.16.71.1-1OEM.650.0.0.4598673.pdf","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-17702356.zip/doc/release_note_nmlx5-core_4.16.71.1-1OEM.650.0.0.4598673.pdf","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-17702356.zip/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-offline_bundle-17702356.zip/index.xml","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-17702356.zip/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-offline_bundle-17702356.zip/vendor-index.xml","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-17702356.zip/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-offline_bundle-17702356.zip/metadata.zip","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-17702356.zip/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-offline_bundle-17702356.zip/vib20/nmlx5-core/MEL_bootbank_nmlx5-core_4.16.71.1-1OEM.650.0.0.4598673.vib","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-17702356.zip/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-offline_bundle-17702356.zip/vib20/nmlx5-rdma/MEL_bootbank_nmlx5-rdma_4.16.71.1-1OEM.650.0.0.4598673.vib","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-17702356.zip/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-offline_bundle-17702356.zip/metadata.zip/vendor-index.xml","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-17702356.zip/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-offline_bundle-17702356.zip/metadata.zip/vmware.xml","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-17702356.zip/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-offline_bundle-17702356.zip/metadata.zip/vibs/nmlx5-core--1864763229.xml","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-17702356.zip/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-offline_bundle-17702356.zip/metadata.zip/vibs/nmlx5-rdma--1854117972.xml","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-17702356.zip/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-offline_bundle-17702356.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-nmlx5_rdma-4.16.71.1.xml","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-17702356.zip/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-offline_bundle-17702356.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-nmlx5_core-4.16.71.1.xml"],"md5sum":"7420fb96acf6e39359de8c309a29386e","name":"cp047577.zip","release":"2021-08-27T13:34:52","revision":"0","sha1sum":"6d5355682eee504f348308c26f0884b0b4271ce2","size":"660KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecdebb2a48","20a6e8e4-bf33-4c71-a6bf-d9ec41bd2821"],"type_of_change":"1","version":"2021.04.15","vib_list":[{"name":"nmlx5-rdma","version":"4.16.71.1-1OEM.650.0.0.4598673"},{"name":"nmlx5-core","version":"4.16.71.1-1OEM.650.0.0.4598673"}]}],"id":{"product":"b0057e5ba3444c3eb76eb15c0d0d8adc","version":"95e732b2cda44d06b1a58f1b60313950"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Remote Online:&nbsp;</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the HPE USB Key Creator Utility.&nbsp;</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux .</li>\n\t<li>cd /SPP20xxxxx/ and launch SUM&nbsp;(launch_sum.bat for Windows and ./launch_sum.sh for Linux).</li>\n\t<li>Select &quot;Baseline Library&quot; and wait for the Baseline inventory to complete.</li>\n\t<li>Select &quot;Nodes&quot; from the &quot;Smart Update Manager x.x.x&quot; drop down.</li>\n\t<li>Click, &quot;Add Node&quot;.\n\t<ul>\n\t\t<li>If adding a Gen9 server,\n\t\t<ul>\n\t\t\t<li>Provide IP address of the ESXi host.</li>\n\t\t\t<li>Enter&nbsp;the ESXi host credentials (root or administrator username and password)&nbsp;</li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>If adding a Gen10 and above server,\n\t\t<ul>\n\t\t\t<li>Provide iLO IP address of the ESXi host server.</li>\n\t\t\t<li>Enter the iLO credentials of the ESXi host server.</li>\n\t\t</ul>\n\t\t</li>\n\t</ul>\n\t</li>\n\t<li>Follow&nbsp;Smart Update Manager Steps and complete the driver update.&nbsp;</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware VUM or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>リモートオンライン: </strong></p>\n\n<ol>\n\t<li>HPE USB Key Creator Utilityを使用して、SPPをUSBキーにコピーします。 </li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。</li>\n\t<li>cd /SPP20xxxxx およびSUMを起動します。（Windowsの場合はlaunch_sum.bat、Linuxの場合は./launch_sum.sh）</li>\n\t<li>\"ベースラインライブラリ\"を選択し、ベースラインインベントリが完了するのを待ちます。</li>\n\t<li>\"Smart Update Manager x.x.x\"ドロップダウンから\"ノード\"を選択します。</li>\n\t<li>\"ノードの追加\"をクリックします。\n\t<ul>\n\t\t<li>Gen9サーバーを追加する場合、\n\t\t<ul>\n\t\t\t<li>ESXiホストのIPアドレスを提供します。</li>\n\t\t\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します </li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>Gen10以降のサーバーを追加する場合、\n\t\t<ul>\n\t\t\t<li>ESXiホストサーバーのiLO IPアドレスを提供します。</li>\n\t\t\t<li>ESXiホストサーバーのiLO認証情報を入力します。</li>\n\t\t</ul>\n\t\t</li>\n\t</ul>\n\t</li>\n\t<li>Smart Update Managerの指示に従い、ドライバーのアップデートを完了します。 </li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li>\n\t<li>オフラインバンドルをインストールするために、VMware VUMまたはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"nmlx5_en Driver Component for VMware 6.5"},{"lang":"ja","x_late":"nmlx5_enドライバーコンポーネント for VMware 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"032D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-10171590032d","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30047","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"0221","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101315900221","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-16T12:06:43","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Changes and New Features in smart component version 2020.11.11:</strong></p>\n\n<ul>\n\t<li>Added support for the following adapters:\n\t<ul>\n\t\t<li>HPE Ethernet 200Gb 1-Port QSFP56 MCX623105AS-VDAT Adapter (HPE Part Number: P10180-B21)</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>New features and changes in version 4.16.70.1:</strong></p>\n\n<ul>\n\t<li>An event will be sent to notify the administrator if the power required by the network adapter is higher than that available on the PCIe slot.</li>\n\t<li>Support for trusting Differentiated Services Code Point (DSCP) and setting default value for RoCE traffic.</li>\n\t<li>A&nbsp;new counter that enables the user to query per Virtual Function counters.</li>\n\t<li>RX out-of-buffer counter to indicate any lack of software receive buffers.</li>\n\t<li>Module parameter to enforce specific RoCE version.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version&nbsp;in 4.16.70.1:</strong></p>\n\n<ul>\n\t<li>\n\t<p>The &quot;esxcli network sriovnic vf stats&quot; command was not supported. When running this command on a vmknic, a failure message was displayed.</p>\n\t</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Changes and New Features in smart component version 2021.04.15:</strong></p>\n\n<ul>\n\t<li>Added support for the following adapters:\n\t<ul>\n\t\t<li>HPE Ethernet 200Gb 1-Port QSFP56 MCX623105AS-VDAT Adapter (HPE Part Number: P10180-B21)</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>New features and changes in version 4.16.71.1:</strong></p>\n\n<ul>\n\t<li>An event will be sent to notify the administrator if the power required by the network adapter is higher than that available on the PCIe slot.</li>\n\t<li>Support for trusting Differentiated Services Code Point (DSCP) and setting default value for RoCE traffic.</li>\n\t<li>A&nbsp;new counter that enables the user to query per Virtual Function counters.</li>\n\t<li>RX out-of-buffer counter to indicate any lack of software receive buffers.</li>\n\t<li>Module parameter to enforce specific RoCE version.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version&nbsp;in 4.16.71.1:</strong></p>\n\n<ul>\n\t<li>\n\t<p>The &quot;esxcli network sriovnic vf stats&quot; command was not supported. When running this command on a vmknic, a failure message was displayed.</p>\n\t</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"","value":"HPE Apollo kl20 Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"","value":"HPE Apollo am35 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo pc40 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"","value":"HPE Apollo sx40 Server"}],"sw_keys":[{"name":"nmlx5-rdma:4.16.71.1-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"},{"name":"nmlx5-core:4.16.71.1-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Blade Intel ixgben Adapters running under VMware vSphere 6.7."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;1.7.20.</p>\n"}],"files":[{"bytes":"352850","datemodified":"2019-10-24T14:38:10","file_list":["/cp039953.xml","/VMW-ESX-6.7.0-ixgben-1.7.20-14162871.zip","/VMW-ESX-6.7.0-ixgben-1.7.20-14162871.zip/VMW-ESX-6.7.0-ixgben-1.7.20-offline_bundle-14162871.zip","/VMW-ESX-6.7.0-ixgben-1.7.20-14162871.zip/ixgben-1.7.20-1OEM.670.0.0.8169922.x86_64.vib","/VMW-ESX-6.7.0-ixgben-1.7.20-14162871.zip/doc/README.txt","/VMW-ESX-6.7.0-ixgben-1.7.20-14162871.zip/doc/release_note_ixgben_1.7.20-1OEM.670.0.0.8169922.txt","/VMW-ESX-6.7.0-ixgben-1.7.20-14162871.zip/VMW-ESX-6.7.0-ixgben-1.7.20-offline_bundle-14162871.zip/index.xml","/VMW-ESX-6.7.0-ixgben-1.7.20-14162871.zip/VMW-ESX-6.7.0-ixgben-1.7.20-offline_bundle-14162871.zip/vendor-index.xml","/VMW-ESX-6.7.0-ixgben-1.7.20-14162871.zip/VMW-ESX-6.7.0-ixgben-1.7.20-offline_bundle-14162871.zip/metadata.zip","/VMW-ESX-6.7.0-ixgben-1.7.20-14162871.zip/VMW-ESX-6.7.0-ixgben-1.7.20-offline_bundle-14162871.zip/vib20/ixgben/INT_bootbank_ixgben_1.7.20-1OEM.670.0.0.8169922.vib","/VMW-ESX-6.7.0-ixgben-1.7.20-14162871.zip/VMW-ESX-6.7.0-ixgben-1.7.20-offline_bundle-14162871.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.7.0-ixgben-1.7.20-14162871.zip/VMW-ESX-6.7.0-ixgben-1.7.20-offline_bundle-14162871.zip/metadata.zip/vmware.xml","/VMW-ESX-6.7.0-ixgben-1.7.20-14162871.zip/VMW-ESX-6.7.0-ixgben-1.7.20-offline_bundle-14162871.zip/metadata.zip/bulletins/VMW-ESX-6.7.0-ixgben-1.7.20.xml","/VMW-ESX-6.7.0-ixgben-1.7.20-14162871.zip/VMW-ESX-6.7.0-ixgben-1.7.20-offline_bundle-14162871.zip/metadata.zip/vibs/ixgben--3021017326292478617.xml"],"md5sum":"099e4c8aedd09d6edb0695b165f8146e","name":"cp039953.zip","release":"2019-10-24T19:38:03","revision":"0","sha1sum":"47d8eb5cc55dc929fa1631174e39de794bf23174","size":"344KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4a9c3d5c"],"type_of_change":"0","version":"2019.12.20","vib_list":[{"name":"ixgben","version":"1.7.20-1OEM.670.0.0.8169922"}]}],"id":{"product":"64cacd5223744f8db526479e2a86e773","version":"1c671ff8414c4d91818629790cf7a0f0"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Intel ixgben Driver for VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c18d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-11-08T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release.</p>\n","curr_fixes_x_late":"<p>This product corrects a&nbsp;recursion termination condition so that recursion&nbsp;correctly ends in the case of&nbsp; PCIe link down.</p>\n\n<p>This product addresses an issue where the ixgben driver has high CPU overhead&nbsp;when an SFP+ module is absent.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"ixgben:1.7.20-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6244373","datemodified":"2021-05-18T02:48:29","file_list":["./usr/lib/i386-linux-gnu/firmware-system-p86-2.90_2021_04_29-1.1","./usr/lib/i386-linux-gnu/firmware-system-p86-2.90_2021_04_29-1.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-system-p86-2.90_2021_04_29-1.1/.setup","./usr/lib/i386-linux-gnu/firmware-system-p86-2.90_2021_04_29-1.1/CP047859.xml","./usr/lib/i386-linux-gnu/firmware-system-p86-2.90_2021_04_29-1.1/P86_2.90_04_29_2021.signed.flash","./usr/lib/i386-linux-gnu/firmware-system-p86-2.90_2021_04_29-1.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-system-p86-2.90_2021_04_29-1.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP047859.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP047859.scexe"],"md5sum":"de94e9f7f6b2d1e13a80704aff0b33d9","name":"firmware-system-p86-2.90_2021_04_29-1.1.i386.rpm","release":"2021-05-18T02:38:23","revision":"0","sha1sum":"adcb6c126d178da4664b63c8233164c54625bf13","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021"}],"id":{"product":"74e7399cb8c44299934a1057e39251e9","version":"c4bc6d69a80d463591c9441ea36716cc"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HPE ProLiant Agentless Management Service (<strong>AMS</strong>) and HPE SNMP Agents (<strong>SNMP Agents</strong>) are both running.&nbsp; HPE does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager 8.0.0 or later, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、iLOとの通信ができない場合に失敗します。  これは、HPE ProLiant Agentless Management Service (<strong>AMS</strong>)およびHPE SNMPエージェント(<strong>SNMP Agents</strong>)の両方が実行されているときに発生します。  HPEでは、AMSおよびSNMPエージェントを同時に実行させないことを推奨します。  「iLO device not found」エラーが発生した場合、AMSまたはSNMPエージェントを停止させて、再度フラッシュコンポーネントを実行します。<br />\n<br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上のSmart Update Manager 8.0.0以降を使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant DL120 Gen9 (P86) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Linux - HPE ProLiant DL120 Gen9（P86）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Oracle Linux 6 (AMD64/EMT64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Oracle Linux 7","platform":"Oracle Enterprise Linux","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-05T03:59:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"}],"sw_keys":[{"name":"P86","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300032","languages":[{"lang":"fr","x_late":"Pilote - Gestion du système"},{"lang":"en","x_late":"Driver - System Management"},{"lang":"cn","x_late":"驱动程序 - 系统管理"},{"lang":"tw","x_late":"驅動程式 ─ 系統管理"},{"lang":"de","x_late":"Treiber - Systemverwaltung"},{"lang":"ko","x_late":"드라이버 - 시스템 관리"},{"lang":"it","x_late":"Driver - Gestione sistema"},{"lang":"ja","x_late":"ドライバ - システム マネジメント"},{"lang":"es","x_late":"Controlador - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The iLO 4 Management Controller Driver Package provides system management support, including monitoring of server components, event logging, and support for the Insight Management Agents and WBEM Providers."},{"lang":"ja","x_late":"iLO 4マネジメントコントローラードライバーパッケージは、サーバーコンポーネントの監視、イベントログなどのシステム管理のサポート、およびInsightマネジメントエージェントとWBEMプロバイダーのサポートを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[],"files":[{"bytes":"1102112","datemodified":"2018-10-02T17:36:58","file_list":["cp035109.xml","cpqsetup.exe","depcheck.dll","hpqilo3core.cab","hpqilo3core.msi","hpqilo3service.cab","hpqilo3service.msi","install.xml","multisetup.dll"],"md5sum":"14c02da58c33c245c2feae3efcd44979","name":"cp035109.exe","release":"2018-10-25T00:00:00","revision":"1","sha1sum":"5a74bd3dd7536b2cdf2a82d0704394b99e013c1f","size":"1MB","target_guids":[],"type_of_change":"0","version":"4.0.0.0"}],"id":{"product":"c55c1821244f45499ef3e6eefbb25ee1","version":"ac37e1a512c0461e9e95e70d3cf6c554"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 3/4 Channel Interface Driver for Windows X64","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 3/4 Channel Interface Driver for Windows X64"}]}]}]},"installation_notes":[{"lang":"tw","x_late":"將智慧型元件放在臨時目錄中，按兩下執行。<p>選擇「Install（安裝）」開始解壓縮至硬碟上的一個臨時位置。   <p>按一下「Install（安裝）」繼續進行驅動程式的安裝。"},{"lang":"en","x_late":"Place the Smart Component in a temporary directory, then double-click it to run.<p>Select \"Install\" to start extracting to a temporary location on the hard drive.   <p>Click the \"Install\" button to perform the driver installation."},{"lang":"ko","x_late":"스마트 구성 요소를 임시 디렉터리에 저장하고 이를 더블 클릭하여 실행합니다.<p>\"설치\"를 선택하여 하드 드라이브의 임시 디렉터리에 압축을 풉니다.   <p>\"설치\" 버튼을 클릭하여 드라이버 설치 작업을 시작합니다."},{"lang":"cn","x_late":"将智能组件置于临时目录中，然后双击运行。<p>选择“安装”，开始提取至硬盘的临时位置。   <p>点击“安装”按钮继续执行驱动程序安装。"},{"lang":"ja","x_late":"Smartコンポーネントをテンポラリ ディレクトリにコピーし、ダブルクリックして実行します。<p>インストールを選択して、ハードディスクのテンポラリ ディレクトリに解凍します。   <p>インストール ボタンをクリックしてドライバー インストールを実行します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"iLO 4 Management Controller Driver Package for Windows Server 2012 and Server 2012 R2"},{"lang":"ja","x_late":"iLO 4マネジメントコントローラードライバーパッケージfor Windows Server 2012および2012 R2"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"1979","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3302","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows 8.1 (64-bit)","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-02-03T20:09:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Aligned system and operating system support with the production Service Pack for ProLiant.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Aligned system and operating system support with the production Service Pack for ProLiant:</p>\n\n<ul>\n\t<li>Removed support for Windows Server 2008 and Windows Server 2008 R2.</li>\n\t<li>Removed support for iLO 3.</li>\n\t<li>Removed support for HP ProLiant G7 and HP ProLiant Gen8 systems.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"}],"sw_keys":[{"name":"ProLiantMonitor.exe","sw_key_expectedpath":"%ProgramFiles%\\Hewlett-Packard\\iLO 3\\service"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager（SUM）と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5662776","datemodified":"2021-06-02T02:15:20","file_list":["SignedImageInstaller64.dll","U22_3.00_04_01_2021.signed.flash","cp047376.xml","cpqsetup.exe","cpqsysio64.sys"],"md5sum":"795301bc3ff231b8af8c28b7cd7a7fa8","name":"cp047376.exe","release":"2021-06-02T01:57:18","revision":"0","sha1sum":"85dab26fdd510f3929eeb0ea4ac4ca15a5aa16f6","size":"5MB","target_guids":[],"type_of_change":"1","version":"3.00_04-01-2021"}],"id":{"product":"b2f966fef439400c8d3f8bcc5b3de93f","version":"87bebf5e66914d20a538c4a235e4d64f"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p style=\"margin-left:0in; margin-right:0in\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p style=\"margin-left:0in; margin-right:0in\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p style=\"margin-left:0in; margin-right:0in\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p style=\"margin-left:0in; margin-right:0in\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL20 Gen9 (U22) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant DL20 Gen9 (U22)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-26T07:14:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode: 0x000000E2 (CPUID 506E3). This Intel microcode patch provide mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-8696 and CVE-2020-8698. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00381. These issues are not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-24512. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-464. The Intel microcode patches included in this release are version 0x000000EA (CPUID 506E3 and CPUID 906E9). These issues are not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel sighting CVE-2020-24512. This security vulnerability is documented in Intel Security Advisory INTEL-SA-00463. The Intel microcode patches included in this release are version 0x000000EA (CPUID 506E3) and 0x000000EA (CPUID 906E9). This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-8670 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"}],"sw_keys":[{"name":"U22","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component contains version 9.4.5.20 of the QLogic Storport driver which provides Fibre Channel-Host Bus Adapter driver support for HPE storage arrays. "}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1614440","datemodified":"2021-08-27T03:52:40","file_list":["cp048730.xml","cpqsetup.exe","install.xml","ql2300.cat","ql2300.sys","ql2x00.inf","QLOGIC","qlsrvc.exe","QlStorInstaller.dll","readme.txt","release.txt","SysConfig.frm","SysConfig.frm.ja","txtsetup.oem"],"md5sum":"db200c1fe60aa571f50a105bccc8dc9c","name":"cp048730.exe","release":"2021-08-27T03:50:08","revision":"0","sha1sum":"348aff66c2fb2aea4b68024e7e4030e6915e4e74","size":"1MB","target_guids":[],"type_of_change":"1","version":"9.4.5.20"}],"id":{"product":"96c534bee38a42c5885a76a15cc10d73","version":"623c29402ae94eb9b15a1cad5c842b50"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br />\n<br />\nFrom that drive and directory, execute the downloaded file.<br />\n<br />\nClick the &quot;Install&quot; button to proceed with the installation.<br />\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Fibre Channel Adapter Kit for the x64 QLogic Storport Driver for Microsoft Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015D","subven":"1077","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015C","subven":"1077","target_guid":"","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-18T06:47:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Made improvements to the Fabric Port Identification Number (FPIN) and Universal Storage Area Network (SAN) Congestion Mitigation (USCM) Congestion Management algorithms.</li>\n</ul>\n\n<p>Updated&nbsp;to&nbsp;version 9.4.5.20</p>\n","curr_fixes_x_late":"<ul>\n\t<li>Removed the &quot;fwload&quot; registry parameter.</li>\n\t<li>Fixed an unwanted behavior where Link up/down messages were not always logged in the Window System Event log.</li>\n\t<li>Fixed unwanted behavior with the reporting of Fabric Port Identification Number (FPIN) and Universal Storage Area Network (SAN) Congestion Mitigation (USCM) statistics.</li>\n\t<li>Fixed an unwanted behavior where connections to tape drives may fail to recover in the event of &quot;SCSI Check Condition&quot; commands or cable pulls.</li>\n\t<li>Fixed an unwanted behavior where the server may encounter a Blue Screen Of Death (BSOD) 0x0000009f message during shutdown as described in <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00116202en_us\">Advisory: HPE Host Bus Adapters - HPE Platforms Running a Microsoft Windows Server 2016 / 2019 Hyper-V Environment, and Configured With Certain HPE HBAs With the QLogic Storport Driver v9.4.2.20, May Experience a Bug Check 0x9F Event</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"ql2300.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWJNP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ND4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e50","Version":"HPD4"},{"DeviceName":"EG001200JWJNQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ND4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e51","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG000600JWJNP and EG001200JWJNQ"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EG000600JWJNPおよびEG001200JWJNQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;EG000600JWJNP and EG001200JWJNQ&nbsp;Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"4086144","datemodified":"2021-07-24T07:49:40","file_list":["cp048457.xml","cpqsetup.exe","payload.json","setup.dll","SSKYBT512ND4.rel"],"md5sum":"bb2b8af1b17a99808857c8141f8cc6bb","name":"cp048457.exe","release":"2021-07-24T07:43:07","revision":"0","sha1sum":"b47c648826302764583c7e1f112e4a7ea228adb5","size":"3MB","target_guids":["452340a5-3047-3030-3630-304a574a4e50","452340a5-3047-3130-3230-304a574a4e51"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"5ac3ee90b2184fa9828f960cd9d17840","version":"c4457210fdee4ade8edacc5c02939430"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG000600JWJNP and EG001200JWJNQ Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EG000600JWJNPおよびEG001200JWJNQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG001200JWJNQ","target_guid":"452340a5-3047-3130-3230-304a574a4e51","type":"sas"},{"id":"EG000600JWJNP","target_guid":"452340a5-3047-3030-3630-304a574a4e50","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T09:30:19","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001200JWJNQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG000600JWJNP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900374","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware and boot BIOS of Emulex Fibre Channel host bus adapters."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"5429720","datemodified":"2021-08-26T11:24:15","file_list":["cp048599.xml","cpqsetup.exe","elxflashStandalone-windows-12.8.528.12-1/boot/","elxflashStandalone-windows-12.8.528.12-1/boot/UU1280A3.PRG","elxflashStandalone-windows-12.8.528.12-1/firmware/","elxflashStandalone-windows-12.8.528.12-1/firmware/A12852812.grp","elxflashStandalone-windows-12.8.528.12-1/firmware/B12852812.grp","elxflashStandalone-windows-12.8.528.12-1/firmware/UD210X6.ALL","elxflashStandalone-windows-12.8.528.12-1/win/","elxflashStandalone-windows-12.8.528.12-1/win/elxflash.bat","elxflashStandalone-windows-12.8.528.12-1/win/winlpcfg.bat","elxflashStandalone-windows-12.8.528.12-1/win/x64/","elxflashStandalone-windows-12.8.528.12-1/win/x64/boot/","elxflashStandalone-windows-12.8.528.12-1/win/x64/elxflash.exe","elxflashStandalone-windows-12.8.528.12-1/win/x64/ElxLpCfgSvcMsg.dll","elxflashStandalone-windows-12.8.528.12-1/win/x64/firmware/","elxflashStandalone-windows-12.8.528.12-1/win/x64/fwmatrix.txt","elxflashStandalone-windows-12.8.528.12-1/win/x64/libdfc.dll","elxflashStandalone-windows-12.8.528.12-1/win/x64/RM.INI","elxflashStandalone-windows-12.8.528.12-1/win/x64/WinLpCfg.exe","fwmatrix.txt","hpe_fw_matrix.xml","installer.dll","payload.json","readme.txt","elxflashStandalone-windows-12.8.528.12-1/win/x64/readme.txt","reference.xml"],"md5sum":"580099dc7a9e2fad4b563e927f437080","name":"cp048599.exe","release":"2021-08-26T11:09:05","revision":"0","sha1sum":"55319a0926a9f67c118ed0255de9c3e6ab6ce2a4","size":"5MB","target_guids":[],"type_of_change":"1","version":"2021.10.01"}],"id":{"product":"a162e9b322bd4e158c07e459da1a166e","version":"7cfff3801b2d4e85bf7fc2b574853d24"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory.<br />\nThe downloaded file is a self-extracting executable with a filename based on the Component Number.<br />\nFrom that drive and directory, execute the downloaded file.<br />\n<br />\nClick the &quot;Install&quot; button to proceed with the installation.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Fibre Channel Host Bus Adapters for Microsoft Windows Server 2016/2019 x64"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T10:35:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Adapter</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Speed</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Universal Boot Image</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Firmware</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>UEFI</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Boot Bios</strong></p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE 81E 8Gb Single Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.80a3</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">2.10X6</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.183.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.9.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE 82E 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.80a3</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">2.10X6</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.183.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.9.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE 84E 8Gb Quad Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.80a3</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">2.10X6</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.183.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.9.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1000E 16Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1000E 16Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100E 16Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100E 16Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100E Quad Port 16Gb Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"emulex","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Intel ixgben Adapters running under VMware vSphere 6.7."},{"lang":"ja","x_late":"この製品は、VMware vSphere 6.7上で動作するHPE Intel ixgbenアダプターのためのドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;1.8.7.</p>\n"},{"lang":"ja","x_late":"<p>この製品には、ドライバーバージョン1.8.7が含まれています。</p>\n"}],"files":[{"bytes":"199358","datemodified":"2021-05-10T08:42:48","file_list":["/cp045250.xml","/Intel-ixgben_1.9.12.0-1OEM.670.0.0.8169922-offline_bundle-17890246.zip","/Intel-ixgben_1.9.12.0-1OEM.670.0.0.8169922-offline_bundle-17890246.zip/index.xml","/Intel-ixgben_1.9.12.0-1OEM.670.0.0.8169922-offline_bundle-17890246.zip/vendor-index.xml","/Intel-ixgben_1.9.12.0-1OEM.670.0.0.8169922-offline_bundle-17890246.zip/metadata.zip","/Intel-ixgben_1.9.12.0-1OEM.670.0.0.8169922-offline_bundle-17890246.zip/vib20/ixgben/INT_bootbank_ixgben_1.9.12.0-1OEM.670.0.0.8169922.vib","/Intel-ixgben_1.9.12.0-1OEM.670.0.0.8169922-offline_bundle-17890246.zip/metadata.zip/vendor-index.xml","/Intel-ixgben_1.9.12.0-1OEM.670.0.0.8169922-offline_bundle-17890246.zip/metadata.zip/vmware.xml","/Intel-ixgben_1.9.12.0-1OEM.670.0.0.8169922-offline_bundle-17890246.zip/metadata.zip/vibs/ixgben--163231294919778048.xml","/Intel-ixgben_1.9.12.0-1OEM.670.0.0.8169922-offline_bundle-17890246.zip/metadata.zip/bulletins/Intel-ixgben_1.9.12.0-1OEM.670.0.0.8169922.xml"],"md5sum":"db09eb1adc6461df3e0731014ca95b3f","name":"cp045250.zip","release":"2021-05-10T08:40:05","revision":"0","sha1sum":"474350dc7ef523e3a263969d41cd6f23c1e142e0","size":"194KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4a9c3d5c"],"type_of_change":"0","version":"2021.04.05","vib_list":[{"name":"ixgben","version":"1.9.12.0-1OEM.670.0.0.8169922"}]}],"id":{"product":"ec0645c5197f4d97aa2ef8ed23e39857","version":"ca4e89cd36a943ffab7886971238a949"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel ixgben Driver for VMware vSphere 6.7"},{"lang":"ja","x_late":"HPE Intel ixgbenドライバーfor VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c192d","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c211a","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d3","type":"pci","ven":"8086"},{"dev":"1515","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c192d","type":"pci","ven":"8086"},{"dev":"1515","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c211a","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue which notification from Link Partner when executed Link Flow Control settings.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product corrects the maximum supported number of virtual functions.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"ixgben:1.9.12.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel and Mezzanine Host Bus Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"596682","datemodified":"2021-08-26T08:35:38","file_list":["./etc/depmod.d/lpfc.conf","./etc/dracut.conf.d/lpfc.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/elx-lpfc","./lib/modules/4.18.0-240.el8.x86_64/extra/elx-lpfc/lpfc.ko","./usr/share/smartupdate/kmod-elx-lpfc/component.xml"],"md5sum":"c35230e76299b076d7c922b78c69dfa7","name":"kmod-elx-lpfc-12.8.528.7-1.rhel8u3.x86_64.rpm","release":"2021-08-26T08:26:04","revision":"0","sha1sum":"962cf97cc3435b04ae85cf40c55371495df82d17","size":"582KB","target_guids":[],"type_of_change":"1","version":"12.8.528.7"}],"id":{"product":"df557bad91954d4fbe26ad4227197e3e","version":"70b283e1516f4d5f92f0aa642e3766b0"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-elx-lpfc-12.8.509.3-1.rhel8u4.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Red Hat Enterprise Linux 8 Update 3 Server Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters and Mezzanine Host Bus Adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"F100","subven":"10DF","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T10:36:13","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to driver version 12.8.528.7</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"kmod-elx-lpfc","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HP Ethernet 1Gb 2-port 332i Adapter (22E8)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//332i-2x1G-14E4-165F-103C-22E8.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C22E8","Version":"20.18.31"},{"DeviceName":"HP Ethernet 1Gb 2-port 330i Adapter (22BD)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//330i-2x1G-14E4-1665-103C-22BD.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1665103C22BD","Version":"20.18.31"},{"DeviceName":"HP Ethernet 1Gb 2-port 332T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//332T-2x1G-14E4-165F-103C-1786.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C1786","Version":"20.18.31"},{"DeviceName":"HP Ethernet 1Gb 4-port 331FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//331FLR-4x1G-14E4-1657-103C-169D.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C169D","Version":"20.18.31"},{"DeviceName":"HP Ethernet 1Gb 4-port 331T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//331T-4x1G-14E4-1657-103C-3383.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C3383","Version":"20.18.31"},{"DeviceName":"HP Ethernet 1Gb 4-port 331i Adapter (22BE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//331i-4x1G-14E4-1657-103C-22BE.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C22BE","Version":"20.18.31"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NX1 Gigabit Ethernet NICs Boot code, PXE, UMP, NCSI, and CCM code running under Windows Server 2012 R2, Windows Server 2016 and Windows Server 2019."},{"lang":"ja","x_late":"このパッケージには、Windows Server 2012 R2、Windows Server 2016およびWindows Server 2019で動作するHPE ProLiant Broadcom NX1 Gigabit Ethernet NICブートコード、PXE、UMP、NCSI、およびCCMコードをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":null}],"files":[{"bytes":"5628896","datemodified":"2021-02-09T08:11:56","file_list":["bcmnicfwupg.exe","BMAPIa.dll","cp045014.xml","cpqsetup.exe","FW/","FW/330i-2x1G-14E4-1665-103C-22BD.BIN","FW/331FLR-4x1G-14E4-1657-103C-169D.BIN","FW/331i-4x1G-14E4-1657-103C-22BE.BIN","FW/331T-4x1G-14E4-1657-103C-3383.BIN","FW/332i-2x1G-14E4-165F-103C-22E8.BIN","FW/332T-2x1G-14E4-165F-103C-1786.BIN","FW/firmware.json","HPWinFwUpgLib.dll","ja/","ja/NICOFUT.chm","libeay32.dll","libxml2.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","zh-CN/","zh-CN/NICOFUT.chm"],"md5sum":"cc1b80b9c0d7c9e8623c9be2c55885fc","name":"cp045014.exe","release":"2021-02-09T08:04:06","revision":"0","sha1sum":"195b17576e50cf0a058a00044c1213a7a26a99fd","size":"5MB","target_guids":["a6b1a447-382a-5a4f-14E4-165F103C22E8","a6b1a447-382a-5a4f-14E4-1665103C22BD","a6b1a447-382a-5a4f-14E4-165F103C1786","a6b1a447-382a-5a4f-14E4-1657103C169D","a6b1a447-382a-5a4f-14E4-1657103C3383","a6b1a447-382a-5a4f-14E4-1657103C22BE"],"type_of_change":"0","version":"5.2.4.0"}],"id":{"product":"C9279","version":"bb7012258996420cb71c7f833a304bfc"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NX1 1Gb Driver version 214.0.0.0 or greater is required and should be already active","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3f40450a","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"214.0.0.0","description":"HPE Broadcom NX1 1Gb Driver version 214.0.0.0 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<BR>\n<P>From that drive and directory, execute the downloaded file. <BR>\n<P>Click the \"Install\" button to proceed with the installation.</P>\n<P>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</P>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。 ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<BR>\n<P>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。 <BR>\n<P>[インストール]ボタンをクリックして、インストールを開始します。</P>\n<P>アップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</P>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NX1 Online Firmware Upgrade Utility for Windows Server x64 Editions"},{"lang":"ja","x_late":"HPE Broadcom NX1オンラインファームウェアアップグレードユーティリティ for Windows Server x64 Edition"}],"prerequisites":{"required_diskspace":{"size_kb":"5400"},"supported_devices":[{"dev":"165F","subdev":"22E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c22e8","type":"pci","ven":"14E4"},{"dev":"1665","subdev":"22BD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1665103c22bd","type":"pci","ven":"14E4"},{"dev":"165F","subdev":"1786","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c1786","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"169D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c169d","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"3383","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c3383","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"22BE","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c22be","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects the wrong spare number while it was originally not the same as what was written on the label of package.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>This product addresses an issue about lack of information under AHS log.</li>\n\t<li>This product addresses an RSOD issue which appeared intermittently during POST after having a warm reboot.</li>\n\t<li>This product addresses a modification on help string of Family Firmware Version.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"BcmNicFwUpg.exe","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for supported HPE Mellanox adapter cards."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"22533","datemodified":"2021-07-21T06:20:11","file_list":["./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/mst_pci.ko","./lib/modules/5.3.18-22-default/updates/mst_pciconf.ko","./usr/share/smartupdate/kernel-mft-mlnx-kmp-default/component.xml"],"md5sum":"4cd36aec261569c851e731bbad705fb8","name":"kernel-mft-mlnx-kmp-default-4.17.0_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-07-21T06:09:05","revision":"0","sha1sum":"870af29073743c051e862c2b42b0c15d0ab1c4bb","size":"22KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"type_of_change":"1","version":"4.17"},{"bytes":"10001268","datemodified":"2021-07-21T06:22:58","file_list":["./etc/bash_completion.d/mft/mft_base_autocomplete","./etc/bash_completion.d/mft/mft_help_to_completion.py","./etc/init.d/mst","./etc/mft/RPMS/mft","./etc/mft/mft.conf","./etc/mft/mst.conf","./usr/bin/flint","./usr/bin/flint_ext","./usr/bin/mcra","./usr/bin/mdevices_info","./usr/bin/mft_uninstall.sh","./usr/bin/minit","./usr/bin/mlxfwreset","./usr/bin/mlxfwstress","./usr/bin/mlxfwstress_ext","./usr/bin/mlxgearbox","./usr/bin/mlxpci","./usr/bin/mlxprivhost","./usr/bin/mst","./usr/bin/mst_cable","./usr/bin/mst_ib_add","./usr/bin/mstop","./usr/bin/resourcedump","./usr/bin/resourceparse","./usr/bin/stedump","./usr/share/man/man1","./usr/share/man/man1/flint.1.gz","./usr/share/man/man1/mcra.1.gz","./usr/share/man/man1/mdevices_info.1.gz","./usr/share/man/man1/minit.1.gz","./usr/share/man/man1/mlxfwreset.1.gz","./usr/share/man/man1/mst.1.gz","./usr/share/man/man1/mstop.1.gz","./usr/share/mft/fw_stress_db","./usr/share/mft/fw_stress_db/stress_types.db","./usr/share/mft/prm_dbs","./usr/share/mft/prm_dbs/hca","./usr/share/mft/prm_dbs/hca/ext","./usr/share/mft/prm_dbs/hca/ext/register_access_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.dat","./usr/share/mft/prm_dbs/switch","./usr/share/mft/prm_dbs/switch/ext","./usr/share/mft/prm_dbs/switch/ext/register_access_table.adb","./usr/share/mft/prm_dbs/switch/ext/register_access_table.dat","./usr/share/smartupdate/mft/component.xml"],"md5sum":"0c1152c4809d4d2e5775766524384f6e","name":"mft-4.17.0-106.sles15sp2.x86_64.rpm","release":"2021-07-21T06:09:05","revision":"0","sha1sum":"20b7ea0c74483cc7e061859710d3ac323a535afe","size":"9MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"type_of_change":"1","version":"4.17"}],"id":{"product":"d60ce0b82db54a2e881c0e0bf9e229a2","version":"9efe759cd92e463eb6484a5369939420"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\nTo install or upgrade the driver:<br />\n<br />\nIf using 4.12.14-195-default kernel or any future errata:<br />\n<strong># rpm -Uvh kernel-mft-mlnx-kmp-default-4.17.0_k4.12.14_195-1.sles15sp2.x86_64.rpm&nbsp;&nbsp;mft-4.17.0-64.sles15sp2.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for SUSE Linux Enterprise Server 15 SP2 (AMD64/EM64T)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"101f","subdev":"0012","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30012","type":"pci","ven":"15b3"},{"dev":"101f","subdev":"0007","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30007","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T18:00:49","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","latest_fixes_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n"},{"curr_enhancements_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","curr_fixes_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"kernel-mft-mlnx-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mft","sw_key_expectedpath":"software:rpm"},{"name":"kernel-mft-mlnx-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mft","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for supported HPE Mellanox adapter cards."},{"lang":"ja","x_late":"サポートされているHPE Mellanoxアダプターカード用のHPE Mellanox MFTドライバーおよびFirmware Tool。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"22253","datemodified":"2021-07-21T06:04:25","file_list":["./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/mst_pci.ko","./lib/modules/4.12.14-94.41-default/updates/mst_pciconf.ko","./usr/share/smartupdate/kernel-mft-mlnx-kmp-default/component.xml"],"md5sum":"a17edc1d346a6a59526cd67351ad9e5e","name":"kernel-mft-mlnx-kmp-default-4.17.0_k4.12.14_94.41-1.sles12sp4.x86_64.rpm","release":"2021-07-21T05:52:13","revision":"0","sha1sum":"4235643fa0eb4ea68fd96de992fe8912d5be1809","size":"21KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"type_of_change":"1","version":"4.17"},{"bytes":"10001288","datemodified":"2021-07-21T06:03:07","file_list":["./etc/bash_completion.d/mft/mft_base_autocomplete","./etc/bash_completion.d/mft/mft_help_to_completion.py","./etc/init.d/mst","./etc/mft/RPMS/mft","./etc/mft/mft.conf","./etc/mft/mst.conf","./usr/bin/flint","./usr/bin/flint_ext","./usr/bin/mcra","./usr/bin/mdevices_info","./usr/bin/mft_uninstall.sh","./usr/bin/minit","./usr/bin/mlxfwreset","./usr/bin/mlxfwstress","./usr/bin/mlxfwstress_ext","./usr/bin/mlxgearbox","./usr/bin/mlxpci","./usr/bin/mlxprivhost","./usr/bin/mst","./usr/bin/mst_cable","./usr/bin/mst_ib_add","./usr/bin/mstop","./usr/bin/resourcedump","./usr/bin/resourceparse","./usr/bin/stedump","./usr/share/man/man1","./usr/share/man/man1/flint.1.gz","./usr/share/man/man1/mcra.1.gz","./usr/share/man/man1/mdevices_info.1.gz","./usr/share/man/man1/minit.1.gz","./usr/share/man/man1/mlxfwreset.1.gz","./usr/share/man/man1/mst.1.gz","./usr/share/man/man1/mstop.1.gz","./usr/share/mft/fw_stress_db","./usr/share/mft/fw_stress_db/stress_types.db","./usr/share/mft/prm_dbs","./usr/share/mft/prm_dbs/hca","./usr/share/mft/prm_dbs/hca/ext","./usr/share/mft/prm_dbs/hca/ext/register_access_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.dat","./usr/share/mft/prm_dbs/switch","./usr/share/mft/prm_dbs/switch/ext","./usr/share/mft/prm_dbs/switch/ext/register_access_table.adb","./usr/share/mft/prm_dbs/switch/ext/register_access_table.dat","./usr/share/smartupdate/mft/component.xml"],"md5sum":"128b14a3ca67fe155ebae03553bd5e94","name":"mft-4.17.0-106.sles12sp4.x86_64.rpm","release":"2021-07-21T05:52:13","revision":"0","sha1sum":"4cdf6a382e178cc6ebccbd22efe027e1cd25b9e8","size":"9MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"type_of_change":"1","version":"4.17"}],"id":{"product":"fb694776c4964491b586e98c556b93d2","version":"f5d49f1c3d0146f9ab4222bd3257bb0f"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using 4.12.14-94.41-default&nbsp;kernel or any future errata:<br />\n<br />\n<strong># rpm -Uvh kernel-mft-mlnx-kmp-default-4.17.0_k4.12.14_94.41-1.sles12sp4.x86_64.rpm&nbsp; mft-4.17.0-64.sles12sp4.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for SUSE Linux Enterprise Server 12 SP4 (AMD64/EM64T)"},{"lang":"ja","x_late":"SUSE Linux Enterprise Server 12 SP4（AMD64/EM64T）向けのHPE Mellanox MFTドライバーおよびFirmware Tools"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"101f","subdev":"0012","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30012","type":"pci","ven":"15b3"},{"dev":"101f","subdev":"0007","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30007","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T18:00:46","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","latest_fixes_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n"},{"curr_enhancements_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","curr_fixes_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"kernel-mft-mlnx-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mft","sw_key_expectedpath":"software:rpm"},{"name":"kernel-mft-mlnx-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mft","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWFWK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRH620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-30475746574b","Version":"HPG6"},{"DeviceName":"MB002000GWFWL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRH620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-30475746574c","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB001000GWFWK and MB002000GWFWL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB001000GWFWK and MB002000GWFWL Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG5</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG5<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"4004968","datemodified":"2021-07-23T19:35:21","file_list":["cp048557.xml","cpqsetup.exe","payload.json","setup.dll","WRH620G6.rel"],"md5sum":"2f4ac3306a8e8df6f6f6ac810db0055f","name":"cp048557.exe","release":"2021-07-23T19:28:07","revision":"0","sha1sum":"ab221e04a4aed0a50de546a8036ee3ca8eb2a35b","size":"3MB","target_guids":["4d2340a5-3042-3130-3030-30475746574b","4d2340a5-3042-3230-3030-30475746574c"],"type_of_change":"1","version":"HPG6"}],"id":{"product":"57a91e286d3e413c8468376551e64001","version":"34c053d109ae450f8d8adc1896d5bfff"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB001000GWFWK and MB002000GWFWL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB001000GWFWKおよびMB002000GWFWLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB001000GWFWK","target_guid":"4d2340a5-3042-3130-3030-30475746574b","type":"sata"},{"id":"MB002000GWFWL","target_guid":"4d2340a5-3042-3230-3030-30475746574c","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T05:42:01","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB002000GWFWL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB001000GWFWK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000GFJTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGNTG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-3047464a5445","Version":"HPG5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SATA drive models: MM1000GFJTE"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します： MM1000GFJTE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MM1000GFJTE Drive</p>\n\n<p><strong><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br />\n<br />\n<strong><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4<br />\n<br />\n<strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4<br />\n<br />\n<strong><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Enhancements/New Features :</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5423037","datemodified":"2021-07-23T07:50:21","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG5-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG5-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG5-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG5-6.1/CP046354.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG5-6.1/SAVGNTG5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG5-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG5-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG5-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG5-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046354.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046354.scexe"],"md5sum":"ab69c699f5cb3ff045930fe82a842b80","name":"firmware-hdd-95af9a555e-HPG5-6.1.x86_64.rpm","release":"2021-07-23T07:36:06","revision":"0","sha1sum":"06b139ec7ff900359136b2b5e72a8ab06e2d0469","size":"5MB","target_guids":["002340a5-4d00-314d-3030-3047464a5445"],"type_of_change":"0","version":"HPG5"}],"id":{"product":"e8a7c3696813408f916249b859b6b722","version":"1a18f589c1164370908a926a777e95a4"},"installation":{"command":"CP040344.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MM1000GFJTE Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MM1000GFJTE","target_guid":"002340a5-4d00-314d-3030-3047464a5445","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-25T07:08:46","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MM1000GFJTE","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK0960GECQK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSV843G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304b-3936-30474543514b","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MK0960GECQK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;&nbsp;(x64)&nbsp;- MK0960GECQK Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong><strong>Enhancements/New Features</strong>:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Firmware fixes intermittent data corruption issue associated with unaligned sequential write operations.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"2731608","datemodified":"2021-07-25T16:29:03","file_list":["cp048621.xml","cpqsetup.exe","GSV843G3.rel","payload.json","setup.dll"],"md5sum":"7ccdaa92e112660621c354fae951f888","name":"cp048621.exe","release":"2021-07-25T16:22:07","revision":"0","sha1sum":"d43e4392be5f35348f14421c50bb4d06157c8281","size":"2MB","target_guids":["002340a5-4d00-304b-3936-30474543514b"],"type_of_change":"2","version":"HPG3"}],"id":{"product":"d3eb22b830d045a89e85774c90558992","version":"7863a89aa5284ec39e86949796165b8e"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MK0960GECQK Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MK0960GECQKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"MK0960GECQK","target_guid":"002340a5-4d00-304b-3936-30474543514b","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T12:48:37","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":"<ul>\n\t<li>Firmware fixes intermittent data corruption issue associated with unaligned sequential write operations.</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Firmware fixes intermittent data corruption issue associated with unaligned sequential write operations.</li>\n</ul>","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK0960GECQK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900083","languages":[{"lang":"tw","x_late":"韌體 ─ 電源管理"},{"lang":"en","x_late":"Firmware - Power Management"},{"lang":"ko","x_late":"펌웨어 - 전원 관리"},{"lang":"ja","x_late":"ファームウェア - パワー マネジメント"},{"lang":"cn","x_late":"固件 - 电源管理"}]}],"description":[{"lang":"en","x_late":"This component updates the Power Management Controller firmware. "},{"lang":"ja","x_late":"このコンポーネントは、Power Management Controllerファームウェアをアップデートします。 "}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"382659","datemodified":"2015-07-28T14:58:09","file_list":["./usr/lib/i386-linux-gnu/hp-firmware-powerpic-dl580-4.1-5","./usr/lib/i386-linux-gnu/hp-firmware-powerpic-dl580-4.1-5/.cpq_package.inc","./usr/lib/i386-linux-gnu/hp-firmware-powerpic-dl580-4.1-5/.hpsetup","./usr/lib/i386-linux-gnu/hp-firmware-powerpic-dl580-4.1-5/CP027686.xml","./usr/lib/i386-linux-gnu/hp-firmware-powerpic-dl580-4.1-5/SNARFR41.hex","./usr/lib/i386-linux-gnu/hp-firmware-powerpic-dl580-4.1-5/firmware.ini","./usr/lib/i386-linux-gnu/hp-firmware-powerpic-dl580-4.1-5/hpsetup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP027686.scexe"],"md5sum":"6518c0f27396be8b9cb7b12524ac23df","name":"hp-firmware-powerpic-dl580-4.1-5.i386.rpm","release":"2015-07-28T14:59:18","revision":"0","sha1sum":"7339e25f3f1d7c4a27db2aca05d26fa5f8842b13","size":"373KB","target_guids":[],"type_of_change":"1","version":"4.1"}],"id":{"product":"1fda2856afe34ef885a535a6a8013679","version":"c8180f8a3240446a9bd22383987ee57d"},"installation":{"command":"cpqsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HP ProLiant Agentless Management Service (hp-ams) and HP SNMP Agents (hp-snmp-agents) are both running.&nbsp; HP does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;HP Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>\n\t<p>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</p>\n\t</li>\n\t<li>\n\t<p>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\hp\\swpackages on the USB key.</p>\n\n\t<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\t</li>\n</ul>\n\n<ul>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"Online ROM Flash for Linux - Power Management Controller "},{"lang":"ja","x_late":"オンラインROMフラッシュ for Linux - Power Management Controller "}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"5","minor":"0","name":"Red Hat Enterprise Linux 5 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2015-08-28T14:35:19","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>\n <strong>Important Notes:</strong><br />\n Ver. 4.1(D) contains updates to the OS installation support for HP Smart Update Manager. The Power Management Controller Firmware contained within Ver. 4.1(D) is Ver. 4.1. Therefore, it is not necessary to upgrade with ver. 4.1(D), if the Power Management Controller firmware version is 4.1.</p>\n<p>\n <b>Firmware Dependencies:</b></p>\nNone\n<p>\n <b>Enhancements/New Features:</b><br />\n This is the initial version of the firmware.<br />\n <b>Known Issues:</b></p>\nThe smart component prompts for reboot unnecessarily when the installation procedure is completed. Reboot is not required after installation for updates to take effect and hardware stability to be maintained.","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>Ver.&nbsp;4.1 (E)&nbsp;contains a change to the Firmware RPM install command name from &ldquo;cpqsetup&rdquo; to &ldquo;hpsetup&rdquo; and is functionally equivalent to ver. 4.1.&nbsp; It is not necessary to upgrade with Revision&nbsp;E if a previous component revision was used to upgrade the firmware to version 4.1.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>This is the initial version of the firmware.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>The smart component prompts for reboot unnecessarily when the installation procedure is completed. Reboot is not required after installation for updates to take effect and hardware stability to be maintained.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HP ProLiant DL580 Gen9 Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"}],"sw_keys":[{"name":"PowerPIC-DL580","sw_key_expectedpath":"firmware:QLOGIC"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager（SUM）と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5872768","datemodified":"2021-05-18T14:26:26","file_list":["SignedImageInstaller64.dll","U18_2.90_04_29_2021.signed.flash","cp047897.xml","cpqsetup.exe","cpqsysio64.sys"],"md5sum":"0a4a97b98010f5b0fcddd61cec170956","name":"cp047897.exe","release":"2021-05-18T14:10:05","revision":"0","sha1sum":"7e4296880cdf6fb3019ddddd1ac2d598234663a4","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021"}],"id":{"product":"153df6fb8edb4c87a452c4f40918a3d5","version":"057a7e1407684e51bd6544bb51538246"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Windows x64 的線上 ROM 更新元件 - HPE ProLiant XL730f/XL740f/XL750f Gen9 (U18) 伺服器"},{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant XL730f/XL740f/XL750f Gen9 (U18) Servers"},{"lang":"ko","x_late":"Windows x64용 온라인 ROM 플래시 구성 요소 - HPE ProLiant XL730f/XL740f/XL750f Gen9 (U18) 서버"},{"lang":"cn","x_late":"面向 Windows x64 的在线 ROM Flash 组件 - HPE ProLiant XL730f/XL740f/XL750f Gen9 (U18) 服务器"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant XL730f/XL740f/XL750f Gen9 (U18)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-06T21:37:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","latest_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358.  These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390.  These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"}],"sw_keys":[{"name":"U18","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JXLBA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WpariscASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a584c4241","Version":"HPD2"},{"DeviceName":"MB018000JXLAU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WpariscASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a584c4155","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB016000JXLBA and MB018000JXLAU"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;-&nbsp;MB016000JXLBA and MB018000JXLAU Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>VENDOR IDENTIFICATION field changed from &ldquo;HP&rdquo; to &ldquo;HPE&rdquo; and Reliability improvements.</li>\n</ul>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"6930734","datemodified":"2021-08-11T18:37:38","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD2-1.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD2-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD2-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD2-1.1/CP049255.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD2-1.1/WpariscASFD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD2-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD2-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD2-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD2-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049255.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049255.scexe"],"md5sum":"6f1056cbdba6ba36246e778468fb065b","name":"firmware-hdd-d550523365-HPD2-1.1.x86_64.rpm","release":"2021-08-11T18:24:06","revision":"0","sha1sum":"d34d0787587f53761d1c93599793df54da008d43","size":"6MB","target_guids":["4d2340a5-3042-3631-3030-304a584c4241","4d2340a5-3042-3831-3030-304a584c4155"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"d287970503c042a480f1860ec2c054c7","version":"eeffc0a67db34a318cb6db36f76f16da"},"installation":{"command":"CP040352.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB016000JXLBA and MB018000JXLAU Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB016000JXLBA","target_guid":"4d2340a5-3042-3631-3030-304a584c4241","type":"sas"},{"id":"MB018000JXLAU","target_guid":"4d2340a5-3042-3831-3030-304a584c4155","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-11T18:15:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>VENDOR IDENTIFICATION field changed from &ldquo;HP&rdquo; to &ldquo;HPE&rdquo; and Reliability improvements.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB018000JXLAU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB016000JXLBA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000150GWCNN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3135-304757434e4e","Version":"HPG1"},{"DeviceName":"VK000240GWCNP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757434e50","Version":"HPG1"},{"DeviceName":"VK000480GWCNQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757434e51","Version":"HPG1"},{"DeviceName":"VK000960GWCNR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757434e52","Version":"HPG1"},{"DeviceName":"VK001600GWCNT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3630-304757434e54","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000150GWCNN, VK000240GWCNP, VK000480GWCNQ, VK000960GWCNR and VK001600GWCNT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK000150GWCNN, VK000240GWCNP, VK000480GWCNQ, VK000960GWCNR, and VK001600GWCNT Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"15854073","datemodified":"2021-08-27T08:58:05","file_list":["/CP048405_BUILD_4.data","/CP048405.vmexe","/CP048405.vmexe64","/CP048405.vmfile","/CP048405_VMw.zip","/CP048405.xml","/payload.json","/CP048405_VMw.zip/index.xml","/CP048405_VMw.zip/vendor-index.xml","/CP048405_VMw.zip/metadata.zip","/CP048405_VMw.zip/vib20/CP048405/HPE_bootbank_CP048405_HPG1.4-7.0.0.15843807.vib","/CP048405_VMw.zip/metadata.zip/vendor-index.xml","/CP048405_VMw.zip/metadata.zip/vmware.xml","/CP048405_VMw.zip/metadata.zip/vibs/CP048405-245563376691318975.xml","/CP048405_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048405_HPG1.4-7.0.0.15843807.xml"],"md5sum":"312475481c55b256fb34662549cae429","name":"CP048405.zip","release":"2021-08-27T08:52:31","revision":"0","sha1sum":"5dd277bcc601b9a45bd28e816cc23a019facb1b2","size":"15MB","target_guids":["562340a5-304b-3030-3135-304757434e4e","562340a5-304b-3030-3234-304757434e50","562340a5-304b-3030-3438-304757434e51","562340a5-304b-3030-3936-304757434e52","562340a5-304b-3130-3630-304757434e54"],"type_of_change":"1","version":"HPG1","vib_list":[{"name":"CP048405","version":"HPG1.4-7.0.0.15843807"}]}],"id":{"product":"1af1a5a1ad4c4d1883e16ca0bd801d36","version":"6f058c7df25543aea032cfd3c9354ee5"},"installation":{"command":"CP042539.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK000150GWCNN, VK000240GWCNP, VK000480GWCNQ, VK000960GWCNR and VK001600GWCNT Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VK000150GWCNN、VK000240GWCNP、VK000480GWCNQ、VK000960GWCNR、およびVK001600GWCNTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VK001600GWCNT","target_guid":"562340a5-304b-3130-3630-304757434e54","type":"sata"},{"id":"VK000960GWCNR","target_guid":"562340a5-304b-3030-3936-304757434e52","type":"sata"},{"id":"VK000480GWCNQ","target_guid":"562340a5-304b-3030-3438-304757434e51","type":"sata"},{"id":"VK000240GWCNP","target_guid":"562340a5-304b-3030-3234-304757434e50","type":"sata"},{"id":"VK000150GWCNN","target_guid":"562340a5-304b-3030-3135-304757434e4e","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T03:10:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK000480GWCNQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000150GWCNN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001600GWCNT","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWCNR","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWCNP","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900374","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware and boot BIOS of Emulex Mezzanine Fibre channel host bus adapters."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"3925896","datemodified":"2021-08-27T08:40:46","file_list":["cp049107.xml","cpqsetup.exe","elxflashStandalone-windows-12.8.352.12-1/boot/","elxflashStandalone-windows-12.8.352.12-1/firmware/","elxflashStandalone-windows-12.8.352.12-1/firmware/A12835212.grp","elxflashStandalone-windows-12.8.352.12-1/win/","elxflashStandalone-windows-12.8.352.12-1/win/elxflash.bat","elxflashStandalone-windows-12.8.352.12-1/win/winlpcfg.bat","elxflashStandalone-windows-12.8.352.12-1/win/x64/","elxflashStandalone-windows-12.8.352.12-1/win/x64/boot/","elxflashStandalone-windows-12.8.352.12-1/win/x64/elxflash.exe","elxflashStandalone-windows-12.8.352.12-1/win/x64/ElxLpCfgSvcMsg.dll","elxflashStandalone-windows-12.8.352.12-1/win/x64/firmware/","elxflashStandalone-windows-12.8.352.12-1/win/x64/fwmatrix.txt","elxflashStandalone-windows-12.8.352.12-1/win/x64/libdfc.dll","elxflashStandalone-windows-12.8.352.12-1/win/x64/RM.INI","elxflashStandalone-windows-12.8.352.12-1/win/x64/WinLpCfg.exe","fwmatrix.txt","hpe_fw_matrix.xml","installer.dll","payload.json","readme.txt","elxflashStandalone-windows-12.8.352.12-1/win/x64/readme.txt","reference.xml"],"md5sum":"940f335b8e4b88195247b336472612ea","name":"cp049107.exe","release":"2021-08-27T08:25:45","revision":"0","sha1sum":"c63e939ddbf3be2872ee375de1148c9f775007d7","size":"3MB","target_guids":[],"type_of_change":"1","version":"2021.10.01"}],"id":{"product":"5ede6a140775435bac859b549a84e133","version":"1580c3d510ae4e2c8ad8c6aaa840910a"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory.<br />\nThe downloaded file is a self-extracting executable with a filename based on the Component Number.<br />\nFrom that drive and directory, execute the downloaded file.<br />\n<br />\nClick the &quot;Install&quot; button to proceed with the installation.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Mezzanine Fibre Channel Host Bus Adapters for Microsoft Windows Server 2012R2 x64"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-23T06:32:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This Firmware package contains following firmware versions:</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 16Gb LPe1605 Fibre Channel Host Bus Adapter for BladeSystem c-Class</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>12.8.352.12</td>\n\t\t\t<td>12.8.352.12</td>\n\t\t\t<td>12.8.352.10</td>\n\t\t\t<td>12.8.352.5</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"emulex","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel and Mezzanine Host Bus Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"532283","datemodified":"2021-08-26T08:21:11","file_list":["./etc/depmod.d/lpfc.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/elx-lpfc","./lib/modules/3.10.0-1127.el7.x86_64/extra/elx-lpfc/lpfc.ko","./usr/share/smartupdate/kmod-elx-lpfc/component.xml"],"md5sum":"648d2ea7e2aed5d77b8de1b47faaf630","name":"kmod-elx-lpfc-12.8.528.7-1.rhel7u8.x86_64.rpm","release":"2021-08-26T08:13:05","revision":"0","sha1sum":"ebfd26d3b382000f30230eb531d413b6eef02fb3","size":"519KB","target_guids":[],"type_of_change":"1","version":"12.8.528.7"}],"id":{"product":"62bcf6cfc14940858e047421873f6b67","version":"b0055975b8ec4a7496b43966d85b6a40"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-elx-lpfc-12.8.509.3-1.rhel8u4.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Red Hat Enterprise Linux 7 Update 8 Server Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters and Mezzanine Host Bus Adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"F100","subven":"10DF","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T10:36:10","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to driver version 12.8.528.7</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"kmod-elx-lpfc","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZPLJ1T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK75H3Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3154-3648f52fd02c","Version":"EPK75H3Q"},{"DeviceName":"MZPLJ3T2HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK75H3Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3354-3248fdc50136","Version":"EPK75H3Q"},{"DeviceName":"MZPLJ6T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK75H3Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3654-3448bda98199","Version":"EPK75H3Q"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MZPLJ1T6HBJR-000H3, MZPLJ3T2HBJR-000H3 and MZPLJ6T4HALA-000H3"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows&nbsp;(x64) - MZPLJ1T6HBJR-000H3, MZPLJ3T2HBJR-000H3 and MZPLJ6T4HALA-000H3&nbsp; Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>EPK75H3Q</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; EPK74H3Q</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; EPK74H3Q</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>&nbsp; &nbsp; &nbsp;&nbsp;Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Fixed False UECC issue at idle power mode.</li>\n\t<li>Old FW download Blocking (EPK70H3Q~EPK74H3Q).</li>\n\t<li>FW is changed off the option of TX data alignment for each lane.</li>\n\t<li>FW is changed to clear the interrupt after TLP Complete when PCIe config read operation.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"7568064","datemodified":"2021-07-24T08:40:42","file_list":["cp048301.xml","cpqsetup.exe","EPK75H3Q.rel","payload.json","setup.dll"],"md5sum":"10e1262bc2f7aa07518cc5361320528a","name":"cp048301.exe","release":"2021-07-24T08:33:14","revision":"0","sha1sum":"ab70f50275318527a79a657c6467622bdb09cc0f","size":"7MB","target_guids":["4d2340a5-505a-4a4c-3154-3648f52fd02c","4d2340a5-505a-4a4c-3354-3248fdc50136","4d2340a5-505a-4a4c-3654-3448bda98199"],"type_of_change":"2","version":"EPK75H3Q"}],"id":{"product":"99c23ff7c8d6427fabec401028b615d8","version":"cae6f90f03de48aa8b92195060b0d66b"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) - MZPLJ1T6HBJR-000H3, MZPLJ3T2HBJR-000H3 and MZPLJ6T4HALA-000H3 Drives"},{"lang":"ja","x_late":"オンラインNVMeSSDフラッシュコンポーネントfor Windows (x64) - MZPLJ1T6HBJR-000H3、MZPLJ3T2HBJR-000H3、およびMZPLJ6T4HALA-000H3ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MZPLJ1T6HBJR-000H3","target_guid":"4d2340a5-505a-4a4c-3154-3648f52fd02c","type":"nvme"},{"id":"MZPLJ6T4HALA-000H3","target_guid":"4d2340a5-505a-4a4c-3654-3448bda98199","type":"nvme"},{"id":"MZPLJ3T2HBJR-000H3","target_guid":"4d2340a5-505a-4a4c-3354-3248fdc50136","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-03T11:11:39","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Fixed False UECC issue at idle power mode.</li>\n\t<li>Old FW download Blocking (EPK70H3Q~EPK74H3Q).</li>\n\t<li>FW is changed off the option of TX data alignment for each lane.</li>\n\t<li>FW is changed to clear the interrupt after TLP Complete when PCIe config read operation.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL: <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us\" style=\"color: rgb(5, 99, 193); text-decoration: underline;\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us</a></li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Fixed False UECC issue at idle power mode.</li>\n\t<li>Old FW download Blocking (EPK70H3Q~EPK74H3Q).</li>\n\t<li>FW is changed off the option of TX data alignment for each lane.</li>\n\t<li>FW is changed to clear the interrupt after TLP Complete when PCIe config read operation.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MZPLJ6T4HALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZPLJ1T6HBJR-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZPLJ3T2HBJR-000H3","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5942856","datemodified":"2021-06-18T22:00:55","file_list":["I38_2.90_04_29_2021.signed.flash","SignedImageInstaller64.dll","cp048737.xml","cpqsetup.exe","cpqsysio64.sys"],"md5sum":"99baae06efc9484f6a21831b5158f46c","name":"cp048737.exe","release":"2021-06-18T21:44:06","revision":"0","sha1sum":"e9cd1ce3465291684cd70eeaefc7a84b8ee092f6","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021"}],"id":{"product":"c67540411e6b4fb08ed7b6799938f22f","version":"4a303ec9b6554e259ef8448fc2b63f9c"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p><strong>To verify the HPE SHA256 Authenticode digital signature, do the following steps:</strong><br />\n1. &nbsp; &nbsp;Download &lt;file name&gt;.exe to a system running a supported version of Microsoft Windows Server OS. By downloading this file, you are agreeing to the license terms in HPE License Agreement v1.pdf, listed in the &#39;License&#39; field.<br />\n2. &nbsp; &nbsp;Right-click the filename then select Properties<br />\n3. &nbsp; &nbsp;When the Properties window displays, click the Digital Signature tab<br />\n4. &nbsp; &nbsp;Select the first entry in the Signature List and click the Details button.&nbsp;<br />\n5. &nbsp; &nbsp;The signature status will display at the top of the Details dialog.<br />\n6. &nbsp; &nbsp;If the signature message states that &ldquo;This digital signature is OK.&rdquo;, then the firmware package is authenticated as an HPE package<br />\n7. &nbsp; &nbsp;If the message &ldquo;This digital signature is not OK.&rdquo; displays, then do the following:<br />\n&nbsp; &nbsp; &nbsp; &nbsp; a. &nbsp; &nbsp;Do not deploy the firmware.<br />\n&nbsp; &nbsp; &nbsp; &nbsp; b. &nbsp; &nbsp;Download firmware a second time and verify the signature again. If the signature is not OK, then contact HPE Technical Support.&nbsp;</p>\n\n<p><br />\n<strong>To verify the SHA256 hash value, do the following steps:</strong><br />\n1. &nbsp; &nbsp;Use Microsoft Windows CRC/SHA tool to calculate the SHA256 hash value for &lt;FileName&gt;.exe.&nbsp;<br />\n2. &nbsp; &nbsp;Compare the calculated value with the SHA256 value displayed in the Installation Instruction tab of the HPE Support Center download page.<br />\n&bull; &nbsp; &nbsp;If the values match, then the integrity of the downloaded file has been verified.<br />\n&bull; &nbsp; &nbsp;If the values do not match, do not deploy the file or its contents.<br />\n&bull; &nbsp; &nbsp;Download the file a second time and compare the new hash value.&nbsp;<br />\n&bull; &nbsp; &nbsp;If the hash values do not match, then do not deploy the downloaded file and contact HPE Technical Support.</p>\n\n<p>&nbsp;</p>\n\n<p>Execute the file &nbsp;&lt;filename&gt;.exe and follow onscreen instructions to finish the installation.<br />\nAfter the driver installaton is complete, please restart the server.</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant BL660c Gen9 (I38) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant BL660c Gen9 (I38)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-18T21:23:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.</p>\n\n<p>Ver. 2.90_04-29-2021 (B) contains support for Windows Server 2019.&nbsp; It is functionally equivalent to ver. 2.90_04-29-2021.&nbsp; It is not necessary to upgrade with version 2.90_04-29-2021 (B) if a previous component revision was used to upgrade the firmware to ver. 2.90_04-29-2021.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463. These issues are not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"}],"sw_keys":[{"name":"I38","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"19300214","languages":[{"lang":"en","x_late":"Firmware (Entitlement Required) - Storage Controller"},{"lang":"ja","x_late":"ファームウェア (ライセンスが必要) - ストレージコントローラー"}]}],"description":[{"lang":"tw","x_late":"此套件可更新連接智慧陣列控制器及主機匯流排配接卡的 HP D2600 與 D2700 磁碟機機櫃韌體。此套件內含的 I/O 模組韌體新增改善功能，可修正在初版產品發行後使用與額外資格測試期間發現的問題。"},{"lang":"en","x_late":"This package updates the firmware on HP D2600 and D2700 Disk enclosures attached to Smart Array Controllers and Host Bus Adapters. I/O module firmware included in this package adds improvements and corrects issues found during use and additional qualification testing after initial product release."},{"lang":"ko","x_late":"이 패키지는 스마트 어레이 컨트롤러 및 호스트 버스 어댑터에 장착되어 있는 HP D2600 및 D2700 디스크 인클로저의 펌웨어를 업데이트합니다. 이 패키지에 포함된 I/O 모듈 펌웨어에서는 제품 출시 후 사용 또는 추가 적격 테스트 과정에서 발견된 문제를 수정하고 개선 사항을 추가하였습니다."},{"lang":"cn","x_late":"该软件包用于更新连接至智能阵列控制器和主机总线适配器的HP D2600和D2700磁盘机柜固件。此软件包中包含的 I/O 模块固件添加了改进，并纠正了首次产品发布后在使用期间及额外资格测试时发现的问题。"},{"lang":"ja","x_late":"このパッケージは、Smartアレイコントローラーおよびホストバスアダプターに接続されているHP D2600およびD2700ディスクエンクロージャーのファームウェアをアップデートします。 このパッケージに含まれるI/Oモジュールのファームウェアは、初期リリース後、実際の使用中および追加テストで見つかった問題の改善と修正を追加します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"4640664","datemodified":"2015-11-30T23:28:25","file_list":["CamFlash.dll","CamFlash.dll.2.config","CAMSPR0150_6G_app_4MB_ai.pmc","cp028806.xml","cpqsetup.exe","Microsoft.VC90.CRT.manifest","msvcm90.dll","msvcp110.dll","msvcp90.dll","msvcr110.dll","msvcr90.dll"],"md5sum":"dcf60f3a04f275767f9d606ac5d0f4b6","name":"cp028806.exe","release":"2016-10-07T00:00:00","revision":"1","sha1sum":"f7406fb3b516f2400dde54397a86d4066e410a8b","size":"4MB","target_guids":[],"type_of_change":"1","version":"0150"}],"id":{"product":"5f78fc3b4e0e4c3db7002c50957e782b","version":"6d71ca35ea2d43468453f871ca0717a5"},"installation":{"command":"cpqsetup.exe","command_params":"/iCAMSPR0150_6G_app_4MB_ai.pmc /v0150 /t\"D2600 SAS AJ940A\" /t\"D2700 SAS AJ941A\" /t\"260 SAS AJ940A\" /t\"270 SAS AJ941A\" /t\"D2x00 Disk Enc.\" /t\"MDS260 CAMARO\" /t\"MDS270 CAMARO\"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Firmware installation i<strong>nstructions</strong>&nbsp;for Smart Array configurations:</strong><br />\n<br />\nFirmware is embedded in the downloaded file, which is a self-extracting, executable module. Execute this module from the command line console or the Windows graphical user interface.</p>\n\n<p><strong>GUI Option:</strong></p>\n\n<ol>\n\t<li>Place the downloaded firmware package in a temporary directory.</li>\n\t<li>Using Windows Explorer, navigate to the directory containing the download.</li>\n\t<li>Double click the executable file.</li>\n\t<li>Follow onscreen instructions.</li>\n</ol>\n\n<p><strong>CLI Option:</strong></p>\n\n<p>Execute the Smart Component by entering the following command: CP0xxxxx.exe /s</p>\n\n<p><strong>To use HP Smart Update Manager from the </strong><strong><a href=\"http://www.hp.com/go/spp\">HP Service Pack for ProLiant </a><strong>:</strong></strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\hp\\swpackages.</li>\n\t<li>Run the launch_hpsum.bat in the root of the ISO.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n\n<p><strong>NOTES: </strong>OPTIONS for in band enclosure flash:</p>\n\n<p><strong>Parameter</strong> &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<strong>Description</strong><br />\n-----------------------------------------------------------------------------<br />\n<strong>/h,/?&nbsp;</strong>&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;Displays command line usage help(dialog box)<br />\n<strong>/s </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Installs without user interaction</p>\n\n<p><strong>The following command&nbsp;is&nbsp;applicable only with /s:</strong><br />\n<strong>/f </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Allow a downgrade or reinstall if already up to date</p>\n\n<p>&nbsp;</p>\n\n<p><strong>Special installation instructions for single-domain environments:</strong><br />\n<br />\nIn a single domain configuration, I/O module A (top module) is connected to a SmartArray controller and I/O module B (bottom module) is unused. Even though the bottom I/O module is unused, both modules must have the same firmware version installed. Do the following to make sure that BOTH I/O modules are updated:</p>\n\n<ol>\n\t<li>Flash I/O module A of the first and all cascaded disk enclosures using the firmware upgrade executable.</li>\n\t<li>After I/O module A is flashed successfully in the disk enclosures, shut down and turn off the server.</li>\n\t<li>Remove A/C power to the first and all cascaded disk enclosures.</li>\n\t<li>Label all cables connected to I/O module A of the first and all cascaded disk enclosures and then disconnect all cables from the I/O modules.</li>\n\t<li>Swap the positions of the I/O modules in the enclosure.</li>\n\t<li>Reconnect the cables to the top I/O module (it used to be the bottom I/O module) in the enclosure, using the labels to ensure that all cabling is connected properly, in the same configuration as before.</li>\n\t<li>Turn on the storage enclosures and wait for them to complete their startup routines.</li>\n\t<li>Turn on the server.</li>\n\t<li>After the server startup procedure is complete, flash the top I/O module (the new I/O module A) of first and all cascaded disk enclosures using the firmware upgrade executable.</li>\n\t<li>After the I/O module is flashed successfully in the disk enclosures, power cycle the server to resume normal operation.</li>\n</ol>\n\n<p><strong>Installation Notes and Best Practices:</strong></p>\n\n<ul>\n\t<li>Before installing new firmware, review system requirements, enhancements list, fixes list, and other information in the firmware release notes, device QuickSpecs, and updated user documentation.</li>\n\t<li>Before installing new firmware, ensure that the system is stable and is not being reconfigured or changed in any way. If changes are in progress, monitor them and wait until they are completed before proceeding with the upgrade.</li>\n\t<li>Before installing new firmware, HP recommends creating a full backup of all data stored on the enclosure.</li>\n\t<li>When planning for a firmware update, schedule an appropriate time to perform an the update. Firmware updates must be performed during a system maintenance window, with all I/O to the system halted.</li>\n\t<li>After the installation process, verify system status in the software tools and confirm that the new firmware version is displayed as running on the enclosure.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong><strong>Smartアレイ構成のためのファームウェアのインストール手順：</strong></strong><br />\n<br /> ファームウェアはダウンロードされたファイルに含まれており、自己解凍型の実行可能モジュールです。コマンドラインコンソールかWindowsグラフィカルユーザーインターフェイスからこのモジュールを実行してください。</p>\n\n<p><strong>GUIオプション：</strong></p>\n\n<ol>\n\t<li>ダウンロードしたファームウェアパッケージを一時ディレクトリに置きます。</li>\n\t<li>Windowsエクスプローラーを使って、ダウンロードを含んでいるディレクトリに移動します。</li>\n\t<li>実行可能ファイルをダブルクリックします。</li>\n\t<li>画面上の指示に従います。</li>\n</ol>\n\n<p><strong>CLIオプション：</strong></p>\n\n<p>次のコマンドを入力して、Smartコンポーネントを実行します： CP0xxxxx.exe /s</p>\n\n<p><strong><a href=\"http://www.hp.com/go/spp\">HP Service Pack for ProLiant  </a></strong><strong>からHP Smart Update Managerを使用するには、以下の手順に従ってください。 </strong><strong>:</strong></p>\n\n<ul>\n\t<li>ディレクトリ\\SPP20xxxxx\\hp\\swpackagesにアップデートに必要なファームウェアをコピーします。</li>\n\t<li>ISOのルートにあるlaunch_hpsum.bat を実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n\n<p><strong>注: </strong>バンドエンクロージャーフラッシュのオプション：</p>\n\n<p><strong>パラメーター</strong>                      <strong>説明</strong><br /> -----------------------------------------------------------------------------<br /> <strong>/h,/? </strong>           コマンドラインの使用方法のヘルプを表示します(ダイアログボックス)<br /> <strong>/s  </strong>                ユーザーの操作なしでインストールします</p>\n\n<p><strong>/sを使用すると以下のコマンドが適用されます：</strong><br /> <strong>/f  </strong>               最新である場合、ダウングレードまたは再インストールできます</p>\n\n<p> </p>\n\n<p><strong>シングルドメイン環境での特別なインストール手順</strong><br />\n<br /> シングルドメインの構成では、I/OモジュールA（上側のモジュール）は、Smartアレイコントローラーに接続し、I/OモジュールB（下側のモジュール）は使用されません。たとえ下側のI/Oモジュールが使われない場合でも、両方のモジュールは同じファームウェアバージョンがインストールされていなければなりません。必ず両方のI/Oモジュールがアップデートされるように、以下を実行してください。</p>\n\n<ol>\n\t<li>実行可能なファームウェアアップグレードを使用して、最初のI/OモジュールAと全てのカスケードされたディスクエンクロージャーをフラッシュしてください。</li>\n\t<li>ディスクエンクロージャーでI/OモジュールAのフラッシュが成功した後、シャットダウンしてサーバーの電源を落とします。</li>\n\t<li>最初にA/C電源を、次にカスケードされた全てのディスクエンクロージャーを取り外します。</li>\n\t<li>最初のI/OモジュールAとカスケードされた全てのディスクエンクロージャーに接続されたケーブルにラベルを記載します。そして、I/Oモジュールからケーブルを取り外します。</li>\n\t<li>エンクロージャー内のI/Oモジュールの位置を交換します。</li>\n\t<li>以前の構成と同じように、全てのケーブル接続が正しいかラベルを確認して、エンクロージャー内の上側I/Oモジュール（下側I/Oモジュールとして使われていたもの）にケーブルを再接続します。</li>\n\t<li>ストレージエンクロージャーの電源を入れて、スタートアップルーチンの完了を待ちます。</li>\n\t<li>サーバーの電源を入れます。</li>\n\t<li>サーバーのスタートアッププロシジャーが完了後、実行可能なファームウェアアップグレードを使用して最初の上側I/Oモジュール（新しいI/OモジュールA）とカスケードされた全てのディスクエンクロージャーをフラッシュしてください。</li>\n\t<li>ディスクエンクロージャー内のI/Oモジュールのフラッシュが成功した後、通常の動作に戻すため、サーバーの電源を入れ直します。</li>\n</ol>\n\n<p><strong>インストールノートおよびベストプラクティス</strong></p>\n\n<ul>\n\t<li>ファームウェアをインストールする前に、システム要件、拡張リスト、修正リストおよびファームウェアリリースノート、デバイスのQuick Specs、他のユーザードキュメントの情報を確認してください。</li>\n\t<li>新しいファームウェアをインストールする前に、システムが安定していて、再設定中または変更中ではないことを確認してください。もし何らかの変更が処理中ならば、それらを監視し、処理が完了するまで待ってからアップグレードを始めてください。</li>\n\t<li>新しいファームウェアをインストールする前に、エンクロージャー上に保存されている全てのデータのフルバックアップを作成することをおすすめします。</li>\n\t<li>ファームウェアをアップグレードする場合、アップグレードを実行する適切な時間をスケジュールします。ファームウェアのアップグレードは、システムの全てのI/Oを停止して、システムをメンテナンスする期間内に行う必要があります。</li>\n\t<li>インストールプロセス後、ソフトウェアツールのシステムステータスの確認と新しいファームウェアバージョンがエンクロージャー上で実行中と表示されることを確認してください。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Windows (x64) 的 HP D2600/D2700 6Gb SAS 磁碟機櫃 ROM 更新元件"},{"lang":"en","x_late":"HP D2600/D2700 6Gb SAS Disk Enclosure ROM Flash Component for Windows (x64)"},{"lang":"ko","x_late":"Windows (x64)용 HP D2600/D2700 6Gb SAS 디스크 인클로저 ROM 플래시 구성 요소"},{"lang":"cn","x_late":"用于Windows (x64)的HP D2600/D2700 6Gb SAS磁盘机柜ROM刷新组件"},{"lang":"ja","x_late":"HP D2600/D2700 6Gb SASディスクエンクロージャーROMフラッシュコンポーネント for Windows (x64)"}],"prerequisites":{"required_diskspace":{"size_kb":"2"},"supported_devices":[{"id":"D2600 SAS AJ940A","target_guid":"","type":"msa"},{"id":"D2700 SAS AJ941A","target_guid":"","type":"msa"}],"supported_operating_systems":[{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"0","name":"Microsoft Windows Server 2008 x64","platform":"nt_x86-64","sr":"OEM"},{"edition":"core","major":"6","minor":"0","name":"Microsoft Windows Server 2008 x64 - Server Core Edition","platform":"nt_x86-64","sr":"OEM"},{"edition":"srvr","major":"6","minor":"0","name":"Microsoft Windows Server 2008 x64 - Server Edition","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-05-10T07:48:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>The following fix is added in this version:-</strong></p>\n\n<p>-Removed action over FAULT_SENSED bit due to incorrect algorithm.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>The following fix is added in this version:-</strong></p>\n\n<p>-Removed action over FAULT_SENSED bit due to incorrect algorithm.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"}],"sw_keys":[{"name":"D2700","sw_key_expectedpath":"firmware:QLOGIC"},{"name":"D2600","sw_key_expectedpath":"firmware:QLOGIC"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000960GXCLD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5210AG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304758434c44","Version":"HPG2"},{"DeviceName":"VK001920GXCGP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5210AG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304758434750","Version":"HPG2"},{"DeviceName":"VK003840GXCGQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5210AG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304758434751","Version":"HPG2"},{"DeviceName":"VK007680GXCGR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5210AG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-304758434752","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000960GXCLD, VK001920GXCGP, VK003840GXCGQ and VK007680GXCGR"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- VK000960GXCLD, VK001920GXCGP, VK003840GXCGQ and VK007680GXCGR Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"6563224","datemodified":"2021-08-13T14:20:18","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-4b4177239b-HPG2-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-4b4177239b-HPG2-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-4b4177239b-HPG2-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-4b4177239b-HPG2-2.1/CP049273.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-4b4177239b-HPG2-2.1/M5210AG2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-4b4177239b-HPG2-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-4b4177239b-HPG2-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-4b4177239b-HPG2-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-4b4177239b-HPG2-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049273.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049273.scexe"],"md5sum":"4ae3542a63e89af8af2bf78d6e632b37","name":"firmware-hdd-4b4177239b-HPG2-2.1.x86_64.rpm","release":"2021-08-13T14:08:04","revision":"0","sha1sum":"e3aaadc5fa3c15510be0fa03f9685b20802e7aae","size":"6MB","target_guids":["562340a5-304b-3030-3936-304758434c44","562340a5-304b-3130-3932-304758434750","562340a5-304b-3330-3834-304758434751","562340a5-304b-3730-3638-304758434752"],"type_of_change":"1","version":"HPG2"}],"id":{"product":"920be7efa67449a4b47e25f2db58a48e","version":"3c9b40b2406949feb955cb54b133bafa"},"installation":{"command":"CP043255.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK000960GXCLD, VK001920GXCGP, VK003840GXCGQ and VK007680GXCGR Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VK000960GXCLD","target_guid":"562340a5-304b-3030-3936-304758434c44","type":"sata"},{"id":"VK007680GXCGR","target_guid":"562340a5-304b-3730-3638-304758434752","type":"sata"},{"id":"VK001920GXCGP","target_guid":"562340a5-304b-3130-3932-304758434750","type":"sata"},{"id":"VK003840GXCGQ","target_guid":"562340a5-304b-3330-3834-304758434751","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-13T14:01:33","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK003840GXCGQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GXCGP","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK007680GXCGR","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GXCLD","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the iSCSI driver for the HPE Emulex 10/20GbE Server Adapters running under VMware vSphere 6.7."},{"lang":"ja","x_late":"この製品は、VMware vSphere 6.7上で動作するHPE Emulex 10/20GbEサーバーアダプターのためのiSCSIドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;12.0.1188.0.</p>\n"},{"lang":"ja","x_late":"<p>この製品には、ドライバーバージョン12.0.1188.0が含まれています。</p>\n"}],"files":[{"bytes":"3566056","datemodified":"2020-06-11T04:19:57","file_list":["/cp044544.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/elxiscsi-12.0.1188.0-1OEM.670.0.0.8169922.x86_64.vib","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/ELX-ESX-libelxima-8169922.so-12.0.1188.0.vib","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/doc/README.txt","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/doc/release_note_elxiscsi_12.0.1188.0-1OEM.670.0.0.8169922.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/index.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/vendor-index.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/metadata.zip","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/vib20/elxiscsi/EMU_bootbank_elxiscsi_12.0.1188.0-1OEM.670.0.0.8169922.vib","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/vib20/elx-esx-libelxima-8169922.so/ELX_bootbank_elx-esx-libelxima-8169922.so_12.0.1188.0-03.vib","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/metadata.zip/vmware.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/metadata.zip/bulletins/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/metadata.zip/vibs/elx-esx-libelxima-8169922.so-123123855.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/metadata.zip/vibs/elxiscsi-1258413454.xml"],"md5sum":"8072d670a52c8573702fa8b2af21fc31","name":"cp044544.zip","release":"2020-06-11T04:19:05","revision":"0","sha1sum":"c6a321999115f6ff6f29b278cac6601a7ec4f199","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb358b4ee","20a6e8e4-bf33-4c71-a6bf-d9ecadda42ba"],"type_of_change":"0","version":"2020.09.14","vib_list":[{"name":"elxiscsi","version":"12.0.1188.0-1OEM.670.0.0.8169922"},{"name":"elx-esx-libelxima-8169922.so","version":"12.0.1188.0-03"}]}],"id":{"product":"7fae0e3a1408427d859a7147aca14a11","version":"d6ee5259298e469584ecb1092196dca4"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバーにUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex 10/20GbE iSCSI Driver for VMware vSphere 6.7"},{"lang":"ja","x_late":"HPE Emulex 10/20GbE iSCSIドライバーfor VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"0722","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c220a","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c21d4","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c8144","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072215908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-11T01:46:43","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue ESXi lib naming convention in iscsi driver packages caused payload conflict for ESXi 6.7.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"elxiscsi:12.0.1188.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"elx-esx-libelxima-8169922.so:12.0.1188.0-03","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE QLogic FastLinQ 10/25/50 Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE QLogic FastLinQ 10/25/50 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"14884611","datemodified":"2021-08-11T14:37:47","file_list":["./etc/dracut.conf.d/fastlinq.conf","./lib/firmware/qed","./lib/firmware/qed/qed_init_values_zipped-8.50.18.0.bin","./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/qlgc-fastlinq","./lib/modules/5.3.18-22-default/updates/qlgc-fastlinq/qed.ko","./lib/modules/5.3.18-22-default/updates/qlgc-fastlinq/qede.ko","./lib/modules/5.3.18-22-default/updates/qlgc-fastlinq/qedf.ko","./lib/modules/5.3.18-22-default/updates/qlgc-fastlinq/qedi.ko","./lib/modules/5.3.18-22-default/updates/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/qlgc-fastlinq-kmp-default/component.xml"],"md5sum":"a976c68cddec8e303865b00e654caec0","name":"qlgc-fastlinq-kmp-default-8.55.14.0_k5.3.18_22-2.sles15sp2.x86_64.rpm","release":"2021-08-11T14:04:24","revision":"0","sha1sum":"a850113b7a51ad7dfcb926a5ff8fd394b324e89b","size":"14MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfc93be64"],"type_of_change":"0","version":"8.55.14.0-2"},{"bytes":"15319764","datemodified":"2021-08-11T14:35:45","file_list":["./etc/dracut.conf.d/fastlinq.conf","./lib/firmware/qed","./lib/firmware/qed/qed_init_values_zipped-8.50.18.0.bin","./lib/modules/5.3.18-57-default","./lib/modules/5.3.18-57-default/updates","./lib/modules/5.3.18-57-default/updates/qlgc-fastlinq","./lib/modules/5.3.18-57-default/updates/qlgc-fastlinq/qed.ko","./lib/modules/5.3.18-57-default/updates/qlgc-fastlinq/qede.ko","./lib/modules/5.3.18-57-default/updates/qlgc-fastlinq/qedf.ko","./lib/modules/5.3.18-57-default/updates/qlgc-fastlinq/qedi.ko","./lib/modules/5.3.18-57-default/updates/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/qlgc-fastlinq-kmp-default/component.xml"],"md5sum":"440f99f1cbd58db746792cfa37031a58","name":"qlgc-fastlinq-kmp-default-8.55.14.0_k5.3.18_57-2.sles15sp3.x86_64.rpm","release":"2021-08-11T14:04:24","revision":"0","sha1sum":"07b6a41ee6350635bd4496bd26dbbd68fc412122","size":"14MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfc93be64"],"type_of_change":"0","version":"8.55.14.0-2"}],"id":{"product":"39b3bcd8f8b243ad9879002d6ba846cc","version":"350d9cd09efc485583be5e2173bb24b4"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>Download README for any additional installation instructions.</p>\n"},{"lang":"ja","x_late":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>\n\n<p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>\n\n<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>\n\n<p> </p>\n\n<p>その他のインストール手順についてのREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE QLogic FastLinQ 10/25/50 GbE Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"SUSE Linux Enterprise Server 15用HPE QLogic FastLinQ 10/25/50 GbEドライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"8070","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021d","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021f","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0074","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770074","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0073","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770073","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-807015900220","type":"pci","ven":"1077"},{"dev":"8070","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8070159002bd","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0070","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770070","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0069","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770069","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0068","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770068","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0071","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770071","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0072","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770072","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021a","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021b","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0070","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770070","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0069","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770069","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0068","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770068","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0071","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770071","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0072","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770072","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0074","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770074","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0073","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770073","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><br />\nThis product now supports Suse Linux Enterprise Server 15 Service Pack 2</p>\n","latest_fixes_x_late":"<ul>\n\t<li>This product corrects an issue where the driver fails to load in NPAR mode when RoCE Data Center Quantized Congestion Notification (DCQCN) is enabled.</li>\n\t<li>This product corrects an issue ethernet data rate limiting unable on VFs.</li>\n\t<li>This product addresses a system crash seen when injecting a fw_assert on a NIC PF.</li>\n\t<li>This product addresses a system crash seen when limiting number of MSI-X interrupt vectors as requested for VFs</li>\n\t<li>This product addresses a system crash seen when unloading and reloading the RoCE driver only.</li>\n\t<li>This product addresses a system crash seen during multiple reboots of virtual machines using VFs and RDMA.</li>\n\t<li>This product addresses a the connection recover failed with heavy traffic</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>This product now supports&nbsp;SUSE Linux Enterprise Server 15 Service Pack 3</p>\n","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where the 10GbE Adapters having an DNS resolution issue on Kubernetes container-orchestration system</li>\n\t<li>This product addresses an issue where system crashes after PCIe error injection multiple times on HPE SDFlex system</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"qlgc-fastlinq-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"qlgc-fastlinq-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"qlgc-fastlinq-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"qlgc-fastlinq-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE 100Gb 1p OPA 860z FIO Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//HfiPcieGen3Loader_1.9.2.0.0.rom","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-24F01590021C","Version":"1.9.200"},{"DeviceName":"HPE 100Gb 1-Port OP101 QSFP28 x16 OPA Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//HfiPcieGen3Loader_1.9.2.0.0.rom","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-24F0159000E8","Version":"1.9.200"},{"DeviceName":"HPE 100Gb 1-Port OP101 QSFP28 x8 OPA Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//HfiPcieGen3Loader_1.9.2.0.0.rom","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-24F0159000E7","Version":"1.9.200"},{"DeviceName":"Intel Corporation Omni-Path HFI Silicon 100 Series [discrete]","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//HfiPcieGen3Loader_1.9.2.0.0.rom","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-24F0808624F0","Version":"1.9.200"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Intel OPA firmware on Linux Operating Systems."},{"lang":"ja","x_late":"このパッケージは、Linuxオペレーティングシステム上でHPE Intel OPAファームウェアをアップグレードするためのユーティリティとバイナリを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"background-color:#f5f5f5; color:#000000; font-family:verdana,helvetica,sans-serif; font-size:11px; height:94px; width:821px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td style=\"text-align:center\"><strong>OPA HFI Adapter Type</strong></td>\n\t\t\t<td style=\"text-align:center\"><strong>Firmware Version</strong></td>\n\t\t\t<td style=\"text-align:center\"><strong>SSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"text-align:center\">HPE 100Gb 1-Port OP101 QSFP28 x8 OPA Adapter</td>\n\t\t\t<td style=\"text-align:center\">1.9.2.0.0</td>\n\t\t\t<td style=\"text-align:center\">E7</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"text-align:center\">HPE 100Gb 1-Port OP101 QSFP28 x16 OPA Adapter&nbsp;</td>\n\t\t\t<td style=\"text-align:center\">1.9.2.0.0</td>\n\t\t\t<td style=\"text-align:center\">E8</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"text-align:center\">HPE Apollo 100Gb 1-port Intel Omni-Path Architecture 860z Mezzanine FIO Adapter</td>\n\t\t\t<td style=\"text-align:center\">1.9.2.0.0</td>\n\t\t\t<td style=\"text-align:center\">21C</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"261098","datemodified":"2019-05-29T01:30:14","file_list":["./usr/lib/x86_64-linux-gnu/firmware-nic-intel-opa-hfi-1.9.2-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-opa-hfi-1.9.2-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-opa-hfi-1.9.2-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-opa-hfi-1.9.2-1.1/CP039790.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-opa-hfi-1.9.2-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-opa-hfi-1.9.2-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-opa-hfi-1.9.2-1.1/nic_fw/CP039790.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-opa-hfi-1.9.2-1.1/nic_fw/HfiPcieGen3Loader_1.9.2.0.0.rom","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-opa-hfi-1.9.2-1.1/nic_fw/HfiPcieGen3_1.9.2.0.0.efi","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-opa-hfi-1.9.2-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-opa-hfi-1.9.2-1.1/nic_fw/hfi1_eprom","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-opa-hfi-1.9.2-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-opa-hfi-1.9.2-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP039790.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP039790.scexe"],"md5sum":"dbb5dda7ea0cf9a331fa54825f93339c","name":"firmware-nic-intel-opa-hfi-1.9.2-1.1.x86_64.rpm","release":"2019-05-29T06:31:08","revision":"0","sha1sum":"13d330be8564fc797e0d960310e24beb0746d090","size":"254KB","target_guids":["a6b1a447-382a-5a4f-8086-24F01590021C","a6b1a447-382a-5a4f-8086-24F0159000E8","a6b1a447-382a-5a4f-8086-24F0159000E7","a6b1a447-382a-5a4f-8086-24F0808624F0"],"type_of_change":"1","version":"1.9.2"}],"id":{"product":"7943f29050984f1f850b2530e1fd78f4","version":"91282beb581841a9a0428991925b27bd"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Updating firmware with rpm installed:</strong></p>\n\n<ul>\n\t<li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li>\n\t<li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li>\n\t<li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li>\n</ul>\n\n<p><strong>Updating firmware without installing rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li>\n\t<li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Intel OPA adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"24F0","subdev":"021C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-24f01590021c","type":"pci","ven":"8086"},{"dev":"24F0","subdev":"00E8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-24f0159000e8","type":"pci","ven":"8086"},{"dev":"24F0","subdev":"00E7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-24f0159000e7","type":"pci","ven":"8086"},{"dev":"24f0","subdev":"24f0","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-24f0808624f0","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-06-08T09:56:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Changes and New Features in version 1.8.1.0.0 :</strong></p>\n\n<ul>\n\t<li>Added hfi1_eprom <strong>v10_8_0_0_13.</strong></li>\n\t<li>Loader ROM <strong>HfiPcieGen3Loader_1.8.1.0.0.rom</strong> and driver EFI <strong>HfiPcieGen3_1.8.1.0.0.efi</strong> were added.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>Changes and New Features in version 1.9.2:</strong></p>\n\n<ul>\n\t<li>Added hfi1_eprom <strong>v10_9_2_0_0.</strong></li>\n\t<li>Loader ROM <strong>HfiPcieGen3Loader_1.9.2.0.0.rom</strong> and driver EFI <strong>HfiPcieGen3_1.9.2.0.0.efi </strong>were added.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Following issues have been resolved in version 1.9.2:</strong></p>\n\n<ul>\n\t<li>Due to a SLES 15 kernel setting, hfi1_eprom cannot work while the HFI driver is loaded. The tool and driver are mutually exclusive.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"Intel_OPA_HFI","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MR000240GWFLU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3234-304757464c55","Version":"HPGG"},{"DeviceName":"MR000480GWFLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3438-304757464c56","Version":"HPGG"},{"DeviceName":"VR000480GWFMD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3438-304757464d44","Version":"HPGG"},{"DeviceName":"MR000960GWFMA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3936-304757464d41","Version":"HPGG"},{"DeviceName":"VR000960GWFME","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3936-304757464d45","Version":"HPGG"},{"DeviceName":"MR001920GWFMB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3130-3932-304757464d42","Version":"HPGG"},{"DeviceName":"VR001920GWFMC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3130-3932-304757464d43","Version":"HPGG"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MR000240GWFLU, MR000480GWFLV, VR000480GWFMD, MR000960GWFMA, VR000960GWFME, MR001920GWFMB and VR001920GWFMC Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：MR000240GWFLU、MR000480GWFLV、VR000480GWFMD、MR000960GWFMA、VR000960GWFME、MR001920GWFMB VR001920GWFMC ドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MR000240GWFLU, MR000480GWFLV, VR000480GWFMD, MR000960GWFMA, VR000960GWFME, MR001920GWFMB&nbsp;and VR001920GWFMC Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGG<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGE<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPGE</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5036658","datemodified":"2021-07-23T08:44:12","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-9196d4f720-HPGG-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-9196d4f720-HPGG-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-9196d4f720-HPGG-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9196d4f720-HPGG-2.1/CP048184.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-9196d4f720-HPGG-2.1/M5100MGG.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-9196d4f720-HPGG-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9196d4f720-HPGG-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-9196d4f720-HPGG-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-9196d4f720-HPGG-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048184.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048184.scexe"],"md5sum":"e838eefbcb0ac0ac8cb8a7a370fd0c3f","name":"firmware-hdd-9196d4f720-HPGG-2.1.x86_64.rpm","release":"2021-07-23T08:32:08","revision":"0","sha1sum":"cde1b8ed507d325aa568a88f2cff7f95b22f6d13","size":"4MB","target_guids":["4d2340a5-3052-3030-3234-304757464c55","4d2340a5-3052-3030-3438-304757464c56","562340a5-3052-3030-3438-304757464d44","4d2340a5-3052-3030-3936-304757464d41","562340a5-3052-3030-3936-304757464d45","4d2340a5-3052-3130-3932-304757464d42","562340a5-3052-3130-3932-304757464d43"],"type_of_change":"1","version":"HPGG"}],"id":{"product":"a6840b5d0ec24ee78bf7a78ec26db476","version":"231cd2df5396414980da86fafb6370b9"},"installation":{"command":"CP041316.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/jp/servers/spp_dl\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MR000240GWFLU, MR000480GWFLV, VR000480GWFMD, MR000960GWFMA, VR000960GWFME, MR001920GWFMB and VR001920GWFMC Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MR000240GWFLU、MR000480GWFLV、VR000480GWFMD、MR000960GWFMA、VR000960GWFME、MR001920GWFMB、およびVR001920GWFMCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MR001920GWFMB","target_guid":"4d2340a5-3052-3130-3932-304757464d42","type":"sata"},{"id":"VR001920GWFMC","target_guid":"562340a5-3052-3130-3932-304757464d43","type":"sata"},{"id":"MR000240GWFLU","target_guid":"4d2340a5-3052-3030-3234-304757464c55","type":"sata"},{"id":"MR000480GWFLV","target_guid":"4d2340a5-3052-3030-3438-304757464c56","type":"sata"},{"id":"VR000480GWFMD","target_guid":"562340a5-3052-3030-3438-304757464d44","type":"sata"},{"id":"MR000960GWFMA","target_guid":"4d2340a5-3052-3030-3936-304757464d41","type":"sata"},{"id":"VR000960GWFME","target_guid":"562340a5-3052-3030-3936-304757464d45","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T20:50:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Improvements to Product Quality and Reliability.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MR000480GWFLV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MR000960GWFMA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VR001920GWFMC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VR000960GWFME","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MR001920GWFMB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VR000480GWFMD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MR000240GWFLU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO001600KWZQP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173500HPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b575a5150","Version":"HPK5"},{"DeviceName":"MO003200KWZQQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173500HPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b575a5151","Version":"HPK5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MO001600KWZQP and MO003200KWZQQ"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MO001600KWZQPおよびMO003200KWZQQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online NVMe SSD Flash Component for VMware ESXi -&nbsp;MO001600KWZQP and MO003200KWZQQ Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPK5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPK3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong>&nbsp;</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"25233064","datemodified":"2021-08-27T04:42:23","file_list":["/CP048472_BUILD_1.data","/CP048472.vmexe","/CP048472.vmexe64","/CP048472.vmfile","/CP048472_VMw.zip","/CP048472.xml","/payload.json","/CP048472_VMw.zip/index.xml","/CP048472_VMw.zip/vendor-index.xml","/CP048472_VMw.zip/metadata.zip","/CP048472_VMw.zip/vib20/CP048472/HPE_bootbank_CP048472_HPK5.1-7.0.0.15843807.vib","/CP048472_VMw.zip/metadata.zip/vendor-index.xml","/CP048472_VMw.zip/metadata.zip/vmware.xml","/CP048472_VMw.zip/metadata.zip/vibs/CP048472-6073239970384941838.xml","/CP048472_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048472_HPK5.1-7.0.0.15843807.xml"],"md5sum":"9f6895e9325a87c1871f20c725ed5b83","name":"CP048472.zip","release":"2021-08-27T04:37:35","revision":"0","sha1sum":"64b0cc9c3946908968d9525f3bed055674de534f","size":"24MB","target_guids":["4d2340a5-304f-3130-3630-304b575a5150","4d2340a5-304f-3330-3230-304b575a5151"],"type_of_change":"2","version":"HPK5","vib_list":[{"name":"CP048472","version":"HPK5.1-7.0.0.15843807"}]}],"id":{"product":"bb888c4588ea4d4989702d85035e6fce","version":"0583221447974eefb08fe24dcf0c46b2"},"installation":{"command":"CP040631.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします。</li>\n\t<li>CPXXXXXX.vmexe(ESXi 6.7 &以前のバージョン)およびCPXXXXXX.vmexe64(ESXi 7.0)は、次のコマンドを使用して実行可能です:</li>\n</ul>\n\n<p>             chmod x CPXXXXXX.vmexe    または    chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPXXXXXX.vmexe(または)./CPXXXXXX.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi  - MO001600KWZQP and MO003200KWZQQ Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi  - MO001600KWZQPおよびMO003200KWZQQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MO003200KWZQQ","target_guid":"4d2340a5-304f-3330-3230-304b575a5151","type":"nvme"},{"id":"MO001600KWZQP","target_guid":"4d2340a5-304f-3130-3630-304b575a5150","type":"nvme"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T16:45:13","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MO003200KWZQQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO001600KWZQP","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000JFJTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGNSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-304a464a5448","Version":"HPD4"},{"DeviceName":"MM002000JWCNF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGNSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304d-3230-3030-304a57434e46","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MM1000JFJTH and MM002000JWCNF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MM1000JFJTH and MM002000JWCNF Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5424949","datemodified":"2021-07-23T07:58:18","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD4-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD4-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD4-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD4-2.1/CP048181.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD4-2.1/SAVGNSD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD4-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD4-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD4-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD4-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048181.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048181.scexe"],"md5sum":"de642dd2c520c434af7f85ed1983ef8d","name":"firmware-hdd-fa46c607d6-HPD4-2.1.x86_64.rpm","release":"2021-07-23T07:46:05","revision":"0","sha1sum":"eedb7c7d2a6a71049720e228aafe97d4d039e415","size":"5MB","target_guids":["002340a5-4d00-314d-3030-304a464a5448","4d2340a5-304d-3230-3030-304a57434e46"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"aedaa041caed4345872545de3f1efa40","version":"a01a176831b54244a95df145f1f7ce84"},"installation":{"command":"CP040294.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MM1000JFJTH and MM002000JWCNF Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MM1000JFJTH","target_guid":"002340a5-4d00-314d-3030-304a464a5448","type":"sas"},{"id":"MM002000JWCNF","target_guid":"4d2340a5-304d-3230-3030-304a57434e46","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T20:41:08","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MM002000JWCNF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MM1000JFJTH","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the drivers for the HPE QLogic FastLinQ 10/25/50 GbE Server Adapters for Microsoft Windows Server 2016, Microsoft Windows Server 2019 and Microsoft Windows Server 2022."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This component contains the following drivers:</p>\n\n<ul>\n\t<li>Marvell Windows FastLinQ Ethernet VBD, 8.58.16.0</li>\n\t<li>Marvell Windows FastLinQ Ethernet VBD Client, 8.58.12.0&nbsp;</li>\n\t<li>Marvell Windows FCoE Offload Driver, 8.58.1.0</li>\n\t<li>Marvell Windows FCoE Crash-dump Driver, 8.58.1.0</li>\n\t<li>Marvell Windows iSCSI Crash-dump Driver, 8.58.1.0</li>\n\t<li>Marvell Windows iSCSI Offload Driver, 8.58.1.0</li>\n</ul>\n"}],"files":[{"bytes":"3502928","datemodified":"2021-08-11T06:25:52","file_list":["cp047061.xml","cpqsetup.exe","cp_data.xml","install.xml","qefcdo.sys","qefcdo_release.txt","qefcoe.cat","qefcoe.inf","qefcoe.sys","qefcoeco.dll","qefcoe_release.txt","qeiscdo.sys","qeiscdo_release.txt","qend.cat","qend.inf","qend.man","qenda.sys","qeois.cat","qeois.inf","qeois.sys","qeoisco.dll","qeois_release.txt","qevbd.cat","qevbd.inf","qevbda.sys","QLInstaller.dll","slipstream.zip"],"md5sum":"854ae0a5ddb074bcb53f039cf3c8b5ae","name":"cp047061.exe","release":"2021-08-11T06:09:07","revision":"0","sha1sum":"4292053036038583d196303c310cc58ece6c6961","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4b661f45"],"type_of_change":"0","version":"8.58.16.0"}],"id":{"product":"ff242e39c275472185612592300114ce","version":"defcba56c8804c769abd300c2194b2fe"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic FastLinQ 10/25/50 GbE Drivers for Windows Server x64 Editions"},{"lang":"ja","x_late":"Windows Server x64 Edition用HPE QLogic FastLinQ 10/25/50 GbEドライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_devices":[{"dev":"8070","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021d","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021f","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-807015900220","type":"pci","ven":"1077"},{"dev":"8070","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8070159002bd","type":"pci","ven":"1077"},{"dev":"8090","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8090159002bd","type":"pci","ven":"1077"},{"dev":"8090","subdev":"02BF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8090159002bf","type":"pci","ven":"1077"},{"dev":"8090","subdev":"02BE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8090159002be","type":"pci","ven":"1077"},{"dev":"8090","subdev":"02C0","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8090159002c0","type":"pci","ven":"1077"},{"dev":"8080","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80801590021f","type":"pci","ven":"1077"},{"dev":"8084","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80841590021f","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-809015900220","type":"pci","ven":"1077"},{"dev":"8090","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80901590021d","type":"pci","ven":"1077"},{"dev":"8090","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80901590021f","type":"pci","ven":"1077"},{"dev":"8080","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80801590021a","type":"pci","ven":"1077"},{"dev":"8080","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80801590021b","type":"pci","ven":"1077"},{"dev":"8084","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80841590021a","type":"pci","ven":"1077"},{"dev":"8084","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80841590021b","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021a","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021b","type":"pci","ven":"1077"},{"dev":"8090","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80901590021a","type":"pci","ven":"1077"},{"dev":"8090","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80901590021b","type":"pci","ven":"1077"},{"dev":"8090","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80901590021b","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product addresses a issue about UMCE error on 621SFP28 Adapter</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports Microsoft Windows Server 2022.</p>\n","curr_fixes_x_late":"<ul>\n\t<li>This product correct an issue where RoCE+L2 traffic on MOS in NPAR mode</li>\n\t<li>This product correct an issue where transmitting under heavy PAUSE/Priority-based Flow Control (PFC)</li>\n\t<li>This product correct an issue where turning off VMs while VF RDMA traffic is running</li>\n\t<li>This product correct an issue where yellow bang while running VF RoCE traffic with overnight switch port.</li>\n\t<li>This product correct an issue where installing dirvers with iSCSI enumerated.<br />\n\t&nbsp;</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"qevbda.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000JVYYV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMPN6SD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a56595956","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB6000JVYYV"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB6000JVYYV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp; MB6000JVYYV Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"17578189","datemodified":"2021-08-27T04:27:40","file_list":["/CP048379_BUILD_2.data","/CP048379.vmexe","/CP048379.vmexe64","/CP048379.vmfile","/CP048379_VMw.zip","/CP048379.xml","/payload.json","/CP048379_VMw.zip/index.xml","/CP048379_VMw.zip/vendor-index.xml","/CP048379_VMw.zip/metadata.zip","/CP048379_VMw.zip/vib20/CP048379/HPE_bootbank_CP048379_HPD2.2-7.0.0.15843807.vib","/CP048379_VMw.zip/metadata.zip/vendor-index.xml","/CP048379_VMw.zip/metadata.zip/vmware.xml","/CP048379_VMw.zip/metadata.zip/vibs/CP048379-5268119834730916793.xml","/CP048379_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048379_HPD2.2-7.0.0.15843807.xml"],"md5sum":"056ae73cbb235fcf1cc63293d242ea8e","name":"CP048379.zip","release":"2021-08-27T04:23:03","revision":"0","sha1sum":"72a43ff52949fea860d4ef9679d05ddecce6f271","size":"16MB","target_guids":["002340a5-4d00-3642-3030-304a56595956"],"type_of_change":"1","version":"HPD2","vib_list":[{"name":"CP048379","version":"HPD2.2-7.0.0.15843807"}]}],"id":{"product":"ecd26cd8b6e9412ba22bff66e6f6bbbe","version":"1f173493e5ad4232bf84b2dac8b9f444"},"installation":{"command":"CP040534.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB6000JVYYV Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB6000JVYYVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB6000JVYYV","target_guid":"002340a5-4d00-3642-3030-304a56595956","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T07:49:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000JVYYV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ED6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e52","Version":"HPD6"},{"DeviceName":"EG002400JWJNT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ED6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e54","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG001800JWJNR and EG002400JWJNT"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EG001800JWJNRおよびEG002400JWJNT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG001800JWJNR and EG002400JWJNT&nbsp;Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"6114974","datemodified":"2021-07-23T08:31:48","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPD6-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPD6-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPD6-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPD6-2.1/CP048074.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPD6-2.1/SSKYBT512ED6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPD6-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPD6-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPD6-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPD6-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048074.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048074.scexe"],"md5sum":"e63ac837af732d59dd91e13fbd685c43","name":"firmware-hdd-b1c9eaf74c-HPD6-2.1.x86_64.rpm","release":"2021-07-23T08:18:23","revision":"0","sha1sum":"d6f169585440342aaf25ca152a47d2be5840130f","size":"5MB","target_guids":["452340a5-3047-3130-3830-304a574a4e52","452340a5-3047-3230-3430-304a574a4e54"],"type_of_change":"1","version":"HPD6"}],"id":{"product":"9955e8989d3a49ccb377a1c01a7b8a6c","version":"51f64f5f6595400f9178bb4a62c0765a"},"installation":{"command":"CP041696.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64)  - EG001800JWJNR and EG002400JWJNT Drives"},{"lang":"ja","x_late":"オンラインHDD/SDDフラッシュコンポーネント for Linux (x64) - EG001800JWJNRおよびEG002400JWJNTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EG001800JWJNR","target_guid":"452340a5-3047-3130-3830-304a574a4e52","type":"sas"},{"id":"EG002400JWJNT","target_guid":"452340a5-3047-3230-3430-304a574a4e54","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-22T16:16:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG002400JWJNT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG001800JWJNR","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK007680GWSXN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M52008G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-30475753584e","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: VK007680GWSXN Drive"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：VK007680GWSXNドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;VK007680GWSXN&nbsp;Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5007880","datemodified":"2021-07-23T08:56:25","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG3-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG3-2.1/CP048191.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG3-2.1/M52008G3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG3-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048191.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048191.scexe"],"md5sum":"9eab53f756bc4ab4edc0798ad0c0ed27","name":"firmware-hdd-b460823f70-HPG3-2.1.x86_64.rpm","release":"2021-07-23T08:43:19","revision":"0","sha1sum":"292d9ae86684c04e0980665ad4842015ea782071","size":"4MB","target_guids":["562340a5-304b-3730-3638-30475753584e"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"0c319cd0bae843d891d1e9696a4b873b","version":"2545ec4bb8694330bcd38b4a2eca9b76"},"installation":{"command":"CP040780.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/jp/servers/spp_dl\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK007680GWSXN Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VK007680GWSXNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VK007680GWSXN","target_guid":"562340a5-304b-3730-3638-30475753584e","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T10:17:05","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Improved Product Quality and Reliability. Changed Cap Charge Timeout to 14 seconds from 4 seconds to provide additional time for cap charge in marginal power environment.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK007680GWSXN","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH0300JDXBA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SXD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3330-304a44584241","Version":"HPD5"},{"DeviceName":"EH0450JDXBB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SXD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3435-304a44584242","Version":"HPD5"},{"DeviceName":"EH0600JDXBC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SXD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3630-304a44584243","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EH0300JDXBA, EH0450JDXBB, and EH0600JDXBC"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： EH0300JDXBA、EH0450JDXBB、およびEH0600JDXBC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EH0300JDXBA, EH0450JDXBB&nbsp;and EH0600JDXBC Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features</strong>:</p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp; &nbsp;</strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4769108","datemodified":"2021-07-23T08:17:57","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-1cbab97ff0-HPD5-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-1cbab97ff0-HPD5-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-1cbab97ff0-HPD5-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-1cbab97ff0-HPD5-8.1/CP048087.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-1cbab97ff0-HPD5-8.1/TA13SXD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-1cbab97ff0-HPD5-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-1cbab97ff0-HPD5-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-1cbab97ff0-HPD5-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-1cbab97ff0-HPD5-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048087.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048087.scexe"],"md5sum":"0170a560cd27136476dffe51cad77bab","name":"firmware-hdd-1cbab97ff0-HPD5-8.1.x86_64.rpm","release":"2021-07-23T08:05:10","revision":"0","sha1sum":"e6a6fb91e7a2d5659c457a9e4a085e537177b705","size":"4MB","target_guids":["002340a5-4500-3048-3330-304a44584241","002340a5-4500-3048-3435-304a44584242","002340a5-4500-3048-3630-304a44584243"],"type_of_change":"1","version":"HPD5"}],"id":{"product":"8c2e806c31134d5f896832d57e01f96c","version":"f5443d165b6c4c5592a820a5765040fc"},"installation":{"command":"CP040282.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EH0300JDXBA, EH0450JDXBB and EH0600JDXBC Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux(x64) - EH0300JDXBA、EH0450JDXBBおよびEH0600JDXBCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EH0300JDXBA","target_guid":"002340a5-4500-3048-3330-304a44584241","type":"sas"},{"id":"EH0450JDXBB","target_guid":"002340a5-4500-3048-3435-304a44584242","type":"sas"},{"id":"EH0600JDXBC","target_guid":"002340a5-4500-3048-3630-304a44584243","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T11:26:55","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH0450JDXBB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0300JDXBA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0600JDXBC","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"nmlx4 is the low level driver implementation for the ConnectX®-3 and ConnectX®-3 Pro adapters for VMware ESXi 6.5 Mellanox Ethernet Adapters."},{"lang":"ja","x_late":"nmlx4は、VMware ESXi 6.5 Mellanoxイーサーネットアダプター用ConnectX®-3およびConnectX®-3 Proアダプターの低レベルドライバー実装です。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1262418","datemodified":"2021-04-06T13:45:16","file_list":["/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-17262032.zip","/cp047457.xml","/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-17262032.zip/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-offline_bundle-17262032.zip","/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-17262032.zip/doc/README.txt","/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-17262032.zip/doc/release_note_nmlx4-rdma_3.19.70.1-1OEM.670.0.0.8169922.pdf","/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-17262032.zip/doc/release_note_nmlx4-en_3.19.70.1-1OEM.670.0.0.8169922.pdf","/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-17262032.zip/doc/release_note_nmlx4-core_3.19.70.1-1OEM.670.0.0.8169922.pdf","/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-17262032.zip/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-offline_bundle-17262032.zip/index.xml","/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-17262032.zip/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-offline_bundle-17262032.zip/vendor-index.xml","/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-17262032.zip/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-offline_bundle-17262032.zip/metadata.zip","/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-17262032.zip/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-offline_bundle-17262032.zip/vib20/nmlx4-en/MEL_bootbank_nmlx4-en_3.19.70.1-1OEM.670.0.0.8169922.vib","/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-17262032.zip/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-offline_bundle-17262032.zip/vib20/nmlx4-rdma/MEL_bootbank_nmlx4-rdma_3.19.70.1-1OEM.670.0.0.8169922.vib","/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-17262032.zip/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-offline_bundle-17262032.zip/vib20/nmlx4-core/MEL_bootbank_nmlx4-core_3.19.70.1-1OEM.670.0.0.8169922.vib","/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-17262032.zip/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-offline_bundle-17262032.zip/metadata.zip/vendor-index.xml","/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-17262032.zip/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-offline_bundle-17262032.zip/metadata.zip/vmware.xml","/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-17262032.zip/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-offline_bundle-17262032.zip/metadata.zip/vibs/nmlx4-en--1135219844456576062.xml","/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-17262032.zip/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-offline_bundle-17262032.zip/metadata.zip/vibs/nmlx4-rdma--132306099509880181.xml","/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-17262032.zip/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-offline_bundle-17262032.zip/metadata.zip/vibs/nmlx4-core-9013284204170896708.xml","/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-17262032.zip/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-offline_bundle-17262032.zip/metadata.zip/bulletins/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922.xml"],"md5sum":"70ed6012816884c664835dcc2d1f40e8","name":"cp047457.zip","release":"2021-04-06T13:42:05","revision":"0","sha1sum":"85dea0f3ebe77b454a0c7561795e32ce632e80de","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec0427da2e","20a6e8e4-bf33-4c71-a6bf-d9ec34a24f7b","20a6e8e4-bf33-4c71-a6bf-d9ec50f64a40","20a6e8e4-bf33-4c71-a6bf-d9ec9f71a861"],"type_of_change":"1","version":"2020.11.11","vib_list":[{"name":"nmlx4-en","version":"3.19.70.1-1OEM.670.0.0.8169922"},{"name":"nmlx4-rdma","version":"3.19.70.1-1OEM.670.0.0.8169922"},{"name":"nmlx4-core","version":"3.19.70.1-1OEM.670.0.0.8169922"}]}],"id":{"product":"7b0103ddf3b44215b7f92f0c298c391f","version":"bb64cadfd33e4a0887eedcf668295f24"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Remote Online:&nbsp;</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the HPE USB Key Creator Utility.&nbsp;</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux .</li>\n\t<li>cd /SPP20xxxxx/ and launch SUM&nbsp;(launch_sum.bat for Windows and ./launch_sum.sh for Linux).</li>\n\t<li>Select &quot;Baseline Library&quot; and wait for the Baseline inventory to complete.</li>\n\t<li>Select &quot;Nodes&quot; from the &quot;Smart Update Manager x.x.x&quot; drop down.</li>\n\t<li>Click, &quot;Add Node&quot;.\n\t<ul>\n\t\t<li>If adding a Gen9 server,\n\t\t<ul>\n\t\t\t<li>Provide IP address of the ESXi host.</li>\n\t\t\t<li>Enter&nbsp;the ESXi host credentials (root or administrator username and password)&nbsp;</li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>If adding a Gen10 and above server,\n\t\t<ul>\n\t\t\t<li>Provide iLO IP address of the ESXi host server.</li>\n\t\t\t<li>Enter the iLO credentials of the ESXi host server.</li>\n\t\t</ul>\n\t\t</li>\n\t</ul>\n\t</li>\n\t<li>Follow&nbsp;Smart Update Manager Steps and complete the driver update.&nbsp;</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware VUM or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>リモートオンライン: </strong></p>\n\n<ol>\n\t<li>HPE USB Key Creator Utilityを使用して、SPPをUSBキーにコピーします。 </li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。</li>\n\t<li>cd /SPP20xxxxx およびSUMを起動します。（Windowsの場合はlaunch_sum.bat、Linuxの場合は./launch_sum.sh）</li>\n\t<li>\"ベースラインライブラリ\"を選択し、ベースラインインベントリが完了するのを待ちます。</li>\n\t<li>\"Smart Update Manager x.x.x\"ドロップダウンから\"ノード\"を選択します。</li>\n\t<li>\"ノードの追加\"をクリックします。\n\t<ul>\n\t\t<li>Gen9サーバーを追加する場合、\n\t\t<ul>\n\t\t\t<li>ESXiホストのIPアドレスを提供します。</li>\n\t\t\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します </li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>Gen10以降のサーバーを追加する場合、\n\t\t<ul>\n\t\t\t<li>ESXiホストサーバーのiLO IPアドレスを提供します。</li>\n\t\t\t<li>ESXiホストサーバーのiLO認証情報を入力します。</li>\n\t\t</ul>\n\t\t</li>\n\t</ul>\n\t</li>\n\t<li>Smart Update Managerの指示に従い、ドライバーのアップデートを完了します。 </li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li>\n\t<li>オフラインバンドルをインストールするために、VMware VUMまたはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"nmlx4_en Driver Component for VMware 7.0"},{"lang":"ja","x_late":"nmlx4_enドライバーコンポーネント for VMware 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"1003","subdev":"1777","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1003103c1777","type":"pci","ven":"15B3"},{"dev":"1003","subdev":"18CF","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1003103c18cf","type":"pci","ven":"15B3"},{"dev":"1003","subdev":"18D6","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1003103c18d6","type":"pci","ven":"15B3"},{"dev":"1003","subdev":"18CD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1003103c18cd","type":"pci","ven":"15B3"},{"dev":"1003","subdev":"18CE","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1003103c18ce","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-06T11:34:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Changes and New Features in version 3.19.70.1:</strong></p>\n\n<ul>\n\t<li>Resolved an issue that caused the network adapter traffic to stop.</li>\n\t<li>Fixed an internal multicast loopback issue that broke LACP(Link Aggregation Control Protocol) bonding protocol.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>Changes and New Features in version 3.19.70.1:</strong></p>\n\n<ul>\n\t<li>Resolved an issue that caused the network adapter traffic to stop.</li>\n\t<li>Fixed an internal multicast loopback issue that broke LACP(Link Aggregation Control Protocol) bonding protocol.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"","value":"HPE Apollo sx40 Server"}],"sw_keys":[{"name":"nmlx4-core:3.19.70.1-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"nmlx4-en:3.19.70.1-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"nmlx4-rdma:3.19.70.1-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"Mellanox-nmlx4:3.19.70.1-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver.component:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Blade Intel ixn 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Microsoft Windows Server 2019で動作しているHPE Blade Intel ixn 10 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1027328","datemodified":"2021-08-18T16:11:33","file_list":["cp049075.xml","cpqsetup.exe","cp_data.xml","install.xml","ixn68x64.cat","ixn68x64.din","ixn68x64.inf","ixn68x64.sys","ixnmsg.dll","nicdrvr.dll"],"md5sum":"6eb15db30e000b484554e14c812feea7","name":"cp049075.exe","release":"2021-08-18T15:57:19","revision":"0","sha1sum":"e2b6193d7f7a84cb0e0a734549f1689817243460","size":"0MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec619e0b4b"],"type_of_change":"0","version":"4.1.197.0"}],"id":{"product":"cad34a66b4fc4a06bf8a262ac99afab3","version":"295af7fd26214475a9270cb0398fd66f"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Intel ixn Driver for Windows Server 2019"},{"lang":"ja","x_late":"HPE Blade Intel ixnドライバー for Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-03T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product is updated to maintain compatibility with updated Windows installation library ixtmsg.dll.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports the&nbsp;HPE ProLiant BL660c Gen9 Server.&nbsp;</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"ixn68x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component updates the firmware on ProLiant Gen9 NVMe storage backplanes. "},{"lang":"ja","x_late":"このコンポーネントは、ProLiant Gen9 NVMe ストレージバックプレーンをアップデートします。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"1024097","datemodified":"2018-03-02T03:37:04","file_list":["/CP035161.vmexe","/CP035161.vmfile","/CP035161.xml","/README.txt"],"md5sum":"cc1f7c8c520ea366c1e9caca8fdf4b28","name":"CP035161.zip","release":"2018-03-02T09:34:04","revision":"0","sha1sum":"e9e3deeea769baa87e07e5a4d2c5748806bdcf27","size":"0MB","target_guids":[],"type_of_change":"0","version":"8.4","vib_list":[]}],"id":{"product":"2c10c37c94934b028d1c460ce9f457fb","version":"c6b29241292145d8af4d872005ebf538"},"installation":{"command":"cpqsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component requires that the CRU driver be loaded before the component can run.&nbsp;&nbsp;<br />\nThe minimum CRU version for 6.0 is 6.0.8.<br />\nThe minimum CRU version for&nbsp;6.5 is 6.5.8.<br />\n<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>SPP Offline mode boots a special Linux OS environment, thus the Linux Components are used, not the VMware Components</li>\n</ul>\n\n<p><br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Download the appropriate SPP</li>\n\t<li>Add the component to the SPP</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run SUM</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps to complete the firmware update</li>\n\t<li>Refer to the SPP documentation for detailed instructions at:&nbsp; <a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a></li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Component ( CPxxxxxx.zip) in a temporary directory</li>\n\t<li>From the same directory, unzip the Component:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>To perform the standalone installation, execute the command:<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>Follow the directions given by the Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、実行する前にCRUドライバーがロードされている必要があります。  <br />\n6.0の最小CRUバージョンは6.0.8です。<br />\n6.5の最小CRUバージョンは6.5.8です。<br />\n<br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMwareコンポーネントではなく、Linuxコンポーネントが用いられます</li>\n</ul>\n\n<p><br />\n<strong>リモートオンライン、コンポーネントはSUMでサポートされますが、まだSPPの一部ではありません:</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします</li>\n\t<li>SPPにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします</li>\n\t<li>SUMを実行</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します</li>\n\t<li>SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います</li>\n\t<li>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a></li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>コンポーネント (CPxxxxxx.zip)を一時ディレクトリに置きます</li>\n\t<li>同じディレクトリからコンポーネントをunzipします：<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>スタンドアロンのインストールを行うために、次のコマンドを実行します：<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>コンポーネントの指示に従います</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Flash Component for VMware - NVMe Backplane PIC Firmware "},{"lang":"ja","x_late":"VMware 用オンラインフラッシュコンポーネント - NVMeバックプレーンPICファームウェア "}],"prerequisites":{"required_diskspace":{"size_kb":"10000"},"supported_devices":[{"id":"NVMe Backplane","target_guid":"","type":"pic"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2018-03-28T12:53:39","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul style=\"list-style-type: square;\">\n\t<li>Updated to support Service Pack for ProLiant version 2017.07.0</li>\n</ul>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;<strong>Note:</strong>&nbsp;If&nbsp;version 8.4 was previously installed, then it is not necessary to upgrade to version 8.4 (C).</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added ESXi 6.7 OS support</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"}],"sw_keys":[{"name":"NVMePIC-Gen9","sw_key_expectedpath":"firmware:sd:nvmebackplane"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GWSSC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757535343","Version":"HPG3"},{"DeviceName":"MK000960GWSSD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757535344","Version":"HPG3"},{"DeviceName":"MK001920GWSSE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304757535345","Version":"HPG3"},{"DeviceName":"MK003840GWSSF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-304757535346","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MK000480GWSSC, MK000960GWSSD, MK001920GWSSE and MK003840GWSSF"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MK000480GWSSC、MK000960GWSSD、MK001920GWSSEおよびMK003840GWSSF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for&nbsp;Windows (x64)&nbsp;- MK000480GWSSC, MK000960GWSSD, MK001920GWSSE and MK003840GWSSF Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG2</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG2<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4459808","datemodified":"2021-07-25T20:57:22","file_list":["cp048654.xml","cpqsetup.exe","GSM883G3.rel","payload.json","setup.dll"],"md5sum":"e84d319cdd2d329efbea507d9544af0f","name":"cp048654.exe","release":"2021-07-25T20:49:04","revision":"0","sha1sum":"66f479ed48e2160f9b338cde87e2b0de85ecfbc5","size":"4MB","target_guids":["4d2340a5-304b-3030-3438-304757535343","4d2340a5-304b-3030-3936-304757535344","4d2340a5-304b-3130-3932-304757535345","4d2340a5-304b-3330-3834-304757535346"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"2a24f9ce00084650b7c1f83427a4e25f","version":"510b9d30680448ddb07494e1f9707bc3"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MK000480GWSSC, MK000960GWSSD, MK001920GWSSE and MK003840GWSSF Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows(x64)- MK000480GWSSC、 MK000960GWSSD、MK001920GWSSEおよびMK003840GWSSFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MK003840GWSSF","target_guid":"4d2340a5-304b-3330-3834-304757535346","type":"sata"},{"id":"MK001920GWSSE","target_guid":"4d2340a5-304b-3130-3932-304757535345","type":"sata"},{"id":"MK000960GWSSD","target_guid":"4d2340a5-304b-3030-3936-304757535344","type":"sata"},{"id":"MK000480GWSSC","target_guid":"4d2340a5-304b-3030-3438-304757535343","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T19:07:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK001920GWSSE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWSSC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWSSD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK003840GWSSF","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000GEFNA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRATG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304745464e41","Version":"HPG6"},{"DeviceName":"MB6000GEFNB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRATG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745464e42","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB4000GEFNA and MB6000GEFNB Drives "},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MB4000GEFNAおよびMB6000GEFNBドライブ "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB4000GEFNA and MB6000GEFNB Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp; &nbsp;</strong>None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"5321900","datemodified":"2021-07-23T07:21:24","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-40277d55d3-HPG6-10.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-40277d55d3-HPG6-10.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-40277d55d3-HPG6-10.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-40277d55d3-HPG6-10.1/CP048161.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-40277d55d3-HPG6-10.1/SMKRATG6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-40277d55d3-HPG6-10.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-40277d55d3-HPG6-10.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-40277d55d3-HPG6-10.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-40277d55d3-HPG6-10.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048161.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048161.scexe"],"md5sum":"5c7396086f53ce4e1a52c3da1fac6760","name":"firmware-hdd-40277d55d3-HPG6-10.1.x86_64.rpm","release":"2021-07-23T07:07:14","revision":"0","sha1sum":"fe92f620e71ae3248ecf36a6a21a60a0da4d6f6e","size":"5MB","target_guids":["002340a5-4d00-3442-3030-304745464e41","002340a5-4d00-3642-3030-304745464e42"],"type_of_change":"1","version":"HPG6"}],"id":{"product":"72599cd140dd4be0b9dbc3875c332654","version":"92e9d3545345490aab5cef5c34fb1ed0"},"installation":{"command":"CP040261.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB4000GEFNA and MB6000GEFNB Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB4000GEFNAおよびMB6000GEFNBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB4000GEFNA","target_guid":"002340a5-4d00-3442-3030-304745464e41","type":"sata"},{"id":"MB6000GEFNB","target_guid":"002340a5-4d00-3642-3030-304745464e42","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T19:10:54","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000GEFNA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB6000GEFNB","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG0600JETKA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SED8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3630-304a45544b41","Version":"HPD8"},{"DeviceName":"EG0900JETKB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SED8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3930-304a45544b42","Version":"HPD8"},{"DeviceName":"EG1200JETKC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SED8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3230-304a45544b43","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG0600JETKA, EG0900JETKB and EG1200JETKC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - EG0600JETKA,&nbsp;EG0900JETKB&nbsp;and&nbsp;EG1200JETKC Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"2916032","datemodified":"2021-07-24T06:29:02","file_list":["cp048485.xml","cpqsetup.exe","payload.json","setup.dll","TA14SED8.rel"],"md5sum":"5b0193dec9cdb00625a63a2cb3ea5d8c","name":"cp048485.exe","release":"2021-07-24T06:21:05","revision":"0","sha1sum":"6fe52a075eefd3c3ca53e5272d99cacc181fb27d","size":"2MB","target_guids":["002340a5-4500-3047-3630-304a45544b41","002340a5-4500-3047-3930-304a45544b42","002340a5-4500-3147-3230-304a45544b43"],"type_of_change":"1","version":"HPD8"}],"id":{"product":"696ee1f3634445c49a160d3bc3772307","version":"6cec8bd277a941e9899b572a64f027f3"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG0600JETKA, EG0900JETKB and EG1200JETKC Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EG0600JETKA、EG0900JETKB、およびEG1200JETKCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG1200JETKC","target_guid":"002340a5-4500-3147-3230-304a45544b43","type":"sas"},{"id":"EG0600JETKA","target_guid":"002340a5-4500-3047-3630-304a45544b41","type":"sas"},{"id":"EG0900JETKB","target_guid":"002340a5-4500-3047-3930-304a45544b42","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-14T07:49:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>A low-probability, high severity corner case of sustained outer-diameter activity with emergency power off when heads are at the outer diameter prevented heads from parking/latching properly on a few drives in the field.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG0900JETKB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG1200JETKC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0600JETKA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JWXKH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG08scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a57584b48","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB016000JWXKH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online HDD/SSD&nbsp;Flash Component for VMware ESXi - MB016000JWXKH&nbsp;Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"17635112","datemodified":"2021-08-27T18:26:43","file_list":["/CP049124_BUILD_1.data","/CP049124.vmexe","/CP049124.vmexe64","/CP049124.vmfile","/CP049124_VMw.zip","/CP049124.xml","/payload.json","/CP049124_VMw.zip/index.xml","/CP049124_VMw.zip/vendor-index.xml","/CP049124_VMw.zip/metadata.zip","/CP049124_VMw.zip/vib20/CP049124/HPE_bootbank_CP049124_HPD9.1-7.0.0.15843807.vib","/CP049124_VMw.zip/metadata.zip/vendor-index.xml","/CP049124_VMw.zip/metadata.zip/vmware.xml","/CP049124_VMw.zip/metadata.zip/vibs/CP049124--8377738557993626998.xml","/CP049124_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049124_HPD9.1-7.0.0.15843807.xml"],"md5sum":"0498e8d1e89fb7f644319d19f2a593d6","name":"CP049124.zip","release":"2021-08-27T18:22:03","revision":"0","sha1sum":"e51d03b3473ea90805b85fe9c9e0b65fbd349cef","size":"16MB","target_guids":["4d2340a5-3042-3631-3030-304a57584b48"],"type_of_change":"1","version":"HPD9","vib_list":[{"name":"CP049124","version":"HPD9.1-7.0.0.15843807"}]}],"id":{"product":"8a5f6b85a2a94dc58e5d42c516c7060a","version":"e72cd0a1a2554c49b874fb4c02d8a2cb"},"installation":{"command":"CP041025.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB016000JWXKH Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB016000JWXKH","target_guid":"4d2340a5-3042-3631-3030-304a57584b48","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T15:27:54","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This firmware&nbsp;revision corrects a rare situation where a Cryptographic Erase could result in random data instead of the expected deterministic zeros. This is judged as low severity because it does not compromise user data or security, but justifies the update to preclude potential security concerns. There are several items that reduce the probability of hangs and provide some minor performance improvements.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB016000JWXKH","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900217","languages":[{"lang":"fr","x_late":"Micrologiciel - Infrastructure Blade"},{"lang":"en","x_late":"Firmware - Blade Infrastructure"},{"lang":"cn","x_late":"固件 - 刀片式架构"},{"lang":"tw","x_late":"韌體 ─ 刀鋒型基礎架構"},{"lang":"de","x_late":"Firmware - Blade-Infrastruktur"},{"lang":"ko","x_late":"펌웨어 - 블레이드 인프라"},{"lang":"it","x_late":"Firmware - Infrastruttura Blade"},{"lang":"ja","x_late":"ファームウェア - ブレード インフラストラクチャ"},{"lang":"es","x_late":"Firmware - Infraestructura Blade"}]}],"description":[{"lang":"en","x_late":"This component contains the firmware image for HPE BladeSystem c-Class Virtual Connect modules. This firmware provides management capabilities for the HPE BladeSystem c-Class Virtual Connect modules. This component and its firmware can be used in the following scenarios: 1) in conjunction with the Smart Update Manager found in the HPE BladeSystem Online Firmware Bundle, the component can be used to deploy the firmware to the HPE BladeSystem c-Class Virtual Connect modules, and 2) firmware extracted from the component can be deployed using the Virtual Connect Support Utility for the HPE BladeSystem c-Class Virtual Connect modules."},{"lang":"ja","x_late":"このコンポーネントには、HPE BladeSystem c-Class バーチャルコネクトモジュールのファームウェアイメージが含まれています。このファームウェアは、HPE BladeSystem c-Class バーチャルコネクトモジュールの管理機能を提供します。このコンポーネントとそのファームウェアは、次のシナリオで使用できます：1) コンポーネントをHPE BladeSystemオンラインファームウェアバンドルにあるSmart Update Managerとともに使用することで、ファームウェアをHPE BladeSystem c-Classバーチャルコネクトモジュールに実装できる、および2) コンポーネントから展開したファームウェアを、HPE BladeSystem c-Classバーチャルコネクトモジュール対応のバーチャルコネクトサポートユーティリティを使用して実装できる。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[{"lang":"en","x_late":"<p>The 4.85&nbsp;version of HPE Virtual Connect Release Notes can be found in the in the following URL:&nbsp;<a href=\"http://www.hpe.com/info/vc/manuals\">http://www.hpe.com/info/vc/manuals</a></p>\n"}],"files":[{"bytes":"257797526","datemodified":"2020-07-20T02:59:35","file_list":["./usr/lib/x86_64-linux-gnu/firmware-vceth-4.85-1.1","./usr/lib/x86_64-linux-gnu/firmware-vceth-4.85-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-vceth-4.85-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-vceth-4.85-1.1/CP043331.xml","./usr/lib/x86_64-linux-gnu/firmware-vceth-4.85-1.1/HpsumCli","./usr/lib/x86_64-linux-gnu/firmware-vceth-4.85-1.1/PackageDesc.xml","./usr/lib/x86_64-linux-gnu/firmware-vceth-4.85-1.1/cp_data.xml","./usr/lib/x86_64-linux-gnu/firmware-vceth-4.85-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-vceth-4.85-1.1/setup","./usr/lib/x86_64-linux-gnu/firmware-vceth-4.85-1.1/vcfwall485.bin","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP043331.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP043331.scexe"],"md5sum":"a1b889c932cd07ff8ea69c6f1d27819a","name":"firmware-vceth-4.85-1.1.x86_64.rpm","release":"2020-07-20T02:42:05","revision":"0","sha1sum":"b846ba26deeafa3dfcc8c7ed593a26f18efa1cba","size":"245MB","target_guids":[],"type_of_change":"1","version":"4.85"}],"id":{"product":"f94dec5c06294dd898433cd8abf10b3a","version":"509893f2521f4f4595773fa96f988527"},"installation":{"command":"Entry.bsh","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":1500,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>This component and its firmware can be used in the following scenarios:</p>\n\n<ol>\n\t<li>\n\t<p>In conjunction with the Smart Update Manager found on the SPP, the component can be used to deploy the firmware to the HPE BladeSystem c-Class Virtual Connect module.</p>\n\t</li>\n\t<li>\n\t<p>Firmware extracted from the component can be deployed using the Virtual Connect Support Utility for the HPE BladeSystem c-Class Virtual Connect modules.</p>\n\t</li>\n</ol>\n\n<p><strong>Installation Notes for using the component with Smart Update Manager and SPP</strong></p>\n\n<ol>\n\t<li>Obtain the latest version of <a href=\"http://www.hpe.com/info/spp/download\">SPP</a>.</li>\n\t<li>Extract the contents of the SPP ISO, locate the directory, /usb, and run the hpusbkey.exe file.</li>\n\t<li>Place the SPP on a USB key using the USB Key Utility</li>\n\t<li>Place this version of the Virtual Connect firmware component in the directory, /hp/swpackages on the USB key.</li>\n\t<li>Place the USB key in a system which is on the same&nbsp;network as the HPE BladeSystem c-Class Virtual Connect module to be updated.</li>\n\t<li>Run &ldquo;launch_hpsum.bat/launch_hpsum.sh&rdquo; on the SPP from the USB key to launch the Smart Update Manager.</li>\n\t<li>Follow the GUI to install the firmware on the Virtual Connect module.</li>\n</ol>\n\n<p><strong>Installation Notes for using the firmware extracted from the component</strong></p>\n\n<ol>\n\t<li>\n\t<p>Extract the firmware binary out of the component.</p>\n\t</li>\n\t<li>\n\t<p>Place the firmware image file onto a system on the same network as the HPE BladeSystem c-Class Virtual Connect module.</p>\n\t</li>\n\t<li>\n\t<p>Start the Virtual Connect Support Utility and deploy the firmware.</p>\n\t</li>\n</ol>\n\n<p>HPE requires using the HPE BladeSystem c-Class Virtual Connect Support Utility version 1.15.0&nbsp;(or higher)&nbsp;to install the HPE VC FlexFabric-20/40 F8 version 4.85, HPE VC Flex-10/10D version&nbsp;4.85,&nbsp;HPE VC FlexFabric 10Gb/24-port version 4.85,&nbsp;HPE VC 8Gb 24-Port FC version 4.20, HPE VC 16Gb 24-Port FC version 4.20, and HPE VC 8Gb 20-Port FC version 2.25&nbsp;firmware. Please read the HPE BladeSystem c-Class Virtual Connect Support Utility release notes.<br />\n<br />\nPlease be advised of a serious issue that could cause network outage when upgrading directly from VC 2.xx release version to VC 4.85&nbsp;release in Multi-Enclosure environment. Please upgrade from VC 2.xx to VC 3.70 or VC 4.10 first and then upgrade from VC 3.70 or VC 4.10 to VC 4.50 then upgrade from VC 4.50&nbsp;to VC 4.85&nbsp;in a Multi-Enclosure setup.</p>\n\n<p>To update HPE VC 8Gb 24-Port FC module(s) from Virtual Connect firmware 4.31 or lower to Virtual Connect 4.85&nbsp;or higher, these module(s) must first be updated with either Virtual Connect firmware version 4.4x or version 4.50 (Recommended version is 4.50) before they can be updated with Virtual Connect 4.85&nbsp;or higher.</p>\n\n<p>The USB Key Utility is used to copy the SPP onto a portable USB key storage device.&nbsp; Please note that the latest version (v2.0.0.0)&nbsp;of the utility is now 64-bit only.&nbsp; If the 32-bit application is needed, please use version 1.8, however, this version will not work on an ISO image greater than 4GB.</p>\n\n<p><strong>Note: Please read the Important note section of the Release Notes for firmware upgrade instructions.</strong></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"HPE BladeSystem c-Class Virtual Connect 韌體，乙太網路加上 8Gb 20 埠及 8/16Gb 24 埠 FC Edition 元件 (適用於 Linux)"},{"lang":"en","x_late":"HPE BladeSystem c-Class Virtual Connect Firmware, Ethernet plus 8Gb 20-port and 8/16Gb 24-port FC Edition Component for Linux"},{"lang":"ko","x_late":"Linux용 HPE BladeSystem c-Class Virtual Connect 펌웨어, Ethernet plus 8Gb 20포트 및 8/16Gb 24포트 FC Edition 구성 요소"},{"lang":"cn","x_late":"HPE BladeSystem c-Class 虚拟连接固件，适用于 Linux 的 Ethernet plus 8Gb 20 端口和 8/16Gb 24端口 FC Edition 组件"},{"lang":"ja","x_late":"HPE BladeSystem c-Class Virtual Connectファームウェア、Ethernet plus 8 Gb 20ポートおよび8/16 Gb 24ポートFC Editionコンポーネント for Linux"}],"prerequisites":{"required_diskspace":{"size_kb":"60000"},"supported_devices":[{"id":"572018-B21","target_guid":"","type":"other"},{"id":"539535-B21","target_guid":"","type":"other"},{"id":"466482-B21","target_guid":"","type":"other"},{"id":"638526-B21","target_guid":"","type":"other"},{"id":"691367-B21","target_guid":"","type":"other"},{"id":"751465-B21","target_guid":"","type":"other"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-04-03T10:39:13","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>The list of enhancements in 4.80&nbsp;version can be found in the HPE Virtual Connect Release Notes at URL<strong>:&nbsp;</strong><a href=\"http://www.hpe.com/info/vc/manuals\">http://www.hpe.com/info/vc/manuals</a></p>\n","latest_fixes_x_late":"<p>The list of issues resolved in 4.80&nbsp;version can be found in the HPE Virtual Connect Release Notes at&nbsp;URL<strong>:&nbsp;</strong><a href=\"http://www.hpe.com/info/vc/manuals\">http://www.hpe.com/info/vc/manuals</a></p>\n"},{"curr_enhancements_x_late":"<p>The list of enhancements in 4.85&nbsp;version can be found in the HPE Virtual Connect Release Notes at URL<strong>:&nbsp;</strong><a href=\"http://www.hpe.com/info/vc/manuals\">http://www.hpe.com/info/vc/manuals</a></p>\n","curr_fixes_x_late":"<p>The list of issues resolved in 4.85&nbsp;version can be found in the HPE Virtual Connect Release Notes at&nbsp;URL<strong>:&nbsp;</strong><a href=\"http://www.hpe.com/info/vc/manuals\">http://www.hpe.com/info/vc/manuals</a></p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"BL860ci2","value":"HP Integrity BL860c i2 Server Blade"},{"key":"I25","value":"HP ProLiant BL680c G7 Server"},{"key":"A19","value":"HP ProLiant BL465c G7 Server"},{"key":"I27","value":"HP ProLiant BL460c G7 Server"},{"key":"I28","value":"HP ProLiant BL490c G7 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"I25","value":"HP ProLiant BL620c G7 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"BL860ci4","value":"HP Integrity BL860c i4 Server Blade"},{"key":"BL870ci4","value":"HP Integrity BL870c i4 Server Blade"},{"key":"BL890ci4","value":"HP Integrity BL890c i4 Server Blade"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"BL870ci2","value":"HP Integrity BL870c i2 Server Blade"},{"key":"BL890ci2","value":"HP Integrity BL890c i2 Server Blade"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A20","value":"HP ProLiant BL685c G7 Server"},{"key":"I29","value":"HP ProLiant BL2x220c G7 Server"}],"sw_keys":[{"name":"vc8gb","sw_key_expectedpath":"firmware:vc8gb"},{"name":"vceth","sw_key_expectedpath":"firmware:vceth"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWRTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-30475752544e","Version":"HPG2"},{"DeviceName":"MB012000GWRTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-30475752544c","Version":"HPG2"},{"DeviceName":"MB010000GWRTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-30475752544b","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB014000GWRTN, MB012000GWRTL and MB010000GWRTK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp;</strong> None</p>\n"}],"files":[{"bytes":"18255377","datemodified":"2021-08-26T14:25:40","file_list":["/CP048337_BUILD_3.data","/CP048337.vmexe","/CP048337.vmexe64","/CP048337.vmfile","/CP048337_VMw.zip","/CP048337.xml","/payload.json","/CP048337_VMw.zip/index.xml","/CP048337_VMw.zip/vendor-index.xml","/CP048337_VMw.zip/metadata.zip","/CP048337_VMw.zip/vib20/CP048337/HPE_bootbank_CP048337_HPG2.3-7.0.0.15843807.vib","/CP048337_VMw.zip/metadata.zip/vendor-index.xml","/CP048337_VMw.zip/metadata.zip/vmware.xml","/CP048337_VMw.zip/metadata.zip/vibs/CP048337--184982332656156337.xml","/CP048337_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048337_HPG2.3-7.0.0.15843807.xml"],"md5sum":"9296018b20b707d5604420e990d3754d","name":"CP048337.zip","release":"2021-08-26T14:20:18","revision":"0","sha1sum":"d93ec5bfdecc21776eb5d42e3b395d3d40214bf4","size":"17MB","target_guids":["4d2340a5-3042-3431-3030-30475752544e","4d2340a5-3042-3231-3030-30475752544c","4d2340a5-3042-3031-3030-30475752544b"],"type_of_change":"1","version":"HPG2","vib_list":[{"name":"CP048337","version":"HPG2.3-7.0.0.15843807"}]}],"id":{"product":"3fa689b1e0c54064af40f5128fac0e5b","version":"00ae617d61484de4bc52202efa2001a4"},"installation":{"command":"CP041453.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor ESXi - MB014000GWRTN、MB012000GWRTLおよびMB010000GWRTKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB014000GWRTN","target_guid":"4d2340a5-3042-3431-3030-30475752544e","type":"sata"},{"id":"MB012000GWRTL","target_guid":"4d2340a5-3042-3231-3030-30475752544c","type":"sata"},{"id":"MB010000GWRTK","target_guid":"4d2340a5-3042-3031-3030-30475752544b","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-05T21:22:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB010000GWRTK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB014000GWRTN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB012000GWRTL","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000400JWFWN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a5746574e","Version":"HPD5"},{"DeviceName":"MO000800JWFWP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57465750","Version":"HPD5"},{"DeviceName":"MO001600JWFWQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57465751","Version":"HPD5"},{"DeviceName":"MO003200JWFWR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57465752","Version":"HPD5"},{"DeviceName":"MO000960JWFWT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3936-304a57465754","Version":"HPD5"},{"DeviceName":"MO001920JWFWU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a57465755","Version":"HPD5"},{"DeviceName":"MO003840JWFWV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3834-304a57465756","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MO000400JWFWN, MO000800JWFWP, MO001600JWFWQ, MO003200JWFWR, MO000960JWFWT, MO001920JWFWU and MO003840JWFWV"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MO000400JWFWN、MO000800JWFWP、MO001600JWFWQ、MO003200JWFWR、MO000960JWFWT、MO001920JWFWUおよびMO003840JWFWV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MO000400JWFWN, MO000800JWFWP, MO001600JWFWQ, MO003200JWFWR, MO000960JWFWT, MO001920JWFWU and MO003840JWFWV&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"2943304","datemodified":"2021-07-25T17:38:20","file_list":["cp048627.xml","cpqsetup.exe","payload.json","setup.dll","TAPM4VVEHPD5.rel"],"md5sum":"880c18deb383ebeb0a8778ae693f0463","name":"cp048627.exe","release":"2021-07-25T17:31:04","revision":"0","sha1sum":"271a59501ded6579161d5961b7026d518178fc6f","size":"2MB","target_guids":["4d2340a5-304f-3030-3430-304a5746574e","4d2340a5-304f-3030-3830-304a57465750","4d2340a5-304f-3130-3630-304a57465751","4d2340a5-304f-3330-3230-304a57465752","4d2340a5-304f-3030-3936-304a57465754","4d2340a5-304f-3130-3932-304a57465755","4d2340a5-304f-3330-3834-304a57465756"],"type_of_change":"1","version":"HPD5"}],"id":{"product":"0d44f7068b8b4ccebd15e4e19fe5c5fa","version":"2f9b09e09468492891f4c391e61185e0"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MO000400JWFWN, MO000800JWFWP, MO001600JWFWQ, MO003200JWFWR, MO000960JWFWT, MO001920JWFWU and MO003840JWFWV Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows(x64)-  MO000400JWFWN、MO000800JWFWP、MO001600JWFWQ、MO003200JWFWR、MO000960JWFWT、MO001920JWFWU、およびMO003840JWFWVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MO003200JWFWR","target_guid":"4d2340a5-304f-3330-3230-304a57465752","type":"sas"},{"id":"MO001920JWFWU","target_guid":"4d2340a5-304f-3130-3932-304a57465755","type":"sas"},{"id":"MO001600JWFWQ","target_guid":"4d2340a5-304f-3130-3630-304a57465751","type":"sas"},{"id":"MO000960JWFWT","target_guid":"4d2340a5-304f-3030-3936-304a57465754","type":"sas"},{"id":"MO000800JWFWP","target_guid":"4d2340a5-304f-3030-3830-304a57465750","type":"sas"},{"id":"MO000400JWFWN","target_guid":"4d2340a5-304f-3030-3430-304a5746574e","type":"sas"},{"id":"MO003840JWFWV","target_guid":"4d2340a5-304f-3330-3834-304a57465756","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T13:40:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MO003840JWFWV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200JWFWR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000400JWFWN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001920JWFWU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600JWFWQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000960JWFWT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800JWFWP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains drivers for the HPE QLogic FastLinQ 10/25/50 GbE Multifunction Adapters running under VMware vSphere 6.5."},{"lang":"ja","x_late":"この製品は、VMware vSphere 6.5上で動作するHPE QLogic FastLinQ 10/25/50 GbEマルチファンクションアダプターのためのドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains the following drivers:</p>\n\n<ul>\n\t<li>qedentv, version&nbsp;3.11.16.0</li>\n\t<li>qedrntv, version&nbsp;3.11.16.0</li>\n\t<li>qedf, version&nbsp;1.3.42.50</li>\n\t<li>scsi-qedil, version 1.15.15.0</li>\n</ul>\n"}],"files":[{"bytes":"4297259","datemodified":"2021-01-18T03:32:50","file_list":["/cp046222.xml","/qedentv-bundle-esx65-3.0.201.7_signed.zip","/qedentv-bundle-esx65-3.0.201.7_signed.zip/index.xml","/qedentv-bundle-esx65-3.0.201.7_signed.zip/vendor-index.xml","/qedentv-bundle-esx65-3.0.201.7_signed.zip/metadata.zip","/qedentv-bundle-esx65-3.0.201.7_signed.zip/vib20/qedrntv/QLC_bootbank_qedrntv_3.11.16.0-1OEM.650.0.0.4598673.vib","/qedentv-bundle-esx65-3.0.201.7_signed.zip/vib20/qedf/QLC_bootbank_qedf_1.3.42.50-1OEM.600.0.0.2768847.vib","/qedentv-bundle-esx65-3.0.201.7_signed.zip/vib20/scsi-qedil/QLC_bootbank_scsi-qedil_1.15.15.0-1OEM.600.0.0.2494585.vib","/qedentv-bundle-esx65-3.0.201.7_signed.zip/vib20/qedentv/QLC_bootbank_qedentv_3.11.16.0-1OEM.650.0.0.4598673.vib","/qedentv-bundle-esx65-3.0.201.7_signed.zip/metadata.zip/vendor-index.xml","/qedentv-bundle-esx65-3.0.201.7_signed.zip/metadata.zip/vmware.xml","/qedentv-bundle-esx65-3.0.201.7_signed.zip/metadata.zip/bulletins/qedentv-bundle-3.0.201.7_signed.xml","/qedentv-bundle-esx65-3.0.201.7_signed.zip/metadata.zip/vibs/qedrntv--5432460915364582024.xml","/qedentv-bundle-esx65-3.0.201.7_signed.zip/metadata.zip/vibs/qedf-403674252693421673.xml","/qedentv-bundle-esx65-3.0.201.7_signed.zip/metadata.zip/vibs/qedentv--7190238033104912737.xml","/qedentv-bundle-esx65-3.0.201.7_signed.zip/metadata.zip/vibs/scsi-qedil--2754727834483470936.xml"],"md5sum":"3baffdf1a90192768387b0996e077de6","name":"cp046222.zip","release":"2021-01-18T03:31:30","revision":"0","sha1sum":"3386889242cc37f94d2a6c517ab3de348470ccff","size":"4MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec660dedd2","20a6e8e4-bf33-4c71-a6bf-d9ecd558d67b","20a6e8e4-bf33-4c71-a6bf-d9ec6a25bd0a","20a6e8e4-bf33-4c71-a6bf-d9ec89e84beb"],"type_of_change":"0","version":"2021.04.05","vib_list":[{"name":"qedrntv","version":"3.11.16.0-1OEM.650.0.0.4598673"},{"name":"qedf","version":"1.3.42.50-1OEM.600.0.0.2768847"},{"name":"scsi-qedil","version":"1.15.15.0-1OEM.600.0.0.2494585"},{"name":"qedentv","version":"3.11.16.0-1OEM.650.0.0.4598673"}]}],"id":{"product":"cc4bfdeb5e654d1bb1a491db23bb09b4","version":"cc1e1edd585648c0adab7dce36affd66"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic FastLinQ 10/25/50 GbE Multifunction Driver for VMware vSphere 6.5"},{"lang":"ja","x_late":"HPE QLogic FastLinQ 10/25/50 GbEマルチファンクションドライバーfor VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"8070","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021d","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021f","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-807015900220","type":"pci","ven":"1077"},{"dev":"8070","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8070159002bd","type":"pci","ven":"1077"},{"dev":"8090","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8090159002bd","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-809015900220","type":"pci","ven":"1077"},{"dev":"8090","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80901590021d","type":"pci","ven":"1077"},{"dev":"8090","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80901590021f","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021a","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021b","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue where Fibre Channel over Ethernet (FCoE) frame with CRC size and End Of Frame(EOF) size.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product corrects an issue runs out of MSI-X interrupt vectors caused what Purple Screen of Death (PSOD)</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"scsi-qedil:1.15.15.0-1OEM.600.0.0.2494585","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qedrntv:3.11.16.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qedf:1.3.42.50-1OEM.600.0.0.2768847","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qedentv:3.11.16.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000JEQUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHC8SDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a45515556","Version":"HPDB"},{"DeviceName":"MB8000JEQVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHC8SDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3842-3030-304a45515641","Version":"HPDB"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB6000JEQUV and MB8000JEQVA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB6000JEQUV and MB8000JEQVA Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDB<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD9<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None.</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp;</strong> None</p>\n"}],"files":[{"bytes":"3647216","datemodified":"2021-07-25T15:39:33","file_list":["cp048614.xml","cpqsetup.exe","HAHC8SDB.rel","payload.json","setup.dll"],"md5sum":"413ed7a08d8c83fb05cb40ec1c1f1c8c","name":"cp048614.exe","release":"2021-07-25T15:32:07","revision":"0","sha1sum":"5db5fdc5c4c5ba0b145a7a7f25ea309b4351f706","size":"3MB","target_guids":["002340a5-4d00-3642-3030-304a45515556","002340a5-4d00-3842-3030-304a45515641"],"type_of_change":"1","version":"HPDB"}],"id":{"product":"f8be51b7e24840dda7b3bf9d2b21fe22","version":"154e6fa21beb4c0782b8c6cb16b9c8dd"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB6000JEQUV and MB8000JEQVA Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB6000JEQUV およびMB8000JEQVAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB6000JEQUV","target_guid":"002340a5-4d00-3642-3030-304a45515556","type":"sas"},{"id":"MB8000JEQVA","target_guid":"002340a5-4d00-3842-3030-304a45515641","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T11:58:26","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB8000JEQVA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB6000JEQUV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JXLBA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WpariscASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a584c4241","Version":"HPD2"},{"DeviceName":"MB018000JXLAU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WpariscASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a584c4155","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB016000JXLBA and MB018000JXLAU"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB016000JXLBA and MB018000JXLAU Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>VENDOR IDENTIFICATION field changed from &ldquo;HP&rdquo; to &ldquo;HPE&rdquo; and Reliability improvements.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5088136","datemodified":"2021-08-11T18:51:25","file_list":["cp049254.xml","cpqsetup.exe","payload.json","setup.dll","WpariscASFD2.rel"],"md5sum":"58e2f8260ad5d1bd73d9b675123ccd63","name":"cp049254.exe","release":"2021-08-11T18:42:06","revision":"0","sha1sum":"69b8ed3f237714e4f1cd2960ea97843190953119","size":"4MB","target_guids":["4d2340a5-3042-3631-3030-304a584c4241","4d2340a5-3042-3831-3030-304a584c4155"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"d1880357890d41959529b109e2a869e4","version":"6c2bb0a2cb824640aedba2dca2fe0945"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB016000JXLBA and MB018000JXLAU Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB016000JXLBA","target_guid":"4d2340a5-3042-3631-3030-304a584c4241","type":"sas"},{"id":"MB018000JXLAU","target_guid":"4d2340a5-3042-3831-3030-304a584c4155","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-11T14:23:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>VENDOR IDENTIFICATION field changed from &ldquo;HP&rdquo; to &ldquo;HPE&rdquo; and Reliability improvements.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB018000JXLAU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB016000JXLBA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO001600KWVNB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b57564e42","Version":"HPK3"},{"DeviceName":"MO003200KWVNC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b57564e43","Version":"HPK3"},{"DeviceName":"MO006400KWVND","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b57564e44","Version":"HPK3"},{"DeviceName":"MT001600KWSTB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3130-3630-304b57535442","Version":"HPK3"},{"DeviceName":"MT003200KWSTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3330-3230-304b57535443","Version":"HPK3"},{"DeviceName":"MT006400KWSTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3630-3430-304b57535444","Version":"HPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MO001600KWVNB, MO003200KWVNC, MO006400KWVND, MT001600KWSTB, MT003200KWSTC and MT006400KWSTD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online NVMe SSD Flash Component for Linux (x64) - &nbsp;MO001600KWVNB, MO003200KWVNC, MO006400KWVND, MT001600KWSTB, MT003200KWSTC and MT006400KWSTD Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p>&nbsp;<strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"7226425","datemodified":"2021-07-25T12:28:45","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-cea219e4b1-HPK3-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-cea219e4b1-HPK3-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-cea219e4b1-HPK3-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-cea219e4b1-HPK3-3.1/CP048240.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-cea219e4b1-HPK3-3.1/GP1725b0HPK3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-cea219e4b1-HPK3-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-cea219e4b1-HPK3-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-cea219e4b1-HPK3-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-cea219e4b1-HPK3-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048240.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048240.scexe"],"md5sum":"d29d79e2ba819321d76350864c1b7641","name":"firmware-hdd-cea219e4b1-HPK3-3.1.x86_64.rpm","release":"2021-07-25T12:16:05","revision":"0","sha1sum":"14542b73a0e999bbca93d7a90145ccd2e8092afb","size":"6MB","target_guids":["4d2340a5-304f-3130-3630-304b57564e42","4d2340a5-304f-3330-3230-304b57564e43","4d2340a5-304f-3630-3430-304b57564e44","4d2340a5-3054-3130-3630-304b57535442","4d2340a5-3054-3330-3230-304b57535443","4d2340a5-3054-3630-3430-304b57535444"],"type_of_change":"1","version":"HPK3"}],"id":{"product":"9548ad0612e149baa76eccbb5ce95cee","version":"4efb861776bf4c21afa5ed0fdfb7ce11"},"installation":{"command":"CP041698.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left: 30pt;\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（.rpm拡張子の付いていないrpmファイル名）を実行します。</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p>\n\n<ul>\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>追加情報：</strong></p>\n\n<p style=\"margin-left: 30pt;\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を解凍するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するには Service Pack for ProLiant から以下の手順に従ってください:</strong><br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - MO001600KWVNB, MO003200KWVNC, MO006400KWVND, MT001600KWSTB, MT003200KWSTC and MT006400KWSTD Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - MO001600KWVNB、MO003200KWVNC、MO006400KWVND、MT001600KWSTB、MT003200KWSTC、およびMT006400KWSTDドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MO006400KWVND","target_guid":"4d2340a5-304f-3630-3430-304b57564e44","type":"nvme"},{"id":"MO003200KWVNC","target_guid":"4d2340a5-304f-3330-3230-304b57564e43","type":"nvme"},{"id":"MO001600KWVNB","target_guid":"4d2340a5-304f-3130-3630-304b57564e42","type":"nvme"},{"id":"MT001600KWSTB","target_guid":"4d2340a5-3054-3130-3630-304b57535442","type":"nvme"},{"id":"MT003200KWSTC","target_guid":"4d2340a5-3054-3330-3230-304b57535443","type":"nvme"},{"id":"MT006400KWSTD","target_guid":"4d2340a5-3054-3630-3430-304b57535444","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-01T09:16:16","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Fixed SSD weargauge report error issue.</li>\n\t<li>Fixed Assign FWState as TR_DONE_ERR at the correct location.</li>\n\t<li>Prepare proper response data for Get Message Type Supported MCTP Command.</li>\n\t<li>Added code to preserve current feature values cross live firmware update.</li>\n\t<li>Allocate 4 bytes instead of 2 bytes for parameter code.</li>\n\t<li>Changed the value for NLB equal to NSize -1.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MT006400KWSTD","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO001600KWVNB","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT003200KWSTC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO003200KWVNC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO006400KWVND","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT001600KWSTB","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZPLJ1T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK75H3Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3154-3648f52fd02c","Version":"EPK75H3Q"},{"DeviceName":"MZPLJ3T2HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK75H3Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3354-3248fdc50136","Version":"EPK75H3Q"},{"DeviceName":"MZPLJ6T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK75H3Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3654-3448bda98199","Version":"EPK75H3Q"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MZPLJ1T6HBJR-000H3, MZPLJ3T2HBJR-000H3 and MZPLJ6T4HALA-000H3"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Linux (x64) - MZPLJ1T6HBJR-000H3, MZPLJ3T2HBJR-000H3 and MZPLJ6T4HALA-000H3&nbsp; Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>EPK75H3Q</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; EPK74H3Q</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; EPK74H3Q</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Fixed False UECC issue at idle power mode.</li>\n\t<li>Old FW download Blocking (EPK70H3Q~EPK74H3Q).</li>\n\t<li>FW is changed off the option of TX data alignment for each lane.</li>\n\t<li>FW is changed to clear the interrupt after TLP Complete when PCIe config read operation.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL: <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us\" style=\"color: rgb(5, 99, 193); text-decoration: underline;\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"9402131","datemodified":"2021-07-25T12:32:56","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-6628fce235-EPK75H3Q-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-6628fce235-EPK75H3Q-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-6628fce235-EPK75H3Q-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6628fce235-EPK75H3Q-2.1/CP048228.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-6628fce235-EPK75H3Q-2.1/EPK75H3Q.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-6628fce235-EPK75H3Q-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6628fce235-EPK75H3Q-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-6628fce235-EPK75H3Q-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-6628fce235-EPK75H3Q-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048228.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048228.scexe"],"md5sum":"0f2ac6883fe15dfece90ef359fbb554b","name":"firmware-hdd-6628fce235-EPK75H3Q-2.1.x86_64.rpm","release":"2021-07-25T12:20:14","revision":"0","sha1sum":"21f43b17f8cdefb881ea625cdd7ff8bf15367221","size":"8MB","target_guids":["4d2340a5-505a-4a4c-3154-3648f52fd02c","4d2340a5-505a-4a4c-3354-3248fdc50136","4d2340a5-505a-4a4c-3654-3448bda98199"],"type_of_change":"2","version":"EPK75H3Q"}],"id":{"product":"77f2ff3d7ebf4999a5ec47887c09ecdf","version":"d5bbe0ba984446c08d530bb696d92764"},"installation":{"command":"CP043037.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p><strong>Additional Information:</strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p><strong>追加情報:</strong></p>\n\n<p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - MZPLJ1T6HBJR-000H3, MZPLJ3T2HBJR-000H3 and MZPLJ6T4HALA-000H3 Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - MZPLJ1T6HBJR-000H3、MZPLJ3T2HBJR-000H3、およびMZPLJ6T4HALA-000H3ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MZPLJ6T4HALA-000H3","target_guid":"4d2340a5-505a-4a4c-3654-3448bda98199","type":"nvme"},{"id":"MZPLJ3T2HBJR-000H3","target_guid":"4d2340a5-505a-4a4c-3354-3248fdc50136","type":"nvme"},{"id":"MZPLJ1T6HBJR-000H3","target_guid":"4d2340a5-505a-4a4c-3154-3648f52fd02c","type":"nvme"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-01T04:38:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Fixed False UECC issue at idle power mode.</li>\n\t<li>Old FW download Blocking (EPK70H3Q~EPK74H3Q).</li>\n\t<li>FW is changed off the option of TX data alignment for each lane.</li>\n\t<li>FW is changed to clear the interrupt after TLP Complete when PCIe config read operation.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL: <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us</a></li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Fixed False UECC issue at idle power mode.</li>\n\t<li>Old FW download Blocking (EPK70H3Q~EPK74H3Q).</li>\n\t<li>FW is changed off the option of TX data alignment for each lane.</li>\n\t<li>FW is changed to clear the interrupt after TLP Complete when PCIe config read operation.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL: <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MZPLJ6T4HALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZPLJ1T6HBJR-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZPLJ3T2HBJR-000H3","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000400JWUFT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57554654","Version":"HPD3"},{"DeviceName":"MO000800JWUFU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57554655","Version":"HPD3"},{"DeviceName":"MO001600JWUFV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57554656","Version":"HPD3"},{"DeviceName":"MO003200JWUGA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57554741","Version":"HPD3"},{"DeviceName":"MO006400JWUGB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a57554742","Version":"HPD3"},{"DeviceName":"EO000400JWUGC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57554743","Version":"HPD3"},{"DeviceName":"EO000800JWUGD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57554744","Version":"HPD3"},{"DeviceName":"EO001600JWUGE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57554745","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MO000400JWUFT、MO000800JWUFU、MO001600JWUFV、MO003200JWUGA、MO006400JWUGB、EO000400JWUGC、EO000800JWUGD、およびEO001600JWUGE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD1<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong>&nbsp; &nbsp; &nbsp;&nbsp;</p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5247680","datemodified":"2021-07-23T09:47:28","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD3-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD3-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD3-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD3-3.1/CP048212.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD3-3.1/hbcpssssefd3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD3-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD3-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD3-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD3-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048212.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048212.scexe"],"md5sum":"54f749118ad77b31db9fba3da575c1e9","name":"firmware-hdd-ef93133161-HPD3-3.1.x86_64.rpm","release":"2021-07-23T09:34:11","revision":"0","sha1sum":"6e4b21b39b7c2d133edcc47d8af62a5632982408","size":"5MB","target_guids":["4d2340a5-304f-3030-3430-304a57554654","4d2340a5-304f-3030-3830-304a57554655","4d2340a5-304f-3130-3630-304a57554656","4d2340a5-304f-3330-3230-304a57554741","4d2340a5-304f-3630-3430-304a57554742","452340a5-304f-3030-3430-304a57554743","452340a5-304f-3030-3830-304a57554744","452340a5-304f-3130-3630-304a57554745"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"07a5f3ddb9bd4168818fb38406e49473","version":"4cc4081d6c2a4ecd91cd55c8a8d84d1f"},"installation":{"command":"CP040353.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64)  - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MO000400JWUFT、MO000800JWUFU、MO001600JWUFV、MO003200JWUGA、MO006400JWUGB、EO000400JWUGC、EO000800JWUGD、およびEO001600JWUGEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MO006400JWUGB","target_guid":"4d2340a5-304f-3630-3430-304a57554742","type":"sas"},{"id":"MO003200JWUGA","target_guid":"4d2340a5-304f-3330-3230-304a57554741","type":"sas"},{"id":"MO001600JWUFV","target_guid":"4d2340a5-304f-3130-3630-304a57554656","type":"sas"},{"id":"EO001600JWUGE","target_guid":"452340a5-304f-3130-3630-304a57554745","type":"sas"},{"id":"MO000800JWUFU","target_guid":"4d2340a5-304f-3030-3830-304a57554655","type":"sas"},{"id":"EO000800JWUGD","target_guid":"452340a5-304f-3030-3830-304a57554744","type":"sas"},{"id":"MO000400JWUFT","target_guid":"4d2340a5-304f-3030-3430-304a57554654","type":"sas"},{"id":"EO000400JWUGC","target_guid":"452340a5-304f-3030-3430-304a57554743","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T12:13:27","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EO000800JWUGD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200JWUGA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO001600JWUGE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000400JWUGC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600JWUFV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000400JWUFT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800JWUFU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO006400JWUGB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following storage controllers: Smart Array P230i, P430, P431, P731m, P830i, and P830"},{"lang":"cn","x_late":"该x64智能组件为以下存储控制器提供固件： 智能阵列 P230i、P430、P431、 P731m、P830i 和 P830"},{"lang":"tw","x_late":"此 x64 智慧型元件提供適用於下列儲存控制器的韌體： Smart Array P230i、P430、P431、P731m、P830i 及 P830"},{"lang":"ko","x_late":"이 x64 스마트 구성 요소는 다음과 같은 스토리지 컨트롤러용 펌웨어를 제공합니다. 스마트 어레이 P230i, P430, P431, P731m, P830i, P830"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のストレージコントローラー：SmartアレイP230i, P430, P431, P731m, P830i, およびP830のファームウェアを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Supplemental Update / Online ROM Flash Component for Linux (x64) - Smart Array P230i,&nbsp;P430, P431, P731m, P830i, and P830</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;5.02<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;4.54(B)<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;4.10<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Problems Fixed:</strong>&nbsp; &nbsp; &nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"6205987","datemodified":"2019-08-08T19:27:29","file_list":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-112204add8-5.02-1.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-112204add8-5.02-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-112204add8-5.02-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-112204add8-5.02-1.1/CP039413.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-112204add8-5.02-1.1/firmware_signed.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-112204add8-5.02-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-112204add8-5.02-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-112204add8-5.02-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP039413.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP039413.scexe"],"md5sum":"56683b9fa47d99deadc41120db13cee2","name":"firmware-smartarray-112204add8-5.02-1.1.x86_64.rpm","release":"2019-08-08T19:17:03","revision":"0","sha1sum":"a7f738ad396836db2c8e27d2efc86a0993472f3b","size":"5MB","target_guids":[],"type_of_change":"1","version":"5.02"}],"id":{"product":"453b4ea1f87f45c98bbb1d1a44fa8e02","version":"330456640bee4a069f7317cab0d05064"},"installation":{"command":"CP039413.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActiveIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Smart Array HPCISSS3 Controller Driver version 100.18.2.64 must not be used for firmware update.  Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfd368f11","ServerModel":["*"],"Target_guids":[],"Type":"NE","Version":"100.18.2.64","description":"HPE ProLiant Smart Array HPCISSS3 Controller Driver version 100.18.2.64 must not be used for firmware update.  Update the driver and reboot before attempting firmware update."}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong><em>Updating firmware with rpm installed:</em></strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li>\n\t<li>The CP039413.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;hp-firmware-smartarray-112204add8-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:&nbsp;</li>\n</ul>\n\n<p style=\"margin-left:40px\"># ./ CP039413.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)</p>\n\n<p style=\"margin-left:40px\">#&nbsp;<em>./hpsetup</em> in the &#39;/usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-112204add8-*&#39; location</p>\n\n<ul>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><strong><em>Updating firmware without installing the rpm:</em></strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-112204add8-*&#39; location and run <em>./hpsetup</em> to update the firmware. The actual name of the &#39;hp-firmware-smartarray-112204add8-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps</p>\n\n<p><strong>To use HP Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\">HPE </a><u><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a> </u>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\"><u>HPE USB Key Creator Utility</u></a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /hp/swpackages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow HP Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /hp/swpackages</li>\n\t<li>Locate Start.html which is found in the root of the ISO</li>\n\t<li>Open the html file in a supported browser</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Supplemental Update / Online ROM Flash Component for Linux (x64) - Smart Array P230i, P430, P431, P731m, P830i, and P830"},{"lang":"cn","x_late":"Linux (x64)版补充更新/在线ROM刷新组件 - 智能阵列P230i、P430、P431、P731m、P830i和P830"},{"lang":"tw","x_late":"適用於 Linux (x64) 的補充更新/線上 ROM 更新元件 - Smart Array P230i、P430、P431、P731m、P830i 與 P830"},{"lang":"ko","x_late":"Linux(x64)용 추가 업데이트/온라인 ROM 업데이트 구성 요소 - 스마트 어레이 P230i, P430, P431, P731m 및 P830i 및 P830"},{"lang":"ja","x_late":"サプリメンタルアップデート/オンラインROMフラッシュコンポーネント for Linux (x64) - SmartアレイP230i、P430、P431、P731m、P830i および P830"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"323c","subdev":"1922","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1923","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1921","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1924","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1926","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1928","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-05-09T06:13:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>DDR cache could be randomly disabled after several boots</li>\n\t<li>A hot-inserted replacement drive might show as a predictive failure if the original drive was identified as a predictive failure.</li>\n\t<li>Controller cache module might be marked as permanently disabled if the Smart Storage Battery is removed or failed while the system is online, even if SSA was previously used to enable write caching without a backup power source.</li>\n\t<li>Controller can become unresponsive due to a SmartCache pending flush operation when a read-ahead and a read-fill are performed in sequent.</li>\n\t<li>System might stop responding if a parity error is found during surface scan of a RAID6 volume. (POST Lockup 0x13)</li>\n\t<li>System fans might go to 100% if connected drives were spun down</li>\n\t<li>Issue where a controller crash dump may not be collected after a controller failure</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>The firmware updates could fail while SmartCache is enabled due to active I/O in the Smart Cache.</li>\n\t<li>The serial output of the expander could fail to be populated in the controller logs due to the buffer not being handled appropriately by the controller</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"J06","value":"HP ProLiant MicroServer Gen8"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"P78","value":"HP ProLiant ML310e Gen8 v2 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"}],"sw_keys":[{"name":"1928103C","sw_key_expectedpath":"firmware"},{"name":"1923103C","sw_key_expectedpath":"firmware"},{"name":"1922103C","sw_key_expectedpath":"firmware"},{"name":"1924103C","sw_key_expectedpath":"firmware"},{"name":"1921103C","sw_key_expectedpath":"firmware"},{"name":"1926103C","sw_key_expectedpath":"firmware"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]}],"documentation":[],"files":[{"bytes":"6085534","datemodified":"2019-08-07T10:53:16","file_list":["/CP040773.vmexe","/CP040773.vmfile","/CP040773.xml","/README.txt"],"md5sum":"a0759abeee60c9b0b52b3cf0437c736c","name":"CP040773.zip","release":"2019-08-07T15:53:06","revision":"0","sha1sum":"4df7aec7225c5ba70ff64fd31a00ca6d6d4fca7d","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.66_07-19-2019","vib_list":[]}],"id":{"product":"e75e513801aa44c1b7614f2e99083381","version":"8484bf0f92144d509ced7c7e3e8405f4"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component requires that the CRU driver be loaded before the component can run.</p>\n\n<p>The minimum CRU version for 5.5 is 5.5.4.1.<br />\nThe minimum CRU version for 6.0 is 6.0.8.<br />\nThe minimum CRU version for 6.5 is 6.5.8.<br />\nThe minimum CRU version for 6.7 is 6.7.10.<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>SPP Offline mode boots a special Linux OS environment, thus the Linux Components are used, not the VMware Components</li>\n</ul>\n\n<p><br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Download the appropriate SPP</li>\n\t<li>Add the component to the SPP</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run&nbsp; SUM</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps to complete the firmware update</li>\n\t<li>Refer to the SPP documentation for detailed instructions at:&nbsp; <a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Component ( CPxxxxxx.zip) in a temporary directory</li>\n\t<li>From the same directory, unzip the Component:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>To perform the standalone installation, execute the command:<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>Follow the directions given by the Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system for the firmware update to take effect</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>重要: このコンポーネントは、実行する前にCRUドライバーがロードされている必要があります。</p>\n\n<p>5.5の最小CRUバージョンは5.5.4.1です。<br />\n6.0の最小CRUバージョンは6.0.8です。<br />\n6.5の最小CRUバージョンは6.5.8です。<br />\n6.7の最小CRUバージョンは6.7.10です。<br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMwareコンポーネントではなく、Linuxコンポーネントが用いられます</li>\n</ul>\n\n<p><br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします</li>\n\t<li>SPPにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします</li>\n\t<li>SUMを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します</li>\n\t<li>SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います</li>\n\t<li>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>コンポーネント (CPxxxxxx.zip)を一時ディレクトリに置きます</li>\n\t<li>同じディレクトリからコンポーネントをunzipします:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>スタンドアロンのインストールを行うために、次のコマンドを実行します：<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>コンポーネントの指示に従います</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n\t<li>システムを再起動し、ファームウェアのアップデートを有効にします</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware - HPE ProLiant EC200a (U26) Server/HPE ProLiant Thin Micro TM200 (U26) Server"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"5","minor":"5","name":"VMware vSphere 5.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-08-24T23:03:41","revision_history":[{"lang":"en","latest_enhancements_x_late":null,"latest_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>Updated the Intel processor microcode to the latest version.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"<p>None</p>\n","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigation for an Intel sighting where the system may experience a machine check after updating to the latest System ROM which contained a fix for an Intel TSX (Transactional Synchronizations Extensions) sightings. The previous microcode was first introduced in the v2.62 System ROM. This issue only impacts systems configured with Intel Xeon&reg; D-1500 processors. This issue is not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U26","value":"HPE ProLiant Easy Connect EC200a Managed Hybrid Server"}],"sw_keys":[{"name":"U26","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The HPE SNMP Agents (hp-snmp-agents) is a collection  of SNMP  protocol based agents  and tools which enables monitoring of fans, power supplies, temperature sensors and other management events via SNMP. It also provides the following: Foundation and Server agents, Storage Subsystem agents, Network Subsystem agents, the SNMP Dynamically Loaded Module, and the web support applications."},{"lang":"ja","x_late":"HPE SNMPエージェント(hp-snmp-agents)は、ファン、電源、温度センサー、およびその他SNMP経由の管理イベントの監視を可能にするSNMPプロトコルベースのエージェントとツールを集めたものです。同様に、以下を提供します。FoundationおよびServerエージェント、Storage Subsystemエージェント、Network Subsystemエージェント、SNMP動的ロードモジュール、およびWebサポートアプリケーション。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[],"files":[{"bytes":"1332809","datemodified":"2021-08-25T03:49:04","file_list":["./etc/hp-snmp-agents.conf","./etc/logrotate.d/hp-snmp-agents","./opt/hp/hp-snmp-agents","./opt/hp/hp-snmp-agents/addons","./opt/hp/hp-snmp-agents/cma.conf","./opt/hp/hp-snmp-agents/hp-snmp-agents.license","./opt/hp/hp-snmp-agents/hp-snmp-agents.manifest","./opt/hp/hp-snmp-agents/hp-snmp-agents.rebuild.spec","./opt/hp/hp-snmp-agents/hprpm.xpm","./opt/hp/hp-snmp-agents/mibs","./opt/hp/hp-snmp-agents/mibs/cmafdtnobjects.conf","./opt/hp/hp-snmp-agents/mibs/cmanicobjects.conf","./opt/hp/hp-snmp-agents/mibs/cmaobjects.conf","./opt/hp/hp-snmp-agents/mibs/cmaobjects.mibdef","./opt/hp/hp-snmp-agents/mibs/cmaobjects.mibver","./opt/hp/hp-snmp-agents/mibs/cmaobjects.regmib","./opt/hp/hp-snmp-agents/mibs/cmastorobjects.conf","./opt/hp/hp-snmp-agents/mibs/cmasvrobjects.conf","./opt/hp/hp-snmp-agents/nic","./opt/hp/hp-snmp-agents/nic/bin","./opt/hp/hp-snmp-agents/nic/bin/cmanicd","./opt/hp/hp-snmp-agents/nic/bin/hpetfe","./opt/hp/hp-snmp-agents/nic/etc","./opt/hp/hp-snmp-agents/nic/etc/HPcmanic.pp","./opt/hp/hp-snmp-agents/nic/etc/cmanic","./opt/hp/hp-snmp-agents/nic/etc/cmanicd","./opt/hp/hp-snmp-agents/rebuild","./opt/hp/hp-snmp-agents/server","./opt/hp/hp-snmp-agents/server/bin","./opt/hp/hp-snmp-agents/server/bin/cmahealthd","./opt/hp/hp-snmp-agents/server/bin/cmahostd","./opt/hp/hp-snmp-agents/server/bin/cmapeerd","./opt/hp/hp-snmp-agents/server/bin/cmaperfd","./opt/hp/hp-snmp-agents/server/bin/cmasm2d","./opt/hp/hp-snmp-agents/server/bin/cmastdeqd","./opt/hp/hp-snmp-agents/server/bin/cmathreshd","./opt/hp/hp-snmp-agents/server/bin/distro-id.sh","./opt/hp/hp-snmp-agents/server/etc","./opt/hp/hp-snmp-agents/server/etc/cmad","./opt/hp/hp-snmp-agents/server/etc/cmahealthd","./opt/hp/hp-snmp-agents/server/etc/cmahostd","./opt/hp/hp-snmp-agents/server/etc/cmapeerd","./opt/hp/hp-snmp-agents/server/etc/cmaperfd","./opt/hp/hp-snmp-agents/server/etc/cmarackd","./opt/hp/hp-snmp-agents/server/etc/cmasm2d","./opt/hp/hp-snmp-agents/server/etc/cmastdeqd","./opt/hp/hp-snmp-agents/server/etc/cmathreshd","./opt/hp/hp-snmp-agents/server/etc/cpqbssa.txt","./opt/hp/hp-snmp-agents/server/etc/cpqriisd","./opt/hp/hp-snmp-agents/share","./opt/hp/hp-snmp-agents/share/doc","./opt/hp/hp-snmp-agents/share/doc/HP_SNMP_Trap_Guide.txt","./opt/hp/hp-snmp-agents/storage","./opt/hp/hp-snmp-agents/storage/bin","./opt/hp/hp-snmp-agents/storage/bin/cmaeventd","./opt/hp/hp-snmp-agents/storage/bin/cmafcad","./opt/hp/hp-snmp-agents/storage/bin/cmaidad","./opt/hp/hp-snmp-agents/storage/bin/cmaided","./opt/hp/hp-snmp-agents/storage/bin/cmasasd","./opt/hp/hp-snmp-agents/storage/bin/cmascsid","./opt/hp/hp-snmp-agents/storage/bin/libcpqimgr-x86_64.so","./opt/hp/hp-snmp-agents/storage/etc","./opt/hp/hp-snmp-agents/storage/etc/cmaeventd","./opt/hp/hp-snmp-agents/storage/etc/cmafcad","./opt/hp/hp-snmp-agents/storage/etc/cmaidad","./opt/hp/hp-snmp-agents/storage/etc/cmaided","./opt/hp/hp-snmp-agents/storage/etc/cmasasd","./opt/hp/hp-snmp-agents/storage/etc/cmascsid","./opt/hp/hp-snmp-agents/storage/etc/cmastorobjects.conf","./opt/hp/hp-snmp-agents/utils","./opt/hp/hp-snmp-agents/utils/usb-device.sh","./opt/hp/hp-snmp-agents/webagent","./opt/hp/hp-snmp-agents/webagent/csginkgo","./sbin/hpsnmpconfig","./usr/lib/systemd/scripts/hp-snmp-agents.sh","./usr/lib/systemd/system/hp-snmp-agents.service","./usr/lib64/libcmaX64.so","./usr/lib64/libcmaX64.so.1","./usr/lib64/libcmaX64.so.1.0","./usr/lib64/libcmacommon64.so","./usr/lib64/libcmacommon64.so.1","./usr/lib64/libcmacommon64.so.1.0","./usr/lib64/libcmaconf64.so","./usr/lib64/libcmaconf64.so.1","./usr/lib64/libcmaconf64.so.1.0","./usr/lib64/libcmapeer64.so","./usr/lib64/libcmapeer64.so.1","./usr/lib64/libcmapeer64.so.1.0","./usr/share/man/man4/hp-snmp-agents.4.gz","./usr/share/man/man8/cmanicd.8.gz","./usr/share/smartupdate/hp-snmp-agents/component.xml","./var/log/hp-snmp-agents","./var/spool/compaq"],"md5sum":"96a09b3a7cb7d5ef7112a9e9b65676f3","name":"hp-snmp-agents-10.94-689.8.sles15.x86_64.rpm","release":"2021-08-25T03:40:11","revision":"0","sha1sum":"e3bdf3a6afc363fa5bdf75d57e5169738aea6b31","size":"1MB","target_guids":[],"type_of_change":"0","version":"10.9.4"}],"id":{"product":"f967d142bb1c4216acd867e7f8bae50f","version":"77371b9b3c54407099e2759aa31b522d"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<P>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</P>\n<P>To install the package, type: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<B><I>rpm -ivh hp-snmp-agents-&lt;version&gt;.rpm</I></B></P>\n<P>To check whether the package is loaded properly type: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<B><I>/etc/init.d/hp-snmp-agents status</I></B></P>\n<P>Additional help is available by typing: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<B><I>man hp-snmp-agents</I></B></P>"},{"lang":"ja","x_late":"<P>システム管理者（root）としてログインし、RPMをご使用のハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</P>\n<P>パッケージをインストールするには、次のようにタイプします。</P>\n<P>         <B><I>rpm -ivh hp-snmp-agents-<version>.rpm</I></B></P>\n<P>パッケージが正しくロードされているか、以下をタイプして確認します。</P>\n<P>         <B><I>/etc/init.d/hp-snmp-agents status</I></B></P>\n<P>以下のコマンドを実行してヘルプを参照してください。</P>\n<P>         <B><I>man hp-snmp-agents</I></B></P>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE SNMP Agents for SUSE LINUX Enterprise Server 15"},{"lang":"ja","x_late":"HPE SNMPエージェントfor SUSE LINUX Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"3309","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3307","subdev":"3309","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-28T13:07:04","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>Addressed issue where the HPE Synergy 3820C 10/20Gb Converged Network Adapter was showing not supported</li>\n\t<li>Corrected invalid utf8mb4 char in database</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>TBD</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"}],"sw_keys":[{"name":"hp-snmp-agents","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWCPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTND7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5743504e","Version":"HPD7"},{"DeviceName":"EH000600JWCPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTND7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5743504c","Version":"HPD7"},{"DeviceName":"EH000300JWCPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTND7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5743504b","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EH000300JWCPK, EH000600JWCPL, and EH000900JWCPN"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：EH000300JWCPK、EH000600JWCPL、およびEH000900JWCPN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EH000300JWCPK, EH000600JWCPL&nbsp;and EH000900JWCPN Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"5651665","datemodified":"2021-07-23T08:22:04","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPD7-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPD7-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPD7-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPD7-2.1/CP048083.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPD7-2.1/SKESTND7.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPD7-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPD7-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPD7-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPD7-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048083.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048083.scexe"],"md5sum":"ecfc62d6fab4113513207e568a756b2e","name":"firmware-hdd-3d97759111-HPD7-2.1.x86_64.rpm","release":"2021-07-23T08:08:07","revision":"0","sha1sum":"15acdad7bdb2ad51c91b4653a92a2f0f990938d3","size":"5MB","target_guids":["452340a5-3048-3030-3930-304a5743504e","452340a5-3048-3030-3630-304a5743504c","452340a5-3048-3030-3330-304a5743504b"],"type_of_change":"1","version":"HPD7"}],"id":{"product":"eca7d77c8ba84ffe9014dfb5c3b6ee15","version":"78a7b4a2d74d4406a264b90ab1b79cbe"},"installation":{"command":"CP040309.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EH000300JWCPK, EH000600JWCPL and EH000900JWCPN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux(x64) - EH000300JWCPK、EH000600JWCPLおよびEH000900JWCPNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EH000300JWCPK","target_guid":"452340a5-3048-3030-3330-304a5743504b","type":"sas"},{"id":"EH000600JWCPL","target_guid":"452340a5-3048-3030-3630-304a5743504c","type":"sas"},{"id":"EH000900JWCPN","target_guid":"452340a5-3048-3030-3930-304a5743504e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T11:10:39","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH000300JWCPK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000900JWCPN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000600JWCPL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001000KWJSE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3030-304b574a5345","Version":"4ICDHPK1"},{"DeviceName":"VO002000KWJSF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3230-3030-304b574a5346","Version":"4ICDHPK1"},{"DeviceName":"VO004000KWJSH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3430-3030-304b574a5348","Version":"4ICDHPK1"},{"DeviceName":"VT004000KWJSU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3054-3430-3030-304b574a5355","Version":"4ICDHPK1"},{"DeviceName":"MO001600KWJSN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b574a534e","Version":"4ICDHPK1"},{"DeviceName":"MO003200KWJSQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b574a5351","Version":"4ICDHPK1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VO001000KWJSE, VO002000KWJSF, VO004000KWJSH, VT004000KWJSU, MO001600KWJSN and MO003200KWJSQ"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO001000KWJSE、VO002000KWJSF、VO004000KWJSH、VT004000KWJSU、 MO001600KWJSNおよびMO003200KWJSQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for VMware ESXi - VO001000KWJSE, VO002000KWJSF, VO004000KWJSH, VT004000KWJSU, MO001600KWJSN and MO003200KWJSQ Drives</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;4ICDHPK1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:&nbsp;</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>This firmware corrects the potential for a drive to become disabled and nonfunctional during certain conditions or workloads.</li>\n\t<li>After the drive is upgraded to firmware version HPK1, it cannot be downgraded to firmware version HPK0.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16394300","datemodified":"2021-08-27T04:57:40","file_list":["/CP048471_BUILD_2.data","/CP048471.vmexe","/CP048471.vmexe64","/CP048471.vmfile","/CP048471_VMw.zip","/CP048471.xml","/payload.json","/CP048471_VMw.zip/index.xml","/CP048471_VMw.zip/vendor-index.xml","/CP048471_VMw.zip/metadata.zip","/CP048471_VMw.zip/vib20/CP048471/HPE_bootbank_CP048471_4ICDHPK1.2-7.0.0.15843807.vib","/CP048471_VMw.zip/metadata.zip/vendor-index.xml","/CP048471_VMw.zip/metadata.zip/vmware.xml","/CP048471_VMw.zip/metadata.zip/vibs/CP048471--7735200043338282656.xml","/CP048471_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048471_4ICDHPK1.2-7.0.0.15843807.xml"],"md5sum":"3f5ba298fefa71768327fa3c2a224ab5","name":"CP048471.zip","release":"2021-08-27T04:52:13","revision":"0","sha1sum":"94c342d01b42b53837a1718340146bdbad0e837d","size":"15MB","target_guids":["562340a5-304f-3130-3030-304b574a5345","562340a5-304f-3230-3030-304b574a5346","562340a5-304f-3430-3030-304b574a5348","562340a5-3054-3430-3030-304b574a5355","4d2340a5-304f-3130-3630-304b574a534e","4d2340a5-304f-3330-3230-304b574a5351"],"type_of_change":"2","version":"4ICDHPK1","vib_list":[{"name":"CP048471","version":"4ICDHPK1.2-7.0.0.15843807"}]}],"id":{"product":"180a7c20ed0347b4a9c066f5e5cf116b","version":"34f4d91da4cb493596a44fb1ce39ac1b"},"installation":{"command":"CP042960.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi - VO001000KWJSE, VO002000KWJSF, VO004000KWJSH, VT004000KWJSU, MO001600KWJSN and MO003200KWJSQ Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - VO001000KWJSE、VO002000KWJSF、VO004000KWJSH、VT004000KWJSU、MO001600KWJSN、およびMO003200KWJSQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MO003200KWJSQ","target_guid":"4d2340a5-304f-3330-3230-304b574a5351","type":"nvme"},{"id":"VO002000KWJSF","target_guid":"562340a5-304f-3230-3030-304b574a5346","type":"nvme"},{"id":"MO001600KWJSN","target_guid":"4d2340a5-304f-3130-3630-304b574a534e","type":"nvme"},{"id":"VO001000KWJSE","target_guid":"562340a5-304f-3130-3030-304b574a5345","type":"nvme"},{"id":"VT004000KWJSU","target_guid":"562340a5-3054-3430-3030-304b574a5355","type":"nvme"},{"id":"VO004000KWJSH","target_guid":"562340a5-304f-3430-3030-304b574a5348","type":"nvme"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T16:01:55","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>This firmware corrects the potential for a drive to become disabled and nonfunctional during certain conditions or workloads.</li>\n\t<li>After the drive is upgraded to firmware version HPK1, it cannot be downgraded to firmware version HPK0.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This firmware corrects the potential for a drive to become disabled and nonfunctional during certain conditions or workloads.</li>\n\t<li>After the drive is upgraded to firmware version HPK1, it cannot be downgraded to firmware version HPK0.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO001000KWJSE","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO002000KWJSF","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO001600KWJSN","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO004000KWJSH","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO003200KWJSQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VT004000KWJSU","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300032","languages":[{"lang":"fr","x_late":"Pilote - Gestion du système"},{"lang":"en","x_late":"Driver - System Management"},{"lang":"cn","x_late":"驱动程序 - 系统管理"},{"lang":"tw","x_late":"驅動程式 ─ 系統管理"},{"lang":"de","x_late":"Treiber - Systemverwaltung"},{"lang":"ko","x_late":"드라이버 - 시스템 관리"},{"lang":"it","x_late":"Driver - Gestione sistema"},{"lang":"ja","x_late":"ドライバ - システム マネジメント"},{"lang":"es","x_late":"Controlador - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The iLO 4 Management Controller Driver Package provides system management support, including monitoring of server components, event logging, and support for the Insight Management Agents and WBEM Providers."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[],"files":[{"bytes":"764184","datemodified":"2018-12-03T12:24:19","file_list":["cp037927.xml","cpqsetup.exe","depcheck.dll","hpqilo3core.cat","hpqilo3core.inf","hpqilo3core.sys","hpqilo3service.cab","hpqilo3service.msi","install.xml","multisetup.dll"],"md5sum":"21e5fa3be54b9f929d3d88f74e9ec196","name":"cp037927.exe","release":"2018-12-03T18:23:28","revision":"0","sha1sum":"ae466f5773c646a45b34b3cc47f9dbf1b66c9fdd","size":"746KB","target_guids":[],"type_of_change":"0","version":"4.0.0.0"}],"id":{"product":"0304d65ecdff4ea58d39c91896e3e228","version":"e20968c891b444c6b6de68a73461ce32"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 3/4 Channel Interface Driver for Windows X64","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 3/4 Channel Interface Driver for Windows X64"}]}]}]},"installation_notes":[{"lang":"en","x_late":"Place the Smart Component in a temporary directory, then double-click it to run.<p>Select \"Install\" to start extracting to a temporary location on the hard drive.   <p>Click the \"Install\" button to perform the driver installation."},{"lang":"ja","x_late":"Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。<p>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。   <p>インストールボタンをクリックしてドライバーインストールを実行します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"iLO 4 Management Controller Driver Package for Windows Server 2016 and Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"1979","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3302","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-03-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Add support for Windows Server 2019.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fixed a component installation failure (error message &quot;The iLO 4 Core Driver must be installed before installing this package&quot;) when Windows Device Guard is enabled.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"}],"sw_keys":[{"name":"ProLiantMonitor.exe","sw_key_expectedpath":"%ProgramFiles%\\Hewlett-Packard\\iLO 3\\service"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Blade Emulex 10/20GbE Server Adapters running under VMware vSphere 6.7."},{"lang":"ja","x_late":"この製品には、VMware vSphere 6.7で動作するHPE Blade Emulex 10/20GbEサーバーアダプター用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;12.0.1216.4.</p>\n"}],"files":[{"bytes":"362271","datemodified":"2020-02-05T16:25:34","file_list":["/cp042920.xml","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/elxnet-12.0.1216.4-1OEM.670.0.0.8169922.x86_64.vib","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/doc/README.txt","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/doc/release_note_elxnet_12.0.1216.4-1OEM.670.0.0.8169922.xml","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/index.xml","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/vendor-index.xml","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/metadata.zip","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/vib20/elxnet/EMU_bootbank_elxnet_12.0.1216.4-1OEM.670.0.0.8169922.vib","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/metadata.zip/vmware.xml","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/metadata.zip/bulletins/VMW-ESX-6.7.0-elxnet-12.0.1216.4.xml","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/metadata.zip/vibs/elxnet--1134262900.xml"],"md5sum":"e0737390f016bd44de695feeb0de64b6","name":"cp042920.zip","release":"2020-02-05T22:24:05","revision":"0","sha1sum":"4940baedcb79e6d8886a99270224cb15d7bcb658","size":"353KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecbc5a6557"],"type_of_change":"0","version":"2020.03.09","vib_list":[{"name":"elxnet","version":"12.0.1216.4-1OEM.670.0.0.8169922"}]}],"id":{"product":"e420d2824f1a4f3980b18730d5e2bcc4","version":"3b510f5dfbf04414b2ce803a4d0454fe"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE Driver for VMware vSphere 6.7"},{"lang":"ja","x_late":"HPE Blade Emulex 10/20GbEドライバーfor VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-03-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product corrects&nbsp;a vmnic flapping issue which impacts network&nbsp;connectivity.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"elxnet:12.0.1216.4-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWZJF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304a575a4a46","Version":"HPD4"},{"DeviceName":"VO001920JWZJH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304a575a4a48","Version":"HPD4"},{"DeviceName":"VO003840JWZJK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304a575a4a4b","Version":"HPD4"},{"DeviceName":"VO007680JWZJL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304a575a4a4c","Version":"HPD4"},{"DeviceName":"VO015360JWZJN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3336-304a575a4a4e","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN"},{"lang":"ja","x_late":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO000960JWZJF、VO001920JWZJH、VO003840JWZJK、VO007680JWZJL、およびVO015360JWZJN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp; &nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"3198104","datemodified":"2021-07-26T06:30:44","file_list":["cp048466.xml","cpqsetup.exe","GPM1643ASAD4.rel","payload.json","setup.dll"],"md5sum":"c7b423ef001ddfd3729f4a969ae43b0b","name":"cp048466.exe","release":"2021-07-26T06:23:05","revision":"0","sha1sum":"b90bfe0f439e1853d9d75eccaba04c64ae577a71","size":"3MB","target_guids":["562340a5-304f-3030-3936-304a575a4a46","562340a5-304f-3130-3932-304a575a4a48","562340a5-304f-3330-3834-304a575a4a4b","562340a5-304f-3730-3638-304a575a4a4c","562340a5-304f-3531-3336-304a575a4a4e"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"e5d8389759aa4832a8475a2ff763f16b","version":"d7fcf5ecbebc4858aba47c20e26a207c"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows（x64）- VO000960JWZJF、VO001920JWZJH、VO003840JWZJK、 VO007680JWZJLおよびVO015360JWZJNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VO015360JWZJN","target_guid":"562340a5-304f-3531-3336-304a575a4a4e","type":"sas"},{"id":"VO007680JWZJL","target_guid":"562340a5-304f-3730-3638-304a575a4a4c","type":"sas"},{"id":"VO003840JWZJK","target_guid":"562340a5-304f-3330-3834-304a575a4a4b","type":"sas"},{"id":"VO001920JWZJH","target_guid":"562340a5-304f-3130-3932-304a575a4a48","type":"sas"},{"id":"VO000960JWZJF","target_guid":"562340a5-304f-3030-3936-304a575a4a46","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T13:05:26","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Modify Drive Vendor Identification String (VID) in Inquiry page from &ldquo;HP&rdquo; to &ldquo;HPE&rdquo;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO015360JWZJN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO007680JWZJL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920JWZJH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000960JWZJF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003840JWZJK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"此元件套件包含適用於 Microsoft Windows Server 2016 執行的 HPE Intel i40ea 10 Gigabit 乙太網路 NIC 驅動程式。"},{"lang":"en","x_late":"This Component Package contains the drivers for HPE Intel i40ea 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2016."},{"lang":"ko","x_late":"이 구성 요소 패키지에는 Microsoft Windows Server 2016에서 실행되는 HPE Intel i40ea 10기가비트 이더넷 NIC용 드라이버가 포함되어 있습니다."},{"lang":"cn","x_late":"此组件包包含的驱动程序适用于在 Microsoft Windows Server 2016 环境下运行的 HPE Intel i40ea 10 千兆以太网卡。"},{"lang":"ja","x_late":"このコンポーネントパッケージは、Microsoft Windows Server 2016で動作しているHPE Intel i40ea 10 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1252816","datemodified":"2021-01-08T16:05:03","file_list":["cp045125.xml","cpqsetup.exe","cp_data.xml","i40ea65.cat","i40ea65.din","i40ea65.inf","i40ea65.sys","i40eamsg.dll","install.xml","nicco5.dll","nicdrvr.dll","NicInI40.dll"],"md5sum":"3ea569e075f0ada18b9dc4833d5052f3","name":"cp045125.exe","release":"2021-01-08T15:51:05","revision":"0","sha1sum":"e82538aaaa9fe11bb47799f71768b220db3c3270","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3bb214b3"],"type_of_change":"0","version":"1.13.104.0"}],"id":{"product":"4c78cfc099d944a5b3790aa796ed8a49","version":"225b70c27c564e63ae180960589bf693"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Windows Server 2016 的 HPE Intel i40ea 驅動程式"},{"lang":"en","x_late":"HPE Intel i40ea Driver for Windows Server 2016"},{"lang":"ko","x_late":"Windows Server 2016용 HPE Intel i40ea 드라이버"},{"lang":"cn","x_late":"Windows Server 2016 版 HPE Intel i40ea 驱动程序"},{"lang":"ja","x_late":"HPE Intel i40eaドライバー for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"1572","subdev":"0000","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"158A","subdev":"0000","subven":"1590","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product added implementation of Advanced Link Speed functionality in Physical Function (PF) driver that are supports dynamic link speed changes.</p>\n","latest_fixes_x_late":"<ul>\n\t<li>This product correct an issue which Blue Screen of Death （BSOD） (0x133) occurred with Remote Access Role service during shutdown.</li>\n\t<li>This product correct an issue which system crashed after few modifying Intel&reg; Advanced Network Services (Intel&reg; ans) Team type with tagged Virtual Local Area Network (VLAN).</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product corrects an traffic packets making cert failure seen when packets transferred to VLAN after RDMA function enabled.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"i40ea65.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH0600JDYTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFL4CD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3630-304a4459544e","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: EH0600JDYTN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EH0600JDYTN Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong></p>\n\n<ul>\n\t<li>Fixes a data integrity risk where stale data is mistakenly used from cache.</li>\n\t<li>Fixes a data integrity risk where stale data is returned on an unaligned overlapped write-read operation.</li>\n\t<li>Fixes a data integrity risk during a sequential read and write workload when a recovered error is encountered, which could cause incomplete data to be read.&nbsp;</li>\n</ul>\n\n<p><br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp; &nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;&nbsp; None.</p>\n"}],"files":[{"bytes":"5569352","datemodified":"2021-07-23T08:16:20","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-f3faa195ff-HPD7-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-f3faa195ff-HPD7-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-f3faa195ff-HPD7-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-f3faa195ff-HPD7-8.1/CP048090.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-f3faa195ff-HPD7-8.1/HKFL4CD7.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-f3faa195ff-HPD7-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-f3faa195ff-HPD7-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-f3faa195ff-HPD7-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-f3faa195ff-HPD7-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048090.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048090.scexe"],"md5sum":"5912bd1fc0c002633cb23769263dd7f1","name":"firmware-hdd-f3faa195ff-HPD7-8.1.x86_64.rpm","release":"2021-07-23T08:03:20","revision":"0","sha1sum":"0d1f27a09f5c45c663fa19ed3199df7e43cbb3e0","size":"5MB","target_guids":["002340a5-4500-3048-3630-304a4459544e"],"type_of_change":"2","version":"HPD7"}],"id":{"product":"dc8e1d549b6c46c4a9bd046b4dd1950e","version":"0f3cda86587e4bed849bb4f9006f7f81"},"installation":{"command":"CP040340.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EH0600JDYTN Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - EH0600JDYTNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"EH0600JDYTN","target_guid":"002340a5-4500-3048-3630-304a4459544e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T11:44:30","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Fixes a data integrity risk where stale data is mistakenly used from cache.</li>\n\t<li>Fixes a data integrity risk where stale data is returned on an unaligned overlapped write-read operation.</li>\n\t<li>Fixes a data integrity risk during a sequential read and write workload when a recovered error is encountered, which could cause incomplete data to be read.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Fixes a data integrity risk where stale data is mistakenly used from cache.</li>\n\t<li>Fixes a data integrity risk where stale data is returned on an unaligned overlapped write-read operation.</li>\n\t<li>Fixes a data integrity risk during a sequential read and write workload when a recovered error is encountered, which could cause incomplete data to be read.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH0600JDYTN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWEBH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBUGD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a57454248","Version":"HPD5"},{"DeviceName":"EG000300JWEBF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBUGD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57454246","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EG000600JWEBH and EG000300JWEBF"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EG000600JWEBHおよびEG000300JWEBF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG000600JWEBH and EG000300JWEBF Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"17505193","datemodified":"2021-08-30T07:45:07","file_list":["/CP049345_BUILD_3.data","/CP049345.vmexe","/CP049345.vmexe64","/CP049345.vmfile","/CP049345_VMw.zip","/CP049345.xml","/payload.json","/CP049345_VMw.zip/index.xml","/CP049345_VMw.zip/vendor-index.xml","/CP049345_VMw.zip/metadata.zip","/CP049345_VMw.zip/vib20/CP049345/HPE_bootbank_CP049345_HPD5.3-7.0.0.15843807.vib","/CP049345_VMw.zip/metadata.zip/vendor-index.xml","/CP049345_VMw.zip/metadata.zip/vmware.xml","/CP049345_VMw.zip/metadata.zip/vibs/CP049345-2934946384033608441.xml","/CP049345_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049345_HPD5.3-7.0.0.15843807.xml"],"md5sum":"78ef42c11d6ca7bbbc54e9c2072dff12","name":"CP049345.zip","release":"2021-08-30T07:40:03","revision":"0","sha1sum":"6f13ecb6d9ab1fb83671f56521ebc9c6d9456019","size":"16MB","target_guids":["452340a5-3047-3030-3630-304a57454248","452340a5-3047-3030-3330-304a57454246"],"type_of_change":"1","version":"HPD5","vib_list":[{"name":"CP049345","version":"HPD5.3-7.0.0.15843807"}]}],"id":{"product":"2fe8cdf1119641378a716d37c5e433f7","version":"3a76ed3bdd304961937a09e1718b779f"},"installation":{"command":"CP040661.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>HP Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - EG000600JWEBH and EG000300JWEBF Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - EG000600JWEBHおよびEG000300JWEBFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG000300JWEBF","target_guid":"452340a5-3047-3030-3330-304a57454246","type":"sas"},{"id":"EG000600JWEBH","target_guid":"452340a5-3047-3030-3630-304a57454248","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-25T11:41:35","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG000600JWEBH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG000300JWEBF","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH0300JEDHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SVKBPND4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3330-304a45444843","Version":"HPD4"},{"DeviceName":"EH0450JEDHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SVKBPND4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3435-304a45444844","Version":"HPD4"},{"DeviceName":"EH0600JEDHE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SVKBPND4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3630-304a45444845","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EH0300JEDHC, EH0450JEDHD and EH0600JEDHE"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EH0300JEDHC、EH0450JEDHDおよびEH0600JEDHE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EH0300JEDHC, EH0450JEDHD&nbsp;and EH0600JEDHE Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5415019","datemodified":"2021-07-23T08:15:48","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8c4a212ff9-HPD4-9.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8c4a212ff9-HPD4-9.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8c4a212ff9-HPD4-9.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8c4a212ff9-HPD4-9.1/CP048089.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8c4a212ff9-HPD4-9.1/SVKBPND4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8c4a212ff9-HPD4-9.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8c4a212ff9-HPD4-9.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8c4a212ff9-HPD4-9.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8c4a212ff9-HPD4-9.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048089.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048089.scexe"],"md5sum":"48809f678313c94ca16424804a84e88d","name":"firmware-hdd-8c4a212ff9-HPD4-9.1.x86_64.rpm","release":"2021-07-23T08:03:23","revision":"0","sha1sum":"aa19f57ea616e766cd69db5df482e678e7bce4ce","size":"5MB","target_guids":["002340a5-4500-3048-3330-304a45444843","002340a5-4500-3048-3435-304a45444844","002340a5-4500-3048-3630-304a45444845"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"62bd64385d4642c4adfd6fdae64666cb","version":"a42a36e975974b6e9adef119d042b34e"},"installation":{"command":"CP040263.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EH0300JEDHC, EH0450JEDHD and EH0600JEDHE Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux(x64) - EH0300JEDHC、EH0450JEDHDおよびEH0600JEDHEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EH0300JEDHC","target_guid":"002340a5-4500-3048-3330-304a45444843","type":"sas"},{"id":"EH0450JEDHD","target_guid":"002340a5-4500-3048-3435-304a45444844","type":"sas"},{"id":"EH0600JEDHE","target_guid":"002340a5-4500-3048-3630-304a45444845","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T11:37:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH0600JEDHE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0300JEDHC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0450JEDHD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the iSCSI driver for the HPE Emulex 10/20GbE Server Adapters running under VMware vSphere 6.5."},{"lang":"ja","x_late":"この製品は、VMware vSphere 6.5上で動作するHPE Emulex 10/20GbEサーバーアダプターのためのiSCSIドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;12.0.1108.0.</p>\n"},{"lang":"ja","x_late":"<p>この製品には、ドライバーバージョン12.0.1108.0が含まれています。</p>\n"}],"files":[{"bytes":"3343325","datemodified":"2020-06-11T04:21:05","file_list":["/cp044543.xml","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/elxiscsi-12.0.1108.0-1OEM.650.0.0.4598673.x86_64.vib","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/ELX-ESX-libelxima.so-12.0.1108.0.vib","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/doc/README.txt","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/doc/release_note_elxiscsi_12.0.1108.0-1OEM.650.0.0.4598673.txt","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/index.xml","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/vendor-index.xml","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/metadata.zip","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/vib20/elx-esx-libelxima.so/ELX_bootbank_elx-esx-libelxima.so_12.0.1108.0-03.vib","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/vib20/elxiscsi/EMU_bootbank_elxiscsi_12.0.1108.0-1OEM.650.0.0.4598673.vib","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/metadata.zip/vmware.xml","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0.xml","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/metadata.zip/vibs/elx-esx-libelxima.so--741715821.xml","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/metadata.zip/vibs/elxiscsi--787023163.xml"],"md5sum":"69d45074ffc53654621999495e48e277","name":"cp044543.zip","release":"2020-06-11T04:20:05","revision":"0","sha1sum":"66e2c3ea4389eac2e20d962051e094899220d657","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb358b4ee","20a6e8e4-bf33-4c71-a6bf-d9ec1c488a85"],"type_of_change":"0","version":"2020.09.14","vib_list":[{"name":"elx-esx-libelxima.so","version":"12.0.1108.0-03"},{"name":"elxiscsi","version":"12.0.1108.0-1OEM.650.0.0.4598673"}]}],"id":{"product":"21671a6ff3c64fa1be71c992a0903728","version":"bafcd3494cbc44a3bf3b9aaa241ffacf"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバーにUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex 10/20GbE iSCSI Driver for VMware vSphere 6.5"},{"lang":"ja","x_late":"HPE Emulex 10/20GbE iSCSIドライバーfor VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"0722","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c220a","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c21d4","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c8144","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072215908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-11T01:46:41","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue ESXi lib naming convention in iscsi driver packages caused payload conflict for ESXi 6.5.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"elxiscsi:12.0.1108.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"},{"name":"elx-esx-libelxima.so:12.0.1108.0-03","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG1800JFHMH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SEED8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3830-304a46484d48","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: EG1800JFHMH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - &nbsp;EG1800JFHMH Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD7<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"4906849","datemodified":"2021-07-23T08:24:15","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-7fc5497116-HPD8-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-7fc5497116-HPD8-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-7fc5497116-HPD8-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7fc5497116-HPD8-2.1/CP048082.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-7fc5497116-HPD8-2.1/T14SEED8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-7fc5497116-HPD8-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7fc5497116-HPD8-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-7fc5497116-HPD8-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-7fc5497116-HPD8-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048082.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048082.scexe"],"md5sum":"4e401886fa3101cfbe0fff095353c52e","name":"firmware-hdd-7fc5497116-HPD8-2.1.x86_64.rpm","release":"2021-07-23T08:12:05","revision":"0","sha1sum":"0eb3642989662c23c97ff5797debb5267cea5497","size":"4MB","target_guids":["002340a5-4500-3147-3830-304a46484d48"],"type_of_change":"1","version":"HPD8"}],"id":{"product":"07f321e61ae446eba28c1b93476d5170","version":"c08069df7aa44afdbd2d5d82a876c683"},"installation":{"command":"CP040318.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EG1800JFHMH Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - EG1800JFHMHドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EG1800JFHMH","target_guid":"002340a5-4500-3147-3830-304a46484d48","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T11:05:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>A low-probability, high severity corner case of sustained outer-diameter activity with emergency power off when heads are at the outer diameter prevented heads from parking/latching properly on a few drives in the field.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG1800JFHMH","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware for mezzanine Converged Network adapters."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"29514385","datemodified":"2021-08-27T05:50:00","file_list":["./usr/lib/x86_64-linux-gnu/firmware-cna-mezz-emulex-2021.10.01-1.7","./usr/lib/x86_64-linux-gnu/firmware-cna-mezz-emulex-2021.10.01-1.7/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-cna-mezz-emulex-2021.10.01-1.7/.setup","./usr/lib/x86_64-linux-gnu/firmware-cna-mezz-emulex-2021.10.01-1.7/CP048527.xml","./usr/lib/x86_64-linux-gnu/firmware-cna-mezz-emulex-2021.10.01-1.7/brcmflashStandalone-linux-12.0.1345.0-1.zip","./usr/lib/x86_64-linux-gnu/firmware-cna-mezz-emulex-2021.10.01-1.7/firmware","./usr/lib/x86_64-linux-gnu/firmware-cna-mezz-emulex-2021.10.01-1.7/firmware/oc14-12.0.1345.0.ufi","./usr/lib/x86_64-linux-gnu/firmware-cna-mezz-emulex-2021.10.01-1.7/fwmatrix.txt","./usr/lib/x86_64-linux-gnu/firmware-cna-mezz-emulex-2021.10.01-1.7/hpe_fw_matrix.xml","./usr/lib/x86_64-linux-gnu/firmware-cna-mezz-emulex-2021.10.01-1.7/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-cna-mezz-emulex-2021.10.01-1.7/payload.json","./usr/lib/x86_64-linux-gnu/firmware-cna-mezz-emulex-2021.10.01-1.7/readme.txt","./usr/lib/x86_64-linux-gnu/firmware-cna-mezz-emulex-2021.10.01-1.7/reference.xml","./usr/lib/x86_64-linux-gnu/firmware-cna-mezz-emulex-2021.10.01-1.7/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048527.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048527.scexe"],"md5sum":"9e32c7af1bb85b80f5b398a4f1d14cf1","name":"firmware-cna-mezz-emulex-2021.10.01-1.7.x86_64.rpm","release":"2021-08-27T05:39:03","revision":"0","sha1sum":"33ca9627e251ce4f714f6d5fbf7f1bae6a3ea06e","size":"28MB","target_guids":[],"type_of_change":"1","version":"2021.10.01"}],"id":{"product":"8d423bf53f3a43f5bf8c7f37aaba6c39","version":"cd4fb687fc004b58ae0e552824ae3130"},"installation":{"command":"installer","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Firmware installation is a two-step process.&nbsp; Install the firmware installation tool rpm, then execute the installed tool to update the firmware.<br />\n&nbsp;<br />\n&nbsp;1. Install the firmware installation tool:&nbsp; rpm -Uhv &lt;rpm_package_name&gt;.rpm&nbsp; This extracts the firmware installation tool to /usr/lib/x86_64-linux-gnu (64-bit systems)&nbsp;</p>\n\n<p>&nbsp;2. cd to the appropriate location for your system, and update the firmware by executing ./.setup<br />\n&nbsp;<br />\n&nbsp;When the firmware installation completes, you may remove the firmware installation tool from your system using the rpm -e command: rpm -e &lt;rpm_package_name&gt;.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Firmware Flash for Emulex Mezzanine Converged Network Adapters for Linux (x64)"}],"prerequisites":{"required_diskspace":{"size_kb":"20000"},"supported_devices":[{"dev":"0724","subdev":"1935","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1935","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1934","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"1934","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T10:38:36","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p dir=\"LTR\">We&nbsp;have separate components to update fibre channel and converged network adapters.&nbsp; This is a converged network adapter update component.</p>\n\n<p dir=\"LTR\">This component is only supported on RHEL7u8, RHEL7u9, RHEL8u3, SLES12SP5, SLES15SP2 OS&#39;s.<br />\n<br />\nUpdated CNA (XE100 series) firmware&nbsp;</p>\n\n<p>This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 20Gb 2-port 650FLB Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1345.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 20Gb 2-port 650M Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1345.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"emulex_cna","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"VMware vSphere 6.5 Fibre Channel Driver kit for HPE Emulex Mezzanine Host Bus Adapters(HBAs)"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"1467806","datemodified":"2021-08-26T11:40:50","file_list":["/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip","/cp048584.xml","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/lpfc-12.8.317.0-1OEM.650.0.0.4598673.x86_64.vib","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/doc/README.txt","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/doc/release_note_lpfc_12.8.317.0-1OEM.650.0.0.4598673.txt","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/index.xml","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/vendor-index.xml","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/metadata.zip","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/vib20/lpfc/EMU_bootbank_lpfc_12.8.317.0-1OEM.650.0.0.4598673.vib","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/metadata.zip/vmware.xml","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-lpfc-12.8.317.0.xml","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/metadata.zip/vibs/lpfc--3610581689307200678.xml"],"md5sum":"6c4cfbe29256e050709a2832b4b12f1d","name":"cp048584.zip","release":"2021-08-26T11:40:05","revision":"0","sha1sum":"cfd77713231708957e1e9b773c3daf4318fcb1ff","size":"1MB","target_guids":[],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"lpfc","version":"12.8.317.0-1OEM.650.0.0.4598673"}]}],"id":{"product":"690d33dabb4f474f983a0ef42b752be8","version":"5b7551c99718494ea43e879209e17dcf"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware Vsphere Update Manager(VUM) or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on Vsphere Update Manager(VUM) and the esxcli commands</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Emulex Mezzanine Fibre Channel driver component for VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T09:15:55","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p dir=\"LTR\"><strong>Added the following:-</strong></p>\n\n<ul>\n\t<li>Changed the default Logical Unit Number (LUN) queue depth from 30 to 64</li>\n\t<li>Added Non-volatile memory express (NVMe) over Fibre Channel (FC) capability&nbsp;&nbsp;</li>\n</ul>\n\n<p dir=\"LTR\">Updated to Driver version 12.8.317.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"lpfc:12.8.317.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG1800JEMDB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBT2D5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3830-304a454d4442","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: EG1800JEMDB"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EG1800JEMDB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG1800JEMDB Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"17741677","datemodified":"2021-08-30T05:54:01","file_list":["/CP048266_BUILD_4.data","/CP048266.vmexe","/CP048266.vmexe64","/CP048266.vmfile","/CP048266_VMw.zip","/CP048266.xml","/payload.json","/CP048266_VMw.zip/index.xml","/CP048266_VMw.zip/vendor-index.xml","/CP048266_VMw.zip/metadata.zip","/CP048266_VMw.zip/vib20/CP048266/HPE_bootbank_CP048266_HPD5.4-7.0.0.15843807.vib","/CP048266_VMw.zip/metadata.zip/vendor-index.xml","/CP048266_VMw.zip/metadata.zip/vmware.xml","/CP048266_VMw.zip/metadata.zip/vibs/CP048266-3589537419090905739.xml","/CP048266_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048266_HPD5.4-7.0.0.15843807.xml"],"md5sum":"9b9567d5046cf7d978d6189ab1c399c8","name":"CP048266.zip","release":"2021-08-30T05:48:46","revision":"0","sha1sum":"7396785ec0365ab9e2ce64586e779c98ebd6afd3","size":"16MB","target_guids":["002340a5-4500-3147-3830-304a454d4442"],"type_of_change":"1","version":"HPD5","vib_list":[{"name":"CP048266","version":"HPD5.4-7.0.0.15843807"}]}],"id":{"product":"8881b9f92866499daac317541d2299ed","version":"1e7f7b92dd0b48acbb207d7d4fa53658"},"installation":{"command":"CP040573.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EG1800JEMDB Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EG1800JEMDBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG1800JEMDB","target_guid":"002340a5-4500-3147-3830-304a454d4442","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-02T12:54:34","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG1800JEMDB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"本產品包含適用於在 SUSE Linux Enterprise Server 12 x86_64 下執行之 HPE Broadcom 乙太網路網路卡的驅動程式。"},{"lang":"en","x_late":"This product contains the drivers for the HPE Broadcom Ethernet NICs running under SUSE Linux Enterprise Server 12 x86_64."},{"lang":"ko","x_late":"이 제품에는 SUSE Linux Enterprise Server 12 x86_64에서 실행 중인 HPE Broadcom 이더넷 NIC용 드라이버가 포함되어 있습니다."},{"lang":"cn","x_late":"本产品包含适用于在 SUSE Linux Enterprise Server 12 x86_64 下方运行的 HPE Broadcom 以太网网卡驱动程序。"},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12 x86_64で動作するHPE Broadcom Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"124725","datemodified":"2021-01-17T06:54:11","file_list":["./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/tg3.ko","./usr/share/smartupdate/tg3-kmp-default/component.xml"],"md5sum":"68a3400416c6f5095b3e711df61e698e","name":"tg3-kmp-default-3.139b_k4.12.14_94.41-2.sles12sp4.x86_64.rpm","release":"2021-01-17T06:50:04","revision":"0","sha1sum":"5f803a3210ccde538583d537b291b248a0bfeafe","size":"121KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a"],"type_of_change":"0","version":"3.139b-2"},{"bytes":"112576","datemodified":"2021-01-17T06:56:21","file_list":["./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/tg3.ko","./usr/share/smartupdate/tg3-kmp-default/component.xml"],"md5sum":"62b170947f01ba77c3e183d89dfdfae9","name":"tg3-kmp-default-3.139b_k4.12.14_120-2.sles12sp5.x86_64.rpm","release":"2021-01-17T06:50:04","revision":"0","sha1sum":"2f8684ab9e2258a4d8afe13b2a9b9e87ba76e53b","size":"109KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a"],"type_of_change":"0","version":"3.139b-2"}],"id":{"product":"446098f1e7d240bb85aed0cf4ebd644e","version":"4878a8e954c44a2b85bbd83102b82f62"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 SUSE Linux Enterprise Server 12 x86_64 的 HPE Broadcom tg3 Ethernet 驅動程式"},{"lang":"en","x_late":"HPE Broadcom tg3 Ethernet Drivers for SUSE Linux Enterprise Server 12 x86_64"},{"lang":"ko","x_late":"SUSE Linux Enterprise Server 12 x86_64용 HPE Broadcom tg3 이더넷 드라이버"},{"lang":"cn","x_late":"适用于 SUSE Linux Enterprise Server 12 x86_64 的 HPE Broadcom tg3 以太网驱动程序"},{"lang":"ja","x_late":"HPE Broadcom tg3 Ethernetドライバー for SUSE Linux Enterprise Server 12 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"165F","subdev":"22E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c22e8","type":"pci","ven":"14E4"},{"dev":"1665","subdev":"22BD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1665103c22bd","type":"pci","ven":"14E4"},{"dev":"165F","subdev":"1786","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c1786","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"169D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c169d","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"3383","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c3383","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"22BE","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c22be","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 12 SP5.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>The products fixes an a race condition issue where driver will still try to access the PHY(physical layer) although it was already brought down when the tg3 timer fires</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"tg3-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"tg3-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"tg3-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"tg3-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for supported HPE Mellanox adapter cards."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"22365","datemodified":"2021-07-21T06:35:38","file_list":["./lib/modules/5.3.18-57-default","./lib/modules/5.3.18-57-default/updates","./lib/modules/5.3.18-57-default/updates/mst_pci.ko","./lib/modules/5.3.18-57-default/updates/mst_pciconf.ko","./usr/share/smartupdate/kernel-mft-mlnx-kmp-default/component.xml"],"md5sum":"3aff0a4058cc50410aaa07c430e580ac","name":"kernel-mft-mlnx-kmp-default-4.17.0_k5.3.18_57-1.sles15sp3.x86_64.rpm","release":"2021-07-21T06:19:03","revision":"0","sha1sum":"89c1d94927e6ca9e04260a54580246922d25c8ed","size":"21KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"type_of_change":"1","version":"4.17"},{"bytes":"10001284","datemodified":"2021-07-21T06:29:56","file_list":["./etc/bash_completion.d/mft/mft_base_autocomplete","./etc/bash_completion.d/mft/mft_help_to_completion.py","./etc/init.d/mst","./etc/mft/RPMS/mft","./etc/mft/mft.conf","./etc/mft/mst.conf","./usr/bin/flint","./usr/bin/flint_ext","./usr/bin/mcra","./usr/bin/mdevices_info","./usr/bin/mft_uninstall.sh","./usr/bin/minit","./usr/bin/mlxfwreset","./usr/bin/mlxfwstress","./usr/bin/mlxfwstress_ext","./usr/bin/mlxgearbox","./usr/bin/mlxpci","./usr/bin/mlxprivhost","./usr/bin/mst","./usr/bin/mst_cable","./usr/bin/mst_ib_add","./usr/bin/mstop","./usr/bin/resourcedump","./usr/bin/resourceparse","./usr/bin/stedump","./usr/share/man/man1","./usr/share/man/man1/flint.1.gz","./usr/share/man/man1/mcra.1.gz","./usr/share/man/man1/mdevices_info.1.gz","./usr/share/man/man1/minit.1.gz","./usr/share/man/man1/mlxfwreset.1.gz","./usr/share/man/man1/mst.1.gz","./usr/share/man/man1/mstop.1.gz","./usr/share/mft/fw_stress_db","./usr/share/mft/fw_stress_db/stress_types.db","./usr/share/mft/prm_dbs","./usr/share/mft/prm_dbs/hca","./usr/share/mft/prm_dbs/hca/ext","./usr/share/mft/prm_dbs/hca/ext/register_access_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.dat","./usr/share/mft/prm_dbs/switch","./usr/share/mft/prm_dbs/switch/ext","./usr/share/mft/prm_dbs/switch/ext/register_access_table.adb","./usr/share/mft/prm_dbs/switch/ext/register_access_table.dat","./usr/share/smartupdate/mft/component.xml"],"md5sum":"590149b824b5f46211d91b8e52fc54b4","name":"mft-4.17.0-106.sles15sp3.x86_64.rpm","release":"2021-07-21T06:19:03","revision":"0","sha1sum":"f06707ba597b0acf9706c47b424d2a9cbd9bf99a","size":"9MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"type_of_change":"1","version":"4.17"}],"id":{"product":"1ba987f68f464ccdb12940d5adec7c53","version":"26ccbe6f345d48bd94a131e512e2572b"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\nTo install or upgrade the driver:<br />\n<br />\nIf using 5.3.18.57-default kernel or any future errata:<br />\n<strong># rpm -Uvh kernel-mft-mlnx-kmp-default-4.17.0_k5.3.18_57-1.sles15sp2.x86_64.rpm&nbsp;&nbsp;mft-4.17.0-64.sles15sp2.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for SUSE Linux Enterprise Server 15 SP3 (AMD64/EM64T)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"101f","subdev":"0012","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30012","type":"pci","ven":"15b3"},{"dev":"101f","subdev":"0007","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30007","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T18:00:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","curr_fixes_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"kernel-mft-mlnx-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mft","sw_key_expectedpath":"software:rpm"},{"name":"kernel-mft-mlnx-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mft","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400PXDBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AL4HPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-305058444251","Version":"HPD1"},{"DeviceName":"EO000800PXDCK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AL4HPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-30505844434b","Version":"HPD1"},{"DeviceName":"EO001600PXDCH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AL4HPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-305058444348","Version":"HPD1"},{"DeviceName":"MO000800PXDBP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AL4HPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-305058444250","Version":"HPD1"},{"DeviceName":"MO001600PXDCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AL4HPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-305058444343","Version":"HPD1"},{"DeviceName":"MO003200PXDCD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AL4HPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-305058444344","Version":"HPD1"},{"DeviceName":"MO006400PXDCE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AL4HPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-305058444345","Version":"HPD1"},{"DeviceName":"VO000960PXDBN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AL4HPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-30505844424e","Version":"HPD1"},{"DeviceName":"VO001920PXDBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AL4HPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-305058444252","Version":"HPD1"},{"DeviceName":"VO003840PXDBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AL4HPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-305058444254","Version":"HPD1"},{"DeviceName":"VO007680PXDBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AL4HPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-305058444255","Version":"HPD1"},{"DeviceName":"VO015300PXDBV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AL4HPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3330-305058444256","Version":"HPD1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5591856","datemodified":"2021-07-27T16:45:22","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD1-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD1-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD1-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD1-2.1/CP049163.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD1-2.1/TAPM6AL4HPD1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD1-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD1-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD1-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD1-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049163.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049163.scexe"],"md5sum":"7df5f70394d41f0f056569c60b811427","name":"firmware-hdd-42aff4675b-HPD1-2.1.x86_64.rpm","release":"2021-07-27T16:32:06","revision":"0","sha1sum":"8504eb4cc251064a7c0241b2bd3452897b450d98","size":"5MB","target_guids":["452340a5-304f-3030-3430-305058444251","452340a5-304f-3030-3830-30505844434b","452340a5-304f-3130-3630-305058444348","4d2340a5-304f-3030-3830-305058444250","4d2340a5-304f-3130-3630-305058444343","4d2340a5-304f-3330-3230-305058444344","4d2340a5-304f-3630-3430-305058444345","562340a5-304f-3030-3936-30505844424e","562340a5-304f-3130-3932-305058444252","562340a5-304f-3330-3834-305058444254","562340a5-304f-3730-3638-305058444255","562340a5-304f-3531-3330-305058444256"],"type_of_change":"1","version":"HPD1"}],"id":{"product":"74085bfad3ea4badb1e5c0235f47c1ea","version":"32adc328bb294e6c998166e7d876b1b9"},"installation":{"command":"CP041670.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EO000800PXDCK","target_guid":"452340a5-304f-3030-3830-30505844434b","type":"sas"},{"id":"MO000800PXDBP","target_guid":"4d2340a5-304f-3030-3830-305058444250","type":"sas"},{"id":"EO000400PXDBQ","target_guid":"452340a5-304f-3030-3430-305058444251","type":"sas"},{"id":"EO001600PXDCH","target_guid":"452340a5-304f-3130-3630-305058444348","type":"sas"},{"id":"MO001600PXDCC","target_guid":"4d2340a5-304f-3130-3630-305058444343","type":"sas"},{"id":"MO006400PXDCE","target_guid":"4d2340a5-304f-3630-3430-305058444345","type":"sas"},{"id":"VO007680PXDBU","target_guid":"562340a5-304f-3730-3638-305058444255","type":"sas"},{"id":"VO001920PXDBR","target_guid":"562340a5-304f-3130-3932-305058444252","type":"sas"},{"id":"MO003200PXDCD","target_guid":"4d2340a5-304f-3330-3230-305058444344","type":"sas"},{"id":"VO015300PXDBV","target_guid":"562340a5-304f-3531-3330-305058444256","type":"sas"},{"id":"VO000960PXDBN","target_guid":"562340a5-304f-3030-3936-30505844424e","type":"sas"},{"id":"VO003840PXDBT","target_guid":"562340a5-304f-3330-3834-305058444254","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-27T16:28:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO007680PXDBU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO001600PXDCH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920PXDBR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000800PXDCK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200PXDCD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003840PXDBT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO015300PXDBV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000960PXDBN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600PXDCC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000400PXDBQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO006400PXDCE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800PXDBP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains be2net drivers for the HPE Emulex 10/20GbE Server Adapters running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 8で動作するHPE Emulex 10/20GbE サーバーアダプター用のbe2netドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"104097","datemodified":"2021-01-14T07:28:07","file_list":["./etc/depmod.d/be2net.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/be2net","./lib/modules/4.18.0-240.el8.x86_64/extra/be2net/be2net.ko","./usr/share/smartupdate/kmod-be2net/component.xml"],"md5sum":"c65312308995a9987c35456d7e66344c","name":"kmod-be2net-12.0.1342.0-1.rhel8u3.x86_64.rpm","release":"2021-01-14T07:19:04","revision":"0","sha1sum":"e78856c4655f4915586cb652ef7ba358d9933549","size":"101KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec6bd37e40"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"104185","datemodified":"2021-01-14T07:31:41","file_list":["./etc/depmod.d/be2net.conf","./lib/modules/4.18.0-193.el8.x86_64","./lib/modules/4.18.0-193.el8.x86_64/extra","./lib/modules/4.18.0-193.el8.x86_64/extra/be2net","./lib/modules/4.18.0-193.el8.x86_64/extra/be2net/be2net.ko","./usr/share/smartupdate/kmod-be2net/component.xml"],"md5sum":"6ac2fcd892c5adf66e0a4f8489147939","name":"kmod-be2net-12.0.1342.0-1.rhel8u2.x86_64.rpm","release":"2021-01-14T07:19:04","revision":"0","sha1sum":"895872217e5fe34b6726e35585615ab5316c88a2","size":"101KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec6bd37e40"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"e7ac9bd0dae24b7e9605737bb695f64d","version":"6b10913d6c864a6592e3e10c90e4fb35"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Emulex 10/20GbE Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE Emulex 10/20GbEドライバー for Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0728","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c220a","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c21d4","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072815908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul style=\"list-style-type:square\">\n\t<li>This product now supports Red Hat Enterprise Linux 8 Update 2 and&nbsp;Red Hat Enterprise Linux 8 Update 3</li>\n\t<li>This product now supports elx_net_install.sh installation script to install be2net driver on Red Hat Enterprise Linux 8 Update 1 or later.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"kmod-be2net","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2net","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2net","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2net","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWRTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLPeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757525443","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB008000GWRTC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB008000GWRTC Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"6007464","datemodified":"2021-07-23T07:32:39","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-5.1/CP048133.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-5.1/HVLPeAaseFG1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048133.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048133.scexe"],"md5sum":"7ba59349f05697deeaba36b4bbb919b0","name":"firmware-hdd-82894b9e0a-HPG1-5.1.x86_64.rpm","release":"2021-07-23T07:18:06","revision":"0","sha1sum":"08bc553b5aacf197b769845161e004d51aacdacc","size":"5MB","target_guids":["4d2340a5-3042-3830-3030-304757525443"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"d7cf155e76584b1f8fb8e3c7c222c90d","version":"ed16ae0c0cf24cfd9bdf3a9695fdfdb7"},"installation":{"command":"CP041482.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB008000GWRTC Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB008000GWRTC ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB008000GWRTC","target_guid":"4d2340a5-3042-3830-3030-304757525443","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-26T11:44:13","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000GWRTC","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWUDB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEBHssseFD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57554442","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB014000JWUDB"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB014000JWUDB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB014000JWUDB Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp; </strong>None</p>\n"}],"files":[{"bytes":"18890758","datemodified":"2021-08-26T15:05:09","file_list":["/CP048341_BUILD_2.data","/CP048341.vmexe","/CP048341.vmexe64","/CP048341.vmfile","/CP048341_VMw.zip","/CP048341.xml","/payload.json","/CP048341_VMw.zip/index.xml","/CP048341_VMw.zip/vendor-index.xml","/CP048341_VMw.zip/metadata.zip","/CP048341_VMw.zip/vib20/CP048341/HPE_bootbank_CP048341_HPD3.2-7.0.0.15843807.vib","/CP048341_VMw.zip/metadata.zip/vendor-index.xml","/CP048341_VMw.zip/metadata.zip/vmware.xml","/CP048341_VMw.zip/metadata.zip/vibs/CP048341--6959645046417752885.xml","/CP048341_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048341_HPD3.2-7.0.0.15843807.xml"],"md5sum":"afb2bacfe5de226f2041ad69299d2543","name":"CP048341.zip","release":"2021-08-26T14:59:46","revision":"0","sha1sum":"0e1a9b46b2aa384f22d00cb65f9080310bc2c05b","size":"18MB","target_guids":["4d2340a5-3042-3431-3030-304a57554442"],"type_of_change":"1","version":"HPD3","vib_list":[{"name":"CP048341","version":"HPD3.2-7.0.0.15843807"}]}],"id":{"product":"a2bc84f793fd4972b6196baf3df85eb6","version":"198e704d96c8412d89b554415230b878"},"installation":{"command":"CP041510.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB014000JWUDB Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB014000JWUDB ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB014000JWUDB","target_guid":"4d2340a5-3042-3431-3030-304a57554442","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-06T14:29:36","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to &ldquo;HPE&rdquo;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB014000JWUDB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWCBC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRN620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757434243","Version":"HPG6"},{"DeviceName":"MB002000GWCBD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRN620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757434244","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB001000GWCBC and MB002000GWCBD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64)-&nbsp;&nbsp;MB001000GWCBC and MB002000GWCBD Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG4</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG4<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5891226","datemodified":"2021-07-23T08:03:26","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-68b12e54d2-HPG6-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-68b12e54d2-HPG6-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-68b12e54d2-HPG6-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-68b12e54d2-HPG6-6.1/CP048093.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-68b12e54d2-HPG6-6.1/WRN620G6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-68b12e54d2-HPG6-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-68b12e54d2-HPG6-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-68b12e54d2-HPG6-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-68b12e54d2-HPG6-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048093.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048093.scexe"],"md5sum":"464ef5a99d8c590b159bcf06dd22709f","name":"firmware-hdd-68b12e54d2-HPG6-6.1.x86_64.rpm","release":"2021-07-23T07:49:09","revision":"0","sha1sum":"8da7ebad42f49d3ac26b2ecd3f77c52c988db828","size":"5MB","target_guids":["4d2340a5-3042-3130-3030-304757434243","4d2340a5-3042-3230-3030-304757434244"],"type_of_change":"1","version":"HPG6"}],"id":{"product":"c41c6d23d08b454ca2ee1c24f966683f","version":"ae965177a92e4f78ae75c731dae78408"},"installation":{"command":"CP040777.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB001000GWCBC and MB002000GWCBD Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB001000GWCBCおよびMB002000GWCBDドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB001000GWCBC","target_guid":"4d2340a5-3042-3130-3030-304757434243","type":"sata"},{"id":"MB002000GWCBD","target_guid":"4d2340a5-3042-3230-3030-304757434244","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T12:10:33","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB001000GWCBC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB002000GWCBD","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware for Converged Network and Network only adapters. \n\n"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"7608032","datemodified":"2021-08-27T07:22:17","file_list":["brcmflashStandalone-windows-12.0.1336.0-1/firmware/","brcmflashStandalone-windows-12.0.1336.0-1/firmware/oc14-12.0.1336.0.ufi","brcmflashStandalone-windows-12.0.1336.0-1/win/","brcmflashStandalone-windows-12.0.1336.0-1/win/brcmflash.bat","brcmflashStandalone-windows-12.0.1336.0-1/win/brcmwinlpcfg.bat","brcmflashStandalone-windows-12.0.1336.0-1/win/x64/","brcmflashStandalone-windows-12.0.1336.0-1/win/x64/brcmflash.exe","brcmflashStandalone-windows-12.0.1336.0-1/win/x64/BrcmMILI.dll","brcmflashStandalone-windows-12.0.1336.0-1/win/x64/brcmwinlpcfg.exe","brcmflashStandalone-windows-12.0.1336.0-1/win/x64/firmware/","brcmflashStandalone-windows-12.0.1336.0-1/win/x64/libbrcmdfc.dll","brcmflashStandalone-windows-12.0.1336.0-1/win/x64/RM.INI","cp049111.xml","cpqsetup.exe","fwmatrix.txt","brcmflashStandalone-windows-12.0.1336.0-1/win/x64/fwmatrix.txt","hpe_fw_matrix.xml","installer.dll","payload.json","readme.txt","brcmflashStandalone-windows-12.0.1336.0-1/win/x64/readme.txt","reference.xml"],"md5sum":"ea6d5e2bda3b1d7106abf1d676c5ccaa","name":"cp049111.exe","release":"2021-08-27T07:06:42","revision":"0","sha1sum":"0ffd3afb266c528ed200477f212fc80df6d9798b","size":"7MB","target_guids":[],"type_of_change":"1","version":"2021.10.01"}],"id":{"product":"b985ec116eb7489c9dc44114903f5d6d","version":"276612703c1e445db53a66241946e5ee"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p dir=\"LTR\">Download the Smart Component to a directory on your hard drive and change to that directory.</p>\n\n<p>The downloaded file is a self-extracting executable with a filename based on the Component Number.<br />\nFrom that drive and directory, execute the downloaded file.<br />\n<br />\nClick the &quot;Install&quot; button to proceed with the installation.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Converged Network Adapters for Microsoft Windows Server 2012R2(x64)"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"0724","subdev":"21D4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"21D4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"8153","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8153","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8144","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"8144","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"220A","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"220A","subven":"103C","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-23T08:45:22","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p dir=\"LTR\">Updated CNA (XE100 series) firmware</p>\n\n<p>&nbsp;</p>\n\n<p>This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot BIOS</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 10Gb 2-port 556FLR-T Adapter</td>\n\t\t\t<td>10Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</td>\n\t\t\t<td>10Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE CN1200E Dual Port Converged Network Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE&nbsp;CN1200E-T Dual Port Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"}],"sw_keys":[{"name":"emulex_cna","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWJRQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a574a5251","Version":"HPD9"},{"DeviceName":"MB006000JWJRP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574a5250","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB008000JWJRQ and MB006000JWJRP"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online HDD/SSD&nbsp;Flash Component for VMware ESXi - MB008000JWJRQ_MB006000JWJRP&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>This firmware release provides additional protection against command timeouts.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16237838","datemodified":"2021-08-26T10:27:04","file_list":["/CP049132_BUILD_2.data","/CP049132.vmexe","/CP049132.vmexe64","/CP049132.vmfile","/CP049132_VMw.zip","/CP049132.xml","/payload.json","/CP049132_VMw.zip/index.xml","/CP049132_VMw.zip/vendor-index.xml","/CP049132_VMw.zip/metadata.zip","/CP049132_VMw.zip/vib20/CP049132/HPE_bootbank_CP049132_HPD9.2-7.0.0.15843807.vib","/CP049132_VMw.zip/metadata.zip/vendor-index.xml","/CP049132_VMw.zip/metadata.zip/vmware.xml","/CP049132_VMw.zip/metadata.zip/vibs/CP049132--7449206712739965198.xml","/CP049132_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049132_HPD9.2-7.0.0.15843807.xml"],"md5sum":"bc2c1a049d890b1013a9e4a075d27a1d","name":"CP049132.zip","release":"2021-08-26T10:21:34","revision":"0","sha1sum":"c1297cc0e4e44a952d6eec995c71c1b17f092ca5","size":"15MB","target_guids":["4d2340a5-3042-3830-3030-304a574a5251","4d2340a5-3042-3630-3030-304a574a5250"],"type_of_change":"1","version":"HPD9","vib_list":[{"name":"CP049132","version":"HPD9.2-7.0.0.15843807"}]}],"id":{"product":"5e76fbf672b8432aa6436d748dacb463","version":"e5bd62e42eb14a1bba321303c671f55c"},"installation":{"command":"CP041025.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします。</li>\n\t<li>CPXXXXXX.vmexe(ESXi 6.7 &以前のバージョン)およびCPXXXXXX.vmexe64(ESXi 7.0)は、次のコマンドを使用して実行可能です:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod x CPXXXXXX.vmexe    または    chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPXXXXXX.vmexe(または)./CPXXXXXX.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB008000JWJRQ and MB006000JWJRP  Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB008000JWJRQおよび MB006000JWJRP ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB008000JWJRQ","target_guid":"4d2340a5-3042-3830-3030-304a574a5251","type":"sas"},{"id":"MB006000JWJRP","target_guid":"4d2340a5-3042-3630-3030-304a574a5250","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T17:02:33","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This firmware release provides additional protection against command timeouts.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This firmware release provides additional protection against command timeouts.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000JWJRQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB006000JWJRP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"tw","x_late":"為 iLO 提供 OS 層級無代理程式管理資訊與使用中狀況系統 (Active Health System) 事件。"},{"lang":"en","x_late":"Provides iLO with OS-level Agentless Management information and Active Health System events."},{"lang":"ko","x_late":"iLO에 OS 레벨 Agentless 관리 정보 및 Active Health System 이벤트를 제공합니다."},{"lang":"cn","x_late":"向 iLO 提供操作系统级无代理管理信息和活动健康系统事件。"},{"lang":"ja","x_late":"iLOにOSレベルのエージェントレスマネジメントの情報およびアクティブヘルスシステムイベントを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[{"lang":"en","x_late":"<ul>\n\t<li>IML events marked as repaired in ILO will not be mirrored in Windows Event Log.</li>\n\t<li>If Windows Server 2016 Device Guard policy is enabled, AMS can be upgraded from an older version to a newer version,&nbsp; but it cannot be uninstalled.&nbsp; To uninstall AMS, the Device Guard policy needs to be temporarily disabled.</li>\n\t<li>The controller&nbsp;HP StorageWorks 81B 8Gb Single Port PCI-e FC HBA will be shown as&nbsp;QLogic BR-415/815 4G/8G FC HBA.</li>\n</ul>\n"},{"lang":"ja","x_late":"<ul>\n\t<li>iLOで修復済みとマークされたIMLイベントは、Windowsイベントログでは反映されません。</li>\n\t<li>Windows Server 2016 Device Guardポリシーが有効になっている場合は、AMSを古いバージョンから新しいバージョンにアップグレードできますが、AMSをアンインストールすることはできません。  AMSをアンインストールするには、Device Guardポリシーを一時的に無効にする必要があります。</li>\n\t<li>コントローラーHP StorageWorks 81B 8Gb シングルポートPCI-e FC HBAは QLogic BR-415/815 4G/8G FC HBAと表示されます。</li>\n</ul>\n"}],"files":[{"bytes":"8509472","datemodified":"2021-07-15T10:08:00","file_list":["cp047524.xml","cpqsetup.exe","hpqams.cab","hpqams.msi","install.xml","MergeModule2012.msi","multisetup.dll"],"md5sum":"349657cbc6ff70e3d613ba73a83854ba","name":"cp047524.exe","release":"2021-07-15T10:05:10","revision":"0","sha1sum":"ed34e9c55d19ecb6113134638d51c2af2785f31a","size":"8MB","target_guids":[],"type_of_change":"0","version":"10.100.0.0"}],"id":{"product":"634c75df063f418e8a220d306623aa90","version":"b03a5cc2456a41148a3e374264ec2e7a"},"installation":{"command":"cpqsetup.exe","command_params":"/verbose_log","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 3/4 Channel Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 3/4 Channel Interface Driver for Windows"}]}]}]},"installation_notes":[{"lang":"tw","x_late":"<P>將智慧型元件放在臨時目錄中，按兩下執行。</P>\n<P>選擇「Install (安裝)」開始解壓縮至硬碟上的一個臨時位置。</P>\n<P>按一下「Install (安裝)」繼續進行驅動程式的安裝。</P>"},{"lang":"en","x_late":"<P>Place the Smart Component in a temporary directory, then double-click it to run.</P>\n<P>Select \"Install\" to start extracting to a temporary location on the hard drive.</P>\n<P>Click the \"Install\" button to perform the service installation.</P>"},{"lang":"ko","x_late":"<P>스마트 구성 요소를 임시 디렉터리에 저장하고 이를 더블 클릭하여 실행합니다.</P>\n<P>\"설치\"를 선택하여 하드 드라이브의 임시 디렉터리에 압축을 풉니다.</P>\n<P>\"설치\" 버튼을 클릭하여 서비스 설치 작업을 시작합니다.</P>"},{"lang":"cn","x_late":"<P>将智能组件置于临时目录中，然后双击运行。</P>\n<P>选择“安装”，开始提取至硬盘的临时位置。</P>\n<P>点击“安装”按钮执行服务安装。</P>"},{"lang":"ja","x_late":"<P>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。</P>\n<P>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。</P>\n<P>[インストール]ボタンをクリックしてサービスインストールを実行します。</P>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE ProLiant Agentless Management Service for HPE Apollo, ProLiant and Synergy Gen9 servers"},{"lang":"ja","x_late":"HPE Apollo、ProLiantおよびSynergy Gen9サーバーのHPE ProLiant Agentless Managementサービス"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-13T06:15:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added Logical Drive Trap&nbsp;5023.</li>\n\t<li>Changed IDE/SATA interval time from 120 seconds to 60 seconds.</li>\n\t<li>Redirect more iLO security logs to the Windows event system.</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Fixed IML missing NIC link down record if the user unplugs many cables at the same time.</li>\n\t<li>Fixed iLO web GUI missing IPv6 address when Windows Hype-V switch is created.</li>\n\t<li>Fixed a crash issue when AMS is querying iSCSI information.</li>\n\t<li>Fixed incorrect drive status if IDE SATA drive is busy on access.</li>\n\t<li>Fixed incorrect drive status if Windows see&nbsp;the predictive failure drive.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>None</p>\n","curr_fixes_x_late":"<p>Fix issues.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"}],"sw_keys":[{"name":"hpqams.exe","sw_key_expectedpath":"%ProgramFiles%\\Hewlett-Packard\\AMS\\service"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000JFEML","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a46454d4c","Version":"HPD6"},{"DeviceName":"MB4000JFEMN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a46454d4e","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB2000JFEML and MB4000JFEMN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB2000JFEML and MB4000JFEMN Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.&nbsp; This issue was found during supplier ongoing reliability testing.</p>\n\t</li>\n\t<li>\n\t<p>The firmware also includes emergency power off improvements.</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"3625856","datemodified":"2021-07-25T14:20:05","file_list":["cp048590.xml","cpqsetup.exe","HAKPNSD6.rel","payload.json","setup.dll"],"md5sum":"6a646078709a2e476cf4e04b67ae0e15","name":"cp048590.exe","release":"2021-07-25T14:13:05","revision":"0","sha1sum":"0500c2eba0c4df5011191314f60af3ec473058e0","size":"3MB","target_guids":["002340a5-4d00-3242-3030-304a46454d4c","002340a5-4d00-3442-3030-304a46454d4e"],"type_of_change":"2","version":"HPD6"}],"id":{"product":"43e2b01e979548ad962efb95de5a6d12","version":"eac7f4dc955b411682f2eae4b268c1da"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB2000JFEML and MB4000JFEMN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB2000JFEMLおよびMB4000JFEMNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB2000JFEML","target_guid":"002340a5-4d00-3242-3030-304a46454d4c","type":"sas"},{"id":"MB4000JFEMN","target_guid":"002340a5-4d00-3442-3030-304a46454d4e","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T09:57:05","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was found during supplier ongoing reliability testing.</li>\n\t<li>The firmware also includes emergency power off improvements.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was found during supplier ongoing reliability testing.</li>\n\t<li>The firmware also includes emergency power off improvements.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JFEMN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB2000JFEML","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GEQUT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHc8HaoeFGB.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745515554","Version":"HPGB"},{"DeviceName":"MB8000GEQUU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHc8HaoeFGB.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3842-3030-304745515555","Version":"HPGB"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SATA drive models: MB6000GEQUT and MB8000GEQUU"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。 MB6000GEQUTおよびMB8000GEQUU"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB6000GEQUT and MB8000GEQUU Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGB<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPGA</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.&nbsp; This issue was only found during supplier ongoing reliability testing.</li>\n\t<li>Fixed the issue of Online firmware update fails when drives are connected behind AHCI controller.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5584068","datemodified":"2021-07-23T07:34:56","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-1d7f19120b-HPGB-9.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-1d7f19120b-HPGB-9.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-1d7f19120b-HPGB-9.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-1d7f19120b-HPGB-9.1/CP048167.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-1d7f19120b-HPGB-9.1/HAHc8HaoeFGB.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-1d7f19120b-HPGB-9.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-1d7f19120b-HPGB-9.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-1d7f19120b-HPGB-9.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-1d7f19120b-HPGB-9.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048167.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048167.scexe"],"md5sum":"f73d8fabe5ddafcaf46fc56dc84e925d","name":"firmware-hdd-1d7f19120b-HPGB-9.1.x86_64.rpm","release":"2021-07-23T07:22:11","revision":"0","sha1sum":"f9221262d64842a5a6aa3f8615696412291f2166","size":"5MB","target_guids":["002340a5-4d00-3642-3030-304745515554","002340a5-4d00-3842-3030-304745515555"],"type_of_change":"2","version":"HPGB"}],"id":{"product":"f588f22bf7a8476e978b8ff370066200","version":"dc048560551b44d082dd64fa780e9834"},"installation":{"command":"CP040322.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB6000GEQUT and MB8000GEQUU Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB6000GEQUTおよびMB8000GEQUUドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB6000GEQUT","target_guid":"002340a5-4d00-3642-3030-304745515554","type":"sata"},{"id":"MB8000GEQUU","target_guid":"002340a5-4d00-3842-3030-304745515555","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T19:38:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was only found during supplier ongoing reliability testing.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was only found during supplier ongoing reliability testing.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB8000GEQUU","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB6000GEQUT","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built for SUSE Linux Enterprise Server 12 (64-bit) to enable the HPE Smart Array B140i SATA RAID controller."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"985025","datemodified":"2021-05-28T07:51:54","file_list":["./etc/dracut.conf.d/hpdsa.conf","./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/hpdsa.ko","./usr/share/smartupdate/hpdsa-kmp-default/component.xml"],"md5sum":"417b142aa58b90204b55416b7d699895","name":"hpdsa-kmp-default-1.2.10-196.sles12sp4.x86_64.rpm","release":"2021-05-28T07:41:09","revision":"0","sha1sum":"e414d1877455ed173691c71e1be57141894e34db","size":"961KB","target_guids":[],"type_of_change":"1","version":"1.2.10-196"},{"bytes":"980830","datemodified":"2021-05-28T07:57:52","file_list":["./etc/dracut.conf.d/hpdsa.conf","./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/hpdsa.ko","./usr/share/smartupdate/hpdsa-kmp-default/component.xml"],"md5sum":"eac2e80e247ca560820233eb94312777","name":"hpdsa-kmp-default-1.2.10-196.sles12sp5.x86_64.rpm","release":"2021-05-28T07:41:09","revision":"0","sha1sum":"b6602f8c3de53aa67821407c6ef4e4f19407a03a","size":"957KB","target_guids":[],"type_of_change":"1","version":"1.2.10-196"}],"id":{"product":"5087e00798b842dd96c4ffa314df5670","version":"d95c265f44944db99be21c941c2a440b"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as the system administrator (root), download the RPM to a directory on<br />\nyour hard drive and change to that directory.</p>\n\n<p dir=\"ltr\"><strong>To install&nbsp;or&nbsp;upgrade&nbsp;the driver type:</strong></p>\n\n<p># rpm -Uvh hpdsa-kmp-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</p>\n\n<p>Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p dir=\"ltr\">NOTE: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:</p>\n\n<p dir=\"ltr\"># rpm -e hpdsa-kmp-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</p>\n\n<p dir=\"ltr\"><strong><u>Enterprise Support</u></strong><br />\nFor support on Smart Array controllers, visit&nbsp;<a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a></p>\n"},{"lang":"ja","x_late":"<p>システム管理者（root）としてログインし、RPMを<br />\nご使用のハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</p>\n\n<p dir=\"ltr\"><strong>ドライバーをインストールまたはアップグレードするには次のようにタイプします。</strong></p>\n\n<p># rpm -Uvh hpdsa-kmp-<version>.<OSupdate>.x86_64.rpm</p>\n\n<p>Setup is now complete. コンピューターをただちに再起動してください。</p>\n\n<p dir=\"ltr\">注記：インストールの失敗、あるいは警告やエラーメッセージを表示して停止した場合は、コンピューターを再起動しないでください。ドライバーは動作しないため、以下のコマンドをタイプしてアンインストールしてください。</p>\n\n<p dir=\"ltr\"># rpm -e hpdsa-kmp-<version>.<OSupdate>.x86_64.rpm</p>\n\n<p dir=\"ltr\"><strong><u>エンタープライズサポート</u></strong><br />\nSmartアレイコントローラーのサポートに関しては、<a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a>を参照してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Dynamic Smart Array B140i SATA RAID Controller Driver for SUSE LINUX Enterprise Server 12 (64-bit)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"8D06","subdev":"009C","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"8D66","subdev":"009D","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"A106","subdev":"00C0","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"A107","subdev":"00C0","subven":"1590","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T07:08:34","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Add support for SuSE Linux Enterprise Server 12 SP5</p>\n","latest_fixes_x_late":"<ul>\n\t<li>Added PKCS signing process to fix the secure boot hang issue on Linux SLES12 SP5.</li>\n\t<li>Fix SATL error handling of AHCI reported Fatal errors with NCQ and Non-NCQ commands potentially causing RAID stack timeouts and excessive read/write command timeouts leading to SCSI bus reset with M.2 SSD drives configured with SW RAID.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Intial Version</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U25","value":"HP ProLiant XL280d Accelerator Tray - cancelled"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"hpdsa-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hpdsa-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hpdsa-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hpdsa-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWCPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTED9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57435048","Version":"HPD9"},{"DeviceName":"EH000600JWCPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTED9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57435046","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EH000600JWCPF and EH000900JWCPH"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EH000600JWCPFおよびEH000900JWCPH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;EH000600JWCPF and EH000900JWCPH Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"17939226","datemodified":"2021-08-30T06:15:16","file_list":["/CP048272_BUILD_2.data","/CP048272.vmexe","/CP048272.vmexe64","/CP048272.vmfile","/CP048272_VMw.zip","/CP048272.xml","/payload.json","/CP048272_VMw.zip/index.xml","/CP048272_VMw.zip/vendor-index.xml","/CP048272_VMw.zip/metadata.zip","/CP048272_VMw.zip/vib20/CP048272/HPE_bootbank_CP048272_HPD9.2-7.0.0.15843807.vib","/CP048272_VMw.zip/metadata.zip/vendor-index.xml","/CP048272_VMw.zip/metadata.zip/vmware.xml","/CP048272_VMw.zip/metadata.zip/vibs/CP048272-698966563930879478.xml","/CP048272_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048272_HPD9.2-7.0.0.15843807.xml"],"md5sum":"453a38a06578230a6abe3a8f6a741ec9","name":"CP048272.zip","release":"2021-08-30T06:09:00","revision":"0","sha1sum":"2dd336c5fb32430581638538edb5c460313bf62e","size":"17MB","target_guids":["452340a5-3048-3030-3930-304a57435048","452340a5-3048-3030-3630-304a57435046"],"type_of_change":"1","version":"HPD9","vib_list":[{"name":"CP048272","version":"HPD9.2-7.0.0.15843807"}]}],"id":{"product":"ec5fd859b967489ab6f67ad677712984","version":"01e1af1d79f742f8b211eaccc0316d90"},"installation":{"command":"CP040536.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン：</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例：./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります:rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EH000600JWCPF and EH000900JWCPH Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - EH000600JWCPFおよびEH000900JWCPHドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EH000600JWCPF","target_guid":"452340a5-3048-3030-3630-304a57435046","type":"sas"},{"id":"EH000900JWCPH","target_guid":"452340a5-3048-3030-3930-304a57435048","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-02T17:46:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH000900JWCPH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000600JWCPF","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000800KWWFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3830-304b57574645","Version":"HPK3"},{"DeviceName":"MK001600KWWFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3630-304b57574646","Version":"HPK3"},{"DeviceName":"MK003200KWWFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3230-304b57574648","Version":"HPK3"},{"DeviceName":"MK006400KWWFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3630-3430-304b5757464b","Version":"HPK3"},{"DeviceName":"VK000960KWWFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304b5757464c","Version":"HPK3"},{"DeviceName":"VK001920KWWFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304b5757464e","Version":"HPK3"},{"DeviceName":"VK003840KWWFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304b57574650","Version":"HPK3"},{"DeviceName":"VK007680KWWFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-304b57574651","Version":"HPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online NVMe SSD Flash Component for Linux (x64) - &nbsp;MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>This FW change resolves a MCTP VDM compliance issue seen by iLO version 2.30.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111061en_us</li>\n</ul>\n\n<p>&nbsp;<strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"7064464","datemodified":"2021-09-21T08:06:50","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK3-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK3-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK3-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK3-6.1/CP048229.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK3-6.1/KPE60X1GHPK3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK3-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK3-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK3-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK3-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048229.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048229.scexe"],"md5sum":"65c7d017954ac9493f98725b0269aef6","name":"firmware-hdd-54addf5312-HPK3-6.1.x86_64.rpm","release":"2021-09-21T07:51:10","revision":"0","sha1sum":"715705882789b83e49557e8bac244abf53d7fb49","size":"6MB","target_guids":["4d2340a5-304b-3030-3830-304b57574645","4d2340a5-304b-3130-3630-304b57574646","4d2340a5-304b-3330-3230-304b57574648","4d2340a5-304b-3630-3430-304b5757464b","562340a5-304b-3030-3936-304b5757464c","562340a5-304b-3130-3932-304b5757464e","562340a5-304b-3330-3834-304b57574650","562340a5-304b-3730-3638-304b57574651"],"type_of_change":"2","version":"HPK3"}],"id":{"product":"3d004333c656491289fdf09d5881fcdd","version":"0cc49d0183f943c7b2a9f8ec056ad56c"},"installation":{"command":"CP041698.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left: 30pt;\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>rpmのインストールによりファームウェアをアップデート:</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするには、以下のコマンドの<strong>1つ</strong>を実行します:\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left: 30pt;\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するには Service Pack for ProLiant から以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux（x64）- MK000800KWWFE、MK001600KWWFF、MK003200KWWFH、MK006400KWWFK、VK000960KWWFL、VK001920KWWFN、VK003840KWWFP、およびVK007680KWWFQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VK007680KWWFQ","target_guid":"562340a5-304b-3730-3638-304b57574651","type":"nvme"},{"id":"MK006400KWWFK","target_guid":"4d2340a5-304b-3630-3430-304b5757464b","type":"nvme"},{"id":"VK003840KWWFP","target_guid":"562340a5-304b-3330-3834-304b57574650","type":"nvme"},{"id":"MK003200KWWFH","target_guid":"4d2340a5-304b-3330-3230-304b57574648","type":"nvme"},{"id":"VK001920KWWFN","target_guid":"562340a5-304b-3130-3932-304b5757464e","type":"nvme"},{"id":"MK001600KWWFF","target_guid":"4d2340a5-304b-3130-3630-304b57574646","type":"nvme"},{"id":"VK000960KWWFL","target_guid":"562340a5-304b-3030-3936-304b5757464c","type":"nvme"},{"id":"MK00800KWWFE","target_guid":"002340a5-4b4d-3030-3830-304b57574645","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-01T04:48:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This FW change resolves a MCTP VDM compliance issue seen by iLO version 2.30.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111061en_us</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This FW change resolves a MCTP VDM compliance issue seen by iLO version 2.30.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111061en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK003840KWWFP","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK001600KWWFF","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK000800KWWFE","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK003200KWWFH","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK007680KWWFQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK001920KWWFN","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK000960KWWFL","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK006400KWWFK","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO0800JEFPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304f-3830-304a45465046","Version":"HPD3"},{"DeviceName":"EO0400JEFPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304f-3430-304a45465045","Version":"HPD3"},{"DeviceName":"EO0200JEFPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304f-3230-304a45465044","Version":"HPD3"},{"DeviceName":"MO1600JEFPC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304a45465043","Version":"HPD3"},{"DeviceName":"MO0800JEFPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3830-304a45465042","Version":"HPD3"},{"DeviceName":"MO0400JEFPA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3430-304a45465041","Version":"HPD3"},{"DeviceName":"MO0200JEFNV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3230-304a45464e56","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MO0200JEFNV, MO0400JEFPA, MO0800JEFPB, MO1600JEFPC, EO0200JEFPD, EO0400JEFPE and EO0800JEFPF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for&nbsp;VMware ESXi&nbsp;- MO0200JEFNV, MO0400JEFPA, MO0800JEFPB, MO1600JEFPC, EO0200JEFPD, EO0400JEFPE&nbsp;and EO0800JEFPF Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong>&nbsp;&nbsp;&nbsp;&nbsp;<br />\n&nbsp; &nbsp; &nbsp; None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"16874323","datemodified":"2021-08-27T07:33:26","file_list":["/CP048401_BUILD_3.data","/CP048401.vmexe","/CP048401.vmexe64","/CP048401.vmfile","/CP048401_VMw.zip","/CP048401.xml","/payload.json","/CP048401_VMw.zip/index.xml","/CP048401_VMw.zip/vendor-index.xml","/CP048401_VMw.zip/metadata.zip","/CP048401_VMw.zip/vib20/CP048401/HPE_bootbank_CP048401_HPD3.3-7.0.0.15843807.vib","/CP048401_VMw.zip/metadata.zip/vendor-index.xml","/CP048401_VMw.zip/metadata.zip/vmware.xml","/CP048401_VMw.zip/metadata.zip/vibs/CP048401--5580745014109652053.xml","/CP048401_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048401_HPD3.3-7.0.0.15843807.xml"],"md5sum":"dd3ffed120370b5e791aa09d4fe2b36c","name":"CP048401.zip","release":"2021-08-27T07:28:00","revision":"0","sha1sum":"3a73dd1235bfe5ef218e3fc213e6754d6053c8b4","size":"16MB","target_guids":["002340a5-4500-304f-3830-304a45465046","002340a5-4500-304f-3430-304a45465045","002340a5-4500-304f-3230-304a45465044","002340a5-4d00-314f-3630-304a45465043","002340a5-4d00-304f-3830-304a45465042","002340a5-4d00-304f-3430-304a45465041","002340a5-4d00-304f-3230-304a45464e56"],"type_of_change":"1","version":"HPD3","vib_list":[{"name":"CP048401","version":"HPD3.3-7.0.0.15843807"}]}],"id":{"product":"22bf9e4ced19410ca8b8850245112a89","version":"17921eb24c6f42faa96f6d5e01004f4c"},"installation":{"command":"CP039420.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MO0200JEFNV, MO0400JEFPA, MO0800JEFPB, MO1600JEFPC, EO0200JEFPD, EO0400JEFPE and EO0800JEFPF Drives"},{"lang":"ja","x_late":"オンラインHDD/SDDフラッシュコンポーネント for VMware ESXi - MO0200JEFNV、MO0400JEFPA、MO0800JEFPB、MO1600JEFPC、EO0200JEFPD、EO0400JEFPE、およびEO0800JEFPFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EO0800JEFPF","target_guid":"002340a5-4500-304f-3830-304a45465046","type":"sas"},{"id":"MO1600JEFPC","target_guid":"002340a5-4d00-314f-3630-304a45465043","type":"sas"},{"id":"EO0200JEFPD","target_guid":"002340a5-4500-304f-3230-304a45465044","type":"sas"},{"id":"MO0200JEFNV","target_guid":"002340a5-4d00-304f-3230-304a45464e56","type":"sas"},{"id":"EO0400JEFPE","target_guid":"002340a5-4500-304f-3430-304a45465045","type":"sas"},{"id":"MO0400JEFPA","target_guid":"002340a5-4d00-304f-3430-304a45465041","type":"sas"},{"id":"MO0800JEFPB","target_guid":"002340a5-4d00-304f-3830-304a45465042","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T19:08:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EO0200JEFPD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO0400JEFPE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO0800JEFPF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO0200JEFNV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO1600JEFPC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO0800JEFPB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO0400JEFPA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWWQH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757575148","Version":"HPG3"},{"DeviceName":"MB002000GWWQF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757575146","Version":"HPG3"},{"DeviceName":"MB001000GWWQE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757575145","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB004000GWWQH、MB002000GWWQF、およびMB001000GWWQEドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG2</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG2<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5505396","datemodified":"2021-07-23T09:22:30","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG3-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG3-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG3-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG3-3.1/CP048203.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG3-3.1/SCIMARRNNTG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG3-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG3-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG3-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG3-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048203.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048203.scexe"],"md5sum":"592e3e6c9a31d1c868f6310290911eaa","name":"firmware-hdd-12304c1aca-HPG3-3.1.x86_64.rpm","release":"2021-07-23T09:09:10","revision":"0","sha1sum":"f9affa138ccbed9e8b24f83e5b2ab07578a08f26","size":"5MB","target_guids":["4d2340a5-3042-3430-3030-304757575148","4d2340a5-3042-3230-3030-304757575146","4d2340a5-3042-3130-3030-304757575145"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"205e86b4ae1e4a28ae1e3cf39faf17ba","version":"26220bd464044731946a4aa2a8156cfc"},"installation":{"command":"CP043255.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート:</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするには、以下のコマンドの<strong>1つ</strong>を実行します:\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>（.rpm拡張子の付いていないrpmファイル名）を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するには Service Pack for ProLiant から以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for Linux (x64) - MB004000GWWQH、MB002000GWWQF、およびMB001000GWWQEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB004000GWWQH","target_guid":"4d2340a5-3042-3430-3030-304757575148","type":"sata"},{"id":"MB002000GWWQF","target_guid":"4d2340a5-3042-3230-3030-304757575146","type":"sata"},{"id":"MB001000GWWQE","target_guid":"4d2340a5-3042-3130-3030-304757575145","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T11:23:37","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB001000GWWQE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB002000GWWQF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB004000GWWQH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900083","languages":[{"lang":"tw","x_late":"韌體 ─ 電源管理"},{"lang":"en","x_late":"Firmware - Power Management"},{"lang":"ko","x_late":"펌웨어 - 전원 관리"},{"lang":"ja","x_late":"ファームウェア - パワー マネジメント"},{"lang":"cn","x_late":"固件 - 电源管理"}]}],"description":[{"lang":"en","x_late":"This component updates the  Advanced Power Capping Microcontroller Firmware for HPE Gen9 Servers"},{"lang":"ja","x_late":"このコンポーネントは、アドバンスト消費電力上限マイクロコントローラーファームウェア for HPE Gen9サーバーをアップデートします"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"415099","datemodified":"2019-01-14T15:31:52","file_list":["./usr/lib/i386-linux-gnu/firmware-powerpic-gen9-1.0.9-10.1","./usr/lib/i386-linux-gnu/firmware-powerpic-gen9-1.0.9-10.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-powerpic-gen9-1.0.9-10.1/.hpsetup","./usr/lib/i386-linux-gnu/firmware-powerpic-gen9-1.0.9-10.1/CP038726.xml","./usr/lib/i386-linux-gnu/firmware-powerpic-gen9-1.0.9-10.1/PICGen9_1.0.9s.hex","./usr/lib/i386-linux-gnu/firmware-powerpic-gen9-1.0.9-10.1/hpsetup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP038726.scexe"],"md5sum":"725937308ebabeb8f14a9854449459f8","name":"firmware-powerpic-gen9-1.0.9-10.1.i386.rpm","release":"2019-01-31T00:00:00","revision":"1","sha1sum":"883dc311069904fb12c53b1bfdc3680860427ee8","size":"405KB","target_guids":[],"type_of_change":"0","version":"1.0.9"}],"id":{"product":"b7238ec8b07746d28a0d044f81b28100","version":"fbe0f034e17d46b591b978c2e2152021"},"installation":{"command":"cpqsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HPE ProLiant Agentless Management Service (ams) and HPE SNMP Agents (hp-snmp-agents) are both running.&nbsp; HPE does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>\n\t<p>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</p>\n\t</li>\n\t<li>\n\t<p>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key. To use with HPE SUM 7.6.0 or earlier, place the components in \\hp\\swpackages on the USB Key.</p>\n\n\t<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\t</li>\n</ul>\n\n<ul>\n</ul>\n"},{"lang":"ja","x_late":"<p>重要: このコンポーネントは、iLOとの通信ができない場合に失敗します。  これは、HPE ProLiant Agentless Management Service (AMS)およびHPE SNMPエージェント(SNMP Agents)の両方が実行されているときに発生します。  HPEでは、AMSおよびSNMPエージェントを同時に実行させないことを推奨します。  「iLO device not found」エラーが発生した場合、AMSまたはSNMPエージェントを停止させて、再度フラッシュコンポーネントを実行します。<br />\n<br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>\n\t<p>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</p>\n\t</li>\n\t<li>\n\t<p>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。HPE SUM 7.6.0またはそれ以前のバージョンを使用するには、\\hp\\swpackages内のコンポーネントをUSBキーにコピーしてください。</p>\n\n\t<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\t</li>\n</ul>\n\n<ul>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash for Linux - Advanced Power Capping Microcontroller Firmware for HPE Gen9 Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュ for Linux - アドバンスト消費電力上限マイクロコントローラーファームウェア for HPE Gen9サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Oracle Linux 7","platform":"Oracle Enterprise Linux","sr":"OEM"},{"major":"6","minor":"0","name":"Oracle Linux 6 (AMD64/EMT64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-02T05:54:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>Ver. 1.0.9(J) contains updates to the component packaging and is functionally equivalent to ver. 1.0.9. It is not necessary to upgrade with Revision J if a previous component Revision was used to upgrade the firmware to version 1.0.9.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>Addresses an issue in which the minimum power capping value was incorrectly being calculated on certain systems. This fix increases the accuracy of the minimum capping value set during POST.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>Ver. 1.0.9(J) contains updates to the component packaging and is functionally equivalent to ver. 1.0.9. It is not necessary to upgrade with Revision J if a previous component Revision was used to upgrade the firmware to version 1.0.9.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>Addresses an issue in which the minimum power capping value was incorrectly being calculated on certain systems. This fix increases the accuracy of the minimum capping value set during POST.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U19","value":"HPE ProLiant XL420 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"}],"sw_keys":[{"name":"PowerPIC-Gen9","sw_key_expectedpath":"firmware:sd:powerpic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000JFEPA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRAND5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a46455041","Version":"HPD5"},{"DeviceName":"MB4000JFEPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRAND5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a46455042","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB2000JFEPA and MB4000JFEPB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB2000JFEPA and MB4000JFEPB Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD2</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong>&nbsp;&nbsp;&nbsp;&nbsp;<br />\n&nbsp; &nbsp; &nbsp; None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"17435601","datemodified":"2021-08-26T19:28:27","file_list":["/CP048362_BUILD_2.data","/CP048362.vmexe","/CP048362.vmexe64","/CP048362.vmfile","/CP048362_VMw.zip","/CP048362.xml","/payload.json","/CP048362_VMw.zip/index.xml","/CP048362_VMw.zip/vendor-index.xml","/CP048362_VMw.zip/metadata.zip","/CP048362_VMw.zip/vib20/CP048362/HPE_bootbank_CP048362_HPD5.2-7.0.0.15843807.vib","/CP048362_VMw.zip/metadata.zip/vendor-index.xml","/CP048362_VMw.zip/metadata.zip/vmware.xml","/CP048362_VMw.zip/metadata.zip/vibs/CP048362--1361896709043931304.xml","/CP048362_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048362_HPD5.2-7.0.0.15843807.xml"],"md5sum":"c63fb1ed2f09ca5ac030158842b2c802","name":"CP048362.zip","release":"2021-08-26T19:23:29","revision":"0","sha1sum":"a067cf952ebf794818b1cb89cba54ecfa08c29bc","size":"16MB","target_guids":["002340a5-4d00-3242-3030-304a46455041","002340a5-4d00-3442-3030-304a46455042"],"type_of_change":"1","version":"HPD5","vib_list":[{"name":"CP048362","version":"HPD5.2-7.0.0.15843807"}]}],"id":{"product":"41fb5700b0aa44b2bbeca072e083be4b","version":"b4941fac9e7d4064b631fa965031dd1a"},"installation":{"command":"CP040514.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB2000JFEPA and MB4000JFEPB Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - MB2000JFEPAおよびMB4000JFEPBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB2000JFEPA","target_guid":"002340a5-4d00-3242-3030-304a46455041","type":"sas"},{"id":"MB4000JFEPB","target_guid":"002340a5-4d00-3442-3030-304a46455042","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-07T12:46:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JFEPB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB2000JFEPA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE QLogic NX2 10Gb and 20Gb Multifunction Gigabit Ethernet NICs running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 8で動作するHPE QLogic NX2 10Gbおよび20GbマルチファンクションGigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"9093017","datemodified":"2021-08-11T16:31:21","file_list":["./etc/depmod.d/netxtreme2.conf","./etc/dracut.conf.d/netxtreme2.conf","./lib/modules","./lib/modules/4.18.0-305.el8.x86_64","./lib/modules/4.18.0-305.el8.x86_64/extra","./lib/modules/4.18.0-305.el8.x86_64/extra/netxtreme2","./lib/modules/4.18.0-305.el8.x86_64/extra/netxtreme2/bnx2.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/netxtreme2/bnx2fc.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/netxtreme2/bnx2i.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/netxtreme2/bnx2x.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/netxtreme2/cnic.ko","./usr/share/smartupdate/kmod-netxtreme2/component.xml"],"md5sum":"9355240b4334e0b8a70dc68249d4b999","name":"kmod-netxtreme2-7.14.80-6.rhel8u4.x86_64.rpm","release":"2021-08-11T16:05:08","revision":"0","sha1sum":"281888634d50ac9bf18f2e8bc8105c4e403d1a34","size":"8MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec9fda3d1e"],"type_of_change":"0","version":"7.14.80-6"},{"bytes":"8936497","datemodified":"2021-08-11T16:28:30","file_list":["./etc/depmod.d/netxtreme2.conf","./etc/dracut.conf.d/netxtreme2.conf","./lib/modules","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/netxtreme2","./lib/modules/4.18.0-240.el8.x86_64/extra/netxtreme2/bnx2.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/netxtreme2/bnx2fc.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/netxtreme2/bnx2i.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/netxtreme2/bnx2x.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/netxtreme2/cnic.ko","./usr/share/smartupdate/kmod-netxtreme2/component.xml"],"md5sum":"ecd98da003842a6be36aa8631223173d","name":"kmod-netxtreme2-7.14.80-6.rhel8u3.x86_64.rpm","release":"2021-08-11T16:05:08","revision":"0","sha1sum":"c41ea85e064d00bea93c6b88b72ab3e18166419d","size":"8MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec9fda3d1e"],"type_of_change":"0","version":"7.14.80-6"}],"id":{"product":"9f8f92dcaee7444992d11c0fa284d349","version":"6b71fe40147746f59e7add1a33f9b28e"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>Download README for any additional installation instructions.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE QLogic NX2 10/20 GbEマルチファンクションドライバーfor Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"168E","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c339d","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c18d3","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1930","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c193a","type":"pci","ven":"14E4"},{"dev":"16A1","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a1159000ec","type":"pci","ven":"1077"},{"dev":"16AF","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c339d","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c18d3","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c193a","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1930","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1933","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1931","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1917","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"3382","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c3382","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c339d","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c193a","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1930","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16ad159000ec","type":"pci","ven":"1077"},{"dev":"16A4","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a4159000ec","type":"pci","ven":"1077"},{"dev":"16AE","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1931","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16af15908148","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ae15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-168e15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1931","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 8, Updates 2&nbsp;and 3.</p>\n","latest_fixes_x_late":"<p>This product corrects an issue obtain Medium Dependent Interface(MDI) and Medium Dependent Interface Crossover (MDIX) information when execution ethtool tools</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>This product now supports MDI(Medium Dependent Interface)/MDIX(Medium Dependent Interface Crossover) connection status to ethtool.</li>\n\t<li>This product now supports Timestamping the unicast Precision Time Protocol (PTP) packets.</li>\n\t<li>This product now supports Red Hat Enterprise Linux 8 update 4</li>\n</ul>\n","curr_fixes_x_late":"<p>This product addresses an issue where Virtual Local Area Networks(VLANs) resource accounting when linux driver creating 272 Virtual Local Area Networks(VLANs) on single Virtual Functions, then enable interface after closed.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-netxtreme2","sw_key_expectedpath":"software:rpm"},{"name":"kmod-netxtreme2","sw_key_expectedpath":"software:rpm"},{"name":"kmod-netxtreme2","sw_key_expectedpath":"software:rpm"},{"name":"kmod-netxtreme2","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under Red Hat Enterprise Linux 8 Update 2."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"25192","datemodified":"2021-02-11T01:05:26","file_list":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib/.build-id","./usr/lib/.build-id/99","./usr/lib/.build-id/99/2d3ab5d9085915f48edcbc531702436c72fb53","./usr/lib64/libbnxt_re-218.0.7.0.so","./usr/lib64/libbnxt_re-rdmav25.so","./usr/lib64/libbnxt_re.so","./usr/share/smartupdate/libbnxt_re/component.xml"],"md5sum":"22b00b36be7f99a9a827c2f382c7acfc","name":"libbnxt_re-218.0.7.0-rhel8u2.x86_64.rpm","release":"2021-02-11T01:02:04","revision":"0","sha1sum":"be366120973b74019a8d48f7255610407840bb13","size":"24KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"type_of_change":"0","version":"218.0.7.0"}],"id":{"product":"67c1e7cc9a5f4a98b6e37ff05556aec1","version":"228b5255801449f6a047211f91a3c05e"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"text-align:left\">rpm -ivh &lt;bnxt_rooce &gt;.rpm --force [--replacefiles]</p>\n\n<p style=\"text-align:left\">Use --force or --replacefiles options while installing or updating the HPE Broadcom RoCE library which may conflict with inbox library</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E RoCE Library for Red Hat Enterprise Linux 8 Update 2."}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"libbnxt_re","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 adapter cards."},{"lang":"ja","x_late":"このRPMには、サポートされているHPE Mellanox ConnectX-4、ConnectX-5、およびConnectX-6アダプターカード用のHPEによるテストと承認済みのLinuxベースMellanox RoCE（RDMA over Converged Ethernet）ドライバーが含まれます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1661261","datemodified":"2021-07-21T07:06:35","file_list":["./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/compat","./lib/modules/5.3.18-22-default/updates/compat/mlx_compat.ko","./lib/modules/5.3.18-22-default/updates/drivers","./lib/modules/5.3.18-22-default/updates/drivers/base","./lib/modules/5.3.18-22-default/updates/drivers/base/auxiliary.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/ib_cm.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/ib_core.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/ib_ucm.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/ib_umad.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/iw_cm.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/rdma_cm.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/cxgb3","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/cxgb3/iw_cxgb3.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/cxgb4","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/efa","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/efa/efa.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/hfi1","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/i40iw","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/mlx4","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/mlx5","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/mthca","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/mthca/ib_mthca.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/ocrdma","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/ocrdma/ocrdma.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/qedr","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/qib","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/qib/ib_qib.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/usnic","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/sw","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/sw/rdmavt","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/sw/rxe","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/sw/siw","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/sw/siw/siw.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/ipoib","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/iser","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/isert","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/opa_vnic","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/srp","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/srpt","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/5.3.18-22-default/updates/drivers/net","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlx5","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/5.3.18-22-default/updates/drivers/nvme","./lib/modules/5.3.18-22-default/updates/drivers/nvme/host","./lib/modules/5.3.18-22-default/updates/drivers/nvme/host/nvme-rdma.ko","./lib/modules/5.3.18-22-default/updates/drivers/nvme/target","./lib/modules/5.3.18-22-default/updates/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/5.3.18-22-default/updates/net","./lib/modules/5.3.18-22-default/updates/net/9p","./lib/modules/5.3.18-22-default/updates/net/9p/9pnet_rdma.ko","./lib/modules/5.3.18-22-default/updates/net/mlxdevm","./lib/modules/5.3.18-22-default/updates/net/mlxdevm/mlxdevm.ko","./lib/modules/5.3.18-22-default/updates/net/rds","./lib/modules/5.3.18-22-default/updates/net/rds/rds_rdma.ko","./lib/modules/5.3.18-22-default/updates/net/sunrpc","./lib/modules/5.3.18-22-default/updates/net/sunrpc/xprtrdma","./lib/modules/5.3.18-22-default/updates/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/5.3.18-22-default/updates/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/5.3.18-22-default/updates/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/mlnx-ofa_kernel-kmp-default/component.xml"],"md5sum":"091889491ac6cdb8ad49df109e449e17","name":"mlnx-ofa_kernel-kmp-default-5.4_k5.3.18_22-OFED.5.4.1.0.3.1.sles15sp2.x86_64.rpm","release":"2021-07-21T05:56:18","revision":"0","sha1sum":"e6432d141fc07099c19ee0f46185c92745511b97","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"5.4"},{"bytes":"1378818","datemodified":"2021-07-21T07:09:20","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/rdma","./etc/rdma/mlx4.conf","./etc/rdma/modules","./etc/rdma/modules/rdma.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/70-persistent-ipoib.rules","./lib/udev/auxdev-sf-netdev-rename","./lib/udev/mlnx_bf_udev","./lib/udev/rules.d/82-net-setup-link.rules","./lib/udev/rules.d/83-mlnx-sf-name.rules","./lib/udev/rules.d/90-ib.rules","./lib/udev/sf-rep-netdev-rename","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/mlnx_bf_configure_ct","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_perf","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/include/mellanox/dpcp.h","./usr/lib/dracut","./usr/lib/dracut/modules.d","./usr/lib/dracut/modules.d/05rdma","./usr/lib/dracut/modules.d/05rdma/module-setup.sh","./usr/lib/mlx4-setup.sh","./usr/lib/modprobe.d","./usr/lib/modprobe.d/libmlx4.conf","./usr/lib/python2.7/site-packages/__pycache__/dcbnetlink.cpython-36.opt-1.pyc","./usr/lib/python2.7/site-packages/__pycache__/dcbnetlink.cpython-36.pyc","./usr/lib/python2.7/site-packages/__pycache__/genetlink.cpython-36.opt-1.pyc","./usr/lib/python2.7/site-packages/__pycache__/genetlink.cpython-36.pyc","./usr/lib/python2.7/site-packages/__pycache__/netlink.cpython-36.opt-1.pyc","./usr/lib/python2.7/site-packages/__pycache__/netlink.cpython-36.pyc","./usr/lib/python2.7/site-packages/dcbnetlink.py","./usr/lib/python2.7/site-packages/genetlink.py","./usr/lib/python2.7/site-packages/mlnx_tools-5.2.0-py3.6.egg-info","./usr/lib/python2.7/site-packages/netlink.py","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/rdma-ndd.service","./usr/lib/systemd/system/vma.service","./usr/lib/udev/rdma_rename","./usr/lib/udev/rules.d","./usr/lib/udev/rules.d/60-rdma-ndd.rules","./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules","./usr/lib/udev/rules.d/75-rdma-description.rules","./usr/lib/udev/rules.d/90-rdma-umad.rules","./usr/lib64/libdpcp.so","./usr/lib64/libdpcp.so.1","./usr/lib64/libdpcp.so.1.1.12","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.35.0","./usr/lib64/libibverbs","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.14.35.0","./usr/lib64/libibverbs/libmlx5-rdmav34.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.19.35.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.3.35.0","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.3.1","./usr/lib64/rsocket","./usr/lib64/rsocket/librspreload.so","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/ibdev2netdev","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/rdma-ndd","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vmad","./usr/share/doc/packages/dpcp","./usr/share/doc/packages/dpcp/README","./usr/share/doc/packages/libibverbs","./usr/share/doc/packages/libibverbs/libibverbs.md","./usr/share/doc/packages/librdmacm","./usr/share/doc/packages/librdmacm/librdmacm.md","./usr/share/doc/packages/libvma-9.3.1","./usr/share/doc/packages/libvma-9.3.1/CHANGES","./usr/share/doc/packages/libvma-9.3.1/README","./usr/share/doc/packages/mlnx-tools","./usr/share/doc/packages/mlnx-tools/ib2ib_setup.txt","./usr/share/doc/packages/rdma-core","./usr/share/doc/packages/rdma-core/COPYING.BSD_FB","./usr/share/doc/packages/rdma-core/COPYING.BSD_MIT","./usr/share/doc/packages/rdma-core/COPYING.GPL2","./usr/share/doc/packages/rdma-core/COPYING.md","./usr/share/doc/packages/rdma-core/README.md","./usr/share/doc/packages/rdma-core/tag_matching.md","./usr/share/doc/packages/rdma-core/udev.md","./usr/share/licenses/dpcp","./usr/share/licenses/dpcp/LICENSE","./usr/share/licenses/libvma","./usr/share/licenses/libvma/COPYING","./usr/share/man/man7/rsocket.7.gz","./usr/share/man/man7/vma.7.gz","./usr/share/man/man8/ib2ib_setup.8.gz","./usr/share/man/man8/rdma-ndd.8.gz","./usr/share/man/man8/vmad.8.gz","./usr/share/mlnx_ofed/mlnx_bf_assign_ct_cores.sh","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml"],"md5sum":"4d47f9d6df2f840a4004d8a5183ee095","name":"mlnx-ofa_kernel-5.4-OFED.5.4.1.0.3.1.sles15sp2.x86_64.rpm","release":"2021-07-21T05:56:18","revision":"0","sha1sum":"a7bd158e7f8a549ccf59cbeda4a5f783e813778a","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"5.4"}],"id":{"product":"725f060c9eaa4196aa47bcf7495820ec","version":"143814472b294452b41a70eeb3e07f68"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"11.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPMs to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-5.4&quot; RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using 5.3.18-22-default&nbsp;kernel or any future errata:<br />\n<br />\n<strong># rpm -Uvh&nbsp;mlnx-ofa_kernel-5.4-OFED.5.4.0.5.1.1.sles15sp2.x86_64.rpm mlnx-ofa_kernel-kmp-default-5.4_k5.3.18_22-OFED.5.4.0.5.1.1.sles15sp2.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 Adapters for SUSE LINUX Enterprise Server 15 SP2 (AMD64/EM64T)"},{"lang":"ja","x_late":"HPE Mellanox RoCE（RDMA over Converged Ethernet）ドライバーfor Mellanox ConnectX-4、ConnectX-5、ConnectX-6 Adapters for SUSE LINUX Enterprise Server 15 SP2 (AMD64/EM64T)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"101f","subdev":"0012","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30012","type":"pci","ven":"15b3"},{"dev":"101f","subdev":"0007","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30007","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"032D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-10171590032d","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T17:11:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Changes and new features in HPE Mellanox RoCE driver&nbsp;version 5.2:</strong></p>\n\n<p><strong>For ConnectX-5 Adapters and above:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>CQE compression support for Rx multi-strides packets.</li>\n\t\t<li>Configuring QoS on a single QP or on a group of QPs.</li>\n\t\t<li>Encap/decap hardware offload of IPv4 traffic over MPLS-over-UDP. This can be used in networks with MPLS routers to achieve more efficient routing.</li>\n\t\t<li>Connection tracking rules on VFs to forward traffic from one VF to the other.</li>\n\t\t<li>Offloading sFlow sampling rules.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For ConnectX-5 Adapters and ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>A locking mechanism to enable parallel insertion of rules into the software steering using the mlx5dv_dr API. The parallel insertion improves the insertion rate and takes place when adding Rx and Tx rules via the FDB domain.</li>\n\t\t<li>Option to match mlx5dv_dr API on Geneve tunnel using a dynamic flex parser. The option header consists of class, type, length and data. The parser should be configured using devx command, after which a rule can be created to match on parser ID and data.</li>\n\t\t<li>Geneve tunneling offload, including matching on extension header.</li>\n\t\t<li>Parallel insertion and deletion of offloaded rules using multiple&nbsp;OVS threads.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>[Beta] Modify GTP-U TEID. This support requires flex parser&nbsp;configuration.</li>\n\t\t<li>[Beta] Improved performance of OVS Connection Tracking flows by&nbsp;enabling the merge of the multi-table flow matches and actions into one joint flow.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Dx Adapters and above:</strong></p>\n\n<p>Added support for the following features:</p>\n\n<ul>\n\t<li>Transmitted packet timestamping accuracy can be improved when using a timestamp generated at the port level instead of a timestamp generated upon CQE creation. Tx port time-stamping better reflects the actual time of a packet&#39;s transmission. This feature is disabled by default. The feature can be enabled or disabled using the following command. ethtool --set-priv-flags tx_port_ts on / off.</li>\n\t<li>Offloading tunnel rules when the source interface is VF (in addition to uplink) in the Hypervisor.</li>\n\t<li>Using Mirroring Offload with Connection Tracking.</li>\n\t<li>ASO flow meter using the mlx5dv_dr API, which allows for monitoring the packet rate for specific flows. When a packet hits a flow that is connected to a flow meter, the rate of packets through this meter is evaluated, and the packet is marked with a color copied into one of the C registers, according to the current rate compared to the reference rate.</li>\n\t<li>ASO first hit using the mlx5dv_dr API, which allows for tracking rule hits by packets. When a packet hits a rule with the ASO first hit action, a flag is set indicating this event, and the original value of the flag is copied to one of the C registers.</li>\n\t<li>mlx5dv_dr API support for matching on a new field &quot;gtpu_first_ext_dw_0&quot;. This field enables packet filtering based on the GTP-U first extension header (first dword only). To enable parsing of tunnel GTP-U extension header, run the following command. ./cloud_fw_reset.py FLEX_PARSER_PROFILE_ENABLE=3.</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Lx Adapters and above:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>IPsec full offload support for extended sequence number, replay protection window and lifetime packet limit.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;All HCA&#39;s:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>New query GID API that allows for querying a single GID entry by its port and GID index, or querying for all GID tables of a specific device. This API works over ioctl instead of sysfs, which accelerates the querying process.</li>\n\t\t<li>Performing multi-host firmware reset in order to upgrade the device firmware. Firmware reset loads the new firmware in case it was burnt on the flash and was pending activation, and reload.</li>\n\t\t<li>[Alpha] Firmware live patching in the driver. Live patching updates the firmware without the need to perform firmware reset. However, it can only be applied in scenarios where the difference between the current and new firmware versions are minor, which is decided upon by the firmware itself.</li>\n\t\t<li>devlink tool for performing firmware reset in order to upgrade the device firmware. Firmware reset loads the new firmware in case it was burnt on the flash and was pending activation, and reloads the current firmware image from the flash in case no new firmware was pending. For further information, please refer to the the devlink man page.</li>\n\t\t<li>A resiliency mechanism for the driver to manually poll the command event queue (EQ) in case of a command timeout. In case the resiliency mechanism finds unhandled event queue entry (EQE) due to a lost interrupt, the driver will handle it, after which the command interface returns to a healthy state.</li>\n\t\t<li>Setting a sniffer private flag is deprecated and no longer required. In order to capture offloaded/RoCE traffic, tcpdump can now be run on the RDMA device.</li>\n\t\t<li>Added per-port reporters to devlink health to manage per-port health activities. Users can now access the devlink port reporters by specifying the port index in addition to the device devlink name through the devlink health commands API. This update was first introduced in iproute2 v5.8. As part of this feature, mlx5e Tx and Rx reporters are now redefined as devlink port reporters. For examples, please see devlink-health manpage</li>\n\t\t<li>Optimized memory consumption of memory registration in huge page systems. As an example, in a 2MB huge page system, 600 MB would be saved for 100 GB memory registration.</li>\n\t\t<li>mlx5dv API to modify the configured UDP source port for RoCE packets of a given RC/UC QP when QP is in RTS state.</li>\n\t\t<li>Accelerating Tx datapath by saving PCI bandwidth and CPU utilization. The savings are achieved by aggregating multiple packets into a single WQE. The feature is driven by xmit_more for certain traffic types, such as UDP.</li>\n\t</ul>\n\t</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 5.2:</strong></p>\n\n<ul>\n\t<li>Clearing min_rate on all SR-IOV legacy VFs after setting min_rate to at least one of the VFs did not disable QoS min_rate.</li>\n\t<li>An empty /usr/src/mlnx-ofa_kernel/default is now no longer created.</li>\n\t<li>An issue where installing packages through a repository failed after generation of metapackages using --add-kernel-support. The failure occurred due to excessive and incorrect Obsolete headers in those metapackages.Enabled installation of mlnx-ofa_kernel package to /bin/python3 instead of / usr/bin/python3 on RHEL 8.x systems.</li>\n\t<li>All IPoIB offload packets were wrongly counted as rx_csum_complete. These packets are now identified as rx_csum_unnecessary packets.</li>\n\t<li>mlx5dv_dr_rule_destroy segmentation fault could happen in rare cases with multiple rules on the same matcher with a different number of actions. This could happen after reusing an already deleted rule memory with less actions.</li>\n\t<li>An issue of moving to SwitchDev mode after configuring DSCP (Differentiated Service Code Point).</li>\n\t<li>Global traffic class configuration did not take effect on DC QPs (Dynamically Connected Queue Pairs).</li>\n\t<li>ib_send_bw traffic frequently dropped to zero when RDMA CM was used, because of incorrect&nbsp;min_rnr_timer setting on the responder side. The min_rnr_timer setting is now aligned with the setting in non-RDMA CM cases.</li>\n\t<li>Traffic did not pass over VFs with VST QinQ feature is enabled.</li>\n\t<li>When traffic was sent over Geneve VLAN with Tx VLAN offload enabled and TSO (TCP Segmentation Offload)&nbsp;or Tx csum enabled, traffic could be dropped and not sent to the wire.</li>\n\t<li>An issue that caused the firmware to restart upon installing mlnxofed-dpdk-upstream-libs package manually.</li>\n\t<li>Bad utility paths in rdma-core &quot;dracut&quot; hooks on SLES systems, which used to result in the following errors when running &quot;dracut&quot; with the &quot;--add rdma&quot; option. dracut-install:\n\t<ul>\n\t\t<li>ERROR: installing &lsquo;/usr/libexec/mlx4-setup.sh&rsquo; dracut: /usr/lib/dracut/dracut-install -D /var/tmp/dracut.UdCOSJ/ initramfs /usr/libexec/mlx4-setup.sh dracut-install: ERROR: installing &lsquo;/usr/libexec/rdma-set-sriov-vf&rsquo; dracut: /usr/lib/dracut/dracut-install -D /var/tmp/dracut.UdCOSJ/ initramfs /usr/libexec/rdma-set-sriov-vf</li>\n\t</ul>\n\t</li>\n\t<li>Traffic class value was not updated in DCT when set via sysfs.</li>\n\t<li>A doorbell loss issue on AMD platforms with Secure Memory Encryption (SME).</li>\n\t<li>Registering memory using mlx5dv_devx_umem_reg while forking. Without this fix, applications which use fork() or similar syscalls while using a memory registered with umem_reg could hang due to incorrect physical page mapping. This fix requires setting the IBV_FORK_SAFE environment variable.</li>\n\t<li>When&nbsp;unbinding the device resulted in the following message being printed to the dmesg: &quot;failed to disable DC tracer&quot;</li>\n\t<li>Content of file /sys/class/net//statistics/ multicast might have been out of date and might have displayed values lower than the real values.</li>\n\t<li>ERSPAN (Encapsulated Remote SPAN) protocol was available only when turning off Tx checksum offload.</li>\n\t<li>A udev script issue which caused non-mellanox devices to be renamed.</li>\n\t<li>Missing representor statistics when using ifconfig.</li>\n\t<li>Fixed wrong value of skb mark of received packets on representors.</li>\n\t<li>An issue which caused second port representors to be named as first port representors.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Changes and new features in HPE Mellanox RoCE driver&nbsp;version 5.3:</strong></p>\n\n<p><strong>For ConnectX-5 Adapters and above:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>CQE compression support for Rx multi-strides packets.</li>\n\t\t<li>Configuring QoS on a single QP or on a group of QPs.</li>\n\t\t<li>Encap/decap hardware offload of IPv4 traffic over MPLS-over-UDP. This can be used in networks with MPLS routers to achieve more efficient routing.</li>\n\t\t<li>Connection tracking rules on VFs to forward traffic from one VF to the other.</li>\n\t\t<li>Offloading sFlow sampling rules.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For ConnectX-5 Adapters and ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>A locking mechanism to enable parallel insertion of rules into the software steering using the mlx5dv_dr API. The parallel insertion improves the insertion rate and takes place when adding Rx and Tx rules via the FDB domain.</li>\n\t\t<li>Option to match mlx5dv_dr API on Geneve tunnel using a dynamic flex parser. The option header consists of class, type, length and data. The parser should be configured using devx command, after which a rule can be created to match on parser ID and data.</li>\n\t\t<li>Geneve tunneling offload, including matching on extension header.</li>\n\t\t<li>Parallel insertion and deletion of offloaded rules using multiple&nbsp;OVS threads.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>[Beta] Modify GTP-U TEID. This support requires flex parser&nbsp;configuration.</li>\n\t\t<li>[Beta] Improved performance of OVS Connection Tracking flows by&nbsp;enabling the merge of the multi-table flow matches and actions into one joint flow.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Dx Adapters and above:</strong></p>\n\n<p>Added support for the following features:</p>\n\n<ul>\n\t<li>Transmitted packet timestamping accuracy can be improved when using a timestamp generated at the port level instead of a timestamp generated upon CQE creation. Tx port time-stamping better reflects the actual time of a packet&#39;s transmission. This feature is disabled by default. The feature can be enabled or disabled using the following command. ethtool --set-priv-flags tx_port_ts on / off.</li>\n\t<li>Offloading tunnel rules when the source interface is VF (in addition to uplink) in the Hypervisor.</li>\n\t<li>Using Mirroring Offload with Connection Tracking.</li>\n\t<li>ASO flow meter using the mlx5dv_dr API, which allows for monitoring the packet rate for specific flows. When a packet hits a flow that is connected to a flow meter, the rate of packets through this meter is evaluated, and the packet is marked with a color copied into one of the C registers, according to the current rate compared to the reference rate.</li>\n\t<li>ASO first hit using the mlx5dv_dr API, which allows for tracking rule hits by packets. When a packet hits a rule with the ASO first hit action, a flag is set indicating this event, and the original value of the flag is copied to one of the C registers.</li>\n\t<li>mlx5dv_dr API support for matching on a new field &quot;gtpu_first_ext_dw_0&quot;. This field enables packet filtering based on the GTP-U first extension header (first dword only). To enable parsing of tunnel GTP-U extension header, run the following command. ./cloud_fw_reset.py FLEX_PARSER_PROFILE_ENABLE=3.</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Lx Adapters and above:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>IPsec full offload support for extended sequence number, replay protection window and lifetime packet limit.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;All HCA&#39;s:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>New query GID API that allows for querying a single GID entry by its port and GID index, or querying for all GID tables of a specific device. This API works over ioctl instead of sysfs, which accelerates the querying process.</li>\n\t\t<li>Performing multi-host firmware reset in order to upgrade the device firmware. Firmware reset loads the new firmware in case it was burnt on the flash and was pending activation, and reload.</li>\n\t\t<li>[Alpha] Firmware live patching in the driver. Live patching updates the firmware without the need to perform firmware reset. However, it can only be applied in scenarios where the difference between the current and new firmware versions are minor, which is decided upon by the firmware itself.</li>\n\t\t<li>devlink tool for performing firmware reset in order to upgrade the device firmware. Firmware reset loads the new firmware in case it was burnt on the flash and was pending activation, and reloads the current firmware image from the flash in case no new firmware was pending. For further information, please refer to the the devlink man page.</li>\n\t\t<li>A resiliency mechanism for the driver to manually poll the command event queue (EQ) in case of a command timeout. In case the resiliency mechanism finds unhandled event queue entry (EQE) due to a lost interrupt, the driver will handle it, after which the command interface returns to a healthy state.</li>\n\t\t<li>Setting a sniffer private flag is deprecated and no longer required. In order to capture offloaded/RoCE traffic, tcpdump can now be run on the RDMA device.</li>\n\t\t<li>Added per-port reporters to devlink health to manage per-port health activities. Users can now access the devlink port reporters by specifying the port index in addition to the device devlink name through the devlink health commands API. This update was first introduced in iproute2 v5.8. As part of this feature, mlx5e Tx and Rx reporters are now redefined as devlink port reporters. For examples, please see devlink-health manpage</li>\n\t\t<li>Optimized memory consumption of memory registration in huge page systems. As an example, in a 2MB huge page system, 600 MB would be saved for 100 GB memory registration.</li>\n\t\t<li>mlx5dv API to modify the configured UDP source port for RoCE packets of a given RC/UC QP when QP is in RTS state.</li>\n\t\t<li>Accelerating Tx datapath by saving PCI bandwidth and CPU utilization. The savings are achieved by aggregating multiple packets into a single WQE. The feature is driven by xmit_more for certain traffic types, such as UDP.</li>\n\t</ul>\n\t</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 5.3:</strong></p>\n\n<ul>\n\t<li>Clearing min_rate on all SR-IOV legacy VFs after setting min_rate to at least one of the VFs did not disable QoS min_rate.</li>\n\t<li>An empty /usr/src/mlnx-ofa_kernel/default is now no longer created.</li>\n\t<li>An issue where installing packages through a repository failed after generation of metapackages using --add-kernel-support. The failure occurred due to excessive and incorrect Obsolete headers in those metapackages.Enabled installation of mlnx-ofa_kernel package to /bin/python3 instead of / usr/bin/python3 on RHEL 8.x systems.</li>\n\t<li>All IPoIB offload packets were wrongly counted as rx_csum_complete. These packets are now identified as rx_csum_unnecessary packets.</li>\n\t<li>mlx5dv_dr_rule_destroy segmentation fault could happen in rare cases with multiple rules on the same matcher with a different number of actions. This could happen after reusing an already deleted rule memory with less actions.</li>\n\t<li>An issue of moving to SwitchDev mode after configuring DSCP (Differentiated Service Code Point).</li>\n\t<li>Global traffic class configuration did not take effect on DC QPs (Dynamically Connected Queue Pairs).</li>\n\t<li>ib_send_bw traffic frequently dropped to zero when RDMA CM was used, because of incorrect&nbsp;min_rnr_timer setting on the responder side. The min_rnr_timer setting is now aligned with the setting in non-RDMA CM cases.</li>\n\t<li>Traffic did not pass over VFs with VST QinQ feature is enabled.</li>\n\t<li>When traffic was sent over Geneve VLAN with Tx VLAN offload enabled and TSO (TCP Segmentation Offload)&nbsp;or Tx csum enabled, traffic could be dropped and not sent to the wire.</li>\n\t<li>An issue that caused the firmware to restart upon installing mlnxofed-dpdk-upstream-libs package manually.</li>\n\t<li>Bad utility paths in rdma-core &quot;dracut&quot; hooks on SLES systems, which used to result in the following errors when running &quot;dracut&quot; with the &quot;--add rdma&quot; option. dracut-install:\n\t<ul>\n\t\t<li>ERROR: installing &lsquo;/usr/libexec/mlx4-setup.sh&rsquo; dracut: /usr/lib/dracut/dracut-install -D /var/tmp/dracut.UdCOSJ/ initramfs /usr/libexec/mlx4-setup.sh dracut-install: ERROR: installing &lsquo;/usr/libexec/rdma-set-sriov-vf&rsquo; dracut: /usr/lib/dracut/dracut-install -D /var/tmp/dracut.UdCOSJ/ initramfs /usr/libexec/rdma-set-sriov-vf</li>\n\t</ul>\n\t</li>\n\t<li>Traffic class value was not updated in DCT when set via sysfs.</li>\n\t<li>A doorbell loss issue on AMD platforms with Secure Memory Encryption (SME).</li>\n\t<li>Registering memory using mlx5dv_devx_umem_reg while forking. Without this fix, applications which use fork() or similar syscalls while using a memory registered with umem_reg could hang due to incorrect physical page mapping. This fix requires setting the IBV_FORK_SAFE environment variable.</li>\n\t<li>When&nbsp;unbinding the device resulted in the following message being printed to the dmesg: &quot;failed to disable DC tracer&quot;</li>\n\t<li>Content of file /sys/class/net//statistics/ multicast might have been out of date and might have displayed values lower than the real values.</li>\n\t<li>ERSPAN (Encapsulated Remote SPAN) protocol was available only when turning off Tx checksum offload.</li>\n\t<li>A udev script issue which caused non-mellanox devices to be renamed.</li>\n\t<li>Missing representor statistics when using ifconfig.</li>\n\t<li>Fixed wrong value of skb mark of received packets on representors.</li>\n\t<li>An issue which caused second port representors to be named as first port representors.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWSXF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757535846","Version":"HPG3"},{"DeviceName":"VK000960GWSXH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757535848","Version":"HPG3"},{"DeviceName":"VK001920GWSXK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-30475753584b","Version":"HPG3"},{"DeviceName":"MK000480GWUGF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757554746","Version":"HPG3"},{"DeviceName":"MK000960GWUGH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757554748","Version":"HPG3"},{"DeviceName":"MK001920GWUGK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475755474b","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000480GWSXF, VK000960GWSXH, VK001920GWSXK, MK000480GWUGF, MK000960GWUGH and MK001920GWUGK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK000480GWSXF, VK000960GWSXH, VK001920GWSXK, MK000480GWUGF, MK000960GWUGH and MK001920GWUGK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16481856","datemodified":"2021-08-27T10:31:13","file_list":["/CP048409_BUILD_3.data","/CP048409.vmexe","/CP048409.vmexe64","/CP048409.vmfile","/CP048409_VMw.zip","/CP048409.xml","/payload.json","/CP048409_VMw.zip/index.xml","/CP048409_VMw.zip/vendor-index.xml","/CP048409_VMw.zip/metadata.zip","/CP048409_VMw.zip/vib20/CP048409/HPE_bootbank_CP048409_HPG3.3-7.0.0.15843807.vib","/CP048409_VMw.zip/metadata.zip/vendor-index.xml","/CP048409_VMw.zip/metadata.zip/vmware.xml","/CP048409_VMw.zip/metadata.zip/vibs/CP048409-201601623260805544.xml","/CP048409_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048409_HPG3.3-7.0.0.15843807.xml"],"md5sum":"ca726d93748d8902722a4d93f0022c4e","name":"CP048409.zip","release":"2021-08-27T10:25:57","revision":"0","sha1sum":"d6641a7c29af4dba34391525628d663ba2c89066","size":"15MB","target_guids":["562340a5-304b-3030-3438-304757535846","562340a5-304b-3030-3936-304757535848","562340a5-304b-3130-3932-30475753584b","4d2340a5-304b-3030-3438-304757554746","4d2340a5-304b-3030-3936-304757554748","4d2340a5-304b-3130-3932-30475755474b"],"type_of_change":"1","version":"HPG3","vib_list":[{"name":"CP048409","version":"HPG3.3-7.0.0.15843807"}]}],"id":{"product":"f7ead10dcb9d4e3b81c19da679b23ce2","version":"c23b4256ca69412cb45e1aac0a24aba8"},"installation":{"command":"CP040788.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>HP Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK000480GWSXF, VK000960GWSXH, VK001920GWSXK, MK000480GWUGF, MK000960GWUGH and MK001920GWUGK Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VK000480GWSXF、VK000960GWSXH、VK001920GWSXK、MK000480GWUGF、 MK000960GWUGH、MK001920GWUGKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VK001920GWSXK","target_guid":"562340a5-304b-3130-3932-30475753584b","type":"sata"},{"id":"MK001920GWUGK","target_guid":"4d2340a5-304b-3130-3932-30475755474b","type":"sata"},{"id":"VK000960GWSXH","target_guid":"562340a5-304b-3030-3936-304757535848","type":"sata"},{"id":"MK000960GWUGH","target_guid":"4d2340a5-304b-3030-3936-304757554748","type":"sata"},{"id":"VK000480GWSXF","target_guid":"562340a5-304b-3030-3438-304757535846","type":"sata"},{"id":"MK000480GWUGF","target_guid":"4d2340a5-304b-3030-3438-304757554746","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T05:27:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Improved Product Quality and Reliability. Changed Cap Charge Timeout to 14 seconds from 4 seconds to provide additional time for cap charge in marginal power environment.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK000480GWUGF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK001920GWUGK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWUGH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWSXF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GWSXK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWSXH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWUDB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEBHssseFD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57554442","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB014000JWUDB"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB014000JWUDB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB014000JWUDB Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp;</strong> None</p>\n"}],"files":[{"bytes":"4355656","datemodified":"2021-07-23T05:55:11","file_list":["cp048563.xml","cpqsetup.exe","HLEBHssseFD3.rel","payload.json","setup.dll"],"md5sum":"0edd8a8162823b9c34afcacf924f9a65","name":"cp048563.exe","release":"2021-07-23T05:47:07","revision":"0","sha1sum":"cbe97453577cac106b87c610f5ac6bc1f9f8c6a0","size":"4MB","target_guids":["4d2340a5-3042-3431-3030-304a57554442"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"83ce77cbc6db45d29c95de38716f222e","version":"b872dedf403047a9ad1ef20e55455eb2"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB014000JWUDB Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB014000JWUDB ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB014000JWUDB","target_guid":"4d2340a5-3042-3431-3030-304a57554442","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T07:00:39","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to &ldquo;HPE&rdquo;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB014000JWUDB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HP FlexFabric 10Gb 2-port 534M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C1933","Version":"7.18.82"},{"DeviceName":"HP FlexFabric 10Gb 2-port 536FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16A2103C22FA","Version":"7.18.82"},{"DeviceName":"HP FlexFabric 20Gb 2-port 630M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16A2103C1917","Version":"7.18.82"},{"DeviceName":"HPE FlexFabric 20Gb 2-port 630FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16A2103C1916","Version":"7.18.82"},{"DeviceName":"HP NPAR 10Gb 2-port 534M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C1933","Version":"7.18.82"},{"DeviceName":"HP NPAR 10Gb 2-port 536FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16A4103C22FA","Version":"7.18.82"},{"DeviceName":"HP NPAR 20Gb 2-port 630FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16A4103C1916","Version":"7.18.82"},{"DeviceName":"HP NPAR 20Gb 2-port 630M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16A4103C1917","Version":"7.18.82"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Blade QLogic NX2 Gigabit Ethernet NICs Boot code (MFW), PXE, UEFI, iSCSI, FCoE, CCM and L2 code running under Linux platforms."},{"lang":"ja","x_late":"このパッケージには、Linux プラットフォームで動作するHPE Blade QLogic NX2 Gigabit Ethernet NICブートコード、MFW、PXE、UEFI、iSCSI、FCoE、CCMおよびL2コードをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains combo image v7.18.82 with the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"2\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>NIC</strong></td>\n\t\t\t<td><strong>Boot Code Version</strong></td>\n\t\t\t<td><strong>PXE Version</strong></td>\n\t\t\t<td><strong>UEFI Version</strong></td>\n\t\t\t<td><strong>iSCSI Version</strong></td>\n\t\t\t<td><strong>FCoE Version</strong></td>\n\t\t\t<td><strong>CCM Version</strong></td>\n\t\t\t<td><strong>L2 Version</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HP FlexFabric 10Gb 2-port 534M Adapter<br />\n\t\t\tHP FlexFabric 10Gb 2-port 536FLB Adapter<br />\n\t\t\tHP FlexFabric 20Gb 2-port 630FLB Adapter<br />\n\t\t\tHP FlexFabric 20Gb 2-port 630M Adapter</td>\n\t\t\t<td>7.16.03</td>\n\t\t\t<td>7.14.13</td>\n\t\t\t<td>8.9.0</td>\n\t\t\t<td>7.14.0</td>\n\t\t\t<td>7.14.3</td>\n\t\t\t<td>7.14.4</td>\n\t\t\t<td>7.12.25</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"3155085","datemodified":"2021-08-16T16:47:19","file_list":["./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-bl-1.5.2-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-bl-1.5.2-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-bl-1.5.2-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-bl-1.5.2-1.1/CP047648.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-bl-1.5.2-1.1/CP047648.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-bl-1.5.2-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-bl-1.5.2-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-bl-1.5.2-1.1/deps/libs/libqlgc_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-bl-1.5.2-1.1/deps/libs/libtcl8.3.so","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-bl-1.5.2-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-bl-1.5.2-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-bl-1.5.2-1.1/nic_fw/hp_mbi_7.18.82.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-bl-1.5.2-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-bl-1.5.2-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP047648.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP047648.scexe"],"md5sum":"3af62345886d878cf4f9958ec039e49a","name":"firmware-nic-qlogic-nx2-bl-1.5.2-1.1.x86_64.rpm","release":"2021-08-16T16:39:03","revision":"0","sha1sum":"714072e00138f5bb60b904dd96fab3ad65910577","size":"3MB","target_guids":["a6b1a447-382a-5a4f-14E4-168E103C1933","a6b1a447-382a-5a4f-14E4-16A2103C22FA","a6b1a447-382a-5a4f-14E4-16A2103C1917","a6b1a447-382a-5a4f-14E4-16A2103C1916","a6b1a447-382a-5a4f-14E4-16AE103C1933","a6b1a447-382a-5a4f-14E4-16A4103C22FA","a6b1a447-382a-5a4f-14E4-16A4103C1916","a6b1a447-382a-5a4f-14E4-16A4103C1917"],"type_of_change":"0","version":"1.5.2"}],"id":{"product":"0b1755ac9ea74055988f525407cd9d18","version":"375091eba3814c0199caeceb07a68f44"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 7.6 version 7.14.63-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"7.6"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec63a13bba","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.14.63-1","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 7.6 version 7.14.63-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 7.7 version 7.14.63-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"7.7"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec63a13bba","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.14.63-1","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 7.7 version 7.14.63-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 8 version 7.14.63-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"8.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec63a13bba","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.14.63-1","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 8 version 7.14.63-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 12 version 7.14.63-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3da3feeb","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.14.63-1","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 12 version 7.14.63-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 12 version 7.14.63-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"12.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3da3feeb","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.14.63-1","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 12 version 7.14.63-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 15 version 7.14.63-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3da3feeb","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.14.63-1","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 15 version 7.14.63-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 15.1 version 7.14.63-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"15.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3da3feeb","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.14.63-1","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 15.1 version 7.14.63-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 1.0.87.0-1OEM.650.0.0.4598673 or greater is required and should be already active","OSVersion":{"name":"VMWare","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.87.0-1OEM.650.0.0.4598673","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 1.0.87.0-1OEM.650.0.0.4598673 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 1.0.87.0-1OEM.670.0.0.8169922 or greater is required and should be already active","OSVersion":{"name":"VMWare","value":"6.7"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.87.0-1OEM.670.0.0.8169922","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 1.0.87.0-1OEM.670.0.0.8169922 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 1.4.12.0-1OEM.700.1.0.15843807 or greater is required and should be already active","OSVersion":{"name":"VMWare","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.4.12.0-1OEM.700.1.0.15843807","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 1.4.12.0-1OEM.700.1.0.15843807 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 3.0.121.0-1OEM.700.1.0.15525992 or greater is required and should be already active","OSVersion":{"name":"VMWare","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"3.0.121.0-1OEM.700.1.0.15525992","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 3.0.121.0-1OEM.700.1.0.15525992 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><em><strong>Steps to update the adapter firmware using the rpm pacakge:</strong></em></p>\n\n<ul>\n\t<li>Install the firmware rpm package:<br />\n\t<em>&gt; rpm -ivh &lt;rpm_filename&gt;.rpm </em></li>\n\t<li>Check where the files are extracted:<br />\n\t<em>&gt; rpm -qlp &lt;rpm_filename&gt;.rpm</em></li>\n\t<li>Using the output from the previous step determine the location of hpsetup file, change to that directory and run &#39;<em>./hpsetup</em>&#39; to update the firmware.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li>\n\t<li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware, it merely extracts the contents of the rpm package to the local system. Updating the adapter firmware requires following the steps outlined above.</li>\n</ul>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade QLogic NX2 Online Firmware Upgrade Utility for Linux"},{"lang":"ja","x_late":"HPE Blade QLogic NX2オンラインファームウェアアップグレードユーティリティfor Linux"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"168E","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1933","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c22fa","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1917","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1916","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1933","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c22fa","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1916","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1917","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-03T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 7, Updates 8 and 9.<br />\nThis product now supports Red Hat Enterprise Linux 8, Updates 2&nbsp;and 3.<br />\nThis product now supports SUSE Linux Enterprise Server 12 SP5.<br />\nThis product now supports SUSE Linux Enterprise Server 15 SP2.</p>\n","latest_fixes_x_late":"<p>This product addresses an issue where powering on the system with any I/O virtualization functionality (NPAR, SR-IOV, etc) enabled results in an Uncorrectable Machine Check Exception (UMCE).<br />\nThis product addresses an issue where the WOL option is displayed on the Human Interface Infrastructure (HII) menu for 534M and 630M mezzanine devices, even though WOL is not supported on those devices.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 8 Update 4.<br />\nThis product now supports SuSE Linux Enterprise Server 15 SP3.</p>\n","curr_fixes_x_late":"<p>This product addresses an issue where the Maximum Transmission Unit (MTU) value of iSCSI function port is displayed as 0 bytes in AHS log.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"QLOGIC_NX2_BL","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under SUSE Linux Enterprise Server 15 SP2."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"22652","datemodified":"2021-02-11T00:37:49","file_list":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib64/libbnxt_re-218.0.7.0.so","./usr/lib64/libbnxt_re-rdmav25.so","./usr/lib64/libbnxt_re.so","./usr/share/smartupdate/libbnxt_re/component.xml"],"md5sum":"df5b9fcd1303f253ae6b45ba4439172c","name":"libbnxt_re-218.0.7.0-sles15sp2.x86_64.rpm","release":"2021-02-11T00:33:08","revision":"0","sha1sum":"012efcbae595aad4bb61490823111fb020fcb8a6","size":"22KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"type_of_change":"0","version":"218.0.7.0"}],"id":{"product":"ae3d91fc556c4e44b780b594f473e350","version":"1a1a8d6697e04bd09b91ba9e90cd9022"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"text-align:left\">rpm -ivh &lt;bnxt_rooce &gt;.rpm --force [--replacefiles]</p>\n\n<p style=\"text-align:left\">Use --force or --replacefiles options while installing or updating the HPE Broadcom RoCE library which may conflict with inbox library</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E RoCE Library for SUSE Linux Enterprise Server 15 SP2"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"libbnxt_re","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the NIC and RoCE drivers for HPE Broadcom NetXtreme-E devices running under VMware vSphere 6.7."},{"lang":"ja","x_late":"この製品は、VMware vSphere 6.7下で動作するHPE Broadcom NetXtreme-Eデバイス用のNICおよびRoCEドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains NIC driver version&nbsp;218.0.38.0 and RoCE driver version&nbsp;218.0.16.0.</p>\n"}],"files":[{"bytes":"364786","datemodified":"2021-01-14T06:16:23","file_list":["/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.670.0.0.8169922-offline_bundle-17341386.zip","/cp045074.xml","/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.670.0.0.8169922-offline_bundle-17341386.zip/index.xml","/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.670.0.0.8169922-offline_bundle-17341386.zip/vendor-index.xml","/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.670.0.0.8169922-offline_bundle-17341386.zip/metadata.zip","/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.670.0.0.8169922-offline_bundle-17341386.zip/vib20/bnxtroce/BCM_bootbank_bnxtroce_218.0.16.0-1OEM.670.0.0.8169922.vib","/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.670.0.0.8169922-offline_bundle-17341386.zip/vib20/bnxtnet/BCM_bootbank_bnxtnet_218.0.38.0-1OEM.670.0.0.8169922.vib","/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.670.0.0.8169922-offline_bundle-17341386.zip/metadata.zip/vendor-index.xml","/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.670.0.0.8169922-offline_bundle-17341386.zip/metadata.zip/vmware.xml","/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.670.0.0.8169922-offline_bundle-17341386.zip/metadata.zip/vibs/bnxtroce--6521842855526875576.xml","/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.670.0.0.8169922-offline_bundle-17341386.zip/metadata.zip/vibs/bnxtnet--8154265287820674143.xml","/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.670.0.0.8169922-offline_bundle-17341386.zip/metadata.zip/bulletins/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.670.0.0.8169922.xml"],"md5sum":"9d6a615cb7894e2abadf37f91e7a3aa7","name":"cp045074.zip","release":"2021-01-14T06:15:04","revision":"0","sha1sum":"006f3f62ab73f953570e0d22f68fb7661fa8fbfa","size":"356KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec158e843a","20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476"],"type_of_change":"0","version":"2021.04.05","vib_list":[{"name":"bnxtroce","version":"218.0.16.0-1OEM.670.0.0.8169922"},{"name":"bnxtnet","version":"218.0.38.0-1OEM.670.0.0.8169922"}]}],"id":{"product":"8cec45e9870e4e5fad3d7d2b3b545e8d","version":"3555fcf212c94841b362d82dc76d07fb"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere 6.7"},{"lang":"ja","x_late":"HPE Broadcom NetXtreme-E ドライバー for VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue where RDMA Ethernet Controller error description on ESXi Host.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product corrects an issue which Purple Screen Of Death (PSOD) while running &nbsp;Virtual SAN (vSAN) over &nbsp;Remote Direct Memory Access (RDMA) traffic due to invalid Completion Queue Element (CQEs)</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"bnxtnet:218.0.38.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"bnxtroce:218.0.16.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000300JWBHR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SEnD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57424852","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: EG000300JWBHR"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EG000300JWBHR"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG000300JWBHR Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"16238653","datemodified":"2021-09-24T10:09:20","file_list":["/CP048248_BUILD_2.data","/CP048248.vmexe","/CP048248.vmexe64","/CP048248.vmfile","/CP048248_VMw.zip","/CP048248.xml","/payload.json","/CP048248_VMw.zip/index.xml","/CP048248_VMw.zip/vendor-index.xml","/CP048248_VMw.zip/metadata.zip","/CP048248_VMw.zip/vib20/CP048248/HPE_bootbank_CP048248_HPD5.2-7.0.0.15843807.vib","/CP048248_VMw.zip/metadata.zip/vendor-index.xml","/CP048248_VMw.zip/metadata.zip/vmware.xml","/CP048248_VMw.zip/metadata.zip/vibs/CP048248-1721123927654259357.xml","/CP048248_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048248_HPD5.2-7.0.0.15843807.xml"],"md5sum":"9668b7b56f2d5922edadbed735cea20d","name":"CP048248.zip","release":"2021-09-24T10:03:19","revision":"0","sha1sum":"9746e5b02dcd98abcfdae8baf882a25e0a211eae","size":"15MB","target_guids":["452340a5-3047-3030-3330-304a57424852"],"type_of_change":"1","version":"HPD5","vib_list":[{"name":"CP048248","version":"HPD5.2-7.0.0.15843807"}]}],"id":{"product":"2a7080d78048494dac265180eef80ae1","version":"7886b4a69c3644d2980cf46552a4ae55"},"installation":{"command":"CP040530.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - EG000300JWBHR Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EG000300JWBHRドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG000300JWBHR","target_guid":"452340a5-3047-3030-3330-304a57424852","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-02T05:04:15","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>A low-probability, high severity corner case of sustained outer-diameter activity with emergency power off when heads are at the outer diameter prevented heads from parking/latching properly on a few drives in the field.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG000300JWBHR","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 adapter cards."},{"lang":"ja","x_late":"このRPMには、サポートされているHPE Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 アダプターカード用のHPEによるテストと承認済みのLinuxベースMellanox RoCE (RDMA over Converged Ethernet)ドライバーが含まれます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1303003","datemodified":"2021-07-13T07:56:52","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/rdma","./etc/rdma/mlx4.conf","./etc/rdma/modules","./etc/rdma/modules/rdma.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/70-persistent-ipoib.rules","./lib/udev/auxdev-sf-netdev-rename","./lib/udev/mlnx_bf_udev","./lib/udev/rules.d/82-net-setup-link.rules","./lib/udev/rules.d/83-mlnx-sf-name.rules","./lib/udev/rules.d/90-ib.rules","./lib/udev/sf-rep-netdev-rename","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/mlnx_bf_configure_ct","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_perf","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/include/mellanox/dpcp.h","./usr/lib/dracut","./usr/lib/dracut/modules.d","./usr/lib/dracut/modules.d/05rdma","./usr/lib/dracut/modules.d/05rdma/module-setup.sh","./usr/lib/modprobe.d","./usr/lib/modprobe.d/libmlx4.conf","./usr/lib/python2.7/site-packages/dcbnetlink.py","./usr/lib/python2.7/site-packages/genetlink.py","./usr/lib/python2.7/site-packages/mlnx_tools-5.2.0-py2.7.egg-info","./usr/lib/python2.7/site-packages/netlink.py","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/rdma-ndd.service","./usr/lib/systemd/system/vma.service","./usr/lib/udev/rdma_rename","./usr/lib/udev/rules.d","./usr/lib/udev/rules.d/60-rdma-ndd.rules","./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules","./usr/lib/udev/rules.d/75-rdma-description.rules","./usr/lib/udev/rules.d/90-rdma-umad.rules","./usr/lib64/libdpcp.so","./usr/lib64/libdpcp.so.1","./usr/lib64/libdpcp.so.1.1.12","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.35.0","./usr/lib64/libibverbs","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.14.35.0","./usr/lib64/libibverbs/libmlx5-rdmav34.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.19.35.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.3.35.0","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.3.1","./usr/lib64/rsocket","./usr/lib64/rsocket/librspreload.so","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/libexec/mlx4-setup.sh","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/ibdev2netdev","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/rdma-ndd","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vmad","./usr/share/doc/dpcp-1.1.12","./usr/share/doc/dpcp-1.1.12/README","./usr/share/doc/libibverbs-54mlnx1","./usr/share/doc/libibverbs-54mlnx1/libibverbs.md","./usr/share/doc/librdmacm-54mlnx1","./usr/share/doc/librdmacm-54mlnx1/librdmacm.md","./usr/share/doc/libvma-9.3.1","./usr/share/doc/libvma-9.3.1/CHANGES","./usr/share/doc/libvma-9.3.1/README","./usr/share/doc/mlnx-tools-5.2.0","./usr/share/doc/mlnx-tools-5.2.0/ib2ib_setup.txt","./usr/share/doc/rdma-core-54mlnx1","./usr/share/doc/rdma-core-54mlnx1/COPYING.BSD_FB","./usr/share/doc/rdma-core-54mlnx1/COPYING.BSD_MIT","./usr/share/doc/rdma-core-54mlnx1/COPYING.GPL2","./usr/share/doc/rdma-core-54mlnx1/COPYING.md","./usr/share/doc/rdma-core-54mlnx1/README.md","./usr/share/doc/rdma-core-54mlnx1/tag_matching.md","./usr/share/doc/rdma-core-54mlnx1/udev.md","./usr/share/licenses/dpcp-1.1.12","./usr/share/licenses/dpcp-1.1.12/LICENSE","./usr/share/licenses/libvma-9.3.1","./usr/share/licenses/libvma-9.3.1/COPYING","./usr/share/man/man7/rsocket.7.gz","./usr/share/man/man7/vma.7.gz","./usr/share/man/man8/ib2ib_setup.8.gz","./usr/share/man/man8/rdma-ndd.8.gz","./usr/share/man/man8/vmad.8.gz","./usr/share/mlnx_ofed/mlnx_bf_assign_ct_cores.sh","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml","./usr/lib/python2.7/site-packages/dcbnetlink.pyc","./usr/lib/python2.7/site-packages/dcbnetlink.pyo","./usr/lib/python2.7/site-packages/genetlink.pyc","./usr/lib/python2.7/site-packages/genetlink.pyo","./usr/lib/python2.7/site-packages/netlink.pyc","./usr/lib/python2.7/site-packages/netlink.pyo"],"md5sum":"4e8c02da89ad6cc42a86ce7a425a9a10","name":"mlnx-ofa_kernel-5.4-OFED.5.4.1.0.3.1.rhel7u8.x86_64.rpm","release":"2021-07-13T06:45:06","revision":"0","sha1sum":"f6a94b540112f74ca230dd2ef6c7df6cb26de6f5","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81"],"type_of_change":"1","version":"5.4"},{"bytes":"1334346","datemodified":"2021-07-13T07:58:16","file_list":["./etc/depmod.d/zz01-mlnx-ofa_kernel-auxiliary.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-bnxt_re.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-efa.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-hfi1.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-i40iw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ipath.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ipoib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_iser.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_isert.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_mthca.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_qib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srp.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srpt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_umad.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_uverbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cxgb3.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cxgb4.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_nes.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx_compat.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxfw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvme-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvmet-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ocrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-opa_vnic.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-qedr.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_rxe.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdmavt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rpcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-svcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-usnic_verbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-vmw_pvrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-xprtrdma.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/compat","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/compat/mlx_compat.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/base","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/base/auxiliary.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_cm.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_core.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_ucm.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_umad.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/iw_cm.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_cm.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb3","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb3/iw_cxgb3.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa/efa.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/i40iw","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ipath","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ipath/ib_ipath.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mthca","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mthca/ib_mthca.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/nes","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/nes/iw_nes.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ocrdma","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ocrdma/ocrdma.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qib","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qib/ib_qib.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host/nvme-rdma.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/net","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/kmod-mlnx-ofa_kernel/component.xml"],"md5sum":"31f12a12153722bb83643729217efc27","name":"kmod-mlnx-ofa_kernel-5.4-OFED.5.4.1.0.3.1.rhel7u8.x86_64.rpm","release":"2021-07-13T06:45:06","revision":"0","sha1sum":"c94df784f3ae072d0fb792f4e862d94ebc1345fe","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81"],"type_of_change":"1","version":"5.4"}],"id":{"product":"63a0b4d1fd5143328925661934c3ed2a","version":"725f3d3289f146fca2087f4191c3cb0a"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)","OSVersion":{"name":"Linux","value":"6.9"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)","OSVersion":{"name":"Linux","value":"6.10"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)","OSVersion":{"name":"Linux","value":"7.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)","OSVersion":{"name":"Linux","value":"7.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-5.4&quot;&nbsp;RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.&nbsp;<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using kernel version 3.10.0-1127.el7&nbsp;or any future errata:<br />\n<br />\n<strong># rpm -Uvh&nbsp;kmod-mlnx-ofa_kernel-5.4-OFED.5.4-0.5.1.1.rhel7u8.x86_64.rpm mlnx-ofa_kernel-5.4-OFED.5.4-0.5.1.1.rhel7u8.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 Adapters for Red Hat Enterprise Linux 7 Update 8 (x86_64)"},{"lang":"ja","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) ドライバーfor Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 Adapters for Red Hat Enterprise Linux 7 Update 8 (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"101f","subdev":"0012","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30012","type":"pci","ven":"15b3"},{"dev":"101f","subdev":"0007","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30007","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"032D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-10171590032d","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T17:11:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Changes and new features in HPE Mellanox RoCE driver&nbsp;version 5.2:</strong></p>\n\n<p><strong>For ConnectX-5 Adapters and above:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>CQE compression support for Rx multi-strides packets.</li>\n\t\t<li>Configuring QoS on a single QP or on a group of QPs.</li>\n\t\t<li>Encap/decap hardware offload of IPv4 traffic over MPLS-over-UDP. This can be used in networks with MPLS routers to achieve more efficient routing.</li>\n\t\t<li>Connection tracking rules on VFs to forward traffic from one VF to the other.</li>\n\t\t<li>Offloading sFlow sampling rules.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For ConnectX-5 Adapters and ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>A locking mechanism to enable parallel insertion of rules into the software steering using the mlx5dv_dr API. The parallel insertion improves the insertion rate and takes place when adding Rx and Tx rules via the FDB domain.</li>\n\t\t<li>Option to match mlx5dv_dr API on Geneve tunnel using a dynamic flex parser. The option header consists of class, type, length and data. The parser should be configured using devx command, after which a rule can be created to match on parser ID and data.</li>\n\t\t<li>Geneve tunneling offload, including matching on extension header.</li>\n\t\t<li>Parallel insertion and deletion of offloaded rules using multiple&nbsp;OVS threads.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>[Beta] Modify GTP-U TEID. This support requires flex parser&nbsp;configuration.</li>\n\t\t<li>[Beta] Improved performance of OVS Connection Tracking flows by&nbsp;enabling the merge of the multi-table flow matches and actions into one joint flow.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Dx Adapters and above:</strong></p>\n\n<p>Added support for the following features:</p>\n\n<ul>\n\t<li>Transmitted packet timestamping accuracy can be improved when using a timestamp generated at the port level instead of a timestamp generated upon CQE creation. Tx port time-stamping better reflects the actual time of a packet&#39;s transmission. This feature is disabled by default. The feature can be enabled or disabled using the following command. ethtool --set-priv-flags tx_port_ts on / off.</li>\n\t<li>Offloading tunnel rules when the source interface is VF (in addition to uplink) in the Hypervisor.</li>\n\t<li>Using Mirroring Offload with Connection Tracking.</li>\n\t<li>ASO flow meter using the mlx5dv_dr API, which allows for monitoring the packet rate for specific flows. When a packet hits a flow that is connected to a flow meter, the rate of packets through this meter is evaluated, and the packet is marked with a color copied into one of the C registers, according to the current rate compared to the reference rate.</li>\n\t<li>ASO first hit using the mlx5dv_dr API, which allows for tracking rule hits by packets. When a packet hits a rule with the ASO first hit action, a flag is set indicating this event, and the original value of the flag is copied to one of the C registers.</li>\n\t<li>mlx5dv_dr API support for matching on a new field &quot;gtpu_first_ext_dw_0&quot;. This field enables packet filtering based on the GTP-U first extension header (first dword only). To enable parsing of tunnel GTP-U extension header, run the following command. ./cloud_fw_reset.py FLEX_PARSER_PROFILE_ENABLE=3.</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Lx Adapters and above:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>IPsec full offload support for extended sequence number, replay protection window and lifetime packet limit.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;All HCA&#39;s:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>New query GID API that allows for querying a single GID entry by its port and GID index, or querying for all GID tables of a specific device. This API works over ioctl instead of sysfs, which accelerates the querying process.</li>\n\t\t<li>Performing multi-host firmware reset in order to upgrade the device firmware. Firmware reset loads the new firmware in case it was burnt on the flash and was pending activation, and reload.</li>\n\t\t<li>[Alpha] Firmware live patching in the driver. Live patching updates the firmware without the need to perform firmware reset. However, it can only be applied in scenarios where the difference between the current and new firmware versions are minor, which is decided upon by the firmware itself.</li>\n\t\t<li>devlink tool for performing firmware reset in order to upgrade the device firmware. Firmware reset loads the new firmware in case it was burnt on the flash and was pending activation, and reloads the current firmware image from the flash in case no new firmware was pending. For further information, please refer to the the devlink man page.</li>\n\t\t<li>A resiliency mechanism for the driver to manually poll the command event queue (EQ) in case of a command timeout. In case the resiliency mechanism finds unhandled event queue entry (EQE) due to a lost interrupt, the driver will handle it, after which the command interface returns to a healthy state.</li>\n\t\t<li>Setting a sniffer private flag is deprecated and no longer required. In order to capture offloaded/RoCE traffic, tcpdump can now be run on the RDMA device.</li>\n\t\t<li>Added per-port reporters to devlink health to manage per-port health activities. Users can now access the devlink port reporters by specifying the port index in addition to the device devlink name through the devlink health commands API. This update was first introduced in iproute2 v5.8. As part of this feature, mlx5e Tx and Rx reporters are now redefined as devlink port reporters. For examples, please see devlink-health manpage</li>\n\t\t<li>Optimized memory consumption of memory registration in huge page systems. As an example, in a 2MB huge page system, 600 MB would be saved for 100 GB memory registration.</li>\n\t\t<li>mlx5dv API to modify the configured UDP source port for RoCE packets of a given RC/UC QP when QP is in RTS state.</li>\n\t\t<li>Accelerating Tx datapath by saving PCI bandwidth and CPU utilization. The savings are achieved by aggregating multiple packets into a single WQE. The feature is driven by xmit_more for certain traffic types, such as UDP.</li>\n\t</ul>\n\t</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 5.2:</strong></p>\n\n<ul>\n\t<li>Clearing min_rate on all SR-IOV legacy VFs after setting min_rate to at least one of the VFs did not disable QoS min_rate.</li>\n\t<li>An empty /usr/src/mlnx-ofa_kernel/default is now no longer created.</li>\n\t<li>An issue where installing packages through a repository failed after generation of metapackages using --add-kernel-support. The failure occurred due to excessive and incorrect Obsolete headers in those metapackages.Enabled installation of mlnx-ofa_kernel package to /bin/python3 instead of / usr/bin/python3 on RHEL 8.x systems.</li>\n\t<li>All IPoIB offload packets were wrongly counted as rx_csum_complete. These packets are now identified as rx_csum_unnecessary packets.</li>\n\t<li>mlx5dv_dr_rule_destroy segmentation fault could happen in rare cases with multiple rules on the same matcher with a different number of actions. This could happen after reusing an already deleted rule memory with less actions.</li>\n\t<li>An issue of moving to SwitchDev mode after configuring DSCP (Differentiated Service Code Point).</li>\n\t<li>Global traffic class configuration did not take effect on DC QPs (Dynamically Connected Queue Pairs).</li>\n\t<li>ib_send_bw traffic frequently dropped to zero when RDMA CM was used, because of incorrect&nbsp;min_rnr_timer setting on the responder side. The min_rnr_timer setting is now aligned with the setting in non-RDMA CM cases.</li>\n\t<li>Traffic did not pass over VFs with VST QinQ feature is enabled.</li>\n\t<li>When traffic was sent over Geneve VLAN with Tx VLAN offload enabled and TSO (TCP Segmentation Offload)&nbsp;or Tx csum enabled, traffic could be dropped and not sent to the wire.</li>\n\t<li>An issue that caused the firmware to restart upon installing mlnxofed-dpdk-upstream-libs package manually.</li>\n\t<li>Bad utility paths in rdma-core &quot;dracut&quot; hooks on SLES systems, which used to result in the following errors when running &quot;dracut&quot; with the &quot;--add rdma&quot; option. dracut-install:\n\t<ul>\n\t\t<li>ERROR: installing &lsquo;/usr/libexec/mlx4-setup.sh&rsquo; dracut: /usr/lib/dracut/dracut-install -D /var/tmp/dracut.UdCOSJ/ initramfs /usr/libexec/mlx4-setup.sh dracut-install: ERROR: installing &lsquo;/usr/libexec/rdma-set-sriov-vf&rsquo; dracut: /usr/lib/dracut/dracut-install -D /var/tmp/dracut.UdCOSJ/ initramfs /usr/libexec/rdma-set-sriov-vf</li>\n\t</ul>\n\t</li>\n\t<li>Traffic class value was not updated in DCT when set via sysfs.</li>\n\t<li>A doorbell loss issue on AMD platforms with Secure Memory Encryption (SME).</li>\n\t<li>Registering memory using mlx5dv_devx_umem_reg while forking. Without this fix, applications which use fork() or similar syscalls while using a memory registered with umem_reg could hang due to incorrect physical page mapping. This fix requires setting the IBV_FORK_SAFE environment variable.</li>\n\t<li>When&nbsp;unbinding the device resulted in the following message being printed to the dmesg: &quot;failed to disable DC tracer&quot;</li>\n\t<li>Content of file /sys/class/net//statistics/ multicast might have been out of date and might have displayed values lower than the real values.</li>\n\t<li>ERSPAN (Encapsulated Remote SPAN) protocol was available only when turning off Tx checksum offload.</li>\n\t<li>A udev script issue which caused non-mellanox devices to be renamed.</li>\n\t<li>Missing representor statistics when using ifconfig.</li>\n\t<li>Fixed wrong value of skb mark of received packets on representors.</li>\n\t<li>An issue which caused second port representors to be named as first port representors.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Changes and new features in HPE Mellanox RoCE driver&nbsp;version 5.3:</strong></p>\n\n<p><strong>For ConnectX-5 Adapters and above:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>CQE compression support for Rx multi-strides packets.</li>\n\t\t<li>Configuring QoS on a single QP or on a group of QPs.</li>\n\t\t<li>Encap/decap hardware offload of IPv4 traffic over MPLS-over-UDP. This can be used in networks with MPLS routers to achieve more efficient routing.</li>\n\t\t<li>Connection tracking rules on VFs to forward traffic from one VF to the other.</li>\n\t\t<li>Offloading sFlow sampling rules.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For ConnectX-5 Adapters and ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>A locking mechanism to enable parallel insertion of rules into the software steering using the mlx5dv_dr API. The parallel insertion improves the insertion rate and takes place when adding Rx and Tx rules via the FDB domain.</li>\n\t\t<li>Option to match mlx5dv_dr API on Geneve tunnel using a dynamic flex parser. The option header consists of class, type, length and data. The parser should be configured using devx command, after which a rule can be created to match on parser ID and data.</li>\n\t\t<li>Geneve tunneling offload, including matching on extension header.</li>\n\t\t<li>Parallel insertion and deletion of offloaded rules using multiple&nbsp;OVS threads.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>[Beta] Modify GTP-U TEID. This support requires flex parser&nbsp;configuration.</li>\n\t\t<li>[Beta] Improved performance of OVS Connection Tracking flows by&nbsp;enabling the merge of the multi-table flow matches and actions into one joint flow.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Dx Adapters and above:</strong></p>\n\n<p>Added support for the following features:</p>\n\n<ul>\n\t<li>Transmitted packet timestamping accuracy can be improved when using a timestamp generated at the port level instead of a timestamp generated upon CQE creation. Tx port time-stamping better reflects the actual time of a packet&#39;s transmission. This feature is disabled by default. The feature can be enabled or disabled using the following command. ethtool --set-priv-flags tx_port_ts on / off.</li>\n\t<li>Offloading tunnel rules when the source interface is VF (in addition to uplink) in the Hypervisor.</li>\n\t<li>Using Mirroring Offload with Connection Tracking.</li>\n\t<li>ASO flow meter using the mlx5dv_dr API, which allows for monitoring the packet rate for specific flows. When a packet hits a flow that is connected to a flow meter, the rate of packets through this meter is evaluated, and the packet is marked with a color copied into one of the C registers, according to the current rate compared to the reference rate.</li>\n\t<li>ASO first hit using the mlx5dv_dr API, which allows for tracking rule hits by packets. When a packet hits a rule with the ASO first hit action, a flag is set indicating this event, and the original value of the flag is copied to one of the C registers.</li>\n\t<li>mlx5dv_dr API support for matching on a new field &quot;gtpu_first_ext_dw_0&quot;. This field enables packet filtering based on the GTP-U first extension header (first dword only). To enable parsing of tunnel GTP-U extension header, run the following command. ./cloud_fw_reset.py FLEX_PARSER_PROFILE_ENABLE=3.</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Lx Adapters and above:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>IPsec full offload support for extended sequence number, replay protection window and lifetime packet limit.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;All HCA&#39;s:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>New query GID API that allows for querying a single GID entry by its port and GID index, or querying for all GID tables of a specific device. This API works over ioctl instead of sysfs, which accelerates the querying process.</li>\n\t\t<li>Performing multi-host firmware reset in order to upgrade the device firmware. Firmware reset loads the new firmware in case it was burnt on the flash and was pending activation, and reload.</li>\n\t\t<li>[Alpha] Firmware live patching in the driver. Live patching updates the firmware without the need to perform firmware reset. However, it can only be applied in scenarios where the difference between the current and new firmware versions are minor, which is decided upon by the firmware itself.</li>\n\t\t<li>devlink tool for performing firmware reset in order to upgrade the device firmware. Firmware reset loads the new firmware in case it was burnt on the flash and was pending activation, and reloads the current firmware image from the flash in case no new firmware was pending. For further information, please refer to the the devlink man page.</li>\n\t\t<li>A resiliency mechanism for the driver to manually poll the command event queue (EQ) in case of a command timeout. In case the resiliency mechanism finds unhandled event queue entry (EQE) due to a lost interrupt, the driver will handle it, after which the command interface returns to a healthy state.</li>\n\t\t<li>Setting a sniffer private flag is deprecated and no longer required. In order to capture offloaded/RoCE traffic, tcpdump can now be run on the RDMA device.</li>\n\t\t<li>Added per-port reporters to devlink health to manage per-port health activities. Users can now access the devlink port reporters by specifying the port index in addition to the device devlink name through the devlink health commands API. This update was first introduced in iproute2 v5.8. As part of this feature, mlx5e Tx and Rx reporters are now redefined as devlink port reporters. For examples, please see devlink-health manpage</li>\n\t\t<li>Optimized memory consumption of memory registration in huge page systems. As an example, in a 2MB huge page system, 600 MB would be saved for 100 GB memory registration.</li>\n\t\t<li>mlx5dv API to modify the configured UDP source port for RoCE packets of a given RC/UC QP when QP is in RTS state.</li>\n\t\t<li>Accelerating Tx datapath by saving PCI bandwidth and CPU utilization. The savings are achieved by aggregating multiple packets into a single WQE. The feature is driven by xmit_more for certain traffic types, such as UDP.</li>\n\t</ul>\n\t</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 5.3:</strong></p>\n\n<ul>\n\t<li>Clearing min_rate on all SR-IOV legacy VFs after setting min_rate to at least one of the VFs did not disable QoS min_rate.</li>\n\t<li>An empty /usr/src/mlnx-ofa_kernel/default is now no longer created.</li>\n\t<li>An issue where installing packages through a repository failed after generation of metapackages using --add-kernel-support. The failure occurred due to excessive and incorrect Obsolete headers in those metapackages.Enabled installation of mlnx-ofa_kernel package to /bin/python3 instead of / usr/bin/python3 on RHEL 8.x systems.</li>\n\t<li>All IPoIB offload packets were wrongly counted as rx_csum_complete. These packets are now identified as rx_csum_unnecessary packets.</li>\n\t<li>mlx5dv_dr_rule_destroy segmentation fault could happen in rare cases with multiple rules on the same matcher with a different number of actions. This could happen after reusing an already deleted rule memory with less actions.</li>\n\t<li>An issue of moving to SwitchDev mode after configuring DSCP (Differentiated Service Code Point).</li>\n\t<li>Global traffic class configuration did not take effect on DC QPs (Dynamically Connected Queue Pairs).</li>\n\t<li>ib_send_bw traffic frequently dropped to zero when RDMA CM was used, because of incorrect&nbsp;min_rnr_timer setting on the responder side. The min_rnr_timer setting is now aligned with the setting in non-RDMA CM cases.</li>\n\t<li>Traffic did not pass over VFs with VST QinQ feature is enabled.</li>\n\t<li>When traffic was sent over Geneve VLAN with Tx VLAN offload enabled and TSO (TCP Segmentation Offload)&nbsp;or Tx csum enabled, traffic could be dropped and not sent to the wire.</li>\n\t<li>An issue that caused the firmware to restart upon installing mlnxofed-dpdk-upstream-libs package manually.</li>\n\t<li>Bad utility paths in rdma-core &quot;dracut&quot; hooks on SLES systems, which used to result in the following errors when running &quot;dracut&quot; with the &quot;--add rdma&quot; option. dracut-install:\n\t<ul>\n\t\t<li>ERROR: installing &lsquo;/usr/libexec/mlx4-setup.sh&rsquo; dracut: /usr/lib/dracut/dracut-install -D /var/tmp/dracut.UdCOSJ/ initramfs /usr/libexec/mlx4-setup.sh dracut-install: ERROR: installing &lsquo;/usr/libexec/rdma-set-sriov-vf&rsquo; dracut: /usr/lib/dracut/dracut-install -D /var/tmp/dracut.UdCOSJ/ initramfs /usr/libexec/rdma-set-sriov-vf</li>\n\t</ul>\n\t</li>\n\t<li>Traffic class value was not updated in DCT when set via sysfs.</li>\n\t<li>A doorbell loss issue on AMD platforms with Secure Memory Encryption (SME).</li>\n\t<li>Registering memory using mlx5dv_devx_umem_reg while forking. Without this fix, applications which use fork() or similar syscalls while using a memory registered with umem_reg could hang due to incorrect physical page mapping. This fix requires setting the IBV_FORK_SAFE environment variable.</li>\n\t<li>When&nbsp;unbinding the device resulted in the following message being printed to the dmesg: &quot;failed to disable DC tracer&quot;</li>\n\t<li>Content of file /sys/class/net//statistics/ multicast might have been out of date and might have displayed values lower than the real values.</li>\n\t<li>ERSPAN (Encapsulated Remote SPAN) protocol was available only when turning off Tx checksum offload.</li>\n\t<li>A udev script issue which caused non-mellanox devices to be renamed.</li>\n\t<li>Missing representor statistics when using ifconfig.</li>\n\t<li>Fixed wrong value of skb mark of received packets on representors.</li>\n\t<li>An issue which caused second port representors to be named as first port representors.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"kmod-mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"kmod-mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900374","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the boot BIOS and firmware of QLogic Fibre Channel host bus adapters. "}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"3785720","datemodified":"2021-08-27T03:54:47","file_list":["Q25A0382.BIN","QLAFWUpdate.exe","adapters.properties","bk017507.bin","cp048728.xml","cpqsetup.exe","hld60404.bin","installer.dll","payload.json","qlafwupdate.properties","qlafwupdate.txt","qlsdm.dll","reference.xml","runquery.bat","x103Cx1939/BC26xx.DAT","x103Cx1939/FWA83xxB.DAT","x1590x00F9/PEP27BC.dat","x1590x00F9/Q27FBC.dat","x1590x00F9/Q27FWA.dat","x1590x00FA/PEP27BC.dat","x1590x00FA/Q27FBC.dat","x1590x00FA/Q27FWA.dat","x1590x0203/PEP27BC.dat","x1590x0203/Q27FBC.dat","x1590x0203/Q27FWA.dat","x1590x0204/PEP27BC.dat","x1590x0204/Q27FBC.dat","x1590x0204/Q27FWA.dat","x1590x022D/PEP27BC.dat","x1590x022D/Q27FBC.dat","x1590x022D/Q27FWA.dat"],"md5sum":"6e22152bbac898a85bbe59506dc81025","name":"cp048728.exe","release":"2021-08-27T03:39:50","revision":"0","sha1sum":"f8dce95a8f4709287c0d7e2c838843d212e77486","size":"3MB","target_guids":[],"type_of_change":"1","version":"2021.10.01"}],"id":{"product":"af966b72e2104d409bcc8434bd75a78d","version":"9ffc0d561b3a4980baf2be2a01b03e8d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component number.<br />\n<br />\nFrom that drive and directory, execute the downloaded file.<br />\n<br />\nClick the &quot;Install&quot; button to proceed with the installation.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for QLogic Fibre Channel Host Bus Adapters - Microsoft Windows Server 2012R2/2016/2019(x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-18T06:47:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Speed</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">MBI</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Firmware</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">UEFI</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Boot Bios</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE 81Q 8Gb PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.82.00</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8.08.207</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.00</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.56</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE 82Q 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.82.00</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8.08.207</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.00</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.56</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE 84Q 8Gb Quad Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.82.00</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8.08.207</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.00</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.56</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1000Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">6.04.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8.08.232</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.43</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1000Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">6.04.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8.08.232</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.43</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">1.75.07</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">9.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.64</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">1.75.07</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">9.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.64</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">1.75.07</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">9.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.64</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">1.75.07</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">9.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.64</p>\n\t\t\t</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"qlogic","sw_key_expectedpath":"firmware:qlogic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900213","languages":[{"lang":"fr","x_late":"Micrologiciel - Lights-Out Management"},{"lang":"en","x_late":"Firmware - Lights-Out Management"},{"lang":"cn","x_late":"固件 - Lights-Out Management"},{"lang":"tw","x_late":"韌體 ─ Lights─Out 管理"},{"lang":"de","x_late":"Firmware - LOM (Lights-Out Management)"},{"lang":"ko","x_late":"펌웨어 - Lights-Out 관리"},{"lang":"ja","x_late":"ファームウェア - Lights-Outマネジメント"},{"lang":"es","x_late":"Firmware - Administración de apagado eléctrico"}]}],"description":[{"lang":"en","x_late":"This component provides updated iLO firmware that can be installed directly on supported VMware ESXi Operating Systems. Use this component with HPE Smart Update Manager to update supported HPE ProLiant Gen8 and Gen9, HPE Apollo Gen9, and HPE Synergy 480 Gen9 systems. Click the “Installation Instructions” tab to review important firmware update details."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるVMware ESXiオペレーティングシステムに直接インストール可能なアップデートされたiLOファームウェアを提供します。このコンポーネントをHPE Smart Update Managerとともに使用して、サポートされているHPE ProLiant Gen8およびGen9、HPE Apollo Gen9、およびHPE Synergy 480 Gen9システムをアップデートします。[インストール手順]タブをクリックして、重要なファームウェアアップデートの詳細を確認します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[{"lang":"en","x_late":"<p>&nbsp;</p>\n\n<p>iLO&nbsp;4 User Guide and Lights-Out Scripting Guide can also be found by following the links at:<br />\n<br />\n<a href=\"http://www.hpe.com/info/ilo\">http://www.hpe.com/info/ilo</a><br />\n<br />\nSelect your lights-out product, then support &amp; documents, then manuals.<br />\n&nbsp;</p>\n\n<ul>\n\t<li>Check the online help for additional information about how to use features.&nbsp;<br />\n\tOnline help can be accessed from within the browser web pages by clicking the question mark in the upper right-hand corner of each page.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p> </p>\n\n<p>iLO 4ユーザーガイドおよびLights-Outスクリプティングガイドは、以下のリンクから入手可能です。<br />\n<br />\n<a href=\"http://www.hpe.com/info/ilo\">http://www.hpe.com/info/ilo</a><br />\n<br />\nご使用のLights-Out製品、サポートドキュメント、ドキュメントの順に選択します。<br />\n </p>\n\n<ul>\n\t<li>この機能の使用方法について詳しくは、オンラインヘルプを参照してください。 <br />\n\tオンラインヘルプは、各ページの右上隅のクエスチョンマークをクリックすると、ブラウザーからアクセスできます。</li>\n</ul>\n"}],"files":[{"bytes":"15508049","datemodified":"2021-04-28T10:49:37","file_list":["/CP046464.vmexe","/CP046464.vmexe64","/CP046464.vmfile","/CP046464.xml","/README.txt"],"md5sum":"59401fff411cb17cb8f086f2a9784467","name":"CP046464.zip","release":"2021-05-07T00:00:00","revision":"1","sha1sum":"3d3dc39648e925852901ba2796db0f7560295ff2","size":"14MB","target_guids":[],"type_of_change":"2","version":"2.78","vib_list":[]}],"id":{"product":"866094c6d7794cccb749f7742eb5d7bc","version":"bbce647f76d946c0b6e773ad2a63a7a3"},"installation":{"command":"sh CP0XXXXX.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 3/4 Channel Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 3/4 Channel Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"}]},{"ListConditional":"OR","Requirement":[]}]}]},"installation_notes":[{"lang":"en","x_late":"<h2><strong>For supported HPE Synergy 480 Gen9 Systems:</strong></h2>\n\n<p>This firmware release is fully supported when applied as a hotfix to the following HPE Synergy Software Releases:&nbsp;</p>\n\n<ul>\n\t<li>All HPE OneView versions 5.4&nbsp;and later in combination with HPE Synergy Custom SPP 2020.07, and HPE Synergy Custom SPP 2021.01</li>\n\t<li>All HPE OneView versions 5.6 and later in combination with HPE Synergy Custom SPP 2021.02</li>\n</ul>\n\n<p>For Synergy Hotfix installation instructions see HPE iLO User guide [https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=c03334051] sections titled:&nbsp;</p>\n\n<ul>\n\t<li>Adding hotfixes to create an HPE OneView custom firmware bundle</li>\n\t<li>Using HPE Smart Update Manager to create a custom ISO on Windows</li>\n</ul>\n\n<h2><strong>For supported HPE ProLiant Gen8, ProLiant Gen9, Apollo 4200 Gen9, and Apollo 4350 Gen9 Systems: </strong></h2>\n\n<h3>To use HPE Smart Update Manager from the HPE Service Pack for ProLiant:<br />\nNote:&nbsp;The iLO 4 firmware update does not require a server reboot; however, if VMware ESXi is booting from an SD card, a reboot is required.</h3>\n\n<ul>\n\t<li>Offline:\n\t<ul>\n\t\t<li>Place the&nbsp;<a href=\"http://h17007.www1.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">HPE Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_357c87ee9b054ad7a631d9eaba\">HPE USB Key Creator Utility</a>.</li>\n\t\t<li>Place the desired firmware to be updated in the directory, /hp/swpackages on the USB key.</li>\n\t\t<li>Boot from the newly created HPE Service Pack for Proliant USB key.</li>\n\t\t<li>Follow HP Smart Update Manager steps to complete firmware update.</li>\n\t</ul>\n\t</li>\n\t<li>Remote Online:\n\t<ul>\n\t\t<li>Place the SPP on a USB key using the&nbsp;<a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_357c87ee9b054ad7a631d9eaba\">HPE USB Key Creator Utility</a>.</li>\n\t\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/hpe/swpackages on the USB key.</li>\n\t\t<li>Mount the USB key on a remote server running Windows or Linux</li>\n\t\t<li>CD /hpe/swpackages and ./hpsum</li>\n\t\t<li>Select the next button</li>\n\t\t<li>Click Add Single Target</li>\n\t\t<li>Type the IP or DNS address of the ESXi host to be updated</li>\n\t\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t\t<li>Follow HPE Smart Update Manager Steps and complete the firmware update.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<h3>To use HPE Insight Control for vCenter :</h3>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<h3>To update firmware from VMware ESXi operating system on target server:</h3>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Unzip&nbsp;the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe is executable by using the command:\n\t<ul>\n\t\t<li>chmod +x CPXXXXXX.vmexe</li>\n\t</ul>\n\t</li>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n</ul>\n"},{"lang":"ja","x_late":"<h2><strong>サポートされているHPE Synergy 480 Gen9システムの場合：</strong></h2>\n\n<p>このファームウェアリリースは、次のHPE Synergyソフトウェアリリースのホットフィックスとして適用されると完全にサポートされます。 </p>\n\n<ul>\n\t<li>HPE OneViewバージョン5.4以降のすべてと、HPE SynergyカスタムSPP 2020.07およびHPE SynergyカスタムSPP 2021.01の組み合わせ</li>\n\t<li>HPE OneViewバージョン5.6以降のすべてと、HPE SynergyカスタムSPP 2021.02の組み合わせ</li>\n</ul>\n\n<p>Synergyホットフィックスのインストール手順については、HPE iLOユーザーガイド[https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&docId=c03334051]で次のタイトルのセクションを参照してください。 </p>\n\n<ul>\n\t<li>Adding hotfixes to create an HPE OneView custom firmware bundle</li>\n\t<li>Using HPE Smart Update Manager to create a custom ISO on Windows</li>\n</ul>\n\n<h2><strong>サポートされているHPE ProLiant Gen8、ProLiant Gen9、Apollo 4200 Gen9、およびApollo 4350 Gen9システムの場合：</strong></h2>\n\n<h3>HPE Smart Update Managerを使用するには、HPE Service Pack for ProLiantから以下の手順に従ってください。<br />\n注記: iLO 4ファームウェアのアップデートではサーバーのリブートが不要です。ただし、VMware ESXiをSDカードから起動する場合は、リブートが必要です。</h3>\n\n<ul>\n\t<li>オフライン:\n\t<ul>\n\t\t<li><a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_357c87ee9b054ad7a631d9eaba\">HPE USB Key Creator Utility</a>を使用して<a href=\"http://h17007.www1.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">HPE Service Pack for ProLiant</a>をUSBキーにコピーします。</li>\n\t\t<li>アップデートするファームウェアをUSBキーの/hp/swpackagesディレクトリにコピーします。</li>\n\t\t<li>新たに作成したHPE Service Pack for ProLiant USBキーから起動します。</li>\n\t\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n\t</ul>\n\t</li>\n\t<li>リモートオンライン:\n\t<ul>\n\t\t<li><a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_357c87ee9b054ad7a631d9eaba\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t\t<li>アップデートするファームウェアをUSBキーの/SPP20xxxxx/hpe/swpackagesディレクトリにコピーします。</li>\n\t\t<li>WindowsまたはLinuxを実行するリモートサーバーにUSBキーをマウントします。</li>\n\t\t<li>CD /hpe/swpackagesおよび./hpsum</li>\n\t\t<li>次へボタンを選択します。</li>\n\t\t<li>シングルターゲットの追加をクリックします。</li>\n\t\t<li>アップデートされるESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t\t<li>HPE Smart Update Managerの手順に従って、ファームウェアのアップデートを完了します。</li>\n\t</ul>\n\t</li>\n</ul>\n\n<h3>HPE Insight Control for vCenterを使用するには、以下の手順に従ってください:</h3>\n\n<ul>\n\t<li>vSphereクライアントにログインします。</li>\n\t<li>インベントリツリーのサーバーまたはクラスターを選択します。</li>\n\t<li>HPE Insight Managementタブをクリックします。</li>\n\t<li>HP Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</li>\n</ul>\n\n<h3>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</h3>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします</li>\n\t<li>コマンドを使用してCPXXXXXX.vmexeが実行可能であることを確認します:\n\t<ul>\n\t\t<li>chmod +x CPXXXXXX.vmexe</li>\n\t</ul>\n\t</li>\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPXXXXXX.vmexe</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware ESXi  - HPE Integrated Lights-Out 4"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for VMware ESXi -HPE Integrated Lights-Out 4"}],"prerequisites":{"required_diskspace":{"size_kb":"5120"},"supported_devices":[{"id":"5219994","target_guid":"","type":"other"},{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3308","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3300","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3301","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3302","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T12:36:30","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>&nbsp;-&nbsp; Updated Jquery library to 3.5.1<br />\n&nbsp;-&nbsp; Updated Openssl library to OpenSSL 1.0.2x<br />\n&nbsp;-&nbsp; eRS enhanced to support generic service event 1000 for critical events<br />\n&nbsp;</p>\n","latest_fixes_x_late":"<p>- IML reports fan modules failed for D3000 only after server reboot<br />\n&nbsp;&nbsp; &nbsp;- eRS service event added for Critical events like System Power Fault Detection<br />\n&nbsp;&nbsp; &nbsp;- Security fixes<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; - Added a Content Security Policy( CSP) to harden the web interfaces<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; - Enhanced Input validation for user controlled data</p>\n\n<p>- Fixes for multiple security vulnerabilities</p>\n"},{"curr_enhancements_x_late":"<p>&nbsp;-&nbsp; Updated Jquery library to 3.5.1<br />\n&nbsp;-&nbsp; Updated Openssl library to OpenSSL 1.0.2x<br />\n&nbsp;-&nbsp; eRS enhanced to support generic service event 1000 for critical events<br />\n&nbsp;</p>\n","curr_fixes_x_late":"<p>- IML reports fan modules failed for D3000 only after server reboot<br />\n&nbsp;&nbsp; &nbsp;- eRS service event added for Critical events like System Power Fault Detection<br />\n&nbsp;&nbsp; &nbsp;- Security fixes<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; - Added a Content Security Policy( CSP) to harden the web interfaces<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; - Enhanced Input validation for user controlled data</p>\n\n<p>- Fixes for multiple security vulnerabilities</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"P94","value":"HP ProLiant XL220a Gen8 v2 Server"},{"key":"J06","value":"HP ProLiant MicroServer Gen8"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P74","value":"HP ProLiant SL140s Gen8 Server (private)"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P98","value":"HP ProLiant SL220f Gen8 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"Carbondale14","value":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A29","value":"HP ProLiant DL585 Gen8 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 SE Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P78","value":"HP ProLiant ML310e Gen8 v2 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"P83","value":"HP ProLiant SL210t Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P94","value":"HP ProLiant SL241n Gen8 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"P91","value":"HP ProLiant SL240n Gen8 Server - cancelled"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P93","value":"HP ProLiant SL240d Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 SE Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"}],"sw_keys":[{"name":"RI10","sw_key_expectedpath":"firmware:ilo4"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HP Ethernet 10Gb 2-port 560FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":60,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-10F8103C18D0","Version":"1.2836.0"},{"DeviceName":"HP Ethernet 10Gb 2-port 560M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":60,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-10F8103C17D2","Version":"1.2836.0"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Blade Intel Ethernet NICs ROM images running under Linux x86_64 platform."},{"lang":"ja","x_late":"このパッケージには、Linux x86_64プラットフォームで動作するHPE Blade Intel Ethernet NIC ROMイメージをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p>\n\n<table border=\"1\">\n\t<thead>\n\t\t<tr>\n\t\t\t<th>NIC</th>\n\t\t\t<th>EEPROM/NVM Version</th>\n\t\t\t<th>OROM Version</th>\n\t\t</tr>\n\t</thead>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 560FLB Adapter</td>\n\t\t\t<td>800008F0</td>\n\t\t\t<td>1.2836.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 560M Adapter</td>\n\t\t\t<td>8000083D</td>\n\t\t\t<td>1.2836.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>The combo image v1.2836.0 includes: Boot Agent: 1GbE - v1.5.88, 10GbE - v2.4.44, 40GbE - v1.1.18&nbsp;&amp; UEFI Drivers: 1GbE - v9.4.06, 10GbE - v7.8.13, 40GbE - v4.4.12</p>\n"},{"lang":"ja","x_late":"<p>このソフトウェアパッケージは、以下にリストされるサポートされるネットワークアダプターの次のファームウェアのバージョンを含みます：</p>\n\n<table border=\"1\">\n\t<thead>\n\t\t<tr>\n\t\t\t<th>NIC</th>\n\t\t\t<th>EEPROM/NVMバージョン</th>\n\t\t\t<th>OROMバージョン</th>\n\t\t</tr>\n\t</thead>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2ポート 560FLBアダプター</td>\n\t\t\t<td>800008F0</td>\n\t\t\t<td>1.2836.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2ポート560Mアダプター</td>\n\t\t\t<td>8000083D</td>\n\t\t\t<td>1.2836.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>コンボイメージv1.2836.0は以下を含みます：ブートエージェント：1GbE - v1.5.88、10GbE - v2.4.44、40GbE - v1.1.18 &UEFIドライバー：1GbE - v9.4.06、10GbE - v7.8.13、40GbE - v4.4.12</p>\n"}],"files":[{"bytes":"8243623","datemodified":"2021-03-09T17:58:40","file_list":["./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/CP045078.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/CP045078.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/deps/libs/libnvmupdatelinux.so","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/nic_fw/BootIMG.FLB","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/nic_fw/HPE_560FLB_G33590-000_2.45_800008F0.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/nic_fw/HPE_560M_G43498-00X_2.18_8000083D.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/nic_fw/HPE_XG_Adapter_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/nic_fw/hpesinglenvmconfig.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/nic_fw/hpnvmupdate.cfg","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/nic_fw/nvmupdate.sh","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/nic_fw/ofvpdfix64e","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/nic_fw/rfendfix64e","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045078.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045078.scexe"],"md5sum":"55753286ff1cc2ba87f8059fd4015d6e","name":"firmware-nic-intel-bl-1.2.3-1.1.x86_64.rpm","release":"2021-03-31T00:00:00","revision":"1","sha1sum":"f298bc0185b14c3c82cdf60cd9c09d77c8068de5","size":"7MB","target_guids":["a6b1a447-382a-5a4f-8086-10F8103C18D0","a6b1a447-382a-5a4f-8086-10F8103C17D2"],"type_of_change":"0","version":"1.2.3"}],"id":{"product":"efc60b9bf1a141328e5b2c582be6ef7b","version":"25702105733f4cbc858bd4c6e43ab3ca"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf57995ac","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.6.4-1","description":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"12.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf57995ac","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.6.4-1","description":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf57995ac","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.6.4-1","description":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"15.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf57995ac","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.6.4-1","description":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"7.6"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec05844b56","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.6.4-1","description":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"7.7"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec05844b56","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.6.4-1","description":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"8.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec05844b56","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.6.4-1","description":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgben Driver version 1.7.20-1OEM.600.0.0.2768847 or greater is required and should be already active","OSVersion":{"name":"VMWare","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4a9c3d5c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.7.20-1OEM.600.0.0.2768847","description":"HPE Blade Intel ixgben Driver version 1.7.20-1OEM.600.0.0.2768847 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgben Driver version 1.7.20-1OEM.670.0.0.8169922 or greater is required and should be already active","OSVersion":{"name":"VMWare","value":"6.7"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4a9c3d5c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.7.20-1OEM.670.0.0.8169922","description":"HPE Blade Intel ixgben Driver version 1.7.20-1OEM.670.0.0.8169922 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Blade Intel ixgben Driver version 1.8.9.0-1OEM.700.1.0.15525992 or greater is required and should be already active","OSVersion":{"name":"VMWare","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.8.9.0-1OEM.700.1.0.15525992","description":"HPE Blade Intel ixgben Driver version 1.8.9.0-1OEM.700.1.0.15525992 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><em><strong>Steps to update the adapter firmware using the rpm pacakge:</strong></em></p>\n\n<ul>\n\t<li>Install the firmware rpm package:<br />\n\t<em>&gt; rpm -ivh &lt;rpm_filename&gt;.rpm </em></li>\n\t<li>Check where the files are extracted:<br />\n\t<em>&gt; rpm -qlp &lt;rpm_filename&gt;.rpm</em></li>\n\t<li>Using the output from the previous step determine the location of hpsetup file, change to that directory and run &#39;<em>./hpsetup</em>&#39; to update the firmware.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li>\n\t<li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware, it merely extracts the contents of the rpm package to the local system. Updating the adapter firmware requires following the steps outlined above.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><em><strong>rpmパッケージを使用してアダプターファームウェアをアップデートする手順：</strong></em></p>\n\n<ul>\n\t<li>ファームウェアrpmパッケージをインストールします。<br />\n\t<em>> rpm -ivh <rpm_filename>.rpm </em></li>\n\t<li>ファイルを抽出する場所を確認します。<br />\n\t<em>> rpm -qlp <rpm_filename>.rpm</em></li>\n\t<li>前のステップからの出力を使用してhpsetupファイルの場所を判別し、そのディレクトリに変更して'<em>./hpsetup</em>'を実行してファームウェアをアップデートします。</li>\n</ul>\n\n<p> </p>\n\n<p><strong><em>追加情報：</em></strong></p>\n\n<ul>\n\t<li>ファームウェアのアップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</li>\n\t<li>ファームウェアのrpmパッケージ（rpm -ivh）をインストールしてもアダプターファームウェアはアップデートされず、rpmパッケージの内容がローカルシステムに抽出されるだけです。アダプターファームウェアをアップデートするには、上記の手順に従う必要があります。</li>\n</ul>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Intel Online Firmware Upgrade Utility for Linux"},{"lang":"ja","x_late":"HPE Blade Intelオンラインファームウェアアップグレードユーティリティ for Linux"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-30T17:45:10","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 7, Updates 8 and 9.<br />\nThis product now supports Red Hat Enterprise Linux 8, Updates 2&nbsp;and 3.<br />\nThis product now supports SUSE Linux Enterprise Server 12 SP5.<br />\nThis product now supports SUSE Linux Enterprise Server 15 SP2.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 7, Updates 8 and 9.<br />\nThis product now supports Red Hat Enterprise Linux 8, Updates 2&nbsp;and 3.<br />\nThis product now supports SUSE Linux Enterprise Server 12 SP5.<br />\nThis product now supports SUSE Linux Enterprise Server 15 SP2.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"INTEL_BL","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900374","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware and boot BIOS of Emulex Fibre Channel host bus adapters."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"14243864","datemodified":"2021-08-31T08:26:15","file_list":["./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2021.10.01-1.6","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2021.10.01-1.6/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2021.10.01-1.6/.setup","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2021.10.01-1.6/CP048598.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2021.10.01-1.6/boot","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2021.10.01-1.6/boot/UU1280A3.PRG","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2021.10.01-1.6/elxflashStandalone-linux-12.8.528.12-1.zip","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2021.10.01-1.6/firmware","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2021.10.01-1.6/firmware/A12852812.grp","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2021.10.01-1.6/firmware/B12852812.grp","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2021.10.01-1.6/firmware/UD210X6.ALL","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2021.10.01-1.6/fwmatrix.txt","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2021.10.01-1.6/hpe_fw_matrix.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2021.10.01-1.6/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2021.10.01-1.6/payload.json","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2021.10.01-1.6/readme.txt","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2021.10.01-1.6/reference.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2021.10.01-1.6/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048598.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048598.scexe"],"md5sum":"35e665b69b22a4695be3606049f1caff","name":"firmware-fc-emulex-2021.10.01-1.6.x86_64.rpm","release":"2021-08-31T08:12:59","revision":"0","sha1sum":"afd83d382f8f35852de1208c7714553a1580a439","size":"13MB","target_guids":[],"type_of_change":"1","version":"2021.10.01"}],"id":{"product":"c092e71ed1fc487aae1a961cd9bb8693","version":"771f81a58b5e4272b916ac2ea99d2fc6"},"installation":{"command":"installer","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Firmware installation is a two-step process.&nbsp; Install the firmware installation tool rpm, then execute the installed tool to update the firmware.<br />\n&nbsp;<br />\n&nbsp;1. Install the firmware installation tool:&nbsp; rpm -Uvh &lt;rpm_package_name&gt;.rpm&nbsp; This extracts the firmware installation tool to /usr/lib/x86_64-linux-gnu (64-bit systems) .<br />\n&nbsp;<br />\n&nbsp;2. cd to the appropriate location for your system, and update the firmware by executing ./setup<br />\n&nbsp;<br />\n&nbsp;When the firmware installation completes, you may remove the firmware installation tool from your system using the rpm -e command : rpm -e &lt;rpm_package_name&gt;.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Fibre Channel Host Bus Adapters for Linux (x64)"}],"prerequisites":{"required_diskspace":{"size_kb":"20000"},"supported_devices":[{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T10:35:43","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Adapter</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Speed</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Universal Boot Image</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Firmware</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>UEFI</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Boot Bios</strong></p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE 81E 8Gb Single Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.80a3</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">2.10X6</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.183.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.9.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE 82E 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.80a3</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">2.10X6</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.183.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.9.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE 84E 8Gb Quad Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.80a3</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">2.10X6</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.183.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.9.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1000E 16Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1000E 16Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100E 16Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100E 16Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100E Quad Port 16Gb Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"emulex","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000GWXKK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG08acHPG3.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304757584b4b","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB016000GWXKK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;-&nbsp;MB016000GWXKK Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"5533479","datemodified":"2021-07-26T16:40:28","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG3-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG3-2.1/CP049129.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG3-2.1/TAMG08acHPG3.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG3-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049129.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049129.scexe"],"md5sum":"ed7517c851a6c4a5eda69c291168d1fb","name":"firmware-hdd-e4f147cdd2-HPG3-2.1.x86_64.rpm","release":"2021-07-26T16:27:04","revision":"0","sha1sum":"86b88f4155204df9c53d583c8514143c770bc75b","size":"5MB","target_guids":["4d2340a5-3042-3631-3030-304757584b4b"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"d780ef43938c40d3a6628583fe2200f7","version":"594d2b7521c8423cbc6dbf27c29d0773"},"installation":{"command":"CP040352.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB016000GWXKK Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB016000GWXKK","target_guid":"4d2340a5-3042-3631-3030-304757584b4b","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T16:22:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB016000GWXKK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB1000GVYZE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3142-3030-304756595a45","Version":"HPG4"},{"DeviceName":"MB2000GVYZF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304756595a46","Version":"HPG4"},{"DeviceName":"MB3000GVYZH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304756595a48","Version":"HPG4"},{"DeviceName":"MB4000GVYZK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304756595a4b","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SATA drive models: MB1000GVYZE, MB2000GVYZF, MB3000GVYZH, and MB4000GVYZK"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。MB1000GVYZE、MB2000GVYZF、MB3000GVYZHおよびMB4000GVYZK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB1000GVYZE, MB2000GVYZF, MB3000GVYZH&nbsp;and MB4000GVYZK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5287261","datemodified":"2021-07-23T06:08:20","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7010918e-HPG4-10.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7010918e-HPG4-10.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7010918e-HPG4-10.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7010918e-HPG4-10.1/CP048146.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7010918e-HPG4-10.1/SMBPNTG4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7010918e-HPG4-10.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7010918e-HPG4-10.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7010918e-HPG4-10.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7010918e-HPG4-10.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048146.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048146.scexe"],"md5sum":"03db0e2543ea3245862839b0c22c3ef2","name":"firmware-hdd-0a7010918e-HPG4-10.1.x86_64.rpm","release":"2021-07-23T05:56:08","revision":"0","sha1sum":"1b279240bcc073fc0d8f9829b7d83862eb268221","size":"5MB","target_guids":["002340a5-4d00-3142-3030-304756595a45","002340a5-4d00-3242-3030-304756595a46","002340a5-4d00-3342-3030-304756595a48","002340a5-4d00-3442-3030-304756595a4b"],"type_of_change":"1","version":"HPG4"}],"id":{"product":"a436ff0616cd485d9ad02a8eddc12852","version":"5c9143dd6a644bafa0b425b7ef13562c"},"installation":{"command":"CP040311.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB1000GVYZE, MB2000GVYZF, MB3000GVYZH and MB4000GVYZK Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB1000GVYZE、MB2000GVYZF、MB3000GVYZH、およびMB4000GVYZKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB1000GVYZE","target_guid":"002340a5-4d00-3142-3030-304756595a45","type":"sata"},{"id":"MB2000GVYZF","target_guid":"002340a5-4d00-3242-3030-304756595a46","type":"sata"},{"id":"MB3000GVYZH","target_guid":"002340a5-4d00-3342-3030-304756595a48","type":"sata"},{"id":"MB4000GVYZK","target_guid":"002340a5-4d00-3442-3030-304756595a4b","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-26T18:36:55","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB3000GVYZH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB2000GVYZF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB1000GVYZE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB4000GVYZK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWRTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57525448","Version":"HPD2"},{"DeviceName":"MB012000JWRTF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57525446","Version":"HPD2"},{"DeviceName":"MB010000JWRTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a57525445","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB014000JWRTH, MB012000JWRTF and MB010000JWRTE"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB014000JWRTH、MB012000JWRTFおよびMB010000JWRTE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB014000JWRTH, MB012000JWRTF and MB010000JWRTE&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"4083432","datemodified":"2021-07-23T06:50:57","file_list":["cp048547.xml","cpqsetup.exe","payload.json","setup.dll","SMOBULABPSD2.rel"],"md5sum":"24f1e5973bc4dff78016ca9c98e7d9dd","name":"cp048547.exe","release":"2021-07-23T06:43:05","revision":"0","sha1sum":"ed414e4985e5c9606aa2a853b58d60561ea12062","size":"3MB","target_guids":["4d2340a5-3042-3431-3030-304a57525448","4d2340a5-3042-3231-3030-304a57525446","4d2340a5-3042-3031-3030-304a57525445"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"63976963938d4f79be04f7b652abb966","version":"e0a349de03494ac58e51819e0dbd30d1"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB014000JWRTH, MB012000JWRTF and MB010000JWRTE Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB014000JWRTH、MB012000JWRTFおよびMB010000JWRTE ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB014000JWRTH","target_guid":"4d2340a5-3042-3431-3030-304a57525448","type":"sas"},{"id":"MB012000JWRTF","target_guid":"4d2340a5-3042-3231-3030-304a57525446","type":"sas"},{"id":"MB010000JWRTE","target_guid":"4d2340a5-3042-3031-3030-304a57525445","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T14:59:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB014000JWRTH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB010000JWRTE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB012000JWRTF","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built for Red Hat Enterprise Linux 8 (64-bit) to enable the HPE Smart Array B140i SATA RAID controller."},{"lang":"ja","x_late":"このRPMを使用して、HPE Smart Array B140i SATA RAIDコントローラーを有効にする、Red Hat Enterprise Linux 8（64-bit）用のビルド済みバイナリドライバーモジュールを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[],"files":[{"bytes":"987985","datemodified":"2021-06-08T11:05:23","file_list":["./etc/depmod.d/hpdsa.conf","./lib/modules/4.18.0-305.el8.x86_64","./lib/modules/4.18.0-305.el8.x86_64/extra","./lib/modules/4.18.0-305.el8.x86_64/extra/hpdsa","./lib/modules/4.18.0-305.el8.x86_64/extra/hpdsa/hpdsa.ko","./usr/share/smartupdate/kmod-hpdsa/component.xml"],"md5sum":"6f255d62fbb96e3e2c5dfe4bcbb5edca","name":"kmod-hpdsa-1.2.10-196.rhel8u4.x86_64.rpm","release":"2021-06-08T10:52:09","revision":"0","sha1sum":"0b6d5183a7ea24205523e68684a26ec8dfc771aa","size":"964KB","target_guids":[],"type_of_change":"1","version":"1.2.10-196"},{"bytes":"986596","datemodified":"2021-06-08T11:12:50","file_list":["./etc/depmod.d/hpdsa.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/hpdsa","./lib/modules/4.18.0-240.el8.x86_64/extra/hpdsa/hpdsa.ko","./usr/share/smartupdate/kmod-hpdsa/component.xml"],"md5sum":"dbdcfe52885328e360d89dd9fcfb0768","name":"kmod-hpdsa-1.2.10-196.rhel8u3.x86_64.rpm","release":"2021-06-08T10:52:09","revision":"0","sha1sum":"08f90bf27c355158b732517ed1236c76755fefe4","size":"963KB","target_guids":[],"type_of_change":"1","version":"1.2.10-196"}],"id":{"product":"791b93a05ce5422ca9f4427d20cc71b3","version":"df727c2e4ee54e03b3dab794aa2bc79b"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as the system administrator (root), download the RPM to a directory on<br />\nyour hard drive and change to that directory.</p>\n\n<p dir=\"ltr\"><strong>To install&nbsp;or&nbsp;upgrade&nbsp;the driver type:</strong></p>\n\n<p># rpm -Uvh kmod-hpdsa-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</p>\n\n<p>Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p dir=\"ltr\">NOTE: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:</p>\n\n<p dir=\"ltr\"># rpm -e kmod-hpdsa-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</p>\n\n<p dir=\"ltr\">&nbsp;</p>\n\n<p dir=\"ltr\"><strong><u>Enterprise Support</u></strong><br />\nFor support on Smart Array controllers, visit&nbsp;<a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a></p>\n"},{"lang":"ja","x_late":"<p>システム管理者（root）としてログインし、RPMを<br />\nご使用のハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</p>\n\n<p dir=\"ltr\"><strong>ドライバーをインストールまたはアップグレードするには次のようにタイプします。</strong></p>\n\n<p># rpm -Uvh kmod-hpdsa-<version>.<OSupdate>.x86_64.rpm</p>\n\n<p>Setup is now complete. コンピューターをただちに再起動してください。</p>\n\n<p dir=\"ltr\">注記：インストールの失敗、あるいは警告やエラーメッセージを表示して停止した場合は、コンピューターを再起動しないでください。ドライバーは動作しないため、以下のコマンドをタイプしてアンインストールしてください。</p>\n\n<p dir=\"ltr\"># rpm -e kmod-hpdsa-<version>.<OSupdate>.x86_64.rpm</p>\n\n<p dir=\"ltr\"> </p>\n\n<p dir=\"ltr\"><strong><u>エンタープライズサポート</u></strong><br />\nSmartアレイコントローラーのサポートに関しては、<a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a>を参照してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Dynamic Smart Array B140i SATA RAID Controller Driver for Red Hat Enterprise Linux 8 (64-bit)"},{"lang":"ja","x_late":"Red Hat Enterprise Linux 8（64-bit）用HPE Dynamic SmartアレイB140i SATA RAIDコントローラードライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"8D06","subdev":"009C","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"8D66","subdev":"009D","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"193F","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"A106","subdev":"00C0","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"A107","subdev":"00C0","subven":"1590","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-06T07:33:19","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added Support for Red Hat Enterprise Linux 8.2</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added Support for Red Hat Enterprise Linux 8.4</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U25","value":"HP ProLiant XL280d Accelerator Tray - cancelled"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"kmod-hpdsa","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hpdsa","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hpdsa","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hpdsa","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE ProLiant Smart Array Px4x and Hx4x series controllers.  This RPM provides a customer friendly approach to install a pre-built binary driver.\nOn some kernel erratas the version of the driver present in the kernel may be equal to the version being installed by the rpm.  However, the driver in the kernel may not include all of the fixes and enhancements implemented in the driver contained within the rpm.  Therefore the rpm should be installed in order to obtain the fixes and enhancements that are not present in the kernel driver."},{"lang":"ja","x_late":"このRPMは、HPE ProLiant SmartアレイPx4xおよびHx4xシリーズコントローラーを有効にするためのプレビルドバイナリドライバーモジュールを提供します。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。errataカーネルによっては、カーネル内に存在するドライバーのバージョンとrpmによってインストールされたバージョンが等しい場合があります。だたし、カーネル内のドライバーは、rpmに含まれるドライバーに対して行われた、すべての修正と拡張が含まれていないことがあります。そのため、rpmはカーネルドライバーに存在しない、修正と拡張を入手するため、インストールする必要があります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"77706","datemodified":"2021-04-28T10:18:40","file_list":["./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/hpsa.ko","./usr/share/smartupdate/hpsa-kmp-default/component.xml"],"md5sum":"1942d42f200649a99ef63bd5be62f576","name":"hpsa-kmp-default-3.4.20-188.sles12sp4.x86_64.rpm","release":"2021-04-28T10:01:05","revision":"0","sha1sum":"491822441c5352ca96e2d387368db80d78441887","size":"75KB","target_guids":[],"type_of_change":"1","version":"3.4.20-188"},{"bytes":"77188","datemodified":"2021-04-28T10:13:02","file_list":["./lib/modules/4.12.14-115-default","./lib/modules/4.12.14-115-default/updates","./lib/modules/4.12.14-115-default/updates/hpsa.ko","./usr/share/smartupdate/hpsa-kmp-default/component.xml"],"md5sum":"b829515301080d2fbe9e7b1d1cca305e","name":"hpsa-kmp-default-3.4.20-188.sles12sp5.x86_64.rpm","release":"2021-04-28T10:01:05","revision":"0","sha1sum":"86891b20b8a32efb633c8559fccfb6791d90ce0e","size":"75KB","target_guids":[],"type_of_change":"1","version":"3.4.20-188"}],"id":{"product":"fb6a68c03bce4024bbd1868e36b3725e","version":"7851e8b787a940fdb6cd560eb34c87c9"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as the system administrator (root), download the RPM to a directory on<br />\nyour hard drive and change to that directory.</p>\n\n<p><strong>To install or upgrade&nbsp;the driver type:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li># rpm -Uvh hpsa-kmp-default-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm&nbsp;&nbsp;</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p style=\"margin-right:0px\">Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p><strong>NOTE</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:</p>\n\n<ul>\n\t<li># rpm -e hpsa-kmp-default-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</li>\n</ul>\n\n<p><strong><u>Enterprise Support</u></strong><br />\nFor support on Smart Array controllers, visit <a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a></p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>システム管理者（root）としてログインし、RPMを<br />\nご使用のハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</p>\n\n<p><strong>ドライバーをインストールまたはアップグレードするには次のようにタイプします。</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li># rpm -Uvh hpsa-kmp-default-<version>.<OSupdate>.x86_64.rpm  </li>\n</ul>\n\n<p> </p>\n\n<p style=\"margin-right:0px\">Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p><strong>注</strong>：インストールの失敗、あるいは警告やエラーメッセージを表示して停止した場合は、コンピューターを再起動しないでください。ドライバーは動作しないため、以下のコマンドをタイプしてアンインストールしてください。</p>\n\n<ul>\n\t<li># rpm -e hpsa-kmp-default-<version>.<OSupdate>.x86_64.rpm</li>\n</ul>\n\n<p><strong><u>Enterprise Support</u></strong><br />\nSmartアレイコントローラーのサポートに関しては、<a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a>を参照してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE ProLiant Smart Array Controller (64-bit) Driver for SUSE LINUX Enterprise Server 12 (64-bit)"},{"lang":"ja","x_late":"SUSE LINUX Enterprise Server 12（64-bit）用HPE ProLiant Smartアレイコントローラー（64-bit）ドライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"323c","subdev":"1928","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21BD","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ca","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1922","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1923","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c2","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c0","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c3","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1926","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21be","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3353","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1924","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1921","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cb","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c1","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c5","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21CD","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cc","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3355","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3350","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3351","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3354","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3352","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323B","subdev":"3356","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3239","subdev":"21c7","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21bf","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c8","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c6","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ce","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-27T05:36:39","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Add support for SuSE Linux Enterprise Server 12 SP5</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Add support for SuSE Linux Enterprise Server 12 SP5</li>\n\t<li>Added PKCS signing process to fix the secure boot hang issue on Linux SLES12 SP5</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P74","value":"HP ProLiant SL140s Gen8 Server (private)"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 v2 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"P83","value":"HP ProLiant SL210t Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I14","value":"HP ProLiant BL480c Server"}],"sw_keys":[{"name":"hpsa-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hpsa-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hpsa-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hpsa-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5700-764285-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F4","Version":"2.42.5700"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5056-764283-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F2","Version":"2.42.5056"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5056-764284-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F3","Version":"2.42.5056"},{"DeviceName":"HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5000-764286-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F5","Version":"2.42.5000"},{"DeviceName":"HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5000-764282-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F1","Version":"2.42.5000"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Mellanox VPI (Ethernet and Infiniband mode of operation) adapter firmware on VMware ESXi 6.5"},{"lang":"ja","x_late":"このパッケージは、VMware ESXi 6.5上でHPE Mellanox VPI (EthernetおよびInfinibandモードで動作) アダプターファームウェアをアップグレードするためのユーティリティおよびバイナリを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>InfiniBand Card Type</strong></td>\n\t\t\t<td><strong>Firmware&nbsp;Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+M Adapter (764282-B21)</td>\n\t\t\t<td>2.42.5000</td>\n\t\t\t<td>HP_1350110023</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+M Adapter (764283-B21)</td>\n\t\t\t<td>2.42.5056</td>\n\t\t\t<td>HP_1360110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+QSFP Adapter (764284-B21)</td>\n\t\t\t<td>2.42.5056</td>\n\t\t\t<td>HP_1370110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+FLR-QSFP Adapter (764285-B21)</td>\n\t\t\t<td>2.42.5700</td>\n\t\t\t<td>HP_1380110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+FLR-QSFP Adapter (764286-B21)</td>\n\t\t\t<td>2.42.5000</td>\n\t\t\t<td>HP_1390110023</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"19226869","datemodified":"2021-02-03T03:26:06","file_list":["/CP045902.vmexe","/CP045902.vmfile","/CP045902_VMw.zip","/CP045902.xml","/payload.json","/README.txt","/CP045902_VMw.zip/index.xml","/CP045902_VMw.zip/vendor-index.xml","/CP045902_VMw.zip/metadata.zip","/CP045902_VMw.zip/vib20/CP045902/HPE_bootbank_CP045902_1.0.1-6.5.0.4240417.vib","/CP045902_VMw.zip/metadata.zip/vendor-index.xml","/CP045902_VMw.zip/metadata.zip/vmware.xml","/CP045902_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045902_1.0.1-6.5.0.4240417.xml","/CP045902_VMw.zip/metadata.zip/vibs/CP045902-3689128572757422720.xml"],"md5sum":"7ef2fa5fcdeda7baa7a781a13bc510cb","name":"CP045902.zip","release":"2021-02-03T03:32:05","revision":"0","sha1sum":"a312f7e5a269d8b8936daec7b2d85b25d06893b3","size":"18MB","target_guids":["a6b1a447-382a-5a4f-15B3-1007103C22F4","a6b1a447-382a-5a4f-15B3-1007103C22F2","a6b1a447-382a-5a4f-15B3-1007103C22F3","a6b1a447-382a-5a4f-15B3-1007103C22F5","a6b1a447-382a-5a4f-15B3-1007103C22F1"],"type_of_change":"1","version":"1.0.7","vib_list":[{"name":"CP045902","version":"1.0.1-6.5.0.4240417"}]}],"id":{"product":"7a662f7d75e94013936ff11b1e7b1553","version":"5249928f049242e2998a48ccc80bb585"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Offline: &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p>\n\n<p>Remote Online, if the component is supported by SUM but is not yet part of an SPP:<br />\n&nbsp; &nbsp; Download the appropriate SPP<br />\n&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />\n&nbsp; &nbsp; Run SUM<br />\n&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />\n&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />\n&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />\n&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />\n&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />\n&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at: <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p>\n\n<p>Note: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p>\n\n<p>To use HPE Insight Control for vCenter: &nbsp;<br />\n&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />\n&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p>\n\n<p>To update firmware from VMware ESXi operating system on target server: &nbsp;<br />\n&nbsp; &nbsp; Enable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Login as root. (You must be root in order to apply the update) &nbsp;<br />\n&nbsp; &nbsp; Place the Smart Component in a temporary directory<br />\n&nbsp; &nbsp; Check if the nmst module is loaded already: vmkload_mod -l | grep nmst<br />\n&nbsp; &nbsp; If module is not loaded, use the command to load the module: vmkload_mod nmst<br />\n&nbsp; &nbsp; From the same directory, execute the Smart Component. For example: unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe<br />\n&nbsp; &nbsp; Follow the directions given by the Smart Component.<br />\n&nbsp; &nbsp; Logout.<br />\n&nbsp; &nbsp; Disable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Reboot your system, if required, for the firmware update to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (ESXi 6.5) for HPE Mellanox VPI (Ethernet and Infiniband mode) devices on VMware ESXi 6.5"},{"lang":"ja","x_late":"オンラインファームウェアアップグレードユーティリティ (ESXi 6.5) for HPE Mellanox VPI (EthernetおよびInfinibandモード) デバイス - VMware ESXi 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-10-16T19:30:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5000:</strong><br />\n&nbsp;&nbsp; &nbsp;764282-B21<br />\n&nbsp;&nbsp; &nbsp;764286-B21&nbsp;&nbsp;</p>\n\n<p><strong>Firmware for the following devices are updated to 2.42.5056:</strong><br />\n&nbsp;&nbsp; &nbsp;764283-B21<br />\n&nbsp;&nbsp;&nbsp;&nbsp;764284-B21</p>\n\n<p><strong>Firmware for the following device&nbsp;is&nbsp;updated to 2.42.5700:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;764285-B21</p>\n\n<p><strong>New features in firmware version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>Added support for the following features.\n\t<ul>\n\t\t<li>new TLV: CX3_GLOBAL_CONF to enable/disable timestamp on incoming packets through mlxconfig configuration.</li>\n\t\t<li>User MAC configuration.</li>\n\t\t<li>Automatically collecting mstdump before driver reset.</li>\n\t\t<li>A&nbsp;mechanism to detect DEAD_IRISC (plastic) from TPT (iron) and raise an assert.</li>\n\t\t<li>A new field is added to &quot;set port&quot; command which notifies the firmware what is the user_mtu size.</li>\n\t</ul>\n\t</li>\n\t<li>Improved the debug ability for command timeout cases.</li>\n</ul>\n\n<p><strong>New features and changes&nbsp;in firmware version 2.42.5700.</strong></p>\n\n<ul>\n\t<li>Modified the mlx_cmd_get_mlx_link_status command return value to return &quot;Link Type = Ethernet&quot; in Ethernet adapter cards.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Fixes in version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>PortRcvPkts counter was prevented from being cleared after&nbsp;resetting it.</li>\n\t<li>The system&nbsp;Timed Out on the configuration cycle of&nbsp;the Virtual Functions (VFs) when more than 10 Virtual Functions&nbsp;performed FLR and the completion Time Out&nbsp;value was configured to a range of less than&nbsp;16 msec.</li>\n\t<li>The server hangs and results in NMI when running&nbsp;&ldquo;mlxfwtop &ndash;d mt4103_pci_cr0&rdquo; while&nbsp;restarting the driver in parallel (from a different&nbsp;thread). In this case, the downstream&nbsp;bridge over the device reported completion&nbsp;timeout error.</li>\n\t<li>In flow_steering,&nbsp;BMC could not receive a ping over&nbsp;IPV6 after running bmc_reboot.</li>\n\t<li>While closing the&nbsp;HCA, the RX packet caused bad access to&nbsp;resources that did not exist, and consequently caused the QPCGW or the irisc to get stuck.</li>\n\t<li>The master SMLID&nbsp;and the LID was either 0 or&nbsp;0xFFFF when the port was neither active nor&nbsp;armed.</li>\n\t<li>ibdump could not capture&nbsp;all MADs packets.</li>\n\t<li>link did not&nbsp;go up after reboot.</li>\n\t<li>Fixed a rare issue that cause the PCIe&nbsp;configuration cycle that arrived during the&nbsp;time of sw_reset to generate 2 completions.</li>\n\t<li>Network Controller Sideband Interface (NC-SI) did not&nbsp;work when adding the disable_static_steering_ini field in the ini file, due to&nbsp;memory allocation issue for this field in the&nbsp;scratchpad.</li>\n</ul>\n\n<p><strong>Fixes in version 2.42.5056:</strong></p>\n\n<ul>\n\t<li>Fixed an issue that resulted in reading from invalid I/O address on handover from UEFI boot to OS boot, when a port was configured as InfiniBand on a VPI adapter device.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5000:</strong><br />\n&nbsp;&nbsp; &nbsp;764282-B21<br />\n&nbsp;&nbsp; &nbsp;764286-B21&nbsp;&nbsp;</p>\n\n<p><strong>Firmware for the following devices are updated to 2.42.5056:</strong><br />\n&nbsp;&nbsp; &nbsp;764283-B21<br />\n&nbsp;&nbsp;&nbsp;&nbsp;764284-B21</p>\n\n<p><strong>Firmware for the following device&nbsp;is&nbsp;updated to 2.42.5700:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;764285-B21</p>\n\n<p><strong>New features in firmware version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>Added support for the following features.\n\t<ul>\n\t\t<li>new TLV: CX3_GLOBAL_CONF to enable/disable timestamp on incoming packets through mlxconfig configuration.</li>\n\t\t<li>User MAC configuration.</li>\n\t\t<li>Automatically collecting mstdump before driver reset.</li>\n\t\t<li>A&nbsp;mechanism to detect DEAD_IRISC (plastic) from TPT (iron) and raise an assert.</li>\n\t\t<li>A new field is added to &quot;set port&quot; command which notifies the firmware what is the user_mtu size.</li>\n\t</ul>\n\t</li>\n\t<li>Improved the debug ability for command timeout cases.</li>\n</ul>\n\n<p><strong>New features and changes&nbsp;in firmware version 2.42.5700.</strong></p>\n\n<ul>\n\t<li>Modified the mlx_cmd_get_mlx_link_status command return value to return &quot;Link Type = Ethernet&quot; in Ethernet adapter cards.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Fixes in version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>PortRcvPkts counter was prevented from being cleared after&nbsp;resetting it.</li>\n\t<li>The system&nbsp;Timed Out on the configuration cycle of&nbsp;the Virtual Functions (VFs) when more than 10 Virtual Functions&nbsp;performed FLR and the completion Time Out&nbsp;value was configured to a range of less than&nbsp;16 msec.</li>\n\t<li>The server hangs and results in NMI when running&nbsp;&ldquo;mlxfwtop &ndash;d mt4103_pci_cr0&rdquo; while&nbsp;restarting the driver in parallel (from a different&nbsp;thread). In this case, the downstream&nbsp;bridge over the device reported completion&nbsp;timeout error.</li>\n\t<li>In flow_steering,&nbsp;BMC could not receive a ping over&nbsp;IPV6 after running bmc_reboot.</li>\n\t<li>While closing the&nbsp;HCA, the RX packet caused bad access to&nbsp;resources that did not exist, and consequently caused the QPCGW or the irisc to get stuck.</li>\n\t<li>The master SMLID&nbsp;and the LID was either 0 or&nbsp;0xFFFF when the port was neither active nor&nbsp;armed.</li>\n\t<li>ibdump could not capture&nbsp;all MADs packets.</li>\n\t<li>link did not&nbsp;go up after reboot.</li>\n\t<li>Fixed a rare issue that cause the PCIe&nbsp;configuration cycle that arrived during the&nbsp;time of sw_reset to generate 2 completions.</li>\n\t<li>Network Controller Sideband Interface (NC-SI) did not&nbsp;work when adding the disable_static_steering_ini field in the ini file, due to&nbsp;memory allocation issue for this field in the&nbsp;scratchpad.</li>\n</ul>\n\n<p><strong>Fixes in version 2.42.5056:</strong></p>\n\n<ul>\n\t<li>Fixed an issue that resulted in reading from invalid I/O address on handover from UEFI boot to OS boot, when a port was configured as InfiniBand on a VPI adapter device.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_VPI","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Intel i40en Adapters running under VMware vSphere 7.0"},{"lang":"ja","x_late":"この製品は、VMware vSphere 7.0上で動作するHPE Intel i40enアダプターのためのドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;1.10.9.0.</p>\n"},{"lang":"ja","x_late":"<p>この製品には、ドライバーバージョン1.10.9.0が含まれています。</p>\n"}],"files":[{"bytes":"220236","datemodified":"2021-09-05T12:33:58","file_list":["/cp049458.xml","/Intel-i40en_1.10.9.0-1OEM.700.1.0.15525992_16030650.zip","/Intel-i40en_1.10.9.0-1OEM.700.1.0.15525992_16030650.zip/index.xml","/Intel-i40en_1.10.9.0-1OEM.700.1.0.15525992_16030650.zip/vendor-index.xml","/Intel-i40en_1.10.9.0-1OEM.700.1.0.15525992_16030650.zip/metadata.zip","/Intel-i40en_1.10.9.0-1OEM.700.1.0.15525992_16030650.zip/vib20/i40en/INT_bootbank_i40en_1.10.9.0-1OEM.700.1.0.15525992.vib","/Intel-i40en_1.10.9.0-1OEM.700.1.0.15525992_16030650.zip/metadata.zip/vendor-index.xml","/Intel-i40en_1.10.9.0-1OEM.700.1.0.15525992_16030650.zip/metadata.zip/vmware.xml","/Intel-i40en_1.10.9.0-1OEM.700.1.0.15525992_16030650.zip/metadata.zip/vibs/i40en--20899530716261387.xml","/Intel-i40en_1.10.9.0-1OEM.700.1.0.15525992_16030650.zip/metadata.zip/bulletins/Intel-i40en_1.10.9.0-1OEM.700.1.0.15525992.xml"],"md5sum":"fcbf7b91c75aa76fdbc2e17026d383fe","name":"cp049458.zip","release":"2021-09-05T12:30:00","revision":"0","sha1sum":"c5ffe547307fdf899757bb2e312330fbf7bdc285","size":"215KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec17ceb7c3","20a6e8e4-bf33-4c71-a6bf-d9ec09108524"],"type_of_change":"0","version":"2020.05.29","vib_list":[{"name":"i40en","version":"1.10.9.0-1OEM.700.1.0.15525992"}]}],"id":{"product":"d892124a7e30440eb7f95535da6dada7","version":"da0d0e53714f403a8aed1ee826874e5b"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバーにUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel i40en Driver for VMware vSphere 7.0"},{"lang":"ja","x_late":"HPE Intel i40enドライバーfor VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"},{"dev":"1572","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1572808600a1","type":"pci","ven":"8086"},{"dev":"1572","subdev":"0008","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-157280860008","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-10-02T12:56:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product supports the following new server:</p>\n\n<ul>\n\t<li>HPE ProLiant DL20 Gen10 Plus Server</li>\n\t<li>HPE ProLiant ML30 Gen10 Plus Server&nbsp;<br />\n\t&nbsp;</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"}],"sw_keys":[{"name":"i40en:1.10.9.0-1OEM.700.1.0.15525992","sw_key_expectedpath":"driver:vmware:zip"},{"name":"Intel-i40en:1.10.9.0-1OEM.700.1.0.15525992","sw_key_expectedpath":"driver.component:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXe0HPD7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5748504b","Version":"HPD7"},{"DeviceName":"EH000600JWHPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXe0HPD7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57485048","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EH000900JWHPK and EH000600JWHPH"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EH000900JWHPK および EH000600JWHPH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EH000900JWHPK and EH000600JWHPH Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"16172826","datemodified":"2021-08-27T18:44:30","file_list":["/CP049135_BUILD_1.data","/CP049135.vmexe","/CP049135.vmexe64","/CP049135.vmfile","/CP049135_VMw.zip","/CP049135.xml","/payload.json","/CP049135_VMw.zip/index.xml","/CP049135_VMw.zip/vendor-index.xml","/CP049135_VMw.zip/metadata.zip","/CP049135_VMw.zip/vib20/CP049135/HPE_bootbank_CP049135_HPD7.1-7.0.0.15843807.vib","/CP049135_VMw.zip/metadata.zip/vendor-index.xml","/CP049135_VMw.zip/metadata.zip/vmware.xml","/CP049135_VMw.zip/metadata.zip/vibs/CP049135-1399980518082995242.xml","/CP049135_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049135_HPD7.1-7.0.0.15843807.xml"],"md5sum":"469ca42384224989a671e0fe287ca11a","name":"CP049135.zip","release":"2021-08-27T18:39:17","revision":"0","sha1sum":"2272a93645c426ae1ba8ecb14541609fb29c3aaa","size":"15MB","target_guids":["452340a5-3048-3030-3930-304a5748504b","452340a5-3048-3030-3630-304a57485048"],"type_of_change":"1","version":"HPD7","vib_list":[{"name":"CP049135","version":"HPD7.1-7.0.0.15843807"}]}],"id":{"product":"f7d7f54393d44f66845199e26d4e5900","version":"1d52f2fc65614fe9915bcfedff39a917"},"installation":{"command":"CP042550.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - EH000900JWHPK and EH000600JWHPH   Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - EH000900JWHPKおよびEH000600JWHPHドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EH000900JWHPK","target_guid":"452340a5-3048-3030-3930-304a5748504b","type":"sas"},{"id":"EH000600JWHPH","target_guid":"452340a5-3048-3030-3630-304a57485048","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T17:24:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This firmware fixes a condition that could cause the heads to land on the media in an emergency power off situation, and another condition that can lead to high-fly write, and eliminates a command timeout issue. Some internal logging operations were refined at the same time.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH000600JWHPH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000900JWHPK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VR000150GWEPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDMHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3135-304757455050","Version":"HPG1"},{"DeviceName":"VR000480GWEPR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDMHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3438-304757455052","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VR000150GWEPP and VR000480GWEPR"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：VR000150GWEPP および VR000480GWEPR"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - VR000150GWEPP and VR000480GWEPR Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"2834256","datemodified":"2021-07-22T10:08:58","file_list":["4IDMHPG1.rel","cp048647.xml","cpqsetup.exe","payload.json","setup.dll"],"md5sum":"1050d238e4694b11404046732105e44f","name":"cp048647.exe","release":"2021-07-22T10:01:04","revision":"0","sha1sum":"d3c24cea2fad57c066c7779132a5722df51ccdf4","size":"2MB","target_guids":["562340a5-3052-3030-3135-304757455050","562340a5-3052-3030-3438-304757455052"],"type_of_change":"2","version":"HPG1"}],"id":{"product":"7a5bb5126715458dbee6bc8ea5d0f887","version":"f475a3589fea402694029e839c9be596"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VR000150GWEPP and VR000480GWEPR Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - VR000150GWEPPおよびVR000480GWEPRドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VR000480GWEPR","target_guid":"562340a5-3052-3030-3438-304757455052","type":"sata"},{"id":"VR000150GWEPP","target_guid":"562340a5-3052-3030-3135-304757455050","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T18:19:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":"<ul>\n\t<li>Fixes a timing issue which can cause the drive to become non-functional.</li>\n\t<li>Fixes VPD Log D0h reported drive Sanitize times.</li>\n\t<li>Adds support for Security Log Page BBh.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Fixes a timing issue which can cause the drive to become non-functional.</li>\n\t<li>Fixes VPD Log D0h reported drive Sanitize times.</li>\n\t<li>Adds support for Security Log Page BBh.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VR000480GWEPR","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VR000150GWEPP","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6933164","datemodified":"2021-05-17T23:40:36","file_list":["/CP047864.vmexe","/CP047864.vmfile","/CP047864.xml","/README.txt"],"md5sum":"63487a6efe436f6a62fdf56b0613069f","name":"CP047864.zip","release":"2021-05-18T04:37:14","revision":"0","sha1sum":"2cce60bbe30aed6243e9f156f11ba2bc72d47256","size":"6MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021","vib_list":[]}],"id":{"product":"3592f88084a649b687bec6ded2891596","version":"c5a859a5a47544ceb189263849543953"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component requires that the CRU driver be loaded before the component can run.<br />\nThe minimum CRU version for 5.1 is 5.0.3.9.<br />\nThe minimum CRU version for 5.5 is 5.5.4.1.<br />\nThe minimum CRU version for 6.0 is 6.0.8.<br />\nThe minimum CRU version for 6.5 is 6.5.8.<br />\nThe minimum CRU version for 6.7 is 6.7.10.<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>SPP Offline mode boots a special Linux OS environment, thus the Linux Components are used, not the VMware Components</li>\n</ul>\n\n<p><br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Download the appropriate SPP</li>\n\t<li>Add the component to the SPP</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run SUM</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps to complete the firmware update</li>\n\t<li>Refer to the SPP documentation for detailed instructions at:&nbsp; <a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Component ( CPxxxxxx.zip) in a temporary directory</li>\n\t<li>From the same directory, unzip the Component:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>To perform the standalone installation, execute the command:<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>Follow the directions given by the Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system for the firmware update to take effect</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、実行する前にCRUドライバーがロードされている必要があります。<br />\n5.1の最小CRUバージョンは5.0.3.9です。<br />\n5.5の最小CRUバージョンは5.5.4.1です。<br />\n6.0の最小CRUバージョンは6.0.8です。<br />\n6.5の最小CRUバージョンは6.5.8です。<br />\n6.7の最小CRUバージョンは6.7.10です。<br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMwareコンポーネントではなく、Linuxコンポーネントが用いられます</li>\n</ul>\n\n<p><br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします</li>\n\t<li>SPPにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします</li>\n\t<li>SUMを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います</li>\n\t<li>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>コンポーネント (CPxxxxxx.zip)を一時ディレクトリに置きます</li>\n\t<li>同じディレクトリからコンポーネントをunzipします:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>スタンドアロンのインストールを行うために、次のコマンドを実行します：<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>コンポーネントの指示に従います</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n\t<li>システムを再起動し、ファームウェアのアップデートを有効にします</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware - HPE ProLiant ML150 Gen9 (P95) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for VMware - HPE ProLiant ML150 Gen9（P95）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"5","minor":"1","name":"VMware vSphere 5.1","platform":"vmware_esx_server","sr":"OEM"},{"major":"5","minor":"5","name":"VMware vSphere 5.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-05T06:44:01","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"}],"sw_keys":[{"name":"P95","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains iSCSI drivers for the HPE Blade Emulex 10/20GbE Server Adapters running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 8で動作するHPE Blade Emulex 10/20GbE サーバーアダプター用のiSCSIドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1230284","datemodified":"2021-07-21T18:01:13","file_list":["./etc/depmod.d/be2iscsi.conf","./lib/modules/4.18.0-193.el8.x86_64","./lib/modules/4.18.0-193.el8.x86_64/extra","./lib/modules/4.18.0-193.el8.x86_64/extra/be2iscsi","./lib/modules/4.18.0-193.el8.x86_64/extra/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/kmod-be2iscsi_bl/component.xml"],"md5sum":"14f7a10ca482827811a22d58507ca30b","name":"kmod-be2iscsi_bl-12.0.1342.0-1.rhel8u2.x86_64.rpm","release":"2021-07-21T17:48:16","revision":"0","sha1sum":"51762eb23aa12f71a7ff87ef097ded3f75685fa3","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb2fe523e"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"1265967","datemodified":"2021-07-21T18:00:01","file_list":["./etc/depmod.d/be2iscsi.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/be2iscsi","./lib/modules/4.18.0-240.el8.x86_64/extra/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/kmod-be2iscsi_bl/component.xml"],"md5sum":"6498f0c109c54f627a64c960b195844b","name":"kmod-be2iscsi_bl-12.0.1342.0-1.rhel8u3.x86_64.rpm","release":"2021-07-21T17:48:16","revision":"0","sha1sum":"56420cc902899660391120b34178c34318307995","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb2fe523e"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"29dd95234723495d9d82f8b70f154b42","version":"8e41003a62b545a1b578fa505fc54f60"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>\n\n<p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>\n\n<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>\n\n<p> </p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE iSCSI Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE Blade Emulex 10/20GbE iSCSIドライバー for Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0722","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-09-03T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 8, Updates 2&nbsp;and 3.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports the&nbsp;HPE ProLiant BL660c Gen9 Server.&nbsp;</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"kmod-be2iscsi_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2iscsi_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2iscsi_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2iscsi_bl","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"本產品包含 Red Hat Enterprise Linux 7 x86_64 下執行的 HPE Intel ixgbe 乙太網路 NIC 之 SRIOV 虛擬功能驅動程式。"},{"lang":"en","x_late":"This product contains the SRIOV virtual function drivers for the HPE Intel ixgbe Ethernet NICs running under Red Hat Enterprise Linux 7 x86_64."},{"lang":"ko","x_late":"이 제품에는 Red Hat Enterprise Linux 7 x86_64에서 실행되는 HPE Intel ixgbe 이더넷 NIC용 SRIOV 가상 기능 드라이버가 포함되어 있습니다."},{"lang":"cn","x_late":"本产品包含适用于在 Red Hat Enterprise Linux 7 x86_64 下方运行的 HPE Intel ixgbe 以太网网卡的 SRIOV 虚拟功能驱动程序。"},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7 x86_64で動作するHPE Intel ixgbe Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"62160","datemodified":"2021-01-09T00:27:14","file_list":["./etc/depmod.d/hp-ixgbevf.conf","./etc/dracut.conf.d/hp-ixgbevf-oob.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/hp-ixgbevf","./lib/modules/3.10.0-1127.el7.x86_64/extra/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/kmod-hp-ixgbevf/component.xml"],"md5sum":"b34e4fcde12cb44329ac852d7d69c258","name":"kmod-hp-ixgbevf-4.9.3-1.rhel7u8.x86_64.rpm","release":"2021-01-09T00:05:05","revision":"0","sha1sum":"debba862d8bb45b49a42abd0d6bbaca6ed61059d","size":"60KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eca2355bb8"],"type_of_change":"0","version":"4.9.3-1"},{"bytes":"62157","datemodified":"2021-01-09T00:19:54","file_list":["./etc/depmod.d/hp-ixgbevf.conf","./etc/dracut.conf.d/hp-ixgbevf-oob.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/hp-ixgbevf","./lib/modules/3.10.0-1160.el7.x86_64/extra/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/kmod-hp-ixgbevf/component.xml"],"md5sum":"de4fe2bccd2ec5b02a0aafff99d42ff0","name":"kmod-hp-ixgbevf-4.9.3-1.rhel7u9.x86_64.rpm","release":"2021-01-09T00:05:05","revision":"0","sha1sum":"a6a33a48e1d01dea6c36e9149b2981b03795bba4","size":"60KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eca2355bb8"],"type_of_change":"0","version":"4.9.3-1"}],"id":{"product":"288e2f6737ed4857873f59d466b41139","version":"78cd9574ef4842cc8abee6eb4ef86f92"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"},{"lang":"ja","x_late":"<p>インストールのノートについてREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 Red Hat Enterprise Linux 7 x86_64 的 HPE Intel ixgbevf 驅動程式"},{"lang":"en","x_late":"HPE Intel ixgbevf Drivers for Red Hat Enterprise Linux 7 x86_64"},{"lang":"ko","x_late":"Red Hat Enterprise Linux 7 x86_64용 HPE Intel ixgbevf 드라이버"},{"lang":"cn","x_late":"适用于 Red Hat Enterprise Linux 7 x86_64 的 HPE Intel ixgbevf 驱动程序"},{"lang":"ja","x_late":"HPE Intel ixgbevfドライバー for Red Hat Enterprise Linux 7 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c192d","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c211a","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"},{"dev":"152E","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d3","type":"pci","ven":"8086"},{"dev":"1530","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"1515","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c192d","type":"pci","ven":"8086"},{"dev":"1515","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c211a","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>This product now supports Red Hat Enterprise Linux 7 Update 8</li>\n\t<li>This product update Linux kernel documentation and Configure IRQ affinity tools</li>\n</ul>\n","latest_fixes_x_late":"<p>This product corrects an issue which errata kernel loads inbox driver instead of this component after booting into OS</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>This product now supports Red Hat Enterprise Linux 7 update 9</li>\n\t<li>This product enhances reliability via adding support for new mailbox communication between PF(Physical Function) and VF(Virtual Function) and remove its potential flaws that may lead to the undefined or faulty behavior</li>\n\t<li>This product enhances compatibility where new mailbox api implementation is alo compatible with old drivers</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-hp-ixgbevf","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbevf","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbevf","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbevf","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWKGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAnAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-3047574b4756","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB004000GWKGV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB004000GWKGV Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"4269304","datemodified":"2021-07-23T19:06:04","file_list":["cp048561.xml","cpqsetup.exe","HVLAnAaseFG1.rel","payload.json","setup.dll"],"md5sum":"d0f63565215083b13c1399668dfd6241","name":"cp048561.exe","release":"2021-07-23T18:58:13","revision":"0","sha1sum":"5510641f3e74fdc98f0a4377c0ee1b83f303587e","size":"4MB","target_guids":["4d2340a5-3042-3430-3030-3047574b4756"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"0d61334622ba44aeb0c163514d9f57b9","version":"3be45915be674a4699b3b60eb6c9a576"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB004000GWKGV Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB004000GWKGVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB004000GWKGV","target_guid":"4d2340a5-3042-3430-3030-3047574b4756","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T06:24:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB004000GWKGV","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWCFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757434645","Version":"HPG3"},{"DeviceName":"VK000960GWCFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757434646","Version":"HPG3"},{"DeviceName":"VK000240GWCFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757434644","Version":"HPG3"},{"DeviceName":"VK001920GWCFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757434648","Version":"HPG3"},{"DeviceName":"VK003840GWCFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-30475743464b","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK000240GWCFD, VK000480GWCFE, VK000960GWCFF, VK001920GWCFH and VK003840GWCFK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;VK000240GWCFD, VK000480GWCFE, VK000960GWCFF, VK001920GWCFH and VK003840GWCFK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>AAdded support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"2809080","datemodified":"2021-07-25T18:39:02","file_list":["cp048637.xml","cpqsetup.exe","GP863aG3.rel","payload.json","setup.dll"],"md5sum":"fc15203a89364227630c97ee97810d0d","name":"cp048637.exe","release":"2021-07-25T18:31:05","revision":"0","sha1sum":"b2f639251fc7434a650e32862d3af37699e74c4d","size":"2MB","target_guids":["562340a5-304b-3030-3438-304757434645","562340a5-304b-3030-3936-304757434646","562340a5-304b-3030-3234-304757434644","562340a5-304b-3130-3932-304757434648","562340a5-304b-3330-3834-30475743464b"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"539ed4e104fc49caac711d8c4da1d36a","version":"58160388743c44bb9c5c0cb6c706468f"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK000240GWCFD, VK000480GWCFE, VK000960GWCFF, VK001920GWCFH and VK003840GWCFK  Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - VK000240GWCFD、VK000480GWCFE、VK000960GWCFF、VK001920GWCFHおよびVK003840GWCFKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VK003840GWCFK","target_guid":"562340a5-304b-3330-3834-30475743464b","type":"sata"},{"id":"VK001920GWCFH","target_guid":"562340a5-304b-3130-3932-304757434648","type":"sata"},{"id":"VK000960GWCFF","target_guid":"562340a5-304b-3030-3936-304757434646","type":"sata"},{"id":"VK000480GWCFE","target_guid":"562340a5-304b-3030-3438-304757434645","type":"sata"},{"id":"VK000240GWCFD","target_guid":"562340a5-304b-3030-3234-304757434644","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T16:40:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK001920GWCFH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWCFF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWCFD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWCFE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GWCFK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"Supplemental Update / Online ROM Flash Smart Component which upgrades the enclosure firmware on the HPE Apollo 45xx Gen9 Backplane Expanders"},{"lang":"cn","x_late":"可更新 HP Apollo 45xx Gen9 背板扩展卡机箱固件的补充更新/在线 ROM 刷新组件"},{"lang":"tw","x_late":"補充更新/線上 ROM 更新智慧型元件，可升級 HPE Apollo 45xx Gen9 背板擴充卡的機櫃韌體"},{"lang":"ko","x_late":"HPE Apollo 45xx Gen9 백플레인 익스팬더에서 인클로저 펌웨어를 업그레이드하는 추가 업데이트/온라인 ROM 플래시 스마트 구성요소"},{"lang":"ja","x_late":"HPE Apollo 45xx Gen9バックプレーンエキスパンダー上のエンクロージャーファームウェアをアップグレードするサプリメンタルアップデート / オンラインROMフラッシュSmartコンポーネント"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Supplemental Update / Online ROM Flash Component for Linux &ndash; HPE Apollo 45xx Gen9 Backplane Expander Firmware</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;2.51<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 2.50<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 2.50<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Drive may show up&nbsp;missing after a system reboot.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"},{"lang":"ja","x_late":"<p><strong>提供名:<br />\n     </strong>サプリメンタルアップデート / オンラインROMフラッシュコンポーネントfor Linux - HPE Apollo 45xx Gen9バックプレーンエキスパンダーファームウェア</p>\n\n<p><strong>リリースバージョンおよび/または日付:</strong><br />\n     2.51<br />\n<br />\n<strong>最新の推奨またはクリティカルバージョン:</strong><br />\n     2.50<br />\n<br />\n<strong>前のファームウェアバージョン:</strong><br />\n     2.50<br />\n<br />\n<strong>ファームウェアの関連性:</strong><br />\n     なし        <br />\n<br />\n<strong>改善点/新しい機能：</strong></p>\n\n<ul>\n\t<li>なし\n        </li>\n</ul>\n\n<p><strong>修正された問題点：</strong></p>\n\n<ul>\n\t<li>システムの再起動後にドライブが表示されない場合があります。</li>\n</ul>\n\n<p><strong>既知の問題点:</strong><br />\n     なし        </p>\n"}],"files":[{"bytes":"5377642","datemodified":"2020-03-16T19:04:04","file_list":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-7bdfcd246b-2.51-1.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7bdfcd246b-2.51-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7bdfcd246b-2.51-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7bdfcd246b-2.51-1.1/CP043497.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7bdfcd246b-2.51-1.1/firmware-Release-2.51-build-000.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7bdfcd246b-2.51-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7bdfcd246b-2.51-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7bdfcd246b-2.51-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP043497.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP043497.scexe"],"md5sum":"1f0e684c43f5e352d1df34f044275fc2","name":"firmware-smartarray-7bdfcd246b-2.51-1.1.x86_64.rpm","release":"2020-03-16T00:00:00","revision":"1","sha1sum":"1916ac6c34133ea7e2028521698843609a244da3","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.51"}],"id":{"product":"e73b53ae478842daa9ba4db7eebbb5d9","version":"3fb68ea1e7c04c4fa5085d897add38e6"},"installation":{"command":"CP038041.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><u>Please&nbsp;un-plug and re-plug the power cord to the server for firmware upgrade from version 1.03&nbsp;or earlier to take effect.</u></p>\n\n<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong><em>Updating firmware with rpm installed:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>Install the firmware rpm using the command:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li>\n\t<li>The CP038041.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-7bdfcd246b-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above&nbsp;</li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./ CP038041.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-7bdfcd246b-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><strong><em>Updating firmware without installing the rpm:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-7bdfcd246b-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-7bdfcd246b-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant</u></a>&nbsp;on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li>\n\t<li>Run launch_sum.sh script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><u>バージョン1.03以前からのファームウェアアップグレードを有効にするために、サーバーの電源コードを1度抜いて、再度挿してください。</u></p>\n\n<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p><strong><em>rpmインストールによるファームウェアのアップデート:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>コマンドを使用して、ファームウェアrpmをインストールします:  <em>rpm -ivh <rpm_filename>。  </em>これは、'/usr/lib/x86_64-linux-gnu' の場所へrpmの内容を解凍します。</li>\n\t<li>CP038041.scexeスクリプトは'scexe-compat'フォルダーにあります。'hp-firmware-smartarray-7bdfcd246b-*' フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます:\n\t<ul>\n\t\t<li>./ CP038041.scexe（'/usr/lib/x86_64-linux-gnu/scexe-compat'で実行）（または）</li>\n\t\t<li><em>./hpsetup</em> ('/usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-7bdfcd246b-*'で実行)</li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド: <em>rpm -e <rpm_package_name></em>（'.rpm' 拡張子の付いていないrpmファイル名）を実行します。</li>\n</ul>\n\n<p><strong><em>rpmのインストールなしでのファームウェアのアップデート:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。 <em>rpm2cpio <rpm_filename>.rpm | cpio -id.  </em>これは、現在のディレクトリの‘usr’フォルダーへrpmの内容を抽出します。</li>\n\t<li>'usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-7bdfcd246b-*'に移動し、ファームウェアをアップデートするために<em>./setup</em>を実行します。'hp-firmware-smartarray-7bdfcd246b-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p><strong><em>追加情報:</em></strong></p>\n\n<p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を解凍するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p> </p>\n\n<p><strong>Smart Update Managerを使用するには Service Pack for ProLiant から以下の手順に従ってください:</strong><br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant</u></a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/SPP20xxxxx/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン:</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>アップデートに必要なファームウェアをSPP20xxxxx/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにあるlaunch_sum.shスクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Supplemental Update / Online ROM Flash Component for Linux (x64) – HPE Apollo 45xx Gen9 Backplane Expander Firmware "},{"lang":"ja","x_late":"サプリメンタルアップデート / オンラインROMフラッシュコンポーネント for Linux (x64) - HPE Apollo 45xx Gen9バックプレーンエキスパンダーファームウェア "}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_operating_systems":[{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-05-02T14:37:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Drive may show up&nbsp;missing after a system reboot.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Drive may show up&nbsp;missing after a system reboot.</p>\n\n<p>Please reference Customer Advisory a00098241en_us</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"Carbondale14","value":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"key":"Carbondale14","value":"<p>HPE Apollo 4520 Gen9 Chassis</p>\n"},{"key":"Carbondale14","value":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>\n"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"}],"sw_keys":[{"name":"HP Apollo 4530","sw_key_expectedpath":"firmware:sd:sasexpander"},{"name":"HP Apollo 4520","sw_key_expectedpath":"firmware:sd:sasexpander"},{"name":"HP Apollo 4510","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000JFJTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGNSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-304a464a5448","Version":"HPD4"},{"DeviceName":"MM002000JWCNF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGNSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304d-3230-3030-304a57434e46","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MM1000JFJTH and MM002000JWCNF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MM1000JFJTH and MM002000JWCNF Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3551088","datemodified":"2021-07-25T17:25:10","file_list":["cp048626.xml","cpqsetup.exe","payload.json","SAVGNSD4.rel","setup.dll"],"md5sum":"ac66ba31081b8009d2c02b54e12c6698","name":"cp048626.exe","release":"2021-07-25T17:18:14","revision":"0","sha1sum":"63d7a54ac6c3ece2fccef30cad4598077269d64f","size":"3MB","target_guids":["002340a5-4d00-314d-3030-304a464a5448","4d2340a5-304d-3230-3030-304a57434e46"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"05aa24e5db0c41fc91f79deb60685a31","version":"5702fac0a5bb4870aaed71fec0392142"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MM1000JFJTH and MM002000JWCNF Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MM1000JFJTH","target_guid":"002340a5-4d00-314d-3030-304a464a5448","type":"sas"},{"id":"MM002000JWCNF","target_guid":"4d2340a5-304d-3230-3030-304a57434e46","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T13:34:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MM002000JWCNF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MM1000JFJTH","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCD6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c38303047","Version":"GPK3"},{"DeviceName":"KCD6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c31543630","Version":"GPK3"},{"DeviceName":"KCD6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c33543230","Version":"GPK3"},{"DeviceName":"KCD6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c36543430","Version":"GPK3"},{"DeviceName":"KCD6XVUL12T8","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c31325438","Version":"GPK3"},{"DeviceName":"KCD6XLUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c39363047","Version":"GPK3"},{"DeviceName":"KCD6XLUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c31543932","Version":"GPK3"},{"DeviceName":"KCD6XLUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c33543834","Version":"GPK3"},{"DeviceName":"KCD6XLUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c37543638","Version":"GPK3"},{"DeviceName":"KCD6XLUL15T3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c31355433","Version":"GPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。KCD6XVUL800G、KCD6XVUL1T60、KCD6XVUL3T20、KCD6XVUL6T40、KCD6XVUL12T8、KCD6XLUL960G、KCD6XLUL1T92、KCD6XLUL3T84、KCD6XLUL7T68、KCD6XLUL15T3"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for&nbsp;VMware ESXi - &nbsp;KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3 Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp; GPK3</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>\n"}],"files":[{"bytes":"18438442","datemodified":"2021-08-30T06:40:45","file_list":["/CP049279_BUILD_1.data","/CP049279.vmexe","/CP049279.vmexe64","/CP049279.vmfile","/CP049279_VMw.zip","/CP049279.xml","/payload.json","/CP049279_VMw.zip/index.xml","/CP049279_VMw.zip/vendor-index.xml","/CP049279_VMw.zip/metadata.zip","/CP049279_VMw.zip/vib20/CP049279/HPE_bootbank_CP049279_GPK3.1-7.0.0.15843807.vib","/CP049279_VMw.zip/metadata.zip/vendor-index.xml","/CP049279_VMw.zip/metadata.zip/vmware.xml","/CP049279_VMw.zip/metadata.zip/vibs/CP049279-667443216068728449.xml","/CP049279_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049279_GPK3.1-7.0.0.15843807.xml"],"md5sum":"2190c4b78c7dedc1579b34e93c46eb1a","name":"CP049279.zip","release":"2021-08-30T06:35:46","revision":"0","sha1sum":"4a07b63d02b7da750ed7417623bf225778f631d9","size":"17MB","target_guids":["002340a5-434b-3644-5856-554c38303047","002340a5-434b-3644-5856-554c31543630","002340a5-434b-3644-5856-554c33543230","002340a5-434b-3644-5856-554c36543430","002340a5-434b-3644-5856-554c31325438","002340a5-434b-3644-584c-554c39363047","002340a5-434b-3644-584c-554c31543932","002340a5-434b-3644-584c-554c33543834","002340a5-434b-3644-584c-554c37543638","002340a5-434b-3644-584c-554c31355433"],"type_of_change":"1","version":"GPK3","vib_list":[{"name":"CP049279","version":"GPK3.1-7.0.0.15843807"}]}],"id":{"product":"92d52e2161c24f8f9ff633da842f814c","version":"e877e5f61b494a18b3c6bd3ebc25bbf4"},"installation":{"command":"CP042960.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3 Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - KCD6XVUL800G、KCD6XVUL1T60、KCD6XVUL3T20、KCD6XVUL6T40、KCD6XVUL12T8、KCD6XLUL960G、KCD6XLUL1T92、KCD6XLUL3T84、KCD6XLUL7T68、KCD6XLUL15T3ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"KCD6XLUL7T68","target_guid":"002340a5-434b-3644-584c-554c37543638","type":"nvme"},{"id":"KCD6XVUL6T40","target_guid":"002340a5-434b-3644-5856-554c36543430","type":"nvme"},{"id":"KCD6XVUL1T60","target_guid":"002340a5-434b-3644-5856-554c31543630","type":"nvme"},{"id":"KCD6XVUL800G","target_guid":"002340a5-434b-3644-5856-554c38303047","type":"nvme"},{"id":"KCD6XVUL3T20","target_guid":"002340a5-434b-3644-5856-554c33543230","type":"nvme"},{"id":"KCD6XVUL12T8","target_guid":"002340a5-434b-3644-5856-554c31325438","type":"nvme"},{"id":"KCD6XLUL960G","target_guid":"002340a5-434b-3644-584c-554c39363047","type":"nvme"},{"id":"KCD6XLUL1T92","target_guid":"002340a5-434b-3644-584c-554c31543932","type":"nvme"},{"id":"KCD6XLUL3T84","target_guid":"002340a5-434b-3644-584c-554c33543834","type":"nvme"},{"id":"KCD6XLUL15T3","target_guid":"002340a5-434b-3644-584c-554c31355433","type":"nvme"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-16T10:21:13","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This Firmware release address below&nbsp;fixes and additional features:</p>\n\n<ul>\n\t<li>FW Transfer Fix</li>\n\t<li>Drive Failure Fix</li>\n\t<li>Power Loss Protection</li>\n\t<li>FW Download Fix</li>\n\t<li>Reset Fix</li>\n\t<li>Shutdown fix</li>\n\t<li>PCIe Improvement</li>\n\t<li>Random Write Improvement</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"KCD6XVUL800G","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XLUL7T68","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XLUL3T84","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XLUL960G","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XVUL12T8","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XLUL15T3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XVUL6T40","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XVUL3T20","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XVUL1T60","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XLUL1T92","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GXAWE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304758415745","Version":"HPG1"},{"DeviceName":"VK000480GXAWK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-30475841574b","Version":"HPG1"},{"DeviceName":"VK000960GXAWL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-30475841574c","Version":"HPG1"},{"DeviceName":"VK001920GXAWN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-30475841574e","Version":"HPG1"},{"DeviceName":"VK003840GXAWP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304758415750","Version":"HPG1"},{"DeviceName":"VK007680GXAWQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-304758415751","Version":"HPG1"},{"DeviceName":"MK000480GXAWF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304758415746","Version":"HPG1"},{"DeviceName":"MK000960GXAXB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304758415842","Version":"HPG1"},{"DeviceName":"MK001920GXAWR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304758415752","Version":"HPG1"},{"DeviceName":"MK003840GXAWT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-304758415754","Version":"HPG1"},{"DeviceName":"VR000240GXBBL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3234-30475842424c","Version":"HPG1"},{"DeviceName":"MR000480GXBGH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3438-304758424748","Version":"HPG1"},{"DeviceName":"MR000960GXBGK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3936-30475842474b","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK000240GXAWE, VK000480GXAWK, VK000960GXAWL, VK001920GXAWN, VK003840GXAWP, VK007680GXAWQ, MK000480GXAWF, MK000960GXAXB, MK001920GXAWR, MK003840GXAWT, VR000240GXBBL, MR000480GXBGH and MR000960GXBGK"},{"lang":"ja","x_late":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VK000240GXAWE、VK000480GXAWK、VK000960GXAWL、VK001920GXAWN、VK003840GXAWP、VK007680GXAWQ、MK000480GXAWF、MK000960GXAXB、MK001920GXAWR、MK003840GXAWT、VR000240GXBBL、MR000480GXBGH、およびMR000960GXBGK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;-&nbsp;VK000240GXAWE, VK000480GXAWK, VK000960GXAWL, VK001920GXAWN, VK003840GXAWP, VK007680GXAWQ, MK000480GXAWF, MK000960GXAXB, MK001920GXAWR, MK003840GXAWT, VR000240GXBBL, MR000480GXBGH and MR000960GXBGK&nbsp; Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4734656","datemodified":"2021-07-27T15:54:42","file_list":["cp049159.xml","cpqsetup.exe","M5300AG1.rel","payload.json","setup.dll"],"md5sum":"9c47eaab0a878da81af4d7198ef04c93","name":"cp049159.exe","release":"2021-07-27T15:47:06","revision":"0","sha1sum":"ed77f775efe66739b75801e7cff410ec9ed5160a","size":"4MB","target_guids":["562340a5-304b-3030-3234-304758415745","562340a5-304b-3030-3438-30475841574b","562340a5-304b-3030-3936-30475841574c","562340a5-304b-3130-3932-30475841574e","562340a5-304b-3330-3834-304758415750","562340a5-304b-3730-3638-304758415751","4d2340a5-304b-3030-3438-304758415746","4d2340a5-304b-3030-3936-304758415842","4d2340a5-304b-3130-3932-304758415752","4d2340a5-304b-3330-3834-304758415754","562340a5-3052-3030-3234-30475842424c","4d2340a5-3052-3030-3438-304758424748","4d2340a5-3052-3030-3936-30475842474b"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"3e81763b3821481db4fe370a0e06c011","version":"dc8bd0a7ea0e4e7da3154af323d7bebf"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"http://www.hpe.com/jp/servers/spp_dl　\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK000240GXAWE, VK000480GXAWK, VK000960GXAWL, VK001920GXAWN, VK003840GXAWP, VK007680GXAWQ, MK000480GXAWF, MK000960GXAXB, MK001920GXAWR, MK003840GXAWT, VR000240GXBBL, MR000480GXBGH and MR000960GXBGK  Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - VK000240GXAWE、VK000480GXAWK、VK000960GXAWL、VK001920GXAWN、VK003840GXAWP、VK007680GXAWQ、MK000480GXAWF、MK000960GXAXB、MK001920GXAWR、MK003840GXAWT、VR000240GXBBL、MR000480GXBGH、およびMR000960GXBGKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MR000960GXBGK","target_guid":"4d2340a5-3052-3030-3936-30475842474b","type":"sata"},{"id":"MR000480GXBGH","target_guid":"4d2340a5-3052-3030-3438-304758424748","type":"sata"},{"id":"VR000240GXBBL","target_guid":"562340a5-3052-3030-3234-30475842424c","type":"sata"},{"id":"MK003840GXAWT","target_guid":"4d2340a5-304b-3330-3834-304758415754","type":"sata"},{"id":"MK001920GXAWR","target_guid":"4d2340a5-304b-3130-3932-304758415752","type":"sata"},{"id":"MK000960GXAXB","target_guid":"4d2340a5-304b-3030-3936-304758415842","type":"sata"},{"id":"MK000480GXAWF","target_guid":"4d2340a5-304b-3030-3438-304758415746","type":"sata"},{"id":"VK007680GXAWQ","target_guid":"562340a5-304b-3730-3638-304758415751","type":"sata"},{"id":"VK003840GXAWP","target_guid":"562340a5-304b-3330-3834-304758415750","type":"sata"},{"id":"VK000960GXAWL","target_guid":"562340a5-304b-3030-3936-30475841574c","type":"sata"},{"id":"VK000480GXAWK","target_guid":"562340a5-304b-3030-3438-30475841574b","type":"sata"},{"id":"VK000240GXAWE","target_guid":"562340a5-304b-3030-3234-304758415745","type":"sata"},{"id":"VK001920GXAWN","target_guid":"562340a5-304b-3130-3932-30475841574e","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-27T15:42:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>The updates were included in a regularly scheduled 5300 maintenance release. This firmware has a security version upgrade to include TCGe SKUs and prevent a downloading of a back level firmware version of HPG0 after upgrading to HPG1.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK001920GXAWR","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK003840GXAWT","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VR000240GXBBL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GXAWP","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MR000960GXBGK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GXAWK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GXAXB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GXAWE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GXAWL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GXAWN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK007680GXAWQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GXAWF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MR000480GXBGH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO0400JFFCF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3430-304a46464346","Version":"HPD9"},{"DeviceName":"MO0800JFFCH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3830-304a46464348","Version":"HPD9"},{"DeviceName":"MO1600JFFCK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304a4646434b","Version":"HPD9"},{"DeviceName":"MO3200JFFCL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-334f-3230-304a4646434c","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MO0400JFFCF, MO0800JFFCH, MO1600JFFCK and MO3200JFFCL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MO0400JFFCF, MO0800JFFCH, MO1600JFFCK and MO3200JFFCL Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD9</p>\n\n<p><strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD8</p>\n\n<p><strong>Previous Version of Firmware:<br />\n&nbsp; &nbsp; &nbsp;</strong> HPD8</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Enhancements/New Features:&nbsp;</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p>\n"}],"files":[{"bytes":"3213888","datemodified":"2021-07-25T21:25:52","file_list":["cp048661.xml","cpqsetup.exe","GP1635D9.rel","payload.json","setup.dll"],"md5sum":"1b43bd1d2e775b57b697604f87e2002b","name":"cp048661.exe","release":"2021-07-25T21:19:04","revision":"0","sha1sum":"05812158e88bb2d1ad973df2c6e2e182d2de46a9","size":"3MB","target_guids":["002340a5-4d00-304f-3430-304a46464346","002340a5-4d00-304f-3830-304a46464348","002340a5-4d00-314f-3630-304a4646434b","002340a5-4d00-334f-3230-304a4646434c"],"type_of_change":"1","version":"HPD9"}],"id":{"product":"82cd9f1b504a4d3798c759e1d18439aa","version":"1c449022ee8141dcbfc8d60afce022a6"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MO0400JFFCF, MO0800JFFCH, MO1600JFFCK and MO3200JFFCL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MO0400JFFCF、MO0800JFFCH、MO1600JFFCK、およびMO3200JFFCLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MO1600JFFCK","target_guid":"002340a5-4d00-314f-3630-304a4646434b","type":"sas"},{"id":"MO0400JFFCF","target_guid":"002340a5-4d00-304f-3430-304a46464346","type":"sas"},{"id":"MO0800JFFCH","target_guid":"002340a5-4d00-304f-3830-304a46464348","type":"sas"},{"id":"MO3200JFFCL","target_guid":"002340a5-4d00-334f-3230-304a4646434c","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-17T05:54:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MO0800JFFCH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO3200JFFCL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO0400JFFCF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO1600JFFCK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWFVC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SEhD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3830-304a57465643","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: EG001800JWFVC"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EG001800JWFVC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG001800JWFVC Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp; </strong>None</p>\n"}],"files":[{"bytes":"16256592","datemodified":"2021-08-31T05:56:21","file_list":["/CP048253_BUILD_2.data","/CP048253.vmexe","/CP048253.vmexe64","/CP048253.vmfile","/CP048253_VMw.zip","/CP048253.xml","/payload.json","/CP048253_VMw.zip/index.xml","/CP048253_VMw.zip/vendor-index.xml","/CP048253_VMw.zip/metadata.zip","/CP048253_VMw.zip/vib20/CP048253/HPE_bootbank_CP048253_HPD4.2-7.0.0.15843807.vib","/CP048253_VMw.zip/metadata.zip/vendor-index.xml","/CP048253_VMw.zip/metadata.zip/vmware.xml","/CP048253_VMw.zip/metadata.zip/vibs/CP048253--7086440309689431666.xml","/CP048253_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048253_HPD4.2-7.0.0.15843807.xml"],"md5sum":"94529813da19c3f61d025358387b4376","name":"CP048253.zip","release":"2021-08-31T05:51:35","revision":"0","sha1sum":"d613aafc3c98840ddab1641f01a4aefb172b0a25","size":"15MB","target_guids":["452340a5-3047-3130-3830-304a57465643"],"type_of_change":"1","version":"HPD4","vib_list":[{"name":"CP048253","version":"HPD4.2-7.0.0.15843807"}]}],"id":{"product":"f651d51d32bf48dca96b23a2b4fb67f4","version":"4fd3ba946e1c4a4e9c949c20259cc4c0"},"installation":{"command":"CP040556.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EG001800JWFVC Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EG001800JWFVC ライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG001800JWFVC","target_guid":"452340a5-3047-3130-3830-304a57465643","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-02T08:04:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>A low-probability, high severity corner case of sustained outer-diameter activity with emergency power off when heads are at the outer diameter prevented heads from parking/latching properly on a few drives in the field.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001800JWFVC","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains drivers for the HPE QLogic FastLinQ 10/25/50 GbE Multifunction Adapters running under VMware vSphere 7.0."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains the following drivers:</p>\n\n<ul>\n\t<li>qedf, version 2.2.62.0</li>\n\t<li>qedrntv, version 3.40.35.0</li>\n\t<li>qedentv, version 3.40.36.0</li>\n\t<li>qedi, version 2.19.59.0</li>\n</ul>\n"}],"files":[{"bytes":"5241769","datemodified":"2021-08-11T13:37:36","file_list":["/cp047113.xml","/MRVL-E4-CNA-Driver-Bundle_5.0.269.0-1OEM.700.1.0.15843807_18150440.zip","/MRVL-E4-CNA-Driver-Bundle_5.0.269.0-1OEM.700.1.0.15843807_18150440.zip/index.xml","/MRVL-E4-CNA-Driver-Bundle_5.0.269.0-1OEM.700.1.0.15843807_18150440.zip/vendor-index.xml","/MRVL-E4-CNA-Driver-Bundle_5.0.269.0-1OEM.700.1.0.15843807_18150440.zip/metadata.zip","/MRVL-E4-CNA-Driver-Bundle_5.0.269.0-1OEM.700.1.0.15843807_18150440.zip/vib20/qedrntv/QLC_bootbank_qedrntv_3.40.35.0-1OEM.700.1.0.15843807.vib","/MRVL-E4-CNA-Driver-Bundle_5.0.269.0-1OEM.700.1.0.15843807_18150440.zip/vib20/qedentv/QLC_bootbank_qedentv_3.40.36.0-1OEM.700.1.0.15843807.vib","/MRVL-E4-CNA-Driver-Bundle_5.0.269.0-1OEM.700.1.0.15843807_18150440.zip/vib20/qedf/QLC_bootbank_qedf_2.2.62.0-1OEM.700.1.0.15843807.vib","/MRVL-E4-CNA-Driver-Bundle_5.0.269.0-1OEM.700.1.0.15843807_18150440.zip/vib20/qedi/QLC_bootbank_qedi_2.19.59.0-1OEM.700.1.0.15843807.vib","/MRVL-E4-CNA-Driver-Bundle_5.0.269.0-1OEM.700.1.0.15843807_18150440.zip/metadata.zip/vendor-index.xml","/MRVL-E4-CNA-Driver-Bundle_5.0.269.0-1OEM.700.1.0.15843807_18150440.zip/metadata.zip/vmware.xml","/MRVL-E4-CNA-Driver-Bundle_5.0.269.0-1OEM.700.1.0.15843807_18150440.zip/metadata.zip/vibs/qedrntv-4903926188448242609.xml","/MRVL-E4-CNA-Driver-Bundle_5.0.269.0-1OEM.700.1.0.15843807_18150440.zip/metadata.zip/vibs/qedentv-2923081051346156035.xml","/MRVL-E4-CNA-Driver-Bundle_5.0.269.0-1OEM.700.1.0.15843807_18150440.zip/metadata.zip/vibs/qedf-5010612161522064556.xml","/MRVL-E4-CNA-Driver-Bundle_5.0.269.0-1OEM.700.1.0.15843807_18150440.zip/metadata.zip/vibs/qedi--3088540654211498250.xml","/MRVL-E4-CNA-Driver-Bundle_5.0.269.0-1OEM.700.1.0.15843807_18150440.zip/metadata.zip/bulletins/MRVL-E4-CNA-Driver-Bundle_5.0.269.0-1OEM.700.1.0.15843807.xml"],"md5sum":"7ab94eacf0292801949f57f329bf0e72","name":"cp047113.zip","release":"2021-08-11T13:34:14","revision":"0","sha1sum":"316063cd4363e4fac2f8e1e0c7b6a57cbf544cba","size":"4MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec6a25bd0a","20a6e8e4-bf33-4c71-a6bf-d9ec89e84beb","20a6e8e4-bf33-4c71-a6bf-d9ec143d8daa","20a6e8e4-bf33-4c71-a6bf-d9ecd558d67b","20a6e8e4-bf33-4c71-a6bf-d9ec5685b43a"],"type_of_change":"0","version":"2021.09.04","vib_list":[{"name":"qedrntv","version":"3.40.35.0-1OEM.700.1.0.15843807"},{"name":"qedentv","version":"3.40.36.0-1OEM.700.1.0.15843807"},{"name":"qedf","version":"2.2.62.0-1OEM.700.1.0.15843807"},{"name":"qedi","version":"2.19.59.0-1OEM.700.1.0.15843807"}]}],"id":{"product":"70da4993d44e45a79517f24aa5d41862","version":"9126830544154b17bd7acfe31aa98c6e"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバーにUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic FastLinQ 10/25/50 GbE Multifunction Driver for VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"8070","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021d","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021f","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0074","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770074","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0073","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770073","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-807015900220","type":"pci","ven":"1077"},{"dev":"8070","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8070159002bd","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0070","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770070","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0069","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770069","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0068","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770068","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0071","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770071","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0072","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770072","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021a","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021b","type":"pci","ven":"1077"},{"dev":"8090","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8090159002bd","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-809015900220","type":"pci","ven":"1077"},{"dev":"8090","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80901590021d","type":"pci","ven":"1077"},{"dev":"8090","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80901590021f","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product addresses a Purple Screen Of Death (PSOD) seen on systems operating in a complicated VLAN environment.</p>\n"},{"curr_enhancements_x_late":"<p>This product enhances reliability via adding support for communication between firmware and drivers.</p>\n","curr_fixes_x_late":"<p>This product corrects an issue Vmkernel logs are flooding while running the traffic.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"qedf:2.2.62.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qedentv:3.40.36.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"MRVL-E4-CNA-Driver-Bundle:5.0.269.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver.component:vmware:zip"},{"name":"qedrntv:3.40.35.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qedi:2.19.59.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MT001600KWHAC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPS1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3130-3630-304b57484143","Version":"HPS1"},{"DeviceName":"MT003200KWHAD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPS1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3330-3230-304b57484144","Version":"HPS1"},{"DeviceName":"MT006400KWHAE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPS1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3630-3430-304b57484145","Version":"HPS1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MT001600KWHAC, MT003200KWHAD and MT006400KWHAE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for Linux (x64) - &nbsp;MT001600KWHAC, MT003200KWHAD and MT006400KWHAE Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPS1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK1<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK1<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>\n"}],"files":[{"bytes":"6879017","datemodified":"2021-07-25T12:37:54","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8e8ddc5265-HPS1-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e8ddc5265-HPS1-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e8ddc5265-HPS1-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e8ddc5265-HPS1-6.1/CP048504.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e8ddc5265-HPS1-6.1/HPS1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e8ddc5265-HPS1-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e8ddc5265-HPS1-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e8ddc5265-HPS1-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e8ddc5265-HPS1-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048504.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048504.scexe"],"md5sum":"2e977b5079925bfb41ae222165e0f86a","name":"firmware-hdd-8e8ddc5265-HPS1-6.1.x86_64.rpm","release":"2021-07-25T12:24:05","revision":"0","sha1sum":"7a38bc7b697994d929610d9093e5cec2e3e5eee2","size":"6MB","target_guids":["4d2340a5-3054-3130-3630-304b57484143","4d2340a5-3054-3330-3230-304b57484144","4d2340a5-3054-3630-3430-304b57484145"],"type_of_change":"1","version":"HPS1"}],"id":{"product":"0d61f1ea72cf4d4991d4093a05f8808a","version":"c713cff99aa648eba00a06f0d88a258f"},"installation":{"command":"CP040131.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - MT001600KWHAC, MT003200KWHAD and MT006400KWHAE Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - MT001600KWHAC、MT003200KWHAD、およびMT006400KWHAEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MT006400KWHAE","target_guid":"4d2340a5-3054-3630-3430-304b57484145","type":"nvme"},{"id":"MT003200KWHAD","target_guid":"4d2340a5-3054-3330-3230-304b57484144","type":"nvme"},{"id":"MT001600KWHAC","target_guid":"4d2340a5-3054-3130-3630-304b57484143","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T05:48:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MT003200KWHAD","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT001600KWHAC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT006400KWHAE","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800213","languages":[{"lang":"fr","x_late":"Logiciel - Lights-Out Management"},{"lang":"en","x_late":"Software - Lights-Out Management"},{"lang":"cn","x_late":"软件 - Lights-Out Management"},{"lang":"tw","x_late":"軟體 ─ Lights-Out 管理"},{"lang":"de","x_late":"Software - LOM (Lights-Out Management)"},{"lang":"ko","x_late":"소프트웨어 - Lights-Out 관리"},{"lang":"ja","x_late":"ソフトウェア - Lights-Outマネジメント"},{"lang":"es","x_late":"Software - Administración de apagado eléctrico"}]}],"description":[{"lang":"en","x_late":"HPE Lights-Out Online Configuration utility is a command line utility used to configure ProLiant Integrated Lights-Out processor (iLO) from within the Linux operating system without requiring a reboot of the server."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]}],"documentation":[],"files":[{"bytes":"60457","datemodified":"2020-10-15T06:43:56","file_list":["./sbin/hponcfg","./usr/lib64/libhponcfg64.so","./usr/share/doc/hponcfg","./usr/share/doc/hponcfg/readme.txt","./usr/share/smartupdate/hponcfg/component.xml"],"md5sum":"3e991c52d2e72cb58e751f64774c0b32","name":"hponcfg-5.6.0-0.x86_64.rpm","release":"2020-10-15T06:39:06","revision":"0","sha1sum":"620aa256a415de5faaf1f9fa5e1f4464ccffd7b3","size":"59KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccecbdbe8"],"type_of_change":"1","version":"5.6.0-0"}],"id":{"product":"db808d6aa2e24648bcc5e3f46d635b1a","version":"640d4499d8c64ee79f546d439f55961d"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>If a previous version of the Hponcfg utility has been installed, it must be removed before this package can be installed. To remove the previous version of the package, type the following :</p>\n\n<ul>\n\t<li>rpm -e hponcfg</li>\n</ul>\n\n<p>To install the package, type:</p>\n\n<ul>\n\t<li>rpm -ivh hponcfg-x.x.x.x86_64.rpm</li>\n</ul>\n\n<p>After installation, the executable for hponcfg utility can be found under the directory /sbin.</p>\n"},{"lang":"ja","x_late":"<p>システム管理者（root）としてログインし、RPMをご使用のハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</p>\n\n<p>Hponcfgユーティリティの以前のバージョンをインストールしている場合は、削除しておかないと、このパッケージをインストールできません。パッケージの以前のバージョンを削除するには、次のように入力します：</p>\n\n<ul>\n\t<li>rpm -e hponcfg</li>\n</ul>\n\n<p>パッケージをインストールするには、次のようにタイプします。</p>\n\n<ul>\n\t<li>rpm -ivh hponcfg-x.x.x.x86_64.rpm</li>\n</ul>\n\n<p>インストール後は、/sbinディレクトリにhponcfgの実行可能ファイルが見つかります。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Lights-Out Online Configuration Utility for Linux (AMD64/EM64T)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"3307","subdev":"3309","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3307103c3309","type":"pci","ven":"103c"},{"dev":"3306","subdev":"3309","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3306103c3309","type":"pci","ven":"103c"},{"dev":"3302","subdev":"3309","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3302103c3309","type":"pci","ven":"103c"},{"dev":"3300","subdev":"3309","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3300103c3309","type":"pci","ven":"103c"},{"dev":"3308","subdev":"3309","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3308103c3309","type":"pci","ven":"103c"},{"dev":"3301","subdev":"3309","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3301103c3309","type":"pci","ven":"103c"},{"dev":"3300","subdev":"330e","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3300103c330e","type":"pci","ven":"103c"},{"dev":"3301","subdev":"330e","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3301103c330e","type":"pci","ven":"103c"},{"dev":"3302","subdev":"330e","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3302103c330e","type":"pci","ven":"103c"},{"dev":"3306","subdev":"330e","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3306103c330e","type":"pci","ven":"103c"},{"dev":"3307","subdev":"330e","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3307103c330e","type":"pci","ven":"103c"},{"dev":"3308","subdev":"330e","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3308103c330e","type":"pci","ven":"103c"},{"id":"5219994","target_guid":"","type":"other"},{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3306103c3381","type":"pci","ven":"103C"},{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3307103c3381","type":"pci","ven":"103C"},{"dev":"3308","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3308103c3381","type":"pci","ven":"103C"},{"dev":"3300","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3300103c3381","type":"pci","ven":"103C"},{"dev":"3301","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3301103c3381","type":"pci","ven":"103C"},{"dev":"3302","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3302103c3381","type":"pci","ven":"103C"},{"dev":"3307","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3307159000e4","type":"pci","ven":"103C"},{"dev":"3306","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3306159000e4","type":"pci","ven":"103C"},{"id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","target_guid":"","type":"other"},{"dev":"3307","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"10","minor":"0","name":"SUSE LINUX Enterprise Server 10 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"5","minor":"0","name":"Red Hat Enterprise Linux 5 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-06-27T08:36:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Updated the OpenSSL API calls to support Host&#39;s OpenSSL FIPS mode.</p>\n"},{"curr_enhancements_x_late":"<p>Updated product name to HPE Lights-Out Online Configuration Utility for Linux (AMD64/EM64T).</p>\n","curr_fixes_x_late":"<p>Fixed an issue where HPONCFG was not able to detect openssl library when&nbsp;multiple 64-bit openssl installed.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"Carbondale14","value":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>\n"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"A16","value":"HP ProLiant DL585 G7 Server"},{"key":"I25","value":"HP ProLiant BL680c G7 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"P78","value":"HP ProLiant ML310e Gen8 v2 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I25","value":"HP ProLiant BL620c G7 Server"},{"key":"U24","value":"HPE ProLiant XL2x260w Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"P65","value":"HP ProLiant DL580 G7 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"","value":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4520 Gen9 Chassis</p>\n"},{"key":"P75","value":"HP ProLiant SL270s Gen8 SE Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"A45","value":"HPE XL925g Quad Gen10 Plus EPYC Server"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"A31","value":"HP ProLiant SL4545 G7 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"P83","value":"HP ProLiant SL210t Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P68","value":"HP ProLiant DL360 G7 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P88","value":"HP ProLiant ML10 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"A20","value":"HP ProLiant BL685c G7 Server"},{"key":"P67","value":"HP ProLiant DL380 G7 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"P66","value":"HP ProLiant DL980 G7 Server"},{"key":"P94","value":"HP ProLiant XL220a Gen8 v2 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U51","value":"HPE ProLiant XL920g Gen10 Plus Server"},{"key":"A19","value":"HP ProLiant BL465c G7 Server"},{"key":"A18","value":"HP ProLiant DL385 G7 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"","value":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"J06","value":"HP ProLiant MicroServer Gen8"},{"key":"A48","value":"HPE ProLiant XL215n Gen10 Plus"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I27","value":"HP ProLiant BL460c G7 Server"},{"key":"I28","value":"HP ProLiant BL490c G7 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"},{"key":"I29","value":"HP ProLiant BL2x220c G7 Server"}],"sw_keys":[{"name":"hponcfg","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000GEFNA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRATG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304745464e41","Version":"HPG6"},{"DeviceName":"MB6000GEFNB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRATG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745464e42","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB4000GEFNA and MB6000GEFNB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB4000GEFNA and MB6000GEFNB Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp;</strong> None</p>\n"}],"files":[{"bytes":"17070008","datemodified":"2021-08-26T19:38:32","file_list":["/CP048365_BUILD_2.data","/CP048365.vmexe","/CP048365.vmexe64","/CP048365.vmfile","/CP048365_VMw.zip","/CP048365.xml","/payload.json","/CP048365_VMw.zip/index.xml","/CP048365_VMw.zip/vendor-index.xml","/CP048365_VMw.zip/metadata.zip","/CP048365_VMw.zip/vib20/CP048365/HPE_bootbank_CP048365_HPG6.2-7.0.0.15843807.vib","/CP048365_VMw.zip/metadata.zip/vendor-index.xml","/CP048365_VMw.zip/metadata.zip/vmware.xml","/CP048365_VMw.zip/metadata.zip/vibs/CP048365--562824061359719919.xml","/CP048365_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048365_HPG6.2-7.0.0.15843807.xml"],"md5sum":"6fbb2b227af99c5099f48a91ca052914","name":"CP048365.zip","release":"2021-08-26T19:32:24","revision":"0","sha1sum":"8cafacc5773c5ffd9ec8303de1df6db9e2c4678c","size":"16MB","target_guids":["002340a5-4d00-3442-3030-304745464e41","002340a5-4d00-3642-3030-304745464e42"],"type_of_change":"1","version":"HPG6","vib_list":[{"name":"CP048365","version":"HPG6.2-7.0.0.15843807"}]}],"id":{"product":"27c04cd9178a40abb16f9409a4957000","version":"ee1feb31b6e0463ba7bdda80d0a17a6d"},"installation":{"command":"CP039421.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB4000GEFNA and MB6000GEFNB Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor ESXi - MB4000GEFNAおよびMB6000GEFNBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB4000GEFNA","target_guid":"002340a5-4d00-3442-3030-304745464e41","type":"sata"},{"id":"MB6000GEFNB","target_guid":"002340a5-4d00-3642-3030-304745464e42","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-07T18:32:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000GEFNA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB6000GEFNB","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The Smart Storage Administrator CLI (SSACLI) is a commandline-based disk configuration program that helps you configure, manage, diagnose, and monitor Smart Array and SmartRAID Controllers and now other storage devices as well, such as host bus adapters (HBAs), Storage controllers, and future devices such as SCSI Express drives, and SAS switch devices."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p>To enter the&nbsp;SSA&nbsp;CLI console type: ssacli</p>\n\n<p>Commands can also be executed from outside the&nbsp;SSA&nbsp;CLI console using the syntax: ssacli</p>\n\n<p>Type &quot;ssacli help&quot; or type &quot;help&quot; at the CLI prompt for usage details.</p>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"8580096","datemodified":"2021-08-11T12:35:09","file_list":["cp047063.xml","cpqsetup.exe","genericmsi.dll","SSACLI52080_X64.msi"],"md5sum":"c928b988323b98653fe6fd1ce1ac81c3","name":"cp047063.exe","release":"2021-08-11T12:33:04","revision":"0","sha1sum":"2a8c182ed82b23db9fe8a86ccf59fd8bb29dc929","size":"8MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec9f015b42"],"type_of_change":"1","version":"5.20.8.0"}],"id":{"product":"01e0939311154208bbd5b8d9e5157a9c","version":"71718698e55e444aada8666924670897"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation. The utility will automatically be installed.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Windows (64 位元) 的 Smart Storage Administrator (智慧型儲存管理員 (SSA)) CLI"},{"lang":"en","x_late":"Smart Storage Administrator (SSA) CLI for Windows 64-bit"},{"lang":"ko","x_late":"Windows 64비트용 스마트 스토리지 관리자(SSA) CLI"},{"lang":"cn","x_late":"64位Windows版Smart Storage Administrator (SSA) CLI"},{"lang":"ja","x_late":"Smart Storage Administrator (SSA) CLI for Windows 64ビット"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-09T05:12:46","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added&nbsp;support&nbsp;to the HPE&nbsp;SR932i-p and SR416-a&nbsp;Gen10+&nbsp;Controllers.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2022 for HPE ProLiant Gen10 and Gen10 Plus platforms only.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U38","value":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"key":"U38","value":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"key":"","value":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U14","value":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4520 Gen9 Chassis</p>\n"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U27","value":"HPE ProLiant XL2x260w Gen9 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>\n"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"","value":"HPE ProLiant ML150 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"","value":"HPE ProLiant XL770f Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"Carbondale14","value":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"ssacli.exe","sw_key_expectedpath":"%ProgramFiles%\\Smart Storage Administrator\\ssacli\\bin"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWEBH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBUGD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a57454248","Version":"HPD5"},{"DeviceName":"EG000300JWEBF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBUGD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57454246","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG000600JWEBH and EG000300JWEBF"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EG000600JWEBHおよびEG000300JWEBF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;EG000600JWEBH and EG000300JWEBF Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3659584","datemodified":"2021-08-25T12:02:22","file_list":["cp049346.xml","cpqsetup.exe","payload.json","setup.dll","STHBUGD5.rel"],"md5sum":"03ab5c70923d2b842f50fc90bf04201e","name":"cp049346.exe","release":"2021-08-25T11:54:05","revision":"0","sha1sum":"37706cde029154ff6cf591d1bc2e16613c5019d1","size":"3MB","target_guids":["452340a5-3047-3030-3630-304a57454248","452340a5-3047-3030-3330-304a57454246"],"type_of_change":"1","version":"HPD5"}],"id":{"product":"4ac05ec48f5041978979616c09c3b9fb","version":"2bef34203faf4c608eb62a09275a5b7a"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/jp/servers/spp_dl\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG000600JWEBH and EG000300JWEBF Drives"},{"lang":"ja","x_late":"オンラインHDD/SDDフラッシュコンポーネントfor Windows (x64) -  EG000600JWEBHおよびEG000300JWEBFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG000300JWEBF","target_guid":"452340a5-3047-3030-3330-304a57454246","type":"sas"},{"id":"EG000600JWEBH","target_guid":"452340a5-3047-3030-3630-304a57454248","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-25T11:50:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG000600JWEBH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG000300JWEBF","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following storage controllers: Smart Array and Smart HBA H240ar, H240nr, H240, H241, H244br, P240nr, P244br, P246br, P440ar, P440, P441, P542D, P741m, P840, P840ar, and  P841"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のストレージコントローラーのファームウェアを提供します。SmartアレイおよびSmart HBA H240ar、H240nr、H240、H241、H244br、P240nr、P244br、P246br、P440ar、P440、P441、P542D、P741m、P840、P840arおよびP841"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Supplemental Update / Online ROM Flash Component for Linux&nbsp;(x64)&nbsp;- Smart Array and Smart HBA H240ar, H240nr, H240, H241, H244br, P240nr, P244br, P246br, P440ar, P440, P441, P542D, P741m, P840, P840ar, and&nbsp;P841<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;7.00</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;6.88<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;6.60(B)</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp; &nbsp; &nbsp;Initial release for Snap4</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"6880714","datemodified":"2019-08-08T19:26:12","file_list":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-ea3138d8e8-7.00-1.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-ea3138d8e8-7.00-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-ea3138d8e8-7.00-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-ea3138d8e8-7.00-1.1/CP039997.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-ea3138d8e8-7.00-1.1/firmware_signed.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-ea3138d8e8-7.00-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-ea3138d8e8-7.00-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-ea3138d8e8-7.00-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP039997.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP039997.scexe"],"md5sum":"84261221942a6dd6bd6898620f460f56","name":"firmware-smartarray-ea3138d8e8-7.00-1.1.x86_64.rpm","release":"2019-08-08T19:14:12","revision":"0","sha1sum":"39fcda2f19ef37d1e40072c4669a59317419dc1f","size":"6MB","target_guids":[],"type_of_change":"1","version":"7.00"}],"id":{"product":"61f59cb79a694ca78cfec9d06ac2ad97","version":"13095de5299a4e97b38dcb58cb035af0"},"installation":{"command":"CP039997.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Smart Array Controller Driver version 3.4.4 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec21fe94e4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"3.4.4-0","description":"HP ProLiant Smart Array Controller Driver version 3.4.4 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Smart Array Controller Driver version 3.4.6 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec21fe94e4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"3.4.6-0","description":"HP ProLiant Smart Array Controller Driver version 3.4.6 or greater is required and should be already active"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActiveIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Smart Array HPCISSS3 Controller Driver version 100.18.2.64 must not be used for firmware update.  Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfd368f11","ServerModel":["*"],"Target_guids":[],"Type":"NE","Version":"100.18.2.64","description":"HPE ProLiant Smart Array HPCISSS3 Controller Driver version 100.18.2.64 must not be used for firmware update.  Update the driver and reboot before attempting firmware update."}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong><em>Updating firmware with rpm installed:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>Install the firmware rpm using the command:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li>\n\t<li>The CP039997.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-ea3138d8e8-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./ CP039997.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-ea3138d8e8-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><strong><em>Updating firmware without installing the rpm:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-ea3138d8e8-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-ea3138d8e8-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li>\n\t<li>Run launch_sum.sh script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Supplemental Update / Online ROM Flash Component for Linux (x64) - Smart Array and Smart HBA H240ar, H240nr, H240, H241, H244br, P240nr, P244br, P246br, P440ar, P440, P441, P542D, P741m, P840, P840ar, and  P841"},{"lang":"ja","x_late":"サプリメンタルアップデート/オンラインROMフラッシュコンポーネントfor Linux（x64）- SmartアレイおよびSmart HBA H240ar、H240nr、H240、H241、H244br、P240nr、P244br、P246br、P440ar、P440、P441、P542D、P741m、P840、P840arおよびP841"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"3239","subdev":"21c3","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c0","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c2","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21BD","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c7","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21bf","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c6","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cb","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21be","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c5","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ca","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c8","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21CD","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cc","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ce","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c1","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-06-29T18:58:49","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Fixes the following Issues</p>\n\n<ul>\n\t<li>SATA drive could stop responding&nbsp; while on HBA mode when non-NCQ commands are executed</li>\n\t<li>Controller could stop responding when upgrading due to the DDR Cache Module exceeding its limitations</li>\n\t<li>SSD Cache module could become disable while upgrading FW</li>\n\t<li>Data from the HPE Smart Drive Backplane could potentially become corrupted if a non-HPE carrier is present</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Add optimization for the iLO communication interface in order to have a more effective mechanism to check for ownership of the communication buffer</p>\n","curr_fixes_x_late":"<ul>\n\t<li>Occasionally&nbsp; the drive will not accept any IO&rsquo;s after running Sanitize command for a period of time due to the FW being out of sync with the drive during that time</li>\n\t<li>Non-HPE drives could report &ldquo;Task Set Full&rdquo; due to the drives reaching the qdepth limit during heavy workload</li>\n\t<li>Raid volume is not discovered due to a bad drive consuming two slots during hotplug</li>\n\t<li>Data could become inaccessible when upgrading from&nbsp;firmware versions prior to 4.5x</li>\n\t<li>The controller could stop responding when executing a SCSI verify command due to a CPU exception</li>\n\t<li>The system could stop communicating due to an I/O command timeout</li>\n\t<li>While on HBA mode, a drive could stop responding due to an early allocated buffer release</li>\n\t<li>A SAS drive WWN is reported inaccuratelyy due to an incorrect report causing the driver to be out of sync with the device</li>\n\t<li>If using a 4G module, the controller could stop responding due to the SSD Cache metadata exceeding its limits during a Backup</li>\n\t<li>SSD Smart Cache module become disabled due to a reduction in usable cache space</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"21be103c","sw_key_expectedpath":"firmware"},{"name":"21CD103c","sw_key_expectedpath":"firmware"},{"name":"21cb103c","sw_key_expectedpath":"firmware"},{"name":"21BD103c","sw_key_expectedpath":"firmware"},{"name":"21c6103c","sw_key_expectedpath":"firmware"},{"name":"21c1103c","sw_key_expectedpath":"firmware"},{"name":"21c5103c","sw_key_expectedpath":"firmware"},{"name":"21cc103c","sw_key_expectedpath":"firmware"},{"name":"21c2103c","sw_key_expectedpath":"firmware"},{"name":"21c8103c","sw_key_expectedpath":"firmware"},{"name":"21c3103c","sw_key_expectedpath":"firmware"},{"name":"21bf103c","sw_key_expectedpath":"firmware"},{"name":"21c7103c","sw_key_expectedpath":"firmware"},{"name":"21ca103c","sw_key_expectedpath":"firmware"},{"name":"21ce103c","sw_key_expectedpath":"firmware"},{"name":"21c0103c","sw_key_expectedpath":"firmware"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000960JWSSQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304a57535351","Version":"HPD8"},{"DeviceName":"VK001920JWSSR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304a57535352","Version":"HPD8"},{"DeviceName":"VK003840JWSST","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304a57535354","Version":"HPD8"},{"DeviceName":"VK007680JWSSU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-304a57535355","Version":"HPD8"},{"DeviceName":"VO015300JWSSV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3330-304a57535356","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK000960JWSSQ, VK001920JWSSR, VK003840JWSST, VK007680JWSSU and VO015300JWSSV"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VK000960JWSSQ、VK001920JWSSR、VK003840JWSST、VK007680JWSSUおよびVO015300JWSSV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - VK000960JWSSQ, VK001920JWSSR, VK003840JWSST, VK007680JWSSU and VO015300JWSSV&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3305440","datemodified":"2021-07-25T21:46:57","file_list":["cp048665.xml","cpqsetup.exe","GPM1643SAMD8.rel","payload.json","setup.dll"],"md5sum":"8d0d1c5d4eeb9b8fec78895b8a7d2999","name":"cp048665.exe","release":"2021-07-25T21:38:04","revision":"0","sha1sum":"55767bd23f6b31034b18be934debe48d18c710c4","size":"3MB","target_guids":["562340a5-304b-3030-3936-304a57535351","562340a5-304b-3130-3932-304a57535352","562340a5-304b-3330-3834-304a57535354","562340a5-304b-3730-3638-304a57535355","562340a5-304f-3531-3330-304a57535356"],"type_of_change":"2","version":"HPD8"}],"id":{"product":"b5c5978ca68a42089c65763237c54346","version":"716d77bbe8b04280b310ef5e686623fc"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK000960JWSSQ, VK001920JWSSR, VK003840JWSST, VK007680JWSSU and VO015300JWSSV Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -VK000960JWSSQ、 VK001920JWSSR、VK003840JWSST、VK007680JWSSUおよびVO015300JWSSVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VO015300JWSSV","target_guid":"562340a5-304f-3531-3330-304a57535356","type":"sas"},{"id":"VK007680JWSSU","target_guid":"562340a5-304b-3730-3638-304a57535355","type":"sas"},{"id":"VK003840JWSST","target_guid":"562340a5-304b-3330-3834-304a57535354","type":"sas"},{"id":"VK001920JWSSR","target_guid":"562340a5-304b-3130-3932-304a57535352","type":"sas"},{"id":"VK000960JWSSQ","target_guid":"562340a5-304b-3030-3936-304a57535351","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-17T07:15:38","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK001920JWSSR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO015300JWSSV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VK000960JWSSQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VK003840JWSST","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VK007680JWSSU","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for supported HPE Mellanox adapter cards."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"19084","datemodified":"2021-07-20T15:50:46","file_list":["./etc/depmod.d/kernel-mft-mlnx-mst_pci.conf","./etc/depmod.d/kernel-mft-mlnx-mst_pciconf.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/kernel-mft-mlnx","./lib/modules/3.10.0-1127.el7.x86_64/extra/kernel-mft-mlnx/mst_pci.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/kernel-mft-mlnx/mst_pciconf.ko","./usr/share/smartupdate/kmod-kernel-mft-mlnx/component.xml"],"md5sum":"0a29f7daab0816c639767ab0b8cf23e3","name":"kmod-kernel-mft-mlnx-4.17.0-1.rhel7u8.x86_64.rpm","release":"2021-07-20T15:42:08","revision":"0","sha1sum":"334939eb6ff169ed4b493b6308ffc4b24a6238c8","size":"18KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecca403118","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"type_of_change":"1","version":"4.17"},{"bytes":"10006568","datemodified":"2021-07-20T15:49:24","file_list":["./etc/bash_completion.d/mft/mft_base_autocomplete","./etc/bash_completion.d/mft/mft_help_to_completion.py","./etc/init.d/mst","./etc/mft/RPMS/mft","./etc/mft/mft.conf","./etc/mft/mst.conf","./usr/bin/flint","./usr/bin/flint_ext","./usr/bin/mcra","./usr/bin/mdevices_info","./usr/bin/mft_uninstall.sh","./usr/bin/minit","./usr/bin/mlxfwreset","./usr/bin/mlxfwstress","./usr/bin/mlxfwstress_ext","./usr/bin/mlxgearbox","./usr/bin/mlxpci","./usr/bin/mlxprivhost","./usr/bin/mst","./usr/bin/mst_cable","./usr/bin/mst_ib_add","./usr/bin/mstop","./usr/bin/resourcedump","./usr/bin/resourceparse","./usr/bin/stedump","./usr/share/man/man1","./usr/share/man/man1/flint.1.gz","./usr/share/man/man1/mcra.1.gz","./usr/share/man/man1/mdevices_info.1.gz","./usr/share/man/man1/minit.1.gz","./usr/share/man/man1/mlxfwreset.1.gz","./usr/share/man/man1/mst.1.gz","./usr/share/man/man1/mstop.1.gz","./usr/share/mft/fw_stress_db","./usr/share/mft/fw_stress_db/stress_types.db","./usr/share/mft/prm_dbs","./usr/share/mft/prm_dbs/hca","./usr/share/mft/prm_dbs/hca/ext","./usr/share/mft/prm_dbs/hca/ext/register_access_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.dat","./usr/share/mft/prm_dbs/switch","./usr/share/mft/prm_dbs/switch/ext","./usr/share/mft/prm_dbs/switch/ext/register_access_table.adb","./usr/share/mft/prm_dbs/switch/ext/register_access_table.dat","./usr/share/smartupdate/mft/component.xml","./etc/bash_completion.d/mft/mft_help_to_completion.pyc","./etc/bash_completion.d/mft/mft_help_to_completion.pyo"],"md5sum":"630f80ed6708f596385cfbfa6377edb3","name":"mft-4.17.0-106.rhel7u8.x86_64.rpm","release":"2021-07-20T15:42:08","revision":"0","sha1sum":"2713c27d89e2370bfa6118a882b2d135ea7639fb","size":"9MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecca403118","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"type_of_change":"1","version":"4.17"}],"id":{"product":"d626ca1e86a84798ad6a218e046f62c6","version":"e8267f7449d347b8b16232dbde84bdc4"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using kernel version 3.10.0-1127.el7&nbsp;or any future errata:<br />\n<br />\n<strong># rpm -Uvh kmod-kernel-mft-mlnx-4.17.0-1.rhel7u8.x86_64.rpm mft-4.17.0-64.rhel7u8.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for Red Hat Enterprise Linux 7 Update 8 (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"101f","subdev":"0012","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30012","type":"pci","ven":"15b3"},{"dev":"101f","subdev":"0007","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30007","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T18:00:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","latest_fixes_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n"},{"curr_enhancements_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","curr_fixes_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"kmod-kernel-mft-mlnx","sw_key_expectedpath":"software:rpm"},{"name":"mft","sw_key_expectedpath":"software:rpm"},{"name":"kmod-kernel-mft-mlnx","sw_key_expectedpath":"software:rpm"},{"name":"mft","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains be2net drivers for the HPE Emulex 10/20GbE Server Adapters running under SUSE Linux Enterprise Server 12 x86_64."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12 x86_64で動作するHPE Emulex 10/20GbE サーバーアダプター用のbe2net ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"107723","datemodified":"2021-01-14T07:51:58","file_list":["./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/be2net","./lib/modules/4.12.14-94.41-default/updates/be2net/be2net.ko","./usr/share/smartupdate/be2net-kmp-default/component.xml"],"md5sum":"0da27091401168305cd9b64632d224b2","name":"be2net-kmp-default-12.0.1342.0_k4.12.14_94.41-1.sles12sp4.x86_64.rpm","release":"2021-01-14T07:43:08","revision":"0","sha1sum":"e586b0a32baad96de832d1d4cd60764a48bfac68","size":"105KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecef4cee29"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"107567","datemodified":"2021-01-14T07:49:25","file_list":["./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/be2net","./lib/modules/4.12.14-120-default/updates/be2net/be2net.ko","./usr/share/smartupdate/be2net-kmp-default/component.xml"],"md5sum":"27462c794d5e4f8915ccae7af6fcf256","name":"be2net-kmp-default-12.0.1342.0_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-01-14T07:43:08","revision":"0","sha1sum":"22b22383cfca5ef17ec987ac8a57ef81fa662a22","size":"105KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecef4cee29"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"09591d5b70d148ae85b720d091645e6c","version":"e1817901830848a0aea1e2e157a47a7a"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Emulex 10/20GbE Drivers for SUSE Linux Enterprise Server 12 x86_64"},{"lang":"ja","x_late":"HPE Emulex 10/20GbEドライバー for SUSE Linux Enterprise Server 12 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0728","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c220a","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c21d4","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072815908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 12 Service Pack 5</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"be2net-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2net-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2net-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2net-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"8635453","datemodified":"2021-05-17T23:06:40","file_list":["/CP047852.vmexe","/CP047852.vmfile","/CP047852.xml","/README.txt"],"md5sum":"c38980acfb373a51040a27089e581f7a","name":"CP047852.zip","release":"2021-05-18T04:03:16","revision":"0","sha1sum":"b2313441991bbc6962ed2f67c675fb5900e73ff0","size":"8MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021","vib_list":[]}],"id":{"product":"207e342b08574d3c81d084ed48dc2f05","version":"731bbd45621f467ba7f8b115d68ca1cb"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component requires that the CRU driver be loaded before the component can run.<br />\nThe minimum CRU version for 5.1 is 5.0.3.9.<br />\nThe minimum CRU version for 5.5 is 5.5.4.1.<br />\nThe minimum CRU version for 6.0 is 6.0.8.<br />\nThe minimum CRU version for 6.5 is 6.5.8.<br />\nThe minimum CRU version for 6.7 is 6.7.10.<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>SPP Offline mode boots a special Linux OS environment, thus the Linux Components are used, not the VMware Components</li>\n</ul>\n\n<p><br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Download the appropriate SPP</li>\n\t<li>Add the component to the SPP</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run SUM</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps to complete the firmware update</li>\n\t<li>Refer to the SPP documentation for detailed instructions at:&nbsp; <a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Component ( CPxxxxxx.zip) in a temporary directory</li>\n\t<li>From the same directory, unzip the Component:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>To perform the standalone installation, execute the command:<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>Follow the directions given by the Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system for the firmware update to take effect</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、実行する前にCRUドライバーがロードされている必要があります。<br />\n5.1の最小CRUバージョンは5.0.3.9です。<br />\n5.5の最小CRUバージョンは5.5.4.1です。<br />\n6.0の最小CRUバージョンは6.0.8です。<br />\n6.5の最小CRUバージョンは6.5.8です。<br />\n6.7の最小CRUバージョンは6.7.10です。<br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMwareコンポーネントではなく、Linuxコンポーネントが用いられます</li>\n</ul>\n\n<p><br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします</li>\n\t<li>SPPにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします</li>\n\t<li>SUMを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います</li>\n\t<li>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>コンポーネント (CPxxxxxx.zip)を一時ディレクトリに置きます</li>\n\t<li>同じディレクトリからコンポーネントをunzipします:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>スタンドアロンのインストールを行うために、次のコマンドを実行します：<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>コンポーネントの指示に従います</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n\t<li>システムを再起動し、ファームウェアのアップデートを有効にします</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware - HPE Apollo 4200 Gen9/HPE ProLiant XL420 Gen9 (U19) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for VMware - HPE Apollo 4200 Gen9/HPE ProLiant XL420 Gen9 (U19)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"5","minor":"5","name":"VMware vSphere 5.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"5","minor":"1","name":"VMware vSphere 5.1","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-05T03:52:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>Ver. 2.80_10-16-2020(B) contains updates to the component packaging and is functionally equivalent to ver. 2.80_10-16-2020. It is not necessary to upgrade with Revision (B) if a previous component revision was used to upgrade the firmware to 2.80_10-16-2020.</p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U19","value":"HPE ProLiant XL420 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"}],"sw_keys":[{"name":"U19","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"本產品包含 Red Hat Enterprise Linux 7 x86_64 下執行的 HPE Intel i40e 乙太網路 NIC 之 SRIOV 虛擬功能驅動程式。"},{"lang":"en","x_late":"This product contains the SRIOV virtual function drivers for the HPE Intel i40e Ethernet NICs running under Red Hat Enterprise Linux 7 x86_64."},{"lang":"ko","x_late":"이 제품에는 Red Hat Enterprise Linux 7 x86_64에서 실행되는 HPE Intel i40e 이더넷 NIC용 SRIOV 가상 기능 드라이버가 포함되어 있습니다."},{"lang":"cn","x_late":"本产品包含适用于在Red Hat Enterprise Linux 7 x86_64下运行的HPE Intel i40e以太网网卡的SRIOV虚拟功能驱动程序。"},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7 x86_64で動作するHPE Intel i40e Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"93612","datemodified":"2021-08-24T16:04:46","file_list":["./etc/depmod.d/hp-iavf.conf","./etc/dracut.conf.d/hp-iavf-oob.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/hp-iavf","./lib/modules/3.10.0-1160.el7.x86_64/extra/hp-iavf/iavf.ko","./usr/lib/.build-id","./usr/lib/.build-id/e9","./usr/lib/.build-id/e9/f9d6f321c1f914d626f033175748e6749dcddf","./usr/share/smartupdate/kmod-hp-iavf/component.xml"],"md5sum":"9a3738c394b2dbcf7c79a0f3421d655c","name":"kmod-hp-iavf-4.2.7-1.rhel7u9.x86_64.rpm","release":"2021-08-24T15:53:07","revision":"0","sha1sum":"5c4379846e41e137b091697fbd6c7b0111bbf080","size":"91KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec0e19bfd1"],"type_of_change":"0","version":"4.2.7-1"},{"bytes":"93613","datemodified":"2021-08-24T16:03:35","file_list":["./etc/depmod.d/hp-iavf.conf","./etc/dracut.conf.d/hp-iavf-oob.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/hp-iavf","./lib/modules/3.10.0-1127.el7.x86_64/extra/hp-iavf/iavf.ko","./usr/lib/.build-id","./usr/lib/.build-id/01","./usr/lib/.build-id/01/257c89ae6a7b38a70c5af45a31cc1bbf0792ad","./usr/share/smartupdate/kmod-hp-iavf/component.xml"],"md5sum":"a6c17788e21c7c0a47a5c54849bbf848","name":"kmod-hp-iavf-4.2.7-1.rhel7u8.x86_64.rpm","release":"2021-08-24T15:53:07","revision":"0","sha1sum":"a3c528f42200cbf1a300c25f603a7ba3bb0a54e5","size":"91KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec0e19bfd1"],"type_of_change":"0","version":"4.2.7-1"}],"id":{"product":"58d1a656061f4ce896db266c33677e70","version":"0630783d3c9e46cc8079f656dc99496a"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"},{"lang":"ja","x_late":"<p>インストールのノートについてREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Intel iavf Drivers for Red Hat Enterprise Linux 7 x86_64"},{"lang":"ja","x_late":"HPE Intel iavfドライバー for Red Hat Enterprise Linux 7 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"1592","subdev":"0002","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159280860002","type":"pci","ven":"8086"},{"dev":"1592","subdev":"0006","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159280860006","type":"pci","ven":"8086"},{"dev":"159B","subdev":"0003","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159b80860003","type":"pci","ven":"8086"},{"dev":"159B","subdev":"0005","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159b80860005","type":"pci","ven":"8086"},{"dev":"1593","subdev":"0005","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159380860005","type":"pci","ven":"8086"},{"dev":"1592","subdev":"000E","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-15928086000e","type":"pci","ven":"8086"},{"dev":"1593","subdev":"000C","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-15938086000c","type":"pci","ven":"8086"},{"dev":"1581","subdev":"00F8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1581159000f8","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>This product now supports Red Hat Enterprise Linux 7 update 9</li>\n\t<li>This product now supports the following servers:</li>\n</ul>\n\n<p style=\"margin-left:80px\">&nbsp;HPE Superdome Flex 280 &nbsp;<br />\n&nbsp;HPE Superdome Flex Server &nbsp;<br />\n&nbsp;HPE Superdome Flex 2&nbsp;</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where HyperV Ping is lost after change MTU on VF interface in a VM linux</li>\n\t<li>This product addresses an issue which could lead to traffic interrupts and full traffic stop through the bond when VFs were added to bonding-alb/tlb modes<br />\n\t&nbsp;</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-hp-iavf","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-iavf","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-iavf","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-iavf","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"tw","x_late":"HPE SNMP 代理程式 (hp-snmp-agents) 彙集了多個以 SNMP 通訊協定為基礎的代理程式及工具，可讓您透過 SNMP 來監控風扇、電源供應器、溫度感應器以及其他管理事件。另外，提供下列項目： 基礎及伺服器代理程式、儲存子系統代理程式、網路子系統代理程式、SNMP 動態載入模組及網路支援應用程式。"},{"lang":"en","x_late":"The HPE SNMP Agents (hp-snmp-agents) is a collection  of SNMP  protocol based agents  and tools which enables monitoring of fans, power supplies, temperature sensors and other management events via SNMP. It also provides the following: Foundation and Server agents, Storage Subsystem agents, Network Subsystem agents, the SNMP Dynamically Loaded Module, and the web support applications."},{"lang":"ko","x_late":"HPE SNMP 에이전트(hp-snmp-agents)는 SNMP를 통해 팬, 전원 공급 장치, 온도 센서 및 기타 관리 이벤트를 모니터링하게 하는 SNMP 프로토콜 기반 에이전트 및 도구 모음입니다. 이 외에도 파운데이션 및 서버 에이전트, 스토리지 하위 시스템 에이전트, 네트워크 하위 시스템 에이전트, SNMP 동적 로드 모듈 및 웹 지원 응용 프로그램 등을 제공합니다."},{"lang":"cn","x_late":"HPE SNMP Agents (hp-snmp-agents) 是一系列基于 SNMP 协议的代理程序和工具，能够通过 SNMP 监控风扇、电源、温度传感器和其他管理事件。它还提供了以下程序： 基础架构和服务器代理程序、存储子系统代理程序、网络子系统代理程序、SNMP 动态加载模块和 Web 支持应用程序。"},{"lang":"ja","x_late":"HPE SNMPエージェント（hp-snmp-agents）は、SNMPプロトコル ベースのエージェント、およびファンの監視、電源、温度センサー、およびその他管理イベントをSNMP経由で行うツールを集めたものです。 また、次の機能も提供します。 基本およびサーバーエージェント、ストレージ サブシステムエージェント、ネットワークサブシステムエージェント、SNMP Dynamically Loaded Module、およびWebサポート アプリケーション。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[],"files":[{"bytes":"1290421","datemodified":"2021-08-25T03:49:31","file_list":["./etc/hp-snmp-agents.conf","./etc/logrotate.d/hp-snmp-agents","./opt/hp/hp-snmp-agents","./opt/hp/hp-snmp-agents/addons","./opt/hp/hp-snmp-agents/cma.conf","./opt/hp/hp-snmp-agents/hp-snmp-agents.license","./opt/hp/hp-snmp-agents/hp-snmp-agents.manifest","./opt/hp/hp-snmp-agents/hp-snmp-agents.rebuild.spec","./opt/hp/hp-snmp-agents/hprpm.xpm","./opt/hp/hp-snmp-agents/mibs","./opt/hp/hp-snmp-agents/mibs/cmafdtnobjects.conf","./opt/hp/hp-snmp-agents/mibs/cmanicobjects.conf","./opt/hp/hp-snmp-agents/mibs/cmaobjects.conf","./opt/hp/hp-snmp-agents/mibs/cmaobjects.mibdef","./opt/hp/hp-snmp-agents/mibs/cmaobjects.mibver","./opt/hp/hp-snmp-agents/mibs/cmaobjects.regmib","./opt/hp/hp-snmp-agents/mibs/cmastorobjects.conf","./opt/hp/hp-snmp-agents/mibs/cmasvrobjects.conf","./opt/hp/hp-snmp-agents/nic","./opt/hp/hp-snmp-agents/nic/bin","./opt/hp/hp-snmp-agents/nic/bin/cmanicd","./opt/hp/hp-snmp-agents/nic/bin/hpetfe","./opt/hp/hp-snmp-agents/nic/etc","./opt/hp/hp-snmp-agents/nic/etc/HPcmanic.pp","./opt/hp/hp-snmp-agents/nic/etc/cmanic","./opt/hp/hp-snmp-agents/nic/etc/cmanicd","./opt/hp/hp-snmp-agents/rebuild","./opt/hp/hp-snmp-agents/server","./opt/hp/hp-snmp-agents/server/bin","./opt/hp/hp-snmp-agents/server/bin/cmahealthd","./opt/hp/hp-snmp-agents/server/bin/cmahostd","./opt/hp/hp-snmp-agents/server/bin/cmapeerd","./opt/hp/hp-snmp-agents/server/bin/cmaperfd","./opt/hp/hp-snmp-agents/server/bin/cmasm2d","./opt/hp/hp-snmp-agents/server/bin/cmastdeqd","./opt/hp/hp-snmp-agents/server/bin/cmathreshd","./opt/hp/hp-snmp-agents/server/bin/distro-id.sh","./opt/hp/hp-snmp-agents/server/etc","./opt/hp/hp-snmp-agents/server/etc/cmad","./opt/hp/hp-snmp-agents/server/etc/cmahealthd","./opt/hp/hp-snmp-agents/server/etc/cmahostd","./opt/hp/hp-snmp-agents/server/etc/cmapeerd","./opt/hp/hp-snmp-agents/server/etc/cmaperfd","./opt/hp/hp-snmp-agents/server/etc/cmarackd","./opt/hp/hp-snmp-agents/server/etc/cmasm2d","./opt/hp/hp-snmp-agents/server/etc/cmastdeqd","./opt/hp/hp-snmp-agents/server/etc/cmathreshd","./opt/hp/hp-snmp-agents/server/etc/cpqbssa.txt","./opt/hp/hp-snmp-agents/server/etc/cpqriisd","./opt/hp/hp-snmp-agents/share","./opt/hp/hp-snmp-agents/share/doc","./opt/hp/hp-snmp-agents/share/doc/HP_SNMP_Trap_Guide.txt","./opt/hp/hp-snmp-agents/storage","./opt/hp/hp-snmp-agents/storage/bin","./opt/hp/hp-snmp-agents/storage/bin/cmaeventd","./opt/hp/hp-snmp-agents/storage/bin/cmafcad","./opt/hp/hp-snmp-agents/storage/bin/cmaidad","./opt/hp/hp-snmp-agents/storage/bin/cmaided","./opt/hp/hp-snmp-agents/storage/bin/cmasasd","./opt/hp/hp-snmp-agents/storage/bin/cmascsid","./opt/hp/hp-snmp-agents/storage/bin/libcpqimgr-x86_64.so","./opt/hp/hp-snmp-agents/storage/etc","./opt/hp/hp-snmp-agents/storage/etc/cmaeventd","./opt/hp/hp-snmp-agents/storage/etc/cmafcad","./opt/hp/hp-snmp-agents/storage/etc/cmaidad","./opt/hp/hp-snmp-agents/storage/etc/cmaided","./opt/hp/hp-snmp-agents/storage/etc/cmasasd","./opt/hp/hp-snmp-agents/storage/etc/cmascsid","./opt/hp/hp-snmp-agents/storage/etc/cmastorobjects.conf","./opt/hp/hp-snmp-agents/utils","./opt/hp/hp-snmp-agents/utils/usb-device.sh","./opt/hp/hp-snmp-agents/webagent","./opt/hp/hp-snmp-agents/webagent/csginkgo","./sbin/hpsnmpconfig","./usr/lib/systemd/scripts/hp-snmp-agents.sh","./usr/lib/systemd/system/hp-snmp-agents.service","./usr/lib64/libcmaX64.so","./usr/lib64/libcmaX64.so.1","./usr/lib64/libcmaX64.so.1.0","./usr/lib64/libcmacommon64.so","./usr/lib64/libcmacommon64.so.1","./usr/lib64/libcmacommon64.so.1.0","./usr/lib64/libcmaconf64.so","./usr/lib64/libcmaconf64.so.1","./usr/lib64/libcmaconf64.so.1.0","./usr/lib64/libcmapeer64.so","./usr/lib64/libcmapeer64.so.1","./usr/lib64/libcmapeer64.so.1.0","./usr/share/man/man4/hp-snmp-agents.4.gz","./usr/share/man/man8/cmanicd.8.gz","./usr/share/smartupdate/hp-snmp-agents/component.xml","./var/log/hp-snmp-agents","./var/spool/compaq"],"md5sum":"e2679bc168b091daaf1f7eb636911ac8","name":"hp-snmp-agents-10.94-689.8.sles12.x86_64.rpm","release":"2021-08-25T03:40:08","revision":"0","sha1sum":"5c3f2cbab59a1fdb6004234040f712eae2fa2d5a","size":"1MB","target_guids":[],"type_of_change":"0","version":"10.9.4"}],"id":{"product":"3e563464a2c34e22b29e876df5230ef9","version":"f9399420cfd84c6b90abfe9dde8513c6"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<P>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</P>\n<P>To install the package, type: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<B><I>rpm -ivh hp-snmp-agents-&lt;version&gt;.rpm</I></B></P>\n<P>To check whether the package is loaded properly type: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<B><I>/etc/init.d/hp-snmp-agents status</I></B></P>\n<P>Additional help is available by typing: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<B><I>man hp-snmp-agents</I></B></P>"},{"lang":"ja","x_late":"<P>システム管理者（root）としてログインし、RPMをご使用のハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</P>\n<P>パッケージをインストールするには、次のようにタイプします。</P>\n<P>         <B><I>rpm -ivh hp-snmp-agents-<version>.rpm</I></B></P>\n<P>パッケージが正しくロードされているか、以下をタイプして確認します。</P>\n<P>         <B><I>/etc/init.d/hp-snmp-agents status</I></B></P>\n<P>以下のコマンドを実行してヘルプを参照してください。</P>\n<P>         <B><I>man hp-snmp-agents</I></B></P>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"HPE SNMP 代理程式（適用於 SUSE Linux Enterprise Server 12）"},{"lang":"en","x_late":"HPE SNMP Agents for SUSE LINUX Enterprise Server 12"},{"lang":"ko","x_late":"SUSE Linux Enterprise Server 12용 HPE SNMP Agent"},{"lang":"cn","x_late":"用于 SUSE LINUX Enterprise Server 12 的 HPE SNMP Agents"},{"lang":"ja","x_late":"HPE SNMPエージェント for SUSE Linux Enterprise Server 12"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"3309","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3307","subdev":"3309","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-28T13:05:41","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>Addressed issue where the HPE Synergy 3820C 10/20Gb Converged Network Adapter was showing not supported</li>\n\t<li>Corrected invalid utf8mb4 char in database</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>TBD</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"J06","value":"HP ProLiant MicroServer Gen8"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"P66","value":"HP ProLiant DL980 G7 Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A16","value":"HP ProLiant DL585 G7 Server"},{"key":"I25","value":"HP ProLiant BL680c G7 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 v2 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"A19","value":"HP ProLiant BL465c G7 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"P78","value":"HP ProLiant ML310e Gen8 v2 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"I27","value":"HP ProLiant BL460c G7 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"A24","value":"HP ProLiant SL335s G7 Server"},{"key":"P68","value":"HP ProLiant DL360 G7 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"O41","value":"HP ProLiant MicroServer"},{"key":"A20","value":"HP ProLiant BL685c G7 Server"},{"key":"P67","value":"HP ProLiant DL380 G7 Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"P65","value":"HP ProLiant DL580 G7 Server"}],"sw_keys":[{"name":"hp-snmp-agents","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH0300JDYTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFLRCD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3330-304a44595448","Version":"HPD6"},{"DeviceName":"EH0450JDYTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFLRCD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3435-304a4459544b","Version":"HPD6"},{"DeviceName":"EH0600JDYTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFLRCD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3630-304a4459544c","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EH0300JDYTH, EH0450JDYTK, and EH0600JDYTL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EH0300JDYTH, EH0450JDYTK&nbsp;and EH0600JDYTL Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong>&nbsp;&nbsp;<br />\n&nbsp; &nbsp; &nbsp; None<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5558757","datemodified":"2021-07-23T08:16:29","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b9340d29be-HPD6-9.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-b9340d29be-HPD6-9.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b9340d29be-HPD6-9.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b9340d29be-HPD6-9.1/CP048088.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b9340d29be-HPD6-9.1/HKFLRCD6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-b9340d29be-HPD6-9.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b9340d29be-HPD6-9.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b9340d29be-HPD6-9.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b9340d29be-HPD6-9.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048088.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048088.scexe"],"md5sum":"f18a03dfabf206bf1eb0a4986e217710","name":"firmware-hdd-b9340d29be-HPD6-9.1.x86_64.rpm","release":"2021-07-23T08:04:09","revision":"0","sha1sum":"498f3770b82688fd8833fac7b3d0b920b9d02502","size":"5MB","target_guids":["002340a5-4500-3048-3330-304a44595448","002340a5-4500-3048-3435-304a4459544b","002340a5-4500-3048-3630-304a4459544c"],"type_of_change":"1","version":"HPD6"}],"id":{"product":"ada4d6aedd4b4604b810f81be7da5b19","version":"3d2160ca84eb445b92f71a993abc1068"},"installation":{"command":"CP040317.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EH0300JDYTH, EH0450JDYTK and EH0600JDYTL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux(x64) - EH0300JDYTH、EH0450JDYTKおよびEH0600JDYTLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"EH0300JDYTH","target_guid":"002340a5-4500-3048-3330-304a44595448","type":"sas"},{"id":"EH0450JDYTK","target_guid":"002340a5-4500-3048-3435-304a4459544b","type":"sas"},{"id":"EH0600JDYTL","target_guid":"002340a5-4500-3048-3630-304a4459544c","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T11:31:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH0600JDYTL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0300JDYTH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0450JDYTK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900374","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the boot BIOS and firmware of QLogic Fibre Channel host bus adapters."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"11724443","datemodified":"2021-08-25T12:48:57","file_list":["/CP048725_BUILD_2.data","/CP048725.vmexe","/CP048725.vmexe64","/CP048725.vmfile","/CP048725_VMw.zip","/CP048725.xml","/payload.json","/CP048725_VMw.zip/index.xml","/CP048725_VMw.zip/vendor-index.xml","/CP048725_VMw.zip/metadata.zip","/CP048725_VMw.zip/vib20/CP048725/HPE_bootbank_CP048725_2021.10.01.2-6.7.0.7535516.vib","/CP048725_VMw.zip/metadata.zip/vendor-index.xml","/CP048725_VMw.zip/metadata.zip/vmware.xml","/CP048725_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048725_2021.10.01.2-6.7.0.7535516.xml","/CP048725_VMw.zip/metadata.zip/vibs/CP048725-4413686065022080414.xml"],"md5sum":"53d0a3a2350011c27b5bfb3f379d9d91","name":"CP048725.zip","release":"2021-08-25T12:43:04","revision":"0","sha1sum":"8dbf7b38f5fab9bd009135e26ea1578487ef0e25","size":"11MB","target_guids":[],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"CP048725","version":"2021.10.01.2-6.7.0.7535516"}]}],"id":{"product":"57b24efb580f4389a16a8a829564fc5f","version":"ef5c6bc46cf042f9b29ef81f906911c9"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated if the ESXi host is Gen9 Server or Enter the IP or DNS address of the iLO of the ESXi host if the Sever is Gen10 and above</li>\n\t<li>Enter the ESXi host/iLO credentials (root or administrator username and password) based on Gen9/Gen10 and above</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for QLogic Fibre Channel Host Bus Adapters for VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-18T06:47:37","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\" dir=\"LTR\" style=\"width:935px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Speed</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">MBI</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Firmware</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">UEFI</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Boot Bios</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE 81Q 8Gb PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.82.00</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8.08.207</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.00</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.56</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE 82Q 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.82.00</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8.08.207</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.00</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.56</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE 84Q 8Gb Quad Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.82.00</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8.08.207</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.00</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.56</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1000Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">6.04.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8.08.232</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.43</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1000Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">6.04.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8.08.232</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.43</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">1.75.07</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">9.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.64</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">1.75.07</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">9.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.64</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">1.75.07</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">9.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.64</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">1.75.07</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">9.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.64</p>\n\t\t\t</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"QLOGIC","sw_key_expectedpath":"firmware:QLOGIC"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JWXKH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG08scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a57584b48","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB016000JWXKH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB016000JWXKH Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3740792","datemodified":"2021-07-26T16:00:18","file_list":["cp049126.xml","cpqsetup.exe","payload.json","setup.dll","TAMG08scHPD9.REL"],"md5sum":"43dbb9db897d42ef1a51552f8dadbf88","name":"cp049126.exe","release":"2021-07-26T15:49:04","revision":"0","sha1sum":"95b50413eb655d5b4ebf684c9326d93652fbdff0","size":"3MB","target_guids":["4d2340a5-3042-3631-3030-304a57584b48"],"type_of_change":"1","version":"HPD9"}],"id":{"product":"3b6a8a58b8154bb1b3a7b5b4416448b8","version":"eb14b7963f6b4a4fa0005a555b8a559e"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB016000JWXKH Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB016000JWXKH","target_guid":"4d2340a5-3042-3631-3030-304a57584b48","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T15:44:38","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB016000JWXKH","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component contains version 12.0.1192.0 of the Emulex Storport driver for Extended Systems which provides Fibre Channel over Ethernet-Host Bus Adapter driver support for HPE Storage RAID Arrays."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"2039096","datemodified":"2021-08-27T06:39:40","file_list":["brcmdrvr-fcoe-12.0.1192.0-21.exe","cp048541.xml","cpqsetup.exe","ElxCNAInstaller.dll","install.xml","SysConfig.frm","SysConfig.frm.ja"],"md5sum":"3a7d8d82c5c28da64319aaef23104adc","name":"cp048541.exe","release":"2021-08-27T06:37:04","revision":"0","sha1sum":"4af2cf5440d940d16b1d18a79d41b3ad75bc3530","size":"1MB","target_guids":[],"type_of_change":"1","version":"12.0.1192.0"}],"id":{"product":"083d2e65d49a443b865c3df5b56fca1c","version":"21e0a26205b4497ea1f13ec926072c9e"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>&nbsp;</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation.</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Fibre Channel Over Ethernet Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T11:01:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p style=\"margin-left:0in; margin-right:0in\">Updated to driver version 12.0.1192.0</p>\n\n<p>&nbsp;</p>\n\n<p>Removed the raw driver file folder.&nbsp; The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:<br />\n<br />\n&nbsp;&nbsp;&nbsp; brcmdrvr-fcoe-version.exe /q2 extract=2<br />\n<br />\nThe extracted files are located:<br />\n<br />\n&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Broadcom\\Drivers\\FCoE-version<br />\n<br />\nEach kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,<br />\n<br />\n&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Broadcom\\Drivers\\FCoE-version\\x64\\win2012</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"}],"sw_keys":[{"name":"elxcna.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"},{"name":"elxcna.sys","sw_key_expectedpath":"%programfiles%\\Broadcom\\AutoPilot Installer\\FCoE\\Drivers\\Storport\\x64\\Win2019"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware for mezzanine Converged Network adapters."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"12977197","datemodified":"2021-08-25T11:23:25","file_list":["/CP048524_BUILD_7.data","/CP048524.vmexe","/CP048524.vmexe64","/CP048524.vmfile","/CP048524_VMw.zip","/CP048524.xml","/payload.json","/CP048524_VMw.zip/index.xml","/CP048524_VMw.zip/vendor-index.xml","/CP048524_VMw.zip/metadata.zip","/CP048524_VMw.zip/vib20/CP048524/HPE_bootbank_CP048524_2021.10.01.7-6.5.0.4240417.vib","/CP048524_VMw.zip/metadata.zip/vendor-index.xml","/CP048524_VMw.zip/metadata.zip/vmware.xml","/CP048524_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048524_2021.10.01.7-6.5.0.4240417.xml","/CP048524_VMw.zip/metadata.zip/vibs/CP048524--9111127050870052922.xml"],"md5sum":"957c5d9944026840718a9d24a87d974e","name":"CP048524.zip","release":"2021-08-25T11:16:27","revision":"0","sha1sum":"b6386807dabdb537d23b1803cb37fbacb50a7c39","size":"12MB","target_guids":[],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"CP048524","version":"2021.10.01.7-6.5.0.4240417"}]}],"id":{"product":"570c7c3819fe4493a10b92c6ac313f50","version":"3878375270c84ca8a2959137c40661ed"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the&nbsp;Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, <strong>if the component is supported by SUM but is not yet part of an SPP:</strong></strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Firmware Flash for Emulex Mezzanine Converged Network Adapters for VMware vSphere  6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"20000"},"supported_devices":[{"dev":"0724","subdev":"1935","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1935","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1934","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"1934","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T10:38:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p dir=\"LTR\">Updated CNA (XE100 series) firmware</p>\n\n<p>This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 20Gb 2-port 650FLB Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1345.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 20Gb 2-port 650M Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1345.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"emulex_cna","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXn0HPD7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57485050","Version":"HPD7"},{"DeviceName":"EH000600JWHPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXn0HPD7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5748504e","Version":"HPD7"},{"DeviceName":"EH000300JWHPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXn0HPD7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5748504c","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EH000900JWHPP, EH000600JWHPN and EH000300JWHPL"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EH000900JWHPP、EH000600JWHPN および EH000300JWHPL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"16176671","datemodified":"2021-08-27T18:52:01","file_list":["/CP049136_BUILD_1.data","/CP049136.vmexe","/CP049136.vmexe64","/CP049136.vmfile","/CP049136_VMw.zip","/CP049136.xml","/payload.json","/CP049136_VMw.zip/index.xml","/CP049136_VMw.zip/vendor-index.xml","/CP049136_VMw.zip/metadata.zip","/CP049136_VMw.zip/vib20/CP049136/HPE_bootbank_CP049136_HPD7.1-7.0.0.15843807.vib","/CP049136_VMw.zip/metadata.zip/vendor-index.xml","/CP049136_VMw.zip/metadata.zip/vmware.xml","/CP049136_VMw.zip/metadata.zip/vibs/CP049136--1021048504555796351.xml","/CP049136_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049136_HPD7.1-7.0.0.15843807.xml"],"md5sum":"cd7a1bc51a52ee610136dcaa39939d7c","name":"CP049136.zip","release":"2021-08-27T18:47:24","revision":"0","sha1sum":"e1bb406e0aa6b8298b2e57999d17c4331162e55b","size":"15MB","target_guids":["452340a5-3048-3030-3930-304a57485050","452340a5-3048-3030-3630-304a5748504e","452340a5-3048-3030-3330-304a5748504c"],"type_of_change":"1","version":"HPD7","vib_list":[{"name":"CP049136","version":"HPD7.1-7.0.0.15843807"}]}],"id":{"product":"486d4489346f4ec8a160ad4ef3c94f99","version":"5d8ec9a8c2dd4a6385901d63e1a41762"},"installation":{"command":"CP041673.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL  Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EH000900JWHPP、EH000600JWHPNおよびEH000300JWHPLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EH000900JWHPP","target_guid":"452340a5-3048-3030-3930-304a57485050","type":"sas"},{"id":"EH000600JWHPN","target_guid":"452340a5-3048-3030-3630-304a5748504e","type":"sas"},{"id":"EH000300JWHPL","target_guid":"452340a5-3048-3030-3330-304a5748504c","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T17:57:09","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This firmware fixes a condition that could cause the heads to land on the media in an emergency power off situation, and eliminates a command timeout issue. Some internal logging operations were refined at the same time.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH000900JWHPP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000300JWHPL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000600JWHPN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWKGR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574b4752","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB006000GWKGR"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB006000GWKGR Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"6136728","datemodified":"2021-07-23T07:33:50","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-5.1/CP048131.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-5.1/HVLAeAaseFG1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048131.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048131.scexe"],"md5sum":"0d9859ac95a9e5da7c2ca19a259f089d","name":"firmware-hdd-7f2a26e6d0-HPG1-5.1.x86_64.rpm","release":"2021-07-23T07:21:06","revision":"0","sha1sum":"3b899cdf08227bb5c172d44228c802a54c8e475f","size":"5MB","target_guids":["4d2340a5-3042-3630-3030-3047574b4752"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"d33174a587ab4b3ea4d5e4e22de786d1","version":"69e5c7740ff0497287195eec9bc9a7b9"},"installation":{"command":"CP041521.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB006000GWKGR Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB006000GWKGRドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB006000GWKGR","target_guid":"4d2340a5-3042-3630-3030-3047574b4752","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-26T11:09:08","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000GWKGR","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400JWDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57444b50","Version":"HPD2"},{"DeviceName":"EO000800JWDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57444b51","Version":"HPD2"},{"DeviceName":"EO001600JWDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57444b52","Version":"HPD2"},{"DeviceName":"MO000400JWDKU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57444b55","Version":"HPD2"},{"DeviceName":"MO000800JWDKV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57444b56","Version":"HPD2"},{"DeviceName":"MO001600JWDLA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57444c41","Version":"HPD2"},{"DeviceName":"MO003200JWDLB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57444c42","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EO000400JWDKP、EO000800JWDKQ、EO001600JWDKR、MO000400JWDKU、MO000800JWDKV、 MO001600JWDLA および MO003200JWDLB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD1<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5595948","datemodified":"2021-07-23T08:14:31","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD2-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD2-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD2-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD2-6.1/CP048092.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD2-6.1/HBCMSssseFD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD2-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD2-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD2-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD2-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048092.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048092.scexe"],"md5sum":"c7b0ea9c34697880536ac064cc4d7b93","name":"firmware-hdd-5dcf26fa42-HPD2-6.1.x86_64.rpm","release":"2021-07-23T08:01:16","revision":"0","sha1sum":"e5b62e18930bf54a67b06244386c34c44f17b964","size":"5MB","target_guids":["452340a5-304f-3030-3430-304a57444b50","452340a5-304f-3030-3830-304a57444b51","452340a5-304f-3130-3630-304a57444b52","4d2340a5-304f-3030-3430-304a57444b55","4d2340a5-304f-3030-3830-304a57444b56","4d2340a5-304f-3130-3630-304a57444c41","4d2340a5-304f-3330-3230-304a57444c42"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"896ea0712e9c4853949ccb47860e6c63","version":"0d79eecee8e54d71a1b79af30953b7a8"},"installation":{"command":"CP040329.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64)  - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - EO000400JWDKP、EO000800JWDKQ、EO001600JWDKR、MO000400JWDKU、MO000800JWDKV、MO001600JWDLA、およびMO003200JWDLBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EO001600JWDKR","target_guid":"452340a5-304f-3130-3630-304a57444b52","type":"sas"},{"id":"MO001600JWDLA","target_guid":"4d2340a5-304f-3130-3630-304a57444c41","type":"sas"},{"id":"MO003200JWDLB","target_guid":"4d2340a5-304f-3330-3230-304a57444c42","type":"sas"},{"id":"EO000400JWDKP","target_guid":"452340a5-304f-3030-3430-304a57444b50","type":"sas"},{"id":"MO000400JWDKU","target_guid":"4d2340a5-304f-3030-3430-304a57444b55","type":"sas"},{"id":"EO000800JWDKQ","target_guid":"452340a5-304f-3030-3830-304a57444b51","type":"sas"},{"id":"MO000800JWDKV","target_guid":"4d2340a5-304f-3030-3830-304a57444b56","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T12:04:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EO000400JWDKP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600JWDLA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000800JWDKQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000400JWDKU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200JWDLB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800JWDKV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO001600JWDKR","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWWQP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNESD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57575150","Version":"HPD6"},{"DeviceName":"MB006000JWWQN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNESD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a5757514e","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB008000JWWQP and MB006000JWWQN"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB008000JWWQPおよびMB006000JWWQN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MB008000JWWQP and MB006000JWWQN Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD2</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4065320","datemodified":"2021-07-25T20:28:34","file_list":["cp048649.xml","cpqsetup.exe","payload.json","SCIMARRNESD6.rel","setup.dll"],"md5sum":"caff32c0adbac1851ac336023fb60b69","name":"cp048649.exe","release":"2021-07-25T20:21:11","revision":"0","sha1sum":"5fa2f673a3574115c543ded74789f2f125cabfb3","size":"3MB","target_guids":["4d2340a5-3042-3830-3030-304a57575150","4d2340a5-3042-3630-3030-304a5757514e"],"type_of_change":"1","version":"HPD6"}],"id":{"product":"8e4da865e5b44ea38e4b650ce9a93715","version":"cb2403eaa693447a9cf1f95d9a8d0c70"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB008000JWWQP and MB006000JWWQN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for Windows (x64) - MB008000JWWQPおよびMB006000JWWQNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB006000JWWQN","target_guid":"4d2340a5-3042-3630-3030-304a5757514e","type":"sas"},{"id":"MB008000JWWQP","target_guid":"4d2340a5-3042-3830-3030-304a57575150","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T18:34:07","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000JWWQP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB006000JWWQN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWWQH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757575148","Version":"HPG3"},{"DeviceName":"MB002000GWWQF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757575146","Version":"HPG3"},{"DeviceName":"MB001000GWWQE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757575145","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB004000GWWQH, MB002000GWWQF and MB001000GWWQE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG2</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG2<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp;</strong>&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"17503636","datemodified":"2021-08-27T11:57:32","file_list":["/CP048430_BUILD_2.data","/CP048430.vmexe","/CP048430.vmexe64","/CP048430.vmfile","/CP048430_VMw.zip","/CP048430.xml","/payload.json","/CP048430_VMw.zip/index.xml","/CP048430_VMw.zip/vendor-index.xml","/CP048430_VMw.zip/metadata.zip","/CP048430_VMw.zip/vib20/CP048430/HPE_bootbank_CP048430_HPG3.2-7.0.0.15843807.vib","/CP048430_VMw.zip/metadata.zip/vendor-index.xml","/CP048430_VMw.zip/metadata.zip/vmware.xml","/CP048430_VMw.zip/metadata.zip/vibs/CP048430-384385079037484807.xml","/CP048430_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048430_HPG3.2-7.0.0.15843807.xml"],"md5sum":"24a00a51b0ce11cd55905a26809ce9a5","name":"CP048430.zip","release":"2021-08-27T11:52:14","revision":"0","sha1sum":"2ba8e5af35a49212f7ef81c50d62daef26254d42","size":"16MB","target_guids":["4d2340a5-3042-3430-3030-304757575148","4d2340a5-3042-3230-3030-304757575146","4d2340a5-3042-3130-3030-304757575145"],"type_of_change":"1","version":"HPG3","vib_list":[{"name":"CP048430","version":"HPG3.2-7.0.0.15843807"}]}],"id":{"product":"df6ba3c2e569412ab3999b9575ddb1d8","version":"fa792b6f7b3a437ebcfc68e1bc6ed39f"},"installation":{"command":"CP043256.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>T</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p><strong>T</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - MB004000GWWQH、MB002000GWWQF、およびMB001000GWWQEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB004000GWWQH","target_guid":"4d2340a5-3042-3430-3030-304757575148","type":"sata"},{"id":"MB002000GWWQF","target_guid":"4d2340a5-3042-3230-3030-304757575146","type":"sata"},{"id":"MB001000GWWQE","target_guid":"4d2340a5-3042-3130-3030-304757575145","type":"sata"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-10T08:34:29","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB001000GWWQE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB002000GWWQF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB004000GWWQH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWKGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAnAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a574b4755","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB004000JWKGU"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB004000JWKGU"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB004000JWKGU Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD1<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"6135077","datemodified":"2021-07-23T08:13:50","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-2.1/CP048103.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-2.1/HVLAnAsseFD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048103.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048103.scexe"],"md5sum":"4147120f47ec4170154ae54885193007","name":"firmware-hdd-2c27a7a9a4-HPD2-2.1.x86_64.rpm","release":"2021-07-23T08:01:07","revision":"0","sha1sum":"8c7992103cadac6c2e751dfe45aaa05e72d34ced","size":"5MB","target_guids":["4d2340a5-3042-3430-3030-304a574b4755"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"188f54d508794fafbb14f21866a0ffb5","version":"b54141db67c94dddad083c1db63e194a"},"installation":{"command":"CP041491.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB004000JWKGU Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) -  MB004000JWKGU ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB004000JWKGU","target_guid":"4d2340a5-3042-3430-3030-304a574b4755","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T16:43:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB004000JWKGU","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6119891","datemodified":"2021-05-18T05:02:03","file_list":["./usr/lib/i386-linux-gnu/firmware-system-p99-2.90_2021_04_29-1.1","./usr/lib/i386-linux-gnu/firmware-system-p99-2.90_2021_04_29-1.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-system-p99-2.90_2021_04_29-1.1/.setup","./usr/lib/i386-linux-gnu/firmware-system-p99-2.90_2021_04_29-1.1/CP047848.xml","./usr/lib/i386-linux-gnu/firmware-system-p99-2.90_2021_04_29-1.1/P99_2.90_04_29_2021.signed.flash","./usr/lib/i386-linux-gnu/firmware-system-p99-2.90_2021_04_29-1.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-system-p99-2.90_2021_04_29-1.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP047848.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP047848.scexe"],"md5sum":"992fabc56d147e2b22ab5b37c5794f31","name":"firmware-system-p99-2.90_2021_04_29-1.1.i386.rpm","release":"2021-05-18T04:52:19","revision":"0","sha1sum":"0f4480728bd501bc5dc177898a809e65e4b9c798","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021"}],"id":{"product":"b0d92753c2304b2890afe0bb312c776b","version":"38f3e5de5da748b0a5e2bf62682bfff2"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HPE ProLiant Agentless Management Service (<strong>AMS</strong>) and HPE SNMP Agents (<strong>SNMP Agents</strong>) are both running.&nbsp; HPE does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager 8.0.0 or later, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、iLOとの通信ができない場合に失敗します。  これは、HPE ProLiant Agentless Management Service (<strong>AMS</strong>)およびHPE SNMPエージェント(<strong>SNMP Agents</strong>)の両方が実行されているときに発生します。  HPEでは、AMSおよびSNMPエージェントを同時に実行させないことを推奨します。  「iLO device not found」エラーが発生した場合、AMSまたはSNMPエージェントを停止させて、再度フラッシュコンポーネントを実行します。<br />\n<br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上のSmart Update Manager 8.0.0以降を使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant ML110 Gen9 (P99) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant ML110 Gen9(P99)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Oracle Linux 6 (AMD64/EMT64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Oracle Linux 7","platform":"Oracle Enterprise Linux","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-05T03:47:22","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"}],"sw_keys":[{"name":"P99","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO0800JEFPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304f-3830-304a45465046","Version":"HPD3"},{"DeviceName":"EO0400JEFPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304f-3430-304a45465045","Version":"HPD3"},{"DeviceName":"EO0200JEFPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304f-3230-304a45465044","Version":"HPD3"},{"DeviceName":"MO1600JEFPC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304a45465043","Version":"HPD3"},{"DeviceName":"MO0800JEFPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3830-304a45465042","Version":"HPD3"},{"DeviceName":"MO0400JEFPA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3430-304a45465041","Version":"HPD3"},{"DeviceName":"MO0200JEFNV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3230-304a45464e56","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MO0200JEFNV, MO0400JEFPA, MO0800JEFPB, MO1600JEFPC, EO0200JEFPD, EO0400JEFPE, and EO0800JEFPF"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MO0200JEFNV、MO0400JEFPA、MO0800JEFPB、MO1600JEFPC、EO0200JEFPD、EO0400JEFPE、およびEO0800JEFPF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MO0200JEFNV, MO0400JEFPA, MO0800JEFPB, MO1600JEFPC, EO0200JEFPD, EO0400JEFPE&nbsp;and EO0800JEFPF Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong>&nbsp;&nbsp;&nbsp;&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp; None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5236659","datemodified":"2021-07-23T08:44:23","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-71af849f3b-HPD3-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-71af849f3b-HPD3-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-71af849f3b-HPD3-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-71af849f3b-HPD3-8.1/CP048183.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-71af849f3b-HPD3-8.1/HSSCPCD3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-71af849f3b-HPD3-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-71af849f3b-HPD3-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-71af849f3b-HPD3-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-71af849f3b-HPD3-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048183.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048183.scexe"],"md5sum":"395248938363c0c2e6ed37eba7d806a6","name":"firmware-hdd-71af849f3b-HPD3-8.1.x86_64.rpm","release":"2021-07-23T08:31:11","revision":"0","sha1sum":"c236ab583305d0cdf377e78aca5fc162dced4d4d","size":"4MB","target_guids":["002340a5-4500-304f-3830-304a45465046","002340a5-4500-304f-3430-304a45465045","002340a5-4500-304f-3230-304a45465044","002340a5-4d00-314f-3630-304a45465043","002340a5-4d00-304f-3830-304a45465042","002340a5-4d00-304f-3430-304a45465041","002340a5-4d00-304f-3230-304a45464e56"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"5691df43dd354d538b509faabb482ba9","version":"74e69b2754494d7a918117cc6a87aa28"},"installation":{"command":"CP040260.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MO0200JEFNV, MO0400JEFPA, MO0800JEFPB, MO1600JEFPC, EO0200JEFPD, EO0400JEFPE and EO0800JEFPF Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MO0200JEFNV、MO0400JEFPA、MO0800JEFPB、MO1600JEFPC、EO0200JEFPD、EO0400JEFPE、およびEO0800JEFPFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EO0800JEFPF","target_guid":"002340a5-4500-304f-3830-304a45465046","type":"sas"},{"id":"MO1600JEFPC","target_guid":"002340a5-4d00-314f-3630-304a45465043","type":"sas"},{"id":"EO0200JEFPD","target_guid":"002340a5-4500-304f-3230-304a45465044","type":"sas"},{"id":"MO0200JEFNV","target_guid":"002340a5-4d00-304f-3230-304a45464e56","type":"sas"},{"id":"EO0400JEFPE","target_guid":"002340a5-4500-304f-3430-304a45465045","type":"sas"},{"id":"MO0400JEFPA","target_guid":"002340a5-4d00-304f-3430-304a45465041","type":"sas"},{"id":"MO0800JEFPB","target_guid":"002340a5-4d00-304f-3830-304a45465042","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T20:47:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EO0200JEFPD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO0400JEFPE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO0800JEFPF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO0200JEFNV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO1600JEFPC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO0800JEFPB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO0400JEFPA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Intel i40en Adapters running under VMware vSphere 6.5"},{"lang":"ja","x_late":"この製品は、VMware vSphere 6.5上で動作するHPE Intel i40enアダプターのためのドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;1.10.6.</p>\n"},{"lang":"ja","x_late":"<p>この製品には、ドライバーバージョン1.10.6が含まれています。</p>\n"}],"files":[{"bytes":"444555","datemodified":"2021-09-03T03:11:43","file_list":["/cp049456.xml","/VMW-ESX-6.5.0-i40en-1.10.6-15517381.zip","/VMW-ESX-6.5.0-i40en-1.10.6-15517381.zip/VMW-ESX-6.5.0-i40en-1.10.6-offline_bundle-15517381.zip","/VMW-ESX-6.5.0-i40en-1.10.6-15517381.zip/i40en-1.10.6-1OEM.650.0.0.4598673.x86_64.vib","/VMW-ESX-6.5.0-i40en-1.10.6-15517381.zip/doc/README.txt","/VMW-ESX-6.5.0-i40en-1.10.6-15517381.zip/doc/release_note_i40en_1.10.6-1OEM.650.0.0.4598673.txt","/VMW-ESX-6.5.0-i40en-1.10.6-15517381.zip/VMW-ESX-6.5.0-i40en-1.10.6-offline_bundle-15517381.zip/index.xml","/VMW-ESX-6.5.0-i40en-1.10.6-15517381.zip/VMW-ESX-6.5.0-i40en-1.10.6-offline_bundle-15517381.zip/vendor-index.xml","/VMW-ESX-6.5.0-i40en-1.10.6-15517381.zip/VMW-ESX-6.5.0-i40en-1.10.6-offline_bundle-15517381.zip/metadata.zip","/VMW-ESX-6.5.0-i40en-1.10.6-15517381.zip/VMW-ESX-6.5.0-i40en-1.10.6-offline_bundle-15517381.zip/vib20/i40en/INT_bootbank_i40en_1.10.6-1OEM.650.0.0.4598673.vib","/VMW-ESX-6.5.0-i40en-1.10.6-15517381.zip/VMW-ESX-6.5.0-i40en-1.10.6-offline_bundle-15517381.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.5.0-i40en-1.10.6-15517381.zip/VMW-ESX-6.5.0-i40en-1.10.6-offline_bundle-15517381.zip/metadata.zip/vmware.xml","/VMW-ESX-6.5.0-i40en-1.10.6-15517381.zip/VMW-ESX-6.5.0-i40en-1.10.6-offline_bundle-15517381.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-i40en-1.10.6.xml","/VMW-ESX-6.5.0-i40en-1.10.6-15517381.zip/VMW-ESX-6.5.0-i40en-1.10.6-offline_bundle-15517381.zip/metadata.zip/vibs/i40en--6236398258338039496.xml"],"md5sum":"0bc5a0df2b6eff3aeb71aae9ba7610ec","name":"cp049456.zip","release":"2021-09-03T03:07:42","revision":"0","sha1sum":"a2c090707f98943bb5efa1fd3d982c1df2af88fe","size":"434KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec17ceb7c3"],"type_of_change":"0","version":"2020.09.14","vib_list":[{"name":"i40en","version":"1.10.6-1OEM.650.0.0.4598673"}]}],"id":{"product":"68498f6599c54afbbc323dc39761e931","version":"240b613709d74e228652346eb7ea0a03"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel i40en Driver for VMware vSphere 6.5"},{"lang":"ja","x_late":"HPE Intel i40enドライバーfor VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"},{"dev":"1572","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1572808600a1","type":"pci","ven":"8086"},{"dev":"1572","subdev":"0008","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-157280860008","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-10-02T12:56:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue which PCI device information passing to intnetcli Command-Line Interface (Intel&reg; ESXCLI Plug-In Managing tool ).</p>\n"},{"curr_enhancements_x_late":"<p>This product supports HPE ProLiant DL385 Gen10 Plus Server</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"}],"sw_keys":[{"name":"i40en:1.10.6-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK0400JEABD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM2RD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3430-304a45414244","Version":"HPD4"},{"DeviceName":"VK0800JEABE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM2RD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3830-304a45414245","Version":"HPD4"},{"DeviceName":"VO1600JEABF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM2RD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314f-3630-304a45414246","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK0400JEABD, VK0800JEABE, and VO1600JEABF"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：VK0400JEABD、VK0800JEABE、およびVO1600JEABF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp; &nbsp;&nbsp; </strong>Online HDD/SSD Flash Component for Linux (x64) - VK0400JEABD, VK0800JEABE and VO1600JEABF Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD3</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>If Power On Hours exceeds 70,000hrs, PM2R will report Hardware error (04/4C/A8) after the next Power Cycle and will not accept read/write commands. This fix will update storage location reporting when the maximum number of registrations in the Work Load Log read process reaches 70,000; the last registered 70,000th storage location will be modified to be read as the next (70,001st) storage location.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111296en_us</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4723017","datemodified":"2021-08-31T10:47:08","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8a7ecf7465-HPD4-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a7ecf7465-HPD4-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a7ecf7465-HPD4-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a7ecf7465-HPD4-2.1/CP049411.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a7ecf7465-HPD4-2.1/TAPM2RD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a7ecf7465-HPD4-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a7ecf7465-HPD4-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a7ecf7465-HPD4-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a7ecf7465-HPD4-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049411.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049411.scexe"],"md5sum":"e7dabb71c9e4984b7cffb973cae18195","name":"firmware-hdd-8a7ecf7465-HPD4-2.1.x86_64.rpm","release":"2021-08-31T10:35:13","revision":"0","sha1sum":"74f42a4ed3cfe7f767aa180b84b3723ce3de47c0","size":"4MB","target_guids":["002340a5-5600-304b-3430-304a45414244","002340a5-5600-304b-3830-304a45414245","002340a5-5600-314f-3630-304a45414246"],"type_of_change":"2","version":"HPD4"}],"id":{"product":"aeed5dab678d4be3a85806ba9711f37a","version":"a8e5fedf57aa4cbbab1bd27ca10d0cb1"},"installation":{"command":"CP031688.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK0400JEABD, VK0800JEABE, and VO1600JEABF Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VK0400JEABD、VK0800JEABEおよびVO1600JEABFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VO1600JEABF","target_guid":"002340a5-5600-314f-3630-304a45414246","type":"sas"},{"id":"VK0400JEABD","target_guid":"002340a5-5600-304b-3430-304a45414244","type":"sas"},{"id":"VK0800JEABE","target_guid":"002340a5-5600-304b-3830-304a45414245","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-30T10:24:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>If Power On Hours exceeds 70,000hrs, PM2R will report Hardware error (04/4C/A8) after the next Power Cycle and will not accept read/write commands. This fix will update storage location reporting when the maximum number of registrations in the Work Load Log read process reaches 70,000; the last registered 70,000th storage location will be modified to be read as the next (70,001st) storage location.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111296en_us</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>If Power On Hours exceeds 70,000hrs, PM2R will report Hardware error (04/4C/A8) after the next Power Cycle and will not accept read/write commands. This fix will update storage location reporting when the maximum number of registrations in the Work Load Log read process reaches 70,000; the last registered 70,000th storage location will be modified to be read as the next (70,001st) storage location.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111296en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK0400JEABD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO1600JEABF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VK0800JEABE","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This package updates the I/O module firmware on HPE D6020 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"5010776","datemodified":"2021-09-14T14:31:28","file_list":["Config.xml","cp048697.xml","cpqsetup.exe","Microsoft.VC90.CRT.manifest","msvcp110.dll","msvcp90.dll","msvcr110.dll","msvcr90.dll","payload.json","Tormore-Release-2.74-build-001.bin","VDUFlash.dll"],"md5sum":"45dc49c447454d38320d4382d1a6fb3b","name":"cp048697.exe","release":"2021-09-14T14:29:51","revision":"0","sha1sum":"af5a690c04342035170cb9140f6d3c67de53b963","size":"4MB","target_guids":[],"type_of_change":"1","version":"2.74"}],"id":{"product":"7a516f063c54466fad36c63290358155","version":"4ac003f4aaa545838547568bc8b3ba9f"},"installation":{"command":"cpqsetup.exe","command_params":"/tD6020 /v2.74 /iTormore-Release-2.74-build-001.bin /lD6020.log","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":720,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Windows Smart Component Installation Instructions:</strong></p>\n\n<p>This is a self extracting executable module. One can execute this module via the&nbsp;command line console or from&nbsp;Windows graphical user interface.</p>\n\n<p><strong>GUI Option:</strong></p>\n\n<ol>\n\t<li>Place the downloaded firmware package in a temporary directory.</li>\n\t<li>Using Windows Explorer, navigate to the directory containing the download.</li>\n\t<li>Double click the executable file.</li>\n\t<li>Follow onscreen instructions.</li>\n</ol>\n\n<p><strong>CLI Option:</strong></p>\n\n<p>Execute the Smart Component by entering the following command: CP0xxxxx.exe /s</p>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp;</p>\n\n<p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong>&nbsp;&nbsp;</p>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages.</li>\n\t<li>Run the launch_sum.bat in the root of the ISO.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n\n<p><strong>NOTES:&nbsp;</strong>OPTIONS for in band enclosure flash:</p>\n\n<p><strong>Parameter</strong>&nbsp;&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<strong>Description</strong><br />\n-----------------------------------------------------------------------------<br />\n<strong>/h,/?&nbsp;</strong>&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;Displays command line usage help(dialog box)<br />\n<strong>/s&nbsp;</strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Installs without user interaction</p>\n\n<p><strong>The following command&nbsp;is&nbsp;applicable only with /s:</strong><br />\n<strong>/f&nbsp;</strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Allow a downgrade or reinstall if already up to date</p>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p155944634/v202900/20-D6020-Gen9RN274J-ED1.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component for Windows (x64)"}],"prerequisites":{"required_diskspace":{"size_kb":"2"},"supported_devices":[{"id":"D6020","target_guid":"","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-17T13:09:27","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p>\n\n<ul>\n\t<li>Temperature sensors logic inside gSEP model and SES database</li>\n\t<li>When an IOM is pulled the surviving IOM reports false critical temperatures</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p155944634/v202900/20-D6020-Gen9RN274J-ED1.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"}],"sw_keys":[{"name":"D6020","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Blade Emulex 10/20GbE Server Adapters running under VMware vSphere 6.5."},{"lang":"ja","x_late":"この製品には、VMware vSphere 6.5で動作するHPE Blade Emulex 10/20GbEサーバーアダプター用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;12.0.1216.4.</p>\n"}],"files":[{"bytes":"358890","datemodified":"2020-02-05T16:23:11","file_list":["/cp042919.xml","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/elxnet-12.0.1216.4-1OEM.650.0.0.4598673.x86_64.vib","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/doc/README.txt","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/doc/release_note_elxnet_12.0.1216.4-1OEM.650.0.0.4598673.txt","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/index.xml","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/vendor-index.xml","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/metadata.zip","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/vib20/elxnet/EMU_bootbank_elxnet_12.0.1216.4-1OEM.650.0.0.4598673.vib","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/metadata.zip/vmware.xml","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-elxnet-12.0.1216.4.xml","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/metadata.zip/vibs/elxnet--643300737.xml"],"md5sum":"073093bafe630e1dc71c1395a11fe424","name":"cp042919.zip","release":"2020-02-05T22:23:05","revision":"0","sha1sum":"9d045e2340350da0b9dd8e812c582e52a8c4108a","size":"350KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecbc5a6557"],"type_of_change":"0","version":"2020.03.09","vib_list":[{"name":"elxnet","version":"12.0.1216.4-1OEM.650.0.0.4598673"}]}],"id":{"product":"4af400bbe27947109ef9222bacd0d2fd","version":"51edc3e8ce5e4b15a197316085ddafe6"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE Driver for VMware vSphere 6.5"},{"lang":"ja","x_late":"HPE Blade Emulex 10/20GbEドライバーfor VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-03-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product corrects&nbsp;a vmnic flapping issue which impacts network&nbsp;connectivity.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"elxnet:12.0.1216.4-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000400JWUFT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57554654","Version":"HPD3"},{"DeviceName":"MO000800JWUFU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57554655","Version":"HPD3"},{"DeviceName":"MO001600JWUFV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57554656","Version":"HPD3"},{"DeviceName":"MO003200JWUGA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57554741","Version":"HPD3"},{"DeviceName":"MO006400JWUGB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a57554742","Version":"HPD3"},{"DeviceName":"EO000400JWUGC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57554743","Version":"HPD3"},{"DeviceName":"EO000800JWUGD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57554744","Version":"HPD3"},{"DeviceName":"EO001600JWUGE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57554745","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MO000400JWUFT、MO000800JWUFU、MO001600JWUFV、MO003200JWUGA、MO006400JWUGB、EO000400JWUGC、EO000800JWUGD、およびEO001600JWUGE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE Drives</p>\n\n<p><br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD1<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16958703","datemodified":"2021-08-27T07:25:42","file_list":["/CP048397_BUILD_2.data","/CP048397.vmexe","/CP048397.vmexe64","/CP048397.vmfile","/CP048397_VMw.zip","/CP048397.xml","/payload.json","/CP048397_VMw.zip/index.xml","/CP048397_VMw.zip/vendor-index.xml","/CP048397_VMw.zip/metadata.zip","/CP048397_VMw.zip/vib20/CP048397/HPE_bootbank_CP048397_HPD3.2-7.0.0.15843807.vib","/CP048397_VMw.zip/metadata.zip/vendor-index.xml","/CP048397_VMw.zip/metadata.zip/vmware.xml","/CP048397_VMw.zip/metadata.zip/vibs/CP048397--9205879085268121126.xml","/CP048397_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048397_HPD3.2-7.0.0.15843807.xml"],"md5sum":"ca4a64bb4bf915e8761407203db95de2","name":"CP048397.zip","release":"2021-08-27T07:20:12","revision":"0","sha1sum":"4d2ca6b2575422fca8735c46905402dbe121cf4d","size":"16MB","target_guids":["4d2340a5-304f-3030-3430-304a57554654","4d2340a5-304f-3030-3830-304a57554655","4d2340a5-304f-3130-3630-304a57554656","4d2340a5-304f-3330-3230-304a57554741","4d2340a5-304f-3630-3430-304a57554742","452340a5-304f-3030-3430-304a57554743","452340a5-304f-3030-3830-304a57554744","452340a5-304f-3130-3630-304a57554745"],"type_of_change":"1","version":"HPD3","vib_list":[{"name":"CP048397","version":"HPD3.2-7.0.0.15843807"}]}],"id":{"product":"d7a820130b1346d2a8d4377d479232cf","version":"f5efc4476fb74e2e9d51d7755e922554"},"installation":{"command":"CP040692.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>Additional information to execute VIB file.</strong></p>\n\n<p><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p>             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul>\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p> </p>\n\n<p><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul>\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul>\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE  Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MO000400JWUFT、MO000800JWUFU、MO001600JWUFV、MO003200JWUGA、MO006400JWUGB、EO000400JWUGC、EO000800JWUGD、およびEO001600JWUGEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MO006400JWUGB","target_guid":"4d2340a5-304f-3630-3430-304a57554742","type":"sas"},{"id":"MO003200JWUGA","target_guid":"4d2340a5-304f-3330-3230-304a57554741","type":"sas"},{"id":"MO001600JWUFV","target_guid":"4d2340a5-304f-3130-3630-304a57554656","type":"sas"},{"id":"EO001600JWUGE","target_guid":"452340a5-304f-3130-3630-304a57554745","type":"sas"},{"id":"MO000800JWUFU","target_guid":"4d2340a5-304f-3030-3830-304a57554655","type":"sas"},{"id":"EO000800JWUGD","target_guid":"452340a5-304f-3030-3830-304a57554744","type":"sas"},{"id":"MO000400JWUFT","target_guid":"4d2340a5-304f-3030-3430-304a57554654","type":"sas"},{"id":"EO000400JWUGC","target_guid":"452340a5-304f-3030-3430-304a57554743","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T17:17:19","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EO000800JWUGD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200JWUGA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO001600JWUGE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000400JWUGC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600JWUFV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000400JWUFT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800JWUFU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO006400JWUGB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900083","languages":[{"lang":"tw","x_late":"韌體 ─ 電源管理"},{"lang":"en","x_late":"Firmware - Power Management"},{"lang":"ko","x_late":"펌웨어 - 전원 관리"},{"lang":"ja","x_late":"ファームウェア - パワー マネジメント"},{"lang":"cn","x_late":"固件 - 电源管理"}]}],"description":[{"lang":"tw","x_late":"此元件可更新 HPE Gen9 伺服器上的進階功率限定微控制器韌體。"},{"lang":"en","x_late":"This component updates the  Advanced Power Capping Microcontroller Firmware for HPE Gen9 Servers"},{"lang":"ko","x_late":"이 구성 요소는 HPE Gen9 서버의 고급 전원 캐핑 마이크로컨트롤러 펌웨어를 업데이트합니다."},{"lang":"cn","x_late":"该组件可更新用于 HPE Gen9 服务器的高级功率封顶微控制器固件"},{"lang":"ja","x_late":"このコンポーネントは、アドバンスト消費電力上限マイクロコントローラーファームウェア for HPE Gen9サーバーをアップデートします"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"551616","datemodified":"2018-10-04T15:53:26","file_list":["cp037781.xml","cpqsetup.exe","cpqsysio64.sys","PICGen9_1.0.9s.hex","SignedImageInstaller64.dll"],"md5sum":"43e10003f21256b4394da0184657a611","name":"cp037781.exe","release":"2018-11-05T00:00:00","revision":"1","sha1sum":"12d4158d8a4830d6df28229489fb1802238b4742","size":"538KB","target_guids":[],"type_of_change":"0","version":"1.0.9(I)"}],"id":{"product":"fdcd2417f5b44570a83d4b1a96ea2478","version":"713c43e07cd74641a292dcc844f52f57"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired components&nbsp;to be updated in the directory, \\packages on the USB key. To use with HPE SUM 7.6.0 or earlier, place the components in \\hp\\swpackages on the USB Key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.&nbsp;<br />\n&nbsp;</p>\n\n<p>This component can only be executed on Windows x64.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.      同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。HPE SUM 7.6.0またはそれ以前のバージョンを使用するには、\\hp\\swpackages内のコンポーネントをUSBキーにコピーしてください。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。 <br />\n </p>\n\n<p>このコンポーネントは、Windows x64上でのみ実行できます。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Windows x64 的 ROM 線上更新 - 適用於 HPE Gen9 伺服器的進階功率限定微控制器韌體"},{"lang":"en","x_late":"Online ROM Flash for Windows x64 - Advanced Power Capping Microcontroller Firmware for HPE Gen9 Servers"},{"lang":"ko","x_late":"Windows x64용 온라인 ROM 플래시 - HPE Gen9 서버의 고급 전원 캐핑 마이크로컨트롤러 펌웨어"},{"lang":"cn","x_late":"用于 Windows x64 的在线 ROM 刷新 - 用于 HPE Gen9 服务器的高级功率封顶微控制器固件"},{"lang":"ja","x_late":"オンラインROMフラッシュ for Windows  x64  - アドバンスト消費電力上限マイクロコントローラーファームウェア for HPE Gen9サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"6","minor":"0","name":"Microsoft Windows Server 2008 x64","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows 8.1 (64-bit)","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"1","name":"Microsoft Windows 7 (64-bit) - All Editions","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-02T05:54:09","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<P><B>Important Notes:</B></P>Ver. 1.0.9(I) contains updates to the component packaging and is functionally equivalent to ver. 1.0.9.  It is not necessary to upgrade with Revision I if a previous component Revision was used to upgrade the firmware to version 1.0.9.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>Addresses an issue in which the minimum power capping value was incorrectly being calculated on certain systems.  This fix increases the accuracy of the minimum capping value set during POST.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<P><B>Important Notes:</B></P>Ver. 1.0.9(I) contains updates to the component packaging and is functionally equivalent to ver. 1.0.9.  It is not necessary to upgrade with Revision I if a previous component Revision was used to upgrade the firmware to version 1.0.9.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>Addresses an issue in which the minimum power capping value was incorrectly being calculated on certain systems.  This fix increases the accuracy of the minimum capping value set during POST.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U16","value":"HP ProLiant SE2160w Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"FTP","value":"FTP-Only System"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U19","value":"HPE ProLiant XL420 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"}],"sw_keys":[{"name":"PowerPIC-Gen9","sw_key_expectedpath":"firmware:sd:powerpic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000GFJTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGNTG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-3047464a5445","Version":"HPG5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MM1000GFJTE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MM1000GFJTE Drive</p>\n\n<p><strong><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br />\n<br />\n<strong><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4<br />\n<br />\n<strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4<br />\n<br />\n<strong><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3553912","datemodified":"2021-07-25T16:51:56","file_list":["cp048623.xml","cpqsetup.exe","payload.json","SAVGNTG5.rel","setup.dll"],"md5sum":"625499ba8fd566c7e78713914d4108b8","name":"cp048623.exe","release":"2021-07-25T16:44:05","revision":"0","sha1sum":"60a06da60b71a0e0ef3b9c0def0464da75f26cda","size":"3MB","target_guids":["002340a5-4d00-314d-3030-3047464a5445"],"type_of_change":"0","version":"HPG5"}],"id":{"product":"4106b2f5d7c1411c95e94d52dff63df7","version":"d41d13114060474a9ee817bf0d9588b0"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MM1000GFJTE Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MM1000GFJTEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MM1000GFJTE","target_guid":"002340a5-4d00-314d-3030-3047464a5445","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T13:04:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MM1000GFJTE","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300032","languages":[{"lang":"fr","x_late":"Pilote - Gestion du système"},{"lang":"en","x_late":"Driver - System Management"},{"lang":"cn","x_late":"驱动程序 - 系统管理"},{"lang":"tw","x_late":"驅動程式 ─ 系統管理"},{"lang":"de","x_late":"Treiber - Systemverwaltung"},{"lang":"ko","x_late":"드라이버 - 시스템 관리"},{"lang":"it","x_late":"Driver - Gestione sistema"},{"lang":"ja","x_late":"ドライバ - システム マネジメント"},{"lang":"es","x_late":"Controlador - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The iLO 4 Channel Interface Driver allows software to communicate with the iLO 4 management controller.  The driver is used by the ProLiant Health Monitor, Insight Management Agents and WBEM Providers, Agentless Management Service, and other utilities."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[],"files":[{"bytes":"616376","datemodified":"2019-07-19T13:44:47","file_list":["cp039985.xml","CpqCi.dll","cpqsetup.exe","cpqsmif.dll","generic.dll","hpqilo3chif.sys","hpqilo3chif2016.cat","hpqilo3chif2016.inf","install.xml"],"md5sum":"18b932b5ca66e3992f94fae9ec3e9d5e","name":"cp039985.exe","release":"2019-07-19T13:43:05","revision":"0","sha1sum":"0dde40b96982bdf38b6951632958856a8b3514f6","size":"601KB","target_guids":[],"type_of_change":"0","version":"4.1.0.0"}],"id":{"product":"cef186d7aeff4c8eb2518a5d81c00613","version":"58284ae214af415c9547f8c8ddca851f"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Place the Smart Component in a temporary directory, then double-click it to run.<p>Select \"Install\" to start extracting to a temporary location on the hard drive.   <p>Click the \"Install\" button to perform the driver installation."},{"lang":"ja","x_late":"Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。<p>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。   <p>インストールボタンをクリックしてドライバーインストールを実行します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"iLO 4 Channel Interface Driver for Windows Server 2016 and Server 2019"},{"lang":"ja","x_late":"iLO 4チャネルインターフェースドライバー for Windows Server 2016 および Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3307","subdev":"1979","subven":"103C","target_guid":"","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-09-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Add support for Windows Server 2019.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Corrected a potential Windows bugcheck 0x50 (PAGE_FAULT_IN_NONPAGED_AREA) that could occur if Windows restarts the driver without unloading it.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"}],"sw_keys":[{"name":"hpqilo3chif.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VS000480KXALB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"85031G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3030-3438-304b58414c42","Version":"85031G00"},{"DeviceName":"VS000960KWXFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"85031G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3030-3936-304b5758464e","Version":"85031G00"},{"DeviceName":"VS001920KWXFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"85031G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3130-3932-304b57584650","Version":"85031G00"},{"DeviceName":"VS003840KWXFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"85031G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3330-3834-304b57584651","Version":"85031G00"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following NVME drive models: VS000480KXALB, VS000960KWXFN, VS001920KWXFP and VS003840KWXF"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のNVMEドライブモデルのファームウェアを提供します。VS000480KXALB、VS000960KWXFN、VS001920KWXFP、およびVS003840KWXF"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows (x64) - VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>85031G00</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;&nbsp;85030G00</p>\n\n<p><strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>&nbsp;85030G00</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Enhancements/New Features:&nbsp;</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<ul>\n\t<li>Requires iLO5 v2.30 or later, SUM will not detect SSD as applicable for Firmware update for deployment with iLO version older than v2.30</li>\n</ul>\n"}],"files":[{"bytes":"5291120","datemodified":"2021-07-20T12:51:09","file_list":["85031G00_mp.bin","cp049054.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll"],"md5sum":"3c50c2e93584b4ca7025ccc9501218a4","name":"cp049054.exe","release":"2021-09-24T00:00:00","revision":"1","sha1sum":"8d9afb21b23ee6ef52c50a3c4d7c77668ff222eb","size":"5MB","target_guids":["562340a5-3053-3030-3438-304b58414c42","562340a5-3053-3030-3936-304b5758464e","562340a5-3053-3130-3932-304b57584650","562340a5-3053-3330-3834-304b57584651"],"type_of_change":"1","version":"85031G00"}],"id":{"product":"15c5494e659e4865b78e60077bae7860","version":"aef9bb7cdcc849ec9f032e51a9bd3c7d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the&nbsp;</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em>&nbsp;script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/jp/servers/spp_dl\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) - VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - VS000480KXALB、VS003840KWXFQ、VS001920KWXFP、およびVS000960KWXFNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VS000480KXALB","target_guid":"562340a5-3053-3030-3438-304b58414c42","type":"nvme"},{"dev":"2241","subdev":"02F6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1b4b-2241159002f6","type":"pci","ven":"1B4B"},{"id":"VS003840KWXFQ","target_guid":"562340a5-3053-3330-3834-304b57584651","type":"nvme"},{"id":"VS001920KWXFP","target_guid":"562340a5-3053-3130-3932-304b57584650","type":"nvme"},{"id":"VS000960KWXFN","target_guid":"562340a5-3053-3030-3936-304b5758464e","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-11-01T10:37:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"VS003840KWXFQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VS000960KWXFN","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VS001920KWXFP","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VS000480KXALB","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000GCWLT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HMKPB6G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304743574c54","Version":"HPG4"},{"DeviceName":"MB3000GCWLU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HMKPB6G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304743574c55","Version":"HPG4"},{"DeviceName":"MB4000GCWLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HMKPB6G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304743574c56","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SATA drive models: MB2000GCWLT, MB3000GCWLU, and MB4000GCWLV Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。MB2000GCWLT、MB3000GCWLU、およびMB4000GCWLVドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB2000GCWLT, MB3000GCWLU&nbsp;and MB4000GCWLV Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5182136","datemodified":"2021-07-23T06:13:20","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-2e70ce7412-HPG4-10.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e70ce7412-HPG4-10.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e70ce7412-HPG4-10.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e70ce7412-HPG4-10.1/CP048148.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e70ce7412-HPG4-10.1/HMKPB6G4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e70ce7412-HPG4-10.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e70ce7412-HPG4-10.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e70ce7412-HPG4-10.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e70ce7412-HPG4-10.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048148.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048148.scexe"],"md5sum":"0b23095a0158518cef6ccd3aac22587f","name":"firmware-hdd-2e70ce7412-HPG4-10.1.x86_64.rpm","release":"2021-07-23T06:00:10","revision":"0","sha1sum":"6d5be39253a2e9d103502065e01cf8400f5bad8f","size":"4MB","target_guids":["002340a5-4d00-3242-3030-304743574c54","002340a5-4d00-3342-3030-304743574c55","002340a5-4d00-3442-3030-304743574c56"],"type_of_change":"1","version":"HPG4"}],"id":{"product":"75970c81b36f443fbbff409af0bea2a1","version":"549d2cecda784500a5832eb59aadaf16"},"installation":{"command":"CP040289.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB2000GCWLT, MB3000GCWLU and MB4000GCWLV Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB2000GCWLT、MB3000GCWLUおよびMB4000GCWLVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"MB2000GCWLT","target_guid":"002340a5-4d00-3242-3030-304743574c54","type":"sata"},{"id":"MB3000GCWLU","target_guid":"002340a5-4d00-3342-3030-304743574c55","type":"sata"},{"id":"MB4000GCWLV","target_guid":"002340a5-4d00-3442-3030-304743574c56","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-26T18:45:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000GCWLV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB2000GCWLT","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB3000GCWLU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains iSCSI drivers for the HPE Blade Emulex 10/20GbE Server Adapters running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Blade Emulex 10/20GbEサーバーアダプター用のiSCSIドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"978905","datemodified":"2021-03-08T20:16:34","file_list":["./lib/modules/4.12.14-195-default","./lib/modules/4.12.14-195-default/updates","./lib/modules/4.12.14-195-default/updates/be2iscsi","./lib/modules/4.12.14-195-default/updates/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/be2iscsi_bl-kmp-default/component.xml"],"md5sum":"6a3c58bf25de820d0d57cd829268fb3b","name":"be2iscsi_bl-kmp-default-12.0.1342.0_k4.12.14_195-1.sles15sp1.x86_64.rpm","release":"2021-03-08T20:03:04","revision":"0","sha1sum":"8b5de4adc1f362a2760a7c9eaddcad4810e483e2","size":"955KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf6b47a9e"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"1050641","datemodified":"2021-03-08T20:22:21","file_list":["./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/be2iscsi","./lib/modules/5.3.18-22-default/updates/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/be2iscsi_bl-kmp-default/component.xml"],"md5sum":"f7e0721ba79cc0efd1cce3dd9ea099b9","name":"be2iscsi_bl-kmp-default-12.0.1342.0_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-03-08T20:03:04","revision":"0","sha1sum":"9851f2e3917fa0b45efdf331c67a3cb7e2347bc9","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf6b47a9e"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"86e4b3a553494874939d56f97075cb67","version":"cf72dc2669f74c42816776cc86d25202"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE iSCSI Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE Blade Emulex 10/20GbE iSCSIドライバー for SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0722","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-03-19T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>These drivers have been&nbsp;updated to maintain compatibility with the latest firmware.</p>\n","latest_fixes_x_late":"<p>These drivers have been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 15 SP2.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"be2iscsi_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2iscsi_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2iscsi_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2iscsi_bl-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXn0HPD7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57485050","Version":"HPD7"},{"DeviceName":"EH000600JWHPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXn0HPD7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5748504e","Version":"HPD7"},{"DeviceName":"EH000300JWHPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXn0HPD7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5748504c","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EH000900JWHPP, EH000600JWHPN and EH000300JWHPL"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EH000900JWHPP、EH000600JWHPN および EH000300JWHPL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3000856","datemodified":"2021-07-26T18:36:44","file_list":["cp049138.xml","cpqsetup.exe","payload.json","setup.dll","TA14SXn0HPD7.REL"],"md5sum":"b5cfed5a3fbe3d6d348758141b0311f6","name":"cp049138.exe","release":"2021-07-26T18:28:05","revision":"0","sha1sum":"0426ee61e3eb0e839d4afd2dfa1d2b9ef42c0b10","size":"2MB","target_guids":["452340a5-3048-3030-3930-304a57485050","452340a5-3048-3030-3630-304a5748504e","452340a5-3048-3030-3330-304a5748504c"],"type_of_change":"1","version":"HPD7"}],"id":{"product":"0a96bc740aee4364b774edfa452ca9a4","version":"db2ca8b92ea7413b9919b1a5dd582fac"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration-line: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EH000900JWHPP、EH000600JWHPNおよびEH000300JWHPLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EH000300JWHPL","target_guid":"452340a5-3048-3030-3330-304a5748504c","type":"sas"},{"id":"EH000600JWHPN","target_guid":"452340a5-3048-3030-3630-304a5748504e","type":"sas"},{"id":"EH000900JWHPP","target_guid":"452340a5-3048-3030-3930-304a57485050","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T18:06:49","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH000900JWHPP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000300JWHPL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000600JWHPN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE QLogic NX2 10Gb and 20Gb Multifunction Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE QLogic NX2 10Gbおよび20GbマルチファンクションGigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"7483585","datemodified":"2021-08-11T16:09:44","file_list":["./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/5.3.18-57-default","./lib/modules/5.3.18-57-default/updates","./lib/modules/5.3.18-57-default/updates/bnx2.ko","./lib/modules/5.3.18-57-default/updates/bnx2fc.ko","./lib/modules/5.3.18-57-default/updates/bnx2i.ko","./lib/modules/5.3.18-57-default/updates/bnx2x.ko","./lib/modules/5.3.18-57-default/updates/cnic.ko","./usr/share/smartupdate/netxtreme2-kmp-default/component.xml"],"md5sum":"63d4007a0cb870ba4a52f024ff243fc9","name":"netxtreme2-kmp-default-7.14.80_k5.3.18_57-6.sles15sp3.x86_64.rpm","release":"2021-08-11T15:47:11","revision":"0","sha1sum":"0970249ab726d1ad6652c8192a2715c0549d6b38","size":"7MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec41a44bbb"],"type_of_change":"0","version":"7.14.80-6"},{"bytes":"7315119","datemodified":"2021-08-11T16:11:11","file_list":["./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/bnx2.ko","./lib/modules/5.3.18-22-default/updates/bnx2fc.ko","./lib/modules/5.3.18-22-default/updates/bnx2i.ko","./lib/modules/5.3.18-22-default/updates/bnx2x.ko","./lib/modules/5.3.18-22-default/updates/cnic.ko","./usr/share/smartupdate/netxtreme2-kmp-default/component.xml"],"md5sum":"c2cf85f7e3180609bab76041b7f47a9f","name":"netxtreme2-kmp-default-7.14.80_k5.3.18_22-6.sles15sp2.x86_64.rpm","release":"2021-08-11T15:47:11","revision":"0","sha1sum":"1e77e16f10f6745107df58984ccf8fa94d6d455f","size":"6MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec41a44bbb"],"type_of_change":"0","version":"7.14.80-6"}],"id":{"product":"eafab624995d485096ba1119b617b464","version":"c1ae90ec0abf413d81f76e73eda4eb73"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>Download README for any additional installation instructions.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE QLogic NX2 10/20 GbE Multifunction Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE QLogic NX2 10/20 GbEマルチファンクションドライバー for SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"168E","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c339d","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c18d3","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1930","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c193a","type":"pci","ven":"14E4"},{"dev":"16A1","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a1159000ec","type":"pci","ven":"1077"},{"dev":"16AF","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c339d","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c18d3","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c193a","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1930","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1933","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1931","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1917","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"3382","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c3382","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c339d","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c193a","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1930","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16ad159000ec","type":"pci","ven":"1077"},{"dev":"16A4","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a4159000ec","type":"pci","ven":"1077"},{"dev":"16AE","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1931","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16af15908148","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ae15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-168e15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1931","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 15 Service Pack 2</p>\n","latest_fixes_x_late":"<p>This product corrects an issue obtain Medium Dependent Interface(MDI) and Medium Dependent Interface Crossover (MDIX) information when execution ethtool tools</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>This product now supports MDI(Medium Dependent Interface)/MDIX(Medium Dependent Interface Crossover) connection status to ethtool.</li>\n\t<li>This product now supports Timestamping the unicast Precision Time Protocol (PTP) packets.</li>\n\t<li>This product now supports&nbsp;SUSE Linux Enterprise Server 15 Service Pack 3</li>\n</ul>\n","curr_fixes_x_late":"<p>This product addresses an issue where Virtual Local Area Networks(VLANs) resource accounting when linux driver creating 272 Virtual Local Area Networks(VLANs) on single Virtual Functions, then enable interface after closed.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"netxtreme2-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"netxtreme2-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"netxtreme2-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"netxtreme2-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HP FlexFabric 10Gb 2-port 534M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C1933","Version":"7.18.82"},{"DeviceName":"HP FlexFabric 10Gb 2-port 536FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16A2103C22FA","Version":"7.18.82"},{"DeviceName":"HP FlexFabric 20Gb 2-port 630M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16A2103C1917","Version":"7.18.82"},{"DeviceName":"HPE FlexFabric 20Gb 2-port 630FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16A2103C1916","Version":"7.18.82"},{"DeviceName":"HP NPAR 10Gb 2-port 534M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C1933","Version":"7.18.82"},{"DeviceName":"HP NPAR 10Gb 2-port 536FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16A4103C22FA","Version":"7.18.82"},{"DeviceName":"HP NPAR 20Gb 2-port 630FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16A4103C1916","Version":"7.18.82"},{"DeviceName":"HP NPAR 20Gb 2-port 630M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16A4103C1917","Version":"7.18.82"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Blade QLogic NX2 Gigabit Ethernet NICs Boot code, PXE, NCSI, iSCSI, FCoE and CCM code running under Microsoft Windows Server 2012 R2, Windows Server 2016 and Windows Server 2019."},{"lang":"ja","x_late":"このパッケージには、Windows Server 2012 R2、Windows Server 2016、およびWindows Server 2019で動作するHPE Blade QLogic NX2 Gigabit Ethernet NICブートコード、PXE、NCSI、iSCSI、FCoEおよびCCMコードをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains combo image v7.18.82 with the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"2\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>NIC</strong></td>\n\t\t\t<td><strong>Boot Code Version</strong></td>\n\t\t\t<td><strong>PXE Version</strong></td>\n\t\t\t<td><strong>UEFI Version</strong></td>\n\t\t\t<td><strong>iSCSI Version</strong></td>\n\t\t\t<td><strong>FCoE Version</strong></td>\n\t\t\t<td><strong>CCM Version</strong></td>\n\t\t\t<td><strong>L2 Version</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HP FlexFabric 10Gb 2-port 534M Adapter<br />\n\t\t\tHP FlexFabric 10Gb 2-port 536FLB Adapter<br />\n\t\t\tHP FlexFabric 20Gb 2-port 630FLB Adapter<br />\n\t\t\tHP FlexFabric 20Gb 2-port 630M Adapter</td>\n\t\t\t<td>7.16.03</td>\n\t\t\t<td>7.14.13</td>\n\t\t\t<td>8.9.0</td>\n\t\t\t<td>7.14.0</td>\n\t\t\t<td>7.14.3</td>\n\t\t\t<td>7.14.4</td>\n\t\t\t<td>7.12.25</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"4571024","datemodified":"2021-08-12T09:36:21","file_list":["BNICOFUT.pdf","cp047538.xml","cpqsetup.exe","FW/","FW/firmware.json","FW/hp_mbi_7.18.82.bin","ja/","ja/BNICOFUT_JA.pdf","LibQLGC_HpFwUpg.dll","OnlineFWUpgrade.dll","payload.json","QLMAPIa.dll","QLNICFWUpg.exe","tcl83.dll","zh-CN/","zh-CN/BNICOFUT_ZHCN.pdf"],"md5sum":"7803f69a89eab306b2cdd6007983708c","name":"cp047538.exe","release":"2021-08-12T09:27:07","revision":"0","sha1sum":"588c1debbf7f2e6d569f257482e0867d1de98c98","size":"4MB","target_guids":["a6b1a447-382a-5a4f-14E4-168E103C1933","a6b1a447-382a-5a4f-14E4-16A2103C22FA","a6b1a447-382a-5a4f-14E4-16A2103C1917","a6b1a447-382a-5a4f-14E4-16A2103C1916","a6b1a447-382a-5a4f-14E4-16AE103C1933","a6b1a447-382a-5a4f-14E4-16A4103C22FA","a6b1a447-382a-5a4f-14E4-16A4103C1916","a6b1a447-382a-5a4f-14E4-16A4103C1917"],"type_of_change":"0","version":"1.0.5.3"}],"id":{"product":"7ba136be4b834a5699f5c5fff754d07b","version":"9620e2bf90f84816a023fc2830fee22e"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic NX2 10/20 GbE Multifunction Driver version 7.13.165.0 or greater is required and should be already active","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec9bc6b74c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.13.165.0","description":"HPE QLogic NX2 10/20 GbE Multifunction Driver version 7.13.165.0 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<BR>\n<P>From that drive and directory, execute the downloaded file. <BR>\n<P>Click the \"Install\" button to proceed with the installation.</P>\n<P>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</P>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<BR>\n<P>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<BR>\n<P>［インストール］ボタンをクリックして、インストールを開始します。</P>\n<P>アップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</P>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade QLogic NX2 Online Firmware Upgrade Utility for Windows Server x64 Editions"},{"lang":"ja","x_late":"HPE Blade QLogic NX2オンラインファームウェアアップグレードユーティリティ for Windows Server x64 Editions"}],"prerequisites":{"required_diskspace":{"size_kb":"5400"},"supported_devices":[{"dev":"168E","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1933","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c22fa","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1917","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1916","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1933","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c22fa","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1916","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1917","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-03T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product addresses an issue where powering on the system with any I/O virtualization functionality (NPAR, SR-IOV, etc) enabled results in an Uncorrectable Machine Check Exception (UMCE).<br />\nThis product addresses an issue where the WOL option is displayed on the Human Interface Infrastructure (HII) menu for 534M and 630M mezzanine devices, even though WOL is not supported on those devices.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product addresses an issue where the Maximum Transmission Unit (MTU) value of iSCSI function port is displayed as 0 bytes in AHS log.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"QlNicFwUpg.exe","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO0400JFFCF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3430-304a46464346","Version":"HPD9"},{"DeviceName":"MO0800JFFCH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3830-304a46464348","Version":"HPD9"},{"DeviceName":"MO1600JFFCK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304a4646434b","Version":"HPD9"},{"DeviceName":"MO3200JFFCL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-334f-3230-304a4646434c","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MO0400JFFCF, MO0800JFFCH, MO1600JFFCK and MO3200JFFCL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MO0400JFFCF, MO0800JFFCH, MO1600JFFCK&nbsp;and MO3200JFFCL Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD9</p>\n\n<p><strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD8</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD8</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong> None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"16599527","datemodified":"2021-08-27T12:43:23","file_list":["/CP048439_BUILD_3.data","/CP048439.vmexe","/CP048439.vmexe64","/CP048439.vmfile","/CP048439_VMw.zip","/CP048439.xml","/payload.json","/CP048439_VMw.zip/index.xml","/CP048439_VMw.zip/vendor-index.xml","/CP048439_VMw.zip/metadata.zip","/CP048439_VMw.zip/vib20/CP048439/HPE_bootbank_CP048439_HPD9.3-7.0.0.15843807.vib","/CP048439_VMw.zip/metadata.zip/vendor-index.xml","/CP048439_VMw.zip/metadata.zip/vmware.xml","/CP048439_VMw.zip/metadata.zip/vibs/CP048439-7103474675442070464.xml","/CP048439_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048439_HPD9.3-7.0.0.15843807.xml"],"md5sum":"fd1af67cc18ef29e7d89ee36d2b5dcac","name":"CP048439.zip","release":"2021-08-27T12:38:09","revision":"0","sha1sum":"b56c2e0497909ee4c8cf2a88ff9235c35ed5f165","size":"15MB","target_guids":["002340a5-4d00-304f-3430-304a46464346","002340a5-4d00-304f-3830-304a46464348","002340a5-4d00-314f-3630-304a4646434b","002340a5-4d00-334f-3230-304a4646434c"],"type_of_change":"1","version":"HPD9","vib_list":[{"name":"CP048439","version":"HPD9.3-7.0.0.15843807"}]}],"id":{"product":"4e3d7926d2c648d2b99239bbce77f310","version":"6ed633d59ccd483ab1d82d0ecea8b2ff"},"installation":{"command":"CP042779.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします。</li>\n\t<li>CPXXXXXX.vmexe(ESXi 6.7 &以前のバージョン)およびCPXXXXXX.vmexe64(ESXi 7.0)は、次のコマンドを使用して実行可能です:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod x CPXXXXXX.vmexe    または    chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPXXXXXX.vmexe(または)./CPXXXXXX.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MO0400JFFCF, MO0800JFFCH, MO1600JFFCK and MO3200JFFCL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MO0400JFFCF、MO0800JFFCH、MO1600JFFCK、およびMO3200JFFCLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MO1600JFFCK","target_guid":"002340a5-4d00-314f-3630-304a4646434b","type":"sas"},{"id":"MO3200JFFCL","target_guid":"002340a5-4d00-334f-3230-304a4646434c","type":"sas"},{"id":"MO0400JFFCF","target_guid":"002340a5-4d00-304f-3430-304a46464346","type":"sas"},{"id":"MO0800JFFCH","target_guid":"002340a5-4d00-304f-3830-304a46464348","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-10T11:39:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MO0800JFFCH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO3200JFFCL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO0400JFFCF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO1600JFFCK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX3Pro-rel-2_42_5700-764285-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F4","Version":"2.42.5700"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX3Pro-rel-2_42_5056-764283-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F2","Version":"2.42.5056"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX3Pro-rel-2_42_5056-764284-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F3","Version":"2.42.5056"},{"DeviceName":"HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX3Pro-rel-2_42_5000-764286-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F5","Version":"2.42.5000"},{"DeviceName":"HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX3Pro-rel-2_42_5000-764282-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F1","Version":"2.42.5000"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE VPI (Ethernet and Infiniband mode of operation) devices on Windows x86_64 platform. See the supported devices list in the Supported devices section."},{"lang":"ja","x_late":"このパッケージは、Windows x86_64プラットフォーム上でHPE VPI (EthernetおよびInfinibandモードで動作)デバイスをアップグレードするためのユーティリティおよびバイナリを含みます。 [サポートされるデバイス]セクションでサポートされるデバイスのリストを参照してください。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>InfiniBand Card Type</strong></td>\n\t\t\t<td><strong>Firmware&nbsp;Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+M Adapter (764282-B21)</td>\n\t\t\t<td>2.42.5000</td>\n\t\t\t<td>HP_1350110023</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+M Adapter (764283-B21)</td>\n\t\t\t<td>2.42.5056</td>\n\t\t\t<td>HP_1360110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+QSFP Adapter (764284-B21)</td>\n\t\t\t<td>2.42.5056</td>\n\t\t\t<td>HP_1370110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+FLR-QSFP Adapter (764285-B21)</td>\n\t\t\t<td>2.42.5700</td>\n\t\t\t<td>HP_1380110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+FLR-QSFP Adapter (764286-B21)</td>\n\t\t\t<td>2.42.5000</td>\n\t\t\t<td>HP_1390110023</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"15785992","datemodified":"2020-11-12T07:53:23","file_list":["cp045905.xml","cpqsetup.exe","fw-ConnectX3Pro-rel-2_42_5000-764282-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","fw-ConnectX3Pro-rel-2_42_5000-764286-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","fw-ConnectX3Pro-rel-2_42_5056-764283-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","fw-ConnectX3Pro-rel-2_42_5056-764284-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","fw-ConnectX3Pro-rel-2_42_5700-764285-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","i2cbrdg.dll","installer.dll","libcmdif-1.dll","libgcc_s_seh-1.dll","libmlxfwops-1.dll","libmtcr-1.dll","libreg_access-1.dll","libstdc++-6.dll","libwinpthread-1.dll","libxml2.dll","mdevices.exe","mst64.sys","mstflint.exe","payload.json","perl526.dll","zlib1.dll"],"md5sum":"feae578e4cc50a0ec032360edf98ab4b","name":"cp045905.exe","release":"2020-11-12T07:50:04","revision":"0","sha1sum":"11e9198d1258a0e94f559129217571e6c5919c4d","size":"15MB","target_guids":["a6b1a447-382a-5a4f-15B3-1007103C22F4","a6b1a447-382a-5a4f-15B3-1007103C22F2","a6b1a447-382a-5a4f-15B3-1007103C22F3","a6b1a447-382a-5a4f-15B3-1007103C22F5","a6b1a447-382a-5a4f-15B3-1007103C22F1"],"type_of_change":"1","version":"1.0.0.12"}],"id":{"product":"637d540b39214addb4d18ef0c3a8cbbf","version":"34bf979025e44dc3851a5dd91737e087"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.\n<p>\n From that drive and directory, execute the downloaded file.</p>\n<p>\n Click the Install button to proceed with the installation.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (Windows x64) for HPE Mellanox VPI (Ethernet and Infiniband mode) devices on Windows x86_64 platform"},{"lang":"ja","x_late":"オンラインファームウェアアップグレードユーティリティ (Windows x64) for HPE Mellanox VPI (EthernetおよびInfinibandモード)デバイス - Windows x86_64プラットフォーム"}],"prerequisites":{"required_diskspace":{"size_kb":"27000"},"supported_devices":[{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-10-16T19:30:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5000:</strong><br />\n&nbsp;&nbsp; &nbsp;764282-B21<br />\n&nbsp;&nbsp; &nbsp;764286-B21&nbsp;&nbsp;</p>\n\n<p><strong>Firmware for the following devices are updated to 2.42.5056:</strong><br />\n&nbsp;&nbsp; &nbsp;764283-B21<br />\n&nbsp;&nbsp;&nbsp;&nbsp;764284-B21</p>\n\n<p><strong>Firmware for the following device&nbsp;is&nbsp;updated to 2.42.5700:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;764285-B21</p>\n\n<p><strong>New features in firmware version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>Added support for the following features.\n\t<ul>\n\t\t<li>new TLV: CX3_GLOBAL_CONF to enable/disable timestamp on incoming packets through mlxconfig configuration.</li>\n\t\t<li>User MAC configuration.</li>\n\t\t<li>Automatically collecting mstdump before driver reset.</li>\n\t\t<li>A&nbsp;mechanism to detect DEAD_IRISC (plastic) from TPT (iron) and raise an assert.</li>\n\t\t<li>A new field is added to &quot;set port&quot; command which notifies the firmware what is the user_mtu size.</li>\n\t</ul>\n\t</li>\n\t<li>Improved the debug ability for command timeout cases.</li>\n</ul>\n\n<p><strong>New features and changes&nbsp;in firmware version 2.42.5700.</strong></p>\n\n<ul>\n\t<li>Modified the mlx_cmd_get_mlx_link_status command return value to return &quot;Link Type = Ethernet&quot; in Ethernet adapter cards.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Fixes in version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>PortRcvPkts counter was prevented from being cleared after&nbsp;resetting it.</li>\n\t<li>The system&nbsp;Timed Out on the configuration cycle of&nbsp;the Virtual Functions (VFs) when more than 10 Virtual Functions&nbsp;performed FLR and the completion Time Out&nbsp;value was configured to a range of less than&nbsp;16 msec.</li>\n\t<li>The server hangs and results in NMI when running&nbsp;&ldquo;mlxfwtop &ndash;d mt4103_pci_cr0&rdquo; while&nbsp;restarting the driver in parallel (from a different&nbsp;thread). In this case, the downstream&nbsp;bridge over the device reported completion&nbsp;timeout error.</li>\n\t<li>In flow_steering,&nbsp;BMC could not receive a ping over&nbsp;IPV6 after running bmc_reboot.</li>\n\t<li>While closing the&nbsp;HCA, the RX packet caused bad access to&nbsp;resources that did not exist, and consequently caused the QPCGW or the irisc to get stuck.</li>\n\t<li>The master SMLID&nbsp;and the LID was either 0 or&nbsp;0xFFFF when the port was neither active nor&nbsp;armed.</li>\n\t<li>ibdump could not capture&nbsp;all MADs packets.</li>\n\t<li>link did not&nbsp;go up after reboot.</li>\n\t<li>Fixed a rare issue that cause the PCIe&nbsp;configuration cycle that arrived during the&nbsp;time of sw_reset to generate 2 completions.</li>\n\t<li>Network Controller Sideband Interface (NC-SI) did not&nbsp;work when adding the disable_static_steering_ini field in the ini file, due to&nbsp;memory allocation issue for this field in the&nbsp;scratchpad.</li>\n</ul>\n\n<p><strong>Fixes in version 2.42.5056:</strong></p>\n\n<ul>\n\t<li>Fixed an issue that resulted in reading from invalid I/O address on handover from UEFI boot to OS boot, when a port was configured as InfiniBand on a VPI adapter device.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5000:</strong><br />\n&nbsp;&nbsp; &nbsp;764282-B21<br />\n&nbsp;&nbsp; &nbsp;764286-B21&nbsp;&nbsp;</p>\n\n<p><strong>Firmware for the following devices are updated to 2.42.5056:</strong><br />\n&nbsp;&nbsp; &nbsp;764283-B21<br />\n&nbsp;&nbsp;&nbsp;&nbsp;764284-B21</p>\n\n<p><strong>Firmware for the following device&nbsp;is&nbsp;updated to 2.42.5700:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;764285-B21</p>\n\n<p><strong>New features in firmware version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>Added support for the following features.\n\t<ul>\n\t\t<li>new TLV: CX3_GLOBAL_CONF to enable/disable timestamp on incoming packets through mlxconfig configuration.</li>\n\t\t<li>User MAC configuration.</li>\n\t\t<li>Automatically collecting mstdump before driver reset.</li>\n\t\t<li>A&nbsp;mechanism to detect DEAD_IRISC (plastic) from TPT (iron) and raise an assert.</li>\n\t\t<li>A new field is added to &quot;set port&quot; command which notifies the firmware what is the user_mtu size.</li>\n\t</ul>\n\t</li>\n\t<li>Improved the debug ability for command timeout cases.</li>\n</ul>\n\n<p><strong>New features and changes&nbsp;in firmware version 2.42.5700.</strong></p>\n\n<ul>\n\t<li>Modified the mlx_cmd_get_mlx_link_status command return value to return &quot;Link Type = Ethernet&quot; in Ethernet adapter cards.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Fixes in version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>PortRcvPkts counter was prevented from being cleared after&nbsp;resetting it.</li>\n\t<li>The system&nbsp;Timed Out on the configuration cycle of&nbsp;the Virtual Functions (VFs) when more than 10 Virtual Functions&nbsp;performed FLR and the completion Time Out&nbsp;value was configured to a range of less than&nbsp;16 msec.</li>\n\t<li>The server hangs and results in NMI when running&nbsp;&ldquo;mlxfwtop &ndash;d mt4103_pci_cr0&rdquo; while&nbsp;restarting the driver in parallel (from a different&nbsp;thread). In this case, the downstream&nbsp;bridge over the device reported completion&nbsp;timeout error.</li>\n\t<li>In flow_steering,&nbsp;BMC could not receive a ping over&nbsp;IPV6 after running bmc_reboot.</li>\n\t<li>While closing the&nbsp;HCA, the RX packet caused bad access to&nbsp;resources that did not exist, and consequently caused the QPCGW or the irisc to get stuck.</li>\n\t<li>The master SMLID&nbsp;and the LID was either 0 or&nbsp;0xFFFF when the port was neither active nor&nbsp;armed.</li>\n\t<li>ibdump could not capture&nbsp;all MADs packets.</li>\n\t<li>link did not&nbsp;go up after reboot.</li>\n\t<li>Fixed a rare issue that cause the PCIe&nbsp;configuration cycle that arrived during the&nbsp;time of sw_reset to generate 2 completions.</li>\n\t<li>Network Controller Sideband Interface (NC-SI) did not&nbsp;work when adding the disable_static_steering_ini field in the ini file, due to&nbsp;memory allocation issue for this field in the&nbsp;scratchpad.</li>\n</ul>\n\n<p><strong>Fixes in version 2.42.5056:</strong></p>\n\n<ul>\n\t<li>Fixed an issue that resulted in reading from invalid I/O address on handover from UEFI boot to OS boot, when a port was configured as InfiniBand on a VPI adapter device.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_VPI","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5700-764285-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F4","Version":"2.42.5700"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5056-764283-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F2","Version":"2.42.5056"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5056-764284-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F3","Version":"2.42.5056"},{"DeviceName":"HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5000-764286-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F5","Version":"2.42.5000"},{"DeviceName":"HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5000-764282-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F1","Version":"2.42.5000"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains utilities and binaries for upgrading HPE VPI (Ethernet and Infiniband mode of operation) device firmware on Linux x86_64 platform."},{"lang":"ja","x_late":"このパッケージは、Linux x86_64プラットフォーム上でHPE VPI（EthernetおよびInfinibandモードで動作）デバイスファームウェアをアップグレードするためのユーティリティおよびバイナリを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>InfiniBand Card Type</strong></td>\n\t\t\t<td><strong>Firmware&nbsp;Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+M Adapter (764282-B21)</td>\n\t\t\t<td>2.42.5000</td>\n\t\t\t<td>HP_1350110023</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+M Adapter (764283-B21)</td>\n\t\t\t<td>2.42.5056</td>\n\t\t\t<td>HP_1360110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+QSFP Adapter (764284-B21)</td>\n\t\t\t<td>2.42.5056</td>\n\t\t\t<td>HP_1370110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+FLR-QSFP Adapter (764285-B21)</td>\n\t\t\t<td>2.42.5700</td>\n\t\t\t<td>HP_1380110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+FLR-QSFP Adapter (764286-B21)</td>\n\t\t\t<td>2.42.5000</td>\n\t\t\t<td>HP_1390110023</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"2890672","datemodified":"2020-11-12T07:52:58","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/CP045906.xml","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/getmlnxinfo","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/nic_fw/fw-ConnectX3Pro-rel-2_42_5000-764282-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/nic_fw/fw-ConnectX3Pro-rel-2_42_5000-764286-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/nic_fw/fw-ConnectX3Pro-rel-2_42_5056-764283-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/nic_fw/fw-ConnectX3Pro-rel-2_42_5056-764284-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/nic_fw/fw-ConnectX3Pro-rel-2_42_5700-764285-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/nic_fw/mstflint","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045906.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045906.scexe"],"md5sum":"5c3c1937c3187c46524a9f5c237e963b","name":"firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1.x86_64.rpm","release":"2020-11-12T07:49:07","revision":"0","sha1sum":"d05404b3fa1e19acbcaeb33b2bef7b17802a0e52","size":"2MB","target_guids":["a6b1a447-382a-5a4f-15B3-1007103C22F4","a6b1a447-382a-5a4f-15B3-1007103C22F2","a6b1a447-382a-5a4f-15B3-1007103C22F3","a6b1a447-382a-5a4f-15B3-1007103C22F5","a6b1a447-382a-5a4f-15B3-1007103C22F1"],"type_of_change":"1","version":"1.0.12"}],"id":{"product":"d0d15d83c7a84846a84195d46ef502f4","version":"bd2c2b5bb3894999be9e6352b3ce9436"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>Updating firmware with rpm installed:</strong></p>\n\n<ul>\n\t<li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li>\n\t<li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li>\n\t<li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li>\n</ul>\n\n<p><strong>Updating firmware without installing rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li>\n\t<li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於執行 Linux x86_64 平台的 HPE Mellanox VPI (Ethernet 與 Infiniband 模式) 裝置的線上韌體升級公用程式 (Linux x86_64)"},{"lang":"en","x_late":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Mellanox VPI (Ethernet and Infiniband mode) devices on Linux x86_64 platform"},{"lang":"ko","x_late":"Linux x86_64 플랫폼의 HPE Mellanox VPI(이더넷 및 Infiniband 모드) 장치용 온라인 펌웨어 업그레이드 유틸리티(Linux x86_64)"},{"lang":"cn","x_late":"用于Linux x86_64平台上的HPE Mellanox VPI（Ethernet和Infiniband模式）设备的在线固件升级实用程序（Linux x86_64）"},{"lang":"ja","x_late":"オンラインファームウェアアップグレードユーティリティ (Linux x86_64) for HPE Mellanox VPI (EthernetおよびInfinibandモード)デバイス - Linux x86_64プラットフォーム"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-10-16T19:30:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5000:</strong><br />\n&nbsp;&nbsp; &nbsp;764282-B21<br />\n&nbsp;&nbsp; &nbsp;764286-B21&nbsp;&nbsp;</p>\n\n<p><strong>Firmware for the following devices are updated to 2.42.5056:</strong><br />\n&nbsp;&nbsp; &nbsp;764283-B21<br />\n&nbsp;&nbsp;&nbsp;&nbsp;764284-B21</p>\n\n<p><strong>Firmware for the following device&nbsp;is&nbsp;updated to 2.42.5700:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;764285-B21</p>\n\n<p><strong>New features in firmware version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>Added support for the following features.\n\t<ul>\n\t\t<li>new TLV: CX3_GLOBAL_CONF to enable/disable timestamp on incoming packets through mlxconfig configuration.</li>\n\t\t<li>User MAC configuration.</li>\n\t\t<li>Automatically collecting mstdump before driver reset.</li>\n\t\t<li>A&nbsp;mechanism to detect DEAD_IRISC (plastic) from TPT (iron) and raise an assert.</li>\n\t\t<li>A new field is added to &quot;set port&quot; command which notifies the firmware what is the user_mtu size.</li>\n\t</ul>\n\t</li>\n\t<li>Improved the debug ability for command timeout cases.</li>\n</ul>\n\n<p><strong>New features and changes&nbsp;in firmware version 2.42.5700.</strong></p>\n\n<ul>\n\t<li>Modified the mlx_cmd_get_mlx_link_status command return value to return &quot;Link Type = Ethernet&quot; in Ethernet adapter cards.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Fixes in version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>PortRcvPkts counter was prevented from being cleared after&nbsp;resetting it.</li>\n\t<li>The system&nbsp;Timed Out on the configuration cycle of&nbsp;the Virtual Functions (VFs) when more than 10 Virtual Functions&nbsp;performed FLR and the completion Time Out&nbsp;value was configured to a range of less than&nbsp;16 msec.</li>\n\t<li>The server hangs and results in NMI when running&nbsp;&ldquo;mlxfwtop &ndash;d mt4103_pci_cr0&rdquo; while&nbsp;restarting the driver in parallel (from a different&nbsp;thread). In this case, the downstream&nbsp;bridge over the device reported completion&nbsp;timeout error.</li>\n\t<li>In flow_steering,&nbsp;BMC could not receive a ping over&nbsp;IPV6 after running bmc_reboot.</li>\n\t<li>While closing the&nbsp;HCA, the RX packet caused bad access to&nbsp;resources that did not exist, and consequently caused the QPCGW or the irisc to get stuck.</li>\n\t<li>The master SMLID&nbsp;and the LID was either 0 or&nbsp;0xFFFF when the port was neither active nor&nbsp;armed.</li>\n\t<li>ibdump could not capture&nbsp;all MADs packets.</li>\n\t<li>link did not&nbsp;go up after reboot.</li>\n\t<li>Fixed a rare issue that cause the PCIe&nbsp;configuration cycle that arrived during the&nbsp;time of sw_reset to generate 2 completions.</li>\n\t<li>Network Controller Sideband Interface (NC-SI) did not&nbsp;work when adding the disable_static_steering_ini field in the ini file, due to&nbsp;memory allocation issue for this field in the&nbsp;scratchpad.</li>\n</ul>\n\n<p><strong>Fixes in version 2.42.5056:</strong></p>\n\n<ul>\n\t<li>Fixed an issue that resulted in reading from invalid I/O address on handover from UEFI boot to OS boot, when a port was configured as InfiniBand on a VPI adapter device.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5000:</strong><br />\n&nbsp;&nbsp; &nbsp;764282-B21<br />\n&nbsp;&nbsp; &nbsp;764286-B21&nbsp;&nbsp;</p>\n\n<p><strong>Firmware for the following devices are updated to 2.42.5056:</strong><br />\n&nbsp;&nbsp; &nbsp;764283-B21<br />\n&nbsp;&nbsp;&nbsp;&nbsp;764284-B21</p>\n\n<p><strong>Firmware for the following device&nbsp;is&nbsp;updated to 2.42.5700:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;764285-B21</p>\n\n<p><strong>New features in firmware version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>Added support for the following features.\n\t<ul>\n\t\t<li>new TLV: CX3_GLOBAL_CONF to enable/disable timestamp on incoming packets through mlxconfig configuration.</li>\n\t\t<li>User MAC configuration.</li>\n\t\t<li>Automatically collecting mstdump before driver reset.</li>\n\t\t<li>A&nbsp;mechanism to detect DEAD_IRISC (plastic) from TPT (iron) and raise an assert.</li>\n\t\t<li>A new field is added to &quot;set port&quot; command which notifies the firmware what is the user_mtu size.</li>\n\t</ul>\n\t</li>\n\t<li>Improved the debug ability for command timeout cases.</li>\n</ul>\n\n<p><strong>New features and changes&nbsp;in firmware version 2.42.5700.</strong></p>\n\n<ul>\n\t<li>Modified the mlx_cmd_get_mlx_link_status command return value to return &quot;Link Type = Ethernet&quot; in Ethernet adapter cards.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Fixes in version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>PortRcvPkts counter was prevented from being cleared after&nbsp;resetting it.</li>\n\t<li>The system&nbsp;Timed Out on the configuration cycle of&nbsp;the Virtual Functions (VFs) when more than 10 Virtual Functions&nbsp;performed FLR and the completion Time Out&nbsp;value was configured to a range of less than&nbsp;16 msec.</li>\n\t<li>The server hangs and results in NMI when running&nbsp;&ldquo;mlxfwtop &ndash;d mt4103_pci_cr0&rdquo; while&nbsp;restarting the driver in parallel (from a different&nbsp;thread). In this case, the downstream&nbsp;bridge over the device reported completion&nbsp;timeout error.</li>\n\t<li>In flow_steering,&nbsp;BMC could not receive a ping over&nbsp;IPV6 after running bmc_reboot.</li>\n\t<li>While closing the&nbsp;HCA, the RX packet caused bad access to&nbsp;resources that did not exist, and consequently caused the QPCGW or the irisc to get stuck.</li>\n\t<li>The master SMLID&nbsp;and the LID was either 0 or&nbsp;0xFFFF when the port was neither active nor&nbsp;armed.</li>\n\t<li>ibdump could not capture&nbsp;all MADs packets.</li>\n\t<li>link did not&nbsp;go up after reboot.</li>\n\t<li>Fixed a rare issue that cause the PCIe&nbsp;configuration cycle that arrived during the&nbsp;time of sw_reset to generate 2 completions.</li>\n\t<li>Network Controller Sideband Interface (NC-SI) did not&nbsp;work when adding the disable_static_steering_ini field in the ini file, due to&nbsp;memory allocation issue for this field in the&nbsp;scratchpad.</li>\n</ul>\n\n<p><strong>Fixes in version 2.42.5056:</strong></p>\n\n<ul>\n\t<li>Fixed an issue that resulted in reading from invalid I/O address on handover from UEFI boot to OS boot, when a port was configured as InfiniBand on a VPI adapter device.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_VPI","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for HPE Blade QLogic NX2 10/20 GbE Multifunction Adapters running under VMware vSphere 6.7."},{"lang":"ja","x_late":"この製品には、VMware vSphere 6.7上で動作するHPE Blade QLogic NX2 10/20 GbEマルチファンクションアダプター用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains the following drivers:</p>\n\n<ul>\n\t<li>qcnic, version 1.0.59.0</li>\n\t<li>qfle3i, version 1.1.5.0</li>\n\t<li>qfle3f, version 1.1.25.0</li>\n\t<li>qfle3, version 1.1.17.0</li>\n</ul>\n"}],"files":[{"bytes":"1400657","datemodified":"2021-08-12T04:38:32","file_list":["/cp047629.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip/index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip/metadata.zip","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip/vib20/qfle3f/QLC_bootbank_qfle3f_1.1.25.0-1OEM.670.0.0.8169922.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip/vib20/qfle3i/QLC_bootbank_qfle3i_1.1.5.0-1OEM.670.0.0.8169922.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip/vib20/qfle3/QLC_bootbank_qfle3_1.1.17.0-1OEM.670.0.0.8169922.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip/vib20/qcnic/QLC_bootbank_qcnic_1.0.59.0-1OEM.670.0.0.8169922.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip/metadata.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip/metadata.zip/vmware.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip/metadata.zip/vibs/qfle3f--2870239878310587039.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip/metadata.zip/vibs/qfle3i--6801888692139910757.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip/metadata.zip/vibs/qfle3--5362795065017542531.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip/metadata.zip/vibs/qcnic--558619672783143317.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip/metadata.zip/bulletins/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922.xml"],"md5sum":"df5a4e7646c5bacecb41c3d50cb0a5cc","name":"cp047629.zip","release":"2021-08-12T04:35:13","revision":"0","sha1sum":"5d76d4609869a2f51713f4816a8996a6afeea3eb","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecbba24fc7","20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","20a6e8e4-bf33-4c71-a6bf-d9eca261a1a0","20a6e8e4-bf33-4c71-a6bf-d9ec7339bbbe"],"type_of_change":"0","version":"2021.09.01","vib_list":[{"name":"qfle3f","version":"1.1.25.0-1OEM.670.0.0.8169922"},{"name":"qfle3i","version":"1.1.5.0-1OEM.670.0.0.8169922"},{"name":"qfle3","version":"1.1.17.0-1OEM.670.0.0.8169922"},{"name":"qcnic","version":"1.0.59.0-1OEM.670.0.0.8169922"}]}],"id":{"product":"86ed65a9ad3d4de69d4874b14dbe2a9a","version":"c520825cd81e46a08a99ad471673fc5e"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for VMware vSphere 6.7"},{"lang":"ja","x_late":"HPE Blade QLogic NX2 10/20 GbEマルチファンクションドライバー for VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"168E","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1933","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c22fa","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1917","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1916","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1933","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1916","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1917","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c22fa","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1933","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c22fa","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1916","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1917","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-03T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports VMware vShere 6.7 U3.<br />\nThis product has improved handling of complex flooding and race condition issues.</p>\n","latest_fixes_x_late":"<p>This product addresses a PSOD involving an encapsulated header.<br />\nThis product addresses a PSOD seen during traffic scheduling.<br />\nThis product corrects an incorrect MTU value displayed by the ESXCLI tool.<br />\nThis product addresses a PSOD issue seen during Storage vMotion operation.<br />\nThis product addresses PSODs seen during discovery timeout, transmit scheduling, and LUN reset scenarios.<br />\nThis product addresses a PSOD seen on systems operating in a complicated VLAN environment.<br />\nThis product addresses a PSOD seen during critical packet drop scenarios.</p>\n"},{"curr_enhancements_x_late":"<p>This product enhances PLOGI for the HPE XP7 Storage Array.</p>\n","curr_fixes_x_late":"<p>This product addresses a PSOD seen while collecting data dump.<br />\nThis product addessses a PSOD seen during uplink reset with failure conditions.<br />\nThis product addresses a PSOD seen during device state changes without IDLE state.<br />\nThis product addresses a PSOD seen during scheduling fabic login.<br />\nThis product addresses a PSOD issue to enhance immediately flush in work queue and unload/quiesce mechanisms.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"qcnic:1.0.59.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qfle3:1.1.17.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qfle3f:1.1.25.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qfle3i:1.1.5.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"LO0400KEFJQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-304f-3430-304b45464a51","Version":"HPK4"},{"DeviceName":"LO0800KEFJR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-304f-3830-304b45464a52","Version":"HPK4"},{"DeviceName":"LO1600KEFJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-314f-3630-304b45464a54","Version":"HPK4"},{"DeviceName":"LO2000KEFJU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-324f-3030-304b45464a55","Version":"HPK4"},{"DeviceName":"LT0800KEXVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-3054-3830-304b45585641","Version":"HPK4"},{"DeviceName":"LT1600KEXVB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-3154-3630-304b45585642","Version":"HPK4"},{"DeviceName":"LT2000KEXVC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-3254-3030-304b45585643","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: LO0400KEFJQ, LO0800KEFJR, LO1600KEFJT, LO2000KEFJU, LT0800KEXVA, LT1600KEXVB and LT2000KEXVC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;NVMe SSD&nbsp;Flash Component for Windows&nbsp;(x64) - &nbsp;LO0400KEFJQ, LO0800KEFJR, LO1600KEFJT, LO2000KEFJU, LT0800KEXVA, LT1600KEXVB&nbsp;and LT2000KEXVC Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"2877056","datemodified":"2021-07-25T12:36:48","file_list":["4IFDHPK4.rel","cp048428.xml","cpqsetup.exe","payload.json","setup.dll"],"md5sum":"31834d489466daadeab1b148d9101615","name":"cp048428.exe","release":"2021-07-25T12:29:14","revision":"0","sha1sum":"36948fb561e9728d3d5d74e1494d0ee114bd59a0","size":"2MB","target_guids":["002340a5-4c00-304f-3430-304b45464a51","002340a5-4c00-304f-3830-304b45464a52","002340a5-4c00-314f-3630-304b45464a54","002340a5-4c00-324f-3030-304b45464a55","002340a5-4c00-3054-3830-304b45585641","002340a5-4c00-3154-3630-304b45585642","002340a5-4c00-3254-3030-304b45585643"],"type_of_change":"1","version":"HPK4"}],"id":{"product":"8f00f37b744a48c992007d0537ca5fe1","version":"1709552d124d408fa390ababd0a7671f"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\<SPP root folder>\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"http://www.hpe.com/jp/servers/spp_dl\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリに配置します。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) - LO0400KEFJQ, LO0800KEFJR, LO1600KEFJT, LO2000KEFJU, LT0800KEXVA, LT1600KEXVB, and LT2000KEXVC Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - LO0400KEFJQ、LO0800KEFJR、LO1600KEFJT、LO2000KEFJU、LT0800KEXVA、LT1600KEXVB、およびLT2000KEXVCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"LT0800KEXVA","target_guid":"002340a5-4c00-3054-3830-304b45585641","type":"nvme"},{"id":"LT1600KEXVB","target_guid":"002340a5-4c00-3154-3630-304b45585642","type":"nvme"},{"id":"LT2000KEXVC","target_guid":"002340a5-4c00-3254-3030-304b45585643","type":"nvme"},{"id":"LO2000KEFJU","target_guid":"002340a5-4c00-324f-3030-304b45464a55","type":"nvme"},{"id":"LO0400KEFJQ","target_guid":"002340a5-4c00-304f-3430-304b45464a51","type":"nvme"},{"id":"LO0800KEFJR","target_guid":"002340a5-4c00-304f-3830-304b45464a52","type":"nvme"},{"id":"LO1600KEFJT","target_guid":"002340a5-4c00-314f-3630-304b45464a54","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-10T07:42:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for&nbsp;Microsoft Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"LO0400KEFJQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LO1600KEFJT","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LT2000KEXVC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LO0800KEFJR","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LT0800KEXVA","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LT1600KEXVB","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LO2000KEFJU","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300060","languages":[{"lang":"tw","x_late":"驅動程式 ─ 視訊"},{"lang":"en","x_late":"Driver - Video"},{"lang":"ko","x_late":"드라이버 - 비디오"},{"lang":"cn","x_late":"驱动程序 - 视频"},{"lang":"ja","x_late":"ドライバ - ビデオ"}]}],"description":[{"lang":"en","x_late":"This component provides advanced video support for the Matrox G200eH video controller."},{"lang":"ja","x_late":"このコンポーネントは、Matrox G200eHビデオ コントローラー対応の高度なビデオ機能を提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"cn","x_late":"服务器选项"},{"lang":"ja","x_late":"サーバ オプション"}]}],"documentation":[],"files":[{"bytes":"1604072","datemodified":"2019-07-19T14:20:34","file_list":["cp038691.xml","cpqsetup.exe","generic.dll","install.xml","Matrox.WddmUninstaller.exe","MxG2hDO.inf","mxg2hdo64.cat","MxG2hDO64.sys"],"md5sum":"a072ee5975b6a7bee9c041dbced9f0a0","name":"cp038691.exe","release":"2019-07-19T14:19:02","revision":"0","sha1sum":"662ad48d18afb2efd4ebf96f3b6285c89422240d","size":"1MB","target_guids":[],"type_of_change":"0","version":"9.15.1.224"}],"id":{"product":"d90597ae6e7441a698018da6a13176bc","version":"e5fc3b642cf5449d99c1cb8ba85bc66f"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<P>Place the Smart Component in a temporary directory, then double-click it to run.</P>\n<P>Select \"Install\" to start extracting to a temporary location on the hard drive.</P>\n<P>Click the \"Install\" button to perform the driver installation.</P>"},{"lang":"ja","x_late":"<P>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。</P>\n<P>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。</P>\n<P>インストールボタンをクリックしてドライバーインストールを実行します。</P>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"Matrox G200eH Video Controller Driver for Windows Server 2012 and Server 2012 R2"},{"lang":"ja","x_late":"Matrox G200eHビデオコントローラードライバー for Windows Server 2012および2012 R2"}],"prerequisites":{"required_diskspace":{"size_kb":"10000"},"supported_devices":[{"dev":"0533","subdev":"330E","subven":"103C","target_guid":"","type":"pci","ven":"102B"},{"dev":"0533","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"102B"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows 8.1 (64-bit)","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-09-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Improved video performance compared to the 9.15.1.174 release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Fix for random screen corruption when changing resolution that could occur with driver versions 9.15.1.184 and 9.15.1.218.</li>\n\t<li>Fix for a display freeze that could occur when running the Windows Display Diagnostics tool (dispdiag.exe).</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"}],"sw_keys":[{"name":"MxG2hDO64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000300JWFVB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SErD3.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57465642","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG000300JWFVB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;EG000300JWFVB&nbsp;Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"3037848","datemodified":"2021-07-24T08:40:29","file_list":["cp048433.xml","cpqsetup.exe","payload.json","setup.dll","T14SErD3.REL"],"md5sum":"7e43eb95e7b155c1a87bb1245e098103","name":"cp048433.exe","release":"2021-07-24T08:32:04","revision":"0","sha1sum":"18284972895eee16ddb3024a0a0f1a497f3cd339","size":"2MB","target_guids":["452340a5-3047-3030-3330-304a57465642"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"211fcef09ace432ba1e1c0cdad640eeb","version":"9f12f8888f2445babdd0b58c6d4b7fbc"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG000300JWFVB Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EG000300JWFVB ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG000300JWFVB","target_guid":"452340a5-3047-3030-3330-304a57465642","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-10T09:44:05","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>A low-probability, high severity corner case of sustained outer-diameter activity with emergency power off when heads are at the outer diameter prevented heads from parking/latching properly on a few drives in the field.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG000300JWFVB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWEZB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757455a42","Version":"HPGG"},{"DeviceName":"VK000480GWEZC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757455a43","Version":"HPGG"},{"DeviceName":"VK000960GWEZD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757455a44","Version":"HPGG"},{"DeviceName":"VK001920GWEZE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757455a45","Version":"HPGG"},{"DeviceName":"MK000240GWEZF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3234-304757455a46","Version":"HPGG"},{"DeviceName":"MK000480GWEZH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757455a48","Version":"HPGG"},{"DeviceName":"MK000960GWEZK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757455a4b","Version":"HPGG"},{"DeviceName":"MK001920GWHRU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304757485255","Version":"HPGG"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: VK000240GWEZB, VK000480GWEZC, VK000960GWEZD, VK001920GWEZE, MK000240GWEZF, MK000480GWEZH, MK000960GWEZK and MK001920GWHRU Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：VK000240GWEZB、VK000480GWEZC、VK000960GWEZD、VK001920GWEZE、MK000240GWEZF、MK000480GWEZH、MK000960GWEZK、およびMK001920GWHRUドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux - VK000240GWEZB, VK000480GWEZC, VK000960GWEZD, VK001920GWEZE, MK000240GWEZF, MK000480GWEZH, MK000960GWEZK&nbsp;and MK001920GWHRU Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGG<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGB<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPGB</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5039895","datemodified":"2021-07-23T08:49:21","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-3db7640485-HPGG-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-3db7640485-HPGG-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-3db7640485-HPGG-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3db7640485-HPGG-2.1/CP048187.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-3db7640485-HPGG-2.1/M5100SGG.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-3db7640485-HPGG-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3db7640485-HPGG-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-3db7640485-HPGG-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-3db7640485-HPGG-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048187.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048187.scexe"],"md5sum":"afc00e4a6dc17f94cca8080201086110","name":"firmware-hdd-3db7640485-HPGG-2.1.x86_64.rpm","release":"2021-07-23T08:37:10","revision":"0","sha1sum":"070b038a4585a8cd5ad69c1cbe6330d0bca485f4","size":"4MB","target_guids":["562340a5-304b-3030-3234-304757455a42","562340a5-304b-3030-3438-304757455a43","562340a5-304b-3030-3936-304757455a44","562340a5-304b-3130-3932-304757455a45","4d2340a5-304b-3030-3234-304757455a46","4d2340a5-304b-3030-3438-304757455a48","4d2340a5-304b-3030-3936-304757455a4b","4d2340a5-304b-3130-3932-304757485255"],"type_of_change":"1","version":"HPGG"}],"id":{"product":"8c0c47d5bf1446e88cb749de3c7fd2d0","version":"3a6cdd7eff9c4910858d764fbee5da8e"},"installation":{"command":"CP041319.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left: 30pt;\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（.rpm拡張子のついていないrpmファイル名）を実行します。</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p>\n\n<ul>\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>追加情報：</strong></p>\n\n<p style=\"margin-left: 30pt;\">ファームウェアrpmパッケージのインストール (rpm -ivh)は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を解凍するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン:</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK000240GWEZB, VK000480GWEZC, VK000960GWEZD, VK001920GWEZE, MK000240GWEZF, MK000480GWEZH, MK000960GWEZK and MK001920GWHRU Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VK000240GWEZB、VK000480GWEZC、VK000960GWEZD、VK001920GWEZE、MK000240GWEZF、MK000480GWEZH、MK000960GWEZK、およびMK001920GWHRUドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MK001920GWHRU","target_guid":"4d2340a5-304b-3130-3932-304757485255","type":"sata"},{"id":"VK001920GWEZE","target_guid":"562340a5-304b-3130-3932-304757455a45","type":"sata"},{"id":"MK000240GWEZF","target_guid":"4d2340a5-304b-3030-3234-304757455a46","type":"sata"},{"id":"VK000240GWEZB","target_guid":"562340a5-304b-3030-3234-304757455a42","type":"sata"},{"id":"MK000480GWEZH","target_guid":"4d2340a5-304b-3030-3438-304757455a48","type":"sata"},{"id":"VK000480GWEZC","target_guid":"562340a5-304b-3030-3438-304757455a43","type":"sata"},{"id":"MK000960GWEZK","target_guid":"4d2340a5-304b-3030-3936-304757455a4b","type":"sata"},{"id":"VK000960GWEZD","target_guid":"562340a5-304b-3030-3936-304757455a44","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T08:07:33","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Improvements to Product Quality and Reliability.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK001920GWHRU","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000240GWEZF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWEZH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWEZC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GWEZE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWEZD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWEZK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWEZB","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000JFDSL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRNSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a4644534c","Version":"HPD4"},{"DeviceName":"MB4000JFDSN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRNSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a4644534e","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB2000JFDSL and MB4000JFDSN"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： MB2000JFDSL and MB4000JFDSN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - &nbsp;MB2000JFDSL and MB4000JFDSN Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3027400","datemodified":"2021-07-25T14:04:14","file_list":["cp048589.xml","cpqsetup.exe","payload.json","setup.dll","TTMRNSD4.REL"],"md5sum":"5ec3f3d59dfbea3618961c68c0e356c2","name":"cp048589.exe","release":"2021-07-25T13:57:04","revision":"0","sha1sum":"ef97d07b63088a88a38af916e4d0f6b628ade467","size":"2MB","target_guids":["002340a5-4d00-3242-3030-304a4644534c","002340a5-4d00-3442-3030-304a4644534e"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"96868d9680c84d50b81011a5d4811094","version":"d1d24df06b6a4d60ae84889e3f6d1cca"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB2000JFDSL and MB4000JFDSN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB2000JFDSLおよびMB4000JFDSNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB2000JFDSL","target_guid":"002340a5-4d00-3242-3030-304a4644534c","type":"sas"},{"id":"MB4000JFDSN","target_guid":"002340a5-4d00-3442-3030-304a4644534e","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T09:28:04","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JFDSN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB2000JFDSL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZPLJ1T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK75H3Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3154-3648f52fd02c","Version":"EPK75H3Q"},{"DeviceName":"MZPLJ3T2HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK75H3Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3354-3248fdc50136","Version":"EPK75H3Q"},{"DeviceName":"MZPLJ6T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK75H3Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3654-3448bda98199","Version":"EPK75H3Q"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MZPLJ1T6HBJR-000H3, MZPLJ3T2HBJR-000H3 and MZPLJ6T4HALA-000H3"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MZPLJ1T6HBJR-000H3、MZPLJ3T2HBJR-000H3およびMZPLJ6T4HALA-000H3"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for&nbsp;VMware ESXi - MZPLJ1T6HBJR-000H3, MZPLJ3T2HBJR-000H3 and MZPLJ6T4HALA-000H3 Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;&nbsp;EPK75H3Q</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; EPK74H3Q</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; EPK74H3Q</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features :</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp; &nbsp; &nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Fixed False UECC issue at idle power mode.</li>\n\t<li>Old FW download Blocking (EPK70H3Q~EPK74H3Q).</li>\n\t<li>FW is changed off the option of TX data alignment for each lane.</li>\n\t<li>FW is changed to clear the interrupt after TLP Complete when PCIe config read operation.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL: <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us\" style=\"color: rgb(5, 99, 193); text-decoration: underline;\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us</a></li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>提供名：</strong><br />\n      オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - MZPLJ1T6HBJR-000H3、MZPLJ3T2HBJR-000H3、およびMZPLJ6T4HALA-000H3ドライブ<br />\n <br />\n<strong>リリースバージョンおよび/または日付:</strong><br />\n      EPK75H3Q</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>最新の推奨またはクリティカルバージョン：</strong><br />\n      EPK74H3Q</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>前のファームウェアバージョン：</strong><br />\n      EPK74H3Q</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ファームウェアの関連性:<br />\n      </strong>なし  </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>改善点/新しい機能：</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">      なし</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>修正された問題：</strong></p>\n\n<ul>\n\t<li>アイドル電源モードでの誤ったUECCの問題を修正しました。</li>\n\t<li>古いファームウェアダウンロードブロッキング（EPK70H3Q〜EPK74H3Q）。</li>\n\t<li>ファームウェアは、各レーンのTXデータアライメントのオプションから変更されます。</li>\n\t<li>PCIe構成の読み取り操作時に、TLP完了後に割り込みをクリアするようにファームウェアが変更されました。</li>\n\t<li>詳しくは、HPE Customer Bulletin: <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us\" style=\"color: rgb(5, 99, 193); text-decoration: underline;\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us</a>を参照してください。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>既知の問題点:<br />\n     </strong>なし</p>\n"}],"files":[{"bytes":"25278144","datemodified":"2021-08-27T07:37:28","file_list":["/CP048458_BUILD_3.data","/CP048458.vmexe","/CP048458.vmexe64","/CP048458.vmfile","/CP048458_VMw.zip","/CP048458.xml","/payload.json","/CP048458_VMw.zip/index.xml","/CP048458_VMw.zip/vendor-index.xml","/CP048458_VMw.zip/metadata.zip","/CP048458_VMw.zip/vib20/CP048458/HPE_bootbank_CP048458_EPK75H3Q.3-7.0.0.15843807.vib","/CP048458_VMw.zip/metadata.zip/vendor-index.xml","/CP048458_VMw.zip/metadata.zip/vmware.xml","/CP048458_VMw.zip/metadata.zip/vibs/CP048458--4454703523534727790.xml","/CP048458_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048458_EPK75H3Q.3-7.0.0.15843807.xml"],"md5sum":"0fa828aea7fc0cfdc89f974841aee5b6","name":"CP048458.zip","release":"2021-08-27T07:32:01","revision":"0","sha1sum":"031c0764f59a10ed655bbc83dac4c816d3514340","size":"24MB","target_guids":["4d2340a5-505a-4a4c-3154-3648f52fd02c","4d2340a5-505a-4a4c-3354-3248fdc50136","4d2340a5-505a-4a4c-3654-3448bda98199"],"type_of_change":"2","version":"EPK75H3Q","vib_list":[{"name":"CP048458","version":"EPK75H3Q.3-7.0.0.15843807"}]}],"id":{"product":"a1d749637b0b455e9a43d66fc6eed023","version":"c9c0061608f647d8b69e5c9c92a83833"},"installation":{"command":"CP042960.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi - MZPLJ1T6HBJR-000H3, MZPLJ3T2HBJR-000H3 and MZPLJ6T4HALA-000H3 Drives"},{"lang":"ja","x_late":"オンラインNVMeSSDフラッシュコンポーネントfor VMwareESXi - MZPLJ1T6HBJR-000H3、MZPLJ3T2HBJR-000H3、およびMZPLJ6T4HALA-000H3ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MZPLJ1T6HBJR-000H3","target_guid":"4d2340a5-505a-4a4c-3154-3648f52fd02c","type":"nvme"},{"id":"MZPLJ6T4HALA-000H3","target_guid":"4d2340a5-505a-4a4c-3654-3448bda98199","type":"nvme"},{"id":"MZPLJ3T2HBJR-000H3","target_guid":"4d2340a5-505a-4a4c-3354-3248fdc50136","type":"nvme"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T09:35:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Fixed False UECC issue at idle power mode.</li>\n\t<li>Old FW download Blocking (EPK70H3Q~EPK74H3Q).</li>\n\t<li>FW is changed off the option of TX data alignment for each lane.</li>\n\t<li>FW is changed to clear the interrupt after TLP Complete when PCIe config read operation.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL: <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us\" style=\"color: rgb(5, 99, 193); text-decoration: underline;\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us</a></li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Fixed False UECC issue at idle power mode.</li>\n\t<li>Old FW download Blocking (EPK70H3Q~EPK74H3Q).</li>\n\t<li>FW is changed off the option of TX data alignment for each lane.</li>\n\t<li>FW is changed to clear the interrupt after TLP Complete when PCIe config read operation.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MZPLJ6T4HALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZPLJ1T6HBJR-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZPLJ3T2HBJR-000H3","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]},{"key":"7800374","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"en","x_late":"This package enables auto-nvme connectivity support on Linux Server for HPE Emulex Host Bus Adapters"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"8784","datemodified":"2021-08-26T06:28:13","file_list":["./usr/lib/dracut/dracut.conf.d/70-nvmefc-autoconnect.conf","./usr/lib/systemd/system/nvmefc-boot-connections.service","./usr/lib/systemd/system/nvmefc-connect@.service","./usr/lib/udev/rules.d/70-nvmefc-autoconnect.rules","./usr/sbin/lpfc/nvmefc_boot_connections.sh","./usr/share/smartupdate/nvmefc-connect/component.xml"],"md5sum":"88bc6e063768a3f5273214780f5cb8fb","name":"nvmefc-connect-12.8.264.0-1.rhel7u8.noarch.rpm","release":"2021-08-26T06:16:24","revision":"0","sha1sum":"aa8dd8548a88cca8b46dbe6cf119f8e62b125a22","size":"8KB","target_guids":[],"type_of_change":"0","version":"12.8.264.0"},{"bytes":"8784","datemodified":"2021-08-26T06:24:06","file_list":["./usr/lib/dracut/dracut.conf.d/70-nvmefc-autoconnect.conf","./usr/lib/systemd/system/nvmefc-boot-connections.service","./usr/lib/systemd/system/nvmefc-connect@.service","./usr/lib/udev/rules.d/70-nvmefc-autoconnect.rules","./usr/sbin/lpfc/nvmefc_boot_connections.sh","./usr/share/smartupdate/nvmefc-connect/component.xml"],"md5sum":"70133216a8248780c3f6a3eab4e5784d","name":"nvmefc-connect-12.8.264.0-1.rhel7u9.noarch.rpm","release":"2021-08-26T06:16:24","revision":"0","sha1sum":"dfe0f3ecc97bbbd7c542804c5609527a78addb68","size":"8KB","target_guids":[],"type_of_change":"0","version":"12.8.264.0"}],"id":{"product":"0e2a232ab05049628712cf0a27f95dc5","version":"0c64b087c81443cc8f13df737fe97f37"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To install the elx-nvmefc-connect RPM use the following command:</p>\n\n<p>&nbsp;&nbsp; # rpm -ivh elx-nvmefc-connect-&lt;version&gt;.noarch.rpm</p>\n\n<p>To upgrade the elx-nvmefc-connect RPM use the following command:</p>\n\n<p>&nbsp;# rpm -Uvh elx-nvmefc-connect-&lt;version&gt;.noarch.rpm</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE NVMe Fibre Channel Enablement Kit for Emulex Host Bus Adapters for Linux  Server"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"F100","subven":"10DF","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T10:35:35","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to version 12.8.264.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"nvmefc-connect","sw_key_expectedpath":"software:rpm"},{"name":"nvmefc-connect","sw_key_expectedpath":"software:rpm"},{"name":"nvmefc-connect","sw_key_expectedpath":"software:rpm"},{"name":"nvmefc-connect","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWRTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLPeAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57525444","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB008000JWRTD"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB008000JWRTD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB008000JWRTD Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD1<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp;</strong> None</p>\n"}],"files":[{"bytes":"18520056","datemodified":"2021-08-30T20:29:14","file_list":["/CP048332_BUILD_2.data","/CP048332.vmexe","/CP048332.vmexe64","/CP048332.vmfile","/CP048332_VMw.zip","/CP048332.xml","/payload.json","/CP048332_VMw.zip/index.xml","/CP048332_VMw.zip/vendor-index.xml","/CP048332_VMw.zip/metadata.zip","/CP048332_VMw.zip/vib20/CP048332/HPE_bootbank_CP048332_HPD2.2-7.0.0.15843807.vib","/CP048332_VMw.zip/metadata.zip/vendor-index.xml","/CP048332_VMw.zip/metadata.zip/vmware.xml","/CP048332_VMw.zip/metadata.zip/vibs/CP048332-3419053399330638890.xml","/CP048332_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048332_HPD2.2-7.0.0.15843807.xml"],"md5sum":"dc0671bb2a404eb50f75a9ec5fc41af2","name":"CP048332.zip","release":"2021-08-30T20:24:06","revision":"0","sha1sum":"23f1a89122727b1c0788e0a308af57d5415ee87f","size":"17MB","target_guids":["4d2340a5-3042-3830-3030-304a57525444"],"type_of_change":"1","version":"HPD2","vib_list":[{"name":"CP048332","version":"HPD2.2-7.0.0.15843807"}]}],"id":{"product":"a9e8e46bd6de460ea736a9be4499f26a","version":"1ae91753efa442e5b2359d160fded862"},"installation":{"command":"CP041478.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB008000JWRTD Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB008000JWRTD ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB008000JWRTD","target_guid":"4d2340a5-3042-3830-3030-304a57525444","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-05T19:04:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000JWRTD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Blade QLogic NX2 10Gb and 20Gb Multifunction Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Blade QLogic NX2 10Gbおよび20GbマルチファンクションGigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"7314752","datemodified":"2021-07-21T19:45:56","file_list":["./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/bnx2.ko","./lib/modules/5.3.18-22-default/updates/bnx2fc.ko","./lib/modules/5.3.18-22-default/updates/bnx2i.ko","./lib/modules/5.3.18-22-default/updates/bnx2x.ko","./lib/modules/5.3.18-22-default/updates/cnic.ko","./usr/share/smartupdate/netxtreme2_bl-kmp-default/component.xml"],"md5sum":"0519bb9523dd61e447a822ec24bbfd9b","name":"netxtreme2_bl-kmp-default-7.14.80_k5.3.18_22-5.sles15sp2.x86_64.rpm","release":"2021-07-21T19:14:13","revision":"0","sha1sum":"27d6ec70230cbc52fb570bd6d33afe06569e6f8b","size":"6MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3da3feeb"],"type_of_change":"0","version":"7.14.80-5"},{"bytes":"7483237","datemodified":"2021-07-21T19:48:54","file_list":["./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/5.3.18-57-default","./lib/modules/5.3.18-57-default/updates","./lib/modules/5.3.18-57-default/updates/bnx2.ko","./lib/modules/5.3.18-57-default/updates/bnx2fc.ko","./lib/modules/5.3.18-57-default/updates/bnx2i.ko","./lib/modules/5.3.18-57-default/updates/bnx2x.ko","./lib/modules/5.3.18-57-default/updates/cnic.ko","./usr/share/smartupdate/netxtreme2_bl-kmp-default/component.xml"],"md5sum":"8e7a56fb6f647fd3e3cf249f1bb0da9a","name":"netxtreme2_bl-kmp-default-7.14.80_k5.3.18_57-5.sles15sp3.x86_64.rpm","release":"2021-07-21T19:14:13","revision":"0","sha1sum":"85ffbb95b1c9266500a2092d61c67ce1dd1c70be","size":"7MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3da3feeb"],"type_of_change":"0","version":"7.14.80-5"}],"id":{"product":"f76235dc1aee44f3804452ef8c8047d0","version":"7901fe6be5cd4faeb301af32dbd3635c"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE Blade QLogic NX2 10/20 GbEマルチファンクションドライバーfor SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"168E","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1933","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c22fa","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1917","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1916","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1933","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1916","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1917","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c22fa","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1933","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c22fa","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1916","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1917","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-09-03T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 15 SP2.</p>\n","latest_fixes_x_late":"<p>This product corrects an issue where the driver fails to load in NPAR mode when RoCE Data Center Quantized Congestion Notification (DCQCN) is enabled.<br />\nThis product addresses a system crash seen when unloading and reloading the RoCE driver only.<br />\nThis product addresses a system crash seen during multiple reboots of virtual machines using VFs and RDMA.<br />\nThis product addresses a system crash seen when injecting a fw_assert on a NIC PF.<br />\nThis product corrects an issue where a system fails to shutdown after reboots in iSCSI BFS.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports&nbsp;SUSE Linux Enterprise Server 15&nbsp;SP3.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"netxtreme2_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"netxtreme2_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"netxtreme2_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"netxtreme2_bl-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"HPE Smart Array controller driver component for VMware vSphere 6.5, for use with HPE Smart Update Manager."},{"lang":"ja","x_late":"HPE Smart Update Managerで使用するHPE Smartアレイコントローラードライバーコンポーネント for VMware vSphere 6.5。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"190821","datemodified":"2020-12-04T05:36:58","file_list":["/cp042874.xml","/VMW-ESX-6.5.0-nhpsa-65.0072.0.149-offline_bundle-17204132.zip","/VMW-ESX-6.5.0-nhpsa-65.0072.0.149-offline_bundle-17204132.zip/index.xml","/VMW-ESX-6.5.0-nhpsa-65.0072.0.149-offline_bundle-17204132.zip/vendor-index.xml","/VMW-ESX-6.5.0-nhpsa-65.0072.0.149-offline_bundle-17204132.zip/metadata.zip","/VMW-ESX-6.5.0-nhpsa-65.0072.0.149-offline_bundle-17204132.zip/vib20/nhpsa/Microsemi_bootbank_nhpsa_65.0072.0.149-1OEM.650.0.0.4598673.vib","/VMW-ESX-6.5.0-nhpsa-65.0072.0.149-offline_bundle-17204132.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.5.0-nhpsa-65.0072.0.149-offline_bundle-17204132.zip/metadata.zip/vmware.xml","/VMW-ESX-6.5.0-nhpsa-65.0072.0.149-offline_bundle-17204132.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-nhpsa-65.0072.0.149.xml","/VMW-ESX-6.5.0-nhpsa-65.0072.0.149-offline_bundle-17204132.zip/metadata.zip/vibs/nhpsa-2476583018873965280.xml"],"md5sum":"a32343ec19cd184991491b3890356395","name":"cp042874.zip","release":"2021-03-24T00:00:00","revision":"1","sha1sum":"2e8c2c29f166ed3a8db2e10f5f0232b3944f7e45","size":"186KB","target_guids":[],"type_of_change":"1","version":"2021.01.01","vib_list":[{"name":"nhpsa","version":"65.0072.0.149-1OEM.650.0.0.4598673"}]}],"id":{"product":"386613fae09d49a9a12412011f349ab9","version":"7fafbccf73f544149a7288af9db8da43"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant</strong></p>\n\n<p><strong>Remote Online: </strong></p>\n\n<ul>\n\t<li>&nbsp;Place the SPP on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\"><u>HPE USB Key Creator Utility</u></a><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">.</a></li>\n\t<li>&nbsp;Place the desired driver to be updated in the directory, /SPP20xxxxx/hp/swpackages on the USB key.</li>\n\t<li>&nbsp;Mount the USB key on a remote server running Windows or Linux</li>\n\t<li>&nbsp;CD /hp/swpackages and ./hpsum</li>\n\t<li>&nbsp;Select the next button</li>\n\t<li>&nbsp;Click Add Single Target</li>\n\t<li>&nbsp;Type the IP or DNS address of the ESXi host to be updated</li>\n\t<li>&nbsp;Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>&nbsp;Follow Smart Update Manager Steps and complete the update.</li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>&nbsp;Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>&nbsp;Use VMware VUM or esxcli commands to install the offline bundle.</li>\n\t<li>&nbsp;Refer to VMware documentation for information on VUM and the esxcli commands.</li>\n</ul>\n\n<p><br />\n&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、HPE Service Pack for ProLiantから以下の手順に従ってください</strong></p>\n\n<p><strong>リモートオンライン：</strong></p>\n\n<ul>\n\t<li> <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\"><u>HPE USB Key Creator Utility</u></a><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\">を使用して、SPPをUSBキーにコピーします。</a></li>\n\t<li> アップデートするドライバーをUSBキーの/SPP20xxxxx/hp/swpackagesディレクトリにコピーします。</li>\n\t<li> WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。</li>\n\t<li> CD /hp/swpackagesおよび./hpsum</li>\n\t<li> 次へボタンを選択します。</li>\n\t<li> シングルターゲットの追加をクリックします。</li>\n\t<li> 更新されるESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li> ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li> Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ul>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ul>\n\t<li> ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li>\n\t<li> オフラインバンドルをインストールするために、VMware VUMまたはesxcliコマンドを使用します。</li>\n\t<li> VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ul>\n\n<p><br/>\n </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE ProLiant Smart Array Controller Driver for VMware vSphere 6.5 (Driver Component)."},{"lang":"ja","x_late":"HPE ProLiant Smartアレイコントローラードライバー for VMware vSphere 6.5（ドライバーコンポーネント）"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"323c","subdev":"1928","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1922","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1923","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323C","subdev":"1929","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"323c","subdev":"1926","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3353","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1924","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1921","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3350","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3351","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3354","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3352","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323B","subdev":"3356","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3239","subdev":"21c5","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cb","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c1","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21be","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cc","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c3","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c0","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c2","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ca","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21BD","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21CD","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c6","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c8","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ce","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21bf","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c7","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-25T14:40:15","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>To add OS support for VMware ESXi 7.0 U1 P02</li>\n</ul>\n","latest_fixes_x_late":"<p>This release provides the following fixes:</p>\n\n<ul>\n\t<li>Fix failed TUR cmds hung in queue</li>\n\t<li>Fix internal cmd reservation broken</li>\n\t<li>Update for new version number scheme</li>\n\t<li>Fix verbose error messages on common innocuous errors<br />\n\t&nbsp;</li>\n\t<li>Failed logical volumes not being properly handled via offline state.</li>\n\t<li>Scsi sense and status returns are incorrect for some error conditions.</li>\n\t<li>Incorrect &#39;unavailable&#39; status seen during hot-plug recovery.</li>\n\t<li>Displayed target ID is incorrect in some driver log messages.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This release provides the following fixes:</p>\n\n<ul>\n\t<li>Fix failed TUR cmds hung in queue</li>\n\t<li>Fix internal cmd reservation broken</li>\n\t<li>Update for new version number scheme</li>\n\t<li>Fix verbose error messages on common innocuous errors<br />\n\t&nbsp;</li>\n\t<li>Failed logical volumes not being properly handled via offline state.</li>\n\t<li>Scsi sense and status returns are incorrect for some error conditions.</li>\n\t<li>Incorrect &#39;unavailable&#39; status seen during hot-plug recovery.</li>\n\t<li>Displayed target ID is incorrect in some driver log messages.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"J06","value":"HP ProLiant MicroServer Gen8"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P74","value":"HP ProLiant SL140s Gen8 Server (private)"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 SE Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"P83","value":"HP ProLiant SL210t Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"}],"sw_keys":[{"name":"nhpsa:65.0072.0.149-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains iSCSI drivers for the HPE Blade Emulex 10/20GbE Server Adapters running under SUSE Linux Enterprise Server 12."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12で動作するHPE Blade Emulex 10/20GbEサーバーアダプター用のiSCSIドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"892966","datemodified":"2021-03-08T18:01:40","file_list":["./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/be2iscsi","./lib/modules/4.12.14-120-default/updates/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/be2iscsi_bl-kmp-default/component.xml"],"md5sum":"078f24ffb9ccfbf0ae6a565c9847cb60","name":"be2iscsi_bl-kmp-default-12.0.1342.0_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-03-08T17:52:10","revision":"0","sha1sum":"b08a628ef5265116ee802c13d05745b33cc0005c","size":"872KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf6b47a9e"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"871242","datemodified":"2021-03-08T18:13:31","file_list":["./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/be2iscsi","./lib/modules/4.12.14-94.41-default/updates/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/be2iscsi_bl-kmp-default/component.xml"],"md5sum":"c286e9edc89302d9b790c48c568f0f93","name":"be2iscsi_bl-kmp-default-12.0.1342.0_k4.12.14_94.41-1.sles12sp4.x86_64.rpm","release":"2021-03-08T17:52:10","revision":"0","sha1sum":"3561023f17012264bb3f0f3feef4a604454ca46a","size":"850KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf6b47a9e"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"61d3db3934a9409ea2efff88ec08bbc6","version":"cab99dcef31246e79bbcb163a81e1b59"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE iSCSI Drivers for SUSE Linux Enterprise Server 12"},{"lang":"ja","x_late":"HPE Blade Emulex 10/20GbE iSCSIドライバー for SUSE Linux Enterprise Server 12"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0722","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>These drivers have been&nbsp;updated to maintain compatibility with the latest firmware.</p>\n","latest_fixes_x_late":"<p>These drivers have been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 12 SP5.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"be2iscsi_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2iscsi_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2iscsi_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2iscsi_bl-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5936808","datemodified":"2021-05-18T02:55:03","file_list":["P86_2.90_04_29_2021.signed.flash","SignedImageInstaller64.dll","cp047857.xml","cpqsetup.exe","cpqsysio64.sys"],"md5sum":"092424a983ac340d7dad02b2feaca179","name":"cp047857.exe","release":"2021-05-18T02:38:09","revision":"0","sha1sum":"47320885ddbd7a6808e2b8cfaff552a988d9ab75","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021"}],"id":{"product":"6f3dab1f723a42fab0fcd6264fd8e85f","version":"70dfb6019ddb457fa57a1f09c9baa5d6"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL120 Gen9 (P86) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant DL120 Gen9 (P86)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"edition":"fndtn","major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2 Foundation Edition","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-05T03:58:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"}],"sw_keys":[{"name":"P86","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001920KWVMT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1723b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304b57564d54","Version":"HPK3"},{"DeviceName":"VO003840KWVMU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1723b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304b57564d55","Version":"HPK3"},{"DeviceName":"VO007680KWVMV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1723b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304b57564d56","Version":"HPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VO001920KWVMT, VO003840KWVMU and VO007680KWVMV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for VMware ESXi -&nbsp;&nbsp;VO001920KWVMT, VO003840KWVMU, and VO007680KWVMV Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK2</p>\n\n<p><br />\n<strong>Previous Version of Firmware:&nbsp;</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"20958308","datemodified":"2021-08-27T06:33:46","file_list":["/CP048469_BUILD_3.data","/CP048469.vmexe","/CP048469.vmexe64","/CP048469.vmfile","/CP048469_VMw.zip","/CP048469.xml","/payload.json","/CP048469_VMw.zip/index.xml","/CP048469_VMw.zip/vendor-index.xml","/CP048469_VMw.zip/metadata.zip","/CP048469_VMw.zip/vib20/CP048469/HPE_bootbank_CP048469_HPK3.3-7.0.0.15843807.vib","/CP048469_VMw.zip/metadata.zip/vendor-index.xml","/CP048469_VMw.zip/metadata.zip/vmware.xml","/CP048469_VMw.zip/metadata.zip/vibs/CP048469-9035756745624418070.xml","/CP048469_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048469_HPK3.3-7.0.0.15843807.xml"],"md5sum":"116b305af12f2159f32b665211ac1dea","name":"CP048469.zip","release":"2021-08-27T06:28:24","revision":"0","sha1sum":"a02dcdad6a4af73797c173ae9353323c5cf52a56","size":"19MB","target_guids":["562340a5-304f-3130-3932-304b57564d54","562340a5-304f-3330-3834-304b57564d55","562340a5-304f-3730-3638-304b57564d56"],"type_of_change":"1","version":"HPK3","vib_list":[{"name":"CP048469","version":"HPK3.3-7.0.0.15843807"}]}],"id":{"product":"994a54e899fb4be5bf05bb0bf86539b6","version":"2162b782fbaf48fe97dc6857f785f7db"},"installation":{"command":"CP041138.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi  - VO001920KWVMT, VO003840KWVMU, and VO007680KWVMV Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi (x64) - VO001920KWVMT、VO003840KWVMU、およびVO007680KWVMVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VO007680KWVMV","target_guid":"562340a5-304f-3730-3638-304b57564d56","type":"nvme"},{"id":"VO003840KWVMU","target_guid":"562340a5-304f-3330-3834-304b57564d55","type":"nvme"},{"id":"VO001920KWVMT","target_guid":"562340a5-304f-3130-3932-304b57564d54","type":"nvme"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T14:01:27","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Fixed SSD weargauge report error issue.</li>\n\t<li>Fixed Assign FWState as TR_DONE_ERR at the correct location.</li>\n\t<li>Prepare proper response data for Get Message Type Supported MCTP Command.</li>\n\t<li>Added code to preserve current feature values cross live firmware update.</li>\n\t<li>Allocate 4 bytes instead of 2 bytes for parameter code.</li>\n\t<li>Changed the value for NLB equal to NSize -1.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO007680KWVMV","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO003840KWVMU","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO001920KWVMT","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5971832","datemodified":"2021-05-18T04:33:52","file_list":["SignedImageInstaller64.dll","U20_2.90_04_29_2021.signed.flash","cp047836.xml","cpqsetup.exe","cpqsysio64.sys"],"md5sum":"8cc1c99f6cfaa666310ab320e43bc0bf","name":"cp047836.exe","release":"2021-05-18T04:16:07","revision":"0","sha1sum":"e10fe5eebca74b8d38b26f85df75c6b1073cbdd5","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021"}],"id":{"product":"749b691cbdee45b1901a105f2f1d7a48","version":"99ec7313dafb47ccbfa4d7dd61534440"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.<br />\n&nbsp;</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br />\n </p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL160 Gen9/DL180 Gen9 (U20) Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-05T03:26:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"}],"sw_keys":[{"name":"U20","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG0600JEMCV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3630-304a454d4356","Version":"HPD6"},{"DeviceName":"EG1200JEMDA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3230-304a454d4441","Version":"HPD6"},{"DeviceName":"EG0300JFCKA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3330-304a46434b41","Version":"HPD6"},{"DeviceName":"EG0900JFCKB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3930-304a46434b42","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG0300JFCKA, EG0600JEMCV, EG0900JFCKB, and EG1200JEMDA"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 EG0300JFCKA、EG0600JEMCV、EG0900JFCKB、およびEG1200JEMDA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG0300JFCKA, EG0600JEMCV, EG0900JFCKB&nbsp;and EG1200JEMDA Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"5537739","datemodified":"2021-07-23T08:29:57","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-ac3fda26eb-HPD6-9.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac3fda26eb-HPD6-9.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac3fda26eb-HPD6-9.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac3fda26eb-HPD6-9.1/CP048077.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac3fda26eb-HPD6-9.1/STHBTND6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac3fda26eb-HPD6-9.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac3fda26eb-HPD6-9.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac3fda26eb-HPD6-9.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac3fda26eb-HPD6-9.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048077.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048077.scexe"],"md5sum":"8b4a8535e73bfda1f7c7500e98842e48","name":"firmware-hdd-ac3fda26eb-HPD6-9.1.x86_64.rpm","release":"2021-07-23T08:16:14","revision":"0","sha1sum":"5a86b346b2e2ddacc25f446434e5f802a3d35ba2","size":"5MB","target_guids":["002340a5-4500-3047-3630-304a454d4356","002340a5-4500-3147-3230-304a454d4441","002340a5-4500-3047-3330-304a46434b41","002340a5-4500-3047-3930-304a46434b42"],"type_of_change":"1","version":"HPD6"}],"id":{"product":"b52adb44d0e04f40a015897db8ad0e5d","version":"92a41defd1ea44e09417c7049c8e9be0"},"installation":{"command":"CP040272.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EG0300JFCKA, EG0600JEMCV, EG0900JFCKB and EG1200JEMDA Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - EG0300JFCKA、EG0600JEMCV、EG0900JFCKB、およびEG1200JEMDAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EG1200JEMDA","target_guid":"002340a5-4500-3147-3230-304a454d4441","type":"sas"},{"id":"EG0300JFCKA","target_guid":"002340a5-4500-3047-3330-304a46434b41","type":"sas"},{"id":"EG0600JEMCV","target_guid":"002340a5-4500-3047-3630-304a454d4356","type":"sas"},{"id":"EG0900JFCKB","target_guid":"002340a5-4500-3047-3930-304a46434b42","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T10:47:19","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG1200JEMDA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0600JEMCV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0900JFCKB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0300JFCKA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900217","languages":[{"lang":"fr","x_late":"Micrologiciel - Infrastructure Blade"},{"lang":"en","x_late":"Firmware - Blade Infrastructure"},{"lang":"cn","x_late":"固件 - 刀片式架构"},{"lang":"tw","x_late":"韌體 ─ 刀鋒型基礎架構"},{"lang":"de","x_late":"Firmware - Blade-Infrastruktur"},{"lang":"ko","x_late":"펌웨어 - 블레이드 인프라"},{"lang":"it","x_late":"Firmware - Infrastruttura Blade"},{"lang":"ja","x_late":"ファームウェア - ブレード インフラストラクチャ"},{"lang":"es","x_late":"Firmware - Infraestructura Blade"}]}],"description":[{"lang":"tw","x_late":"此元件包含適用於 HPE BladeSystem c-Class Virtual Connect 模組的韌體映像。此韌體提供 HPE BladeSystem c-Class Virtual Connect 模組的管理功能。此元件及其韌體可用於下列情況： 1) 搭配 BladeSystem 線上韌體套件中找到的 Smart Update Manager (智慧型更新管理器) 一起使用時，此元件可以用於部署韌體至 HPE BladeSystem c-Class Virtual Connect 模組；及 2) 從此元件解壓縮的韌體可使用 Virtual Connect Support Utility 部署至 HPE BladeSystem c-Class Virtual Connect 模組。"},{"lang":"en","x_late":"This component contains the firmware image for HPE BladeSystem c-Class Virtual Connect modules. This firmware provides management capabilities for the HPE BladeSystem c-Class Virtual Connect modules. This component and its firmware can be used in the following scenarios: 1) in conjunction with the Smart Update Manager found in the BladeSystem Online Firmware Bundle, the component can be used to deploy the firmware to the HPE BladeSystem c-Class Virtual Connect modules, and 2) firmware extracted from the component can be deployed using the Virtual Connect Support Utility for the HPE BladeSystem c-Class Virtual Connect modules."},{"lang":"ko","x_late":"이 구성 요소에는 HPE 블레이드시스템 c-클래스 가상 연결 모듈용 펌웨어 이미지가 포함되어 있습니다. 이 펌웨어는 HPE 블레이드시스템 c-클래스 가상 연결 모듈에 대한 관리 기능을 제공합니다. 해당 구성요소와 펌웨어는 다음과 같은 상황에서 사용할 수 있습니다. 1) 구성요소는 BladeSystem Online Firmware Bundle에서 확인된 Smart Update Manager와 함께 사용되어 HPE BladeSystem c-Class 가상 연결 모듈로 펌웨어를 배포할 수 있고, 2) HP BladeSystem c-Class 가상 연결 모듈용 가상 연결 지원 유틸리티를 통해 구성요소에서 추출된 펌웨어를 배포할 수 있습니다."},{"lang":"cn","x_late":"该组件可为 HPE BladeSystem c-Class Virtual Connect 模块提供固件镜像。该固件可为 HPE BladeSystem c-Class Virtual Connect 模块提供管理功能。该组件及其固件适用于以下情形： 1) 与在 HP BladeSystem 在线固件包上找到的HP智能升级管理器（Smart Update Manager）配合使用，此组件可用于将固件部署到 HPE C 系列刀片式系统虚拟连接（HP BladeSystem c-Class Virtual Connect）模块；2) 可通过适用于 HPE C 系列刀片式系统虚拟连接模块的虚拟连接支持实用程序（Virtual Connect Support Utility）部署从此组件中提取的固件。"},{"lang":"ja","x_late":"このコンポーネントには、HPE BladeSystem c-Class Virtual Connectモジュールのファームウェアイメージが含まれています。このファームウェアは、HPE BladeSystem c-Class Virtual Connectモジュールの管理機能を提供します。このコンポーネントおよびファームウェアは、以下のような場合に使用してください。1) HPE BladeSystem  c-Class Virtual Connectモジュールにファームウェアをインストールするために、Firmware Maintenance CD上あるいはHPE BladeSystem Online Firmware Bundle内にあるHPE Smart Update Managerと共同でコンポーネントを使用する 。および2) コンポーネントから展開したファームウェアをHPE BladeSystem c-Class Virtual ConnectモジュールのVirtual Connectサポートユーティリティを使用してインストールする。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[{"lang":"en","x_late":"<p>The 4.85&nbsp;version of HPE Virtual Connect Release Notes can be found in the following URL:&nbsp;<a href=\"http://www.hpe.com/info/vc/manuals\">http://www.hpe.com/info/vc/manuals</a></p>\n"}],"files":[{"bytes":"257255528","datemodified":"2020-07-20T02:59:57","file_list":["Entry.bsh","HpsumCli.exe","PackageDesc.xml","cp043332.xml","cp_data.xml","vcfwall485.bin"],"md5sum":"ac1a8acba5c6cd1a98afe0631175fa88","name":"cp043332.exe","release":"2020-07-20T02:44:05","revision":"0","sha1sum":"a058bbcd7e479bf87711be8a579659f09f81a315","size":"245MB","target_guids":[],"type_of_change":"1","version":"4.85"}],"id":{"product":"2720830f9ed94ee48b3be0778488e00f","version":"2d9971b9341e4bd8914f8b99847679ea"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":1500,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>This component and its firmware can be used in the following scenarios:</p>\n\n<ol>\n\t<li>\n\t<p>In conjunction with the Smart Update Manager found on the SPP, the component can be used to deploy the firmware to the HPE BladeSystem c-Class Virtual Connect module.</p>\n\t</li>\n\t<li>\n\t<p>Firmware extracted from the component can be deployed using the Virtual Connect Support Utility for the HPE BladeSystem c-Class Virtual Connect modules.</p>\n\t</li>\n</ol>\n\n<p><strong>Installation Notes for using the component with Smart Update Manager and SPP</strong></p>\n\n<ol>\n\t<li>Obtain the latest version of <a href=\"http://www.hpe.com/info/spp/download\">SPP</a>.</li>\n\t<li>Extract the contents of the SPP ISO, locate the directory, /usb, and run the hpusbkey.exe file.</li>\n\t<li>Place the SPP on a USB key using the USB Key Utility</li>\n\t<li>Place this version of the Virtual Connect firmware component in the directory, /hp/swpackages on the USB key.</li>\n\t<li>Place the USB key in a system which is on the same&nbsp;network as the HPE BladeSystem c-Class Virtual Connect module to be updated.</li>\n\t<li>Run &ldquo;launch_hpsum.bat/launch_hpsum.sh&rdquo; on the SPP from the USB key to launch the Smart Update Manager.</li>\n\t<li>Follow the GUI to install the firmware on the Virtual Connect module.</li>\n</ol>\n\n<p><strong>Installation Notes for using the firmware extracted from the component</strong></p>\n\n<ol>\n\t<li>\n\t<p>Extract the firmware binary out of the component.</p>\n\t</li>\n\t<li>\n\t<p>Place the firmware image file onto a system on the same network as the HPE BladeSystem c-Class Virtual Connect module.</p>\n\t</li>\n\t<li>\n\t<p>Start the Virtual Connect Support Utility and deploy the firmware.</p>\n\t</li>\n</ol>\n\n<p>HPE requires using the HPE BladeSystem c-Class Virtual Connect Support Utility version 1.15.0&nbsp;(or higher)&nbsp;to install the HPE VC FlexFabric-20/40 F8 version 4.85, HPE VC Flex-10/10D version&nbsp;4.85,&nbsp;HPE VC FlexFabric 10Gb/24-port version 4.85, HPE VC 8Gb 24-Port FC version&nbsp;4.20, HPE VC 16Gb 24-Port FC version 4.20,&nbsp;and HPE VC 8Gb 20-Port FC version 2.25&nbsp;firmware. Please read the HPE BladeSystem c-Class Virtual Connect Support Utility&nbsp;release notes.<br />\n<br />\nPlease be advised of a serious issue that could cause network outage when upgrading directly from VC 2.xx release version to VC 4.85&nbsp;release in Multi-Enclosure environment. Please upgrade from VC 2.xx to VC 3.70 or VC 4.10 first and then upgrade from VC 3.70 or VC 4.10 to VC 4.50 &nbsp;and then upgrade from VC 4.50 to VC 4.85&nbsp;in a Multi-Enclosure setup.</p>\n\n<p>To update HPE&nbsp;VC 8Gb 24-Port FC module(s) from Virtual Connect firmware 4.31 or lower to Virtual Connect 4.85&nbsp;or higher, these module(s) must first be updated with either Virtual Connect firmware version 4.4x or version 4.50 (Recommended version is 4.50) before they can be updated with Virtual Connect 4.85&nbsp;or higher.</p>\n\n<p>The USB Key Utility is used to copy the SPP onto a portable USB key storage device.&nbsp; Please note that the latest version (v2.0.0.0)&nbsp;of the utility is now 64-bit only.&nbsp; If the 32-bit application is needed, please use version 1.8, however, this version will not work on an ISO image greater than 4GB.</p>\n\n<p><strong>Note: Please read the Important note section of the Release Notes for firmware upgrade instructions.</strong></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"HPE BladeSystem c-Class Virtual Connect 韌體，乙太網路加上 8Gb 20 埠及 8/16Gb 24 埠 FC Edition 元件 (適用於 Windows)"},{"lang":"en","x_late":"HPE BladeSystem c-Class Virtual Connect Firmware, Ethernet plus 8Gb 20-port and 8/16Gb 24-port FC Edition  Component for Windows"},{"lang":"ko","x_late":"Windows용 HPE BladeSystem c-Class Virtual Connect 펌웨어, Ethernet plus 8Gb 20포트 및 8/16Gb 24포트 FC Edition 구성 요소"},{"lang":"cn","x_late":"HPE BladeSystem c-Class 虚拟连接固件，适用于 Windows 的 Ethernet plus 8Gb 20 端口和 8/16Gb 24端口 FC Edition 组件"},{"lang":"ja","x_late":"HPE BladeSystem c-Class Virtual Connectファームウェア、Ethernet plus 8Gb 20ポートおよび8/16 Gb 24ポートFC Editionコンポーネントfor Windows"}],"prerequisites":{"required_diskspace":{"size_kb":"60000"},"supported_devices":[{"id":"466482-B21","target_guid":"","type":"other"},{"id":"572018-B21","target_guid":"","type":"other"},{"id":"539535-B21","target_guid":"","type":"other"},{"id":"638526-B21","target_guid":"","type":"other"},{"id":"691367-B21","target_guid":"","type":"other"},{"id":"751465-B21","target_guid":"","type":"other"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-04-03T10:39:16","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>The list of enhancements in 4.80&nbsp;version can be found in the HPE Virtual Connect Release Notes at URL<strong>:&nbsp;</strong><a href=\"http://www.hpe.com/info/vc/manuals\">http://www.hpe.com/info/vc/manuals</a></p>\n","latest_fixes_x_late":"<p>The list of issues resolved in 4.80&nbsp;version can be found in the HPE Virtual Connect Release Notes at&nbsp;URL<strong>:&nbsp;</strong><a href=\"http://www.hpe.com/info/vc/manuals\">http://www.hpe.com/info/vc/manuals</a></p>\n"},{"curr_enhancements_x_late":"<p>The list of enhancements in 4.85&nbsp;version can be found in the HPE Virtual Connect Release Notes at URL<strong>:&nbsp;</strong><a href=\"http://www.hpe.com/info/vc/manuals\">http://www.hpe.com/info/vc/manuals</a></p>\n","curr_fixes_x_late":"<p>The list of issues resolved in 4.85&nbsp;version can be found in the HPE Virtual Connect Release Notes at&nbsp;URL<strong>:&nbsp;</strong><a href=\"http://www.hpe.com/info/vc/manuals\">http://www.hpe.com/info/vc/manuals</a></p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"BL860ci2","value":"HP Integrity BL860c i2 Server Blade"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"A19","value":"HP ProLiant BL465c G7 Server"},{"key":"I27","value":"HP ProLiant BL460c G7 Server"},{"key":"I28","value":"HP ProLiant BL490c G7 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I25","value":"HP ProLiant BL680c G7 Server"},{"key":"I25","value":"HP ProLiant BL620c G7 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"BL860ci4","value":"HP Integrity BL860c i4 Server Blade"},{"key":"BL870ci4","value":"HP Integrity BL870c i4 Server Blade"},{"key":"BL890ci4","value":"HP Integrity BL890c i4 Server Blade"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"BL870ci2","value":"HP Integrity BL870c i2 Server Blade"},{"key":"BL890ci2","value":"HP Integrity BL890c i2 Server Blade"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A20","value":"HP ProLiant BL685c G7 Server"},{"key":"I29","value":"HP ProLiant BL2x220c G7 Server"}],"sw_keys":[{"name":"vc8gb","sw_key_expectedpath":"firmware:vc8gb"},{"name":"vceth","sw_key_expectedpath":"firmware:vceth"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE QLogic NX2 10Gb and 20Gb Multifunction Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 12 x86_64."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12 x86_64で動作するHPE QLogic NX2 10Gbおよび20GbマルチファンクションGigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"6397440","datemodified":"2021-07-26T07:33:58","file_list":["./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/bnx2.ko","./lib/modules/4.12.14-120-default/updates/bnx2fc.ko","./lib/modules/4.12.14-120-default/updates/bnx2i.ko","./lib/modules/4.12.14-120-default/updates/bnx2x.ko","./lib/modules/4.12.14-120-default/updates/cnic.ko","./usr/share/smartupdate/netxtreme2-kmp-default/component.xml"],"md5sum":"2841a1798c2073de2fefa384a1939438","name":"netxtreme2-kmp-default-7.14.80_k4.12.14_120-6.sles12sp5.x86_64.rpm","release":"2021-07-26T07:20:09","revision":"0","sha1sum":"136449fa27d57782063016ac3f241bfc5f5015a3","size":"6MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec41a44bbb"],"type_of_change":"0","version":"7.14.80-6"}],"id":{"product":"4cbf7b1f2fb64da880e8ed0ed8c83095","version":"7e464c1db93843babc7ea62af4956338"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>Download README for any additional installation instructions.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE QLogic NX2 10/20 GbE Multifunction Drivers for SUSE Linux Enterprise Server 12 x86_64"},{"lang":"ja","x_late":"HPE QLogic NX2 10/20 GbEマルチファンクションドライバーfor SUSE Linux Enterprise Server 12 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"168E","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c339d","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c18d3","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1930","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c193a","type":"pci","ven":"14E4"},{"dev":"16A1","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a1159000ec","type":"pci","ven":"1077"},{"dev":"16AF","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c339d","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c18d3","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c193a","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1930","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1931","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"3382","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c3382","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c339d","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c193a","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1930","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16ad159000ec","type":"pci","ven":"1077"},{"dev":"16A4","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a4159000ec","type":"pci","ven":"1077"},{"dev":"16AE","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1931","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16af15908148","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ae15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-168e15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1931","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue obtain Medium Dependent Interface(MDI) and Medium Dependent Interface Crossover (MDIX) information when execution ethtool tools</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>TBD</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"netxtreme2-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 546FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-full-rel-2_42_5044-779799-B21_Ax-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C8020","Version":"2.42.5044"},{"DeviceName":"HPE Ethernet 10Gb 2-port 546SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-full-rel-2_42_5044-779793-B21_0A-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C801F","Version":"2.42.5044"},{"DeviceName":"HPE Ethernet 100Gb 1-port 842QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_31_1014-874253-B21_Ax-UEFI-14.24.13-FlexBoot-3.6.403.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900246","Version":"16.31.1014"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640 FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_31_1200-817749-B21_Ax-UEFI-14.24.13-FlexBoot-3.6.403.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D3","Version":"14.31.1200"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_31_1200-817753-B21_Ax-UEFI-14.24.13-FlexBoot-3.6.403.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D4","Version":"14.31.1200"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Mellanox Ethernet only adapter firmware on ESXi 6.5"},{"lang":"ja","x_late":"このパッケージは、ESXi 6.5上でHPE Mellanox Ethernetアダプター専用のファームウェアをアップグレードするためのユーティリティとバイナリを含みます"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 546SFP+ Adapter (779793-B21)</td>\n\t\t\t<td>2.42.5044</td>\n\t\t\t<td>HP_1200111023</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 546FLR-SFP+ Adapter (779799-B21)</td>\n\t\t\t<td>2.42.5044</td>\n\t\t\t<td>HP_2240110004</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)</td>\n\t\t\t<td>14.31.1200</td>\n\t\t\t<td>HP_2690110034</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</td>\n\t\t\t<td>14.31.1200</td>\n\t\t\t<td>HP_2420110034</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter&nbsp;(874253-B21)</td>\n\t\t\t<td>16.31.1014</td>\n\t\t\t<td>HPE0000000014</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"28495825","datemodified":"2021-09-14T03:21:33","file_list":["/CP046583.vmexe","/CP046583.vmfile","/CP046583.xml","/CP046583_VMw.zip","/payload.json","/README.txt","/CP046583_VMw.zip/index.xml","/CP046583_VMw.zip/vendor-index.xml","/CP046583_VMw.zip/metadata.zip","/CP046583_VMw.zip/vib20/CP046583/HPE_bootbank_CP046583_1.0.1-6.5.0.4240417.vib","/CP046583_VMw.zip/metadata.zip/vendor-index.xml","/CP046583_VMw.zip/metadata.zip/vmware.xml","/CP046583_VMw.zip/metadata.zip/bulletins/Smart-Component-CP046583_1.0.1-6.5.0.4240417.xml","/CP046583_VMw.zip/metadata.zip/vibs/CP046583-7175730236529770760.xml"],"md5sum":"30f18643440bae93ea938b280b2a61c9","name":"CP046583.zip","release":"2021-09-14T12:14:43","revision":"0","sha1sum":"4ec866a570e8a960b54d0af970a70e186ed73b5b","size":"27MB","target_guids":["a6b1a447-382a-5a4f-15B3-1007103C8020","a6b1a447-382a-5a4f-15B3-1007103C801F","a6b1a447-382a-5a4f-15B3-101715900246","a6b1a447-382a-5a4f-15B3-1015159000D3","a6b1a447-382a-5a4f-15B3-1015159000D4"],"type_of_change":"1","version":"1.0.10","vib_list":[{"name":"CP046583","version":"1.0.1-6.5.0.4240417"}]}],"id":{"product":"80d81c90aa4043f99c110cbf04419c83","version":"11bfe3a846464dde92a1b8460b30db49"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Offline: &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p>\n\n<p>Remote Online, if the component is supported by SUM but is not yet part of an SPP:<br />\n&nbsp; &nbsp; Download the appropriate SPP<br />\n&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />\n&nbsp; &nbsp; Run SUM<br />\n&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />\n&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />\n&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />\n&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />\n&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />\n&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at: <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p>\n\n<p>Note: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p>\n\n<p>To use HPE Insight Control for vCenter: &nbsp;<br />\n&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />\n&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p>\n\n<p>To update firmware from VMware ESXi operating system on target server: &nbsp;<br />\n&nbsp; &nbsp; Enable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Login as root. (You must be root in order to apply the update) &nbsp;<br />\n&nbsp; &nbsp; Place the Smart Component in a temporary directory<br />\n&nbsp; &nbsp; Check if the nmst module is loaded already: vmkload_mod -l | grep nmst<br />\n&nbsp; &nbsp; If module is not loaded, use the command to load the module: vmkload_mod nmst<br />\n&nbsp; &nbsp; From the same directory, execute the Smart Component. For example: unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe<br />\n&nbsp; &nbsp; Follow the directions given by the Smart Component.<br />\n&nbsp; &nbsp; Logout.<br />\n&nbsp; &nbsp; Disable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Reboot your system, if required, for the firmware update to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (ESXi 6.5) for HPE Mellanox Ethernet only adapters"},{"lang":"ja","x_late":"HPE Mellanox Ethernetアダプター専用のオンラインファームウェアアップグレードユーティリティ(ESXi 6.5)"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_devices":[{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-18T07:10:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5044 :</strong></p>\n\n<p>&nbsp; &nbsp;779799-B21 (HPE Ethernet 10G 2-port 546FLR-SFP+ Adapter)<br />\n&nbsp; &nbsp;779793-B21 (HPE Ethernet 10G 2-port 546SFP+ Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.31.1200:</strong></p>\n\n<p>&nbsp; &nbsp;817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</p>\n\n<p>&nbsp;&nbsp;&nbsp;817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following device is updated to 16.29.1016:</strong></p>\n\n<p>&nbsp; &nbsp;874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</p>\n\n<p><strong>New Features and Changes included in version 16.31.1200:</strong></p>\n\n<ul>\n\t<li>Added a new NVconfig per Port for a specific Finisar module. This new NVconfig&nbsp;sets the port to work in AN mode and sets the module to No Data Management Engine (DME). This change&nbsp;does not affect the speed logic, only the forward error correction (FEC) logic (FEC override). <strong>Note:</strong>&nbsp;If the port does not&nbsp;come up, switch to Force mode.&nbsp;</li>\n</ul>\n\n<p><strong>New features and changes included &nbsp;in version 16.29.1016:</strong></p>\n\n<ul>\n\t<li>An option to allow applications to build their own QoS tree over the NIC hierarchy by connecting QPs to responder/requestor Queue Groups.</li>\n\t<li>&quot;InfiniBand&quot; properties set to the Network Device Function Redfish object.</li>\n\t<li>HW support for Flow Metering to utilize Advanced Steering Operation (ASO).&nbsp;HW Flow Meter allows higher scale, more accuracy, and better performance compare to the FW Flow Metering.</li>\n\t<li>Trust level for VFs. Once the VF is trusted, it will get a set of trusted capabilities.</li>\n\t<li>2 new Mini CQE formats: Responder Mini CQE With Flow Tag Layout Responder Mini CQE With l3_l4_info Layout</li>\n\t<li>UCX can now enable AR by exposing Out-Of-Ordering bitmask per SL with &quot;ooo_per_sl&quot; field in the HCA_VPORT context. It can be also queried by running the QUERY_HCA_VPORT_CONTEXT&nbsp;command.</li>\n\t<li>Steering DP hash flow groups.</li>\n\t<li>A new counter per vPort that counts the number of packets that reached the Ethernet RQ but cannot fit into the WQE due to their large size. Additionally, we added the option to control if such packet will cause &ldquo;CQE with Error&rdquo; or &ldquo;CQE_MOCK&rdquo;.</li>\n\t<li>PCIe Rx modifications to prevent the adapter cards from disappearing from the system.</li>\n\t<li>ignore_flow_level is now enabled by the TRUST LEVEL access registry.&nbsp;</li>\n\t<li>cq_overrun counter. The counter represents the number of times CQs enter an error state due to overflow that occur when the device tries to post a CQE into a full CQ buffer.</li>\n\t<li>[Beta]&nbsp;Enabled the capability to allow Virtual Functions to send Pause Frames packets.</li>\n\t<li>Enabled 10/25GbE auto-sensing with 3rd party when using 10/25GbE optical cables.</li>\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Fixes&nbsp;included in&nbsp; firmware version 2.42.5044 :</strong></p>\n\n<ul>\n\t<li>An issue that prevented the firmware from detecting a link_down event thus preventing the IB bond interface from going to a failover mode.</li>\n</ul>\n\n<p><strong>Fixes included&nbsp;in firmware version 14.29.1016:</strong></p>\n\n<ul>\n\t<li>Changed the default value of DCQCN&#39;s (Data center- Quantized Congestion Notification) &nbsp;NP parameter min_time_between_cnps to 4 on all devices to support larger scalability of cluster.</li>\n\t<li>An issue that caused&nbsp;packets to drop due to header size issues and/or failing checks. The issue was caused due to a Linux issue that caused&nbsp;VFs to set the wrong header size value in wqe_inline_header_mode input.</li>\n\t<li>When MKEY_BY_NAME was&nbsp;enabled by NVCONFIG and a large number of VFs were configured, VM restart (VF/PF FLR) will take longer than when MKEY_BY_NAME is disabled.</li>\n\t<li>On rare cases, a fatal error related to errors from the PCI transport layer might be reported during FLR.</li>\n\t<li>&nbsp;An issue that caused&nbsp;the device to go to dead IRISC as one of the firmware semaphores could not be released&nbsp;when a speed change or port state change was triggered.&nbsp;</li>\n</ul>\n\n<p><strong>No fixes are included in firmware version 14.31.1200.</strong></p>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5044 :</strong></p>\n\n<p>&nbsp; &nbsp;779799-B21 (HPE Ethernet 10G 2-port 546FLR-SFP+ Adapter)<br />\n&nbsp; &nbsp;779793-B21 (HPE Ethernet 10G 2-port 546SFP+ Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.31.1200:</strong></p>\n\n<p>&nbsp; &nbsp;817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.31.1200:</strong><br />\n&nbsp; &nbsp;817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following device is updated to 16.31.1014:</strong></p>\n\n<p>&nbsp; &nbsp;874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</p>\n\n<p><br />\n<strong>New features and changes in version 14.31.1200:</strong></p>\n\n<ul>\n\t<li>NVconfig per Port for a Specific Finisar Module: Added a new NVconfig per Port for a specific Finisar module. This new NVconfig sets the port to work in AN mode and sets the module to No DME. This change does not affect the speed logic, only the FEC logic (FEC override).<br />\n\t<strong>Note:</strong>&nbsp;If the port does not go up, switch to Force mode.&nbsp;</li>\n</ul>\n\n<p><strong>New features and changes in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>NIC scheduling feature support has been disabled for non-privileged functions.</li>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>Added support for Enabling/Disabling NIC and RDMA (port/partition) via the UEFI HII system settings.<br />\n\t<strong>Note:</strong>&nbsp;Values set in this option only take effect when is Ethernet mode.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Asymmetrical MSIX Configuration:&nbsp;This feature allows the device to be configured with a different number of MSIX<br />\n\tvectors per physical PCI functions.<br />\n\tTo use this feature, please follow these steps:\n\t<ul>\n\t\t<li>​​​​Clear NUM_PF_MSIX_VALID to disable global symmetrical MSIX configuration.</li>\n\t\t<li>Set PF_NUM_PF_MSIX_VALID to enable asymmetrical per Physical Function MSIX configuration.</li>\n\t\t<li>Configure PF_NUM_PF_MSIX per physical PCI function.</li>\n\t</ul>\n\t</li>\n\t<li>Support for RDMA partitioning and RDMA counters in IB mode.</li>\n\t<li>A new bit (&quot;data_in_order&quot;) was added to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.<br />\n\tPages are returned by the driver to the kernel without issuing the MANAGE_PAGES commands to the firmare.</li>\n\t<li>Enabled UID 0 to create resources with UMEM (User Memory).</li>\n\t<li>Receiving and sending native IB packets from/to the software (including all headers) via raw IBL2 QPs.</li>\n\t<li>RX RDMA NIC flow table on an IB port. Now the software can steer native IB packets to raw IB receive queues according to the DLID and<br />\n\tthe DQPN.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Fixes&nbsp;included in&nbsp; firmware version 2.42.5044 :</strong></p>\n\n<ul>\n\t<li>An issue that prevented the firmware from detecting a link_down event thus preventing the IB bond interface from going to a failover mode.</li>\n</ul>\n\n<p><strong>The following issues have been fixed in version 14.31.1200:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n</ul>\n\n<p style=\"margin-left:40px\"><strong>Additional Fixes included in version 14.31.1200:</strong></p>\n\n<ul>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n</ul>\n\n<p><strong>The following issues have been fixed in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>An assert that was caused when trying to open 1024 functions on the device and the maximum number of functions was 1023.</li>\n\t<li>Occasional performance issues related to RC QPs using E2E-credits (not connected to SRQ and doing send/receive traffic) when the ROCE_ACCL tx_window was enabled.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>A rare issue that caused RX pipe to hang.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>An issue that caused the TX queue to get into an unresponsive state when the VF rate limiter was set.</li>\n</ul>\n\n<p style=\"margin-left:40px\"><strong>Additional Fixes included in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>Disabled the CNP counter &ldquo;rp_cnp_ignored &quot; (triggered by OOS (out-of-sequence)) when all ports are IB.</li>\n\t<li>Fixed the TMP421 sensor temperature reporting.</li>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 System"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"","value":"HPE ProLiant SL4500 Chassis"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_NIC","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH0300JDXBA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SXD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3330-304a44584241","Version":"HPD5"},{"DeviceName":"EH0450JDXBB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SXD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3435-304a44584242","Version":"HPD5"},{"DeviceName":"EH0600JDXBC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SXD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3630-304a44584243","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EH0300JDXBA, EH0450JDXBB and EH0600JDXBC"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EH0300JDXBA、EH0450JDXBB、およびEH0600JDXBC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EH0300JDXBA, EH0450JDXBB&nbsp;and EH0600JDXBC Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"15994262","datemodified":"2021-08-30T06:36:08","file_list":["/CP048291_BUILD_2.data","/CP048291.vmexe","/CP048291.vmexe64","/CP048291.vmfile","/CP048291_VMw.zip","/CP048291.xml","/payload.json","/CP048291_VMw.zip/index.xml","/CP048291_VMw.zip/vendor-index.xml","/CP048291_VMw.zip/metadata.zip","/CP048291_VMw.zip/vib20/CP048291/HPE_bootbank_CP048291_HPD5.2-7.0.0.15843807.vib","/CP048291_VMw.zip/metadata.zip/vendor-index.xml","/CP048291_VMw.zip/metadata.zip/vmware.xml","/CP048291_VMw.zip/metadata.zip/vibs/CP048291-4490760307014992427.xml","/CP048291_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048291_HPD5.2-7.0.0.15843807.xml"],"md5sum":"7d2c5417d430635c414b0ff823ca34ce","name":"CP048291.zip","release":"2021-08-30T06:31:33","revision":"0","sha1sum":"13dd9db1478f31f1d4a0b29f4abe599669c6352f","size":"15MB","target_guids":["002340a5-4500-3048-3330-304a44584241","002340a5-4500-3048-3435-304a44584242","002340a5-4500-3048-3630-304a44584243"],"type_of_change":"1","version":"HPD5","vib_list":[{"name":"CP048291","version":"HPD5.2-7.0.0.15843807"}]}],"id":{"product":"d39d0611a5e74799a9f08e5f5809ddba","version":"cb04a674a70c4c16a19cc21714c93e9c"},"installation":{"command":"CP039429.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EH0300JDXBA, EH0450JDXBB and EH0600JDXBC Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EH0300JDXBA、EH0450JDXBB、およびEH0600JDXBCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EH0300JDXBA","target_guid":"002340a5-4500-3048-3330-304a44584241","type":"sas"},{"id":"EH0450JDXBB","target_guid":"002340a5-4500-3048-3435-304a44584242","type":"sas"},{"id":"EH0600JDXBC","target_guid":"002340a5-4500-3048-3630-304a44584243","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-03T05:56:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH0450JDXBB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0300JDXBA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0600JDXBC","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000800JXBEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a58424556","Version":"HPD1"},{"DeviceName":"MO001600JXBFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a58424650","Version":"HPD1"},{"DeviceName":"MO003200JXBFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a58424651","Version":"HPD1"},{"DeviceName":"MO006400JXBFR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a58424652","Version":"HPD1"},{"DeviceName":"MO000960JXBFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3936-304a58424641","Version":"HPD1"},{"DeviceName":"MO001920JXBFT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a58424654","Version":"HPD1"},{"DeviceName":"MO003840JXBFU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3834-304a58424655","Version":"HPD1"},{"DeviceName":"MO007680JXBGA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3730-3638-304a58424741","Version":"HPD1"},{"DeviceName":"MO015360JXBFV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3531-3336-304a58424656","Version":"HPD1"},{"DeviceName":"EO000400JXBEU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304a58424555","Version":"HPD1"},{"DeviceName":"EO000800JXBFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304a5842464c","Version":"HPD1"},{"DeviceName":"EO001600JXBFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-304a5842464e","Version":"HPD1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MO000800JXBEV、MO001600JXBFP、MO003200JXBFQ、MO006400JXBFR、MO000960JXBFA、MO001920JXBFT、MO003840JXBFU、MO007680JXBGA、MO015360JXBFV、EO000400JXBEU、EO000800JXBFL およびEO001600JXBFN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3415640","datemodified":"2021-07-27T12:57:02","file_list":["cp049152.xml","cpqsetup.exe","HBCQSssseFD1.rel","payload.json","setup.dll"],"md5sum":"b12a35879d4b777703d2426667b1e077","name":"cp049152.exe","release":"2021-07-27T12:49:05","revision":"0","sha1sum":"38cff43342780a5ae6f2e21a31eb19b318f6bc6c","size":"3MB","target_guids":["4d2340a5-304f-3030-3830-304a58424556","4d2340a5-304f-3130-3630-304a58424650","4d2340a5-304f-3330-3230-304a58424651","4d2340a5-304f-3630-3430-304a58424652","4d2340a5-304f-3030-3936-304a58424641","4d2340a5-304f-3130-3932-304a58424654","4d2340a5-304f-3330-3834-304a58424655","4d2340a5-304f-3730-3638-304a58424741","4d2340a5-304f-3531-3336-304a58424656","452340a5-304f-3030-3430-304a58424555","452340a5-304f-3030-3830-304a5842464c","452340a5-304f-3130-3630-304a5842464e"],"type_of_change":"1","version":"HPD1"}],"id":{"product":"f0e80dda550e422981f666fd854cb6f6","version":"9ce35e34acf8492b9991619b738de2d9"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows（x64）- MO000800JXBEV、MO001600JXBFP、MO003200JXBFQ、MO006400JXBFR、MO000960JXBFA、MO001920JXBFT、MO003840JXBFU、MO007680JXBGA、MO015360JXBFV、EO000400JXBEU、EO000800JXBFLおよびEO001600JXBFNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MO000800JXBEV","target_guid":"4d2340a5-304f-3030-3830-304a58424556","type":"sas"},{"id":"MO001600JXBFP","target_guid":"4d2340a5-304f-3130-3630-304a58424650","type":"sas"},{"id":"MO003200JXBFQ","target_guid":"4d2340a5-304f-3330-3230-304a58424651","type":"sas"},{"id":"MO006400JXBFR","target_guid":"4d2340a5-304f-3630-3430-304a58424652","type":"sas"},{"id":"MO000960JXBFA","target_guid":"4d2340a5-304f-3030-3936-304a58424641","type":"sas"},{"id":"MO001920JXBFT","target_guid":"4d2340a5-304f-3130-3932-304a58424654","type":"sas"},{"id":"MO003840JXBFU","target_guid":"4d2340a5-304f-3330-3834-304a58424655","type":"sas"},{"id":"MO007680JXBGA","target_guid":"4d2340a5-304f-3730-3638-304a58424741","type":"sas"},{"id":"MO015360JXBFV","target_guid":"4d2340a5-304f-3531-3336-304a58424656","type":"sas"},{"id":"EO000400JXBEU","target_guid":"452340a5-304f-3030-3430-304a58424555","type":"sas"},{"id":"EO000800JXBFL","target_guid":"452340a5-304f-3030-3830-304a5842464c","type":"sas"},{"id":"EO001600JXBFN","target_guid":"452340a5-304f-3130-3630-304a5842464e","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-27T12:43:30","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;. Support for second source PMIC from IDT.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MO001920JXBFT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000400JXBEU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800JXBEV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003840JXBFU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200JXBFQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO015360JXBFV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO001600JXBFN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600JXBFP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000960JXBFA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO007680JXBGA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000800JXBFL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO006400JXBFR","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWSRQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757535251","Version":"HPG4"},{"DeviceName":"VK000480GWSRR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757535252","Version":"HPG4"},{"DeviceName":"VK000960GWSRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757535254","Version":"HPG4"},{"DeviceName":"VK001920GWSRU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757535255","Version":"HPG4"},{"DeviceName":"VK003840GWSRV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304757535256","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000240GWSRQ, VK000480GWSRR, VK000960GWSRT, VK001920GWSRU and VK003840GWSRV Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000240GWSRQ、VK000480GWSRR、VK000960GWSRT、VK001920GWSRU、およびVK003840GWSRVドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VK000240GWSRQ, VK000480GWSRR, VK000960GWSRT, VK001920GWSRU and&nbsp;VK003840GWSRV &nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None.</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"6335245","datemodified":"2021-07-23T09:25:41","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-db687966b4-HPG4-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-db687966b4-HPG4-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-db687966b4-HPG4-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-db687966b4-HPG4-3.1/CP048205.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-db687966b4-HPG4-3.1/GPM883G4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-db687966b4-HPG4-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-db687966b4-HPG4-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-db687966b4-HPG4-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-db687966b4-HPG4-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048205.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048205.scexe"],"md5sum":"1fd48dcae67a21ed230cf81374d98fb1","name":"firmware-hdd-db687966b4-HPG4-3.1.x86_64.rpm","release":"2021-07-23T09:12:16","revision":"0","sha1sum":"dd09a87fcb700216ac3facc16d12a7e0d6f95f5c","size":"6MB","target_guids":["562340a5-304b-3030-3234-304757535251","562340a5-304b-3030-3438-304757535252","562340a5-304b-3030-3936-304757535254","562340a5-304b-3130-3932-304757535255","562340a5-304b-3330-3834-304757535256"],"type_of_change":"1","version":"HPG4"}],"id":{"product":"225a3736a3d645ae82a85050bf27993e","version":"28b280620dec45c6bb98dee8614c15ad"},"installation":{"command":"CP043494.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（.rpm拡張子の付いていないrpmファイル名）を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p>\n\n<ul>\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>追加情報：</strong></p>\n\n<p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を解凍するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:</strong><br/>\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK000240GWSRQ, VK000480GWSRR, VK000960GWSRT, VK001920GWSRU and VK003840GWSRV  Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VK000240GWSRQ、VK000480GWSRR、VK000960GWSRT、VK001920GWSRU、およびVK003840GWSRVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VK003840GWSRV","target_guid":"562340a5-304b-3330-3834-304757535256","type":"sata"},{"id":"VK001920GWSRU","target_guid":"562340a5-304b-3130-3932-304757535255","type":"sata"},{"id":"VK000960GWSRT","target_guid":"562340a5-304b-3030-3936-304757535254","type":"sata"},{"id":"VK000480GWSRR","target_guid":"562340a5-304b-3030-3438-304757535252","type":"sata"},{"id":"VK000240GWSRQ","target_guid":"562340a5-304b-3030-3234-304757535251","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T11:30:36","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK001920GWSRU","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GWSRV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWSRQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWSRT","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWSRR","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000JEFNC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRASD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a45464e43","Version":"HPD9"},{"DeviceName":"MB6000JEFND","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRASD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a45464e44","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB4000JEFNC and MB6000JEFND"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MB4000JEFNCおよびMB6000JEFND"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB4000JEFNC and MB6000JEFND Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp; Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3654592","datemodified":"2021-07-25T14:55:08","file_list":["cp048607.xml","cpqsetup.exe","payload.json","setup.dll","SMKRASD9.rel"],"md5sum":"22efc5a0ba137b2051d33343fc339195","name":"cp048607.exe","release":"2021-07-25T14:47:05","revision":"0","sha1sum":"d9a999c46d30f9463f09dd7f25c2149f15085830","size":"3MB","target_guids":["002340a5-4d00-3442-3030-304a45464e43","002340a5-4d00-3642-3030-304a45464e44"],"type_of_change":"1","version":"HPD9"}],"id":{"product":"fc0a79d6952d41d4919e3578b5303d5a","version":"b42613000fc445edba7ba7d4fd02d469"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB4000JEFNC and MB6000JEFND Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB4000JEFNCおよびMB6000JEFNDドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB4000JEFNC","target_guid":"002340a5-4d00-3442-3030-304a45464e43","type":"sas"},{"id":"MB6000JEFND","target_guid":"002340a5-4d00-3642-3030-304a45464e44","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T10:37:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JEFNC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB6000JEFND","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000GFEMH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNFG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304746454d48","Version":"HPG6"},{"DeviceName":"MB4000GFEMK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNFG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304746454d4b","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB2000GFEMH and MB4000GFEMK"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB2000GFEMHおよびMB4000GFEMK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB2000GFEMH and MB4000GFEMK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp; &nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.&nbsp; This issue was found during supplier ongoing reliability testing.</p>\n\t</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n\t<li>\n\t<p>Online firmware update fails when drives are connected behind AHCI controller.</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"17509833","datemodified":"2021-08-26T18:53:26","file_list":["/CP048346_BUILD_2.data","/CP048346.vmexe","/CP048346.vmexe64","/CP048346.vmfile","/CP048346_VMw.zip","/CP048346.xml","/payload.json","/CP048346_VMw.zip/index.xml","/CP048346_VMw.zip/vendor-index.xml","/CP048346_VMw.zip/metadata.zip","/CP048346_VMw.zip/vib20/CP048346/HPE_bootbank_CP048346_HPG6.2-7.0.0.15843807.vib","/CP048346_VMw.zip/metadata.zip/vendor-index.xml","/CP048346_VMw.zip/metadata.zip/vmware.xml","/CP048346_VMw.zip/metadata.zip/vibs/CP048346-7396468137369311180.xml","/CP048346_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048346_HPG6.2-7.0.0.15843807.xml"],"md5sum":"5dc4e43e961589935f9c614a73ec6cf0","name":"CP048346.zip","release":"2021-08-26T18:48:08","revision":"0","sha1sum":"c9d964185cd2e9fe501a6c7a8a35cda492fe341c","size":"16MB","target_guids":["002340a5-4d00-3242-3030-304746454d48","002340a5-4d00-3442-3030-304746454d4b"],"type_of_change":"2","version":"HPG6","vib_list":[{"name":"CP048346","version":"HPG6.2-7.0.0.15843807"}]}],"id":{"product":"63f9bb70bcb94f2c9378d569ebb38b7e","version":"c02204a5edf24ba38be0ca01d58f5c51"},"installation":{"command":"CP040642.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB2000GFEMH and MB4000GFEMK Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB2000GFEMHおよびMB4000GFEMKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB4000GFEMK","target_guid":"002340a5-4d00-3442-3030-304746454d4b","type":"sata"},{"id":"MB2000GFEMH","target_guid":"002340a5-4d00-3242-3030-304746454d48","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-06T18:39:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was found during supplier ongoing reliability testing.</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n\t<li>\n\t<p>Online firmware update fails when drives are connected behind AHCI controller.</p>\n\t</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was found during supplier ongoing reliability testing.</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n\t<li>\n\t<p>Online firmware update fails when drives are connected behind AHCI controller.</p>\n\t</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000GFEMK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB2000GFEMH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK007680GWSXN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M52008G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-30475753584e","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: VK007680GWSXN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;VK007680GWSXN&nbsp;Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG2</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG2<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"3138192","datemodified":"2021-07-25T19:13:05","file_list":["cp048640.xml","cpqsetup.exe","M52008G3.rel","payload.json","setup.dll"],"md5sum":"54785e4430c47577e939ebbaa48a29a6","name":"cp048640.exe","release":"2021-07-25T19:06:04","revision":"0","sha1sum":"c34ecc2f032549e1da25bad7aa5cce9459a04cb5","size":"2MB","target_guids":["562340a5-304b-3730-3638-30475753584e"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"32232f7880984b91885a4743fd2f886d","version":"2116acedd87944c8917df65bc1b131e9"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK007680GWSXN  Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - VK007680GWSXNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VK007680GWSXN","target_guid":"562340a5-304b-3730-3638-30475753584e","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T17:15:46","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Improved Product Quality and Reliability. Changed Cap Charge Timeout to 14 seconds from 4 seconds to provide additional time for cap charge in marginal power environment.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK007680GWSXN","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWJNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEn0HPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e48","Version":"HPD4"},{"DeviceName":"EG001200JWJNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEn0HPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e4b","Version":"HPD4"},{"DeviceName":"EG000300JWSJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEn0HPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57534a50","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EG000300JWSJP, EG000600JWJNH and EG001200JWJNK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp; </strong>None</p>\n"}],"files":[{"bytes":"16182089","datemodified":"2021-08-27T19:05:34","file_list":["/CP049144_BUILD_3.data","/CP049144.vmexe","/CP049144.vmexe64","/CP049144.vmfile","/CP049144_VMw.zip","/CP049144.xml","/payload.json","/CP049144_VMw.zip/index.xml","/CP049144_VMw.zip/vendor-index.xml","/CP049144_VMw.zip/metadata.zip","/CP049144_VMw.zip/vib20/CP049144/HPE_bootbank_CP049144_HPD4.3-7.0.0.15843807.vib","/CP049144_VMw.zip/metadata.zip/vendor-index.xml","/CP049144_VMw.zip/metadata.zip/vmware.xml","/CP049144_VMw.zip/metadata.zip/vibs/CP049144--6291453488852411283.xml","/CP049144_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049144_HPD4.3-7.0.0.15843807.xml"],"md5sum":"3dac168f1cc2a3b1420f7c5a093a058b","name":"CP049144.zip","release":"2021-08-27T19:00:06","revision":"0","sha1sum":"9b63db59efb97fef50225273cf45138e344fb6de","size":"15MB","target_guids":["452340a5-3047-3030-3630-304a574a4e48","452340a5-3047-3130-3230-304a574a4e4b","452340a5-3047-3030-3330-304a57534a50"],"type_of_change":"1","version":"HPD4","vib_list":[{"name":"CP049144","version":"HPD4.3-7.0.0.15843807"}]}],"id":{"product":"b6cb1e645c374b3e92e6a0688121990e","version":"f64c083f0fcc48daa6ba1260da542139"},"installation":{"command":"CP041563.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG001200JWJNK","target_guid":"452340a5-3047-3130-3230-304a574a4e4b","type":"sas"},{"id":"EG000600JWJNH","target_guid":"452340a5-3047-3030-3630-304a574a4e48","type":"sas"},{"id":"EG000300JWSJP","target_guid":"452340a5-3047-3030-3330-304a57534a50","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T19:32:58","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This firmware fixes a potential reliability condition and the cause of a potential hang.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001200JWJNK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG000600JWJNH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG000300JWSJP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5974184","datemodified":"2021-05-18T02:27:54","file_list":["./usr/lib/i386-linux-gnu/firmware-system-u17-2.90_2021_04_29-1.1","./usr/lib/i386-linux-gnu/firmware-system-u17-2.90_2021_04_29-1.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-system-u17-2.90_2021_04_29-1.1/.setup","./usr/lib/i386-linux-gnu/firmware-system-u17-2.90_2021_04_29-1.1/CP047951.xml","./usr/lib/i386-linux-gnu/firmware-system-u17-2.90_2021_04_29-1.1/U17_2.90_04_29_2021.signed.flash","./usr/lib/i386-linux-gnu/firmware-system-u17-2.90_2021_04_29-1.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-system-u17-2.90_2021_04_29-1.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP047951.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP047951.scexe"],"md5sum":"5d86cf09bd9e9d4b6647d376760186ce","name":"firmware-system-u17-2.90_2021_04_29-1.1.i386.rpm","release":"2021-05-18T02:16:20","revision":"0","sha1sum":"110b184db52f28bfc1acdee40057ee281e5ee98d","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021"}],"id":{"product":"662f02886372406fa85fa3e657c2b940","version":"7ca6bc6930bb45bc9c0b4b9f6a387a47"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HPE ProLiant Agentless Management Service (<strong>AMS</strong>) and HPE SNMP Agents (<strong>SNMP Agents</strong>) are both running.&nbsp; HPE does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager 8.0.0 or later, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、iLOとの通信ができない場合に失敗します。  これは、HPE ProLiant Agentless Management Service (<strong>AMS</strong>)およびHPE SNMPエージェント(<strong>SNMP Agents</strong>)の両方が実行されているときに発生します。  HPEでは、AMSおよびSNMPエージェントを同時に実行させないことを推奨します。  「iLO device not found」エラーが発生した場合、AMSまたはSNMPエージェントを停止させて、再度フラッシュコンポーネントを実行します。<br />\n<br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を見て下さい。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前の手順で確認したディレクトリに移動し、コマンドプロンプトに‘./hpsetup’を入力するとhpsetupを実行します。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上のSmart Update Manager 8.0.0以降を使用して実行できます。</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>USB Key Creator Utilityを使用して、HP Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant DL580 Gen9 (U17) Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-17T02:27:30","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","latest_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000016 (CPUID 306F4) and 0x00B00003A (CPUID 406F1).<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000019 (CPUID 306F4) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"}],"sw_keys":[{"name":"U17","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component contains version 12.0.1192.0 of the Emulex Storport driver for Extended Systems which provides Fibre Channel over Ethernet-Host Bus Adapter driver support for HPE Storage RAID Arrays."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"2040856","datemodified":"2021-08-27T06:10:12","file_list":["brcmdrvr-fcoe-12.0.1192.0-21.exe","cp048542.xml","cpqsetup.exe","ElxCNAInstaller.dll","install.xml","SysConfig.frm","SysConfig.frm.ja"],"md5sum":"6039642b77b6876f28e7928b91fdf6af","name":"cp048542.exe","release":"2021-08-27T06:06:12","revision":"0","sha1sum":"cfbecc11a3747b307891e53b869e48f3557ae6c6","size":"1MB","target_guids":[],"type_of_change":"1","version":"12.0.1192.0"}],"id":{"product":"0ee36403248c4f4ba3fe8fb25a7e216d","version":"9d6b22b6769b4a88bc59c5a99930dde6"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>&nbsp;</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation.</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Fibre Channel Over Ethernet Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2012R2/2016"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T11:01:05","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p style=\"margin-left:0in; margin-right:0in\">Updated to driver version 12.0.1192.0</p>\n\n<p>&nbsp;</p>\n\n<p>Removed the raw driver file folder.&nbsp; The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:<br />\n<br />\n&nbsp;&nbsp;&nbsp; brcmdrvr-fcoe-version.exe /q2 extract=2<br />\n<br />\nThe extracted files are located:<br />\n<br />\n&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Broadcom\\Drivers\\FCoE-version<br />\n<br />\nEach kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,<br />\n<br />\n&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Broadcom\\Drivers\\FCoE-version\\x64\\win2012</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"}],"sw_keys":[{"name":"elxcna.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"},{"name":"elxcna.sys","sw_key_expectedpath":"%programfiles%\\Broadcom\\AutoPilot Installer\\FCoE\\Drivers\\Storport\\x64\\Win2016"},{"name":"elxcna.sys","sw_key_expectedpath":"%programfiles%\\Broadcom\\AutoPilot Installer\\FCoE\\Drivers\\Storport\\x64\\Win2012R2"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB002000GWFGH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SNEMOTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757464748","Version":"HPG3"},{"DeviceName":"MB001000GWFGF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SNEMOTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757464746","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB002000GWFGH and MB001000GWFGF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB002000GWFGH and MB001000GWFGF Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16828146","datemodified":"2021-08-30T19:38:33","file_list":["/CP048317_BUILD_2.data","/CP048317.vmexe","/CP048317.vmexe64","/CP048317.vmfile","/CP048317_VMw.zip","/CP048317.xml","/payload.json","/CP048317_VMw.zip/index.xml","/CP048317_VMw.zip/vendor-index.xml","/CP048317_VMw.zip/metadata.zip","/CP048317_VMw.zip/vib20/CP048317/HPE_bootbank_CP048317_HPG3.2-7.0.0.15843807.vib","/CP048317_VMw.zip/metadata.zip/vendor-index.xml","/CP048317_VMw.zip/metadata.zip/vmware.xml","/CP048317_VMw.zip/metadata.zip/vibs/CP048317--411072492867730887.xml","/CP048317_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048317_HPG3.2-7.0.0.15843807.xml"],"md5sum":"7e680fb6770aa98a705de7ab65c306e8","name":"CP048317.zip","release":"2021-08-30T19:32:50","revision":"0","sha1sum":"e2c247c8856b368271d9368603f1f380a9e4acf4","size":"16MB","target_guids":["4d2340a5-3042-3230-3030-304757464748","4d2340a5-3042-3130-3030-304757464746"],"type_of_change":"0","version":"HPG3","vib_list":[{"name":"CP048317","version":"HPG3.2-7.0.0.15843807"}]}],"id":{"product":"38555f7d1f134877a75c17953659a8a3","version":"c64b637ef61a427bb6116124abaa3868"},"installation":{"command":"CP040652.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB002000GWFGH and MB001000GWFGF Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB002000GWFGHおよびMB001000GWFGFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB002000GWFGH","target_guid":"4d2340a5-3042-3230-3030-304757464748","type":"sata"},{"id":"MB001000GWFGF","target_guid":"4d2340a5-3042-3130-3030-304757464746","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-04T09:36:15","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB001000GWFGF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB002000GWFGH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VS003840KWXFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"85031G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3330-3834-304b57584651","Version":"85031G00"},{"DeviceName":"VS001920KWXFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"85031G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3130-3932-304b57584650","Version":"85031G00"},{"DeviceName":"VS000960KWXFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"85031G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3030-3936-304b5758464e","Version":"85031G00"},{"DeviceName":"VS000480KXALB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"85031G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3030-3438-304b58414c42","Version":"85031G00"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following NVME drive models: VS000480KXALB, VS000960KWXFN, VS001920KWXFP and VS003840KWXFQ"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のNVMEドライブモデルのファームウェアを提供します。VS000480KXALB、VS000960KWXFN、VS001920KWXFP、およびVS003840KWXFQ"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for&nbsp;VMware ESXi -&nbsp;&nbsp;VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN Drives.<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;&nbsp;85031G00</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;&nbsp;85030G00</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;&nbsp;85030G00</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Fixes for various drive reliability enhancements and code fixes accumulated since the last initial release, as well as a change to disable MCTP over PCIe VDM function to satisfy certain HPE platform environments.</li>\n</ul>\n\n<p><strong>Known Issues:</strong></p>\n\n<ul>\n\t<li><strong>&nbsp;</strong>Requires iLO5 v2.30 or later, SUM will not detect SSD as applicable for Firmware update for deployment with iLO5 version older than v2.30</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>提供名：</strong><br />\n      オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - VS000480KXALB、VS003840KWXFQ、VS001920KWXFP、およびVS000960KWXFNドライブ<br />\n <br />\n<strong>リリースバージョンおよび/または日付:</strong><br />\n      85031G00</p>\n\n<p><strong>最新の推奨またはクリティカルバージョン：</strong><br />\n       85030G00</p>\n\n<p><strong>前のファームウェアバージョン：</strong><br />\n       85030G00</p>\n\n<p><strong>ファームウェアの関連性:<br />\n      </strong>なし  </p>\n\n<p><strong>改善点/新しい機能：</strong></p>\n\n<p>      なし\n        </p>\n\n<p><strong>修正された問題：</strong></p>\n\n<ul>\n\t<li>前回の初回リリース以降に蓄積されたさまざまなドライブの信頼性の機能強化とコード修正と、特定のHPEプラットフォーム環境を満たすためにMCTP over PCIe VDM機能を無効にする変更の修正です。</li>\n</ul>\n\n<p><strong>既知の問題点:</strong></p>\n\n<ul>\n\t<li><strong> </strong>iLO5 v2.30以降が必要です。SUMは、v2.30より前のバージョンのiLO5を使用した展開のファームウェアアップデートに適用可能としてSSDを検出しません</li>\n</ul>\n"}],"files":[{"bytes":"21550832","datemodified":"2021-06-05T17:50:38","file_list":["/CP048316_BUILD_1.data","/CP048316.vmexe","/CP048316.vmexe64","/CP048316.vmfile","/CP048316_VMw.zip","/CP048316.xml","/payload.json","/CP048316_VMw.zip/index.xml","/CP048316_VMw.zip/vendor-index.xml","/CP048316_VMw.zip/metadata.zip","/CP048316_VMw.zip/vib20/CP048316/HPE_bootbank_CP048316_85031G00.1-7.0.0.15843807.vib","/CP048316_VMw.zip/metadata.zip/vendor-index.xml","/CP048316_VMw.zip/metadata.zip/vmware.xml","/CP048316_VMw.zip/metadata.zip/vibs/CP048316--300479838445225163.xml","/CP048316_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048316_85031G00.1-7.0.0.15843807.xml"],"md5sum":"7beb1dcfa1eaeb5aeb6f7291baa0c834","name":"CP048316.zip","release":"2021-06-09T00:00:00","revision":"2","sha1sum":"c0f1f3ec6322ca9adfee291cbd5f4243e195609c","size":"20MB","target_guids":["562340a5-3053-3330-3834-304b57584651","562340a5-3053-3130-3932-304b57584650","562340a5-3053-3030-3936-304b5758464e","562340a5-3053-3030-3438-304b58414c42"],"type_of_change":"1","version":"85031G00","vib_list":[{"name":"CP048316","version":"85031G00.1-7.0.0.15843807"}]}],"id":{"product":"fc28c0050f9d4a8a94e83f990b230b39","version":"73e13909dc6a4dd785043e96b1bbdb7a"},"installation":{"command":"CP042969.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>Additional information to execute VIB file.</strong></p>\n\n<p><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p>             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul>\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p> </p>\n\n<p><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul>\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul>\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi - VS000480KXALB, VS000960KWXFN, VS001920KWXFP and VS003840KWXFQ Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - VS000480KXALB、VS000960KWXFN、VS001920KWXFP、およびVS003840KWXFQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VS003840KWXFQ","target_guid":"562340a5-3053-3330-3834-304b57584651","type":"nvme"},{"id":"VS001920KWXFP","target_guid":"562340a5-3053-3130-3932-304b57584650","type":"nvme"},{"id":"VS000960KWXFN","target_guid":"562340a5-3053-3030-3936-304b5758464e","type":"nvme"},{"id":"VS000480KXALB","target_guid":"562340a5-3053-3030-3438-304b58414c42","type":"nvme"},{"dev":"2241","subdev":"02F6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1b4b-2241159002f6","type":"pci","ven":"1B4B"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-18T10:26:13","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This is a maintenance release that contains various drive reliability enhancements and code fixes accumulated since the last initial release, as well as a change to disable MCTP over PCIe VDM function to satisfy certain HPE platform environments.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fixes for various drive reliability enhancements and code fixes accumulated since the last initial release, as well as a change to disable MCTP over PCIe VDM function to satisfy certain HPE platform environments.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"VS003840KWXFQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VS000960KWXFN","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VS001920KWXFP","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VS000480KXALB","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox adapter cards."},{"lang":"ja","x_late":"このRPMには、サポートされているHPE Mellanoxアダプターカード用のHPEによるテストと承認済みのLinuxベースMellanox RoCE (RDMA over Converged Ethernet)ドライバーが含まれます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1947212","datemodified":"2021-05-17T22:23:27","file_list":["./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/compat","./lib/modules/4.12.14-120-default/updates/compat/mlx_compat.ko","./lib/modules/4.12.14-120-default/updates/drivers","./lib/modules/4.12.14-120-default/updates/drivers/infiniband","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/ib_cm.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/ib_core.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/ib_ucm.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/ib_umad.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/iw_cm.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/rdma_cm.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/cxgb3","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/cxgb3/iw_cxgb3.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/cxgb4","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/efa","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/efa/efa.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/hfi1","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/i40iw","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/mlx4","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/mlx5","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/mthca","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/mthca/ib_mthca.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/nes","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/nes/iw_nes.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/ocrdma","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/ocrdma/ocrdma.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/qedr","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/qib","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/qib/ib_qib.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/usnic","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/sw","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/sw/rdmavt","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/sw/rxe","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/ipoib","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/iser","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/isert","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/opa_vnic","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/srp","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/srpt","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/4.12.14-120-default/updates/drivers/net","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlx4","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlx4/mlx4_core.ko","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlx4/mlx4_en.ko","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlx5","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlx5/fpga","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlx5/fpga/mlx5_fpga_tools.ko","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/4.12.14-120-default/updates/drivers/nvme","./lib/modules/4.12.14-120-default/updates/drivers/nvme/host","./lib/modules/4.12.14-120-default/updates/drivers/nvme/host/nvme-rdma.ko","./lib/modules/4.12.14-120-default/updates/drivers/nvme/target","./lib/modules/4.12.14-120-default/updates/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/4.12.14-120-default/updates/net","./lib/modules/4.12.14-120-default/updates/net/9p","./lib/modules/4.12.14-120-default/updates/net/9p/9pnet_rdma.ko","./lib/modules/4.12.14-120-default/updates/net/rds","./lib/modules/4.12.14-120-default/updates/net/rds/rds_rdma.ko","./lib/modules/4.12.14-120-default/updates/net/sunrpc","./lib/modules/4.12.14-120-default/updates/net/sunrpc/xprtrdma","./lib/modules/4.12.14-120-default/updates/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/4.12.14-120-default/updates/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/4.12.14-120-default/updates/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/mlnx-ofa_kernel-kmp-default/component.xml"],"md5sum":"faec1f154f75073f8713a066177caf03","name":"mlnx-ofa_kernel-kmp-default-4.9_k4.12.14_120-OFED.4.9.3.1.6.1.sles12sp5.x86_64.rpm","release":"2021-05-17T20:36:12","revision":"0","sha1sum":"7a3774929d466945bd089b80874de840c2b09890","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"4.9"},{"bytes":"1933690","datemodified":"2021-05-17T22:24:56","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/connectx.conf","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d/mlx4.driver","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/security/limits.d/30-libvma-limits.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/82-net-setup-link.rules","./etc/udev/rules.d/90-ib.rules","./sbin/connectx_port_config","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/ibdev2netdev","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_get_vfs.pl","./usr/bin/mlnx_perf","./usr/bin/mlnx_qcn","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/lib/python2.7/site-packages/dcbnetlink.py","./usr/lib/python2.7/site-packages/dcbnetlink.pyc","./usr/lib/python2.7/site-packages/dcbnetlink.pyo","./usr/lib/python2.7/site-packages/genetlink.py","./usr/lib/python2.7/site-packages/genetlink.pyc","./usr/lib/python2.7/site-packages/genetlink.pyo","./usr/lib/python2.7/site-packages/netlink.py","./usr/lib/python2.7/site-packages/netlink.pyc","./usr/lib/python2.7/site-packages/netlink.pyo","./usr/lib/python2.7/site-packages/ofed_le_utils-1.0.3-py2.7.egg-info","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/vma.service","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.0","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.0.0","./usr/lib64/libmlx4-rdmav2.so","./usr/lib64/libmlx5-rdmav2.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.0.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.0.0","./usr/lib64/libvma-debug.so","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.0.2","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vma","./usr/sbin/vmad","./usr/share/doc/packages/ib2ib","./usr/share/doc/packages/ib2ib/README","./usr/share/doc/packages/libibumad","./usr/share/doc/packages/libibumad/AUTHORS","./usr/share/doc/packages/libibumad/COPYING","./usr/share/doc/packages/libibumad/ChangeLog","./usr/share/doc/packages/libibverbs","./usr/share/doc/packages/libibverbs/AUTHORS","./usr/share/doc/packages/libibverbs/COPYING","./usr/share/doc/packages/libibverbs/ChangeLog","./usr/share/doc/packages/libibverbs/README","./usr/share/doc/packages/libmlx4","./usr/share/doc/packages/libmlx4/AUTHORS","./usr/share/doc/packages/libmlx4/COPYING","./usr/share/doc/packages/libmlx4/README","./usr/share/doc/packages/libmlx5","./usr/share/doc/packages/libmlx5/AUTHORS","./usr/share/doc/packages/libmlx5/COPYING","./usr/share/doc/packages/libmlx5/README","./usr/share/doc/packages/librdmacm","./usr/share/doc/packages/librdmacm/AUTHORS","./usr/share/doc/packages/librdmacm/COPYING","./usr/share/doc/packages/librdmacm/README","./usr/share/doc/packages/libvma-9.0.2/README.txt","./usr/share/doc/packages/libvma-9.0.2/VMA_VERSION","./usr/share/doc/packages/libvma-9.0.2/journal.txt","./usr/share/man/man3/umad_addr_dump.3.gz","./usr/share/man/man3/umad_alloc.3.gz","./usr/share/man/man3/umad_attribute_str.3.gz","./usr/share/man/man3/umad_class_str.3.gz","./usr/share/man/man3/umad_close_port.3.gz","./usr/share/man/man3/umad_debug.3.gz","./usr/share/man/man3/umad_done.3.gz","./usr/share/man/man3/umad_dump.3.gz","./usr/share/man/man3/umad_free.3.gz","./usr/share/man/man3/umad_free_ca_namelist.3.gz","./usr/share/man/man3/umad_get_ca.3.gz","./usr/share/man/man3/umad_get_ca_namelist.3.gz","./usr/share/man/man3/umad_get_ca_portguids.3.gz","./usr/share/man/man3/umad_get_cas_names.3.gz","./usr/share/man/man3/umad_get_fd.3.gz","./usr/share/man/man3/umad_get_issm_path.3.gz","./usr/share/man/man3/umad_get_mad.3.gz","./usr/share/man/man3/umad_get_mad_addr.3.gz","./usr/share/man/man3/umad_get_pkey.3.gz","./usr/share/man/man3/umad_get_port.3.gz","./usr/share/man/man3/umad_init.3.gz","./usr/share/man/man3/umad_mad_status_str.3.gz","./usr/share/man/man3/umad_method_str.3.gz","./usr/share/man/man3/umad_open_port.3.gz","./usr/share/man/man3/umad_poll.3.gz","./usr/share/man/man3/umad_recv.3.gz","./usr/share/man/man3/umad_register.3.gz","./usr/share/man/man3/umad_register2.3.gz","./usr/share/man/man3/umad_register_oui.3.gz","./usr/share/man/man3/umad_release_ca.3.gz","./usr/share/man/man3/umad_release_port.3.gz","./usr/share/man/man3/umad_send.3.gz","./usr/share/man/man3/umad_set_addr.3.gz","./usr/share/man/man3/umad_set_addr_net.3.gz","./usr/share/man/man3/umad_set_grh.3.gz","./usr/share/man/man3/umad_set_grh_net.3.gz","./usr/share/man/man3/umad_set_pkey.3.gz","./usr/share/man/man3/umad_size.3.gz","./usr/share/man/man3/umad_status.3.gz","./usr/share/man/man3/umad_unregister.3.gz","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml"],"md5sum":"07940644bf0d869e7b5c990582c5856e","name":"mlnx-ofa_kernel-4.9-OFED.4.9.3.1.6.1.sles12sp5.x86_64.rpm","release":"2021-05-17T20:36:12","revision":"0","sha1sum":"a10c70e9c9e13c1d49da28c7e484149f3e1a34a4","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"4.9"}],"id":{"product":"38f8dc6c0e3046598e2c4afc7a94419e","version":"6c03d6881c44474a8f7d0c8000fa0e71"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"11.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPMs to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-4.9&quot; RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using 4.12.14-120-default kernel or any future errata:<br />\n<br />\n<strong># rpm -Uvh&nbsp;mlnx-ofa_kernel-4.9-OFED.4.9.3.1.6.1.sles12sp5.x86_64.rpm&nbsp;mlnx-ofa_kernel-kmp-default-4.9_k4.12.14_120-OFED.4.9.3.1.6.1.sles12sp5.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for SUSE LINUX Enterprise Server 12 SP5 (AMD64/EM64T)"},{"lang":"ja","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) ドライバーfor SUSE LINUX Enterprise Server 12 SP5 (AMD64/EM64T)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-17T16:52:07","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>The following changes and new features are added in version 4.9:</strong></p>\n\n<ul>\n\t<li><strong>For ConnectX-5 Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Option to dump configuration space via the devlink tool in order to improve debug capabilities.</li>\n\t<li>The conventional TX descriptor (WQE or Work Queue Element) describes a single packet for transmission. Added driver support for the HW feature of multi-packet TX WQEs in XDP transmit flows. With this, the HW becomes capable of working with a new and improved WQE layout that describes several packets. In effect, this feature saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>GENEVE encapsulation/decapsulation rules offload.</li>\n\t<li>Driver support for the hardware feature of multi-packet Tx to work with a new and improved WQE layout that describes several packets instead of a single packet for XDP transmission flows. This saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>Updating CT (Connection Tracking) rules using the software steering mechanism.</li>\n\t<li>Updating remote mirroring rules using the software steering mechanism.<br />\n\t&nbsp;</li>\n\t<li><strong>For ConnectX-4&nbsp;Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Exposed rx_prio[p]_discards discard counters per priority that count the number of received packets dropped due to lack of buffers on the physical port.</li>\n\t<li>Reporting TSO and CSUM offload capabilities for MPLS tagged traffic and, allowed the kernel stack to use these offloads.</li>\n\t<li>mlx5e Max Combined Channels Increased the driver&rsquo;s maximal combined channels value from 64 to 128 (however, note that OOB value will not cross 64). 128 is the upper bound. Lower maximal value can be seen on the host, depending on the number of cores and MSIX&#39;s configured by the firmware.</li>\n\t<li>Added the following RoCE accelerator counters:\n\t<ul>\n\t\t<li>roce_adp_retrans - counts the number of adaptive retransmissions for RoCE traffic.</li>\n\t\t<li>roce_adp_retrans_to - counts the number of times RoCE traffic reached timeout due to adaptive retransmission.</li>\n\t\t<li>roce_slow_restart - counts the number of times RoCE slow restart was used.</li>\n\t\t<li>roce_slow_restart_cnps - counts the number of times RoCE slow restart generated CNP packets roce_slow_restart_trans - counts the number of times RoCE slow restart changed state to slow restart.</li>\n\t</ul>\n\t</li>\n\t<li>User to register memory regions with a relaxed ordering access flag through experimental verbs. This can enhance performance, depending on architecture and scenario.<br />\n\t&nbsp;</li>\n\t<li><strong>For&nbsp;All HCA&#39;s</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Output ibdev2netdev tool output was changed such that the bonding device now points at the bond instead of the slave interface.</li>\n\t<li>Monitoring and recovering from errors that occur on the RX queue, such as cookie errors and timeout.</li>\n\t<li>Improved GSO (Generic Segmentation Offload) workload performance by decreasing doorbells usage to the minimum required.</li>\n\t<li>TX CQE (Completion Queue Element) compression. Saves on outgoing PCIe bandwidth by compressing CQEs together. Disabled by default. Configurable via private flags of ethtool.</li>\n\t<li>Firmware Versions Query via Devlink :Added the option to query for running and stored firmware versions using the devlink tool.</li>\n\t<li>Firmware Flash Update via Devlink :Added the option to update the firmware image in the flash using the devlink tool. Usage: devlink dev flash file .mfa2 For further information on how to perform this update, see &quot;Updating Firmware Using ethtool/devlink and .mfa2 File&quot; section in MFT User Manual.</li>\n\t<li>WQE (Work Queue Element) dump, triggered by an error on Rx/Tx reporters. In addition, some dumps (not triggered by an error) can be retrieved by the user via devlink health reporters.</li>\n\t<li>GENEVE tunneled hardware offloads of TSO, CSUM and RSS.</li>\n\t<li>TCP segmentation and checksum offload support for MPLS-tagged traffic.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 4.9:</strong></p>\n\n<ul>\n\t<li>An issue where injecting EEH (Extended Error Handlng) may cause extra Kernel prints, such as: &ldquo;EEH: Might be infinite loop in mlx5_core driver&rdquo; was fixed.</li>\n\t<li>RPM-based OSs with non-default kernels, using repositories after re-creating the installer (using --add-kernel-support) were&nbsp;resulting&nbsp;in improper installation of the drivers.</li>\n\t<li>A typo in perftest package where help messages wrongly displayed the conversion result between Gb/s and MB/s (20^2 instead of 2^20).</li>\n\t<li>When one of the LAG slaves went down, LAG deactivation failed, ultimately causing bandwidth degradation.</li>\n\t<li>The mlx5 driver maintains a subdirectory for every open eth port in /sys/kernel/debug/. For the default network namespace, the sub-directory name is the name of the interface, like &quot;eth8&quot;. The new convention for the network interfaces moved to the non-default network namespaces is the interfaces name followed by &quot;@&quot; and the port&#39;s PCI ID. For example: &quot;eth8@0000:af:00.3&quot;.</li>\n\t<li>&quot;openibd&quot; script load used to fail when esp6_offload module did not load successfully.</li>\n\t<li>Added dependency of package mpi-selectors on perl-Getopt-Long system package. On minimal installs of RPM-based OSs, installing mpi-selectros will also install the required system package perl-Getopt-Long.</li>\n\t<li>During certain rare scenarios, due to Rx page not being replenished, the same page fragment mistakenly became assigned to two different Rx descriptors.</li>\n\t<li>Driver load issue existed with Errata-kernel on SLES15 SP1.</li>\n\t<li>An issue in the Hairpin feature which prevented adding hairpin flows using TC tool was fixed.</li>\n\t<li>WQ (Work Queue)&nbsp;queue flushing was not handled properly in the event of EEH.</li>\n\t<li>A rare kernel crash scenario when exiting an application that uses RMPP mads intensively.</li>\n\t<li>A possible kernel crash scenario when AER/slot reset in done in parallel to user space commands execution.</li>\n\t<li>Added missing ECN (Explicit Congestion Notification) configuration under sysfs for PFs in SwitchDev mode.</li>\n\t<li>When firmware response time to commands became very long, some commands failed upon timeout. The driver may have then triggered a timeout completion on the wrong entry, leading to a NULL pointer call trace.</li>\n\t<li>Added driver support for kernels with the old XDP_REDIRECT infrastructure that uses the following NetDev operations: .ndo_xdp_flush and .ndo_xdp_xmit.</li>\n\t<li>Usage of --excludedocs Open MPI RPM option resulted in the removal of non-documentation related files.</li>\n\t<li>Disabled automated loading of some modules through udev triggers to preserve the startup process of previous MLNX_OFED versions.</li>\n\t<li>Reference count (refcount) for RDMA connection ID (cm_id) was not incremented in rdma_resolve_addr() function, resulting in a cm_id use-after-free access. A fix was applied to increment the cm_id refcount</li>\n\t<li>A race condition which caused kernel panic when moving two ports to SwitchDev mode at the same time.</li>\n\t<li>Allowed accessing sysfs hardware counters in SwitchDev mode</li>\n\t<li>Function smp_processor_id() is called in the RX page recycle flow to determine the core to run on. This is intended to run in NAPI context. However, due to a bug in backporting, the RX page recycle was mistakenly called also in the RQ close flow when not needed.</li>\n\t<li>Port link state was automatically changed (without admin state involvement) to &quot;UP&quot; after reboot.</li>\n\t<li>ConnectX-3 adapter cards froze when running over SLES 11 OS.</li>\n\t<li>RDMA CM (Remote Direct Memory Access Communation Manager) connection failed when port space was small.</li>\n\t<li>Traffic mirroring with OVS (Open VSwitch)offload and non-offload over VxLAN interface is now supported. Note: For kernel 4.9, make sure to use a dedicated OVS version.</li>\n\t<li>When working with VF LAG while the bond device is in active-active mode, running fwreset would result in unequal traffic on both PFs, and PFs would not reach line rate.</li>\n\t<li>When bond was created over VF (Virtuaal Function)&nbsp;netdevices in SwitchDev mode, the VF netdevice would be treated as representor netdevice. This caused the mlx5_core driver to crash in case it received netdevice events related to bond device.</li>\n\t<li>An issue where following a bad affinity occurrence in VF LAG mode, traffic was sent after the port went up/down in the switch.</li>\n\t<li>Added support for VLAN (Virtual Local Area Network)&nbsp;header rewrite on CentOS 7.2 OS.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>The following changes and new features are added in version 4.9:</strong></p>\n\n<ul>\n\t<li><strong>For ConnectX-5 Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Option to dump configuration space via the devlink tool in order to improve debug capabilities.</li>\n\t<li>The conventional TX descriptor (WQE or Work Queue Element) describes a single packet for transmission. Added driver support for the HW feature of multi-packet TX WQEs in XDP transmit flows. With this, the HW becomes capable of working with a new and improved WQE layout that describes several packets. In effect, this feature saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>GENEVE encapsulation/decapsulation rules offload.</li>\n\t<li>Driver support for the hardware feature of multi-packet Tx to work with a new and improved WQE layout that describes several packets instead of a single packet for XDP transmission flows. This saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>Updating CT (Connection Tracking) rules using the software steering mechanism.</li>\n\t<li>Updating remote mirroring rules using the software steering mechanism.<br />\n\t&nbsp;</li>\n\t<li><strong>For ConnectX-4&nbsp;Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Exposed rx_prio[p]_discards discard counters per priority that count the number of received packets dropped due to lack of buffers on the physical port.</li>\n\t<li>Reporting TSO and CSUM offload capabilities for MPLS tagged traffic and, allowed the kernel stack to use these offloads.</li>\n\t<li>mlx5e Max Combined Channels Increased the driver&rsquo;s maximal combined channels value from 64 to 128 (however, note that OOB value will not cross 64). 128 is the upper bound. Lower maximal value can be seen on the host, depending on the number of cores and MSIX&#39;s configured by the firmware.</li>\n\t<li>Added the following RoCE accelerator counters:\n\t<ul>\n\t\t<li>roce_adp_retrans - counts the number of adaptive retransmissions for RoCE traffic.</li>\n\t\t<li>roce_adp_retrans_to - counts the number of times RoCE traffic reached timeout due to adaptive retransmission.</li>\n\t\t<li>roce_slow_restart - counts the number of times RoCE slow restart was used.</li>\n\t\t<li>roce_slow_restart_cnps - counts the number of times RoCE slow restart generated CNP packets roce_slow_restart_trans - counts the number of times RoCE slow restart changed state to slow restart.</li>\n\t</ul>\n\t</li>\n\t<li>User to register memory regions with a relaxed ordering access flag through experimental verbs. This can enhance performance, depending on architecture and scenario.<br />\n\t&nbsp;</li>\n\t<li><strong>For&nbsp;All HCA&#39;s</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Output ibdev2netdev tool output was changed such that the bonding device now points at the bond instead of the slave interface.</li>\n\t<li>Monitoring and recovering from errors that occur on the RX queue, such as cookie errors and timeout.</li>\n\t<li>Improved GSO (Generic Segmentation Offload) workload performance by decreasing doorbells usage to the minimum required.</li>\n\t<li>TX CQE (Completion Queue Element) compression. Saves on outgoing PCIe bandwidth by compressing CQEs together. Disabled by default. Configurable via private flags of ethtool.</li>\n\t<li>Firmware Versions Query via Devlink :Added the option to query for running and stored firmware versions using the devlink tool.</li>\n\t<li>Firmware Flash Update via Devlink :Added the option to update the firmware image in the flash using the devlink tool. Usage: devlink dev flash file .mfa2 For further information on how to perform this update, see &quot;Updating Firmware Using ethtool/devlink and .mfa2 File&quot; section in MFT User Manual.</li>\n\t<li>WQE (Work Queue Element) dump, triggered by an error on Rx/Tx reporters. In addition, some dumps (not triggered by an error) can be retrieved by the user via devlink health reporters.</li>\n\t<li>GENEVE tunneled hardware offloads of TSO, CSUM and RSS.</li>\n\t<li>TCP segmentation and checksum offload support for MPLS-tagged traffic.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 4.9:</strong></p>\n\n<ul>\n\t<li>An issue where injecting EEH (Extended Error Handlng) may cause extra Kernel prints, such as: &ldquo;EEH: Might be infinite loop in mlx5_core driver&rdquo; was fixed.</li>\n\t<li>RPM-based OSs with non-default kernels, using repositories after re-creating the installer (using --add-kernel-support) were&nbsp;resulting&nbsp;in improper installation of the drivers.</li>\n\t<li>A typo in perftest package where help messages wrongly displayed the conversion result between Gb/s and MB/s (20^2 instead of 2^20).</li>\n\t<li>When one of the LAG slaves went down, LAG deactivation failed, ultimately causing bandwidth degradation.</li>\n\t<li>The mlx5 driver maintains a subdirectory for every open eth port in /sys/kernel/debug/. For the default network namespace, the sub-directory name is the name of the interface, like &quot;eth8&quot;. The new convention for the network interfaces moved to the non-default network namespaces is the interfaces name followed by &quot;@&quot; and the port&#39;s PCI ID. For example: &quot;eth8@0000:af:00.3&quot;.</li>\n\t<li>&quot;openibd&quot; script load used to fail when esp6_offload module did not load successfully.</li>\n\t<li>Added dependency of package mpi-selectors on perl-Getopt-Long system package. On minimal installs of RPM-based OSs, installing mpi-selectros will also install the required system package perl-Getopt-Long.</li>\n\t<li>During certain rare scenarios, due to Rx page not being replenished, the same page fragment mistakenly became assigned to two different Rx descriptors.</li>\n\t<li>Driver load issue existed with Errata-kernel on SLES15 SP1.</li>\n\t<li>An issue in the Hairpin feature which prevented adding hairpin flows using TC tool was fixed.</li>\n\t<li>WQ (Work Queue)&nbsp;queue flushing was not handled properly in the event of EEH.</li>\n\t<li>A rare kernel crash scenario when exiting an application that uses RMPP mads intensively.</li>\n\t<li>A possible kernel crash scenario when AER/slot reset in done in parallel to user space commands execution.</li>\n\t<li>Added missing ECN (Explicit Congestion Notification) configuration under sysfs for PFs in SwitchDev mode.</li>\n\t<li>When firmware response time to commands became very long, some commands failed upon timeout. The driver may have then triggered a timeout completion on the wrong entry, leading to a NULL pointer call trace.</li>\n\t<li>Added driver support for kernels with the old XDP_REDIRECT infrastructure that uses the following NetDev operations: .ndo_xdp_flush and .ndo_xdp_xmit.</li>\n\t<li>Usage of --excludedocs Open MPI RPM option resulted in the removal of non-documentation related files.</li>\n\t<li>Disabled automated loading of some modules through udev triggers to preserve the startup process of previous MLNX_OFED versions.</li>\n\t<li>Reference count (refcount) for RDMA connection ID (cm_id) was not incremented in rdma_resolve_addr() function, resulting in a cm_id use-after-free access. A fix was applied to increment the cm_id refcount</li>\n\t<li>A race condition which caused kernel panic when moving two ports to SwitchDev mode at the same time.</li>\n\t<li>Allowed accessing sysfs hardware counters in SwitchDev mode</li>\n\t<li>Function smp_processor_id() is called in the RX page recycle flow to determine the core to run on. This is intended to run in NAPI context. However, due to a bug in backporting, the RX page recycle was mistakenly called also in the RQ close flow when not needed.</li>\n\t<li>Port link state was automatically changed (without admin state involvement) to &quot;UP&quot; after reboot.</li>\n\t<li>ConnectX-3 adapter cards froze when running over SLES 11 OS.</li>\n\t<li>RDMA CM (Remote Direct Memory Access Communation Manager) connection failed when port space was small.</li>\n\t<li>Traffic mirroring with OVS (Open VSwitch)offload and non-offload over VxLAN interface is now supported. Note: For kernel 4.9, make sure to use a dedicated OVS version.</li>\n\t<li>When working with VF LAG while the bond device is in active-active mode, running fwreset would result in unequal traffic on both PFs, and PFs would not reach line rate.</li>\n\t<li>When bond was created over VF (Virtuaal Function)&nbsp;netdevices in SwitchDev mode, the VF netdevice would be treated as representor netdevice. This caused the mlx5_core driver to crash in case it received netdevice events related to bond device.</li>\n\t<li>An issue where following a bad affinity occurrence in VF LAG mode, traffic was sent after the port went up/down in the switch.</li>\n\t<li>Added support for VLAN (Virtual Local Area Network)&nbsp;header rewrite on CentOS 7.2 OS.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800026","languages":[{"lang":"tw","x_late":"軟體 - 管理"},{"lang":"en","x_late":"Software - Management"},{"lang":"ko","x_late":"소프트웨어 - 관리"},{"lang":"ja","x_late":"ソフトウェア - マネジメント"},{"lang":"cn","x_late":"软件 - 管理"}]}],"description":[{"lang":"en","x_late":"The HPE SMX Provider Bundle Smart Component for ESXi 7.0 includes the latest HPE Common Information Model (CIM) Providers."},{"lang":"ja","x_late":"HPE SMXプロバイダーバンドルSmartコンポーネントfor ESXi 7.0には、最新のHPE Common Information Model (CIM) プロバイダーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"21583236","datemodified":"2021-07-21T21:04:37","file_list":["/cp044960.xml","/smxProvider_700.03.16.00__1_.12_14828939_signed_component_1567546.zip","/smxProvider_700.03.16.00__1_.12_14828939_signed_component_1567546.zip/index.xml","/smxProvider_700.03.16.00__1_.12_14828939_signed_component_1567546.zip/vendor-index.xml","/smxProvider_700.03.16.00__1_.12_14828939_signed_component_1567546.zip/metadata.zip","/smxProvider_700.03.16.00__1_.12_14828939_signed_component_1567546.zip/vib20/smx-provider/HPE_bootbank_smx-provider_700.03.16.00.12-14828939.vib","/smxProvider_700.03.16.00__1_.12_14828939_signed_component_1567546.zip/metadata.zip/vendor-index.xml","/smxProvider_700.03.16.00__1_.12_14828939_signed_component_1567546.zip/metadata.zip/vmware.xml","/smxProvider_700.03.16.00__1_.12_14828939_signed_component_1567546.zip/metadata.zip/vibs/smx-provider--4679724045287253549.xml","/smxProvider_700.03.16.00__1_.12_14828939_signed_component_1567546.zip/metadata.zip/bulletins/smxProvider_700.03.16.00.12-14828939.xml"],"md5sum":"6f2424735a5746c2be66b5457a3110d7","name":"cp044960.zip","release":"2021-07-21T21:01:09","revision":"0","sha1sum":"cc9a39ca3e7920ed595fe8a246d66e21ca0c720b","size":"20MB","target_guids":[],"type_of_change":"1","version":"2020.04.01","vib_list":[{"name":"smx-provider","version":"700.03.16.00.12-14828939"}]}],"id":{"product":"f5ab6808fff6474c8daabc965dddfa7b","version":"3ce322f96dcc4c87be5141ab3b3ef867"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To&nbsp;remotely install&nbsp;this&nbsp;bundle&nbsp; online using the HP Smart Update Manager (HPSUM) from the HP Service Pack for ProLiant (SPP):</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Copy&nbsp;this driver component&nbsp;to the directory<em> /SPP20xxxxx/hp/swpackages</em> on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.</li>\n\t<li>Change directories to <em>/hp/swpackages</em> and execute&nbsp;./hpsum.</li>\n\t<li>Select the &quot;next&quot; button.</li>\n\t<li>Click &quot;Add Single Target.&quot;</li>\n\t<li>Enter&nbsp;the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow HP Smart Update Manager&nbsp;instructions&nbsp;to complete the driver update.</li>\n</ol>\n\n<p><br />\n<strong>To&nbsp;install this bundle using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the component zip file to extract the driver offline bundle.</li>\n\t<li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li>\n</ol>\n\n<p>Refer to VMware documentation for information on the esxcli commands</p>\n"},{"lang":"ja","x_late":"<p><strong>HP Service Pack for ProLiant (SPP)からHP Smart Update Manager (HPSUM)を使用して、このバンドルをオンラインでリモートインストールするには：</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>このドライバーコンポーネントをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバーにUSBキーをマウントします。</li>\n\t<li><em>/hp/swpackages</em>にディレクトリを変更し、./hpsumを実行します。</li>\n\t<li>「次へ」ボタンを選択します。</li>\n\t<li>「シングルターゲットの追加」をクリックします。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>HP Smart Update Manager 手順に従って、ドライバーアップデートを完了します。</li>\n</ol>\n\n<p><br />\n<strong>VMwareツールを使用して、このバンドルをインストールするには：</strong></p>\n\n<ol>\n\t<li>ドライバーオフラインバンドルを抽出するために、このコンポーネントのzipファイルを解凍します。</li>\n\t<li>オフラインバンドルをインストールするには、「esxcli」コマンドを実行します。</li>\n</ol>\n\n<p>esxcliコマンドの詳細については、VMwareのドキュメントを参照してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE SMX Provider Bundle Smart Component for ESXi 7.0"},{"lang":"ja","x_late":"HPE SMXプロバイダーバンドルSmartコンポーネントfor ESXi 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"22000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-30T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Add new supported servers</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated supported server list.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"}],"sw_keys":[{"name":"smxProvider:700.03.16.00.12-14828939","sw_key_expectedpath":"software.component:vmware:zip"},{"name":"smx-provider:700.03.16.00.12-14828939","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH0300JDYTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFLRCD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3330-304a44595448","Version":"HPD6"},{"DeviceName":"EH0450JDYTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFLRCD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3435-304a4459544b","Version":"HPD6"},{"DeviceName":"EH0600JDYTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFLRCD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3630-304a4459544c","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EH0300JDYTH, EH0450JDYTK and EH0600JDYTL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - EH0300JDYTH, EH0450JDYTK&nbsp;and EH0600JDYTL Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong>&nbsp;&nbsp;<br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3659808","datemodified":"2021-07-24T05:38:04","file_list":["cp048515.xml","cpqsetup.exe","HKFLRCD6.rel","payload.json","setup.dll"],"md5sum":"06e0a06312d507f89ecdb73dd6906692","name":"cp048515.exe","release":"2021-07-24T05:30:13","revision":"0","sha1sum":"f673e5f8982e4d852d1d15637259200b0e26a7f8","size":"3MB","target_guids":["002340a5-4500-3048-3330-304a44595448","002340a5-4500-3048-3435-304a4459544b","002340a5-4500-3048-3630-304a4459544c"],"type_of_change":"1","version":"HPD6"}],"id":{"product":"da89b89bd1534fddb60af7c195cb4d11","version":"de336cf3f1604ebd9315c64bd804fd2d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EH0300JDYTH, EH0450JDYTK and EH0600JDYTL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EH0300JDYTH、EH0450JDYTK、およびEH0600JDYTLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"EH0300JDYTH","target_guid":"002340a5-4500-3048-3330-304a44595448","type":"sas"},{"id":"EH0450JDYTK","target_guid":"002340a5-4500-3048-3435-304a4459544b","type":"sas"},{"id":"EH0600JDYTL","target_guid":"002340a5-4500-3048-3630-304a4459544c","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T09:50:27","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH0600JDYTL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0300JDYTH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0450JDYTK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager（SUM）と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5880904","datemodified":"2021-05-18T16:13:41","file_list":["SignedImageInstaller64.dll","U25_2.90_04_29_2021.signed.flash","cp047894.xml","cpqsetup.exe","cpqsysio64.sys"],"md5sum":"224b09dc3478816291434bb6a3dd0d76","name":"cp047894.exe","release":"2021-05-18T15:57:05","revision":"0","sha1sum":"35379585674d707da86f5ed57819808abb1ad5af","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021"}],"id":{"product":"d4f71c14a668436aace9f00c7057e76e","version":"c5c07ab64fa6445d9eeec101d6024784"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant XL270d (U25) Accelerator Tray"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant XL270d (U25) アクセラレータトレイ"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-06T16:23:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","latest_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358.  These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390.  These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"}],"sw_keys":[{"name":"U25","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900374","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the boot BIOS and firmware of HPE QLogic Mezzanine Fibre Channel host bus adapters."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"2516264","datemodified":"2021-08-27T05:06:07","file_list":["QLAFWUpdate.exe","adapters.properties","cp048715.xml","cpqsetup.exe","hld60404.bin","installer.dll","payload.json","qlafwupdate.properties","qlafwupdate.txt","qlsdm.dll","reference.xml","runquery.bat","x103Cx1939/BC26xx.DAT","x103Cx1939/FWA83xxB.DAT","x1590x00F9/PEP27BC.dat","x1590x00F9/Q27FBC.dat","x1590x00F9/Q27FWA.dat","x1590x00FA/PEP27BC.dat","x1590x00FA/Q27FBC.dat","x1590x00FA/Q27FWA.dat","x1590x0203/PEP27BC.dat","x1590x0203/Q27FBC.dat","x1590x0203/Q27FWA.dat","x1590x0204/PEP27BC.dat","x1590x0204/Q27FBC.dat","x1590x0204/Q27FWA.dat","x1590x022D/PEP27BC.dat","x1590x022D/Q27FBC.dat","x1590x022D/Q27FWA.dat"],"md5sum":"4b13ad7b2586fbbdded9f292e16eb73b","name":"cp048715.exe","release":"2021-08-27T04:51:25","revision":"0","sha1sum":"37f0685c1d67370fdb7af622601daf70e5664269","size":"2MB","target_guids":[],"type_of_change":"1","version":"2021.10.01"}],"id":{"product":"3e5b5262136a4e1fbb2737e4abf4a51f","version":"32a6eaeec4434f93a86ddfb3e53b2f06"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component number.<br />\n<br />\nFrom that drive and directory, execute the downloaded file.<br />\n<br />\nClick the &quot;Install&quot; button to proceed with the installation.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for QLogic Mezzanine Fibre Channel Host Bus Adapters - Microsoft Windows Server 2012R2/2016/2019 (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-18T06:27:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated&nbsp;the Firmware/BIOS/UEFI packages for&nbsp;16 Gb&nbsp;products.</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>MBI</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE QMH2672 16Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>6.04.04</td>\n\t\t\t<td>8.08.232</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.43</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"qlogic","sw_key_expectedpath":"firmware:qlogic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"VMware ESXi 6.7 Mellanox Ethernet driver for ConnectX-3(Pro) devices"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1321287","datemodified":"2020-11-24T07:55:38","file_list":["/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip","/cp046262.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/doc/README.txt","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/doc/release_note_nmlx4-core_3.17.70.1-1OEM.670.0.0.8169922.pdf","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/doc/release_note_nmlx4-en_3.17.70.1-1OEM.670.0.0.8169922.pdf","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/doc/release_note_nmlx4-rdma_3.17.70.1-1OEM.670.0.0.8169922.pdf","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip/index.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip/vendor-index.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip/metadata.zip","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip/vib20/nmlx4-core/MEL_bootbank_nmlx4-core_3.17.70.1-1OEM.670.0.0.8169922.vib","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip/vib20/nmlx4-en/MEL_bootbank_nmlx4-en_3.17.70.1-1OEM.670.0.0.8169922.vib","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip/vib20/nmlx4-rdma/MEL_bootbank_nmlx4-rdma_3.17.70.1-1OEM.670.0.0.8169922.vib","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip/metadata.zip/vendor-index.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip/metadata.zip/vmware.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip/metadata.zip/vibs/nmlx4-core-681000306.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip/metadata.zip/vibs/nmlx4-en-914539524.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip/metadata.zip/vibs/nmlx4-rdma-1057846885.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip/metadata.zip/bulletins/VMW-ESX-6.7.0-nmlx4_en-3.17.70.1.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip/metadata.zip/bulletins/VMW-ESX-6.7.0-nmlx4_rdma-3.17.70.1.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip/metadata.zip/bulletins/VMW-ESX-6.7.0-nmlx4_core-3.17.70.1.xml"],"md5sum":"2298b30f04857c03d31e64ce539c1a80","name":"cp046262.zip","release":"2020-11-24T07:53:05","revision":"0","sha1sum":"9e2127c88c3d08bb5f8425c729ea6d564b6a703a","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec34a24f7b","20a6e8e4-bf33-4c71-a6bf-d9ec50f64a40","20a6e8e4-bf33-4c71-a6bf-d9ec0427da2e"],"type_of_change":"1","version":"2020.11.11","vib_list":[{"name":"nmlx4-en","version":"3.17.70.1-1OEM.670.0.0.8169922"},{"name":"nmlx4-rdma","version":"3.17.70.1-1OEM.670.0.0.8169922"},{"name":"nmlx4-core","version":"3.17.70.1-1OEM.670.0.0.8169922"}]}],"id":{"product":"5174bf3a7a274551a9858fbcf75b37fb","version":"b26f87fc452c4998972983352fad588a"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Remote Online:&nbsp;</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the HPE USB Key Creator Utility.&nbsp;</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux .</li>\n\t<li>cd /SPP20xxxxx/ and launch SUM&nbsp;(launch_sum.bat for Windows and ./launch_sum.sh for Linux).</li>\n\t<li>Select &quot;Baseline Library&quot; and wait for the Baseline inventory to complete.</li>\n\t<li>Select &quot;Nodes&quot; from the &quot;Smart Update Manager x.x.x&quot; drop down.</li>\n\t<li>Click, &quot;Add Node&quot;.\n\t<ul>\n\t\t<li>If adding a Gen9 server,\n\t\t<ul>\n\t\t\t<li>Provide IP address of the ESXi host.</li>\n\t\t\t<li>Enter&nbsp;the ESXi host credentials (root or administrator username and password)&nbsp;</li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>If adding a Gen10 and above server,\n\t\t<ul>\n\t\t\t<li>Provide iLO IP address of the ESXi host server.</li>\n\t\t\t<li>Enter the iLO credentials of the ESXi host server.</li>\n\t\t</ul>\n\t\t</li>\n\t</ul>\n\t</li>\n\t<li>Follow&nbsp;Smart Update Manager Steps and complete the driver update.&nbsp;</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware VUM or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands.</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"nmlx4_en driver component for VMware ESXi 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"1003","subdev":"1777","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1003103c1777","type":"pci","ven":"15B3"},{"dev":"1003","subdev":"18CF","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1003103c18cf","type":"pci","ven":"15B3"},{"dev":"1003","subdev":"18D6","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1003103c18d6","type":"pci","ven":"15B3"},{"dev":"1003","subdev":"18CD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1003103c18cd","type":"pci","ven":"15B3"},{"dev":"1003","subdev":"18CE","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1003103c18ce","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-11T12:10:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Changes and New features in version 3.17.70.1:</strong></p>\n\n<ul>\n\t<li>Adapter card&rsquo;s PSID is now displayed in the Privstats (Private statistics).</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>No Fixes are included in version 3.17.70.1:</strong></p>\n"},{"curr_enhancements_x_late":"<p><strong>Changes and New features in version 3.17.70.1:</strong></p>\n\n<ul>\n\t<li>Adapter card&rsquo;s PSID is now displayed in the Privstats (Private statistics).</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"nmlx4-en:3.17.70.1-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"nmlx4-rdma:3.17.70.1-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"nmlx4-core:3.17.70.1-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300032","languages":[{"lang":"fr","x_late":"Pilote - Gestion du système"},{"lang":"en","x_late":"Driver - System Management"},{"lang":"cn","x_late":"驱动程序 - 系统管理"},{"lang":"tw","x_late":"驅動程式 ─ 系統管理"},{"lang":"de","x_late":"Treiber - Systemverwaltung"},{"lang":"ko","x_late":"드라이버 - 시스템 관리"},{"lang":"it","x_late":"Driver - Gestione sistema"},{"lang":"ja","x_late":"ドライバ - システム マネジメント"},{"lang":"es","x_late":"Controlador - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"This component installs driverless INFs to identify various chipset devices."},{"lang":"ja","x_late":"このコンポーネントは、各種のチップセットデバイスを認識するための、ドライバーなしのINFをインストールします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"cn","x_late":"服务器选项"},{"lang":"ja","x_late":"サーバ オプション"}]}],"documentation":[],"files":[{"bytes":"607888","datemodified":"2019-09-26T01:32:14","file_list":["broadwell-de.cat","Broadwell-DESystem.inf","cp040885.xml","cpqsetup.exe","haswelle.cat","HaswellESystem.inf","hpgen9.dll","hpgen9inst.dll","lynxpoint.cat","LynxPointSystem.inf","null_heci.cat","NULL_HECISystem.inf","sunrisepoint-h.cat","SunrisePoint-HSystem.inf","wellsburg.cat","WellsburgSystem.inf"],"md5sum":"8895eb15a08318f8e5d9723520f39936","name":"cp040885.exe","release":"2019-09-26T01:31:02","revision":"0","sha1sum":"3776ba9c606a98180769c67cb23d02dd69cf9393","size":"593KB","target_guids":[],"type_of_change":"0","version":"10.1.17969.8134"}],"id":{"product":"fcc983919bfc411fa0536a632fac1e38","version":"cb8d45c15706411e8416dae1af18c4a0"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.\n<p>From that drive and directory, execute the downloaded file. \n<p>Click the \"Install\" button to proceed with the installation."},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。 ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。\n<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。 \n<p>[インストール]ボタンをクリックして、インストールを開始します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE ProLiant Gen9 Chipset Identifier for Windows Server 2012 R2 to Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_devices":[{"dev":"A123","subdev":"8165","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"A123","subdev":"7270","subven":"8086","target_guid":"","type":"pci","ven":"8086"},{"dev":"8D22","subdev":"8030","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"8D22","subdev":"21EB","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"6F20","subdev":"21EA","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"6F20","subdev":"18A8","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"2F20","subdev":"0000","subven":"8086","target_guid":"","type":"pci","ven":"8086"},{"dev":"2F20","subdev":"21EA","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"2F20","subdev":"18A8","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"6F28","subdev":"21EA","subven":"103C","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows 8.1 (64-bit)","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-12-18T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Add support for Windows Server 2019.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Updated to match the latest version available from Intel for the devices supported by this component.</li>\n\t<li>Removed Windows Server 2012 to align operating system support with the production Service Pack for ProLiant.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"}],"sw_keys":[{"name":"hpgen9.dll","sw_key_expectedpath":"%ProgramFiles%\\Hewlett-Packard\\HPGEN9"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWRTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57525448","Version":"HPD2"},{"DeviceName":"MB012000JWRTF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57525446","Version":"HPD2"},{"DeviceName":"MB010000JWRTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a57525445","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB014000JWRTH, MB012000JWRTF and MB010000JWRTE "},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB014000JWRTH、MB012000JWRTFおよびMB010000JWRTE "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB014000JWRTH, MB012000JWRTF and MB010000JWRTE&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None&nbsp;</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5940752","datemodified":"2021-07-23T06:00:45","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-6.1/CP048143.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-6.1/SMOBULABPSD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048143.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048143.scexe"],"md5sum":"bce3dbcd5810c5735febd919feee45da","name":"firmware-hdd-10385ef3e6-HPD2-6.1.x86_64.rpm","release":"2021-07-23T05:49:04","revision":"0","sha1sum":"466281fa21d3298e0e4863e866caa27661905187","size":"5MB","target_guids":["4d2340a5-3042-3431-3030-304a57525448","4d2340a5-3042-3231-3030-304a57525446","4d2340a5-3042-3031-3030-304a57525445"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"1d54c8dcf99741aabe78b8a4e54d84f8","version":"31604d7d8a3a4bad85711468f220af8f"},"installation":{"command":"CP041452.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB014000JWRTH, MB012000JWRTF and MB010000JWRTE Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB014000JWRTH、MB012000JWRTFおよびMB010000JWRTE ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB014000JWRTH","target_guid":"4d2340a5-3042-3431-3030-304a57525448","type":"sas"},{"id":"MB012000JWRTF","target_guid":"4d2340a5-3042-3231-3030-304a57525446","type":"sas"},{"id":"MB010000JWRTE","target_guid":"4d2340a5-3042-3031-3030-304a57525445","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-26T18:19:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB014000JWRTH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB010000JWRTE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB012000JWRTF","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VR000150GWEPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDMHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3135-304757455050","Version":"HPG1"},{"DeviceName":"VR000480GWEPR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDMHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3438-304757455052","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VR000150GWEPP and VR000480GWEPR"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VR000150GWEPP and VR000480GWEPR Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Fixes a timing issue which can cause the drive to become non-functional.</li>\n\t<li>Fixes VPD Log D0h reported drive Sanitize times.&nbsp;</li>\n\t<li>Adds support for Security Log Page BBh.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"15854514","datemodified":"2021-08-27T11:25:37","file_list":["/CP048424_BUILD_3.data","/CP048424.vmexe","/CP048424.vmexe64","/CP048424.vmfile","/CP048424_VMw.zip","/CP048424.xml","/payload.json","/CP048424_VMw.zip/index.xml","/CP048424_VMw.zip/vendor-index.xml","/CP048424_VMw.zip/metadata.zip","/CP048424_VMw.zip/vib20/CP048424/HPE_bootbank_CP048424_HPG1.3-7.0.0.15843807.vib","/CP048424_VMw.zip/metadata.zip/vendor-index.xml","/CP048424_VMw.zip/metadata.zip/vmware.xml","/CP048424_VMw.zip/metadata.zip/vibs/CP048424--5963524205731614587.xml","/CP048424_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048424_HPG1.3-7.0.0.15843807.xml"],"md5sum":"5c9d0bb220ea106a1385a641425f4472","name":"CP048424.zip","release":"2021-08-27T11:19:59","revision":"0","sha1sum":"d7f17e6f79cab654135515af2e8819b53c25d5e5","size":"15MB","target_guids":["562340a5-3052-3030-3135-304757455050","562340a5-3052-3030-3438-304757455052"],"type_of_change":"2","version":"HPG1","vib_list":[{"name":"CP048424","version":"HPG1.3-7.0.0.15843807"}]}],"id":{"product":"dbdc578953024bf9bb26afb2d6d4cd6a","version":"32c5eceb0f6f4d90a79c85ba7c1de19c"},"installation":{"command":"CP040667.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VR000150GWEPP and VR000480GWEPR Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VR000150GWEPPおよびVR000480GWEPRドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VR000480GWEPR","target_guid":"562340a5-3052-3030-3438-304757455052","type":"sata"},{"id":"VR000150GWEPP","target_guid":"562340a5-3052-3030-3135-304757455050","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-10T02:56:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Fixes a timing issue which can cause the drive to become non-functional.</li>\n\t<li>Fixes VPD Log D0h reported drive Sanitize times.</li>\n\t<li>Adds support for Security Log Page BBh.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Fixes a timing issue which can cause the drive to become non-functional.</li>\n\t<li>Fixes VPD Log D0h reported drive Sanitize times.</li>\n\t<li>Adds support for Security Log Page BBh.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VR000480GWEPR","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VR000150GWEPP","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]},{"key":"7800374","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"en","x_late":"This package contains the kit to provide support for Smart SAN on Emulex fibre channel host bus adapters on Windows 64 bit operating systems."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1578320","datemodified":"2021-08-26T07:36:43","file_list":["cp048583.xml","cpqsetup.exe","cp_data.xml","ElxSmartSANInstaller.dll","ELXSMARTSANVer.exe","esmartsan_cfg_cn.xml","esmartsan_cfg_en.xml","esmartsan_cfg_ja.xml","get_ss_status.bat","SmartSAN_Readme.txt","smartsan_x64.exe","ss_disable.bat","ss_enable.bat"],"md5sum":"0ada9c69694527b44d29619cd490af64","name":"cp048583.exe","release":"2021-08-26T07:34:07","revision":"0","sha1sum":"0a37c945b62eb46e19caa6c86fab05f76e37894c","size":"1MB","target_guids":[],"type_of_change":"0","version":"1.0.0.1"}],"id":{"product":"045232b667f2421f83708de2d92f654e","version":"2b745718a71d4f7cbbd1ff164e6b2381"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>This is a configurable component.&nbsp; It requires a configuration file in order to enable/disable Smart SAN functionality.&nbsp; If no configuration is performed, the current Smart SAN status is stated and the execution is complete.&nbsp; No further action is taken.</p>\n\n<p>&nbsp;</p>\n\n<p>For detailed information about configurable components, see the <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00106063en_us\"><em>Smart Update Manager User Guide </em></a></p>\n\n<p>&nbsp;</p>\n\n<p><strong>Component execution outside of HPE Service Pack for Proliant</strong>:</p>\n\n<ul>\n\t<li>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</li>\n\t<li>From that drive and directory, execute the downloaded file.</li>\n\t<li>Click the &quot;Install&quot; button to proceed with the installation.</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex Smart SAN Enablement Kit for Microsoft Windows Server 2012R2/2016/2019 (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T09:15:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to version 1.0.0.1</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"ELXSMARTSANVer.exe","sw_key_expectedpath":"%systemdrive%\\StorageWorks\\Version"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for HPE Intel Gigabit Ethernet NICs running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 8で動作するHPE Intel Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"119872","datemodified":"2021-08-24T16:36:19","file_list":["./etc/depmod.d/hp-igb.conf","./etc/dracut.conf.d/hp-igb-oob.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/hp-igb","./lib/modules/4.18.0-240.el8.x86_64/extra/hp-igb/igb.ko","./usr/lib/.build-id","./usr/lib/.build-id/a3","./usr/lib/.build-id/a3/21531659316146219ef3c119b51cc12929f088","./usr/share/smartupdate/kmod-hp-igb/component.xml"],"md5sum":"35ea8ad237eb62e25c783c2ed91183a4","name":"kmod-hp-igb-6.7.2-2.rhel8u3.x86_64.rpm","release":"2021-08-24T16:23:08","revision":"0","sha1sum":"f75b99d9bee5850408cdcc4a7dd09e4f75575f41","size":"117KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf5d54211"],"type_of_change":"0","version":"6.7.2-2"},{"bytes":"120106","datemodified":"2021-08-24T16:37:28","file_list":["./etc/depmod.d/hp-igb.conf","./etc/dracut.conf.d/hp-igb-oob.conf","./lib/modules/4.18.0-305.el8.x86_64","./lib/modules/4.18.0-305.el8.x86_64/extra","./lib/modules/4.18.0-305.el8.x86_64/extra/hp-igb","./lib/modules/4.18.0-305.el8.x86_64/extra/hp-igb/igb.ko","./usr/lib/.build-id","./usr/lib/.build-id/a2","./usr/lib/.build-id/a2/7cb7d4b986e9ae870979add1e97687f8f8fa66","./usr/share/smartupdate/kmod-hp-igb/component.xml"],"md5sum":"20e8e32092bd41f905e228b91153d082","name":"kmod-hp-igb-6.7.2-2.rhel8u4.x86_64.rpm","release":"2021-08-24T16:23:08","revision":"0","sha1sum":"d2dc2212138d2d1716516d40cc1269a17148374c","size":"117KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf5d54211"],"type_of_change":"0","version":"6.7.2-2"}],"id":{"product":"eb361011be5348dc81ccf25ec5c94210","version":"8f14315964454676a055cbcde7aa419f"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Intel igb Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE Intel igbドライバー for Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1523","subdev":"1989","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1523103c1989","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00FF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1521159000ff","type":"pci","ven":"8086"},{"dev":"1521","subdev":"337F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c337f","type":"pci","ven":"8086"},{"dev":"1521","subdev":"339E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c339e","type":"pci","ven":"8086"},{"dev":"1521","subdev":"17D1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c17d1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"3380","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-1521103c3380","type":"pci","ven":"8086"},{"dev":"1521","subdev":"8157","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c8157","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00A3","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a3","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>This product now support HPE Intel Online Firmware Upgrade Utility for Linux x86_64, version (or later) to update firmware</li>\n\t<li>This product now supports Red Hat Enterprise Linux 8 update 2 and Red Hat Enterprise Linux 8 update 3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>This product now supports Linux Firmware upgrade utility v.1.22.5</li>\n\t<li>This product now supports Red Hat Enterprise Linux 8 update 4</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"kmod-hp-igb","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-igb","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-igb","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-igb","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C339D","Version":"7.18.82"},{"DeviceName":"HPE Ethernet 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C18D3","Version":"7.18.82"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C1930","Version":"7.18.82"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C193A","Version":"7.18.82"},{"DeviceName":"HPE FlexFabric 10Gb 4-port 536FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-16A1159000EC","Version":"7.18.82"},{"DeviceName":"HPE NPAR 10Gb QP 536FLR-T","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-16A4159000EC","Version":"7.18.82"},{"DeviceName":"HPE StoreFabric CN1100R 10GBASE-T Dual Port Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-168E15908148","Version":"7.18.82"},{"DeviceName":"HPE StoreFabric CN1100R Dual Port Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C1931","Version":"7.18.82"},{"DeviceName":"HP NPAR 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C339D","Version":"7.18.82"},{"DeviceName":"HP NPAR 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C18D3","Version":"7.18.82"},{"DeviceName":"HP NPAR 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C193A","Version":"7.18.82"},{"DeviceName":"HP NPAR 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C1930","Version":"7.18.82"},{"DeviceName":"HP NPAR CN1100R Dual Port Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C1931","Version":"7.18.82"},{"DeviceName":"HPE NPAR 10Gb DP CN1100R-T","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16AE15908148","Version":"7.18.82"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic NX2 Gigabit Ethernet NICs Boot code, PXE, UEFI, NCSI, iSCSI, FCoE, CCM and L2 code running under VMware vSphere 6.5, 6.7, and 7.0."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"22964966","datemodified":"2021-08-12T10:31:26","file_list":["/CP046935_BUILD_22.data","/CP046935.vmexe","/CP046935.vmexe64","/CP046935.vmfile","/CP046935_VMw.zip","/CP046935.xml","/payload.json","/CP046935_VMw.zip/index.xml","/CP046935_VMw.zip/vendor-index.xml","/CP046935_VMw.zip/metadata.zip","/CP046935_VMw.zip/vib20/CP046935/HPE_bootbank_CP046935_1.29.3.22-7.0.0.15843807.vib","/CP046935_VMw.zip/metadata.zip/vendor-index.xml","/CP046935_VMw.zip/metadata.zip/vmware.xml","/CP046935_VMw.zip/metadata.zip/vibs/CP046935-589459308249466695.xml","/CP046935_VMw.zip/metadata.zip/bulletins/Smart-Component-CP046935_1.29.3.22-7.0.0.15843807.xml"],"md5sum":"a9861feae8d7f73dd7ab0af04ca8687b","name":"CP046935.zip","release":"2021-08-12T10:27:08","revision":"0","sha1sum":"0397d0223fa2f8c7028ac3528924a46d0002acb8","size":"21MB","target_guids":["a6b1a447-382a-5a4f-14E4-168E103C339D","a6b1a447-382a-5a4f-14E4-168E103C18D3","a6b1a447-382a-5a4f-14E4-168E103C1930","a6b1a447-382a-5a4f-14E4-168E103C193A","a6b1a447-382a-5a4f-1077-16A1159000EC","a6b1a447-382a-5a4f-1077-16A4159000EC","a6b1a447-382a-5a4f-14E4-168E15908148","a6b1a447-382a-5a4f-14E4-168E103C1931","a6b1a447-382a-5a4f-14E4-16AE103C339D","a6b1a447-382a-5a4f-14E4-16AE103C18D3","a6b1a447-382a-5a4f-14E4-16AE103C193A","a6b1a447-382a-5a4f-14E4-16AE103C1930","a6b1a447-382a-5a4f-14E4-16AE103C1931","a6b1a447-382a-5a4f-14E4-16AE15908148"],"type_of_change":"1","version":"1.29.3","vib_list":[{"name":"CP046935","version":"1.29.3.22-7.0.0.15843807"}]}],"id":{"product":"03d55b6f216746b88ddef311b0a8c1f9","version":"5c36a010670f468aaf3caaa7c37af4d2"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Manual installation instructions:</p>\n\n<ol>\n\t<li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li>\n\t<li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li>\n\t<li>Unzip the CPxxxxxx.zip file.</li>\n\t<li>Install the VMware component.\n\t<ul>\n\t\t<li>a. For ESXi 7.0 targets: esxcli &nbsp;software component apply &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply &ndash;d /tmp/CPxxxxxx_VMware.zip&quot;)</li>\n\t\t<li>b. For ESXi 6.x targets: esxcli software vib install &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install &ndash;d /tmp/CPxxxxxx_VMw.zip&quot;)</li>\n\t</ul>\n\t</li>\n\t<li>.Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li>\n\t<li>Execute the component with the command set options &nbsp;s, -f, -e, -g, &nbsp;etc. if required. When execution is complete the flash engine will have performed the flash operation as directed.</li>\n\t<li>Clean up the Smart Component:\n\t<ul>\n\t\t<li>a. Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li>\n\t\t<li>b. To clean up the Smart Component:\n\t\t<ul>\n\t\t\t<li>i.For ESXi 7.0 targets: esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t\t\t<li>ii.For ESXi 6.x targets: esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>c.Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li>\n\t</ul>\n\t</li>\n\t<li>If reboot is required to complete the firmware installation, reboot your system.</li>\n</ol>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.&nbsp;</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 VMware 的 HPE QLogic NX2 上韌體升級公用程式"},{"lang":"en","x_late":"HPE QLogic NX2 Online Firmware Upgrade Utility for VMware"},{"lang":"ko","x_late":"VMware용 HPE QLogic NX2 온라인 펌웨어 업그레이드 유틸리티"},{"lang":"cn","x_late":"VMware版HPE QLogic NX2在线固件升级实用程序"},{"lang":"ja","x_late":"HPE QLogic NX2オンライン ファームウェアアップグレードユーティリティ for VMware"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"168E","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c339d","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c18d3","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1930","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c193a","type":"pci","ven":"14E4"},{"dev":"16A1","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a1159000ec","type":"pci","ven":"1077"},{"dev":"16A4","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a4159000ec","type":"pci","ven":"1077"},{"dev":"168E","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-168e15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1931","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c339d","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c193a","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1930","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1931","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ae15908148","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li><strong>This product addressed the firmware update failure problem which may cause NIC FW corruption.</strong></li>\n\t<li><strong>This product addressed the firmware update failure problem while the platform secure boot being enabled.</strong></li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>This products enhances the mechanism that memory usage when more than one adapters</li>\n\t<li>This product now supports VMware ESXi 7.0 u3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"QLOGIC_NX2","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG1800JEMDB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBT2D5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3830-304a454d4442","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: EG1800JEMDB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online HDD/SSD Flash Component for Windows (x64) - EG1800JEMDB Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp;&nbsp; </strong>None</p>\n"}],"files":[{"bytes":"3775912","datemodified":"2021-07-24T06:10:36","file_list":["cp048508.xml","cpqsetup.exe","payload.json","setup.dll","STHBT2D5.rel"],"md5sum":"7dc8590852dcde6c328cc5224ecf61fb","name":"cp048508.exe","release":"2021-07-24T06:03:09","revision":"0","sha1sum":"146b9422fd418969ddc34f3d3adb43c67495a033","size":"3MB","target_guids":["002340a5-4500-3147-3830-304a454d4442"],"type_of_change":"1","version":"HPD5"}],"id":{"product":"0099c8dbd23e4805b57e681e858e79b9","version":"5977465dbf4f4898a1dee5ddcef30253"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG1800JEMDB Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EG1800JEMDBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG1800JEMDB","target_guid":"002340a5-4500-3147-3830-304a454d4442","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T08:31:22","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG1800JEMDB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for HPE QLogic NX2 10/20 GbE Multifunction Adapters running under VMware vSphere 7.0."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains the following drivers:</p>\n\n<ul>\n\t<li>qfle3, version 1.4.17.0</li>\n\t<li>qcnic, version 2.0.59.0</li>\n\t<li>qfle3i, version 2.1.8.0</li>\n\t<li>qfle3f, version 2.1.25.0</li>\n</ul>\n"}],"files":[{"bytes":"1512785","datemodified":"2021-08-11T13:59:33","file_list":["/cp047117.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip/index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip/metadata.zip","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip/vib20/qcnic/QLC_bootbank_qcnic_2.0.59.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip/vib20/qfle3i/QLC_bootbank_qfle3i_2.1.8.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip/vib20/qfle3f/QLC_bootbank_qfle3f_2.1.25.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip/vib20/qfle3/QLC_bootbank_qfle3_1.4.17.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip/metadata.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip/metadata.zip/vmware.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip/metadata.zip/vibs/qfle3-1191248098602857359.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip/metadata.zip/vibs/qfle3i--558247773911429780.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip/metadata.zip/vibs/qfle3f--371781071515599867.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip/metadata.zip/vibs/qcnic-3768180827600800407.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip/metadata.zip/bulletins/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807.xml"],"md5sum":"86a11c7f39d81c49603838e2a5fac06b","name":"cp047117.zip","release":"2021-08-11T13:56:16","revision":"0","sha1sum":"bdf2f2f6d258702f7c0e8addbc6a2c1bb4d27470","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eca261a1a0","20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","20a6e8e4-bf33-4c71-a6bf-d9ec7339bbbe","20a6e8e4-bf33-4c71-a6bf-d9ece189dca8","20a6e8e4-bf33-4c71-a6bf-d9ecbba24fc7"],"type_of_change":"0","version":"2021.09.04","vib_list":[{"name":"qcnic","version":"2.0.59.0-1OEM.700.1.0.15843807"},{"name":"qfle3i","version":"2.1.8.0-1OEM.700.1.0.15843807"},{"name":"qfle3f","version":"2.1.25.0-1OEM.700.1.0.15843807"},{"name":"qfle3","version":"1.4.17.0-1OEM.700.1.0.15843807"}]}],"id":{"product":"38b83226aeb64480960e8558ac22cab4","version":"0ad463467f844eeca756216a1bd76d09"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバーにUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic NX2 10/20 GbE Multifunction Driver for VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"168E","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c339d","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c18d3","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1930","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c193a","type":"pci","ven":"14E4"},{"dev":"16A1","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a1159000ec","type":"pci","ven":"1077"},{"dev":"16AF","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c339d","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c18d3","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c193a","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1930","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1931","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c339d","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c193a","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1930","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16ad159000ec","type":"pci","ven":"1077"},{"dev":"16A4","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a4159000ec","type":"pci","ven":"1077"},{"dev":"16AE","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1931","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16af15908148","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ae15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-168e15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1931","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product addresses an issue about 536FLR-T adapter latency/link down when running a LiveCoreDump on vCenter.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>This products enhances the mechanism that collation of data log.</li>\n\t<li>This product now supports ESXi 7.0 U3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"qfle3f:2.1.25.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qfle3:1.4.17.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qfle3i:2.1.8.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"MRVL-E3-Ethernet-iSCSI-FCoE:3.0.143.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver.component:vmware:zip"},{"name":"qcnic:2.0.59.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO002000KWVVC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3230-3030-304b57565643","Version":"4ICRHPK3"},{"DeviceName":"VO004000KWVUR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3430-3030-304b57565552","Version":"4ICRHPK3"},{"DeviceName":"MO001600KWVUU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b57565555","Version":"4ICRHPK3"},{"DeviceName":"MO003200KWVUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b57565556","Version":"4ICRHPK3"},{"DeviceName":"MO006400KWVVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b57565641","Version":"4ICRHPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;NVMe SSD&nbsp;Flash Component for Windows&nbsp;(x64) - &nbsp;VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp;&nbsp; 4ICRHPK3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to 4ICRHPK3 that may result in SSD failure starting at 4,700 hours of operation, neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us\" style=\"color: blue; text-decoration: underline;\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us</a></li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3251592","datemodified":"2021-07-24T10:35:34","file_list":["4ICRHPK3.rel","cp048693.xml","cpqsetup.exe","payload.json","setup.dll"],"md5sum":"c0198497cd2faefd5ec0e0a7419682c9","name":"cp048693.exe","release":"2021-07-24T10:28:04","revision":"0","sha1sum":"de93a9c85e6f4ba6499445b372132ed24966f902","size":"3MB","target_guids":["562340a5-304f-3230-3030-304b57565643","562340a5-304f-3430-3030-304b57565552","4d2340a5-304f-3130-3630-304b57565555","4d2340a5-304f-3330-3230-304b57565556","4d2340a5-304f-3630-3430-304b57565641"],"type_of_change":"2","version":"4ICRHPK3"}],"id":{"product":"840d26617d5744de973393a116bf720d","version":"283d383d67b2453da44789b3da9f7829"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - VO002000KWVVC、VO004000KWVUR、MO001600KWVUU、MO003200KWVUV、およびMO006400KWVVAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MO006400KWVVA","target_guid":"4d2340a5-304f-3630-3430-304b57565641","type":"nvme"},{"id":"VO004000KWVUR","target_guid":"562340a5-304f-3430-3030-304b57565552","type":"nvme"},{"id":"MO003200KWVUV","target_guid":"4d2340a5-304f-3330-3230-304b57565556","type":"nvme"},{"id":"VO002000KWVVC","target_guid":"562340a5-304f-3230-3030-304b57565643","type":"nvme"},{"id":"MO001600KWVUU","target_guid":"4d2340a5-304f-3130-3630-304b57565555","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-17T11:26:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Fixed issues described in Customer Bulletin&nbsp;at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111900en_us.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to 4ICRHPK3 that may result in SSD failure starting at 4,700 hours of operation, neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us\" style=\"color: blue; text-decoration: underline;\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MO001600KWVUU","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO002000KWVVC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO004000KWVUR","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO006400KWVVA","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO003200KWVUV","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 1Gb 2-port 363i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1523103C1989","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37CE15900215","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900216","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366i Communication Board","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521159000FF","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 369i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900247","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C337F","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C3380","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 560FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-10FB103C17D0","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C339E","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C17D1","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C8157","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 560SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-10FB103C17D3","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FC","Version":"10.54.7"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D2","Version":"10.54.4"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FD","Version":"10.54.7"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D1","Version":"10.54.4"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D315900219","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900217","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D215900218","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 561T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1528103C211A","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 561FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1528103C192D","Version":"1.2836.0"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE ProLiant Intel Gigabit Ethernet NICs ROM images running under running under VMware vSphere 6.5, 6.7 and 7.0"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"25393070","datemodified":"2021-08-28T00:29:41","file_list":["/CP047025_BUILD_43.data","/CP047025.vmexe","/CP047025.vmexe64","/CP047025.vmfile","/CP047025_VMw.zip","/CP047025.xml","/payload.json","/CP047025_VMw.zip/index.xml","/CP047025_VMw.zip/vendor-index.xml","/CP047025_VMw.zip/metadata.zip","/CP047025_VMw.zip/vib20/CP047025/HPE_bootbank_CP047025_3.15.5.43-7.0.0.15843807.vib","/CP047025_VMw.zip/metadata.zip/vendor-index.xml","/CP047025_VMw.zip/metadata.zip/vmware.xml","/CP047025_VMw.zip/metadata.zip/vibs/CP047025-4133156345354741548.xml","/CP047025_VMw.zip/metadata.zip/bulletins/Smart-Component-CP047025_3.15.5.43-7.0.0.15843807.xml"],"md5sum":"184632de6965ad8dc6c634ff222b8918","name":"CP047025.zip","release":"2021-08-28T00:25:23","revision":"0","sha1sum":"8c60c6a26ca377411bd2fb6ed28460e1ca7db3d3","size":"24MB","target_guids":["a6b1a447-382a-5a4f-8086-1523103C1989","a6b1a447-382a-5a4f-8086-37CE15900215","a6b1a447-382a-5a4f-8086-37D115900216","a6b1a447-382a-5a4f-8086-1521159000FF","a6b1a447-382a-5a4f-8086-37D115900247","a6b1a447-382a-5a4f-8086-1521103C337F","a6b1a447-382a-5a4f-8086-1521103C3380","a6b1a447-382a-5a4f-8086-10FB103C17D0","a6b1a447-382a-5a4f-8086-1521103C339E","a6b1a447-382a-5a4f-8086-1521103C17D1","a6b1a447-382a-5a4f-8086-1521103C8157","a6b1a447-382a-5a4f-8086-10FB103C17D3","a6b1a447-382a-5a4f-8086-1572103C22FC","a6b1a447-382a-5a4f-8086-1563159000D2","a6b1a447-382a-5a4f-8086-1572103C22FD","a6b1a447-382a-5a4f-8086-1563159000D1","a6b1a447-382a-5a4f-8086-37D315900219","a6b1a447-382a-5a4f-8086-37D115900217","a6b1a447-382a-5a4f-8086-37D215900218","a6b1a447-382a-5a4f-8086-1528103C211A","a6b1a447-382a-5a4f-8086-1528103C192D"],"type_of_change":"0","version":"3.15.5","vib_list":[{"name":"CP047025","version":"3.15.5.43-7.0.0.15843807"}]}],"id":{"product":"79ba405b8c19425aa9a14902b672b652","version":"2d5b737d81b14c28859d35fd1def27ba"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Manual installation instructions:</p>\n\n<ol>\n\t<li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li>\n\t<li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li>\n\t<li>Unzip the CPxxxxxx.zip file.</li>\n\t<li>Install the VMware component.\n\t<ul>\n\t\t<li>a. For ESXi 7.0 targets: esxcli &nbsp;software component apply &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply &ndash;d /tmp/CPxxxxxx_VMware.zip&quot;)</li>\n\t\t<li>b. For ESXi 6.x targets: esxcli software vib install &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install &ndash;d /tmp/CPxxxxxx_VMw.zip&quot;)</li>\n\t</ul>\n\t</li>\n\t<li>.Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li>\n\t<li>Execute the component with the command set options &nbsp;s, -f, -e, -g, &nbsp;etc. if required. When execution is complete the flash engine will have performed the flash operation as directed.</li>\n\t<li>Clean up the Smart Component:\n\t<ul>\n\t\t<li>a. Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li>\n\t\t<li>b. To clean up the Smart Component:\n\t\t<ul>\n\t\t\t<li>i.For ESXi 7.0 targets: esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t\t\t<li>ii.For ESXi 6.x targets: esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>c.Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li>\n\t</ul>\n\t</li>\n\t<li>If reboot is required to complete the firmware installation, reboot your system.</li>\n</ol>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong><em>Additional Information:</em></strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed. For more information about downgrade limitation, refer to the following Customer advisory:&nbsp;<br />\n\thttps://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00069764en_us</li>\n\t<li>AC Power Cycle is required after firmware installation for updates&nbsp;to take effect for the following network adapters:<br />\n\tHPE Ethernet 1Gb 2-port 368i Adapter<br />\n\tHPE Ethernet 1Gb 2-port 369i Adapter<br />\n\tHPE Ethernet 1Gb 2-port 368FLR-MMT Adapter<br />\n\tHPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter<br />\n\tHPE Ethernet 10Gb 2-port 568FLR-MMT Adapter</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 VMware 的 HPE Intel 線上韌體升級公用程式"},{"lang":"en","x_late":"HPE Intel Online Firmware Upgrade Utility for VMware"},{"lang":"ko","x_late":"VMware용 HPE Intel 온라인 펌웨어 업그레이드 유틸리티"},{"lang":"cn","x_late":"VMware版HPE Intel在线固件升级实用程序"},{"lang":"ja","x_late":"HPE Intelオンライン ファームウェアアップグレードユーティリティ for VMware"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"1523","subdev":"1989","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1523103c1989","type":"pci","ven":"8086"},{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00FF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1521159000ff","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"1521","subdev":"337F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c337f","type":"pci","ven":"8086"},{"dev":"1521","subdev":"3380","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-1521103c3380","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"1521","subdev":"339E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c339e","type":"pci","ven":"8086"},{"dev":"1521","subdev":"17D1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c17d1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"8157","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c8157","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c211a","type":"pci","ven":"8086"},{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c192d","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product addresses an issue where Systems Insight Display (SID) modul is green when there&#39;s no Network connection.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports VMware ESXi 7.0 u3</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"}],"sw_keys":[{"name":"INTEL","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000GEQNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPFCGB.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304745514e48","Version":"HPGB"},{"DeviceName":"MB6000GEQNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPFCGB.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745514e4b","Version":"HPGB"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB4000GEQNH and MB6000GEQNK"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MB4000GEQNHおよびMB6000GEQNK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB4000GEQNH and MB6000GEQNK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGB<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG7</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.&nbsp; This issue was found during supplier ongoing reliability testing.</li>\n\t<li>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"17601926","datemodified":"2021-08-26T19:49:32","file_list":["/CP048366_BUILD_2.data","/CP048366.vmexe","/CP048366.vmexe64","/CP048366.vmfile","/CP048366_VMw.zip","/CP048366.xml","/payload.json","/CP048366_VMw.zip/index.xml","/CP048366_VMw.zip/vendor-index.xml","/CP048366_VMw.zip/metadata.zip","/CP048366_VMw.zip/vib20/CP048366/HPE_bootbank_CP048366_HPGB.2-7.0.0.15843807.vib","/CP048366_VMw.zip/metadata.zip/vendor-index.xml","/CP048366_VMw.zip/metadata.zip/vmware.xml","/CP048366_VMw.zip/metadata.zip/vibs/CP048366--4442060161600011718.xml","/CP048366_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048366_HPGB.2-7.0.0.15843807.xml"],"md5sum":"311f19cfe8c73ad36ab3b6edaa340cd2","name":"CP048366.zip","release":"2021-08-26T19:43:06","revision":"0","sha1sum":"d9b83ac77b0de8bd95af07ebb8147faffb6cca1f","size":"16MB","target_guids":["002340a5-4d00-3442-3030-304745514e48","002340a5-4d00-3642-3030-304745514e4b"],"type_of_change":"2","version":"HPGB","vib_list":[{"name":"CP048366","version":"HPGB.2-7.0.0.15843807"}]}],"id":{"product":"6a439b96c74c406881767d161dad104f","version":"5bc6206478504fe2af895fd983130f30"},"installation":{"command":"CP039425.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB4000GEQNH and MB6000GEQNK Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB4000GEQNHおよびMB6000GEQNKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB4000GEQNH","target_guid":"002340a5-4d00-3442-3030-304745514e48","type":"sata"},{"id":"MB6000GEQNK","target_guid":"002340a5-4d00-3642-3030-304745514e4b","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-07T18:59:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was found during supplier ongoing reliability testing.</li>\n\t<li>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was found during supplier ongoing reliability testing.</li>\n\t<li>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000GEQNH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB6000GEQNK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5718760","datemodified":"2021-05-18T02:33:00","file_list":["SignedImageInstaller64.dll","U17_2.90_04_29_2021.signed.flash","cp047949.xml","cpqsetup.exe","cpqsysio64.sys"],"md5sum":"880119c38126fbef6f6d21b52c07f2a6","name":"cp047949.exe","release":"2021-05-18T02:16:10","revision":"0","sha1sum":"78a013d49b918e93b0c29b9cb14a97b6be87864d","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021"}],"id":{"product":"07347f7a083340a09fea50459ac770da","version":"afd33688b42d4843a55252cc6e00f8a5"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL580 Gen9 (U17) Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-17T02:26:05","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>Ver. 2.80_10-16-2020(B) contains updates to the firmware packaging and is functionally equivalent to ver. 2.80_10-16-2020. It is not necessary to upgrade with Revision B if a previous component revision was used to upgrade the firmware to version 2.80_10-16-2020.</p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000019 (CPUID 306F4) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"}],"sw_keys":[{"name":"U17","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for supported HPE Mellanox adapter cards."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"19088","datemodified":"2021-07-21T05:52:01","file_list":["./etc/depmod.d/kernel-mft-mlnx-mst_pci.conf","./etc/depmod.d/kernel-mft-mlnx-mst_pciconf.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/kernel-mft-mlnx","./lib/modules/3.10.0-1160.el7.x86_64/extra/kernel-mft-mlnx/mst_pci.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/kernel-mft-mlnx/mst_pciconf.ko","./usr/share/smartupdate/kmod-kernel-mft-mlnx/component.xml"],"md5sum":"6dd53481b3187caaa8810a722c5e33ef","name":"kmod-kernel-mft-mlnx-4.17.0-1.rhel7u9.x86_64.rpm","release":"2021-07-21T05:38:04","revision":"0","sha1sum":"78ea64fc7b59a35269e1e66eaabb754d36fce857","size":"18KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecca403118","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"type_of_change":"1","version":"4.17"},{"bytes":"10006573","datemodified":"2021-07-21T05:46:10","file_list":["./etc/bash_completion.d/mft/mft_base_autocomplete","./etc/bash_completion.d/mft/mft_help_to_completion.py","./etc/init.d/mst","./etc/mft/RPMS/mft","./etc/mft/mft.conf","./etc/mft/mst.conf","./usr/bin/flint","./usr/bin/flint_ext","./usr/bin/mcra","./usr/bin/mdevices_info","./usr/bin/mft_uninstall.sh","./usr/bin/minit","./usr/bin/mlxfwreset","./usr/bin/mlxfwstress","./usr/bin/mlxfwstress_ext","./usr/bin/mlxgearbox","./usr/bin/mlxpci","./usr/bin/mlxprivhost","./usr/bin/mst","./usr/bin/mst_cable","./usr/bin/mst_ib_add","./usr/bin/mstop","./usr/bin/resourcedump","./usr/bin/resourceparse","./usr/bin/stedump","./usr/share/man/man1","./usr/share/man/man1/flint.1.gz","./usr/share/man/man1/mcra.1.gz","./usr/share/man/man1/mdevices_info.1.gz","./usr/share/man/man1/minit.1.gz","./usr/share/man/man1/mlxfwreset.1.gz","./usr/share/man/man1/mst.1.gz","./usr/share/man/man1/mstop.1.gz","./usr/share/mft/fw_stress_db","./usr/share/mft/fw_stress_db/stress_types.db","./usr/share/mft/prm_dbs","./usr/share/mft/prm_dbs/hca","./usr/share/mft/prm_dbs/hca/ext","./usr/share/mft/prm_dbs/hca/ext/register_access_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.dat","./usr/share/mft/prm_dbs/switch","./usr/share/mft/prm_dbs/switch/ext","./usr/share/mft/prm_dbs/switch/ext/register_access_table.adb","./usr/share/mft/prm_dbs/switch/ext/register_access_table.dat","./usr/share/smartupdate/mft/component.xml","./etc/bash_completion.d/mft/mft_help_to_completion.pyc","./etc/bash_completion.d/mft/mft_help_to_completion.pyo"],"md5sum":"2931e6104512f3c2e7ac5757abdfbd41","name":"mft-4.17.0-106.rhel7u9.x86_64.rpm","release":"2021-07-21T05:38:04","revision":"0","sha1sum":"b3d7c0cbf94cfd521ccbec3738934cf19675ec5a","size":"9MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecca403118","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"type_of_change":"1","version":"4.17"}],"id":{"product":"7cbddfc3ba97405ea0a71d3635caace8","version":"01fda099a48542e4a051fc0b3dd2276d"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using kernel version 3.10.0-1160.el7&nbsp;or any future errata:<br />\n<br />\n<strong># rpm -Uvh kmod-kernel-mft-mlnx-4.17.0-1.rhel7u9.x86_64.rpm&nbsp;&nbsp;mft-4.17.0-64.rhel7u9.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for Red Hat Enterprise Linux 7 Update 9 (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"101f","subdev":"0012","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30012","type":"pci","ven":"15b3"},{"dev":"101f","subdev":"0007","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30007","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T18:00:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","latest_fixes_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n"},{"curr_enhancements_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","curr_fixes_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"kmod-kernel-mft-mlnx","sw_key_expectedpath":"software:rpm"},{"name":"mft","sw_key_expectedpath":"software:rpm"},{"name":"kmod-kernel-mft-mlnx","sw_key_expectedpath":"software:rpm"},{"name":"mft","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWJAN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-3047574a414e","Version":"HPG1"},{"DeviceName":"MB002000GWFWA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757465741","Version":"HPG1"},{"DeviceName":"MB004000GWFWB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757465742","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB001000GWJAN, MB002000GWFWA and MB004000GWFWB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5232121","datemodified":"2021-07-23T08:02:33","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-6.1/CP048095.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-6.1/TATCATSATAG1.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048095.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048095.scexe"],"md5sum":"234b77d0d62479e694a3150d36de943d","name":"firmware-hdd-d39e7a7e75-HPG1-6.1.x86_64.rpm","release":"2021-07-23T07:48:12","revision":"0","sha1sum":"0f066196951f95f988551292f09e9227e828b7d5","size":"4MB","target_guids":["4d2340a5-3042-3130-3030-3047574a414e","4d2340a5-3042-3230-3030-304757465741","4d2340a5-3042-3430-3030-304757465742"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"c20869f6e72044ccb4d2b142b029a1ef","version":"7798daf681e44902877c7a27f831b447"},"installation":{"command":"CP040351.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB001000GWJAN、MB002000GWFWAおよびMB004000GWFWBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB004000GWFWB","target_guid":"4d2340a5-3042-3430-3030-304757465742","type":"sata"},{"id":"MB002000GWFWA","target_guid":"4d2340a5-3042-3230-3030-304757465741","type":"sata"},{"id":"MB001000GWJAN","target_guid":"4d2340a5-3042-3130-3030-3047574a414e","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T12:20:07","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB004000GWFWB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB001000GWJAN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB002000GWFWA","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following storage controllers: Smart Array and Smart HBA H240ar, H240nr, H240, H241, H244br, P240nr, P244br, P246br, P440ar, P440, P441, P542D, P741m, P840, P840ar, and  P841"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のストレージコントローラーのファームウェアを提供します。SmartアレイおよびSmart HBA H240ar、H240nr、H240、H241、H244br、P240nr、P244br、P246br、P440ar、P440、P441、P542D、P741m、P840、P840arおよびP841"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name</strong><strong>:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for Windows (x64) - Smart Array and Smart HBA H240ar, H240nr, H240, H241, H244br, P240nr, P244br, P246br, P440ar, P440, P441, P542D, P741m, P840, P840ar, and&nbsp;P841<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;7.00<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;6.88<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;6.60(B)<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp; &nbsp; Initial release for Snap4</li>\n</ul>\n\n<p><strong>Problems Fix</strong><strong>ed:</strong></p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Known&nbsp;Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4805536","datemodified":"2019-08-08T19:27:26","file_list":["cp039995.xml","cpqsetup.exe","firmware_signed.bin.fw","setup.dll"],"md5sum":"26ea1c08bcdb8ef0547df414eafa22b9","name":"cp039995.exe","release":"2019-08-08T19:14:03","revision":"0","sha1sum":"55f024b36509b67ef995a6b1941523fa39798a6e","size":"4MB","target_guids":[],"type_of_change":"1","version":"7.00"}],"id":{"product":"abb94178152540d4b4597562d0b2a39f","version":"e72e09a823154db2bd8dc779aa2a7ff1"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Smart Array Controller Driver version 3.4.4 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec21fe94e4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"3.4.4-0","description":"HP ProLiant Smart Array Controller Driver version 3.4.4 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Smart Array Controller Driver version 3.4.6 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec21fe94e4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"3.4.6-0","description":"HP ProLiant Smart Array Controller Driver version 3.4.6 or greater is required and should be already active"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActiveIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Smart Array HPCISSS3 Controller Driver version 100.18.2.64 must not be used for firmware update.  Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfd368f11","ServerModel":["*"],"Target_guids":[],"Type":"NE","Version":"100.18.2.64","description":"HPE ProLiant Smart Array HPCISSS3 Controller Driver version 100.18.2.64 must not be used for firmware update.  Update the driver and reboot before attempting firmware update."}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><strong><a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a><strong>:</strong></strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li>\n\t<li>Run launch_sum.bat script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><strong><a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a><strong></strong></strong>から以下の手順に従ってください：</p>\n\n<ul>\n\t<li>ディレクトリ\\SPP20xxxxx\\hp\\swpackagesにアップデートに必要なファームウェアをコピーします。</li>\n\t<li>ISOのルートにあるlaunch_hpsum.batスクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows (x64) - Smart Array and Smart HBA H240ar, H240nr, H240, H241, H244br, P240nr, P244br, P246br, P440ar, P440, P441, P542D, P741m, P840, P840ar, and  P841"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Windows（x64）- SmartアレイおよびSmart HBA H240ar、H240nr、H240、H241、H244br、P240nr、P244br、P246br、P440ar、P440、P441、P542D、P741m、P840、P840arおよびP841"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_devices":[{"dev":"3239","subdev":"21c3","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c0","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c2","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21BD","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c7","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21bf","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c6","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cb","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21be","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c5","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ca","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c8","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cc","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21CD","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ce","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c1","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-06-29T18:57:16","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Fixes the following Issues</p>\n\n<ul>\n\t<li>SATA drive could stop responding&nbsp; while on HBA mode when non-NCQ commands are executed</li>\n\t<li>Controller could stop responding when upgrading due to the DDR Cache Module exceeding its limitations</li>\n\t<li>SSD Cache module could become disable while upgrading FW</li>\n\t<li>Data from the HPE Smart Drive Backplane could potentially become corrupted if a non-HPE carrier is present</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Add optimization for the iLO communication interface in order to have a more effective mechanism to check for ownership of the communication buffer</p>\n","curr_fixes_x_late":"<ul>\n\t<li>Occasionally&nbsp; the drive will not accept any IO&rsquo;s after running Sanitize command for a period of time due to the FW being out of sync with the drive during that time</li>\n\t<li>Non-HPE drives could report &ldquo;Task Set Full&rdquo; due to the drives reaching the qdepth limit during heavy workload</li>\n\t<li>Raid volume is not discovered due to a bad drive consuming two slots during hotplug</li>\n\t<li>Data could become inaccessible when upgrading from&nbsp;firmware versions prior to 4.5x</li>\n\t<li>The controller could stop responding when executing a SCSI verify command due to a CPU exception</li>\n\t<li>The system could stop communicating due to an I/O command timeout</li>\n\t<li>While on HBA mode, a drive could stop responding due to an early allocated buffer release</li>\n\t<li>A SAS drive WWN is reported inaccuratelyy due to an incorrect report causing the driver to be out of sync with the device</li>\n\t<li>If using a 4G module, the controller could stop responding due to the SSD Cache metadata exceeding its limits during a Backup</li>\n\t<li>SSD Smart Cache module become disabled due to a reduction in usable cache space</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"21be103c","sw_key_expectedpath":"firmware"},{"name":"21CD103c","sw_key_expectedpath":"firmware"},{"name":"21cb103c","sw_key_expectedpath":"firmware"},{"name":"21BD103c","sw_key_expectedpath":"firmware"},{"name":"21c6103c","sw_key_expectedpath":"firmware"},{"name":"21c1103c","sw_key_expectedpath":"firmware"},{"name":"21c5103c","sw_key_expectedpath":"firmware"},{"name":"21cc103c","sw_key_expectedpath":"firmware"},{"name":"21c2103c","sw_key_expectedpath":"firmware"},{"name":"21c8103c","sw_key_expectedpath":"firmware"},{"name":"21c3103c","sw_key_expectedpath":"firmware"},{"name":"21bf103c","sw_key_expectedpath":"firmware"},{"name":"21c7103c","sw_key_expectedpath":"firmware"},{"name":"21ca103c","sw_key_expectedpath":"firmware"},{"name":"21ce103c","sw_key_expectedpath":"firmware"},{"name":"21c0103c","sw_key_expectedpath":"firmware"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]},{"key":"7800374","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"en","x_late":"This package contains utilities and libraries to enable HPE Storage fibre channel over Ethernet array connectivity on Red Hat Enterprise Linux 7 Server for Emulex Host Bus Adapters and Mezzanine Host Bus Adapters"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1647120","datemodified":"2021-08-27T06:09:51","file_list":["./opt/broadcom/rhel7/i386/lib/libbrcmdfc.so","./opt/broadcom/rhel7/i386/lib/libbrcmdfc.so.12","./opt/broadcom/rhel7/i386/lib/libbrcmdfc.so.12.0.1329","./opt/broadcom/rhel7/i386/lib/libbrcmemsdm.so","./opt/broadcom/rhel7/i386/lib/libbrcmhbaapi.so","./opt/broadcom/rhel7/x86_64/lib64/libbrcmdfc.so","./opt/broadcom/rhel7/x86_64/lib64/libbrcmdfc.so.12","./opt/broadcom/rhel7/x86_64/lib64/libbrcmdfc.so.12.0.1329","./opt/broadcom/rhel7/x86_64/lib64/libbrcmemsdm.so","./opt/broadcom/rhel7/x86_64/lib64/libbrcmhbaapi.so","./usr/lib/libbrcmdfc.so","./usr/lib/libbrcmdfc.so.12","./usr/lib/libbrcmdfc.so.12.0.1329","./usr/lib/libbrcmemsdm.so","./usr/lib/libbrcmhbaapi.so","./usr/lib64/libbrcmdfc.so","./usr/lib64/libbrcmdfc.so.12","./usr/lib64/libbrcmdfc.so.12.0.1329","./usr/lib64/libbrcmemsdm.so","./usr/lib64/libbrcmhbaapi.so","./usr/share/smartupdate/HPE-CNA-FC-Broadcom-Enablement-Kit/component.xml"],"md5sum":"23e19ccbc03d55a07a2880c42922392c","name":"HPE-CNA-FC-Broadcom-Enablement-Kit-12.0.1339.0-1.rhel7.x86_64.rpm","release":"2021-08-27T06:06:15","revision":"0","sha1sum":"b708d12cc7138ebe7d712d59d59e868cf64e0ec4","size":"1MB","target_guids":[],"type_of_change":"1","version":"12.0.1339.0"}],"id":{"product":"61b9ab450a294ed08b783b74eb3fe4b2","version":"3b32e7e0e71244eaaa6f1e1705f994a4"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>There has been a change to the enablement kits in this release.&nbsp; They are now vendor specific kits.&nbsp;&nbsp; It is recommended that you uninstall any previous kits prior to installation of this component.<br />\n<br />\nTo uninstall the hp-fc-enablement RPM use the following command:</p>\n\n<p>&nbsp;&nbsp; # rpm -e hp-fc-enablement-&lt;version&gt;.noarch.rpm<br />\n<br />\nTo install the hp-CNA-fc-enablement RPM use the following command:</p>\n\n<p>&nbsp;&nbsp; # rpm -ivh HP-CNA-FC-Broadcom-Enablement-Kit-&lt;version&gt;.&lt;OS&gt;.&lt;architecture&gt;.rpm<br />\n<br />\nThis version of the enablement kit does not provide the additional functionality of rebuilding the ram disk or setting driver parameters as the previous versions had done.&nbsp; Please refer to the &ldquo;Additional setup&rdquo; section of the Native Linux Device-Mapper Multipath for HPE StorageWorks Arrays reference guide for instructions on how to perform these functions.&nbsp; The reference guide is available at the following link:<br />\n&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; <a href=\"http://www.hpe.com/storage/spock/\">http://www.hpe.com/storage/spock/</a><br />\n&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex(BRCM) Fibre Channel Over Ethernet Enablement Kit for Host Bus Adapters and Mezzanine Host Bus Adapters for Red Hat Enterprise Linux 7 Server"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T11:01:08","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated EK version to 12.0.1339.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"}],"sw_keys":[{"name":"HPE-CNA-FC-Broadcom-Enablement-Kit","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This package updates the I/O module firmware on HPE D3600, D3700, D3610 and D3710 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"16924110","datemodified":"2021-07-06T08:01:30","file_list":["/CP048696_BUILD_2.data","/CP048696.vmcfg","/CP048696.vmexe","/CP048696.vmexe64","/CP048696.vmfile","/CP048696_VMw.zip","/CP048696.xml","/payload.json","/CP048696_VMw.zip/index.xml","/CP048696_VMw.zip/vendor-index.xml","/CP048696_VMw.zip/metadata.zip","/CP048696_VMw.zip/vib20/CP048696/HPE_bootbank_CP048696_5.04.2-7.0.0.15843807.vib","/CP048696_VMw.zip/metadata.zip/vendor-index.xml","/CP048696_VMw.zip/metadata.zip/vmware.xml","/CP048696_VMw.zip/metadata.zip/vibs/CP048696--8041700259164112.xml","/CP048696_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048696_5.04.2-7.0.0.15843807.xml"],"md5sum":"2e620f3224849e1ffa525e75cc38d252","name":"CP048696.zip","release":"2021-07-06T07:57:04","revision":"0","sha1sum":"6b5d55e0e5660e77bfcdbb4efa402c3e04f09879","size":"16MB","target_guids":[],"type_of_change":"1","version":"5.04","vib_list":[{"name":"CP048696","version":"5.04.2-7.0.0.15843807"}]}],"id":{"product":"7aa1933c093749bcbf4d95d4469c5a99","version":"3deb45cb2fd04398ab9371166a7bd404"},"installation":{"command":"setup","command_params":"-t D3600 -t D3610 -t D3700 -t D3710 -v 5.04 -i Reveille-Release-5.04-build-000.bin -l D3000.log","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":900,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>VMWare Smart Component Installation Instructions:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root (You must be root in order to apply the ROM update).</li>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Unzip the Smart Component with unzip CP0xxxxx.zip command.</li>\n\t<li>From the same directory, execute the Smart Component. For example: ./CP0xxxxx.vmexe.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p><strong>NOTES:</strong></p>\n\n<p>OPTIONS for in band enclosure flash</p>\n\n<table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:600px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>-d, --discover &lt;absolute path to file&gt;</td>\n\t\t\t<td>Dumps discovery information in XML format to &lt;file&gt;</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-e, --reflash</td>\n\t\t\t<td>Flash even if the device is already up to date</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-f, &nbsp;--force</td>\n\t\t\t<td>Always flash applicable devices (same as -e -g)</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-g, --downgrade</td>\n\t\t\t<td>Flash if the device has a later firmware</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-s, --silent</td>\n\t\t\t<td>Do not display any text and no user interaction required</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;</p>\n\n<p><strong>Remote Online:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li>\n\t<li>Run the launch_sum.bat in the root of the ISO.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v177052/D3000_P07231-006.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE D3600/D3700/D3610/D3710 12Gb SAS Disk Enclosure ROM Flash Component for VMware (ESXi)"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"id":"D3600","target_guid":"","type":"sas"},{"id":"D3700","target_guid":"","type":"sas"},{"id":"D3610","target_guid":"","type":"sas"},{"id":"D3710","target_guid":"","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-17T12:58:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p>\n\n<ul>\n\t<li>\n\t<p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p>\n\t</li>\n\t<li>\n\t<p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p>\n\t</li>\n\t<li>\n\t<p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p>\n\t</li>\n\t<li>\n\t<p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p>\n\t</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v177052/D3000_P07231-006.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"}],"sw_keys":[{"name":"D3710","sw_key_expectedpath":"firmware:sd:disk_enclosure"},{"name":"D3610","sw_key_expectedpath":"firmware:sd:disk_enclosure"},{"name":"D3600","sw_key_expectedpath":"firmware:sd:disk_enclosure"},{"name":"D3700","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB8000GFECR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRPTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3842-3030-304746454352","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB8000GFECR"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB8000GFECR Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPG5</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPG5<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"17251527","datemodified":"2021-08-27T04:46:57","file_list":["/CP048381_BUILD_2.data","/CP048381.vmexe","/CP048381.vmexe64","/CP048381.vmfile","/CP048381_VMw.zip","/CP048381.xml","/payload.json","/CP048381_VMw.zip/index.xml","/CP048381_VMw.zip/vendor-index.xml","/CP048381_VMw.zip/metadata.zip","/CP048381_VMw.zip/vib20/CP048381/HPE_bootbank_CP048381_HPG6.2-7.0.0.15843807.vib","/CP048381_VMw.zip/metadata.zip/vendor-index.xml","/CP048381_VMw.zip/metadata.zip/vmware.xml","/CP048381_VMw.zip/metadata.zip/vibs/CP048381-4290166914378001619.xml","/CP048381_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048381_HPG6.2-7.0.0.15843807.xml"],"md5sum":"aafbffd66d305a264a191a594b5bdc67","name":"CP048381.zip","release":"2021-08-27T04:42:06","revision":"0","sha1sum":"01f630cc05cdb20d605d41c97eeabc3f8186901f","size":"16MB","target_guids":["002340a5-4d00-3842-3030-304746454352"],"type_of_change":"1","version":"HPG6","vib_list":[{"name":"CP048381","version":"HPG6.2-7.0.0.15843807"}]}],"id":{"product":"4e50152f0d024f97a52057a7a5220f5a","version":"0d5a0f4924e34b289904c41a3dc4dc62"},"installation":{"command":"CP040516.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB8000GFECR Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB8000GFECRドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB8000GFECR","target_guid":"002340a5-4d00-3842-3030-304746454352","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T09:02:23","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB8000GFECR","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000GEQNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPFCGB.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304745514e48","Version":"HPGB"},{"DeviceName":"MB6000GEQNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPFCGB.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745514e4b","Version":"HPGB"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB4000GEQNH and MB6000GEQNK"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MB4000GEQNHおよびMB6000GEQNK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB4000GEQNH and MB6000GEQNK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGB<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG7</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.&nbsp; This issue was found during supplier ongoing reliability testing.</p>\n\t</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3706384","datemodified":"2021-07-25T14:38:56","file_list":["cp048593.xml","cpqsetup.exe","HAKPFCGB.REL","payload.json","setup.dll"],"md5sum":"5d47ca1179552f3210d8bb5797bcea9f","name":"cp048593.exe","release":"2021-07-25T14:31:11","revision":"0","sha1sum":"12de3f09d4fe9d59cc7836b97c06873ce66eb526","size":"3MB","target_guids":["002340a5-4d00-3442-3030-304745514e48","002340a5-4d00-3642-3030-304745514e4b"],"type_of_change":"2","version":"HPGB"}],"id":{"product":"8bec8c11bb254125b8c66405c5e73717","version":"13058503c89a47388f6c0217a85d0c9d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB4000GEQNH and MB6000GEQNK Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows(x64) - MB4000GEQNHおよびMB6000GEQNKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB4000GEQNH","target_guid":"002340a5-4d00-3442-3030-304745514e48","type":"sata"},{"id":"MB6000GEQNK","target_guid":"002340a5-4d00-3642-3030-304745514e4b","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T10:26:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was found during supplier ongoing reliability testing.</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was found during supplier ongoing reliability testing.</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000GEQNH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB6000GEQNK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEe0HPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e4c","Version":"HPD4"},{"DeviceName":"EG002400JWJNN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEe0HPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e4e","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: EG001800JWJNL and EG002400JWJNN"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: EG001800JWJNLおよびEG002400JWJNN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG001800JWJNL and EG002400JWJNN Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"4846063","datemodified":"2021-07-26T19:06:35","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD4-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD4-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD4-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD4-2.1/CP049139.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD4-2.1/TA15SEe0HPD4.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD4-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD4-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD4-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD4-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049139.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049139.scexe"],"md5sum":"0d39dc13fe50fbda03323748060e933b","name":"firmware-hdd-852266afdf-HPD4-2.1.x86_64.rpm","release":"2021-07-26T18:54:05","revision":"0","sha1sum":"888acf0dcc62a448c0ce3b5017946d8bba0ffd5a","size":"4MB","target_guids":["452340a5-3047-3130-3830-304a574a4e4c","452340a5-3047-3230-3430-304a574a4e4e"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"5525dd3ac4024adeb1f8ec72b9fd1236","version":"4e33027827de4615ba504887c1b12840"},"installation":{"command":"CP041561.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://www.hp.com/swpublishing/MTX-357c87ee9b054ad7a631d9eaba\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EG001800JWJNL and EG002400JWJNN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - EG001800JWJNLおよびEG002400JWJNNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EG002400JWJNN","target_guid":"452340a5-3047-3230-3430-304a574a4e4e","type":"sas"},{"id":"EG001800JWJNL","target_guid":"452340a5-3047-3130-3830-304a574a4e4c","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T18:49:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware provides a change to the Vendor ID in the VPD page that refers to HP instead of HPE.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001800JWJNL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG002400JWJNN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VS003840KWXFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"85031G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3330-3834-304b57584651","Version":"85031G00"},{"DeviceName":"VS000960KWXFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"85031G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3030-3936-304b5758464e","Version":"85031G00"},{"DeviceName":"VS001920KWXFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"85031G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3130-3932-304b57584650","Version":"85031G00"},{"DeviceName":"VS000480KXALB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"85031G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3030-3438-304b58414c42","Version":"85031G00"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following NVME drive models: VS000480KXALB, VS000960KWXFN, VS001920KWXFP and VS003840KWXFQ"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のNVMEドライブモデルのファームウェアを提供します。VS000480KXALB、VS000960KWXFN、VS001920KWXFP、およびVS003840KWXFQ"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Linux (x64) - VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>85031G00</p>\n\n<p><strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>85030G00</p>\n\n<p><strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>85030G00</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Fixes for various drive reliability enhancements and code fixes accumulated since the last initial release, as well as a change to disable MCTP over PCIe VDM function to satisfy certain HPE platform environments.</li>\n</ul>\n\n<p><strong>Known Issues:</strong></p>\n\n<ul>\n\t<li>Requires iLO5 v2.30 or later, SUM will not detect SSD as applicable for Firmware update for deployment with iLO version older than v2.30</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>提供名：</strong><br />\n      オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - VS000480KXALB、VS003840KWXFQ、VS001920KWXFP、およびVS000960KWXFNドライブ<br />\n <br />\n<strong>リリースバージョンおよび/または日付：<br />\n      </strong>85031G00</p>\n\n<p><strong>最新の推奨またはクリティカルバージョン：<br />\n      </strong> 85030G00</p>\n\n<p><strong>前のファームウェアバージョン：<br />\n      </strong> 85030G00</p>\n\n<p><strong>ファームウェアの関連性:<br />\n      </strong>なし  </p>\n\n<p><strong>改善点/新しい機能：</strong></p>\n\n<p>      なし\n        </p>\n\n<p><strong>修正された問題：</strong></p>\n\n<ul>\n\t<li>前回の初回リリース以降に蓄積されたさまざまなドライブの信頼性の機能強化とコード修正と、特定のHPEプラットフォーム環境を満たすためにMCTP over PCIe VDM機能を無効にする変更の修正です。</li>\n</ul>\n\n<p><strong>既知の問題点:</strong></p>\n\n<ul>\n\t<li>iLO5 v2.30以降が必要です。SUMは、v2.30より前のバージョンのiLOを使用した展開のファームウェアアップデートに適用可能としてSSDを検出しません</li>\n</ul>\n"}],"files":[{"bytes":"7585558","datemodified":"2021-06-07T09:31:11","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85031G00-1.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85031G00-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85031G00-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85031G00-1.1/85031G00_mp.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85031G00-1.1/CP048305.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85031G00-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85031G00-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85031G00-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85031G00-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85031G00-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048305.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048305.scexe"],"md5sum":"75b6549f9d17d488ceb43d5534a060ee","name":"firmware-hdd-805abb7e9c-85031G00-1.1.x86_64.rpm","release":"2021-06-09T00:00:00","revision":"2","sha1sum":"c2b02f30993701dc9825d88112e02c6d71692968","size":"7MB","target_guids":["562340a5-3053-3330-3834-304b57584651","562340a5-3053-3030-3936-304b5758464e","562340a5-3053-3130-3932-304b57584650","562340a5-3053-3030-3438-304b58414c42"],"type_of_change":"1","version":"85031G00"}],"id":{"product":"f4d3c3f0b12d4c1da09c3d11188e06cf","version":"4e19ea8c6a544bb892f0b9d922dfa366"},"installation":{"command":"CP042967.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p><strong>Additional Information:</strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p><strong>追加情報:</strong></p>\n\n<p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/jp/servers/spp_dl\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN  Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - VS000480KXALB、VS003840KWXFQ、VS001920KWXFP、およびVS000960KWXFNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_devices":[{"id":"VS003840KWXFQ","target_guid":"562340a5-3053-3330-3834-304b57584651","type":"nvme"},{"id":"VS001920KWXFP","target_guid":"562340a5-3053-3130-3932-304b57584650","type":"nvme"},{"id":"VS000960KWXFN","target_guid":"562340a5-3053-3030-3936-304b5758464e","type":"nvme"},{"id":"VS000480KXALB","target_guid":"562340a5-3053-3030-3438-304b58414c42","type":"nvme"},{"dev":"2241","subdev":"02F6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1b4b-2241159002f6","type":"pci","ven":"1B4B"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-18T10:21:36","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This is a maintenance release that contains various drive reliability enhancements and code fixes accumulated since the last initial release, as well as a change to disable MCTP over PCIe VDM function to satisfy certain HPE platform environments.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fixes for various drive reliability enhancements and code fixes accumulated since the last initial release, as well as a change to disable MCTP over PCIe VDM function to satisfy certain HPE platform environments.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"VS003840KWXFQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VS000960KWXFN","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VS001920KWXFP","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VS000480KXALB","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWTSV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757545356","Version":"HPG6"},{"DeviceName":"VK000480GWTTA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757545441","Version":"HPG6"},{"DeviceName":"VK000960GWTTB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757545442","Version":"HPG6"},{"DeviceName":"VK001920GWTTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757545443","Version":"HPG6"},{"DeviceName":"VK003840GWTTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304757545444","Version":"HPG6"},{"DeviceName":"MK000480GWTTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757545448","Version":"HPG6"},{"DeviceName":"MK000960GWTTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-30475754544b","Version":"HPG6"},{"DeviceName":"MK001920GWTTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475754544c","Version":"HPG6"},{"DeviceName":"MK003840GWTTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475754544e","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000240GWTSV、VK000480GWTTA、VK000960GWTTB、VK001920GWTTC、VK003840GWTTD、MK000480GWTTH、MK000960GWTTK、MK001920GWTTL および MK003840GWTTN ドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp; &nbsp;&nbsp; None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3168120","datemodified":"2021-07-22T11:21:03","file_list":["4IYRHPG6.bin","cp048241.xml","cpqsetup.exe","payload.json","setup.dll"],"md5sum":"fbe4c69740eed18dbcb04b236fd7c9fe","name":"cp048241.exe","release":"2021-07-22T11:12:05","revision":"0","sha1sum":"216b7aa442c0c29ee37de1029a84ce481196157c","size":"3MB","target_guids":["562340a5-304b-3030-3234-304757545356","562340a5-304b-3030-3438-304757545441","562340a5-304b-3030-3936-304757545442","562340a5-304b-3130-3932-304757545443","562340a5-304b-3330-3834-304757545444","4d2340a5-304b-3030-3438-304757545448","4d2340a5-304b-3030-3936-30475754544b","4d2340a5-304b-3130-3932-30475754544c","4d2340a5-304b-3330-3834-30475754544e"],"type_of_change":"1","version":"HPG6"}],"id":{"product":"4ec88340a2ce4a0da239c4051a775bd6","version":"734280d0d2cb4ad3849832b98ec2aeed"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - VK000240GWTSV、VK000480GWTTA、VK000960GWTTB、VK001920GWTTC、VK003840GWTTD、MK000480GWTTH、MK000960GWTTK、MK001920GWTTLおよびMK003840GWTTNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VK003840GWTTD","target_guid":"562340a5-304b-3330-3834-304757545444","type":"sata"},{"id":"MK003840GWTTN","target_guid":"4d2340a5-304b-3330-3834-30475754544e","type":"sata"},{"id":"VK001920GWTTC","target_guid":"562340a5-304b-3130-3932-304757545443","type":"sata"},{"id":"MK001920GWTTL","target_guid":"4d2340a5-304b-3130-3932-30475754544c","type":"sata"},{"id":"VK000960GWTTB","target_guid":"562340a5-304b-3030-3936-304757545442","type":"sata"},{"id":"MK000960GWTTK","target_guid":"4d2340a5-304b-3030-3936-30475754544b","type":"sata"},{"id":"VK000480GWTTA","target_guid":"562340a5-304b-3030-3438-304757545441","type":"sata"},{"id":"MK000480GWTTH","target_guid":"4d2340a5-304b-3030-3438-304757545448","type":"sata"},{"id":"VK000240GWTSV","target_guid":"562340a5-304b-3030-3234-304757545356","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-01T10:41:30","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK003840GWTTD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWTTB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWTTA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GWTTC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWTSV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWTTH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK001920GWTTL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWTTK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK003840GWTTN","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the drivers for the HPE Blade QLogic NX2 10/20 GbE Multifunction Gigabit Server Adapters for Windows Server 2012 R2, Windows Server 2016 and Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージは、HPE Blade QLogic NX2 10/20 GbEマルチファンクションGigabitサーバーアダプタードライバーfor Windows Server 2012 R2、Windows Server 2016、およびWindows Server 2019が含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This component contains the following drivers:</p>\n\n<ul>\n\t<li>10GbE VBD driver version 7.13.206.0</li>\n\t<li>NDIS 6.0 driver version 7.13.198.0</li>\n\t<li>FCoE offload driver version 7.14.24.0</li>\n\t<li>FCoE crash dump driver version 7.13.7.0</li>\n\t<li>iSCSI offload driver version 7.14.17.0</li>\n\t<li>iSCSI crash dump driver version 7.13.5.0</li>\n</ul>\n"}],"files":[{"bytes":"3369720","datemodified":"2021-08-12T05:46:10","file_list":["bcm10ginstaller.dll","bnxfcdo.sys","bxfcoe.cat","bxfcoe.inf","bxfcoe.sys","bxfcoeco.dll","bxnd.cat","bxnd.inf","bxnd60a.sys","bxois.cat","bxois.inf","bxois.sys","bxoisco.dll","bxois_release.txt","cp047540.xml","cpqsetup.exe","cp_data.xml","evbd.cat","evbd.inf","evbda.sys","install.xml","QLogic_slipstream.zip","qnxcdo.sys"],"md5sum":"c77a9b4ef4ee3b8b6f3dd19a202421d7","name":"cp047540.exe","release":"2021-08-12T05:29:30","revision":"0","sha1sum":"381715feafa558e73ab5789e5e956bd7314179d5","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec9bc6b74c"],"type_of_change":"0","version":"7.13.206.0"}],"id":{"product":"4a7b934c55fe47768eb7c9f45376dbee","version":"3d983fc42f594c43954cbb888d973f87"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Windows Server x64 Editions"},{"lang":"ja","x_late":"HPE Blade QLogic NX2 10/20 GbE マルチファンクションドライバーfor Windows Server x64 Editions"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_devices":[{"dev":"168E","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1933","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c22fa","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1917","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1916","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1933","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1916","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1917","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c22fa","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1933","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c22fa","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1916","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1917","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-03T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now provides non-SRIOV NIC switch and UDP hash support for Windows Server 2016.</p>\n","latest_fixes_x_late":"<p>This product corrects a Windows Stop Error (BSOD) seen when uninstalling the NDIS driver.<br />\nThis product corrects a BSOD with error code 7E seen when a system is heavily loaded with network traffic.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This driver corrects an issue which results in a Windows Stop Error (BSOD) when an invalid vPort ID is used with NIC VMSwitch.<br />\nThe driver addresses an issue where a network is intermittently disconnected when Virtual Machine Queue (VMQ) is enabled.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"evbda.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO001600KWVNB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b57564e42","Version":"HPK3"},{"DeviceName":"MO003200KWVNC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b57564e43","Version":"HPK3"},{"DeviceName":"MO006400KWVND","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b57564e44","Version":"HPK3"},{"DeviceName":"MT001600KWSTB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3130-3630-304b57535442","Version":"HPK3"},{"DeviceName":"MT003200KWSTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3330-3230-304b57535443","Version":"HPK3"},{"DeviceName":"MT006400KWSTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3630-3430-304b57535444","Version":"HPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MO001600KWVNB, MO003200KWVNC, MO006400KWVND, MT001600KWSTB, MT003200KWSTC and MT006400KWSTD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows (x64) -&nbsp; MO001600KWVNB, MO003200KWVNC, MO006400KWVND, MT001600KWSTB, MT003200KWSTC and MT006400KWSTD Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5391112","datemodified":"2021-07-24T10:59:29","file_list":["cp048684.xml","cpqsetup.exe","GP1725b0HPK3.rel","payload.json","setup.dll"],"md5sum":"7f31b60374177819c8d62735dd2d6cad","name":"cp048684.exe","release":"2021-07-24T10:51:08","revision":"0","sha1sum":"05d4a0a099d95fcdcdcd23315990acd456e41926","size":"5MB","target_guids":["4d2340a5-304f-3130-3630-304b57564e42","4d2340a5-304f-3330-3230-304b57564e43","4d2340a5-304f-3630-3430-304b57564e44","4d2340a5-3054-3130-3630-304b57535442","4d2340a5-3054-3330-3230-304b57535443","4d2340a5-3054-3630-3430-304b57535444"],"type_of_change":"1","version":"HPK3"}],"id":{"product":"12eaa829eeb841af89f7ea134993346e","version":"5b9b64b8ad70467f918a59c513a7499d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\<SPP root folder>\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリに配置します。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) - MO001600KWVNB, MO003200KWVNC, MO006400KWVND, MT001600KWSTB, MT003200KWSTC and MT006400KWSTD Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - MO001600KWVNB、MO003200KWVNC、MO006400KWVND、MT001600KWSTB、MT003200KWSTC、およびMT006400KWSTDドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MO006400KWVND","target_guid":"4d2340a5-304f-3630-3430-304b57564e44","type":"nvme"},{"id":"MO003200KWVNC","target_guid":"4d2340a5-304f-3330-3230-304b57564e43","type":"nvme"},{"id":"MO001600KWVNB","target_guid":"4d2340a5-304f-3130-3630-304b57564e42","type":"nvme"},{"id":"MT001600KWSTB","target_guid":"4d2340a5-3054-3130-3630-304b57535442","type":"nvme"},{"id":"MT003200KWSTC","target_guid":"4d2340a5-3054-3330-3230-304b57535443","type":"nvme"},{"id":"MT006400KWSTD","target_guid":"4d2340a5-3054-3630-3430-304b57535444","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-17T09:19:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Fixed SSD weargauge report error issue.</li>\n\t<li>Fixed Assign FWState as TR_DONE_ERR at the correct location.</li>\n\t<li>Prepare proper response data for Get Message Type Supported MCTP Command.</li>\n\t<li>Added code to preserve current feature values cross live firmware update.</li>\n\t<li>Allocate 4 bytes instead of 2 bytes for parameter code.</li>\n\t<li>Changed the value for NLB equal to NSize -1.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MT006400KWSTD","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO001600KWVNB","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT003200KWSTC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO003200KWVNC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO006400KWVND","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT001600KWSTB","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Intel ixgben Adapters running under VMware vSphere 6.5."},{"lang":"ja","x_late":"この製品は、VMware vSphere 6.5上で動作するHPE Intel ixgbenアダプターのためのドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;1.9.4.0.</p>\n"}],"files":[{"bytes":"196912","datemodified":"2021-05-10T08:41:49","file_list":["/cp045249.xml","/VMW-ESX-6.5.0-ixgben-1.9.11.0-offline_bundle-17672460.zip","/VMW-ESX-6.5.0-ixgben-1.9.11.0-offline_bundle-17672460.zip/index.xml","/VMW-ESX-6.5.0-ixgben-1.9.11.0-offline_bundle-17672460.zip/vendor-index.xml","/VMW-ESX-6.5.0-ixgben-1.9.11.0-offline_bundle-17672460.zip/metadata.zip","/VMW-ESX-6.5.0-ixgben-1.9.11.0-offline_bundle-17672460.zip/vib20/ixgben/INT_bootbank_ixgben_1.9.11.0-1OEM.650.0.0.4598673.vib","/VMW-ESX-6.5.0-ixgben-1.9.11.0-offline_bundle-17672460.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.5.0-ixgben-1.9.11.0-offline_bundle-17672460.zip/metadata.zip/vmware.xml","/VMW-ESX-6.5.0-ixgben-1.9.11.0-offline_bundle-17672460.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-ixgben-1.9.11.0.xml","/VMW-ESX-6.5.0-ixgben-1.9.11.0-offline_bundle-17672460.zip/metadata.zip/vibs/ixgben-7460454770853794822.xml"],"md5sum":"ec10c332349291e01f38d76234407753","name":"cp045249.zip","release":"2021-05-10T08:39:05","revision":"0","sha1sum":"ca561e7fae0aa0cdd3c17986b7500a2c31279c1c","size":"192KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4a9c3d5c"],"type_of_change":"0","version":"2021.04.05","vib_list":[{"name":"ixgben","version":"1.9.11.0-1OEM.650.0.0.4598673"}]}],"id":{"product":"a6351a56dbe64b13b1076909ea7de13e","version":"88085ffafc71413a97233993769a7465"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel ixgben Driver for VMware vSphere 6.5"},{"lang":"ja","x_late":"HPE Intel ixgbenドライバーfor VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c192d","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c211a","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d3","type":"pci","ven":"8086"},{"dev":"1515","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c192d","type":"pci","ven":"8086"},{"dev":"1515","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c211a","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue which notification from Link Partner when executed Link Flow Control settings.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product corrects the maximum supported number of virtual functions.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"ixgben:1.9.11.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox adapter cards."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1946374","datemodified":"2021-05-17T21:24:57","file_list":["./etc/depmod.d/zz01-mlnx-ofa_kernel-bnxt_re.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-efa.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-hfi1.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-i40iw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ipoib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_iser.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_isert.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srp.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srpt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_umad.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_uverbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cxgb4.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_en.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_fpga_tools.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx_compat.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxfw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvme-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvmet-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-opa_vnic.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-qedr.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_rxe.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdmavt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rpcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-siw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-svcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-usnic_verbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-vmw_pvrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-xprtrdma.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/compat","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/compat/mlx_compat.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_cm.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_core.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_ucm.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_umad.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/iw_cm.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_cm.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa/efa.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/i40iw","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/siw","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/siw/siw.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx4","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx4/mlx4_core.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx4/mlx4_en.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/fpga","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/fpga/mlx5_fpga_tools.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host/nvme-rdma.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/net","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/kmod-mlnx-ofa_kernel/component.xml"],"md5sum":"c62b87c6695f9b7723d291baf1f7c0ea","name":"kmod-mlnx-ofa_kernel-4.9-OFED.4.9.3.1.6.1.rhel8u3.x86_64.rpm","release":"2021-05-17T20:23:06","revision":"0","sha1sum":"1a83f4b09625ea8708deea27a0f62b069bd77252","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"4.9"},{"bytes":"2390493","datemodified":"2021-05-17T21:27:40","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/connectx.conf","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d/mlx4.driver","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/security/limits.d/30-libvma-limits.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/82-net-setup-link.rules","./etc/udev/rules.d/90-ib.rules","./sbin/connectx_port_config","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/ibdev2netdev","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_get_vfs.pl","./usr/bin/mlnx_perf","./usr/bin/mlnx_qcn","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/lib/.build-id","./usr/lib/.build-id/01","./usr/lib/.build-id/01/064175c274d110c15f4f6b5e590cfee6b01a85","./usr/lib/.build-id/13","./usr/lib/.build-id/13/122d1ec2609f08b1c57d7419f59f57b8e26cea","./usr/lib/.build-id/29","./usr/lib/.build-id/29/2b326ac0e973fe786c84057aa499932fa8c16a","./usr/lib/.build-id/3a","./usr/lib/.build-id/3a/fe98c4913aa912753dc982b9bb28f2c5adc121","./usr/lib/.build-id/53","./usr/lib/.build-id/53/2956993fb5c8e6e2777abd7e4b85d5e072076c","./usr/lib/.build-id/56","./usr/lib/.build-id/56/26172dc235c964ae6d82257606ae589995874a","./usr/lib/.build-id/7e","./usr/lib/.build-id/7e/8a768c6909c157808a16066a36ebe77fcd6152","./usr/lib/.build-id/87","./usr/lib/.build-id/87/6c5cc61a3966b6ecf8e34bf112de971cdcb13b","./usr/lib/.build-id/93","./usr/lib/.build-id/93/24ae9f18f61d9e603db4a5fd05e18fd6108c57","./usr/lib/.build-id/a1","./usr/lib/.build-id/a1/74740894841f8ec8ce24f1d6d7a0b61f0f9b73","./usr/lib/.build-id/aa","./usr/lib/.build-id/aa/a1fe9f39eb0a02da3e43c7b6d16bf3cac24b4d","./usr/lib/.build-id/aa/e0d1d986438005f73de1e569ffd21e1d0f8616","./usr/lib/.build-id/d1","./usr/lib/.build-id/d1/68b254f5e5ddd6193247cbd4fda1502d77b5a6","./usr/lib/.build-id/d3","./usr/lib/.build-id/d3/4b3e584dcf7498507d9d36bbf024df7df6e4cd","./usr/lib/python3.6/site-packages/dcbnetlink.py","./usr/lib/python3.6/site-packages/genetlink.py","./usr/lib/python3.6/site-packages/netlink.py","./usr/lib/python3.6/site-packages/ofed_le_utils-1.0.3-py3.6.egg-info","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/vma.service","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.0","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.0.0","./usr/lib64/libmlx4-rdmav2.so","./usr/lib64/libmlx5-rdmav2.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.0.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.0.0","./usr/lib64/libvma-debug.so","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.0.2","./usr/lib64/mlnx_ofed/valgrind/libibverbs.so.1","./usr/lib64/mlnx_ofed/valgrind/libibverbs.so.1.0.0","./usr/lib64/mlnx_ofed/valgrind/libmlx4-rdmav2.so","./usr/lib64/mlnx_ofed/valgrind/libmlx4.so","./usr/lib64/mlnx_ofed/valgrind/libmlx5-rdmav2.so","./usr/lib64/mlnx_ofed/valgrind/libmlx5.so.1","./usr/lib64/mlnx_ofed/valgrind/libmlx5.so.1.0.0","./usr/lib64/mlnx_ofed/valgrind/librdmacm.so.1","./usr/lib64/mlnx_ofed/valgrind/librdmacm.so.1.0.0","./usr/lib64/mlnx_ofed/valgrind/rsocket/librspreload.so.1","./usr/lib64/mlnx_ofed/valgrind/rsocket/librspreload.so.1.0.0","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vma","./usr/sbin/vmad","./usr/share/doc/ib2ib","./usr/share/doc/ib2ib/README","./usr/share/doc/libibumad","./usr/share/doc/libibumad/AUTHORS","./usr/share/doc/libibumad/COPYING","./usr/share/doc/libibumad/ChangeLog","./usr/share/doc/libibverbs","./usr/share/doc/libibverbs/AUTHORS","./usr/share/doc/libibverbs/COPYING","./usr/share/doc/libibverbs/ChangeLog","./usr/share/doc/libibverbs/README","./usr/share/doc/libmlx4","./usr/share/doc/libmlx4/AUTHORS","./usr/share/doc/libmlx4/COPYING","./usr/share/doc/libmlx4/README","./usr/share/doc/libmlx5","./usr/share/doc/libmlx5/AUTHORS","./usr/share/doc/libmlx5/COPYING","./usr/share/doc/libmlx5/README","./usr/share/doc/librdmacm","./usr/share/doc/librdmacm/AUTHORS","./usr/share/doc/librdmacm/COPYING","./usr/share/doc/librdmacm/README","./usr/share/doc/libvma-9.0.2/README.txt","./usr/share/doc/libvma-9.0.2/VMA_VERSION","./usr/share/doc/libvma-9.0.2/journal.txt","./usr/share/man/man3/umad_addr_dump.3.gz","./usr/share/man/man3/umad_alloc.3.gz","./usr/share/man/man3/umad_attribute_str.3.gz","./usr/share/man/man3/umad_class_str.3.gz","./usr/share/man/man3/umad_close_port.3.gz","./usr/share/man/man3/umad_debug.3.gz","./usr/share/man/man3/umad_done.3.gz","./usr/share/man/man3/umad_dump.3.gz","./usr/share/man/man3/umad_free.3.gz","./usr/share/man/man3/umad_free_ca_namelist.3.gz","./usr/share/man/man3/umad_get_ca.3.gz","./usr/share/man/man3/umad_get_ca_namelist.3.gz","./usr/share/man/man3/umad_get_ca_portguids.3.gz","./usr/share/man/man3/umad_get_cas_names.3.gz","./usr/share/man/man3/umad_get_fd.3.gz","./usr/share/man/man3/umad_get_issm_path.3.gz","./usr/share/man/man3/umad_get_mad.3.gz","./usr/share/man/man3/umad_get_mad_addr.3.gz","./usr/share/man/man3/umad_get_pkey.3.gz","./usr/share/man/man3/umad_get_port.3.gz","./usr/share/man/man3/umad_init.3.gz","./usr/share/man/man3/umad_mad_status_str.3.gz","./usr/share/man/man3/umad_method_str.3.gz","./usr/share/man/man3/umad_open_port.3.gz","./usr/share/man/man3/umad_poll.3.gz","./usr/share/man/man3/umad_recv.3.gz","./usr/share/man/man3/umad_register.3.gz","./usr/share/man/man3/umad_register2.3.gz","./usr/share/man/man3/umad_register_oui.3.gz","./usr/share/man/man3/umad_release_ca.3.gz","./usr/share/man/man3/umad_release_port.3.gz","./usr/share/man/man3/umad_send.3.gz","./usr/share/man/man3/umad_set_addr.3.gz","./usr/share/man/man3/umad_set_addr_net.3.gz","./usr/share/man/man3/umad_set_grh.3.gz","./usr/share/man/man3/umad_set_grh_net.3.gz","./usr/share/man/man3/umad_set_pkey.3.gz","./usr/share/man/man3/umad_size.3.gz","./usr/share/man/man3/umad_status.3.gz","./usr/share/man/man3/umad_unregister.3.gz","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml","./usr/lib/python3.6/site-packages/__pycache__/dcbnetlink.cpython-36.opt-1.pyc","./usr/lib/python3.6/site-packages/__pycache__/dcbnetlink.cpython-36.pyc","./usr/lib/python3.6/site-packages/__pycache__/genetlink.cpython-36.opt-1.pyc","./usr/lib/python3.6/site-packages/__pycache__/genetlink.cpython-36.pyc","./usr/lib/python3.6/site-packages/__pycache__/netlink.cpython-36.opt-1.pyc","./usr/lib/python3.6/site-packages/__pycache__/netlink.cpython-36.pyc"],"md5sum":"e1e333586fa4c111a34deeb9557a6d94","name":"mlnx-ofa_kernel-4.9-OFED.4.9.3.1.6.1.rhel8u3.x86_64.rpm","release":"2021-05-17T20:23:06","revision":"0","sha1sum":"151befa9b9254b40eed83c8575b57e4f571ca80f","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"4.9"}],"id":{"product":"4dc9d9f9fcc644f387920815a2839446","version":"e98d0cc8fe5f4f2a880d8226ac468e94"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)","OSVersion":{"name":"Linux","value":"6.9"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)","OSVersion":{"name":"Linux","value":"6.10"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)","OSVersion":{"name":"Linux","value":"7.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)","OSVersion":{"name":"Linux","value":"7.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-4.9&quot;&nbsp;RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.&nbsp;<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using kernel version 4.18.0-240.el8.x86_64 or any future errata:<br />\n<br />\n<strong># rpm -Uvh&nbsp;kmod-mlnx-ofa_kernel-4.9-OFED.4.9.3.1.6.1.rhel8u2.x86_64.rpm&nbsp;mlnx-ofa_kernel-4.9-OFED.4.9.3.1.6.1.rhel8u2.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for Red Hat Enterprise Linux 8 update 3 (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-17T17:07:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>The following changes and new features are added in version 4.9:</strong></p>\n\n<ul>\n\t<li><strong>For ConnectX-5 Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Option to dump configuration space via the devlink tool in order to improve debug capabilities.</li>\n\t<li>The conventional TX descriptor (WQE or Work Queue Element) describes a single packet for transmission. Added driver support for the HW feature of multi-packet TX WQEs in XDP transmit flows. With this, the HW becomes capable of working with a new and improved WQE layout that describes several packets. In effect, this feature saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>GENEVE encapsulation/decapsulation rules offload.</li>\n\t<li>Driver support for the hardware feature of multi-packet Tx to work with a new and improved WQE layout that describes several packets instead of a single packet for XDP transmission flows. This saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>Updating CT (Connection Tracking) rules using the software steering mechanism.</li>\n\t<li>Updating remote mirroring rules using the software steering mechanism.<br />\n\t&nbsp;</li>\n\t<li><strong>For ConnectX-4&nbsp;Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Exposed rx_prio[p]_discards discard counters per priority that count the number of received packets dropped due to lack of buffers on the physical port.</li>\n\t<li>Reporting TSO and CSUM offload capabilities for MPLS tagged traffic and, allowed the kernel stack to use these offloads.</li>\n\t<li>mlx5e Max Combined Channels Increased the driver&rsquo;s maximal combined channels value from 64 to 128 (however, note that OOB value will not cross 64). 128 is the upper bound. Lower maximal value can be seen on the host, depending on the number of cores and MSIX&#39;s configured by the firmware.</li>\n\t<li>Added the following RoCE accelerator counters:\n\t<ul>\n\t\t<li>roce_adp_retrans - counts the number of adaptive retransmissions for RoCE traffic.</li>\n\t\t<li>roce_adp_retrans_to - counts the number of times RoCE traffic reached timeout due to adaptive retransmission.</li>\n\t\t<li>roce_slow_restart - counts the number of times RoCE slow restart was used.</li>\n\t\t<li>roce_slow_restart_cnps - counts the number of times RoCE slow restart generated CNP packets roce_slow_restart_trans - counts the number of times RoCE slow restart changed state to slow restart.</li>\n\t</ul>\n\t</li>\n\t<li>User to register memory regions with a relaxed ordering access flag through experimental verbs. This can enhance performance, depending on architecture and scenario.<br />\n\t&nbsp;</li>\n\t<li><strong>For&nbsp;All HCA&#39;s</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Output ibdev2netdev tool output was changed such that the bonding device now points at the bond instead of the slave interface.</li>\n\t<li>Monitoring and recovering from errors that occur on the RX queue, such as cookie errors and timeout.</li>\n\t<li>Improved GSO (Generic Segmentation Offload) workload performance by decreasing doorbells usage to the minimum required.</li>\n\t<li>TX CQE (Completion Queue Element) compression. Saves on outgoing PCIe bandwidth by compressing CQEs together. Disabled by default. Configurable via private flags of ethtool.</li>\n\t<li>Firmware Versions Query via Devlink :Added the option to query for running and stored firmware versions using the devlink tool.</li>\n\t<li>Firmware Flash Update via Devlink :Added the option to update the firmware image in the flash using the devlink tool. Usage: devlink dev flash file .mfa2 For further information on how to perform this update, see &quot;Updating Firmware Using ethtool/devlink and .mfa2 File&quot; section in MFT User Manual.</li>\n\t<li>WQE (Work Queue Element) dump, triggered by an error on Rx/Tx reporters. In addition, some dumps (not triggered by an error) can be retrieved by the user via devlink health reporters.</li>\n\t<li>GENEVE tunneled hardware offloads of TSO, CSUM and RSS.</li>\n\t<li>TCP segmentation and checksum offload support for MPLS-tagged traffic.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 4.9:</strong></p>\n\n<ul>\n\t<li>An issue where injecting EEH (Extended Error Handlng) may cause extra Kernel prints, such as: &ldquo;EEH: Might be infinite loop in mlx5_core driver&rdquo; was fixed.</li>\n\t<li>RPM-based OSs with non-default kernels, using repositories after re-creating the installer (using --add-kernel-support) were&nbsp;resulting&nbsp;in improper installation of the drivers.</li>\n\t<li>A typo in perftest package where help messages wrongly displayed the conversion result between Gb/s and MB/s (20^2 instead of 2^20).</li>\n\t<li>When one of the LAG slaves went down, LAG deactivation failed, ultimately causing bandwidth degradation.</li>\n\t<li>The mlx5 driver maintains a subdirectory for every open eth port in /sys/kernel/debug/. For the default network namespace, the sub-directory name is the name of the interface, like &quot;eth8&quot;. The new convention for the network interfaces moved to the non-default network namespaces is the interfaces name followed by &quot;@&quot; and the port&#39;s PCI ID. For example: &quot;eth8@0000:af:00.3&quot;.</li>\n\t<li>&quot;openibd&quot; script load used to fail when esp6_offload module did not load successfully.</li>\n\t<li>Added dependency of package mpi-selectors on perl-Getopt-Long system package. On minimal installs of RPM-based OSs, installing mpi-selectros will also install the required system package perl-Getopt-Long.</li>\n\t<li>During certain rare scenarios, due to Rx page not being replenished, the same page fragment mistakenly became assigned to two different Rx descriptors.</li>\n\t<li>Driver load issue existed with Errata-kernel on SLES15 SP1.</li>\n\t<li>An issue in the Hairpin feature which prevented adding hairpin flows using TC tool was fixed.</li>\n\t<li>WQ (Work Queue)&nbsp;queue flushing was not handled properly in the event of EEH.</li>\n\t<li>A rare kernel crash scenario when exiting an application that uses RMPP mads intensively.</li>\n\t<li>A possible kernel crash scenario when AER/slot reset in done in parallel to user space commands execution.</li>\n\t<li>Added missing ECN (Explicit Congestion Notification) configuration under sysfs for PFs in SwitchDev mode.</li>\n\t<li>When firmware response time to commands became very long, some commands failed upon timeout. The driver may have then triggered a timeout completion on the wrong entry, leading to a NULL pointer call trace.</li>\n\t<li>Added driver support for kernels with the old XDP_REDIRECT infrastructure that uses the following NetDev operations: .ndo_xdp_flush and .ndo_xdp_xmit.</li>\n\t<li>Usage of --excludedocs Open MPI RPM option resulted in the removal of non-documentation related files.</li>\n\t<li>Disabled automated loading of some modules through udev triggers to preserve the startup process of previous MLNX_OFED versions.</li>\n\t<li>Reference count (refcount) for RDMA connection ID (cm_id) was not incremented in rdma_resolve_addr() function, resulting in a cm_id use-after-free access. A fix was applied to increment the cm_id refcount</li>\n\t<li>A race condition which caused kernel panic when moving two ports to SwitchDev mode at the same time.</li>\n\t<li>Allowed accessing sysfs hardware counters in SwitchDev mode</li>\n\t<li>Function smp_processor_id() is called in the RX page recycle flow to determine the core to run on. This is intended to run in NAPI context. However, due to a bug in backporting, the RX page recycle was mistakenly called also in the RQ close flow when not needed.</li>\n\t<li>Port link state was automatically changed (without admin state involvement) to &quot;UP&quot; after reboot.</li>\n\t<li>ConnectX-3 adapter cards froze when running over SLES 11 OS.</li>\n\t<li>RDMA CM (Remote Direct Memory Access Communation Manager) connection failed when port space was small.</li>\n\t<li>Traffic mirroring with OVS (Open VSwitch)offload and non-offload over VxLAN interface is now supported. Note: For kernel 4.9, make sure to use a dedicated OVS version.</li>\n\t<li>When working with VF LAG while the bond device is in active-active mode, running fwreset would result in unequal traffic on both PFs, and PFs would not reach line rate.</li>\n\t<li>When bond was created over VF (Virtuaal Function)&nbsp;netdevices in SwitchDev mode, the VF netdevice would be treated as representor netdevice. This caused the mlx5_core driver to crash in case it received netdevice events related to bond device.</li>\n\t<li>An issue where following a bad affinity occurrence in VF LAG mode, traffic was sent after the port went up/down in the switch.</li>\n\t<li>Added support for VLAN (Virtual Local Area Network)&nbsp;header rewrite on CentOS 7.2 OS.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"kmod-mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800026","languages":[{"lang":"tw","x_late":"軟體 - 管理"},{"lang":"en","x_late":"Software - Management"},{"lang":"ko","x_late":"소프트웨어 - 관리"},{"lang":"ja","x_late":"ソフトウェア - マネジメント"},{"lang":"cn","x_late":"软件 - 管理"}]}],"description":[{"lang":"en","x_late":"The Smart Storage Administrator CLI is a commandline-based disk configuration program for Smart Array Controllers and SmartRAID Controllers."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"7603541","datemodified":"2021-08-26T17:54:05","file_list":["/cp047066.xml","/ssacli-component_5.20.8.0-7.0.0_18528106.zip","/ssacli-component_5.20.8.0-7.0.0_18528106.zip/index.xml","/ssacli-component_5.20.8.0-7.0.0_18528106.zip/vendor-index.xml","/ssacli-component_5.20.8.0-7.0.0_18528106.zip/metadata.zip","/ssacli-component_5.20.8.0-7.0.0_18528106.zip/vib20/ssacli/MIS_bootbank_ssacli_5.20.8.0-7.0.0.15525992.oem.vib","/ssacli-component_5.20.8.0-7.0.0_18528106.zip/metadata.zip/vendor-index.xml","/ssacli-component_5.20.8.0-7.0.0_18528106.zip/metadata.zip/vmware.xml","/ssacli-component_5.20.8.0-7.0.0_18528106.zip/metadata.zip/vibs/ssacli--3425288372001886076.xml","/ssacli-component_5.20.8.0-7.0.0_18528106.zip/metadata.zip/bulletins/ssacli-component_5.20.8.0-7.0.0.xml"],"md5sum":"ac43bf260f73fdf452a7c49c293c8e5a","name":"cp047066.zip","release":"2021-08-26T17:50:53","revision":"0","sha1sum":"17ae359019c538ed48f27b51175e5257cd20bad7","size":"7MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb7badd80","20a6e8e4-bf33-4c71-a6bf-d9ecff0816bd"],"type_of_change":"1","version":"2021.09.01","vib_list":[{"name":"ssacli","version":"5.20.8.0-7.0.0.15525992.oem"}]}],"id":{"product":"701e4c02b7354b79b14e21a9c2a46dd5","version":"3efac324f4a44f2c8321f3c1b9d7adf4"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To&nbsp;install this bundle using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the component zip file to extract the driver offline bundle.</li>\n\t<li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li>\n</ol>\n\n<p>Refer to VMware documentation for information on the esxcli commands</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Smart Storage Administrator (SSA) CLI Smart Component for ESXi 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"7100"},"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-09T08:28:49","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL215n Gen10 Plus"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"","value":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U14","value":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE ProLiant XL770f Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U27","value":"HPE ProLiant XL2x260w Gen9 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U51","value":"HPE ProLiant XL920g Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"","value":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"key":"U38","value":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U38","value":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"}],"sw_keys":[{"name":"ssacli-component:5.20.8.0-7.0.0","sw_key_expectedpath":"software.component:vmware:zip"},{"name":"ssacli:5.20.8.0-7.0.0.15525992.oem","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000JVYYV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMPN6SD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a56595956","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB6000JVYYV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB6000JVYYV&nbsp;Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3695480","datemodified":"2021-07-25T15:55:15","file_list":["cp048615.xml","cpqsetup.exe","payload.json","setup.dll","SMPN6SD2.rel"],"md5sum":"c98e22e7da7f3691c5b06a2d287e67f9","name":"cp048615.exe","release":"2021-07-25T15:47:05","revision":"0","sha1sum":"45468c22ab9c738f7f6f23a7d5a9d060997ab9a3","size":"3MB","target_guids":["002340a5-4d00-3642-3030-304a56595956"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"eec8feb6cff84dc79bfbc2fc3ee22488","version":"4f6df427c5a84b978ab58bab012ca65e"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB6000JVYYV Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB6000JVYYVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB6000JVYYV","target_guid":"002340a5-4d00-3642-3030-304a56595956","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T12:07:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000JVYYV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000800JXBEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a58424556","Version":"HPD1"},{"DeviceName":"MO001600JXBFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a58424650","Version":"HPD1"},{"DeviceName":"MO003200JXBFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a58424651","Version":"HPD1"},{"DeviceName":"MO006400JXBFR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a58424652","Version":"HPD1"},{"DeviceName":"MO000960JXBFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3936-304a58424641","Version":"HPD1"},{"DeviceName":"MO001920JXBFT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a58424654","Version":"HPD1"},{"DeviceName":"MO003840JXBFU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3834-304a58424655","Version":"HPD1"},{"DeviceName":"MO007680JXBGA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3730-3638-304a58424741","Version":"HPD1"},{"DeviceName":"MO015360JXBFV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3531-3336-304a58424656","Version":"HPD1"},{"DeviceName":"EO000400JXBEU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304a58424555","Version":"HPD1"},{"DeviceName":"EO000800JXBFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304a5842464c","Version":"HPD1"},{"DeviceName":"EO001600JXBFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-304a5842464e","Version":"HPD1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MO000800JXBEV、MO001600JXBFP、MO003200JXBFQ、MO006400JXBFR、MO000960JXBFA、MO001920JXBFT、MO003840JXBFU、MO007680JXBGA、MO015360JXBFV、EO000400JXBEU、EO000800JXBFL およびEO001600JXBFN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp; </strong>None</p>\n"}],"files":[{"bytes":"17013326","datemodified":"2021-08-30T04:50:23","file_list":["/CP049157_BUILD_2.data","/CP049157.vmexe","/CP049157.vmexe64","/CP049157.vmfile","/CP049157_VMw.zip","/CP049157.xml","/payload.json","/CP049157_VMw.zip/index.xml","/CP049157_VMw.zip/vendor-index.xml","/CP049157_VMw.zip/metadata.zip","/CP049157_VMw.zip/vib20/CP049157/HPE_bootbank_CP049157_HPD1.2-7.0.0.15843807.vib","/CP049157_VMw.zip/metadata.zip/vendor-index.xml","/CP049157_VMw.zip/metadata.zip/vmware.xml","/CP049157_VMw.zip/metadata.zip/vibs/CP049157-1279167040823740025.xml","/CP049157_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049157_HPD1.2-7.0.0.15843807.xml"],"md5sum":"3ee77f733c998441e1b8df8e32b308d6","name":"CP049157.zip","release":"2021-08-30T04:45:25","revision":"0","sha1sum":"f1c8ed1fe019951c35c4b6d32cb79cbb18d0bdf3","size":"16MB","target_guids":["4d2340a5-304f-3030-3830-304a58424556","4d2340a5-304f-3130-3630-304a58424650","4d2340a5-304f-3330-3230-304a58424651","4d2340a5-304f-3630-3430-304a58424652","4d2340a5-304f-3030-3936-304a58424641","4d2340a5-304f-3130-3932-304a58424654","4d2340a5-304f-3330-3834-304a58424655","4d2340a5-304f-3730-3638-304a58424741","4d2340a5-304f-3531-3336-304a58424656","452340a5-304f-3030-3430-304a58424555","452340a5-304f-3030-3830-304a5842464c","452340a5-304f-3130-3630-304a5842464e"],"type_of_change":"1","version":"HPD1","vib_list":[{"name":"CP049157","version":"HPD1.2-7.0.0.15843807"}]}],"id":{"product":"d0558c4ca40d4c1889688fd366d72022","version":"32205c4f8a6248bab0ef42be03d928cc"},"installation":{"command":"CP040573.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MO000800JXBEV、MO001600JXBFP、MO003200JXBFQ、MO006400JXBFR、MO000960JXBFA、MO001920JXBFT、MO003840JXBFU、MO007680JXBGA、MO015360JXBFV、EO000400JXBEU、EO000800JXBFLおよびEO001600JXBFNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MO000800JXBEV","target_guid":"4d2340a5-304f-3030-3830-304a58424556","type":"sas"},{"id":"MO001600JXBFP","target_guid":"4d2340a5-304f-3130-3630-304a58424650","type":"sas"},{"id":"MO003200JXBFQ","target_guid":"4d2340a5-304f-3330-3230-304a58424651","type":"sas"},{"id":"MO006400JXBFR","target_guid":"4d2340a5-304f-3630-3430-304a58424652","type":"sas"},{"id":"MO000960JXBFA","target_guid":"4d2340a5-304f-3030-3936-304a58424641","type":"sas"},{"id":"MO001920JXBFT","target_guid":"4d2340a5-304f-3130-3932-304a58424654","type":"sas"},{"id":"MO003840JXBFU","target_guid":"4d2340a5-304f-3330-3834-304a58424655","type":"sas"},{"id":"MO007680JXBGA","target_guid":"4d2340a5-304f-3730-3638-304a58424741","type":"sas"},{"id":"MO015360JXBFV","target_guid":"4d2340a5-304f-3531-3336-304a58424656","type":"sas"},{"id":"EO000400JXBEU","target_guid":"452340a5-304f-3030-3430-304a58424555","type":"sas"},{"id":"EO000800JXBFL","target_guid":"452340a5-304f-3030-3830-304a5842464c","type":"sas"},{"id":"EO001600JXBFN","target_guid":"452340a5-304f-3130-3630-304a5842464e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-27T15:22:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;. Support for second source PMIC from IDT.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MO001920JXBFT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000400JXBEU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800JXBEV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003840JXBFU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200JXBFQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO015360JXBFV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO001600JXBFN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600JXBFP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000960JXBFA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO007680JXBGA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000800JXBFL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO006400JXBFR","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO007680JWCNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633HD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304a57434e4b","Version":"HPD8"},{"DeviceName":"VO015300JWCNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633HD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3330-304a57434e4c","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO007680JWCNK and VO015300JWCNL"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO007680JWCNKおよびVO015300JWCNL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - VO007680JWCNK and VO015300JWCNL&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3402912","datemodified":"2021-07-25T19:29:26","file_list":["cp048644.xml","cpqsetup.exe","G1633HD8.rel","payload.json","setup.dll"],"md5sum":"ea5745f24d9b8fdb900c76f7d2e5dbbb","name":"cp048644.exe","release":"2021-07-25T19:22:04","revision":"0","sha1sum":"b5648fd5aa42852937ce537190db4fcab045b292","size":"3MB","target_guids":["562340a5-304f-3730-3638-304a57434e4b","562340a5-304f-3531-3330-304a57434e4c"],"type_of_change":"2","version":"HPD8"}],"id":{"product":"2ce3ac2092b94fa1b8631b7964992fb7","version":"7cebe83290db4e648c7da439fe9de698"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VO007680JWCNK and VO015300JWCNL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - VO007680JWCNKおよびVO015300JWCNLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VO015300JWCNL","target_guid":"562340a5-304f-3531-3330-304a57434e4c","type":"sas"},{"id":"VO007680JWCNK","target_guid":"562340a5-304f-3730-3638-304a57434e4b","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T17:52:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO007680JWCNK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO015300JWCNL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GEQUT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHc8HaoeFGB.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745515554","Version":"HPGB"},{"DeviceName":"MB8000GEQUU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHc8HaoeFGB.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3842-3030-304745515555","Version":"HPGB"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB6000GEQUT and MB8000GEQUU"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB6000GEQUT and MB8000GEQUU Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGB<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGA<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPGA</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.&nbsp; This issue was only found during supplier ongoing reliability testing.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3685240","datemodified":"2021-07-25T15:23:22","file_list":["cp048611.xml","cpqsetup.exe","HAHc8HaoeFGB.REL","payload.json","setup.dll"],"md5sum":"1f879e62379cb58367c51df84a217480","name":"cp048611.exe","release":"2021-07-25T15:16:05","revision":"0","sha1sum":"f5fefe5a8203b8b0797975c9ac6d1112f22ae8ed","size":"3MB","target_guids":["002340a5-4d00-3642-3030-304745515554","002340a5-4d00-3842-3030-304745515555"],"type_of_change":"2","version":"HPGB"}],"id":{"product":"5eebb17653054977b3ae3cbb9a44ff98","version":"e37d79d849da44039c3fcf2da5954a5d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB6000GEQUT and MB8000GEQUU Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows(x64) - MB6000GEQUTおよびMB8000GEQUUドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB6000GEQUT","target_guid":"002340a5-4d00-3642-3030-304745515554","type":"sata"},{"id":"MB8000GEQUU","target_guid":"002340a5-4d00-3842-3030-304745515555","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T11:25:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was only found during supplier ongoing reliability testing.</li>\n\t<li>Online firmware update fails when drives are connected behind AHCI controller.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was only found during supplier ongoing reliability testing.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB8000GEQUU","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB6000GEQUT","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager（SUM）と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5913352","datemodified":"2021-05-18T04:43:30","file_list":["SignedImageInstaller64.dll","U21_2.90_04_29_2021.signed.flash","cp047839.xml","cpqsetup.exe","cpqsysio64.sys"],"md5sum":"4a5dfec3505e1450f023ffe58583ff08","name":"cp047839.exe","release":"2021-05-18T04:27:09","revision":"0","sha1sum":"7a5f68f4b7139a4cd213f99aecca824f14658236","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021"}],"id":{"product":"f9c6be089c7b4d0089fc2a6d2c32cc55","version":"ea834e3c8c1f4992a14b1d3b58f52222"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant XL450 Gen9 (U21) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant XL450 Gen9 (U21)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-05T03:30:49","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"}],"sw_keys":[{"name":"U21","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the HPE Apollo 2000 - SAS Expander"},{"lang":"ja","x_late":"このSmartコンポーネントは、HPE Apollo 2000 - SASエキスパンダーのファームウェアを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for Windows &ndash; HPE Apollo 2000 System -&nbsp;SAS Expander</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.52<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;1.00 (E)<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;NA<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Fixed an issue in the HPE Apollo 2000 System SAS Expander FW where the HDD Zoning Table would be set to default after upgrading to 1.51</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"},{"lang":"ja","x_late":"<p><strong>提供名：</strong><br />\n     オンラインROMフラッシュコンポーネントfor Windows - HPE Apollo 2000 System - SASエキスパンダー</p>\n\n<p><strong>リリースバージョンおよび/または日付:</strong><br />\n     1.52<br />\n<br />\n<strong>最新の推奨またはクリティカルバージョン:</strong><br />\n     1.00 (E)<br />\n<br />\n<strong>前のファームウェアバージョン:</strong><br />\n     NA<br />\n<br />\n<strong>ファームウェアの関連性：</strong><br />\n     なし\n        <br />\n<br />\n<strong>改善点/新しい機能：</strong></p>\n\n<p>     なし\n        </p>\n\n<p><strong>修正された問題点：</strong></p>\n\n<ul>\n\t<li>HPE Apollo 2000 System SAS Expander FWで、1.51にアップグレードするとHDDのゾーニングテーブルがデフォルトに設定される問題を修正しました。</li>\n</ul>\n\n<p><strong>既知の問題点:</strong><br />\n     なし\n        </p>\n"}],"files":[{"bytes":"3580296","datemodified":"2019-12-04T10:20:34","file_list":["cp041644.xml","cpqsetup.exe","firmware-Release-1.52-build-000.bin.fw","setup.dll"],"md5sum":"e73bc7bdf4efa1f644871d88392987e6","name":"cp041644.exe","release":"2020-01-27T00:00:00","revision":"1","sha1sum":"aa44a5d61123b58383061d6344a0344bbe1930a7","size":"3MB","target_guids":[],"type_of_change":"1","version":"1.52"}],"id":{"product":"6f346518c20d40dba8036f1e105d5ddf","version":"249acd0d925a4f68a81150cb09c59cb1"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a><strong>:</strong></strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li>\n\t<li>Run launch_sum.bat script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p><strong>Additional Information:</strong></p>\n\n<ul>\n\t<li>System AC/DC power cycle is required after a firmware update in order for the update to take effect and for hardware stability to be maintained.</li>\n\t<li>To perform a system AC/DC power cycle: &nbsp;Disconnect the power cords from the server, wait 5 seconds and then reinsert the power cords.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a><strong></strong></strong>から以下の手順に従ってください：</p>\n\n<ul>\n\t<li>ディレクトリ\\SPP20xxxxx\\hp\\swpackagesにアップデートに必要なファームウェアをコピーします。</li>\n\t<li>ISOのルートにあるlaunch_sum.batスクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n\n<p><strong>追加情報：</strong></p>\n\n<ul>\n\t<li>アップデートを有効にして、ハードウェアの安定性を維持するには、ファームウェアのアップデート後にシステムのAC/DC電源を再投入する必要があります。</li>\n\t<li>システムのAC/DC電源の再投入を実行するには、以下の手順に従ってください。 サーバーから電源コードを取り外し、5秒待ってから電源コードを再度取り付けます。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows (x64) - HPE Apollo 2000 System - SAS Expander"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Windows (x64) - HPE Apollo 2000 System - SASエキスパンダー"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_devices":[{"dev":"3239","subdev":"21c2","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c7","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cb","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-03-27T14:28:19","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Fixed an issue in the HPE Apollo 2000 System SAS Expander FW where the HDD Zoning Table would be set to default after upgrading to 1.51</p>\n\n<p>Please reference Customer Advisory SIK5264.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fixed an issue in the HPE Apollo 2000 System SAS Expander FW where the HDD Zoning Table would be set to default after upgrading to 1.51</p>\n\n<p>Please reference Customer Advisory <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00095304en_us\" style=\"color:#0563c1; text-decoration:underline\">a00095304en_us</a>.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"}],"sw_keys":[{"name":"HP Apollo r2800","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO0400KEFHN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3430-304b4546484e","Version":"HPK4"},{"DeviceName":"MO0800KEFHP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3830-304b45464850","Version":"HPK4"},{"DeviceName":"MO1600KEFHQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304b45464851","Version":"HPK4"},{"DeviceName":"MO2000KEFHR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-324f-3030-304b45464852","Version":"HPK4"},{"DeviceName":"MT0800KEXUU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3054-3830-304b45585555","Version":"HPK4"},{"DeviceName":"MT1600KEXUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3154-3630-304b45585556","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MO0400KEFHN, MO0800KEFHP, MO1600KEFHQ, MO2000KEFHR, MT0800KEXUU, and MT1600KEXUV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Windows&nbsp;(x64) - MO0400KEFHN, MO0800KEFHP, MO1600KEFHQ, MO2000KEFHR, MT0800KEXUU and MT1600KEXUV Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"2877000","datemodified":"2021-07-25T12:16:47","file_list":["4IFDHPK4.rel","cp048475.xml","cpqsetup.exe","payload.json","setup.dll"],"md5sum":"2f46972b81c112709218f2d4a6056450","name":"cp048475.exe","release":"2021-07-25T12:08:05","revision":"0","sha1sum":"3372a7e6a47b04b007dda59e2868bbc775328125","size":"2MB","target_guids":["002340a5-4d00-304f-3430-304b4546484e","002340a5-4d00-304f-3830-304b45464850","002340a5-4d00-314f-3630-304b45464851","002340a5-4d00-324f-3030-304b45464852","002340a5-4d00-3054-3830-304b45585555","002340a5-4d00-3154-3630-304b45585556"],"type_of_change":"1","version":"HPK4"}],"id":{"product":"d005de5acf9c47539dbd7a9056630a05","version":"80087d8d475f462e8a9cee1c6620a50d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\<SPP root folder>\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"http://www.hpe.com/jp/servers/spp_dl\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリに配置します。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) -  MO0400KEFHN, MO0800KEFHP, MO1600KEFHQ, MO2000KEFHR, MT0800KEXUU and MT1600KEXUV Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Windows(x64)- MO0400KEFHN、MO0800KEFHP、MO1600KEFHQ、MO2000KEFHR、MT0800KEXUU、およびMT1600KEXUVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MT0800KEXUU","target_guid":"002340a5-4d00-3054-3830-304b45585555","type":"nvme"},{"id":"MT1600KEXUV","target_guid":"002340a5-4d00-3154-3630-304b45585556","type":"nvme"},{"id":"MO0400KEFHN","target_guid":"002340a5-4d00-304f-3430-304b4546484e","type":"nvme"},{"id":"MO0800KEFHP","target_guid":"002340a5-4d00-304f-3830-304b45464850","type":"nvme"},{"id":"MO1600KEFHQ","target_guid":"002340a5-4d00-314f-3630-304b45464851","type":"nvme"},{"id":"MO2000KEFHR","target_guid":"002340a5-4d00-324f-3030-304b45464852","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T17:18:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for&nbsp;Microsoft Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MT0800KEXUU","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT1600KEXUV","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO0400KEFHN","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO2000KEFHR","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO1600KEFHQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO0800KEFHP","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Blade Intel ixgbe Ethernet NICs running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 8で動作するHPE Blade Intel ixgbe Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"185259","datemodified":"2021-07-21T17:26:42","file_list":["./etc/depmod.d/hp-ixgbe.conf","./lib/modules/4.18.0-193.el8.x86_64","./lib/modules/4.18.0-193.el8.x86_64/extra","./lib/modules/4.18.0-193.el8.x86_64/extra/hp-ixgbe","./lib/modules/4.18.0-193.el8.x86_64/extra/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/kmod-hp-ixgbe_bl/component.xml"],"md5sum":"710c819bbf4523385a134b42c898f900","name":"kmod-hp-ixgbe_bl-5.9.4-1.rhel8u2.x86_64.rpm","release":"2021-07-21T17:19:04","revision":"0","sha1sum":"37ab0a41078ab565404edf7adcc819f43b4b3c84","size":"180KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec05844b56"],"type_of_change":"0","version":"5.9.4-1"},{"bytes":"185419","datemodified":"2021-07-21T17:29:20","file_list":["./etc/depmod.d/hp-ixgbe.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/hp-ixgbe","./lib/modules/4.18.0-240.el8.x86_64/extra/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/kmod-hp-ixgbe_bl/component.xml"],"md5sum":"753e60b12794d92d9b7fda725e0cc185","name":"kmod-hp-ixgbe_bl-5.9.4-2.rhel8u3.x86_64.rpm","release":"2021-07-21T17:19:04","revision":"0","sha1sum":"b35d40d8267c3fd8c64fd7abcfc1e47cb6cec747","size":"181KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec05844b56"],"type_of_change":"0","version":"5.9.4-1"}],"id":{"product":"6a2763c5a8ec446e809e71991d4253f9","version":"a4f2c3819b114b27943e712cdd50e15c"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>\n\n<p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>\n\n<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>\n\n<p> </p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Intel ixgbe Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE Blade Intel ixgbeドライバー for Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c18d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-09-03T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 8, Updates 2&nbsp;and 3.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports the&nbsp;HPE ProLiant BL660c Gen9 Server.&nbsp;</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"kmod-hp-ixgbe_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbe_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbe_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbe_bl","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This component package contains the HPE iavf driver for Intel i40ea and Intel i40eb Ethernet NICs running under Microsoft Windows Server 2016."},{"lang":"ja","x_late":"このコンポーネントパッケージには、Microsoft Windows Server 2016で動作しているIntel i40eaおよびIntel i40eb Ethernet NIC用のHPE iavfドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1442248","datemodified":"2021-01-09T07:55:37","file_list":["cp045011.xml","cpqsetup.exe","cp_data.xml","iavf65.cat","iavf65.din","iavf65.inf","iavf65.sys","iavfmsg.dll","install.xml","nicco5.dll","nicdrvr.dll","NicInAVF.dll"],"md5sum":"cea7da9999e8eb9b24eea21fc4ed6428","name":"cp045011.exe","release":"2021-01-09T07:37:04","revision":"0","sha1sum":"96e18c5bee40225ff648f733e4148921304a6aaf","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecc729bb39"],"type_of_change":"0","version":"1.12.9.0"}],"id":{"product":"d480f616863140bd906bb9e3934e35ae","version":"51c863ae26a042a3bf499fe0420670f2"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel iavf Driver for Windows Server 2016"},{"lang":"ja","x_late":"HPE Intel iavfドライバー for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"37CD","subdev":"0000","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"37CD","subdev":"0001","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-37cd80860001","type":"pci","ven":"8086"},{"dev":"1571","subdev":"0001","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-157180860001","type":"pci","ven":"8086"},{"dev":"1571","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"154c","subdev":"0000","subven":"103c","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product is updated to maintain compatibility with updated Windows installation library iavfmsg.dll.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"iavf65.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"HPE QLogic Mezzanine Fibre Channel driver for VMware vSphere 6.7"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"812623","datemodified":"2021-08-27T04:27:52","file_list":["/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip","/cp048709.xml","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/doc/README.txt","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/doc/release_note_qlnativefc_3.1.46.0-1OEM.670.0.0.8169922.qlnativefc","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/index.xml","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/vendor-index.xml","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/metadata.zip","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/vib20/qlnativefc/Marvell_bootbank_qlnativefc_3.1.46.0-1OEM.670.0.0.8169922.vib","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/metadata.zip/vendor-index.xml","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/metadata.zip/vmware.xml","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/metadata.zip/vibs/qlnativefc-3264416984770026613.xml","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/metadata.zip/bulletins/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922.xml"],"md5sum":"25d7ae45d997ce3bf33e66b4fc6dc9e9","name":"cp048709.zip","release":"2021-08-27T04:27:07","revision":"0","sha1sum":"316d6cf0918114c3bf08becb88f156cc301ee261","size":"793KB","target_guids":[],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"qlnativefc","version":"3.1.46.0-1OEM.670.0.0.8169922"}]}],"id":{"product":"4a5ace533ab74dccb3efd98a7f0526db","version":"dda056f4bba84be0b0bfa03d5f0e0eba"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware&nbsp;vSphere Update Manager&nbsp;or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VMware&nbsp;vSphere Update Manager and the esxcli commands</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic Mezzanine Fibre Channel driver component for VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-18T06:27:09","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Made improvements to the Fabric Port Identification Number (FPIN) and Universal Storage Area Network (SAN) Congestion Mitigation(USCM) Congestion Management algorithm</li>\n\t<li>\n\t<p>Implemented the vmkmgmt Application programming Interface (API) to report Non-Volatile Memory Express (NVMe) target info and send Non-Volatile Memory Express (NVMe) pass through commands</p>\n\t</li>\n</ul>\n\n<p>Driver version 3.1.46.0</p>\n","curr_fixes_x_late":"<ul>\n\t<li>Fixed an unwanted behavior where Get Port Speed Capabilities (GPSC) failures were leading to intelligent interleaved direct memory access (IIDMA) for target being set to 1GB/s. This is described in <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00115969en_us\">Advisory: HPE Host Bus Adapters - HPE Platforms Running VMware ESXi 6.5 / 6/7 / 7.0 and Configured With Certain HPE Host Bus Adapters May Experience Severe Performance Degradation When Connected to Brocade FOS v8.0.1 (or Prior)</a></li>\n\t<li>Addressed unwanted behavior with Fabric Port Identification Number (FPIN) based congestion throttling leading to poor performance.</li>\n\t<li>Fixed an unwanted behavior where stale connection IDs could be used with Fibre Channel- Non Volatile Memory Express (FC-NVMe) traffic.</li>\n\t<li>\n\t<p>Fixed an unwanted behavior with response queue handling to avoid the problem referenced by <a href=\"https://kb.vmware.com/s/article/81721\">https://kb.vmware.com/s/article/81721</a></p>\n\t</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"qlnativefc:3.1.46.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Intel igbn Adapters running under VMware vSphere 6.7."},{"lang":"ja","x_late":"この製品は、VMware vSphere 6.7.上で動作するHPE Intel igbnアダプターのためのドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;1.5.2.0.</p>\n"}],"files":[{"bytes":"125136","datemodified":"2021-08-11T09:30:30","file_list":["/cp047110.xml","/Intel-igbn_1.5.2.0-1OEM.670.0.0.8169922-offline_bundle-17205327.zip","/Intel-igbn_1.5.2.0-1OEM.670.0.0.8169922-offline_bundle-17205327.zip/index.xml","/Intel-igbn_1.5.2.0-1OEM.670.0.0.8169922-offline_bundle-17205327.zip/vendor-index.xml","/Intel-igbn_1.5.2.0-1OEM.670.0.0.8169922-offline_bundle-17205327.zip/metadata.zip","/Intel-igbn_1.5.2.0-1OEM.670.0.0.8169922-offline_bundle-17205327.zip/vib20/igbn/INT_bootbank_igbn_1.5.2.0-1OEM.670.0.0.8169922.vib","/Intel-igbn_1.5.2.0-1OEM.670.0.0.8169922-offline_bundle-17205327.zip/metadata.zip/vendor-index.xml","/Intel-igbn_1.5.2.0-1OEM.670.0.0.8169922-offline_bundle-17205327.zip/metadata.zip/vmware.xml","/Intel-igbn_1.5.2.0-1OEM.670.0.0.8169922-offline_bundle-17205327.zip/metadata.zip/vibs/igbn-4393841119758955275.xml","/Intel-igbn_1.5.2.0-1OEM.670.0.0.8169922-offline_bundle-17205327.zip/metadata.zip/bulletins/Intel-igbn_1.5.2.0-1OEM.670.0.0.8169922.xml"],"md5sum":"c43217d44cb09b9a70102b4aedc3d9b1","name":"cp047110.zip","release":"2021-08-11T09:27:09","revision":"0","sha1sum":"5f2b8d39d3bae779bf44d52eb8f0efb2729812c7","size":"122KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55"],"type_of_change":"0","version":"2021.09.04","vib_list":[{"name":"igbn","version":"1.5.2.0-1OEM.670.0.0.8169922"}]}],"id":{"product":"91032ccb9de142bdafa34467279d1727","version":"ab67323e385142baa64455d69bccf0bc"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel igbn Driver for VMware vSphere 6.7"},{"lang":"ja","x_late":"HPE Intel igbnドライバーfor VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"1523","subdev":"1989","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1523103c1989","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00FF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1521159000ff","type":"pci","ven":"8086"},{"dev":"1521","subdev":"337F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c337f","type":"pci","ven":"8086"},{"dev":"1521","subdev":"339E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c339e","type":"pci","ven":"8086"},{"dev":"1521","subdev":"17D1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c17d1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"3380","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-1521103c3380","type":"pci","ven":"8086"},{"dev":"1521","subdev":"8157","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c8157","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00A3","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a3","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue which handling duplex value passed of ESXi command.</p>\n"},{"curr_enhancements_x_late":"<p>This product enhances the reliability of TX/RX ring hang detection and recovery procedures.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"igbn:1.5.2.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000240GWKVK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3234-3047574b564b","Version":"HPG5"},{"DeviceName":"MK000480GWJPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-3047574a504e","Version":"HPG5"},{"DeviceName":"MK000960GWJPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-3047574a5050","Version":"HPG5"},{"DeviceName":"MK001920GWJPQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-3047574a5051","Version":"HPG5"},{"DeviceName":"VK000240GWJPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-3047574a5044","Version":"HPG5"},{"DeviceName":"VK000480GWJPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-3047574a5045","Version":"HPG5"},{"DeviceName":"VK000960GWJPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-3047574a5046","Version":"HPG5"},{"DeviceName":"VK001920GWJPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-3047574a5048","Version":"HPG5"},{"DeviceName":"VK003840GWJPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-3047574a504b","Version":"HPG5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000240GWJPD, VK000480GWJPE, VK000960GWJPF,V K001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK,MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Fixes a rare link loss issue and adds enhancements for drive reliability.</li>\n\t<li>After HPG5 firmware is downloaded to the drive, the new HPG5 firmware will be active on the drive.</li>\n\t<li>The new drive bootloader code will be activated after the next drive power cycle.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"23503184","datemodified":"2021-08-27T13:01:18","file_list":["/CP048444_BUILD_2.data","/CP048444.vmexe","/CP048444.vmexe64","/CP048444.vmfile","/CP048444_VMw.zip","/CP048444.xml","/payload.json","/CP048444_VMw.zip/index.xml","/CP048444_VMw.zip/vendor-index.xml","/CP048444_VMw.zip/metadata.zip","/CP048444_VMw.zip/vib20/CP048444/HPE_bootbank_CP048444_HPG5.2-7.0.0.15843807.vib","/CP048444_VMw.zip/metadata.zip/vendor-index.xml","/CP048444_VMw.zip/metadata.zip/vmware.xml","/CP048444_VMw.zip/metadata.zip/vibs/CP048444-2996869717332519316.xml","/CP048444_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048444_HPG5.2-7.0.0.15843807.xml"],"md5sum":"78b64245a76f92a646e9c8d940664801","name":"CP048444.zip","release":"2021-08-27T12:56:22","revision":"0","sha1sum":"189f334c34d0d19ed19ca5250efca56b32bf0f64","size":"22MB","target_guids":["4d2340a5-304b-3030-3234-3047574b564b","4d2340a5-304b-3030-3438-3047574a504e","4d2340a5-304b-3030-3936-3047574a5050","4d2340a5-304b-3130-3932-3047574a5051","562340a5-304b-3030-3234-3047574a5044","562340a5-304b-3030-3438-3047574a5045","562340a5-304b-3030-3936-3047574a5046","562340a5-304b-3130-3932-3047574a5048","562340a5-304b-3330-3834-3047574a504b"],"type_of_change":"2","version":"HPG5","vib_list":[{"name":"CP048444","version":"HPG5.2-7.0.0.15843807"}]}],"id":{"product":"261c2f9a8f584fd69c7ae5c1643322e4","version":"6a03900c138b4f959c1a87a6c43a7f2f"},"installation":{"command":"CP042736.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします。</li>\n\t<li>CPXXXXXX.vmexe(ESXi 6.7 &以前のバージョン)およびCPXXXXXX.vmexe64(ESXi 7.0)は、次のコマンドを使用して実行可能です:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod x CPXXXXXX.vmexe    または    chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPXXXXXX.vmexe(または)./CPXXXXXX.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor ESXi - VK000240GWJPD、VK000480GWJPE、VK000960GWJPF、VK001920GWJPH、VK003840GWJPK、MK000240GWKVK、MK000480GWJPN、MK000960GWJPPおよびMK001920GWJPQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MK001920GWJPQ","target_guid":"4d2340a5-304b-3130-3932-3047574a5051","type":"sata"},{"id":"MK000240GWKVK","target_guid":"4d2340a5-304b-3030-3234-3047574b564b","type":"sata"},{"id":"MK000480GWJPN","target_guid":"4d2340a5-304b-3030-3438-3047574a504e","type":"sata"},{"id":"MK000960GWJPP","target_guid":"4d2340a5-304b-3030-3936-3047574a5050","type":"sata"},{"id":"VK003840GWJPK","target_guid":"562340a5-304b-3330-3834-3047574a504b","type":"sata"},{"id":"VK001920GWJPH","target_guid":"562340a5-304b-3130-3932-3047574a5048","type":"sata"},{"id":"VK000960GWJPF","target_guid":"562340a5-304b-3030-3936-3047574a5046","type":"sata"},{"id":"VK000480GWJPE","target_guid":"562340a5-304b-3030-3438-3047574a5045","type":"sata"},{"id":"VK000240GWJPD","target_guid":"562340a5-304b-3030-3234-3047574a5044","type":"sata"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-10T14:51:07","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Fixes a rare link loss issue and adds enhancements for drive reliability.</li>\n\t<li>After HPG5 firmware is downloaded to the drive, the new HPG5 firmware will be active on the drive.</li>\n\t<li>The new drive bootloader code will be activated after the next drive power cycle.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us</a></li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Fixes a rare link loss issue and adds enhancements for drive reliability.</li>\n\t<li>After HPG5 firmware is downloaded to the drive, the new HPG5 firmware will be active on the drive.</li>\n\t<li>The new drive bootloader code will be activated after the next drive power cycle.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us</a></li>\n</ul>","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK001920GWJPQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GWJPH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000240GWKVK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWJPN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWJPP","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWJPE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWJPD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWJPF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GWJPK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK007680GWSXN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M52008G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-30475753584e","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: VK007680GWSXN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK007680GWSXN Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16485311","datemodified":"2021-08-27T09:15:41","file_list":["/CP048411_BUILD_2.data","/CP048411.vmexe","/CP048411.vmexe64","/CP048411.vmfile","/CP048411_VMw.zip","/CP048411.xml","/payload.json","/CP048411_VMw.zip/index.xml","/CP048411_VMw.zip/vendor-index.xml","/CP048411_VMw.zip/metadata.zip","/CP048411_VMw.zip/vib20/CP048411/HPE_bootbank_CP048411_HPG3.2-7.0.0.15843807.vib","/CP048411_VMw.zip/metadata.zip/vendor-index.xml","/CP048411_VMw.zip/metadata.zip/vmware.xml","/CP048411_VMw.zip/metadata.zip/vibs/CP048411--1582149894279847640.xml","/CP048411_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048411_HPG3.2-7.0.0.15843807.xml"],"md5sum":"2bacb92dc5bd6b448c0d37c732863e5b","name":"CP048411.zip","release":"2021-08-27T09:10:45","revision":"0","sha1sum":"0fbc8f3479d75fee310c700c7d6c331c6686d5e1","size":"15MB","target_guids":["562340a5-304b-3730-3638-30475753584e"],"type_of_change":"1","version":"HPG3","vib_list":[{"name":"CP048411","version":"HPG3.2-7.0.0.15843807"}]}],"id":{"product":"b4be4739aaa741bf83254d24ca921fd7","version":"b288152fd7da4fd6879888bc26790d51"},"installation":{"command":"CP040787.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>HP Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK007680GWSXN Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VK007680GWSXNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VK007680GWSXN","target_guid":"562340a5-304b-3730-3638-30475753584e","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T06:45:23","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Improved Product Quality and Reliability. Changed Cap Charge Timeout to 14 seconds from 4 seconds to provide additional time for cap charge in marginal power environment.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK007680GWSXN","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWEZB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757455a42","Version":"HPGG"},{"DeviceName":"VK000480GWEZC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757455a43","Version":"HPGG"},{"DeviceName":"VK000960GWEZD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757455a44","Version":"HPGG"},{"DeviceName":"VK001920GWEZE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757455a45","Version":"HPGG"},{"DeviceName":"MK000240GWEZF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3234-304757455a46","Version":"HPGG"},{"DeviceName":"MK000480GWEZH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757455a48","Version":"HPGG"},{"DeviceName":"MK000960GWEZK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757455a4b","Version":"HPGG"},{"DeviceName":"MK001920GWHRU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304757485255","Version":"HPGG"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000240GWEZB, VK000480GWEZC, VK000960GWEZD, VK001920GWEZE, MK000240GWEZF, MK000480GWEZH, MK000960GWEZK and MK001920GWHRU"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000240GWEZB、VK000480GWEZC、VK000960GWEZD、VK001920GWEZE、MK000240GWEZF、MK000480GWEZH、MK000960GWEZK、およびMK001920GWHRU"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online HDD/SSD&nbsp;Flash Component for VMware ESXi - VK000240GWEZB, VK000480GWEZC, VK000960GWEZD, VK001920GWEZE, MK000240GWEZF, MK000480GWEZH, MK000960GWEZK, and MK001920GWHRU Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGG<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGB<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPGB</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"16471974","datemodified":"2021-08-27T09:07:11","file_list":["/CP048406_BUILD_3.data","/CP048406.vmexe","/CP048406.vmexe64","/CP048406.vmfile","/CP048406_VMw.zip","/CP048406.xml","/payload.json","/CP048406_VMw.zip/index.xml","/CP048406_VMw.zip/vendor-index.xml","/CP048406_VMw.zip/metadata.zip","/CP048406_VMw.zip/vib20/CP048406/HPE_bootbank_CP048406_HPGG.3-7.0.0.15843807.vib","/CP048406_VMw.zip/metadata.zip/vendor-index.xml","/CP048406_VMw.zip/metadata.zip/vmware.xml","/CP048406_VMw.zip/metadata.zip/vibs/CP048406-8529612673242572727.xml","/CP048406_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048406_HPGG.3-7.0.0.15843807.xml"],"md5sum":"85228e322526dececf4488091e2df596","name":"CP048406.zip","release":"2021-08-27T09:02:35","revision":"0","sha1sum":"1e669fff47ab632824c7d51e32215ed3263f9088","size":"15MB","target_guids":["562340a5-304b-3030-3234-304757455a42","562340a5-304b-3030-3438-304757455a43","562340a5-304b-3030-3936-304757455a44","562340a5-304b-3130-3932-304757455a45","4d2340a5-304b-3030-3234-304757455a46","4d2340a5-304b-3030-3438-304757455a48","4d2340a5-304b-3030-3936-304757455a4b","4d2340a5-304b-3130-3932-304757485255"],"type_of_change":"1","version":"HPGG","vib_list":[{"name":"CP048406","version":"HPGG.3-7.0.0.15843807"}]}],"id":{"product":"3a33d0d2b6ca440681703cda5e638a33","version":"a48c574e364044f69f03cf3a36d2d1af"},"installation":{"command":"CP041318.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>HP Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK000240GWEZB, VK000480GWEZC, VK000960GWEZD, VK001920GWEZE, MK000240GWEZF, MK000480GWEZH, MK000960GWEZK and MK001920GWHRU Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VK000240GWEZB、 VK000480GWEZC、VK000960GWEZD、VK001920GWEZE、MK000240GWEZF、MK000480GWEZH、MK000960GWEZK および MK001920GWHRU ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MK001920GWHRU","target_guid":"4d2340a5-304b-3130-3932-304757485255","type":"sata"},{"id":"VK001920GWEZE","target_guid":"562340a5-304b-3130-3932-304757455a45","type":"sata"},{"id":"MK000240GWEZF","target_guid":"4d2340a5-304b-3030-3234-304757455a46","type":"sata"},{"id":"VK000240GWEZB","target_guid":"562340a5-304b-3030-3234-304757455a42","type":"sata"},{"id":"MK000480GWEZH","target_guid":"4d2340a5-304b-3030-3438-304757455a48","type":"sata"},{"id":"VK000480GWEZC","target_guid":"562340a5-304b-3030-3438-304757455a43","type":"sata"},{"id":"MK000960GWEZK","target_guid":"4d2340a5-304b-3030-3936-304757455a4b","type":"sata"},{"id":"VK000960GWEZD","target_guid":"562340a5-304b-3030-3936-304757455a44","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T03:58:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Improvements to Product Quality and Reliability.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK001920GWHRU","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000240GWEZF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWEZH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWEZC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GWEZE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWEZD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWEZK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWEZB","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6966344","datemodified":"2021-05-17T21:45:32","file_list":["/CP047843.vmexe","/CP047843.vmfile","/CP047843.xml","/README.txt"],"md5sum":"8272b9c72230a1b1c40be6401bef4608","name":"CP047843.zip","release":"2021-05-18T02:42:05","revision":"0","sha1sum":"87e192279a423a771efe540ffe4cee6ad9a237ca","size":"6MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021","vib_list":[]}],"id":{"product":"0efab16660ef48c2b6333da634ea3a4e","version":"84181410ffe3498e8a27067806d24e08"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component requires that the CRU driver be loaded before the component can run.<br />\nThe minimum CRU version for 5.1 is 5.0.3.9.<br />\nThe minimum CRU version for 5.5 is 5.5.4.1.<br />\nThe minimum CRU version for 6.0 is 6.0.8.<br />\nThe minimum CRU version for 6.5 is 6.5.8.<br />\nThe minimum CRU version for 6.7 is 6.7.10.<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>SPP Offline mode boots a special Linux OS environment, thus the Linux Components are used, not the VMware Components</li>\n</ul>\n\n<p><br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Download the appropriate SPP</li>\n\t<li>Add the component to the SPP</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run SUM</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps to complete the firmware update</li>\n\t<li>Refer to the SPP documentation for detailed instructions at:&nbsp; <a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Component ( CPxxxxxx.zip) in a temporary directory</li>\n\t<li>From the same directory, unzip the Component:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>To perform the standalone installation, execute the command:<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>Follow the directions given by the Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system for the firmware update to take effect</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、実行する前にCRUドライバーがロードされている必要があります。<br />\n5.1の最小CRUバージョンは5.0.3.9です。<br />\n5.5の最小CRUバージョンは5.5.4.1です。<br />\n6.0の最小CRUバージョンは6.0.8です。<br />\n6.5の最小CRUバージョンは6.5.8です。<br />\n6.7の最小CRUバージョンは6.7.10です。<br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMwareコンポーネントではなく、Linuxコンポーネントが用いられます</li>\n</ul>\n\n<p><br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします</li>\n\t<li>SPPにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします</li>\n\t<li>SUMを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います</li>\n\t<li>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>コンポーネント (CPxxxxxx.zip)を一時ディレクトリに置きます</li>\n\t<li>同じディレクトリからコンポーネントをunzipします:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>スタンドアロンのインストールを行うために、次のコマンドを実行します：<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>コンポーネントの指示に従います</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n\t<li>システムを再起動し、ファームウェアのアップデートを有効にします</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware - HPE ProLiant ML350 Gen9 (P92) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for VMware - HPE ProLiant ML350 Gen9（P92）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"5","minor":"1","name":"VMware vSphere 5.1","platform":"vmware_esx_server","sr":"OEM"},{"major":"5","minor":"5","name":"VMware vSphere 5.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-05T03:38:13","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"}],"sw_keys":[{"name":"P92","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 1Gb 2-port 363i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1523103C1989","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37CE15900215","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900216","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366i Communication Board","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521159000FF","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 369i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900247","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C337F","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C3380","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 560FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-10FB103C17D0","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C339E","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C17D1","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C8157","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 560SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-10FB103C17D3","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FC","Version":"10.54.7"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D2","Version":"10.54.4"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FD","Version":"10.54.7"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D1","Version":"10.54.4"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D315900219","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900217","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D215900218","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 561T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1528103C211A","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 561FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1528103C192D","Version":"1.2836.0"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This component contains utilities and firmware for the online upgrade of HPE Intel NIC firmware running under Microsoft Windows Server 2016, Windows Server 2019."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"13568856","datemodified":"2021-08-28T00:22:24","file_list":["cp047026.xml","cpqsetup.exe","for_Gen9/","for_Gen9/install.bat","for_Gen9/iqvw64e.cat","for_Gen9/iqvw64e.inf","for_Gen9/iqvw64e.sys","for_Gen9/uninstall.bat","FW/","FW/BootIMG.FLB","FW/BootIMG_FVL4HP.FLB","FW/hpesinglenvmconfig.txt","FW/HPE_1G_Adapter_VPD_MAP.txt","FW/HPE_361i_I350_2p_Cu_NCSI_1.61_WOL_8000106F.txt","FW/HPE_361T.txt","FW/HPE_361T_H65030-003_2.25_80001147.txt","FW/HPE_363i_I350_2p_KX_NCSI_LS_80000D00.txt","FW/HPE_366FLR_G41713-00x_80001148.txt","FW/HPE_366i_I350_4p_Cu_NCSI_1.61_00FF_1590_80000EBF.txt","FW/HPE_366i_I350_4p_Cu_NCSI_1.61_8000105E.txt","FW/HPE_366T_MAP.txt","FW/HPE_366T_Quad_H73104-00x_80001146.txt","FW/HPE_369i_88E1512_P01_88E1512_P23_NCSI_5p10_800027FB.bin","FW/HPE_40G_Adapter_562FLR-SFP_VPD_MAP.txt","FW/HPE_40G_Adapter_KR_VPD_MAP_FVL4HP.txt","FW/HPE_40G_Adapter_VPD_MAP.txt","FW/HPE_560FLR-SFP_2_port_G42955-0xx_2.69_80000838.txt","FW/HPE_561FLR-T_G74768-000_update_EDC_2.19_800005B6.bin","FW/HPE_561T_OCSD_G88062-000_E1_2.46_80000636.bin","FW/HPE_562FLR-SFP_DP_H47655-000_80009655.bin","FW/HPE_562FLR-T_B0_AT2_3p10_8000137D.bin","FW/HPE_562SFP_DP_H44490-000_800095AA.bin","FW/HPE_562T_B0_AT2_MCTP_3p10_8000137C.bin","FW/HPE_563i_KR_DP_800035C0.bin","FW/HPE_568i_Backplane_2x10G_P01_NCSI_5p10_800027FC.bin","FW/HPE_Apollo_PHY_Auto_Detect_NCSI_5p10_800027F8.bin","FW/HPE_DL160_PHY_Auto_Detect_P01_88E1514_P23_NCSI_5p10_800027FA.bin","FW/HPE_FVL_FPK_Adapter_LOM_568i_VPD_MAP.txt","FW/HPE_FVL_FPK_Adapter_LOM_VPD_MAP.txt","FW/HPE_SFX_OCSD_G43260-0xx.txt","FW/HPE_XG_Adapter_VPD_MAP.txt","FW/HPE_XG_SGVL_Adapter_VPD_MAP.txt","FW/hpnvmupdate.cfg","HPNVMUpdate.exe","install.bat","iqvsw64e.cat","iqvsw64e.inf","iqvsw64e.sys","ja/","ja/NICOFUT.chm","NICOFUT.chm","nvmupdate.bat","nvmupdatewin64e.dll","ofvpdfixW64e.exe","OnlineFWUpgrade.dll","payload.json","rfendfixW64e.exe","zh-CN/","zh-CN/NICOFUT.chm"],"md5sum":"4e0795b1e3b3aa309b11e95f0b46b72a","name":"cp047026.exe","release":"2021-08-28T00:13:22","revision":"0","sha1sum":"17034b806cebe0504513bbe3596bb9616dcdf627","size":"12MB","target_guids":["a6b1a447-382a-5a4f-8086-1523103C1989","a6b1a447-382a-5a4f-8086-37CE15900215","a6b1a447-382a-5a4f-8086-37D115900216","a6b1a447-382a-5a4f-8086-1521159000FF","a6b1a447-382a-5a4f-8086-37D115900247","a6b1a447-382a-5a4f-8086-1521103C337F","a6b1a447-382a-5a4f-8086-1521103C3380","a6b1a447-382a-5a4f-8086-10FB103C17D0","a6b1a447-382a-5a4f-8086-1521103C339E","a6b1a447-382a-5a4f-8086-1521103C17D1","a6b1a447-382a-5a4f-8086-1521103C8157","a6b1a447-382a-5a4f-8086-10FB103C17D3","a6b1a447-382a-5a4f-8086-1572103C22FC","a6b1a447-382a-5a4f-8086-1563159000D2","a6b1a447-382a-5a4f-8086-1572103C22FD","a6b1a447-382a-5a4f-8086-1563159000D1","a6b1a447-382a-5a4f-8086-37D315900219","a6b1a447-382a-5a4f-8086-37D115900217","a6b1a447-382a-5a4f-8086-37D215900218","a6b1a447-382a-5a4f-8086-1528103C211A","a6b1a447-382a-5a4f-8086-1528103C192D"],"type_of_change":"1","version":"5.2.5.0"}],"id":{"product":"be56d38accd045cca89d446f2db8440b","version":"f41883877f4148d8bee09164ee480bbe"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca94d0369","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel E1R Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5963c8f7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel E1R Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec090ca3ac","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel E1R Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec08dc7810","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecaf3c08f1","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3804451b","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecee44051c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2bead763","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec8a51872f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca9730c7d","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfc261833","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3bb214b3","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec45933bde","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixs Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2cbf818e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixs Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec507d6c9c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40eb Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec77fc8d87","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40eb Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfbeb7312","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel E1R Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecc6f71532","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec24ae2520","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40eb Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec619e0b4b","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecee44d472","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixs Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixt Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5c8e5025","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.1.197.0","description":"HPE Intel ixt Driver for Windows Server 2019 must be installed prior to this component"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation.</p>\n\n<p>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</p>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed. For more information about downgrade limitation, refer to the following Customer advisory:&nbsp;<br />\n\thttps://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00069764en_us</li>\n\t<li>AC Power Cycle is required after firmware installation for updates&nbsp;to take effect for the following network adapters:<br />\n\tHPE Ethernet 1Gb 2-port 368i Adapter<br />\n\tHPE Ethernet 1Gb 2-port 369i Adapter<br />\n\tHPE Ethernet 1Gb 2-port 368FLR-MMT Adapter<br />\n\tHPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter<br />\n\tHPE Ethernet 10Gb 2-port 568FLR-MMT Adapter</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel Online Firmware Upgrade Utility for Windows Server x64 Editions"},{"lang":"ja","x_late":"HPE Intelオンラインファームウェアアップグレードユーティリティ for Windows Server x64 Edition"}],"prerequisites":{"required_diskspace":{"size_kb":"4100"},"supported_devices":[{"dev":"1523","subdev":"1989","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1523103c1989","type":"pci","ven":"8086"},{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00FF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1521159000ff","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"1521","subdev":"337F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c337f","type":"pci","ven":"8086"},{"dev":"1521","subdev":"3380","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-1521103c3380","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"1521","subdev":"339E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c339e","type":"pci","ven":"8086"},{"dev":"1521","subdev":"17D1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c17d1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"8157","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c8157","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c211a","type":"pci","ven":"8086"},{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c192d","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product addresses an Upgrade issue for HPE Ethernet 10Gb 2-port 560SFP+ Adapter.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product no longer supports Windows Server 2012 R2.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"HPNVMUpdate.exe","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWTFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG07scHPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57544644","Version":"HPD8"},{"DeviceName":"MB012000JWTFC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG07scHPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57544643","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB014000JWTFD and MB012000JWTFC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online HDD/SSD&nbsp;Flash Component for VMware ESXi - MB014000JWTFD and MB012000JWTFC&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>This firmware release provides additional protection against command timeouts.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16274199","datemodified":"2021-08-26T09:46:42","file_list":["/CP049120_BUILD_3.data","/CP049120.vmexe","/CP049120.vmexe64","/CP049120.vmfile","/CP049120_VMw.zip","/CP049120.xml","/payload.json","/CP049120_VMw.zip/index.xml","/CP049120_VMw.zip/vendor-index.xml","/CP049120_VMw.zip/metadata.zip","/CP049120_VMw.zip/vib20/CP049120/HPE_bootbank_CP049120_HPD8.3-7.0.0.15843807.vib","/CP049120_VMw.zip/metadata.zip/vendor-index.xml","/CP049120_VMw.zip/metadata.zip/vmware.xml","/CP049120_VMw.zip/metadata.zip/vibs/CP049120--3776151776463870189.xml","/CP049120_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049120_HPD8.3-7.0.0.15843807.xml"],"md5sum":"d1672e1bc0c334e6005b79ef1407265d","name":"CP049120.zip","release":"2021-08-26T09:41:35","revision":"0","sha1sum":"e10bb335eb3c600e612250226aef791d5c5bf35a","size":"15MB","target_guids":["4d2340a5-3042-3431-3030-304a57544644","4d2340a5-3042-3231-3030-304a57544643"],"type_of_change":"1","version":"HPD8","vib_list":[{"name":"CP049120","version":"HPD8.3-7.0.0.15843807"}]}],"id":{"product":"33bf4058d2284d31ad166fd3619cf008","version":"2f92036415e94c98a8f41dda69c0a655"},"installation":{"command":"CP041025.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします。</li>\n\t<li>CPXXXXXX.vmexe(ESXi 6.7 &以前のバージョン)およびCPXXXXXX.vmexe64(ESXi 7.0)は、次のコマンドを使用して実行可能です:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod x CPXXXXXX.vmexe    または    chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPXXXXXX.vmexe(または)./CPXXXXXX.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB014000JWTFD and MB012000JWTFC  Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB014000JWTFDおよびMB012000JWTFCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB014000JWTFD","target_guid":"4d2340a5-3042-3431-3030-304a57544644","type":"sas"},{"id":"MB012000JWTFC","target_guid":"4d2340a5-3042-3231-3030-304a57544643","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T12:19:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This firmware release provides additional protection against command timeouts.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This firmware release provides additional protection against command timeouts.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB014000JWTFD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB012000JWTFC","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWJRQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a574a5251","Version":"HPD9"},{"DeviceName":"MB006000JWJRP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574a5250","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB008000JWJRQ and MB006000JWJRP"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB008000JWJRQおよびMB006000JWJRP"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB008000JWJRQ and MB006000JWJRP Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD8<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>This firmware release provides additional protection against command timeouts.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"4889667","datemodified":"2021-08-12T19:15:43","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-2.1/CP049131.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-2.1/TAMG06scHPD9.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049131.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049131.scexe"],"md5sum":"8b26ee950999964784d89702a21cedfb","name":"firmware-hdd-faf39e0ff7-HPD9-2.1.x86_64.rpm","release":"2021-08-12T19:03:04","revision":"0","sha1sum":"05875c4e901e4b5b17b6a485c67b1cb8baf07c48","size":"4MB","target_guids":["4d2340a5-3042-3830-3030-304a574a5251","4d2340a5-3042-3630-3030-304a574a5250"],"type_of_change":"1","version":"HPD9"}],"id":{"product":"fcf6b49416e1460393e2103c04483878","version":"f7e57b434f4046838ce3ec9f0ca319c3"},"installation":{"command":"CP040352.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB008000JWJRQ and MB006000JWJRP Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB008000JWJRQおよびMB006000JWJRPドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB008000JWJRQ","target_guid":"4d2340a5-3042-3830-3030-304a574a5251","type":"sas"},{"id":"MB006000JWJRP","target_guid":"4d2340a5-3042-3630-3030-304a574a5250","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T16:56:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This firmware release provides additional protection against command timeouts.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This firmware release provides additional protection against command timeouts.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000JWJRQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB006000JWJRP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter and mezzanine host bus adapters. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"4439330","datemodified":"2021-08-27T03:31:49","file_list":["./etc/dracut.conf.d/qla2xxx.conf","./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/qlgc-qla2xxx","./lib/modules/5.3.18-22-default/updates/qlgc-qla2xxx/qla2xxx.ko","./lib/modules/5.3.18-22-default/updates/qlgc-qla2xxx/tcm_qla2xxx.ko","./usr/share/smartupdate/qlgc-qla2xxx-kmp-default/component.xml"],"md5sum":"3f6357943ebd586bae75c3038679177a","name":"qlgc-qla2xxx-kmp-default-10.02.01.00.a14_k1_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-08-27T03:24:09","revision":"0","sha1sum":"fa48d89d8c928f7ae952853ced346855c7d3bc46","size":"4MB","target_guids":[],"type_of_change":"1","version":"10.02.01.00.a14-k1"}],"id":{"product":"10f2aa5229f34794a0aa5b83d35cd2b1","version":"0a1bf94003424543adccb59fd08e5e08"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh qlgc-qla2xxx-kmp-default-10.02.01.00.a14_k1_k5.3.18_53-1.sles15sp3.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete, the following message displays:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</p>\n\n<p>Rewrite of same Driver version has to be performed using &ndash;reinstall option</p>\n\n<p>Example: rpm &ndash;Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm &ndash;reinstall</p>\n\n<p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"SUSE Linux Enterprise Server 15 Service Pack 2 Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters and Mezzanine Host Bus Adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015D","subven":"1077","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015C","subven":"1077","target_guid":"","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-18T06:47:33","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to driver version 10.02.01.00.a14-k1</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"qlgc-qla2xxx-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VS000480KWDUP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannmK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3030-3438-304b57445550","Version":"HPK4"},{"DeviceName":"VS000960KWDUQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannmK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3030-3936-304b57445551","Version":"HPK4"},{"DeviceName":"MS000400KWDUR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannmK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3053-3030-3430-304b57445552","Version":"HPK4"},{"DeviceName":"MS000800KWDUT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannmK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3053-3030-3830-304b57445554","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VS000480KWDUP, VS000960KWDUQ, MS000400KWDUR and MS000800KWDUT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for Linux (x64) - VS000480KWDUP, VS000960KWDUQ, MS000400KWDUR&nbsp;and MS000800KWDUT Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p><strong>&nbsp; &nbsp; &nbsp;</strong> None</p>\n"}],"files":[{"bytes":"6820489","datemodified":"2021-07-25T12:35:45","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-95a2e5abcb-HPK4-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-95a2e5abcb-HPK4-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-95a2e5abcb-HPK4-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-95a2e5abcb-HPK4-6.1/CP048505.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-95a2e5abcb-HPK4-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-95a2e5abcb-HPK4-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-95a2e5abcb-HPK4-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-95a2e5abcb-HPK4-6.1/setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-95a2e5abcb-HPK4-6.1/spannmK4.rel","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048505.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048505.scexe"],"md5sum":"6ba8a73d8e07cbea437996bcddbc8d7b","name":"firmware-hdd-95a2e5abcb-HPK4-6.1.x86_64.rpm","release":"2021-07-25T12:23:05","revision":"0","sha1sum":"d52efe6b6660f8d2b081692bb680d47d87480465","size":"6MB","target_guids":["562340a5-3053-3030-3438-304b57445550","562340a5-3053-3030-3936-304b57445551","4d2340a5-3053-3030-3430-304b57445552","4d2340a5-3053-3030-3830-304b57445554"],"type_of_change":"1","version":"HPK4"}],"id":{"product":"19705487dac745ff98bd9969d9ff7a10","version":"5e3b10823f5741d399a66e8d96a9b527"},"installation":{"command":"CP040922.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left: 30pt;\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（.rpm拡張子の付いていないrpmファイル名）を実行します。</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left: 30pt;\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を解凍するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するには Service Pack for ProLiant から以下の手順に従ってください:</strong><br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン:</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64)  - VS000480KWDUP, VS000960KWDUQ, MS000400KWDUR and MS000800KWDUT Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - VS000480KWDUP、VS000960KWDUQ、MS000400KWDUR、およびMS000800KWDUTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VS000960KWDUQ","target_guid":"562340a5-3053-3030-3936-304b57445551","type":"nvme"},{"id":"VS000480KWDUP","target_guid":"562340a5-3053-3030-3438-304b57445550","type":"nvme"},{"id":"MS000400KWDUR","target_guid":"4d2340a5-3053-3030-3430-304b57445552","type":"nvme"},{"id":"MS000800KWDUT","target_guid":"4d2340a5-3053-3030-3830-304b57445554","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T05:51:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MS000800KWDUT","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MS000400KWDUR","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VS000480KWDUP","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VS000960KWDUQ","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000JFDSL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRNSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a4644534c","Version":"HPD4"},{"DeviceName":"MB4000JFDSN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRNSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a4644534e","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB2000JFDSL and MB4000JFDSN"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： MB2000JFDSL and MB4000JFDSN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - &nbsp;MB2000JFDSL and MB4000JFDSN Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4883262","datemodified":"2021-07-23T06:23:34","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-46fc43ab26-HPD4-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-46fc43ab26-HPD4-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-46fc43ab26-HPD4-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-46fc43ab26-HPD4-8.1/CP048158.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-46fc43ab26-HPD4-8.1/TTMRNSD4.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-46fc43ab26-HPD4-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-46fc43ab26-HPD4-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-46fc43ab26-HPD4-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-46fc43ab26-HPD4-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048158.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048158.scexe"],"md5sum":"75337d4d9d30e38f23430ba87a6aab38","name":"firmware-hdd-46fc43ab26-HPD4-8.1.x86_64.rpm","release":"2021-07-23T06:09:05","revision":"0","sha1sum":"86d96d2b02cc2e4f4dded742a156dd472a364707","size":"4MB","target_guids":["002340a5-4d00-3242-3030-304a4644534c","002340a5-4d00-3442-3030-304a4644534e"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"a583c05eda574560bf7c625d7e1d2b1c","version":"84e37f1969da4a13949b4ab32fb6da90"},"installation":{"command":"CP040290.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB2000JFDSL and MB4000JFDSN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB2000JFDSLおよびMB4000JFDSNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB2000JFDSL","target_guid":"002340a5-4d00-3242-3030-304a4644534c","type":"sas"},{"id":"MB4000JFDSN","target_guid":"002340a5-4d00-3442-3030-304a4644534e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T15:22:22","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JFDSN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB2000JFDSL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter and mezzanine host bus adapters. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"4443593","datemodified":"2021-08-27T03:31:52","file_list":["./etc/dracut.conf.d/qla2xxx.conf","./etc/udev/rules.d/99-qla2xxx.rules","./lib/modules/5.3.18-57-default","./lib/modules/5.3.18-57-default/updates","./lib/modules/5.3.18-57-default/updates/qlgc-qla2xxx","./lib/modules/5.3.18-57-default/updates/qlgc-qla2xxx/qla2xxx.ko","./lib/modules/5.3.18-57-default/updates/qlgc-qla2xxx/tcm_qla2xxx.ko","./lib/udev/qla2xxx_udev.sh","./usr/share/smartupdate/qlgc-qla2xxx-kmp-default/component.xml"],"md5sum":"5145787855a06af0157ea025bcf287f3","name":"qlgc-qla2xxx-kmp-default-10.02.01.00.a14_k1_k5.3.18_57-4.sles15sp3.x86_64.rpm","release":"2021-08-27T03:23:03","revision":"0","sha1sum":"321a37dc06585685365868e6d413ad0845a7b807","size":"4MB","target_guids":[],"type_of_change":"1","version":"10.02.01.00.a14-k1"}],"id":{"product":"ea2efd8eaf8d49e2b4bf0ce32cd253de","version":"c9ac3ed3f3974b8c9f98a395eb619e92"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh qlgc-qla2xxx-kmp-default-10.02.01.00.a14_k1_k5.3.18_53-1.sles15sp3.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete, the following message displays:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</p>\n\n<p>Rewrite of same Driver version has to be performed using &ndash;reinstall option</p>\n\n<p>Example: rpm &ndash;Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm &ndash;reinstall</p>\n\n<p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"SUSE Linux Enterprise Server 15 Service Pack 3 Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters and Mezzanine Host Bus Adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015D","subven":"1077","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015C","subven":"1077","target_guid":"","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-18T06:47:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to driver version 10.02.01.00.a14-k1</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"qlgc-qla2xxx-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWTSV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757545356","Version":"HPG6"},{"DeviceName":"VK000480GWTTA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757545441","Version":"HPG6"},{"DeviceName":"VK000960GWTTB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757545442","Version":"HPG6"},{"DeviceName":"VK001920GWTTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757545443","Version":"HPG6"},{"DeviceName":"VK003840GWTTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304757545444","Version":"HPG6"},{"DeviceName":"MK000480GWTTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757545448","Version":"HPG6"},{"DeviceName":"MK000960GWTTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-30475754544b","Version":"HPG6"},{"DeviceName":"MK001920GWTTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475754544c","Version":"HPG6"},{"DeviceName":"MK003840GWTTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475754544e","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000240GWTSV、VK000480GWTTA、VK000960GWTTB、VK001920GWTTC、VK003840GWTTD、MK000480GWTTH、MK000960GWTTK、MK001920GWTTL および MK003840GWTTN ドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and&nbsp;MK003840GWTTN Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5025946","datemodified":"2021-07-23T10:42:06","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG6-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG6-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG6-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG6-3.1/4IYRHPG6.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG6-3.1/CP048188.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG6-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG6-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG6-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG6-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048188.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048188.scexe"],"md5sum":"91b2a4db27604a6d4d9508a8cb440450","name":"firmware-hdd-c566d63ca0-HPG6-3.1.x86_64.rpm","release":"2021-07-23T10:30:07","revision":"0","sha1sum":"08d3a5f217584218c81d59204a7dfa80a86af041","size":"4MB","target_guids":["562340a5-304b-3030-3234-304757545356","562340a5-304b-3030-3438-304757545441","562340a5-304b-3030-3936-304757545442","562340a5-304b-3130-3932-304757545443","562340a5-304b-3330-3834-304757545444","4d2340a5-304b-3030-3438-304757545448","4d2340a5-304b-3030-3936-30475754544b","4d2340a5-304b-3130-3932-30475754544c","4d2340a5-304b-3330-3834-30475754544e"],"type_of_change":"1","version":"HPG6"}],"id":{"product":"c6a4f7a1c0f14173802a4263b3ee7551","version":"92ac47bc180d45248ad5a01b57912e75"},"installation":{"command":"CP040783.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VK000240GWTSV、VK000480GWTTA、VK000960GWTTB、VK001920GWTTC、VK003840GWTTD、MK000480GWTTH、MK000960GWTTK、MK001920GWTTLおよびMK003840GWTTNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VK003840GWTTD","target_guid":"562340a5-304b-3330-3834-304757545444","type":"sata"},{"id":"MK003840GWTTN","target_guid":"4d2340a5-304b-3330-3834-30475754544e","type":"sata"},{"id":"VK001920GWTTC","target_guid":"562340a5-304b-3130-3932-304757545443","type":"sata"},{"id":"MK001920GWTTL","target_guid":"4d2340a5-304b-3130-3932-30475754544c","type":"sata"},{"id":"VK000960GWTTB","target_guid":"562340a5-304b-3030-3936-304757545442","type":"sata"},{"id":"MK000960GWTTK","target_guid":"4d2340a5-304b-3030-3936-30475754544b","type":"sata"},{"id":"VK000480GWTTA","target_guid":"562340a5-304b-3030-3438-304757545441","type":"sata"},{"id":"MK000480GWTTH","target_guid":"4d2340a5-304b-3030-3438-304757545448","type":"sata"},{"id":"VK000240GWTSV","target_guid":"562340a5-304b-3030-3234-304757545356","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T08:13:26","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK003840GWTTD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWTTB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWTTA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GWTTC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWTSV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWTTH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK001920GWTTL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWTTK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK003840GWTTN","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Broadcom NetXtreme-E NICs running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Broadcom NetXtreme-E NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"316463","datemodified":"2021-01-14T07:13:59","file_list":["./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/bnxt_en.ko","./lib/modules/5.3.18-22-default/updates/drivers","./lib/modules/5.3.18-22-default/updates/drivers/infiniband","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/share/smartupdate/bnxt_en-kmp-default/component.xml"],"md5sum":"6fab2c585f1b17f3f7b917e35967cab6","name":"bnxt_en-kmp-default-1.10.2_k5.3.18_22-218.0.67.0.sles15sp2.x86_64.rpm","release":"2021-01-14T06:45:05","revision":"0","sha1sum":"b3347c82ac0e5bf5682803c25690f069aebdd3e5","size":"309KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ece34fd967"],"type_of_change":"0","version":"1.10.2-218.0.67.0"},{"bytes":"304978","datemodified":"2021-01-14T07:05:34","file_list":["./lib/modules/4.12.14-195-default","./lib/modules/4.12.14-195-default/updates","./lib/modules/4.12.14-195-default/updates/bnxt_en.ko","./lib/modules/4.12.14-195-default/updates/drivers","./lib/modules/4.12.14-195-default/updates/drivers/infiniband","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/share/smartupdate/bnxt_en-kmp-default/component.xml"],"md5sum":"be75b5ac2eb357caee75e85a57eb79d9","name":"bnxt_en-kmp-default-1.10.2_k4.12.14_195-218.0.67.0.sles15sp1.x86_64.rpm","release":"2021-01-14T06:45:05","revision":"0","sha1sum":"7e976c0db5e67cf82efed1393a2c1c7cc1f2ce4d","size":"297KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ece34fd967"],"type_of_change":"0","version":"1.10.2-218.0.67.0"}],"id":{"product":"2ed4fb56e81f45b0b8ae601a61b78e6c","version":"f4dc0a0dbb32404c84435b00ce283016"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation instructions.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE Broadcom NetXtreme-E ドライバー for SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>This product now not support user establishing connections using RDMA communication manager(CM) when Priority-based Flow Control (PFC) configured VLAN ID is 0</li>\n\t<li>This product now sets Maximum Transmission Unit(MTU) default value from firmware returned value</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>This product corrects an issue which offload is not happening on bond(vf and virtio) interface after the fail over with VF as the active slave</li>\n\t<li>This product corrects an issue which driver loading failed on kdump kernel.</li>\n\t<li>This product corrects an issue which RoCE driver causes input&ndash;output memory management unit(IOMMU) warnings</li>\n\t<li>This product corrects an issue which RoCE Link Aggregation (RoCE LAG) when Maximum Transmission Unit(MTU) was changed.</li>\n\t<li>This product corrects an issue which Link up failed after resuming from hibernation</li>\n\t<li>This product corrects an issue which Virtual Function RoCE driver causes Virtual Machine to be rebooted.</li>\n\t<li>This product corrects an issue which HPSUM selects driver for SUSE Linux Enterprise Server 15 while SPP deployment running with SUSE Linux Enterprise Server 15 Service Pack 1 platform.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>This product now supports SUSE Linux Enterprise Server 15 Service Pack 2</li>\n\t<li>This product now supports PAM4 speeds information in&nbsp;ethtool tools&nbsp;</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where system crashed on doing driver unload load in loop when running broadcast traffic</li>\n\t<li>This product addresses an issue where bnxt_en module crashes with NULL pointer deference before ifup(bring up network interface)</li>\n\t<li>This product addresses an issue where kernel panic after PCIe AER(Advanced Error Reporting) device recovery successful</li>\n\t<li>This product addresses an issue where bnxt_en crashes with NULL pointer dereference when enabling SRIOV</li>\n\t<li>This product correct an error where ethtool -S tx_bytes and rx_bytes counter values far exceed actual values</li>\n\t<li>This product correct an error message when querying hwmon temperature on VF via sysfs</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"bnxt_en-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"bnxt_en-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"bnxt_en-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"bnxt_en-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK003840GWHTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M51004G8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-304757485445","Version":"HPG8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MK003840GWHTE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MK003840GWHTE Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG6<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG6</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"16422286","datemodified":"2021-08-27T05:43:42","file_list":["/CP048383_BUILD_2.data","/CP048383.vmexe","/CP048383.vmexe64","/CP048383.vmfile","/CP048383_VMw.zip","/CP048383.xml","/payload.json","/CP048383_VMw.zip/index.xml","/CP048383_VMw.zip/vendor-index.xml","/CP048383_VMw.zip/metadata.zip","/CP048383_VMw.zip/vib20/CP048383/HPE_bootbank_CP048383_HPG8.2-7.0.0.15843807.vib","/CP048383_VMw.zip/metadata.zip/vendor-index.xml","/CP048383_VMw.zip/metadata.zip/vmware.xml","/CP048383_VMw.zip/metadata.zip/vibs/CP048383--1835485894284196433.xml","/CP048383_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048383_HPG8.2-7.0.0.15843807.xml"],"md5sum":"5e49356c4c3078b6815591ca66f205f1","name":"CP048383.zip","release":"2021-08-27T05:38:27","revision":"0","sha1sum":"95fb892d316b007de3e3eec9091b3d5c3b05f961","size":"15MB","target_guids":["4d2340a5-304b-3330-3834-304757485445"],"type_of_change":"1","version":"HPG8","vib_list":[{"name":"CP048383","version":"HPG8.2-7.0.0.15843807"}]}],"id":{"product":"41769df117cd4b93b1e9b45d5d971451","version":"2e2a9ef149c247129fe6913965ad4f92"},"installation":{"command":"CP041321.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>HP Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MK003840GWHTE Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - MK003840GWHTEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T09:39:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Improvements to Product Quality and Reliability.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK003840GWHTE","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001000KWJSE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3030-304b574a5345","Version":"4ICDHPK1"},{"DeviceName":"VO002000KWJSF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3230-3030-304b574a5346","Version":"4ICDHPK1"},{"DeviceName":"VO004000KWJSH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3430-3030-304b574a5348","Version":"4ICDHPK1"},{"DeviceName":"VT004000KWJSU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3054-3430-3030-304b574a5355","Version":"4ICDHPK1"},{"DeviceName":"MO001600KWJSN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b574a534e","Version":"4ICDHPK1"},{"DeviceName":"MO003200KWJSQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b574a5351","Version":"4ICDHPK1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO001000KWJSE, VO002000KWJSF, VO004000KWJSH, VT004000KWJSU, MO001600KWJSN and MO003200KWJSQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;NVMe SSD&nbsp;Flash Component for Windows&nbsp;(x64) - &nbsp;VO001000KWJSE, VO002000KWJSF, VO004000KWJSH, VT004000KWJSU, MO001600KWJSN and MO003200KWJSQ Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>This firmware corrects the potential for a drive to become disabled and nonfunctional during certain conditions or workloads.</li>\n\t<li>After the drive is upgraded to firmware version HPK1, it cannot be downgraded to firmware version HPK0.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3109280","datemodified":"2021-07-24T10:11:16","file_list":["4ICDHPK1.rel","cp048438.xml","cpqsetup.exe","payload.json","setup.dll"],"md5sum":"6bafd245043dc83af04d3bb361b7e655","name":"cp048438.exe","release":"2021-07-24T10:04:04","revision":"0","sha1sum":"95eb3f59b469b07a993bf8da32a2d97cfc6e64ea","size":"2MB","target_guids":["562340a5-304f-3130-3030-304b574a5345","562340a5-304f-3230-3030-304b574a5346","562340a5-304f-3430-3030-304b574a5348","562340a5-3054-3430-3030-304b574a5355","4d2340a5-304f-3130-3630-304b574a534e","4d2340a5-304f-3330-3230-304b574a5351"],"type_of_change":"2","version":"4ICDHPK1"}],"id":{"product":"73c467f62ccd4e6c837bbb93fd6013e1","version":"f1f3d7bd516e4e81b2e24d54bb4e298b"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) - VO001000KWJSE, VO002000KWJSF, VO004000KWJSH, VT004000KWJSU, MO001600KWJSN and MO003200KWJSQ Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - VO001000KWJSE、VO002000KWJSF、VO004000KWJSH、VT004000KWJSU、MO001600KWJSN、およびMO003200KWJSQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MO003200KWJSQ","target_guid":"4d2340a5-304f-3330-3230-304b574a5351","type":"nvme"},{"id":"VO002000KWJSF","target_guid":"562340a5-304f-3230-3030-304b574a5346","type":"nvme"},{"id":"MO001600KWJSN","target_guid":"4d2340a5-304f-3130-3630-304b574a534e","type":"nvme"},{"id":"VO001000KWJSE","target_guid":"562340a5-304f-3130-3030-304b574a5345","type":"nvme"},{"id":"VT004000KWJSU","target_guid":"562340a5-3054-3430-3030-304b574a5355","type":"nvme"},{"id":"VO004000KWJSH","target_guid":"562340a5-304f-3430-3030-304b574a5348","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-10T11:20:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows 2019.</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>This firmware corrects the potential for a drive to become disabled and nonfunctional during certain conditions or workloads.</li>\n\t<li>After the drive is upgraded to firmware version HPK1, it cannot be downgraded to firmware version HPK0.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This firmware corrects the potential for a drive to become disabled and nonfunctional during certain conditions or workloads.</li>\n\t<li>After the drive is upgraded to firmware version HPK1, it cannot be downgraded to firmware version HPK0.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO001000KWJSE","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO002000KWJSF","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO001600KWJSN","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO004000KWJSH","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO003200KWJSQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VT004000KWJSU","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VS000480KWDUP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannmK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3030-3438-304b57445550","Version":"HPK4"},{"DeviceName":"VS000960KWDUQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannmK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3030-3936-304b57445551","Version":"HPK4"},{"DeviceName":"MS000400KWDUR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannmK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3053-3030-3430-304b57445552","Version":"HPK4"},{"DeviceName":"MS000800KWDUT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannmK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3053-3030-3830-304b57445554","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VS000480KWDUP, VS000960KWDUQ, MS000400KWDUR and MS000800KWDUT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for&nbsp;Windows (x64) -&nbsp;VS000480KWDUP, VS000960KWDUQ, MS000400KWDUR and MS000800KWDUT Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4922960","datemodified":"2021-07-24T10:58:15","file_list":["cp048487.xml","cpqsetup.exe","payload.json","setup.dll","spannmK4.rel"],"md5sum":"991c92dcbe92ab604b22ea64f3738527","name":"cp048487.exe","release":"2021-07-24T10:51:04","revision":"0","sha1sum":"3c1bcacf6a3ea79e3d39b29e33bfaee3fd992a58","size":"4MB","target_guids":["562340a5-3053-3030-3438-304b57445550","562340a5-3053-3030-3936-304b57445551","4d2340a5-3053-3030-3430-304b57445552","4d2340a5-3053-3030-3830-304b57445554"],"type_of_change":"1","version":"HPK4"}],"id":{"product":"537734d235b44d80ac3623e8cb9c5d5b","version":"77e6a06222c541c1bff0465cb914ba65"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) -  VS000480KWDUP, VS000960KWDUQ, MS000400KWDUR and MS000800KWDUT Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - VS000480KWDUP、VS000960KWDUQ、MS000400KWDUR、およびMS000800KWDUTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MS000400KWDUR","target_guid":"4d2340a5-3053-3030-3430-304b57445552","type":"nvme"},{"id":"VS000960KWDUQ","target_guid":"562340a5-3053-3030-3936-304b57445551","type":"nvme"},{"id":"MS000800KWDUT","target_guid":"4d2340a5-3053-3030-3830-304b57445554","type":"nvme"},{"id":"VS000480KWDUP","target_guid":"562340a5-3053-3030-3438-304b57445550","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-14T08:29:22","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MS000800KWDUT","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MS000400KWDUR","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VS000480KWDUP","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VS000960KWDUQ","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000400JWFWN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a5746574e","Version":"HPD5"},{"DeviceName":"MO000800JWFWP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57465750","Version":"HPD5"},{"DeviceName":"MO001600JWFWQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57465751","Version":"HPD5"},{"DeviceName":"MO003200JWFWR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57465752","Version":"HPD5"},{"DeviceName":"MO000960JWFWT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3936-304a57465754","Version":"HPD5"},{"DeviceName":"MO001920JWFWU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a57465755","Version":"HPD5"},{"DeviceName":"MO003840JWFWV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3834-304a57465756","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MO000400JWFWN, MO000800JWFWP, MO001600JWFWQ, MO003200JWFWR, MO000960JWFWT, MO001920JWFWU and MO003840JWFWV"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MO000400JWFWN、MO000800JWFWP、MO001600JWFWQ、MO003200JWFWR、MO000960JWFWT、MO001920JWFWUおよびMO003840JWFWV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MO000400JWFWN, MO000800JWFWP, MO001600JWFWQ, MO003200JWFWR, MO000960JWFWT, MO001920JWFWU and MO003840JWFWV&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4794667","datemodified":"2021-07-23T07:59:48","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b8a60fbe9a-HPD5-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-b8a60fbe9a-HPD5-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b8a60fbe9a-HPD5-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b8a60fbe9a-HPD5-5.1/CP048182.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b8a60fbe9a-HPD5-5.1/TAPM4VVEHPD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-b8a60fbe9a-HPD5-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b8a60fbe9a-HPD5-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b8a60fbe9a-HPD5-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b8a60fbe9a-HPD5-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048182.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048182.scexe"],"md5sum":"b5bd338396cdbb8e20f7710f1bc0de24","name":"firmware-hdd-b8a60fbe9a-HPD5-5.1.x86_64.rpm","release":"2021-07-23T07:46:08","revision":"0","sha1sum":"eb2d52c9cd1e887f75fd7410c7fec3cb28a90c01","size":"4MB","target_guids":["4d2340a5-304f-3030-3430-304a5746574e","4d2340a5-304f-3030-3830-304a57465750","4d2340a5-304f-3130-3630-304a57465751","4d2340a5-304f-3330-3230-304a57465752","4d2340a5-304f-3030-3936-304a57465754","4d2340a5-304f-3130-3932-304a57465755","4d2340a5-304f-3330-3834-304a57465756"],"type_of_change":"1","version":"HPD5"}],"id":{"product":"0621549b347544c1869a7fcad2fb7ecf","version":"82264eeba1a94c428c28f18f331f862a"},"installation":{"command":"CP041423.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MO000400JWFWN, MO000800JWFWP, MO001600JWFWQ, MO003200JWFWR, MO000960JWFWT, MO001920JWFWU and MO003840JWFWV Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux(x64)-MO000400JWFWN、MO000800JWFWP、MO001600JWFWQ、MO003200JWFWR、MO000960JWFWT、MO001920JWFWUおよびMO003840JWFWVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MO003200JWFWR","target_guid":"4d2340a5-304f-3330-3230-304a57465752","type":"sas"},{"id":"MO001920JWFWU","target_guid":"4d2340a5-304f-3130-3932-304a57465755","type":"sas"},{"id":"MO001600JWFWQ","target_guid":"4d2340a5-304f-3130-3630-304a57465751","type":"sas"},{"id":"MO000960JWFWT","target_guid":"4d2340a5-304f-3030-3936-304a57465754","type":"sas"},{"id":"MO000800JWFWP","target_guid":"4d2340a5-304f-3030-3830-304a57465750","type":"sas"},{"id":"MO000400JWFWN","target_guid":"4d2340a5-304f-3030-3430-304a5746574e","type":"sas"},{"id":"MO003840JWFWV","target_guid":"4d2340a5-304f-3330-3834-304a57465756","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T20:44:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MO003840JWFWV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200JWFWR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000400JWFWN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001920JWFWU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600JWFWQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000960JWFWT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800JWFWP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000JFDSL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRNSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a4644534c","Version":"HPD4"},{"DeviceName":"MB4000JFDSN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRNSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a4644534e","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB2000JFDSL and MB4000JFDSN"},{"lang":"ja","x_late":"このSmartコンポーネントが、ファームウェアを提供できるドライブモデル： MB2000JFDSL and MB4000JFDSN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;MB2000JFDSL and MB4000JFDSN Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16230274","datemodified":"2021-08-26T19:03:41","file_list":["/CP048347_BUILD_2.data","/CP048347.vmexe","/CP048347.vmexe64","/CP048347.vmfile","/CP048347_VMw.zip","/CP048347.xml","/payload.json","/CP048347_VMw.zip/index.xml","/CP048347_VMw.zip/vendor-index.xml","/CP048347_VMw.zip/metadata.zip","/CP048347_VMw.zip/vib20/CP048347/HPE_bootbank_CP048347_HPD4.2-7.0.0.15843807.vib","/CP048347_VMw.zip/metadata.zip/vendor-index.xml","/CP048347_VMw.zip/metadata.zip/vmware.xml","/CP048347_VMw.zip/metadata.zip/vibs/CP048347--2948227851561811756.xml","/CP048347_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048347_HPD4.2-7.0.0.15843807.xml"],"md5sum":"152c997edc171e0380b59f2eafa1d89c","name":"CP048347.zip","release":"2021-08-26T18:58:39","revision":"0","sha1sum":"203f2f41b88577da3c32c46c761aae81795a65cb","size":"15MB","target_guids":["002340a5-4d00-3242-3030-304a4644534c","002340a5-4d00-3442-3030-304a4644534e"],"type_of_change":"1","version":"HPD4","vib_list":[{"name":"CP048347","version":"HPD4.2-7.0.0.15843807"}]}],"id":{"product":"8e3928e62813480eab785be8f1d93fd8","version":"2fa0ab4d2d5342278be03969a9f45672"},"installation":{"command":"CP040513.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB2000JFDSL and MB4000JFDSN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB2000JFDSLおよびMB4000JFDSNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB2000JFDSL","target_guid":"002340a5-4d00-3242-3030-304a4644534c","type":"sas"},{"id":"MB4000JFDSN","target_guid":"002340a5-4d00-3442-3030-304a4644534e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-06T19:49:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JFDSN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB2000JFDSL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB8000GFECR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRPTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3842-3030-304746454352","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB8000GFECR Drives "},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB8000GFECRドライブ "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp; MB8000GFECR Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPG5</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPG5<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5402840","datemodified":"2021-07-23T07:49:03","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-6d922fc9a8-HPG6-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-6d922fc9a8-HPG6-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-6d922fc9a8-HPG6-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6d922fc9a8-HPG6-6.1/CP048174.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-6d922fc9a8-HPG6-6.1/SMKRPTG6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-6d922fc9a8-HPG6-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6d922fc9a8-HPG6-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-6d922fc9a8-HPG6-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-6d922fc9a8-HPG6-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048174.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048174.scexe"],"md5sum":"bda5e8191f929ac1bbc9224a360f612e","name":"firmware-hdd-6d922fc9a8-HPG6-6.1.x86_64.rpm","release":"2021-07-23T07:34:09","revision":"0","sha1sum":"7224e89fa244f5b1ba32a69379caf6b59047bf81","size":"5MB","target_guids":["002340a5-4d00-3842-3030-304746454352"],"type_of_change":"1","version":"HPG6"}],"id":{"product":"d9c3a00a773f42a180ec8a2979413243","version":"d33f1f14f45f46718b152e04efb24b35"},"installation":{"command":"CP040293.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB8000GFECR Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB8000GFECRドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB8000GFECR","target_guid":"002340a5-4d00-3842-3030-304746454352","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T20:05:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB8000GFECR","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GVYZB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPETG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304756595a42","Version":"HPG4"},{"DeviceName":"MB4000GVYZA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPETG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304756595a41","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB6000GVYZB and MB4000GVYZA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB6000GVYZB and MB4000GVYZA Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3526648","datemodified":"2021-07-25T15:40:30","file_list":["cp048613.xml","cpqsetup.exe","payload.json","setup.dll","SMBPETG4.rel"],"md5sum":"b1a0cde0973c2c8a425a06adca91e9f5","name":"cp048613.exe","release":"2021-07-25T15:33:06","revision":"0","sha1sum":"a31d2adb2e2af7752361956d871366449fae7f3d","size":"3MB","target_guids":["002340a5-4d00-3642-3030-304756595a42","002340a5-4d00-3442-3030-304756595a41"],"type_of_change":"1","version":"HPG4"}],"id":{"product":"91ee236bfbbc43019f9a1a0183e7fcbd","version":"0261662d06d5477f8804731dce23ff8d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB6000GVYZB and MB4000GVYZA Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows(x64) - MB6000GVYZBおよびMB4000GVYZAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB4000GVYZA","target_guid":"002340a5-4d00-3442-3030-304756595a41","type":"sata"},{"id":"MB6000GVYZB","target_guid":"002340a5-4d00-3642-3030-304756595a42","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T11:48:11","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000GVYZB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB4000GVYZA","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6978405","datemodified":"2021-05-17T23:17:30","file_list":["/CP047837.vmexe","/CP047837.vmfile","/CP047837.xml","/README.txt"],"md5sum":"f32e7b1f5af3417bf651f7c6e029163f","name":"CP047837.zip","release":"2021-05-18T04:14:08","revision":"0","sha1sum":"ae2e7acbc8c61383e8f40a72211bebdf91241949","size":"6MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021","vib_list":[]}],"id":{"product":"fc0ed88941764df9b650bfbb2dbeee2a","version":"562a5978fdf44092b18f650fb5c72b2d"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component requires that the CRU driver be loaded before the component can run.<br />\nThe minimum CRU version for 5.1 is 5.0.3.9.<br />\nThe minimum CRU version for 5.5 is 5.5.4.1.<br />\nThe minimum CRU version for 6.0 is 6.0.8.<br />\nThe minimum CRU version for 6.5 is 6.5.8.<br />\nThe minimum CRU version for 6.7 is 6.7.10.<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>SPP Offline mode boots a special Linux OS environment, thus the Linux Components are used, not the VMware Components</li>\n</ul>\n\n<p><br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Download the appropriate SPP</li>\n\t<li>Add the component to the SPP</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run SUM</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps to complete the firmware update</li>\n\t<li>Refer to the SPP documentation for detailed instructions at:&nbsp; <a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Component ( CPxxxxxx.zip) in a temporary directory</li>\n\t<li>From the same directory, unzip the Component:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>To perform the standalone installation, execute the command:<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>Follow the directions given by the Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system for the firmware update to take effect</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、実行する前にCRUドライバーがロードされている必要があります。<br />\n5.1の最小CRUバージョンは5.0.3.9です。<br />\n5.5の最小CRUバージョンは5.5.4.1です。<br />\n6.0の最小CRUバージョンは6.0.8です。<br />\n6.5の最小CRUバージョンは6.5.8です。<br />\n6.7の最小CRUバージョンは6.7.10です。<br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMwareコンポーネントではなく、Linuxコンポーネントが用いられます</li>\n</ul>\n\n<p><br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします</li>\n\t<li>SPPにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします</li>\n\t<li>SUMを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います</li>\n\t<li>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>コンポーネント (CPxxxxxx.zip)を一時ディレクトリに置きます</li>\n\t<li>同じディレクトリからコンポーネントをunzipします:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>スタンドアロンのインストールを行うために、次のコマンドを実行します：<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>コンポーネントの指示に従います</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n\t<li>システムを再起動し、ファームウェアのアップデートを有効にします</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware - HPE ProLiant DL160 Gen9/DL180 Gen9 (U20) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for VMware - HPE ProLiant DL160 Gen9/DL180 Gen9 (U20) サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"5","minor":"1","name":"VMware vSphere 5.1","platform":"vmware_esx_server","sr":"OEM"},{"major":"5","minor":"5","name":"VMware vSphere 5.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-05T03:27:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"}],"sw_keys":[{"name":"U20","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the vxn driver for HPE Blade Intel ixn 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Microsoft Windows Server 2019で動作しているHPE Blade Intel ixt 10 Gigabit Ethernet NIC用のvxnドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"838056","datemodified":"2021-08-18T16:12:14","file_list":["cp049076.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll","vxn68x64.cat","vxn68x64.din","vxn68x64.inf","vxn68x64.sys","vxnmsg.dll"],"md5sum":"ca470ccb2befa959c31eb4376d937ecf","name":"cp049076.exe","release":"2021-08-18T15:58:21","revision":"0","sha1sum":"5f13eb20af7b137b95d50de3dc620bff11889a60","size":"818KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec40e07a7c"],"type_of_change":"0","version":"2.1.191.0"}],"id":{"product":"266dae77506e4f72bfe8d5ce5b7da6ff","version":"ed31c9f0b77b455d82428d11c41b9522"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Intel vxn Driver for Windows Server 2019"},{"lang":"ja","x_late":"HPE Blade Intel vxnドライバー for Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"10ED","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c18d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d2","type":"pci","ven":"8086"},{"dev":"152E","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-03T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product is updated to maintain compatibility with updated Windows installation library vxnmsg.dll.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports the&nbsp;HPE ProLiant BL660c Gen9 Server.&nbsp;</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"vxn68x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800095","languages":[{"lang":"fr","x_late":"Logiciel - Réseau"},{"lang":"en","x_late":"Software - Network"},{"lang":"cn","x_late":"软件 - 网络"},{"lang":"tw","x_late":"軟體 ─ 網路"},{"lang":"de","x_late":"Software - Netzwerk"},{"lang":"ko","x_late":"소프트웨어 - 네트워크"},{"lang":"it","x_late":"Software - Rete"},{"lang":"ja","x_late":"ソフトウェア - ネットワーク"},{"lang":"es","x_late":"Software - Red"}]}],"description":[{"lang":"tw","x_late":"此代理程式會從執行 Linux x86_64 平台的 HPE ProLiant 伺服器內受支援的 Intel 網路配接卡擷取感測器與健康狀況資料。"},{"lang":"en","x_late":"This agent extracts sensor and health data from supported Intel network adapters in HPE ProLiant servers running Linux x86_64 platforms."},{"lang":"ko","x_late":"이 에이전트는 Linux x86_64 플랫폼을 실행하는 HPE ProLiant 서버에서 지원되는 Intel 네트워크 어댑터로부터 센서 및 상태 데이터를 추출합니다."},{"lang":"cn","x_late":"该代理可在运行 Linux x86_64 平台的 HPE ProLiant 服务器中从支持的英特尔网络适配器解压传感器和状态数据。"},{"lang":"ja","x_late":"このエージェントは、Linux x86_64プラットフォームを実行しているHPE ProLiantサーバーでサポートされているIntelネットワークアダプターから、センサーおよびヘルスのデータを抽出します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"57711","datemodified":"2019-11-06T08:59:31","file_list":["./etc/init.d/ocsbbd","./usr/lib/ocsbbd/ocsbbd.rhel","./usr/lib/ocsbbd/ocsbbd.sles","./usr/sbin/ocsbbd","./usr/share/man/man8/ocsbbd.8.gz","./usr/share/smartupdate/hp-ocsbbd/component.xml"],"md5sum":"a67b0a829f7cb1c475953576533e8487","name":"hp-ocsbbd-1.1.85.0-1.x86_64.rpm","release":"2020-03-09T00:00:00","revision":"1","sha1sum":"1658b99d19c1905190cf8dfa4cf02d78440c0b3a","size":"56KB","target_guids":[],"type_of_change":"0","version":"1.1.85.0-1"}],"id":{"product":"3129a8bb92a043939b7bf306836723ed","version":"58e5417a5fbc4932b7450bf655ca2fbb"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download hp-ocsbbd-1.1.85.0-1.x86_64.txt to view installation instructions.</p>\n"},{"lang":"ja","x_late":"<p>インストール手順を確認するには、hp-ocsbbd-1.1.85.0-1.x86_64.txtをダウンロードしてください。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 HPE ProLiant 網路配接卡的 Intel Active Health System 代理程式 (適用於 Linux x86_64)"},{"lang":"en","x_late":"Intel Active Health System Agent for HPE ProLiant Network Adapters for Linux x86_64"},{"lang":"ko","x_late":"HPE 프로라이언트 네트워크 어댑터용 Intel Active Health System Agent(Linux x86_64)"},{"lang":"cn","x_late":"适用于采用 Linux x86_64 的 HPE ProLiant 网络适配器的 Intel Active Health System 代理"},{"lang":"ja","x_late":"HPE ProLiantネットワークアダプター for Linux x86_64用Intel Active Health Systemエージェント"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1521","subdev":"2226","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"1521","subdev":"337F","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"1523","subdev":"1989","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"1521","subdev":"339E","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"1521","subdev":"17D1","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"1523","subdev":"339F","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"1521","subdev":"8157","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-12-03T14:01:01","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>SUM no longer attempts to install this product on Gen10 servers, which this product&nbsp;does not support.</p>\n","latest_fixes_x_late":"<p>This product fixes an issue that it takes long time to boot-up server due to ocsbbd service.</p>\n"},{"curr_enhancements_x_late":"<p>SUM no longer attempts to install this product on Gen10 servers, which this product&nbsp;does not support.</p>\n","curr_fixes_x_late":"<p>This product fixes an issue that it takes long time to boot-up server due to ocsbbd service.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"}],"sw_keys":[{"name":"hp-ocsbbd","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000JEFRB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVNGSD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-304a45465242","Version":"HPD9"},{"DeviceName":"MM2000JEFRC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVNGSD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-324d-3030-304a45465243","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MM1000JEFRB and MM2000JEFRC"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MM1000JEFRBおよびMM2000JEFRC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MM1000JEFRB and MM2000JEFRC Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD7<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"17366085","datemodified":"2021-08-27T06:58:58","file_list":["/CP048391_BUILD_2.data","/CP048391.vmexe","/CP048391.vmexe64","/CP048391.vmfile","/CP048391_VMw.zip","/CP048391.xml","/payload.json","/CP048391_VMw.zip/index.xml","/CP048391_VMw.zip/vendor-index.xml","/CP048391_VMw.zip/metadata.zip","/CP048391_VMw.zip/vib20/CP048391/HPE_bootbank_CP048391_HPD9.2-7.0.0.15843807.vib","/CP048391_VMw.zip/metadata.zip/vendor-index.xml","/CP048391_VMw.zip/metadata.zip/vmware.xml","/CP048391_VMw.zip/metadata.zip/vibs/CP048391--8288305502192072914.xml","/CP048391_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048391_HPD9.2-7.0.0.15843807.xml"],"md5sum":"8d9f061fa4c837e6fa9fd0d0b76ffc68","name":"CP048391.zip","release":"2021-08-27T06:53:33","revision":"0","sha1sum":"507cf7b0622801036b658840b4deaf100c6a99be","size":"16MB","target_guids":["002340a5-4d00-314d-3030-304a45465242","002340a5-4d00-324d-3030-304a45465243"],"type_of_change":"1","version":"HPD9","vib_list":[{"name":"CP048391","version":"HPD9.2-7.0.0.15843807"}]}],"id":{"product":"6f1e3dc0362445eba42c38fd34e5d638","version":"6d32d43ca1bf4a7c807c526131c46258"},"installation":{"command":"CP042542.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - MM1000JEFRB and MM2000JEFRC Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MM1000JEFRBおよびMM2000JEFRCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MM1000JEFRB","target_guid":"002340a5-4d00-314d-3030-304a45465242","type":"sas"},{"id":"MM2000JEFRC","target_guid":"002340a5-4d00-324d-3030-304a45465243","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T11:40:55","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MM2000JEFRC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MM1000JEFRB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]},{"key":"7800374","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"en","x_late":"This package contains the kit to provide support for Smart SAN on QLogic fibre channel host bus adapters on Windows 64 bit operating systems."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1568952","datemodified":"2021-08-27T04:38:34","file_list":["cp048718.xml","cpqsetup.exe","cp_data.xml","get_ss_status.bat","QlSmartSANInstaller.dll","QLSMARTSANVer.exe","qsmartsan_cfg_cn.xml","qsmartsan_cfg_en.xml","qsmartsan_cfg_ja.xml","SmartSanCfg_x64.exe","SmartSAN_Readme.txt","ss_disable.bat","ss_enable.bat"],"md5sum":"87a900c3625273a50b535c00dc323471","name":"cp048718.exe","release":"2021-08-27T04:36:05","revision":"0","sha1sum":"1f7c6f6ffd723beb8afdfca94506c7ec710794e9","size":"1MB","target_guids":[],"type_of_change":"0","version":"1.0.0.1"}],"id":{"product":"8924205a8291483893f13cdc50fbcc1b","version":"d50d4e03ba724a1396bebb2a07b526de"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>This is a configurable component.&nbsp;It requires a configuration file in order to enable/disable Smart SAN functionality.&nbsp;If no configuration is performed, the current Smart SAN status is stated and the execution is complete.&nbsp;No further action is taken.</p>\n\n<p>&nbsp;</p>\n\n<p>For detailed information about configurable components, see the <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00106063en_us\"><em>Smart Update Manager User Guide </em></a></p>\n\n<p>&nbsp;</p>\n\n<p><strong>Component execution outside of HPE Service Pack for Proliant</strong>:</p>\n\n<ul>\n\t<li>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</li>\n\t<li>From that drive and directory, execute the downloaded file.</li>\n\t<li>Click the &quot;Install&quot; button to proceed with the installation.</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic Smart SAN Enablement Kit for Fibre Channel Host Bus Adapter for Microsoft Windows Server 2012R2/2016/2019 (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015D","subven":"1077","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015C","subven":"1077","target_guid":"","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-18T06:27:27","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to version 1.0.0.1</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"QLSMARTSANVer.exe","sw_key_expectedpath":"%SystemDrive%\\StorageWorks\\Version"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"HPE Smart Array controller driver component for VMware vSphere 6.7, for use with HPE Smart Update Manager."},{"lang":"ja","x_late":"HPE Smart Update Managerで使用するHPE Smartアレイコントローラードライバーコンポーネント for VMware vSphere 6.7。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"187510","datemodified":"2020-12-10T11:36:57","file_list":["/cp042875.xml","/HPE-nhpsa_67.0072.0.149-1OEM.670.0.0.8169922-offline_bundle-17300270.zip","/HPE-nhpsa_67.0072.0.149-1OEM.670.0.0.8169922-offline_bundle-17300270.zip/index.xml","/HPE-nhpsa_67.0072.0.149-1OEM.670.0.0.8169922-offline_bundle-17300270.zip/vendor-index.xml","/HPE-nhpsa_67.0072.0.149-1OEM.670.0.0.8169922-offline_bundle-17300270.zip/metadata.zip","/HPE-nhpsa_67.0072.0.149-1OEM.670.0.0.8169922-offline_bundle-17300270.zip/vib20/nhpsa/Microsemi_bootbank_nhpsa_67.0072.0.149-1OEM.670.0.0.8169922.vib","/HPE-nhpsa_67.0072.0.149-1OEM.670.0.0.8169922-offline_bundle-17300270.zip/metadata.zip/vendor-index.xml","/HPE-nhpsa_67.0072.0.149-1OEM.670.0.0.8169922-offline_bundle-17300270.zip/metadata.zip/vmware.xml","/HPE-nhpsa_67.0072.0.149-1OEM.670.0.0.8169922-offline_bundle-17300270.zip/metadata.zip/vibs/nhpsa--4151965318532592019.xml","/HPE-nhpsa_67.0072.0.149-1OEM.670.0.0.8169922-offline_bundle-17300270.zip/metadata.zip/bulletins/HPE-nhpsa_67.0072.0.149-1OEM.670.0.0.8169922.xml"],"md5sum":"7ac98ba1812a941f010df9bbec2a7424","name":"cp042875.zip","release":"2021-03-24T00:00:00","revision":"1","sha1sum":"ae6be703d84136b1f71dbc2cfce9d1f193dc9c47","size":"183KB","target_guids":[],"type_of_change":"1","version":"2021.01.01","vib_list":[{"name":"nhpsa","version":"67.0072.0.149-1OEM.670.0.0.8169922"}]}],"id":{"product":"bf1a27517d5b40049d86ae61d3476536","version":"5f0ed977c6754cc99e3518b7db1e038a"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant</strong></p>\n\n<p><strong>Remote Online: </strong></p>\n\n<ul>\n\t<li>&nbsp;Place the SPP on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\"><u>HPE USB Key Creator Utility</u></a><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">.</a></li>\n\t<li>&nbsp;Place the desired driver to be updated in the directory, /SPP20xxxxx/hp/swpackages on the USB key.</li>\n\t<li>&nbsp;Mount the USB key on a remote server running Windows or Linux</li>\n\t<li>&nbsp;CD /hp/swpackages and ./hpsum</li>\n\t<li>&nbsp;Select the next button</li>\n\t<li>&nbsp;Click Add Single Target</li>\n\t<li>&nbsp;Type the IP or DNS address of the ESXi host to be updated</li>\n\t<li>&nbsp;Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>&nbsp;Follow Smart Update Manager Steps and complete the update.</li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>&nbsp;Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>&nbsp;Use VMware VUM or esxcli commands to install the offline bundle.</li>\n\t<li>&nbsp;Refer to VMware documentation for information on VUM and the esxcli commands.</li>\n</ul>\n\n<p><br />\n&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、HPE Service Pack for ProLiantから以下の手順に従ってください</strong></p>\n\n<p><strong>リモートオンライン: </strong></p>\n\n<ul>\n\t<li> <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\"><u>HPE USB Key Creator Utility</u></a><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\">を使用して、SPPをUSBキーにコピーします。</a></li>\n\t<li> アップデートするドライバーをUSBキーの/SPP20xxxxx/hp/swpackagesディレクトリにコピーします。</li>\n\t<li> WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。</li>\n\t<li> CD /hp/swpackagesおよび./hpsum</li>\n\t<li> 次へボタンを選択します。</li>\n\t<li> シングルターゲットの追加をクリックします。</li>\n\t<li> 更新されるESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li> ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li> Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ul>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ul>\n\t<li> ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li>\n\t<li> オフラインバンドルをインストールするために、VMware VUMまたはesxcliコマンドを使用します。</li>\n\t<li> VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ul>\n\n<p><br/>\n </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE ProLiant Smart Array Controller Driver for VMware vSphere 6.7 (Driver Component)."},{"lang":"ja","x_late":"HPE ProLiant Smartアレイコントローラードライバーfor VMware vSphere 6.7 (ドライバーコンポーネント) "}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"3239","subdev":"21c2","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c0","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c3","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21be","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cb","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c1","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c5","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cc","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c7","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21bf","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c8","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c6","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ce","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ca","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21BD","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21CD","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-25T14:41:37","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>To add OS support for VMware ESXi 7.0 U1 P02</li>\n</ul>\n","latest_fixes_x_late":"<p>This release provides the following fixes:</p>\n\n<ul>\n\t<li>Fix failed TUR cmds hung in queue</li>\n\t<li>Fix internal cmd reservation broken</li>\n\t<li>Update for new version number scheme</li>\n\t<li>Fix verbose error messages on common innocuous errors<br />\n\t&nbsp;</li>\n\t<li>Failed logical volumes not being properly handled via offline state.</li>\n\t<li>Scsi sense and status returns are incorrect for some error conditions.</li>\n\t<li>Incorrect &#39;unavailable&#39; status seen during hot-plug recovery.</li>\n\t<li>Displayed target ID is incorrect in some driver log messages.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This release provides the following fixes:</p>\n\n<ul>\n\t<li>Fix failed TUR cmds hung in queue</li>\n\t<li>Fix internal cmd reservation broken</li>\n\t<li>Update for new version number scheme</li>\n\t<li>Fix verbose error messages on common innocuous errors<br />\n\t&nbsp;</li>\n\t<li>Failed logical volumes not being properly handled via offline state.</li>\n\t<li>Scsi sense and status returns are incorrect for some error conditions.</li>\n\t<li>Incorrect &#39;unavailable&#39; status seen during hot-plug recovery.</li>\n\t<li>Displayed target ID is incorrect in some driver log messages.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"nhpsa:67.0072.0.149-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel and Blade Storage Mezzanine Fibre Channel over Ethernet Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"4302720","datemodified":"2021-08-27T06:12:50","file_list":["./etc/depmod.d/brcmfcoe.conf","./etc/dracut.conf.d/brcmfcoe.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/brcmfcoe","./lib/modules/4.18.0-240.el8.x86_64/extra/brcmfcoe/brcmfcoe.ko","./usr/share/smartupdate/kmod-brcmfcoe/component.xml"],"md5sum":"80f6af07823fe1669ce614f1483cbcf4","name":"kmod-brcmfcoe-12.0.1342.0-1.rhel8u3.x86_64.rpm","release":"2021-08-27T06:02:07","revision":"0","sha1sum":"7a89392a901790691ab5115b486cb2782635fd1e","size":"4MB","target_guids":[],"type_of_change":"1","version":"12.0.1342.0"}],"id":{"product":"6a9398a45cee4bbabc175a6b2226c648","version":"074c618f183643ed8280e4c3396e5455"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh brcmfcoe-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh brcmfcoe-kmp-default-11.2.xxxx.x_3.0.76._0.11-1.sles11sp3.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e brcmfcoe-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Red Hat Enterprise Linux 8 Update 3 Server Fibre Channel over Ethernet (FCoE) Driver Kit for HPE Storage Emulex(BRCM) Converged Network Adapters and mezzanine Converged Network Adapters(CNAs)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T11:00:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to Driver version 12.0.1342.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"}],"sw_keys":[{"name":"kmod-brcmfcoe","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"9300211","languages":[{"lang":"fr","x_late":"Utilitaire - Outils"},{"lang":"en","x_late":"Utility - Tools"},{"lang":"cn","x_late":"实用程序 - 工具"},{"lang":"tw","x_late":"公用程式 ─ 工具"},{"lang":"de","x_late":"Hilfsprogramm - Tools"},{"lang":"ko","x_late":"유틸리티 – 도구"},{"lang":"it","x_late":"Utility - Strumenti"},{"lang":"ja","x_late":"ユーティリティ - ツール"},{"lang":"es","x_late":"Utilidad - Herramientas"}]}],"description":[{"lang":"en","x_late":"This package contains the HPE NVMe Name Server host agent kit supporting RoCEv2 capable HPE 25Gb Ethernet adapters  & HPE 100Gb Ethernet adapters for Linux operating systems."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"85428","datemodified":"2021-08-24T08:27:30","file_list":["./etc/nfc_nvme/hpe_nfc_nnscid.conf","./usr/lib/systemd/system/nns_service.service","./usr/sbin/nfc_config","./usr/sbin/nfc_param_set","./usr/sbin/nnsciadm","./usr/sbin/nnscid","./usr/share/smartupdate/HPE-NFC-host-agent-RHEL/component.xml"],"md5sum":"f84d289bcb14248028220feaf4ab0cdf","name":"HPE-NFC-host-agent-RHEL-1.0-1.rhel7u9.x86_64.rpm","release":"2021-08-24T08:20:10","revision":"0","sha1sum":"36418745177c9ece24805fc69f3cfc42960c0178","size":"83KB","target_guids":[],"type_of_change":"1","version":"1.0-1"},{"bytes":"85428","datemodified":"2021-08-24T08:28:42","file_list":["./etc/nfc_nvme/hpe_nfc_nnscid.conf","./usr/lib/systemd/system/nns_service.service","./usr/sbin/nfc_config","./usr/sbin/nfc_param_set","./usr/sbin/nnsciadm","./usr/sbin/nnscid","./usr/share/smartupdate/HPE-NFC-host-agent-RHEL/component.xml"],"md5sum":"d172c59f00ce5ac6b9f1e7c278c892cb","name":"HPE-NFC-host-agent-RHEL-1.0-1.rhel8u3.x86_64.rpm","release":"2021-08-24T08:20:10","revision":"0","sha1sum":"d1e737628199b89fc82f2ca4af5241dd311f44bc","size":"83KB","target_guids":[],"type_of_change":"1","version":"1.0-1"},{"bytes":"85427","datemodified":"2021-08-24T08:33:01","file_list":["./etc/nfc_nvme/hpe_nfc_nnscid.conf","./usr/lib/systemd/system/nns_service.service","./usr/sbin/nfc_config","./usr/sbin/nfc_param_set","./usr/sbin/nnsciadm","./usr/sbin/nnscid","./usr/share/smartupdate/HPE-NFC-host-agent-RHEL/component.xml"],"md5sum":"8312d0352d7d0e235231d53ef32730e0","name":"HPE-NFC-host-agent-RHEL-1.0-1.rhel7u8.x86_64.rpm","release":"2021-08-24T08:20:10","revision":"0","sha1sum":"19b0d9247b6c9a9290cac02fa20605e63da2e96d","size":"83KB","target_guids":[],"type_of_change":"1","version":"1.0-1"}],"id":{"product":"d3a5739ca7714fa8a9d8f102ed55e09f","version":"3c7dce096ba54e588ded891a8cbebde1"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE NFS host agent for RedHat Enterprise Linux(RHEL) Server -7/8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"","type":"pci","ven":"15b3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T10:36:01","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to version 1.0-1</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"}],"sw_keys":[{"name":"HPE-NFC-host-agent-RHEL","sw_key_expectedpath":"software:rpm"},{"name":"HPE-NFC-host-agent-RHEL","sw_key_expectedpath":"software:rpm"},{"name":"HPE-NFC-host-agent-RHEL","sw_key_expectedpath":"software:rpm"},{"name":"HPE-NFC-host-agent-RHEL","sw_key_expectedpath":"software:rpm"},{"name":"HPE-NFC-host-agent-RHEL","sw_key_expectedpath":"software:rpm"},{"name":"HPE-NFC-host-agent-RHEL","sw_key_expectedpath":"software:rpm"},{"name":"HPE-NFC-host-agent-RHEL","sw_key_expectedpath":"software:rpm"},{"name":"HPE-NFC-host-agent-RHEL","sw_key_expectedpath":"software:rpm"},{"name":"HPE-NFC-host-agent-RHEL","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel and Blade Storage Mezzanine Fibre Channel over Ethernet Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"426107","datemodified":"2021-08-27T06:09:53","file_list":["./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/brcmfcoe.ko","./usr/share/smartupdate/brcmfcoe-kmp-default/component.xml"],"md5sum":"cca2be4df2e1d2bc54d692fcebc54509","name":"brcmfcoe-kmp-default-12.0.1342.0_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-08-27T06:03:07","revision":"0","sha1sum":"8d9ab84c49243a915ed533b1c918f047a1043412","size":"416KB","target_guids":[],"type_of_change":"1","version":"12.0.1342.0"}],"id":{"product":"86bf272d1c074b4894d4b44c663781b2","version":"9ffcb2e71ce04d9693fe050908ac1061"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh brcmfcoe-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh brcmfcoe-kmp-default-11.2.xxxx.x_3.0.76._0.11-1.sles11sp3.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e brcmfcoe-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"SUSE Linux Enterprise Server 12 service pack 5 Fibre Channel over Ethernet (FCoE) Driver Kit for HPE Storage Emulex(BRCM) Converged Network Adapters and mezzanine Converged Network Adapters(CNAs)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T11:00:46","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to Driver version 12.0.1342.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"}],"sw_keys":[{"name":"brcmfcoe-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5950920","datemodified":"2021-05-18T04:11:16","file_list":["SignedImageInstaller64.dll","U15_2.90_04_29_2021.signed.flash","cp047854.xml","cpqsetup.exe","cpqsysio64.sys"],"md5sum":"dc9bc93df4d89d83e1a3ac8d15aed7cf","name":"cp047854.exe","release":"2021-05-18T03:54:07","revision":"0","sha1sum":"11c2c10a1b072d7bd6d86d4e53a6ba17bfca6afe","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021"}],"id":{"product":"56e73eced8704b9c871e50e0afbcdc84","version":"abca99ccedfd40cd9b1347598839cf6a"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL60 Gen9/DL80 Gen9 (U15) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant DL60 Gen9/DL80 Gen9（U15）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-05T03:53:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"}],"sw_keys":[{"name":"U15","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000JEQUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHC8SDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a45515556","Version":"HPDB"},{"DeviceName":"MB8000JEQVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHC8SDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3842-3030-304a45515641","Version":"HPDB"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB6000JEQUV and MB8000JEQVA"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MB6000JEQUVおよびMB8000JEQVA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB6000JEQUV and MB8000JEQVA Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDB<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD9<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"5513731","datemodified":"2021-07-23T07:36:18","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-df22f7effd-HPDB-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-df22f7effd-HPDB-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-df22f7effd-HPDB-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-df22f7effd-HPDB-8.1/CP048171.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-df22f7effd-HPDB-8.1/HAHC8SDB.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-df22f7effd-HPDB-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-df22f7effd-HPDB-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-df22f7effd-HPDB-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-df22f7effd-HPDB-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048171.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048171.scexe"],"md5sum":"9d56c63e1b8a23daa308919ed70b42ad","name":"firmware-hdd-df22f7effd-HPDB-8.1.x86_64.rpm","release":"2021-07-23T07:23:07","revision":"0","sha1sum":"23a2c15c0e430e9dcd6f87edc751ff5cf60fb9ec","size":"5MB","target_guids":["002340a5-4d00-3642-3030-304a45515556","002340a5-4d00-3842-3030-304a45515641"],"type_of_change":"1","version":"HPDB"}],"id":{"product":"9c74011372f646da931c0840d918013f","version":"e6fa796f74a54adf823551bebe089727"},"installation":{"command":"CP040350.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">Follow the instructions on the screen.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">画面の指示に従います。</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB6000JEQUV and MB8000JEQVA Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB6000JEQUVおよびMB8000JEQVAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB6000JEQUV","target_guid":"002340a5-4d00-3642-3030-304a45515556","type":"sas"},{"id":"MB8000JEQVA","target_guid":"002340a5-4d00-3842-3030-304a45515641","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T19:54:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB8000JEQVA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB6000JEQUV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK0960GECQK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSV843G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304b-3936-30474543514b","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SATA drive models: MK0960GECQK"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。 MK0960GECQK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MK0960GECQK Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:<br />\n&nbsp; &nbsp; &nbsp;</strong>None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features&nbsp;:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Firmware fixes intermittent data corruption issue associated with unaligned sequential write operations.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4614956","datemodified":"2021-07-23T07:47:09","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-3e34285be7-HPG3-11.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-3e34285be7-HPG3-11.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-3e34285be7-HPG3-11.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3e34285be7-HPG3-11.1/CP048178.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-3e34285be7-HPG3-11.1/GSV843G3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-3e34285be7-HPG3-11.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3e34285be7-HPG3-11.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-3e34285be7-HPG3-11.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-3e34285be7-HPG3-11.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048178.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048178.scexe"],"md5sum":"d91e7b1fdcb8638fdb1af454e1e9fc1f","name":"firmware-hdd-3e34285be7-HPG3-11.1.x86_64.rpm","release":"2021-07-23T07:34:17","revision":"0","sha1sum":"7b7a8ea4146adb9cabfeadf22112cf6da41657e1","size":"4MB","target_guids":["002340a5-4d00-304b-3936-30474543514b"],"type_of_change":"2","version":"HPG3"}],"id":{"product":"63eaf8b9f2d74ded922cd74f7d530631","version":"c510c34f0a584917a49984e64618cb14"},"installation":{"command":"CP040262.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MK0960GECQK Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MK0960GECQKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"MK0960GECQK","target_guid":"002340a5-4d00-304b-3936-30474543514b","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T20:20:55","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Firmware fixes intermittent data corruption issue associated with unaligned sequential write operations.</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Firmware fixes intermittent data corruption issue associated with unaligned sequential write operations.</li>\n</ul>","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK0960GECQK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component contains version 9.4.5.20 of the QLogic Storport driver which provides Mezzanine Fibre Channel Host Bus Adapter driver support for HPE storage arrays."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"1614136","datemodified":"2021-08-27T04:47:58","file_list":["cp048716.xml","cpqsetup.exe","install.xml","ql2300.cat","ql2300.sys","ql2x00.inf","QLOGIC","qlsrvc.exe","QlStorInstaller.dll","readme.txt","release.txt","SysConfig.frm","SysConfig.frm.ja","txtsetup.oem"],"md5sum":"b48bfbee9cfc325412fa857e4fe07bdd","name":"cp048716.exe","release":"2021-08-27T04:45:05","revision":"0","sha1sum":"39c16a6522b144d823c3a578981ba203fdd19e9f","size":"1MB","target_guids":[],"type_of_change":"1","version":"9.4.5.20"}],"id":{"product":"a7c03a410bff4bf592afce6553f421c4","version":"42ef17bdcfb04b45bc22cdc80feae8bd"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br />\n<br />\nFrom that drive and directory, execute the downloaded file.<br />\n<br />\nClick the &quot;Install&quot; button to proceed with the installation.<br />\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Mezzanine Fibre Channel Adapter Kit for the x64 QLogic Storport Driver for Microsoft Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-18T06:27:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Made improvements to the Fabric Port Identification Number (FPIN) and Universal Storage Area Network (SAN) Congestion Mitigation (USCM) Congestion Management algorithms.</li>\n</ul>\n\n<p>Updated&nbsp;to&nbsp;version&nbsp;9.4.5.20</p>\n","curr_fixes_x_late":"<ul>\n\t<li>Removed the &quot;fwload&quot; registry parameter.</li>\n\t<li>Fixed an unwanted behavior where Link up/down messages were not always logged in the Window System Event log.</li>\n\t<li>Fixed unwanted behavior with the reporting of Fabric Port Identification Number (FPIN) and Universal Storage Area Network (SAN) Congestion Mitigation (USCM) statistics.</li>\n\t<li>Fixed an unwanted behavior where connections to tape drives may fail to recover in the event of &quot;SCSI Check Condition&quot; commands or cable pulls.</li>\n\t<li>Fixed an unwanted behavior where the server may encounter a Blue Screen Of Death (BSOD) 0x0000009f message during shutdown as described in <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00116202en_us\">Advisory: HPE Host Bus Adapters - HPE Platforms Running a Microsoft Windows Server 2016 / 2019 Hyper-V Environment, and Configured With Certain HPE HBAs With the QLogic Storport Driver v9.4.2.20, May Experience a Bug Check 0x9F Event</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"ql2300.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5906504","datemodified":"2021-05-18T05:09:35","file_list":["P99_2.90_04_29_2021.signed.flash","SignedImageInstaller64.dll","cp047845.xml","cpqsetup.exe","cpqsysio64.sys"],"md5sum":"7710f26c99eb285007011e472160abaf","name":"cp047845.exe","release":"2021-05-18T04:52:10","revision":"0","sha1sum":"44046c0feb8ec6d81ac18fd435981a288c08a33d","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021"}],"id":{"product":"37828e7bce5241f6a19b4fa05756658e","version":"ffa4663807af4ad0ba54d80d625c7d87"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.<br />\n&nbsp;</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br />\n </p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML110 Gen9 (P99) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant ML110 Gen9 (P99)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"edition":"fndtn","major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2 Foundation Edition","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-05T03:46:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"}],"sw_keys":[{"name":"P99","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900213","languages":[{"lang":"fr","x_late":"Micrologiciel - Lights-Out Management"},{"lang":"en","x_late":"Firmware - Lights-Out Management"},{"lang":"cn","x_late":"固件 - Lights-Out Management"},{"lang":"tw","x_late":"韌體 ─ Lights─Out 管理"},{"lang":"de","x_late":"Firmware - LOM (Lights-Out Management)"},{"lang":"ko","x_late":"펌웨어 - Lights-Out 관리"},{"lang":"ja","x_late":"ファームウェア - Lights-Outマネジメント"},{"lang":"es","x_late":"Firmware - Administración de apagado eléctrico"}]}],"description":[{"lang":"en","x_late":"This component provides and installs an updated version of firmware for the iLO 4 Management Processor on Windows 64 bit Operating System. Use this component with HPE Smart Update Manager to update supported HPE ProLiant Gen8 and Gen9, HPE Apollo Gen9, and HPE Synergy 480 Gen9 systems. Click the “Installation Instructions” tab to review important firmware update details."},{"lang":"ja","x_late":"このコンポーネントは、Windows 64ビットオペレーティングシステムでiLO 4マネジメントプロセッサーのアップデートされたバージョンのファームウェアを提供しインストールします。このコンポーネントをHPE Smart Update Managerとともに使用して、サポートされているHPE ProLiant Gen8およびGen9、HPE Apollo Gen9、およびHPE Synergy 480 Gen9システムをアップデートします。[インストール手順]タブをクリックして、重要なファームウェアアップデートの詳細を確認します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[{"lang":"en","x_late":"<p>&nbsp;</p>\n\n<p>iLO&nbsp;4 User Guide and Lights-Out Scripting Guide can also be found by following the links at:<br />\n<br />\n<a href=\"http://www.hpe.com/info/ilo\">http://www.hpe.com/info/ilo</a><br />\n<br />\nSelect your lights-out product, then support &amp; documents, then manuals.<br />\n&nbsp;</p>\n\n<ul>\n\t<li>Check the online help for additional information about how to use features.&nbsp;<br />\n\tOnline help can be accessed from within the browser web pages by clicking the question mark in the upper right-hand corner of each page.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p> </p>\n\n<p>iLO 4ユーザーガイドおよびLights-Outスクリプティングガイドは、以下のリンクから入手可能です。<br/>\n<br />\n<a href=\"http://www.hpe.com/info/ilo\">http://www.hpe.com/info/ilo</a><br/>\n<br />\nご使用のLights-Out製品、サポートドキュメント、ドキュメントの順に選択します。<br />\n </p>\n\n<ul>\n\t<li>この機能の使用方法について詳しくは、オンラインヘルプを参照してください。 <br />\n\tオンラインヘルプは、各ページの右上隅のクエスチョンマークをクリックすると、ブラウザーからアクセスできます。</li>\n</ul>\n"}],"files":[{"bytes":"14021336","datemodified":"2021-04-28T16:30:44","file_list":["SignedImageInstaller64.dll","cp046467.xml","cpqsetup.exe","cpqsysio64.sys","ilo4_278.bin","readme.txt"],"md5sum":"674446cde2ed7d3dedf0b9db7289caad","name":"cp046467.exe","release":"2021-05-07T00:00:00","revision":"1","sha1sum":"a78da381d34e5e3f6631ded4ac4f1453a549adc3","size":"13MB","target_guids":[],"type_of_change":"2","version":"2.78"}],"id":{"product":"2137f29484a3411eb23b24a938438e8b","version":"0a4340bdaeac4ca680ab71f54884e5ac"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 3/4 Channel Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 3/4 Channel Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"}]},{"ListConditional":"OR","Requirement":[]}]}]},"installation_notes":[{"lang":"en","x_late":"<h2><strong>For supported HPE Synergy 480 Gen9 Systems:</strong></h2>\n\n<p>This firmware release is fully supported when applied as a hotfix to the following HPE Synergy Software Releases:&nbsp;</p>\n\n<ul>\n\t<li>All HPE OneView versions 5.4&nbsp;and later in combination with HPE Synergy Custom SPP 2020.07, and HPE Synergy Custom SPP 2021.01</li>\n\t<li>All HPE OneView versions 5.6 and later in combination with HPE Synergy Custom SPP 2021.02</li>\n</ul>\n\n<p>For Synergy Hotfix installation instructions see HPE iLO User guide [https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=c03334051] sections titled:&nbsp;</p>\n\n<ul>\n\t<li>Adding hotfixes to create an HPE OneView custom firmware bundle</li>\n\t<li>Using HPE Smart Update Manager to create a custom ISO on Windows</li>\n</ul>\n\n<h2><strong>For supported HPE ProLiant Gen8, ProLiant Gen9, Apollo 4200 Gen9, and Apollo 4350 Gen9 Systems: </strong></h2>\n\n<p><strong>Install the firmware using one of these options:</strong></p>\n\n<ul>\n\t<li>Run the Component on the host to be updated.<br />\n\tThe component will update the iLO&nbsp;4 firmware and reset the iLO&nbsp;4 processor.<br />\n\t&nbsp;</li>\n\t<li>Extract the firmware from the component.&nbsp; This will place the firmware image file, iLO4_yyy.bin (where yyy represents the firmware version) in the target directory.&nbsp; You now have these options:\n\t<ul>\n\t\t<li>Login to iLO 4, navigate to the Update Firmware page, and update the firmware from there.</li>\n\t\t<li>Use the HPE Lights-Out Configuration Utility, CPQLOCFG, and RIBCL/XML scripts to update iLO&nbsp;4 across the network.</li>\n\t\t<li>Use the HPE Online Lights-Out Configuration utility, HPONCFG, and RIBCL/XML scripts to update iLO&nbsp;4 from the supported host OS.</li>\n\t\t<li>Use the Directory Migration Utility, contained in the <a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_573a541eab8c439db63dc4d3be#\">HPE Directories support for Management Processors</a>, &nbsp;The Windows utility supports&nbsp;network discovery of lights-out processors, import/export, as well as bulk firmware update, and does not require directory migration.</li>\n\t</ul>\n\t</li>\n</ul>\n"},{"lang":"ja","x_late":"<h2><strong>サポートされているHPE Synergy 480 Gen9システムの場合：</strong></h2>\n\n<p>このファームウェアリリースは、次のHPE Synergyソフトウェアリリースのホットフィックスとして適用されると完全にサポートされます。 </p>\n\n<ul>\n\t<li>HPE OneViewバージョン5.4以降のすべてと、HPE SynergyカスタムSPP 2020.07およびHPE SynergyカスタムSPP 2021.01の組み合わせ</li>\n\t<li>HPE OneViewバージョン5.6以降のすべてと、HPE SynergyカスタムSPP 2021.02の組み合わせ</li>\n</ul>\n\n<p>Synergyホットフィックスのインストール手順については、HPE iLOユーザーガイド[https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&docId=c03334051]で次のタイトルのセクションを参照してください。 </p>\n\n<ul>\n\t<li>Adding hotfixes to create an HPE OneView custom firmware bundle</li>\n\t<li>Using HPE Smart Update Manager to create a custom ISO on Windows</li>\n</ul>\n\n<h2><strong>サポートされているHPE ProLiant Gen8、ProLiant Gen9、Apollo 4200 Gen9、およびApollo 4350 Gen9システムの場合：</strong></h2>\n\n<p><strong>以下のいずれかのオプションを使用してファームウェアをインストールしてください。</strong></p>\n\n<ul>\n\t<li>アップデートするホスト上のコンポーネントを実行します。<br />\n\tこのコンポーネントは、iLO 4ファームウェアをアップデートし、iLO 4プロセッサーをリセットします。<br />\n\t </li>\n\t<li>コンポーネントからファームウェアを抽出します。  これにより、iLO4_yyy.bin (yyyはファームウェアバージョン)がターゲットディレクトリにコピーされます。  以下のオプションがあります。\n\t<ul>\n\t\t<li>iLO 4にログインし、アップデートファームウェアページに移動して、ファームウェアをアップデートします。</li>\n\t\t<li>ネットワーク経由でiLO 4をアップデートするには、HPE Lights-Out構成ユーティリティ、CPQLOCFG、およびRIBCL/XMLスクリプトを使用します。</li>\n\t\t<li>サポートされるホストOSからiLO 4をアップデートするには、HPEオンラインLights-Out構成ユーティリティ、HPONCFG、およびRIBCL/XMLスクリプトを使用します。</li>\n\t\t<li><a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_573a541eab8c439db63dc4d3be#\">HPE Directories support for Management Processors</a>に含まれているDirectory Migrationユーティリティを使用します。このWindowsユーティリティでは、Lights-Outプロセッサーのネットワーク検出、インポート/エクスポート機能、およびバルクファームウェアアップデートをサポートしており、ディレクトリの移行は不要です。</li>\n\t</ul>\n\t</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE Integrated Lights-Out 4"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows x64- HPE Integrated Lights-Out 4"}],"prerequisites":{"required_diskspace":{"size_kb":"5120"},"supported_devices":[{"id":"5219994","target_guid":"","type":"other"},{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3308","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3300","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3301","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3302","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"6","minor":"1","name":"Microsoft Windows 7 (64-bit) - All Editions","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows 8.1 (64-bit)","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"0","name":"Microsoft Windows Server 2008 x64","platform":"nt_x86-64","sr":"OEM"},{"edition":"srvr","major":"6","minor":"0","name":"Microsoft Windows Server 2008 x64 - Server Edition","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"0","name":"Microsoft Windows Vista (64-bit)","platform":"nt_x86-64","sr":"OEM"},{"edition":"bus","major":"6","minor":"0","name":"Microsoft Windows Vista Business (64-bit)","platform":"nt_x86-64","sr":"OEM"},{"edition":"ent","major":"6","minor":"0","name":"Microsoft Windows Vista Enterprise (64-bit)","platform":"nt_x86-64","sr":"OEM"},{"major":"5","minor":"1","name":"Microsoft Windows XP 64-Bit Edition","platform":"NT64","sr":"OEM"},{"major":"5","minor":"2","name":"Microsoft Windows XP Professional x64 Edition","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T12:36:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>&nbsp;-&nbsp; Updated Jquery library to 3.5.1<br />\n&nbsp;-&nbsp; Updated Openssl library to OpenSSL 1.0.2x<br />\n&nbsp;-&nbsp; eRS enhanced to support generic service event 1000 for critical events<br />\n&nbsp;</p>\n","latest_fixes_x_late":"<p>- IML reports fan modules failed for D3000 only after server reboot<br />\n&nbsp;&nbsp; &nbsp;- eRS service event added for Critical events like System Power Fault Detection<br />\n&nbsp;&nbsp; &nbsp;- Security fixes<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; - Added a Content Security Policy( CSP) to harden the web interfaces<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; - Enhanced Input validation for user controlled data</p>\n\n<p>- Fixes for multiple security vulnerabilities</p>\n"},{"curr_enhancements_x_late":"<p>&nbsp;-&nbsp; Updated Jquery library to 3.5.1<br />\n&nbsp;-&nbsp; Updated Openssl library to OpenSSL 1.0.2x<br />\n&nbsp;-&nbsp; eRS enhanced to support generic service event 1000 for critical events<br />\n&nbsp;</p>\n","curr_fixes_x_late":"<p>- IML reports fan modules failed for D3000 only after server reboot<br />\n&nbsp;&nbsp; &nbsp;- eRS service event added for Critical events like System Power Fault Detection<br />\n&nbsp;&nbsp; &nbsp;- Security fixes<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; - Added a Content Security Policy( CSP) to harden the web interfaces<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; - Enhanced Input validation for user controlled data</p>\n\n<p>- Fixes for multiple security vulnerabilities</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"P94","value":"HP ProLiant XL220a Gen8 v2 Server"},{"key":"J06","value":"HP ProLiant MicroServer Gen8"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P74","value":"HP ProLiant SL140s Gen8 Server (private)"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P98","value":"HP ProLiant SL220f Gen8 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"Carbondale14","value":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A29","value":"HP ProLiant DL585 Gen8 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 SE Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P78","value":"HP ProLiant ML310e Gen8 v2 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"P83","value":"HP ProLiant SL210t Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P94","value":"HP ProLiant SL241n Gen8 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"P91","value":"HP ProLiant SL240n Gen8 Server - cancelled"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P93","value":"HP ProLiant SL240d Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 SE Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"}],"sw_keys":[{"name":"RI10","sw_key_expectedpath":"firmware:ilo4"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWBXQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAGLXYG8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304757425851","Version":"HPG8"},{"DeviceName":"MB008000GWBYL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAGLXYG8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-30475742594c","Version":"HPG8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB006000GWBXQ and MB008000GWBYL "},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： MB006000GWBXQおよびMB008000GWBYL "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB006000GWBXQ and MB008000GWBYL Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG6<br />\n<br />\n<strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4445504","datemodified":"2021-07-23T18:36:31","file_list":["cp048667.xml","cpqsetup.exe","payload.json","setup.dll","TAGLXYG8.REL"],"md5sum":"d113891eda189280adaaa1a295764e86","name":"cp048667.exe","release":"2021-07-23T18:28:05","revision":"0","sha1sum":"761183bb7b7b31c0457e7fefa1948c7f12eaa743","size":"4MB","target_guids":["4d2340a5-3042-3630-3030-304757425851","4d2340a5-3042-3830-3030-30475742594c"],"type_of_change":"1","version":"HPG8"}],"id":{"product":"15b8ab8f16cc44ddb79fc673833826dc","version":"9074efde514b44d3818b41d5f56d3190"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB006000GWBXQ and MB008000GWBYL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows(x64) - MB006000GWBXQおよびMB008000GWBYLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB006000GWBXQ","target_guid":"4d2340a5-3042-3630-3030-304757425851","type":"sata"},{"id":"MB008000GWBYL","target_guid":"4d2340a5-3042-3830-3030-30475742594c","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-17T07:34:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000GWBXQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB008000GWBYL","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400JWDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57444b50","Version":"HPD2"},{"DeviceName":"EO000800JWDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57444b51","Version":"HPD2"},{"DeviceName":"EO001600JWDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57444b52","Version":"HPD2"},{"DeviceName":"MO000400JWDKU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57444b55","Version":"HPD2"},{"DeviceName":"MO000800JWDKV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57444b56","Version":"HPD2"},{"DeviceName":"MO001600JWDLA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57444c41","Version":"HPD2"},{"DeviceName":"MO003200JWDLB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57444c42","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EO000400JWDKP、EO000800JWDKQ、EO001600JWDKR、MO000400JWDKU、MO000800JWDKV、 MO001600JWDLA および MO003200JWDLB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD1<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"17655034","datemodified":"2021-08-30T07:39:40","file_list":["/CP048297_BUILD_2.data","/CP048297.vmexe","/CP048297.vmexe64","/CP048297.vmfile","/CP048297_VMw.zip","/CP048297.xml","/payload.json","/CP048297_VMw.zip/index.xml","/CP048297_VMw.zip/vendor-index.xml","/CP048297_VMw.zip/metadata.zip","/CP048297_VMw.zip/vib20/CP048297/HPE_bootbank_CP048297_HPD2.2-7.0.0.15843807.vib","/CP048297_VMw.zip/metadata.zip/vendor-index.xml","/CP048297_VMw.zip/metadata.zip/vmware.xml","/CP048297_VMw.zip/metadata.zip/vibs/CP048297--7520315920368581652.xml","/CP048297_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048297_HPD2.2-7.0.0.15843807.xml"],"md5sum":"747751d19d546bb3242fc23de8484b30","name":"CP048297.zip","release":"2021-08-30T07:34:50","revision":"0","sha1sum":"58e95422d68e8cfc53483c47ea41fd0492cf5bb3","size":"16MB","target_guids":["452340a5-304f-3030-3430-304a57444b50","452340a5-304f-3030-3830-304a57444b51","452340a5-304f-3130-3630-304a57444b52","4d2340a5-304f-3030-3430-304a57444b55","4d2340a5-304f-3030-3830-304a57444b56","4d2340a5-304f-3130-3630-304a57444c41","4d2340a5-304f-3330-3230-304a57444c42"],"type_of_change":"1","version":"HPD2","vib_list":[{"name":"CP048297","version":"HPD2.2-7.0.0.15843807"}]}],"id":{"product":"d54c971d2c3047569ed2e37939cd2848","version":"33fe48591db5429eaf0c825e5302057d"},"installation":{"command":"CP040645.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - EO000400JWDKP、EO000800JWDKQ、EO001600JWDKR、MO000400JWDKU、MO000800JWDKV、MO001600JWDLA および MO003200JWDLBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MO003200JWDLB","target_guid":"4d2340a5-304f-3330-3230-304a57444c42","type":"sas"},{"id":"MO001600JWDLA","target_guid":"4d2340a5-304f-3130-3630-304a57444c41","type":"sas"},{"id":"EO001600JWDKR","target_guid":"452340a5-304f-3130-3630-304a57444b52","type":"sas"},{"id":"MO000800JWDKV","target_guid":"4d2340a5-304f-3030-3830-304a57444b56","type":"sas"},{"id":"EO000800JWDKQ","target_guid":"452340a5-304f-3030-3830-304a57444b51","type":"sas"},{"id":"MO000400JWDKU","target_guid":"4d2340a5-304f-3030-3430-304a57444b55","type":"sas"},{"id":"EO000400JWDKP","target_guid":"452340a5-304f-3030-3430-304a57444b50","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-03T09:34:23","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EO000400JWDKP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600JWDLA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000800JWDKQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000400JWDKU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200JWDLB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800JWDKV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO001600JWDKR","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"9300211","languages":[{"lang":"fr","x_late":"Utilitaire - Outils"},{"lang":"en","x_late":"Utility - Tools"},{"lang":"cn","x_late":"实用程序 - 工具"},{"lang":"tw","x_late":"公用程式 ─ 工具"},{"lang":"de","x_late":"Hilfsprogramm - Tools"},{"lang":"ko","x_late":"유틸리티 – 도구"},{"lang":"it","x_late":"Utility - Strumenti"},{"lang":"ja","x_late":"ユーティリティ - ツール"},{"lang":"es","x_late":"Utilidad - Herramientas"}]}],"description":[{"lang":"en","x_late":"This This package contains the HPE NVMe Name Server host agent kit supporting RoCEv2 capable HPE 25Gb Ethernet adapters  & HPE 100Gb Ethernet adapters for Linux operating systems."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"84521","datemodified":"2021-08-24T08:32:02","file_list":["./etc/nfc_nvme/hpe_nfc_nnscid.conf","./usr/lib/systemd/system/nns_service.service","./usr/sbin/nfc_config","./usr/sbin/nfc_param_set","./usr/sbin/nnsciadm","./usr/sbin/nnscid","./usr/share/smartupdate/HPE-NFC-host-agent-SLES/component.xml"],"md5sum":"0aaec8220f605e765c9d61a53b0c3a1a","name":"HPE-NFC-host-agent-SLES-1.0-1.sles12sp5.x86_64.rpm","release":"2021-08-24T08:22:06","revision":"0","sha1sum":"2914fc6cfb871814ac8d2cb1c91e651f637a74e2","size":"82KB","target_guids":[],"type_of_change":"1","version":"1.0-1"},{"bytes":"84522","datemodified":"2021-08-24T08:29:19","file_list":["./etc/nfc_nvme/hpe_nfc_nnscid.conf","./usr/lib/systemd/system/nns_service.service","./usr/sbin/nfc_config","./usr/sbin/nfc_param_set","./usr/sbin/nnsciadm","./usr/sbin/nnscid","./usr/share/smartupdate/HPE-NFC-host-agent-SLES/component.xml"],"md5sum":"50c0abd97deb4f384888d3b2191e6749","name":"HPE-NFC-host-agent-SLES-1.0-1.sles15sp2.x86_64.rpm","release":"2021-08-24T08:22:06","revision":"0","sha1sum":"9a351f51149ad92caf4222d2f03981c9d41e0b23","size":"82KB","target_guids":[],"type_of_change":"1","version":"1.0-1"}],"id":{"product":"e7d5d76522b4487ea9c6c72e9b389320","version":"dd5b65a64d664501850c3d294416c50f"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE NFS host agent for SuSE Linux Enterprise Server 12 Service Pack5/15 Service Pack2"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"","type":"pci","ven":"15b3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T10:36:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial Version</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"}],"sw_keys":[{"name":"HPE-NFC-host-agent-SLES","sw_key_expectedpath":"software:rpm"},{"name":"HPE-NFC-host-agent-SLES","sw_key_expectedpath":"software:rpm"},{"name":"HPE-NFC-host-agent-SLES","sw_key_expectedpath":"software:rpm"},{"name":"HPE-NFC-host-agent-SLES","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"This component installs a Registry change to fix a fatal Non-Maskable Interrupt (NMI) when ejecting an NVMe drive."},{"lang":"ja","x_late":"このコンポーネントは、NVMeドライブを取り外す場合に致命的なNon-Maskable Interrupt (NMI)を修正するためにレジストリの変更をインストールします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]}],"documentation":[],"files":[{"bytes":"614744","datemodified":"2018-10-02T19:17:52","file_list":["cp035799.xml","cpqsetup.exe","genericmsi.dll","nvmeejectfix.msi","nvmefix.cab"],"md5sum":"29b7e47e0fe04728cd120232539cf37e","name":"cp035799.exe","release":"2018-10-03T00:17:03","revision":"0","sha1sum":"efea38ffd19ab187817dfb10c27ee8ed4ed95531","size":"600KB","target_guids":[],"type_of_change":"0","version":"1.0.5.0"}],"id":{"product":"a1a3e71f172a45da8be70ea29ecf3efc","version":"5cfa7432e0f941f8a62f5cb0e80fe790"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.\n<p>From that drive and directory, execute the downloaded file. \n<p>Click the \"Install\" button to proceed with the installation."},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。 ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。\n<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。 \n<p>[インストール]ボタンをクリックして、インストールを開始します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"NVMe Drive Eject NMI Fix for Intel Xeon v3 and Xeon v4 Processors for Windows Server 2012 R2 to Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_devices":[{"dev":"6F20","subdev":"21EA","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"6F20","subdev":"18A8","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"2F20","subdev":"0000","subven":"8086","target_guid":"","type":"pci","ven":"8086"},{"dev":"2F20","subdev":"21EA","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"2F20","subdev":"18A8","subven":"103C","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows 8.1 (64-bit)","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2018-11-13T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Changed component name to indicate which processors are supported. Systems that already have version 1.0.5.0 installed do not need to install this component.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Add support for Windows Server 2019.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"}],"sw_keys":[{"name":"nvmeejectfix.dll","sw_key_expectedpath":"%ProgramFiles%\\Hewlett Packard Enterprise\\nvmefix"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"nmlx5 is the low level driver implementation for the ConnectX®-4 and ConnectX®-5 adapters for VMware ESXi 6.7 Mellanox Ethernet Adapters."},{"lang":"ja","x_late":"nmlx5は、VMware ESXi 6.7 Mellanox Ethernetアダプター用ConnectX®-4およびConnectX®-5アダプターの低レベルドライバー実装です。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"703811","datemodified":"2021-08-27T13:38:16","file_list":["/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-17650904.zip","/cp047576.xml","/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-17650904.zip/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-offline_bundle-17650904.zip","/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-17650904.zip/doc/README.txt","/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-17650904.zip/doc/release_note_nmlx5-core_4.17.71.1-1OEM.670.0.0.8169922.pdf","/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-17650904.zip/doc/release_note_nmlx5-rdma_4.17.71.1-1OEM.670.0.0.8169922.pdf","/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-17650904.zip/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-offline_bundle-17650904.zip/index.xml","/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-17650904.zip/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-offline_bundle-17650904.zip/vendor-index.xml","/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-17650904.zip/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-offline_bundle-17650904.zip/metadata.zip","/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-17650904.zip/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-offline_bundle-17650904.zip/vib20/nmlx5-core/MEL_bootbank_nmlx5-core_4.17.71.1-1OEM.670.0.0.8169922.vib","/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-17650904.zip/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-offline_bundle-17650904.zip/vib20/nmlx5-rdma/MEL_bootbank_nmlx5-rdma_4.17.71.1-1OEM.670.0.0.8169922.vib","/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-17650904.zip/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-offline_bundle-17650904.zip/metadata.zip/vendor-index.xml","/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-17650904.zip/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-offline_bundle-17650904.zip/metadata.zip/vmware.xml","/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-17650904.zip/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-offline_bundle-17650904.zip/metadata.zip/vibs/nmlx5-core--2359207540222518703.xml","/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-17650904.zip/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-offline_bundle-17650904.zip/metadata.zip/vibs/nmlx5-rdma--5396774233207068486.xml","/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-17650904.zip/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-offline_bundle-17650904.zip/metadata.zip/bulletins/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922.xml"],"md5sum":"796641458d637511be48bf7a2d0c2cb9","name":"cp047576.zip","release":"2021-08-27T13:37:05","revision":"0","sha1sum":"8f181295393f282b73673e58accdd8f54638d46f","size":"687KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec41bd2821","20a6e8e4-bf33-4c71-a6bf-d9ecdebb2a48"],"type_of_change":"1","version":"2021.04.15","vib_list":[{"name":"nmlx5-core","version":"4.17.71.1-1OEM.670.0.0.8169922"},{"name":"nmlx5-rdma","version":"4.17.71.1-1OEM.670.0.0.8169922"}]}],"id":{"product":"8e7aaa71b17c4086a95b8b9f64ce4863","version":"cb72222cae8847cc8357c672ce5bf593"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Remote Online:&nbsp;</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the HPE USB Key Creator Utility.&nbsp;</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux .</li>\n\t<li>cd /SPP20xxxxx/ and launch SUM&nbsp;(launch_sum.bat for Windows and ./launch_sum.sh for Linux).</li>\n\t<li>Select &quot;Baseline Library&quot; and wait for the Baseline inventory to complete.</li>\n\t<li>Select &quot;Nodes&quot; from the &quot;Smart Update Manager x.x.x&quot; drop down.</li>\n\t<li>Click, &quot;Add Node&quot;.\n\t<ul>\n\t\t<li>If adding a Gen9 server,\n\t\t<ul>\n\t\t\t<li>Provide IP address of the ESXi host.</li>\n\t\t\t<li>Enter&nbsp;the ESXi host credentials (root or administrator username and password)&nbsp;</li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>If adding a Gen10 and above server,\n\t\t<ul>\n\t\t\t<li>Provide iLO IP address of the ESXi host server.</li>\n\t\t\t<li>Enter the iLO credentials of the ESXi host server.</li>\n\t\t</ul>\n\t\t</li>\n\t</ul>\n\t</li>\n\t<li>Follow&nbsp;Smart Update Manager Steps and complete the driver update.&nbsp;</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware VUM or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>リモートオンライン: </strong></p>\n\n<ol>\n\t<li>HPE USB Key Creator Utilityを使用して、SPPをUSBキーにコピーします。 </li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。</li>\n\t<li>cd /SPP20xxxxx およびSUMを起動します。（Windowsの場合はlaunch_sum.bat、Linuxの場合は./launch_sum.sh）</li>\n\t<li>\"ベースラインライブラリ\"を選択し、ベースラインインベントリが完了するのを待ちます。</li>\n\t<li>\"Smart Update Manager x.x.x\"ドロップダウンから\"ノード\"を選択します。</li>\n\t<li>\"ノードの追加\"をクリックします。\n\t<ul>\n\t\t<li>Gen9サーバーを追加する場合、\n\t\t<ul>\n\t\t\t<li>ESXiホストのIPアドレスを提供します。</li>\n\t\t\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します </li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>Gen10以降のサーバーを追加する場合、\n\t\t<ul>\n\t\t\t<li>ESXiホストサーバーのiLO IPアドレスを提供します。</li>\n\t\t\t<li>ESXiホストサーバーのiLO認証情報を入力します。</li>\n\t\t</ul>\n\t\t</li>\n\t</ul>\n\t</li>\n\t<li>Smart Update Managerの指示に従い、ドライバーのアップデートを完了します。 </li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li>\n\t<li>オフラインバンドルをインストールするために、VMware VUMまたはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"nmlx5_en Driver Component for VMware 6.7"},{"lang":"ja","x_late":"nmlx5_enドライバーコンポーネント for VMware 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"032D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-10171590032d","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30047","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"0221","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101315900221","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-16T12:04:36","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Changes and New Features in smart component version 2020.11.11:</strong></p>\n\n<ul>\n\t<li>Added support for the following adapters:\n\t<ul>\n\t\t<li>HPE Ethernet 200Gb 1-Port QSFP56 MCX623105AS-VDAT Adapter (HPE Part Number: P10180-B21)</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>New features and changes in version 4.17.70.1:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Disabled the option of shutting down the link due to power limitation.</p>\n\t</li>\n\t<li>\n\t<p>Support for trusting Differentiated Services Code Point (DSCP) and setting default value for RoCE traffic.</p>\n\t</li>\n\t<li>\n\t<p>New counter that enables the user to query per Virtual Function counters.</p>\n\t</li>\n\t<li>\n\t<p>RX out-of-buffer counter to indicate any lack of software receive buffers.</p>\n\t</li>\n\t<li>\n\t<p>Module parameter to enforce specific RoCE version.</p>\n\t</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version&nbsp;in 4.17.70.1:</strong></p>\n\n<ul>\n\t<li>\n\t<p>The &quot;esxcli network sriovnic vf stats&quot; command&nbsp;was not supported.When running this command on a &quot;vmknic&quot;, a failure message&nbsp;was displayed.</p>\n\t</li>\n\t<li>\n\t<p>IPv6 as inner packet was not supported.</p>\n\t</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Changes and New Features in smart component version 2021.04.15:</strong></p>\n\n<ul>\n\t<li>Added support for the following adapters:\n\t<ul>\n\t\t<li>HPE Ethernet 200Gb 1-Port QSFP56 MCX623105AS-VDAT Adapter (HPE Part Number: P10180-B21)</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>New features and changes in version 4.17.71.1:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Disabled the option of shutting down the link due to power limitation.</p>\n\t</li>\n\t<li>\n\t<p>Support for trusting Differentiated Services Code Point (DSCP) and setting default value for RoCE traffic.</p>\n\t</li>\n\t<li>\n\t<p>New counter that enables the user to query per Virtual Function counters.</p>\n\t</li>\n\t<li>\n\t<p>RX out-of-buffer counter to indicate any lack of software receive buffers.</p>\n\t</li>\n\t<li>\n\t<p>Module parameter to enforce specific RoCE version.</p>\n\t</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version&nbsp;in 4.17.71.1:</strong></p>\n\n<ul>\n\t<li>\n\t<p>The &quot;esxcli network sriovnic vf stats&quot; command&nbsp;was not supported.When running this command on a &quot;vmknic&quot;, a failure message&nbsp;was displayed.</p>\n\t</li>\n\t<li>\n\t<p>IPv6 as inner packet was not supported.</p>\n\t</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"","value":"HPE Apollo kl20 Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"","value":"HPE Apollo am35 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo pc40 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"","value":"HPE Apollo sx40 Server"}],"sw_keys":[{"name":"nmlx5-core:4.17.71.1-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"nmlx5-rdma:4.17.71.1-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900083","languages":[{"lang":"tw","x_late":"韌體 ─ 電源管理"},{"lang":"en","x_late":"Firmware - Power Management"},{"lang":"ko","x_late":"펌웨어 - 전원 관리"},{"lang":"ja","x_late":"ファームウェア - パワー マネジメント"},{"lang":"cn","x_late":"固件 - 电源管理"}]}],"description":[{"lang":"tw","x_late":"此元件可更新電源管理控制器韌體。 "},{"lang":"en","x_late":"This component updates the Power Management Controller firmware. "},{"lang":"ko","x_late":"이 구성 요소는 전원 관리 컨트롤러 펌웨어를 업데이트합니다. "},{"lang":"cn","x_late":"该组件更新电源管理控制器固件。 "},{"lang":"ja","x_late":"このコンポーネントは、Power Management Controllerファームウェアをアップデートします。 "}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"755141","datemodified":"2015-05-14T11:14:09","file_list":["/CP026094.vmexe","/CP026094.vmfile","/CP026094.xml","/README.txt"],"md5sum":"0266ff4b77c423a56923408aeb074593","name":"CP026094.zip","release":"2015-05-14T11:17:04","revision":"0","sha1sum":"ccb48c08a6a7e7da0af90eeea322d1305d7abbc0","size":"737KB","target_guids":[],"type_of_change":"1","version":"4.1","vib_list":[]}],"id":{"product":"7fe0be6bb4504cf8abf7b5506059ca0a","version":"a455d6842b1144f399a1073e29a83e6c"},"installation":{"command":"cpqsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"tw","x_late":"<p>  重要提示： 此元件要求先載入 CRU 驅動程式，後然才能執行。此外，CRU 驅動程式有最低版本要求。<br />\n <br /> <strong>若要使用適用於 vCenter 的 HP Insight Control：</strong></p>\n<ul>\n <li>   登入 vSphere 用戶端。</li>\n <li>   在詳細目錄樹狀結構中選取伺服器或叢集。</li>\n <li>   按一下「HP Insight Management (HP Insight 管理)」標籤。</li>\n <li>   遵循適用於 vCenter 的 Insight Control 的步驟，使用智慧型元件更新韌體</li>\n <li>   有關適用於 vCenter 的 Insight Control 連結資訊，包含其說明文件： <a href=\"http://www.hp.com/go/icvcenter\">http://www.hp.com/go/icvcenter</a></li>\n <li>   有關「在 HP ProLiant 伺服器中部署與更新 VMware vSphere 5.0 白皮書」的連結，包含如何使用適用於 vCenter 的 Insight Control 以更新韌體的資訊： <a href=\"http://h20000.www2.hp.com/bc/docs/support/SupportManual/c03285134/c03285134.pdf\">http://h20000.www2.hp.com/bc/docs/support/SupportManual/c03285134/c03285134.pdf</a></li>\n</ul>\n<p>\n <br />  <strong>從目標伺服器上的 VMware ESXi 作業系統更新韌體：</strong></p>\n<ul>\n <li>   在 ESXi 主機上啟用技術支援模式。</li>\n <li>   以 root 身份登入。(您必須以 root 身份才能套用 ROM 更新)。</li>\n <li>   請將智慧型元件置於暫存目錄中。</li>\n <li>   從相同的目錄執行智慧型元件。例如： ./CPXXXXXX.scexe</li>\n <li>   請依照智慧型元件所提示的相關指示進行。</li>\n <li>   在 ESXi 主機上停用技術支援模式</li>\n <li>   如有需要，重新啟動您的系統使更新立即生效。</li>\n</ul>\n<ul>\n</ul>\n"},{"lang":"en","x_late":"<p>\n IMPORTANT: This component requires that the CRU driver be loaded before the component can run. Moreover, there is a minimum version requirement for the CRU driver.<br />\n <br />\n <strong>To use HP Insight Control for vCenter :</strong></p>\n<ul>\n <li>\n  Log in to the vSphere Client.</li>\n <li>\n  Select a server or cluster in the inventory tree.</li>\n <li>\n  Click the HP Insight Management tab.</li>\n <li>\n  Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n <li>\n  Link to information about Insight Control for vCenter, including its documentation: <a href=\"http://www.hp.com/go/icvcenter\">http://www.hp.com/go/icvcenter</a></li>\n <li>\n  Link to &ldquo;Deploying and updating VMware vSphere 5.0 on HP ProLiant Servers White Paper&rdquo; that includes information of how to use Insight Control for vCenter to update firmware: <a href=\"http://h20000.www2.hp.com/bc/docs/support/SupportManual/c03285134/c03285134.pdf\">http://h20000.www2.hp.com/bc/docs/support/SupportManual/c03285134/c03285134.pdf</a></li>\n</ul>\n<p>\n <br />\n <strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n<ul>\n <li>\n  Enable Tech Support Mode on the ESXi host.</li>\n <li>\n  Login as root. (You must be root in order to apply the ROM update.)</li>\n <li>\n  Place the Smart Component in a temporary directory.</li>\n <li>\n  From the same directory, execute the Smart Component. For example: ./CPXXXXXX.scexe</li>\n <li>\n  Follow the directions given by the Smart Component.</li>\n <li>\n  Disable Tech Support Mode on the ESXi host</li>\n <li>\n  If required, reboot your system for the update to take effect immediately.</li>\n</ul>\n<ul>\n</ul>\n"},{"lang":"ko","x_late":"<p>  중요: 이 구성 요소를 사용하려면 구성 요소를 실행하기 전에 CRU 드라이버를 로드해야 합니다. 또한 CRU 드라이버에 대한 최소 버전 요구 사항이 있습니다.<br />\n <br /> <strong>vCenter용 HP Insight Control 사용 방법:</strong></p>\n<ul>\n <li>   vSphere 클라이언트로 로그인합니다.</li>\n <li>   인벤토리 트리에서 서버 또는 클러스터를 선택합니다.</li>\n <li>   HP Insight Management 탭을 클릭합니다.</li>\n <li>   vCenter용 Insight Control 절차에 따라 스마트 구성 요소를 사용하여 펌웨어를 업데이트합니다.</li>\n <li>   문서를 포함하여 vCenter용 Insight Control의 정보의 링크: <a href=\"http://www.hp.com/go/icvcenter\">http://www.hp.com/go/icvcenter</a></li>\n <li>   vCenter용 Insight Control을 사용하여 펌웨어를 업데이트하는 방법에 대한 정보가 포함되어 있는 \"HP ProLiant 서버에 VMware vSphere 5.0 배포 및 업데이트 백서\"의 링크: <a href=\"http://h20000.www2.hp.com/bc/docs/support/SupportManual/c03285134/c03285134.pdf\">http://h20000.www2.hp.com/bc/docs/support/SupportManual/c03285134/c03285134.pdf</a></li>\n</ul>\n<p>\n <br />  <strong>대상 서버의 VMware ESXi 운영 체제에서 펌웨어를 업데이트하는 방법:</strong></p>\n<ul>\n <li>   ESXi 호스트에서 Tech Support Mode(기술 지원 모드)를 활성화합니다.</li>\n <li>   루트로 로그인합니다. (ROM 업데이트를 적용하려면 반드시 루트 계정을 사용해야 합니다.)</li>\n <li>   스마트 구성 요소를 임시 디렉터리에 저장합니다.</li>\n <li>   동일한 디렉터리에서 스마트 구성 요소를 실행합니다. 예: ./CPXXXXXX.scexe</li>\n <li>   스마트 구성 요소의 설명에 따라 진행합니다.</li>\n <li>   ESXi 호스트에서 Tech Support Mode(기술 지원 모드)를 비활성화합니다.</li>\n <li>   필요한 경우 업데이트를 즉시 적용하려면 시스템을 다시 부팅합니다.</li>\n</ul>\n<ul>\n</ul>\n"},{"lang":"cn","x_late":"<p>  重要信息： 运行该组件前需载入CRU驱动程序。此外，还对CRU驱动程序最低版本有要求。<br />\n <br /> <strong>如要使用 HP Insight Control for vCenter：</strong></p>\n<ul>\n <li>   登录 vSphere 客户端。</li>\n <li>   选择库存树中的服务器或集群。</li>\n <li>   点击 HP Insight Management 选项卡。</li>\n <li>   使用智能组件，按照 Insight Control for vCenter 中的步骤更新固件</li>\n <li>   用于vCenter的Insight控制的信息及其文档，其链接地址是： <a href=\"http://www.hp.com/go/icvcenter\">http://www.hp.com/go/icvcenter</a></li>\n <li>   “在HP ProLiant服务器上部署和升级VMware vSphere 5.0白皮书”，包括如何使用用于vCenter的Insight控制更新固件，其链接地址是： <a href=\"http://h20000.www2.hp.com/bc/docs/support/SupportManual/c03285134/c03285134.pdf\">http://h20000.www2.hp.com/bc/docs/support/SupportManual/c03285134/c03285134.pdf</a></li>\n</ul>\n<p>\n <br />  <strong>在运行 VMware ESXi 操作系统的目标服务器上更新固件：</strong></p>\n<ul>\n <li>   启用 ESXi 主机的“技术支持模式”。</li>\n <li>   以根用户身份登录。（必须以根用户身份登录才能应用 ROM 更新。）</li>\n <li>   将 Smart Component 存放到一个临时目录中。</li>\n <li>   在该目录下执行 Smart Component。例如： ./CPXXXXXX.scexe</li>\n <li>   按照 Smart Component 提供的说明执行操作。</li>\n <li>   禁用 ESXi 主机的“技术支持模式”</li>\n <li>   如有要求，请重新启动您的系统以使更改生效。</li>\n</ul>\n<ul>\n</ul>\n"},{"lang":"ja","x_late":"<p>\n 重要： このコンポーネントは、実行する前にCRUドライバーがロードされている必要があります。 また、CRUドライバーの最小バージョン要件があります。<br /> <br /> <strong>HP Insight Control for vCenterを使用するには、以下の手順に従ってください。</strong></p>\n<ul>\n <li>\n  vSphereクライアントにログインします。</li>\n <li>\n  インベントリツリーのサーバーまたはクラスターを選択します。</li>\n <li>\n  HP Insight Managementタブをクリックします。</li>\n <li>\n  Insight Control for vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います。</li>\n <li>\n  Insight Control for vCenterについてのドキュメントを含む情報へのリンク: <a href=\"http://www.hp.com/go/icvcenter\">http://www.hp.com/go/icvcenter</a></li>\n <li>\n  Insight Control for vCenterを使ってファームウェアをアップデートする方法についての情報を含む、“Deploying and updating VMware vSphere 5.0 on HP ProLiant Servers White Paper”へのリンク: <a href=\"http://h20000.www2.hp.com/bc/docs/support/SupportManual/c03285134/c03285134.pdf\">http://h20000.www2.hp.com/bc/docs/support/SupportManual/c03285134/c03285134.pdf</a>（英語）</li>\n</ul>\n<p>\n <br /> <strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n<ul>\n <li>\n  ESXiホスト上のTech Support Modeを有効にします。</li>\n <li>\n  rootとしてログインします。 （ROMアップデートを適用するにはrootとしてログインする必要があります）</li>\n <li>\n  Smartコンポーネントをテンポラリディレクトリに置きます。</li>\n <li>\n  同じディレクトリからSmartコンポーネントを実行します。 例: ./CPXXXXXX.scexe</li>\n <li>\n  Smartコンポーネントの指示に従います。</li>\n <li>\n  ESXiホスト上のTech Support Modeを無効にします。</li>\n <li>\n  必要な場合、アップデートを直ちに有効にするにはシステムを再起動します。</li>\n</ul>\n<ul>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"tw","x_late":"適用於 VMware ESXi 的線上 ROM 更新 - 電源管理控制器 "},{"lang":"en","x_late":"Online ROM Flash for VMware ESXi - Power Management Controller "},{"lang":"ko","x_late":"VMware ESXi용 온라인 ROM 플래시 - 전원 관리 컨트롤러 "},{"lang":"cn","x_late":"VMware ESXi版在线ROM刷新 - 电源管理控制器 "},{"lang":"ja","x_late":"オンラインROMフラッシュ for VMware ESXi - Power Management Controller "}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"5","minor":"1","name":"VMware vSphere 5.1","platform":"vmware_esx_server","sr":"OEM"},{"major":"5","minor":"5","name":"VMware vSphere 5.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2015-03-19T17:33:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>\n <b>Important Notes:</b><br />\n Ver. 4.1(D) contains updates to the OS installation support for HP Smart Update Manager. The Power Management Controller Firmware contained within Ver. 4.1(D) is Ver. 4.1. Therefore, it is not necessary to upgrade with ver. 4.1(D), if the Power Management Controller firmware version is 4.1.<br />\n <b>Firmware Dependencies:</b></p>\nNone\n<p>\n <strong>Enhancements/New Features:</strong><br />\n This is the initial version of the firmware.<br />\n <b><b>Known Issues:</b></b><br />\n The smart component prompts for reboot unnecessarily when the installation procedure is completed. Reboot is not required after installation for updates to take effect and hardware stability to be maintained.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>Ver.&nbsp;4.1 (E) contains updates to the component packaging and is functionally equivalent to ver. 4.1. It is not necessary to upgrade with Revision&nbsp;E if a previous component Revision was used to upgrade the firmware to version 4.1.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>This is the initial version of the firmware.</p>\n\n<p><strong><strong>Known Issues:</strong></strong></p>\n\n<p>The smart component prompts for reboot unnecessarily when the installation procedure is completed. Reboot is not required after installation for updates to take effect and hardware stability to be maintained.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HP ProLiant DL580 Gen9 Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"}],"sw_keys":[{"name":"PowerPIC-DL580","sw_key_expectedpath":"firmware:QLOGIC"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"nmlx5 is the low level driver implementation for the ConnectX®-4 and ConnectX®-5 adapters for VMware ESXi 7.0 U2 Mellanox Ethernet Adapters."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"915425","datemodified":"2021-08-27T07:00:22","file_list":["/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880-package.zip","/cp047641.xml","/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880-package.zip/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880.zip","/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880-package.zip/doc/README.txt","/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880-package.zip/doc/release_note_nmlx5-core_4.21.71.101-1OEM.702.0.0.17630552.pdf","/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880-package.zip/doc/release_note_nmlx5-rdma_4.21.71.101-1OEM.702.0.0.17630552.pdf","/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880-package.zip/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880.zip/index.xml","/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880-package.zip/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880.zip/vendor-index.xml","/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880-package.zip/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880.zip/metadata.zip","/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880-package.zip/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880.zip/vib20/nmlx5-rdma/MEL_bootbank_nmlx5-rdma_4.21.71.101-1OEM.702.0.0.17630552.vib","/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880-package.zip/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880.zip/vib20/nmlx5-core/MEL_bootbank_nmlx5-core_4.21.71.101-1OEM.702.0.0.17630552.vib","/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880-package.zip/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880.zip/metadata.zip/vendor-index.xml","/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880-package.zip/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880.zip/metadata.zip/vmware.xml","/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880-package.zip/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880.zip/metadata.zip/vibs/nmlx5-rdma--2387361673357585997.xml","/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880-package.zip/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880.zip/metadata.zip/vibs/nmlx5-core--2146088624239958034.xml","/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880-package.zip/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880.zip/metadata.zip/bulletins/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552.xml"],"md5sum":"afd962dba0881ad2a9d54e0b45572c7e","name":"cp047641.zip","release":"2021-08-27T06:58:44","revision":"0","sha1sum":"9f602bd559a3a9fcad5b244b2fe3fe81dca38969","size":"893KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec41bd2821","20a6e8e4-bf33-4c71-a6bf-d9ecdebb2a48","20a6e8e4-bf33-4c71-a6bf-d9ec38df96d3"],"type_of_change":"1","version":"2021.04.21","vib_list":[{"name":"nmlx5-rdma","version":"4.21.71.101-1OEM.702.0.0.17630552"},{"name":"nmlx5-core","version":"4.21.71.101-1OEM.702.0.0.17630552"}]}],"id":{"product":"45e5e3b4b5524afa8388b9297cf98327","version":"79dfb058528a422eb2ec502ba9ef8fad"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Remote Online:&nbsp;</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the HPE USB Key Creator Utility.&nbsp;</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux .</li>\n\t<li>cd /SPP20xxxxx/ and launch SUM&nbsp;(launch_sum.bat for Windows and launch_sum.sh for Linux).</li>\n\t<li>Select &quot;Baseline Library&quot; and wait for the Baseline inventory to complete.</li>\n\t<li>Select &quot;Nodes&quot; from the &quot;Smart Update Manager x.x.x&quot; drop down.</li>\n\t<li>Click, &quot;Add Node&quot;.\n\t<ul>\n\t\t<li>If adding a Gen9 server,\n\t\t<ul>\n\t\t\t<li>Provide IP address of the ESXi host.</li>\n\t\t\t<li>Enter&nbsp;the ESXi host credentials (root or administrator username and password)&nbsp;</li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>If adding a Gen10 and above server,\n\t\t<ul>\n\t\t\t<li>Provide iLO IP address of the ESXi host server.</li>\n\t\t\t<li>Enter the iLO credentials of the ESXi host server.</li>\n\t\t</ul>\n\t\t</li>\n\t</ul>\n\t</li>\n\t<li>Follow&nbsp;Smart Update Manager Steps and complete the driver update.&nbsp;</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware VUM or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>リモートオンライン: </strong></p>\n\n<ol>\n\t<li>HPE USB Key Creator Utilityを使用して、SPPをUSBキーにコピーします。 </li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。</li>\n\t<li>cd /SPP20xxxxx/を実行し、SUMを起動します（Windowsの場合はlaunch_sum.bat、Linuxの場合は./launch_sum.sh）。</li>\n\t<li>\"ベースラインライブラリ\"を選択し、ベースラインインベントリが完了するのを待ちます。</li>\n\t<li>\"Smart Update Manager x.x.x\"ドロップダウンから\"ノード\"を選択します。</li>\n\t<li>\"ノードの追加\"をクリックします。\n\t<ul>\n\t\t<li>Gen9サーバーを追加する場合、\n\t\t<ul>\n\t\t\t<li>ESXiホストのIPアドレスを提供します。</li>\n\t\t\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します </li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>Gen10以降のサーバーを追加する場合、\n\t\t<ul>\n\t\t\t<li>ESXiホストサーバーのiLO IPアドレスを提供します。</li>\n\t\t\t<li>ESXiホストサーバーのiLO認証情報を入力します。</li>\n\t\t</ul>\n\t\t</li>\n\t</ul>\n\t</li>\n\t<li>Smart Update Managerの指示に従い、ドライバーのアップデートを完了します。 </li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li>\n\t<li>オフラインバンドルをインストールするために、VMware VUMまたはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"nmlx5_en Driver Component for VMware 7.0 U2"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"032D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-10171590032d","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30047","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"0221","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101315900221","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-21T10:57:04","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Changes and New Features are included&nbsp;in smart component version 2020.11.11:</strong></p>\n\n<ul>\n\t<li>Added support for the following adapters:\n\t<ul>\n\t\t<li>HPE Ethernet 200Gb 1-Port QSFP56 MCX623105AS-VDAT Adapter (HPE Part Number: P10180-B21)</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>New features and changes in version 4.19.70.1:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Disabled the option of shutting down the link due to power limitation.</p>\n\t</li>\n\t<li>\n\t<p>Support for trusting Differentiated Services Code Point (DSCP) and setting default value for RoCE traffic.</p>\n\t</li>\n\t<li>\n\t<p>New counter that enables the user to query per Virtual Function counters.</p>\n\t</li>\n\t<li>\n\t<p>RX out-of-buffer counter to indicate any lack of software receive buffers.</p>\n\t</li>\n\t<li>\n\t<p>support for Data Center Bridging Capability Exchange (DCBx) protocol.DCBX works with LLDP to allow switches to exchange information about their Data Center Bridging (DCB) capabilities and configuration and automatically</p>\n\n\t<p>negotiate common Priority-Based Flow Control (PFC) parameters.</p>\n\t</li>\n\t<li>\n\t<p>Module parameter to enforce specific RoCE version.</p>\n\t</li>\n\t<li>\n\t<p>Support for setting the minimal bandwidth guarantee for traffic classes (TCs).</p>\n\t</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>Changes and New Features are included&nbsp;in smart component version 2021.04.21:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>vSan over RDMA.</li>\n\t\t<li>Receive Side Scaling (RSS) for ENS model 0.</li>\n\t\t<li>200GbE link speed.</li>\n\t\t<li>ConnectX-6 Lx devices.</li>\n\t\t<li>Scaled support for up to 10K connections over RDMA networks</li>\n\t\t<li>Data Center Bridging Capability Exchange (DCBX) protocol with hardware offload.</li>\n\t\t<li>sriov_mc_isolation module parameter to isolate multicast traffic to SR-IOV interfaces. Default value is OFF.</li>\n\t\t<li>ens_fallback_model to set the default fallback mode when the option to query ENS model from the OS is no supported. Default to Model 1.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>New features and changes in version 4.21.71.101:</strong></p>\n\n<ul>\n\t<li>\n\t<p>SR-IOV InfiniBand is at GA level.</p>\n\t</li>\n\t<li>\n\t<p>Updated the supported_num_ports default value to 1 to lower memory constraints.<br />\n\tNote: The user must set a value corresponding to the amount of ports installed in the system.</p>\n\t</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Fixes&nbsp;included in version 4.21.71.101:</strong></p>\n\n<ul>\n\t<li>Fixed a compatibility issue with VMware Update Manager as it wouldn&#39;t accept a bundle with metadata xml with old versioning scheme. The metadata xml now contains the new versioning scheme.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"","value":"HPE Apollo kl20 Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"","value":"HPE Apollo am35 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo pc40 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"","value":"HPE Apollo sx40 Server"}],"sw_keys":[{"name":"nmlx5-core:4.21.71.101-1OEM.702.0.0.17630552","sw_key_expectedpath":"driver:vmware:zip"},{"name":"nmlx5-rdma:4.21.71.101-1OEM.702.0.0.17630552","sw_key_expectedpath":"driver:vmware:zip"},{"name":"Mellanox-nmlx5:4.21.71.101-1OEM.702.0.0.17630552","sw_key_expectedpath":"driver.component:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6126547","datemodified":"2021-05-18T02:47:08","file_list":["./usr/lib/i386-linux-gnu/firmware-system-p85-2.90_2021_04_29-1.1","./usr/lib/i386-linux-gnu/firmware-system-p85-2.90_2021_04_29-1.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-system-p85-2.90_2021_04_29-1.1/.setup","./usr/lib/i386-linux-gnu/firmware-system-p85-2.90_2021_04_29-1.1/CP047851.xml","./usr/lib/i386-linux-gnu/firmware-system-p85-2.90_2021_04_29-1.1/P85_2.90_04_29_2021.signed.flash","./usr/lib/i386-linux-gnu/firmware-system-p85-2.90_2021_04_29-1.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-system-p85-2.90_2021_04_29-1.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP047851.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP047851.scexe"],"md5sum":"741f71996927f547d21d8d875ff4d8e6","name":"firmware-system-p85-2.90_2021_04_29-1.1.i386.rpm","release":"2021-05-18T02:38:05","revision":"0","sha1sum":"f9ebd2ed9c39a24f0fb81def7e6542dadfe72c2d","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021"}],"id":{"product":"68ce71d480544726b13cf1bf182ff422","version":"8b082792e24040f4a90349e27d150d12"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HPE ProLiant Agentless Management Service (<strong>AMS</strong>) and HPE SNMP Agents (<strong>SNMP Agents</strong>) are both running.&nbsp; HPE does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager 8.0.0 or later, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、iLOとの通信ができない場合に失敗します。  これは、HPE ProLiant Agentless Management Service (<strong>AMS</strong>)およびHPE SNMPエージェント(<strong>SNMP Agents</strong>)の両方が実行されているときに発生します。  HPEでは、AMSおよびSNMPエージェントを同時に実行させないことを推奨します。  「iLO device not found」エラーが発生した場合、AMSまたはSNMPエージェントを停止させて、再度フラッシュコンポーネントを実行します。<br />\n<br />\n<br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上のSmart Update Manager 8.0.0以降を使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant DL560 Gen9 (P85) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant DL560 Gen9(P85)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Oracle Linux 6 (AMD64/EMT64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Oracle Linux 7","platform":"Oracle Enterprise Linux","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-05T03:51:43","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","latest_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390.  These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"}],"sw_keys":[{"name":"P85","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800026","languages":[{"lang":"tw","x_late":"軟體 - 管理"},{"lang":"en","x_late":"Software - Management"},{"lang":"ko","x_late":"소프트웨어 - 관리"},{"lang":"cn","x_late":"软件 - 管理"},{"lang":"ja","x_late":"ソフトウェア - マネジメント"}]}],"description":[{"lang":"en","x_late":"The HPE ESXi CRU Driver Smart Component for ESXi 7.0 includes the latest HPE CRU Driver. The HPE CRU Driver provides hardware memory and PCI Config Space access to HPE Server Configuration tools and firmware flash components."},{"lang":"ja","x_late":"HPE ESXi CRU ドライバー Smartコンポーネント for ESXi 7.0には、最新のHPE CRUドライバーが含まれています。HPE CRUドライバーは、HPEサーバー構成ツールおよびファームウェアフラッシュコンポーネントへのハードウェアメモリおよびPCI構成スペースアクセスを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]}],"documentation":[],"files":[{"bytes":"21644","datemodified":"2020-06-17T18:54:49","file_list":["/cp044598.xml","/cru_driver_700.10.16_1OEM.700.0.0.14828939_signed_component_15675715.zip","/cru_driver_700.10.16_1OEM.700.0.0.14828939_signed_component_15675715.zip/index.xml","/cru_driver_700.10.16_1OEM.700.0.0.14828939_signed_component_15675715.zip/vendor-index.xml","/cru_driver_700.10.16_1OEM.700.0.0.14828939_signed_component_15675715.zip/metadata.zip","/cru_driver_700.10.16_1OEM.700.0.0.14828939_signed_component_15675715.zip/vib20/cru/HPE_bootbank_cru_700.10.16-1OEM.700.0.0.14828939.vib","/cru_driver_700.10.16_1OEM.700.0.0.14828939_signed_component_15675715.zip/metadata.zip/vendor-index.xml","/cru_driver_700.10.16_1OEM.700.0.0.14828939_signed_component_15675715.zip/metadata.zip/vmware.xml","/cru_driver_700.10.16_1OEM.700.0.0.14828939_signed_component_15675715.zip/metadata.zip/vibs/cru--3587722627266947823.xml","/cru_driver_700.10.16_1OEM.700.0.0.14828939_signed_component_15675715.zip/metadata.zip/bulletins/cru-driver_700.10.16-1OEM.700.0.0.14828939.xml"],"md5sum":"b15fcccba65f1a201e75668f7235c216","name":"cp044598.zip","release":"2020-06-17T18:54:04","revision":"0","sha1sum":"1062a6263027ebed11f844c940fdd7d86fcde628","size":"21KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecab5ae383","20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6"],"type_of_change":"1","version":"2020.04.01","vib_list":[{"name":"cru","version":"700.10.16-1OEM.700.0.0.14828939"}]}],"id":{"product":"2bca574323fb4462b57e23c3b359f69c","version":"2310590f205e43e0ae97f59492d0a40a"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To&nbsp;remotely install&nbsp;this&nbsp;bundle&nbsp; online using the HP Smart Update Manager (HPSUM) from the HP Service Pack for ProLiant (SPP):</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\">HPE USB Key Utility</a>.</li>\n\t<li>Copy&nbsp;this driver component&nbsp;to the directory<em> /SPP20xxxxx/hp/swpackages</em> on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.</li>\n\t<li>Change directories to <em>/hp/swpackages</em> and execute&nbsp;./hpsum.</li>\n\t<li>Select the &quot;next&quot; button.</li>\n\t<li>Click &quot;Add Single Target.&quot;</li>\n\t<li>Enter&nbsp;the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow HP Smart Update Manager&nbsp;instructions&nbsp;to complete the driver update.</li>\n</ol>\n\n<p><br />\n<strong>To&nbsp;install this bundle using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the component zip file to extract the driver offline bundle.</li>\n\t<li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li>\n</ol>\n\n<p>Refer to VMware documentation for information on the esxcli commands</p>\n"},{"lang":"ja","x_late":"<p><strong>HP Service Pack for ProLiant (SPP)からHP Smart Update Manager (HPSUM)を使用して、このバンドルをオンラインでリモートインストールするには：</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\">HPE USB Key Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>このドライバーコンポーネントをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバーにUSBキーをマウントします。</li>\n\t<li><em>/hp/swpackages</em>にディレクトリを変更し、./hpsumを実行します。</li>\n\t<li>「次へ」ボタンを選択します。</li>\n\t<li>「シングルターゲットの追加」をクリックします。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>HP Smart Update Manager 手順に従って、ドライバーアップデートを完了します。</li>\n</ol>\n\n<p><br />\n<strong>VMwareツールを使用して、このバンドルをインストールするには：</strong></p>\n\n<ol>\n\t<li>ドライバーオフラインバンドルを抽出するために、このコンポーネントのzipファイルを解凍します。</li>\n\t<li>オフラインバンドルをインストールするには、「esxcli」コマンドを実行します。</li>\n</ol>\n\n<p>esxcliコマンドの詳細については、VMwareのドキュメントを参照してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE CRU Driver Bundle Smart Component for ESXi 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"16"},"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-17T18:45:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Support&nbsp;for VMware ESXi 7.0</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Add new supported servers</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"cru-driver:700.10.16-1OEM.700.0.0.14828939","sw_key_expectedpath":"driver.component:vmware:zip"},{"name":"cru:700.10.16-1OEM.700.0.0.14828939","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000GCWLT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HMKPB6G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304743574c54","Version":"HPG4"},{"DeviceName":"MB3000GCWLU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HMKPB6G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304743574c55","Version":"HPG4"},{"DeviceName":"MB4000GCWLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HMKPB6G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304743574c56","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB2000GCWLT, MB3000GCWLU and MB4000GCWLV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB2000GCWLT, MB3000GCWLU&nbsp;and MB4000GCWLV Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"16820495","datemodified":"2021-08-26T18:37:45","file_list":["/CP048345_BUILD_2.data","/CP048345.vmexe","/CP048345.vmexe64","/CP048345.vmfile","/CP048345_VMw.zip","/CP048345.xml","/payload.json","/CP048345_VMw.zip/index.xml","/CP048345_VMw.zip/vendor-index.xml","/CP048345_VMw.zip/metadata.zip","/CP048345_VMw.zip/vib20/CP048345/HPE_bootbank_CP048345_HPG4.2-7.0.0.15843807.vib","/CP048345_VMw.zip/metadata.zip/vendor-index.xml","/CP048345_VMw.zip/metadata.zip/vmware.xml","/CP048345_VMw.zip/metadata.zip/vibs/CP048345-1026262613694912961.xml","/CP048345_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048345_HPG4.2-7.0.0.15843807.xml"],"md5sum":"5ba86e478b2a2d21a60f324df2069b15","name":"CP048345.zip","release":"2021-08-26T18:32:42","revision":"0","sha1sum":"6466131bcac001fd3fe4dd1634436bfa0cb3288a","size":"16MB","target_guids":["002340a5-4d00-3242-3030-304743574c54","002340a5-4d00-3342-3030-304743574c55","002340a5-4d00-3442-3030-304743574c56"],"type_of_change":"1","version":"HPG4","vib_list":[{"name":"CP048345","version":"HPG4.2-7.0.0.15843807"}]}],"id":{"product":"3a074b488c7143aaa5904bb4840ab9e0","version":"b21ca4feede748b3a7db8f80e38e57bc"},"installation":{"command":"CP040507.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB2000GCWLT, MB3000GCWLU and MB4000GCWLV Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB2000GCWLT、MB3000GCWLU、およびMB4000GCWLVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"MB2000GCWLT","target_guid":"002340a5-4d00-3242-3030-304743574c54","type":"sata"},{"id":"MB3000GCWLU","target_guid":"002340a5-4d00-3342-3030-304743574c55","type":"sata"},{"id":"MB4000GCWLV","target_guid":"002340a5-4d00-3442-3030-304743574c56","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-06T17:27:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000GCWLV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB2000GCWLT","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB3000GCWLU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware for Converged Network and Network only adapters. "}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"12980352","datemodified":"2021-08-25T11:59:58","file_list":["/CP048536_BUILD_4.data","/CP048536.vmexe","/CP048536.vmexe64","/CP048536.vmfile","/CP048536_VMw.zip","/CP048536.xml","/payload.json","/CP048536_VMw.zip/index.xml","/CP048536_VMw.zip/vendor-index.xml","/CP048536_VMw.zip/metadata.zip","/CP048536_VMw.zip/vib20/CP048536/HPE_bootbank_CP048536_2021.10.01.4-6.5.0.4240417.vib","/CP048536_VMw.zip/metadata.zip/vendor-index.xml","/CP048536_VMw.zip/metadata.zip/vmware.xml","/CP048536_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048536_2021.10.01.4-6.5.0.4240417.xml","/CP048536_VMw.zip/metadata.zip/vibs/CP048536--1923484123725619038.xml"],"md5sum":"4b9a4b33ad36466fcc8921ddcc5a9417","name":"CP048536.zip","release":"2021-08-25T11:54:09","revision":"0","sha1sum":"7f88e9887d1272e092ed957120c7e9401380b0e7","size":"12MB","target_guids":[],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"CP048536","version":"2021.10.01.4-6.5.0.4240417"}]}],"id":{"product":"0fc3cdd1bfb347259d943cf6f00a2872","version":"64260e38bd7a4dcbba7358b6f4275bd7"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the&nbsp;Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, <strong>if the component is supported by SUM but is not yet part of an SPP:</strong></strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Converged Network Adapters for VMware vSphere  6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"20000"},"supported_devices":[{"dev":"0724","subdev":"21D4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"21D4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"8153","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8153","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8144","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"8144","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"220A","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"220A","subven":"103C","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T11:00:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This Firmware package contains following firmware version:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:800px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot BIOS</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 10Gb 2-port 556FLR-T Adapter</td>\n\t\t\t<td>10Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1345.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</td>\n\t\t\t<td>10Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1345.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE CN1200E Dual Port Converged Network Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1345.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE&nbsp;CN1200E-T Dual Port Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1345.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"}],"sw_keys":[{"name":"emulex_cna","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK0120GFDKE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3132-304746444b45","Version":"HPG1"},{"DeviceName":"VK0240GFDKF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3234-304746444b46","Version":"HPG1"},{"DeviceName":"VK0480GFDKH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3438-304746444b48","Version":"HPG1"},{"DeviceName":"VK0960GFDKK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3936-304746444b4b","Version":"HPG1"},{"DeviceName":"VK1920GFDKL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314b-3932-304746444b4c","Version":"HPG1"},{"DeviceName":"VK3840GFDKN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-334b-3834-304746444b4e","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: VK0120GFDKE, VK0240GFDKF, VK0480GFDKH, VK0960GFDKK, VK1920GFDKL and VK3840GFDKN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;VK0120GFDKE, VK0240GFDKF, VK0480GFDKH, VK0960GFDKK, VK1920GFDKL and VK3840GFDKN Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp; &nbsp;&nbsp; None&nbsp;<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"2784720","datemodified":"2021-07-25T19:15:32","file_list":["cp048641.xml","cpqsetup.exe","GPM863G1.rel","payload.json","setup.dll"],"md5sum":"553eadb759586865d0f2566181a9f830","name":"cp048641.exe","release":"2021-07-25T19:08:04","revision":"0","sha1sum":"453080f87a0eeb70260d5b2fdebc395ae8c83c48","size":"2MB","target_guids":["002340a5-5600-304b-3132-304746444b45","002340a5-5600-304b-3234-304746444b46","002340a5-5600-304b-3438-304746444b48","002340a5-5600-304b-3936-304746444b4b","002340a5-5600-314b-3932-304746444b4c","002340a5-5600-334b-3834-304746444b4e"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"3aebaee5a0504648985c2d89d7e4e8d9","version":"e01d85bf4bd649d4a9d3adc6e928d1db"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK0120GFDKE, VK0240GFDKF, VK0480GFDKH, VK0960GFDKK, VK1920GFDKL and VK3840GFDKN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - VK0120GFDKE、VK0240GFDKF、VK0480GFDKH、VK0960GFDKK、VK1920GFDKL、およびVK3840GFDKNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VK0120GFDKE","target_guid":"002340a5-5600-304b-3132-304746444b45","type":"sata"},{"id":"VK1920GFDKL","target_guid":"002340a5-5600-314b-3932-304746444b4c","type":"sata"},{"id":"VK0240GFDKF","target_guid":"002340a5-5600-304b-3234-304746444b46","type":"sata"},{"id":"VK3840GFDKN","target_guid":"002340a5-5600-334b-3834-304746444b4e","type":"sata"},{"id":"VK0480GFDKH","target_guid":"002340a5-5600-304b-3438-304746444b48","type":"sata"},{"id":"VK0960GFDKK","target_guid":"002340a5-5600-304b-3936-304746444b4b","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T17:22:33","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK0960GFDKK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0120GFDKE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0480GFDKH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK1920GFDKL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK3840GFDKN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0240GFDKF","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000960JWSSQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304a57535351","Version":"HPD8"},{"DeviceName":"VK001920JWSSR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304a57535352","Version":"HPD8"},{"DeviceName":"VK003840JWSST","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304a57535354","Version":"HPD8"},{"DeviceName":"VK007680JWSSU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-304a57535355","Version":"HPD8"},{"DeviceName":"VO015300JWSSV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3330-304a57535356","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000960JWSSQ, VK001920JWSSR, VK003840JWSST, VK007680JWSSU and VO015300JWSSV"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000960JWSSQ、VK001920JWSSR、VK003840JWSST、VK007680JWSSUおよびVO015300JWSSV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi&nbsp;- VK000960JWSSQ, VK001920JWSSR, VK003840JWSST, VK007680JWSSU and VO015300JWSSV&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16795581","datemodified":"2021-08-27T13:13:59","file_list":["/CP048446_BUILD_4.data","/CP048446.vmexe","/CP048446.vmexe64","/CP048446.vmfile","/CP048446_VMw.zip","/CP048446.xml","/payload.json","/CP048446_VMw.zip/index.xml","/CP048446_VMw.zip/vendor-index.xml","/CP048446_VMw.zip/metadata.zip","/CP048446_VMw.zip/vib20/CP048446/HPE_bootbank_CP048446_HPD8.4-7.0.0.15843807.vib","/CP048446_VMw.zip/metadata.zip/vendor-index.xml","/CP048446_VMw.zip/metadata.zip/vmware.xml","/CP048446_VMw.zip/metadata.zip/vibs/CP048446-5595848961480351804.xml","/CP048446_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048446_HPD8.4-7.0.0.15843807.xml"],"md5sum":"6789b713f4da7a58dc295aa60d0eb4a2","name":"CP048446.zip","release":"2021-08-27T13:09:13","revision":"0","sha1sum":"5723a338fb4f05fa92b1fbb5d173c4562d3c6dac","size":"16MB","target_guids":["562340a5-304b-3030-3936-304a57535351","562340a5-304b-3130-3932-304a57535352","562340a5-304b-3330-3834-304a57535354","562340a5-304b-3730-3638-304a57535355","562340a5-304f-3531-3330-304a57535356"],"type_of_change":"2","version":"HPD8","vib_list":[{"name":"CP048446","version":"HPD8.4-7.0.0.15843807"}]}],"id":{"product":"b197b25ba5a84d17992b28174218a00a","version":"4d0c314d79894a1599b4b9039e0ed937"},"installation":{"command":"CP042469.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします。</li>\n\t<li>CPXXXXXX.vmexe(ESXi 6.7 &以前のバージョン)およびCPXXXXXX.vmexe64(ESXi 7.0)は、次のコマンドを使用して実行可能です:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod x CPXXXXXX.vmexe    または    chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPXXXXXX.vmexe(または)./CPXXXXXX.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK000960JWSSQ, VK001920JWSSR, VK003840JWSST, VK007680JWSSU and VO015300JWSSV Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi -VK000960JWSSQ、 VK001920JWSSR、VK003840JWSST、VK007680JWSSUおよびVO015300JWSSVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VO015300JWSSV","target_guid":"562340a5-304f-3531-3330-304a57535356","type":"sas"},{"id":"VK007680JWSSU","target_guid":"562340a5-304b-3730-3638-304a57535355","type":"sas"},{"id":"VK003840JWSST","target_guid":"562340a5-304b-3330-3834-304a57535354","type":"sas"},{"id":"VK001920JWSSR","target_guid":"562340a5-304b-3130-3932-304a57535352","type":"sas"},{"id":"VK000960JWSSQ","target_guid":"562340a5-304b-3030-3936-304a57535351","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-10T15:22:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK001920JWSSR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO015300JWSSV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VK000960JWSSQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VK003840JWSST","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VK007680JWSSU","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000400KWDUK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3430-304b5744554b","Version":"HPK4"},{"DeviceName":"VK000480KWDUE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304b57445545","Version":"HPK4"},{"DeviceName":"MK000800KWDUL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3830-304b5744554c","Version":"HPK4"},{"DeviceName":"VK000960KWDUF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304b57445546","Version":"HPK4"},{"DeviceName":"MK001600KWDUN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3630-304b5744554e","Version":"HPK4"},{"DeviceName":"VK001920KWDUH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304b57445548","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MK000400KWDUK, VK000480KWDUE, MK000800KWDUL, VK000960KWDUF, MK001600KWDUN and VK001920KWDUH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for VMware ESXi -&nbsp;MK000400KWDUK, VK000480KWDUE, MK000800KWDUL, VK000960KWDUF, MK001600KWDUN&nbsp;and VK001920KWDUH Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"22807301","datemodified":"2021-08-31T04:15:14","file_list":["/CP048486_BUILD_2.data","/CP048486.vmexe","/CP048486.vmexe64","/CP048486.vmfile","/CP048486_VMw.zip","/CP048486.xml","/payload.json","/CP048486_VMw.zip/index.xml","/CP048486_VMw.zip/vendor-index.xml","/CP048486_VMw.zip/metadata.zip","/CP048486_VMw.zip/vib20/CP048486/HPE_bootbank_CP048486_HPK4.2-7.0.0.15843807.vib","/CP048486_VMw.zip/metadata.zip/vendor-index.xml","/CP048486_VMw.zip/metadata.zip/vmware.xml","/CP048486_VMw.zip/metadata.zip/vibs/CP048486--3255339833109693147.xml","/CP048486_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048486_HPK4.2-7.0.0.15843807.xml"],"md5sum":"04c181dfac8a39c5f0d731adb9892a68","name":"CP048486.zip","release":"2021-08-31T04:09:47","revision":"0","sha1sum":"413364a68fd1b1e371635059d32810d48b8bf544","size":"21MB","target_guids":["4d2340a5-304b-3030-3430-304b5744554b","562340a5-304b-3030-3438-304b57445545","4d2340a5-304b-3030-3830-304b5744554c","562340a5-304b-3030-3936-304b57445546","4d2340a5-304b-3130-3630-304b5744554e","562340a5-304b-3130-3932-304b57445548"],"type_of_change":"1","version":"HPK4","vib_list":[{"name":"CP048486","version":"HPK4.2-7.0.0.15843807"}]}],"id":{"product":"116d422873c94edd9b2d0af192be21c4","version":"910185cb75654051a8f0e72302b260fe"},"installation":{"command":"CP040919.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi  - MK000400KWDUK, VK000480KWDUE, MK000800KWDUL, VK000960KWDUF, MK001600KWDUN and VK001920KWDUH Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - MK000400KWDUK、VK000480KWDUE、MK000800KWDUL、VK000960KWDUF、MK001600KWDUN、およびVK001920KWDUHドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MK000400KWDUK","target_guid":"4d2340a5-304b-3030-3430-304b5744554b","type":"nvme"},{"id":"MK000800KWDUL","target_guid":"4d2340a5-304b-3030-3830-304b5744554c","type":"nvme"},{"id":"MK001600KWDUN","target_guid":"4d2340a5-304b-3130-3630-304b5744554e","type":"nvme"},{"id":"VK000480KWDUE","target_guid":"562340a5-304b-3030-3438-304b57445545","type":"nvme"},{"id":"VK000960KWDUF","target_guid":"562340a5-304b-3030-3936-304b57445546","type":"nvme"},{"id":"VK001920KWDUH","target_guid":"562340a5-304b-3130-3932-304b57445548","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-14T08:11:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK000960KWDUF","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK001920KWDUH","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK000800KWDUL","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK001600KWDUN","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK000400KWDUK","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK000480KWDUE","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900374","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware and boot BIOS of Emulex Fibre Channel host bus adapters."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"8338093","datemodified":"2021-08-25T13:27:18","file_list":["/CP048596_BUILD_9.data","/CP048596.vmexe","/CP048596.vmexe64","/CP048596.vmfile","/CP048596_VMw.zip","/CP048596.xml","/payload.json","/CP048596_VMw.zip/index.xml","/CP048596_VMw.zip/vendor-index.xml","/CP048596_VMw.zip/metadata.zip","/CP048596_VMw.zip/vib20/CP048596/HPE_bootbank_CP048596_2021.10.01.9-6.7.0.7535516.vib","/CP048596_VMw.zip/metadata.zip/vendor-index.xml","/CP048596_VMw.zip/metadata.zip/vmware.xml","/CP048596_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048596_2021.10.01.9-6.7.0.7535516.xml","/CP048596_VMw.zip/metadata.zip/vibs/CP048596--7405798078876345347.xml"],"md5sum":"8b07a4815af1fbe7dd3aa2f481509f11","name":"CP048596.zip","release":"2021-08-25T13:21:05","revision":"0","sha1sum":"cb02165b371339d6215f5c6ba521225a856ff8d3","size":"7MB","target_guids":[],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"CP048596","version":"2021.10.01.9-6.7.0.7535516"}]}],"id":{"product":"554c33c8b7644fb78acbb51680fbede9","version":"25ebc41874234a588e1ea967ab3fcb72"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated if the ESXi host is Gen9 Server or Enter the IP or DNS address of the iLO of the ESXi host if the Sever is Gen10 and above</li>\n\t<li>Enter the ESXi host/iLO credentials (root or administrator username and password) based on Gen9/Gen10 and above</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Fibre Channel Host Bus Adapters for VMware vSphere  6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"20000"},"supported_devices":[{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T10:35:39","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\" dir=\"LTR\" style=\"width:935px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Adapter</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Speed</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Universal Boot Image</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Firmware</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>UEFI</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Boot Bios</strong></p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE 81E 8Gb Single Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.80a3</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">2.10X6</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.183.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.9.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE 82E 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.80a3</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">2.10X6</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.183.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.9.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE 84E 8Gb Quad Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.80a3</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">2.10X6</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.183.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.9.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1000E 16Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1000E 16Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100E 16Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100E 16Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100E Quad Port 16Gb Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"emulex","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWTSV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757545356","Version":"HPG6"},{"DeviceName":"VK000480GWTTA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757545441","Version":"HPG6"},{"DeviceName":"VK000960GWTTB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757545442","Version":"HPG6"},{"DeviceName":"VK001920GWTTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757545443","Version":"HPG6"},{"DeviceName":"VK003840GWTTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304757545444","Version":"HPG6"},{"DeviceName":"MK000480GWTTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757545448","Version":"HPG6"},{"DeviceName":"MK000960GWTTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-30475754544b","Version":"HPG6"},{"DeviceName":"MK001920GWTTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475754544c","Version":"HPG6"},{"DeviceName":"MK003840GWTTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475754544e","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and&nbsp;MK003840GWTTN Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"16515980","datemodified":"2021-08-27T10:18:11","file_list":["/CP048408_BUILD_3.data","/CP048408.vmexe","/CP048408.vmexe64","/CP048408.vmfile","/CP048408_VMw.zip","/CP048408.xml","/payload.json","/CP048408_VMw.zip/index.xml","/CP048408_VMw.zip/vendor-index.xml","/CP048408_VMw.zip/metadata.zip","/CP048408_VMw.zip/vib20/CP048408/HPE_bootbank_CP048408_HPG6.3-7.0.0.15843807.vib","/CP048408_VMw.zip/metadata.zip/vendor-index.xml","/CP048408_VMw.zip/metadata.zip/vmware.xml","/CP048408_VMw.zip/metadata.zip/vibs/CP048408--799434529393724594.xml","/CP048408_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048408_HPG6.3-7.0.0.15843807.xml"],"md5sum":"8a9579504cd0880002d7f7128042891a","name":"CP048408.zip","release":"2021-08-27T10:12:48","revision":"0","sha1sum":"467805714e5410d2eebce66df6eef85255f362a9","size":"15MB","target_guids":["562340a5-304b-3030-3234-304757545356","562340a5-304b-3030-3438-304757545441","562340a5-304b-3030-3936-304757545442","562340a5-304b-3130-3932-304757545443","562340a5-304b-3330-3834-304757545444","4d2340a5-304b-3030-3438-304757545448","4d2340a5-304b-3030-3936-30475754544b","4d2340a5-304b-3130-3932-30475754544c","4d2340a5-304b-3330-3834-30475754544e"],"type_of_change":"1","version":"HPG6","vib_list":[{"name":"CP048408","version":"HPG6.3-7.0.0.15843807"}]}],"id":{"product":"c5274a8d3e3e40d790c226da85bd84aa","version":"526c2f35074e4106bc2436ed31826a65"},"installation":{"command":"CP040790.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>Additional information to execute VIB file.</strong></p>\n\n<p><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p>             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul>\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p> </p>\n\n<p><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul>\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul>\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VK003840GWTTD","target_guid":"562340a5-304b-3330-3834-304757545444","type":"sata"},{"id":"MK003840GWTTN","target_guid":"4d2340a5-304b-3330-3834-30475754544e","type":"sata"},{"id":"VK001920GWTTC","target_guid":"562340a5-304b-3130-3932-304757545443","type":"sata"},{"id":"MK001920GWTTL","target_guid":"4d2340a5-304b-3130-3932-30475754544c","type":"sata"},{"id":"VK000960GWTTB","target_guid":"562340a5-304b-3030-3936-304757545442","type":"sata"},{"id":"MK000960GWTTK","target_guid":"4d2340a5-304b-3030-3936-30475754544b","type":"sata"},{"id":"VK000480GWTTA","target_guid":"562340a5-304b-3030-3438-304757545441","type":"sata"},{"id":"MK000480GWTTH","target_guid":"4d2340a5-304b-3030-3438-304757545448","type":"sata"},{"id":"VK000240GWTSV","target_guid":"562340a5-304b-3030-3234-304757545356","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T04:55:16","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for ESXi 7.0 U1.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK003840GWTTD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWTTB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWTTA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GWTTC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWTSV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWTTH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK001920GWTTL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWTTK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK003840GWTTN","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"tw","x_late":"HPE 系統狀況應用程式與命令列公用程式 (hp-health) 彙集了應用程式及工具，可讓您監視風扇、電源供應器、溫度感應器及其他管理事件。此外，亦提供一系列命令列公用程式： ProLiant 開機組態公用程式 (hpbootcfg)、ProLiant 管理命令列介面公用程式 (hpasmcli)、ProLiant 整合式管理記錄 (IML) 公用程式 (hplog) 及 UID (藍色) 燈光公用程式 (hpuid)。"},{"lang":"en","x_late":"The HPE System Health Application and Command Line Utilities (hp-health) is collection of applications and tools which enables monitoring of fans, power supplies, temperature sensors, and other management events.  It also provides collection of command-line utilities: the ProLiant  boot  configuration  utility (hpbootcfg), the ProLiant Management Command Line Interface Utility (hpasmcli), the ProLiant Integrated Management Log (IML) Utility (hplog), and the UID (blue) Light Utility (hpuid)."},{"lang":"ko","x_late":"HPE 시스템 상태 응용 프로그램 및 명령줄 유틸리티(hp-health)는 팬, 전원 공급 장치, 온도 센서 및 기타 관리 이벤트를 모니터링하도록 하는 응용 프로그램 및 도구 모음입니다. 또한 다음과 같은 명령줄 유틸리티 모음을 제공합니다. ProLiant 부팅 구성 유틸리티(hpbootcfg), ProLiant 관리 명령줄 인터페이스 유틸리티(hpasmcli), ProLiant 통합 관리 로그(IML) 유틸리티(hplog) 및 UID(블루) 라이트 유틸리티(hpuid)"},{"lang":"cn","x_late":"HPE System Health Application and Command Line Utilities (hp-health) 是一系列应用程序和工具，能够监控风扇、电源、温度传感器和其他管理事件。它还提供了命令行实用程序集： ProLiant 启动配置实用程序 (hpbootcfg)、ProLiant Management Command Line Interface Utility (hpasmcli)、ProLiant Integrated Management Log (IML) Utility (hplog) 和 UID (blue) Light Utility (hpuid)。"},{"lang":"ja","x_late":"HPEシステムヘルスアプリケーションおよびコマンドラインユーティリティ（hp-health）パッケージは、アプリケーション、およびファンの監視、電源、温度センサー、およびその他管理イベントを行うツールを集めたものです。  また、ProLiantブートコンフィギュレーションユーティリティ（hpbootcfg）、ProLiantマネジメントコマンドラインインターフェイスユーティリティ（hpasmcli）、ProLiantインテグレーテッドマネジメントログ（IML）ユーティリティ（hplog）、およびUID（青）ランプユーティリティ（hpuid）を集めたコマンドラインユーティリティも提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[],"files":[{"bytes":"503856","datemodified":"2021-08-25T02:28:22","file_list":["./opt/hp/hp-health","./opt/hp/hp-health/addons","./opt/hp/hp-health/addons/libcpqci64.a","./opt/hp/hp-health/bin","./opt/hp/hp-health/bin/hp-asrd","./opt/hp/hp-health/bin/hpasmlited","./opt/hp/hp-health/bin/hpasmpld","./opt/hp/hp-health/bin/hpasmxld","./opt/hp/hp-health/examples","./opt/hp/hp-health/examples/lite-mgmt","./opt/hp/hp-health/examples/lite-mgmt/COPYING.txt","./opt/hp/hp-health/examples/lite-mgmt/README.txt","./opt/hp/hp-health/examples/lite-mgmt/cma.conf.nosnmp","./opt/hp/hp-health/examples/lite-mgmt/hpsysmon.sh","./opt/hp/hp-health/hp-health.license","./opt/hp/hp-health/hprpm.xpm","./opt/hp/hp-health/sh","./opt/hp/hp-health/sh/hpasmxld_reset.sh","./sbin/hpasmcli","./sbin/hpbootcfg","./sbin/hplog","./sbin/hpuid","./sbin/rchp-health","./usr/lib/systemd/scripts/hp-asrd.sh","./usr/lib/systemd/scripts/hp-health.sh","./usr/lib/systemd/system/hp-asrd.service","./usr/lib/systemd/system/hp-health.service","./usr/lib64/libcpqci64.so","./usr/lib64/libcpqci64.so.3","./usr/lib64/libcpqci64.so.3.0","./usr/lib64/libhpasmintrfc64.so","./usr/lib64/libhpasmintrfc64.so.3","./usr/lib64/libhpasmintrfc64.so.3.0","./usr/lib64/libhpev64.so","./usr/lib64/libhpev64.so.1","./usr/lib64/libhpev64.so.1.0","./usr/share/man/man4/hp-health.4.gz","./usr/share/man/man4/hpasmcli.4.gz","./usr/share/man/man7/hp_mgmt_install.7.gz","./usr/share/man/man8/hp-asrd.8.gz","./usr/share/man/man8/hpbootcfg.8.gz","./usr/share/man/man8/hplog.8.gz","./usr/share/man/man8/hpuid.8.gz","./usr/share/smartupdate/hp-health/component.xml","./var/log/hp-health","./var/spool/compaq","./var/spool/hp-health"],"md5sum":"18750349fcaad033997d781cab961964","name":"hp-health-10.93-307.6.sles12.x86_64.rpm","release":"2021-08-25T02:20:27","revision":"0","sha1sum":"51086a8eb66630b4d4d0655c5681eda35023e640","size":"492KB","target_guids":[],"type_of_change":"0","version":"10.9.3"}],"id":{"product":"b196e6e9412f4744bd940867ff7e2b2a","version":"67621162b3df4b43b1e601c85b0b5f4b"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<P>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</P>\n<P>To install the package type: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;rpm -ivh hp-health-&lt;version&gt;.rpm</P>\n<P>To check whether the package is loaded properly type: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;/etc/init.d/hp-health status</P>\n<P>Additional help is available by typing: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;man hp-health</P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;or</P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;man hp_mgmt_install</P>"},{"lang":"ja","x_late":"<P>システム管理者（root）としてログインし、RPMをご使用のハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</P>\n<P>パッケージをインストールするには、次のようにタイプします。 </P>\n<P>      rpm -ivh hp-health-<version>.rpm</P>\n<P>パッケージが正しくロードされているか、以下をタイプして確認します。 </P>\n<P>      /etc/init.d/hp-health status</P>\n<P>以下のコマンドを実行してヘルプを参照してください。 </P>\n<P>      man hp-health</P>\n<P>            または</P>\n<P>      man hp_mgmt_install</P>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 SUSE LINUX Enterprise Server 12 的 HPE 系統健康狀況應用程式與命令列公用程式"},{"lang":"en","x_late":"HPE System Health Application and Command Line Utilities for SUSE LINUX Enterprise Server 12"},{"lang":"ko","x_late":"SUSE LINUX Enterprise Server 12용 HPE 시스템 상태 응용 프로그램 및 명령줄 유틸리티"},{"lang":"cn","x_late":"用于 SUSE LINUX Enterprise Server 12的HPE System Health 应用和命令行实用程序"},{"lang":"ja","x_late":"HPEシステムヘルスアプリケーションおよびコマンドラインユーティリティ for SUSE LINUX Enterprise Server 12"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"3309","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3307","subdev":"3309","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3306","subdev":"330e","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3307","subdev":"330e","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-10T13:27:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Enhancements included in this release:</p>\n\n<ul>\n\t<li>Support for SUSE Linux Enterprise Server 12&nbsp;Service Pack 5</li>\n</ul>\n","latest_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>When a customer queries the HPE Software Delivery Repository (SDR) site and experiences a failure amsd no longer exhibits a&nbsp;segfault.</li>\n\t<li>hp-heath service will no longer crash in a non&nbsp;secure boot environment.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>TBD</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"J06","value":"HP ProLiant MicroServer Gen8"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"P66","value":"HP ProLiant DL980 G7 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A16","value":"HP ProLiant DL585 G7 Server"},{"key":"I25","value":"HP ProLiant BL680c G7 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 v2 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"A19","value":"HP ProLiant BL465c G7 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"P78","value":"HP ProLiant ML310e Gen8 v2 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"I27","value":"HP ProLiant BL460c G7 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"A24","value":"HP ProLiant SL335s G7 Server"},{"key":"P68","value":"HP ProLiant DL360 G7 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"O41","value":"HP ProLiant MicroServer"},{"key":"A20","value":"HP ProLiant BL685c G7 Server"},{"key":"P67","value":"HP ProLiant DL380 G7 Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"P65","value":"HP ProLiant DL580 G7 Server"}],"sw_keys":[{"name":"hp-health","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800026","languages":[{"lang":"tw","x_late":"軟體 - 管理"},{"lang":"en","x_late":"Software - Management"},{"lang":"ko","x_late":"소프트웨어 - 관리"},{"lang":"ja","x_late":"ソフトウェア - マネジメント"},{"lang":"cn","x_late":"软件 - 管理"}]}],"description":[{"lang":"en","x_late":"The HPE ESXi Agentless Management Smart Component for ESXi 7.0 includes the latest HPE Agentless Management Service (AMS), and AMS ESXCLI Interface."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"600864","datemodified":"2021-09-03T00:47:49","file_list":["/cp047519.xml","/amshelprComponent_701.11.8.0.12-1_18567695.zip","/amshelprComponent_701.11.8.0.12-1_18567695.zip/index.xml","/amshelprComponent_701.11.8.0.12-1_18567695.zip/vendor-index.xml","/amshelprComponent_701.11.8.0.12-1_18567695.zip/metadata.zip","/amshelprComponent_701.11.8.0.12-1_18567695.zip/vib20/amshelpr/HPE_bootbank_amshelpr_701.11.8.0.12-1OEM.701.0.0.16850804.vib","/amshelprComponent_701.11.8.0.12-1_18567695.zip/metadata.zip/vendor-index.xml","/amshelprComponent_701.11.8.0.12-1_18567695.zip/metadata.zip/vmware.xml","/amshelprComponent_701.11.8.0.12-1_18567695.zip/metadata.zip/vibs/amshelpr-3766374327101518381.xml","/amshelprComponent_701.11.8.0.12-1_18567695.zip/metadata.zip/bulletins/amshelprComponent_701.11.8.0.12-1.xml"],"md5sum":"2a0e6dc1415b06324f080e1fe5a91eb2","name":"cp047519.zip","release":"2021-09-03T00:43:43","revision":"0","sha1sum":"c8397728dc3a47174999f499c2c5371e0cb43a3e","size":"586KB","target_guids":[],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"amshelpr","version":"701.11.8.0.12-1OEM.701.0.0.16850804"}]}],"id":{"product":"06046a88182e43b38ad262913cbf0784","version":"bbacedc2332f439382e36e95d38e4c05"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To&nbsp;remotely install&nbsp;this&nbsp;bundle&nbsp; online using the HPE Smart Update Manager (HPSUM) from the HPE Service Pack for ProLiant (SPP):</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\">HPE USB Key Utility</a>.</li>\n\t<li>Copy&nbsp;this driver component&nbsp;to the directory<em> /SPP20xxxxx/hp/swpackages</em> on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.</li>\n\t<li>Change directories to <em>/hp/swpackages</em> and execute&nbsp;./hpsum.</li>\n\t<li>Select the &quot;next&quot; button.</li>\n\t<li>Click &quot;Add Single Target.&quot;</li>\n\t<li>Enter&nbsp;the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow HP Smart Update Manager&nbsp;instructions&nbsp;to complete the driver update.</li>\n</ol>\n\n<p><br />\n<strong>To&nbsp;install this bundle using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the component zip file to extract the driver offline bundle.</li>\n\t<li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li>\n</ol>\n\n<p>Refer to VMware documentation for information on the esxcli commands</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Agentless Management Bundle Smart Component for Gen9 on ESXi 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"600"},"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-10-18T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Agentless Management Service</strong></p>\n\n<ul>\n\t<li>Implemented new vSphere 7.0U1 Daemon interface and is only supported on vSphere 7.0U1 and newer.&nbsp;&nbsp; New &quot;esxcli daemon control&quot; commands are now used to stop/start/restart AMS.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Agentless Management Service</strong></p>\n\n<ul>\n\t<li>Fixed resource leak when AHS logging fails</li>\n\t<li>Fix incorrect reporting of SATA disks attached to Smart Array and SAS controllers in the cpqIdeAtaDisk MIB</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Agentless Management Service</strong></p>\n\n<ul>\n\t<li>Applied fixes to net-snmp open source code for CVE-2018-18065, CVE-2018-18066, CVE-2015-5621</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"}],"sw_keys":[{"name":"amshelpr:701.11.8.0.12-1OEM.701.0.0.16850804","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000JFEML","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a46454d4c","Version":"HPD6"},{"DeviceName":"MB4000JFEMN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a46454d4e","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SAS drive models: MB2000JFEML and MB4000JFEMN"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSASドライブモデルのファームウェアを提供します。MB2000JFEMLおよびMB4000JFEMN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB2000JFEML and MB4000JFEMN Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><br />\n<strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.&nbsp; This issue was found during supplier ongoing reliability testing.</p>\n\t</li>\n\t<li>\n\t<p>The firmware also includes emergency power off improvements.</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5505846","datemodified":"2021-07-23T07:16:12","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-624b75c7e2-HPD6-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-624b75c7e2-HPD6-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-624b75c7e2-HPD6-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-624b75c7e2-HPD6-8.1/CP048159.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-624b75c7e2-HPD6-8.1/HAKPNSD6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-624b75c7e2-HPD6-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-624b75c7e2-HPD6-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-624b75c7e2-HPD6-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-624b75c7e2-HPD6-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048159.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048159.scexe"],"md5sum":"857760407781b70b7a45bb399317e2a1","name":"firmware-hdd-624b75c7e2-HPD6-8.1.x86_64.rpm","release":"2021-07-23T07:02:14","revision":"0","sha1sum":"1a195b480ede4685c5d879f21ae59a27d740670f","size":"5MB","target_guids":["002340a5-4d00-3242-3030-304a46454d4c","002340a5-4d00-3442-3030-304a46454d4e"],"type_of_change":"2","version":"HPD6"}],"id":{"product":"e3c28d7e84d2418a888d50f48b760538","version":"55e1712e6d9b45b9add89108fb0afa52"},"installation":{"command":"CP040328.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB2000JFEML and MB4000JFEMN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB2000JFEMLおよびMB4000JFEMNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"MB2000JFEML","target_guid":"002340a5-4d00-3242-3030-304a46454d4c","type":"sas"},{"id":"MB4000JFEMN","target_guid":"002340a5-4d00-3442-3030-304a46454d4e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T15:33:04","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was found during supplier ongoing reliability testing.</li>\n\t<li>The firmware also includes emergency power off improvements.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was found during supplier ongoing reliability testing.</li>\n\t<li>The firmware also includes emergency power off improvements.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JFEMN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB2000JFEML","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for the HPE Blade Emulex 10/20GbE Server Adapters for Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージは、HPE Blade Emulex 10/20GbEサーバーアダプタードライバー for Windows Server 2019が含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1607136","datemodified":"2021-08-16T16:55:26","file_list":["bepnic.dll","bepnic.rtf","cp045174.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll","occfg.exe","ocnd65.cat","ocnd65.inf","ocnd65.sys"],"md5sum":"3093635d99a9219ff96c5c26511b7fdc","name":"cp045174.exe","release":"2021-08-16T16:41:07","revision":"0","sha1sum":"09decd257803e4a2c1a3c734597b9778e11838bd","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfe4a13f6"],"type_of_change":"0","version":"12.0.1344.0"}],"id":{"product":"a696c5bfe8e646f9a237f7c9cfde41c1","version":"c1c8e6f9919440fbbf75f9b326be855e"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE Driver for Windows Server 2019"},{"lang":"ja","x_late":"HPE Blade Emulex 10/20GbEドライバーfor Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"0728","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c1935","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c1934","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-03T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports the&nbsp;HPE ProLiant BL660c Gen9 Server.&nbsp;</p>\n","curr_fixes_x_late":"<p>This driver addresses a Windows Stop Error (BSOD) seen after Windows Event ID 67.<br />\nThis driver corrects an issue which results in a BSOD for Software Defined Data Center (SDDC).</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"ocnd65.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Blade Intel ixgbe Ethernet NICs running under Red Hat Enterprise Linux 7."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7で動作するHPE Blade Intel ixgbe Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"201476","datemodified":"2021-03-08T18:14:57","file_list":["./etc/depmod.d/hp-ixgbe.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/hp-ixgbe","./lib/modules/3.10.0-1127.el7.x86_64/extra/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/kmod-hp-ixgbe_bl/component.xml"],"md5sum":"cb1dc8d6f457f65d09afda610476c154","name":"kmod-hp-ixgbe_bl-5.9.4-1.rhel7u8.x86_64.rpm","release":"2021-03-08T18:02:06","revision":"0","sha1sum":"1d57731b73fb757dec2755ec6c7e2bc79ea3f5c2","size":"196KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec05844b56"],"type_of_change":"0","version":"5.9.4-1"},{"bytes":"201471","datemodified":"2021-03-08T18:10:44","file_list":["./etc/depmod.d/hp-ixgbe.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/hp-ixgbe","./lib/modules/3.10.0-1160.el7.x86_64/extra/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/kmod-hp-ixgbe_bl/component.xml"],"md5sum":"06f793669170fc58805b782b3bb411e7","name":"kmod-hp-ixgbe_bl-5.9.4-1.rhel7u9.x86_64.rpm","release":"2021-03-08T18:02:06","revision":"0","sha1sum":"7a89299f595cdd2e3fe23b30825d3723930b0a7c","size":"196KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec05844b56"],"type_of_change":"0","version":"5.9.4-1"}],"id":{"product":"571bc8d279024498916baff035cbe35c","version":"06be4bb694964643a6b2119ad4e67d30"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Intel ixgbe Drivers for Red Hat Enterprise Linux 7"},{"lang":"ja","x_late":"HPE Blade Intel ixgbeドライバー for Red Hat Enterprise Linux 7"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c18d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>These drivers have been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 7, Updates 8 and 9.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"kmod-hp-ixgbe_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbe_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbe_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbe_bl","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Blade Intel ixgben Adapters running under VMware vSphere 7.0."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;1.8.9.0.</p>\n"}],"files":[{"bytes":"284001","datemodified":"2020-04-22T11:42:06","file_list":["/cp041435.xml","/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895-package.zip","/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895-package.zip/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895.zip","/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895-package.zip/doc/README.txt","/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895-package.zip/doc/release_note_ixgben_1.8.9.0-1OEM.700.1.0.15525992.pdf","/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895-package.zip/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895.zip/index.xml","/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895-package.zip/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895.zip/vendor-index.xml","/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895-package.zip/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895.zip/metadata.zip","/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895-package.zip/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895.zip/vib20/ixgben/INT_bootbank_ixgben_1.8.9.0-1OEM.700.1.0.15525992.vib","/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895-package.zip/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895.zip/metadata.zip/vendor-index.xml","/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895-package.zip/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895.zip/metadata.zip/vmware.xml","/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895-package.zip/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895.zip/metadata.zip/vibs/ixgben-6835652811471104199.xml","/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895-package.zip/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895.zip/metadata.zip/bulletins/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992.xml"],"md5sum":"2f757e3cbfd81998bb33d05bb86f3adf","name":"cp041435.zip","release":"2020-04-22T16:41:22","revision":"0","sha1sum":"2e39cedcd48b05250082c3929aad3d47b9daef0b","size":"277KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4a9c3d5c","20a6e8e4-bf33-4c71-a6bf-d9ec6164afab"],"type_of_change":"0","version":"2020.06.01","vib_list":[{"name":"ixgben","version":"1.8.9.0-1OEM.700.1.0.15525992"}]}],"id":{"product":"026326f2a6e64525ac6b82dd92bae1e8","version":"a4dec67fa9664a5b9252cb1863340f4b"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Intel ixgben Driver for VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c18d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-05-27T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"ixgben:1.8.9.0-1OEM.700.1.0.15525992","sw_key_expectedpath":"driver:vmware:zip"},{"name":"Intel-ixgben:1.8.9.0-1OEM.700.1.0.15525992","sw_key_expectedpath":"driver.component:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6046625","datemodified":"2021-05-18T04:13:15","file_list":["./usr/lib/i386-linux-gnu/firmware-system-u19-2.90_2021_04_29-1.1","./usr/lib/i386-linux-gnu/firmware-system-u19-2.90_2021_04_29-1.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-system-u19-2.90_2021_04_29-1.1/.setup","./usr/lib/i386-linux-gnu/firmware-system-u19-2.90_2021_04_29-1.1/CP047853.xml","./usr/lib/i386-linux-gnu/firmware-system-u19-2.90_2021_04_29-1.1/U19_2.90_04_29_2021.signed.flash","./usr/lib/i386-linux-gnu/firmware-system-u19-2.90_2021_04_29-1.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-system-u19-2.90_2021_04_29-1.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP047853.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP047853.scexe"],"md5sum":"baf8158dd67232aeb0524562efcf86ab","name":"firmware-system-u19-2.90_2021_04_29-1.1.i386.rpm","release":"2021-05-18T04:03:19","revision":"0","sha1sum":"97db067808e521261bf958506d7da862ad354bd1","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021"}],"id":{"product":"6243eef4eb164aedb3860ce40f4d445d","version":"8455285732ad436191e731404da12524"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HPE ProLiant Agentless Management Service (<strong>AMS</strong>) and HPE SNMP Agents (<strong>SNMP Agents</strong>) are both running.&nbsp; HPE does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager 8.0.0 or later, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、iLOとの通信ができない場合に失敗します。  これは、HPE ProLiant Agentless Management Service (<strong>AMS</strong>)およびHPE SNMPエージェント(<strong>SNMP Agents</strong>)の両方が実行されているときに発生します。  HPEでは、AMSおよびSNMPエージェントを同時に実行させないことを推奨します。  「iLO device not found」エラーが発生した場合、AMSまたはSNMPエージェントを停止させて、再度フラッシュコンポーネントを実行します。<br />\n<br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上のSmart Update Manager 8.0.0以降を使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE Apollo 4200 Gen9/HPE ProLiant XL420 Gen9 (U19) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Linux - HPE Apollo 4200 Gen9/HPE ProLiant XL420 Gen9 (U19) サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Oracle Linux 6 (AMD64/EMT64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Oracle Linux 7","platform":"Oracle Enterprise Linux","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-05T03:52:39","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","latest_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390.  These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U19","value":"HPE ProLiant XL420 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"}],"sw_keys":[{"name":"U19","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO002000KWVVC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3230-3030-304b57565643","Version":"4ICRHPK3"},{"DeviceName":"VO004000KWVUR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3430-3030-304b57565552","Version":"4ICRHPK3"},{"DeviceName":"MO001600KWVUU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b57565555","Version":"4ICRHPK3"},{"DeviceName":"MO003200KWVUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b57565556","Version":"4ICRHPK3"},{"DeviceName":"MO006400KWVVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b57565641","Version":"4ICRHPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Linux (x64) - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp;&nbsp; 4ICRHPK3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp; &nbsp;&nbsp; </strong>None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>The issue affects SSDs with an HPE firmware version prior to 4ICRHPK3 that may result in SSD failure starting at 4,700 hours of operation, neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us\" style=\"color: blue; text-decoration: underline;\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us</a></li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong>&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"5101549","datemodified":"2021-07-23T08:44:07","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-3.1/4ICRHPK3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-3.1/CP048231.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048231.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048231.scexe"],"md5sum":"74d211e3eec17f36654c7dfea7a56cb3","name":"firmware-hdd-92d876cfea-4ICRHPK3-3.1.x86_64.rpm","release":"2021-07-23T08:31:04","revision":"0","sha1sum":"dd86b0b4f46b89f7842ea045841376b58a3ec314","size":"4MB","target_guids":["562340a5-304f-3230-3030-304b57565643","562340a5-304f-3430-3030-304b57565552","4d2340a5-304f-3130-3630-304b57565555","4d2340a5-304f-3330-3230-304b57565556","4d2340a5-304f-3630-3430-304b57565641"],"type_of_change":"2","version":"4ICRHPK3"}],"id":{"product":"8adb99f8960b4849ba6664217211b8d2","version":"925d00301ad6475bacbe548bc7ba4fef"},"installation":{"command":"CP043037.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p><strong>Additional Information:</strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p><strong>追加情報:</strong></p>\n\n<p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - VO002000KWVVC、VO004000KWVUR、MO001600KWVUU、MO003200KWVUV、およびMO006400KWVVAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VO002000KWVVC","target_guid":"562340a5-304f-3230-3030-304b57565643","type":"nvme"},{"id":"VO004000KWVUR","target_guid":"562340a5-304f-3430-3030-304b57565552","type":"nvme"},{"id":"MO001600KWVUU","target_guid":"4d2340a5-304f-3130-3630-304b57565555","type":"nvme"},{"id":"MO003200KWVUV","target_guid":"4d2340a5-304f-3330-3230-304b57565556","type":"nvme"},{"id":"MO006400KWVVA","target_guid":"4d2340a5-304f-3630-3430-304b57565641","type":"nvme"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-01T05:58:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>\n\t<p>Added support for Intel VROC platform.</p>\n\t</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to 4ICRHPK3 that may result in SSD failure starting at 4,700 hours of operation, neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us\" style=\"color: blue; text-decoration: underline;\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us</a></li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to 4ICRHPK3 that may result in SSD failure starting at 4,700 hours of operation, neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us\" style=\"color: blue; text-decoration: underline;\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MO001600KWVUU","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO002000KWVVC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO004000KWVUR","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO006400KWVVA","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO003200KWVUV","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000JEQNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPSCDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a45514e4c","Version":"HPDB"},{"DeviceName":"MB6000JEQNN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPSCDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a45514e4e","Version":"HPDB"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB4000JEQNL and MB6000JEQNN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB4000JEQNL and MB6000JEQNN Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPDB<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3669728","datemodified":"2021-07-25T14:55:06","file_list":["cp048608.xml","cpqsetup.exe","HAKPSCDB.rel","payload.json","setup.dll"],"md5sum":"bd52723a1d512feb0ff51e7d81b3cb0c","name":"cp048608.exe","release":"2021-07-25T14:48:05","revision":"0","sha1sum":"50c65aaf9ef7d36c7c8fdd6c5d3abd322b8a5258","size":"3MB","target_guids":["002340a5-4d00-3442-3030-304a45514e4c","002340a5-4d00-3642-3030-304a45514e4e"],"type_of_change":"1","version":"HPDB"}],"id":{"product":"b2d8d2ad18164775b6ab15fb40652791","version":"fd3e6a31e9af4032ae4b205a7e0937e9"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB4000JEQNL and MB6000JEQNN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB4000JEQNLおよびMB6000JEQNNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB4000JEQNL","target_guid":"002340a5-4d00-3442-3030-304a45514e4c","type":"sas"},{"id":"MB6000JEQNN","target_guid":"002340a5-4d00-3642-3030-304a45514e4e","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T11:07:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JEQNL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB6000JEQNN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GWTFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG07abHPG7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304757544645","Version":"HPG7"},{"DeviceName":"MB014000GWTFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG07abHPG7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304757544646","Version":"HPG7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB012000GWTFE and MB014000GWTFF"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB012000GWTFEおよびMB014000GWTFF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MB012000GWTFE and MB014000GWTFF Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG7</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG6</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG6<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp; &nbsp;&nbsp; None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp; </strong>&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"3050144","datemodified":"2021-07-23T11:15:10","file_list":["cp048543.xml","cpqsetup.exe","payload.json","setup.dll","TAMG07abHPG7.REL"],"md5sum":"c6fa420d5b0f1546f51f8ea61b10f1da","name":"cp048543.exe","release":"2021-07-23T11:07:05","revision":"0","sha1sum":"09db85de60a67b348e916e0b0505ea8cce3a8174","size":"2MB","target_guids":["4d2340a5-3042-3231-3030-304757544645","4d2340a5-3042-3431-3030-304757544646"],"type_of_change":"1","version":"HPG7"}],"id":{"product":"3b83490f55194800be58721a957dd6a1","version":"b60b237fb24641f4bc904d405304dd1c"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB012000GWTFE and MB014000GWTFF Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows(x64)- MB012000GWTFEおよびMB014000GWTFFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB014000GWTFF","target_guid":"4d2340a5-3042-3431-3030-304757544646","type":"sata"},{"id":"MB012000GWTFE","target_guid":"4d2340a5-3042-3231-3030-304757544645","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T11:17:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB012000GWTFE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB014000GWTFF","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH0300JEDHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SVKBPND4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3330-304a45444843","Version":"HPD4"},{"DeviceName":"EH0450JEDHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SVKBPND4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3435-304a45444844","Version":"HPD4"},{"DeviceName":"EH0600JEDHE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SVKBPND4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3630-304a45444845","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EH0300JEDHC, EH0450JEDHD and EH0600JEDHE"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EH0300JEDHC、EH0450JEDHDおよびEH0600JEDHE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EH0300JEDHC, EH0450JEDHD&nbsp;and EH0600JEDHE Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"17267960","datemodified":"2021-08-30T07:15:55","file_list":["/CP048293_BUILD_2.data","/CP048293.vmexe","/CP048293.vmexe64","/CP048293.vmfile","/CP048293_VMw.zip","/CP048293.xml","/payload.json","/CP048293_VMw.zip/index.xml","/CP048293_VMw.zip/vendor-index.xml","/CP048293_VMw.zip/metadata.zip","/CP048293_VMw.zip/vib20/CP048293/HPE_bootbank_CP048293_HPD4.2-7.0.0.15843807.vib","/CP048293_VMw.zip/metadata.zip/vendor-index.xml","/CP048293_VMw.zip/metadata.zip/vmware.xml","/CP048293_VMw.zip/metadata.zip/vibs/CP048293-4570890945673392922.xml","/CP048293_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048293_HPD4.2-7.0.0.15843807.xml"],"md5sum":"24bf4770951e00774d0d14919ca4c975","name":"CP048293.zip","release":"2021-08-30T07:11:18","revision":"0","sha1sum":"5507357e4dbe57f95f428b9833c492b3f483f583","size":"16MB","target_guids":["002340a5-4500-3048-3330-304a45444843","002340a5-4500-3048-3435-304a45444844","002340a5-4500-3048-3630-304a45444845"],"type_of_change":"1","version":"HPD4","vib_list":[{"name":"CP048293","version":"HPD4.2-7.0.0.15843807"}]}],"id":{"product":"10fb5093c8b24e83a8541c8c40bc7e15","version":"e8f15d57622d4e59bc754896a76d9d14"},"installation":{"command":"CP039423.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EH0300JEDHC, EH0450JEDHD and EH0600JEDHE Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EH0300JEDHC、EH0450JEDHD、およびEH0600JEDHEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EH0300JEDHC","target_guid":"002340a5-4500-3048-3330-304a45444843","type":"sas"},{"id":"EH0450JEDHD","target_guid":"002340a5-4500-3048-3435-304a45444844","type":"sas"},{"id":"EH0600JEDHE","target_guid":"002340a5-4500-3048-3630-304a45444845","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-03T08:18:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH0600JEDHE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0300JEDHC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0450JEDHD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Broadcom Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Broadcom NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"112622","datemodified":"2021-01-17T07:15:49","file_list":["./lib/modules/4.12.14-195-default","./lib/modules/4.12.14-195-default/updates","./lib/modules/4.12.14-195-default/updates/tg3.ko","./usr/share/smartupdate/tg3-kmp-default/component.xml"],"md5sum":"3540fae140010c29bdfdc10671bb0682","name":"tg3-kmp-default-3.139b_k4.12.14_195-2.sles15sp1.x86_64.rpm","release":"2021-01-17T07:08:05","revision":"0","sha1sum":"bf2d54d7cf5a7c7cc82dd11c54d88d7276b00e03","size":"109KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a"],"type_of_change":"0","version":"3.139b-2"},{"bytes":"112984","datemodified":"2021-01-17T07:13:10","file_list":["./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/tg3.ko","./usr/share/smartupdate/tg3-kmp-default/component.xml"],"md5sum":"c88102ebdfd665af2905f709fdbb3bcf","name":"tg3-kmp-default-3.139b_k5.3.18_22-2.sles15sp2.x86_64.rpm","release":"2021-01-17T07:08:05","revision":"0","sha1sum":"329b24b50b825c9b6c5bb24d3a5e52c36121a1d9","size":"110KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a"],"type_of_change":"0","version":"3.139b-2"}],"id":{"product":"8e8482d9e6e6494a8e54ec40143d190a","version":"8b3861aed8424b6ba84825a2bb5c6d1f"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation instructions.</p>\n"},{"lang":"ja","x_late":"<p>インストール手順についてのREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Broadcom tg3 Ethernet Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE Broadcom tg3 Ethernetドライバー for SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"165F","subdev":"22E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c22e8","type":"pci","ven":"14E4"},{"dev":"1665","subdev":"22BD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1665103c22bd","type":"pci","ven":"14E4"},{"dev":"165F","subdev":"1786","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c1786","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"169D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c169d","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"3383","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c3383","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"22BE","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c22be","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports sles15 sp1</p>\n","latest_fixes_x_late":"<p>This product fixes an issue where the SLES15 driver be selected by HPSUM deployment for SLES15sp1 OS<br />\nThis product now exports vendor and packager tag in RPM metadata<br />\nThis product addresses the issue where the SLES15 component always be selected by HPSUM deployment</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports Suse Linux Enterprise Server 15 Service Pack 2</p>\n","curr_fixes_x_late":"<p>The products fixes an a race condition issue where driver will still try to access the PHY(physical layer) although it was already brought down when the tg3 timer fires</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"tg3-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"tg3-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"tg3-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"tg3-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWZJF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304a575a4a46","Version":"HPD4"},{"DeviceName":"VO001920JWZJH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304a575a4a48","Version":"HPD4"},{"DeviceName":"VO003840JWZJK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304a575a4a4b","Version":"HPD4"},{"DeviceName":"VO007680JWZJL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304a575a4a4c","Version":"HPD4"},{"DeviceName":"VO015360JWZJN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3336-304a575a4a4e","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"16577408","datemodified":"2021-08-27T13:47:25","file_list":["/CP048455_BUILD_2.data","/CP048455.vmexe","/CP048455.vmexe64","/CP048455.vmfile","/CP048455_VMw.zip","/CP048455.xml","/payload.json","/CP048455_VMw.zip/index.xml","/CP048455_VMw.zip/vendor-index.xml","/CP048455_VMw.zip/metadata.zip","/CP048455_VMw.zip/vib20/CP048455/HPE_bootbank_CP048455_HPD4.2-7.0.0.15843807.vib","/CP048455_VMw.zip/metadata.zip/vendor-index.xml","/CP048455_VMw.zip/metadata.zip/vmware.xml","/CP048455_VMw.zip/metadata.zip/vibs/CP048455-1749296248874906850.xml","/CP048455_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048455_HPD4.2-7.0.0.15843807.xml"],"md5sum":"6492b6e7df5cc02d7db812e63f96e2be","name":"CP048455.zip","release":"2021-08-27T13:42:55","revision":"0","sha1sum":"74dd4380857cbf20fcb9317f9cc90d03f18b0e57","size":"15MB","target_guids":["562340a5-304f-3030-3936-304a575a4a46","562340a5-304f-3130-3932-304a575a4a48","562340a5-304f-3330-3834-304a575a4a4b","562340a5-304f-3730-3638-304a575a4a4c","562340a5-304f-3531-3336-304a575a4a4e"],"type_of_change":"1","version":"HPD4","vib_list":[{"name":"CP048455","version":"HPD4.2-7.0.0.15843807"}]}],"id":{"product":"0b3bbfed90454334ba3331c2f9efa2ea","version":"d9623e2c915e494594436e6c885a4931"},"installation":{"command":"CP043253.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VO000960JWZJF、VO001920JWZJH、VO003840JWZJK、 VO007680JWZJLおよびVO015360JWZJNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VO015360JWZJN","target_guid":"562340a5-304f-3531-3336-304a575a4a4e","type":"sas"},{"id":"VO007680JWZJL","target_guid":"562340a5-304f-3730-3638-304a575a4a4c","type":"sas"},{"id":"VO003840JWZJK","target_guid":"562340a5-304f-3330-3834-304a575a4a4b","type":"sas"},{"id":"VO001920JWZJH","target_guid":"562340a5-304f-3130-3932-304a575a4a48","type":"sas"},{"id":"VO000960JWZJF","target_guid":"562340a5-304f-3030-3936-304a575a4a46","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T08:02:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Modify Drive Vendor Identification String (VID) in Inquiry page from &ldquo;HP&rdquo; to &ldquo;HPE&rdquo;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO015360JWZJN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO007680JWZJL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920JWZJH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000960JWZJF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003840JWZJK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800214","languages":[{"lang":"fr","x_late":"Logiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Software - Storage Controller"},{"lang":"cn","x_late":"软件 - 存储控制器"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Software - Speichercontroller"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Software - Controller di memorizzazione"},{"lang":"ja","x_late":"ソフトウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Software - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"The HPE Smart Array SAS/SATA Event Notification Service provides event notification to the 64-bit Microsoft Windows Server 2012, 2012 R2, 2016, and 2019 editions system event log and the HPE ProLiant Integrated Management Log for systems using the HPE Smart Array SAS/SATA controller driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[],"files":[{"bytes":"663152","datemodified":"2018-09-12T01:13:28","file_list":["cissesrv.dll","cissesrv.exe","cissesrv.msi","cp037465.xml","cpqsetup.exe"],"md5sum":"bf339ceb1536ea7a248fceb54892dd0e","name":"cp037465.exe","release":"2018-09-12T06:12:04","revision":"0","sha1sum":"647f57a28fcfa7a547bb039566ed4fdc07ff6c3a","size":"647KB","target_guids":[],"type_of_change":"0","version":"6.46.0.64"}],"id":{"product":"C9019","version":"e52301c0ca104cbb9bbb531d56bc60b3"},"installation":{"command":"cpqsetup.exe","command_params":"/verbose_log","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Smart Array SAS/SATA Controller Driver","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b896bf","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Smart Array SAS/SATA Controller Driver"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Smart Array HPCISSS3 Controller Driver for Windows Server","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfd368f11","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Smart Array HPCISSS3 Controller Driver for Windows Server"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Embedded G6 SATA RAID Controller Driver for Microsoft Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfe76aead","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Embedded G6 SATA RAID Controller Driver for Microsoft Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Dynamic Smart Array RAID Controller Driver for Windows Server","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5165615f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Dynamic Smart Array RAID Controller Driver for Windows Server"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Dynamic Smart Array RAID Controller Driver for Windows Server","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec98fcf239","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Dynamic Smart Array RAID Controller Driver for Windows Server"}]}]}]},"installation_notes":[{"lang":"tw","x_late":"將智慧型元件下載至硬碟上的目錄，並變更至該目錄。下載的檔案為自我解壓縮的可執行檔，其檔名包含智慧型元件編號。<br><p>從該磁碟和目錄，執行下載的檔案。"},{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file."},{"lang":"ko","x_late":"스마트 구성 요소를 하드 드라이브의 디렉터리로 다운로드하고 그 디렉터리로 이동합니다. 다운로드한 파일은 스마트 구성 요소 번호에 따라 파일 이름이 지정된 자동 압축 풀기 실행 파일입니다.<br><p>드라이브와 디렉터리에서 다운로드한 파일을 실행합니다."},{"lang":"cn","x_late":"将智能组件下载到硬盘目录中，然后转至该目录。下载的文件是一个自解压可执行文件，其文件名基于 Smart Component 编号命名。<br><p>在该硬盘目录中，执行下载的文件。"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスク ドライブにダウンロードし、そのディレクトリに移動します。 ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE ProLiant Smart Array SAS/SATA Event Notification Service for 64-bit Windows Server Editions"},{"lang":"ja","x_late":"64-bit Windows Server Editions用HPE ProLiant Smartアレイ SAS/SATA Event Notification Service"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"3233","subdev":"3233","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"8D06","subdev":"009C","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"8D66","subdev":"009D","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"193F","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"A106","subdev":"00C0","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"A107","subdev":"00C0","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"3239","subdev":"21BD","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ca","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c2","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c0","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c3","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21be","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cb","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c1","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c5","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21CD","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cc","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c7","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21bf","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c8","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c6","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ce","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-09-27T07:12:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support for Microsoft Windows 10</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added support for Windows Server 2019 OS.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"}],"sw_keys":[{"name":"cissesrv.exe","sw_key_expectedpath":"%programfiles%\\hp\\cissesrv"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO001600KWZQP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173500HPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b575a5150","Version":"HPK5"},{"DeviceName":"MO003200KWZQQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173500HPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b575a5151","Version":"HPK5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MO001600KWZQP and MO003200KWZQQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;NVMe SSD&nbsp;Flash Component for Linux (x64) - MO001600KWZQP and MO003200KWZQQ Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n"}],"files":[{"bytes":"9399117","datemodified":"2021-07-25T12:32:01","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-95b6ae2e85-HPK5-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-95b6ae2e85-HPK5-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-95b6ae2e85-HPK5-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-95b6ae2e85-HPK5-4.1/CP048237.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-95b6ae2e85-HPK5-4.1/GP173500HPK5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-95b6ae2e85-HPK5-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-95b6ae2e85-HPK5-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-95b6ae2e85-HPK5-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-95b6ae2e85-HPK5-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048237.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048237.scexe"],"md5sum":"3ecc95fc9b42ab3cc8002b9825d3e790","name":"firmware-hdd-95b6ae2e85-HPK5-4.1.x86_64.rpm","release":"2021-07-25T12:19:04","revision":"0","sha1sum":"581e5d863c987c7c514fa9165f666ff2f833d919","size":"8MB","target_guids":["4d2340a5-304f-3130-3630-304b575a5150","4d2340a5-304f-3330-3230-304b575a5151"],"type_of_change":"2","version":"HPK5"}],"id":{"product":"5cda8f412fa0418489dbcbbf3f49c1b5","version":"7a8cc9a96dbb49588e8c8e4b0e20c09f"},"installation":{"command":"CP041864.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left: 30pt;\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left: 30pt;\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - MO001600KWZQP and MO003200KWZQQ Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - MO001600KWZQPおよびMO003200KWZQQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MO003200KWZQQ","target_guid":"4d2340a5-304f-3330-3230-304b575a5151","type":"nvme"},{"id":"MO001600KWZQP","target_guid":"4d2340a5-304f-3130-3630-304b575a5150","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-01T07:40:30","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MO003200KWZQQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO001600KWZQP","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GWSSC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757535343","Version":"HPG3"},{"DeviceName":"MK000960GWSSD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757535344","Version":"HPG3"},{"DeviceName":"MK001920GWSSE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304757535345","Version":"HPG3"},{"DeviceName":"MK003840GWSSF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-304757535346","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MK000480GWSSC, MK000960GWSSD, MK001920GWSSE and MK003840GWSSF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MK000480GWSSC, MK000960GWSSD, MK001920GWSSE and MK003840GWSSF Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG2</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG2<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fix</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"19075094","datemodified":"2021-08-27T12:10:49","file_list":["/CP048432_BUILD_2.data","/CP048432.vmexe","/CP048432.vmexe64","/CP048432.vmfile","/CP048432_VMw.zip","/CP048432.xml","/payload.json","/CP048432_VMw.zip/index.xml","/CP048432_VMw.zip/vendor-index.xml","/CP048432_VMw.zip/metadata.zip","/CP048432_VMw.zip/vib20/CP048432/HPE_bootbank_CP048432_HPG3.2-7.0.0.15843807.vib","/CP048432_VMw.zip/metadata.zip/vendor-index.xml","/CP048432_VMw.zip/metadata.zip/vmware.xml","/CP048432_VMw.zip/metadata.zip/vibs/CP048432-8039686905645691817.xml","/CP048432_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048432_HPG3.2-7.0.0.15843807.xml"],"md5sum":"6b414b59c23ea62824b066f7de630a23","name":"CP048432.zip","release":"2021-08-27T12:05:40","revision":"0","sha1sum":"bcea0f3528c29cbc7c0946b2bfe5d441a27b22d6","size":"18MB","target_guids":["4d2340a5-304b-3030-3438-304757535343","4d2340a5-304b-3030-3936-304757535344","4d2340a5-304b-3130-3932-304757535345","4d2340a5-304b-3330-3834-304757535346"],"type_of_change":"1","version":"HPG3","vib_list":[{"name":"CP048432","version":"HPG3.2-7.0.0.15843807"}]}],"id":{"product":"4025ccc149b544568897af8cffe102f9","version":"48b30da6303f4a8888532d316cd63180"},"installation":{"command":"CP041677.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします。</li>\n\t<li>CPXXXXXX.vmexe(ESXi 6.7 &以前のバージョン)およびCPXXXXXX.vmexe64(ESXi 7.0)は、次のコマンドを使用して実行可能です:</li>\n</ul>\n\n<p>             chmod x CPXXXXXX.vmexe    または    chmod x CPXXXXXX.vmexe64</p>\n\n<ul>\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPXXXXXX.vmexe(または)./CPXXXXXX.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MK000480GWSSC, MK000960GWSSD, MK001920GWSSE and MK003840GWSSF Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MK000480GWSSC、MK000960GWSSD、MK001920GWSSE、およびMK003840GWSSFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MK003840GWSSF","target_guid":"4d2340a5-304b-3330-3834-304757535346","type":"sata"},{"id":"MK001920GWSSE","target_guid":"4d2340a5-304b-3130-3932-304757535345","type":"sata"},{"id":"MK000960GWSSD","target_guid":"4d2340a5-304b-3030-3936-304757535344","type":"sata"},{"id":"MK000480GWSSC","target_guid":"4d2340a5-304b-3030-3438-304757535343","type":"sata"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-10T09:28:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK001920GWSSE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWSSC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWSSD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK003840GWSSF","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG1800JEHMD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFL4CD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3830-304a45484d44","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: EG1800JEHMD"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。 EG1800JEHMD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG1800JEHMD Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None&nbsp;</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None.</p>\n"}],"files":[{"bytes":"17488101","datemodified":"2021-08-30T05:36:02","file_list":["/CP048265_BUILD_2.data","/CP048265.vmexe","/CP048265.vmexe64","/CP048265.vmfile","/CP048265_VMw.zip","/CP048265.xml","/payload.json","/CP048265_VMw.zip/index.xml","/CP048265_VMw.zip/vendor-index.xml","/CP048265_VMw.zip/metadata.zip","/CP048265_VMw.zip/vib20/CP048265/HPE_bootbank_CP048265_HPD6.2-7.0.0.15843807.vib","/CP048265_VMw.zip/metadata.zip/vendor-index.xml","/CP048265_VMw.zip/metadata.zip/vmware.xml","/CP048265_VMw.zip/metadata.zip/vibs/CP048265--8153221444251177629.xml","/CP048265_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048265_HPD6.2-7.0.0.15843807.xml"],"md5sum":"d4e9fc156e029a957fad55e0a6bfd1d4","name":"CP048265.zip","release":"2021-08-30T05:31:38","revision":"0","sha1sum":"90ddb569ebb9a66eeb3bf237bc0ea311a9a466cb","size":"16MB","target_guids":["002340a5-4500-3147-3830-304a45484d44"],"type_of_change":"1","version":"HPD6","vib_list":[{"name":"CP048265","version":"HPD6.2-7.0.0.15843807"}]}],"id":{"product":"4d6b330d7f1d4462bea2b4b6ff4f5e4a","version":"a5425ea17fb043f6a196aaa90090983d"},"installation":{"command":"CP040624.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EG1800JEHMD Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EG1800JEHMDドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG1800JEHMD","target_guid":"002340a5-4500-3147-3830-304a45484d44","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-02T11:52:13","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG1800JEHMD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component updates the firmware on ProLiant Gen9 NVMe storage backplanes."},{"lang":"ja","x_late":"このコンポーネントは、ProLiant Gen9 NVMe ストレージバックプレーンのファームウェアをアップデートします。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"539776","datemodified":"2018-10-02T23:19:46","file_list":["cp037743.xml","cpqsetup.exe","cpqsysio64.sys","NVMe_BP_flashV8B4_signed.hex","SignedImageInstaller64.dll"],"md5sum":"244576e349e2d5fe1e0a57d00a25cb56","name":"cp037743.exe","release":"2018-10-03T04:19:03","revision":"0","sha1sum":"379198028e2db0041b12f2662376e86cadf36f46","size":"527KB","target_guids":[],"type_of_change":"0","version":"8.4"}],"id":{"product":"eb945575db8f48b5a4d14fa2a05d3f58","version":"4368d6a7a48c448c8f9f6e94a7795a41"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type: square;\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the&nbsp;</strong><strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a><strong>:</strong></strong></p>\n\n<ul style=\"list-style-type: square;\">\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li>\n\t<li>Run launch_sum.bat script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type: square;\">\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには </strong><strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant </a><strong></strong></strong>から以下の手順に従ってください:</p>\n\n<ul style=\"list-style-type: square;\">\n\t<li>ディレクトリ\\SPP20xxxxx\\hp\\swpackagesにアップデートに必要なファームウェアをコピーします。</li>\n\t<li>ISOのルートにある launch_hpsum.sh スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Flash Component for Windows x64 - NVMe Backplane PIC Firmware"},{"lang":"ja","x_late":"オンラインフラッシュコンポーネント for Windows x64 - NVMeバックプレーンPICファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"id":"NVMe Backplane","target_guid":"","type":"pic"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2018-10-29T17:41:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Resolved an information disclosure vulnerability issue; ref: CVE-2017-8992</li>\n</ul>\n\n<p style=\"margin-left:40px\"><strong>Note:</strong>&nbsp;If&nbsp;version 8.4 was previously installed, then it is not necessary to upgrade to version 8.4 (D).</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2019 OS</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"}],"sw_keys":[{"name":"NVMePIC-Gen9","sw_key_expectedpath":"firmware:sd:nvmebackplane"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000GFJTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGNTG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-3047464a5445","Version":"HPG5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MM1000GFJTE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MM1000GFJTE Drive</p>\n\n<p><strong><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG5<br />\n<br />\n<strong><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG4<br />\n<br />\n<strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG4<br />\n<br />\n<strong><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"17291449","datemodified":"2021-08-27T06:39:37","file_list":["/CP048389_BUILD_2.data","/CP048389.vmexe","/CP048389.vmexe64","/CP048389.vmfile","/CP048389_VMw.zip","/CP048389.xml","/payload.json","/CP048389_VMw.zip/index.xml","/CP048389_VMw.zip/vendor-index.xml","/CP048389_VMw.zip/metadata.zip","/CP048389_VMw.zip/vib20/CP048389/HPE_bootbank_CP048389_HPG5.2-7.0.0.15843807.vib","/CP048389_VMw.zip/metadata.zip/vendor-index.xml","/CP048389_VMw.zip/metadata.zip/vmware.xml","/CP048389_VMw.zip/metadata.zip/vibs/CP048389--6864932891830580306.xml","/CP048389_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048389_HPG5.2-7.0.0.15843807.xml"],"md5sum":"91119dfc89b4159dae8b8b13aa22056d","name":"CP048389.zip","release":"2021-08-27T06:34:14","revision":"0","sha1sum":"effabef264af177d5626a8d4bf5532c49e5e86a8","size":"16MB","target_guids":["002340a5-4d00-314d-3030-3047464a5445"],"type_of_change":"0","version":"HPG5","vib_list":[{"name":"CP048389","version":"HPG5.2-7.0.0.15843807"}]}],"id":{"product":"c0403221bbc14b609f9dc339f216be5e","version":"111de53e2a9842f58c6e4e37d2e2f5ab"},"installation":{"command":"CP041026.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MM1000GFJTE Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - MM1000GFJTEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MM1000GFJTE","target_guid":"002340a5-4d00-314d-3030-3047464a5445","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T10:44:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MM1000GFJTE","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000300JWBHR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SEnD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57424852","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: EG000300JWBHR"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;EG000300JWBHR&nbsp;Drive<br />\n&nbsp;</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong></p>\n\n<p><strong>&nbsp; &nbsp; &nbsp; </strong>HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp; &nbsp; &nbsp;&nbsp;Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Prolems Fixed:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"3031296","datemodified":"2021-07-24T07:58:29","file_list":["cp048436.xml","cpqsetup.exe","payload.json","setup.dll","T14SEnD5.rel"],"md5sum":"7a344468c12bc6fc2b2fc83e227d26e0","name":"cp048436.exe","release":"2021-07-24T07:51:08","revision":"0","sha1sum":"01c002ad28c9279e32fac2dc9f4f69a8cdb50e78","size":"2MB","target_guids":["452340a5-3047-3030-3330-304a57424852"],"type_of_change":"1","version":"HPD5"}],"id":{"product":"a893ea1028be45a18d3b23d1c1c00c64","version":"852b12a0bf064f4589dcfc2fac261a62"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG000300JWBHR Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EG000300JWBHRドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG000300JWBHR","target_guid":"452340a5-3047-3030-3330-304a57424852","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-10T10:59:11","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>A low-probability, high severity corner case of sustained outer-diameter activity with emergency power off when heads are at the outer diameter prevented heads from parking/latching properly on a few drives in the field.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG000300JWBHR","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The HPE System Health Application and Command Line Utilities (hp-health) is collection of applications and tools which enables monitoring of fans, power supplies, temperature sensors, and other management events.  It also provides collection of command-line utilities: the ProLiant  boot  configuration  utility (hpbootcfg), the ProLiant Management Command Line Interface Utility (hpasmcli), the ProLiant Integrated Management Log (IML) Utility (hplog), and the UID (blue) Light Utility (hpuid)."},{"lang":"ja","x_late":"HPEシステムヘルスアプリケーションおよびコマンドラインユーティリティ（hp-health）パッケージは、アプリケーション、およびファンの監視、電源、温度センサー、およびその他管理イベントを行うツールを集めたものです。また、コマンドラインユーティリティのコレクションを提供します: ProLiantブート構成ユーティリティ（hpbootcfg）、ProLiant管理コマンドラインインターフェイスユーティリティ（hpasmcli）、ProLiantインテグレーテッドマネジメントログ（IML）ユーティリティ（hplog）、およびUID（blue）ライトユーティリティ（hpuid）。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[{"lang":"en","x_late":null}],"files":[{"bytes":"527835","datemodified":"2021-08-25T01:10:26","file_list":["./etc/init.d/hp-asrd","./etc/init.d/hp-health","./opt/hp/hp-health","./opt/hp/hp-health/addons","./opt/hp/hp-health/addons/libcpqci64.a","./opt/hp/hp-health/bin","./opt/hp/hp-health/bin/hp-asrd","./opt/hp/hp-health/bin/hpasmlited","./opt/hp/hp-health/bin/hpasmpld","./opt/hp/hp-health/bin/hpasmxld","./opt/hp/hp-health/examples","./opt/hp/hp-health/examples/lite-mgmt","./opt/hp/hp-health/examples/lite-mgmt/COPYING.txt","./opt/hp/hp-health/examples/lite-mgmt/README.txt","./opt/hp/hp-health/examples/lite-mgmt/cma.conf.nosnmp","./opt/hp/hp-health/examples/lite-mgmt/hpsysmon.sh","./opt/hp/hp-health/hp-health.license","./opt/hp/hp-health/hprpm.xpm","./opt/hp/hp-health/sh","./opt/hp/hp-health/sh/hpasmxld_reset.sh","./sbin/hpasmcli","./sbin/hpbootcfg","./sbin/hplog","./sbin/hpuid","./usr/lib/.build-id","./usr/lib/.build-id/2b","./usr/lib/.build-id/2b/a6f69082f96dd06b29b01747b767175929551e","./usr/lib/.build-id/46","./usr/lib/.build-id/46/4cef12df5fa50cba27d311a2357b6e0bfcaec1","./usr/lib/.build-id/5c","./usr/lib/.build-id/5c/c1f083de2fa461c7d3debb478eec2ff4929f66","./usr/lib/.build-id/6f","./usr/lib/.build-id/6f/f04b3cca0730c373d24d8dba724043a652c7fc","./usr/lib/.build-id/82","./usr/lib/.build-id/82/83f9fbf8af7c9fa4c6eeea9ddac237c47ce94a","./usr/lib/.build-id/8b","./usr/lib/.build-id/8b/c8177f73896d53ea0ab0097dce2d40a84e325c","./usr/lib/.build-id/af","./usr/lib/.build-id/af/068ead6ebb20626fbba843740c24837e3f49a5","./usr/lib/.build-id/ca","./usr/lib/.build-id/ca/8d441539bfd787f203b96b94e89e3a02fe3703","./usr/lib/.build-id/f3","./usr/lib/.build-id/f3/e69d707082f6b0b9a8c310557f055c66a15aa0","./usr/lib/.build-id/f8","./usr/lib/.build-id/f8/9abad5413bca822067c89332169a06972c0317","./usr/lib/.build-id/fa","./usr/lib/.build-id/fa/388ea5030522be7d7d903232d0248236795222","./usr/lib64/libcpqci64.so","./usr/lib64/libcpqci64.so.3","./usr/lib64/libcpqci64.so.3.0","./usr/lib64/libhpasmintrfc64.so","./usr/lib64/libhpasmintrfc64.so.3","./usr/lib64/libhpasmintrfc64.so.3.0","./usr/lib64/libhpev64.so","./usr/lib64/libhpev64.so.1","./usr/lib64/libhpev64.so.1.0","./usr/share/man/man4/hp-health.4.gz","./usr/share/man/man4/hpasmcli.4.gz","./usr/share/man/man7/hp_mgmt_install.7.gz","./usr/share/man/man8/hp-asrd.8.gz","./usr/share/man/man8/hpbootcfg.8.gz","./usr/share/man/man8/hplog.8.gz","./usr/share/man/man8/hpuid.8.gz","./usr/share/smartupdate/hp-health/component.xml","./var/log/hp-health","./var/spool/compaq","./var/spool/hp-health"],"md5sum":"93e1b6e9daf0269fe6c2f4fca28909c8","name":"hp-health-10.93-307.4.rhel8.x86_64.rpm","release":"2021-08-25T01:04:04","revision":"0","sha1sum":"ad5ad38d6daaa9894e14b371d93559bf0497f097","size":"515KB","target_guids":[],"type_of_change":"0","version":"10.9.3"}],"id":{"product":"bd87491089a64d5ebd7c9035cfb17538","version":"78118867a4c74fd6924fb091ddeb73ca"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<P>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</P>\n<P>To install the package type: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;rpm -ivh hp-health-&lt;version&gt;.rpm</P>\n<P>To check whether the package is loaded properly type: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;/etc/init.d/hp-health status</P>\n<P>Additional help is available by typing: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;man hp-health</P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;or</P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;man hp_mgmt_install</P>"},{"lang":"ja","x_late":"<P>システム管理者（root）としてログインし、RPMをご使用のハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</P>\n<P>パッケージをインストールするには、次のようにタイプします。</P>\n<P>      rpm -ivh hp-health-<version>.rpm</P>\n<P>パッケージが正しくロードされているか、以下をタイプして確認します。</P>\n<P>      /etc/init.d/hp-health status</P>\n<P>以下のコマンドを実行してヘルプを参照してください。</P>\n<P>      man hp-health</P>\n<P>            または</P>\n<P>      man hp_mgmt_install</P>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE System Health Application and Command Line Utilities for Red Hat Enterprise Linux 8 Server"},{"lang":"ja","x_late":"HPEシステムヘルスアプリケーションおよびコマンドラインユーティリティ for Red Hat Enterprise Linux 8 Server"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"3309","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3307","subdev":"3309","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-10T13:26:58","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>When a customer queries the HPE Software Delivery Repository (SDR) site and experiences a failure amsd no longer exhibits a&nbsp;segfault.</li>\n\t<li>hp-heath service will no longer crash in a non&nbsp;secure boot environment.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>TBD</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"}],"sw_keys":[{"name":"hp-health","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 546FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-full-rel-2_42_5044-779799-B21_Ax-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C8020","Version":"2.42.5044"},{"DeviceName":"HPE Ethernet 10Gb 2-port 546SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-full-rel-2_42_5044-779793-B21_0A-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C801F","Version":"2.42.5044"},{"DeviceName":"HPE Ethernet 100Gb 1-port 842QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_31_1014-874253-B21_Ax-UEFI-14.24.13-FlexBoot-3.6.403.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900246","Version":"16.31.1014"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640 FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_31_1200-817749-B21_Ax-UEFI-14.24.13-FlexBoot-3.6.403.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D3","Version":"14.31.1200"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_31_1200-817753-B21_Ax-UEFI-14.24.13-FlexBoot-3.6.403.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D4","Version":"14.31.1200"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Mellanox Ethernet only adapter firmware on ESXi 6.7."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 546SFP+ Adapter (779793-B21)</td>\n\t\t\t<td>2.42.5044</td>\n\t\t\t<td>HP_1200111023</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 546FLR-SFP+ Adapter (779799-B21)</td>\n\t\t\t<td>2.42.5044</td>\n\t\t\t<td>HP_2240110004</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)</td>\n\t\t\t<td>14.31.1200</td>\n\t\t\t<td>HP_2690110034</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</td>\n\t\t\t<td>14.31.1200</td>\n\t\t\t<td>HP_2420110034</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter&nbsp;(874253-B21)</td>\n\t\t\t<td>16.31.1014</td>\n\t\t\t<td>HPE0000000014</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"28388668","datemodified":"2021-09-14T03:19:37","file_list":["/CP046584.vmexe","/CP046584.vmfile","/CP046584.xml","/CP046584_VMw.zip","/payload.json","/CP046584_VMw.zip/index.xml","/CP046584_VMw.zip/vendor-index.xml","/CP046584_VMw.zip/metadata.zip","/CP046584_VMw.zip/vib20/CP046584/HPE_bootbank_CP046584_1.0.1-6.7.0.7535516.vib","/CP046584_VMw.zip/metadata.zip/vendor-index.xml","/CP046584_VMw.zip/metadata.zip/vmware.xml","/CP046584_VMw.zip/metadata.zip/bulletins/Smart-Component-CP046584_1.0.1-6.7.0.7535516.xml","/CP046584_VMw.zip/metadata.zip/vibs/CP046584-541119209447487775.xml"],"md5sum":"baddf8ffc1350a60dcfc3ce871c7e336","name":"CP046584.zip","release":"2021-09-14T12:13:15","revision":"0","sha1sum":"45421645008ad1c4e2b7fb840b17b54105caca79","size":"27MB","target_guids":["a6b1a447-382a-5a4f-15B3-1007103C8020","a6b1a447-382a-5a4f-15B3-1007103C801F","a6b1a447-382a-5a4f-15B3-101715900246","a6b1a447-382a-5a4f-15B3-1015159000D3","a6b1a447-382a-5a4f-15B3-1015159000D4"],"type_of_change":"1","version":"1.0.6","vib_list":[{"name":"CP046584","version":"1.0.1-6.7.0.7535516"}]}],"id":{"product":"8f7bfcc1686841199a7eebcfc658f164","version":"ac5310a8bfc0451c8653fa53c8844332"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Offline: &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p>\n\n<p>Remote Online, if the component is supported by SUM but is not yet part of an SPP:<br />\n&nbsp; &nbsp; Download the appropriate SPP<br />\n&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />\n&nbsp; &nbsp; Run SUM<br />\n&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />\n&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />\n&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />\n&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />\n&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />\n&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at: <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p>\n\n<p>Note: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p>\n\n<p>To use HPE Insight Control for vCenter: &nbsp;<br />\n&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />\n&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p>\n\n<p>To update firmware from VMware ESXi operating system on target server: &nbsp;<br />\n&nbsp; &nbsp; Enable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Login as root. (You must be root in order to apply the update) &nbsp;<br />\n&nbsp; &nbsp; Place the Smart Component in a temporary directory<br />\n&nbsp; &nbsp; Check if the nmst module is loaded already: vmkload_mod -l | grep nmst<br />\n&nbsp; &nbsp; If module is not loaded, use the command to load the module: vmkload_mod nmst<br />\n&nbsp; &nbsp; From the same directory, execute the Smart Component. For example: unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe<br />\n&nbsp; &nbsp; Follow the directions given by the Smart Component.<br />\n&nbsp; &nbsp; Logout.<br />\n&nbsp; &nbsp; Disable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Reboot your system, if required, for the firmware update to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (ESXi 6.7) for HPE Mellanox Ethernet only adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-18T07:10:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5044 :</strong></p>\n\n<p>&nbsp; &nbsp;779799-B21 (HPE Ethernet 10G 2-port 546FLR-SFP+ Adapter)<br />\n&nbsp; &nbsp;779793-B21 (HPE Ethernet 10G 2-port 546SFP+ Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.31.1200:</strong></p>\n\n<p>&nbsp; &nbsp;817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</p>\n\n<p>&nbsp;&nbsp;&nbsp;817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following device is updated to 16.29.1016:</strong></p>\n\n<p>&nbsp; &nbsp;874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</p>\n\n<p><strong>New Features and Changes included in version 16.31.1200:</strong></p>\n\n<ul>\n\t<li>Added a new NVconfig per Port for a specific Finisar module. This new NVconfig&nbsp;sets the port to work in AN mode and sets the module to No Data Management Engine (DME). This change&nbsp;does not affect the speed logic, only the forward error correction (FEC) logic (FEC override). <strong>Note:</strong>&nbsp;If the port does not&nbsp;come up, switch to Force mode.&nbsp;</li>\n</ul>\n\n<p><strong>New features and changes included &nbsp;in version 16.29.1016:</strong></p>\n\n<ul>\n\t<li>An option to allow applications to build their own QoS tree over the NIC hierarchy by connecting QPs to responder/requestor Queue Groups.</li>\n\t<li>&quot;InfiniBand&quot; properties set to the Network Device Function Redfish object.</li>\n\t<li>HW support for Flow Metering to utilize Advanced Steering Operation (ASO).&nbsp;HW Flow Meter allows higher scale, more accuracy, and better performance compare to the FW Flow Metering.</li>\n\t<li>Trust level for VFs. Once the VF is trusted, it will get a set of trusted capabilities.</li>\n\t<li>2 new Mini CQE formats: Responder Mini CQE With Flow Tag Layout Responder Mini CQE With l3_l4_info Layout</li>\n\t<li>UCX can now enable AR by exposing Out-Of-Ordering bitmask per SL with &quot;ooo_per_sl&quot; field in the HCA_VPORT context. It can be also queried by running the QUERY_HCA_VPORT_CONTEXT&nbsp;command.</li>\n\t<li>Steering DP hash flow groups.</li>\n\t<li>A new counter per vPort that counts the number of packets that reached the Ethernet RQ but cannot fit into the WQE due to their large size. Additionally, we added the option to control if such packet will cause &ldquo;CQE with Error&rdquo; or &ldquo;CQE_MOCK&rdquo;.</li>\n\t<li>PCIe Rx modifications to prevent the adapter cards from disappearing from the system.</li>\n\t<li>ignore_flow_level is now enabled by the TRUST LEVEL access registry.&nbsp;</li>\n\t<li>cq_overrun counter. The counter represents the number of times CQs enter an error state due to overflow that occur when the device tries to post a CQE into a full CQ buffer.</li>\n\t<li>[Beta]&nbsp;Enabled the capability to allow Virtual Functions to send Pause Frames packets.</li>\n\t<li>Enabled 10/25GbE auto-sensing with 3rd party when using 10/25GbE optical cables.</li>\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Fixes&nbsp;included in&nbsp; firmware version 2.42.5044 :</strong></p>\n\n<ul>\n\t<li>An issue that prevented the firmware from detecting a link_down event thus preventing the IB bond interface from going to a failover mode.</li>\n</ul>\n\n<p><strong>Fixes included&nbsp;in firmware version 14.29.1016:</strong></p>\n\n<ul>\n\t<li>Changed the default value of DCQCN&#39;s (Data center- Quantized Congestion Notification) &nbsp;NP parameter min_time_between_cnps to 4 on all devices to support larger scalability of cluster.</li>\n\t<li>An issue that caused&nbsp;packets to drop due to header size issues and/or failing checks. The issue was caused due to a Linux issue that caused&nbsp;VFs to set the wrong header size value in wqe_inline_header_mode input.</li>\n\t<li>When MKEY_BY_NAME was&nbsp;enabled by NVCONFIG and a large number of VFs were configured, VM restart (VF/PF FLR) will take longer than when MKEY_BY_NAME is disabled.</li>\n\t<li>On rare cases, a fatal error related to errors from the PCI transport layer might be reported during FLR.</li>\n\t<li>&nbsp;An issue that caused&nbsp;the device to go to dead IRISC as one of the firmware semaphores could not be released&nbsp;when a speed change or port state change was triggered.&nbsp;</li>\n</ul>\n\n<p><strong>No fixes are included in firmware version 14.31.1200.</strong></p>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5044 :</strong></p>\n\n<p>&nbsp; &nbsp;779799-B21 (HPE Ethernet 10G 2-port 546FLR-SFP+ Adapter)<br />\n&nbsp; &nbsp;779793-B21 (HPE Ethernet 10G 2-port 546SFP+ Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.31.1200:</strong></p>\n\n<p>&nbsp; &nbsp;817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.31.1200:</strong><br />\n&nbsp; &nbsp;817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following device is updated to 16.31.1014:</strong></p>\n\n<p>&nbsp; &nbsp;874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</p>\n\n<p><br />\n<strong>New features and changes in version 14.31.1200:</strong></p>\n\n<ul>\n\t<li>NVconfig per Port for a Specific Finisar Module: Added a new NVconfig per Port for a specific Finisar module. This new NVconfig sets the port to work in AN mode and sets the module to No DME. This change does not affect the speed logic, only the FEC logic (FEC override).<br />\n\t<strong>Note:</strong>&nbsp;If the port does not go up, switch to Force mode.&nbsp;</li>\n</ul>\n\n<p><strong>New features and changes in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>NIC scheduling feature support has been disabled for non-privileged functions.</li>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>Added support for Enabling/Disabling NIC and RDMA (port/partition) via the UEFI HII system settings.<br />\n\t<strong>Note:</strong>&nbsp;Values set in this option only take effect when is Ethernet mode.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Asymmetrical MSIX Configuration:&nbsp;This feature allows the device to be configured with a different number of MSIX<br />\n\tvectors per physical PCI functions.<br />\n\tTo use this feature, please follow these steps:\n\t<ul>\n\t\t<li>​​​​Clear NUM_PF_MSIX_VALID to disable global symmetrical MSIX configuration.</li>\n\t\t<li>Set PF_NUM_PF_MSIX_VALID to enable asymmetrical per Physical Function MSIX configuration.</li>\n\t\t<li>Configure PF_NUM_PF_MSIX per physical PCI function.</li>\n\t</ul>\n\t</li>\n\t<li>Support for RDMA partitioning and RDMA counters in IB mode.</li>\n\t<li>A new bit (&quot;data_in_order&quot;) was added to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.<br />\n\tPages are returned by the driver to the kernel without issuing the MANAGE_PAGES commands to the firmare.</li>\n\t<li>Enabled UID 0 to create resources with UMEM (User Memory).</li>\n\t<li>Receiving and sending native IB packets from/to the software (including all headers) via raw IBL2 QPs.</li>\n\t<li>RX RDMA NIC flow table on an IB port. Now the software can steer native IB packets to raw IB receive queues according to the DLID and<br />\n\tthe DQPN.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Fixes&nbsp;included in&nbsp; firmware version 2.42.5044 :</strong></p>\n\n<ul>\n\t<li>An issue that prevented the firmware from detecting a link_down event thus preventing the IB bond interface from going to a failover mode.</li>\n</ul>\n\n<p><strong>The following issues have been fixed in version 14.31.1200:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n</ul>\n\n<p style=\"margin-left:40px\"><strong>Additional Fixes included in version 14.31.1200:</strong></p>\n\n<ul>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n</ul>\n\n<p><strong>The following issues have been fixed in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>An assert that was caused when trying to open 1024 functions on the device and the maximum number of functions was 1023.</li>\n\t<li>Occasional performance issues related to RC QPs using E2E-credits (not connected to SRQ and doing send/receive traffic) when the ROCE_ACCL tx_window was enabled.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>A rare issue that caused RX pipe to hang.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>An issue that caused the TX queue to get into an unresponsive state when the VF rate limiter was set.</li>\n</ul>\n\n<p style=\"margin-left:40px\"><strong>Additional Fixes included in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>Disabled the CNP counter &ldquo;rp_cnp_ignored &quot; (triggered by OOS (out-of-sequence)) when all ports are IB.</li>\n\t<li>Fixed the TMP421 sensor temperature reporting.</li>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 System"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"","value":"HPE ProLiant SL4500 Chassis"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_NIC","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO0400JFFCF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3430-304a46464346","Version":"HPD9"},{"DeviceName":"MO0800JFFCH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3830-304a46464348","Version":"HPD9"},{"DeviceName":"MO1600JFFCK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304a4646434b","Version":"HPD9"},{"DeviceName":"MO3200JFFCL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-334f-3230-304a4646434c","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MO0400JFFCF, MO0800JFFCH, MO1600JFFCK, and MO3200JFFCL Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： MO0400JFFCF、MO0800JFFCH、MO1600JFFCKおよびMO3200JFFCLドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MO0400JFFCF, MO0800JFFCH, MO1600JFFCK and MO3200JFFCL Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD9</p>\n\n<p><strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD8</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD8</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp; &nbsp; </strong>None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"5060987","datemodified":"2021-07-23T09:39:55","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-edf6dcd906-HPD9-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-edf6dcd906-HPD9-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-edf6dcd906-HPD9-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-edf6dcd906-HPD9-4.1/CP048209.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-edf6dcd906-HPD9-4.1/GP1635D9.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-edf6dcd906-HPD9-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-edf6dcd906-HPD9-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-edf6dcd906-HPD9-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-edf6dcd906-HPD9-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048209.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048209.scexe"],"md5sum":"e2ffbf5fb4055b5c57343d6d0f667bac","name":"firmware-hdd-edf6dcd906-HPD9-4.1.x86_64.rpm","release":"2021-07-23T09:26:08","revision":"0","sha1sum":"54f903d0803e96e389759959f9fdaeddf18c4afe","size":"4MB","target_guids":["002340a5-4d00-304f-3430-304a46464346","002340a5-4d00-304f-3830-304a46464348","002340a5-4d00-314f-3630-304a4646434b","002340a5-4d00-334f-3230-304a4646434c"],"type_of_change":"1","version":"HPD9"}],"id":{"product":"436670aad3944dd794f4bdcf4feb2b72","version":"9ee85ca102644cdd846ac6f6e433ed42"},"installation":{"command":"CP042217.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MO0400JFFCF, MO0800JFFCH, MO1600JFFCK and MO3200JFFCL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MO0400JFFCF、 MO0800JFFCH、MO1600JFFCK、およびMO3200JFFCLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MO3200JFFCL","target_guid":"002340a5-4d00-334f-3230-304a4646434c","type":"sas"},{"id":"MO1600JFFCK","target_guid":"002340a5-4d00-314f-3630-304a4646434b","type":"sas"},{"id":"MO0400JFFCF","target_guid":"002340a5-4d00-304f-3430-304a46464346","type":"sas"},{"id":"MO0800JFFCH","target_guid":"002340a5-4d00-304f-3830-304a46464348","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T11:48:38","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MO0800JFFCH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO3200JFFCL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO0400JFFCF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO1600JFFCK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GZCNE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K511HPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-30475a434e45","Version":"HPG1"},{"DeviceName":"VK000960GZCNF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K511HPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-30475a434e46","Version":"HPG1"},{"DeviceName":"VK001920GZCNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K511HPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-30475a434e48","Version":"HPG1"},{"DeviceName":"VK003840GZCNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K511HPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-30475a434e4b","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000480GZCNE、VK000960GZCNF、VK001920GZCNHおよびVK003840GZCNK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"9775273","datemodified":"2021-07-27T13:12:05","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG1-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG1-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG1-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG1-2.1/CP049154.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG1-2.1/K511HPG1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG1-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG1-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG1-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG1-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049154.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049154.scexe"],"md5sum":"18b9631c3d9dfc4ce1df606041c92bd7","name":"firmware-hdd-befd42bd64-HPG1-2.1.x86_64.rpm","release":"2021-07-27T12:57:05","revision":"0","sha1sum":"eb5ff0c1f40dccd5d6a2562e2a9daf309d018349","size":"9MB","target_guids":["562340a5-304b-3030-3438-30475a434e45","562340a5-304b-3030-3936-30475a434e46","562340a5-304b-3130-3932-30475a434e48","562340a5-304b-3330-3834-30475a434e4b"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"8f93dddcb15744aab6bb426d5e84dee8","version":"eb5cb9d3c20740e2a29a53525473923e"},"installation":{"command":"CP043255.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/jp/servers/spp_dl　\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for Linux (x64) - VK000480GZCNE、VK000960GZCNF、VK001920GZCNHおよびVK003840GZCNKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VK000480GZCNE","target_guid":"562340a5-304b-3030-3438-30475a434e45","type":"sata"},{"id":"VK000960GZCNF","target_guid":"562340a5-304b-3030-3936-30475a434e46","type":"sata"},{"id":"VK001920GZCNH","target_guid":"562340a5-304b-3130-3932-30475a434e48","type":"sata"},{"id":"VK003840GZCNK","target_guid":"562340a5-304b-3330-3834-30475a434e4b","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-27T12:54:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>The FW version is Changed from HPG0 to HPG1. Changed the thermal throttling scheme. SMART 60℃ was matched with Tcase 70℃ and Run the thermal throttling at SMART 65℃.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK000960GZCNF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GZCNE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GZCNK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GZCNH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"XP0120GFJSL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"ASAXHPS4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5800-3050-3132-3047464a534c","Version":"HPS4"},{"DeviceName":"XP0240GFJSN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"ASAXHPS4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5800-3050-3234-3047464a534e","Version":"HPS4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SATA drive models: XP0120GFJSL and XP0240GFJSN"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。XP0120GFJSLおよびXP0240GFJSN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - &nbsp;XP0120GFJSL and XP0240GFJSN Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPS4<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5449171","datemodified":"2021-07-23T09:13:08","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-d355375539-HPS4-10.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-d355375539-HPS4-10.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-d355375539-HPS4-10.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d355375539-HPS4-10.1/ASAXHPS4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-d355375539-HPS4-10.1/CP048198.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-d355375539-HPS4-10.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d355375539-HPS4-10.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-d355375539-HPS4-10.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-d355375539-HPS4-10.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048198.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048198.scexe"],"md5sum":"be2619f0c43e74eaccd44691cdcaf4d1","name":"firmware-hdd-d355375539-HPS4-10.1.x86_64.rpm","release":"2021-07-23T09:00:10","revision":"0","sha1sum":"a1da50a9e07e341b84c26c6ca1fa8d16c3a25f0e","size":"5MB","target_guids":["002340a5-5800-3050-3132-3047464a534c","002340a5-5800-3050-3234-3047464a534e"],"type_of_change":"1","version":"HPS4"}],"id":{"product":"426a1761f14e4ba492f138726a8bcbf6","version":"1c94f0fbf9fc4304b373f502fd5c1f3b"},"installation":{"command":"CP040296.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - XP0120GFJSL and XP0240GFJSN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - XP0120GFJSLおよびXP0240GFJSNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"XP0120GFJSL","target_guid":"002340a5-5800-3050-3132-3047464a534c","type":"sata"},{"id":"XP0240GFJSN","target_guid":"002340a5-5800-3050-3234-3047464a534e","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T10:59:23","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"XP0120GFJSL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"XP0240GFJSN","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"8739152","datemodified":"2021-05-17T21:41:47","file_list":["/CP047858.vmexe","/CP047858.vmexe64","/CP047858.vmfile","/CP047858.xml","/README.txt"],"md5sum":"193ca1a14d2fce049b674d4969ea5544","name":"CP047858.zip","release":"2021-05-18T02:38:19","revision":"0","sha1sum":"91d238b1746998b84e4337e84bfb0223c4c52247","size":"8MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021","vib_list":[]}],"id":{"product":"2d670e4a587b4b0daab7ed709579acb1","version":"d9751600f6cb452aa7d3209fa0551ca5"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component requires that the CRU driver be loaded before the component can run.</p>\n\n<p>The minimum CRU version for 5.1 is 5.0.3.9.<br />\nThe minimum CRU version for 5.5 is 5.5.4.1.<br />\nThe minimum CRU version for 6.0 is 6.0.8.<br />\nThe minimum CRU version for 6.5 is 6.5.8.<br />\nThe minimum CRU version for 6.7 is 6.7.10.<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>SPP Offline mode boots a special Linux OS environment, thus the Linux Components are used, not the VMware Components</li>\n</ul>\n\n<p><br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Download the appropriate SPP</li>\n\t<li>Add the component to the SPP</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run&nbsp; SUM</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps to complete the firmware update</li>\n\t<li>Refer to the SPP documentation for detailed instructions at:&nbsp; <a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Component ( CPxxxxxx.zip) in a temporary directory</li>\n\t<li>From the same directory, unzip the Component:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>To perform the standalone installation, execute the command:<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>Follow the directions given by the Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system for the firmware update to take effect</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、実行する前にCRUドライバーがロードされている必要があります。</p>\n\n<p>5.1の最小CRUバージョンは5.0.3.9です。<br />\n5.5の最小CRUバージョンは5.5.4.1です。<br />\n6.0の最小CRUバージョンは6.0.8です。<br />\n6.5の最小CRUバージョンは6.5.8です。<br />\n6.7の最小CRUバージョンは6.7.10です。<br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMwareコンポーネントではなく、Linuxコンポーネントが用いられます</li>\n</ul>\n\n<p><br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします</li>\n\t<li>SPPにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします</li>\n\t<li>SUMを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います</li>\n\t<li>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>コンポーネント (CPxxxxxx.zip)を一時ディレクトリに置きます</li>\n\t<li>同じディレクトリからコンポーネントをunzipします:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>スタンドアロンのインストールを行うために、次のコマンドを実行します：<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>コンポーネントの指示に従います</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n\t<li>システムを再起動し、ファームウェアのアップデートを有効にします</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware - HPE ProLiant DL120 Gen9 (P86) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for VMware - HPE ProLiant DL120 Gen9（P86）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"5","minor":"1","name":"VMware vSphere 5.1","platform":"vmware_esx_server","sr":"OEM"},{"major":"5","minor":"5","name":"VMware vSphere 5.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-05T03:59:08","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"}],"sw_keys":[{"name":"P86","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB8000JFECQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRPSD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3842-3030-304a46454351","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB8000JFECQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB8000JFECQ Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD4</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong>&nbsp;&nbsp;&nbsp;&nbsp;<br />\n&nbsp; &nbsp; &nbsp; None&nbsp;<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3806464","datemodified":"2021-07-25T16:11:55","file_list":["cp048619.xml","cpqsetup.exe","payload.json","setup.dll","SMKRPSD7.rel"],"md5sum":"59420dcec9ba31208d59139a3c28c3e3","name":"cp048619.exe","release":"2021-07-25T16:03:08","revision":"0","sha1sum":"c717c10a7d6431938c8d00f3a936358058bec0ba","size":"3MB","target_guids":["002340a5-4d00-3842-3030-304a46454351"],"type_of_change":"1","version":"HPD7"}],"id":{"product":"b23cbcef087a471c988db0eccfc20ffd","version":"b97feeb703714eca9e8af78cd1f5f0f5"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB8000JFECQ Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB8000JFECQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB8000JFECQ","target_guid":"002340a5-4d00-3842-3030-304a46454351","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T12:38:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB8000JFECQ","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000960GXCLD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5210AG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304758434c44","Version":"HPG2"},{"DeviceName":"VK001920GXCGP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5210AG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304758434750","Version":"HPG2"},{"DeviceName":"VK003840GXCGQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5210AG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304758434751","Version":"HPG2"},{"DeviceName":"VK007680GXCGR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5210AG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-304758434752","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000960GXCLD, VK001920GXCGP, VK003840GXCGQ  and VK007680GXCGR"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;VK000960GXCLD, VK001920GXCGP, VK003840GXCGQ and VK007680GXCGR Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"19634266","datemodified":"2021-08-30T06:26:55","file_list":["/CP049272_BUILD_1.data","/CP049272.vmexe","/CP049272.vmexe64","/CP049272.vmfile","/CP049272_VMw.zip","/CP049272.xml","/payload.json","/CP049272_VMw.zip/index.xml","/CP049272_VMw.zip/vendor-index.xml","/CP049272_VMw.zip/metadata.zip","/CP049272_VMw.zip/vib20/CP049272/HPE_bootbank_CP049272_HPG2.1-7.0.0.15843807.vib","/CP049272_VMw.zip/metadata.zip/vendor-index.xml","/CP049272_VMw.zip/metadata.zip/vmware.xml","/CP049272_VMw.zip/metadata.zip/vibs/CP049272-4756568632553938442.xml","/CP049272_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049272_HPG2.1-7.0.0.15843807.xml"],"md5sum":"fdfce6a19e5f310aa81a571aed1c55b4","name":"CP049272.zip","release":"2021-08-30T06:22:32","revision":"0","sha1sum":"e4405f30fa8b58dce456a91b1cfbbca7e40bd034","size":"18MB","target_guids":["562340a5-304b-3030-3936-304758434c44","562340a5-304b-3130-3932-304758434750","562340a5-304b-3330-3834-304758434751","562340a5-304b-3730-3638-304758434752"],"type_of_change":"1","version":"HPG2","vib_list":[{"name":"CP049272","version":"HPG2.1-7.0.0.15843807"}]}],"id":{"product":"966974f2ab9a4657a90227f18e4fbb1c","version":"57123cae240648b581d7f19985a087d2"},"installation":{"command":"CP043256.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK000960GXCLD, VK001920GXCGP, VK003840GXCGQ  and VK007680GXCGR Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VK000960GXCLD","target_guid":"562340a5-304b-3030-3936-304758434c44","type":"sata"},{"id":"VK007680GXCGR","target_guid":"562340a5-304b-3730-3638-304758434752","type":"sata"},{"id":"VK001920GXCGP","target_guid":"562340a5-304b-3130-3932-304758434750","type":"sata"},{"id":"VK003840GXCGQ","target_guid":"562340a5-304b-3330-3834-304758434751","type":"sata"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-13T13:53:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK003840GXCGQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GXCGP","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK007680GXCGR","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GXCLD","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GWAYN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHHaseFG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-30475741594e","Version":"HPG5"},{"DeviceName":"MB008000GWAYL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHHaseFG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-30475741594c","Version":"HPG5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB010000GWAYN and MB008000GWAYL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB010000GWAYN and MB008000GWAYL Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG4</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>This code corrects a potential data integrity issue related to unaligned write commands.This issue was only found in supplier ongoing lab testing.</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"18543172","datemodified":"2021-08-26T12:28:13","file_list":["/CP048333_BUILD_2.data","/CP048333.vmexe","/CP048333.vmexe64","/CP048333.vmfile","/CP048333_VMw.zip","/CP048333.xml","/payload.json","/CP048333_VMw.zip/index.xml","/CP048333_VMw.zip/vendor-index.xml","/CP048333_VMw.zip/metadata.zip","/CP048333_VMw.zip/vib20/CP048333/HPE_bootbank_CP048333_HPG5.2-7.0.0.15843807.vib","/CP048333_VMw.zip/metadata.zip/vendor-index.xml","/CP048333_VMw.zip/metadata.zip/vmware.xml","/CP048333_VMw.zip/metadata.zip/vibs/CP048333-362057173162210721.xml","/CP048333_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048333_HPG5.2-7.0.0.15843807.xml"],"md5sum":"dc0e8a643eb9956977dbe83dedb5aa3b","name":"CP048333.zip","release":"2021-08-26T12:23:20","revision":"0","sha1sum":"cd8fd27f2eed521334bfac8d111c29bdf9b506fd","size":"17MB","target_guids":["4d2340a5-3042-3031-3030-30475741594e","4d2340a5-3042-3830-3030-30475741594c"],"type_of_change":"2","version":"HPG5","vib_list":[{"name":"CP048333","version":"HPG5.2-7.0.0.15843807"}]}],"id":{"product":"d31e8e30285a40108d05d6b3dc709695","version":"139c07b1e0af4fcd87a87d9e7a0608e1"},"installation":{"command":"CP040638.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB010000GWAYN and MB008000GWAYL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB010000GWAYNおよびMB008000GWAYLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB010000GWAYN","target_guid":"4d2340a5-3042-3031-3030-30475741594e","type":"sata"},{"id":"MB008000GWAYL","target_guid":"4d2340a5-3042-3830-3030-30475741594c","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-05T19:22:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>This code corrects a potential data integrity issue related to unaligned write commands.  This issue was only found in supplier ongoing lab testing.</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>\n\t<p>This code corrects a potential data integrity issue related to unaligned write commands.This issue was only found in supplier ongoing lab testing.</p>\n\t</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB010000GWAYN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB008000GWAYL","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Intel i40e Ethernet NICs running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 8で動作するHPE Intel i40e Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"295749","datemodified":"2021-09-05T12:38:18","file_list":["./etc/depmod.d/hp-i40e.conf","./etc/dracut.conf.d/hp-i40e-oob.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/hp-i40e","./lib/modules/4.18.0-240.el8.x86_64/extra/hp-i40e/i40e.ko","./usr/share/smartupdate/kmod-hp-i40e/component.xml"],"md5sum":"0c3c555ad8ea0af58aa24ac5edb03c86","name":"kmod-hp-i40e-2.14.13-1.rhel8u3.x86_64.rpm","release":"2021-09-05T12:28:23","revision":"0","sha1sum":"3f2036a36fc6dc0af1e5a0d73fc92337530a42db","size":"288KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec243e7654"],"type_of_change":"0","version":"2.14.13-1"},{"bytes":"295642","datemodified":"2021-09-05T12:39:38","file_list":["./etc/depmod.d/hp-i40e.conf","./etc/dracut.conf.d/hp-i40e-oob.conf","./lib/modules/4.18.0-193.el8.x86_64","./lib/modules/4.18.0-193.el8.x86_64/extra","./lib/modules/4.18.0-193.el8.x86_64/extra/hp-i40e","./lib/modules/4.18.0-193.el8.x86_64/extra/hp-i40e/i40e.ko","./usr/share/smartupdate/kmod-hp-i40e/component.xml"],"md5sum":"575b020be09d65e65505adbb8801b7fd","name":"kmod-hp-i40e-2.14.13-1.rhel8u2.x86_64.rpm","release":"2021-09-05T12:28:23","revision":"0","sha1sum":"c5fec73aa9052b5a0f019fe3928aaf6d285d510d","size":"288KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec243e7654"],"type_of_change":"0","version":"2.14.13-1"}],"id":{"product":"79178f63311141b49420306fd1de47d3","version":"5cca03ce534e40c98663b1eb3a5cfd1f"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"},{"lang":"ja","x_late":"<p>インストールのノートについてREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Intel i40e Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE Intel i40eドライバー for Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"},{"dev":"1572","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1572808600a1","type":"pci","ven":"8086"},{"dev":"1572","subdev":"0008","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-157280860008","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"1581","subdev":"00F8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1581159000f8","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-10-02T12:56:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue where the driver could result in kernel instability under heavy network conditions. Recommend to use this version 2.14.13(or later) as suggested by Intel TA-256(Technical Advisory).</p>\n"},{"curr_enhancements_x_late":"<p>This product supports the following new server:</p>\n\n<ul>\n\t<li>HPE ProLiant DL20 Gen10 Plus Server</li>\n\t<li>HPE ProLiant ML30 Gen10 Plus Server&nbsp;<br />\n\t&nbsp;</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-hp-i40e","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-i40e","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-i40e","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-i40e","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO007680JWCNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633HD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304a57434e4b","Version":"HPD8"},{"DeviceName":"VO015300JWCNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633HD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3330-304a57434e4c","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VO007680JWCNK and VO015300JWCNL"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO007680JWCNKおよびVO015300JWCNL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi&nbsp;- VO007680JWCNK and VO015300JWCNL&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16980990","datemodified":"2021-08-27T10:56:34","file_list":["/CP048415_BUILD_3.data","/CP048415.vmexe","/CP048415.vmexe64","/CP048415.vmfile","/CP048415_VMw.zip","/CP048415.xml","/payload.json","/CP048415_VMw.zip/index.xml","/CP048415_VMw.zip/vendor-index.xml","/CP048415_VMw.zip/metadata.zip","/CP048415_VMw.zip/vib20/CP048415/HPE_bootbank_CP048415_HPD8.3-7.0.0.15843807.vib","/CP048415_VMw.zip/metadata.zip/vendor-index.xml","/CP048415_VMw.zip/metadata.zip/vmware.xml","/CP048415_VMw.zip/metadata.zip/vibs/CP048415--1852356481861341247.xml","/CP048415_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048415_HPD8.3-7.0.0.15843807.xml"],"md5sum":"d7f759a3c3de9d9197c1a6bcb29e1640","name":"CP048415.zip","release":"2021-08-27T10:51:43","revision":"0","sha1sum":"805a8a018b087473ed649622a2bd4499c89c49d4","size":"16MB","target_guids":["562340a5-304f-3730-3638-304a57434e4b","562340a5-304f-3531-3330-304a57434e4c"],"type_of_change":"2","version":"HPD8","vib_list":[{"name":"CP048415","version":"HPD8.3-7.0.0.15843807"}]}],"id":{"product":"e4b6ca2c49674535912553cede176d16","version":"99a92c6e4802423b931489959d31208d"},"installation":{"command":"CP042626.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VO007680JWCNK and VO015300JWCNL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - VO007680JWCNKおよびVO015300JWCNLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VO015300JWCNL","target_guid":"562340a5-304f-3531-3330-304a57434e4c","type":"sas"},{"id":"VO007680JWCNK","target_guid":"562340a5-304f-3730-3638-304a57434e4b","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T11:19:01","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO007680JWCNK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO015300JWCNL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWCBC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRN620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757434243","Version":"HPG6"},{"DeviceName":"MB002000GWCBD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRN620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757434244","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB001000GWCBC and MB002000GWCBD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB001000GWCBC and MB002000GWCBD Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG4</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG4<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"18200032","datemodified":"2021-08-30T18:51:11","file_list":["/CP048300_BUILD_3.data","/CP048300.vmexe","/CP048300.vmexe64","/CP048300.vmfile","/CP048300_VMw.zip","/CP048300.xml","/payload.json","/CP048300_VMw.zip/index.xml","/CP048300_VMw.zip/vendor-index.xml","/CP048300_VMw.zip/metadata.zip","/CP048300_VMw.zip/vib20/CP048300/HPE_bootbank_CP048300_HPG6.3-7.0.0.15843807.vib","/CP048300_VMw.zip/metadata.zip/vendor-index.xml","/CP048300_VMw.zip/metadata.zip/vmware.xml","/CP048300_VMw.zip/metadata.zip/vibs/CP048300-2745758003451962957.xml","/CP048300_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048300_HPG6.3-7.0.0.15843807.xml"],"md5sum":"ffa7e69de8fba17bd5180f536a7a48a7","name":"CP048300.zip","release":"2021-08-30T18:46:14","revision":"0","sha1sum":"fb2ac808efd24d46ee538baf04bf4b2256450c80","size":"17MB","target_guids":["4d2340a5-3042-3130-3030-304757434243","4d2340a5-3042-3230-3030-304757434244"],"type_of_change":"1","version":"HPG6","vib_list":[{"name":"CP048300","version":"HPG6.3-7.0.0.15843807"}]}],"id":{"product":"fcc57b2588b04f54a01cb383a7a5a458","version":"a4094da3c41e485c97f5344adb7891d6"},"installation":{"command":"CP040784.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB001000GWCBC and MB002000GWCBD Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor ESXi - MB001000GWCBCおよびMB002000GWCBDドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB001000GWCBC","target_guid":"4d2340a5-3042-3130-3030-304757434243","type":"sata"},{"id":"MB002000GWCBD","target_guid":"4d2340a5-3042-3230-3030-304757434244","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-03T10:00:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB001000GWCBC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB002000GWCBD","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This component package contains the HPE iavf driver for Intel i40ea and Intel i40eb Ethernet NICs running under Microsoft Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージには、Microsoft Windows Server 2019で動作しているIntel i40eaおよびIntel i40eb Ethernet NIC用のHPE iavfドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1319376","datemodified":"2021-01-09T08:26:15","file_list":["cp045010.xml","cpqsetup.exe","cp_data.xml","iavf68.cat","iavf68.din","iavf68.inf","iavf68.sys","iavfmsg.dll","install.xml","nicdrvr.dll"],"md5sum":"31bcca242202a17fd50097031e7add33","name":"cp045010.exe","release":"2021-01-09T08:07:04","revision":"0","sha1sum":"a1b7f2d4d3011e847a7c50e583dac81478da4469","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec76b7ab5a"],"type_of_change":"0","version":"1.12.9.0"}],"id":{"product":"e774fea9b642407a9f2687df296d352e","version":"8dd3d9b9dea24c70998a024a2d8c2510"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel iavf Driver for Windows Server 2019"},{"lang":"ja","x_late":"HPE Intel iavfドライバー for Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"37CD","subdev":"0000","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"37CD","subdev":"0001","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-37cd80860001","type":"pci","ven":"8086"},{"dev":"1571","subdev":"0001","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-157180860001","type":"pci","ven":"8086"},{"dev":"1571","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"154c","subdev":"0000","subven":"103c","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product is updated to maintain compatibility with updated Windows installation library iavfmsg.dll.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"iavf68.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 adapter cards."},{"lang":"ja","x_late":"このRPMには、サポートされているHPE Mellanox ConnectX-4、ConnectX-5、およびConnectX-6アダプターカード用のHPEによるテストと承認済みのLinuxベースMellanox RoCE（RDMA over Converged Ethernet）ドライバーが含まれます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1629717","datemodified":"2021-07-21T06:51:50","file_list":["./etc/depmod.d/zz01-mlnx-ofa_kernel-auxiliary.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-bnxt_re.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-efa.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-hfi1.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-i40iw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ipoib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_iser.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_isert.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srp.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srpt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_umad.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_uverbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cxgb4.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx_compat.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxdevm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxfw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvme-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvmet-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-opa_vnic.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-qedr.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_rxe.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdmavt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rpcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-siw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-svcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-usnic_verbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-vmw_pvrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-xprtrdma.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/compat","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/compat/mlx_compat.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/base","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/base/auxiliary.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_cm.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_core.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_ucm.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_umad.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/iw_cm.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_cm.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa/efa.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/i40iw","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/siw","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/siw/siw.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host/nvme-rdma.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/net","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/net/mlxdevm","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/net/mlxdevm/mlxdevm.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/kmod-mlnx-ofa_kernel/component.xml"],"md5sum":"40d550438701e51c9942803c522763c6","name":"kmod-mlnx-ofa_kernel-5.4-OFED.5.4.1.0.3.1.rhel8u3.x86_64.rpm","release":"2021-07-21T05:40:04","revision":"0","sha1sum":"7b46a2cb5510afd095f765ea9cdda3dc02c0922a","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"5.4"},{"bytes":"1358382","datemodified":"2021-07-21T06:53:12","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/rdma","./etc/rdma/mlx4.conf","./etc/rdma/modules","./etc/rdma/modules/rdma.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/70-persistent-ipoib.rules","./lib/udev/auxdev-sf-netdev-rename","./lib/udev/mlnx_bf_udev","./lib/udev/rules.d/82-net-setup-link.rules","./lib/udev/rules.d/83-mlnx-sf-name.rules","./lib/udev/rules.d/90-ib.rules","./lib/udev/sf-rep-netdev-rename","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/mlnx_bf_configure_ct","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_perf","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/include/mellanox/dpcp.h","./usr/lib/.build-id","./usr/lib/.build-id/30","./usr/lib/.build-id/30/b8e0f63d89ebf81110fc4d333a76098c371b92","./usr/lib/.build-id/69","./usr/lib/.build-id/69/72aa660471d23ab45e69f0faa73601b4e82f94","./usr/lib/.build-id/6b","./usr/lib/.build-id/6b/8aa7e55550cb1c90c661447dfaf3f3a37fa60b","./usr/lib/.build-id/70","./usr/lib/.build-id/70/502f22187a3457caf06772d41a77b3b6dab45d","./usr/lib/.build-id/87","./usr/lib/.build-id/87/c3eab39b178189d1e807e5e905d580fbbedbd2","./usr/lib/.build-id/ba","./usr/lib/.build-id/ba/0de28467864160bd85353b81c4fac993fd0208","./usr/lib/.build-id/d7","./usr/lib/.build-id/d7/bca38ebb069b7af0080b86b343f487bcb0dd4d","./usr/lib/.build-id/d8","./usr/lib/.build-id/d8/572b2059c95ac18336e0c775d7ce97e81d2118","./usr/lib/.build-id/dd","./usr/lib/.build-id/dd/67acb771666168a3bc82ba351235ac2a3a3f39","./usr/lib/.build-id/f3","./usr/lib/.build-id/f3/0122027b38a7a4498f348b83362158ac6690d1","./usr/lib/dracut","./usr/lib/dracut/modules.d","./usr/lib/dracut/modules.d/05rdma","./usr/lib/dracut/modules.d/05rdma/module-setup.sh","./usr/lib/modprobe.d","./usr/lib/modprobe.d/libmlx4.conf","./usr/lib/python3.6/site-packages/dcbnetlink.py","./usr/lib/python3.6/site-packages/genetlink.py","./usr/lib/python3.6/site-packages/mlnx_tools-5.2.0-py3.6.egg-info","./usr/lib/python3.6/site-packages/netlink.py","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/rdma-ndd.service","./usr/lib/systemd/system/vma.service","./usr/lib/udev/rdma_rename","./usr/lib/udev/rules.d","./usr/lib/udev/rules.d/60-rdma-ndd.rules","./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules","./usr/lib/udev/rules.d/75-rdma-description.rules","./usr/lib/udev/rules.d/90-rdma-umad.rules","./usr/lib64/libdpcp.so","./usr/lib64/libdpcp.so.1","./usr/lib64/libdpcp.so.1.1.12","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.35.0","./usr/lib64/libibverbs","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.14.35.0","./usr/lib64/libibverbs/libmlx5-rdmav34.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.19.35.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.3.35.0","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.3.1","./usr/lib64/rsocket","./usr/lib64/rsocket/librspreload.so","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/libexec/mlx4-setup.sh","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/ibdev2netdev","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/rdma-ndd","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vmad","./usr/share/doc/dpcp","./usr/share/doc/dpcp/README","./usr/share/doc/libibverbs","./usr/share/doc/libibverbs/libibverbs.md","./usr/share/doc/librdmacm","./usr/share/doc/librdmacm/librdmacm.md","./usr/share/doc/libvma","./usr/share/doc/libvma/CHANGES","./usr/share/doc/libvma/README","./usr/share/doc/mlnx-tools","./usr/share/doc/mlnx-tools/ib2ib_setup.txt","./usr/share/doc/rdma-core","./usr/share/doc/rdma-core/COPYING.BSD_FB","./usr/share/doc/rdma-core/COPYING.BSD_MIT","./usr/share/doc/rdma-core/COPYING.GPL2","./usr/share/doc/rdma-core/COPYING.md","./usr/share/doc/rdma-core/README.md","./usr/share/doc/rdma-core/tag_matching.md","./usr/share/doc/rdma-core/udev.md","./usr/share/licenses/dpcp","./usr/share/licenses/dpcp/LICENSE","./usr/share/licenses/libvma","./usr/share/licenses/libvma/COPYING","./usr/share/man/man7/rsocket.7.gz","./usr/share/man/man7/vma.7.gz","./usr/share/man/man8/ib2ib_setup.8.gz","./usr/share/man/man8/rdma-ndd.8.gz","./usr/share/man/man8/vmad.8.gz","./usr/share/mlnx_ofed/mlnx_bf_assign_ct_cores.sh","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml","./usr/lib/python3.6/site-packages/__pycache__/dcbnetlink.cpython-36.opt-1.pyc","./usr/lib/python3.6/site-packages/__pycache__/dcbnetlink.cpython-36.pyc","./usr/lib/python3.6/site-packages/__pycache__/genetlink.cpython-36.opt-1.pyc","./usr/lib/python3.6/site-packages/__pycache__/genetlink.cpython-36.pyc","./usr/lib/python3.6/site-packages/__pycache__/netlink.cpython-36.opt-1.pyc","./usr/lib/python3.6/site-packages/__pycache__/netlink.cpython-36.pyc"],"md5sum":"8eb70476d6ae1dad29609beb3a194234","name":"mlnx-ofa_kernel-5.4-OFED.5.4.1.0.3.1.rhel8u3.x86_64.rpm","release":"2021-07-21T05:40:04","revision":"0","sha1sum":"317926b446e59e03e5b6f681e7345c11a562190a","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"5.4"}],"id":{"product":"3a09afbc8f48497998b1cf5fc8b9ef29","version":"b397aa2eb84f46feb089f3939728da62"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)","OSVersion":{"name":"Linux","value":"6.9"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)","OSVersion":{"name":"Linux","value":"6.10"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)","OSVersion":{"name":"Linux","value":"7.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)","OSVersion":{"name":"Linux","value":"7.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-5.4&quot;&nbsp;RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using kernel version &nbsp;4.18.0-240.el8.x86_64&nbsp;or any future errata:<br />\n<br />\n<strong># rpm -Uvh&nbsp;kmod-mlnx-ofa_kernel-5.4-OFED.5.4-0.5.1.1.rhel8u3.x86_64.rpm mlnx-ofa_kernel-5.4-OFED.5.4-0.5.1.1.rhel8u3.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 Adapters for Red Hat Enterprise Linux 8 Update 3 (x86_64)"},{"lang":"ja","x_late":"HPE Mellanox RoCE（RDMA over Converged Ethernet）Driver for Mellanox ConnectX-4、ConnectX-5、ConnectX-6 Adapters for Red Hat Enterprise Linux 8 Update 3 (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"101f","subdev":"0012","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30012","type":"pci","ven":"15b3"},{"dev":"101f","subdev":"0007","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30007","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"032D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-10171590032d","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T17:11:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Changes and new features in HPE Mellanox RoCE driver&nbsp;version 5.2:</strong></p>\n\n<p><strong>For ConnectX-5 Adapters and above:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>CQE compression support for Rx multi-strides packets.</li>\n\t\t<li>Configuring QoS on a single QP or on a group of QPs.</li>\n\t\t<li>Encap/decap hardware offload of IPv4 traffic over MPLS-over-UDP. This can be used in networks with MPLS routers to achieve more efficient routing.</li>\n\t\t<li>Connection tracking rules on VFs to forward traffic from one VF to the other.</li>\n\t\t<li>Offloading sFlow sampling rules.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For ConnectX-5 Adapters and ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>A locking mechanism to enable parallel insertion of rules into the software steering using the mlx5dv_dr API. The parallel insertion improves the insertion rate and takes place when adding Rx and Tx rules via the FDB domain.</li>\n\t\t<li>Option to match mlx5dv_dr API on Geneve tunnel using a dynamic flex parser. The option header consists of class, type, length and data. The parser should be configured using devx command, after which a rule can be created to match on parser ID and data.</li>\n\t\t<li>Geneve tunneling offload, including matching on extension header.</li>\n\t\t<li>Parallel insertion and deletion of offloaded rules using multiple&nbsp;OVS threads.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>[Beta] Modify GTP-U TEID. This support requires flex parser&nbsp;configuration.</li>\n\t\t<li>[Beta] Improved performance of OVS Connection Tracking flows by&nbsp;enabling the merge of the multi-table flow matches and actions into one joint flow.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Dx Adapters and above:</strong></p>\n\n<p>Added support for the following features:</p>\n\n<ul>\n\t<li>Transmitted packet timestamping accuracy can be improved when using a timestamp generated at the port level instead of a timestamp generated upon CQE creation. Tx port time-stamping better reflects the actual time of a packet&#39;s transmission. This feature is disabled by default. The feature can be enabled or disabled using the following command. ethtool --set-priv-flags tx_port_ts on / off.</li>\n\t<li>Offloading tunnel rules when the source interface is VF (in addition to uplink) in the Hypervisor.</li>\n\t<li>Using Mirroring Offload with Connection Tracking.</li>\n\t<li>ASO flow meter using the mlx5dv_dr API, which allows for monitoring the packet rate for specific flows. When a packet hits a flow that is connected to a flow meter, the rate of packets through this meter is evaluated, and the packet is marked with a color copied into one of the C registers, according to the current rate compared to the reference rate.</li>\n\t<li>ASO first hit using the mlx5dv_dr API, which allows for tracking rule hits by packets. When a packet hits a rule with the ASO first hit action, a flag is set indicating this event, and the original value of the flag is copied to one of the C registers.</li>\n\t<li>mlx5dv_dr API support for matching on a new field &quot;gtpu_first_ext_dw_0&quot;. This field enables packet filtering based on the GTP-U first extension header (first dword only). To enable parsing of tunnel GTP-U extension header, run the following command. ./cloud_fw_reset.py FLEX_PARSER_PROFILE_ENABLE=3.</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Lx Adapters and above:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>IPsec full offload support for extended sequence number, replay protection window and lifetime packet limit.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;All HCA&#39;s:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>New query GID API that allows for querying a single GID entry by its port and GID index, or querying for all GID tables of a specific device. This API works over ioctl instead of sysfs, which accelerates the querying process.</li>\n\t\t<li>Performing multi-host firmware reset in order to upgrade the device firmware. Firmware reset loads the new firmware in case it was burnt on the flash and was pending activation, and reload.</li>\n\t\t<li>[Alpha] Firmware live patching in the driver. Live patching updates the firmware without the need to perform firmware reset. However, it can only be applied in scenarios where the difference between the current and new firmware versions are minor, which is decided upon by the firmware itself.</li>\n\t\t<li>devlink tool for performing firmware reset in order to upgrade the device firmware. Firmware reset loads the new firmware in case it was burnt on the flash and was pending activation, and reloads the current firmware image from the flash in case no new firmware was pending. For further information, please refer to the the devlink man page.</li>\n\t\t<li>A resiliency mechanism for the driver to manually poll the command event queue (EQ) in case of a command timeout. In case the resiliency mechanism finds unhandled event queue entry (EQE) due to a lost interrupt, the driver will handle it, after which the command interface returns to a healthy state.</li>\n\t\t<li>Setting a sniffer private flag is deprecated and no longer required. In order to capture offloaded/RoCE traffic, tcpdump can now be run on the RDMA device.</li>\n\t\t<li>Added per-port reporters to devlink health to manage per-port health activities. Users can now access the devlink port reporters by specifying the port index in addition to the device devlink name through the devlink health commands API. This update was first introduced in iproute2 v5.8. As part of this feature, mlx5e Tx and Rx reporters are now redefined as devlink port reporters. For examples, please see devlink-health manpage</li>\n\t\t<li>Optimized memory consumption of memory registration in huge page systems. As an example, in a 2MB huge page system, 600 MB would be saved for 100 GB memory registration.</li>\n\t\t<li>mlx5dv API to modify the configured UDP source port for RoCE packets of a given RC/UC QP when QP is in RTS state.</li>\n\t\t<li>Accelerating Tx datapath by saving PCI bandwidth and CPU utilization. The savings are achieved by aggregating multiple packets into a single WQE. The feature is driven by xmit_more for certain traffic types, such as UDP.</li>\n\t</ul>\n\t</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 5.2:</strong></p>\n\n<ul>\n\t<li>Clearing min_rate on all SR-IOV legacy VFs after setting min_rate to at least one of the VFs did not disable QoS min_rate.</li>\n\t<li>An empty /usr/src/mlnx-ofa_kernel/default is now no longer created.</li>\n\t<li>An issue where installing packages through a repository failed after generation of metapackages using --add-kernel-support. The failure occurred due to excessive and incorrect Obsolete headers in those metapackages.Enabled installation of mlnx-ofa_kernel package to /bin/python3 instead of / usr/bin/python3 on RHEL 8.x systems.</li>\n\t<li>All IPoIB offload packets were wrongly counted as rx_csum_complete. These packets are now identified as rx_csum_unnecessary packets.</li>\n\t<li>mlx5dv_dr_rule_destroy segmentation fault could happen in rare cases with multiple rules on the same matcher with a different number of actions. This could happen after reusing an already deleted rule memory with less actions.</li>\n\t<li>An issue of moving to SwitchDev mode after configuring DSCP (Differentiated Service Code Point).</li>\n\t<li>Global traffic class configuration did not take effect on DC QPs (Dynamically Connected Queue Pairs).</li>\n\t<li>ib_send_bw traffic frequently dropped to zero when RDMA CM was used, because of incorrect&nbsp;min_rnr_timer setting on the responder side. The min_rnr_timer setting is now aligned with the setting in non-RDMA CM cases.</li>\n\t<li>Traffic did not pass over VFs with VST QinQ feature is enabled.</li>\n\t<li>When traffic was sent over Geneve VLAN with Tx VLAN offload enabled and TSO (TCP Segmentation Offload)&nbsp;or Tx csum enabled, traffic could be dropped and not sent to the wire.</li>\n\t<li>An issue that caused the firmware to restart upon installing mlnxofed-dpdk-upstream-libs package manually.</li>\n\t<li>Bad utility paths in rdma-core &quot;dracut&quot; hooks on SLES systems, which used to result in the following errors when running &quot;dracut&quot; with the &quot;--add rdma&quot; option. dracut-install:\n\t<ul>\n\t\t<li>ERROR: installing &lsquo;/usr/libexec/mlx4-setup.sh&rsquo; dracut: /usr/lib/dracut/dracut-install -D /var/tmp/dracut.UdCOSJ/ initramfs /usr/libexec/mlx4-setup.sh dracut-install: ERROR: installing &lsquo;/usr/libexec/rdma-set-sriov-vf&rsquo; dracut: /usr/lib/dracut/dracut-install -D /var/tmp/dracut.UdCOSJ/ initramfs /usr/libexec/rdma-set-sriov-vf</li>\n\t</ul>\n\t</li>\n\t<li>Traffic class value was not updated in DCT when set via sysfs.</li>\n\t<li>A doorbell loss issue on AMD platforms with Secure Memory Encryption (SME).</li>\n\t<li>Registering memory using mlx5dv_devx_umem_reg while forking. Without this fix, applications which use fork() or similar syscalls while using a memory registered with umem_reg could hang due to incorrect physical page mapping. This fix requires setting the IBV_FORK_SAFE environment variable.</li>\n\t<li>When&nbsp;unbinding the device resulted in the following message being printed to the dmesg: &quot;failed to disable DC tracer&quot;</li>\n\t<li>Content of file /sys/class/net//statistics/ multicast might have been out of date and might have displayed values lower than the real values.</li>\n\t<li>ERSPAN (Encapsulated Remote SPAN) protocol was available only when turning off Tx checksum offload.</li>\n\t<li>A udev script issue which caused non-mellanox devices to be renamed.</li>\n\t<li>Missing representor statistics when using ifconfig.</li>\n\t<li>Fixed wrong value of skb mark of received packets on representors.</li>\n\t<li>An issue which caused second port representors to be named as first port representors.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Changes and new features in HPE Mellanox RoCE driver&nbsp;version 5.3:</strong></p>\n\n<p><strong>For ConnectX-5 Adapters and above:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>CQE compression support for Rx multi-strides packets.</li>\n\t\t<li>Configuring QoS on a single QP or on a group of QPs.</li>\n\t\t<li>Encap/decap hardware offload of IPv4 traffic over MPLS-over-UDP. This can be used in networks with MPLS routers to achieve more efficient routing.</li>\n\t\t<li>Connection tracking rules on VFs to forward traffic from one VF to the other.</li>\n\t\t<li>Offloading sFlow sampling rules.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For ConnectX-5 Adapters and ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>A locking mechanism to enable parallel insertion of rules into the software steering using the mlx5dv_dr API. The parallel insertion improves the insertion rate and takes place when adding Rx and Tx rules via the FDB domain.</li>\n\t\t<li>Option to match mlx5dv_dr API on Geneve tunnel using a dynamic flex parser. The option header consists of class, type, length and data. The parser should be configured using devx command, after which a rule can be created to match on parser ID and data.</li>\n\t\t<li>Geneve tunneling offload, including matching on extension header.</li>\n\t\t<li>Parallel insertion and deletion of offloaded rules using multiple&nbsp;OVS threads.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>[Beta] Modify GTP-U TEID. This support requires flex parser&nbsp;configuration.</li>\n\t\t<li>[Beta] Improved performance of OVS Connection Tracking flows by&nbsp;enabling the merge of the multi-table flow matches and actions into one joint flow.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Dx Adapters and above:</strong></p>\n\n<p>Added support for the following features:</p>\n\n<ul>\n\t<li>Transmitted packet timestamping accuracy can be improved when using a timestamp generated at the port level instead of a timestamp generated upon CQE creation. Tx port time-stamping better reflects the actual time of a packet&#39;s transmission. This feature is disabled by default. The feature can be enabled or disabled using the following command. ethtool --set-priv-flags tx_port_ts on / off.</li>\n\t<li>Offloading tunnel rules when the source interface is VF (in addition to uplink) in the Hypervisor.</li>\n\t<li>Using Mirroring Offload with Connection Tracking.</li>\n\t<li>ASO flow meter using the mlx5dv_dr API, which allows for monitoring the packet rate for specific flows. When a packet hits a flow that is connected to a flow meter, the rate of packets through this meter is evaluated, and the packet is marked with a color copied into one of the C registers, according to the current rate compared to the reference rate.</li>\n\t<li>ASO first hit using the mlx5dv_dr API, which allows for tracking rule hits by packets. When a packet hits a rule with the ASO first hit action, a flag is set indicating this event, and the original value of the flag is copied to one of the C registers.</li>\n\t<li>mlx5dv_dr API support for matching on a new field &quot;gtpu_first_ext_dw_0&quot;. This field enables packet filtering based on the GTP-U first extension header (first dword only). To enable parsing of tunnel GTP-U extension header, run the following command. ./cloud_fw_reset.py FLEX_PARSER_PROFILE_ENABLE=3.</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Lx Adapters and above:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>IPsec full offload support for extended sequence number, replay protection window and lifetime packet limit.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;All HCA&#39;s:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>New query GID API that allows for querying a single GID entry by its port and GID index, or querying for all GID tables of a specific device. This API works over ioctl instead of sysfs, which accelerates the querying process.</li>\n\t\t<li>Performing multi-host firmware reset in order to upgrade the device firmware. Firmware reset loads the new firmware in case it was burnt on the flash and was pending activation, and reload.</li>\n\t\t<li>[Alpha] Firmware live patching in the driver. Live patching updates the firmware without the need to perform firmware reset. However, it can only be applied in scenarios where the difference between the current and new firmware versions are minor, which is decided upon by the firmware itself.</li>\n\t\t<li>devlink tool for performing firmware reset in order to upgrade the device firmware. Firmware reset loads the new firmware in case it was burnt on the flash and was pending activation, and reloads the current firmware image from the flash in case no new firmware was pending. For further information, please refer to the the devlink man page.</li>\n\t\t<li>A resiliency mechanism for the driver to manually poll the command event queue (EQ) in case of a command timeout. In case the resiliency mechanism finds unhandled event queue entry (EQE) due to a lost interrupt, the driver will handle it, after which the command interface returns to a healthy state.</li>\n\t\t<li>Setting a sniffer private flag is deprecated and no longer required. In order to capture offloaded/RoCE traffic, tcpdump can now be run on the RDMA device.</li>\n\t\t<li>Added per-port reporters to devlink health to manage per-port health activities. Users can now access the devlink port reporters by specifying the port index in addition to the device devlink name through the devlink health commands API. This update was first introduced in iproute2 v5.8. As part of this feature, mlx5e Tx and Rx reporters are now redefined as devlink port reporters. For examples, please see devlink-health manpage</li>\n\t\t<li>Optimized memory consumption of memory registration in huge page systems. As an example, in a 2MB huge page system, 600 MB would be saved for 100 GB memory registration.</li>\n\t\t<li>mlx5dv API to modify the configured UDP source port for RoCE packets of a given RC/UC QP when QP is in RTS state.</li>\n\t\t<li>Accelerating Tx datapath by saving PCI bandwidth and CPU utilization. The savings are achieved by aggregating multiple packets into a single WQE. The feature is driven by xmit_more for certain traffic types, such as UDP.</li>\n\t</ul>\n\t</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 5.3:</strong></p>\n\n<ul>\n\t<li>Clearing min_rate on all SR-IOV legacy VFs after setting min_rate to at least one of the VFs did not disable QoS min_rate.</li>\n\t<li>An empty /usr/src/mlnx-ofa_kernel/default is now no longer created.</li>\n\t<li>An issue where installing packages through a repository failed after generation of metapackages using --add-kernel-support. The failure occurred due to excessive and incorrect Obsolete headers in those metapackages.Enabled installation of mlnx-ofa_kernel package to /bin/python3 instead of / usr/bin/python3 on RHEL 8.x systems.</li>\n\t<li>All IPoIB offload packets were wrongly counted as rx_csum_complete. These packets are now identified as rx_csum_unnecessary packets.</li>\n\t<li>mlx5dv_dr_rule_destroy segmentation fault could happen in rare cases with multiple rules on the same matcher with a different number of actions. This could happen after reusing an already deleted rule memory with less actions.</li>\n\t<li>An issue of moving to SwitchDev mode after configuring DSCP (Differentiated Service Code Point).</li>\n\t<li>Global traffic class configuration did not take effect on DC QPs (Dynamically Connected Queue Pairs).</li>\n\t<li>ib_send_bw traffic frequently dropped to zero when RDMA CM was used, because of incorrect&nbsp;min_rnr_timer setting on the responder side. The min_rnr_timer setting is now aligned with the setting in non-RDMA CM cases.</li>\n\t<li>Traffic did not pass over VFs with VST QinQ feature is enabled.</li>\n\t<li>When traffic was sent over Geneve VLAN with Tx VLAN offload enabled and TSO (TCP Segmentation Offload)&nbsp;or Tx csum enabled, traffic could be dropped and not sent to the wire.</li>\n\t<li>An issue that caused the firmware to restart upon installing mlnxofed-dpdk-upstream-libs package manually.</li>\n\t<li>Bad utility paths in rdma-core &quot;dracut&quot; hooks on SLES systems, which used to result in the following errors when running &quot;dracut&quot; with the &quot;--add rdma&quot; option. dracut-install:\n\t<ul>\n\t\t<li>ERROR: installing &lsquo;/usr/libexec/mlx4-setup.sh&rsquo; dracut: /usr/lib/dracut/dracut-install -D /var/tmp/dracut.UdCOSJ/ initramfs /usr/libexec/mlx4-setup.sh dracut-install: ERROR: installing &lsquo;/usr/libexec/rdma-set-sriov-vf&rsquo; dracut: /usr/lib/dracut/dracut-install -D /var/tmp/dracut.UdCOSJ/ initramfs /usr/libexec/rdma-set-sriov-vf</li>\n\t</ul>\n\t</li>\n\t<li>Traffic class value was not updated in DCT when set via sysfs.</li>\n\t<li>A doorbell loss issue on AMD platforms with Secure Memory Encryption (SME).</li>\n\t<li>Registering memory using mlx5dv_devx_umem_reg while forking. Without this fix, applications which use fork() or similar syscalls while using a memory registered with umem_reg could hang due to incorrect physical page mapping. This fix requires setting the IBV_FORK_SAFE environment variable.</li>\n\t<li>When&nbsp;unbinding the device resulted in the following message being printed to the dmesg: &quot;failed to disable DC tracer&quot;</li>\n\t<li>Content of file /sys/class/net//statistics/ multicast might have been out of date and might have displayed values lower than the real values.</li>\n\t<li>ERSPAN (Encapsulated Remote SPAN) protocol was available only when turning off Tx checksum offload.</li>\n\t<li>A udev script issue which caused non-mellanox devices to be renamed.</li>\n\t<li>Missing representor statistics when using ifconfig.</li>\n\t<li>Fixed wrong value of skb mark of received packets on representors.</li>\n\t<li>An issue which caused second port representors to be named as first port representors.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"kmod-mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JXLBA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WpariscASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a584c4241","Version":"HPD2"},{"DeviceName":"MB018000JXLAU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WpariscASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a584c4155","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB016000JXLBA and MB018000JXLAU"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online HDD/SSD&nbsp;Flash Component for VMware ESXi - MB016000JXLBA and MB018000JXLAU&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>VENDOR IDENTIFICATION field changed from &ldquo;HP&rdquo; to &ldquo;HPE&rdquo; and Reliability improvements.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"20359631","datemodified":"2021-08-30T05:55:43","file_list":["/CP049256_BUILD_1.data","/CP049256.vmexe","/CP049256.vmexe64","/CP049256.vmfile","/CP049256_VMw.zip","/CP049256.xml","/payload.json","/CP049256_VMw.zip/index.xml","/CP049256_VMw.zip/vendor-index.xml","/CP049256_VMw.zip/metadata.zip","/CP049256_VMw.zip/vib20/CP049256/HPE_bootbank_CP049256_HPD2.1-7.0.0.15843807.vib","/CP049256_VMw.zip/metadata.zip/vendor-index.xml","/CP049256_VMw.zip/metadata.zip/vmware.xml","/CP049256_VMw.zip/metadata.zip/vibs/CP049256-1448076509749438707.xml","/CP049256_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049256_HPD2.1-7.0.0.15843807.xml"],"md5sum":"f37b41fa3bd970a6b8e051b691e48bcb","name":"CP049256.zip","release":"2021-08-30T05:51:24","revision":"0","sha1sum":"d0c61fdcae830a126b37cb8ae2c6b0579723a3c1","size":"19MB","target_guids":["4d2340a5-3042-3631-3030-304a584c4241","4d2340a5-3042-3831-3030-304a584c4155"],"type_of_change":"1","version":"HPD2","vib_list":[{"name":"CP049256","version":"HPD2.1-7.0.0.15843807"}]}],"id":{"product":"97b8f64d84c04c1a9c4048cae29b4037","version":"889aa37fe86b45a4b6a478e53c7ca87d"},"installation":{"command":"CP041025.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB016000JXLBA and MB018000JXLAU Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB016000JXLBA","target_guid":"4d2340a5-3042-3631-3030-304a584c4241","type":"sas"},{"id":"MB018000JXLAU","target_guid":"4d2340a5-3042-3831-3030-304a584c4155","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-11T18:25:05","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>VENDOR IDENTIFICATION field changed from &ldquo;HP&rdquo; to &ldquo;HPE&rdquo; and Reliability improvements.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB018000JXLAU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB016000JXLBA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWTFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG07scHPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57544644","Version":"HPD8"},{"DeviceName":"MB012000JWTFC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG07scHPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57544643","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB014000JWTFD and MB012000JWTFC"},{"lang":"ja","x_late":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB014000JWTFDおよびMB012000JWTFC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB014000JWTFD and MB012000JWTFC Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>This firmware release provides additional protection against command timeouts.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3049624","datemodified":"2021-08-13T12:13:40","file_list":["cp049123.xml","cpqsetup.exe","payload.json","setup.dll","TAMG07scHPD8.REL"],"md5sum":"e8361dd41777d06872165979188fe0dc","name":"cp049123.exe","release":"2021-08-13T12:06:18","revision":"0","sha1sum":"41f035d8b75f57f5564e15d04ae907a4375ce84f","size":"2MB","target_guids":["4d2340a5-3042-3431-3030-304a57544644","4d2340a5-3042-3231-3030-304a57544643"],"type_of_change":"1","version":"HPD8"}],"id":{"product":"b24f5415c77d43548ef3f4466312e507","version":"53ad7472344e43239ac3d54794534a73"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB014000JWTFD and MB012000JWTFC Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB014000JWTFDおよびMB012000JWTFCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB014000JWTFD","target_guid":"4d2340a5-3042-3431-3030-304a57544644","type":"sas"},{"id":"MB012000JWTFC","target_guid":"4d2340a5-3042-3231-3030-304a57544643","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T15:24:36","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This firmware release provides additional protection against command timeouts.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This firmware release provides additional protection against command timeouts.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB014000JWTFD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB012000JWTFC","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the HPE Apollo 45xx Gen9 Backplane Expanders"},{"lang":"cn","x_late":"此智能组件为HPE Apollo 45xx Gen9背板扩展卡提供固件"},{"lang":"tw","x_late":"此智慧型元件提供適用於 HPE Apollo 45xx Gen9 背板擴充卡的韌體"},{"lang":"ko","x_late":"이 스마트 구성요소가 HPE Apollo 45xx Gen9 백플레인 익스팬더의 펌웨어 제공"},{"lang":"ja","x_late":"このSmartコンポーネントは、HPE Apollo 45xx Gen9バックプレーンエキスパンダーのファームウェアを提供します"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for Windows &ndash; HPE Apollo 45xx Gen9 Backplane Expander Firmware</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;2.51<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 2.50<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;2.50<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;None</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Drive may show up&nbsp;missing after a system reboot.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"},{"lang":"ja","x_late":"<p><strong>提供名：</strong><br />\n     オンラインROMフラッシュコンポーネントfor VMware Windows - HPE Apollo 45xx Gen9バックプレーンエキスパンダーファームウェア</p>\n\n<p><strong>リリースバージョンおよび/または日付:</strong><br />\n     2.51<br />\n<br />\n<strong>最新の推奨またはクリティカルバージョン:</strong><br />\n     2.50<br />\n<br />\n<strong>前のファームウェアバージョン:</strong><br />\n     2.50<br />\n<br />\n<strong>ファームウェアの関連性:</strong><br />\n     なし        <br />\n<br />\n<strong>改善点/新しい機能：</strong></p>\n\n<ul>\n\t<li> なし\n        </li>\n</ul>\n\n<p><strong>修正された問題点：</strong></p>\n\n<ul>\n\t<li>システムの再起動後にドライブが表示されない場合があります。</li>\n</ul>\n\n<p><strong>既知の問題点:</strong><br />\n     なし        </p>\n"}],"files":[{"bytes":"3673256","datemodified":"2020-03-16T19:17:54","file_list":["cp043498.xml","cpqsetup.exe","firmware-Release-2.51-build-000.bin.fw","setup.dll"],"md5sum":"7bb0f37f5d2a1e01ea2bbc2dec049ad3","name":"cp043498.exe","release":"2020-03-16T00:00:00","revision":"1","sha1sum":"1eeefe8a6bc3fde18ca31c78774b777f62e99018","size":"3MB","target_guids":[],"type_of_change":"1","version":"2.51"}],"id":{"product":"438f20c90cc14939afac73df8f31d682","version":"d1679a346e174ee795bff90db8957480"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><u>Please&nbsp;un-plug and re-plug the power cord to the server for firmware upgrade from version 1.03&nbsp;or earlier to take effect.</u></p>\n\n<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a></strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li>\n\t<li>Run launch_sum.bat script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><u>バージョン1.03以前からのファームウェアアップグレードを有効にするために、サーバーの電源コードを1度抜いて、再度挿してください。</u></p>\n\n<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>HP Smart Update Managerを使用するには、\n          </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant:</a>から以下の手順に従ってください</strong></p>\n\n<ul>\n\t<li>ディレクトリ\\SPP20xxxxx\\hp\\swpackagesにアップデートに必要なファームウェアをコピーします。</li>\n\t<li>ISOのルートにある launch_hpsum.sh スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n\n<p> </p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows (x64) - HPE Apollo 45xx Gen9 Backplane Expander Firmware "},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows (x64) - HPE Apollo 45xx Gen9バックプレーンエキスパンダーファームウェア "}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-05-02T14:37:34","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Drive may show up&nbsp;missing after a system reboot.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Drive may show up&nbsp;missing after a system reboot.</p>\n\n<p>Please reference Customer Advisory a00098241en_us</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"Carbondale14","value":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"key":"Carbondale14","value":"<p>HPE Apollo 4520 Gen9 Chassis</p>\n"},{"key":"Carbondale14","value":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>\n"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"}],"sw_keys":[{"name":"HP Apollo 4530","sw_key_expectedpath":"firmware:sd:sasexpander"},{"name":"HP Apollo 4520","sw_key_expectedpath":"firmware:sd:sasexpander"},{"name":"HP Apollo 4510","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900374","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware and boot BIOS of Emulex Mezzanine Fibre channel host bus adapters."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"3932160","datemodified":"2021-08-26T11:18:35","file_list":["cp048580.xml","cpqsetup.exe","elxflashStandalone-windows-12.8.528.12-1/boot/","elxflashStandalone-windows-12.8.528.12-1/firmware/","elxflashStandalone-windows-12.8.528.12-1/firmware/A12852812.grp","elxflashStandalone-windows-12.8.528.12-1/win/","elxflashStandalone-windows-12.8.528.12-1/win/elxflash.bat","elxflashStandalone-windows-12.8.528.12-1/win/winlpcfg.bat","elxflashStandalone-windows-12.8.528.12-1/win/x64/","elxflashStandalone-windows-12.8.528.12-1/win/x64/boot/","elxflashStandalone-windows-12.8.528.12-1/win/x64/elxflash.exe","elxflashStandalone-windows-12.8.528.12-1/win/x64/ElxLpCfgSvcMsg.dll","elxflashStandalone-windows-12.8.528.12-1/win/x64/firmware/","elxflashStandalone-windows-12.8.528.12-1/win/x64/fwmatrix.txt","elxflashStandalone-windows-12.8.528.12-1/win/x64/libdfc.dll","elxflashStandalone-windows-12.8.528.12-1/win/x64/RM.INI","elxflashStandalone-windows-12.8.528.12-1/win/x64/WinLpCfg.exe","fwmatrix.txt","hpe_fw_matrix.xml","installer.dll","payload.json","readme.txt","elxflashStandalone-windows-12.8.528.12-1/win/x64/readme.txt","reference.xml"],"md5sum":"cbd051005be5ace628d9addf12fed8db","name":"cp048580.exe","release":"2021-08-26T11:03:43","revision":"0","sha1sum":"63f1f0b9ba528aeb802864ce411ccfb2b04247be","size":"3MB","target_guids":[],"type_of_change":"1","version":"2021.10.01"}],"id":{"product":"192e37447c1d4e65a0dfd934caa87c86","version":"9ae0a9ef1bd441f185ca37d696664453"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory.<br />\nThe downloaded file is a self-extracting executable with a filename based on the Component Number.<br />\nFrom that drive and directory, execute the downloaded file.<br />\n<br />\nClick the &quot;Install&quot; button to proceed with the installation.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Mezzanine Fibre Channel Host Bus Adapters for Microsoft Windows Server 2016/2019 x64"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T09:15:46","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This Firmware package contains following firmware versions:&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 16Gb LPe1605 Fibre Channel Host Bus Adapter for BladeSystem c-Class</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>12.8.528.12</td>\n\t\t\t<td>12.8.528.12</td>\n\t\t\t<td>12.8.528.10</td>\n\t\t\t<td>12.8.502.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"emulex","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000JEFNC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRASD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a45464e43","Version":"HPD9"},{"DeviceName":"MB6000JEFND","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRASD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a45464e44","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB4000JEFNC and MB6000JEFND"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MB4000JEFNCおよびMB6000JEFND"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB4000JEFNC and MB6000JEFND Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5528574","datemodified":"2021-07-23T07:20:00","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-af802bb412-HPD9-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-af802bb412-HPD9-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-af802bb412-HPD9-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-af802bb412-HPD9-8.1/CP048163.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-af802bb412-HPD9-8.1/SMKRASD9.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-af802bb412-HPD9-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-af802bb412-HPD9-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-af802bb412-HPD9-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-af802bb412-HPD9-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048163.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048163.scexe"],"md5sum":"18003c8a6c54038c83157ef607b17c8b","name":"firmware-hdd-af802bb412-HPD9-8.1.x86_64.rpm","release":"2021-07-23T07:08:14","revision":"0","sha1sum":"21628c63d4f00963a1a95fedd36884be77973595","size":"5MB","target_guids":["002340a5-4d00-3442-3030-304a45464e43","002340a5-4d00-3642-3030-304a45464e44"],"type_of_change":"1","version":"HPD9"}],"id":{"product":"c89e43e26231479bbdf6b9f0111deee2","version":"15e01943e6134b8a936804ec42e1f124"},"installation":{"command":"CP040274.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB4000JEFNC and MB6000JEFND Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB4000JEFNCおよびMB6000JEFNDドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB4000JEFNC","target_guid":"002340a5-4d00-3442-3030-304a45464e43","type":"sas"},{"id":"MB6000JEFND","target_guid":"002340a5-4d00-3642-3030-304a45464e44","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T19:17:36","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JEFNC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB6000JEFND","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]},{"key":"7800374","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"en","x_late":"This package contains utilities and libraries to enable HPE Storage fibre channel over Ethernet array connectivity on Red Hat Enterprise Linux 8 Server for Emulex Host Bus Adapters and Mezzanine Host Bus Adapters."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"923210","datemodified":"2021-08-27T06:15:35","file_list":["./opt/broadcom/rhel8/x86_64/lib64/libbrcmdfc.so","./opt/broadcom/rhel8/x86_64/lib64/libbrcmdfc.so.12","./opt/broadcom/rhel8/x86_64/lib64/libbrcmdfc.so.12.0.1329","./opt/broadcom/rhel8/x86_64/lib64/libbrcmemsdm.so","./opt/broadcom/rhel8/x86_64/lib64/libbrcmhbaapi.so","./usr/lib/.build-id","./usr/lib/.build-id/75","./usr/lib/.build-id/75/7c1bf6797cbd66b05c35bb64a5d5603f67ad66","./usr/lib/.build-id/75/7c1bf6797cbd66b05c35bb64a5d5603f67ad66.1","./usr/lib/.build-id/7c","./usr/lib/.build-id/7c/1b0a41fc41e4bb166f002b7632fd98e45d938b","./usr/lib/.build-id/7c/1b0a41fc41e4bb166f002b7632fd98e45d938b.1","./usr/lib/.build-id/b1","./usr/lib/.build-id/b1/3574b27c2297ef7c922a0558dc0044a36035a8","./usr/lib/.build-id/b1/3574b27c2297ef7c922a0558dc0044a36035a8.1","./usr/lib64/libbrcmdfc.so","./usr/lib64/libbrcmdfc.so.12","./usr/lib64/libbrcmdfc.so.12.0.1329","./usr/lib64/libbrcmemsdm.so","./usr/lib64/libbrcmhbaapi.so","./usr/share/smartupdate/HPE-CNA-FC-Broadcom-Enablement-Kit/component.xml"],"md5sum":"55ca078fdecd0df8806cb4d36c298cfe","name":"HPE-CNA-FC-Broadcom-Enablement-Kit-12.0.1339.0-1.rhel8.x86_64.rpm","release":"2021-08-27T06:08:11","revision":"0","sha1sum":"50313d5dd337530e387afe1bb99f6d01de6a4c3c","size":"901KB","target_guids":[],"type_of_change":"1","version":"12.0.1339.0"}],"id":{"product":"1d5cc247bca042d1b8005497260d873b","version":"58070ebff6d24710b5209bede1040cb2"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>There has been a change to the enablement kits in this release.&nbsp; They are now vendor specific kits.&nbsp;&nbsp; It is recommended that you uninstall any previous kits prior to installation of this component.<br />\n<br />\nTo uninstall the hp-fc-enablement RPM use the following command:</p>\n\n<p>&nbsp;&nbsp; # rpm -e hp-fc-enablement-&lt;version&gt;.noarch.rpm<br />\n<br />\nTo install the hp-CNA-fc-enablement RPM use the following command:</p>\n\n<p>&nbsp;&nbsp; # rpm -ivh HP-CNA-FC-Broadcom-Enablement-Kit-&lt;version&gt;.&lt;OS&gt;.&lt;architecture&gt;.rpm<br />\n<br />\nThis version of the enablement kit does not provide the additional functionality of rebuilding the ram disk or setting driver parameters as the previous versions had done.&nbsp; Please refer to the &ldquo;Additional setup&rdquo; section of the Native Linux Device-Mapper Multipath for HPE StorageWorks Arrays reference guide for instructions on how to perform these functions.&nbsp; The reference guide is available at the following link:<br />\n&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; <a href=\"http://www.hpe.com/storage/spock/\">http://www.hpe.com/storage/spock/</a><br />\n&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex(BRCM) Fibre Channel Over Ethernet Enablement Kit for Host Bus Adapters and Mezzanine Host Bus Adapters for Red Hat Enterprise Linux 8 Server"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T11:01:09","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to version: 12.0.1339.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"}],"sw_keys":[{"name":"HPE-CNA-FC-Broadcom-Enablement-Kit","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900083","languages":[{"lang":"tw","x_late":"韌體 ─ 電源管理"},{"lang":"en","x_late":"Firmware - Power Management"},{"lang":"ko","x_late":"펌웨어 - 전원 관리"},{"lang":"ja","x_late":"ファームウェア - パワー マネジメント"},{"lang":"cn","x_late":"固件 - 电源管理"}]}],"description":[{"lang":"tw","x_late":"此元件可更新 HPE Gen9 伺服器上的進階功率限定微控制器韌體。"},{"lang":"en","x_late":"This component updates the  Advanced Power Capping Microcontroller Firmware for HPE Gen9 Servers"},{"lang":"ko","x_late":"이 구성 요소는 HPE Gen9 서버의 고급 전원 캐핑 마이크로컨트롤러 펌웨어를 업데이트합니다."},{"lang":"cn","x_late":"该组件可更新用于 HPE Gen9 服务器的高级功率封顶微控制器固件"},{"lang":"ja","x_late":"このコンポーネントは、アドバンスト消費電力上限マイクロコントローラーファームウェア for HPE Gen9サーバーをアップデートします"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"2817527","datemodified":"2021-03-16T00:39:57","file_list":["/CP047167.vmexe","/CP047167.vmexe64","/CP047167.vmfile","/CP047167.xml","/README.txt"],"md5sum":"aa353be6969c5b8b46e2739a249db9a6","name":"CP047167.zip","release":"2021-03-16T05:37:04","revision":"0","sha1sum":"c0f9dd7f8e4cdab55ae09532fe6b22d74250c99d","size":"2MB","target_guids":[],"type_of_change":"0","version":"1.0.9","vib_list":[]}],"id":{"product":"926e3abf2abf49c2929e347ad48989a8","version":"71d88fc5be0b4f3da67415ecaf19480c"},"installation":{"command":"cpqsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component requires that the CRU driver be loaded before the component can run.</p>\n\n<p>The minimum CRU version for ESXi 5.1 is 5.0.3.9.</p>\n\n<p>The minimum CRU version for ESXi 5.5 is 5.5.4.1.</p>\n\n<p>The minimum CRU version for ESXi 6.0 is 6.0.8</p>\n\n<p>The minimum CRU version for 6.5 is 6.5.8.</p>\n\n<p>The minimum CRU version for 6.7 is 6.7.10.<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>SPP Offline mode boots a special Linux OS environment, thus the Linux Components are used, not the VMware Components</li>\n</ul>\n\n<p><br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Download the appropriate SPP</li>\n\t<li>Add the component to the SPP</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run SUM</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps to complete the firmware update</li>\n\t<li>Refer to the SPP documentation for detailed instructions at:&nbsp; <a href=\"http://www.hp.com/go/spp\">www.hpe.com/go/spp</a></li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Component ( CPxxxxxx.zip) in a temporary directory</li>\n\t<li>From the same directory, unzip the Component:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>To perform the standalone installation, execute the command:<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>Follow the directions given by the Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system for the firmware update to take effect</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、実行する前にCRUドライバーがロードされている必要があります。</p>\n\n<p>ESXi 5.1の最小CRUバージョンは5.0.3.9です。</p>\n\n<p>ESXi 5.5の最小CRUバージョンは5.5.4.1です。</p>\n\n<p>ESXi 6.0の最小CRUバージョンは6.0.8です。</p>\n\n<p>6.5の最小CRUバージョンは6.5.8です。</p>\n\n<p>6.7の最小CRUバージョンは6.7.10です。<br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMwareコンポーネントではなく、Linuxコンポーネントが用いられます</li>\n</ul>\n\n<p><br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします</li>\n\t<li>SPPにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします</li>\n\t<li>SUMを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います</li>\n\t<li>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください: <a href=\"http://www.hp.com/go/spp\">www.hpe.com/go/spp</a></li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>コンポーネント (CPxxxxxx.zip)を一時ディレクトリに置きます</li>\n\t<li>同じディレクトリからコンポーネントをunzipします:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>スタンドアロンのインストールを行うために、次のコマンドを実行します：<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>コンポーネントの指示に従います</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n\t<li>システムを再起動し、ファームウェアのアップデートを有効にします</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 VMware ESXi 的 ROM 線上更新 - 適用於 HPE Gen9 伺服器的進階功率限定微控制器韌體"},{"lang":"en","x_late":"Online ROM Flash for VMware ESXi - Advanced Power Capping Microcontroller Firmware for HPE Gen9 Servers"},{"lang":"ko","x_late":"VMware ESXi용 온라인 ROM 플래시 - HPE Gen9 서버의 고급 전원 캐핑 마이크로컨트롤러 펌웨어"},{"lang":"cn","x_late":"用于 VMware ESXi 的在线 ROM 刷新 - 用于 HPE Gen9 服务器的高级功率封顶微控制器固件"},{"lang":"ja","x_late":"オンラインROMフラッシュ for VMware ESXi - アドバンスト消費電力上限マイクロコントローラーファームウェア for HPE Gen9サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"5","minor":"1","name":"VMware vSphere 5.1","platform":"vmware_esx_server","sr":"OEM"},{"major":"5","minor":"5","name":"VMware vSphere 5.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-16T05:32:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>Ver. 1.0.9(J) contains updates to the component packaging and is functionally equivalent to ver. 1.0.9. It is not necessary to upgrade with Revision J&nbsp;if a previous component Revision was used to upgrade the firmware to version 1.0.9.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>Addresses an issue in which the minimum power capping value was incorrectly being calculated on certain systems. This fix increases the accuracy of the minimum capping value set during POST.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>Ver. 1.0.9(K) contains updates to the component packaging and is functionally equivalent to ver. 1.0.9. It is not necessary to upgrade with Revision K if a previous component Revision was used to upgrade the firmware to version 1.0.9.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>Addresses an issue in which the minimum power capping value was incorrectly being calculated on certain systems. This fix increases the accuracy of the minimum capping value set during POST.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U19","value":"HPE ProLiant XL420 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"}],"sw_keys":[{"name":"PowerPIC-Gen9","sw_key_expectedpath":"firmware:sd:powerpic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JWKGN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAeAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574b474e","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB006000JWKGN"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB006000JWKGN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB006000JWKGN Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD1<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"6148374","datemodified":"2021-07-23T08:14:10","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-2.1/CP048132.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-2.1/HVLAeAsseFD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048132.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048132.scexe"],"md5sum":"388a6c1c1559ca6d9b690e42c757695a","name":"firmware-hdd-a886842a99-HPD2-2.1.x86_64.rpm","release":"2021-07-23T08:01:13","revision":"0","sha1sum":"a067c36af3386ff6f1fba7859d3fe9bf92663469","size":"5MB","target_guids":["4d2340a5-3042-3630-3030-304a574b474e"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"9ea83d5d4cdf449690664479d7c8538a","version":"1ac367c3c29041abb54079d02fb76138"},"installation":{"command":"CP041488.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB006000JWKGN Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) -  MB006000JWKGN ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB006000JWKGN","target_guid":"4d2340a5-3042-3630-3030-304a574b474e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-26T11:20:15","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000JWKGN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE 12Gb SAS Expander Card","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"firmware-Signed-5.10-build-000.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","Version":"5.10"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"Online Smart Component which upgrades the enclosure firmware on HPE ProLiant Gen9 expanders"},{"lang":"cn","x_late":"升级HPE ProLiant Gen9扩展卡上机柜固件的在线智能组件"},{"lang":"tw","x_late":"可升級 HPE ProLiant Gen9 擴充卡上機櫃韌體的線上智慧型元件"},{"lang":"ko","x_late":"HPE Proliant Gen9 Expander에서 인클로저 펌웨어를 업그레이드하는 온라인 스마트 구성 요소"},{"lang":"ja","x_late":"HPE ProLiant Gen9エキスパンダーのエンクロージャーファームウェアをアップグレードするオンラインSmartコンポーネントです"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for VMware ESXi &ndash; HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;5.10<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;5.09<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; 4.22(A)<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>N/A</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Valid flag is always set to true initially so that CRC check can be performed on initstring partition and test if it is really valid.</li>\n\t<li>Move Smart Carrier Authentication to later in the boot process and move the Exception Dumper task to earlier in the process in order to support Winbond alternative Flash</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>提供名：</strong><br />\n     オンラインROMフラッシュコンポーネントfor VMware ESXi - HPE 12 Gb/s SASエキスパンダーファームウェアfor HPE SmartアレイコントローラーおよびHPE HBAコントローラー</p>\n\n<p><strong>リリースバージョンおよび/または日付:</strong><br />\n     5.10<br />\n<br />\n<strong>最新の推奨またはクリティカルバージョン：</strong><br />\n     5.09<br />\n<br />\n<strong>以前のファームウェアバージョン：</strong><br />\n     4.22(A)<br />\n<br />\n<strong>ファームウェアmoの関連性:</strong><br />\n     なし  <br />\n<br />\n<strong>改善点/新しい機能：</strong></p>\n\n<ul>\n\t<li>N/A    </li>\n</ul>\n\n<p><strong>修正された問題：</strong></p>\n\n<ul>\n\t<li>有効なフラグは最初は常にtrueに設定されているため、initstringパーティションでCRCチェックを実行し、それが本当に有効かどうかをテストできます。</li>\n\t<li>Winbondの代替フラッシュをサポートするために、スマートキャリア認証をブートプロセスの後半に移動し、Exception Dumperタスクをプロセスの前半に移動してください</li>\n</ul>\n\n<p><strong>既知の問題点:</strong><br />\n     なし        </p>\n\n<p> </p>\n"}],"files":[{"bytes":"30313071","datemodified":"2021-08-16T14:45:54","file_list":["/CP049281_BUILD_2.data","/CP049281.vmexe","/CP049281.vmexe64","/CP049281.vmfile","/CP049281_VMw.zip","/CP049281.xml","/payload.json","/CP049281_VMw.zip/index.xml","/CP049281_VMw.zip/vendor-index.xml","/CP049281_VMw.zip/metadata.zip","/CP049281_VMw.zip/vib20/CP049281/HPE_bootbank_CP049281_5.10.2-7.0.0.15843807.vib","/CP049281_VMw.zip/metadata.zip/vendor-index.xml","/CP049281_VMw.zip/metadata.zip/vmware.xml","/CP049281_VMw.zip/metadata.zip/vibs/CP049281--5876029568697298306.xml","/CP049281_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049281_5.10.2-7.0.0.15843807.xml"],"md5sum":"3193b1195ed0d476cf042657b0bcf3f5","name":"CP049281.zip","release":"2021-09-06T00:00:00","revision":"1","sha1sum":"8c326b6f82f0a943539d0a3e7c5fc9d24d03f3cc","size":"28MB","target_guids":["b99dfb74-f0bc-464f-b418-cd18c097d8f0"],"type_of_change":"1","version":"5.10","vib_list":[{"name":"CP049281","version":"5.10.2-7.0.0.15843807"}]}],"id":{"product":"1655bc494b334729864d929c38544849","version":"7133558eb8ef4059813b2a988d710189"},"installation":{"command":"CP049281.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><u>Power cycle / cold reboot is required if firmware is upgraded from version 1.31 or earlier.</u></p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp; &nbsp; &nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n<br />\n<strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n\t<li>Reboot your system, for the firmware update to take effect.</li>\n</ul>\n\n<p><strong>Additional information to execute VIB file.</strong></p>\n\n<p><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><u>ファームウェアがバージョン1.31またはそれ以前からアップグレードされた場合には、電源再投入/コールドリブートが必要です。</u></p>\n\n<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n      リモートオンライン：</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>HP Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n<br />\n<strong>HPE Insight Control for vCenterを使用するには、以下の手順に従ってください:</strong></p>\n\n<ul>\n\t<li>vSphereクライアントにログインします。</li>\n\t<li>インベントリツリーのサーバーまたはクラスターを選択します。</li>\n\t<li>HPE Insight Managementタブをクリックします。</li>\n\t<li>HP Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします。</li>\n\t<li>コマンドを使用してCPXXXXXX.vmexeが実行可能であることを確認します:</li>\n</ul>\n\n<p>             chmod +x CPXXXXXX.vmexe    </p>\n\n<ul>\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPXXXXXX.vmexe</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n\t<li>ファームウェアアップデートを有効にするためにシステムを再起動します。</li>\n</ul>\n\n<p><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul>\n\t<li>vibファイルのインストール：esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zip。</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除：esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul>\n\t<li>vibファイルの削除: esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zip。</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります:rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><フルパス>は、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware ESXi - HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor VMware ESXi - HPE 12 Gb/s SASエキスパンダーファームウェアfor HPE SmartアレイコントローラーおよびHPE HBAコントローラー"}],"prerequisites":{"required_diskspace":{"size_kb":"12000"},"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-10-07T07:19:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>To make Valid flag is always set to true initially so that CRC check can be performed on initstring partition and test if it is really valid.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Valid flag is always set to true initially so that CRC check can be performed on initstring partition and test if it is really valid.</li>\n\t<li>Move Smart Carrier Authentication to later in the boot process and move the Exception Dumper task to earlier in the process in order to support Winbond alternative Flash</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"12G SAS Exp Card","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK0120GFDKE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3132-304746444b45","Version":"HPG1"},{"DeviceName":"VK0240GFDKF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3234-304746444b46","Version":"HPG1"},{"DeviceName":"VK0480GFDKH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3438-304746444b48","Version":"HPG1"},{"DeviceName":"VK0960GFDKK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3936-304746444b4b","Version":"HPG1"},{"DeviceName":"VK1920GFDKL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314b-3932-304746444b4c","Version":"HPG1"},{"DeviceName":"VK3840GFDKN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-334b-3834-304746444b4e","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK0120GFDKE, VK0240GFDKF, VK0480GFDKH, VK0960GFDKK, VK1920GFDKL and VK3840GFDKN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK0120GFDKE, VK0240GFDKF, VK0480GFDKH, VK0960GFDKK, VK1920GFDKL, and VK3840GFDKN Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"15740617","datemodified":"2021-08-27T10:43:49","file_list":["/CP048412_BUILD_3.data","/CP048412.vmexe","/CP048412.vmexe64","/CP048412.vmfile","/CP048412_VMw.zip","/CP048412.xml","/payload.json","/CP048412_VMw.zip/index.xml","/CP048412_VMw.zip/vendor-index.xml","/CP048412_VMw.zip/metadata.zip","/CP048412_VMw.zip/vib20/CP048412/HPE_bootbank_CP048412_HPG1.3-7.0.0.15843807.vib","/CP048412_VMw.zip/metadata.zip/vendor-index.xml","/CP048412_VMw.zip/metadata.zip/vmware.xml","/CP048412_VMw.zip/metadata.zip/vibs/CP048412--5067656484060346386.xml","/CP048412_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048412_HPG1.3-7.0.0.15843807.xml"],"md5sum":"a16ad0d4433ce55a616270e9f7cd0497","name":"CP048412.zip","release":"2021-08-27T10:38:53","revision":"0","sha1sum":"8e9ee152dc26da53ef6d77ba77660f17db058ff5","size":"15MB","target_guids":["002340a5-5600-304b-3132-304746444b45","002340a5-5600-304b-3234-304746444b46","002340a5-5600-304b-3438-304746444b48","002340a5-5600-304b-3936-304746444b4b","002340a5-5600-314b-3932-304746444b4c","002340a5-5600-334b-3834-304746444b4e"],"type_of_change":"1","version":"HPG1","vib_list":[{"name":"CP048412","version":"HPG1.3-7.0.0.15843807"}]}],"id":{"product":"d568c20f8443428c99b5421748aa1148","version":"a895abfb168648d3baf79086f736240e"},"installation":{"command":"CP042540.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK0120GFDKE, VK0240GFDKF, VK0480GFDKH, VK0960GFDKK, VK1920GFDKL, and VK3840GFDKN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VK0120GFDKE、VK0240GFDKF、VK0480GFDKH、VK0960GFDKK、VK1920GFDKL、およびVK3840GFDKNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VK0120GFDKE","target_guid":"002340a5-5600-304b-3132-304746444b45","type":"sata"},{"id":"VK1920GFDKL","target_guid":"002340a5-5600-314b-3932-304746444b4c","type":"sata"},{"id":"VK0240GFDKF","target_guid":"002340a5-5600-304b-3234-304746444b46","type":"sata"},{"id":"VK3840GFDKN","target_guid":"002340a5-5600-334b-3834-304746444b4e","type":"sata"},{"id":"VK0480GFDKH","target_guid":"002340a5-5600-304b-3438-304746444b48","type":"sata"},{"id":"VK0960GFDKK","target_guid":"002340a5-5600-304b-3936-304746444b4b","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T07:20:43","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK0960GFDKK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0120GFDKE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0480GFDKH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK1920GFDKL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK3840GFDKN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0240GFDKF","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"HPE QLogic Mezzanine Fibre Channel driver for VMware vSphere 6.5"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"1538532","datemodified":"2021-08-27T04:27:42","file_list":["/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip","/cp048708.xml","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/qlnativefc-2.1.101.0-1OEM.600.0.0.2768847.x86_64.vib","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/doc/README.txt","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/doc/release_note_qlnativefc_2.1.101.0-1OEM.600.0.0.2768847.txt","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/index.xml","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/vendor-index.xml","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/metadata.zip","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/vib20/qlnativefc/QLogic_bootbank_qlnativefc_2.1.101.0-1OEM.600.0.0.2768847.vib","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/metadata.zip/vmware.xml","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/metadata.zip/bulletins/VMW-ESX-6.0.0-qlnativefc-2.1.101.0.xml","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/metadata.zip/vibs/qlnativefc--7247954598143724648.xml"],"md5sum":"45be767537ff4bb1858891a44255454a","name":"cp048708.zip","release":"2021-08-27T04:26:49","revision":"0","sha1sum":"07876faecb451156a527b29369b5de524f139f80","size":"1MB","target_guids":[],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"qlnativefc","version":"2.1.101.0-1OEM.600.0.0.2768847"}]}],"id":{"product":"5eaf413328224cab9786586caa2652b3","version":"bb69348ce2bd4ec6a180e13b7918c602"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware&nbsp;vSphere Update Manager&nbsp;or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VMware&nbsp;vSphere Update Manager and the esxcli commands</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic Mezzanine Fibre Channel driver component for VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-18T06:27:08","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Made improvements to the Fabric Port Identification Number (FPIN) and Universal Storage Area Network (SAN) Congestion Mitigation(USCM) Congestion Management algorithm</li>\n\t<li>\n\t<p>Implemented the vmkmgmt Application programming Interface (API) to report Non-Volatile Memory Express (NVMe) target info and send Non-Volatile Memory Express (NVMe) pass through commands</p>\n\t</li>\n</ul>\n\n<p>Driver version 2.1.101.0</p>\n","curr_fixes_x_late":"<ul>\n\t<li>Fixed an unwanted behavior where Get Port Speed Capabilities (GPSC) failures were leading to intelligent interleaved direct memory access (IIDMA) for target being set to 1GB/s. This is described in <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00115969en_us\">Advisory: HPE Host Bus Adapters - HPE Platforms Running VMware ESXi 6.5 / 6/7 / 7.0 and Configured With Certain HPE Host Bus Adapters May Experience Severe Performance Degradation When Connected to Brocade FOS v8.0.1 (or Prior)</a></li>\n\t<li>Addressed unwanted behavior with Fabric Port Identification Number (FPIN) based congestion throttling leading to poor performance.</li>\n\t<li>Fixed an unwanted behavior where stale connection IDs could be used with Fibre Channel- Non Volatile Memory Express (FC-NVMe) traffic.</li>\n\t<li>\n\t<p>Fixed an unwanted behavior with response queue handling to avoid the problem referenced by <a href=\"https://kb.vmware.com/s/article/81721\">https://kb.vmware.com/s/article/81721</a></p>\n\t</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"qlnativefc:2.1.101.0-1OEM.600.0.0.2768847","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the drivers for HPE Intel i40ea 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Microsoft Windows Server 2019で動作しているHPE Intel i40ea 10 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1128272","datemodified":"2021-01-08T15:50:04","file_list":["cp045126.xml","cpqsetup.exe","cp_data.xml","i40ea68.cat","i40ea68.din","i40ea68.inf","i40ea68.sys","i40eamsg.dll","install.xml","nicdrvr.dll"],"md5sum":"ae896d7ebe5944d4eaaa1ce889b4318b","name":"cp045126.exe","release":"2021-01-08T15:36:06","revision":"0","sha1sum":"891e4e6b3fdcf9d650ca1eacf3c09403d2371b49","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecc6f71532"],"type_of_change":"0","version":"1.13.104.0"}],"id":{"product":"dac1034844fb4856950db71b5b2c959d","version":"84030a6b355e4e88898bcd7a79cd2caa"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel i40ea Driver for Windows Server 2019"},{"lang":"ja","x_late":"HPE Intel i40eaドライバー for Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"1572","subdev":"0000","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"158A","subdev":"0000","subven":"1590","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product added implementation of Advanced Link Speed functionality in Physical Function (PF) driver that are supports dynamic link speed changes.</p>\n","latest_fixes_x_late":"<ul>\n\t<li>This product correct an issue which Blue Screen of Death （BSOD） (0x133) occurred with Remote Access Role service during shutdown.</li>\n\t<li>This product correct an issue which system crashed after few modifying Intel&reg; Advanced Network Services (Intel&reg; ans) Team type with tagged Virtual Local Area Network (VLAN).</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product corrects an traffic packets making cert failure seen when packets transferred to VLAN after RDMA function enabled.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"i40ea68.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the iSCSI driver for the HPE Blade Emulex 10/20GbE Server Adapters running under VMware vSphere 6.5."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;12.0.1108.0.</p>\n"}],"files":[{"bytes":"3341568","datemodified":"2019-10-24T14:37:03","file_list":["/cp039936.xml","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/elxiscsi-12.0.1108.0-1OEM.650.0.0.4598673.x86_64.vib","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/ELX-ESX-libelxima.so-12.0.1108.0.vib","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/doc/README.txt","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/doc/release_note_elxiscsi_12.0.1108.0-1OEM.650.0.0.4598673.txt","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/index.xml","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/vendor-index.xml","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/metadata.zip","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/vib20/elx-esx-libelxima.so/ELX_bootbank_elx-esx-libelxima.so_12.0.1108.0-03.vib","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/vib20/elxiscsi/EMU_bootbank_elxiscsi_12.0.1108.0-1OEM.650.0.0.4598673.vib","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/metadata.zip/vmware.xml","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0.xml","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/metadata.zip/vibs/elx-esx-libelxima.so--741715821.xml","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/metadata.zip/vibs/elxiscsi--787023163.xml"],"md5sum":"fa4361c79e2869122c946da143c62bed","name":"cp039936.zip","release":"2019-10-24T19:37:03","revision":"0","sha1sum":"95a8b6c220987ec7f4ee35fe6da18acda5eb4273","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb358b4ee","20a6e8e4-bf33-4c71-a6bf-d9ec1c488a85"],"type_of_change":"0","version":"2019.12.20","vib_list":[{"name":"elx-esx-libelxima.so","version":"12.0.1108.0-03"},{"name":"elxiscsi","version":"12.0.1108.0-1OEM.650.0.0.4598673"}]}],"id":{"product":"957f29fa54a8424d9d2bb2a2851bdb01","version":"a32b530800ed48e1b2c6c24bcfddb559"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE iSCSI Driver for VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"0722","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-11-08T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"elxiscsi:12.0.1108.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"},{"name":"elx-esx-libelxima.so:12.0.1108.0-03","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HP Ethernet 10Gb 2-port 560FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":60,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-10F8103C18D0","Version":"1.2836.0"},{"DeviceName":"HP Ethernet 10Gb 2-port 560M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":60,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-10F8103C17D2","Version":"1.2836.0"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Blade ProLiant Intel Gigabit Ethernet NICs ROM images running under running under VMware vSphere 6.5, 6.7, and 7.0."},{"lang":"ja","x_late":"このパッケージには、VMware vSphere 6.5、6.7、および7.0で動作するHPE Blade ProLiant Intel Gigabit Ethernet NIC ROMイメージをアップグレードするためのユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions for the below listed supported nework adapters:</p>\n\n<table border=\"1\">\n\t<thead>\n\t\t<tr>\n\t\t\t<th>NIC</th>\n\t\t\t<th>EEPROM/NVM Version</th>\n\t\t\t<th>OROM Version</th>\n\t\t</tr>\n\t</thead>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 560FLB Adapter</td>\n\t\t\t<td>800008F0</td>\n\t\t\t<td>1.2836.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 560M Adapter</td>\n\t\t\t<td>8000083D</td>\n\t\t\t<td>1.2836.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>The combo image v1.2836.0 includes: Boot Agent: 1GbE - v1.5.88, 10GbE - v2.4.44, 40GbE - v1.1.18&nbsp;&amp; UEFI Drivers: 1GbE - v9.4.06, 10GbE - v7.8.13, 40GbE - v4.4.12</p>\n"}],"files":[{"bytes":"9249571","datemodified":"2021-03-31T19:54:09","file_list":["/CP045076_BUILD_10.data","/CP045076.vmexe","/CP045076.vmexe64","/CP045076.vmfile","/CP045076_VMw.zip","/CP045076.xml","/payload.json","/CP045076_VMw.zip/index.xml","/CP045076_VMw.zip/vendor-index.xml","/CP045076_VMw.zip/metadata.zip","/CP045076_VMw.zip/vib20/CP045076/HPE_bootbank_CP045076_1.2.2.10-7.0.0.15843807.vib","/CP045076_VMw.zip/metadata.zip/vendor-index.xml","/CP045076_VMw.zip/metadata.zip/vmware.xml","/CP045076_VMw.zip/metadata.zip/vibs/CP045076--3289781217789523104.xml","/CP045076_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045076_1.2.2.10-7.0.0.15843807.xml"],"md5sum":"a79a420777f38e6bb0a58f35d2ea57a6","name":"CP045076.zip","release":"2021-03-31T19:51:05","revision":"0","sha1sum":"f93fe83298834a220ed43d37ef5bb5331bc5da6f","size":"8MB","target_guids":["a6b1a447-382a-5a4f-8086-10F8103C18D0","a6b1a447-382a-5a4f-8086-10F8103C17D2"],"type_of_change":"0","version":"1.2.3","vib_list":[{"name":"CP045076","version":"1.2.2.10-7.0.0.15843807"}]}],"id":{"product":"cbe5961cc6764856bfc9b1b69b78fe4d","version":"51c86cb16f4e4611853f4692b84ff444"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf57995ac","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.6.4-1","description":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"12.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf57995ac","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.6.4-1","description":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf57995ac","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.6.4-1","description":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"15.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf57995ac","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.6.4-1","description":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"7.6"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec05844b56","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.6.4-1","description":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"7.7"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec05844b56","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.6.4-1","description":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"8.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec05844b56","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.6.4-1","description":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgben Driver version 1.7.20-1OEM.600.0.0.2768847 or greater is required and should be already active","OSVersion":{"name":"VMWare","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4a9c3d5c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.7.20-1OEM.600.0.0.2768847","description":"HPE Blade Intel ixgben Driver version 1.7.20-1OEM.600.0.0.2768847 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgben Driver version 1.7.20-1OEM.670.0.0.8169922 or greater is required and should be already active","OSVersion":{"name":"VMWare","value":"6.7"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4a9c3d5c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.7.20-1OEM.670.0.0.8169922","description":"HPE Blade Intel ixgben Driver version 1.7.20-1OEM.670.0.0.8169922 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Blade Intel ixgben Driver version 1.8.9.0-1OEM.700.1.0.15525992 or greater is required and should be already active","OSVersion":{"name":"VMWare","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.8.9.0-1OEM.700.1.0.15525992","description":"HPE Blade Intel ixgben Driver version 1.8.9.0-1OEM.700.1.0.15525992 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Manual installation instructions:</p>\n\n<ol>\n\t<li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li>\n\t<br />\n\t<li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li>\n\t<br />\n\t<li>Unzip the CPxxxxxx.zip file.</li>\n\t<br />\n\t<li>Install the VMware component.\n\t<ol>\n\t\t<li>For ESXi 7.0 targets:&nbsp;<em>esxcli&nbsp; software component apply &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip</em>. (Example:<em> &quot;</em>esxcli software component apply &ndash;d /tmp/CPxxxxxx_VMware.zip&quot;)</li>\n\t\t<br />\n\t\t<li>For ESXi 6.x targets:&nbsp;<em>esxcli software vib install &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip</em>. (Example: &quot;esxcli software vib install &ndash;d /tmp/CPxxxxxx_VMw.zip&quot;)</li>\n\t</ol>\n\t</li>\n\t<br />\n\t<li>Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li>\n\t<br />\n\t<li>Execute the component with the command set options&nbsp; s, -f, -e, -g, &nbsp;etc. if required. When execution is complete&nbsp;the flash engine will have&nbsp;performed the flash operation as directed.</li>\n\t<br />\n\t<li>Clean up the Smart Component:\n\t<ol>\n\t\t<li>Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li>\n\t\t<br />\n\t\t<li>To clean up the Smart Component:\n\t\t<ol>\n\t\t\t<li>For ESXi 7.0 targets: <em>esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</em></li>\n\t\t\t<br />\n\t\t\t<li>For ESXi 6.x targets: <em>esxcli software vib remove &ndash;n CPxxxxxx</em></li>\n\t\t</ol>\n\t\t</li>\n\t\t<br />\n\t\t<li>Remove the directories associated with CPxxxxxx: <em>rm -rf&nbsp;/opt/Smart_Component/CPxxxxxx</em></li>\n\t</ol>\n\t</li>\n\t<br />\n\t<li>If reboot is required to complete the firmware installation, reboot your system.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p>手動によるインストール手順：</p>\n\n<ol>\n\t<li>Smartコンポーネント（CPxxxxxx.zip）をESXiホストの空き容量が十分にある場所にコピーします。（例：\"/tmp\"）</li>\n\t<br />\n\t<li>手順1でCPxxxxxx.zipファイルがコピーされた場所に移動します。</li>\n\t<br />\n\t<li>CPxxxxxx.zipファイルをunzipします。</li>\n\t<br />\n\t<li>VMwareコンポーネントをインストールします。\n\t<ol>\n\t\t<li>ESXi 7.0ターゲットの場合：<em>esxcli  software component apply –d <fully_qualified_path>/CPxxxxxx_VMw.zip</em> （例：<em></em>\"esxcli software component apply –d /tmp/CPxxxxxx_VMware.zip\"）</li>\n\t\t<br />\n\t\t<li>ESXi 6.xターゲットの場合：<em>esxcli software vib install –d <fully_qualified_path>/CPxxxxxx_VMw.zip</em> （例：\"esxcli software vib install –d /tmp/CPxxxxxx_VMw.zip\"）</li>\n\t</ol>\n\t</li>\n\t<br />\n\t<li>コンポーネントがインストールされている場所に移動します。（例：\"cd /opt/Smart_Component/CPxxxxxx\"）</li>\n\t<br />\n\t<li>必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを使用してコンポーネントを実行します。実行が完了すると、フラッシュエンジンが指示どおりにフラッシュ操作を実行します。</li>\n\t<br />\n\t<li>Smartコンポーネントをクリーンアップします。\n\t<ol>\n\t\t<li>/opt/Smart_Component/CPxxxxxから別の場所に移動します。（例：\"/tmp\"）</li>\n\t\t<br />\n\t\t<li>Smartコンポーネントをクリーンアップするには：\n\t\t<ol>\n\t\t\t<li>ESXi 7.0ターゲットの場合：<em>esxcli software component remove –n Smart-Component-CPxxxxxx</em></li>\n\t\t\t<br />\n\t\t\t<li>ESXi 6.xターゲットの場合：<em>esxcli software vib remove –n CPxxxxxx</em></li>\n\t\t</ol>\n\t\t</li>\n\t\t<br />\n\t\t<li>CPxxxxxxに関連付けられているディレクトリを削除します：<em>rm -rf /opt/Smart_Component/CPxxxxxx</em></li>\n\t</ol>\n\t</li>\n\t<br />\n\t<li>ファームウェアのインストールを完了するために再起動が必要な場合は、システムを再起動します。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Intel Online Firmware Upgrade Utility for VMware"},{"lang":"ja","x_late":"HPE Blade Intelオンラインファームウェアアップグレードユーティリティfor VMware"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports VMware ESXi&nbsp;7.0.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports VMware vSphere 7.0 U1.<br />\nThis product now supports VMware vSphere 6.7 U3.<br />\nThis product now supports VMware vSphere 6.5 U3.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"INTEL_BL","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MT001600KWHAC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPS1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3130-3630-304b57484143","Version":"HPS1"},{"DeviceName":"MT003200KWHAD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPS1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3330-3230-304b57484144","Version":"HPS1"},{"DeviceName":"MT006400KWHAE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPS1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3630-3430-304b57484145","Version":"HPS1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MT001600KWHAC, MT003200KWHAD and MT006400KWHAE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for VMware ESXi -&nbsp;MT001600KWHAC, MT003200KWHAD and MT006400KWHAE Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPS1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"20271562","datemodified":"2021-09-24T10:28:34","file_list":["/CP048488_BUILD_2.data","/CP048488.vmexe","/CP048488.vmexe64","/CP048488.vmfile","/CP048488_VMw.zip","/CP048488.xml","/payload.json","/CP048488_VMw.zip/index.xml","/CP048488_VMw.zip/vendor-index.xml","/CP048488_VMw.zip/metadata.zip","/CP048488_VMw.zip/vib20/CP048488/HPE_bootbank_CP048488_HPS1.2-7.0.0.15843807.vib","/CP048488_VMw.zip/metadata.zip/vendor-index.xml","/CP048488_VMw.zip/metadata.zip/vmware.xml","/CP048488_VMw.zip/metadata.zip/vibs/CP048488--2140184322011497156.xml","/CP048488_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048488_HPS1.2-7.0.0.15843807.xml"],"md5sum":"e37b8aa1ac81e2093482d82b1c08e4c5","name":"CP048488.zip","release":"2021-09-24T10:22:14","revision":"0","sha1sum":"be5dceffd9b0d35d348949e9b97df99b40b5e479","size":"19MB","target_guids":["4d2340a5-3054-3130-3630-304b57484143","4d2340a5-3054-3330-3230-304b57484144","4d2340a5-3054-3630-3430-304b57484145"],"type_of_change":"1","version":"HPS1","vib_list":[{"name":"CP048488","version":"HPS1.2-7.0.0.15843807"}]}],"id":{"product":"bc640709bf9a4728898e83ba80473c0a","version":"74013c279a1f464da0718b0dd1e039a2"},"installation":{"command":"CP040212.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi  - MT001600KWHAC, MT003200KWHAD and MT006400KWHAE Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - MT001600KWHAC、MT003200KWHADおよびMT006400KWHAEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MT006400KWHAE","target_guid":"4d2340a5-3054-3630-3430-304b57484145","type":"nvme"},{"id":"MT003200KWHAD","target_guid":"4d2340a5-3054-3330-3230-304b57484144","type":"nvme"},{"id":"MT001600KWHAC","target_guid":"4d2340a5-3054-3130-3630-304b57484143","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-14T09:02:34","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MT003200KWHAD","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT001600KWHAC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT006400KWHAE","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]},{"key":"7800374","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"en","x_late":"This package contains the kit to provide support for Smart SAN on Emulex fibre channel host bus adapters on Linux operating systems."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"21028","datemodified":"2021-08-26T06:33:04","file_list":["./opt/hpe/elx_smartsan/SmartSAN.sh","./opt/hpe/elx_smartsan/elx_ss_enablement","./opt/hpe/elx_smartsan/readme.txt","./usr/share/smartupdate/hpe-emulex-smartsan-enablement-kit/component.xml"],"md5sum":"02153bb6194bcacf97f05afdee827fe2","name":"hpe-emulex-smartsan-enablement-kit-1.0.0.0-4.x86_64.rpm","release":"2021-08-26T06:27:04","revision":"0","sha1sum":"60c751988a12cba74a720251070989fad8bded59","size":"20KB","target_guids":[],"type_of_change":"0","version":"1.0.0.0-4"}],"id":{"product":"185f484949d24de98341a6cf06fb466e","version":"daf4044df3364de5a80c6461615fd509"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>SmartSAN is a 64 bit&nbsp;specific kit.&nbsp;It is recommended that you uninstall any previous kits prior to installation of this component.</p>\n\n<p style=\"margin-left:40px\">To uninstall the Emulex Smart SAN enablement RPM use the following command:</p>\n\n<p style=\"margin-left:40px\"># rpm -e hpe-emulex-smartsan-enablement-&lt;version&gt;.noarch.rpm</p>\n\n<p>This is a configurable component.&nbsp; It requires a configuration file in order to enable/disable Smart SAN functionality.&nbsp; If no configuration is performed, the current Smart SAN status is stated and the execution is complete.&nbsp; No further action is taken.</p>\n\n<p>&nbsp;</p>\n\n<p>For detailed information about configurable components, see the&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00106063en_us\"><em>Smart Update Manager User Guide </em></a></p>\n\n<p>&nbsp;</p>\n\n<p><strong>Component execution outside of HPE Service Pack for Proliant</strong>:</p>\n\n<p style=\"margin-left:40px\">1.&nbsp;Login as the system administrator (root).</p>\n\n<p style=\"margin-left:40px\">2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p style=\"margin-left:40px\">3.&nbsp;To install, type the following command at the prompt:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -ivh hpe-emulex-smartsan-enablement-kit-&lt;version&gt;.x86_64.rpm<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -ivh hpe-emulex-smartsan-enablement-kit-1.0.0.0-1.x86_64.rpm</p>\n\n<p style=\"margin-left:40px\">4.&nbsp;When the installation or upgrade is complete, the following message displays:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Installation complete</p>\n\n<p style=\"margin-left:40px\">&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex Smart SAN Enablement Kit for Linux"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T09:15:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added support to SLES15SP3</p>\n\n<p>Updated to version 1.0.0.0-4</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"hpe-emulex-smartsan-enablement-kit","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000JEQNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPSCDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a45514e4c","Version":"HPDB"},{"DeviceName":"MB6000JEQNN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPSCDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a45514e4e","Version":"HPDB"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SAS drive models: MB4000JEQNL and MB6000JEQNN"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSASドライブモデルのファームウェアを提供します。 MB4000JEQNLおよびMB6000JEQNN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB4000JEQNL and MB6000JEQNN Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPDB<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5553580","datemodified":"2021-07-23T07:22:11","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-2cfaac41db-HPDB-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-2cfaac41db-HPDB-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-2cfaac41db-HPDB-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2cfaac41db-HPDB-8.1/CP048164.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-2cfaac41db-HPDB-8.1/HAKPSCDB.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-2cfaac41db-HPDB-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2cfaac41db-HPDB-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-2cfaac41db-HPDB-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-2cfaac41db-HPDB-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048164.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048164.scexe"],"md5sum":"ef3176221c6d8ebdb98f5bc89b4ac0b7","name":"firmware-hdd-2cfaac41db-HPDB-8.1.x86_64.rpm","release":"2021-07-23T07:09:12","revision":"0","sha1sum":"09b8a30f7c6914458e7f9dd2e2f551ee106e01f9","size":"5MB","target_guids":["002340a5-4d00-3442-3030-304a45514e4c","002340a5-4d00-3642-3030-304a45514e4e"],"type_of_change":"1","version":"HPDB"}],"id":{"product":"57f299c4757147d2a235078cf35bab3f","version":"a9db5f24802e45cea91b7cb3f0eabee0"},"installation":{"command":"CP040264.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB4000JEQNL and MB6000JEQNN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB4000JEQNLおよびMB6000JEQNNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"MB4000JEQNL","target_guid":"002340a5-4d00-3442-3030-304a45514e4c","type":"sas"},{"id":"MB6000JEQNN","target_guid":"002340a5-4d00-3642-3030-304a45514e4e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T19:22:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JEQNL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB6000JEQNN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel and Mezzanine Host Bus Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"586304","datemodified":"2021-08-26T08:59:59","file_list":["./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/lpfc.ko","./usr/share/smartupdate/elx-lpfc-kmp-default/component.xml"],"md5sum":"053801f55613ed7d37b61825f7142df6","name":"elx-lpfc-kmp-default-12.8.528.7_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-08-26T08:52:08","revision":"0","sha1sum":"bd05a08f0eb6dac8998447abbf25e3427d6a0007","size":"572KB","target_guids":[],"type_of_change":"1","version":"12.8.528.7"}],"id":{"product":"268b68473c904fb493e7bc2627fd85b7","version":"67d19d1ba2014bd58a520e57cf14481b"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh elx-lpfc-kmp-default-12.8.509.3_k5.3.18_51-1.sles15sp3.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>\n\n<p>Rewrite of same Driver version has to be performed using &ndash;reinstall option</p>\n\n<p>Example: rpm &ndash;Uvh elx-lpfc-kmp-default-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm &ndash;reinstall</p>\n\n<p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"SUSE Linux Enterprise Server 15 Service Pack 2 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters and Mezzanine Host Bus Adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"F100","subven":"10DF","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T10:36:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to driver version 12.8.528.7</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"elx-lpfc-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB1000JVYZL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3142-3030-304a56595a4c","Version":"HPD3"},{"DeviceName":"MB2000JVYZN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a56595a4e","Version":"HPD3"},{"DeviceName":"MB3000JVYZP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304a56595a50","Version":"HPD3"},{"DeviceName":"MB4000JVYZQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a56595a51","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB1000JVYZL, MB2000JVYZN, MB3000JVYZP and MB4000JVYZQ"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB1000JVYZL、MB2000JVYZN、MB3000JVYZPおよびMB4000JVYZQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB1000JVYZL, MB2000JVYZN, MB3000JVYZP&nbsp;and MB4000JVYZQ Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3594576","datemodified":"2021-07-25T13:09:13","file_list":["cp048569.xml","cpqsetup.exe","payload.json","setup.dll","SMBPNSD3.rel"],"md5sum":"7cd3da5ad5bfb0374c1b925296a57cb0","name":"cp048569.exe","release":"2021-07-25T13:01:07","revision":"0","sha1sum":"ef4d0528a2f63e317d8a7b2c9e1e7c62038b1344","size":"3MB","target_guids":["002340a5-4d00-3142-3030-304a56595a4c","002340a5-4d00-3242-3030-304a56595a4e","002340a5-4d00-3342-3030-304a56595a50","002340a5-4d00-3442-3030-304a56595a51"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"85555c0bf7a54baebd117b6f0dbd865a","version":"476c7383fb234fe09957cc990ad460e3"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB1000JVYZL, MB2000JVYZN, MB3000JVYZP and MB4000JVYZQ Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB1000JVYZL、MB2000JVYZN、MB3000JVYZP、およびMB4000JVYZQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB1000JVYZL","target_guid":"002340a5-4d00-3142-3030-304a56595a4c","type":"sas"},{"id":"MB2000JVYZN","target_guid":"002340a5-4d00-3242-3030-304a56595a4e","type":"sas"},{"id":"MB3000JVYZP","target_guid":"002340a5-4d00-3342-3030-304a56595a50","type":"sas"},{"id":"MB4000JVYZQ","target_guid":"002340a5-4d00-3442-3030-304a56595a51","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T07:56:55","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB1000JVYZL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB2000JVYZN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB3000JVYZP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB4000JVYZQ","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"本產品包含 SUSE Linux Enterprise Server 12 x86_64 下執行的 HPE Intel i40e 乙太網路 NIC 驅動程式。"},{"lang":"en","x_late":"This product contains the drivers for the HPE Intel i40e Ethernet NICs running under SUSE Linux Enterprise Server 12 x86_64."},{"lang":"ko","x_late":"이 제품에는 SUSE Linux Enterprise Server 12 x86_64에서 실행되는 HPE Intel i40e 이더넷 NIC용 드라이버가 포함되어 있습니다."},{"lang":"cn","x_late":"本产品包含适用于在SUSE Linux Enterprise Server 12 x86_64下运行的HPE Intel i40e以太网网卡驱动程序。"},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12 x86_64で動作するHPE Intel i40e Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"3770536","datemodified":"2021-09-05T12:38:03","file_list":["./etc/depmod.d/hp-i40e.conf","./etc/dracut.conf.d/hp-i40e-oob.conf","./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/hp-i40e","./lib/modules/4.12.14-94.41-default/updates/hp-i40e/i40e.ko","./usr/share/smartupdate/hp-i40e-kmp-default/component.xml"],"md5sum":"f98c1c6a4673ab12e7ae81ee8fa4736e","name":"hp-i40e-kmp-default-2.14.13_k4.12.14_94.41-1.sles12sp4.x86_64.rpm","release":"2021-09-05T12:29:05","revision":"0","sha1sum":"a53651a6181401cd09a91201442aaac505a1effa","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccb9b3dbd"],"type_of_change":"0","version":"2.14.13-1"},{"bytes":"3926480","datemodified":"2021-09-05T12:40:54","file_list":["./etc/depmod.d/hp-i40e.conf","./etc/dracut.conf.d/hp-i40e-oob.conf","./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/hp-i40e","./lib/modules/4.12.14-120-default/updates/hp-i40e/i40e.ko","./usr/share/smartupdate/hp-i40e-kmp-default/component.xml"],"md5sum":"2ddf80be4dbbad068469599467c82269","name":"hp-i40e-kmp-default-2.14.13_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-09-05T12:29:05","revision":"0","sha1sum":"133e251bc3efac99942f5fe2faeccb205005e0b2","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccb9b3dbd"],"type_of_change":"0","version":"2.14.13-1"}],"id":{"product":"9cc198d5db9a4dc58d7191dc280dcc88","version":"598a5d16b09740a2b21e28a8c8cd0a2c"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"},{"lang":"ja","x_late":"<p>インストールのノートについてREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 SUSE Linux Enterprise Server 12 x86_64 的 HPE Intel i40e 驅動程式"},{"lang":"en","x_late":"HPE Intel i40e Drivers for SUSE Linux Enterprise Server 12 x86_64"},{"lang":"ko","x_late":"SUSE Linux Enterprise Server 12 x86_64용 HPE Intel i40e 드라이버"},{"lang":"cn","x_late":"SUSE Linux Enterprise Server 12 x86_64版HPE Intel i40e驱动程序"},{"lang":"ja","x_late":"HPE Intel i40eドライバー for SUSE Linux Enterprise Server 12 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"},{"dev":"1572","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1572808600a1","type":"pci","ven":"8086"},{"dev":"1572","subdev":"0008","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-157280860008","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"1581","subdev":"00F8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1581159000f8","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-10-02T12:56:43","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue where the driver could result in kernel instability under heavy network conditions. Recommend to use this version 2.14.13(or later) as suggested by Intel TA-256(Technical Advisory).</p>\n"},{"curr_enhancements_x_late":"<p>This product supports the following new server:</p>\n\n<ul>\n\t<li>HPE ProLiant DL20 Gen10 Plus Server</li>\n\t<li>HPE ProLiant ML30 Gen10 Plus Server&nbsp;<br />\n\t&nbsp;</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"hp-i40e-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-i40e-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-i40e-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-i40e-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB1000GDUNU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3142-3030-304744554e55","Version":"HPG4"},{"DeviceName":"MB2000GDUNV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304744554e56","Version":"HPG4"},{"DeviceName":"MB3000GDUPA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304744555041","Version":"HPG4"},{"DeviceName":"MB4000GDUPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304744555042","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB1000GDUNU, MB2000GDUNV, MB3000GDUPA and MB4000GDUPB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB1000GDUNU, MB2000GDUNV, MB3000GDUPA&nbsp;and MB4000GDUPB drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<ul>\n\t<li>Firmware cannot be downgraded to HPG3 after updating to HPG4.</li>\n</ul>\n"}],"files":[{"bytes":"3388752","datemodified":"2021-07-25T12:46:54","file_list":["cp048564.xml","cpqsetup.exe","payload.json","setup.dll","TAHARRG4.REL"],"md5sum":"9cfc623fcd198d6119f9334e04ebf808","name":"cp048564.exe","release":"2021-07-25T12:39:05","revision":"0","sha1sum":"546d4fbf0b9ed1e6e563b914806370f424c3ca36","size":"3MB","target_guids":["002340a5-4d00-3142-3030-304744554e55","002340a5-4d00-3242-3030-304744554e56","002340a5-4d00-3342-3030-304744555041","002340a5-4d00-3442-3030-304744555042"],"type_of_change":"1","version":"HPG4"}],"id":{"product":"dceed791e6be42c1ba1f138aa6af8451","version":"87bf924e90bc44bdab40dde93d2d6ec5"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB1000GDUNU, MB2000GDUNV, MB3000GDUPA and MB4000GDUPB Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB1000GDUNU、MB2000GDUNV、MB3000GDUPA、および MB4000GDUPB ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB1000GDUNU","target_guid":"002340a5-4d00-3142-3030-304744554e55","type":"sata"},{"id":"MB2000GDUNV","target_guid":"002340a5-4d00-3242-3030-304744554e56","type":"sata"},{"id":"MB3000GDUPA","target_guid":"002340a5-4d00-3342-3030-304744555041","type":"sata"},{"id":"MB4000GDUPB","target_guid":"002340a5-4d00-3442-3030-304744555042","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T07:04:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB2000GDUNV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB3000GDUPA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB4000GDUPB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB1000GDUNU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK0240GEPQN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM853G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3234-30474550514e","Version":"HPG1"},{"DeviceName":"VK0480GEPQP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM853G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3438-304745505150","Version":"HPG1"},{"DeviceName":"VK0960GEPQQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM853G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3936-304745505151","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK0240GEPQN, VK0480GEPQP and VK0960GEPQQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;&nbsp;VK0240GEPQN, VK0480GEPQP and VK0960GEPQQ Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"2921016","datemodified":"2021-07-25T19:27:07","file_list":["cp048642.xml","cpqsetup.exe","GPM853G1.rel","payload.json","setup.dll"],"md5sum":"738948c399e0dae32fc52ad5e431c59c","name":"cp048642.exe","release":"2021-07-25T19:20:04","revision":"0","sha1sum":"dfbbb8ec7a68f6acb62acc1cdd2b76f420d78b2d","size":"2MB","target_guids":["002340a5-5600-304b-3234-30474550514e","002340a5-5600-304b-3438-304745505150","002340a5-5600-304b-3936-304745505151"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"6f3decdb759d4bafa6df9af42f08e497","version":"64489e1f65a843c59317a9ed5167d345"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK0240GEPQN, VK0480GEPQP and VK0960GEPQQ Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - VK0240GEPQN、VK0480GEPQP、およびVK0960GEPQQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VK0240GEPQN","target_guid":"002340a5-5600-304b-3234-30474550514e","type":"sata"},{"id":"VK0480GEPQP","target_guid":"002340a5-5600-304b-3438-304745505150","type":"sata"},{"id":"VK0960GEPQQ","target_guid":"002340a5-5600-304b-3936-304745505151","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T17:28:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK0960GEPQQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0240GEPQN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0480GEPQP","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6246723","datemodified":"2021-05-18T14:20:11","file_list":["./usr/lib/i386-linux-gnu/firmware-system-u18-2.90_2021_04_29-1.1","./usr/lib/i386-linux-gnu/firmware-system-u18-2.90_2021_04_29-1.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-system-u18-2.90_2021_04_29-1.1/.setup","./usr/lib/i386-linux-gnu/firmware-system-u18-2.90_2021_04_29-1.1/CP047898.xml","./usr/lib/i386-linux-gnu/firmware-system-u18-2.90_2021_04_29-1.1/U18_2.90_04_29_2021.signed.flash","./usr/lib/i386-linux-gnu/firmware-system-u18-2.90_2021_04_29-1.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-system-u18-2.90_2021_04_29-1.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP047898.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP047898.scexe"],"md5sum":"71ff896cfe013313f8cb0a6ab955891d","name":"firmware-system-u18-2.90_2021_04_29-1.1.i386.rpm","release":"2021-05-18T14:11:05","revision":"0","sha1sum":"3c5ee8c6d093c137fda5e616118a81047f943ee9","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021"}],"id":{"product":"10608c086312418089d4590d5f0549ab","version":"b24e77477f254a789561eb55ebef3b2f"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HPE ProLiant Agentless Management Service (<strong>AMS</strong>) and HPE SNMP Agents (<strong>SNMP Agents</strong>) are both running.&nbsp; HPE does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager 8.0.0 or later, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、iLOとの通信ができない場合に失敗します。  これは、HPE ProLiant Agentless Management Service (<strong>AMS</strong>)およびHPE SNMPエージェント(<strong>SNMP Agents</strong>)の両方が実行されているときに発生します。  HPEでは、AMSおよびSNMPエージェントを同時に実行させないことを推奨します。  「iLO device not found」エラーが発生した場合、AMSまたはSNMPエージェントを停止させて、再度フラッシュコンポーネントを実行します。<br />\n<br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上のSmart Update Manager 8.0.0以降を使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant XL730f/XL740f/XL750f Gen9 (U18) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant XL730f/XL740f/XL750f Gen9(U18)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-06T21:40:15","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","latest_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358.  These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390.  These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"}],"sw_keys":[{"name":"U18","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWSXF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757535846","Version":"HPG3"},{"DeviceName":"VK000960GWSXH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757535848","Version":"HPG3"},{"DeviceName":"VK001920GWSXK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-30475753584b","Version":"HPG3"},{"DeviceName":"MK000480GWUGF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757554746","Version":"HPG3"},{"DeviceName":"MK000960GWUGH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757554748","Version":"HPG3"},{"DeviceName":"MK001920GWUGK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475755474b","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK000480GWSXF, VK000960GWSXH, VK001920GWSXK, MK000480GWUGF, MK000960GWUGH and MK001920GWUGK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;VK000480GWSXF, VK000960GWSXH, VK001920GWSXK, MK000480GWUGF, MK000960GWUGH and&nbsp;MK001920GWUGK&nbsp; Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG2</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG2<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"3137224","datemodified":"2021-07-25T18:52:57","file_list":["cp048638.xml","cpqsetup.exe","M5200SG3.rel","payload.json","setup.dll"],"md5sum":"858d913900f19c5c331840f21554631b","name":"cp048638.exe","release":"2021-07-25T18:46:04","revision":"0","sha1sum":"3ae62fdb4cac4db208510e309b8e24209971dd79","size":"2MB","target_guids":["562340a5-304b-3030-3438-304757535846","562340a5-304b-3030-3936-304757535848","562340a5-304b-3130-3932-30475753584b","4d2340a5-304b-3030-3438-304757554746","4d2340a5-304b-3030-3936-304757554748","4d2340a5-304b-3130-3932-30475755474b"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"75bc856a96a1425a954558bdb79908f8","version":"499e970ea43d4d28b6ec55dd87f80cd7"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK000480GWSXF, VK000960GWSXH, VK001920GWSXK, MK000480GWUGF, MK000960GWUGH and MK001920GWUGK Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - VK000480GWSXF、VK000960GWSXH、VK001920GWSXK、MK000480GWUGF、MK000960GWUGH、MK001920GWUGKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VK001920GWSXK","target_guid":"562340a5-304b-3130-3932-30475753584b","type":"sata"},{"id":"MK001920GWUGK","target_guid":"4d2340a5-304b-3130-3932-30475755474b","type":"sata"},{"id":"VK000960GWSXH","target_guid":"562340a5-304b-3030-3936-304757535848","type":"sata"},{"id":"MK000960GWUGH","target_guid":"4d2340a5-304b-3030-3936-304757554748","type":"sata"},{"id":"VK000480GWSXF","target_guid":"562340a5-304b-3030-3438-304757535846","type":"sata"},{"id":"MK000480GWUGF","target_guid":"4d2340a5-304b-3030-3438-304757554746","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T16:51:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Improved Product Quality and Reliability. Changed Cap Charge Timeout to 14 seconds from 4 seconds to provide additional time for cap charge in marginal power environment.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK000480GWUGF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK001920GWUGK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWUGH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWSXF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GWSXK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWSXH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000240GWCEU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3234-304757434555","Version":"HPG3"},{"DeviceName":"MK000480GWCEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757434556","Version":"HPG3"},{"DeviceName":"MK000960GWCFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757434641","Version":"HPG3"},{"DeviceName":"MK001920GWCFB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304757434642","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MK000240GWCEU, MK000480GWCEV, MK000960GWCFA and MK001920GWCFB Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MK000240GWCEU、MK000480GWCEV、MK000960GWCFA、およびMK001920GWCFBドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;&nbsp;MK000240GWCEU, MK000480GWCEV, MK000960GWCFA&nbsp;and MK001920GWCFB&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4665784","datemodified":"2021-07-23T07:48:13","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-7677644a25-HPG3-7.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-7677644a25-HPG3-7.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-7677644a25-HPG3-7.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7677644a25-HPG3-7.1/CP048176.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-7677644a25-HPG3-7.1/GS863aG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-7677644a25-HPG3-7.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7677644a25-HPG3-7.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-7677644a25-HPG3-7.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-7677644a25-HPG3-7.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048176.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048176.scexe"],"md5sum":"9800057929cfe1d85316519079b72e9a","name":"firmware-hdd-7677644a25-HPG3-7.1.x86_64.rpm","release":"2021-07-23T07:34:14","revision":"0","sha1sum":"019ff21caf3f9d23f8a9b213a06c3be8c5c2188c","size":"4MB","target_guids":["4d2340a5-304b-3030-3234-304757434555","4d2340a5-304b-3030-3438-304757434556","4d2340a5-304b-3030-3936-304757434641","4d2340a5-304b-3130-3932-304757434642"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"8da11b65fc4a442eb7c1c3ce3ad367bb","version":"037658bbe87041298dcdcdc3267a9431"},"installation":{"command":"CP040341.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MK000240GWCEU, MK000480GWCEV, MK000960GWCFA and MK001920GWCFB Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MK000240GWCEU、MK000480GWCEV、MK000960GWCFAおよびMK001920GWCFBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MK001920GWCFB","target_guid":"4d2340a5-304b-3130-3932-304757434642","type":"sata"},{"id":"MK000240GWCEU","target_guid":"4d2340a5-304b-3030-3234-304757434555","type":"sata"},{"id":"MK000480GWCEV","target_guid":"4d2340a5-304b-3030-3438-304757434556","type":"sata"},{"id":"MK000960GWCFA","target_guid":"4d2340a5-304b-3030-3936-304757434641","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T20:13:43","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK000240GWCEU","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWCFA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK001920GWCFB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWCEV","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"8762675","datemodified":"2021-05-17T22:28:43","file_list":["/CP047834.vmexe","/CP047834.vmexe64","/CP047834.vmfile","/CP047834.xml","/README.txt"],"md5sum":"490edf7c8ce75e09b074bbb6a226e525","name":"CP047834.zip","release":"2021-05-18T03:25:14","revision":"0","sha1sum":"6fc7bbe7d2a8a2f74d9814df14b55cfff9cf830a","size":"8MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021","vib_list":[]}],"id":{"product":"ae3d527d10354a82bc7ece2ff1ca3e96","version":"d65122cec6514a5d8d6eb7c3865d0886"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component requires that the CRU driver be loaded before the component can run.</p>\n\n<p>The minimum CRU version for 5.1 is 5.0.3.9.<br />\nThe minimum CRU version for 5.5 is 5.5.4.1.<br />\nThe minimum CRU version for 6.0 is 6.0.8.<br />\nThe minimum CRU version for 6.5 is 6.5.8.<br />\nThe minimum CRU version for 6.7 is 6.7.10.<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>SPP Offline mode boots a special Linux OS environment, thus the Linux Components are used, not the VMware Components</li>\n</ul>\n\n<p><br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Download the appropriate SPP</li>\n\t<li>Add the component to the SPP</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run&nbsp; SUM</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps to complete the firmware update</li>\n\t<li>Refer to the SPP documentation for detailed instructions at:&nbsp; <a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Component ( CPxxxxxx.zip) in a temporary directory</li>\n\t<li>From the same directory, unzip the Component:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>To perform the standalone installation, execute the command:<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>Follow the directions given by the Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system for the firmware update to take effect</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、実行する前にCRUドライバーがロードされている必要があります。</p>\n\n<p>5.1の最小CRUバージョンは5.0.3.9です。<br />\n5.5の最小CRUバージョンは5.5.4.1です。<br />\n6.0の最小CRUバージョンは6.0.8です。<br />\n6.5の最小CRUバージョンは6.5.8です。<br />\n6.7の最小CRUバージョンは6.7.10です。<br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMwareコンポーネントではなく、Linuxコンポーネントが用いられます</li>\n</ul>\n\n<p><br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします</li>\n\t<li>SPPにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします</li>\n\t<li>SUMを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います</li>\n\t<li>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>コンポーネント (CPxxxxxx.zip)を一時ディレクトリに置きます</li>\n\t<li>同じディレクトリからコンポーネントをunzipします:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>スタンドアロンのインストールを行うために、次のコマンドを実行します：<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>コンポーネントの指示に従います</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n\t<li>システムを再起動し、ファームウェアのアップデートを有効にします</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware - HPE ProLiant DL380 Gen9/DL360 Gen9  (P89) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for VMware - HPE ProLiant DL380 Gen9/DL360 Gen9（P89）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"5","minor":"1","name":"VMware vSphere 5.1","platform":"vmware_esx_server","sr":"OEM"},{"major":"5","minor":"5","name":"VMware vSphere 5.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-05T02:56:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>Ver. 2.80_10-16-2020(B) contains updates to the component packaging and is functionally equivalent to ver. 2.80_10-16-2020. It is not necessary to upgrade with Revision (B) if a previous component revision was used to upgrade the firmware to 2.80_10-16-2020.</p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"}],"sw_keys":[{"name":"P89","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWBXQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAGLXYG8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304757425851","Version":"HPG8"},{"DeviceName":"MB008000GWBYL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAGLXYG8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-30475742594c","Version":"HPG8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB006000GWBXQ and MB008000GWBYL "},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： MB006000GWBXQおよびMB008000GWBYL "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux - MB006000GWBXQ and MB008000GWBYL Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG6<br />\n<br />\n<strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"6300174","datemodified":"2021-07-23T07:34:44","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a1fd19f9ca-HPG8-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-a1fd19f9ca-HPG8-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a1fd19f9ca-HPG8-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a1fd19f9ca-HPG8-6.1/CP048104.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a1fd19f9ca-HPG8-6.1/TAGLXYG8.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-a1fd19f9ca-HPG8-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a1fd19f9ca-HPG8-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a1fd19f9ca-HPG8-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a1fd19f9ca-HPG8-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048104.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048104.scexe"],"md5sum":"8fd9b86748eb18072985329d76743a01","name":"firmware-hdd-a1fd19f9ca-HPG8-6.1.x86_64.rpm","release":"2021-07-23T07:22:08","revision":"0","sha1sum":"d42a7d7090458a64301f9689b51acea5c9b0887e","size":"6MB","target_guids":["4d2340a5-3042-3630-3030-304757425851","4d2340a5-3042-3830-3030-30475742594c"],"type_of_change":"1","version":"HPG8"}],"id":{"product":"2e44a81a31b2430ba5be31f73e9e365e","version":"cfa375533e3841429371bab9287a415f"},"installation":{"command":"CP040782.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB006000GWBXQ and MB008000GWBYL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB006000GWBXQおよびMB008000GWBYLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB006000GWBXQ","target_guid":"4d2340a5-3042-3630-3030-304757425851","type":"sata"},{"id":"MB008000GWBYL","target_guid":"4d2340a5-3042-3830-3030-30475742594c","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T16:46:34","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000GWBXQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB008000GWBYL","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000960GXCLD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5210AG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304758434c44","Version":"HPG2"},{"DeviceName":"VK001920GXCGP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5210AG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304758434750","Version":"HPG2"},{"DeviceName":"VK003840GXCGQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5210AG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304758434751","Version":"HPG2"},{"DeviceName":"VK007680GXCGR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5210AG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-304758434752","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK000960GXCLD, VK001920GXCGP, VK003840GXCGQ and VK007680GXCGR"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;-&nbsp;VK000960GXCLD, VK001920GXCGP, VK003840GXCGQ and VK007680GXCGR&nbsp; Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4666576","datemodified":"2021-08-13T14:20:24","file_list":["cp049274.xml","cpqsetup.exe","M5210AG2.rel","payload.json","setup.dll"],"md5sum":"6c817e16858d26649eac4241d3671587","name":"cp049274.exe","release":"2021-08-13T14:12:04","revision":"0","sha1sum":"d24012691141fae058f0af023f2636fb5cb3c2e9","size":"4MB","target_guids":["562340a5-304b-3030-3936-304758434c44","562340a5-304b-3130-3932-304758434750","562340a5-304b-3330-3834-304758434751","562340a5-304b-3730-3638-304758434752"],"type_of_change":"1","version":"HPG2"}],"id":{"product":"eba2d683ef74457085f02d6700a97d49","version":"100278b5b3674461b7008206c6b3edc3"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK000960GXCLD, VK001920GXCGP, VK003840GXCGQ and VK007680GXCGR  Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VK000960GXCLD","target_guid":"562340a5-304b-3030-3936-304758434c44","type":"sata"},{"id":"VK007680GXCGR","target_guid":"562340a5-304b-3730-3638-304758434752","type":"sata"},{"id":"VK001920GXCGP","target_guid":"562340a5-304b-3130-3932-304758434750","type":"sata"},{"id":"VK003840GXCGQ","target_guid":"562340a5-304b-3330-3834-304758434751","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-13T14:08:13","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK003840GXCGQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GXCGP","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK007680GXCGR","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GXCLD","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG1800JEHMD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFL4CD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3830-304a45484d44","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: EG1800JEHMD"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 EG1800JEHMD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - EG1800JEHMD Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None.</p>\n"}],"files":[{"bytes":"3653824","datemodified":"2021-07-24T06:24:57","file_list":["cp048507.xml","cpqsetup.exe","HCFL4CD6.rel","payload.json","setup.dll"],"md5sum":"001f0399bab73e9a965a54f5acbf079c","name":"cp048507.exe","release":"2021-07-24T06:17:05","revision":"0","sha1sum":"03b30c1436225d31512082773371c48d4c5b31ff","size":"3MB","target_guids":["002340a5-4500-3147-3830-304a45484d44"],"type_of_change":"1","version":"HPD6"}],"id":{"product":"8160f18bf46a4d4bb912b9b35f631323","version":"5b11a35d077f4aaf8227c9424906bfca"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG1800JEHMD Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EG1800JEHMDドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG1800JEHMD","target_guid":"002340a5-4500-3147-3830-304a45484d44","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T08:27:23","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG1800JEHMD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel and Mezzanine Host Bus Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"532262","datemodified":"2021-08-26T08:14:14","file_list":["./etc/depmod.d/lpfc.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/elx-lpfc","./lib/modules/3.10.0-1160.el7.x86_64/extra/elx-lpfc/lpfc.ko","./usr/share/smartupdate/kmod-elx-lpfc/component.xml"],"md5sum":"7b215186c8c7c9090019fad97dea2515","name":"kmod-elx-lpfc-12.8.528.7-1.rhel7u9.x86_64.rpm","release":"2021-08-26T08:06:04","revision":"0","sha1sum":"3a1587dadad8222c1b97437e7ec7a2fe30c58cd9","size":"519KB","target_guids":[],"type_of_change":"1","version":"12.8.528.7"}],"id":{"product":"e92933fc6e3845a092aa3adf78ffd145","version":"6b0c1b37f712443ebae8e33a916ef319"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-elx-lpfc-12.8.509.3-1.rhel8u4.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Red Hat Enterprise Linux 7 Update 9 Server Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters and Mezzanine Host Bus Adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"F100","subven":"10DF","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T10:36:09","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to driver version 12.8.528.7</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"kmod-elx-lpfc","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000GEQNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPFCGB.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304745514e48","Version":"HPGB"},{"DeviceName":"MB6000GEQNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPFCGB.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745514e4b","Version":"HPGB"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB4000GEQNH and MB6000GEQNK"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MB4000GEQNHおよびMB6000GEQNK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB4000GEQNH and MB6000GEQNK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGB<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG7</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.&nbsp;This issue was found during supplier ongoing reliability testing.</p>\n\t</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5615477","datemodified":"2021-07-23T07:19:19","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc95f0628-HPGB-9.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc95f0628-HPGB-9.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc95f0628-HPGB-9.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc95f0628-HPGB-9.1/CP048162.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc95f0628-HPGB-9.1/HAKPFCGB.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc95f0628-HPGB-9.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc95f0628-HPGB-9.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc95f0628-HPGB-9.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc95f0628-HPGB-9.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048162.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048162.scexe"],"md5sum":"efedb130e8babe3784a174c86ae62494","name":"firmware-hdd-bfc95f0628-HPGB-9.1.x86_64.rpm","release":"2021-07-23T07:07:19","revision":"0","sha1sum":"7cd6863a9460d12d70551676a7af3ed8a1e9ce5d","size":"5MB","target_guids":["002340a5-4d00-3442-3030-304745514e48","002340a5-4d00-3642-3030-304745514e4b"],"type_of_change":"2","version":"HPGB"}],"id":{"product":"197f33c3224544b3a3519e65de72192d","version":"7e21abe85bb14fada1f6bf4dac02bb56"},"installation":{"command":"CP040269.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB4000GEQNH and MB6000GEQNK Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB4000GEQNHおよびMB6000GEQNKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB4000GEQNH","target_guid":"002340a5-4d00-3442-3030-304745514e48","type":"sata"},{"id":"MB6000GEQNK","target_guid":"002340a5-4d00-3642-3030-304745514e4b","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T19:14:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was found during supplier ongoing reliability testing.</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was found during supplier ongoing reliability testing.</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000GEQNH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB6000GEQNK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GWDFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEAHasseFG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304757444645","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB012000GWDFE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB012000GWDFE Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"4191264","datemodified":"2021-07-23T11:18:05","file_list":["cp048673.xml","cpqsetup.exe","HLEAHasseFG3.rel","payload.json","setup.dll"],"md5sum":"ba5076f876154087abbed978bcd8a385","name":"cp048673.exe","release":"2021-07-23T11:09:05","revision":"0","sha1sum":"64ea822107011bf96b3a5c47af89efbb187877f5","size":"3MB","target_guids":["4d2340a5-3042-3231-3030-304757444645"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"230d4b31fe374aebb4d538e99b933aee","version":"a42128dbe6134e72a7772d3d46773556"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB012000GWDFE Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB012000GWDFEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB012000GWDFE","target_guid":"4d2340a5-3042-3231-3030-304757444645","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-17T08:38:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB012000GWDFE","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWJNP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ND4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e50","Version":"HPD4"},{"DeviceName":"EG001200JWJNQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ND4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e51","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG000600JWJNP and EG001200JWJNQ"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EG000600JWJNPおよびEG001200JWJNQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG000600JWJNP and EG001200JWJNQ&nbsp;Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"5948414","datemodified":"2021-07-23T08:36:07","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD4-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD4-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD4-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD4-2.1/CP048065.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD4-2.1/SSKYBT512ND4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD4-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD4-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD4-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD4-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048065.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048065.scexe"],"md5sum":"dbc7026b213245a3d8922faa225f4459","name":"firmware-hdd-bdfb8e99d9-HPD4-2.1.x86_64.rpm","release":"2021-07-23T08:23:06","revision":"0","sha1sum":"2eceb3bcd1083873e4131551b3e5855d09878628","size":"5MB","target_guids":["452340a5-3047-3030-3630-304a574a4e50","452340a5-3047-3130-3230-304a574a4e51"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"73ec3bde4c824e4abd7a12e09eb4bcb4","version":"a34900e116ac44bd9af7cab566071acb"},"installation":{"command":"CP041693.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64)  - EG000600JWJNP and EG001200JWJNQ Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - EG000600JWJNPおよびEG001200JWJNQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EG001200JWJNQ","target_guid":"452340a5-3047-3130-3230-304a574a4e51","type":"sas"},{"id":"EG000600JWJNP","target_guid":"452340a5-3047-3030-3630-304a574a4e50","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-21T11:08:09","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001200JWJNQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG000600JWJNP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWRTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLPeAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57525444","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB008000JWRTD"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB008000JWRTD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB008000JWRTD Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD1<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"6016440","datemodified":"2021-07-23T08:02:25","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-2.1/CP048134.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-2.1/HVLPeAsseFD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048134.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048134.scexe"],"md5sum":"44528759ed2a0980b849016d45f36bde","name":"firmware-hdd-8b26d1ef02-HPD2-2.1.x86_64.rpm","release":"2021-07-23T07:50:08","revision":"0","sha1sum":"ddc7c8fb78a258a6ce934bd65346fbc85d56a2e4","size":"5MB","target_guids":["4d2340a5-3042-3830-3030-304a57525444"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"596340d3247946aaa109faeb065a7eab","version":"8468aed0707544adbb9b82ce9c980bda"},"installation":{"command":"CP041479.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB008000JWRTD Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) -  MB008000JWRTD ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB008000JWRTD","target_guid":"4d2340a5-3042-3830-3030-304a57525444","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-26T11:48:37","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000JWRTD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000JVYYV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMPN6SD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a56595956","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB6000JVYYV"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： MB6000JVYYV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB6000JVYYV&nbsp;Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><br />\n<strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5555260","datemodified":"2021-07-23T07:44:40","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-0595c2a887-HPD2-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-0595c2a887-HPD2-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-0595c2a887-HPD2-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-0595c2a887-HPD2-8.1/CP048172.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-0595c2a887-HPD2-8.1/SMPN6SD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-0595c2a887-HPD2-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-0595c2a887-HPD2-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-0595c2a887-HPD2-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-0595c2a887-HPD2-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048172.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048172.scexe"],"md5sum":"f8150396d7023267727c4b4e7166b754","name":"firmware-hdd-0595c2a887-HPD2-8.1.x86_64.rpm","release":"2021-07-23T07:32:06","revision":"0","sha1sum":"df7567ddebd7f84b06936735375c4f53666294ee","size":"5MB","target_guids":["002340a5-4d00-3642-3030-304a56595956"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"2dc381cd01314b3ba2f24f5b5647b2a3","version":"59f6378837854cf7b31399705a702008"},"installation":{"command":"CP040307.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB6000JVYYV Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB6000JVYYVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB6000JVYYV","target_guid":"002340a5-4d00-3642-3030-304a56595956","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T19:57:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000JVYYV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXL5800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3830-3048d90154e8","Version":"MPK75H5Q"},{"DeviceName":"MZXL51T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3154-36487a9b1618","Version":"MPK75H5Q"},{"DeviceName":"MZXL53T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3354-324884d9e9f5","Version":"MPK75H5Q"},{"DeviceName":"MZXL56T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3654-34482ab7fb8f","Version":"MPK75H5Q"},{"DeviceName":"MZXL5960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3936-304894dc03d2","Version":"MPK75H5Q"},{"DeviceName":"MZXL51T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3154-3948e450274f","Version":"MPK75H5Q"},{"DeviceName":"MZXL53T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3354-38483310a47b","Version":"MPK75H5Q"},{"DeviceName":"MZXL57T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3754-364820f1a5c1","Version":"MPK75H5Q"},{"DeviceName":"MZXL515THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3135-54486d0092b3","Version":"MPK75H5Q"},{"DeviceName":"MZXL512THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3132-544895b51a17","Version":"MPK75H5Q"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-00H3"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MZXL5800HBHQ-000H3、MZXL51T6HBJR-000H3、MZXL53T2HBLS-000H3、MZXL56T4HALA-000H3、MZXL512THALA-000H3、MZXL5960HBHQ-000H3、MZXL51T9HBJR-000H3、MZXL51T9HBJR-000H3、MZXL53"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for&nbsp;VMware ESXi - &nbsp;MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-00H3 Drive<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;&nbsp;MPK75H5Q</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; MPK73H5Q</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; MPK73H5Q</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li style=\"margin-left: 0px; margin-right: 0px; text-align: left;\">Added support for VMware 7.0 U3</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Fixed False UECC issue at idle power mode (12.8TB and 15.36TB only).</li>\n\t<li>Apply PCLK running PHY option, PLL clock disable can be avoided in lane 0 missing case.</li>\n\t<li>Old FW download Blocking.</li>\n\t<li>FW is changed off the option of TX data alignment for each lane.</li>\n\t<li>FW is changed to clear the interrupt after TLP Complete when PCIe config read operation.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us\" style=\"color: rgb(5, 99, 193); text-decoration: underline;\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us</a></li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>\n"}],"files":[{"bytes":"25527034","datemodified":"2021-08-27T07:12:22","file_list":["/CP048456_BUILD_3.data","/CP048456.vmexe","/CP048456.vmexe64","/CP048456.vmfile","/CP048456_VMw.zip","/CP048456.xml","/payload.json","/CP048456_VMw.zip/index.xml","/CP048456_VMw.zip/vendor-index.xml","/CP048456_VMw.zip/metadata.zip","/CP048456_VMw.zip/vib20/CP048456/HPE_bootbank_CP048456_MPK75H5Q.3-7.0.0.15843807.vib","/CP048456_VMw.zip/metadata.zip/vendor-index.xml","/CP048456_VMw.zip/metadata.zip/vmware.xml","/CP048456_VMw.zip/metadata.zip/vibs/CP048456--8892620352000752534.xml","/CP048456_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048456_MPK75H5Q.3-7.0.0.15843807.xml"],"md5sum":"8cd1462d76598671e5f6a57c8676b359","name":"CP048456.zip","release":"2021-08-27T07:06:47","revision":"0","sha1sum":"d7304a54e30e5f056c488597904d2dd9bd5aca6e","size":"24MB","target_guids":["4d2340a5-585a-354c-3830-3048d90154e8","4d2340a5-585a-354c-3154-36487a9b1618","4d2340a5-585a-354c-3354-324884d9e9f5","4d2340a5-585a-354c-3654-34482ab7fb8f","4d2340a5-585a-354c-3936-304894dc03d2","4d2340a5-585a-354c-3154-3948e450274f","4d2340a5-585a-354c-3354-38483310a47b","4d2340a5-585a-354c-3754-364820f1a5c1","4d2340a5-585a-354c-3135-54486d0092b3","4d2340a5-585a-354c-3132-544895b51a17"],"type_of_change":"2","version":"MPK75H5Q","vib_list":[{"name":"CP048456","version":"MPK75H5Q.3-7.0.0.15843807"}]}],"id":{"product":"6a808075e9fa4bc19e7d11fd17511784","version":"d06603b0a5e04897a9cf276e2a6a5b21"},"installation":{"command":"CP042960.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-00H3 Drive"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - MZXL5800HBHQ-000H3、 MZXL51T6HBJR-000H3、MZXL53T2HBLS-000H3、MZXL56T4HALA-000H3、MZXL512THALA-000H3、 MZXL5960HBHQ-000H3、MZXL51T9HBJR-000H3、MZXL53T8HBLS-000H3、MZXL57T6HALA-000H3および MZXL515THALA-00H3ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MZXL515THALA-000H3","target_guid":"4d2340a5-585a-354c-3135-54486d0092b3","type":"nvme"},{"id":"MZXL512THALA-000H3","target_guid":"4d2340a5-585a-354c-3132-544895b51a17","type":"nvme"},{"id":"MZXL57T6HALA-000H3","target_guid":"4d2340a5-585a-354c-3754-364820f1a5c1","type":"nvme"},{"id":"MZXL56T4HALA-000H3","target_guid":"4d2340a5-585a-354c-3654-34482ab7fb8f","type":"nvme"},{"id":"MZXL53T8HBLS-000H3","target_guid":"4d2340a5-585a-354c-3354-38483310a47b","type":"nvme"},{"id":"MZXL53T2HBLS-000H3","target_guid":"4d2340a5-585a-354c-3354-324884d9e9f5","type":"nvme"},{"id":"MZXL51T6HBJR-000H3","target_guid":"4d2340a5-585a-354c-3154-36487a9b1618","type":"nvme"},{"id":"MZXL5800HBHQ-000H3","target_guid":"4d2340a5-585a-354c-3830-3048d90154e8","type":"nvme"},{"id":"MZXL51T9HBJR-000H3","target_guid":"4d2340a5-585a-354c-3154-3948e450274f","type":"nvme"},{"id":"MZXL5960HBHQ-000H3","target_guid":"4d2340a5-585a-354c-3936-304894dc03d2","type":"nvme"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T08:54:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Fixed False UECC issue at idle power mode (12.8TB and 15.36TB only).</li>\n\t<li>Apply PCLK running PHY option, PLL clock disable can be avoided in lane 0 missing case.</li>\n\t<li>Old FW download Blocking.</li>\n\t<li>FW is changed off the option of TX data alignment for each lane.</li>\n\t<li>FW is changed to clear the interrupt after TLP Complete when PCIe config read operation.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us\" style=\"color: rgb(5, 99, 193); text-decoration: underline;\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us</a></li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Fixed False UECC issue at idle power mode (12.8TB and 15.36TB only).</li>\n\t<li>Apply PCLK running PHY option, PLL clock disable can be avoided in lane 0 missing case.</li>\n\t<li>Old FW download Blocking.</li>\n\t<li>FW is changed off the option of TX data alignment for each lane.</li>\n\t<li>FW is changed to clear the interrupt after TLP Complete when PCIe config read operation.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us\" style=\"color: rgb(5, 99, 193); text-decoration: underline;\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MZXL512THALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL5800HBHQ-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL57T6HALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL53T2HBLS-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL5960HBHQ-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL53T8HBLS-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL56T4HALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL515THALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL51T6HBJR-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL51T9HBJR-000H3","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWCFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757434645","Version":"HPG3"},{"DeviceName":"VK000960GWCFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757434646","Version":"HPG3"},{"DeviceName":"VK000240GWCFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757434644","Version":"HPG3"},{"DeviceName":"VK001920GWCFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757434648","Version":"HPG3"},{"DeviceName":"VK003840GWCFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-30475743464b","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK000240GWCFD, VK000480GWCFE, VK000960GWCFF, VK001920GWCFH and VK003840GWCFK Drives"},{"lang":"ja","x_late":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VK000240GWCFD、VK000480GWCFE、VK000960GWCFF、VK001920GWCFHおよびVK003840GWCFKドライブ。"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for&nbsp;Linux&nbsp;(x64) -&nbsp;VK000240GWCFD, VK000480GWCFE, VK000960GWCFF, VK001920GWCFH and VK003840GWCFK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br />\n<br />\n<strong>Enhancements/New Features:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&bull;&nbsp;&nbsp; Added support for RHEL 8.4 and SLES15SP3.</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None&nbsp;&nbsp;</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4664174","datemodified":"2021-07-23T08:47:27","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-f42438de3d-HPG3-7.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-f42438de3d-HPG3-7.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-f42438de3d-HPG3-7.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-f42438de3d-HPG3-7.1/CP048186.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-f42438de3d-HPG3-7.1/GP863aG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-f42438de3d-HPG3-7.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-f42438de3d-HPG3-7.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-f42438de3d-HPG3-7.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-f42438de3d-HPG3-7.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048186.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048186.scexe"],"md5sum":"c158ca816de427a3b551394e0a7b2dd0","name":"firmware-hdd-f42438de3d-HPG3-7.1.x86_64.rpm","release":"2021-07-23T08:34:09","revision":"0","sha1sum":"382cd2dcb8cbd108513ee4d3adc732737ae6f68b","size":"4MB","target_guids":["562340a5-304b-3030-3438-304757434645","562340a5-304b-3030-3936-304757434646","562340a5-304b-3030-3234-304757434644","562340a5-304b-3130-3932-304757434648","562340a5-304b-3330-3834-30475743464b"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"dee0352e8d5a4157b5757fd1a1669bb8","version":"973868c2b7354caea45f113c8509c4a0"},"installation":{"command":"CP040346.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK000240GWCFD, VK000480GWCFE, VK000960GWCFF, VK001920GWCFH and VK003840GWCFK Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VK000240GWCFD、VK000480GWCFE、VK000960GWCFF、VK001920GWCFHおよびVK003840GWCFKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VK003840GWCFK","target_guid":"562340a5-304b-3330-3834-30475743464b","type":"sata"},{"id":"VK001920GWCFH","target_guid":"562340a5-304b-3130-3932-304757434648","type":"sata"},{"id":"VK000960GWCFF","target_guid":"562340a5-304b-3030-3936-304757434646","type":"sata"},{"id":"VK000480GWCFE","target_guid":"562340a5-304b-3030-3438-304757434645","type":"sata"},{"id":"VK000240GWCFD","target_guid":"562340a5-304b-3030-3234-304757434644","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T20:57:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK001920GWCFH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWCFF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWCFD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWCFE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GWCFK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Intel ixn 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2016."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Microsoft Windows Server 2016で動作しているHPE Intel ixn 10 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"1147928","datemodified":"2020-06-02T18:31:07","file_list":["cp042028.xml","cpqsetup.exe","cp_data.xml","install.xml","ixn65x64.cat","ixn65x64.din","ixn65x64.inf","ixn65x64.sys","ixnmsg.dll","NicCo5.dll","nicdrvr.dll","NicInIXN.dll"],"md5sum":"7f879ff36f92c7ca950dbb968753f837","name":"cp042028.exe","release":"2020-06-02T18:17:25","revision":"0","sha1sum":"c46fd80ff3b27dc40f7133bba49d137716c95cb2","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec8a51872f"],"type_of_change":"0","version":"4.1.199.0"}],"id":{"product":"d7031a8852f2411096f049c632e0a499","version":"7cbc4402f8ac416295139293310220ee"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel ixn Driver for Windows Server 2016"},{"lang":"ja","x_late":"HPE Intel ixnドライバー for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-05-19T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now remove&nbsp;supports Synergy and Blade&nbsp;Server.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product contains Windows system update supported improvements.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"ixn65x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000300JWSJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEn0HPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57534a50","Version":"HPD4"},{"DeviceName":"EG000600JWJNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEn0HPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e48","Version":"HPD4"},{"DeviceName":"EG001200JWJNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEn0HPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e4b","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG000300JWSJP, EG000600JWJNH and EG001200JWJNK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"4842025","datemodified":"2021-07-26T19:36:50","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD4-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD4-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD4-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD4-2.1/CP049142.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD4-2.1/TA15SEn0HPD4.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD4-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD4-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD4-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD4-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049142.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049142.scexe"],"md5sum":"d14dd5e462e8e5a2b7cbca7e5e22a661","name":"firmware-hdd-24fe569b72-HPD4-2.1.x86_64.rpm","release":"2021-07-26T19:24:06","revision":"0","sha1sum":"6643776eeeba11e2c2bea2b2b9ed753a302b67f6","size":"4MB","target_guids":["452340a5-3047-3030-3330-304a57534a50","452340a5-3047-3030-3630-304a574a4e48","452340a5-3047-3130-3230-304a574a4e4b"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"779f4f17fec64b6b9acf9ede668fc68a","version":"63d254a100c84426b38e473ccd1eb24c"},"installation":{"command":"CP041564.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP.&lt;nnnnnn&gt;scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://www.hp.com/swpublishing/MTX-357c87ee9b054ad7a631d9eaba\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EG001200JWJNK","target_guid":"452340a5-3047-3130-3230-304a574a4e4b","type":"sas"},{"id":"EG000600JWJNH","target_guid":"452340a5-3047-3030-3630-304a574a4e48","type":"sas"},{"id":"EG000300JWSJP","target_guid":"452340a5-3047-3030-3330-304a57534a50","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T19:14:58","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001200JWJNK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG000600JWJNH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG000300JWSJP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO1920JEUQQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSCPPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314f-3932-304a45555151","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models:VO1920JEUQQ"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、ドライブモデル：VO1920JEUQQのファームウェアを提供します"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VO1920JEUQQ Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong>&nbsp;&nbsp;&nbsp;&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp; None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5210912","datemodified":"2021-07-23T09:05:20","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-5d9e841607-HPD3-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-5d9e841607-HPD3-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-5d9e841607-HPD3-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-5d9e841607-HPD3-8.1/CP048196.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-5d9e841607-HPD3-8.1/HSCPPCD3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-5d9e841607-HPD3-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-5d9e841607-HPD3-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-5d9e841607-HPD3-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-5d9e841607-HPD3-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048196.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048196.scexe"],"md5sum":"5ffe61f150e24c778e8d470d6b9f135a","name":"firmware-hdd-5d9e841607-HPD3-8.1.x86_64.rpm","release":"2021-07-23T08:52:12","revision":"0","sha1sum":"1f3fd43d03e9f54f95394591cf7967c05a9ee693","size":"4MB","target_guids":["002340a5-5600-314f-3932-304a45555151"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"5c979876c84d42aba65fe31d9aa00e1f","version":"e795c5cb9ce040dd85e3022caa264bb0"},"installation":{"command":"CP040312.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VO1920JEUQQ Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VO1920JEUQQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VO1920JEUQQ","target_guid":"002340a5-5600-314f-3932-304a45555151","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T10:44:58","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO1920JEUQQ","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware for mezzanine Converged Network adapters."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"12898363","datemodified":"2021-08-25T11:49:22","file_list":["/CP048525_BUILD_6.data","/CP048525.vmexe","/CP048525.vmexe64","/CP048525.vmfile","/CP048525_VMw.zip","/CP048525.xml","/payload.json","/CP048525_VMw.zip/index.xml","/CP048525_VMw.zip/vendor-index.xml","/CP048525_VMw.zip/metadata.zip","/CP048525_VMw.zip/vib20/CP048525/HPE_bootbank_CP048525_2021.10.01.6-6.7.0.7535516.vib","/CP048525_VMw.zip/metadata.zip/vendor-index.xml","/CP048525_VMw.zip/metadata.zip/vmware.xml","/CP048525_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048525_2021.10.01.6-6.7.0.7535516.xml","/CP048525_VMw.zip/metadata.zip/vibs/CP048525--2688699759288500292.xml"],"md5sum":"53a5fa96c0a26ce952a04800a0cdad08","name":"CP048525.zip","release":"2021-08-25T11:43:05","revision":"0","sha1sum":"ec12d301254d914e389ffe187fd357aaafa3f001","size":"12MB","target_guids":[],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"CP048525","version":"2021.10.01.6-6.7.0.7535516"}]}],"id":{"product":"473337ce981645a68e8aac7c8197322d","version":"678bf946a8cc4645861b2fa7cd24e50a"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the&nbsp;Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, <strong>if the component is supported by SUM but is not yet part of an SPP:</strong></strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Firmware Flash for Emulex Mezzanine Converged Network Adapters for VMware vSphere  6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"20000"},"supported_devices":[{"dev":"0724","subdev":"1935","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1935","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1934","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"1934","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T10:38:33","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p dir=\"LTR\">Updated CNA (XE100 series) firmware</p>\n\n<p dir=\"LTR\">This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 20Gb 2-port 650FLB Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1345.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 20Gb 2-port 650M Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1345.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"emulex_cna","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Blade Intel ixn 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2016."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Microsoft Windows Server 2016で動作しているHPE Blade Intel ixn 10 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1212736","datemodified":"2020-12-02T16:16:13","file_list":["cp045176.xml","cpqsetup.exe","cp_data.xml","install.xml","ixn65x64.cat","ixn65x64.din","ixn65x64.inf","ixn65x64.sys","ixnmsg.dll","nicco4.dll","NicCo5.dll","nicdrvr.dll","NicInIXN.dll"],"md5sum":"b055f1cd42190cb6b23134bb7415aed5","name":"cp045176.exe","release":"2020-12-02T15:59:22","revision":"0","sha1sum":"70686ff56e186a30c1c78a8ad24ce0de0d105edc","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec8a51872f"],"type_of_change":"0","version":"4.1.199.0"}],"id":{"product":"1ba8b21e9855422b82a9a544b83e660c","version":"189458f390f640e7815970da71a7de27"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Intel ixn Driver for Windows Server 2016"},{"lang":"ja","x_late":"HPE Blade Intel ixnドライバー for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product is updated to maintain compatibility with updated Windows installation libraries, ixtmsg.dll, nicco5.dll, and nicinitx.dll.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"ixn65x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component contains Emulex Storport driver for Extended Systems which provides Fibre Channel over Ethernet-mezzanine Host Bus Adapter driver support for HPE Storage RAID Arrays."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"2039120","datemodified":"2021-08-27T05:57:51","file_list":["brcmdrvr-fcoe-12.0.1192.0-21.exe","cp048530.xml","cpqsetup.exe","ElxCNAInstaller.dll","install.xml","SysConfig.frm","SysConfig.frm.ja"],"md5sum":"da148047aa4f3f22bf3ff88faa1bdc66","name":"cp048530.exe","release":"2021-08-27T05:54:06","revision":"0","sha1sum":"49c95dbc6d8a6b75cd609fad61582010f323dbe5","size":"1MB","target_guids":[],"type_of_change":"1","version":"12.0.1192.0"}],"id":{"product":"5918dbac39314f7dbb116fba325b1ea7","version":"c6b6d53b4057441c8304bf9371eabbf3"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>&nbsp;</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation.</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Storage mezzanine Fibre Channel Over Ethernet Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2012R2/2016"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1934","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1935","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"1934","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"1935","subven":"103C","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T10:38:41","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p style=\"margin-left:0in; margin-right:0in\">Updated to driver version 12.0.1192.0</p>\n\n<p>&nbsp;</p>\n\n<p>Removed the raw driver file folder.&nbsp; The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:<br />\n<br />\n&nbsp;&nbsp;&nbsp; brcmdrvr-fcoe-version.exe /q2 extract=2<br />\n<br />\nThe extracted files are located:<br />\n<br />\n&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Broadcom\\Drivers\\FCoE-version<br />\n<br />\nEach kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,<br />\n<br />\n&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Broadcom\\Drivers\\FCoE-version\\x64\\win2012</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"elxcna.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"},{"name":"elxcna.sys","sw_key_expectedpath":"%programfiles%\\Broadcom\\AutoPilot Installer\\FCoE\\Drivers\\Storport\\x64\\Win2016"},{"name":"elxcna.sys","sw_key_expectedpath":"%programfiles%\\Broadcom\\AutoPilot Installer\\FCoE\\Drivers\\Storport\\x64\\Win2012R2"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"HPE Insight Management Agents help IT administrators rapidly respond to potential and actual system failures, increase system stability, reduce troubleshooting complexity, and minimize downtime by providing predictive fault management."},{"lang":"ja","x_late":"HPE Insightマネジメントエージェントを使用すると、障害予測管理が実現されるので、IT管理者は、潜在的および実際のシステム障害に迅速に対応し、システムの安定性を強化し、トラブルシューティングの複雑さを軽減し、ダウン時間を最小限に抑えることができます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[],"files":[{"bytes":"19647376","datemodified":"2021-02-26T08:23:49","file_list":["agents_x64.msi","agntinst.dll","cp041529.xml","cpqmghost_cfg_en.xml","cpqmghost_cfg_ja.xml","cpqsetup.exe","cp_data.xml","cqmghost_cfg.en","cqmghost_cfg.ja","install.xml","vc110rtl-x64-release.msi","vc90sp1rtl-x64-release.msi"],"md5sum":"d78976b462a87cdd73ad03aff6e1450f","name":"cp041529.exe","release":"2021-04-28T00:00:00","revision":"1","sha1sum":"e0e0a3fa69986cee74af7f0513e38fbd4d40745a","size":"18MB","target_guids":[],"type_of_change":"0","version":"11.1.0.0"}],"id":{"product":"C8627","version":"2befeb38cce44ea1b85d5cacfef1aa85"},"installation":{"command":"cpqsetup.exe","command_params":"/verbose_log","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 3/4 Management Controller Driver Package for Windows (Gen 7 or later)","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb0c60beb","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 3/4 Management Controller Driver Package for Windows (Gen 7 or later)"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 2 Management Controller Driver for Windows (G6 or earlier)","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2c83f673","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 2 Management Controller Driver for Windows (G6 or earlier)"}]},{"ListConditional":"AND","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP System Management Homepage for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1b3359b0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP System Management Homepage for Windows"},{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant PCI Hot Plug Controller Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca134477","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant PCI Hot Plug Controller Driver for Windows"},{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Remote Insight Board Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d6a8690","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Remote Insight Board Driver for Windows"},{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca9ecb0f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Remote Insight Lights-Out II Board Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec043b810e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Remote Insight Lights-Out II Board Driver for Windows"},{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Rack Infrastructure Interface Service for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3c85d0a3","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Rack Infrastructure Interface Service for Windows"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"snmp Service","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb317c36a","ServerModel":["*"],"Target_guids":[],"Type":"EQ","Version":"*","description":"snmp Service"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC31xx Fast Ethernet NIC Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec0458ccd6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC31xx Fast Ethernet NIC Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Intel Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec29a79e49","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Intel Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Broadcom Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec83d2dd89","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Broadcom Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Broadcom Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec8b37898c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Broadcom Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Multifunction Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec82a27969","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Multifunction Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC51xx NetXen Multifunction Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecc2ac73ef","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC51xx NetXen Multifunction Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC52xx NetXen Multifunction Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec7bc999f9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC52xx NetXen Multifunction Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Intel Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6e1a64e9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Intel Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Intel N1E Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec86615221","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Intel N1E Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Broadcom 1Gb Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec09e99f10","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Broadcom 1Gb Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Broadcom 1Gb Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe73cc6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Broadcom 1Gb Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Intel Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec76564025","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Intel Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Broadcom Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec431d2047","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Broadcom Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Broadcom Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbbd7533a","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Broadcom Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Multifunction Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd765f4f8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Multifunction Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Intel N1E Driver for Windows x64 Editions","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec99544f42","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Intel N1E Driver for Windows x64 Editions"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC51xx NetXen Multifunction Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec10a1b876","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC51xx NetXen Multifunction Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC52xx NetXen Multifunction Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf2c2c1fe","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC52xx NetXen Multifunction Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Intel Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca203699c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Intel Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Intel N1E Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec9814091f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Intel N1E Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Intel N1E Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec013cb3c5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Intel N1E Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Broadcom 1Gb Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4efaf7b6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Broadcom 1Gb Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Broadcom 1Gb Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3f40450a","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Broadcom 1Gb Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Broadcom 10GbE Multifunction Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecba1ae635","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Broadcom 10GbE Multifunction Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Broadcom 10GbE Multifunction Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec9bc6b74c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Broadcom 10GbE Multifunction Driver for Windows"}]}]}]},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number. From that drive and directory, execute the downloaded file. Click the \"Install\" button to proceed with the installation. The agents will automatically be installed."},{"lang":"ja","x_late":"スマート コンポーネントをハードディスク ドライブにダウンロードし、そのディレクトリに移動します。 ダウンロードしたファイルは、スマート コンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。 そのドライブ、ディレクトリから、ダウンロードしたファイルを実行します。 インストール ボタンをクリックして、インストールを開始します。 エージェントは自動的にインストールされます。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Insight Management Agents for Microsoft Windows Server x64 Editions"},{"lang":"ja","x_late":"HPE Insightマネジメントエージェントfor Microsoft Windows Server x64 Edition"}],"prerequisites":{"required_diskspace":{"size_kb":"25000"},"supported_devices":[{"id":"5219994","target_guid":"","type":"other"}],"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-05-29T06:13:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Fixed multiple event ID 1182 issue</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Fixed unusual Windows system events originating from SNMP network agents</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"agentver.dll","sw_key_expectedpath":"%systemroot%\\system32\\cpqmgmt"},{"name":"cpqnimgt.exe","sw_key_expectedpath":"%systemroot%\\system32\\cpqnimgt"},{"name":"cqmgserv.exe","sw_key_expectedpath":"%systemroot%\\system32\\cpqmgmt\\cqmgserv"},{"name":"cqmgstor.exe","sw_key_expectedpath":"%systemroot%\\system32\\cpqmgmt\\cqmgstor"},{"name":"cqmghost.exe","sw_key_expectedpath":"%systemroot%\\system32\\cpqmgmt\\cqmghost"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built\nfor SUSE LINUX Enterprise Server 12 (64-bit) to enable the HPE H2xx SAS/SATA Host Bus Adapter.  This RPM provides a customer friendly approach to install a\npre-built binary driver."},{"lang":"ja","x_late":"このRPMを使用して、HPE H2xx SAS/SATAホストバスアダプターを有効にする、SUSE LINUX Enterrise Server 12（64-bit）用のビルド済みバイナリドライバーモジュールを提供します。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"1063589","datemodified":"2018-12-13T09:12:23","file_list":["./etc/modprobe.d/mpt3sas.conf","./lib/modules/4.12.14-94.37-default","./lib/modules/4.12.14-94.37-default/updates","./lib/modules/4.12.14-94.37-default/updates/mpt2sas.ko","./usr/share/smartupdate/lsi-mpt2sas-kmp-default/component.xml"],"md5sum":"9785557a0564fc9a1ad760f2e1f7799c","name":"lsi-mpt2sas-kmp-default-15.10.09.00-1.sles12sp4.x86_64.rpm","release":"2018-12-13T09:13:08","revision":"0","sha1sum":"cf7146998ba594a8d11b3e8bce01ed70871906bd","size":"1MB","target_guids":[],"type_of_change":"1","version":"15.10.09.00-1"}],"id":{"product":"fbd21bfdc4ac48d1a1f00173d5e23ce2","version":"231836b382694cd5891ddf6311951fb5"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To install the driver, type the following command:<br />\n# rpm -ivh lsi-mpt2sas-kmp-X.X.X.X-X.sles12spN.x86_64.rpm (x.x.x.x-x represents the version numberand N represents the OS Update number)<br />\n<br />\nTo upgrade the driver, type the following command:<br />\n# rpm -Uvh lsi-mpt2sas-kmp-X.X.X.X-X.sles12spN.x86_64.rpm (x.x.x.x-x represents the version number and and N represents the OS Update number)<br />\n<br />\nA REBOOT is required for your computer when the setup is complete.</p>\n\n<p>Note: If HPE System Insight Manager support is required, install the latest Service Pack for ProLiant and<br />\nlsi-mpt2sas-kmp-X.X.X.X-X.sles12spN.x86_64.rpm after the OS has completed its installation process and system has rebooted.</p>\n"},{"lang":"ja","x_late":"<p>ドライバーをインストールするには、次のコマンドを入力します。<br />\n# rpm -ivh lsi-mpt2sas-kmp-X.X.X.X-X.sles12spN.x86_64.rpm (x.x.x.x-xはバージョン番号を、NはOSアップデート番号を表します。)<br />\n<br />\nドライバーをアップグレードするには、次のコマンドを入力します。<br />\n# rpm -Uvh lsi-mpt2sas-kmp-X.X.X.X-X.sles12spN.x86_64.rpm (x.x.x.x-xはバージョン番号を、NはOSアップデート番号を表します。)<br />\n<br />\nセットアップが完了したらコンピュータをリブートする必要があります。</p>\n\n<p>注：HPE System Insight Managerサポートが必要な場合は、OSがインストールを完了してシステムが再起動した後で、ProLiant用の最新のサービスパックおよび<br />\nOSがインストレーションプロセスを完了し、システムがリブートした後で、lsi-mpt2sas-kmp-X.X.X.X-X.sles12spN.x86_64.rpmをインストールします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"LSI Logic Corporation"}],"name":[{"lang":"en","x_late":"HPE H2xx SAS/SATA Host Bus Adapter Driver for SUSE LINUX Enterprise Server 12 (64-bit)"},{"lang":"ja","x_late":"SUSE LINUX Enterrise Server 12（64-bit）用HPE H2xx SAS/SATAバスアダプタードライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0070","subdev":"0046","subven":"1590","target_guid":"","type":"pci","ven":"1000"},{"dev":"0087","subdev":"0044","subven":"1590","target_guid":"","type":"pci","ven":"1000"},{"dev":"0087","subdev":"0042","subven":"1590","target_guid":"","type":"pci","ven":"1000"},{"dev":"0087","subdev":"0043","subven":"1590","target_guid":"","type":"pci","ven":"1000"},{"dev":"0087","subdev":"0041","subven":"1590","target_guid":"","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-11-03T09:10:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Address the Linux Spectre Variant 2 Vulnerability Issue</p>\n"},{"curr_enhancements_x_late":"<p>Added support for&nbsp;SUSE Linux Enterprise Server 12 SP4</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"P81","value":"HP ProLiant DL380p Gen8 SE Server"},{"key":"A31","value":"HP ProLiant SL4545 G7 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"P74","value":"HP ProLiant SL140s Gen8 Server (private)"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"P83","value":"HP ProLiant SL210t Gen8 Server"}],"sw_keys":[{"name":"lsi-mpt2sas-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000GEFQV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGRTG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-304745465156","Version":"HPG8"},{"DeviceName":"MM2000GEFRA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGRTG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-324d-3030-304745465241","Version":"HPG8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MM1000GEFQV and MM2000GEFRA"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MM1000GEFQVおよびMM2000GEFRA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MM1000GEFQV and MM2000GEFRA Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG5<br />\n<br />\n<strong>Previous Version of Firmware:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>HPG5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5474060","datemodified":"2021-07-23T07:47:58","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG8-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG8-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG8-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG8-8.1/CP048179.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG8-8.1/SAVGRTG8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG8-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG8-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG8-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG8-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048179.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048179.scexe"],"md5sum":"eec3b569429e45085b77be9f0dbacc4d","name":"firmware-hdd-ec908c3650-HPG8-8.1.x86_64.rpm","release":"2021-07-23T07:35:06","revision":"0","sha1sum":"37d2baea6c1aaae91ae0c69b25d986517d843f4d","size":"5MB","target_guids":["002340a5-4d00-314d-3030-304745465156","002340a5-4d00-324d-3030-304745465241"],"type_of_change":"1","version":"HPG8"}],"id":{"product":"38437d438933420e8063d6e963ffd91f","version":"b8f0f4a7d0c04f97914b91d00f279aa7"},"installation":{"command":"CP040273.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MM1000GEFQV and MM2000GEFRA Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MM1000GEFQVおよびMM2000GEFRAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MM1000GEFQV","target_guid":"002340a5-4d00-314d-3030-304745465156","type":"sata"},{"id":"MM2000GEFRA","target_guid":"002340a5-4d00-324d-3030-304745465241","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T20:26:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MM1000GEFQV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MM2000GEFRA","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWRTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57525448","Version":"HPD2"},{"DeviceName":"MB012000JWRTF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57525446","Version":"HPD2"},{"DeviceName":"MB010000JWRTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a57525445","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB014000JWRTH, MB012000JWRTF and MB010000JWRTE"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB014000JWRTH、MB012000JWRTFおよびMB010000JWRTE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi&nbsp;- MB014000JWRTH, MB012000JWRTF and MB010000JWRTE&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"18361472","datemodified":"2021-08-26T14:56:07","file_list":["/CP048340_BUILD_2.data","/CP048340.vmexe","/CP048340.vmexe64","/CP048340.vmfile","/CP048340_VMw.zip","/CP048340.xml","/payload.json","/CP048340_VMw.zip/index.xml","/CP048340_VMw.zip/vendor-index.xml","/CP048340_VMw.zip/metadata.zip","/CP048340_VMw.zip/vib20/CP048340/HPE_bootbank_CP048340_HPD2.2-7.0.0.15843807.vib","/CP048340_VMw.zip/metadata.zip/vendor-index.xml","/CP048340_VMw.zip/metadata.zip/vmware.xml","/CP048340_VMw.zip/metadata.zip/vibs/CP048340--8227837453782433227.xml","/CP048340_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048340_HPD2.2-7.0.0.15843807.xml"],"md5sum":"97aa8d36e8daa1650cd953210125a29b","name":"CP048340.zip","release":"2021-08-26T14:50:49","revision":"0","sha1sum":"2e41af46517ca5cb0afc0cd594a43eee73728d6e","size":"17MB","target_guids":["4d2340a5-3042-3431-3030-304a57525448","4d2340a5-3042-3231-3030-304a57525446","4d2340a5-3042-3031-3030-304a57525445"],"type_of_change":"1","version":"HPD2","vib_list":[{"name":"CP048340","version":"HPD2.2-7.0.0.15843807"}]}],"id":{"product":"809cff8704ac44759685c033bb7b76d3","version":"a4d487f2ee51444b9486ac8b873a9593"},"installation":{"command":"CP041451.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi -MB014000JWRTH, MB012000JWRTF and MB010000JWRTE Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for ESXi - MB014000JWRTH、MB012000JWRTFおよびMB010000JWRTE ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB014000JWRTH","target_guid":"4d2340a5-3042-3431-3030-304a57525448","type":"sas"},{"id":"MB012000JWRTF","target_guid":"4d2340a5-3042-3231-3030-304a57525446","type":"sas"},{"id":"MB010000JWRTE","target_guid":"4d2340a5-3042-3031-3030-304a57525445","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-06T12:48:07","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB014000JWRTH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB010000JWRTE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB012000JWRTF","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EK000200GWEPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3030-3230-304757455044","Version":"HPG3"},{"DeviceName":"EK000400GWEPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3030-3430-304757455045","Version":"HPG3"},{"DeviceName":"EK000800GWEPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3030-3830-304757455046","Version":"HPG3"},{"DeviceName":"EK001600GWEPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3130-3630-304757455048","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EK000200GWEPD, EK000400GWEPE, EK000800GWEPF and EK001600GWEPH Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EK000200GWEPD、EK000400GWEPE、EK000800GWEPF、およびEK001600GWEPHドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;&nbsp;EK000200GWEPD, EK000400GWEPE, EK000800GWEPF and EK001600GWEPH&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4665473","datemodified":"2021-07-23T10:30:32","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-5bf9355926-HPG3-7.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-5bf9355926-HPG3-7.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-5bf9355926-HPG3-7.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-5bf9355926-HPG3-7.1/CP048091.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-5bf9355926-HPG3-7.1/GS865aG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-5bf9355926-HPG3-7.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-5bf9355926-HPG3-7.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-5bf9355926-HPG3-7.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-5bf9355926-HPG3-7.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048091.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048091.scexe"],"md5sum":"ec06fd11ccc42ebea7b7ff2fb05f2ea5","name":"firmware-hdd-5bf9355926-HPG3-7.1.x86_64.rpm","release":"2021-07-23T10:18:19","revision":"0","sha1sum":"4e0f5c839769025ccacb31c4d8aff98da46e007b","size":"4MB","target_guids":["452340a5-304b-3030-3230-304757455044","452340a5-304b-3030-3430-304757455045","452340a5-304b-3030-3830-304757455046","452340a5-304b-3130-3630-304757455048"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"916fe10c0989454da7fed6ac8080c703","version":"3e2bbcfdfe9f41dd9c2700127c0573fd"},"installation":{"command":"CP040347.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EK000200GWEPD, EK000400GWEPE, EK000800GWEPF and EK001600GWEPH Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - EK000200GWEPD、EK000400GWEPE、EK000800GWEPFおよびEK001600GWEPHドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EK000400GWEPE","target_guid":"452340a5-304b-3030-3430-304757455045","type":"sata"},{"id":"EK000800GWEPF","target_guid":"452340a5-304b-3030-3830-304757455046","type":"sata"},{"id":"EK001600GWEPH","target_guid":"452340a5-304b-3130-3630-304757455048","type":"sata"},{"id":"EK000200GWEPD","target_guid":"452340a5-304b-3030-3230-304757455044","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T11:51:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EK000800GWEPF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"EK000400GWEPE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"EK000200GWEPD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"EK001600GWEPH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager（SUM）と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5959296","datemodified":"2021-05-18T02:58:18","file_list":["P92_2.90_04_29_2021.signed.flash","SignedImageInstaller64.dll","cp047842.xml","cpqsetup.exe","cpqsysio64.sys"],"md5sum":"6aa64b77cd0441cf5c284b3e32662a09","name":"cp047842.exe","release":"2021-05-18T02:41:10","revision":"0","sha1sum":"a3e4538dc46cc47ddab0fa0f4ae54596d19d4964","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021"}],"id":{"product":"bfbca72d042244cd96c184756848a501","version":"d7a44d4acad84c8b9eb367efa236147b"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML350 Gen9 (P92) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant ML350 Gen9（P92）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-05T03:37:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"}],"sw_keys":[{"name":"P92","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000480JWDAR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633LD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3438-304a57444152","Version":"HPD8"},{"DeviceName":"VO000960JWDAT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633LD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304a57444154","Version":"HPD8"},{"DeviceName":"VO001920JWDAU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633LD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304a57444155","Version":"HPD8"},{"DeviceName":"VO003840JWDAV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633LD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304a57444156","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO000480JWDAR, VO000960JWDAT, VO001920JWDAU and VO003840JWDAV"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO000480JWDAR、VO000960JWDAT、VO001920JWDAUおよびVO003840JWDAV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VO000480JWDAR, VO000960JWDAT, VO001920JWDAU and VO003840JWDAV&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5131302","datemodified":"2021-07-23T09:49:02","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-2eb810cdd7-HPD8-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-2eb810cdd7-HPD8-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-2eb810cdd7-HPD8-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2eb810cdd7-HPD8-4.1/CP048213.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-2eb810cdd7-HPD8-4.1/G1633LD8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-2eb810cdd7-HPD8-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2eb810cdd7-HPD8-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-2eb810cdd7-HPD8-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-2eb810cdd7-HPD8-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048213.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048213.scexe"],"md5sum":"504bde4585a1011f00a4bb030ecf0a35","name":"firmware-hdd-2eb810cdd7-HPD8-4.1.x86_64.rpm","release":"2021-07-23T09:35:11","revision":"0","sha1sum":"e726fa0d592fbd59cb626084c028adf02c442a6a","size":"4MB","target_guids":["562340a5-304f-3030-3438-304a57444152","562340a5-304f-3030-3936-304a57444154","562340a5-304f-3130-3932-304a57444155","562340a5-304f-3330-3834-304a57444156"],"type_of_change":"2","version":"HPD8"}],"id":{"product":"a27996e3432942ccb8c76d5fed9fc9b4","version":"78b8caa4c1c14411840275a9cfdbeb87"},"installation":{"command":"CP042627.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート:</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>（.rpm拡張子の付いていないrpmファイル名）を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p>\n\n<ul>\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>追加情報：</strong></p>\n\n<p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を解凍するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するには Service Pack for ProLiant から以下の手順に従ってください:</strong><br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VO000480JWDAR, VO000960JWDAT, VO001920JWDAU and VO003840JWDAV Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64)- VO000480JWDAR、VO000960JWDAT、VO001920JWDAUおよびVO003840JWDAVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VO003840JWDAV","target_guid":"562340a5-304f-3330-3834-304a57444156","type":"sas"},{"id":"VO001920JWDAU","target_guid":"562340a5-304f-3130-3932-304a57444155","type":"sas"},{"id":"VO000960JWDAT","target_guid":"562340a5-304f-3030-3936-304a57444154","type":"sas"},{"id":"VO000480JWDAR","target_guid":"562340a5-304f-3030-3438-304a57444152","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T12:17:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO003840JWDAV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920JWDAU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000480JWDAR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000960JWDAT","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6350954","datemodified":"2021-05-18T03:35:01","file_list":["./usr/lib/i386-linux-gnu/firmware-system-p89-2.90_2021_04_29-1.1","./usr/lib/i386-linux-gnu/firmware-system-p89-2.90_2021_04_29-1.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-system-p89-2.90_2021_04_29-1.1/.setup","./usr/lib/i386-linux-gnu/firmware-system-p89-2.90_2021_04_29-1.1/CP047835.xml","./usr/lib/i386-linux-gnu/firmware-system-p89-2.90_2021_04_29-1.1/P89_2.90_04_29_2021.signed.flash","./usr/lib/i386-linux-gnu/firmware-system-p89-2.90_2021_04_29-1.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-system-p89-2.90_2021_04_29-1.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP047835.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP047835.scexe"],"md5sum":"577b795a2a23479ac1a8cbdf5b8aac89","name":"firmware-system-p89-2.90_2021_04_29-1.1.i386.rpm","release":"2021-05-18T03:25:21","revision":"0","sha1sum":"2597fab7613c89af8ced470ad8a6b25e36f4495b","size":"6MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021"}],"id":{"product":"341b142bb61745f792508954cf786af9","version":"75e3e6e7f3484a39a8bf19fa24b75ba1"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HPE ProLiant Agentless Management Service (<strong>AMS</strong>) and HPE SNMP Agents (<strong>SNMP Agents</strong>) are both running.&nbsp; HPE does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager 8.0.0 or later, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、iLOとの通信ができない場合に失敗します。  これは、HPE ProLiant Agentless Management Service (<strong>AMS</strong>)およびHPE SNMPエージェント(<strong>SNMP Agents</strong>)の両方が実行されているときに発生します。  HPEでは、AMSおよびSNMPエージェントを同時に実行させないことを推奨します。  「iLO device not found」エラーが発生した場合、AMSまたはSNMPエージェントを停止させて、再度フラッシュコンポーネントを実行します。<br />\n<br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を見て下さい。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上のSmart Update Manager 8.0.0以降を使用して実行できます。</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>USB Key Creator Utilityを使用して、HP Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":" Online ROM Flash Component for Linux - HPE ProLiant DL380 Gen9/DL360 Gen9 (P89) Servers"},{"lang":"ja","x_late":" オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant DL380 Gen9/DL360 Gen9（P89）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Oracle Linux 6 (AMD64/EMT64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Oracle Linux 7","platform":"Oracle Enterprise Linux","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-05T02:57:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"}],"sw_keys":[{"name":"P89","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"9300211","languages":[{"lang":"fr","x_late":"Utilitaire - Outils"},{"lang":"en","x_late":"Utility - Tools"},{"lang":"cn","x_late":"实用程序 - 工具"},{"lang":"tw","x_late":"公用程式 ─ 工具"},{"lang":"de","x_late":"Hilfsprogramm - Tools"},{"lang":"ko","x_late":"유틸리티 – 도구"},{"lang":"it","x_late":"Utility - Strumenti"},{"lang":"ja","x_late":"ユーティリティ - ツール"},{"lang":"es","x_late":"Utilidad - Herramientas"}]}],"description":[{"lang":"en","x_late":"This product includes HPONCFG, BOOTCFG, TESTEVENT, CONREP, and the Smart Storage Array Command Line Interface (SSACLI) utilities for configuration of servers. HPONCFG can be used to set up and reconfigure the iLO (Integrated Lights-Out) management controller of a server. BOOTCFG can be used to set up the boot configuration for the server. SSACLI can be used in the configuration of HPE Smart Array controllers and attached storage. The TESTEVENT utility generates test WBEM indication and test SNMP trap. The CONREP Utility enables server hardware configuration capture, set and duplication."},{"lang":"ja","x_late":"この製品には、HPONCFG、BOOTCFG、TESTEVENT、CONREP、およびサーバーを構成するためのSmart Storage Array Command Line Interface (SSACLI)ユーティリティが含まれています。HPONCFGは、サーバーのiLO(Integrated Lights-Out)マネジメントコントローラーの設定、再構成に使用できます。BOOTCFGはサーバーの起動構成を設定するために使用できます。SSACLIは、HPE Smartアレイコントローラーと接続されたストレージの構成に使用できます。TESTEVENTユーティリティはテストWBEMイベントとテストSNMPトラップを作ります。CONREPユーティリティは、サーバーハードウェア構成のキャプチャー、設定、そして複製を可能にします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"13653040","datemodified":"2021-09-14T14:29:55","file_list":["/cp047397.xml","/HPE-Utility-Component_10.8.0.670-26.zip","/HPE-Utility-Component_10.8.0.670-26.zip/index.xml","/HPE-Utility-Component_10.8.0.670-26.zip/vendor-index.xml","/HPE-Utility-Component_10.8.0.670-26.zip/metadata-HPE-Utility-Component_10.8.0.670-26.zip","/HPE-Utility-Component_10.8.0.670-26.zip/ilo_670.10.7.5.2-1OEM.670.0.0.7535516.vib","/HPE-Utility-Component_10.8.0.670-26.zip/hponcfg-6.7.0.5.5-0.18.7535516.vib","/HPE-Utility-Component_10.8.0.670-26.zip/cru_670.6.7.10.14-1OEM.670.0.0.7535516.vib","/HPE-Utility-Component_10.8.0.670-26.zip/MIS_bootbank_hpessacli_5.20.8.0-6.7.0.7535516.oem.vib","/HPE-Utility-Component_10.8.0.670-26.zip/conrep_670.10.8.0.18-6.7.0.7535516.vib","/HPE-Utility-Component_10.8.0.670-26.zip/testevent-6.7.0.02-01.00.12.7535516.vib","/HPE-Utility-Component_10.8.0.670-26.zip/bootcfg-6.7.0.02-06.00.14.7535516.vib","/HPE-Utility-Component_10.8.0.670-26.zip/metadata-HPE-Utility-Component_10.8.0.670-26.zip/vendor-index.xml","/HPE-Utility-Component_10.8.0.670-26.zip/metadata-HPE-Utility-Component_10.8.0.670-26.zip/vmware.xml","/HPE-Utility-Component_10.8.0.670-26.zip/metadata-HPE-Utility-Component_10.8.0.670-26.zip/vibs/ilo-2964936189223017316.xml","/HPE-Utility-Component_10.8.0.670-26.zip/metadata-HPE-Utility-Component_10.8.0.670-26.zip/vibs/hponcfg--6504653738878051635.xml","/HPE-Utility-Component_10.8.0.670-26.zip/metadata-HPE-Utility-Component_10.8.0.670-26.zip/vibs/cru--1581854872647123919.xml","/HPE-Utility-Component_10.8.0.670-26.zip/metadata-HPE-Utility-Component_10.8.0.670-26.zip/vibs/hpessacli-914507910414809621.xml","/HPE-Utility-Component_10.8.0.670-26.zip/metadata-HPE-Utility-Component_10.8.0.670-26.zip/vibs/conrep--7426494458955974697.xml","/HPE-Utility-Component_10.8.0.670-26.zip/metadata-HPE-Utility-Component_10.8.0.670-26.zip/vibs/testevent--7260039959213699592.xml","/HPE-Utility-Component_10.8.0.670-26.zip/metadata-HPE-Utility-Component_10.8.0.670-26.zip/vibs/bootcfg-3356455625267296249.xml","/HPE-Utility-Component_10.8.0.670-26.zip/metadata-HPE-Utility-Component_10.8.0.670-26.zip/bulletins/esxi6.7-util-bundle-10.8.0.670-26.xml"],"md5sum":"47a24ee8312e7ca87308db34fc7e3ac4","name":"cp047397.zip","release":"2021-09-14T14:25:54","revision":"0","sha1sum":"a28140cb4ffb5141e4934f4e8abcfdd05b1af368","size":"13MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","20a6e8e4-bf33-4c71-a6bf-d9ecf25c12c9","20a6e8e4-bf33-4c71-a6bf-d9ec23d0c2b9","20a6e8e4-bf33-4c71-a6bf-d9ec0e2e459f","20a6e8e4-bf33-4c71-a6bf-d9eccecbdbe8","20a6e8e4-bf33-4c71-a6bf-d9ec8013c1b6"],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"ilo","version":"670.10.7.5.2-1OEM.670.0.0.7535516"},{"name":"hponcfg","version":"6.7.0.5.5-0.18.7535516"},{"name":"cru","version":"670.6.7.10.14-1OEM.670.0.0.7535516"},{"name":"hpessacli","version":"5.20.8.0-6.7.0.7535516.oem"},{"name":"conrep","version":"670.10.8.0.18-6.7.0.7535516"},{"name":"testevent","version":"6.7.0.02-01.00.12.7535516"},{"name":"bootcfg","version":"6.7.0.02-06.00.14.7535516"}]}],"id":{"product":"53bb40aec8a14ed088d9afe01e9aba86","version":"8b18ecbffb474b2ba2f28254e9b6c016"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To&nbsp;remotely install&nbsp;this&nbsp;bundle&nbsp; online using the HP Smart Update Manager (HPSUM) from the HP Service Pack for ProLiant (SPP):</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"http://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=8788688&amp;lang=en&amp;cc=us\">HP USB Key Creator Utility</a>.</li>\n\t<li>Copy&nbsp;this component&nbsp;to the directory<em> /SPP20xxxxx/hp/swpackages</em> on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.</li>\n\t<li>Change directories to <em>/hp/swpackages</em> and execute&nbsp;./hpsum.</li>\n\t<li>Select the &quot;next&quot; button.</li>\n\t<li>Click &quot;Add Single Target.&quot;</li>\n\t<li>Enter&nbsp;the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow HP Smart Update Manager&nbsp;instructions&nbsp;to complete the update.</li>\n</ol>\n\n<p><br />\n<strong>To&nbsp;install this bundle using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the component zip file to extract the offline bundle.</li>\n\t<li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li>\n</ol>\n\n<p>Refer to VMware documentation for information on the esxcli commands</p>\n"},{"lang":"ja","x_late":"<p><strong>HP Service Pack for ProLiant (SPP)からHP Smart Update Manager (HPSUM)を使用して、このバンドルをオンラインでリモートインストールするには：</strong></p>\n\n<ol>\n\t<li><a href=\"http://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=8788688&lang=en&cc=us\">HP USB Key Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>このコンポーネントをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。</li>\n\t<li><em>/hp/swpackages</em>にディレクトリを変更し、./hpsumを実行します。</li>\n\t<li>「次へ」ボタンを選択します。</li>\n\t<li>「シングルターゲットの追加」をクリックします。</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>HP Smart Update Managerの手順に従って、アップデートを完了します。</li>\n</ol>\n\n<p><br />\n<strong>VMwareツールを使用して、このバンドルをインストールするには：</strong></p>\n\n<ol>\n\t<li>オフラインバンドルを抽出するために、このコンポーネントのzipファイルを解凍します。</li>\n\t<li>オフラインバンドルをインストールするには、「esxcli」コマンドを実行します。</li>\n</ol>\n\n<p>esxcliコマンドの詳細については、VMwareのドキュメントを参照してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Utilities Bundle Smart Component for ESXi 6.7 "},{"lang":"ja","x_late":"HPE ユーティリティバンドル Smartコンポーネント for ESXi 6.7 "}],"prerequisites":{"required_diskspace":{"size_kb":"100"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-29T07:16:11","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Includes an updated the HPE Smart Storage Administrator CLI&nbsp;(SSACLI).</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>hpessacli</p>\n\n<ul>\n\t<li>Added initial passive SED support.</li>\n\t<li>Added new &quot;unchanged&quot; Drive Write Cache (DWC) policy to the applications.</li>\n\t<li>Added support for discovering and reporting failed drives that are not part of a RAID volume.</li>\n</ul>\n","curr_fixes_x_late":"<p>hpessacli</p>\n\n<ul>\n\t<li>Fixed an issue where the &quot;Turn off&quot; LED operation momentarily turns on all Identify LED.</li>\n\t<li>Fixed an issue where an NVME drive was failed after flashing drive firmware.</li>\n\t<li>Fixed an issue where an operation failure message was observed while deleting a volume with status &ldquo;Not Available&rdquo;.</li>\n\t<li>Fixed an issue that SSAScripting reported incorrect size for some drives greater than 1TB. This did not affect SSACLI.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"ilo:670.10.7.5.2-1OEM.670.0.0.7535516","sw_key_expectedpath":"driver:vmware:zip"},{"name":"cru:670.6.7.10.14-1OEM.670.0.0.7535516","sw_key_expectedpath":"driver:vmware:zip"},{"name":"bootcfg:6.7.0.02-06.00.14.7535516","sw_key_expectedpath":"software:vmware:zip"},{"name":"hpessacli:5.20.8.0-6.7.0.7535516.oem","sw_key_expectedpath":"software:vmware:zip"},{"name":"conrep:670.10.8.0.18-6.7.0.7535516","sw_key_expectedpath":"software:vmware:zip"},{"name":"hponcfg:6.7.0.5.5-0.18.7535516","sw_key_expectedpath":"software:vmware:zip"},{"name":"testevent:6.7.0.02-01.00.12.7535516","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The HPE Agentless Management Service (hp-ams) provides support for HPE Integrated Lights-Out 4 (HPE iLO 4) Embedded Health and Alerting."},{"lang":"ja","x_late":"HPE Agentless Management Service（hp-ams）は、HPE Integrated Lights Out 4（HPE iLO 4）内蔵ヘルスおよびアラートのサポートを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Diagnosing connection issues:</strong></p>\n\n<p>Verify that the HPE iLO 4 is talking to SNMP from a Linux system with net-snmp utilities installed:</p>\n\n<p style=\"margin-left:40px\"><em>snmpwalk -t 60 -v 2c -Ox -c</em> <strong>iLO4_configured_community_string</strong> <strong>iLO4_IP_Address</strong>&nbsp;<em>1.3.6.1.4.1.232.1.1</em></p>\n\n<p>Verify that HPE AMS is operating on the Server:</p>\n\n<p style=\"margin-left:40px\"><em>snmpwalk -t 60 -v 2c -Ox -c</em> <strong>iLO4_configured_community_string</strong> <strong>iLO4_IP_Address</strong>&nbsp;<em>1.3.6.1.4.1.232.5.1</em></p>\n"},{"lang":"ja","x_late":"<p><strong>接続の問題の診断：</strong></p>\n\n<p>HPE iLO 4が、net-snmpユーティリティがインストールされたLinuxシステムから、SNMPに通信していることを確認：</p>\n\n<p style=\"margin-left:40px\"><em>snmpwalk -t 60 -v 2c -Ox -c</em> <strong>iLO4_configured_community_string</strong> <strong>iLO4_IP_Address</strong> <em>1.3.6.1.4.1.232.1.1</em></p>\n\n<p>サーバー上でHPE AMSが動作していることを確認：</p>\n\n<p style=\"margin-left:40px\"><em>snmpwalk -t 60 -v 2c -Ox -c</em> <strong>iLO4_configured_community_string</strong> <strong>iLO4_IP_Address</strong> <em>1.3.6.1.4.1.232.5.1</em></p>\n"}],"files":[{"bytes":"752448","datemodified":"2021-10-06T05:19:01","file_list":["./etc/sysconfig/hp-ams","./opt/hp/hp-ams","./opt/hp/hp-ams/hp-ams.license","./sbin/amsHelper","./usr/lib/systemd/system/hp-ams.service","./usr/share/man/man8/amsHelper.8.gz","./usr/share/smartupdate/hp-ams/component.xml"],"md5sum":"7845dd9e3fb8f5a6f8a71b1db4c2dc68","name":"hp-ams-2.10.4-885.4.rhel7.x86_64.rpm","release":"2021-10-06T05:07:08","revision":"0","sha1sum":"fe904f39af6290e311f88bda473a93efa9e0c63c","size":"734KB","target_guids":[],"type_of_change":"0","version":"2.10.4"}],"id":{"product":"e574ba077b7e40e98fa10de501cd4f19","version":"fb9cc94af2f74624ab838e8e00d7a6e1"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"","SubRequirements":[]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>To install the package type:</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;rpm -ivh hp-ams-&lt;version&gt;.rpm</p>\n\n<p>To check whether the package is loaded properly type:</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;systemctl status hp-ams</p>\n\n<p>Additional help is available by typing:</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;man&nbsp;amshelper</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Red Hat Enterprise Linux 7 伺服器的 HPE ProLiant 無代理管理服務"},{"lang":"en","x_late":"HPE ProLiant Agentless Management Service for Red Hat Enterprise Linux 7 Server"},{"lang":"ko","x_late":"Red Hat Enterprise Linux 7 서버용 HPE ProLiant Agentless 관리 서비스"},{"lang":"cn","x_late":"Red Hat Enterprise Linux 7 Server版HPE ProLiant无代理管理服务"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"id":"5219994","target_guid":"","type":"other"},{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3300","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3302","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-21T13:28:54","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>Addressed&nbsp;a small amount of memory leak as documented in the Customer Advisory, <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00053824en_us\" style=\"color:#0563c1; text-decoration:underline\">a00053824en_us</a></li>\n\t<li>&nbsp;NVMe drive information is now available in the CPQSE.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>Drive&nbsp;status all shows failed on SL4540 Gen8 H220 [LSI] ILO4 due to&nbsp; incorrect SCSI command tags.</li>\n\t<li>Addressed issue where hp-ams may fail to start when&nbsp;U.3 NVMe devices are installed in the system</li>\n\t<li>The HPE Synergy 6810C 25/50Gb Ethernet Adapter not displaying information in hp-ams is now resolved</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"J06","value":"HP ProLiant MicroServer Gen8"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 v2 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P78","value":"HP ProLiant ML310e Gen8 v2 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P88","value":"HP ProLiant ML10 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"}],"sw_keys":[{"name":"hp-ams","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWUDA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEBHasseFG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304757554441","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB014000GWUDA Drive"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB014000GWUDAドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB014000GWUDA Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"6231414","datemodified":"2021-07-23T06:00:04","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG2-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG2-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG2-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG2-5.1/CP048142.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG2-5.1/HLEBHasseFG2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG2-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG2-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG2-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG2-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048142.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048142.scexe"],"md5sum":"0a148a8c97c042ce1988d26e3d01555f","name":"firmware-hdd-41cdb1c9da-HPG2-5.1.x86_64.rpm","release":"2021-07-23T05:48:05","revision":"0","sha1sum":"9b305e83b7c1841887bc0a138d2cb288cf2739ee","size":"5MB","target_guids":["4d2340a5-3042-3431-3030-304757554441"],"type_of_change":"1","version":"HPG2"}],"id":{"product":"fc2945bc3e5744fea9d120a012546560","version":"dc734ac044fa4741be51ceeef8cb5432"},"installation":{"command":"CP041508.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB014000GWUDA Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB014000GWUDAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB014000GWUDA","target_guid":"4d2340a5-3042-3431-3030-304757554441","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-26T18:15:30","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB014000GWUDA","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6882995","datemodified":"2021-05-17T23:55:40","file_list":["/CP047846.vmexe","/CP047846.vmfile","/CP047846.xml","/README.txt"],"md5sum":"e6c112e8030be2a088cb4c4f696e729b","name":"CP047846.zip","release":"2021-05-18T04:52:15","revision":"0","sha1sum":"b2198c873524c490196ca2773b640c3753b09762","size":"6MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021","vib_list":[]}],"id":{"product":"7615104752d44337b92336bf27de44e5","version":"2774f48e0a5c47418dd05da3cb6a66fc"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component requires that the CRU driver be loaded before the component can run.<br />\nThe minimum CRU version for 5.1 is 5.0.3.9.<br />\nThe minimum CRU version for 5.5 is 5.5.4.1.<br />\nThe minimum CRU version for 6.0 is 6.0.8.<br />\nThe minimum CRU version for 6.5 is 6.5.8.<br />\nThe minimum CRU version for 6.7 is 6.7.10.<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>SPP Offline mode boots a special Linux OS environment, thus the Linux Components are used, not the VMware Components</li>\n</ul>\n\n<p><br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Download the appropriate SPP</li>\n\t<li>Add the component to the SPP</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run SUM</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps to complete the firmware update</li>\n\t<li>Refer to the SPP documentation for detailed instructions at:&nbsp; <a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Component ( CPxxxxxx.zip) in a temporary directory</li>\n\t<li>From the same directory, unzip the Component:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>To perform the standalone installation, execute the command:<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>Follow the directions given by the Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system for the firmware update to take effect</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、実行する前にCRUドライバーがロードされている必要があります。<br />\n5.1の最小CRUバージョンは5.0.3.9です。<br />\n5.5の最小CRUバージョンは5.5.4.1です。<br />\n6.0の最小CRUバージョンは6.0.8です。<br />\n6.5の最小CRUバージョンは6.5.8です。<br />\n6.7の最小CRUバージョンは6.7.10です。<br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMwareコンポーネントではなく、Linuxコンポーネントが用いられます</li>\n</ul>\n\n<p><br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします</li>\n\t<li>SPPにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします</li>\n\t<li>SUMを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います</li>\n\t<li>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>コンポーネント (CPxxxxxx.zip)を一時ディレクトリに置きます</li>\n\t<li>同じディレクトリからコンポーネントをunzipします:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>スタンドアロンのインストールを行うために、次のコマンドを実行します：<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>コンポーネントの指示に従います</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n\t<li>システムを再起動し、ファームウェアのアップデートを有効にします</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware - HPE ProLiant ML110 Gen9 (P99) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for VMware - HPE ProLiant ML110 Gen9（P99）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"5","minor":"1","name":"VMware vSphere 5.1","platform":"vmware_esx_server","sr":"OEM"},{"major":"5","minor":"5","name":"VMware vSphere 5.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-05T03:47:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"}],"sw_keys":[{"name":"P99","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWFUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SELD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a57465556","Version":"HPD4"},{"DeviceName":"EG001200JWFVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SELD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3230-304a57465641","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG000600JWFUV and EG001200JWFVA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - EG000600JWFUV and EG001200JWFVA Drives<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"2921688","datemodified":"2021-07-24T07:29:05","file_list":["cp048452.xml","cpqsetup.exe","payload.json","setup.dll","T14SELD4.REL"],"md5sum":"0566462dbfb75a2e3a153405938873c3","name":"cp048452.exe","release":"2021-07-24T07:20:05","revision":"0","sha1sum":"ff668eb70abfe56f34bd539336de285ac01b137e","size":"2MB","target_guids":["452340a5-3047-3030-3630-304a57465556","452340a5-3047-3130-3230-304a57465641"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"62c5be0602154ae6afbf730b5a1cb394","version":"8a5a5206ba2446eea6762ad2acf3860d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG000600JWFUV and EG001200JWFVA Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  EG000600JWFUVおよびEG001200JWFVAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG001200JWFVA","target_guid":"452340a5-3047-3130-3230-304a57465641","type":"sas"},{"id":"EG000600JWFUV","target_guid":"452340a5-3047-3030-3630-304a57465556","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T05:59:29","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>A low-probability, high severity corner case of sustained outer-diameter activity with emergency power off when heads are at the outer diameter prevented heads from parking/latching properly on a few drives in the field.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001200JWFVA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG000600JWFUV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5782721","datemodified":"2021-06-02T02:06:30","file_list":["./usr/lib/i386-linux-gnu/firmware-system-u22-3.00_2021_04_01-1.1","./usr/lib/i386-linux-gnu/firmware-system-u22-3.00_2021_04_01-1.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-system-u22-3.00_2021_04_01-1.1/.setup","./usr/lib/i386-linux-gnu/firmware-system-u22-3.00_2021_04_01-1.1/CP047380.xml","./usr/lib/i386-linux-gnu/firmware-system-u22-3.00_2021_04_01-1.1/U22_3.00_04_01_2021.signed.flash","./usr/lib/i386-linux-gnu/firmware-system-u22-3.00_2021_04_01-1.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-system-u22-3.00_2021_04_01-1.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP047380.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP047380.scexe"],"md5sum":"3af3fa1712523b27f5c5bdf6fde893de","name":"firmware-system-u22-3.00_2021_04_01-1.1.i386.rpm","release":"2021-06-02T01:58:09","revision":"0","sha1sum":"253ef5451c319a99baf6f2da441e76952c320421","size":"5MB","target_guids":[],"type_of_change":"1","version":"3.00_04-01-2021"}],"id":{"product":"39ff5edbf84841ed9b674290e10d1356","version":"705316df12c440a488d62e4d6c97bd0f"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HPE ProLiant Agentless Management Service (<strong>AMS</strong>) and HPE SNMP Agents (<strong>SNMP Agents</strong>) are both running.&nbsp; HPE does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager 8.0.0 or later, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、iLOとの通信ができない場合に失敗します。  これは、HPE ProLiant Agentless Management Service (<strong>AMS</strong>)およびHPE SNMPエージェント(<strong>SNMP Agents</strong>)の両方が実行されているときに発生します。  HPEでは、AMSおよびSNMPエージェントを同時に実行させないことを推奨します。  「iLO device not found」エラーが発生した場合、AMSまたはSNMPエージェントを停止させて、再度フラッシュコンポーネントを実行します。<br />\n<br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上のSmart Update Manager 8.0.0以降を使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant DL20 Gen9 (U22) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Linux - HPE ProLiant DL20 Gen9 (U22)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-26T07:15:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode: 0x000000E2 (CPUID 506E3). This Intel microcode patch provide mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-8696 and CVE-2020-8698. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00381. These issues are not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-24512. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-464. The Intel microcode patches included in this release are version 0x000000EA (CPUID 506E3 and CPUID 906E9). These issues are not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel sighting CVE-2020-24512. This security vulnerability is documented in Intel Security Advisory INTEL-SA-00463. The Intel microcode patches included in this release are version 0x000000EA (CPUID 506E3) and 0x000000EA (CPUID 906E9). This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-8670 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"}],"sw_keys":[{"name":"U22","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWTFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG07scHPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57544644","Version":"HPD8"},{"DeviceName":"MB012000JWTFC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG07scHPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57544643","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB014000JWTFD and MB012000JWTFC"},{"lang":"ja","x_late":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB014000JWTFDおよびMB012000JWTFC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;-&nbsp;MB014000JWTFD and MB012000JWTFC Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>This firmware release provides additional protection against command timeouts.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp;None</p>\n"}],"files":[{"bytes":"4895220","datemodified":"2021-08-13T12:10:17","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-4ba9615f90-HPD8-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-4ba9615f90-HPD8-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-4ba9615f90-HPD8-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-4ba9615f90-HPD8-2.1/CP049121.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-4ba9615f90-HPD8-2.1/TAMG07scHPD8.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-4ba9615f90-HPD8-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-4ba9615f90-HPD8-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-4ba9615f90-HPD8-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-4ba9615f90-HPD8-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049121.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049121.scexe"],"md5sum":"b4d22e7bf5f05b112be9a145312bc836","name":"firmware-hdd-4ba9615f90-HPD8-2.1.x86_64.rpm","release":"2021-08-13T11:57:12","revision":"0","sha1sum":"bd7c1939454e5877a13ed0cfd9ba6d51886df12b","size":"4MB","target_guids":["4d2340a5-3042-3431-3030-304a57544644","4d2340a5-3042-3231-3030-304a57544643"],"type_of_change":"1","version":"HPD8"}],"id":{"product":"d2753039facd45788d8eb7892e214eed","version":"a728c8202ae448589c8ce0ced9652da9"},"installation":{"command":"CP040352.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB014000JWTFD and MB012000JWTFC Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB014000JWTFDおよびMB012000JWTFCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB014000JWTFD","target_guid":"4d2340a5-3042-3431-3030-304a57544644","type":"sas"},{"id":"MB012000JWTFC","target_guid":"4d2340a5-3042-3231-3030-304a57544643","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T12:31:34","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This firmware release provides additional protection against command timeouts.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This firmware release provides additional protection against command timeouts.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB014000JWTFD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB012000JWTFC","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"本產品包含適用於在 Red Hat Enterprise Linux 7 x86_64 下執行之 HPE Broadcom 乙太網路網路卡的驅動程式。"},{"lang":"en","x_late":"This product contains the drivers for the HPE Broadcom Ethernet NICs running under Red Hat Enterprise Linux 7 x86_64."},{"lang":"ko","x_late":"이 제품에는 Red Hat Enterprise Linux 5 x86_64에서 실행 중인 HPE Broadcom 이더넷 NIC용 드라이버가 포함되어 있습니다."},{"lang":"cn","x_late":"本产品包含适用于在 Red Hat Enterprise Linux 7 x86_64 下方运行的 HPE Broadcom 以太网网卡驱动程序。"},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7 x86_64で動作するHPE Broadcom Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"118472","datemodified":"2021-01-17T07:09:51","file_list":["./etc/depmod.d/tg3.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/tg3","./lib/modules/3.10.0-1127.el7.x86_64/extra/tg3/tg3.ko","./usr/share/smartupdate/kmod-tg3/component.xml"],"md5sum":"2e577aa848e57982fa2a1cc9fba319e1","name":"kmod-tg3-3.139b-1.rhel7u8.x86_64.rpm","release":"2021-01-17T07:02:05","revision":"0","sha1sum":"9ffb3913d1b2bde21868351d38269c6db68d30d5","size":"115KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6"],"type_of_change":"0","version":"3.139b-1"},{"bytes":"118475","datemodified":"2021-01-17T07:07:50","file_list":["./etc/depmod.d/tg3.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/tg3","./lib/modules/3.10.0-1160.el7.x86_64/extra/tg3/tg3.ko","./usr/share/smartupdate/kmod-tg3/component.xml"],"md5sum":"6b00b8e8dc8a92bfba2faae68af7d6ef","name":"kmod-tg3-3.139b-1.rhel7u9.x86_64.rpm","release":"2021-01-17T07:02:05","revision":"0","sha1sum":"233f44987be805e24559a094415ff1256682977f","size":"115KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6"],"type_of_change":"0","version":"3.139b-1"}],"id":{"product":"f4e486fae98c4ecea1e8d2f80f412bb9","version":"bf80ddf91812427facda6e8e5dfdcc45"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 Red Hat Enterprise Linux 7 x86_64 的 HPE Broadcom tg3 Ethernet 驅動程式"},{"lang":"en","x_late":"HPE Broadcom tg3 Ethernet Drivers for Red Hat Enterprise Linux 7 x86_64"},{"lang":"ko","x_late":"Red Hat Enterprise Linux 5 x86_64용 HPE Broadcom tg3 이더넷 드라이버"},{"lang":"cn","x_late":"适用于 Red Hat Enterprise Linux 7 x86_64 的 HPE Broadcom tg3 以太网驱动程序"},{"lang":"ja","x_late":"HPE Broadcom tg3 Ethernetドライバー for Red Hat Enterprise Linux 7 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"165F","subdev":"22E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c22e8","type":"pci","ven":"14E4"},{"dev":"1665","subdev":"22BD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1665103c22bd","type":"pci","ven":"14E4"},{"dev":"165F","subdev":"1786","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c1786","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"169D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c169d","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"3383","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c3383","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"22BE","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c22be","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 7 Update 8.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 7 update 9</p>\n","curr_fixes_x_late":"<p>The products fixes an a race condition issue where driver will still try to access the PHY(physical layer) although it was already brought down when the tg3 timer fires</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-tg3","sw_key_expectedpath":"software:rpm"},{"name":"kmod-tg3","sw_key_expectedpath":"software:rpm"},{"name":"kmod-tg3","sw_key_expectedpath":"software:rpm"},{"name":"kmod-tg3","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Intel i40e Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Intel i40e Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"3916371","datemodified":"2021-09-05T12:36:25","file_list":["./etc/depmod.d/hp-i40e.conf","./etc/dracut.conf.d/hp-i40e-oob.conf","./lib/modules/4.12.14-195-default","./lib/modules/4.12.14-195-default/updates","./lib/modules/4.12.14-195-default/updates/hp-i40e","./lib/modules/4.12.14-195-default/updates/hp-i40e/i40e.ko","./usr/share/smartupdate/hp-i40e-kmp-default/component.xml"],"md5sum":"b702295f9f520f378ef2818c92f401d1","name":"hp-i40e-kmp-default-2.14.13_k4.12.14_195-1.sles15sp1.x86_64.rpm","release":"2021-09-05T12:29:25","revision":"0","sha1sum":"a796925b54bfb1143f1d4ca89ccaa3f335ad8422","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccb9b3dbd"],"type_of_change":"0","version":"2.14.13-1"},{"bytes":"4608703","datemodified":"2021-09-05T12:39:22","file_list":["./etc/depmod.d/hp-i40e.conf","./etc/dracut.conf.d/hp-i40e-oob.conf","./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/hp-i40e","./lib/modules/5.3.18-22-default/updates/hp-i40e/i40e.ko","./usr/share/smartupdate/hp-i40e-kmp-default/component.xml"],"md5sum":"3c3b7002a0717291ade16977747a9d83","name":"hp-i40e-kmp-default-2.14.13_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-09-05T12:29:25","revision":"0","sha1sum":"4f90ffc238b6c65af857505b573d2c6258bc6c4b","size":"4MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccb9b3dbd"],"type_of_change":"0","version":"2.14.13-1"}],"id":{"product":"7204c0f5c514445a87ae5a6c742f6a37","version":"9e6080fc105147c8a36e1d04ffaff027"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"},{"lang":"ja","x_late":"<p>インストールのノートについてREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Intel i40e Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE Intel i40eドライバー for SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"},{"dev":"1572","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1572808600a1","type":"pci","ven":"8086"},{"dev":"1572","subdev":"0008","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-157280860008","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"1581","subdev":"00F8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1581159000f8","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-10-02T12:56:46","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue where the driver could result in kernel instability under heavy network conditions. Recommend to use this version 2.14.13(or later) as suggested by Intel TA-256(Technical Advisory).</p>\n"},{"curr_enhancements_x_late":"<p>This product supports the following new server:</p>\n\n<ul>\n\t<li>HPE ProLiant DL20 Gen10 Plus Server</li>\n\t<li>HPE ProLiant ML30 Gen10 Plus Server&nbsp;<br />\n\t&nbsp;</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"hp-i40e-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-i40e-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-i40e-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-i40e-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GVYYU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMPN6TG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304756595955","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB6000GVYYU"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online HDD/SSD&nbsp;Flash Component for VMware ESXi - MB6000GVYYU Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"17022592","datemodified":"2021-08-26T20:41:18","file_list":["/CP048372_BUILD_2.data","/CP048372.vmexe","/CP048372.vmexe64","/CP048372.vmfile","/CP048372_VMw.zip","/CP048372.xml","/payload.json","/CP048372_VMw.zip/index.xml","/CP048372_VMw.zip/vendor-index.xml","/CP048372_VMw.zip/metadata.zip","/CP048372_VMw.zip/vib20/CP048372/HPE_bootbank_CP048372_HPG2.2-7.0.0.15843807.vib","/CP048372_VMw.zip/metadata.zip/vendor-index.xml","/CP048372_VMw.zip/metadata.zip/vmware.xml","/CP048372_VMw.zip/metadata.zip/vibs/CP048372--3640455688668061355.xml","/CP048372_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048372_HPG2.2-7.0.0.15843807.xml"],"md5sum":"531614f4da7f153f09d72fff0fe4072f","name":"CP048372.zip","release":"2021-08-26T20:36:37","revision":"0","sha1sum":"73ba20af0d796aed76eed4fc9dad6e7bbdb3bb8c","size":"16MB","target_guids":["002340a5-4d00-3642-3030-304756595955"],"type_of_change":"1","version":"HPG2","vib_list":[{"name":"CP048372","version":"HPG2.2-7.0.0.15843807"}]}],"id":{"product":"543d676d322b4e8ab4ce97b5bffa1a41","version":"2d42e6fead3c4febb97a347f291efd92"},"installation":{"command":"CP040549.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB6000GVYYU Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB6000GVYYUドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB6000GVYYU","target_guid":"002340a5-4d00-3642-3030-304756595955","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-07T21:26:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000GVYYU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Intel ixgbe Ethernet NICs running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 8で動作するHPE Intel ixgbe Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"186366","datemodified":"2021-01-19T03:05:50","file_list":["./etc/depmod.d/hp-ixgbe.conf","./etc/dracut.conf.d/hp-ixgbe-oob.conf","./lib/modules/4.18.0-193.el8.x86_64","./lib/modules/4.18.0-193.el8.x86_64/extra","./lib/modules/4.18.0-193.el8.x86_64/extra/hp-ixgbe","./lib/modules/4.18.0-193.el8.x86_64/extra/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/kmod-hp-ixgbe/component.xml"],"md5sum":"b87a94d6c14904ae2709dea9694a5a53","name":"kmod-hp-ixgbe-5.9.4-1.rhel8u2.x86_64.rpm","release":"2021-01-19T02:59:05","revision":"0","sha1sum":"b6cfe7591e0ada35e772941cd24bceb9a8860d80","size":"181KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccba99d79"],"type_of_change":"0","version":"5.9.4-1"},{"bytes":"186467","datemodified":"2021-01-19T03:09:07","file_list":["./etc/depmod.d/hp-ixgbe.conf","./etc/dracut.conf.d/hp-ixgbe-oob.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/hp-ixgbe","./lib/modules/4.18.0-240.el8.x86_64/extra/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/kmod-hp-ixgbe/component.xml"],"md5sum":"252c9b6cd85e10ab8ab286a442a81bad","name":"kmod-hp-ixgbe-5.9.4-1.rhel8u3.x86_64.rpm","release":"2021-01-19T02:59:05","revision":"0","sha1sum":"51e8816746d513a8b0df0f5abef64df35185be2c","size":"182KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccba99d79"],"type_of_change":"0","version":"5.9.4-1"}],"id":{"product":"760adb908c054b5b910c54e6c4a5f9e4","version":"0a720e62376e46e3be17948808b902ba"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>Download README for any additional installation instructions.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Intel ixgbe Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE Intel ixgbeドライバー for Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"},{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c192d","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c211a","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"},{"dev":"152E","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d3","type":"pci","ven":"8086"},{"dev":"1530","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product update Linux kernel documentation and Configure IRQ affinity tools</p>\n","latest_fixes_x_late":"<p>This product corrects an issue which errata kernel loads inbox driver instead of this component after booting into OS</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>This product now supports Red Hat Enterprise Linux 8 update 2 and Red Hat Enterprise Linux 8 update 3</li>\n\t<li>This product enhances reliability via adding support for new mailbox communication between PF(Physical Function) and VF(Virtual Function) and remove its potential flaws that may lead to the undefined or faulty behavior</li>\n\t<li>This product enhances compatibility where new mailbox api implementation is alo compatible with old drivers</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-hp-ixgbe","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbe","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbe","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbe","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900083","languages":[{"lang":"tw","x_late":"韌體 ─ 電源管理"},{"lang":"en","x_late":"Firmware - Power Management"},{"lang":"ko","x_late":"펌웨어 - 전원 관리"},{"lang":"ja","x_late":"ファームウェア - パワー マネジメント"},{"lang":"cn","x_late":"固件 - 电源管理"}]}],"description":[{"lang":"tw","x_late":"此元件可更新電源管理控制器韌體。 "},{"lang":"en","x_late":"This component updates the Power Management Controller firmware. "},{"lang":"ko","x_late":"이 구성 요소는 전원 관리 컨트롤러 펌웨어를 업데이트합니다. "},{"lang":"cn","x_late":"该组件更新电源管理控制器固件。 "},{"lang":"ja","x_late":"このコンポーネントは、Power Management Controllerファームウェアをアップデートします。 "}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"625984","datemodified":"2018-10-08T15:37:53","file_list":["amd64/","amd64/CpqCi.dll","amd64/CpqCi32.dll","amd64/cpqcidrv.cat","amd64/CpqCiDrv.inf","amd64/CpqCiDrv.sys","amd64/cpqsmif.dll","amd64/cpqsmif32.dll","amd64/drvinst.exe","cp037764.xml","cpqsetup.exe","cpqsysio64.sys","firmware.ini","PowerPicInstaller64.dll","SNARFR41.hex"],"md5sum":"6d9b73c0788acf505ceab3cb16d05f38","name":"cp037764.exe","release":"2018-10-08T20:37:06","revision":"0","sha1sum":"59ce1766d4c7b21fc4292eb279299ca48daa1a08","size":"611KB","target_guids":[],"type_of_change":"1","version":"4.1"}],"id":{"product":"5e40c73cb84f441f80acf9f709720859","version":"dd821dd7504540a78e4228ce17f5730d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">To update firmware from Windows operating system on target server:</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired components&nbsp;to be updated in the directory, \\packages on the USB key. To use with SUM 7.6.0 or earlier, place the components in \\hp\\swpackages on the USB Key.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.&nbsp;<br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">This component can only be executed on Windows x64.</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"Online ROM Flash for Windows x64 - Power Management Controller for HPE ProLiant DL580 Gen9/Gen8 Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"6","minor":"0","name":"Microsoft Windows Server 2008 x64","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"edition":"hpc","major":"6","minor":"1","name":"Microsoft Windows HPC Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"5","minor":"2","name":"Microsoft Windows HPC Server 2008","platform":"NT","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-11-03T15:03:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>Ver.&nbsp;4.1 (E) contains an update to resolve information disclosure vulnerability issue ref: CVE-2017-8992.&nbsp; It is functionally equivalent to ver. 4.1.&nbsp; It is not necessary to upgrade with Revision&nbsp;(E) if a previous component revision was used to upgrade the firmware to ver.4.1.</p>\n\n<p><strong><strong>Firmware Dependencies:</strong></strong></p>\n\n<p>None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>This is the initial version of the firmware.</p>\n\n<p><strong><strong>Known Issues:</strong></strong></p>\n\n<p>The smart component prompts for reboot unnecessarily when the installation procedure is completed. Reboot is not required after installation for updates to take effect and hardware stability to be maintained.<br />\n&nbsp;</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>Ver.&nbsp;4.1 (F) adds support to perform the Online ROM Flash with Microsoft Windows Server 2016 by using Smart Update Manager.&nbsp; It is functionally equivalent to ver. 4.1.&nbsp; It is not necessary to upgrade with Revision&nbsp;(F) if a previous component revision was used to upgrade the firmware to ver.4.1.</p>\n\n<p><strong><strong>Firmware Dependencies:</strong></strong></p>\n\n<p>None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>This is the initial version of the firmware.</p>\n\n<p><strong><strong>Known Issues:</strong></strong></p>\n\n<p>The smart component prompts for reboot unnecessarily when the installation procedure is completed. Reboot is not required after installation for updates to take effect and hardware stability to be maintained.<br />\n&nbsp;</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"}],"sw_keys":[{"name":"PowerPIC-DL580","sw_key_expectedpath":"firmware:QLOGIC"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This component contains drivers for the HPE Broadcom NX1 1Gb Ethernet Adapters for Microsoft Windows Server 2016 and Windows Server 2019."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"981008","datemodified":"2021-02-09T07:35:58","file_list":["b57nd60a.cat","b57nd60a.inf","b57nd60a.sys","cp045019.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"md5sum":"3a7f969f4518f9100a46b60b84c42f30","name":"cp045019.exe","release":"2021-02-09T07:22:05","revision":"0","sha1sum":"062c0484166e1e5297ed03643dbef691d6f1c0ea","size":"958KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3f40450a"],"type_of_change":"0","version":"214.0.0.6"}],"id":{"product":"b9a8e50fea15459f9f236f2538fb4a07","version":"6796559031774402b1116055f89cc4a0"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"tw","x_late":"將智慧型元件下載至硬碟上的目錄，並變更至該目錄。<p>從該磁碟和目錄，執行下載的檔案。<p>按一下「Install」(安裝) 按鈕，繼續執行安裝程序。"},{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the \"Install\" button to proceed with the installation."},{"lang":"ko","x_late":"스마트 구성 요소를 하드 드라이브의 디렉터리로 다운로드하고 그 디렉터리로 이동합니다.<p>드라이브와 디렉터리에서 다운로드한 파일을 실행합니다.<p>\"설치\" 버튼을 클릭하여 설치 작업을 진행합니다."},{"lang":"cn","x_late":"将 Smart Component 下载到硬盘目录中，然后转至该目录。<p>在该硬盘目录中，执行下载的文件。<p>点击“安装”按钮进行安装。"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスク ドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NX1 1Gb Driver for Windows Server x64 Editions"},{"lang":"ja","x_late":"HPE Broadcom NX1 1Gbドライバーfor Windows Server x64 Edition"}],"prerequisites":{"required_diskspace":{"size_kb":"600"},"supported_devices":[{"dev":"165F","subdev":"22E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c22e8","type":"pci","ven":"14E4"},{"dev":"1665","subdev":"22BD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1665103c22bd","type":"pci","ven":"14E4"},{"dev":"165F","subdev":"1786","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c1786","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"169D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c169d","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"3383","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c3383","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"22BE","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c22be","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This product correct an issue which system crashed while enable/disable cycle when running along with certain video driver.</li>\n\t<li>This product correct an issue which the Gets statistics from a network adapter command (Get-NetAdapterStatistics) does not work with WS2019.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product correct an issue which fixes Windows driver causes NMI/RSOD during OS shutdown.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"b57nd60a.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"本產品包含 SUSE Linux Enterprise Server 12 x86_64 下執行的 HPE Intel Gigabit 乙太網路 NIC 驅動程式。"},{"lang":"en","x_late":"This product contains the drivers for HPE Intel Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 12 x86_64."},{"lang":"ko","x_late":"이 제품에는 SUSE Linux Enterprise Server 12 x86_64에서 실행되는 HPE Intel 기가비트 이더넷 NIC용 드라이버가 포함되어 있습니다."},{"lang":"cn","x_late":"本产品包含适用于在 SUSE Linux Enterprise Server 12 x86_64 下方运行的 HPE Intel 千兆以太网网卡驱动程序。"},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12 x86_64で動作するHPE Intel Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"2950923","datemodified":"2021-08-24T15:06:20","file_list":["./etc/depmod.d/hp-igb.conf","./etc/dracut.conf.d/hp-igb-oob.conf","./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/hp-igb","./lib/modules/4.12.14-120-default/updates/hp-igb/igb.ko","./usr/share/smartupdate/hp-igb-kmp-default/component.xml"],"md5sum":"649048623d7ce6466f901c79b535542e","name":"hp-igb-kmp-default-6.7.2_k4.12.14_120-2.sles12sp5.x86_64.rpm","release":"2021-08-24T14:59:07","revision":"0","sha1sum":"01af3e6f776a8415e4312674b9775b32f74fa8b4","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec7f45f646"],"type_of_change":"0","version":"6.7.2-2"}],"id":{"product":"5049ff108a414cae906f3f80d242a819","version":"b768e53ab0d943a6adf7db4b1439ae43"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 SUSE Linux Enterprise Server 12 x86_64 的 HPE Intel igb 驅動程式"},{"lang":"en","x_late":"HPE Intel igb Drivers for SUSE Linux Enterprise Server 12 x86_64"},{"lang":"ko","x_late":"SUSE Linux Enterprise Server 12 x86_64용 HPE Intel igb 드라이버"},{"lang":"cn","x_late":"适用于 SUSE Linux Enterprise Server 12 x86_64 的 HPE Intel igb 驱动程序 "},{"lang":"ja","x_late":"HPE Intel igbドライバー for SUSE Linux Enterprise Server 12 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1523","subdev":"1989","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1523103c1989","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00FF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1521159000ff","type":"pci","ven":"8086"},{"dev":"1521","subdev":"337F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c337f","type":"pci","ven":"8086"},{"dev":"1521","subdev":"339E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c339e","type":"pci","ven":"8086"},{"dev":"1521","subdev":"17D1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c17d1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"3380","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-1521103c3380","type":"pci","ven":"8086"},{"dev":"1521","subdev":"8157","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c8157","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00A3","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a3","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now support HPE Intel Online Firmware Upgrade Utility for Linux x86_64, version (or later) to update firmware</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports Linux Firmware upgrade utility v.1.22.5</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"hp-igb-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter and mezzanine host bus adapters. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"5763860","datemodified":"2021-08-27T03:31:40","file_list":["./etc/depmod.d/qla2xxx.conf","./etc/udev/rules.d/99-nvme-fc.rules","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/qlgc-qla2xxx","./lib/modules/3.10.0-1127.el7.x86_64/extra/qlgc-qla2xxx/qla2xxx.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/qlgc-qla2xxx/tcm_qla2xxx.ko","./usr/lib/dracut/dracut.conf.d/70-qla2xxx-nvmefc-autoconnect.conf","./usr/lib/systemd/system/qla2xxx-nvmefc-boot-connection.service","./usr/lib/systemd/system/qla2xxx-nvmefc-connect@.service","./usr/lib/udev/rules.d/70-qla2xxx-nvmefc-autoconnect.rules","./usr/sbin/qla2xxx/qla2xxx_nvme_boot_connections.sh","./usr/share/smartupdate/kmod-qlgc-qla2xxx/component.xml"],"md5sum":"14f453aedbaad1c7513e603e4728f7b8","name":"kmod-qlgc-qla2xxx-10.02.01.00.a14_k1-1.rhel7u8.x86_64.rpm","release":"2021-08-27T03:21:53","revision":"0","sha1sum":"f5e9b9b8340e514dc90c95812dccb432c8dcd722","size":"5MB","target_guids":[],"type_of_change":"1","version":"10.02.01.00.a14-k1"}],"id":{"product":"3ba7dff38db742eb95d40afd3fbd4785","version":"e8f4d15d84f0434e9a56941ce4f8737b"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-qla2xxx-4.6.28-20.rhel6u1.x86_64.rpm<br />\n<br />\n4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;&nbsp;</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Red Hat Enterprise Linux 7 Update 8 Server Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters and Mezzanine Host Bus Adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015D","subven":"1077","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015C","subven":"1077","target_guid":"","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-18T06:47:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to driver version 10.02.01.00.a14-k1</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"kmod-qlgc-qla2xxx","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The HPE SNMP Agents (hp-snmp-agents) is a collection  of SNMP  protocol based agents  and tools which enables monitoring of fans, power supplies, temperature sensors and other management events via SNMP. It also provides the following: Foundation and Server agents, Storage Subsystem agents, Network Subsystem agents, the SNMP Dynamically Loaded Module, and the web support applications."},{"lang":"ja","x_late":"HPE SNMPエージェント（hp-snmp-agents）は、ファン、電源、温度センサー、およびその他SNMP経由の管理イベントの監視を可能にするSNMPプロトコルベースのエージェントとツールを集めたものです。同様に、以下を提供します。FoundationおよびServerエージェント、Storage Subsystemエージェント、Network Subsystemエージェント、SNMP動的ロードモジュール、およびWebサポートアプリケーション。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[{"lang":"en","x_late":null}],"files":[{"bytes":"1381747","datemodified":"2021-08-25T03:48:36","file_list":["./etc/hp-snmp-agents.conf","./etc/logrotate.d/hp-snmp-agents","./opt/hp/hp-snmp-agents","./opt/hp/hp-snmp-agents/addons","./opt/hp/hp-snmp-agents/cma.conf","./opt/hp/hp-snmp-agents/hp-snmp-agents.license","./opt/hp/hp-snmp-agents/hp-snmp-agents.manifest","./opt/hp/hp-snmp-agents/hp-snmp-agents.rebuild.spec","./opt/hp/hp-snmp-agents/hprpm.xpm","./opt/hp/hp-snmp-agents/mibs","./opt/hp/hp-snmp-agents/mibs/cmafdtnobjects.conf","./opt/hp/hp-snmp-agents/mibs/cmanicobjects.conf","./opt/hp/hp-snmp-agents/mibs/cmaobjects.conf","./opt/hp/hp-snmp-agents/mibs/cmaobjects.mibdef","./opt/hp/hp-snmp-agents/mibs/cmaobjects.mibver","./opt/hp/hp-snmp-agents/mibs/cmaobjects.regmib","./opt/hp/hp-snmp-agents/mibs/cmastorobjects.conf","./opt/hp/hp-snmp-agents/mibs/cmasvrobjects.conf","./opt/hp/hp-snmp-agents/nic","./opt/hp/hp-snmp-agents/nic/bin","./opt/hp/hp-snmp-agents/nic/bin/cmanicd","./opt/hp/hp-snmp-agents/nic/bin/hpetfe","./opt/hp/hp-snmp-agents/nic/etc","./opt/hp/hp-snmp-agents/nic/etc/HPcmanic.pp","./opt/hp/hp-snmp-agents/nic/etc/cmanic","./opt/hp/hp-snmp-agents/nic/etc/cmanicd","./opt/hp/hp-snmp-agents/rebuild","./opt/hp/hp-snmp-agents/server","./opt/hp/hp-snmp-agents/server/bin","./opt/hp/hp-snmp-agents/server/bin/cmahealthd","./opt/hp/hp-snmp-agents/server/bin/cmahostd","./opt/hp/hp-snmp-agents/server/bin/cmapeerd","./opt/hp/hp-snmp-agents/server/bin/cmaperfd","./opt/hp/hp-snmp-agents/server/bin/cmasm2d","./opt/hp/hp-snmp-agents/server/bin/cmastdeqd","./opt/hp/hp-snmp-agents/server/bin/cmathreshd","./opt/hp/hp-snmp-agents/server/bin/distro-id.sh","./opt/hp/hp-snmp-agents/server/etc","./opt/hp/hp-snmp-agents/server/etc/cmad","./opt/hp/hp-snmp-agents/server/etc/cmahealthd","./opt/hp/hp-snmp-agents/server/etc/cmahostd","./opt/hp/hp-snmp-agents/server/etc/cmapeerd","./opt/hp/hp-snmp-agents/server/etc/cmaperfd","./opt/hp/hp-snmp-agents/server/etc/cmarackd","./opt/hp/hp-snmp-agents/server/etc/cmasm2d","./opt/hp/hp-snmp-agents/server/etc/cmastdeqd","./opt/hp/hp-snmp-agents/server/etc/cmathreshd","./opt/hp/hp-snmp-agents/server/etc/cpqbssa.txt","./opt/hp/hp-snmp-agents/server/etc/cpqriisd","./opt/hp/hp-snmp-agents/share","./opt/hp/hp-snmp-agents/share/doc","./opt/hp/hp-snmp-agents/share/doc/HP_SNMP_Trap_Guide.txt","./opt/hp/hp-snmp-agents/storage","./opt/hp/hp-snmp-agents/storage/bin","./opt/hp/hp-snmp-agents/storage/bin/cmaeventd","./opt/hp/hp-snmp-agents/storage/bin/cmafcad","./opt/hp/hp-snmp-agents/storage/bin/cmaidad","./opt/hp/hp-snmp-agents/storage/bin/cmaided","./opt/hp/hp-snmp-agents/storage/bin/cmasasd","./opt/hp/hp-snmp-agents/storage/bin/cmascsid","./opt/hp/hp-snmp-agents/storage/bin/libcpqimgr-x86_64.so","./opt/hp/hp-snmp-agents/storage/etc","./opt/hp/hp-snmp-agents/storage/etc/cmaeventd","./opt/hp/hp-snmp-agents/storage/etc/cmafcad","./opt/hp/hp-snmp-agents/storage/etc/cmaidad","./opt/hp/hp-snmp-agents/storage/etc/cmaided","./opt/hp/hp-snmp-agents/storage/etc/cmasasd","./opt/hp/hp-snmp-agents/storage/etc/cmascsid","./opt/hp/hp-snmp-agents/storage/etc/cmastorobjects.conf","./opt/hp/hp-snmp-agents/utils","./opt/hp/hp-snmp-agents/utils/usb-device.sh","./opt/hp/hp-snmp-agents/webagent","./opt/hp/hp-snmp-agents/webagent/csginkgo","./sbin/hpsnmpconfig","./usr/lib/.build-id","./usr/lib/.build-id/13","./usr/lib/.build-id/13/ff24e4788038fa5e43c6ad0e4f2c64dbbdc525","./usr/lib/.build-id/1a","./usr/lib/.build-id/1a/c442b76762de1d3d770d71b0439143343c4c62","./usr/lib/.build-id/21","./usr/lib/.build-id/21/35d81d19bc07e91ff7a6d43c6bb66e691570c8","./usr/lib/.build-id/24","./usr/lib/.build-id/24/5fc8679b46128c9cace0d6c71aa45353a71dae","./usr/lib/.build-id/2d","./usr/lib/.build-id/2d/3fe12664697a5b79c2abd0b280820e983e64d0","./usr/lib/.build-id/49","./usr/lib/.build-id/49/691a596505331dd70884e8aa9c705633a12d41","./usr/lib/.build-id/5a","./usr/lib/.build-id/5a/bee339a09322e3ee955c8f54cee1dca9d743cc","./usr/lib/.build-id/5c","./usr/lib/.build-id/5c/549646e4b066333170166513ac2619c05b2923","./usr/lib/.build-id/61","./usr/lib/.build-id/61/600affe0c149d8c230303741998de7902344dc","./usr/lib/.build-id/81","./usr/lib/.build-id/81/ca2cb2257a87d3ec7adb4c8104f5b1afa84e7f","./usr/lib/.build-id/99","./usr/lib/.build-id/99/1a835d63e27ccf73b2ae0cc40d5c75287655be","./usr/lib/.build-id/aa","./usr/lib/.build-id/aa/9f4373fe3d348d249e08cbf282a743d412ca91","./usr/lib/.build-id/c1","./usr/lib/.build-id/c1/d7d00f5e0e6ff22644f257b61a7a70e82eb6ad","./usr/lib/.build-id/c5","./usr/lib/.build-id/c5/f48d1930b3b0750862453afb42197c8a52cc59","./usr/lib/.build-id/cd","./usr/lib/.build-id/cd/27cc7bda4d3dc29f149d8b1e38445fd61943c8","./usr/lib/.build-id/d1","./usr/lib/.build-id/d1/12ca3fe02d9def51464797689c9560aa22e3d9","./usr/lib/.build-id/e9","./usr/lib/.build-id/e9/78885a67ab6abc4f1980c22181ddd8db2ae5fb","./usr/lib/.build-id/f0","./usr/lib/.build-id/f0/f3910b7c937d6fc958859528694f5a27d49654","./usr/lib/.build-id/fb","./usr/lib/.build-id/fb/e168656888a4c6de660af6580c1642aa1b8792","./usr/lib/systemd/scripts/hp-snmp-agents.sh","./usr/lib/systemd/system/hp-snmp-agents.service","./usr/lib64/libcmaX64.so","./usr/lib64/libcmaX64.so.1","./usr/lib64/libcmaX64.so.1.0","./usr/lib64/libcmacommon64.so","./usr/lib64/libcmacommon64.so.1","./usr/lib64/libcmacommon64.so.1.0","./usr/lib64/libcmaconf64.so","./usr/lib64/libcmaconf64.so.1","./usr/lib64/libcmaconf64.so.1.0","./usr/lib64/libcmapeer64.so","./usr/lib64/libcmapeer64.so.1","./usr/lib64/libcmapeer64.so.1.0","./usr/share/man/man4/hp-snmp-agents.4.gz","./usr/share/man/man8/cmanicd.8.gz","./usr/share/smartupdate/hp-snmp-agents/component.xml","./var/log/hp-snmp-agents","./var/spool/compaq"],"md5sum":"5e557d1a055b1123c3ef60d6f1c6e175","name":"hp-snmp-agents-10.94-689.8.rhel8.x86_64.rpm","release":"2021-08-25T03:40:04","revision":"0","sha1sum":"876b62cfae7b7ee2d565aac0c0eddcaf43651861","size":"1MB","target_guids":[],"type_of_change":"0","version":"10.9.4"}],"id":{"product":"ea9fa4d5a6f7491799a049be7661a52e","version":"a58104eba5914459bf63e41e6dd14736"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<P>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</P>\n<P>To install the package, type: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<B><I>rpm -ivh hp-snmp-agents-&lt;version&gt;.rpm</I></B></P>\n<P>To check whether the package is loaded properly type: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<B><I>/etc/init.d/hp-snmp-agents status</I></B></P>\n<P>Additional help is available by typing: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<B><I>man hp-snmp-agents</I></B></P>"},{"lang":"ja","x_late":"<P>システム管理者（root）としてログインし、RPMをご使用のハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</P>\n<P>パッケージをインストールするには、次のようにタイプします。</P>\n<P>         <B><I>rpm -ivh hp-snmp-agents-<version>.rpm</I></B></P>\n<P>パッケージが正しくロードされているか、以下をタイプして確認します。</P>\n<P>         <B><I>/etc/init.d/hp-snmp-agents status</I></B></P>\n<P>以下のコマンドを実行してヘルプを参照してください。</P>\n<P>         <B><I>man hp-snmp-agents</I></B></P>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE SNMP Agents for Red Hat Enterprise Linux 8 Server"},{"lang":"ja","x_late":"HPE SNMPエージェントfor Red Hat Enterprise Linux 8 Server"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"3309","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3307","subdev":"3309","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-28T13:04:13","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>Addressed issue where the HPE Synergy 3820C 10/20Gb Converged Network Adapter was showing not supported</li>\n\t<li>Corrected invalid utf8mb4 char in database</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>TBD</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"}],"sw_keys":[{"name":"hp-snmp-agents","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXe0HPD7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5748504b","Version":"HPD7"},{"DeviceName":"EH000600JWHPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXe0HPD7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57485048","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EH000900JWHPK and EH000600JWHPH"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EH000900JWHPK および EH000600JWHPH ドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - EH000900JWHPK and EH000600JWHPH Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added supported for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3000720","datemodified":"2021-07-26T17:31:47","file_list":["cp049134.xml","cpqsetup.exe","payload.json","setup.dll","TA14SXe0HPD7.REL"],"md5sum":"75d6509bb11e2ef75d097f33f0470d45","name":"cp049134.exe","release":"2021-07-26T17:24:06","revision":"0","sha1sum":"f09b256d0b1637db8f36d434b746b7a2a430091e","size":"2MB","target_guids":["452340a5-3048-3030-3930-304a5748504b","452340a5-3048-3030-3630-304a57485048"],"type_of_change":"1","version":"HPD7"}],"id":{"product":"7e6f42aebfdb4390968da43b36518880","version":"b837b9dbcf8946ff960a9920c71e5b88"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration-line: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EH000900JWHPK and EH000600JWHPH  Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EH000900JWHPKおよびEH000600JWHPHドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EH000600JWHPH","target_guid":"452340a5-3048-3030-3630-304a57485048","type":"sas"},{"id":"EH000900JWHPK","target_guid":"452340a5-3048-3030-3930-304a5748504b","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T17:19:04","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This firmware provides a change to the Vendor ID in the VPD page that refers to HP instead of HPE.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added supported for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH000600JWHPH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000900JWHPK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Blade Intel ixgbe Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Blade Intel ixgbe Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"4202166","datemodified":"2021-03-08T20:09:31","file_list":["./lib/modules/4.12.14-195-default","./lib/modules/4.12.14-195-default/updates","./lib/modules/4.12.14-195-default/updates/hp-ixgbe","./lib/modules/4.12.14-195-default/updates/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/hp-ixgbe_bl-kmp-default/component.xml"],"md5sum":"5bb6365255c19eea87674f7548864bff","name":"hp-ixgbe_bl-kmp-default-5.9.4_k4.12.14_195-1.sles15sp1.x86_64.rpm","release":"2021-03-08T20:04:08","revision":"0","sha1sum":"7884b01cc5e342e777142e26358d84f6d428dd9d","size":"4MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf57995ac"],"type_of_change":"0","version":"5.9.4-1"},{"bytes":"4991622","datemodified":"2021-03-08T20:10:55","file_list":["./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/hp-ixgbe","./lib/modules/5.3.18-22-default/updates/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/hp-ixgbe_bl-kmp-default/component.xml"],"md5sum":"d2d5089730ce54447d91283791a01f40","name":"hp-ixgbe_bl-kmp-default-5.9.4_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-03-08T20:04:08","revision":"0","sha1sum":"5580ad40a933fa32894fcf1ec7d2922156b2b3ff","size":"4MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf57995ac"],"type_of_change":"0","version":"5.9.4-1"}],"id":{"product":"89efa5dd7c1545c0ad8e16f58fcdfeb6","version":"9c22c5cc997d4b678633ba92b3bb24f1"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Intel ixgbe Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE Blade Intel ixgbeドライバーfor SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c18d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-03-19T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>These drivers have been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 15 SP2.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"hp-ixgbe_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbe_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbe_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbe_bl-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"ET000750KWJTF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICSHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3054-3030-3735-304b574a5446","Version":"4ICSHPK4"},{"DeviceName":"EO000375KWJUC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICSHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3337-354b574a5543","Version":"4ICSHPK4"},{"DeviceName":"EO000750KWTXC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICSHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3735-304b57545843","Version":"4ICSHPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: ET000750KWJTF, EO000750KWTXC and EO000375KWJUC"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。ET000750KWJTF、EO000750KWTXC、およびEO000375KWJUC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for VMware ESXi - ET000750KWJTF, EO000750KWTXC and EO000375KWJUC Drives</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp;&nbsp; 4ICSHPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; 4ICSHPK2</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:&nbsp;</strong><br />\n&nbsp; &nbsp;&nbsp; 4ICSHPK2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p>\n\n<p style=\"text-align:left\">&nbsp; &nbsp; &nbsp;None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"15833501","datemodified":"2021-08-27T09:24:59","file_list":["/CP048513_BUILD_2.data","/CP048513.vmexe","/CP048513.vmexe64","/CP048513.vmfile","/CP048513_VMw.zip","/CP048513.xml","/payload.json","/CP048513_VMw.zip/index.xml","/CP048513_VMw.zip/vendor-index.xml","/CP048513_VMw.zip/metadata.zip","/CP048513_VMw.zip/vib20/CP048513/HPE_bootbank_CP048513_4ICSHPK4.2-7.0.0.15843807.vib","/CP048513_VMw.zip/metadata.zip/vendor-index.xml","/CP048513_VMw.zip/metadata.zip/vmware.xml","/CP048513_VMw.zip/metadata.zip/vibs/CP048513-6652579536536410431.xml","/CP048513_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048513_4ICSHPK4.2-7.0.0.15843807.xml"],"md5sum":"cce79b019f1a9f6793db36fa5ee578a3","name":"CP048513.zip","release":"2021-08-27T09:19:48","revision":"0","sha1sum":"3a26d093f2dca9c849f95a00605d12b2bd4003de","size":"15MB","target_guids":["452340a5-3054-3030-3735-304b574a5446","452340a5-304f-3030-3337-354b574a5543","452340a5-304f-3030-3735-304b57545843"],"type_of_change":"1","version":"4ICSHPK4","vib_list":[{"name":"CP048513","version":"4ICSHPK4.2-7.0.0.15843807"}]}],"id":{"product":"f09974e786ab4852855854b483956c19","version":"40e72cc1ea4748ba926cb4c822f9c153"},"installation":{"command":"CP042960.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>HP Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例: ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi - ET000750KWJTF, EO000750KWTXC and EO000375KWJUC Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - ET000750KWJTF、EO000750KWTXC、およびEO000375KWJUCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"ET000750KWJTF","target_guid":"452340a5-3054-3030-3735-304b574a5446","type":"nvme"},{"id":"EO000375KWJUC","target_guid":"452340a5-304f-3030-3337-354b574a5543","type":"nvme"},{"id":"EO000750KWTXC","target_guid":"452340a5-304f-3030-3735-304b57545843","type":"nvme"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T09:25:33","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Fixed HPK3 drive reports incorrect Device ID issue.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EO000375KWJUC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"EO000750KWTXC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"ET000750KWJTF","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWKGR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574b4752","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB006000GWKGR"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB006000GWKGR Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4292520","datemodified":"2021-07-23T18:24:55","file_list":["cp048674.xml","cpqsetup.exe","HVLAeAaseFG1.rel","payload.json","setup.dll"],"md5sum":"792d618f1260850671aa6daab4dd7d6b","name":"cp048674.exe","release":"2021-07-23T18:17:10","revision":"0","sha1sum":"1573c19909f4b2946646bdb5d6efd820ed82dc85","size":"4MB","target_guids":["4d2340a5-3042-3630-3030-3047574b4752"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"4fd1e8e4a27347cd8d83d1e63d9eb38e","version":"d36fe0fd23234446ac6b0deb81dcd353"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB006000GWKGR Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB006000GWKGRドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB006000GWKGR","target_guid":"4d2340a5-3042-3630-3030-3047574b4752","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-17T08:42:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000GWKGR","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The Smart Storage Administrator CLI (SSACLI) is a commandline-based disk configuration program that helps you configure, manage, diagnose, and monitor Smart Array and SmartRAID Controllers and now other storage devices as well, such as host bus adapters (HBAs), Storage controllers, and future devices such as SCSI Express drives, and SAS switch devices. \n\nSSASCRIPTING - Scripting can be performed in offline or online environments.  The SSA Scripting application has 2 scripting modes – Capture and Input."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"16605930","datemodified":"2021-08-11T13:20:19","file_list":["./opt/smartstorageadmin/ssacli","./opt/smartstorageadmin/ssacli/bin","./opt/smartstorageadmin/ssacli/bin/mklocks.sh","./opt/smartstorageadmin/ssacli/bin/rmstr","./opt/smartstorageadmin/ssacli/bin/ssacli","./opt/smartstorageadmin/ssacli/bin/ssacli-5.20-8.0.x86_64.txt","./opt/smartstorageadmin/ssacli/bin/ssacli.license","./opt/smartstorageadmin/ssacli/bin/ssascripting","./usr/man/man8/ssacli.8.gz","./usr/sbin/ssacli","./usr/sbin/ssascripting","./usr/share/smartupdate/ssacli/component.xml"],"md5sum":"12631160ad48ffd77fd7579718cece17","name":"ssacli-5.20-8.0.x86_64.rpm","release":"2021-08-11T13:11:12","revision":"0","sha1sum":"6b819dcc64bc4c37bd50e9d0a3e983eb34afc2f1","size":"15MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecff0816bd"],"type_of_change":"1","version":"5.20.8.0"}],"id":{"product":"51c52bf006bd4c60b09797563ff886bf","version":"e8b00a323a3e415db13dafa24a22d086"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<ul>\n\t<li>SSACLI is distributed using Red Hat Package Manager (RPM) packages.</li>\n\t<li>If there is an older version of SSACLI installed on the system, please use &quot;rpm -e ssacli&quot; to remove it first.</li>\n\t<li>Use &quot;rpm -i &lt;file name&gt;&quot; to install the application.</li>\n\t<li>Please type &quot;man rpm&quot; for other details regarding RPM.</li>\n\t<li>The software resides in /opt/smartstorageadmin/ssacli and the executable name is ssacli which is located in /usr/sbin.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Linux (64 位元) 的 Smart Storage Administrator (智慧型儲存管理員 (SSA)) CLI"},{"lang":"en","x_late":"Smart Storage Administrator (SSA) CLI for Linux 64-bit"},{"lang":"ko","x_late":"Linux 64비트용 스마트 스토리지 관리자(SSA) CLI"},{"lang":"cn","x_late":"64位Linux版Smart Storage Administrator (SSA) CLI"},{"lang":"ja","x_late":"Smart Storage Administrator (SSA) CLI for Linux 64ビット"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-09T05:29:08","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added&nbsp;support&nbsp;to the HPE&nbsp;SR932i-p and SR416-a&nbsp;Gen10+&nbsp;Controllers.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>.</p>\n\n<p>&nbsp;</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U38","value":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"key":"U38","value":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"key":"","value":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U14","value":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4520 Gen9 Chassis</p>\n"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U27","value":"HPE ProLiant XL2x260w Gen9 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>\n"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"","value":"HPE ProLiant ML150 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"","value":"HPE ProLiant XL770f Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"Carbondale14","value":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"ssacli","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000JWDFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEAHssseFD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57444644","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB012000JWDFD"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB012000JWDFD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB012000JWDFD Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"18512086","datemodified":"2021-08-27T08:51:23","file_list":["/CP048404_BUILD_2.data","/CP048404.vmexe","/CP048404.vmexe64","/CP048404.vmfile","/CP048404_VMw.zip","/CP048404.xml","/payload.json","/CP048404_VMw.zip/index.xml","/CP048404_VMw.zip/vendor-index.xml","/CP048404_VMw.zip/metadata.zip","/CP048404_VMw.zip/vib20/CP048404/HPE_bootbank_CP048404_HPD3.2-7.0.0.15843807.vib","/CP048404_VMw.zip/metadata.zip/vendor-index.xml","/CP048404_VMw.zip/metadata.zip/vmware.xml","/CP048404_VMw.zip/metadata.zip/vibs/CP048404-2380168779059635809.xml","/CP048404_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048404_HPD3.2-7.0.0.15843807.xml"],"md5sum":"66961f8c0598cab8637b931aa303a766","name":"CP048404.zip","release":"2021-08-27T08:45:54","revision":"0","sha1sum":"bcd3b46a58d2877fd3ff9ec5e107193d06410b80","size":"17MB","target_guids":["4d2340a5-3042-3231-3030-304a57444644"],"type_of_change":"1","version":"HPD3","vib_list":[{"name":"CP048404","version":"HPD3.2-7.0.0.15843807"}]}],"id":{"product":"72ce2dc2a1214941a11d7ccaace19196","version":"9e3fa16a29f34288bd98e5691db27710"},"installation":{"command":"CP040682.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - MB012000JWDFD Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB012000JWDFDドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB012000JWDFD","target_guid":"4d2340a5-3042-3231-3030-304a57444644","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T03:05:23","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB012000JWDFD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]},{"key":"7800374","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"en","x_late":"This package contains utilities and libraries to enable HPE Storage fibre channel array connectivity on SUSE Linux Enterprise Server 15 for Emulex Host Bus Adapters and Mezzanine Host Bus Adapters"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1755295","datemodified":"2021-08-26T08:03:47","file_list":["./opt/emulex/sles15sp2/i386/lib/libdfc.so","./opt/emulex/sles15sp2/i386/lib/libdfc.so.12","./opt/emulex/sles15sp2/i386/lib/libdfc.so.12.8.526","./opt/emulex/sles15sp2/i386/lib/libemsdm.so","./opt/emulex/sles15sp2/i386/lib/libemulexhbaapi.so","./opt/emulex/sles15sp2/x86_64/lib64/libdfc.so","./opt/emulex/sles15sp2/x86_64/lib64/libdfc.so.12","./opt/emulex/sles15sp2/x86_64/lib64/libdfc.so.12.8.526","./opt/emulex/sles15sp2/x86_64/lib64/libemsdm.so","./opt/emulex/sles15sp2/x86_64/lib64/libemulexhbaapi.so","./usr/lib/libdfc.so","./usr/lib/libdfc.so.12","./usr/lib/libdfc.so.12.8.526","./usr/lib/libemsdm.so","./usr/lib/libemulexhbaapi.so","./usr/lib64/libdfc.so","./usr/lib64/libdfc.so.12","./usr/lib64/libdfc.so.12.8.526","./usr/lib64/libemsdm.so","./usr/lib64/libemulexhbaapi.so","./usr/share/smartupdate/HPE-CNA-FC-Emulex-Enablement-Kit/component.xml"],"md5sum":"4eb3695aae32f1dc44b894eb15caa838","name":"HPE-CNA-FC-Emulex-Enablement-Kit-12.8.526.0-1.sles15sp2.x86_64.rpm","release":"2021-08-26T07:57:04","revision":"0","sha1sum":"15f0949b07e067cca491ff01a954c2171e41bebb","size":"1MB","target_guids":[],"type_of_change":"0","version":"12.8.526.0"},{"bytes":"1755279","datemodified":"2021-08-26T08:04:59","file_list":["./opt/emulex/sles15sp3/i386/lib/libdfc.so","./opt/emulex/sles15sp3/i386/lib/libdfc.so.12","./opt/emulex/sles15sp3/i386/lib/libdfc.so.12.8.526","./opt/emulex/sles15sp3/i386/lib/libemsdm.so","./opt/emulex/sles15sp3/i386/lib/libemulexhbaapi.so","./opt/emulex/sles15sp3/x86_64/lib64/libdfc.so","./opt/emulex/sles15sp3/x86_64/lib64/libdfc.so.12","./opt/emulex/sles15sp3/x86_64/lib64/libdfc.so.12.8.526","./opt/emulex/sles15sp3/x86_64/lib64/libemsdm.so","./opt/emulex/sles15sp3/x86_64/lib64/libemulexhbaapi.so","./usr/lib/libdfc.so","./usr/lib/libdfc.so.12","./usr/lib/libdfc.so.12.8.526","./usr/lib/libemsdm.so","./usr/lib/libemulexhbaapi.so","./usr/lib64/libdfc.so","./usr/lib64/libdfc.so.12","./usr/lib64/libdfc.so.12.8.526","./usr/lib64/libemsdm.so","./usr/lib64/libemulexhbaapi.so","./usr/share/smartupdate/HPE-CNA-FC-Emulex-Enablement-Kit/component.xml"],"md5sum":"ee8fe589a7f44790f28cfe4fe7e8d3b2","name":"HPE-CNA-FC-Emulex-Enablement-Kit-12.8.526.0-1.sles15sp3.x86_64.rpm","release":"2021-08-26T07:57:04","revision":"0","sha1sum":"d309b5b9c782fc9d4eba5e58f9c204c057da8a70","size":"1MB","target_guids":[],"type_of_change":"0","version":"12.8.526.0"}],"id":{"product":"40ca2544bf4d4474a11cb36a10119b2f","version":"6d755d575b334446b2e06d9b5e5d961a"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The target environment must have the libHBAAPI Package installed prior to the installation of the enablement kit. (If not already present, the libHBAAPI Package can be obtained from the operating system installation media.)</p>\n\n<p>&nbsp;</p>\n\n<p>This version of the enablement kit does not provide the additional functionality of rebuilding the ram disk or setting driver parameters as the previous versions had done.&nbsp; Please refer to the &ldquo;Additional setup&rdquo; section of the Native Linux Device-Mapper Multipath for HPE StorageWorks Arrays reference guide for instructions on how to perform these functions.&nbsp; The reference guide is available at the following link:</p>\n\n<p><a href=\"http://www.hpe.com/storage/spock/\">http://www.hpe.com/storage/spock/</a></p>\n\n<p>Rewrite of same Enablement kit version on SuSE Linux Enterprise Server 15 service pack&nbsp;2 and SuSE Linux Enterprise Server 15 service pack&nbsp;3 has to be performed using --reinstall option</p>\n\n<p>Example:&nbsp;rpm &ndash;Uvh HPE-CNA-FC-Emulex-Enablement-Kit-&lt;version&gt;.&lt;OS&gt;.&lt;architecture&gt;.rpm --reinstall &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<p>&nbsp;For more information please refer the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex Fibre Channel Enablement Kit for Host Bus Adapters and Mezzanine Host Bus Adapters for SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"F100","subven":"10DF","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T10:35:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added the following support:</p>\n\n<ul>\n\t<li>Added support for SLES 15 SP3</li>\n</ul>\n\n<p>Updated to version 12.8.526.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"HPE-CNA-FC-Emulex-Enablement-Kit","sw_key_expectedpath":"software:rpm"},{"name":"HPE-CNA-FC-Emulex-Enablement-Kit","sw_key_expectedpath":"software:rpm"},{"name":"HPE-CNA-FC-Emulex-Enablement-Kit","sw_key_expectedpath":"software:rpm"},{"name":"HPE-CNA-FC-Emulex-Enablement-Kit","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Intel i40en Adapters running under VMware vSphere 6.7"},{"lang":"ja","x_late":"この製品は、VMware vSphere 6.7上で動作するHPE Intel i40enアダプターのためのドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;1.10.9.0.</p>\n"},{"lang":"ja","x_late":"<p>この製品には、ドライバーバージョン1.10.9.0が含まれています。</p>\n"}],"files":[{"bytes":"219351","datemodified":"2021-09-05T12:33:38","file_list":["/cp049457.xml","/Intel-i40en_1.10.9.0-1OEM.670.0.0.8169922-offline_bundle-16117660.zip","/Intel-i40en_1.10.9.0-1OEM.670.0.0.8169922-offline_bundle-16117660.zip/index.xml","/Intel-i40en_1.10.9.0-1OEM.670.0.0.8169922-offline_bundle-16117660.zip/vendor-index.xml","/Intel-i40en_1.10.9.0-1OEM.670.0.0.8169922-offline_bundle-16117660.zip/metadata.zip","/Intel-i40en_1.10.9.0-1OEM.670.0.0.8169922-offline_bundle-16117660.zip/vib20/i40en/INT_bootbank_i40en_1.10.9.0-1OEM.670.0.0.8169922.vib","/Intel-i40en_1.10.9.0-1OEM.670.0.0.8169922-offline_bundle-16117660.zip/metadata.zip/vendor-index.xml","/Intel-i40en_1.10.9.0-1OEM.670.0.0.8169922-offline_bundle-16117660.zip/metadata.zip/vmware.xml","/Intel-i40en_1.10.9.0-1OEM.670.0.0.8169922-offline_bundle-16117660.zip/metadata.zip/vibs/i40en-360149877953999718.xml","/Intel-i40en_1.10.9.0-1OEM.670.0.0.8169922-offline_bundle-16117660.zip/metadata.zip/bulletins/Intel-i40en_1.10.9.0-1OEM.670.0.0.8169922.xml"],"md5sum":"9bac15eb2d1ae980e81de4b41f88fc39","name":"cp049457.zip","release":"2021-09-05T12:29:41","revision":"0","sha1sum":"43d0a962be4185b0765fe0a104f6938fd79ee188","size":"214KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec17ceb7c3"],"type_of_change":"0","version":"2021.04.05","vib_list":[{"name":"i40en","version":"1.10.9.0-1OEM.670.0.0.8169922"}]}],"id":{"product":"cbfe1835cecf43e391be405d2fc118ca","version":"c35725b081314341b12e05850cdfe1f6"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel i40en Driver for VMware vSphere 6.7"},{"lang":"ja","x_late":"HPE Intel i40enドライバー for VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"},{"dev":"1572","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1572808600a1","type":"pci","ven":"8086"},{"dev":"1572","subdev":"0008","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-157280860008","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-10-02T12:56:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue obtain PCI addresses information when execution intnet CLI tools.</p>\n"},{"curr_enhancements_x_late":"<p>This product supports the following new server:</p>\n\n<ul>\n\t<li>HPE ProLiant DL360 Gen10 Plus Server</li>\n\t<li>HPE ProLiant DL380 Gen10 Plus Server&nbsp;</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"H10","value":"HPE Edgeline e920t Server"},{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920d Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"i40en:1.10.9.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6172504","datemodified":"2021-06-01T21:00:30","file_list":["/CP047378.vmexe","/CP047378.vmfile","/CP047378.xml","/README.txt"],"md5sum":"5ecc4a5ebe5c95161e98fc743ff40757","name":"CP047378.zip","release":"2021-06-02T01:57:26","revision":"0","sha1sum":"26ec690b683787e71aeff1b421832cfca121b464","size":"5MB","target_guids":[],"type_of_change":"1","version":"3.00_04-01-2021","vib_list":[]}],"id":{"product":"4c879b2de58c433090e3e0a088f41fb0","version":"b91078190137425fa17b2e39af7fe085"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component requires that the CRU driver be loaded before the component can run.<br />\nThe minimum CRU version for 5.5 is 5.5.4.1.<br />\nThe minimum CRU version for 6.0 is 6.0.8.<br />\nThe minimum CRU version for 6.5 is 6.5.8.</p>\n\n<p>The minimum CRU version for 6.7 is 6.7.10.<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>SPP Offline mode boots a special Linux OS environment, thus the Linux Components are used, not the VMware Components</li>\n</ul>\n\n<p><br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Download the appropriate SPP</li>\n\t<li>Add the component to the SPP</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run SUM</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps to complete the firmware update</li>\n\t<li>Refer to the SPP documentation for detailed instructions at:&nbsp; <a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Component ( CPxxxxxx.zip) in a temporary directory</li>\n\t<li>From the same directory, unzip the Component:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>To perform the standalone installation, execute the command:<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>Follow the directions given by the Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system for the firmware update to take effect</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、実行する前にCRUドライバーがロードされている必要があります。<br />\n5.5の最小CRUバージョンは5.5.4.1です。<br />\n6.0の最小CRUバージョンは6.0.8です。<br />\n6.5の最小CRUバージョンは6.5.8です。</p>\n\n<p>6.7の最小CRUバージョンは6.7.10です。<br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMwareコンポーネントではなく、Linuxコンポーネントが用いられます</li>\n</ul>\n\n<p><br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします</li>\n\t<li>SPPにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします</li>\n\t<li>SUMを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します</li>\n\t<li>SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います</li>\n\t<li>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>コンポーネント (CPxxxxxx.zip)を一時ディレクトリに置きます</li>\n\t<li>同じディレクトリからコンポーネントをunzipします:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>スタンドアロンのインストールを行うために、次のコマンドを実行します：<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>コンポーネントの指示に従います</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n\t<li>システムを再起動し、ファームウェアのアップデートを有効にします</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware - HPE ProLiant DL20 Gen9 (U22) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor VMware - HPE ProLiant DL20 Gen9 (U22)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"5","minor":"5","name":"VMware vSphere 5.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-26T07:15:08","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode: 0x000000E2 (CPUID 506E3). This Intel microcode patch provide mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-8696 and CVE-2020-8698. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00381. These issues are not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-24512. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-464. The Intel microcode patches included in this release are version 0x000000EA (CPUID 506E3 and CPUID 906E9). These issues are not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel sighting CVE-2020-24512. This security vulnerability is documented in Intel Security Advisory INTEL-SA-00463. The Intel microcode patches included in this release are version 0x000000EA (CPUID 506E3) and 0x000000EA (CPUID 906E9). This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-8670 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"}],"sw_keys":[{"name":"U22","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for HPE QLogic NX2 10/20 GbE Multifunction Adapters running under VMware vSphere 6.7."},{"lang":"ja","x_late":"この製品は、VMware vSphere 6.7上で動作するHPE QLogic NX2 10/20 GbEマルチファンクションアダプターのためのドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains the following drivers:</p>\n\n<ul>\n\t<li>qfle3, version 1.1.17.0</li>\n\t<li>qcnic, version 1.0.59.0</li>\n\t<li>qfle3i, version 1.1.5.0</li>\n\t<li>qfle3f, version 1.1.25.0</li>\n</ul>\n"}],"files":[{"bytes":"1400894","datemodified":"2021-08-11T13:57:38","file_list":["/cp047116.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip/index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip/metadata.zip","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip/vib20/qfle3f/QLC_bootbank_qfle3f_1.1.25.0-1OEM.670.0.0.8169922.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip/vib20/qfle3i/QLC_bootbank_qfle3i_1.1.5.0-1OEM.670.0.0.8169922.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip/vib20/qfle3/QLC_bootbank_qfle3_1.1.17.0-1OEM.670.0.0.8169922.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip/vib20/qcnic/QLC_bootbank_qcnic_1.0.59.0-1OEM.670.0.0.8169922.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip/metadata.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip/metadata.zip/vmware.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip/metadata.zip/vibs/qfle3f--2870239878310587039.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip/metadata.zip/vibs/qfle3i--6801888692139910757.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip/metadata.zip/vibs/qfle3--5362795065017542531.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip/metadata.zip/vibs/qcnic--558619672783143317.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip/metadata.zip/bulletins/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922.xml"],"md5sum":"c4f8a06e8aa33a71bb3fe306474a5b8a","name":"cp047116.zip","release":"2021-08-11T13:54:21","revision":"0","sha1sum":"eae9003a5f3e47a6d9acb9e073a89fd77d43a401","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecbba24fc7","20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","20a6e8e4-bf33-4c71-a6bf-d9eca261a1a0","20a6e8e4-bf33-4c71-a6bf-d9ec7339bbbe"],"type_of_change":"0","version":"2021.09.04","vib_list":[{"name":"qfle3f","version":"1.1.25.0-1OEM.670.0.0.8169922"},{"name":"qfle3i","version":"1.1.5.0-1OEM.670.0.0.8169922"},{"name":"qfle3","version":"1.1.17.0-1OEM.670.0.0.8169922"},{"name":"qcnic","version":"1.0.59.0-1OEM.670.0.0.8169922"}]}],"id":{"product":"c5169d515a774f51aa01a14f6284794f","version":"81e0439e57244eb3a575e9fa9ba36835"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic NX2 10/20 GbE Multifunction Driver for VMware vSphere 6.7"},{"lang":"ja","x_late":"VMware vSphere 6.7用HPE QLogic NX2 10/20 GbEマルチファンクションドライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"16AD","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16ad159000ec","type":"pci","ven":"1077"},{"dev":"168E","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c339d","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c18d3","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c193a","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1930","type":"pci","ven":"14E4"},{"dev":"16A1","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a1159000ec","type":"pci","ven":"1077"},{"dev":"16A4","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a4159000ec","type":"pci","ven":"1077"},{"dev":"168E","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-168e15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1931","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c339d","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c18d3","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c193a","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1930","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1931","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c339d","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c193a","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1930","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1931","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16af15908148","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ae15908148","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product addresses an issue about 536FLR-T adapter latency/link down when running a LiveCoreDump on vCenter.</p>\n"},{"curr_enhancements_x_late":"<p>This products enhances the mechanism that collation of data log.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"qcnic:1.0.59.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qfle3:1.1.17.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qfle3f:1.1.25.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qfle3i:1.1.5.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Mellanox CX3 Ethernet NICs for Windows Server 2012 R2."},{"lang":"ja","x_late":"このコンポーネントパッケージは、HPE Mellanox CX3 Ethernet NIC for Windows Server 2012 R2用のドライバーを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"18538408","datemodified":"2019-10-08T04:01:32","file_list":["cp040882.xml","cpqsetup.exe","cp_data.xml","ibbus.sys","install.xml","ipoib6x.cat","ipoib6x.inf","ipoib6x.sys","MLNX_VPI_WinOF-5_35_HP_win2012R2_x64.exe","mlx4eth63.cat","mlx4eth63.inf","mlx4eth63.sys","mlx4_bus.cat","mlx4_bus.inf","mlx4_bus.sys","mlx_setup.dll","ndfltr.sys","nicdrvr.dll","RestartDriver.exe","Tenable-Upgrade.ps1","winctxtune_bus.dll","winctxtune_eth.dll","winctxtune_ipoib.dll","winmad.sys","winverbs.sys"],"md5sum":"a75dc6db150a2adb363abf5ae3abc407","name":"cp040882.exe","release":"2019-10-08T03:46:02","revision":"0","sha1sum":"9bed88d49c6955d286c8df06468a6949eecb9013","size":"17MB","target_guids":[],"type_of_change":"0","version":"5.35.12978.0"}],"id":{"product":"3de1667723914ad89f6c44c12d89171b","version":"0ecf0c72db94499c82c18762aefa5a19"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"tw","x_late":"將智慧型元件下載至硬碟上的目錄，並變更至該目錄。<p>從該磁碟和目錄，執行下載的檔案。<p>按一下「Install」(安裝) 按鈕，繼續執行安裝程序。<br>"},{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ko","x_late":"스마트 구성 요소를 하드 드라이브의 디렉터리로 다운로드하고 그 디렉터리로 이동합니다.<p>드라이브와 디렉터리에서 다운로드한 파일을 실행합니다.<p>설치 버튼을 클릭하여 설치 작업을 시작합니다.<br>"},{"lang":"cn","x_late":"将智能组件下载到硬盘目录中，然后转至该目录。<p>在该硬盘目录中，执行下载的文件。<p>点击安装按钮继续执行安装。<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox CX3 Driver for Windows Server 2012 R2"},{"lang":"ja","x_late":"HPE Mellanox CX3ドライバーfor Windows Server 2012 R2"}],"prerequisites":{"required_diskspace":{"size_kb":"100"},"supported_devices":[{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"","type":"pci","ven":"15B3"},{"dev":"1004","subdev":"8020","subven":"103C","target_guid":"","type":"pci","ven":"15B3"},{"dev":"1004","subdev":"801F","subven":"103C","target_guid":"","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-11-08T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Fixed an issue where the link speed of an IPoIB adapter was the actual speed and not the official speed (i.e. 54.3GB/s instead of 56 GB/s).<br />\nFixed an issue where firmware burning failed on servers with Connectx-3 and Connectx-4 devices.<br />\nFixed an issue were Mellanox counters in Perfmon did not work over HPE devices.<br />\nFixed an issue that caused the installation process to hang while checking if the RDSH service is installed.<br />\nFixed an issue where a SR-IOV team failure was caused by an unsuccessful adapter parameters update.<br />\nFixed a crash in the driver properties dialog in the case where more than 8 teaming ports were defined.<br />\nFixed an issue which reported a false error for successful netsh tcp settings via performance tuning.<br />\nFixed a crash which could occur during virtual function initialization.<br />\nDeactivated the RDMA statistics counters query for vPorts for which RDMA is not enabled.<br />\nFixed the issue which caused the failure of the powershell command Get_MLNXNetAdapterSettings and the command Get_MLNXNetAdapterFlowControlSettings on servers with Connectx3/Pro and ConnectX4/LX devices.<br />\nFixed a crash which could occur during driver initialization.<br />\nFixed an issue that generated and sent an erroneous message to the Windows event log when using firmware 2.36.5000 whenever &quot;Mellanox WinOF Bus Counters&quot; was selected in Perfmon.<br />\nFixed an issue that occasionally caused system-hang when TCP offload parameters were updated dynamically while SR-IOV was enabled.<br />\nFixed an issue that occasionally caused system-hang upon bus driver disabling, when the encapsulation parameters were updated dynamically while SR-IOV was enabled.<br />\nFixed an issue where the virtual function RDMA was not functional when vSwitch was attached to port 2. Now RDMA over VF is supported only when the vSwitch is attached to port 1.<br />\nFixed an issue which caused the driver to hang during installation process.</p>\n"},{"curr_enhancements_x_late":"<p>This product now remove&nbsp;supports Synergy and Blade&nbsp;Server.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"}],"sw_keys":[{"name":"mlx4_bus.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG0600JETKA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SED8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3630-304a45544b41","Version":"HPD8"},{"DeviceName":"EG0900JETKB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SED8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3930-304a45544b42","Version":"HPD8"},{"DeviceName":"EG1200JETKC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SED8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3230-304a45544b43","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EG0600JETKA, EG0900JETKB and EG1200JETKC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG0600JETKA,&nbsp;EG0900JETKB&nbsp;and&nbsp;EG1200JETKC Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"16005366","datemodified":"2021-08-30T05:29:09","file_list":["/CP048264_BUILD_2.data","/CP048264.vmexe","/CP048264.vmexe64","/CP048264.vmfile","/CP048264_VMw.zip","/CP048264.xml","/payload.json","/CP048264_VMw.zip/index.xml","/CP048264_VMw.zip/vendor-index.xml","/CP048264_VMw.zip/metadata.zip","/CP048264_VMw.zip/vib20/CP048264/HPE_bootbank_CP048264_HPD8.2-7.0.0.15843807.vib","/CP048264_VMw.zip/metadata.zip/vendor-index.xml","/CP048264_VMw.zip/metadata.zip/vmware.xml","/CP048264_VMw.zip/metadata.zip/vibs/CP048264--66723586510665876.xml","/CP048264_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048264_HPD8.2-7.0.0.15843807.xml"],"md5sum":"dfdaadd427878ddbed2480e56c92863a","name":"CP048264.zip","release":"2021-08-30T05:24:36","revision":"0","sha1sum":"810eacd21a019163e318038aa793f096d9f7b28d","size":"15MB","target_guids":["002340a5-4500-3047-3630-304a45544b41","002340a5-4500-3047-3930-304a45544b42","002340a5-4500-3147-3230-304a45544b43"],"type_of_change":"1","version":"HPD8","vib_list":[{"name":"CP048264","version":"HPD8.2-7.0.0.15843807"}]}],"id":{"product":"d5fee9f753d04f3ba9583fdfe0002842","version":"42c35874b46445528a6b19861c62437e"},"installation":{"command":"CP040504.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - EG0600JETKA, EG0900JETKB and EG1200JETKC Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EG0600JETKA、EG0900JETKB、およびEG1200JETKCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG1200JETKC","target_guid":"002340a5-4500-3147-3230-304a45544b43","type":"sas"},{"id":"EG0600JETKA","target_guid":"002340a5-4500-3047-3630-304a45544b41","type":"sas"},{"id":"EG0900JETKB","target_guid":"002340a5-4500-3047-3930-304a45544b42","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-02T11:02:23","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>A low-probability, high severity corner case of sustained outer-diameter activity with emergency power off when heads are at the outer diameter prevented heads from parking/latching properly on a few drives in the field.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG0900JETKB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG1200JETKC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0600JETKA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900374","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware and boot BIOS of Emulex Mezzanine Fibre Channel host bus adapters."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5396143","datemodified":"2021-08-25T12:58:05","file_list":["/CP048576_BUILD_4.data","/CP048576.vmexe","/CP048576.vmexe64","/CP048576.vmfile","/CP048576_VMw.zip","/CP048576.xml","/payload.json","/CP048576_VMw.zip/index.xml","/CP048576_VMw.zip/vendor-index.xml","/CP048576_VMw.zip/metadata.zip","/CP048576_VMw.zip/vib20/CP048576/HPE_bootbank_CP048576_2021.10.01.4-6.5.0.4240417.vib","/CP048576_VMw.zip/metadata.zip/vendor-index.xml","/CP048576_VMw.zip/metadata.zip/vmware.xml","/CP048576_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048576_2021.10.01.4-6.5.0.4240417.xml","/CP048576_VMw.zip/metadata.zip/vibs/CP048576--7259053899492861850.xml"],"md5sum":"a4bf9d20f665172e6a6a0bf3b3333476","name":"CP048576.zip","release":"2021-08-25T12:52:06","revision":"0","sha1sum":"c3c3c93191f037eb56ceb8d45c6289b1a6b72c49","size":"5MB","target_guids":[],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"CP048576","version":"2021.10.01.4-6.5.0.4240417"}]}],"id":{"product":"8a8ad9e527cc4273a877d32ee6fff804","version":"afa1bc2e03264119b8f6778e42e7cfcf"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated if the ESXi host is Gen9 Server or Enter the IP or DNS address of the iLO of the ESXi host if the Sever is Gen10 and above</li>\n\t<li>Enter the ESXi host/iLO credentials (root or administrator username and password) based on Gen9/Gen10 and above</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Mezzanine Fibre Channel Host Bus Adapters for VMware vSphere  6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"20000"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T09:15:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This Firmware package contains following firmware versions:&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 16Gb LPe1605 Fibre Channel Host Bus Adapter for BladeSystem c-Class</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>12.8.528.12</td>\n\t\t\t<td>12.8.528.12</td>\n\t\t\t<td>12.8.528.10</td>\n\t\t\t<td>12.8.502.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"emulex","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11400032","languages":[{"lang":"tw","x_late":"應用程式 - 系統管理"},{"lang":"en","x_late":"Application - System Management"},{"lang":"ko","x_late":"응용 프로그램 - 시스템 관리"},{"lang":"ja","x_late":"アプリケーション - システム マネジメント"},{"lang":"cn","x_late":"应用程序 - 系统管理"}]}],"description":[{"lang":"en","x_late":"Integrated Smart Update Tools (iSUT) is an application which enables firmware and software deployment via the iLO management network using the server’s local administrator credentials. iSUT can run as a service when working with HPE OneView managed servers or iLO Amplifier Pack or in an On Demand mode. iSUT requires a Service Pack for ProLiant-based ISO containing Smart Update Manager version 8.0.0 or later and an iLO Advanced Pack license for deployment."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]}],"documentation":[],"files":[{"bytes":"14002472","datemodified":"2021-09-07T12:04:42","file_list":["CHIF/","CHIF/X64/","cp039984.exe","cp039985.exe","cp040013.exe","cp041932.exe","cp046870.xml","cp049467.exe","cpqsetup.exe","cp_data.xml","HPSUT/","HPSUT/X64/","install.xml","multisetup.dll","sut.msi","sutinstaller.exe","sut_cfg_default.dat","sut_config_en.xml","sut_config_ja.xml"],"md5sum":"4c0c0d82064400bbbbeb49a3c0069a8d","name":"cp046870.exe","release":"2021-09-07T12:01:07","revision":"0","sha1sum":"607e322569cb80a1a2f3880178d0209229e8e09d","size":"13MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5f36672a","20a6e8e4-bf33-4c71-a6bf-d9ec4db0e49b"],"type_of_change":"1","version":"2.9.0.0"}],"id":{"product":"8fe22752c5324386870794853904b4ba","version":"8a0b3156be774e96a56aea3bb1f92f0e"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<ol>\n\t<li>Download the Smart Component (cpxxxxxx.exe) file to a local directory on the server where you want to install the software.</li>\n\t<li>Change to the directory.</li>\n\t<li>Run the .exe file by double-clicking it. A dialog box will display.</li>\n\t<li>Click the &lsquo;Install&rsquo; button to install the Smart Update Tools.</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Integrated Smart Update Tools for Windows x64"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_devices":[{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3307103c3381","type":"pci","ven":"103C"},{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3306103c3381","type":"pci","ven":"103C"},{"dev":"3308","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3308103c3381","type":"pci","ven":"103C"},{"dev":"3300","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3300103c3381","type":"pci","ven":"103C"},{"dev":"3301","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3301103c3381","type":"pci","ven":"103C"},{"dev":"3302","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3302103c3381","type":"pci","ven":"103C"},{"dev":"3306","subdev":"1979","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3306103c1979","type":"pci","ven":"103C"},{"dev":"3307","subdev":"1979","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3307103c1979","type":"pci","ven":"103C"},{"dev":"3307","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3307159000e4","type":"pci","ven":"103C"},{"dev":"3307","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3306159000e4","type":"pci","ven":"103C"},{"dev":"3306","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"027F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-33061590027f","type":"pci","ven":"103C"},{"dev":"3307","subdev":"027F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-33071590027f","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-08T06:47:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>See the&nbsp;<a href=\"http://www.hpe.com/info/sut-docs\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>\n","latest_fixes_x_late":"<p>See the&nbsp;<a href=\"http://www.hpe.com/info/sut-docs\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>\n"},{"curr_enhancements_x_late":"<p>See the&nbsp;<a href=\"http://www.hpe.com/info/sut-docs\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>\n","curr_fixes_x_late":"<p>See the&nbsp;<a href=\"http://www.hpe.com/info/sut-docs\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"","value":"HP Smart Update Tools (HP SUT)"},{"key":"U26","value":"HPE ProLiant Easy Connect EC200a Managed Hybrid Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U24","value":"HPE ProLiant XL2x260w Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"hpsut.exe","sw_key_expectedpath":"%ProgramFiles%\\Hewlett-Packard\\HPSUT\\bin"},{"name":"sut.exe","sw_key_expectedpath":"%ProgramFiles%\\SUT\\bin"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"本產品包含 Red Hat Enterprise Linux 7 x86_64 下執行的 HPE Intel ixgbe 乙太網路 NIC 驅動程式。"},{"lang":"en","x_late":"This product contains the drivers for the HPE Intel ixgbe Ethernet NICs running under Red Hat Enterprise Linux 7 x86_64."},{"lang":"ko","x_late":"이 제품에는 Red Hat Enterprise Linux 7 x86_64에서 실행되는 HPE Intel ixgbe 이더넷 NIC용 드라이버가 포함되어 있습니다."},{"lang":"cn","x_late":"本产品包含适用于在 Red Hat Enterprise Linux 7 x86_64 下方运行的 HPE Intel ixgbe 以太网网卡驱动程序。"},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7 x86_64で動作するHPE Intel ixgbe Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"202280","datemodified":"2021-01-09T00:14:28","file_list":["./etc/depmod.d/hp-ixgbe.conf","./etc/dracut.conf.d/hp-ixgbe-oob.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/hp-ixgbe","./lib/modules/3.10.0-1160.el7.x86_64/extra/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/kmod-hp-ixgbe/component.xml"],"md5sum":"61f4611c61d36905f4775f5b570e10d2","name":"kmod-hp-ixgbe-5.9.4-1.rhel7u9.x86_64.rpm","release":"2021-01-08T23:59:05","revision":"0","sha1sum":"17bf7ef8e17eb1fd81d13a89b7559658d18699d8","size":"197KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccba99d79"],"type_of_change":"0","version":"5.9.4-1"},{"bytes":"202282","datemodified":"2021-01-09T00:19:31","file_list":["./etc/depmod.d/hp-ixgbe.conf","./etc/dracut.conf.d/hp-ixgbe-oob.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/hp-ixgbe","./lib/modules/3.10.0-1127.el7.x86_64/extra/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/kmod-hp-ixgbe/component.xml"],"md5sum":"d32087f4889606ded4ccefc7bfee7fb1","name":"kmod-hp-ixgbe-5.9.4-1.rhel7u8.x86_64.rpm","release":"2021-01-08T23:59:05","revision":"0","sha1sum":"db880252d9d93e8bd6f04022f15d6934bb08efe2","size":"197KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccba99d79"],"type_of_change":"0","version":"5.9.4-1"}],"id":{"product":"e2ded6c100dc4bec88c153fd9c85c964","version":"58bbcff8f5434dfb94e18c4a5443a13d"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>Download README for any additional installation instructions.</p>\n"},{"lang":"ja","x_late":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>\n\n<p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>\n\n<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>\n\n<p> </p>\n\n<p>その他のインストール手順についてのREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 Red Hat Enterprise Linux 7 x86_64 的 HPE Intel ixgbe 驅動程式"},{"lang":"en","x_late":"HPE Intel ixgbe Drivers for Red Hat Enterprise Linux 7 x86_64"},{"lang":"ko","x_late":"Red Hat Enterprise Linux 7 x86_64용 HPE Intel ixgbe 드라이버"},{"lang":"cn","x_late":"适用于 Red Hat Enterprise Linux 7 x86_64 的 HPE Intel ixgbe 驱动程序"},{"lang":"ja","x_late":"HPE Intel ixgbeドライバー for Red Hat Enterprise Linux 7 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c192d","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c211a","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"},{"dev":"152E","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d3","type":"pci","ven":"8086"},{"dev":"1530","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"1515","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c192d","type":"pci","ven":"8086"},{"dev":"1515","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c211a","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue where the patched kernel symbol changed on PTP (Precision Time Protocol) module.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>This product now supports Red Hat Enterprise Linux 7 update 9</li>\n\t<li>This product enhances reliability via adding support for new mailbox communication between PF(Physical Function) and VF(Virtual Function) and remove its potential flaws that may lead to the undefined or faulty behavior</li>\n\t<li>This product enhances compatibility where new mailbox api implementation is alo compatible with old drivers</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-hp-ixgbe","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbe","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbe","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbe","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB1000GVYZE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3142-3030-304756595a45","Version":"HPG4"},{"DeviceName":"MB2000GVYZF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304756595a46","Version":"HPG4"},{"DeviceName":"MB3000GVYZH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304756595a48","Version":"HPG4"},{"DeviceName":"MB4000GVYZK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304756595a4b","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB1000GVYZE, MB2000GVYZF, MB3000GVYZH and MB4000GVYZK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB1000GVYZE, MB2000GVYZF, MB3000GVYZH&nbsp;and MB4000GVYZK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"17008974","datemodified":"2021-08-26T17:53:15","file_list":["/CP048343_BUILD_2.data","/CP048343.vmexe","/CP048343.vmexe64","/CP048343.vmfile","/CP048343_VMw.zip","/CP048343.xml","/payload.json","/CP048343_VMw.zip/index.xml","/CP048343_VMw.zip/vendor-index.xml","/CP048343_VMw.zip/metadata.zip","/CP048343_VMw.zip/vib20/CP048343/HPE_bootbank_CP048343_HPG4.2-7.0.0.15843807.vib","/CP048343_VMw.zip/metadata.zip/vendor-index.xml","/CP048343_VMw.zip/metadata.zip/vmware.xml","/CP048343_VMw.zip/metadata.zip/vibs/CP048343--7999903424607054505.xml","/CP048343_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048343_HPG4.2-7.0.0.15843807.xml"],"md5sum":"c0dbbb83bd1fa5344e42419986bbf4d2","name":"CP048343.zip","release":"2021-08-26T17:47:06","revision":"0","sha1sum":"d7915a4aaca254081e2f7ab79402ca0b6d16e8bf","size":"16MB","target_guids":["002340a5-4d00-3142-3030-304756595a45","002340a5-4d00-3242-3030-304756595a46","002340a5-4d00-3342-3030-304756595a48","002340a5-4d00-3442-3030-304756595a4b"],"type_of_change":"1","version":"HPG4","vib_list":[{"name":"CP048343","version":"HPG4.2-7.0.0.15843807"}]}],"id":{"product":"c33dcf4fcf5847ada8c87d0479b6cb3a","version":"471a1c101b27456b99abe7bdb3adc4c0"},"installation":{"command":"CP040554.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB1000GVYZE, MB2000GVYZF, MB3000GVYZH and MB4000GVYZK Drives"},{"lang":"ja","x_late":"オンラインHDD/SDDフラッシュコンポーネントfor VMware ESXi - MB1000GVYZE、MB2000GVYZF、MB3000GVYZH、およびMB4000GVYZKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB1000GVYZE","target_guid":"002340a5-4d00-3142-3030-304756595a45","type":"sata"},{"id":"MB2000GVYZF","target_guid":"002340a5-4d00-3242-3030-304756595a46","type":"sata"},{"id":"MB3000GVYZH","target_guid":"002340a5-4d00-3342-3030-304756595a48","type":"sata"},{"id":"MB4000GVYZK","target_guid":"002340a5-4d00-3442-3030-304756595a4b","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-06T15:51:33","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB3000GVYZH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB2000GVYZF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB1000GVYZE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB4000GVYZK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000JEFRB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVNGSD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-304a45465242","Version":"HPD9"},{"DeviceName":"MM2000JEFRC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVNGSD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-324d-3030-304a45465243","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MM1000JEFRB and MM2000JEFRC"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MM1000JEFRBおよびMM2000JEFRC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MM1000JEFRB and MM2000JEFRC Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD7</p>\n\n<p><br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3590048","datemodified":"2021-07-25T17:24:58","file_list":["cp048625.xml","cpqsetup.exe","payload.json","SAVNGSD9.rel","setup.dll"],"md5sum":"e737f595ea9b4e6e2d6798ce047e728d","name":"cp048625.exe","release":"2021-07-25T17:17:05","revision":"0","sha1sum":"d87507b044faf5880b6bbe7e6adf59e85cb7b95b","size":"3MB","target_guids":["002340a5-4d00-314d-3030-304a45465242","002340a5-4d00-324d-3030-304a45465243"],"type_of_change":"1","version":"HPD9"}],"id":{"product":"182450d5bced417a85db3271254808a7","version":"3e6deed46b464f8fb7a11b8f469da1f3"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MM1000JEFRB and MM2000JEFRC Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MM1000JEFRBおよびMM2000JEFRCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MM1000JEFRB","target_guid":"002340a5-4d00-314d-3030-304a45465242","type":"sas"},{"id":"MM2000JEFRC","target_guid":"002340a5-4d00-324d-3030-304a45465243","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T13:25:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MM2000JEFRC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MM1000JEFRB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"此元件套件包含適用於 Windows Server 2016. 的 HPE Mellanox CX3 Ethernet NIC 驅動程式。"},{"lang":"en","x_late":"This Component Package contains the driver for HPE Mellanox CX3 Ethernet NICs for Windows Server 2016."},{"lang":"ko","x_late":"이 구성 요소 패키지에는 Windows Server 2016용 HPE Mellanox CX3 이더넷 NIC에 사용할 수 있는 드라이버가 포함되어 있습니다."},{"lang":"cn","x_late":"该组件包内含面向Windows Server 2016的HPE Mellanox CX3以太网网卡驱动程序。"},{"lang":"ja","x_late":"このコンポーネントパッケージは、HPE Mellanox CX3 Ethernet NIC for Windows Server 2016用のドライバーを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"18458896","datemodified":"2019-10-08T04:23:44","file_list":["cp040866.xml","cpqsetup.exe","cp_data.xml","ibbus.sys","install.xml","ipoib6x.cat","ipoib6x.inf","ipoib6x.sys","MLNX_VPI_WinOF-5_35_HP_win2016_x64.exe","mlx4eth63.cat","mlx4eth63.inf","mlx4eth63.sys","mlx4_bus.cat","mlx4_bus.inf","mlx4_bus.sys","mlx_setup.dll","ndfltr.sys","nicdrvr.dll","RestartDriver.exe","Tenable-Upgrade.ps1","winctxtune_bus.dll","winctxtune_eth.dll","winctxtune_ipoib.dll","winmad.sys","winverbs.sys"],"md5sum":"b220f0690db3002afa6b4474d1086ea9","name":"cp040866.exe","release":"2019-10-08T04:08:02","revision":"0","sha1sum":"75a861b9027084526b5b891aba07d5e836a3aa5e","size":"17MB","target_guids":[],"type_of_change":"0","version":"5.35.12978.0"}],"id":{"product":"99585b9bf89c4f4eb41d039eef8811c2","version":"cacefc2d3dc3479fafb26a7c8438c4f5"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Windows Server 2016 的 HPE Mellanox CX3 驅動程式"},{"lang":"en","x_late":"HPE Mellanox CX3 Driver for Windows Server 2016"},{"lang":"ko","x_late":"Windows Server 2016용 HPE Mellanox CX3 드라이버"},{"lang":"cn","x_late":"用于Windows Server 2016的HPE Mellanox CX3驱动程序"},{"lang":"ja","x_late":"HPE Mellanox CX3ドライバー for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"100"},"supported_devices":[{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"","type":"pci","ven":"15B3"},{"dev":"1004","subdev":"8020","subven":"103C","target_guid":"","type":"pci","ven":"15B3"},{"dev":"1004","subdev":"801F","subven":"103C","target_guid":"","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-11-08T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product restores support for the following network adapters:</p>\n\n<ul>\n\t<li>HP Ethernet 10G 2-port 546FLR-SFP+ Adapter</li>\n\t<li>HP Ethernet 10G 2-port 546SFP+ Adapter</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now remove&nbsp;supports Synergy and Blade&nbsp;Server.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"}],"sw_keys":[{"name":"mlx4_bus.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB1000JVYZL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3142-3030-304a56595a4c","Version":"HPD3"},{"DeviceName":"MB2000JVYZN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a56595a4e","Version":"HPD3"},{"DeviceName":"MB3000JVYZP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304a56595a50","Version":"HPD3"},{"DeviceName":"MB4000JVYZQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a56595a51","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB1000JVYZL, MB2000JVYZN, MB3000JVYZP and MB4000JVYZQ"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB1000JVYZL、MB2000JVYZN、MB3000JVYZPおよびMB4000JVYZQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB1000JVYZL, MB2000JVYZN, MB3000JVYZP and MB4000JVYZQ Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"5459421","datemodified":"2021-07-23T06:08:53","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b85516c7d2-HPD3-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-b85516c7d2-HPD3-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b85516c7d2-HPD3-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b85516c7d2-HPD3-6.1/CP048147.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b85516c7d2-HPD3-6.1/SMBPNSD3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-b85516c7d2-HPD3-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b85516c7d2-HPD3-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b85516c7d2-HPD3-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b85516c7d2-HPD3-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048147.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048147.scexe"],"md5sum":"cff5c86432022543e133fd40009f636b","name":"firmware-hdd-b85516c7d2-HPD3-6.1.x86_64.rpm","release":"2021-07-23T05:57:05","revision":"0","sha1sum":"2f4f75c0b6d0279c2b2d750b75dda7dc6642282e","size":"5MB","target_guids":["002340a5-4d00-3142-3030-304a56595a4c","002340a5-4d00-3242-3030-304a56595a4e","002340a5-4d00-3342-3030-304a56595a50","002340a5-4d00-3442-3030-304a56595a51"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"94af0b81860b4d31a8cc9f27961f4ea0","version":"c9673cea5256465d8afadf1dc1ecea7d"},"installation":{"command":"CP040343.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB1000JVYZL, MB2000JVYZN, MB3000JVYZP and MB4000JVYZQ Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB1000JVYZL、MB2000JVYZN、MB3000JVYZP、およびMB4000JVYZQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB1000JVYZL","target_guid":"002340a5-4d00-3142-3030-304a56595a4c","type":"sas"},{"id":"MB2000JVYZN","target_guid":"002340a5-4d00-3242-3030-304a56595a4e","type":"sas"},{"id":"MB3000JVYZP","target_guid":"002340a5-4d00-3342-3030-304a56595a50","type":"sas"},{"id":"MB4000JVYZQ","target_guid":"002340a5-4d00-3442-3030-304a56595a51","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-26T18:41:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB1000JVYZL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB2000JVYZN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB3000JVYZP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB4000JVYZQ","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB002000GWFGH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SNEMOTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757464748","Version":"HPG3"},{"DeviceName":"MB001000GWFGF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SNEMOTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757464746","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB002000GWFGH and MB001000GWFGF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB002000GWFGH and MB001000GWFGF Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Added support for RHEL 8.4 and SLES15SP3.</p>\n\t</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5148570","datemodified":"2021-07-23T08:01:06","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-0b575b5895-HPG3-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-0b575b5895-HPG3-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-0b575b5895-HPG3-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-0b575b5895-HPG3-8.1/CP048096.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-0b575b5895-HPG3-8.1/SNEMOTG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-0b575b5895-HPG3-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-0b575b5895-HPG3-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-0b575b5895-HPG3-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-0b575b5895-HPG3-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048096.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048096.scexe"],"md5sum":"d55e2b4fd4a5a502fbd728620aec9864","name":"firmware-hdd-0b575b5895-HPG3-8.1.x86_64.rpm","release":"2021-07-23T07:48:08","revision":"0","sha1sum":"f4eecdd56b3d5d4fee8463ddbd9bd2390dcd7794","size":"4MB","target_guids":["4d2340a5-3042-3230-3030-304757464748","4d2340a5-3042-3130-3030-304757464746"],"type_of_change":"0","version":"HPG3"}],"id":{"product":"81e371ec59e54de18ebca5fd69821033","version":"927a5a6d7d1f4ece98ee102e09ad55af"},"installation":{"command":"CP040332.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB002000GWFGH and MB001000GWFGF Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB002000GWFGHおよびMB001000GWFGFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB001000GWFGF","target_guid":"4d2340a5-3042-3130-3030-304757464746","type":"sata"},{"id":"MB002000GWFGH","target_guid":"4d2340a5-3042-3230-3030-304757464748","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T12:26:01","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB001000GWFGF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB002000GWFGH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800026","languages":[{"lang":"tw","x_late":"軟體 - 管理"},{"lang":"en","x_late":"Software - Management"},{"lang":"ko","x_late":"소프트웨어 - 관리"},{"lang":"ja","x_late":"ソフトウェア - マネジメント"},{"lang":"cn","x_late":"软件 - 管理"}]}],"description":[{"lang":"en","x_late":"The HPE ESXi Management Smart Component for ESXi 6.7 includes the latest HPE Common Information Model (CIM) Providers, HPE Integrated Lights-Out (iLO) driver, HPE Compaq ROM Utility (CRU) driver, the HPE Agentless Management Service (AMS), and Fibre Channel(FC) HBA access libraries."},{"lang":"ja","x_late":"HPE ESXiマネジメントSmartコンポーネントfor ESXi 6.7には、最新のHPE Common Information Model (CIM) Provider、HPE Integrated Lights-Out (iLO)ドライバー、HPE Compaq ROM Utility (CRU)ドライバー、HPE Agentless Management Service (AMS)、およびファイバーチャネル (FC) HBAアクセスライブラリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"29872120","datemodified":"2021-09-07T18:40:17","file_list":["/cp049078.xml","/esxi6.7uX-mgmt-bundle-gen9.3.8.0.12-1.zip","/esxi6.7uX-mgmt-bundle-gen9.3.8.0.12-1.zip/index.xml","/esxi6.7uX-mgmt-bundle-gen9.3.8.0.12-1.zip/vendor-index.xml","/esxi6.7uX-mgmt-bundle-gen9.3.8.0.12-1.zip/metadata-esxi6.7uX-mgmt-bundle-gen9.3.8.0.12-1.zip","/esxi6.7uX-mgmt-bundle-gen9.3.8.0.12-1.zip/amshelpr-670.11.8.0.8-1.7535516.vib","/esxi6.7uX-mgmt-bundle-gen9.3.8.0.12-1.zip/smx-provider-670.03.16.00.3-7535516.vib","/esxi6.7uX-mgmt-bundle-gen9.3.8.0.12-1.zip/ilo_670.10.7.5.2-1OEM.670.0.0.7535516.vib","/esxi6.7uX-mgmt-bundle-gen9.3.8.0.12-1.zip/fc-enablement-670.3.80.6-7535516.vib","/esxi6.7uX-mgmt-bundle-gen9.3.8.0.12-1.zip/cru_670.6.7.10.14-1OEM.670.0.0.7535516.vib","/esxi6.7uX-mgmt-bundle-gen9.3.8.0.12-1.zip/metadata-esxi6.7uX-mgmt-bundle-gen9.3.8.0.12-1.zip/vendor-index.xml","/esxi6.7uX-mgmt-bundle-gen9.3.8.0.12-1.zip/metadata-esxi6.7uX-mgmt-bundle-gen9.3.8.0.12-1.zip/vmware.xml","/esxi6.7uX-mgmt-bundle-gen9.3.8.0.12-1.zip/metadata-esxi6.7uX-mgmt-bundle-gen9.3.8.0.12-1.zip/vibs/amshelpr--7123005248586460367.xml","/esxi6.7uX-mgmt-bundle-gen9.3.8.0.12-1.zip/metadata-esxi6.7uX-mgmt-bundle-gen9.3.8.0.12-1.zip/vibs/smx-provider--6253706443730693861.xml","/esxi6.7uX-mgmt-bundle-gen9.3.8.0.12-1.zip/metadata-esxi6.7uX-mgmt-bundle-gen9.3.8.0.12-1.zip/vibs/ilo-2964936189223017316.xml","/esxi6.7uX-mgmt-bundle-gen9.3.8.0.12-1.zip/metadata-esxi6.7uX-mgmt-bundle-gen9.3.8.0.12-1.zip/vibs/fc-enablement-8460638345289256901.xml","/esxi6.7uX-mgmt-bundle-gen9.3.8.0.12-1.zip/metadata-esxi6.7uX-mgmt-bundle-gen9.3.8.0.12-1.zip/vibs/cru--1581854872647123919.xml","/esxi6.7uX-mgmt-bundle-gen9.3.8.0.12-1.zip/metadata-esxi6.7uX-mgmt-bundle-gen9.3.8.0.12-1.zip/bulletins/esxi6.7uX-mgmt-bundle-gen9.3.8.0.12-1.xml"],"md5sum":"0a16c5cc01679ca2d311468a26dd769c","name":"cp049078.zip","release":"2021-09-07T18:36:09","revision":"0","sha1sum":"8a949c252cbcb129fd825c7d16e2f4ca62f5d185","size":"28MB","target_guids":[],"type_of_change":"1","version":"2021.10.00","vib_list":[{"name":"amshelpr","version":"670.11.8.0.8-1.7535516"},{"name":"smx-provider","version":"670.03.16.00.3-7535516"},{"name":"ilo","version":"670.10.7.5.2-1OEM.670.0.0.7535516"},{"name":"fc-enablement","version":"670.3.80.6-7535516"},{"name":"cru","version":"670.6.7.10.14-1OEM.670.0.0.7535516"}]}],"id":{"product":"424586858da54235abb9a96e632bc309","version":"370ecb3201f84884a35b572b19ca7c31"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To&nbsp;remotely install&nbsp;this&nbsp;bundle&nbsp; online using the HP Smart Update Manager (HPSUM) from the HP Service Pack for ProLiant (SPP):</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"http://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=8788688&amp;lang=en&amp;cc=us\">HP USB Key Creator Utility</a>.</li>\n\t<li>Copy&nbsp;this driver component&nbsp;to the directory<em> /SPP20xxxxx/hp/swpackages</em> on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.</li>\n\t<li>Change directories to <em>/hp/swpackages</em> and execute&nbsp;./hpsum.</li>\n\t<li>Select the &quot;next&quot; button.</li>\n\t<li>Click &quot;Add Single Target.&quot;</li>\n\t<li>Enter&nbsp;the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow HP Smart Update Manager&nbsp;instructions&nbsp;to complete the driver update.</li>\n</ol>\n\n<p><br />\n<strong>To&nbsp;install this bundle using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the component zip file to extract the driver offline bundle.</li>\n\t<li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li>\n</ol>\n\n<p>Refer to VMware documentation for information on the esxcli commands</p>\n"},{"lang":"ja","x_late":"<p><strong>HP Service Pack for ProLiant (SPP)からHP Smart Update Manager (HPSUM)を使用して、このバンドルをオンラインでリモートインストールするには：</strong></p>\n\n<ol>\n\t<li><a href=\"http://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=8788688&lang=en&cc=us\">HP USB Key Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>このドライバーコンポーネントをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。</li>\n\t<li><em>/hp/swpackages</em>にディレクトリを変更し、./hpsumを実行します。</li>\n\t<li>「次へ」ボタンを選択します。</li>\n\t<li>「シングルターゲットの追加」をクリックします。</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>HP Smart Update Manager 手順に従って、ドライバーアップデートを完了します。</li>\n</ol>\n\n<p><br />\n<strong>VMwareツールを使用して、このバンドルをインストールするには：</strong></p>\n\n<ol>\n\t<li>ドライバーオフラインバンドルを抽出するために、このコンポーネントのzipファイルを解凍します。</li>\n\t<li>オフラインバンドルをインストールするには、「esxcli」コマンドを実行します。</li>\n</ol>\n\n<p>esxcliコマンドの詳細については、VMwareのドキュメントを参照してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Management Bundle Smart Component for ESXi 6.7 for Gen9 Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"31000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-10-18T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Agentless Management Service</strong></p>\n\n<ul>\n\t<li>Added support for new NIC devices (Gen10 AMS only)</li>\n\t<li>Added support for new&nbsp;SATA, SAS and NVMe drives (Gen10 AMS only)</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Agentless Management Service</strong></p>\n\n<ul>\n\t<li>Reduce Software Inventory cache refresh time&nbsp;to 15 seconds to help resolve OneView online SW update issues without reboot.</li>\n\t<li>Fixed resource leak when AHS logging fails</li>\n\t<li>Fix incorrect reporting of SATA disks attached to Smart Array and SAS controllers in the&nbsp;cpqIdeAtaDisk MIB.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Agentless Management Service</strong></p>\n\n<ul>\n\t<li>Applied fixes to net-snmp open source code for CVE-2018-18065, CVE-2018-18066, CVE-2015-5621</li>\n</ul>\n\n<p><strong>iLO Driver</strong></p>\n\n<ul>\n\t<li>Fixed driver unload function to allow controller to function properly on reload and when Quickboot is enabled</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"H05","value":"HPE ProLiant m510 Server Blade"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"H07","value":"HPE ProLiant m710x Server Blade"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"H07","value":"HPE ProLiant m710x-L Server Blade"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"fc-enablement:670.3.80.6-7535516","sw_key_expectedpath":"software:vmware:zip"},{"name":"smx-provider:670.03.16.00.3-7535516","sw_key_expectedpath":"software:vmware:zip"},{"name":"cru:670.6.7.10.14-1OEM.670.0.0.7535516","sw_key_expectedpath":"driver:vmware:zip"},{"name":"amshelpr:670.11.8.0.8-1.7535516","sw_key_expectedpath":"software:vmware:zip"},{"name":"ilo:670.10.7.5.2-1OEM.670.0.0.7535516","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox adapter cards."},{"lang":"ja","x_late":"このRPMには、サポートされているHPE Mellanoxアダプターカード用のHPEによるテストと承認済みのLinuxベースMellanox RoCE (RDMA over Converged Ethernet)ドライバーが含まれます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1933691","datemodified":"2021-05-17T21:33:00","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/connectx.conf","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d/mlx4.driver","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/security/limits.d/30-libvma-limits.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/82-net-setup-link.rules","./etc/udev/rules.d/90-ib.rules","./sbin/connectx_port_config","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/ibdev2netdev","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_get_vfs.pl","./usr/bin/mlnx_perf","./usr/bin/mlnx_qcn","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/lib/python2.7/site-packages/dcbnetlink.py","./usr/lib/python2.7/site-packages/dcbnetlink.pyc","./usr/lib/python2.7/site-packages/dcbnetlink.pyo","./usr/lib/python2.7/site-packages/genetlink.py","./usr/lib/python2.7/site-packages/genetlink.pyc","./usr/lib/python2.7/site-packages/genetlink.pyo","./usr/lib/python2.7/site-packages/netlink.py","./usr/lib/python2.7/site-packages/netlink.pyc","./usr/lib/python2.7/site-packages/netlink.pyo","./usr/lib/python2.7/site-packages/ofed_le_utils-1.0.3-py2.7.egg-info","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/vma.service","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.0","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.0.0","./usr/lib64/libmlx4-rdmav2.so","./usr/lib64/libmlx5-rdmav2.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.0.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.0.0","./usr/lib64/libvma-debug.so","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.0.2","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vma","./usr/sbin/vmad","./usr/share/doc/packages/ib2ib","./usr/share/doc/packages/ib2ib/README","./usr/share/doc/packages/libibumad","./usr/share/doc/packages/libibumad/AUTHORS","./usr/share/doc/packages/libibumad/COPYING","./usr/share/doc/packages/libibumad/ChangeLog","./usr/share/doc/packages/libibverbs","./usr/share/doc/packages/libibverbs/AUTHORS","./usr/share/doc/packages/libibverbs/COPYING","./usr/share/doc/packages/libibverbs/ChangeLog","./usr/share/doc/packages/libibverbs/README","./usr/share/doc/packages/libmlx4","./usr/share/doc/packages/libmlx4/AUTHORS","./usr/share/doc/packages/libmlx4/COPYING","./usr/share/doc/packages/libmlx4/README","./usr/share/doc/packages/libmlx5","./usr/share/doc/packages/libmlx5/AUTHORS","./usr/share/doc/packages/libmlx5/COPYING","./usr/share/doc/packages/libmlx5/README","./usr/share/doc/packages/librdmacm","./usr/share/doc/packages/librdmacm/AUTHORS","./usr/share/doc/packages/librdmacm/COPYING","./usr/share/doc/packages/librdmacm/README","./usr/share/doc/packages/libvma-9.0.2/README.txt","./usr/share/doc/packages/libvma-9.0.2/VMA_VERSION","./usr/share/doc/packages/libvma-9.0.2/journal.txt","./usr/share/man/man3/umad_addr_dump.3.gz","./usr/share/man/man3/umad_alloc.3.gz","./usr/share/man/man3/umad_attribute_str.3.gz","./usr/share/man/man3/umad_class_str.3.gz","./usr/share/man/man3/umad_close_port.3.gz","./usr/share/man/man3/umad_debug.3.gz","./usr/share/man/man3/umad_done.3.gz","./usr/share/man/man3/umad_dump.3.gz","./usr/share/man/man3/umad_free.3.gz","./usr/share/man/man3/umad_free_ca_namelist.3.gz","./usr/share/man/man3/umad_get_ca.3.gz","./usr/share/man/man3/umad_get_ca_namelist.3.gz","./usr/share/man/man3/umad_get_ca_portguids.3.gz","./usr/share/man/man3/umad_get_cas_names.3.gz","./usr/share/man/man3/umad_get_fd.3.gz","./usr/share/man/man3/umad_get_issm_path.3.gz","./usr/share/man/man3/umad_get_mad.3.gz","./usr/share/man/man3/umad_get_mad_addr.3.gz","./usr/share/man/man3/umad_get_pkey.3.gz","./usr/share/man/man3/umad_get_port.3.gz","./usr/share/man/man3/umad_init.3.gz","./usr/share/man/man3/umad_mad_status_str.3.gz","./usr/share/man/man3/umad_method_str.3.gz","./usr/share/man/man3/umad_open_port.3.gz","./usr/share/man/man3/umad_poll.3.gz","./usr/share/man/man3/umad_recv.3.gz","./usr/share/man/man3/umad_register.3.gz","./usr/share/man/man3/umad_register2.3.gz","./usr/share/man/man3/umad_register_oui.3.gz","./usr/share/man/man3/umad_release_ca.3.gz","./usr/share/man/man3/umad_release_port.3.gz","./usr/share/man/man3/umad_send.3.gz","./usr/share/man/man3/umad_set_addr.3.gz","./usr/share/man/man3/umad_set_addr_net.3.gz","./usr/share/man/man3/umad_set_grh.3.gz","./usr/share/man/man3/umad_set_grh_net.3.gz","./usr/share/man/man3/umad_set_pkey.3.gz","./usr/share/man/man3/umad_size.3.gz","./usr/share/man/man3/umad_status.3.gz","./usr/share/man/man3/umad_unregister.3.gz","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml"],"md5sum":"83d56342c1a07e2672d3d40bd9339a0b","name":"mlnx-ofa_kernel-4.9-OFED.4.9.3.1.6.1.sles12sp4.x86_64.rpm","release":"2021-05-17T20:36:08","revision":"0","sha1sum":"8baf532792eb1bd3adae1fdc942f86bf864566c4","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5"],"type_of_change":"1","version":"4.9"},{"bytes":"1923586","datemodified":"2021-05-17T21:35:50","file_list":["./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/compat","./lib/modules/4.12.14-94.41-default/updates/compat/mlx_compat.ko","./lib/modules/4.12.14-94.41-default/updates/drivers","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/ib_cm.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/ib_core.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/ib_ucm.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/ib_umad.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/iw_cm.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/rdma_cm.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/cxgb3","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/cxgb3/iw_cxgb3.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/cxgb4","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/efa","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/efa/efa.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/hfi1","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/i40iw","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/mlx4","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/mlx5","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/mthca","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/mthca/ib_mthca.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/nes","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/nes/iw_nes.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/ocrdma","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/ocrdma/ocrdma.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/qedr","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/qib","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/qib/ib_qib.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/usnic","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/sw","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/sw/rdmavt","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/sw/rxe","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/ipoib","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/iser","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/isert","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/opa_vnic","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/srp","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/srpt","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/net","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlx4","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlx4/mlx4_core.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlx4/mlx4_en.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlx5","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlx5/fpga","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlx5/fpga/mlx5_fpga_tools.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/nvme","./lib/modules/4.12.14-94.41-default/updates/drivers/nvme/host","./lib/modules/4.12.14-94.41-default/updates/drivers/nvme/host/nvme-rdma.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/nvme/target","./lib/modules/4.12.14-94.41-default/updates/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/4.12.14-94.41-default/updates/net","./lib/modules/4.12.14-94.41-default/updates/net/9p","./lib/modules/4.12.14-94.41-default/updates/net/9p/9pnet_rdma.ko","./lib/modules/4.12.14-94.41-default/updates/net/rds","./lib/modules/4.12.14-94.41-default/updates/net/rds/rds_rdma.ko","./lib/modules/4.12.14-94.41-default/updates/net/sunrpc","./lib/modules/4.12.14-94.41-default/updates/net/sunrpc/xprtrdma","./lib/modules/4.12.14-94.41-default/updates/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/4.12.14-94.41-default/updates/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/4.12.14-94.41-default/updates/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/mlnx-ofa_kernel-kmp-default/component.xml"],"md5sum":"dfd13ed2db8a36b9e88b43bcaf35e169","name":"mlnx-ofa_kernel-kmp-default-4.9_k4.12.14_94.41-OFED.4.9.3.1.6.1.sles12sp4.x86_64.rpm","release":"2021-05-17T20:36:08","revision":"0","sha1sum":"754cbe251822fbc46c895d329f945b4e72efa20c","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5"],"type_of_change":"1","version":"4.9"}],"id":{"product":"eff3fb3bc296490cb954337b0cfc0052","version":"74c0c3e901694d60808847ea597ff9f1"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"11.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPMs to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-4.9&quot; RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using 4.12.14-94.41-default kernel or any future errata:<br />\n<br />\n<strong># rpm -Uvh&nbsp;mlnx-ofa_kernel-4.9-OFED.4.9.3.1.6.1.sles12sp4.x86_64.rpm&nbsp;mlnx-ofa_kernel-kmp-default-4.9_k4.12.14_94.41-OFED.4.9.3.1.6.1.sles12sp4.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for SUSE LINUX Enterprise Server 12 SP4 (AMD64/EM64T)"},{"lang":"ja","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) ドライバーfor SUSE LINUX Enterprise Server 12 SP4 (AMD64/EM64T)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-17T16:51:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>The following changes and new features are added in version 4.9:</strong></p>\n\n<ul>\n\t<li><strong>For ConnectX-5 Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Option to dump configuration space via the devlink tool in order to improve debug capabilities.</li>\n\t<li>The conventional TX descriptor (WQE or Work Queue Element) describes a single packet for transmission. Added driver support for the HW feature of multi-packet TX WQEs in XDP transmit flows. With this, the HW becomes capable of working with a new and improved WQE layout that describes several packets. In effect, this feature saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>GENEVE encapsulation/decapsulation rules offload.</li>\n\t<li>Driver support for the hardware feature of multi-packet Tx to work with a new and improved WQE layout that describes several packets instead of a single packet for XDP transmission flows. This saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>Updating CT (Connection Tracking) rules using the software steering mechanism.</li>\n\t<li>Updating remote mirroring rules using the software steering mechanism.<br />\n\t&nbsp;</li>\n\t<li><strong>For ConnectX-4&nbsp;Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Exposed rx_prio[p]_discards discard counters per priority that count the number of received packets dropped due to lack of buffers on the physical port.</li>\n\t<li>Reporting TSO and CSUM offload capabilities for MPLS tagged traffic and, allowed the kernel stack to use these offloads.</li>\n\t<li>mlx5e Max Combined Channels Increased the driver&rsquo;s maximal combined channels value from 64 to 128 (however, note that OOB value will not cross 64). 128 is the upper bound. Lower maximal value can be seen on the host, depending on the number of cores and MSIX&#39;s configured by the firmware.</li>\n\t<li>Added the following RoCE accelerator counters:\n\t<ul>\n\t\t<li>roce_adp_retrans - counts the number of adaptive retransmissions for RoCE traffic.</li>\n\t\t<li>roce_adp_retrans_to - counts the number of times RoCE traffic reached timeout due to adaptive retransmission.</li>\n\t\t<li>roce_slow_restart - counts the number of times RoCE slow restart was used.</li>\n\t\t<li>roce_slow_restart_cnps - counts the number of times RoCE slow restart generated CNP packets roce_slow_restart_trans - counts the number of times RoCE slow restart changed state to slow restart.</li>\n\t</ul>\n\t</li>\n\t<li>User to register memory regions with a relaxed ordering access flag through experimental verbs. This can enhance performance, depending on architecture and scenario.<br />\n\t&nbsp;</li>\n\t<li><strong>For&nbsp;All HCA&#39;s</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Output ibdev2netdev tool output was changed such that the bonding device now points at the bond instead of the slave interface.</li>\n\t<li>Monitoring and recovering from errors that occur on the RX queue, such as cookie errors and timeout.</li>\n\t<li>Improved GSO (Generic Segmentation Offload) workload performance by decreasing doorbells usage to the minimum required.</li>\n\t<li>TX CQE (Completion Queue Element) compression. Saves on outgoing PCIe bandwidth by compressing CQEs together. Disabled by default. Configurable via private flags of ethtool.</li>\n\t<li>Firmware Versions Query via Devlink :Added the option to query for running and stored firmware versions using the devlink tool.</li>\n\t<li>Firmware Flash Update via Devlink :Added the option to update the firmware image in the flash using the devlink tool. Usage: devlink dev flash file .mfa2 For further information on how to perform this update, see &quot;Updating Firmware Using ethtool/devlink and .mfa2 File&quot; section in MFT User Manual.</li>\n\t<li>WQE (Work Queue Element) dump, triggered by an error on Rx/Tx reporters. In addition, some dumps (not triggered by an error) can be retrieved by the user via devlink health reporters.</li>\n\t<li>GENEVE tunneled hardware offloads of TSO, CSUM and RSS.</li>\n\t<li>TCP segmentation and checksum offload support for MPLS-tagged traffic.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 4.9:</strong></p>\n\n<ul>\n\t<li>An issue where injecting EEH (Extended Error Handlng) may cause extra Kernel prints, such as: &ldquo;EEH: Might be infinite loop in mlx5_core driver&rdquo; was fixed.</li>\n\t<li>RPM-based OSs with non-default kernels, using repositories after re-creating the installer (using --add-kernel-support) were&nbsp;resulting&nbsp;in improper installation of the drivers.</li>\n\t<li>A typo in perftest package where help messages wrongly displayed the conversion result between Gb/s and MB/s (20^2 instead of 2^20).</li>\n\t<li>When one of the LAG slaves went down, LAG deactivation failed, ultimately causing bandwidth degradation.</li>\n\t<li>The mlx5 driver maintains a subdirectory for every open eth port in /sys/kernel/debug/. For the default network namespace, the sub-directory name is the name of the interface, like &quot;eth8&quot;. The new convention for the network interfaces moved to the non-default network namespaces is the interfaces name followed by &quot;@&quot; and the port&#39;s PCI ID. For example: &quot;eth8@0000:af:00.3&quot;.</li>\n\t<li>&quot;openibd&quot; script load used to fail when esp6_offload module did not load successfully.</li>\n\t<li>Added dependency of package mpi-selectors on perl-Getopt-Long system package. On minimal installs of RPM-based OSs, installing mpi-selectros will also install the required system package perl-Getopt-Long.</li>\n\t<li>During certain rare scenarios, due to Rx page not being replenished, the same page fragment mistakenly became assigned to two different Rx descriptors.</li>\n\t<li>Driver load issue existed with Errata-kernel on SLES15 SP1.</li>\n\t<li>An issue in the Hairpin feature which prevented adding hairpin flows using TC tool was fixed.</li>\n\t<li>WQ (Work Queue)&nbsp;queue flushing was not handled properly in the event of EEH.</li>\n\t<li>A rare kernel crash scenario when exiting an application that uses RMPP mads intensively.</li>\n\t<li>A possible kernel crash scenario when AER/slot reset in done in parallel to user space commands execution.</li>\n\t<li>Added missing ECN (Explicit Congestion Notification) configuration under sysfs for PFs in SwitchDev mode.</li>\n\t<li>When firmware response time to commands became very long, some commands failed upon timeout. The driver may have then triggered a timeout completion on the wrong entry, leading to a NULL pointer call trace.</li>\n\t<li>Added driver support for kernels with the old XDP_REDIRECT infrastructure that uses the following NetDev operations: .ndo_xdp_flush and .ndo_xdp_xmit.</li>\n\t<li>Usage of --excludedocs Open MPI RPM option resulted in the removal of non-documentation related files.</li>\n\t<li>Disabled automated loading of some modules through udev triggers to preserve the startup process of previous MLNX_OFED versions.</li>\n\t<li>Reference count (refcount) for RDMA connection ID (cm_id) was not incremented in rdma_resolve_addr() function, resulting in a cm_id use-after-free access. A fix was applied to increment the cm_id refcount</li>\n\t<li>A race condition which caused kernel panic when moving two ports to SwitchDev mode at the same time.</li>\n\t<li>Allowed accessing sysfs hardware counters in SwitchDev mode</li>\n\t<li>Function smp_processor_id() is called in the RX page recycle flow to determine the core to run on. This is intended to run in NAPI context. However, due to a bug in backporting, the RX page recycle was mistakenly called also in the RQ close flow when not needed.</li>\n\t<li>Port link state was automatically changed (without admin state involvement) to &quot;UP&quot; after reboot.</li>\n\t<li>ConnectX-3 adapter cards froze when running over SLES 11 OS.</li>\n\t<li>RDMA CM (Remote Direct Memory Access Communation Manager) connection failed when port space was small.</li>\n\t<li>Traffic mirroring with OVS (Open VSwitch)offload and non-offload over VxLAN interface is now supported. Note: For kernel 4.9, make sure to use a dedicated OVS version.</li>\n\t<li>When working with VF LAG while the bond device is in active-active mode, running fwreset would result in unequal traffic on both PFs, and PFs would not reach line rate.</li>\n\t<li>When bond was created over VF (Virtuaal Function)&nbsp;netdevices in SwitchDev mode, the VF netdevice would be treated as representor netdevice. This caused the mlx5_core driver to crash in case it received netdevice events related to bond device.</li>\n\t<li>An issue where following a bad affinity occurrence in VF LAG mode, traffic was sent after the port went up/down in the switch.</li>\n\t<li>Added support for VLAN (Virtual Local Area Network)&nbsp;header rewrite on CentOS 7.2 OS.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>The following changes and new features are added in version 4.9:</strong></p>\n\n<ul>\n\t<li><strong>For ConnectX-5 Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Option to dump configuration space via the devlink tool in order to improve debug capabilities.</li>\n\t<li>The conventional TX descriptor (WQE or Work Queue Element) describes a single packet for transmission. Added driver support for the HW feature of multi-packet TX WQEs in XDP transmit flows. With this, the HW becomes capable of working with a new and improved WQE layout that describes several packets. In effect, this feature saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>GENEVE encapsulation/decapsulation rules offload.</li>\n\t<li>Driver support for the hardware feature of multi-packet Tx to work with a new and improved WQE layout that describes several packets instead of a single packet for XDP transmission flows. This saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>Updating CT (Connection Tracking) rules using the software steering mechanism.</li>\n\t<li>Updating remote mirroring rules using the software steering mechanism.<br />\n\t&nbsp;</li>\n\t<li><strong>For ConnectX-4&nbsp;Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Exposed rx_prio[p]_discards discard counters per priority that count the number of received packets dropped due to lack of buffers on the physical port.</li>\n\t<li>Reporting TSO and CSUM offload capabilities for MPLS tagged traffic and, allowed the kernel stack to use these offloads.</li>\n\t<li>mlx5e Max Combined Channels Increased the driver&rsquo;s maximal combined channels value from 64 to 128 (however, note that OOB value will not cross 64). 128 is the upper bound. Lower maximal value can be seen on the host, depending on the number of cores and MSIX&#39;s configured by the firmware.</li>\n\t<li>Added the following RoCE accelerator counters:\n\t<ul>\n\t\t<li>roce_adp_retrans - counts the number of adaptive retransmissions for RoCE traffic.</li>\n\t\t<li>roce_adp_retrans_to - counts the number of times RoCE traffic reached timeout due to adaptive retransmission.</li>\n\t\t<li>roce_slow_restart - counts the number of times RoCE slow restart was used.</li>\n\t\t<li>roce_slow_restart_cnps - counts the number of times RoCE slow restart generated CNP packets roce_slow_restart_trans - counts the number of times RoCE slow restart changed state to slow restart.</li>\n\t</ul>\n\t</li>\n\t<li>User to register memory regions with a relaxed ordering access flag through experimental verbs. This can enhance performance, depending on architecture and scenario.<br />\n\t&nbsp;</li>\n\t<li><strong>For&nbsp;All HCA&#39;s</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Output ibdev2netdev tool output was changed such that the bonding device now points at the bond instead of the slave interface.</li>\n\t<li>Monitoring and recovering from errors that occur on the RX queue, such as cookie errors and timeout.</li>\n\t<li>Improved GSO (Generic Segmentation Offload) workload performance by decreasing doorbells usage to the minimum required.</li>\n\t<li>TX CQE (Completion Queue Element) compression. Saves on outgoing PCIe bandwidth by compressing CQEs together. Disabled by default. Configurable via private flags of ethtool.</li>\n\t<li>Firmware Versions Query via Devlink :Added the option to query for running and stored firmware versions using the devlink tool.</li>\n\t<li>Firmware Flash Update via Devlink :Added the option to update the firmware image in the flash using the devlink tool. Usage: devlink dev flash file .mfa2 For further information on how to perform this update, see &quot;Updating Firmware Using ethtool/devlink and .mfa2 File&quot; section in MFT User Manual.</li>\n\t<li>WQE (Work Queue Element) dump, triggered by an error on Rx/Tx reporters. In addition, some dumps (not triggered by an error) can be retrieved by the user via devlink health reporters.</li>\n\t<li>GENEVE tunneled hardware offloads of TSO, CSUM and RSS.</li>\n\t<li>TCP segmentation and checksum offload support for MPLS-tagged traffic.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 4.9:</strong></p>\n\n<ul>\n\t<li>An issue where injecting EEH (Extended Error Handlng) may cause extra Kernel prints, such as: &ldquo;EEH: Might be infinite loop in mlx5_core driver&rdquo; was fixed.</li>\n\t<li>RPM-based OSs with non-default kernels, using repositories after re-creating the installer (using --add-kernel-support) were&nbsp;resulting&nbsp;in improper installation of the drivers.</li>\n\t<li>A typo in perftest package where help messages wrongly displayed the conversion result between Gb/s and MB/s (20^2 instead of 2^20).</li>\n\t<li>When one of the LAG slaves went down, LAG deactivation failed, ultimately causing bandwidth degradation.</li>\n\t<li>The mlx5 driver maintains a subdirectory for every open eth port in /sys/kernel/debug/. For the default network namespace, the sub-directory name is the name of the interface, like &quot;eth8&quot;. The new convention for the network interfaces moved to the non-default network namespaces is the interfaces name followed by &quot;@&quot; and the port&#39;s PCI ID. For example: &quot;eth8@0000:af:00.3&quot;.</li>\n\t<li>&quot;openibd&quot; script load used to fail when esp6_offload module did not load successfully.</li>\n\t<li>Added dependency of package mpi-selectors on perl-Getopt-Long system package. On minimal installs of RPM-based OSs, installing mpi-selectros will also install the required system package perl-Getopt-Long.</li>\n\t<li>During certain rare scenarios, due to Rx page not being replenished, the same page fragment mistakenly became assigned to two different Rx descriptors.</li>\n\t<li>Driver load issue existed with Errata-kernel on SLES15 SP1.</li>\n\t<li>An issue in the Hairpin feature which prevented adding hairpin flows using TC tool was fixed.</li>\n\t<li>WQ (Work Queue)&nbsp;queue flushing was not handled properly in the event of EEH.</li>\n\t<li>A rare kernel crash scenario when exiting an application that uses RMPP mads intensively.</li>\n\t<li>A possible kernel crash scenario when AER/slot reset in done in parallel to user space commands execution.</li>\n\t<li>Added missing ECN (Explicit Congestion Notification) configuration under sysfs for PFs in SwitchDev mode.</li>\n\t<li>When firmware response time to commands became very long, some commands failed upon timeout. The driver may have then triggered a timeout completion on the wrong entry, leading to a NULL pointer call trace.</li>\n\t<li>Added driver support for kernels with the old XDP_REDIRECT infrastructure that uses the following NetDev operations: .ndo_xdp_flush and .ndo_xdp_xmit.</li>\n\t<li>Usage of --excludedocs Open MPI RPM option resulted in the removal of non-documentation related files.</li>\n\t<li>Disabled automated loading of some modules through udev triggers to preserve the startup process of previous MLNX_OFED versions.</li>\n\t<li>Reference count (refcount) for RDMA connection ID (cm_id) was not incremented in rdma_resolve_addr() function, resulting in a cm_id use-after-free access. A fix was applied to increment the cm_id refcount</li>\n\t<li>A race condition which caused kernel panic when moving two ports to SwitchDev mode at the same time.</li>\n\t<li>Allowed accessing sysfs hardware counters in SwitchDev mode</li>\n\t<li>Function smp_processor_id() is called in the RX page recycle flow to determine the core to run on. This is intended to run in NAPI context. However, due to a bug in backporting, the RX page recycle was mistakenly called also in the RQ close flow when not needed.</li>\n\t<li>Port link state was automatically changed (without admin state involvement) to &quot;UP&quot; after reboot.</li>\n\t<li>ConnectX-3 adapter cards froze when running over SLES 11 OS.</li>\n\t<li>RDMA CM (Remote Direct Memory Access Communation Manager) connection failed when port space was small.</li>\n\t<li>Traffic mirroring with OVS (Open VSwitch)offload and non-offload over VxLAN interface is now supported. Note: For kernel 4.9, make sure to use a dedicated OVS version.</li>\n\t<li>When working with VF LAG while the bond device is in active-active mode, running fwreset would result in unequal traffic on both PFs, and PFs would not reach line rate.</li>\n\t<li>When bond was created over VF (Virtuaal Function)&nbsp;netdevices in SwitchDev mode, the VF netdevice would be treated as representor netdevice. This caused the mlx5_core driver to crash in case it received netdevice events related to bond device.</li>\n\t<li>An issue where following a bad affinity occurrence in VF LAG mode, traffic was sent after the port went up/down in the switch.</li>\n\t<li>Added support for VLAN (Virtual Local Area Network)&nbsp;header rewrite on CentOS 7.2 OS.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000GEFQV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGRTG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-304745465156","Version":"HPG8"},{"DeviceName":"MM2000GEFRA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGRTG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-324d-3030-304745465241","Version":"HPG8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MM1000GEFQV and MM2000GEFRA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MM1000GEFQV and MM2000GEFRA Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG5<br />\n<br />\n<strong>Previous Version of Firmware:<br />\n&nbsp; &nbsp; &nbsp; </strong>HPG5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"17368518","datemodified":"2021-08-27T06:30:32","file_list":["/CP048388_BUILD_2.data","/CP048388.vmexe","/CP048388.vmexe64","/CP048388.vmfile","/CP048388_VMw.zip","/CP048388.xml","/payload.json","/CP048388_VMw.zip/index.xml","/CP048388_VMw.zip/vendor-index.xml","/CP048388_VMw.zip/metadata.zip","/CP048388_VMw.zip/vib20/CP048388/HPE_bootbank_CP048388_HPG8.2-7.0.0.15843807.vib","/CP048388_VMw.zip/metadata.zip/vendor-index.xml","/CP048388_VMw.zip/metadata.zip/vmware.xml","/CP048388_VMw.zip/metadata.zip/vibs/CP048388--3199225999192389564.xml","/CP048388_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048388_HPG8.2-7.0.0.15843807.xml"],"md5sum":"dc8c4d78a03c252a1fda176f0215548a","name":"CP048388.zip","release":"2021-08-27T06:25:41","revision":"0","sha1sum":"97f084091a8c81a65c59cd6440750df4bfedb1e1","size":"16MB","target_guids":["002340a5-4d00-314d-3030-304745465156","002340a5-4d00-324d-3030-304745465241"],"type_of_change":"1","version":"HPG8","vib_list":[{"name":"CP048388","version":"HPG8.2-7.0.0.15843807"}]}],"id":{"product":"c19eee3c7a1046a4aeaff35e462fce56","version":"95103eef97df471cbb28099d4693e588"},"installation":{"command":"CP040658.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MM1000GEFQV and MM2000GEFRA Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MM1000GEFQVおよびMM2000GEFRAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MM1000GEFQV","target_guid":"002340a5-4d00-314d-3030-304745465156","type":"sata"},{"id":"MM2000GEFRA","target_guid":"002340a5-4d00-324d-3030-304745465241","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T10:15:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MM1000GEFQV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MM2000GEFRA","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWRTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLPeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757525443","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB008000GWRTC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB008000GWRTC Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4162280","datemodified":"2021-07-23T12:50:34","file_list":["cp048669.xml","cpqsetup.exe","HVLPeAaseFG1.rel","payload.json","setup.dll"],"md5sum":"8e80fd97ab5c8248faddc31980e90f87","name":"cp048669.exe","release":"2021-07-23T12:43:06","revision":"0","sha1sum":"5669200d4be0e781850b7e8dcee4c397dda105d2","size":"3MB","target_guids":["4d2340a5-3042-3830-3030-304757525443"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"92d9bf17d9ef471e842a80e42a41ec72","version":"0e752a2b01ad46b3a7ceae87ec4bfd22"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB008000GWRTC Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB008000GWRTCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB008000GWRTC","target_guid":"4d2340a5-3042-3830-3030-304757525443","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-17T08:16:26","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000GWRTC","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"QLogic driver for VMware vSphere 6.5"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1538710","datemodified":"2021-08-27T03:21:28","file_list":["/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip","/cp048721.xml","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/qlnativefc-2.1.101.0-1OEM.600.0.0.2768847.x86_64.vib","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/doc/README.txt","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/doc/release_note_qlnativefc_2.1.101.0-1OEM.600.0.0.2768847.txt","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/index.xml","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/vendor-index.xml","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/metadata.zip","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/vib20/qlnativefc/QLogic_bootbank_qlnativefc_2.1.101.0-1OEM.600.0.0.2768847.vib","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/metadata.zip/vmware.xml","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/metadata.zip/bulletins/VMW-ESX-6.0.0-qlnativefc-2.1.101.0.xml","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/metadata.zip/vibs/qlnativefc--7247954598143724648.xml"],"md5sum":"baa781172ed0670899956c52a3f3402b","name":"cp048721.zip","release":"2021-08-27T03:20:41","revision":"0","sha1sum":"212714ca6a2c38bfe96f0633b645aa1a16ab41ba","size":"1MB","target_guids":[],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"qlnativefc","version":"2.1.101.0-1OEM.600.0.0.2768847"}]}],"id":{"product":"e6d618b98f3b42608d68441707ef2433","version":"8c3faf7b26d444f2a72a44d215f22adc"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware&nbsp;vSphere Update Manager&nbsp;or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VMware&nbsp;vSphere Update Manager and the esxcli commands</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic Fibre Channel driver component for VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015D","subven":"1077","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015C","subven":"1077","target_guid":"","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-18T06:47:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Made improvements to the Fabric Port Identification Number (FPIN) and Universal Storage Area Network (SAN) Congestion Mitigation(USCM) Congestion Management algorithm</li>\n\t<li>\n\t<p>Implemented the vmkmgmt Application programming Interface (API) to report Non-Volatile Memory Express (NVMe) target info and send Non-Volatile Memory Express (NVMe) pass through commands</p>\n\t</li>\n</ul>\n\n<p>Driver version 2.1.101.0</p>\n","curr_fixes_x_late":"<ul>\n\t<li>\n\t<p dir=\"LTR\">Fixed an unwanted behavior where Get Port Speed Capabilities (GPSC) failures were leading to intelligent interleaved direct memory access (IIDMA) for target being set to 1GB/s. This is described in <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00115969en_us\">Advisory: HPE Host Bus Adapters - HPE Platforms Running VMware ESXi 6.5 / 6/7 / 7.0 and Configured With Certain HPE Host Bus Adapters May Experience Severe Performance Degradation When Connected to Brocade FOS v8.0.1 (or Prior)</a></p>\n\t</li>\n\t<li>Addressed unwanted behavior with Fabric Port Identification Number (FPIN) based congestion throttling leading to poor performance.</li>\n\t<li>Fixed an unwanted behavior where stale connection IDs could be used with Fibre Channel- Non Volatile Memory Express (FC-NVMe) traffic.</li>\n\t<li>\n\t<p>Fixed an unwanted behavior with response queue handling to avoid the problem referenced by <a href=\"https://kb.vmware.com/s/article/81721\">https://kb.vmware.com/s/article/81721</a></p>\n\t</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"qlnativefc:2.1.101.0-1OEM.600.0.0.2768847","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5700-764285-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F4","Version":"2.42.5700"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5056-764283-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F2","Version":"2.42.5056"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5056-764284-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F3","Version":"2.42.5056"},{"DeviceName":"HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5000-764286-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F5","Version":"2.42.5000"},{"DeviceName":"HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5000-764282-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F1","Version":"2.42.5000"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Mellanox VPI (Ethernet and Infiniband mode of operation) adapter firmware on VMware ESXi 6.7"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>InfiniBand Card Type</strong></td>\n\t\t\t<td><strong>Firmware&nbsp;Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+M Adapter (764282-B21)</td>\n\t\t\t<td>2.42.5000</td>\n\t\t\t<td>HP_1350110023</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+M Adapter (764283-B21)</td>\n\t\t\t<td>2.42.5056</td>\n\t\t\t<td>HP_1360110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+QSFP Adapter (764284-B21)</td>\n\t\t\t<td>2.42.5056</td>\n\t\t\t<td>HP_1370110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+FLR-QSFP Adapter (764285-B21)</td>\n\t\t\t<td>2.42.5700</td>\n\t\t\t<td>HP_1380110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+FLR-QSFP Adapter (764286-B21)</td>\n\t\t\t<td>2.42.5000</td>\n\t\t\t<td>HP_1390110023</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"19187482","datemodified":"2021-02-03T03:34:06","file_list":["/CP045903.vmexe","/CP045903.vmfile","/CP045903_VMw.zip","/CP045903.xml","/payload.json","/README.txt","/CP045903_VMw.zip/index.xml","/CP045903_VMw.zip/vendor-index.xml","/CP045903_VMw.zip/metadata.zip","/CP045903_VMw.zip/vib20/CP045903/HPE_bootbank_CP045903_1.0.1-6.7.0.7535516.vib","/CP045903_VMw.zip/metadata.zip/vendor-index.xml","/CP045903_VMw.zip/metadata.zip/vmware.xml","/CP045903_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045903_1.0.1-6.7.0.7535516.xml","/CP045903_VMw.zip/metadata.zip/vibs/CP045903-815716802762803397.xml"],"md5sum":"d6025d11031c1568d8eab8b71bb3ff06","name":"CP045903.zip","release":"2021-02-03T03:39:04","revision":"0","sha1sum":"f8d1daa1a0a32987ed82d774010a14b96cf560f9","size":"18MB","target_guids":["a6b1a447-382a-5a4f-15B3-1007103C22F4","a6b1a447-382a-5a4f-15B3-1007103C22F2","a6b1a447-382a-5a4f-15B3-1007103C22F3","a6b1a447-382a-5a4f-15B3-1007103C22F5","a6b1a447-382a-5a4f-15B3-1007103C22F1"],"type_of_change":"1","version":"1.0.5","vib_list":[{"name":"CP045903","version":"1.0.1-6.7.0.7535516"}]}],"id":{"product":"67519506663b4d259181b3f43ca2db43","version":"86f9d0e7891b4a37a4f6e38fd32f7de6"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Offline: &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p>\n\n<p>Remote Online, if the component is supported by SUM but is not yet part of an SPP:<br />\n&nbsp; &nbsp; Download the appropriate SPP<br />\n&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />\n&nbsp; &nbsp; Run SUM<br />\n&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />\n&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />\n&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />\n&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />\n&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />\n&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at: <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p>\n\n<p>Note: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p>\n\n<p>To use HPE Insight Control for vCenter: &nbsp;<br />\n&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />\n&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p>\n\n<p>To update firmware from VMware ESXi operating system on target server: &nbsp;<br />\n&nbsp; &nbsp; Enable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Login as root. (You must be root in order to apply the update) &nbsp;<br />\n&nbsp; &nbsp; Place the Smart Component in a temporary directory<br />\n&nbsp; &nbsp; Check if the nmst module is loaded already: vmkload_mod -l | grep nmst<br />\n&nbsp; &nbsp; If module is not loaded, use the command to load the module: vmkload_mod nmst<br />\n&nbsp; &nbsp; From the same directory, execute the Smart Component. For example: unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe<br />\n&nbsp; &nbsp; Follow the directions given by the Smart Component.<br />\n&nbsp; &nbsp; Logout.<br />\n&nbsp; &nbsp; Disable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Reboot your system, if required, for the firmware update to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (ESXi 6.7) for HPE Mellanox VPI (Ethernet and Infiniband mode) devices on VMware ESXi 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-10-16T19:30:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5000:</strong><br />\n&nbsp;&nbsp; &nbsp;764282-B21<br />\n&nbsp;&nbsp; &nbsp;764286-B21&nbsp;&nbsp;</p>\n\n<p><strong>Firmware for the following devices are updated to 2.42.5056:</strong><br />\n&nbsp;&nbsp; &nbsp;764283-B21<br />\n&nbsp;&nbsp;&nbsp;&nbsp;764284-B21</p>\n\n<p><strong>Firmware for the following device&nbsp;is&nbsp;updated to 2.42.5700:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;764285-B21</p>\n\n<p><strong>New features in firmware version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>Added support for the following features.\n\t<ul>\n\t\t<li>new TLV: CX3_GLOBAL_CONF to enable/disable timestamp on incoming packets through mlxconfig configuration.</li>\n\t\t<li>User MAC configuration.</li>\n\t\t<li>Automatically collecting mstdump before driver reset.</li>\n\t\t<li>A&nbsp;mechanism to detect DEAD_IRISC (plastic) from TPT (iron) and raise an assert.</li>\n\t\t<li>A new field is added to &quot;set port&quot; command which notifies the firmware what is the user_mtu size.</li>\n\t</ul>\n\t</li>\n\t<li>Improved the debug ability for command timeout cases.</li>\n</ul>\n\n<p><strong>New features and changes&nbsp;in firmware version 2.42.5700.</strong></p>\n\n<ul>\n\t<li>Modified the mlx_cmd_get_mlx_link_status command return value to return &quot;Link Type = Ethernet&quot; in Ethernet adapter cards.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Fixes in version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>PortRcvPkts counter was prevented from being cleared after&nbsp;resetting it.</li>\n\t<li>The system&nbsp;Timed Out on the configuration cycle of&nbsp;the Virtual Functions (VFs) when more than 10 Virtual Functions&nbsp;performed FLR and the completion Time Out&nbsp;value was configured to a range of less than&nbsp;16 msec.</li>\n\t<li>The server hangs and results in NMI when running&nbsp;&ldquo;mlxfwtop &ndash;d mt4103_pci_cr0&rdquo; while&nbsp;restarting the driver in parallel (from a different&nbsp;thread). In this case, the downstream&nbsp;bridge over the device reported completion&nbsp;timeout error.</li>\n\t<li>In flow_steering,&nbsp;BMC could not receive a ping over&nbsp;IPV6 after running bmc_reboot.</li>\n\t<li>While closing the&nbsp;HCA, the RX packet caused bad access to&nbsp;resources that did not exist, and consequently caused the QPCGW or the irisc to get stuck.</li>\n\t<li>The master SMLID&nbsp;and the LID was either 0 or&nbsp;0xFFFF when the port was neither active nor&nbsp;armed.</li>\n\t<li>ibdump could not capture&nbsp;all MADs packets.</li>\n\t<li>link did not&nbsp;go up after reboot.</li>\n\t<li>Fixed a rare issue that cause the PCIe&nbsp;configuration cycle that arrived during the&nbsp;time of sw_reset to generate 2 completions.</li>\n\t<li>Network Controller Sideband Interface (NC-SI) did not&nbsp;work when adding the disable_static_steering_ini field in the ini file, due to&nbsp;memory allocation issue for this field in the&nbsp;scratchpad.</li>\n</ul>\n\n<p><strong>Fixes in version 2.42.5056:</strong></p>\n\n<ul>\n\t<li>Fixed an issue that resulted in reading from invalid I/O address on handover from UEFI boot to OS boot, when a port was configured as InfiniBand on a VPI adapter device.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5000:</strong><br />\n&nbsp;&nbsp; &nbsp;764282-B21<br />\n&nbsp;&nbsp; &nbsp;764286-B21&nbsp;&nbsp;</p>\n\n<p><strong>Firmware for the following devices are updated to 2.42.5056:</strong><br />\n&nbsp;&nbsp; &nbsp;764283-B21<br />\n&nbsp;&nbsp;&nbsp;&nbsp;764284-B21</p>\n\n<p><strong>Firmware for the following device&nbsp;is&nbsp;updated to 2.42.5700:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;764285-B21</p>\n\n<p><strong>New features in firmware version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>Added support for the following features.\n\t<ul>\n\t\t<li>new TLV: CX3_GLOBAL_CONF to enable/disable timestamp on incoming packets through mlxconfig configuration.</li>\n\t\t<li>User MAC configuration.</li>\n\t\t<li>Automatically collecting mstdump before driver reset.</li>\n\t\t<li>A&nbsp;mechanism to detect DEAD_IRISC (plastic) from TPT (iron) and raise an assert.</li>\n\t\t<li>A new field is added to &quot;set port&quot; command which notifies the firmware what is the user_mtu size.</li>\n\t</ul>\n\t</li>\n\t<li>Improved the debug ability for command timeout cases.</li>\n</ul>\n\n<p><strong>New features and changes&nbsp;in firmware version 2.42.5700.</strong></p>\n\n<ul>\n\t<li>Modified the mlx_cmd_get_mlx_link_status command return value to return &quot;Link Type = Ethernet&quot; in Ethernet adapter cards.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Fixes in version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>PortRcvPkts counter was prevented from being cleared after&nbsp;resetting it.</li>\n\t<li>The system&nbsp;Timed Out on the configuration cycle of&nbsp;the Virtual Functions (VFs) when more than 10 Virtual Functions&nbsp;performed FLR and the completion Time Out&nbsp;value was configured to a range of less than&nbsp;16 msec.</li>\n\t<li>The server hangs and results in NMI when running&nbsp;&ldquo;mlxfwtop &ndash;d mt4103_pci_cr0&rdquo; while&nbsp;restarting the driver in parallel (from a different&nbsp;thread). In this case, the downstream&nbsp;bridge over the device reported completion&nbsp;timeout error.</li>\n\t<li>In flow_steering,&nbsp;BMC could not receive a ping over&nbsp;IPV6 after running bmc_reboot.</li>\n\t<li>While closing the&nbsp;HCA, the RX packet caused bad access to&nbsp;resources that did not exist, and consequently caused the QPCGW or the irisc to get stuck.</li>\n\t<li>The master SMLID&nbsp;and the LID was either 0 or&nbsp;0xFFFF when the port was neither active nor&nbsp;armed.</li>\n\t<li>ibdump could not capture&nbsp;all MADs packets.</li>\n\t<li>link did not&nbsp;go up after reboot.</li>\n\t<li>Fixed a rare issue that cause the PCIe&nbsp;configuration cycle that arrived during the&nbsp;time of sw_reset to generate 2 completions.</li>\n\t<li>Network Controller Sideband Interface (NC-SI) did not&nbsp;work when adding the disable_static_steering_ini field in the ini file, due to&nbsp;memory allocation issue for this field in the&nbsp;scratchpad.</li>\n</ul>\n\n<p><strong>Fixes in version 2.42.5056:</strong></p>\n\n<ul>\n\t<li>Fixed an issue that resulted in reading from invalid I/O address on handover from UEFI boot to OS boot, when a port was configured as InfiniBand on a VPI adapter device.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_VPI","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWSRQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757535251","Version":"HPG4"},{"DeviceName":"VK000480GWSRR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757535252","Version":"HPG4"},{"DeviceName":"VK000960GWSRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757535254","Version":"HPG4"},{"DeviceName":"VK001920GWSRU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757535255","Version":"HPG4"},{"DeviceName":"VK003840GWSRV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304757535256","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000240GWSRQ, VK000480GWSRR, VK000960GWSRT, VK001920GWSRU and VK003840GWSRV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK000240GWSRQ, VK000480GWSRR, VK000960GWSRT, VK001920GWSRU and VK003840GWSRV Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"19124597","datemodified":"2021-08-27T12:18:04","file_list":["/CP048434_BUILD_2.data","/CP048434.vmexe","/CP048434.vmexe64","/CP048434.vmfile","/CP048434_VMw.zip","/CP048434.xml","/payload.json","/CP048434_VMw.zip/index.xml","/CP048434_VMw.zip/vendor-index.xml","/CP048434_VMw.zip/metadata.zip","/CP048434_VMw.zip/vib20/CP048434/HPE_bootbank_CP048434_HPG4.2-7.0.0.15843807.vib","/CP048434_VMw.zip/metadata.zip/vendor-index.xml","/CP048434_VMw.zip/metadata.zip/vmware.xml","/CP048434_VMw.zip/metadata.zip/vibs/CP048434-2627125466042958914.xml","/CP048434_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048434_HPG4.2-7.0.0.15843807.xml"],"md5sum":"c1d05596b208a6be37d9fe7c493aa0a6","name":"CP048434.zip","release":"2021-08-27T12:12:42","revision":"0","sha1sum":"3e8d75d015a5058202fc9bf9215d0c7224d82e35","size":"18MB","target_guids":["562340a5-304b-3030-3234-304757535251","562340a5-304b-3030-3438-304757535252","562340a5-304b-3030-3936-304757535254","562340a5-304b-3130-3932-304757535255","562340a5-304b-3330-3834-304757535256"],"type_of_change":"1","version":"HPG4","vib_list":[{"name":"CP048434","version":"HPG4.2-7.0.0.15843807"}]}],"id":{"product":"fee6e5ef12074571bae786cf87c0e11d","version":"06e501a247cc49c3a415bec89f443a01"},"installation":{"command":"CP043495.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします。</li>\n\t<li>CPXXXXXX.vmexe(ESXi 6.7 &以前のバージョン)およびCPXXXXXX.vmexe64(ESXi 7.0)は、次のコマンドを使用して実行可能です:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod x CPXXXXXX.vmexe    または    chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPXXXXXX.vmexe(または)./CPXXXXXX.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK000240GWSRQ, VK000480GWSRR, VK000960GWSRT, VK001920GWSRU, VK003840GWSRV  Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VK000240GWSRQ、VK000480GWSRR、VK000960GWSRT、VK001920GWSRU、およびVK003840GWSRVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VK003840GWSRV","target_guid":"562340a5-304b-3330-3834-304757535256","type":"sata"},{"id":"VK001920GWSRU","target_guid":"562340a5-304b-3130-3932-304757535255","type":"sata"},{"id":"VK000960GWSRT","target_guid":"562340a5-304b-3030-3936-304757535254","type":"sata"},{"id":"VK000480GWSRR","target_guid":"562340a5-304b-3030-3438-304757535252","type":"sata"},{"id":"VK000240GWSRQ","target_guid":"562340a5-304b-3030-3234-304757535251","type":"sata"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-10T10:02:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK001920GWSRU","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GWSRV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWSRQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWSRT","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWSRR","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800213","languages":[{"lang":"fr","x_late":"Logiciel - Lights-Out Management"},{"lang":"en","x_late":"Software - Lights-Out Management"},{"lang":"cn","x_late":"软件 - Lights-Out Management"},{"lang":"tw","x_late":"軟體 ─ Lights-Out 管理"},{"lang":"de","x_late":"Software - LOM (Lights-Out Management)"},{"lang":"ko","x_late":"소프트웨어 - Lights-Out 관리"},{"lang":"ja","x_late":"ソフトウェア - Lights-Outマネジメント"},{"lang":"es","x_late":"Software - Administración de apagado eléctrico"}]}],"description":[{"lang":"en","x_late":"This smart component contains the HPE Lights-Out Online Configuration Utility which is a command line utility used to configure ProLiant Integrated Lights-Out processor (iLO) from within the operating system without requiring a reboot of the server."},{"lang":"ja","x_late":"このSmartコンポーネントには、サーバーを再起動しないでオペレーティングシステムからProLiant Integrated Lights-Out（iLO）プロセッサーを設定するために使用するコマンドラインユーティリティである、HPE Lights-Outオンライン設定ユーティリティが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]}],"documentation":[],"files":[{"bytes":"1263224","datemodified":"2020-12-03T03:18:33","file_list":["cp046381.xml","cpqsetup.exe","hponcfg.dll","hponcfg.msi"],"md5sum":"ce511beec2b9357e9e9a1352493db989","name":"cp046381.exe","release":"2020-12-03T03:09:06","revision":"0","sha1sum":"b598eeb9cc87aac2a63b84171c0ff20e04b75d12","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec6b3a6f74"],"type_of_change":"0","version":"5.5.0.0"}],"id":{"product":"C9113","version":"6c968b1872524d75a306b957bc4aa2e6"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":28,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Uninstall any older version of HPONCFG before installing this version of HPONCFG.</p>\n\n<p>Place Component to a directory in a temporary directory on your hard drive. Double-click it to run.</p>\n\n<p>Click on the install button to install the utlility on the server. This does not require a reboot.</p>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n\n<p>The utility will be installed in the program files under the directory HewlettPackardEnterprise\\HPONCFG\\</p>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n\n<p>A shortcut for the graphical interface of the utility will be provided in &quot;Start Menu &gt; Programs &gt; HPE System Tools &gt; HPE Lights-Out Online Configuration Utility&quot;.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Lights-Out Online Configuration Utility for Windows x64 Editions"},{"lang":"ja","x_late":"HPE Lights-Out オンライン構成ユーティリティfor Windows x64 Editions"}],"prerequisites":{"required_diskspace":{"size_kb":"160"},"supported_devices":[{"dev":"B204","subdev":"B206","subven":"0E11","target_guid":"a6b1a447-382a-5a4f-0e11-b2040e11b206","type":"pci","ven":"0E11"},{"dev":"3306","subdev":"330e","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3306103c330e","type":"pci","ven":"103c"},{"dev":"3307","subdev":"330e","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3307103c330e","type":"pci","ven":"103c"},{"dev":"3308","subdev":"330e","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3308103c330e","type":"pci","ven":"103c"},{"dev":"3300","subdev":"330e","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3300103c330e","type":"pci","ven":"103c"},{"dev":"3301","subdev":"330e","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3301103c330e","type":"pci","ven":"103c"},{"dev":"3302","subdev":"330e","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3302103c330e","type":"pci","ven":"103c"},{"dev":"3306","subdev":"3309","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3306103c3309","type":"pci","ven":"103c"},{"dev":"3307","subdev":"3309","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3307103c3309","type":"pci","ven":"103c"},{"dev":"3308","subdev":"3309","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3308103c3309","type":"pci","ven":"103c"},{"dev":"3300","subdev":"3309","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3300103c3309","type":"pci","ven":"103c"},{"dev":"3301","subdev":"3309","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3301103c3309","type":"pci","ven":"103c"},{"dev":"3302","subdev":"3309","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3302103c3309","type":"pci","ven":"103c"},{"dev":"3307","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3307159000e4","type":"pci","ven":"103C"},{"id":"5219994","target_guid":"","type":"other"},{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3306103c3381","type":"pci","ven":"103C"},{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3307103c3381","type":"pci","ven":"103C"},{"dev":"3308","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3308103c3381","type":"pci","ven":"103C"},{"dev":"3300","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3300103c3381","type":"pci","ven":"103C"},{"dev":"3301","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3301103c3381","type":"pci","ven":"103C"},{"dev":"3302","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3302103c3381","type":"pci","ven":"103C"},{"id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","target_guid":"","type":"other"},{"dev":"3306","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3306159000e4","type":"pci","ven":"103C"},{"dev":"3307","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"027F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-33061590027f","type":"pci","ven":"103C"},{"dev":"3307","subdev":"027F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-33071590027f","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"Microsoft Windows Server 2008 x64","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"edition":"fndtn","major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2 Foundation Edition","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"0","name":"Microsoft Windows Storage Server 2008 x64 Editions","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-03T03:04:07","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This version of utility specifically contains changes related to updating legacy HP branding and brand&nbsp;<br />\nreferences from prior to the separation of Hewlett-Packard Company to current HPE branding and&nbsp;<br />\nreferences. If you make use of this version existing scripts may break. You may have to update scripts<br />\nto refer to new version.</p>\n","latest_fixes_x_late":"<p>This version does not contain any defect fixes.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fixed an issue were HPONCFG Windows Smart Component was not installing when SW RAID configuration enabled in RBSU.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"Carbondale14","value":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4520 Gen9 Chassis</p>\n"},{"key":"Carbondale14","value":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>\n"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I25","value":"HP ProLiant BL680c G7 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"P78","value":"HP ProLiant ML310e Gen8 v2 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I25","value":"HP ProLiant BL620c G7 Server"},{"key":"U24","value":"HPE ProLiant XL2x260w Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"P65","value":"HP ProLiant DL580 G7 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"","value":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 SE Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"","value":"HP StorageWorks 600 All-in-One Storage System"},{"key":"A45","value":"HPE XL925g Quad Gen10 Plus EPYC Server"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"A31","value":"HP ProLiant SL4545 G7 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"P83","value":"HP ProLiant SL210t Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P68","value":"HP ProLiant DL360 G7 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P88","value":"HP ProLiant ML10 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"A20","value":"HP ProLiant BL685c G7 Server"},{"key":"P67","value":"HP ProLiant DL380 G7 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"","value":"HP StorageWorks 1200 All-in-One Storage System"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"W04","value":"HP ProLiant DL320s Storage Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"P66","value":"HP ProLiant DL980 G7 Server"},{"key":"P94","value":"HP ProLiant XL220a Gen8 v2 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U14","value":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"key":"U51","value":"HPE ProLiant XL920g Gen10 Plus Server"},{"key":"A19","value":"HP ProLiant BL465c G7 Server"},{"key":"A18","value":"HP ProLiant DL385 G7 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"","value":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"I15","value":"HP ProLiant BL460c Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"J06","value":"HP ProLiant MicroServer Gen8"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"A16","value":"HP ProLiant DL585 G7 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I27","value":"HP ProLiant BL460c G7 Server"},{"key":"I28","value":"HP ProLiant BL490c G7 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"P64","value":"HP ProLiant DL360 G6 Server"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"},{"key":"I29","value":"HP ProLiant BL2x220c G7 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"hponcfg.exe","sw_key_expectedpath":"%ProgramFiles%\\Hewlett Packard Enterprise\\HPONCFG"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900217","languages":[{"lang":"fr","x_late":"Micrologiciel - Infrastructure Blade"},{"lang":"en","x_late":"Firmware - Blade Infrastructure"},{"lang":"cn","x_late":"固件 - 刀片式架构"},{"lang":"tw","x_late":"韌體 ─ 刀鋒型基礎架構"},{"lang":"de","x_late":"Firmware - Blade-Infrastruktur"},{"lang":"ko","x_late":"펌웨어 - 블레이드 인프라"},{"lang":"it","x_late":"Firmware - Infrastruttura Blade"},{"lang":"ja","x_late":"ファームウェア - ブレード インフラストラクチャ"},{"lang":"es","x_late":"Firmware - Infraestructura Blade"}]}],"description":[{"lang":"en","x_late":"This Smart Component contains the firmware image for the HP 6Gb SAS BL Switch.  After downloading the component and extracting the firmware image to a directory, access the Virtual SAS Manager's GUI or CLI interface to flash the firmware."},{"lang":"ja","x_late":"このSmart Componentには、HP 6Gb SAS BLスイッチのファームウェア イメージが含まれています。  コンポーネントをダウンロードしてディレクトリにファームウェア イメージを展開したら、Virtual SAS ManagerのGUIかCLIインターフェイスにアクセスしてファームウェアをフラッシュします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online HP 6Gb SAS BL Switch Firmware Smart Component for Linux (x86/x64)<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;4.3.6.0 (B)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 4.2.2.0<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 4.2.1.0<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; The devices listed below require minimum FW deliverables with HP Storage Manager version 4.1.1.0:<br />\n<br />\n<strong>Device, Minimum Recommended Version</strong></p>\n\n<ul>\n\t<li>HP D3600/D3700/D3610/D3710 Disk Enclosure, 3.64</li>\n\t<li>HP D2600/D2700 Disk Enclosure, 0150</li>\n\t<li>HP 600 Modular Disk System, 3.68</li>\n\t<li>HP D6000 Disk Enclosure, 2.98</li>\n\t<li>HP D6020 Disk Enclosure, 2.53</li>\n</ul>\n\n<p><strong>Enhancements/New Features for FW version 4.3.6.0 (B):</strong><strong>&nbsp;</strong></p>\n\n<ul>\n\t<li>Added support for SUSE Linux Enterprise Server 15 OS</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p style=\"margin-left:40px\">None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; None<br />\n&nbsp;</p>\n"}],"files":[{"bytes":"34000365","datemodified":"2018-09-26T20:07:41","file_list":["./usr/lib/i586-linux-gnu/firmware-solex6gb-solex-4.3.6.0-2.1","./usr/lib/i586-linux-gnu/firmware-solex6gb-solex-4.3.6.0-2.1/.cpq_package.inc","./usr/lib/i586-linux-gnu/firmware-solex6gb-solex-4.3.6.0-2.1/.setup","./usr/lib/i586-linux-gnu/firmware-solex6gb-solex-4.3.6.0-2.1/CP037681.xml","./usr/lib/i586-linux-gnu/firmware-solex6gb-solex-4.3.6.0-2.1/cp_data.xml","./usr/lib/i586-linux-gnu/firmware-solex6gb-solex-4.3.6.0-2.1/hpsetup","./usr/lib/i586-linux-gnu/firmware-solex6gb-solex-4.3.6.0-2.1/setup","./usr/lib/i586-linux-gnu/firmware-solex6gb-solex-4.3.6.0-2.1/vsm_release_4.3.6.0.img","./usr/lib/i586-linux-gnu/hp-scexe-compat","./usr/lib/i586-linux-gnu/hp-scexe-compat/CP037681.scexe","./usr/lib/i586-linux-gnu/scexe-compat","./usr/lib/i586-linux-gnu/scexe-compat/CP037681.scexe"],"md5sum":"301d93fa1148fd24956bbc22a2fe057c","name":"firmware-solex6gb-solex-4.3.6.0-2.1.i586.rpm","release":"2018-09-27T01:00:04","revision":"0","sha1sum":"be24adb881bd827d01e426b4302589725d1bdd4a","size":"32MB","target_guids":[],"type_of_change":"0","version":"4.3.6.0"}],"id":{"product":"a2a4da3071f14ea0b229b51686cf6bd9","version":"0ed32969accd4e30809f5ca59302841a"},"installation":{"command":"Entry.bsh","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Installation Instructions:</strong></p>\n\n<p><br />\n<strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;rpm -ivh &lt;rpm_filename&gt;.&nbsp;&nbsp;This extracts the contents of the rpm to the &#39;/usr/lib/<strong>x86_64-linux-gnu</strong>&#39; location</li>\n\t<li>To uninstall the rpm, run the command: rpm -e &lt;rpm_package_name&gt;, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><strong><em>Updating firmware without installing the rpm</em></strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;&nbsp;</em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system.&nbsp;</p>\n\n<p>&nbsp;</p>\n\n<p><strong><strong>HP recommends for remote deployment of this package that you obtain the most recent version of the&nbsp;</strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a><strong>(SPP) and follow these steps:</strong></strong></p>\n\n<ul style=\"list-style-type: square;\">\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>..</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li>\n\t<li>Run launch_sum.sh script which is found in the root of the ISO.</li>\n\t<li>Follow the GUI instructions to install the firmware on the remote host.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>インストール手順：</strong></p>\n\n<p><br />\n<strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>コマンドpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします：  これは、'/usr/lib/<strong>x86_64-linux-gnu</strong>' の場所へrpm の内容を解凍します。</li>\n\t<li>rpmをアンインストールするには、次のコマンドを実行します。<rpm_package_name> これは.rpm'拡張子なしのrpmファイル名です。</li>\n</ul>\n\n<p><strong><em>rpmのインストールなしでのファームウェアのアップデート</em></strong></p>\n\n<ul>\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id  </em>これは、現在のディレクトリの‘usr’フォルダーへrpmの内容を抽出します。</li>\n</ul>\n\n<p><strong><em>追加情報:</em></strong></p>\n\n<p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を解凍するだけです。 </p>\n\n<p> </p>\n\n<p><strong><strong>このパッケージのリモートデプロイメントには、最新のバージョンの</strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant</a><strong>（SPP）を入手して、以下の手順を実行することをおすすめします。</strong></strong></p>\n\n<ul style=\"list-style-type: square;\">\n\t<li><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/SPP20xxxxx/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにあるlaunch_sum.shスクリプトを実行します。</li>\n\t<li>GUIの指示に従ってリモートホストにファームウェアをインストールします。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HP 6Gb SAS BL Switch Firmware Smart Component for Linux (x86/x64)"},{"lang":"ja","x_late":"オンラインHP 6Gb SAS BLスイッチファームウェア Smart Component for Linux (x86/x64)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"id":"HP6GSASBLSWH","target_guid":"","type":"sas"}],"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-10-24T18:13:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Initial drop for Snap3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for SUSE Linux Enterprise Server 15 OS</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"solex","sw_key_expectedpath":"firmware:solex6Gb"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 adapter cards."},{"lang":"ja","x_late":"このRPMには、サポートされているHPE Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 アダプターカード用のHPEによるテストと承認済みのLinuxベースMellanox RoCE (RDMA over Converged Ethernet)ドライバーが含まれます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1562833","datemodified":"2021-07-21T07:00:03","file_list":["./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/compat","./lib/modules/4.12.14-120-default/updates/compat/mlx_compat.ko","./lib/modules/4.12.14-120-default/updates/drivers","./lib/modules/4.12.14-120-default/updates/drivers/base","./lib/modules/4.12.14-120-default/updates/drivers/base/auxiliary.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/ib_cm.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/ib_core.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/ib_ucm.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/ib_umad.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/iw_cm.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/rdma_cm.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/cxgb3","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/cxgb3/iw_cxgb3.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/cxgb4","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/efa","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/efa/efa.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/hfi1","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/i40iw","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/mlx4","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/mlx5","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/mthca","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/mthca/ib_mthca.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/nes","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/nes/iw_nes.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/ocrdma","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/ocrdma/ocrdma.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/qedr","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/qib","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/qib/ib_qib.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/usnic","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/sw","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/sw/rdmavt","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/sw/rxe","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/ipoib","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/iser","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/isert","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/opa_vnic","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/srp","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/srpt","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/4.12.14-120-default/updates/drivers/net","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlx5","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/4.12.14-120-default/updates/drivers/nvme","./lib/modules/4.12.14-120-default/updates/drivers/nvme/host","./lib/modules/4.12.14-120-default/updates/drivers/nvme/host/nvme-rdma.ko","./lib/modules/4.12.14-120-default/updates/drivers/nvme/target","./lib/modules/4.12.14-120-default/updates/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/4.12.14-120-default/updates/net","./lib/modules/4.12.14-120-default/updates/net/9p","./lib/modules/4.12.14-120-default/updates/net/9p/9pnet_rdma.ko","./lib/modules/4.12.14-120-default/updates/net/rds","./lib/modules/4.12.14-120-default/updates/net/rds/rds_rdma.ko","./lib/modules/4.12.14-120-default/updates/net/sunrpc","./lib/modules/4.12.14-120-default/updates/net/sunrpc/xprtrdma","./lib/modules/4.12.14-120-default/updates/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/4.12.14-120-default/updates/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/4.12.14-120-default/updates/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/mlnx-ofa_kernel-kmp-default/component.xml"],"md5sum":"1d9f4dd107507976d743ff7b7ea82279","name":"mlnx-ofa_kernel-kmp-default-5.4_k4.12.14_120-OFED.5.4.1.0.3.1.sles12sp5.x86_64.rpm","release":"2021-07-21T05:50:09","revision":"0","sha1sum":"92f8199b4220e6c47dd5141a344f1e4e9deba25c","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"5.4"},{"bytes":"1270994","datemodified":"2021-07-21T07:04:24","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/rdma","./etc/rdma/mlx4.conf","./etc/rdma/modules","./etc/rdma/modules/rdma.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/70-persistent-ipoib.rules","./lib/udev/auxdev-sf-netdev-rename","./lib/udev/mlnx_bf_udev","./lib/udev/rules.d/82-net-setup-link.rules","./lib/udev/rules.d/83-mlnx-sf-name.rules","./lib/udev/rules.d/90-ib.rules","./lib/udev/sf-rep-netdev-rename","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/mlnx_bf_configure_ct","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_perf","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/include/mellanox/dpcp.h","./usr/lib/dracut","./usr/lib/dracut/modules.d","./usr/lib/dracut/modules.d/05rdma","./usr/lib/dracut/modules.d/05rdma/module-setup.sh","./usr/lib/mlx4-setup.sh","./usr/lib/modprobe.d","./usr/lib/modprobe.d/libmlx4.conf","./usr/lib/python2.7/site-packages/dcbnetlink.py","./usr/lib/python2.7/site-packages/dcbnetlink.pyc","./usr/lib/python2.7/site-packages/dcbnetlink.pyo","./usr/lib/python2.7/site-packages/genetlink.py","./usr/lib/python2.7/site-packages/genetlink.pyc","./usr/lib/python2.7/site-packages/genetlink.pyo","./usr/lib/python2.7/site-packages/mlnx_tools-5.2.0-py2.7.egg-info","./usr/lib/python2.7/site-packages/netlink.py","./usr/lib/python2.7/site-packages/netlink.pyc","./usr/lib/python2.7/site-packages/netlink.pyo","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/rdma-ndd.service","./usr/lib/systemd/system/vma.service","./usr/lib/udev/rdma_rename","./usr/lib/udev/rules.d","./usr/lib/udev/rules.d/60-rdma-ndd.rules","./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules","./usr/lib/udev/rules.d/75-rdma-description.rules","./usr/lib/udev/rules.d/90-rdma-umad.rules","./usr/lib64/libdpcp.so","./usr/lib64/libdpcp.so.1","./usr/lib64/libdpcp.so.1.1.12","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.35.0","./usr/lib64/libibverbs","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.14.35.0","./usr/lib64/libibverbs/libmlx5-rdmav34.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.19.35.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.3.35.0","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.3.1","./usr/lib64/rsocket","./usr/lib64/rsocket/librspreload.so","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/ibdev2netdev","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/rdma-ndd","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vmad","./usr/share/doc/packages/dpcp","./usr/share/doc/packages/dpcp/README","./usr/share/doc/packages/libibverbs","./usr/share/doc/packages/libibverbs/libibverbs.md","./usr/share/doc/packages/librdmacm","./usr/share/doc/packages/librdmacm/librdmacm.md","./usr/share/doc/packages/libvma-9.3.1","./usr/share/doc/packages/libvma-9.3.1/CHANGES","./usr/share/doc/packages/libvma-9.3.1/README","./usr/share/doc/packages/mlnx-tools","./usr/share/doc/packages/mlnx-tools/ib2ib_setup.txt","./usr/share/doc/packages/rdma-core","./usr/share/doc/packages/rdma-core/COPYING.BSD_FB","./usr/share/doc/packages/rdma-core/COPYING.BSD_MIT","./usr/share/doc/packages/rdma-core/COPYING.GPL2","./usr/share/doc/packages/rdma-core/COPYING.md","./usr/share/doc/packages/rdma-core/README.md","./usr/share/doc/packages/rdma-core/tag_matching.md","./usr/share/doc/packages/rdma-core/udev.md","./usr/share/man/man7/rsocket.7.gz","./usr/share/man/man7/vma.7.gz","./usr/share/man/man8/ib2ib_setup.8.gz","./usr/share/man/man8/rdma-ndd.8.gz","./usr/share/man/man8/vmad.8.gz","./usr/share/mlnx_ofed/mlnx_bf_assign_ct_cores.sh","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml"],"md5sum":"54541aa6713821bf57a6615da8684794","name":"mlnx-ofa_kernel-5.4-OFED.5.4.1.0.3.1.sles12sp5.x86_64.rpm","release":"2021-07-21T05:50:09","revision":"0","sha1sum":"50627e92d019725fcb65a5da6791b93ff3da2eaa","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"5.4"}],"id":{"product":"194ff765dcf14c3183bf0b90a60ddc0c","version":"bccc5df1c2df41e1a55c30c1b77538c2"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"11.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPMs to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-5.4&quot; RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.</p>\n\n<p>To install or upgrade the driver:<br />\nIf using 4.12.14-120-default kernel or any future errata:<br />\n<br />\n<strong># rpm -Uvh&nbsp;mlnx-ofa_kernel-5.4-OFED.5.4.0.5.1.1.sles12sp5.x86_64.rpm mlnx-ofa_kernel-kmp-default-5.4_k4.12.14_120-OFED.5.4.0.5.1.1.sles12sp5.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 Adapters for SUSE LINUX Enterprise Server 12 SP5 (AMD64/EM64T)"},{"lang":"ja","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet)ドライバーfor Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 Adapters for SUSE LINUX Enterprise Server 12 SP5 (AMD64/EM64T) "}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"101f","subdev":"0012","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30012","type":"pci","ven":"15b3"},{"dev":"101f","subdev":"0007","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30007","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"032D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-10171590032d","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T17:11:55","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Changes and new features in HPE Mellanox RoCE driver&nbsp;version 5.2:</strong></p>\n\n<p><strong>For ConnectX-5 Adapters and above:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>CQE compression support for Rx multi-strides packets.</li>\n\t\t<li>Configuring QoS on a single QP or on a group of QPs.</li>\n\t\t<li>Encap/decap hardware offload of IPv4 traffic over MPLS-over-UDP. This can be used in networks with MPLS routers to achieve more efficient routing.</li>\n\t\t<li>Connection tracking rules on VFs to forward traffic from one VF to the other.</li>\n\t\t<li>Offloading sFlow sampling rules.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For ConnectX-5 Adapters and ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>A locking mechanism to enable parallel insertion of rules into the software steering using the mlx5dv_dr API. The parallel insertion improves the insertion rate and takes place when adding Rx and Tx rules via the FDB domain.</li>\n\t\t<li>Option to match mlx5dv_dr API on Geneve tunnel using a dynamic flex parser. The option header consists of class, type, length and data. The parser should be configured using devx command, after which a rule can be created to match on parser ID and data.</li>\n\t\t<li>Geneve tunneling offload, including matching on extension header.</li>\n\t\t<li>Parallel insertion and deletion of offloaded rules using multiple&nbsp;OVS threads.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>[Beta] Modify GTP-U TEID. This support requires flex parser&nbsp;configuration.</li>\n\t\t<li>[Beta] Improved performance of OVS Connection Tracking flows by&nbsp;enabling the merge of the multi-table flow matches and actions into one joint flow.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Dx Adapters and above:</strong></p>\n\n<p>Added support for the following features:</p>\n\n<ul>\n\t<li>Transmitted packet timestamping accuracy can be improved when using a timestamp generated at the port level instead of a timestamp generated upon CQE creation. Tx port time-stamping better reflects the actual time of a packet&#39;s transmission. This feature is disabled by default. The feature can be enabled or disabled using the following command. ethtool --set-priv-flags tx_port_ts on / off.</li>\n\t<li>Offloading tunnel rules when the source interface is VF (in addition to uplink) in the Hypervisor.</li>\n\t<li>Using Mirroring Offload with Connection Tracking.</li>\n\t<li>ASO flow meter using the mlx5dv_dr API, which allows for monitoring the packet rate for specific flows. When a packet hits a flow that is connected to a flow meter, the rate of packets through this meter is evaluated, and the packet is marked with a color copied into one of the C registers, according to the current rate compared to the reference rate.</li>\n\t<li>ASO first hit using the mlx5dv_dr API, which allows for tracking rule hits by packets. When a packet hits a rule with the ASO first hit action, a flag is set indicating this event, and the original value of the flag is copied to one of the C registers.</li>\n\t<li>mlx5dv_dr API support for matching on a new field &quot;gtpu_first_ext_dw_0&quot;. This field enables packet filtering based on the GTP-U first extension header (first dword only). To enable parsing of tunnel GTP-U extension header, run the following command. ./cloud_fw_reset.py FLEX_PARSER_PROFILE_ENABLE=3.</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Lx Adapters and above:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>IPsec full offload support for extended sequence number, replay protection window and lifetime packet limit.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;All HCA&#39;s:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>New query GID API that allows for querying a single GID entry by its port and GID index, or querying for all GID tables of a specific device. This API works over ioctl instead of sysfs, which accelerates the querying process.</li>\n\t\t<li>Performing multi-host firmware reset in order to upgrade the device firmware. Firmware reset loads the new firmware in case it was burnt on the flash and was pending activation, and reload.</li>\n\t\t<li>[Alpha] Firmware live patching in the driver. Live patching updates the firmware without the need to perform firmware reset. However, it can only be applied in scenarios where the difference between the current and new firmware versions are minor, which is decided upon by the firmware itself.</li>\n\t\t<li>devlink tool for performing firmware reset in order to upgrade the device firmware. Firmware reset loads the new firmware in case it was burnt on the flash and was pending activation, and reloads the current firmware image from the flash in case no new firmware was pending. For further information, please refer to the the devlink man page.</li>\n\t\t<li>A resiliency mechanism for the driver to manually poll the command event queue (EQ) in case of a command timeout. In case the resiliency mechanism finds unhandled event queue entry (EQE) due to a lost interrupt, the driver will handle it, after which the command interface returns to a healthy state.</li>\n\t\t<li>Setting a sniffer private flag is deprecated and no longer required. In order to capture offloaded/RoCE traffic, tcpdump can now be run on the RDMA device.</li>\n\t\t<li>Added per-port reporters to devlink health to manage per-port health activities. Users can now access the devlink port reporters by specifying the port index in addition to the device devlink name through the devlink health commands API. This update was first introduced in iproute2 v5.8. As part of this feature, mlx5e Tx and Rx reporters are now redefined as devlink port reporters. For examples, please see devlink-health manpage</li>\n\t\t<li>Optimized memory consumption of memory registration in huge page systems. As an example, in a 2MB huge page system, 600 MB would be saved for 100 GB memory registration.</li>\n\t\t<li>mlx5dv API to modify the configured UDP source port for RoCE packets of a given RC/UC QP when QP is in RTS state.</li>\n\t\t<li>Accelerating Tx datapath by saving PCI bandwidth and CPU utilization. The savings are achieved by aggregating multiple packets into a single WQE. The feature is driven by xmit_more for certain traffic types, such as UDP.</li>\n\t</ul>\n\t</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 5.2:</strong></p>\n\n<ul>\n\t<li>Clearing min_rate on all SR-IOV legacy VFs after setting min_rate to at least one of the VFs did not disable QoS min_rate.</li>\n\t<li>An empty /usr/src/mlnx-ofa_kernel/default is now no longer created.</li>\n\t<li>An issue where installing packages through a repository failed after generation of metapackages using --add-kernel-support. The failure occurred due to excessive and incorrect Obsolete headers in those metapackages.Enabled installation of mlnx-ofa_kernel package to /bin/python3 instead of / usr/bin/python3 on RHEL 8.x systems.</li>\n\t<li>All IPoIB offload packets were wrongly counted as rx_csum_complete. These packets are now identified as rx_csum_unnecessary packets.</li>\n\t<li>mlx5dv_dr_rule_destroy segmentation fault could happen in rare cases with multiple rules on the same matcher with a different number of actions. This could happen after reusing an already deleted rule memory with less actions.</li>\n\t<li>An issue of moving to SwitchDev mode after configuring DSCP (Differentiated Service Code Point).</li>\n\t<li>Global traffic class configuration did not take effect on DC QPs (Dynamically Connected Queue Pairs).</li>\n\t<li>ib_send_bw traffic frequently dropped to zero when RDMA CM was used, because of incorrect&nbsp;min_rnr_timer setting on the responder side. The min_rnr_timer setting is now aligned with the setting in non-RDMA CM cases.</li>\n\t<li>Traffic did not pass over VFs with VST QinQ feature is enabled.</li>\n\t<li>When traffic was sent over Geneve VLAN with Tx VLAN offload enabled and TSO (TCP Segmentation Offload)&nbsp;or Tx csum enabled, traffic could be dropped and not sent to the wire.</li>\n\t<li>An issue that caused the firmware to restart upon installing mlnxofed-dpdk-upstream-libs package manually.</li>\n\t<li>Bad utility paths in rdma-core &quot;dracut&quot; hooks on SLES systems, which used to result in the following errors when running &quot;dracut&quot; with the &quot;--add rdma&quot; option. dracut-install:\n\t<ul>\n\t\t<li>ERROR: installing &lsquo;/usr/libexec/mlx4-setup.sh&rsquo; dracut: /usr/lib/dracut/dracut-install -D /var/tmp/dracut.UdCOSJ/ initramfs /usr/libexec/mlx4-setup.sh dracut-install: ERROR: installing &lsquo;/usr/libexec/rdma-set-sriov-vf&rsquo; dracut: /usr/lib/dracut/dracut-install -D /var/tmp/dracut.UdCOSJ/ initramfs /usr/libexec/rdma-set-sriov-vf</li>\n\t</ul>\n\t</li>\n\t<li>Traffic class value was not updated in DCT when set via sysfs.</li>\n\t<li>A doorbell loss issue on AMD platforms with Secure Memory Encryption (SME).</li>\n\t<li>Registering memory using mlx5dv_devx_umem_reg while forking. Without this fix, applications which use fork() or similar syscalls while using a memory registered with umem_reg could hang due to incorrect physical page mapping. This fix requires setting the IBV_FORK_SAFE environment variable.</li>\n\t<li>When&nbsp;unbinding the device resulted in the following message being printed to the dmesg: &quot;failed to disable DC tracer&quot;</li>\n\t<li>Content of file /sys/class/net//statistics/ multicast might have been out of date and might have displayed values lower than the real values.</li>\n\t<li>ERSPAN (Encapsulated Remote SPAN) protocol was available only when turning off Tx checksum offload.</li>\n\t<li>A udev script issue which caused non-mellanox devices to be renamed.</li>\n\t<li>Missing representor statistics when using ifconfig.</li>\n\t<li>Fixed wrong value of skb mark of received packets on representors.</li>\n\t<li>An issue which caused second port representors to be named as first port representors.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Changes and new features in HPE Mellanox RoCE driver&nbsp;version 5.3:</strong></p>\n\n<p><strong>For ConnectX-5 Adapters and above:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>CQE compression support for Rx multi-strides packets.</li>\n\t\t<li>Configuring QoS on a single QP or on a group of QPs.</li>\n\t\t<li>Encap/decap hardware offload of IPv4 traffic over MPLS-over-UDP. This can be used in networks with MPLS routers to achieve more efficient routing.</li>\n\t\t<li>Connection tracking rules on VFs to forward traffic from one VF to the other.</li>\n\t\t<li>Offloading sFlow sampling rules.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For ConnectX-5 Adapters and ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>A locking mechanism to enable parallel insertion of rules into the software steering using the mlx5dv_dr API. The parallel insertion improves the insertion rate and takes place when adding Rx and Tx rules via the FDB domain.</li>\n\t\t<li>Option to match mlx5dv_dr API on Geneve tunnel using a dynamic flex parser. The option header consists of class, type, length and data. The parser should be configured using devx command, after which a rule can be created to match on parser ID and data.</li>\n\t\t<li>Geneve tunneling offload, including matching on extension header.</li>\n\t\t<li>Parallel insertion and deletion of offloaded rules using multiple&nbsp;OVS threads.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>[Beta] Modify GTP-U TEID. This support requires flex parser&nbsp;configuration.</li>\n\t\t<li>[Beta] Improved performance of OVS Connection Tracking flows by&nbsp;enabling the merge of the multi-table flow matches and actions into one joint flow.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Dx Adapters and above:</strong></p>\n\n<p>Added support for the following features:</p>\n\n<ul>\n\t<li>Transmitted packet timestamping accuracy can be improved when using a timestamp generated at the port level instead of a timestamp generated upon CQE creation. Tx port time-stamping better reflects the actual time of a packet&#39;s transmission. This feature is disabled by default. The feature can be enabled or disabled using the following command. ethtool --set-priv-flags tx_port_ts on / off.</li>\n\t<li>Offloading tunnel rules when the source interface is VF (in addition to uplink) in the Hypervisor.</li>\n\t<li>Using Mirroring Offload with Connection Tracking.</li>\n\t<li>ASO flow meter using the mlx5dv_dr API, which allows for monitoring the packet rate for specific flows. When a packet hits a flow that is connected to a flow meter, the rate of packets through this meter is evaluated, and the packet is marked with a color copied into one of the C registers, according to the current rate compared to the reference rate.</li>\n\t<li>ASO first hit using the mlx5dv_dr API, which allows for tracking rule hits by packets. When a packet hits a rule with the ASO first hit action, a flag is set indicating this event, and the original value of the flag is copied to one of the C registers.</li>\n\t<li>mlx5dv_dr API support for matching on a new field &quot;gtpu_first_ext_dw_0&quot;. This field enables packet filtering based on the GTP-U first extension header (first dword only). To enable parsing of tunnel GTP-U extension header, run the following command. ./cloud_fw_reset.py FLEX_PARSER_PROFILE_ENABLE=3.</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Lx Adapters and above:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>IPsec full offload support for extended sequence number, replay protection window and lifetime packet limit.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;All HCA&#39;s:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>New query GID API that allows for querying a single GID entry by its port and GID index, or querying for all GID tables of a specific device. This API works over ioctl instead of sysfs, which accelerates the querying process.</li>\n\t\t<li>Performing multi-host firmware reset in order to upgrade the device firmware. Firmware reset loads the new firmware in case it was burnt on the flash and was pending activation, and reload.</li>\n\t\t<li>[Alpha] Firmware live patching in the driver. Live patching updates the firmware without the need to perform firmware reset. However, it can only be applied in scenarios where the difference between the current and new firmware versions are minor, which is decided upon by the firmware itself.</li>\n\t\t<li>devlink tool for performing firmware reset in order to upgrade the device firmware. Firmware reset loads the new firmware in case it was burnt on the flash and was pending activation, and reloads the current firmware image from the flash in case no new firmware was pending. For further information, please refer to the the devlink man page.</li>\n\t\t<li>A resiliency mechanism for the driver to manually poll the command event queue (EQ) in case of a command timeout. In case the resiliency mechanism finds unhandled event queue entry (EQE) due to a lost interrupt, the driver will handle it, after which the command interface returns to a healthy state.</li>\n\t\t<li>Setting a sniffer private flag is deprecated and no longer required. In order to capture offloaded/RoCE traffic, tcpdump can now be run on the RDMA device.</li>\n\t\t<li>Added per-port reporters to devlink health to manage per-port health activities. Users can now access the devlink port reporters by specifying the port index in addition to the device devlink name through the devlink health commands API. This update was first introduced in iproute2 v5.8. As part of this feature, mlx5e Tx and Rx reporters are now redefined as devlink port reporters. For examples, please see devlink-health manpage</li>\n\t\t<li>Optimized memory consumption of memory registration in huge page systems. As an example, in a 2MB huge page system, 600 MB would be saved for 100 GB memory registration.</li>\n\t\t<li>mlx5dv API to modify the configured UDP source port for RoCE packets of a given RC/UC QP when QP is in RTS state.</li>\n\t\t<li>Accelerating Tx datapath by saving PCI bandwidth and CPU utilization. The savings are achieved by aggregating multiple packets into a single WQE. The feature is driven by xmit_more for certain traffic types, such as UDP.</li>\n\t</ul>\n\t</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 5.3:</strong></p>\n\n<ul>\n\t<li>Clearing min_rate on all SR-IOV legacy VFs after setting min_rate to at least one of the VFs did not disable QoS min_rate.</li>\n\t<li>An empty /usr/src/mlnx-ofa_kernel/default is now no longer created.</li>\n\t<li>An issue where installing packages through a repository failed after generation of metapackages using --add-kernel-support. The failure occurred due to excessive and incorrect Obsolete headers in those metapackages.Enabled installation of mlnx-ofa_kernel package to /bin/python3 instead of / usr/bin/python3 on RHEL 8.x systems.</li>\n\t<li>All IPoIB offload packets were wrongly counted as rx_csum_complete. These packets are now identified as rx_csum_unnecessary packets.</li>\n\t<li>mlx5dv_dr_rule_destroy segmentation fault could happen in rare cases with multiple rules on the same matcher with a different number of actions. This could happen after reusing an already deleted rule memory with less actions.</li>\n\t<li>An issue of moving to SwitchDev mode after configuring DSCP (Differentiated Service Code Point).</li>\n\t<li>Global traffic class configuration did not take effect on DC QPs (Dynamically Connected Queue Pairs).</li>\n\t<li>ib_send_bw traffic frequently dropped to zero when RDMA CM was used, because of incorrect&nbsp;min_rnr_timer setting on the responder side. The min_rnr_timer setting is now aligned with the setting in non-RDMA CM cases.</li>\n\t<li>Traffic did not pass over VFs with VST QinQ feature is enabled.</li>\n\t<li>When traffic was sent over Geneve VLAN with Tx VLAN offload enabled and TSO (TCP Segmentation Offload)&nbsp;or Tx csum enabled, traffic could be dropped and not sent to the wire.</li>\n\t<li>An issue that caused the firmware to restart upon installing mlnxofed-dpdk-upstream-libs package manually.</li>\n\t<li>Bad utility paths in rdma-core &quot;dracut&quot; hooks on SLES systems, which used to result in the following errors when running &quot;dracut&quot; with the &quot;--add rdma&quot; option. dracut-install:\n\t<ul>\n\t\t<li>ERROR: installing &lsquo;/usr/libexec/mlx4-setup.sh&rsquo; dracut: /usr/lib/dracut/dracut-install -D /var/tmp/dracut.UdCOSJ/ initramfs /usr/libexec/mlx4-setup.sh dracut-install: ERROR: installing &lsquo;/usr/libexec/rdma-set-sriov-vf&rsquo; dracut: /usr/lib/dracut/dracut-install -D /var/tmp/dracut.UdCOSJ/ initramfs /usr/libexec/rdma-set-sriov-vf</li>\n\t</ul>\n\t</li>\n\t<li>Traffic class value was not updated in DCT when set via sysfs.</li>\n\t<li>A doorbell loss issue on AMD platforms with Secure Memory Encryption (SME).</li>\n\t<li>Registering memory using mlx5dv_devx_umem_reg while forking. Without this fix, applications which use fork() or similar syscalls while using a memory registered with umem_reg could hang due to incorrect physical page mapping. This fix requires setting the IBV_FORK_SAFE environment variable.</li>\n\t<li>When&nbsp;unbinding the device resulted in the following message being printed to the dmesg: &quot;failed to disable DC tracer&quot;</li>\n\t<li>Content of file /sys/class/net//statistics/ multicast might have been out of date and might have displayed values lower than the real values.</li>\n\t<li>ERSPAN (Encapsulated Remote SPAN) protocol was available only when turning off Tx checksum offload.</li>\n\t<li>A udev script issue which caused non-mellanox devices to be renamed.</li>\n\t<li>Missing representor statistics when using ifconfig.</li>\n\t<li>Fixed wrong value of skb mark of received packets on representors.</li>\n\t<li>An issue which caused second port representors to be named as first port representors.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000JVYZD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPESD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a56595a44","Version":"HPD4"},{"DeviceName":"MB4000JVYZC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPESD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a56595a43","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models:MB6000JVYZD and MB4000JVYZC"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、ドライブモデル：MB6000JVYZDおよびMB4000JVYZCのファームウェアを提供します。"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB6000JVYZD and MB4000JVYZC Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:&nbsp;</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5565082","datemodified":"2021-07-23T07:47:04","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-e800e8d3b9-HPD4-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-e800e8d3b9-HPD4-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-e800e8d3b9-HPD4-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e800e8d3b9-HPD4-6.1/CP048173.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-e800e8d3b9-HPD4-6.1/SMBPESD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-e800e8d3b9-HPD4-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e800e8d3b9-HPD4-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-e800e8d3b9-HPD4-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-e800e8d3b9-HPD4-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048173.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048173.scexe"],"md5sum":"f392fcb737a3c664ce3a0b45a5b4a1d0","name":"firmware-hdd-e800e8d3b9-HPD4-6.1.x86_64.rpm","release":"2021-07-23T07:34:06","revision":"0","sha1sum":"f76a9a653857e49d5a6d65565940ba725e85ece0","size":"5MB","target_guids":["002340a5-4d00-3642-3030-304a56595a44","002340a5-4d00-3442-3030-304a56595a43"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"f433cea5bd0849d286e6c1b1e45a60d4","version":"830d25e99e0c450f93f02ebd5ce8a635"},"installation":{"command":"CP040325.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64)  - MB6000JVYZD and MB4000JVYZC Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB6000JVYZDおよびMB4000JVYZCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB4000JVYZC","target_guid":"002340a5-4d00-3442-3030-304a56595a43","type":"sas"},{"id":"MB6000JVYZD","target_guid":"002340a5-4d00-3642-3030-304a56595a44","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T20:01:49","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JVYZC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB6000JVYZD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900374","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the boot BIOS and firmware of QLogic Fibre Channel host bus adapters."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"11723085","datemodified":"2021-08-25T12:35:02","file_list":["/CP048724_BUILD_2.data","/CP048724.vmexe","/CP048724.vmexe64","/CP048724.vmfile","/CP048724_VMw.zip","/CP048724.xml","/payload.json","/CP048724_VMw.zip/index.xml","/CP048724_VMw.zip/vendor-index.xml","/CP048724_VMw.zip/metadata.zip","/CP048724_VMw.zip/vib20/CP048724/HPE_bootbank_CP048724_2021.10.01.2-6.5.0.4240417.vib","/CP048724_VMw.zip/metadata.zip/vendor-index.xml","/CP048724_VMw.zip/metadata.zip/vmware.xml","/CP048724_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048724_2021.10.01.2-6.5.0.4240417.xml","/CP048724_VMw.zip/metadata.zip/vibs/CP048724--1463057936169552399.xml"],"md5sum":"233e6c9a8af58364d1202f659743db5e","name":"CP048724.zip","release":"2021-08-25T12:18:11","revision":"0","sha1sum":"57a66a7695f263485e1038b7fdf5acf3ad3f901e","size":"11MB","target_guids":[],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"CP048724","version":"2021.10.01.2-6.5.0.4240417"}]}],"id":{"product":"d34f1211054f4033a0d322ff081a19c7","version":"1438bf00b52746ed959fe473ef790f5f"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated if the ESXi host is Gen9 Server or Enter the IP or DNS address of the iLO of the ESXi host if the Sever is Gen10 and above</li>\n\t<li>Enter the ESXi host/iLO credentials (root or administrator username and password) based on Gen9/Gen10 and above</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for QLogic Fibre Channel Host Bus Adapters for VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-18T06:47:35","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\" dir=\"LTR\" style=\"width:935px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Speed</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">MBI</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Firmware</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">UEFI</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Boot Bios</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE 81Q 8Gb PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.82.00</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8.08.207</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.00</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.56</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE 82Q 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.82.00</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8.08.207</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.00</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.56</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE 84Q 8Gb Quad Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.82.00</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8.08.207</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.00</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.56</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1000Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">6.04.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8.08.232</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.43</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1000Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">6.04.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8.08.232</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.43</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">1.75.07</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">9.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.64</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">1.75.07</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">9.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.64</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">1.75.07</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">9.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.64</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">1.75.07</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">9.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.64</p>\n\t\t\t</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"QLOGIC","sw_key_expectedpath":"firmware:QLOGIC"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960KXAVL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304b5841564c","Version":"HPK3"},{"DeviceName":"VO001920KXAVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304b58415650","Version":"HPK3"},{"DeviceName":"VO003840KXAVQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304b58415651","Version":"HPK3"},{"DeviceName":"VO007680KXAVR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304b58415652","Version":"HPK3"},{"DeviceName":"MO000800KXAVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304b5841564e","Version":"HPK3"},{"DeviceName":"MO001600KXAVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b58415654","Version":"HPK3"},{"DeviceName":"MO003200KXAVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b58415655","Version":"HPK3"},{"DeviceName":"MO006400KXAVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b58415656","Version":"HPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following NVME drive models: VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のNVMEドライブモデルのファームウェアを提供します。VO000960KXAVL、VO001920KXAVP、VO003840KXAVQ、VO007680KXAVR、MO000800KXAVN、MO001600KXAVT、MO003200KXAVU、MO006400KXAVV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online NVMe SSD Flash Component for Windows (x64) -&nbsp;VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp; HPK3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPK2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPK2<br />\n<br />\n<strong><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Sever 2022.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">This Firmware release contains various drive interoperability enhancements and code fixes accumulated since the last firmware release, as well as a change to disable MCTP over PCIe VDM function per requested of HPE, and a PHY setting change for improved compatibility with Intel Ice Lake based Gen10+ DL360 platform.&nbsp;</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00115201en_us</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5888008","datemodified":"2021-08-17T12:50:00","file_list":["cp049303.xml","cpqsetup.exe","KPE80X0AHPK3.rel","payload.json","setup.dll"],"md5sum":"7023f617c928074cd73db126d95b2853","name":"cp049303.exe","release":"2021-08-17T12:42:29","revision":"0","sha1sum":"9873cd9fea32d98b5cf9d6110175a29a01ce891d","size":"5MB","target_guids":["562340a5-304f-3030-3936-304b5841564c","562340a5-304f-3130-3932-304b58415650","562340a5-304f-3330-3834-304b58415651","562340a5-304f-3730-3638-304b58415652","4d2340a5-304f-3030-3830-304b5841564e","4d2340a5-304f-3130-3630-304b58415654","4d2340a5-304f-3330-3230-304b58415655","4d2340a5-304f-3630-3430-304b58415656"],"type_of_change":"2","version":"HPK3"}],"id":{"product":"912bdc2895264227ab4d6d2895102ac1","version":"4dc299694aed4c4f9e3e9ed0f90588c8"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) - VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - VO000960KXAVL、VO001920KXAVP、VO003840KXAVQ、VO007680KXAVR、MO000800KXAVN、MO001600KXAVT、MO003200KXAVU、MO006400KXAVVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VO000960KXAVL","target_guid":"562340a5-304f-3030-3936-304b5841564c","type":"nvme"},{"id":"MO000800KXAVN","target_guid":"4d2340a5-304f-3030-3830-304b5841564e","type":"nvme"},{"id":"MO001600KXAVT","target_guid":"4d2340a5-304f-3130-3630-304b58415654","type":"nvme"},{"id":"MO003200KXAVU","target_guid":"4d2340a5-304f-3330-3230-304b58415655","type":"nvme"},{"id":"MO006400KXAVV","target_guid":"4d2340a5-304f-3630-3430-304b58415656","type":"nvme"},{"id":"VO003840KXAVQ","target_guid":"562340a5-304f-3330-3834-304b58415651","type":"nvme"},{"id":"VO007680KXAVR","target_guid":"562340a5-304f-3730-3638-304b58415652","type":"nvme"},{"id":"VO001920KXAVP","target_guid":"562340a5-304f-3130-3932-304b58415650","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-17T12:32:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This Firmware release contains various drive interoperability enhancements and code fixes accumulated since the last firmware release, as well as a change to disable MCTP over PCIe VDM function per requested of HPE, and a PHY setting change for improved compatibility with Intel Ice Lake based Gen10+ DL360 platform.&nbsp;</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00115201en_us</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Sever 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This Firmware release contains various drive interoperability enhancements and code fixes accumulated since the last firmware release, as well as a change to disable MCTP over PCIe VDM function per requested of HPE, and a PHY setting change for improved compatibility with Intel Ice Lake based Gen10+ DL360 platform.&nbsp;</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00115201en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO007680KXAVR","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO006400KXAVV","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO001600KXAVT","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO001920KXAVP","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO000960KXAVL","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO003840KXAVQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO003200KXAVU","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO000800KXAVN","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"本產品包含適用於在 SUSE Linux Enterprise Server 12 x86_64 下執行之 HPE Broadcom NetXtreme-E NIC 的驅動程式。"},{"lang":"en","x_late":"This product contains the drivers for the HPE Broadcom NetXtreme-E NICs running under SUSE Linux Enterprise Server 12 x86_64."},{"lang":"ko","x_late":"이 제품에는 SUSE Linux Enterprise Server 12 x86_64에서 실행 중인 HPE Broadcom NetXtreme-E NIC용 드라이버가 포함되어 있습니다."},{"lang":"cn","x_late":"本产品包含SUSE Linux Enterprise Server 12 x86_64版HPE Broadcom NetXtreme-E网卡驱动程序。"},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12 x86_64で動作するHPE Broadcom NetXtreme-E Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"336041","datemodified":"2021-01-14T07:28:37","file_list":["./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/bnxt_en.ko","./lib/modules/4.12.14-94.41-default/updates/drivers","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/share/smartupdate/bnxt_en-kmp-default/component.xml"],"md5sum":"2e0731ddfdfc03cf67b497f1ef5bd57d","name":"bnxt_en-kmp-default-1.10.2_k4.12.14_94.41-218.0.67.0.sles12sp4.x86_64.rpm","release":"2021-01-14T07:09:04","revision":"0","sha1sum":"a6d2654c5c9b84c5f6af612fae798babac0097d3","size":"328KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ece34fd967"],"type_of_change":"0","version":"1.10.2-218.0.67.0"},{"bytes":"305099","datemodified":"2021-01-14T07:25:00","file_list":["./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/bnxt_en.ko","./lib/modules/4.12.14-120-default/updates/drivers","./lib/modules/4.12.14-120-default/updates/drivers/infiniband","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/share/smartupdate/bnxt_en-kmp-default/component.xml"],"md5sum":"ae18f9765b3b422e24e0916b98302442","name":"bnxt_en-kmp-default-1.10.2_k4.12.14_120-218.0.67.0.sles12sp5.x86_64.rpm","release":"2021-01-14T07:09:04","revision":"0","sha1sum":"d2350fa756ec97315c9bc63364d358b9ca78eb69","size":"297KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ece34fd967"],"type_of_change":"0","version":"1.10.2-218.0.67.0"}],"id":{"product":"4449ff05e7054e05a09904ed0fed74a8","version":"11a8ca6bd9b948daa9e049fbb7fe0c54"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation instructions.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 SUSE Linux Enterprise Server 12 x86_64 的 HPE Broadcom NetXtreme-E 驅動程式"},{"lang":"en","x_late":"HPE Broadcom NetXtreme-E Drivers for SUSE Linux Enterprise Server 12 x86_64"},{"lang":"ko","x_late":"SUSE Linux Enterprise Server 12 x86_64용 HPE Broadcom NetXtreme-E 드라이버"},{"lang":"cn","x_late":"SUSE Linux Enterprise Server 12 x86_64版HPE Broadcom NetXtreme-E驱动程序"},{"lang":"ja","x_late":"HPE Broadcom NetXtreme-E ドライバー for SUSE Linux Enterprise Server 12 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>This product now supports SUSE Linux Enterprise Server 12 Service Pack 5.</li>\n\t<li>This product now sets Maximum Transmission Unit(MTU) default value from firmware returned value.</li>\n\t<li>This product now not support user establishing connections using RDMA communication manager(CM) when Priority-based Flow Control (PFC) configured VLAN ID is 0</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>This product corrects an issue which offload is not happening on bond(vf and virtio) interface after the fail over with VF as the active slave</li>\n\t<li>This product corrects an issue which driver loading failed on kdump kernel.</li>\n\t<li>This product corrects an issue which RoCE driver causes input&ndash;output memory management unit(IOMMU) warnings</li>\n\t<li>This product corrects an issue which RoCE Link Aggregation (RoCE LAG) when Maximum Transmission Unit(MTU) was changed.</li>\n\t<li>This product corrects an issue which Link up failed after resuming from hibernation</li>\n\t<li>This product corrects an issue which Virtual Function RoCE driver causes Virtual Machine to be rebooted</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>This product now supports PAM4 speeds information in&nbsp;ethtool tools&nbsp;</p>\n","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where system crashed on doing driver unload load in loop when running broadcast traffic</li>\n\t<li>This product addresses an issue where bnxt_en module crashes with NULL pointer deference before ifup(bring up network interface)</li>\n\t<li>This product addresses an issue where kernel panic after PCIe AER(Advanced Error Reporting) device recovery successful</li>\n\t<li>This product addresses an issue where bnxt_en crashes with NULL pointer dereference when enabling SRIOV</li>\n\t<li>This product correct an error where ethtool -S tx_bytes and rx_bytes counter values far exceed actual values</li>\n\t<li>This product correct an error message when querying hwmon temperature on VF via sysfs</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"bnxt_en-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"bnxt_en-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"bnxt_en-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"bnxt_en-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Mellanox CX4LX and CX5 Ethernet NICs for Microsoft Windows Server 2016."},{"lang":"ja","x_late":"このコンポーネントパッケージは、HPE Mellanox CX4LXおよびCX5 Ethernet NIC for Microsoft Windows Server 2016用のドライバーを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1969144","datemodified":"2021-08-31T13:55:20","file_list":["cp048373.xml","cpqsetup.exe","cp_data.xml","install.xml","mlx5.cat","mlx5.inf","mlx5.sys","mlx5ui.dll","nicdrvr.dll"],"md5sum":"23db4d94a5c19a15f2998979beaf58bc","name":"cp048373.exe","release":"2021-08-31T13:40:05","revision":"0","sha1sum":"0c52a49e5c4473e56be8fb2c42eb07583c73be8d","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"type_of_change":"0","version":"2.70.24728.0"}],"id":{"product":"ed4e13cf761c496aa2355b8c9f267dd3","version":"b0f416fa50bd4f5d92eff95774802561"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>インストールボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Mellanox CX4LX and CX5 Driver for Microsoft Windows Server 2016"},{"lang":"ja","x_late":"HPE Mellanox CX4LXおよびCX5ドライバー for Microsoft Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"1018","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101815900282","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1014","subdev":"00c7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1014159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1014","subdev":"00c8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1014159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"1016","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1016159002c1","type":"pci","ven":"15B3"},{"dev":"1016","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1016159002c1","type":"pci","ven":"15B3"},{"dev":"1016","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1016159000d3","type":"pci","ven":"15B3"},{"dev":"1016","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1016159000d4","type":"pci","ven":"15B3"},{"dev":"1018","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101815900246","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T02:04:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This product addresses a Windows Stop Error (BSOD) seen when running Mellanox NdStat Utility (mlx5cmd -ndstat) while ND connections was closing.</li>\n\t<li>This product corrects driver loading failures seen due to incorrect INF file.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product correct an issue where mlx5cmd tools reporting of the OS version that a VF is running.</li>\n\t<li>This product correct an issue where incorrect report related to the firmware traces to be logged ( FwTracer) &nbsp;feature on the VF</li>\n\t<li>This product correct an issue where prevented the package downgrade from replacing mlxdevx.dll in the system folder.</li>\n\t<li>This product correct an issue which cause TCP connection to drop</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"mlx5.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWFGF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SNEMOTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757464746","Version":"HPG3"},{"DeviceName":"MB002000GWFGH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SNEMOTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757464748","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB002000GWFGH and MB001000GWFGF "},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MB002000GWFGH および MB001000GWFGF "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB002000GWFGH and MB001000GWFGF Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/NewFeatures :</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3324248","datemodified":"2021-07-23T19:21:22","file_list":["cp048559.xml","cpqsetup.exe","payload.json","setup.dll","SNEMOTG3.rel"],"md5sum":"c70888cc236100018bd7c2effda40003","name":"cp048559.exe","release":"2021-07-23T19:13:04","revision":"0","sha1sum":"85185c349d09fa528e189d57fb13f8882df1aa45","size":"3MB","target_guids":["4d2340a5-3042-3130-3030-304757464746","4d2340a5-3042-3230-3030-304757464748"],"type_of_change":"0","version":"HPG3"}],"id":{"product":"606295772f834fc984488410e9459b3e","version":"293e567f65b14f3fb8913e4b8e1f6888"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB002000GWFGH and MB001000GWFGF Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows(x64) - MB002000GWFGHおよびMB001000GWFGFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB001000GWFGF","target_guid":"4d2340a5-3042-3130-3030-304757464746","type":"sata"},{"id":"MB002000GWFGH","target_guid":"4d2340a5-3042-3230-3030-304757464748","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T06:02:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB001000GWFGF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB002000GWFGH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GVYZB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPETG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304756595a42","Version":"HPG4"},{"DeviceName":"MB4000GVYZA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPETG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304756595a41","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB6000GVYZB and MB4000GVYZA Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： MB6000GVYZBおよびMB4000GVYZAドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB6000GVYZB and MB4000GVYZA Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:&nbsp;&nbsp;</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5378582","datemodified":"2021-07-23T07:33:55","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7d4aa47f-HPG4-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7d4aa47f-HPG4-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7d4aa47f-HPG4-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7d4aa47f-HPG4-6.1/CP048170.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7d4aa47f-HPG4-6.1/SMBPETG4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7d4aa47f-HPG4-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7d4aa47f-HPG4-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7d4aa47f-HPG4-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7d4aa47f-HPG4-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048170.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048170.scexe"],"md5sum":"bb1b0b1835b29a62a2813cbac53c9a70","name":"firmware-hdd-0a7d4aa47f-HPG4-6.1.x86_64.rpm","release":"2021-07-23T07:22:14","revision":"0","sha1sum":"9482763405db73bc80165119a6ab7bbe79a7f5fa","size":"5MB","target_guids":["002340a5-4d00-3642-3030-304756595a42","002340a5-4d00-3442-3030-304756595a41"],"type_of_change":"1","version":"HPG4"}],"id":{"product":"d7e21057ac6640f0b343d9d0d83a30a1","version":"968fcda0c0454b388ca6436102d94916"},"installation":{"command":"CP040339.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">Follow the instructions on the screen.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">画面の指示に従います。</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB6000GVYZB and MB4000GVYZA Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB6000GVYZBおよびMB4000GVYZAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB4000GVYZA","target_guid":"002340a5-4d00-3442-3030-304756595a41","type":"sata"},{"id":"MB6000GVYZB","target_guid":"002340a5-4d00-3642-3030-304756595a42","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T19:51:37","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000GVYZB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB4000GVYZA","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB1000GDUNU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3142-3030-304744554e55","Version":"HPG4"},{"DeviceName":"MB2000GDUNV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304744554e56","Version":"HPG4"},{"DeviceName":"MB3000GDUPA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304744555041","Version":"HPG4"},{"DeviceName":"MB4000GDUPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304744555042","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB1000GDUNU, MB2000GDUNV, MB3000GDUPA and MB4000GDUPB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB1000GDUNU, MB2000GDUNV, MB3000GDUPA&nbsp;and MB4000GDUPB drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<ul>\n\t<li>Firmware cannot be downgraded to HPG3 after updating to HPG4.</li>\n</ul>\n"}],"files":[{"bytes":"16940219","datemodified":"2021-08-26T15:29:34","file_list":["/CP048342_BUILD_2.data","/CP048342.vmexe","/CP048342.vmexe64","/CP048342.vmfile","/CP048342_VMw.zip","/CP048342.xml","/payload.json","/CP048342_VMw.zip/index.xml","/CP048342_VMw.zip/vendor-index.xml","/CP048342_VMw.zip/metadata.zip","/CP048342_VMw.zip/vib20/CP048342/HPE_bootbank_CP048342_HPG4.2-7.0.0.15843807.vib","/CP048342_VMw.zip/metadata.zip/vendor-index.xml","/CP048342_VMw.zip/metadata.zip/vmware.xml","/CP048342_VMw.zip/metadata.zip/vibs/CP048342--2210292570397044906.xml","/CP048342_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048342_HPG4.2-7.0.0.15843807.xml"],"md5sum":"7efd88a41ac314aa269a545c03bb22ed","name":"CP048342.zip","release":"2021-08-26T15:24:31","revision":"0","sha1sum":"48d92b5d93c7cb726c1b1d116e662abcbf72e304","size":"16MB","target_guids":["002340a5-4d00-3142-3030-304744554e55","002340a5-4d00-3242-3030-304744554e56","002340a5-4d00-3342-3030-304744555041","002340a5-4d00-3442-3030-304744555042"],"type_of_change":"1","version":"HPG4","vib_list":[{"name":"CP048342","version":"HPG4.2-7.0.0.15843807"}]}],"id":{"product":"9635a1b56d544167b79937e43283b144","version":"4dd2ac0b3e0f418cbf8b5b67fe68effa"},"installation":{"command":"CP040506.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB1000GDUNU, MB2000GDUNV, MB3000GDUPA and MB4000GDUPB Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor ESXi - MB1000GDUNU、MB2000GDUNV、MB3000GDUPA、およびMB4000GDUPBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB1000GDUNU","target_guid":"002340a5-4d00-3142-3030-304744554e55","type":"sata"},{"id":"MB2000GDUNV","target_guid":"002340a5-4d00-3242-3030-304744554e56","type":"sata"},{"id":"MB3000GDUPA","target_guid":"002340a5-4d00-3342-3030-304744555041","type":"sata"},{"id":"MB4000GDUPB","target_guid":"002340a5-4d00-3442-3030-304744555042","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-06T14:41:36","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB2000GDUNV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB3000GDUPA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB4000GDUPB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB1000GDUNU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GZCNE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K511HPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-30475a434e45","Version":"HPG1"},{"DeviceName":"VK000960GZCNF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K511HPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-30475a434e46","Version":"HPG1"},{"DeviceName":"VK001920GZCNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K511HPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-30475a434e48","Version":"HPG1"},{"DeviceName":"VK003840GZCNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K511HPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-30475a434e4b","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK"},{"lang":"ja","x_late":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VK000480GZCNE、VK000960GZCNF、VK001920GZCNHおよびVK003840GZCNK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;-&nbsp;VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK&nbsp; Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"7948904","datemodified":"2021-07-27T13:18:42","file_list":["cp049155.xml","cpqsetup.exe","K511HPG1.rel","payload.json","setup.dll"],"md5sum":"b2941786a7bac047661a34f73a4a7a29","name":"cp049155.exe","release":"2021-07-27T13:10:10","revision":"0","sha1sum":"4a2b2fe2db7b623c383d41a7700929d850e01c69","size":"7MB","target_guids":["562340a5-304b-3030-3438-30475a434e45","562340a5-304b-3030-3936-30475a434e46","562340a5-304b-3130-3932-30475a434e48","562340a5-304b-3330-3834-30475a434e4b"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"2a95310f5de64c9fad6c33cfacf5d307","version":"681fcc4ffa2d469292f817a56dab6179"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"http://www.hpe.com/jp/servers/spp_dl　\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK  Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for Windows (x64) - VK000480GZCNE、VK000960GZCNF、VK001920GZCNHおよびVK003840GZCNKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VK000480GZCNE","target_guid":"562340a5-304b-3030-3438-30475a434e45","type":"sata"},{"id":"VK000960GZCNF","target_guid":"562340a5-304b-3030-3936-30475a434e46","type":"sata"},{"id":"VK001920GZCNH","target_guid":"562340a5-304b-3130-3932-30475a434e48","type":"sata"},{"id":"VK003840GZCNK","target_guid":"562340a5-304b-3330-3834-30475a434e4b","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-27T12:56:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>The FW version is Changed from HPG0 to HPG1. Changed the thermal throttling scheme. SMART 60℃ was matched with Tcase 70℃ and Run the thermal throttling at SMART 65℃.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK000960GZCNF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GZCNE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GZCNK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GZCNH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWJRR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06ACHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574a5252","Version":"HPG4"},{"DeviceName":"MB008000GWJRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06ACHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-3047574a5254","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB006000GWJRR and MB008000GWJRT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB006000GWJRR and MB008000GWJRT Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"16230792","datemodified":"2021-08-27T13:25:28","file_list":["/CP048447_BUILD_2.data","/CP048447.vmexe","/CP048447.vmexe64","/CP048447.vmfile","/CP048447_VMw.zip","/CP048447.xml","/payload.json","/CP048447_VMw.zip/index.xml","/CP048447_VMw.zip/vendor-index.xml","/CP048447_VMw.zip/metadata.zip","/CP048447_VMw.zip/vib20/CP048447/HPE_bootbank_CP048447_HPG4.2-7.0.0.15843807.vib","/CP048447_VMw.zip/metadata.zip/vendor-index.xml","/CP048447_VMw.zip/metadata.zip/vmware.xml","/CP048447_VMw.zip/metadata.zip/vibs/CP048447-6076430416749615820.xml","/CP048447_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048447_HPG4.2-7.0.0.15843807.xml"],"md5sum":"62630d1715a9ee83e30bec5522a0c9ad","name":"CP048447.zip","release":"2021-08-27T13:20:44","revision":"0","sha1sum":"9f852d979ee417ad86003a74350519a73fbb98cc","size":"15MB","target_guids":["4d2340a5-3042-3630-3030-3047574a5252","4d2340a5-3042-3830-3030-3047574a5254"],"type_of_change":"1","version":"HPG4","vib_list":[{"name":"CP048447","version":"HPG4.2-7.0.0.15843807"}]}],"id":{"product":"1cadb74f384743de9dfa8d9d6bc9f7b5","version":"415899c6be624816abdd4d41ab75b563"},"installation":{"command":"CP041677.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします。</li>\n\t<li>CPXXXXXX.vmexe(ESXi 6.7 &以前のバージョン)およびCPXXXXXX.vmexe64(ESXi 7.0)は、次のコマンドを使用して実行可能です:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod x CPXXXXXX.vmexe    または    chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPXXXXXX.vmexe(または)./CPXXXXXX.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB006000GWJRR and MB008000GWJRT Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB006000GWJRRおよびMB008000GWJRTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB008000GWJRT","target_guid":"4d2340a5-3042-3830-3030-3047574a5254","type":"sata"},{"id":"MB006000GWJRR","target_guid":"4d2340a5-3042-3630-3030-3047574a5252","type":"sata"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-10T15:28:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000GWJRR","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB008000GWJRT","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GWAYN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHHaseFG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-30475741594e","Version":"HPG5"},{"DeviceName":"MB008000GWAYL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHHaseFG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-30475741594c","Version":"HPG5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB010000GWAYN and MB008000GWAYL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;&nbsp;MB010000GWAYN and MB008000GWAYL Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG4</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>This code corrects a potential data integrity issue related to unaligned write commands.This issue was only found in supplier ongoing lab testing.</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"6053053","datemodified":"2021-07-23T07:21:53","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-cc819d4bff-HPG5-7.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-cc819d4bff-HPG5-7.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-cc819d4bff-HPG5-7.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-cc819d4bff-HPG5-7.1/CP048135.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-cc819d4bff-HPG5-7.1/HLIBRHHaseFG5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-cc819d4bff-HPG5-7.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-cc819d4bff-HPG5-7.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-cc819d4bff-HPG5-7.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-cc819d4bff-HPG5-7.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048135.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048135.scexe"],"md5sum":"2e9e3ac40fa71172fc9387ba328e5927","name":"firmware-hdd-cc819d4bff-HPG5-7.1.x86_64.rpm","release":"2021-07-23T07:09:15","revision":"0","sha1sum":"65bab66c60cf0d85b7f6b8c571aa00a3a21a295b","size":"5MB","target_guids":["4d2340a5-3042-3031-3030-30475741594e","4d2340a5-3042-3830-3030-30475741594c"],"type_of_change":"2","version":"HPG5"}],"id":{"product":"ff5f0967b6c84e77920662313dc42a52","version":"4aa47182229f4436b94105f6e6ff352e"},"installation":{"command":"CP040327.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB010000GWAYN and MB008000GWAYL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB010000GWAYNおよびMB008000GWAYLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB010000GWAYN","target_guid":"4d2340a5-3042-3031-3030-30475741594e","type":"sata"},{"id":"MB008000GWAYL","target_guid":"4d2340a5-3042-3830-3030-30475741594c","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-26T11:53:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>This code corrects a potential data integrity issue related to unaligned write commands.This issue was only found in supplier ongoing lab testing.</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This code corrects a potential data integrity issue related to unaligned write commands.This issue was only found in supplier ongoing lab testing.</li>\n</ul>","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB010000GWAYN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB008000GWAYL","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Intel ixn 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Microsoft Windows Server 2019で動作しているHPE Intel ixn 10 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1027088","datemodified":"2021-01-08T18:15:53","file_list":["cp046115.xml","cpqsetup.exe","cp_data.xml","install.xml","ixn68x64.cat","ixn68x64.din","ixn68x64.inf","ixn68x64.sys","ixnmsg.dll","nicdrvr.dll"],"md5sum":"bc7670e43486949a772e857b86bdd582","name":"cp046115.exe","release":"2021-01-08T18:02:04","revision":"0","sha1sum":"cb20e39880950287825851cb87fbf1379caf5224","size":"0MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec619e0b4b"],"type_of_change":"0","version":"4.1.197.0"}],"id":{"product":"7a38c76de8ff4383970907d2998b1740","version":"93e6920214dc4919bd95c3a400c54ef8"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel ixn Driver for Windows Server 2019"},{"lang":"ja","x_late":"HPE Intel ixnドライバー for Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product contains Windows system update supported improvements.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product is updated to maintain compatibility with updated .cat file.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"ixn68x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWEZB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757455a42","Version":"HPGG"},{"DeviceName":"VK000480GWEZC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757455a43","Version":"HPGG"},{"DeviceName":"VK000960GWEZD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757455a44","Version":"HPGG"},{"DeviceName":"VK001920GWEZE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757455a45","Version":"HPGG"},{"DeviceName":"MK000240GWEZF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3234-304757455a46","Version":"HPGG"},{"DeviceName":"MK000480GWEZH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757455a48","Version":"HPGG"},{"DeviceName":"MK000960GWEZK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757455a4b","Version":"HPGG"},{"DeviceName":"MK001920GWHRU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304757485255","Version":"HPGG"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK000240GWEZB, VK000480GWEZC, VK000960GWEZD, VK001920GWEZE, MK000240GWEZF, MK000480GWEZH, MK000960GWEZK and MK001920GWHRU"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;&nbsp;(x64)&nbsp;- VK000240GWEZB, VK000480GWEZC, VK000960GWEZD, VK001920GWEZE, MK000240GWEZF, MK000480GWEZH, MK000960GWEZK and MK001920GWHRU Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGG<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGB<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPGB</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3133016","datemodified":"2021-07-25T18:36:17","file_list":["cp048636.xml","cpqsetup.exe","M5100SGG.rel","payload.json","setup.dll"],"md5sum":"1009e0bca52b1f7cc68bc73cb5afb2dd","name":"cp048636.exe","release":"2021-07-25T18:28:05","revision":"0","sha1sum":"15a64674e7d1fe2c4c3bb828254eda28989e6258","size":"2MB","target_guids":["562340a5-304b-3030-3234-304757455a42","562340a5-304b-3030-3438-304757455a43","562340a5-304b-3030-3936-304757455a44","562340a5-304b-3130-3932-304757455a45","4d2340a5-304b-3030-3234-304757455a46","4d2340a5-304b-3030-3438-304757455a48","4d2340a5-304b-3030-3936-304757455a4b","4d2340a5-304b-3130-3932-304757485255"],"type_of_change":"1","version":"HPGG"}],"id":{"product":"349d4407749e4a9fa71df176f3e03e78","version":"d178af394a5646a584827a312f5048a7"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK000240GWEZB, VK000480GWEZC, VK000960GWEZD, VK001920GWEZE, MK000240GWEZF, MK000480GWEZH, MK000960GWEZK and MK001920GWHRU Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - VK000240GWEZB、VK000480GWEZC、VK000960GWEZD、VK001920GWEZE、MK000240GWEZF、MK000480GWEZH、MK000960GWEZK、およびMK001920GWHRUドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MK001920GWHRU","target_guid":"4d2340a5-304b-3130-3932-304757485255","type":"sata"},{"id":"VK001920GWEZE","target_guid":"562340a5-304b-3130-3932-304757455a45","type":"sata"},{"id":"MK000240GWEZF","target_guid":"4d2340a5-304b-3030-3234-304757455a46","type":"sata"},{"id":"VK000240GWEZB","target_guid":"562340a5-304b-3030-3234-304757455a42","type":"sata"},{"id":"MK000480GWEZH","target_guid":"4d2340a5-304b-3030-3438-304757455a48","type":"sata"},{"id":"VK000480GWEZC","target_guid":"562340a5-304b-3030-3438-304757455a43","type":"sata"},{"id":"MK000960GWEZK","target_guid":"4d2340a5-304b-3030-3936-304757455a4b","type":"sata"},{"id":"VK000960GWEZD","target_guid":"562340a5-304b-3030-3936-304757455a44","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T15:58:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Improvements to Product Quality and Reliability.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK001920GWHRU","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000240GWEZF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWEZH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWEZC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GWEZE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWEZD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWEZK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWEZB","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware for Converged Network and Network only adapters. \n\n"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"7590760","datemodified":"2021-08-27T06:30:22","file_list":["brcmflashStandalone-windows-12.0.1345.0-1/firmware/","brcmflashStandalone-windows-12.0.1345.0-1/firmware/oc14-12.0.1345.0.ufi","brcmflashStandalone-windows-12.0.1345.0-1/win/","brcmflashStandalone-windows-12.0.1345.0-1/win/brcmflash.bat","brcmflashStandalone-windows-12.0.1345.0-1/win/brcmwinlpcfg.bat","brcmflashStandalone-windows-12.0.1345.0-1/win/x64/","brcmflashStandalone-windows-12.0.1345.0-1/win/x64/brcmflash.exe","brcmflashStandalone-windows-12.0.1345.0-1/win/x64/BrcmMILI.dll","brcmflashStandalone-windows-12.0.1345.0-1/win/x64/brcmwinlpcfg.exe","brcmflashStandalone-windows-12.0.1345.0-1/win/x64/firmware/","brcmflashStandalone-windows-12.0.1345.0-1/win/x64/libbrcmdfc.dll","brcmflashStandalone-windows-12.0.1345.0-1/win/x64/RM.INI","cp048540.xml","cpqsetup.exe","fwmatrix.txt","brcmflashStandalone-windows-12.0.1345.0-1/win/x64/fwmatrix.txt","hpe_fw_matrix.xml","installer.dll","payload.json","readme.txt","brcmflashStandalone-windows-12.0.1345.0-1/win/x64/readme.txt","reference.xml"],"md5sum":"ab80867b4c3291fe91ef365134721d7b","name":"cp048540.exe","release":"2021-08-27T06:15:05","revision":"0","sha1sum":"e342f049053f0d03abe125d6897bdcdbe3876aed","size":"7MB","target_guids":[],"type_of_change":"1","version":"2021.10.01"}],"id":{"product":"857fb3c2e7ab4dc9bb91f1a3aee0702f","version":"ce7b03f2fff942be974ed9f37bf86353"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p dir=\"LTR\">Download the Smart Component to a directory on your hard drive and change to that directory.</p>\n\n<p>The downloaded file is a self-extracting executable with a filename based on the Component Number.<br />\nFrom that drive and directory, execute the downloaded file.<br />\n<br />\nClick the &quot;Install&quot; button to proceed with the installation.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Converged Network Adapters for Microsoft Windows Server 2016/2019(x64)"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"0724","subdev":"21D4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"21D4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"8153","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8153","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8144","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"8144","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"220A","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"220A","subven":"103C","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T11:01:01","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This Firmware package contains following firmware version:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot BIOS</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 10Gb 2-port 556FLR-T Adapter</td>\n\t\t\t<td>10Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1345.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</td>\n\t\t\t<td>10Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1345.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE CN1200E Dual Port Converged Network Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1345.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE&nbsp;CN1200E-T Dual Port Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1345.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"}],"sw_keys":[{"name":"emulex_cna","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Broadcom Ethernet NICs running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品は、Red Hat Enterprise Linux 8下で動作するHPE Broadcom NetXtreme-E NIC用のドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"113716","datemodified":"2021-01-17T07:07:35","file_list":["./etc/depmod.d/tg3.conf","./lib/modules/4.18.0-193.el8.x86_64","./lib/modules/4.18.0-193.el8.x86_64/extra","./lib/modules/4.18.0-193.el8.x86_64/extra/tg3","./lib/modules/4.18.0-193.el8.x86_64/extra/tg3/tg3.ko","./usr/lib/.build-id","./usr/lib/.build-id/81","./usr/lib/.build-id/81/d9bc30cc5234ec43a2315b6aaafe8c2b0e2b92","./usr/share/smartupdate/kmod-tg3/component.xml"],"md5sum":"b7a2cba9a826ba8adf576b7870e4f84f","name":"kmod-tg3-3.139b-1.rhel8u2.x86_64.rpm","release":"2021-01-17T06:56:05","revision":"0","sha1sum":"2f630ae3af01eae4490904202351a8166a9d34a3","size":"111KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6"],"type_of_change":"0","version":"3.139b-1"},{"bytes":"113723","datemodified":"2021-01-17T07:02:40","file_list":["./etc/depmod.d/tg3.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/tg3","./lib/modules/4.18.0-240.el8.x86_64/extra/tg3/tg3.ko","./usr/lib/.build-id","./usr/lib/.build-id/0c","./usr/lib/.build-id/0c/7927ec8f2d2e366b346d9919d2a10812221738","./usr/share/smartupdate/kmod-tg3/component.xml"],"md5sum":"47ce80dcb0ca8c16c25b400e9a204e0f","name":"kmod-tg3-3.139b-1.rhel8u3.x86_64.rpm","release":"2021-01-17T06:56:05","revision":"0","sha1sum":"a59c0d0b5fd9268031783096ce6f84299c41c7ed","size":"111KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6"],"type_of_change":"0","version":"3.139b-1"}],"id":{"product":"17ede1952e7d40da9d3235daae0363d6","version":"e6297f5e156d4732b93f943910470377"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Broadcom tg3 Ethernet Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE Broadcom tg3 Ethernetドライバー for Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"165F","subdev":"22E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c22e8","type":"pci","ven":"14E4"},{"dev":"1665","subdev":"22BD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1665103c22bd","type":"pci","ven":"14E4"},{"dev":"165F","subdev":"1786","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c1786","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"169D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c169d","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"3383","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c3383","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"22BE","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c22be","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 8 Update 1.</p>\n","latest_fixes_x_late":"<p>This product corrects an issue which errata kernel loads inbox driver instead of this component after booting into OS</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 8 update 2 and Red Hat Enterprise Linux 8 update 3</p>\n","curr_fixes_x_late":"<p>The products fixes an a race condition issue where driver will still try to access the PHY(physical layer) although it was already brought down when the tg3 timer fires</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-tg3","sw_key_expectedpath":"software:rpm"},{"name":"kmod-tg3","sw_key_expectedpath":"software:rpm"},{"name":"kmod-tg3","sw_key_expectedpath":"software:rpm"},{"name":"kmod-tg3","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH0300JEDHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SVKBPND4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3330-304a45444843","Version":"HPD4"},{"DeviceName":"EH0450JEDHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SVKBPND4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3435-304a45444844","Version":"HPD4"},{"DeviceName":"EH0600JEDHE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SVKBPND4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3630-304a45444845","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EH0300JEDHC, EH0450JEDHD, and EH0600JEDHE"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 EH0300JEDHC、EH0450JEDHD、およびEH0600JEDHE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - EH0300JEDHC, EH0450JEDHD&nbsp;and EH0600JEDHE Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3542112","datemodified":"2021-07-24T05:23:00","file_list":["cp048520.xml","cpqsetup.exe","payload.json","setup.dll","SVKBPND4.rel"],"md5sum":"b91721019b6369e5682cb0e2dc7cb83f","name":"cp048520.exe","release":"2021-07-24T05:15:04","revision":"0","sha1sum":"8bdc399a57e8a32f495280eb6c3225838abd094a","size":"3MB","target_guids":["002340a5-4500-3048-3330-304a45444843","002340a5-4500-3048-3435-304a45444844","002340a5-4500-3048-3630-304a45444845"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"33a82ad709014bf88daa4d5451b9b3d6","version":"894bef47854a465fb0062fe9e66db032"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EH0300JEDHC, EH0450JEDHD and EH0600JEDHE Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows(x64)- EH0300JEDHC、EH0450JEDHD、およびEH0600JEDHEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EH0300JEDHC","target_guid":"002340a5-4500-3048-3330-304a45444843","type":"sas"},{"id":"EH0450JEDHD","target_guid":"002340a5-4500-3048-3435-304a45444844","type":"sas"},{"id":"EH0600JEDHE","target_guid":"002340a5-4500-3048-3630-304a45444845","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T10:35:01","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH0600JEDHE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0300JEDHC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0450JEDHD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG0300JEHLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFLRCD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3330-304a45484c56","Version":"HPD5"},{"DeviceName":"EG0600JEHMA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFLRCD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3630-304a45484d41","Version":"HPD5"},{"DeviceName":"EG0900JEHMB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFLRCD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3930-304a45484d42","Version":"HPD5"},{"DeviceName":"EG1200JEHMC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFLRCD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3230-304a45484d43","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG0300JEHLV, EG0600JEHMA, EG0900JEHMB and EG1200JEHMC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - EG0300JEHLV, EG0600JEHMA, EG0900JEHMB&nbsp;and EG1200JEHMC Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD3</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p><strong>&nbsp; &nbsp; &nbsp;&nbsp; </strong>None.</p>\n"}],"files":[{"bytes":"3638856","datemodified":"2021-07-24T06:48:25","file_list":["cp048482.xml","cpqsetup.exe","HCFLRCD5.rel","payload.json","setup.dll"],"md5sum":"641f8908d301f76163b31aea05f69728","name":"cp048482.exe","release":"2021-07-24T06:41:04","revision":"0","sha1sum":"f937be947ea8b37f554fb4149303fda15907c71a","size":"3MB","target_guids":["002340a5-4500-3047-3330-304a45484c56","002340a5-4500-3047-3630-304a45484d41","002340a5-4500-3047-3930-304a45484d42","002340a5-4500-3147-3230-304a45484d43"],"type_of_change":"1","version":"HPD5"}],"id":{"product":"5d9285c19f4844c191173be5431c0cba","version":"dfa9fa7533b74a77afc01c27842b0d31"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG0300JEHLV, EG0600JEHMA, EG0900JEHMB and EG1200JEHMC Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EG0300JEHLV、EG0600JEHMA、EG0900JEHMB、およびEG1200JEHMCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG1200JEHMC","target_guid":"002340a5-4500-3147-3230-304a45484d43","type":"sas"},{"id":"EG0300JEHLV","target_guid":"002340a5-4500-3047-3330-304a45484c56","type":"sas"},{"id":"EG0600JEHMA","target_guid":"002340a5-4500-3047-3630-304a45484d41","type":"sas"},{"id":"EG0900JEHMB","target_guid":"002340a5-4500-3047-3930-304a45484d42","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-14T04:35:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG0900JEHMB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG1200JEHMC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0600JEHMA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0300JEHLV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following storage controllers: HPE HBA(Host Bus Adapters) H221"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のストレージコントローラーのファームウェアを提供します。 HPE HBA（ホストバスアダプター）H221"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for Windows (x64) HPE Host Bus Adapters&nbsp;H221</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 15.10.10.00 (E)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 15.10.10.00 (D)<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;&nbsp;&nbsp;Improved Integration with Smart Update Manager</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong>&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"3061848","datemodified":"2018-12-13T08:40:55","file_list":["cp038049.xml","cpqsetup.exe","firmware.cfg","H210i_it.fw","H220i_it.fw","H220_it.fw","H221_it.fw","H222_it.fw","InstallDll.dll","mptsas2.rom","sas2flash.exe"],"md5sum":"66fb17f361e0d801067ca13665b87873","name":"cp038049.exe","release":"2018-12-13T14:39:03","revision":"0","sha1sum":"b7207de055f0e7d1b1d26f8ca67e97a346726a70","size":"2MB","target_guids":[],"type_of_change":"0","version":"15.10.10.00"}],"id":{"product":"defe118a27e24cc9962950a6158c3e89","version":"8519df5231bc487cb2e0ce94c464ab39"},"installation":{"command":"cpqsetup.exe","command_params":"/t \"H220i\" /t \"H220\" /t \"H222\" /t \"H210i\" /t \"H221\" /c","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a><strong>:</strong></strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li>\n\t<li>Run launch_sum.bat script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a><strong></strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>ディレクトリ\\SPP20xxxxx\\hp\\swpackagesにアップデートに必要なファームウェアをコピーします。</li>\n\t<li>ISOのルートにある launch_hpsum.sh スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows (x64) - HPE Host Bus Adapters H221"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows x64 - HPEホストバスアダプターH221"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_devices":[{"dev":"0087","subdev":"0042","subven":"1590","target_guid":"","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-12-02T07:37:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Improved Integration with Smart Update Manager.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Improved Integration with Smart Update Manager.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"}],"sw_keys":[{"name":"00441590","sw_key_expectedpath":"firmware:sd:hba"},{"name":"00461590","sw_key_expectedpath":"firmware:sd:hba"},{"name":"00411590","sw_key_expectedpath":"firmware:sd:hba"},{"name":"00431590","sw_key_expectedpath":"firmware:sd:hba"},{"name":"00421590","sw_key_expectedpath":"firmware:sd:hba"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800100","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置"},{"lang":"en","x_late":"Software - Storage"},{"lang":"ko","x_late":"소프트웨어 - 스토리지"},{"lang":"ja","x_late":"ソフトウェア - ストレージ"},{"lang":"cn","x_late":"软件 - 存储"}]}],"description":[{"lang":"en","x_late":"The Host Explorer communicates with the HPE 3PAR StoreServ system over an FC or iSCSI connection and enables the host to send detailed host configuration information to the HPE 3PAR StoreServ System. The information gathered from the Host Explorer is visible for uncreated hosts and assists with host creation and diagnosing host connectivity issues. "}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"1682304","datemodified":"2018-02-09T04:43:11","file_list":["cp034831.xml","cpqsetup.exe","hesetup.exe","HostExplorer-win2k12-3.2.1-0.x64.msi","HostExplorer-win2k16-3.2.1-0.x64.msi","HostExplorer-windows-3.2.1-0.x64.msi"],"md5sum":"6eaa3327221828d012b3872f674a5886","name":"cp034831.exe","release":"2018-02-09T04:08:03","revision":"0","sha1sum":"2129fd8429cb944a74b72b0d43e0f8c58b9db057","size":"1MB","target_guids":[],"type_of_change":"1","version":"3.2.1.0"}],"id":{"product":"d2758fac106e4fcd86a4e9b65fdf0119","version":"7c9e3001602d47ada84aad1f7ba11fd2"},"installation":{"command":"hesetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the smart component&nbsp;to host machine and run the smart component.</p>\n\n<p>HPE 3PAR HostExplorer smart component will be installed only if the host has connectivity&nbsp;to HPE&nbsp;3PAR StoreServ.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE 3PAR HostExplorer for Windows Server 2008 2012 and 2016 x64 Operating Systems"},{"lang":"ja","x_late":"Windows Server 2008 2012および2016 x64オペレーティング システム用のHPE 3PAR HostExplorer"}],"prerequisites":{"required_diskspace":{"size_kb":"5120"},"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"0","name":"Microsoft Windows Server 2008 x64","platform":"nt_x86-64","sr":"OEM"},{"edition":"srvr","major":"6","minor":"0","name":"Microsoft Windows Server 2008 x64 - Server Edition","platform":"nt_x86-64","sr":"OEM"},{"edition":"core","major":"6","minor":"0","name":"Microsoft Windows Server 2008 x64 - Server Core Edition","platform":"nt_x86-64","sr":"OEM"},{"edition":"ebs","major":"6","minor":"0","name":"Microsoft Windows Server 2008 Essential Business","platform":"nt_x86-64","sr":"OEM"},{"edition":"fndtn","major":"6","minor":"0","name":"Microsoft Windows Server 2008 Foundation Edition","platform":"nt_x86-64","sr":"OEM"},{"edition":"sbs","major":"6","minor":"0","name":"Microsoft Windows Server 2008 Small Business","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-03-07T06:35:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Following are the new enhancements added in this release:</p>\n\n<ul>\n\t<li>&nbsp;Tokens for detecting if the host is T10 DIF capable .</li>\n\t<li>&nbsp;Tokens for getting the&nbsp; Host Consumed Capacity, mount points and File System allocation units&nbsp;&nbsp;</li>\n\t<li>&nbsp;Token added for checking if a server is booting from SAN</li>\n\t<li>&nbsp;Support for Windows server 2016</li>\n</ul>\n","latest_fixes_x_late":"<p>The following issues are&nbsp;fixed for HPE 3PAR Host Explorer 3.2.0 release:&nbsp;</p>\n\n<ul>\n\t<li>&nbsp;IP address token can take multiple IPs of the host with comma seperated values.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Following are the new enhancements added in this release:</p>\n\n<ul>\n\t<li>Tokens for detecting if the host is T10 DIF capable .</li>\n\t<li>&nbsp;Tokens for getting the&nbsp; Host Consumed Capacity, mount points and File System allocation units&nbsp;</li>\n\t<li>&nbsp;Token added for checking if a server is booting from SAN</li>\n\t<li>Support for Windows server 2016</li>\n\t<li>HPE 3PAR Host Explorer Windows supports upgrade to 3.2.1.</li>\n\t<li>HPE 3PAR OS version compatibility check in HPE 3PAR Host Explorer</li>\n</ul>\n","curr_fixes_x_late":"<p>The following are the issues fixed in HPE 3PAR Host Explorer 3.2.1 release:</p>\n\n<ul>\n\t<li>IP address token can take multiple IPs of the host with comma seperated values.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"","value":"HP 3PAR StoreServ 7450 4-node Base"},{"key":"","value":"HP 3PAR StoreServ 7450 2-node Base"},{"key":"","value":"HP 3PAR StoreServ 10400 2.8-GHz 16GB Control/32GB Data Cache Upg Controller Node"},{"key":"","value":"HP 3PAR StoreServ 10800 32GB Control/64GB Data Cache Rack Configuration Base"},{"key":"","value":"HP 3PAR StoreServ 10400 32GB Control/64GB Data Cache Rack Configuration Base"},{"key":"","value":"HP 3PAR StoreServ 10400 32GB Control/64GB Data Cache Rackmount Config Base"},{"key":"","value":"HP 3PAR StoreServ 10400 2.8GHz 32GB Control/64GB Data Cache Controller Node"},{"key":"","value":"HP 3PAR StoreServ 7400c 4-node Field Integrated Storage Base"},{"key":"","value":"HP 3PAR StoreServ 10400 2.8GHz 32GB Control/64GB Data Cache Upgr Controller Node"},{"key":"","value":"HP 3PAR StoreServ 7400 4-node Storage Base for Storage Centric Rack"},{"key":"","value":"HP 3PAR StoreServ 7400c 2-node Field Integrated Storage Base"},{"key":"","value":"HP 3PAR StoreServ 7450 4-node Base for Storage Centric Rack"},{"key":"","value":"HP 3PAR StoreServ 7400 2-node Storage Base"},{"key":"","value":"HP 3PAR StoreServ 7440c 4-node Storage Base"},{"key":"","value":"HP 3PAR StoreServ 7400 4-node Storage Base"},{"key":"","value":"HP 3PAR StoreServ 7200 2-node Storage Base"},{"key":"","value":"HP 3PAR StoreServ 7400 2-node Storage Base for Storage Centric Rack"},{"key":"","value":"HP 3PAR StoreServ 7450c 2-node Storage Base"},{"key":"","value":"HP 3PAR StoreServ 10800 2.8-GHz 32GB Control/64GB Data Cache Controller Node"},{"key":"","value":"HP 3PAR StoreServ 10800 3PAR 2.8-GHz 32GB Control/64GB Data Upg Controller Node"},{"key":"","value":"HP 3PAR StoreServ 7450 2-node Base for Storage Centric Rack"},{"key":"","value":"HP 3PAR StoreServ 7450c 2-node Storage Base for Storage Centric Rack"},{"key":"","value":"HP 3PAR StoreServ 7450c 4-node Storage Base for Storage Centric Rack"},{"key":"","value":"HP 3PAR StoreServ 7450c 4-node Storage Base"},{"key":"","value":"HP 3PAR StoreServ 7200c 2-node Field Integrated Storage Base"},{"key":"","value":"HP 3PAR StoreServ 7400c 4-node Storage Base for Storage Centric Rack"},{"key":"","value":"HP 3PAR StoreServ 7440c 2-node Storage Base"},{"key":"","value":"HP 3PAR StoreServ 7200c 2-node Storage Base"},{"key":"","value":"HP 3PAR StoreServ 7400c 2-node Storage Base for Storage Centric Rack"},{"key":"","value":"HP 3PAR StoreServ 7200c 2-node Storage Base for Storage Centric Rack"},{"key":"","value":"HP 3PAR StoreServ 7440c 4-node Storage Base for Storage Centric Rack"},{"key":"","value":"HP 3PAR StoreServ 7440c 2-node Storage Base for Storage Centric Rack"},{"key":"","value":"HP 3PAR StoreServ 7450c 4-node Field Integrated Storage Base"},{"key":"","value":"HP 3PAR StoreServ 7200 2-node Storage Base for Storage Centric Rack"}],"sw_keys":[{"name":"TpdHostAgent.exe","sw_key_expectedpath":"%PROGRAMFILES%\\Host Explorer"},{"name":"3PAR Host Explorer","sw_key_expectedpath":"software:sd:3parhostexplorer"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCM6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5856-554c38303047","Version":"GPK3"},{"DeviceName":"KCM6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5856-554c31543630","Version":"GPK3"},{"DeviceName":"KCM6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5856-554c33543230","Version":"GPK3"},{"DeviceName":"KCM6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5856-554c36543430","Version":"GPK3"},{"DeviceName":"KCM6XRUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5852-554c39363047","Version":"GPK3"},{"DeviceName":"KCM6XRUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5852-554c31543932","Version":"GPK3"},{"DeviceName":"KCM6XRUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5852-554c33543834","Version":"GPK3"},{"DeviceName":"KCM6XRUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5852-554c37543638","Version":"GPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Linux (x64) - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68 Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK3</p>\n\n<p><strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp;</strong> &nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:<br />\n&nbsp; &nbsp; &nbsp; </strong>None</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"5977558","datemodified":"2021-08-16T12:05:33","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK3-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK3-2.1/CP049286.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK3-2.1/TACM6ALLGPK3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK3-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049286.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049286.scexe"],"md5sum":"2410587991c6dc11a56f0381007dde83","name":"firmware-hdd-3815d4b024-GPK3-2.1.x86_64.rpm","release":"2021-08-16T11:53:06","revision":"0","sha1sum":"8674febaf3f4895c9b1c253d00f41a5ca399e41a","size":"5MB","target_guids":["002340a5-434b-364d-5856-554c38303047","002340a5-434b-364d-5856-554c31543630","002340a5-434b-364d-5856-554c33543230","002340a5-434b-364d-5856-554c36543430","002340a5-434b-364d-5852-554c39363047","002340a5-434b-364d-5852-554c31543932","002340a5-434b-364d-5852-554c33543834","002340a5-434b-364d-5852-554c37543638"],"type_of_change":"1","version":"GPK3"}],"id":{"product":"990fcc25e986467fbdc6e3aae2e41a2c","version":"fd7335e522f94f0aa6eedd8727c0a8b3"},"installation":{"command":"CP043037.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p><strong>Additional Information:</strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p><strong>追加情報:</strong></p>\n\n<p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/jp/servers/spp_dl\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68 Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - KCM6XVUL800G、KCM6XVUL1T60、KCM6XVUL3T20、KCM6XVUL6T40、KCM6XRUL960G、KCM6XRUL1T92、KCM6XRUL3T84、KCM6XRUL7T68ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"KCM6XRUL960G","target_guid":"002340a5-434b-364d-5852-554c39363047","type":"nvme"},{"id":"KCM6XRUL7T68","target_guid":"002340a5-434b-364d-5852-554c37543638","type":"nvme"},{"id":"KCM6XRUL1T92","target_guid":"002340a5-434b-364d-5852-554c31543932","type":"nvme"},{"id":"KCM6XVUL3T20","target_guid":"002340a5-434b-364d-5856-554c33543230","type":"nvme"},{"id":"KCM6XRUL3T84","target_guid":"002340a5-434b-364d-5852-554c33543834","type":"nvme"},{"id":"KCM6XVUL800G","target_guid":"002340a5-434b-364d-5856-554c38303047","type":"nvme"},{"id":"KCM6XVUL6T40","target_guid":"002340a5-434b-364d-5856-554c36543430","type":"nvme"},{"id":"KCM6XVUL1T60","target_guid":"002340a5-434b-364d-5856-554c31543630","type":"nvme"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-16T11:38:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This Firmware release address below&nbsp;fixes and additional features:</p>\n\n<ul>\n\t<li>FW Transfer Fix</li>\n\t<li>Drive Failure Fix</li>\n\t<li>Power Loss Protection</li>\n\t<li>FW Download Fix</li>\n\t<li>Reset Fix</li>\n\t<li>Shutdown fix</li>\n\t<li>PCIe Improvement</li>\n\t<li>Random Write Improvement</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"KCM6XVUL6T40","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCM6XRUL1T92","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCM6XVUL800G","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCM6XVUL3T20","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCM6XRUL3T84","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCM6XVUL1T60","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCM6XRUL960G","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCM6XRUL7T68","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JWZHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a575a4841","Version":"HPD2"},{"DeviceName":"MB012000JWZHB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a575a4842","Version":"HPD2"},{"DeviceName":"MB014000JWZHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a575a4843","Version":"HPD2"},{"DeviceName":"MB016000JWZHE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a575a4845","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5967239","datemodified":"2021-07-23T10:38:35","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD2-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD2-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD2-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD2-2.1/CP049053.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD2-2.1/SHPEEVANSSD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD2-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD2-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD2-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD2-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049053.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049053.scexe"],"md5sum":"556eeb06ce3a2fa391fbe518fc43f4d1","name":"firmware-hdd-cf0b6cabe1-HPD2-2.1.x86_64.rpm","release":"2021-07-23T10:23:06","revision":"0","sha1sum":"8367f279ba1a15753cd193f5309e621b2612a1f6","size":"5MB","target_guids":["4d2340a5-3042-3031-3030-304a575a4841","4d2340a5-3042-3231-3030-304a575a4842","4d2340a5-3042-3431-3030-304a575a4843","4d2340a5-3042-3631-3030-304a575a4845"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"fa3afb08b69b4eb3ac32d9088c68d3a9","version":"23a30a4309a446afa2a21be95349bbd9"},"installation":{"command":"CP040294.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB010000JWZHA","target_guid":"4d2340a5-3042-3031-3030-304a575a4841","type":"sas"},{"id":"MB016000JWZHE","target_guid":"4d2340a5-3042-3631-3030-304a575a4845","type":"sas"},{"id":"MB014000JWZHC","target_guid":"4d2340a5-3042-3431-3030-304a575a4843","type":"sas"},{"id":"MB012000JWZHB","target_guid":"4d2340a5-3042-3231-3030-304a575a4842","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-20T10:35:23","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB010000JWZHA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB016000JWZHE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB012000JWZHB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB014000JWZHC","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG0600JEMCV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3630-304a454d4356","Version":"HPD6"},{"DeviceName":"EG1200JEMDA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3230-304a454d4441","Version":"HPD6"},{"DeviceName":"EG0300JFCKA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3330-304a46434b41","Version":"HPD6"},{"DeviceName":"EG0900JFCKB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3930-304a46434b42","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EG0300JFCKA, EG0600JEMCV, EG0900JFCKB, and EG1200JEMDA"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。 EG0300JFCKA、EG0600JEMCV、EG0900JFCKB、およびEG1200JEMDA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG0300JFCKA, EG0600JEMCV, EG0900JFCKB&nbsp;and EG1200JEMDA Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"17499607","datemodified":"2021-08-30T05:23:57","file_list":["/CP048263_BUILD_6.data","/CP048263.vmexe","/CP048263.vmexe64","/CP048263.vmfile","/CP048263_VMw.zip","/CP048263.xml","/payload.json","/CP048263_VMw.zip/index.xml","/CP048263_VMw.zip/vendor-index.xml","/CP048263_VMw.zip/metadata.zip","/CP048263_VMw.zip/vib20/CP048263/HPE_bootbank_CP048263_HPD6.6-7.0.0.15843807.vib","/CP048263_VMw.zip/metadata.zip/vendor-index.xml","/CP048263_VMw.zip/metadata.zip/vmware.xml","/CP048263_VMw.zip/metadata.zip/vibs/CP048263-3930429380519207185.xml","/CP048263_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048263_HPD6.6-7.0.0.15843807.xml"],"md5sum":"4e3fad9e60a56757fd27b304161773a8","name":"CP048263.zip","release":"2021-08-30T05:19:33","revision":"0","sha1sum":"2e55bd3df918d2f1bcc078e0320ed8a9eadd1775","size":"16MB","target_guids":["002340a5-4500-3047-3630-304a454d4356","002340a5-4500-3147-3230-304a454d4441","002340a5-4500-3047-3330-304a46434b41","002340a5-4500-3047-3930-304a46434b42"],"type_of_change":"1","version":"HPD6","vib_list":[{"name":"CP048263","version":"HPD6.6-7.0.0.15843807"}]}],"id":{"product":"f47f99ce0a3d4f73a3af884b56c63c54","version":"f7b3de47009f436e824f98a1f43b61d1"},"installation":{"command":"CP042546.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EG0300JFCKA, EG0600JEMCV, EG0900JFCKB and EG1200JEMDA Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EG0300JFCKA、EG0600JEMCV、EG0900JFCKB、およびEG1200JEMDAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG1200JEMDA","target_guid":"002340a5-4500-3147-3230-304a454d4441","type":"sas"},{"id":"EG0300JFCKA","target_guid":"002340a5-4500-3047-3330-304a46434b41","type":"sas"},{"id":"EG0600JEMCV","target_guid":"002340a5-4500-3047-3630-304a454d4356","type":"sas"},{"id":"EG0900JFCKB","target_guid":"002340a5-4500-3047-3930-304a46434b42","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-02T10:27:10","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG1200JEMDA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0600JEMCV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0900JFCKB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0300JFCKA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The Smart Storage Administrator (SSA) is a web-based application that helps you configure, manage, diagnose, and monitor Smart Array and SmartRAID Controllers and now other storage devices as well, such as host bus adapters (HBAs), Storage controllers, and future devices such as SCSI Express drives, and SAS switch devices."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p>Users will automatically be logged out after a predetermined period of inactivity when using&nbsp;SSA&nbsp;and will have to re-login.</p>\n\n<p>On the Web-based Management Device Homepage, under &quot;options&quot;, &quot;Anonymous Access&quot; should be enabled when using SSA.</p>\n\n<p>When clicking on a controller that is currently being configured in a different&nbsp;SSA&nbsp;session, a message will appear which allows you to override the other&nbsp;SSA&nbsp;session or cancel. If you choose to override the other&nbsp;SSA&nbsp;session, any unsaved changes in the other session will be discarded.</p>\n\n<p>To uninstall SSA, use Add/Remove Programs located in the Control Panel on Windows Systems.</p>\n\n<p>To run&nbsp;SSA&nbsp;in local application mode on Windows, Internet Explorer must be the default browser.</p>\n\n<p><strong>The following are known issues:</strong></p>\n\n<ul>\n\t<li>Sometimes the login on the Device Home Page will not work the first time. Click on the Device Home Page link again or refresh the page and re-login.</li>\n</ul>\n"}],"files":[{"bytes":"9876096","datemodified":"2021-08-11T12:03:49","file_list":["cp047062.xml","cpqsetup.exe","genericmsi.dll","SSA52080_X64.msi"],"md5sum":"eb653dd84e034eed4a9d5e66b34db1e9","name":"cp047062.exe","release":"2021-08-11T12:02:04","revision":"0","sha1sum":"d56eb2bf778f6515640ca7d02cde31c31b154677","size":"9MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecc02887d0"],"type_of_change":"1","version":"5.20.8.0"}],"id":{"product":"594618f566cc4fbca055e8866278e53d","version":"30e7e2f25b5e4076a7e7417929157f44"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number. \n<P>From that drive and directory, execute the downloaded file. \n<P>Click the \"Install\" button to proceed with the installation. The utility will automatically be installed.</P>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Smart Storage Administrator (SSA) for Windows 64-bit"},{"lang":"cn","x_late":"64位Windows版Smart Storage Administrator (SSA)"},{"lang":"ja","x_late":"Smart Storage Administrator (SSA) for Windows 64ビット"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-09T05:02:16","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added&nbsp;support&nbsp;to the HPE&nbsp;SR932i-p and SR416-a&nbsp;Gen10+&nbsp;Controllers.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2022 for HPE ProLiant Gen10 and Gen10 Plus platforms only.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U38","value":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"key":"U38","value":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"key":"","value":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U14","value":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4520 Gen9 Chassis</p>\n"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U27","value":"HPE ProLiant XL2x260w Gen9 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>\n"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"","value":"HPE ProLiant ML150 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"","value":"HPE ProLiant XL770f Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"Carbondale14","value":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"ssa.exe","sw_key_expectedpath":"%ProgramFiles%\\Smart Storage Administrator\\ssa\\bin"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel and Blade Storage Mezzanine Fibre Channel over Ethernet Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"3326240","datemodified":"2021-08-27T06:10:56","file_list":["./etc/depmod.d/brcmfcoe.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/brcmfcoe","./lib/modules/3.10.0-1160.el7.x86_64/extra/brcmfcoe/brcmfcoe.ko","./usr/share/smartupdate/kmod-brcmfcoe/component.xml"],"md5sum":"89926aa8b8ad91dd3f7cc8ca61d8a634","name":"kmod-brcmfcoe-12.0.1342.0-1.rhel7u9.x86_64.rpm","release":"2021-08-27T06:01:06","revision":"0","sha1sum":"b1c0638e7b641c59fee543a039ce5678c537cb4e","size":"3MB","target_guids":[],"type_of_change":"1","version":"12.0.1342.0"}],"id":{"product":"ffc1f93d83b148338fd005097b840f30","version":"7081f4ce794b4aa19f3c7d93317e8a45"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh brcmfcoe-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh brcmfcoe-kmp-default-11.2.xxxx.x_3.0.76._0.11-1.sles11sp3.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e brcmfcoe-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Red Hat Enterprise Linux 7 Update 9 Server Fibre Channel over Ethernet (FCoE) Driver Kit for HPE Storage Emulex(BRCM) Converged Network Adapters and mezzanine Converged Network Adapters(CNAs)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T11:00:41","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to Driver version 12.0.1342.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"}],"sw_keys":[{"name":"kmod-brcmfcoe","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GVYYU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMPN6TG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304756595955","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB6000GVYYU"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB6000GVYYU Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3420176","datemodified":"2021-07-25T15:24:12","file_list":["cp048612.xml","cpqsetup.exe","payload.json","setup.dll","SMPN6TG2.rel"],"md5sum":"60bdb699138f4698820ba6ea7f3a2e46","name":"cp048612.exe","release":"2021-07-25T15:17:05","revision":"0","sha1sum":"ccb32bf1447365d9897e18a70ca5384316ec2d7f","size":"3MB","target_guids":["002340a5-4d00-3642-3030-304756595955"],"type_of_change":"1","version":"HPG2"}],"id":{"product":"f620be56e3714dd58684aa99e9723c4b","version":"ff00e929cc4a462bb3b6b71e041e573b"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"text-decoration-line: none; color: blue;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB6000GVYYU Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB6000GVYYUドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB6000GVYYU","target_guid":"002340a5-4d00-3642-3030-304756595955","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T11:39:58","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000GVYYU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900217","languages":[{"lang":"fr","x_late":"Micrologiciel - Infrastructure Blade"},{"lang":"en","x_late":"Firmware - Blade Infrastructure"},{"lang":"cn","x_late":"固件 - 刀片式架构"},{"lang":"tw","x_late":"韌體 ─ 刀鋒型基礎架構"},{"lang":"de","x_late":"Firmware - Blade-Infrastruktur"},{"lang":"ko","x_late":"펌웨어 - 블레이드 인프라"},{"lang":"it","x_late":"Firmware - Infrastruttura Blade"},{"lang":"ja","x_late":"ファームウェア - ブレード インフラストラクチャ"},{"lang":"es","x_late":"Firmware - Infraestructura Blade"}]}],"description":[{"lang":"tw","x_late":"此元件包含 HPE BladeSystem c-Class Onboard Administrator 的韌體映像。此韌體提供 HPE BladeSystem c-Class Enclosure 的管理功能。此元件及其韌體可用於下列情況： 1) 作為可以為 Onboard Administrator 韌體的部署而編寫指令碼的獨立元件，2) 在和可以在 Smart Update 韌體 DVD 上找到的 HP Smart Update Manager 一起使用時，此元件可以用於部署韌體至 HP BladeSystem c-Class Onboard Administrator，以及 3) 從該元件解壓縮的韌體可使用 HP BladeSystem c-Class Onboard Administrator 的網路型使用者介面來部署。"},{"lang":"en","x_late":"This component contains the firmware image for HPE BladeSystem c-Class Onboard Administrator. This firmware provides management capabilities for the HPE BladeSystem c-Class Enclosure. This component and its firmware can be used in the following scenarios: 1) as a stand alone component that can be used to script the deployment of the Onboard Administrator firmware, 2) in conjunction with the HPE Smart Update Manager found on the Smart Update Firmware DVD, the component can be used to deploy the firmware to the HPE BladeSystem c-Class Onboard Administrator, and 3) firmware extracted from the component can be deployed using the web-based user interface for the HPE BladeSystem c-Class Onboard Administrator."},{"lang":"ko","x_late":"이 구성 요소에는 HPE BladeSystem c-Class Onboard Administrator의 펌웨어 이미지가 포함되어 있습니다. 이 펌웨어는 HPE BladeSystem c-Class Enclosure에 대한 관리 기능을 제공합니다. 해당 구성요소와 펌웨어는 다음과 같은 상황에서 사용할 수 있습니다. 1) 독립형 구성 요소로서 Onboard Administrator 펌웨어의 배포 스크립트에 사용될 수 있습니다 2) 스마트 업데이트 펌웨어 DVD에 포함되어 있는 HP Smart Update Manager와 함께 구성요소를 사용하여 HP BladeSystem c-Class Onboard Administrator로 펌웨어를 배포할 수 있습니다 3) HP BladeSystem c-Class Onboard Administrator용 웹 기반 사용자 인터페이스를 사용하여 구성 요소에서 추출된 펌웨어를 배포할 수 있습니다."},{"lang":"cn","x_late":"该组件包含适用于 HPE BladeSystem c-Class Onboard Administrator 的固件映像。该固件可为 HPE BladeSystem c-Class 机箱提供管理功能。该组件及其固件适用于以下情形： 1) 作为可用于编写 Onboard Administrator 固件的部署脚本的独立组件，2) 与 HPE Smart Update Firmware DVD 中的 HP Smart Update Manager 共同使用，此组件可用于将固件部署至 HPE BladeSystem c-Class Onboard Administrator，以及 3) 可使用 HPE BladeSystem c-Class Onboard Administrator 的基于 WEB 的用户界面来部署从该组件中提取的固件。"},{"lang":"ja","x_late":"このコンポーネントには、HPE BladeSystem c-Class Onboard Administratorのファームウェアイメージが含まれています。このファームウェアは、HPE BladeSystem c-Classエンクロージャーの管理機能を提供します。このコンポーネントおよびファームウェアは、以下のような場合に使用してください。1) Onboard Administratorファームウェアの展開を記述するために使用するスタンドアロンのコンポーネント 2) HPE BladeSystem c-Class Onboard Administratorにファームウェアをインストールするために、Smart Update Firmware DVD上のHPE Smart Update Managerと共同でコンポーネントを使用する 3) コンポーネントから展開したファームウェアをHPE BladeSystem c-Class Onboard AdministratorのWebベースユーザーインターフェイスを使用してインストールする"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name</strong></p>\n\n<p>HPE BladeSystem c-Class OA Firmware</p>\n\n<p><strong>Release Version</strong></p>\n\n<p>Version 4.97</p>\n\n<p><strong>Previous Version of Firmware</strong></p>\n\n<p>Version 4.96</p>\n\n<p><strong>Firmware Dependency</strong></p>\n\n<p>For firmware compatibility information,see the&nbsp;<em>HPE Service Pack for ProLiant Information Library</em>at:<br />\n<a href=\"https://www.hpe.com/servers/spp/documentation\">https://www.hpe.com/servers/spp/documentation</a></p>\n\n<p><strong>Important Notes</strong></p>\n\n<ul>\n\t<li><strong>Firmware Upgrade</strong></li>\n</ul>\n\n<p>Starting OA 4.50 release, a standardized code signing and validation mechanism has been introduced to enhance the firmware image authenticity.</p>\n\n<p>For customers using Firmware ROM image to upgrade OA:</p>\n\n<p>For OA with firmware version less than 3.50, first update to OA 3.50 and then continue updating to OA 4.50 or above.</p>\n\n<p>For customers using Smart Components to upgrade OA:</p>\n\n<p>OA firmware update mechanisms which rely on HPE Smart Components (example: EFM), will not be affected by this change. The Smart Component will automatically perform the intermediate upgrade to OA 3.50 before performing the OA 4.50 or above upgrade.</p>\n\n<ul>\n\t<li><strong>Flash Disaster Recovery</strong></li>\n</ul>\n\n<p>Flash Disaster Recovery to a version of firmware 4.50 or above issupported. The behavior is seen due to the implementation of a new firmware image signing mechanism in OA firmware version 4.50 and above, which causes the FDR mechanism to see the firmware image as an invalid image.</p>\n\n<p>The workaround for this is to use Flash Disaster Recovery procedure to recover to a version of firmware prior to 4.50 and then do a firmware upgrade to the intended version (4.50 or later).</p>\n\n<ul>\n\t<li><strong>EFM</strong></li>\n</ul>\n\n<p>The OA only supports SPP ISO images that are less than 4GB in size, whether hosted directly via the Enclosure DVD feature or an attached USB key, or mounted remotely via a specified URL. If an ISO image exceeds 4 GB, the CLI SHOW FIRMWARE MANAGEMENT command displays ISO URL Status as &ldquo;Invalid URL.&rdquo;<br />\n<br />\nIf an SPP ISO image exceeds 4 GB, it is necessary to create a custom ISO image that excludes components unnecessary to the OA EFM blade firmware update process.&nbsp; At a minimum, the custom ISO must contain the firmware components for HPE ProLiant BL servers. (When using HPE SUM to create the custom ISO image, select Firmware as the Component Type, and select HPE ProLiant BL Series as the Server Type.)&nbsp; For information about creating a custom ISO image compatible for OA EFM functionality, see the&nbsp;<em>HPE BladeSystem Onboard Administrator User Guide</em>. More HPE SUM information can be found via HPE Smart Update Manager online help or at the HPE Smart Update Enterprise Information Library (<a href=\"http://www.hpe.com/info/hpsum/documentation\">http://www.hpe.com/info/hpsum/documentation</a>).</p>\n\n<ul>\n\t<li><strong>FIPS</strong></li>\n</ul>\n\n<p>Onboard Administrator 4.71 is FIPS certified as referenced in the 140-2 In Process list located at <a href=\"http://csrc.nist.gov/groups/STM/cmvp/documents/140-1/140InProcess.pdf\">http://csrc.nist.gov/groups/STM/cmvp/documents/140-1/140InProcess.pdf</a>.</p>\n\n<ul>\n\t<li><strong>IPv6</strong></li>\n</ul>\n\n<p>When the Enable DHCPv6, Enable Router Advertisements, or Enable SLAAC enclosure IPv6 settings are disabled on the Onboard Administrator, the respective DHCPv6 or SLAAC addresses of the iLOs in the enclosure are retained until these addresses expire automatically based on their respective configurations.&nbsp; A manual reset of the iLO releases these addresses immediately.</p>\n"}],"files":[{"bytes":"34466461","datemodified":"2021-01-28T15:10:57","file_list":["./usr/lib/x86_64-linux-gnu/firmware-oa-4.97-1.1","./usr/lib/x86_64-linux-gnu/firmware-oa-4.97-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-oa-4.97-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-oa-4.97-1.1/CP046216.xml","./usr/lib/x86_64-linux-gnu/firmware-oa-4.97-1.1/archives","./usr/lib/x86_64-linux-gnu/firmware-oa-4.97-1.1/archives/hpoa350.bin","./usr/lib/x86_64-linux-gnu/firmware-oa-4.97-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-oa-4.97-1.1/oa497.bin","./usr/lib/x86_64-linux-gnu/firmware-oa-4.97-1.1/oaupgrade32","./usr/lib/x86_64-linux-gnu/firmware-oa-4.97-1.1/oaupgrade64","./usr/lib/x86_64-linux-gnu/firmware-oa-4.97-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046216.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046216.scexe"],"md5sum":"7e9e77475f20a1849957d8e789fd5135","name":"firmware-oa-4.97-1.1.x86_64.rpm","release":"2021-01-28T14:59:07","revision":"0","sha1sum":"faa394574186f2d488dd1b78b4caf4174486511d","size":"32MB","target_guids":[],"type_of_change":"1","version":"4.97"}],"id":{"product":"C9506","version":"71201b28c2ee415cb2442224c541abea"},"installation":{"command":"oaupgrade","command_params":"oa497.bin","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":500,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>This component and its firmware can be used in the following scenarios:</strong></p>\n\n<ol>\n\t<li>As a standalone component that can be used to script the deployment of the Onboard Administrator firmware</li>\n\t<li>In conjunction with the HPE Smart Update Manager found on HPE Service Pack for ProLiant (SPP), the component can be used to deploy the firmware to the HPE BladeSystem c-Class Onboard Administrator</li>\n\t<li>Firmware extracted from the component can be deployed using the web-based user interface for the HPE BladeSystem c-Class Onboard Administrator</li>\n</ol>\n\n<p><strong>Installation Notes for using the component as a standalone component</strong></p>\n\n<p>This SCEXE component is a self-extracting executable. The SCEXE file unpacks itself, flashes the firmware on the HPE BladeSystem c-Class Onboard Administrator, and cleans up.<br />\n<br />\nThe general command line syntax for this smart component is</p>\n\n<p>sh cpxxxxxx.scexe -target &lt;netAddress&gt; -user &lt;username&gt; -passwd &lt;password&gt; [-s[ilent]] [-f[orce]] [-logdir &lt;path&gt;]</p>\n\n<p>where cpxxxxxx.scexe represents the filename of the component</p>\n\n<p>NOTE: All arguments and information enclosed in brackets are optional. If required arguments are not included on the command line, you will be prompted to provide the input.</p>\n\n<ul>\n\t<li>-target &lt;netAddress&gt;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;The netAddress parameter is the IP address or DNS name of the OA to target. This should be the Active OA if two OA&rsquo;s are in an enclosure. There is a space between the -target and the netAddress parameter.</li>\n\t<li>-user &lt;username&gt;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; The username is the userid to use when attempting to login to the OA. There is a space between the -user and the username parameter.</li>\n\t<li>-passwd &lt;password&gt;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;The password is the password for the userid to login to the OA. There is a space between the -passwd and the password parameter.</li>\n\t<li>-s[ilent]&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; The silent option will silently install the firmware, if needed.</li>\n\t<li>-f[orce]&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;The force option will cause the OA Flash utility to either downgrade the existing firmware or reinstall the same version of firmware on the target OA.</li>\n\t<li>-logdir &lt;path&gt;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp; &nbsp;&nbsp; &nbsp;&nbsp;&nbsp;This optional parameter is used to redirect the output from the OA flash utility to a different directory than the default location of /var/hp/log/&lt;netAddress&gt;. The redirected location is &lt;path&gt;/hp/log/&lt;netAddress&gt;.</li>\n</ul>\n\n<p>To flash the firmware:</p>\n\n<ul>\n\t<li>Download the SCEXE file to a server which is on the same network as the HPE BladeSystem c-Class Onboard Administrator to be updated.</li>\n\t<li>Execute sh cpxxxxxx.scexe -target &lt;netAddress&gt; -user &lt;username&gt; -passwd &lt;password&gt; [-s[ilent]] [-f[orce]] [-logdir &lt;path&gt;]</li>\n</ul>\n\n<p>The return codes are:</p>\n\n<ul>\n\t<li>0 Success</li>\n\t<li>1 Reserved</li>\n\t<li>2 Upgrade is not needed because firmware version is current</li>\n\t<li>3 Upgrade is not needed because newer firmware version is present</li>\n\t<li>4 Target not found</li>\n\t<li>5 User terminated session</li>\n\t<li>6 Incorrect parameter</li>\n\t<li>7 General failure</li>\n</ul>\n\n<p><strong>Installation Notes for using the component with HPE Smart Update Manager and the SPP</strong></p>\n\n<ol>\n\t<li>Obtain the latest version of the SPP.</li>\n\t<li>Place the SPP on a USB key using the&nbsp;<a href=\"https://h20565.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_357c87ee9b054ad7a631d9eaba&amp;sp4ts.oid=8788686\">HPE USB Key Utility</a>.</li>\n\t<li>Place this component in the directory, /packages on the USB key.</li>\n\t<li>Place the USB key in a system which is on the same network as the Onboard Administrator to be updated.</li>\n\t<li>Launch hpsum from /packages.</li>\n\t<li>Follow the GUI to install the firmware on the Onboard Adminstrator.</li>\n</ol>\n\n<p><strong>Installation Notes for using the firmware extracted from the component</strong></p>\n\n<ol>\n\t<li>Extract the firmware binary out of the component.</li>\n\t<li>Place the firmware image file onto a system on the same network as the HPE BladeSystem c-Class Onboard Administrator.</li>\n\t<li>Log in to the Onboard Administrator&#39;s web-based user interface as an administrator. Firmware Update is available under the Active Onboard Administrator category. You may select the firmware image by entering a path to the file in the &quot;Local File&quot; field or by clicking on the &quot;Browse&quot; button to locate the firmware image on the local machine, a mapped drive, or a network share.</li>\n\t<li>Click &quot;Upload&quot; to begin the firmware update process.</li>\n</ol>\n\n<p>The user guide for the Onboard Administrator is located&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=c00705292\">here</a>.<br />\nThe user guide for the Onboard Administrator command line interface is located&nbsp;<a href=\"http://h20565.www2.hpe.com/hpsc/doc/public/display?sp4ts.oid=3188465&amp;docId=emr_na-c00702815&amp;docLocale=en_US\">here</a>.</p>\n"},{"lang":"ja","x_late":"<p><strong>このコンポーネントとその中のファームウェアは、次のシナリオで使用することができます:</strong></p>\n\n<ol>\n\t<li>Onboard Administratorファームウェアの展開を記述するために使用するスタンドアロンのコンポーネント</li>\n\t<li>HPE BladeSystem c-Class Onboard Administratorにファームウェアをインストールするために、HP Service Pack for ProLiant（SPP）上のHP Smart Update Managerと共同でコンポーネントを使用することができます。</li>\n\t<li>コンポーネントから展開したファームウェアをHPE BladeSystem c-Class Onboard AdministratorのWebベースユーザーインターフェイスを使用して展開することができます。</li>\n</ol>\n\n<p><strong>コンポーネントをスタンドアロンコンポーネントで使用する場合のインストール時の注意</strong></p>\n\n<p>このSCEXEコンポーネントは、自己解凍型実行可能ファイルです。SCEXEファイルは、ファイル自身を解凍し、HPE BladeSystem c-Class Onboard Administratorのファームウェアをフラッシュした後、解凍したファイルを削除します。<br />\n<br />\nこのSmartコンポーネントの一般的なコマンドラインの文法は、以下のとおりです。</p>\n\n<p>sh cpxxxxxx.scexe -target <netAddress> -user <username> -passwd <password> [-s[ilent]] [-f[orce]] [-logdir <path>]</p>\n\n<p>cpxxxxxx.scexeは、コンポーネントのファイル名を意味します</p>\n\n<p>注記：鍵括弧でくくられたすべての引数および情報は、任意です。必要な引数がコマンドラインに含まれていない場合は、入力するようにプロンプトが表示されます。</p>\n\n<ul>\n\t<li>-target <netAddress>          netAddressパラメーターは、ターゲットへのOAのIPアドレスまたはDNS名です。1つのエンクロージャーに2つのOAが存在する場合は、アクティブなOAを指定する必要があります。-targetとnetAddressパラメーターの間にはスペースが必要です。</li>\n\t<li>-user <username>              ユーザー名はOAにログインするときに使用するユーザーIDです。-userとusernameパラメーターの間にはスペースが必要です。</li>\n\t<li>-passwd <password>           パスワードは、OAにログインするためのユーザーIDに対応するパスワードです。-passwdとpasswordパラメーターの間にはスペースが必要です。</li>\n\t<li>-s[ilent]                               サイレントオプションは、必要な場合ファームウェアを静かにインストールします。</li>\n\t<li>-f[orce]                               forceオプションは、OAフラッシュユーティリティがターゲットOAに既存のファームウェアをダウングレード、または同じバージョンのファームウェアを再インストールするために使用します。</li>\n\t<li>-logdir <path>                     このオプションパラメーターは、OAフラッシュユーティリティからの出力をデフォルトの場所/var/hp/log/<netAddress>ではなく、別のディレクトリにリダイレクトするために使用します。リダイレクトされる場所は、<path>/hp/log/<netAddress>です。</li>\n</ul>\n\n<p>ファームウェアをフラッシュするには、以下の手順に従ってください。</p>\n\n<ul>\n\t<li>アップデートするHPE BladeSystem c-Class Onboard Administratorと同じネットワーク上のサーバーにSCEXEファイルをダウンロードします。</li>\n\t<li>Execute sh cpxxxxxx.scexe -target <netAddress> -user <username> -passwd <password> [-s[ilent]] [-f[orce]] [-logdir <path>]</li>\n</ul>\n\n<p>リターンコードは、以下のとおりです。</p>\n\n<ul>\n\t<li>0 成功</li>\n\t<li>1 予約済み</li>\n\t<li>2 ファームウェアのバージョンが同一のためアップグレードの必要がない</li>\n\t<li>3  新しいバージョンのファームウェアがインストールされているためアップグレードの必要がない</li>\n\t<li>4  ターゲットが見つからない</li>\n\t<li>5 ユーザーによって中止された</li>\n\t<li>6 パラメーターが不正</li>\n\t<li>7 通常の障害</li>\n</ul>\n\n<p><strong>HPE Smart Update ManagerおよびSPPとコンポーネントを使用する場合のインストール時の注意</strong></p>\n\n<ol>\n\t<li>SPPの最新バージョンを入手します。</li>\n\t<li><a href=\"https://h20565.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_357c87ee9b054ad7a631d9eaba&sp4ts.oid=8788686\">HPE USB Key Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>このコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>アップデートするOnboard Administratorと同じネットワーク上のシステムにUSBキーを接続します。</li>\n\t<li>/packagesからhpsumを起動します。</li>\n\t<li>GUIに従ってOnboard Administratorにファームウェアをインストールします。</li>\n</ol>\n\n<p><strong>コンポーネントから解凍したファームウェアを使用する場合のインストール時の注意</strong></p>\n\n<ol>\n\t<li>コンポーネントのファームウェアバイナリを展開します。</li>\n\t<li>HPE BladeSystem c-Class Onboard Administratorと同じネットワーク上のシステムにファームウェアイメージファイルをコピーします。</li>\n\t<li>Onboard AdministratorのWebベースユーザーインターフェイスに管理者でログインします。アクティブOnboard Administratorカテゴリからファームウェアのアップデートを行うことができます。［ローカルファイル］フィールドにファイルのパスを入力するか、［参照］ボタンを押してローカルマシン、割り当てられたドライブ、またはネットワーク共有から探してクリックして、ファームウェアイメージを選択します。</li>\n\t<li>［アップロード］をクリックして、ファームウェアアップデートを開始します。</li>\n</ol>\n\n<p>『Onboard Administratorユーザーガイド』は、<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&docId=c00705292\">こちら</a>にあります。<br />\n『Onboard Administratorコマンドラインインターフェイスユーザーガイド』は、<a href=\"http://h20565.www2.hpe.com/hpsc/doc/public/display?sp4ts.oid=3188465&docId=emr_na-c00702815&docLocale=en_US\">こちら</a>にあります。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Linux 的線上 HPE BladeSystem c-Class Onboard Administrator 韌體元件"},{"lang":"en","x_late":"Online HPE BladeSystem c-Class Onboard Administrator Firmware Component for Linux"},{"lang":"ko","x_late":"Linux용 온라인 HPE 블레이드 시스템 c-클래스 Onboard Administrator 펌웨어 구성 요소"},{"lang":"cn","x_late":"用于 Linux 的联机 HPE BladeSystem c 类板载管理员固件组件"},{"lang":"ja","x_late":"オンラインHPE BladeSystem c-Class Onboard Administratorファームウェアコンポーネント for Linux"}],"prerequisites":{"required_diskspace":{"size_kb":"10000"},"supported_devices":[{"id":"403318-B21 ","target_guid":"","type":"other"},{"id":"437502-B21","target_guid":"","type":"other"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-03T12:17:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Onboard Administrator 4.96&nbsp;provides support for the following enhancements:</p>\n\n<p><strong>Hardware additions</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p>Features<strong>: additions and changes</strong></p>\n\n<p><strong>General</strong></p>\n\n<ul>\n\t<li>AlertMail feature now supports two priorities that a user can select for the AlertMail messages..</li>\n\t<li>Enclosure Firmware Management (EFM) feature is optimized to speed up the EFM update operation.</li>\n\t<li>The SSL certificate of Onboard Administrator now supports Fully Qualified Domain Name (FQDN) in <strong>Common Name (CN) field and IP address in <strong>SAN </strong>field.</strong></li>\n\t<li>Common Access Card (CAC) Authentication feature is enhanced to support a configurable timeout for the SSL session.</li>\n</ul>\n\n<p><strong>&nbsp;Security</strong></p>\n\n<ul>\n\t<li>Onboard Administrator supports two new TLS_DHE_RSA ciphers</li>\n\t<li>FIPS TOP-SECRET mode ciphers are now supported in FIPS <strong>ON </strong>and <strong>OFF </strong>modes.</li>\n\t<li>CLI commands SHOW SSH CIPHER, ENABLE SSH CIPHER and DISABLE SSH CIPHER are added to Show, Enable and Disable SSH ciphers in FIPS ON and OFF modes.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>General</strong></p>\n\n<ul>\n\t<li>Addressed an issue where SNMP queries to Onboard Administrator OIDs were not successfully completed when VLAN is configured for Blades and Interconnects.</li>\n\t<li>Addressed an issue in the Device and Rack Summary GUI page to eliminate the duplicate display of FLB and Mezz adapters information.</li>\n\t<li>Addressed an issue where Interconnects were not receiving IP address from EBIPA (or) external DHCP server.</li>\n\t<li>Addressed an issue where Blade Location information was not displayed correctly in SHOW SERVER STATUS ALL CLI command.</li>\n\t<li>Addressed an issue where DNS record update was getting delayed in DNS server when a user configured a domain name in Onboard Administrator.</li>\n</ul>\n\n<p><strong>Security</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Issues and workarounds</strong></p>\n\n<p><strong>Browsers</strong></p>\n\n<ul>\n\t<li>OA GUI is not accessible in Chrome versions 43.0.2357.10 to 44.0.2383.The issue was caused by a &ldquo;regression&rdquo; in Chrome (or WebKit). Customers should use an alternative browser like Firefox or Internet Explorer or try a different version of Chrome.</li>\n\t<li>SSO-to-iLO connection from the OA using an iLO host name fails with Microsoft Internet Explorer11 on Windows 8. On a Windows 8 system with Internet Explorer 10 or Internet Explorer 11, if the OA web GUI session is loaded using a host name instead of an IP address, an attempt to open an iLO window using SSO from the OA web GUI might result in the iLO page loading in the OA web GUI window instead of the intended new window. This issue was determined to be a bug in Internet Explorer and is expected to be fixed in a future release or update for Internet Explorer. To work around this issue, either use an IP address to load the OA Web GUI, or turn off Protected Mode for the appropriate zone in Internet Explorer&rsquo;s settings. This issue occurs only on Internet Explorer browsers.</li>\n</ul>\n\n<p><strong>FIPS</strong></p>\n\n<p style=\"margin-left:40px\">Certificates smaller than 2048 bits in size are not compliant with FIPS requirements as enforced by the OA firmware starting with OA 4.20. When the OA running OA firmware version 4.40 or greater is operating in FIPS Mode ON/DEBUG and is configured with a 1024-bit LDAP certificate that was installed when running a previous version of OA firmware, FIPS Mode ON/DEBUG is considered to be operating in a degraded state due to the presence of the non-compliant certificate. While operating in this FIPS-Degraded Mode operational state, attempts to set FIPS Mode OFF from the OA GUI Network Access&gt;FIPS tab will fail and show the error message The selected FIPS mode is already enabled. When the non-compliant certificate is removed, the FIPS-Degraded operational status is cleared, FIPS Mode can then be successfully set to OFF from the GUI interface. Note that the OA CLI command SET FIPS MODE OFF can be successfully used to set FIPS Mode OFF even with non-compliant 1024-bit LDAP certificates installed in the OA.</p>\n\n<p><strong>IRC</strong></p>\n\n<p style=\"margin-left:40px\">Unable to open .net IRC console for Gen10 Blades, Gen9 Blades also have the same issue. The Java applet and Webstart however, loads but the virtual media mounting fails. The work around is to launch the IRC through IRC Application (HPE Lights-Out Stand Alone Remote Console) which is installed on terminal client.</p>\n\n<p><strong>EFM</strong></p>\n\n<p style=\"margin-left:40px\">To use EFM on Gen 10 Blades, please select options/filters &ldquo;<em>Make Bootable ISO file&rdquo; and&nbsp;</em>&ldquo;<em>Enclosure Firmware Management&rdquo;</em>&nbsp;while creating custom SPP ISO on HPE SUM 8.0.0. Please refer to HPE SUM 8.0.0 User guide for further details.</p>\n\n<p><strong>CAC</strong></p>\n\n<ul>\n\t<li>In the CAC mode SSH, Telnet and XML Reply protocols will be disabled.</li>\n\t<li>Linked enclosure login will not work if the linked enclosure in CAC mode.</li>\n\t<li>If accurate Service account details are not provided, LDAP user login with certificate will fail.</li>\n\t<li>It is highly recommended to establish a recovery plan before getting started with CAC.&nbsp; If something goes wrong with the OA configuration, the OA may be recovered through the serial port or Insight Display panel and USB KEY. Both methods require physical access to the OA.&nbsp; However, if an LCD PIN has been configured (and forgotten) and local accounts have been disabled or CAC has been incorrectly configured then, the only way to recover is through a serial port. The two most common situations where OA recovery is needed are when LDAP has been configured incorrectly with local accounts disabled or when CAC has been configured without certificate access.</li>\n</ul>\n\n<p><strong>Configurable SSH Port Number&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong></p>\n\n<p style=\"margin-left:0in; margin-right:0in\">If a Standby OA is running firmware version less than 4.85 and it is updated to firmware version greater than or equal to 4.85 using synchronize firmware feature from Active OA, after the firmware update and reboot of the Standby OA, SSH port will not open in the configured port number. The work around is to reboot the Standby OA and SSH port will open in the configured port in next boot. This issue will not occur in the case where SSH port is configured to default port 22 in the Active OA.</p>\n"},{"curr_enhancements_x_late":"<p>Onboard Administrator 4.97&nbsp;provides support for the following enhancements:</p>\n\n<p><strong>Hardware additions</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p>Features<strong>: additions and changes</strong></p>\n\n<p>&nbsp;</p>\n\n<p><strong>General</strong></p>\n\n<ul>\n\t<li>A new feature is added to SNMP to support enable/disable options for v1/v2c protocols.</li>\n\t<li>New SNMP traps were added for emergency brake (e-brake) activated and deactivated events.</li>\n\t<li>Added support for firmware update of new NIDEC fans.</li>\n\t<li>Enhanced PowerPIC firmware update to support firmware version 1.8.</li>\n\t<li>In the Onboard Administrator GUI added support for iLO HTML5 IRC console.</li>\n</ul>\n\n<p><strong>&nbsp;Security</strong></p>\n\n<ul>\n\t<li>A new feature is added in SSH to support enable/disable of Key Exchange (KEX) Algorithms.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>General</strong></p>\n\n<ul>\n\t<li>Addressed an issue where running concurrent UPDATE ILO cli command from different SSH sessions cause few of the commands to end in operation failure.</li>\n\t<li>Fixed an issue in SET SERVER DVD CONNECT cli command usage in IPv6 environment.</li>\n\t<li>Addressed an issue where blade&rsquo;s ProductID update in System Rom RBSU is not reflected in the Onboard Administrator.</li>\n\t<li>Harnessed certificate read operation from flash to minimize certificate read failures.</li>\n\t<li>Fixed an issue in SNMP v3 protocol where EngineTime was not reset on increment of EngineBoot count.</li>\n\t<li>Addressed an issue related to blade discovery failure</li>\n\t<li>Fixed an issue in Smart Component where it fails to establish communication with Onboard Administrator using DHE ciphers.</li>\n\t<li>Addressed an issue related to ECDSA ciphers enable/disable feature.</li>\n\t<li>Added SSH cipher list to the configuration script</li>\n\t<li>Fixed an issue in Onboard Administrator GUI where IPv4 DynamicDNS could not be enabled when enclosure is configured for static IP configuration.</li>\n\t<li>Fixed help message display issues in CLI commands SET SSL_SESSION TIMEOUT and SET SECURESH.</li>\n\t<li>Addressed an issue in SNMP where EngineBoot count was incremented by two for add/delete of trap receiver.</li>\n\t<li>Fixed Online Help (OLH) pages display issue that occur when language pack is uploaded into Onboard Administrator.</li>\n</ul>\n\n<p><strong>Security</strong></p>\n\n<p>&nbsp;</p>\n\n<p>The following security vulnerabilities are fixed:</p>\n\n<ul>\n\t<li>Onboard Administrator&rsquo;s web server response is enhanced to include X-Content-Type-Options security header.</li>\n\t<li>CVE-2011-3026 - libpng: Heap buffer overflow</li>\n\t<li>CVE-2018-1000517 - BusyBox wget version&nbsp; contains a Buffer Overflow vulnerability</li>\n\t<li>CVE-2020-1971 - EDIPARTYNAME NULL pointer de-reference</li>\n\t<li>CVE-2020-15861 - Net-SNMP allows Escalation of Privileges</li>\n\t<li>CVE-2020-15862 - Net-SNMP provides the ability to run arbitrary commands as root.</li>\n\t<li>CVE-2019-20892 &ndash; SNMPv3 get bulk request issue<br />\n\t&nbsp;</li>\n</ul>\n\n<p><strong>Issues and workarounds</strong></p>\n\n<p>&nbsp;</p>\n\n<p><strong>Browsers</strong></p>\n\n<ul>\n\t<li>OA GUI is not accessible in Chrome versions 43.0.2357.10 to 44.0.2383.The issue was caused by a &ldquo;regression&rdquo; in Chrome (or WebKit). Customers should use an alternative browser like Firefox or Internet Explorer or try a different version of Chrome.</li>\n\t<li>SSO-to-iLO connection from the OA using an iLO host name fails with Microsoft Internet Explorer11 on Windows 8. On a Windows 8 system with Internet Explorer 10 or Internet Explorer 11, if the OA web GUI session is loaded using a host name instead of an IP address, an attempt to open an iLO window using SSO from the OA web GUI might result in the iLO page loading in the OA web GUI window instead of the intended new window. This issue was determined to be a bug in Internet Explorer and is expected to be fixed in a future release or update for Internet Explorer. To work around this issue, either use an IP address to load the OA Web GUI, or turn off Protected Mode for the appropriate zone in Internet Explorer&rsquo;s settings. This issue occurs only on Internet Explorer browsers.</li>\n</ul>\n\n<p><strong>FIPS</strong></p>\n\n<p style=\"margin-left:40px\">Certificates smaller than 2048 bits in size are not compliant with FIPS requirements as enforced by the OA firmware starting with OA 4.20. When the OA running OA firmware version 4.40 or greater is operating in FIPS Mode ON/DEBUG and is configured with a 1024-bit LDAP certificate that was installed when running a previous version of OA firmware, FIPS Mode ON/DEBUG is considered to be operating in a degraded state due to the presence of the non-compliant certificate. While operating in this FIPS-Degraded Mode operational state, attempts to set FIPS Mode OFF from the OA GUI Network Access&gt;FIPS tab will fail and show the error message The selected FIPS mode is already enabled. When the non-compliant certificate is removed, the FIPS-Degraded operational status is cleared, FIPS Mode can then be successfully set to OFF from the GUI interface. Note that the OA CLI command SET FIPS MODE OFF can be successfully used to set FIPS Mode OFF even with non-compliant 1024-bit LDAP certificates installed in the OA.</p>\n\n<p><strong>IRC</strong></p>\n\n<p style=\"margin-left:40px\">Unable to open .net IRC console for Gen10 Blades, Gen9 Blades also have the same issue. The Java applet and Webstart however, loads but the virtual media mounting fails. The work around is to launch the IRC through IRC Application (HPE Lights-Out Stand Alone Remote Console) which is installed on terminal client.</p>\n\n<p><strong>EFM</strong></p>\n\n<p style=\"margin-left:40px\">To use EFM on Gen 10 Blades, please select options/filters &ldquo;<em>Make Bootable ISO file&rdquo; and&nbsp;</em>&ldquo;<em>Enclosure Firmware Management&rdquo;</em>&nbsp;while creating custom SPP ISO on HPE SUM 8.0.0. Please refer to HPE SUM 8.0.0 User guide for further details.</p>\n\n<p><strong>CAC</strong></p>\n\n<ul>\n\t<li>In the CAC mode SSH, Telnet and XML Reply protocols will be disabled.</li>\n\t<li>Linked enclosure login will not work if the linked enclosure in CAC mode.</li>\n\t<li>If accurate Service account details are not provided, LDAP user login with certificate will fail.</li>\n\t<li>It is highly recommended to establish a recovery plan before getting started with CAC.&nbsp; If something goes wrong with the OA configuration, the OA may be recovered through the serial port or Insight Display panel and USB KEY. Both methods require physical access to the OA.&nbsp; However, if an LCD PIN has been configured (and forgotten) and local accounts have been disabled or CAC has been incorrectly configured then, the only way to recover is through a serial port. The two most common situations where OA recovery is needed are when LDAP has been configured incorrectly with local accounts disabled or when CAC has been configured without certificate access.</li>\n</ul>\n\n<p><strong>Configurable SSH Port Number&nbsp;&nbsp;&nbsp;</strong></p>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong></p>\n\n<p style=\"margin-left:40px; margin-right:0in\">If a Standby OA is running firmware version less than 4.85 and it is updated to firmware version greater than or equal to 4.85 using synchronize firmware feature from Active OA, after the firmware update and reboot of the Standby OA, SSH port will not open in the configured port number. The work around is to reboot the Standby OA and SSH port will open in the configured port in next boot. This issue will not occur in the case where SSH port is configured to default port 22 in the Active OA.</p>\n\n<p style=\"margin-left:40px; margin-right:0in\">&nbsp;</p>\n\n<p><strong>Smart component</strong></p>\n\n<p>&nbsp;</p>\n\n<p style=\"margin-left:40px\">When OA is in FIPS ON or FIPS TOP-SECRET mode and any of the ciphers that use&nbsp;&nbsp;&nbsp;Diffie-Hellman (DH) keys are enabled, firmware upgrade or downgrade using OA Smart&nbsp;&nbsp;Component 4.96 or earlier versions may fail with following error:</p>\n\n<p style=\"margin-left:40px\">&nbsp;&nbsp; Error: 1013: Client cannot connect with the Onboard Administrator. Verify the target address is correct and can be accessed from your system.</p>\n\n<p>&nbsp;</p>\n\n<p style=\"margin-left:40px\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<p style=\"margin-left:80px\">FIPS ON</p>\n\n<p style=\"margin-left:80px\">TLS_DHE_RSA_WITH_3DES_EDE_CBC_SHA<br />\nTLS_DHE_RSA_WITH_AES_128_GCM_SHA25<br />\nTLS_DHE_RSA_WITH_AES_256_GCM_SHA384<br />\nTLS_DHE_RSA_WITH_AES_128_CBC_SHA256<br />\nTLS_DHE_RSA_WITH_AES_256_CBC_SHA256</p>\n\n<p style=\"margin-left:80px\">&nbsp;</p>\n\n<p style=\"margin-left:80px\">FIPS TOP-SECRET</p>\n\n<p style=\"margin-left:80px\">TLS_DHE_RSA_WITH_AES_256_GCM_SHA384</p>\n\n<p>&nbsp;&nbsp;&nbsp;</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Same error may occur when OA upgrade or downgrade is performed through Smart&nbsp;&nbsp;</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Update Manager (SUM) resulting in the following error message in the SUM.</p>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Component&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Package&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Deployment Status&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Log</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; ----------------------------------------------------------------------------------------------------------------------------------------------------------</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; cpC39063&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online HPE BladeSystem c-Class Onboard Administrator for Windows&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Update returned an error&nbsp;&nbsp;&nbsp;&nbsp; View Log</p>\n\n<p>&nbsp;</p>\n\n<p style=\"margin-left:40px\">&nbsp;&nbsp;&nbsp;When this failure occurs, the following message can be seen in the OA Smart Component&nbsp;&nbsp;log file.</p>\n\n<p style=\"margin-left:40px\">&nbsp;&nbsp; Error: 1013: Client cannot connect with the Onboard Administrator.</p>\n\n<p style=\"margin-left:40px\">Verify&nbsp;The target address is correct and can be accessed from your system.</p>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; The work-around for this problem is to disable all the ciphers that use DH&nbsp;&nbsp;key and rerun the firmware upgrade or downgrade.</p>\n\n<p style=\"margin-left:40px\">Disabling ciphers can be&nbsp;done using the CLI command DISABLE SSL CIPHER or through the GUI.&nbsp; The disabled ciphers can be re-enabled once the firmware upgrade or&nbsp;downgrade is completed.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>ILO5 Firmware Update</strong></p>\n\n<p style=\"text-align:justify\">&nbsp;</p>\n\n<p style=\"margin-left:40px; text-align:justify\">&nbsp;The UPDATE ILO command is failing to update the iLO5 firmware versions 2.10 and later on OA version 4.90 and less than 4.90. This issue is caused by the introduction of new &nbsp;signature in the iLO5 firmware version 2.10</p>\n\n<p style=\"margin-left:40px; text-align:justify\">. The work-around is to update the OA firmware&nbsp;&nbsp;to 4.95 and then try the UPDATE ILO command. This issue will not occur with OA versions&nbsp;&nbsp;&nbsp;4.95 and later.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"BL860ci2","value":"HP Integrity BL860c i2 Server Blade"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"BL870ci2","value":"HP Integrity BL870c i2 Server Blade"},{"key":"BL890ci2","value":"HP Integrity BL890c i2 Server Blade"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"","value":"HPE Integrity BL870c i6 Server Blade"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"BL860ci4","value":"HP Integrity BL860c i4 Server Blade"},{"key":"BL870ci4","value":"HP Integrity BL870c i4 Server Blade"},{"key":"BL890ci4","value":"HP Integrity BL890c i4 Server Blade"}],"sw_keys":[{"name":"OA","sw_key_expectedpath":"firmware:oa"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000GEFNA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRATG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304745464e41","Version":"HPG6"},{"DeviceName":"MB6000GEFNB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRATG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745464e42","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB4000GEFNA and MB6000GEFNB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - &nbsp;MB4000GEFNA and MB6000GEFNB Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features for :</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp;</strong> None</p>\n"}],"files":[{"bytes":"3444752","datemodified":"2021-07-25T14:40:19","file_list":["cp048592.xml","cpqsetup.exe","payload.json","setup.dll","SMKRATG6.rel"],"md5sum":"7303da84807e3550fbb94fd24ec37ddb","name":"cp048592.exe","release":"2021-07-25T14:33:04","revision":"0","sha1sum":"7c813f8a5ac17216a9dbc0db5f589e5d090c9ad9","size":"3MB","target_guids":["002340a5-4d00-3442-3030-304745464e41","002340a5-4d00-3642-3030-304745464e42"],"type_of_change":"1","version":"HPG6"}],"id":{"product":"edc1764ca6d04bbd943cd314f29904b6","version":"6cc6c91541e3402a8b9fbf189335f9f6"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB4000GEFNA and MB6000GEFNB Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows(x64) - MB4000GEFNAおよびMB6000GEFNBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB4000GEFNA","target_guid":"002340a5-4d00-3442-3030-304745464e41","type":"sata"},{"id":"MB6000GEFNB","target_guid":"002340a5-4d00-3642-3030-304745464e42","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T10:10:55","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000GEFNA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB6000GEFNB","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE 12Gb SAS Expander Card","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"firmware-Signed-5.10-build-000.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","Version":"5.10"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the HPE 12Gb/s SAS Expander "},{"lang":"ja","x_late":"このSmartコンポーネントは、HPE 12Gb/s SASエキスパンダーのファームウェアを提供します。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for Windows &ndash; HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;5.10<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; 5.09<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; 4.21(B)<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li><strong>&nbsp;</strong>Added Windows 2022 support</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong>&nbsp;&nbsp;</p>\n\n<ul>\n\t<li>Valid flag is always set to true initially so that CRC check can be performed on initstring partition and test if it is really valid.</li>\n\t<li>Move Smart Carrier Authentication to later in the boot process and move the Exception Dumper task to earlier in the process in order to support Winbond alternative Flash</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>提供名：</strong><br />\n     オンラインROMフラッシュコンポーネントfor Windows - HPE 12Gb/s SASエキスパンダーファームウェアfor HPE SmartアレイコントローラーおよびHPE HBAコントローラー</p>\n\n<p><strong>リリースバージョンおよび/または日付:</strong><br />\n     5.10<br />\n<br />\n<strong>最新の推奨またはクリティカルバージョン：</strong><br />\n     5.09<br />\n<br />\n<strong>以前のファームウェアバージョン：</strong><br />\n     4.21(B)<br />\n<br />\n<strong>ファームウェアmoの関連性:</strong><br />\n     なし  <br />\n<br />\n<strong>改善点/新しい機能：</strong></p>\n\n<ul>\n\t<li><strong> </strong>Windows 2022のサポートを追加しました</li>\n</ul>\n\n<p><strong>修正された問題点：</strong>  </p>\n\n<ul>\n\t<li>有効なフラグは最初は常にtrueに設定されているため、initstringパーティションでCRCチェックを実行し、それが本当に有効かどうかをテストできます。</li>\n\t<li>Winbondの代替フラッシュをサポートするために、スマートキャリア認証をブートプロセスの後半に移動し、Exception Dumperタスクをプロセスの前半に移動してください</li>\n</ul>\n\n<p><strong>既知の問題点:</strong><br />\n     なし        </p>\n\n<p> </p>\n"}],"files":[{"bytes":"3614560","datemodified":"2021-08-17T13:55:19","file_list":["cp049280.xml","cpqsetup.exe","firmware-Signed-5.10-build-000.bin.fw","payload.json","setup.dll"],"md5sum":"81b0e0c6455e8061d01d923fb1a716be","name":"cp049280.exe","release":"2021-09-06T00:00:00","revision":"1","sha1sum":"e14ec2b47b95d6aa9991f68e99970ddead907aab","size":"3MB","target_guids":["b99dfb74-f0bc-464f-b418-cd18c097d8f0"],"type_of_change":"1","version":"5.10"}],"id":{"product":"b57ffa2f7fe942a89e589fe3043c5ffa","version":"14f8c9bf0306473bba6d4b964471cd0a"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><u>Power cycle / cold reboot is required if firmware is upgraded from version 1.31 or earlier.</u></p>\n\n<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a><strong>:</strong></strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li>\n\t<li>Run launch_sum.bat script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><u>ファームウェアがバージョン1.31またはそれ以前からアップグレードされた場合には、電源再投入/コールドリブートが必要です。</u></p>\n\n<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a><strong></strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>ディレクトリ\\SPP20xxxxx\\hp\\swpackagesにアップデートに必要なファームウェアをコピーします。</li>\n\t<li>ISOのルートにある launch_hpsum.sh スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows (x64) - HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers"},{"lang":"cn","x_late":"面向 Windows (x64) 的在线 ROM 刷新组件 – 适用于 HPE 智能阵列控制器和 HPE HBA 控制器的 HPE 12Gb/s SAS 扩展器固件"},{"lang":"tw","x_late":"適用於 Windows (x64) 的線上 ROM 更新元件 – HPE 12Gb/s SAS 擴充卡韌體，適用於 HPE Smart Array 控制器和 HPE HBA 控制器"},{"lang":"ko","x_late":"Windows(x64)용 온라인 ROM 플래시 구성 요소 - HPE 스마트 어레이 컨트롤러 및 HPE HBA 컨트롤러용 HPE 12Gb/s SAS Expander 펌웨어"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows (x64) - HPE 12Gb/s SASエキスパンダーファームウェア for HPE SmartアレイコントローラーおよびHPE HBAコントローラー"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-10-07T07:13:49","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>To make Valid flag is always set to true initially so that CRC check can be performed on initstring partition and test if it is really valid.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Add Windows 2022 support&nbsp;</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Valid flag is always set to true initially so that CRC check can be performed on initstring partition and test if it is really valid.</li>\n\t<li>Move Smart Carrier Authentication to later in the boot process and move the Exception Dumper task to earlier in the process in order to support Winbond alternative Flash</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"12G SAS Exp Card","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the HPE Express Bay Enablement Switch Card"},{"lang":"cn","x_late":"此智能组件为HPE Express托架支持交换卡提供固件"},{"lang":"tw","x_late":"此智慧元件提供適用於 HPE Express 插槽啟用交換器卡的韌體"},{"lang":"ko","x_late":"이 스마트 구성요소는 HPE Express Bay Enablement Switch Card용 펌웨어를 제공합니다."},{"lang":"ja","x_late":"このSmartコンポーネントは、HPE Express Bay Enablement Switch Cardのファームウェアを提供します。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for Windows &ndash; HPE Express Bay Enablement Switch Card<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.78(C)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 1.78<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.78<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2019 OS</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"882144","datemodified":"2018-10-04T12:35:30","file_list":["Config.xml","cp037730.xml","cpqsetup.exe","hdr_Pedali_Rev_0x02_Btlg_0x00.bin","install.dll","pedale-VP3-20171113-1.78-release.rbf"],"md5sum":"85ad50e6556239e6dd2889b13f2dda40","name":"cp037730.exe","release":"2018-10-04T17:33:04","revision":"0","sha1sum":"134eed267b107cf43a7ce3ba0770268ef58b97ca","size":"861KB","target_guids":[],"type_of_change":"0","version":"1.78"}],"id":{"product":"52541fc006a64b3fb03d0df08b39cacd","version":"dadbf3e577d54713b0aa3d97e70ef733"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><u>Power cycle / cold reboot is required after installation for updates to take effect.</u></p>\n\n<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a><strong>:</strong></strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li>\n\t<li>Run launch_sum.bat script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><u>アップデートを有効にするために電源再投入/コールドリブートがインストール後に必要です。</u></p>\n\n<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a><strong></strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>ディレクトリ\\SPP20xxxxx\\hp\\swpackagesにアップデートに必要なファームウェアをコピーします。</li>\n\t<li>ISOのルートにある launch_hpsum.sh スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows (x64) - HPE Express Bay Enablement Switch Card"},{"lang":"cn","x_late":"Windows (x64)版在线ROM刷新组件 - HPE Express托架支持交换卡"},{"lang":"tw","x_late":"適用於 Windows (x64) 的線上 ROM 更新元件 – HPE Express 插槽啟用交換器卡"},{"lang":"ko","x_late":"Windows(x64)용 온라인 ROM 플래시 구성요소 - HPE Express Bay Enablement Switch Card"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows (x64) - HPE Express Bay Enablement Switch Card"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2018-10-28T03:23:05","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added HPE Digital Signature</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2019 OS</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"}],"sw_keys":[{"name":"HP Gen9 ExpressBay 6SFF Drive Cage","sw_key_expectedpath":"firmware:sd:switchbackplane"},{"name":"HP G9 Express Bay 6 SFF Drive Cage","sw_key_expectedpath":"firmware:sd:switchbackplane"},{"name":"HP Gen9 ExpressBay 5SFF Drive Cage","sw_key_expectedpath":"firmware:sd:switchbackplane"},{"name":"HP G9 Express Bay 5 SFF Drive Cage","sw_key_expectedpath":"firmware:sd:switchbackplane"},{"name":"DL360p Gen9 2SFF ExpressBay Bkpln","sw_key_expectedpath":"firmware:sd:switchbackplane"},{"name":"DL360 Gen9 8SFF 4PCIe+4SAS Bkpln","sw_key_expectedpath":"firmware:sd:switchbackplane"},{"name":"HP Express Bay 6 HDD Switch Card","sw_key_expectedpath":"firmware:sd:switchbackplane"},{"name":"HP DL360G9 2 SFF Express Bay Drive Cage","sw_key_expectedpath":"firmware:sd:switchbackplane"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWRTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-30475752544e","Version":"HPG2"},{"DeviceName":"MB012000GWRTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-30475752544c","Version":"HPG2"},{"DeviceName":"MB010000GWRTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-30475752544b","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB014000GWRTN, MB012000GWRTL and MB010000GWRTK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"5890717","datemodified":"2021-07-23T07:19:55","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-6.1/CP048141.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-6.1/SMOBULABPTG2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048141.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048141.scexe"],"md5sum":"f8fdcf8446cf8a3c9b09a388c8ceafac","name":"firmware-hdd-6b7ce3da0e-HPG2-6.1.x86_64.rpm","release":"2021-07-23T07:07:16","revision":"0","sha1sum":"f0f800770a6ed472419692fafde05f6abb7331bd","size":"5MB","target_guids":["4d2340a5-3042-3431-3030-30475752544e","4d2340a5-3042-3231-3030-30475752544c","4d2340a5-3042-3031-3030-30475752544b"],"type_of_change":"1","version":"HPG2"}],"id":{"product":"05a81ac262384916b1fa6e922a6cada6","version":"253a28257fe94279b7de4b1a64765488"},"installation":{"command":"CP041455.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB014000GWRTN、MB012000GWRTLおよびMB010000GWRTKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB014000GWRTN","target_guid":"4d2340a5-3042-3431-3030-30475752544e","type":"sata"},{"id":"MB012000GWRTL","target_guid":"4d2340a5-3042-3231-3030-30475752544c","type":"sata"},{"id":"MB010000GWRTK","target_guid":"4d2340a5-3042-3031-3030-30475752544b","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-26T18:11:37","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB010000GWRTK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB014000GWRTN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB012000GWRTL","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000GFEMH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNFG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304746454d48","Version":"HPG6"},{"DeviceName":"MB4000GFEMK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNFG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304746454d4b","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB2000GFEMH and MB4000GFEMK"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB2000GFEMHおよびMB4000GFEMK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB2000GFEMH and MB4000GFEMK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.&nbsp; This issue was found during supplier ongoing reliability testing.</p>\n\t</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3660160","datemodified":"2021-07-25T14:04:00","file_list":["cp048588.xml","cpqsetup.exe","HAKPNFG6.rel","payload.json","setup.dll"],"md5sum":"a89493b73c853209ba764a9908d2d4f0","name":"cp048588.exe","release":"2021-07-25T13:56:05","revision":"0","sha1sum":"a357b9d87bba7b672e8546b7b6d9edc526073879","size":"3MB","target_guids":["002340a5-4d00-3242-3030-304746454d48","002340a5-4d00-3442-3030-304746454d4b"],"type_of_change":"2","version":"HPG6"}],"id":{"product":"c3a161d21e2947f3af496f6cde08c95f","version":"264e0011088b4cf19fed0b8bfb7147f0"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB2000GFEMH and MB4000GFEMK Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows(x64) - MB2000GFEMHおよびMB4000GFEMKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB2000GFEMH","target_guid":"002340a5-4d00-3242-3030-304746454d48","type":"sata"},{"id":"MB4000GFEMK","target_guid":"002340a5-4d00-3442-3030-304746454d4b","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T09:16:09","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.Â  This issue was found during supplier ongoing reliability testing.</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.&nbsp;This issue was found during supplier ongoing reliability testing.</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000GFEMK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB2000GFEMH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under Red Hat Enterprise Linux 8 Update 3."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"25226","datemodified":"2021-02-11T00:34:01","file_list":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib/.build-id","./usr/lib/.build-id/c6","./usr/lib/.build-id/c6/28b8217315bea3e5ba8b5181d0344ffc78222b","./usr/lib64/libbnxt_re-218.0.7.0.so","./usr/lib64/libbnxt_re-rdmav25.so","./usr/lib64/libbnxt_re.so","./usr/share/smartupdate/libbnxt_re/component.xml"],"md5sum":"c13b8766d07e511ce475f4cad413d239","name":"libbnxt_re-218.0.7.0-rhel8u3.x86_64.rpm","release":"2021-02-11T00:31:30","revision":"0","sha1sum":"6201a9c882b41da5d1801be4dd7bb59f7d39991f","size":"24KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"type_of_change":"0","version":"218.0.7.0"}],"id":{"product":"b6f6f77678514383bdf949306b683bf3","version":"8acb3a0ef8c64bbb9919ed6dd31cf314"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"text-align:left\">rpm -ivh &lt;bnxt_rooce &gt;.rpm --force [--replacefiles]</p>\n\n<p style=\"text-align:left\">Use --force or --replacefiles options while installing or updating the HPE Broadcom RoCE library which may conflict with inbox library</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E RoCE Library for Red Hat Enterprise Linux 8 Update 3."}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p style=\"margin-left:0px; margin-right:0px\">Initial release.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"libbnxt_re","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"The MPT2SAS controller driver component for VMware vSphere 6.5, for use with HPE Smart Update Manager."},{"lang":"ja","x_late":"HPE Smart Update Managerで使用するMPT2SASコントローラードライバーコンポーネント for VMware vSphere 6.5"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"282781","datemodified":"2017-05-24T03:40:50","file_list":["/cp032277.xml","/mpt2sas-15.10.07.00-esxi5.5-4778920.zip","/mpt2sas-15.10.07.00-esxi5.5-4778920.zip/mpt2sas-15.10.07.00-esxi5.5-offline_bundle-4778920.zip","/mpt2sas-15.10.07.00-esxi5.5-4778920.zip/scsi-mpt2sas-15.10.07.00-1OEM.550.0.0.1331820.x86_64.vib","/mpt2sas-15.10.07.00-esxi5.5-4778920.zip/doc/README.txt","/mpt2sas-15.10.07.00-esxi5.5-4778920.zip/doc/release_note_scsi-mpt2sas_15.10.07.00-1OEM.550.0.0.1331820.txt","/mpt2sas-15.10.07.00-esxi5.5-4778920.zip/mpt2sas-15.10.07.00-esxi5.5-offline_bundle-4778920.zip/index.xml","/mpt2sas-15.10.07.00-esxi5.5-4778920.zip/mpt2sas-15.10.07.00-esxi5.5-offline_bundle-4778920.zip/vendor-index.xml","/mpt2sas-15.10.07.00-esxi5.5-4778920.zip/mpt2sas-15.10.07.00-esxi5.5-offline_bundle-4778920.zip/metadata.zip","/mpt2sas-15.10.07.00-esxi5.5-4778920.zip/mpt2sas-15.10.07.00-esxi5.5-offline_bundle-4778920.zip/vib20/scsi-mpt2sas/Avago_bootbank_scsi-mpt2sas_15.10.07.00-1OEM.550.0.0.1331820.vib","/mpt2sas-15.10.07.00-esxi5.5-4778920.zip/mpt2sas-15.10.07.00-esxi5.5-offline_bundle-4778920.zip/metadata.zip/vendor-index.xml","/mpt2sas-15.10.07.00-esxi5.5-4778920.zip/mpt2sas-15.10.07.00-esxi5.5-offline_bundle-4778920.zip/metadata.zip/vmware.xml","/mpt2sas-15.10.07.00-esxi5.5-4778920.zip/mpt2sas-15.10.07.00-esxi5.5-offline_bundle-4778920.zip/metadata.zip/vibs/scsi-mpt2sas--49695319.xml","/mpt2sas-15.10.07.00-esxi5.5-4778920.zip/mpt2sas-15.10.07.00-esxi5.5-offline_bundle-4778920.zip/metadata.zip/bulletins/mpt2sas-15.10.07.00-esxi5.5.xml"],"md5sum":"3ec7611c4b4fdc254ddf813bb82977de","name":"cp032277.zip","release":"2017-05-24T03:38:05","revision":"0","sha1sum":"b00a2c0c0c5c659aea6545f0c7744689695c04bf","size":"276KB","target_guids":[],"type_of_change":"0","version":"2017.01.20","vib_list":[{"name":"scsi-mpt2sas","version":"15.10.07.00-1OEM.550.0.0.1331820"}]}],"id":{"product":"4cc21db9534d4bd8a0a68234daf7c362","version":"f602658f34044dda8776eb434f2c3ccb"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant</strong></p>\n\n<p><strong>Remote Online: </strong></p>\n\n<ul>\n\t<li>&nbsp;Place the SPP on a USB key using the HPE USB Key Utility:&nbsp;<a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us</a>&nbsp;</li>\n\t<li>&nbsp;Place the desired driver to be updated in the directory, /SPP20xxxxx/hp/swpackages on the USB key.</li>\n\t<li>&nbsp;Mount the USB key on a remote server running Windows or Linux</li>\n\t<li>&nbsp;CD /hp/swpackages and ./hpsum</li>\n\t<li>&nbsp;Select the next button</li>\n\t<li>&nbsp;Click Add Single Target</li>\n\t<li>&nbsp;Type the IP or DNS address of the ESXi host to be updated</li>\n\t<li>&nbsp;Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>&nbsp;Follow Smart Update Manager Steps and complete the update.</li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>&nbsp;Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>&nbsp;Use VMware VUM or esxcli commands to install the offline bundle.</li>\n\t<li>&nbsp;Refer to VMware documentation for information on VUM and the esxcli commands.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"LSI Logic Corporation"}],"name":[{"lang":"en","x_late":"HPE H2xx SAS/SATA Host Bus Adapter (64-bit) Driver for vSphere 6.5 (Driver Component)."},{"lang":"ja","x_late":"vSphere 6.5用HPE H2xx SAS/SATAホストバスアダプター（64-bi）ドライバー（ドライバーコンポーネント）。"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"0087","subdev":"0042","subven":"1590","target_guid":"","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2017-05-26T05:50:30","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Fixes minor installation issue with the driver on VMware vSphere 6.5.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p style=\"margin-left:.1in\"><strong>Change implemented in version 2017.01.20(A)</strong>:</p>\n\n<ul>\n\t<li>Updated to support Service Pack for ProLiant version 2017.07.0.<br />\n\t<strong>Note:</strong> If component version 2017.01.20 was previously installed, then it is not necessary to upgrade to version 2017.01.20(A).</li>\n</ul>\n\n<p style=\"margin-left:.1in\"><strong>Issues resolved in version 2017.01.20</strong>:</p>\n\n<ul>\n\t<li>Fixes minor installation issue with the driver on VMware vSphere 6.5.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"}],"sw_keys":[{"name":"scsi-mpt2sas:15.10.07.00-1OEM.550.0.0.1331820","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]},{"key":"7800374","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"en","x_late":"This package contains utilities and libraries to enable HPE Storage fibre channel over Ethernet array connectivity on SUSE Linux Enterprise Server 12 for Emulex Host Bus Adapters and Mezzanine Host Bus Adapters."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1666754","datemodified":"2021-08-27T06:16:11","file_list":["./opt/broadcom/sles12sp5/i386/lib/libbrcmdfc.so","./opt/broadcom/sles12sp5/i386/lib/libbrcmdfc.so.12","./opt/broadcom/sles12sp5/i386/lib/libbrcmdfc.so.12.0.1329","./opt/broadcom/sles12sp5/i386/lib/libbrcmemsdm.so","./opt/broadcom/sles12sp5/i386/lib/libbrcmhbaapi.so","./opt/broadcom/sles12sp5/x86_64/lib64/libbrcmdfc.so","./opt/broadcom/sles12sp5/x86_64/lib64/libbrcmdfc.so.12","./opt/broadcom/sles12sp5/x86_64/lib64/libbrcmdfc.so.12.0.1329","./opt/broadcom/sles12sp5/x86_64/lib64/libbrcmemsdm.so","./opt/broadcom/sles12sp5/x86_64/lib64/libbrcmhbaapi.so","./usr/lib/libbrcmdfc.so","./usr/lib/libbrcmdfc.so.12","./usr/lib/libbrcmdfc.so.12.0.1329","./usr/lib/libbrcmemsdm.so","./usr/lib/libbrcmhbaapi.so","./usr/lib64/libbrcmdfc.so","./usr/lib64/libbrcmdfc.so.12","./usr/lib64/libbrcmdfc.so.12.0.1329","./usr/lib64/libbrcmemsdm.so","./usr/lib64/libbrcmhbaapi.so","./usr/share/smartupdate/HPE-CNA-FC-Broadcom-Enablement-Kit/component.xml"],"md5sum":"fec8cfdaab31613d9194982c24f4059e","name":"HPE-CNA-FC-Broadcom-Enablement-Kit-12.0.1339.0-1.sles12sp5.x86_64.rpm","release":"2021-08-27T06:09:03","revision":"0","sha1sum":"f364de425320f1b84d5d29de9285567696edb7c9","size":"1MB","target_guids":[],"type_of_change":"1","version":"12.0.1339.0"}],"id":{"product":"faac61e41e2d45a7b22939fd8ceb62c0","version":"8a00beb0eac944b2a635ff8b405baccc"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>There has been a change to the enablement kits in this release.&nbsp; They are now vendor specific kits.&nbsp;&nbsp; It is recommended that you uninstall any previous kits prior to installation of this component.<br />\n<br />\nTo uninstall the hp-fc-enablement RPM use the following command:</p>\n\n<p>&nbsp;&nbsp; # rpm -e hp-fc-enablement-&lt;version&gt;.noarch.rpm<br />\n<br />\nTo install the hp-CNA-fc-enablement RPM use the following command:</p>\n\n<p>&nbsp;&nbsp; # rpm -ivh HP-CNA-FC-Broadcom-Enablement-Kit-&lt;version&gt;.&lt;OS&gt;.&lt;architecture&gt;.rpm<br />\n<br />\nThis version of the enablement kit does not provide the additional functionality of rebuilding the ram disk or setting driver parameters as the previous versions had done.&nbsp; Please refer to the &ldquo;Additional setup&rdquo; section of the Native Linux Device-Mapper Multipath for HPE StorageWorks Arrays reference guide for instructions on how to perform these functions.&nbsp; The reference guide is available at the following link:<br />\n&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; <a href=\"http://www.hpe.com/storage/spock/\">http://www.hpe.com/storage/spock/</a><br />\n&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex(BRCM) Fibre Channel Over Ethernet Enablement Kit for Host Bus Adapters and Mezzanine Host Bus Adapters for SUSE Linux Enterprise Server 12"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T11:01:11","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to version: 12.0.1339.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"}],"sw_keys":[{"name":"HPE-CNA-FC-Broadcom-Enablement-Kit","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWRTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLPeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757525443","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB008000GWRTC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB008000GWRTC Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"18503306","datemodified":"2021-08-30T20:24:52","file_list":["/CP048331_BUILD_2.data","/CP048331.vmexe","/CP048331.vmexe64","/CP048331.vmfile","/CP048331_VMw.zip","/CP048331.xml","/payload.json","/CP048331_VMw.zip/index.xml","/CP048331_VMw.zip/vendor-index.xml","/CP048331_VMw.zip/metadata.zip","/CP048331_VMw.zip/vib20/CP048331/HPE_bootbank_CP048331_HPG1.2-7.0.0.15843807.vib","/CP048331_VMw.zip/metadata.zip/vendor-index.xml","/CP048331_VMw.zip/metadata.zip/vmware.xml","/CP048331_VMw.zip/metadata.zip/vibs/CP048331--6204746841176718845.xml","/CP048331_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048331_HPG1.2-7.0.0.15843807.xml"],"md5sum":"a7d4b1ab85581b70f26814672d6c45dd","name":"CP048331.zip","release":"2021-08-30T20:20:08","revision":"0","sha1sum":"8e9fce27ccee73be883bf105977af66e12250ab2","size":"17MB","target_guids":["4d2340a5-3042-3830-3030-304757525443"],"type_of_change":"1","version":"HPG1","vib_list":[{"name":"CP048331","version":"HPG1.2-7.0.0.15843807"}]}],"id":{"product":"a6447acbde7f4368991a3df1503f91e8","version":"ca282a25bee64bf087ea6774b2bdb640"},"installation":{"command":"CP041481.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB008000GWRTC Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB008000GWRTCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB008000GWRTC","target_guid":"4d2340a5-3042-3830-3030-304757525443","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-05T18:50:09","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000GWRTC","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO001600KWVNB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b57564e42","Version":"HPK3"},{"DeviceName":"MO003200KWVNC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b57564e43","Version":"HPK3"},{"DeviceName":"MO006400KWVND","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b57564e44","Version":"HPK3"},{"DeviceName":"MT001600KWSTB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3130-3630-304b57535442","Version":"HPK3"},{"DeviceName":"MT003200KWSTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3330-3230-304b57535443","Version":"HPK3"},{"DeviceName":"MT006400KWSTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3630-3430-304b57535444","Version":"HPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MO001600KWVNB, MO003200KWVNC, MO006400KWVND, MT001600KWSTB, MT003200KWSTC and MT006400KWSTD"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MO001600KWVNB、MO003200KWVNC、MO006400KWVND、MT001600KWSTB、MT003200KWSTC、およびMT006400KWSTD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for VMware ESXi - MO001600KWVNB, MO003200KWVNC, MO006400KWVND, MT001600KWSTB, MT003200KWSTC and MT006400KWSTD Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"20960508","datemodified":"2021-08-26T11:49:50","file_list":["/CP048478_BUILD_4.data","/CP048478.vmexe","/CP048478.vmexe64","/CP048478.vmfile","/CP048478_VMw.zip","/CP048478.xml","/payload.json","/CP048478_VMw.zip/index.xml","/CP048478_VMw.zip/vendor-index.xml","/CP048478_VMw.zip/metadata.zip","/CP048478_VMw.zip/vib20/CP048478/HPE_bootbank_CP048478_HPK3.4-7.0.0.15843807.vib","/CP048478_VMw.zip/metadata.zip/vendor-index.xml","/CP048478_VMw.zip/metadata.zip/vmware.xml","/CP048478_VMw.zip/metadata.zip/vibs/CP048478-2379620384603753753.xml","/CP048478_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048478_HPK3.4-7.0.0.15843807.xml"],"md5sum":"19f86e39c87e02ae80dbe4459a37a9bf","name":"CP048478.zip","release":"2021-08-26T11:44:47","revision":"0","sha1sum":"a7d8b60aa8265e4103613822054b504192381511","size":"19MB","target_guids":["4d2340a5-304f-3130-3630-304b57564e42","4d2340a5-304f-3330-3230-304b57564e43","4d2340a5-304f-3630-3430-304b57564e44","4d2340a5-3054-3130-3630-304b57535442","4d2340a5-3054-3330-3230-304b57535443","4d2340a5-3054-3630-3430-304b57535444"],"type_of_change":"1","version":"HPK3","vib_list":[{"name":"CP048478","version":"HPK3.4-7.0.0.15843807"}]}],"id":{"product":"a2580f8b900b4c35b050bbb3d0fe3010","version":"4e5072c0b6264b18b95611f6d1e235b8"},"installation":{"command":"CP040194.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi - MO001600KWVNB, MO003200KWVNC, MO006400KWVND, MT001600KWSTB, MT003200KWSTC and MT006400KWSTD Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - MO001600KWVNB、MO003200KWVNC、MO006400KWVND、MT001600KWSTB、MT003200KWSTC、およびMT006400KWSTDドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MO006400KWVND","target_guid":"4d2340a5-304f-3630-3430-304b57564e44","type":"nvme"},{"id":"MO003200KWVNC","target_guid":"4d2340a5-304f-3330-3230-304b57564e43","type":"nvme"},{"id":"MO001600KWVNB","target_guid":"4d2340a5-304f-3130-3630-304b57564e42","type":"nvme"},{"id":"MT001600KWSTB","target_guid":"4d2340a5-3054-3130-3630-304b57535442","type":"nvme"},{"id":"MT003200KWSTC","target_guid":"4d2340a5-3054-3330-3230-304b57535443","type":"nvme"},{"id":"MT006400KWSTD","target_guid":"4d2340a5-3054-3630-3430-304b57535444","type":"nvme"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T18:03:37","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Fixed SSD weargauge report error issue.</li>\n\t<li>Fixed Assign FWState as TR_DONE_ERR at the correct location.</li>\n\t<li>Prepare proper response data for Get Message Type Supported MCTP Command.</li>\n\t<li>Added code to preserve current feature values cross live firmware update.</li>\n\t<li>Allocate 4 bytes instead of 2 bytes for parameter code.</li>\n\t<li>Changed the value for NLB equal to NSize -1.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MT006400KWSTD","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO001600KWVNB","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT003200KWSTC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO003200KWVNC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO006400KWVND","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT001600KWSTB","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The HPE Agentless Management Service (hp-ams) provides support for HPE Integrated Lights-Out 4 (HPE iLO 4) Embedded Health and Alerting."},{"lang":"ja","x_late":"HPE Agentless Management Service（hp-ams）は、HPE Integrated Lights Out 4（HPE iLO 4）内蔵ヘルスおよびアラートのサポートを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Diagnosing connection issues:</strong></p>\n\n<p>Verify that the HPE iLO 4 is talking to SNMP from a Linux system with net-snmp utilities installed:</p>\n\n<p style=\"margin-left:40px\"><em>snmpwalk -t 60 -v 2c -Ox -c</em> <strong>iLO4_configured_community_string</strong> <strong>iLO4_IP_Address</strong>&nbsp;<em>1.3.6.1.4.1.232.1.1</em></p>\n\n<p>Verify that HPE AMS is operating on the Server:</p>\n\n<p style=\"margin-left:40px\"><em>snmpwalk -t 60 -v 2c -Ox -c</em> <strong>iLO4_configured_community_string</strong> <strong>iLO4_IP_Address</strong>&nbsp;<em>1.3.6.1.4.1.232.5.1</em></p>\n"},{"lang":"ja","x_late":"<p><strong>接続の問題の診断：</strong></p>\n\n<p>HPE iLO 4が、net-snmpユーティリティがインストールされたLinuxシステムから、SNMPに通信していることを確認：</p>\n\n<p style=\"margin-left:40px\"><em>snmpwalk -t 60 -v 2c -Ox -c</em> <strong>iLO4_configured_community_string</strong> <strong>iLO4_IP_Address</strong> <em>1.3.6.1.4.1.232.1.1</em></p>\n\n<p>サーバー上でHPE AMSが動作していることを確認：</p>\n\n<p style=\"margin-left:40px\"><em>snmpwalk -t 60 -v 2c -Ox -c</em> <strong>iLO4_configured_community_string</strong> <strong>iLO4_IP_Address</strong> <em>1.3.6.1.4.1.232.5.1</em></p>\n"}],"files":[{"bytes":"746095","datemodified":"2021-10-06T05:19:20","file_list":["./etc/sysconfig/hp-ams","./opt/hp/hp-ams","./opt/hp/hp-ams/hp-ams.license","./sbin/amsHelper","./usr/lib/systemd/system/hp-ams.service","./usr/share/man/man8/amsHelper.8.gz","./usr/share/smartupdate/hp-ams/component.xml"],"md5sum":"53f411c48f7eba5c4a4c1428024ec00e","name":"hp-ams-2.10.4-885.4.sles15.x86_64.rpm","release":"2021-10-06T05:07:20","revision":"0","sha1sum":"afd8f4b5b6650d237b8eb452a34b7dd0164ba087","size":"728KB","target_guids":[],"type_of_change":"0","version":"2.10.4"}],"id":{"product":"3dd3ab05c92946afa133f2b171e42532","version":"cdd0e76d85f9404b9a2176a39bcbb901"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"","SubRequirements":[]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>To install the package type:</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;rpm -ivh hp-ams-&lt;version&gt;.rpm</p>\n\n<p>To check whether the package is loaded properly type:</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;systemctl status hp-ams</p>\n\n<p>Additional help is available by typing:</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;man amshelper</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE ProLiant Agentless Management Service for SUSE LINUX Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"id":"5219994","target_guid":"","type":"other"},{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3300","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3302","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-21T13:31:37","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>Addressed&nbsp;a small amount of memory leak as documented in the Customer Advisory, <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00053824en_us\" style=\"color:#0563c1; text-decoration:underline\">a00053824en_us</a></li>\n\t<li>&nbsp;NVMe drive information is now available in the CPQSE.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>Drive&nbsp;status all shows failed on SL4540 Gen8 H220 [LSI] ILO4 due to&nbsp; incorrect SCSI command tags.</li>\n\t<li>Addressed issue where hp-ams may fail to start when&nbsp;U.3 NVMe devices are installed in the system</li>\n\t<li>The HPE Synergy 6810C 25/50Gb Ethernet Adapter not displaying information in hp-ams is now resolved</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"}],"sw_keys":[{"name":"hp-ams","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"XP0120GFJSL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"ASAXHPS4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5800-3050-3132-3047464a534c","Version":"HPS4"},{"DeviceName":"XP0240GFJSN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"ASAXHPS4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5800-3050-3234-3047464a534e","Version":"HPS4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: XP0120GFJSL and XP0240GFJSN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - &nbsp;XP0120GFJSL and XP0240GFJSN&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPS4<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPS2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPS2</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3596280","datemodified":"2021-07-25T19:48:04","file_list":["ASAXHPS4.rel","cp048646.xml","cpqsetup.exe","payload.json","setup.dll"],"md5sum":"53cf6b7eed55904a855add4083ef075a","name":"cp048646.exe","release":"2021-07-25T19:40:05","revision":"0","sha1sum":"3a6a62c104f43241946e3ea9ed119c214ae0e745","size":"3MB","target_guids":["002340a5-5800-3050-3132-3047464a534c","002340a5-5800-3050-3234-3047464a534e"],"type_of_change":"1","version":"HPS4"}],"id":{"product":"c1ebf0647264498cacbe8929505ef3cf","version":"dfb2310430084a9da6b67e24ec6fc4a7"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - XP0120GFJSL and XP0240GFJSN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - XP0120GFJSLおよびXP0240GFJSNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"XP0120GFJSL","target_guid":"002340a5-5800-3050-3132-3047464a534c","type":"sata"},{"id":"XP0240GFJSN","target_guid":"002340a5-5800-3050-3234-3047464a534e","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T18:08:09","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"XP0120GFJSL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"XP0240GFJSN","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 1Gb 2-port 363i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1523103C1989","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37CE15900215","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900216","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366i Communication Board","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521159000FF","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 369i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900247","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C337F","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C3380","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 560FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-10FB103C17D0","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C339E","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C17D1","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C8157","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 560SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-10FB103C17D3","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FC","Version":"10.54.7"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D2","Version":"10.54.4"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FD","Version":"10.54.7"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D1","Version":"10.54.4"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D315900219","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900217","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 563i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_FVL4HP.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1581159000F8","Version":"1.1375.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D215900218","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 561T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1528103C211A","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 561FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1528103C192D","Version":"1.2836.0"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"tw","x_late":"本套件包含可升級 HPE Intel 乙太網路網路卡 ROM 映像的公用程式和二進位檔，適用於 Linux x86_64 平台。"},{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Intel Ethernet NICs ROM images running under Linux x86_64 platform."},{"lang":"ko","x_late":"이 패키지에는 Linux x86_64 플랫폼에서 실행되는 HPE Intel Ethernet NICs ROM 이미지를 업그레이드할 수 있는 유틸리티와 바이너리가 포함되어 있습니다."},{"lang":"cn","x_late":"该软件包包含实用程序和二进制文件，可用于升级在Linux x86_64平台下运行的HPE Intel以太网卡ROM映像。"},{"lang":"ja","x_late":"このパッケージには、Linux x86_64プラットフォームで動作するHPE Intel Ethernet NIC ROMイメージをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p>\n\n<table border=\"1\">\n\t<thead>\n\t\t<tr>\n\t\t\t<th>NIC</th>\n\t\t\t<th>EEPROM/NVM Version</th>\n\t\t\t<th>OROM Version</th>\n\t\t\t<th>Single NVM Version</th>\n\t\t</tr>\n\t</thead>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 1Gb 2-port 361i Adapter</td>\n\t\t\t<td>8000106F</td>\n\t\t\t<td>1.2836.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 1Gb 2-port 361T Adapter</td>\n\t\t\t<td>80001147</td>\n\t\t\t<td>1.2836.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 1Gb 2-port 363i Adapter</td>\n\t\t\t<td>80000D00</td>\n\t\t\t<td>1.2836.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 1Gb 4-port 366i Communication Board</td>\n\t\t\t<td>80000EBF</td>\n\t\t\t<td>1.2836.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 1Gb 4-port 366i Adapter</td>\n\t\t\t<td>8000105E</td>\n\t\t\t<td>1.2836.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 1Gb 4-port 366FLR Adapter</td>\n\t\t\t<td>80001148</td>\n\t\t\t<td>1.2836.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 1Gb 4-port 366T Adapter</td>\n\t\t\t<td>80001146</td>\n\t\t\t<td>1.2836.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 1Gb 2-port 368i Adapter</td>\n\t\t\t<td>800027FA</td>\n\t\t\t<td>1.2836.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 1Gb 2-port 368FLR-MMT Adapter</td>\n\t\t\t<td>800027F8</td>\n\t\t\t<td>1.2836.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 1Gb 4-port 369i Adapter</td>\n\t\t\t<td>800027FB</td>\n\t\t\t<td>1.2836.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 560FLR-SFP+ Adapter</td>\n\t\t\t<td>80000838</td>\n\t\t\t<td>1.2836.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 560SFP+ Adapter</td>\n\t\t\t<td>80000835</td>\n\t\t\t<td>1.2836.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 561T Adapter</td>\n\t\t\t<td>80000636</td>\n\t\t\t<td>1.2836.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 561FLR-T Adapter</td>\n\t\t\t<td>800005B6</td>\n\t\t\t<td>1.2836.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 568i Adapter</td>\n\t\t\t<td>800027FC</td>\n\t\t\t<td>1.2836.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter</td>\n\t\t\t<td>800027F8</td>\n\t\t\t<td>1.2836.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 568FLR-MMT Adapter</td>\n\t\t\t<td>800027F8</td>\n\t\t\t<td>1.2836.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 563i Adapter</td>\n\t\t\t<td>800035C0</td>\n\t\t\t<td>1.1375.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 562FLR-SFP+ Adapter</td>\n\t\t\t<td>80009655</td>\n\t\t\t<td>1.2836.0</td>\n\t\t\t<td>10.54.7</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 562FLR-T Adapter</td>\n\t\t\t<td>8000137D</td>\n\t\t\t<td>1.2836.0</td>\n\t\t\t<td>10.54.4</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 562SFP+ Adapter</td>\n\t\t\t<td>800095AA</td>\n\t\t\t<td>1.2836.0</td>\n\t\t\t<td>10.54.7</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 562T Adapter</td>\n\t\t\t<td>8000137C</td>\n\t\t\t<td>1.2836.0</td>\n\t\t\t<td>10.54.4</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>The combo image v1.2836.0 includes: Boot Agent: 1GbE - v1.5.88, 10GbE - v2.4.44, 40GbE - v1.1.18 &amp; UEFI Drivers: 1GbE - v9.4.06, 10GbE - v7.8.13, 40GbE - v4.4.12</p>\n\n<p>The combo image v1.1375.0 includes: Boot Agent: 1GbE - v1.5.72, 10GbE - v2.3.46, 40GbE - v1.0.21 &amp; UEFI Drivers: 1GbE - v6.9.13, 10GbE - v5.0.20, 40GbE - v1.5.14</p>\n\n<p>Single NVM Version is new firmware format which represent an unified version in place of the previously used EEPROM/NVM Version or OROM version.</p>\n"}],"files":[{"bytes":"11100323","datemodified":"2021-08-28T00:30:47","file_list":["./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/CP047024.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/CP047024.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/deps/libs/libnvmupdatelinux.so","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/nic_fw/BootIMG.FLB","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/nic_fw/BootIMG_FVL4HP.FLB","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/nic_fw/HPE_1G_Adapter_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/nic_fw/HPE_361T.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/nic_fw/HPE_361T_H65030-003_2.25_80001147.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/nic_fw/HPE_361i_I350_2p_Cu_NCSI_1.61_WOL_8000106F.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/nic_fw/HPE_361i_I350_2p_Cu_NCSI_1.61_WOL_8000106F.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/nic_fw/HPE_363i_I350_2p_KX_NCSI_LS_80000D00.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/nic_fw/HPE_363i_I350_2p_KX_NCSI_LS_80000D00.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/nic_fw/HPE_366FLR_G41713-00x_80001148.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/nic_fw/HPE_366FLR_G41713-00x_80001148.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/nic_fw/HPE_366T_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/nic_fw/HPE_366T_Quad_H73104-00x_80001146.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/nic_fw/HPE_366T_Quad_H73104-00x_80001146.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/nic_fw/HPE_366i_I350_4p_Cu_NCSI_1.61_00FF_1590_80000EBF.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/nic_fw/HPE_366i_I350_4p_Cu_NCSI_1.61_00FF_1590_80000EBF.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/nic_fw/HPE_366i_I350_4p_Cu_NCSI_1.61_8000105E.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/nic_fw/HPE_366i_I350_4p_Cu_NCSI_1.61_8000105E.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/nic_fw/HPE_369i_88E1512_P01_88E1512_P23_NCSI_5p10_800027FB.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/nic_fw/HPE_40G_Adapter_562FLR-SFP_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/nic_fw/HPE_40G_Adapter_KR_VPD_MAP_FVL4HP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/nic_fw/HPE_40G_Adapter_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/nic_fw/HPE_560FLR-SFP_2_port_G42955-0xx_2.69_80000838.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/nic_fw/HPE_561FLR-T_G74768-000_update_EDC_2.19_800005B6.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/nic_fw/HPE_561T_OCSD_G88062-000_E1_2.46_80000636.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/nic_fw/HPE_562FLR-SFP_DP_H47655-000_80009655.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/nic_fw/HPE_562FLR-T_B0_AT2_3p10_8000137D.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/nic_fw/HPE_562SFP_DP_H44490-000_800095AA.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/nic_fw/HPE_562T_B0_AT2_MCTP_3p10_8000137C.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/nic_fw/HPE_563i_KR_DP_800035C0.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/nic_fw/HPE_568i_Backplane_2x10G_P01_NCSI_5p10_800027FC.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/nic_fw/HPE_Apollo_PHY_Auto_Detect_NCSI_5p10_800027F8.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/nic_fw/HPE_DL160_PHY_Auto_Detect_P01_88E1514_P23_NCSI_5p10_800027FA.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/nic_fw/HPE_FVL_FPK_Adapter_LOM_568i_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/nic_fw/HPE_FVL_FPK_Adapter_LOM_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/nic_fw/HPE_SFX_OCSD_G43260-0xx.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/nic_fw/HPE_SFX_OCSD_G43260-0xx.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/nic_fw/HPE_XG_Adapter_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/nic_fw/HPE_XG_SGVL_Adapter_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/nic_fw/hpesinglenvmconfig.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/nic_fw/hpnvmupdate.cfg","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/nic_fw/nvmupdate.sh","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.6-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP047024.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP047024.scexe"],"md5sum":"17545f9b6641a1a886b935ef5a5d41a8","name":"firmware-nic-intel-1.22.6-1.1.x86_64.rpm","release":"2021-08-28T00:19:25","revision":"0","sha1sum":"adaa1fdf7d9f3f8ff08d1bccecca1f8e237d6e74","size":"10MB","target_guids":["a6b1a447-382a-5a4f-8086-1523103C1989","a6b1a447-382a-5a4f-8086-37CE15900215","a6b1a447-382a-5a4f-8086-37D115900216","a6b1a447-382a-5a4f-8086-1521159000FF","a6b1a447-382a-5a4f-8086-37D115900247","a6b1a447-382a-5a4f-8086-1521103C337F","a6b1a447-382a-5a4f-8086-1521103C3380","a6b1a447-382a-5a4f-8086-10FB103C17D0","a6b1a447-382a-5a4f-8086-1521103C339E","a6b1a447-382a-5a4f-8086-1521103C17D1","a6b1a447-382a-5a4f-8086-1521103C8157","a6b1a447-382a-5a4f-8086-10FB103C17D3","a6b1a447-382a-5a4f-8086-1572103C22FC","a6b1a447-382a-5a4f-8086-1563159000D2","a6b1a447-382a-5a4f-8086-1572103C22FD","a6b1a447-382a-5a4f-8086-1563159000D1","a6b1a447-382a-5a4f-8086-37D315900219","a6b1a447-382a-5a4f-8086-37D115900217","a6b1a447-382a-5a4f-8086-1581159000F8","a6b1a447-382a-5a4f-8086-37D215900218","a6b1a447-382a-5a4f-8086-1528103C211A","a6b1a447-382a-5a4f-8086-1528103C192D"],"type_of_change":"0","version":"1.22.6"}],"id":{"product":"d8c86b5c3ce7444dbebf7bd215bf1a32","version":"a370c322c0ff46a4918a7a853767d75b"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><em><strong><em><strong><em><strong><em><strong>Updating firmware with rpm installed:</strong></em></strong></em></strong></em></strong></em></p>\n\n<ul>\n\t<li>Install the NIC firmware rpm using the commmand:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.rpm.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<br />\n\t<li>The CP047024.scexe script is located in the &#39;scexe-compat&#39; folder. Further information&nbsp;is available in CP045035.txt file in the &#39;firmware-nic-*&#39; folder. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li>\n\t<br />\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li><em>./</em>CP047024<em>.scexe</em> in the &#39;/usr/lib/x86_64-linux-gnu&#39; location (OR)</li>\n\t\t<li><em>./setup</em> in the &#39;firmware-nic-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<br />\n\t<li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em></li>\n</ul>\n\n<p><br />\n<em><strong>Updating firmware without installing the rpm:</strong></em></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<br />\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run <em>./hpsetup</em> to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<br />\n\t<li>&nbsp;</li>\n</ul>\n\n<p><em><strong>Additional Information:</strong></em></p>\n\n<ul>\n\t<li>Under certain scenarios, after updating the EPROM you may be required to reboot the&nbsp;system and re-run the component&nbsp;in order&nbsp;to update the flash ROM (OROM) on the adapter(s).</li>\n\t<li>The results of the firmware upgrade are saved in the CP047024.log file, located at the /var/cpq/ directory.</li>\n\t<li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li>\n\t<li>Installing the firmware rpm package (rpm -ivh) does not update the adapter firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the adapter requires following the&nbsp;above outlined steps.&nbsp;</li>\n\t<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed. For more information about downgrade limitation, refer to the following Customer advisory:&nbsp;<br />\n\t<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00069764en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00069764en_us</a></li>\n\t<li>AC Power Cycle is required after firmware installation for updates&nbsp;to take effect for the following network adapters:<br />\n\tHPE Ethernet 1Gb 2-port 368i Adapter<br />\n\tHPE Ethernet 1Gb 4-port 369i Adapter<br />\n\tHPE Ethernet 1Gb 2-port 368FLR-MMT Adapter<br />\n\tHPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter<br />\n\tHPE Ethernet 10Gb 2-port 568FLR-MMT Adapter</li>\n</ul>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"HPE Intel 線上韌體升級公用程式 (適用於 Linux x86_64)"},{"lang":"en","x_late":"HPE Intel Online Firmware Upgrade Utility for Linux x86_64"},{"lang":"ko","x_late":"Linux x86_64용 HPE Intel 온라인 펌웨어 업그레이드 유틸리티"},{"lang":"cn","x_late":"适用于 Linux x86_64 的 HPE Intel 在线固件升级实用程序"},{"lang":"ja","x_late":"HPE Intelオンラインファームウェアアップグレードユーティリティ for Linux x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"1523","subdev":"1989","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1523103c1989","type":"pci","ven":"8086"},{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00FF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1521159000ff","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"1521","subdev":"337F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c337f","type":"pci","ven":"8086"},{"dev":"1521","subdev":"3380","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-1521103c3380","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"1521","subdev":"339E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c339e","type":"pci","ven":"8086"},{"dev":"1521","subdev":"17D1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c17d1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"8157","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c8157","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"1581","subdev":"00F8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1581159000f8","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c211a","type":"pci","ven":"8086"},{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c192d","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product addresses an issue where Systems Insight Display (SID) modul is green when there&#39;s no Network connection.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 8 update 4 and SUSE Linux Enterprise Server 15 Service Pack 3</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"INTEL","sw_key_expectedpath":"firmware:intel_nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"tw","x_late":"System Management Homepage 針對單一伺服器管理提供一個統合式檢視，突顯緊密整合的管理功能，包括效能、錯誤、安全性、診斷、組態及軟體變更管理。"},{"lang":"en","x_late":"The System Management Homepage provides a consolidated view for single server management highlighting tightly integrated management functionalities including performance, fault, security, diagnostic, configuration, and software change management."},{"lang":"ko","x_late":"시스템 관리 홈 페이지는 성능, 고장, 진단, 구성 및 소프트웨어 변경 관리를 포함한 통합 관리 기능을 강조한 단일 서버 관리용 통합 뷰를 제공합니다."},{"lang":"cn","x_late":"通过 System Management Homepage，可以统一查看单个服务器管理，特别是综合管理功能，包括性能、故障、安全性、诊断、配置及软件更改管理。"},{"lang":"ja","x_late":"System Management Homepageは、パフォーマンス、障害、セキュリティ、診断、コンフィギュレーション、およびソフトウェアの変更管理を含む統合された管理機能をハイライトする、シングル サーバー管理のための集約した画面を提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[{"lang":"en","x_late":"<p>As per SMH EOL terms, future patch releases will continue to provide fixes for security vulnerabilities &amp; might not provide support to any new OS or Browser.</p>\n"},{"lang":"ja","x_late":"<p>SMH EOLの利用規約によれば、将来のパッチリリースは安全上の脆弱性の解決策の提供を続けます、&新しい OSまたはブラウザーのサポートは提供しません。</p>\n"}],"files":[{"bytes":"14898392","datemodified":"2020-07-13T13:46:12","file_list":["./etc/opt/hp/sslshare","./opt/hp","./opt/hp/hpsmh","./opt/hp/hpsmh/bin","./opt/hp/hpsmh/bin/openssl","./opt/hp/hpsmh/bin/rotatelogs","./opt/hp/hpsmh/bin/smhlogreader","./opt/hp/hpsmh/certs","./opt/hp/hpsmh/conf","./opt/hp/hpsmh/conf/extra","./opt/hp/hpsmh/conf/extra/httpd-autoindex.conf","./opt/hp/hpsmh/conf/extra/httpd-dav.conf","./opt/hp/hpsmh/conf/extra/httpd-default.conf","./opt/hp/hpsmh/conf/extra/httpd-info.conf","./opt/hp/hpsmh/conf/extra/httpd-languages.conf","./opt/hp/hpsmh/conf/extra/httpd-manual.conf","./opt/hp/hpsmh/conf/extra/httpd-mpm.conf","./opt/hp/hpsmh/conf/extra/httpd-multilang-errordoc.conf","./opt/hp/hpsmh/conf/extra/httpd-ssl.conf","./opt/hp/hpsmh/conf/extra/httpd-userdir.conf","./opt/hp/hpsmh/conf/extra/httpd-vhosts.conf","./opt/hp/hpsmh/conf/magic","./opt/hp/hpsmh/conf/mime.types","./opt/hp/hpsmh/conf/original","./opt/hp/hpsmh/conf/original/extra","./opt/hp/hpsmh/conf/original/extra/httpd-autoindex.conf","./opt/hp/hpsmh/conf/original/extra/httpd-dav.conf","./opt/hp/hpsmh/conf/original/extra/httpd-default.conf","./opt/hp/hpsmh/conf/original/extra/httpd-info.conf","./opt/hp/hpsmh/conf/original/extra/httpd-languages.conf","./opt/hp/hpsmh/conf/original/extra/httpd-manual.conf","./opt/hp/hpsmh/conf/original/extra/httpd-mpm.conf","./opt/hp/hpsmh/conf/original/extra/httpd-multilang-errordoc.conf","./opt/hp/hpsmh/conf/original/extra/httpd-ssl.conf","./opt/hp/hpsmh/conf/original/extra/httpd-userdir.conf","./opt/hp/hpsmh/conf/original/extra/httpd-vhosts.conf","./opt/hp/hpsmh/conf/original/httpd.conf","./opt/hp/hpsmh/data","./opt/hp/hpsmh/data/cgi-bin","./opt/hp/hpsmh/data/cgi-bin/CGI","./opt/hp/hpsmh/data/cgi-bin/CGI.pm","./opt/hp/hpsmh/data/cgi-bin/CGI/Util.pm","./opt/hp/hpsmh/data/cgi-bin/IP.pm","./opt/hp/hpsmh/data/cgi-bin/SetSMHData.cgis","./opt/hp/hpsmh/data/help","./opt/hp/hpsmh/data/help/WEB_INF","./opt/hp/hpsmh/data/help/WEB_INF/cgi","./opt/hp/hpsmh/data/help/WEB_INF/cgi/var","./opt/hp/hpsmh/data/help/WEB_INF/cgi/var/en","./opt/hp/hpsmh/data/help/WEB_INF/cgi/var/en/smh","./opt/hp/hpsmh/data/help/WEB_INF/cgi/var/ja","./opt/hp/hpsmh/data/help/WEB_INF/cgi/var/ja/smh","./opt/hp/hpsmh/data/help/about.htm","./opt/hp/hpsmh/data/help/bsscnbar.js","./opt/hp/hpsmh/data/help/chphelp.htm","./opt/hp/hpsmh/data/help/default.css","./opt/hp/hpsmh/data/help/defns.css","./opt/hp/hpsmh/data/help/graphics","./opt/hp/hpsmh/data/help/graphics/iconCritical.png","./opt/hp/hpsmh/data/help/graphics/iconDisabled.png","./opt/hp/hpsmh/data/help/graphics/iconInfo.png","./opt/hp/hpsmh/data/help/graphics/iconNormal.png","./opt/hp/hpsmh/data/help/graphics/iconUnknown.png","./opt/hp/hpsmh/data/help/graphics/iconWarning.png","./opt/hp/hpsmh/data/help/graphics/major_15.png","./opt/hp/hpsmh/data/help/graphics/minor_15.png","./opt/hp/hpsmh/data/help/navpane2.htm","./opt/hp/hpsmh/data/help/nsdnsfix.jar","./opt/hp/hpsmh/data/help/smh","./opt/hp/hpsmh/data/help/smh/en","./opt/hp/hpsmh/data/help/smh/en/common","./opt/hp/hpsmh/data/help/smh/en/common/jquery","./opt/hp/hpsmh/data/help/smh/en/common/jquery/jquery-1.11.3.min.js","./opt/hp/hpsmh/data/help/smh/en/common/jquery/jquery-ui-1.8.2.custom.min.js","./opt/hp/hpsmh/data/help/smh/en/common/jquery/jquery.cookie.js","./opt/hp/hpsmh/data/help/smh/en/common/jquery/jquery.json-2.4.min.js","./opt/hp/hpsmh/data/help/smh/en/common/jquery/jstorage.js","./opt/hp/hpsmh/data/help/smh/en/common/jquery/theme-redmond","./opt/hp/hpsmh/data/help/smh/en/common/jquery/theme-redmond/images","./opt/hp/hpsmh/data/help/smh/en/common/jquery/theme-redmond/images/ui-anim_basic_16x16.gif","./opt/hp/hpsmh/data/help/smh/en/common/jquery/theme-redmond/images/ui-bg_flat_0_aaaaaa_40x100.png","./opt/hp/hpsmh/data/help/smh/en/common/jquery/theme-redmond/images/ui-bg_flat_55_fbec88_40x100.png","./opt/hp/hpsmh/data/help/smh/en/common/jquery/theme-redmond/images/ui-bg_glass_75_d0e5f5_1x400.png","./opt/hp/hpsmh/data/help/smh/en/common/jquery/theme-redmond/images/ui-bg_glass_85_dfeffc_1x400.png","./opt/hp/hpsmh/data/help/smh/en/common/jquery/theme-redmond/images/ui-bg_glass_95_fef1ec_1x400.png","./opt/hp/hpsmh/data/help/smh/en/common/jquery/theme-redmond/images/ui-bg_gloss-wave_55_5c9ccc_500x100.png","./opt/hp/hpsmh/data/help/smh/en/common/jquery/theme-redmond/images/ui-bg_inset-hard_100_f5f8f9_1x100.png","./opt/hp/hpsmh/data/help/smh/en/common/jquery/theme-redmond/images/ui-bg_inset-hard_100_fcfdfd_1x100.png","./opt/hp/hpsmh/data/help/smh/en/common/jquery/theme-redmond/images/ui-icons_217bc0_256x240.png","./opt/hp/hpsmh/data/help/smh/en/common/jquery/theme-redmond/images/ui-icons_2e83ff_256x240.png","./opt/hp/hpsmh/data/help/smh/en/common/jquery/theme-redmond/images/ui-icons_469bdd_256x240.png","./opt/hp/hpsmh/data/help/smh/en/common/jquery/theme-redmond/images/ui-icons_6da8d5_256x240.png","./opt/hp/hpsmh/data/help/smh/en/common/jquery/theme-redmond/images/ui-icons_cd0a0a_256x240.png","./opt/hp/hpsmh/data/help/smh/en/common/jquery/theme-redmond/images/ui-icons_d8e7f3_256x240.png","./opt/hp/hpsmh/data/help/smh/en/common/jquery/theme-redmond/images/ui-icons_f9bd01_256x240.png","./opt/hp/hpsmh/data/help/smh/en/common/jquery/theme-redmond/jquery-ui-1.8.2.custom.css","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/images","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/images/file.gif","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/images/folder-closed.gif","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/images/folder-closed2.gif","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/images/folder.gif","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/images/folder2.gif","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/images/minus.gif","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/images/plus.gif","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/images/treeview-black-line.gif","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/images/treeview-black.gif","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/images/treeview-default-line.gif","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/images/treeview-default.gif","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/images/treeview-famfamfam-line.gif","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/images/treeview-famfamfam.gif","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/images/treeview-gray-line.gif","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/images/treeview-gray.gif","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/images/treeview-red-line.gif","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/images/treeview-red.gif","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/jquery.treeview.async.js","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/jquery.treeview.css","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/jquery.treeview.js","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/jquery.treeview.min.js","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/jquery.treeview.pack.js","./opt/hp/hpsmh/data/help/smh/en/content","./opt/hp/hpsmh/data/help/smh/en/content/Sys-legal.html","./opt/hp/hpsmh/data/help/smh/en/content/bk01-toc.html","./opt/hp/hpsmh/data/help/smh/en/content/book.html","./opt/hp/hpsmh/data/help/smh/en/content/doc-feedback.html","./opt/hp/hpsmh/data/help/smh/en/content/ess_nav_frame.html","./opt/hp/hpsmh/data/help/smh/en/content/images","./opt/hp/hpsmh/data/help/smh/en/content/images/callouts","./opt/hp/hpsmh/data/help/smh/en/content/images/callouts/1.gif","./opt/hp/hpsmh/data/help/smh/en/content/images/callouts/1.png","./opt/hp/hpsmh/data/help/smh/en/content/images/callouts/10.gif","./opt/hp/hpsmh/data/help/smh/en/content/images/callouts/10.png","./opt/hp/hpsmh/data/help/smh/en/content/images/callouts/2.gif","./opt/hp/hpsmh/data/help/smh/en/content/images/callouts/2.png","./opt/hp/hpsmh/data/help/smh/en/content/images/callouts/3.gif","./opt/hp/hpsmh/data/help/smh/en/content/images/callouts/3.png","./opt/hp/hpsmh/data/help/smh/en/content/images/callouts/4.gif","./opt/hp/hpsmh/data/help/smh/en/content/images/callouts/4.png","./opt/hp/hpsmh/data/help/smh/en/content/images/callouts/5.gif","./opt/hp/hpsmh/data/help/smh/en/content/images/callouts/5.png","./opt/hp/hpsmh/data/help/smh/en/content/images/callouts/6.gif","./opt/hp/hpsmh/data/help/smh/en/content/images/callouts/6.png","./opt/hp/hpsmh/data/help/smh/en/content/images/callouts/7.gif","./opt/hp/hpsmh/data/help/smh/en/content/images/callouts/7.png","./opt/hp/hpsmh/data/help/smh/en/content/images/callouts/8.gif","./opt/hp/hpsmh/data/help/smh/en/content/images/callouts/8.png","./opt/hp/hpsmh/data/help/smh/en/content/images/callouts/9.gif","./opt/hp/hpsmh/data/help/smh/en/content/images/callouts/9.png","./opt/hp/hpsmh/data/help/smh/en/content/images/caution.gif","./opt/hp/hpsmh/data/help/smh/en/content/images/caution.png","./opt/hp/hpsmh/data/help/smh/en/content/images/cautionsm.gif","./opt/hp/hpsmh/data/help/smh/en/content/images/closed_book.jpg","./opt/hp/hpsmh/data/help/smh/en/content/images/collasped_closed_book_icon.jpg","./opt/hp/hpsmh/data/help/smh/en/content/images/draft.png","./opt/hp/hpsmh/data/help/smh/en/content/images/expanded_open_book_icon.jpg","./opt/hp/hpsmh/data/help/smh/en/content/images/graphics","./opt/hp/hpsmh/data/help/smh/en/content/images/graphics/iconCritical.png","./opt/hp/hpsmh/data/help/smh/en/content/images/graphics/iconDisabled.png","./opt/hp/hpsmh/data/help/smh/en/content/images/graphics/iconInfo.png","./opt/hp/hpsmh/data/help/smh/en/content/images/graphics/iconNormal.png","./opt/hp/hpsmh/data/help/smh/en/content/images/graphics/iconToolsUtilities.png","./opt/hp/hpsmh/data/help/smh/en/content/images/graphics/iconUnknown.png","./opt/hp/hpsmh/data/help/smh/en/content/images/graphics/iconWarning.png","./opt/hp/hpsmh/data/help/smh/en/content/images/graphics/major_15.png","./opt/hp/hpsmh/data/help/smh/en/content/images/graphics/minor_15.png","./opt/hp/hpsmh/data/help/smh/en/content/images/hp_small_sig.gif","./opt/hp/hpsmh/data/help/smh/en/content/images/hpesm_pri_blk_pos_rgb.png","./opt/hp/hpsmh/data/help/smh/en/content/images/important.gif","./opt/hp/hpsmh/data/help/smh/en/content/images/important.png","./opt/hp/hpsmh/data/help/smh/en/content/images/importantsm.gif","./opt/hp/hpsmh/data/help/smh/en/content/images/logo_sm.png","./opt/hp/hpsmh/data/help/smh/en/content/images/note.gif","./opt/hp/hpsmh/data/help/smh/en/content/images/note.png","./opt/hp/hpsmh/data/help/smh/en/content/images/notesm.gif","./opt/hp/hpsmh/data/help/smh/en/content/images/open_book.jpg","./opt/hp/hpsmh/data/help/smh/en/content/images/spacer.gif","./opt/hp/hpsmh/data/help/smh/en/content/images/tip.gif","./opt/hp/hpsmh/data/help/smh/en/content/images/tip.png","./opt/hp/hpsmh/data/help/smh/en/content/images/tipsm.gif","./opt/hp/hpsmh/data/help/smh/en/content/images/topic_page.jpg","./opt/hp/hpsmh/data/help/smh/en/content/images/warning.gif","./opt/hp/hpsmh/data/help/smh/en/content/images/warning.png","./opt/hp/hpsmh/data/help/smh/en/content/images/warningsm.gif","./opt/hp/hpsmh/data/help/smh/en/content/index.html","./opt/hp/hpsmh/data/help/smh/en/content/ix01.html","./opt/hp/hpsmh/data/help/smh/en/content/navheader.html","./opt/hp/hpsmh/data/help/smh/en/content/search","./opt/hp/hpsmh/data/help/smh/en/content/search-01.html","./opt/hp/hpsmh/data/help/smh/en/content/search/encoder.js","./opt/hp/hpsmh/data/help/smh/en/content/search/htmlFileInfoList.js","./opt/hp/hpsmh/data/help/smh/en/content/search/htmlFileList.js","./opt/hp/hpsmh/data/help/smh/en/content/search/index-1.js","./opt/hp/hpsmh/data/help/smh/en/content/search/index-2.js","./opt/hp/hpsmh/data/help/smh/en/content/search/index-3.js","./opt/hp/hpsmh/data/help/smh/en/content/search/nwSearchFnt.js","./opt/hp/hpsmh/data/help/smh/en/content/search/nwSearchFnt_asian.js","./opt/hp/hpsmh/data/help/smh/en/content/smh-helppage.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-home.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-logs-errlog.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-logs-smhpLog.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-logs.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-nav.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-p-pages.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-prod.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-set-credits.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-set-data-source.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-set-security.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-set-snmp-config.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-set-ui-options.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-set-uiproperties.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-set-user-preferences.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-set.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-ss-IPBinding.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-ss-IPResLogin.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-ss-anonAccess.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-ss-kerberos-users.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-ss-multihomedCert.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-ss-port.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-ss-port2301.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-ss-serverCert.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-ss-timeouts.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-ss-trustMode.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-ss-trustedServers.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-ss-userGroups.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-start-autoImport.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-start-firewallSettings.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-start-login.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-start-logout.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-start.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-support-lang.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-support.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-tasks.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-webapps.html","./opt/hp/hpsmh/data/help/smh/en/content/styles.css","./opt/hp/hpsmh/data/help/smh/en/content/support.html","./opt/hp/hpsmh/data/help/smh/en/content/sys-glossary.html","./opt/hp/hpsmh/data/help/smh/en/content/sys-help.html","./opt/hp/hpsmh/data/help/smh/en/graphics","./opt/hp/hpsmh/data/help/smh/en/graphics/iconCritical.png","./opt/hp/hpsmh/data/help/smh/en/graphics/iconDisabled.png","./opt/hp/hpsmh/data/help/smh/en/graphics/iconInfo.png","./opt/hp/hpsmh/data/help/smh/en/graphics/iconNormal.png","./opt/hp/hpsmh/data/help/smh/en/graphics/iconUnknown.png","./opt/hp/hpsmh/data/help/smh/en/graphics/iconWarning.png","./opt/hp/hpsmh/data/help/smh/en/graphics/major_15.png","./opt/hp/hpsmh/data/help/smh/en/graphics/minor_15.png","./opt/hp/hpsmh/data/help/smh/en/index-terms.xml","./opt/hp/hpsmh/data/help/smh/en/index.html","./opt/hp/hpsmh/data/help/smh/en/smh-helppage.html","./opt/hp/hpsmh/data/help/smh/en/smh-home.html","./opt/hp/hpsmh/data/help/smh/en/smh-logs-errlog.html","./opt/hp/hpsmh/data/help/smh/en/smh-logs-smhpLog.html","./opt/hp/hpsmh/data/help/smh/en/smh-logs.html","./opt/hp/hpsmh/data/help/smh/en/smh-nav.html","./opt/hp/hpsmh/data/help/smh/en/smh-p-pages.html","./opt/hp/hpsmh/data/help/smh/en/smh-prod.html","./opt/hp/hpsmh/data/help/smh/en/smh-set-credits.html","./opt/hp/hpsmh/data/help/smh/en/smh-set-data-source.html","./opt/hp/hpsmh/data/help/smh/en/smh-set-security.html","./opt/hp/hpsmh/data/help/smh/en/smh-set-snmp-config.html","./opt/hp/hpsmh/data/help/smh/en/smh-set-ui-options.html","./opt/hp/hpsmh/data/help/smh/en/smh-set-uiproperties.html","./opt/hp/hpsmh/data/help/smh/en/smh-set-user-preferences.html","./opt/hp/hpsmh/data/help/smh/en/smh-set.html","./opt/hp/hpsmh/data/help/smh/en/smh-ss-IPBinding.html","./opt/hp/hpsmh/data/help/smh/en/smh-ss-IPResLogin.html","./opt/hp/hpsmh/data/help/smh/en/smh-ss-anonAccess.html","./opt/hp/hpsmh/data/help/smh/en/smh-ss-kerberos-users.html","./opt/hp/hpsmh/data/help/smh/en/smh-ss-multihomedCert.html","./opt/hp/hpsmh/data/help/smh/en/smh-ss-port.html","./opt/hp/hpsmh/data/help/smh/en/smh-ss-port2301.html","./opt/hp/hpsmh/data/help/smh/en/smh-ss-serverCert.html","./opt/hp/hpsmh/data/help/smh/en/smh-ss-timeouts.html","./opt/hp/hpsmh/data/help/smh/en/smh-ss-trustMode.html","./opt/hp/hpsmh/data/help/smh/en/smh-ss-trustedServers.html","./opt/hp/hpsmh/data/help/smh/en/smh-ss-userGroups.html","./opt/hp/hpsmh/data/help/smh/en/smh-start-autoImport.html","./opt/hp/hpsmh/data/help/smh/en/smh-start-firewallSettings.html","./opt/hp/hpsmh/data/help/smh/en/smh-start-login.html","./opt/hp/hpsmh/data/help/smh/en/smh-start-logout.html","./opt/hp/hpsmh/data/help/smh/en/smh-start.html","./opt/hp/hpsmh/data/help/smh/en/smh-support-lang.html","./opt/hp/hpsmh/data/help/smh/en/smh-support.html","./opt/hp/hpsmh/data/help/smh/en/smh-tasks.html","./opt/hp/hpsmh/data/help/smh/en/smh-webapps.html","./opt/hp/hpsmh/data/help/smh/en/structure.xml","./opt/hp/hpsmh/data/help/smh/en/sys-glossary.html","./opt/hp/hpsmh/data/help/smh/en/sys-help.html","./opt/hp/hpsmh/data/help/smh/en/sys-index.html","./opt/hp/hpsmh/data/help/smh/en/sys-legal.html","./opt/hp/hpsmh/data/help/smh/en/sys-map.properties","./opt/hp/hpsmh/data/help/smh/en/sys-toc.html","./opt/hp/hpsmh/data/help/smh/en/sys-unavailable.html","./opt/hp/hpsmh/data/help/smh/en/topics.xml","./opt/hp/hpsmh/data/help/smh/ja","./opt/hp/hpsmh/data/help/smh/ja/common","./opt/hp/hpsmh/data/help/smh/ja/common/jquery","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/jquery-1.4.2.min.js","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/jquery-ui-1.8.2.custom.min.js","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/jquery.cookie.js","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/jquery.json-2.4.min.js","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/jstorage.js","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/theme-redmond","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/theme-redmond/images","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/theme-redmond/images/ui-anim_basic_16x16.gif","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/theme-redmond/images/ui-bg_flat_0_aaaaaa_40x100.png","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/theme-redmond/images/ui-bg_flat_55_fbec88_40x100.png","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/theme-redmond/images/ui-bg_glass_75_d0e5f5_1x400.png","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/theme-redmond/images/ui-bg_glass_85_dfeffc_1x400.png","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/theme-redmond/images/ui-bg_glass_95_fef1ec_1x400.png","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/theme-redmond/images/ui-bg_gloss-wave_55_5c9ccc_500x100.png","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/theme-redmond/images/ui-bg_inset-hard_100_f5f8f9_1x100.png","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/theme-redmond/images/ui-bg_inset-hard_100_fcfdfd_1x100.png","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/theme-redmond/images/ui-icons_217bc0_256x240.png","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/theme-redmond/images/ui-icons_2e83ff_256x240.png","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/theme-redmond/images/ui-icons_469bdd_256x240.png","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/theme-redmond/images/ui-icons_6da8d5_256x240.png","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/theme-redmond/images/ui-icons_cd0a0a_256x240.png","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/theme-redmond/images/ui-icons_d8e7f3_256x240.png","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/theme-redmond/images/ui-icons_f9bd01_256x240.png","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/theme-redmond/jquery-ui-1.8.2.custom.css","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/images","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/images/file.gif","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/images/folder-closed.gif","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/images/folder-closed2.gif","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/images/folder.gif","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/images/folder2.gif","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/images/minus.gif","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/images/plus.gif","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/images/treeview-black-line.gif","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/images/treeview-black.gif","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/images/treeview-default-line.gif","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/images/treeview-default.gif","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/images/treeview-famfamfam-line.gif","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/images/treeview-famfamfam.gif","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/images/treeview-gray-line.gif","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/images/treeview-gray.gif","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/images/treeview-red-line.gif","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/images/treeview-red.gif","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/jquery.treeview.async.js","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/jquery.treeview.css","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/jquery.treeview.js","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/jquery.treeview.min.js","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/jquery.treeview.pack.js","./opt/hp/hpsmh/data/help/smh/ja/common/main.js","./opt/hp/hpsmh/data/help/smh/ja/common/webhelp.js","./opt/hp/hpsmh/data/help/smh/ja/content","./opt/hp/hpsmh/data/help/smh/ja/content/Sys-legal.html","./opt/hp/hpsmh/data/help/smh/ja/content/bk01-toc.html","./opt/hp/hpsmh/data/help/smh/ja/content/book.html","./opt/hp/hpsmh/data/help/smh/ja/content/ess_nav_frame.html","./opt/hp/hpsmh/data/help/smh/ja/content/images","./opt/hp/hpsmh/data/help/smh/ja/content/images/callouts","./opt/hp/hpsmh/data/help/smh/ja/content/images/callouts/1.gif","./opt/hp/hpsmh/data/help/smh/ja/content/images/callouts/1.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/callouts/10.gif","./opt/hp/hpsmh/data/help/smh/ja/content/images/callouts/10.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/callouts/2.gif","./opt/hp/hpsmh/data/help/smh/ja/content/images/callouts/2.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/callouts/3.gif","./opt/hp/hpsmh/data/help/smh/ja/content/images/callouts/3.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/callouts/4.gif","./opt/hp/hpsmh/data/help/smh/ja/content/images/callouts/4.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/callouts/5.gif","./opt/hp/hpsmh/data/help/smh/ja/content/images/callouts/5.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/callouts/6.gif","./opt/hp/hpsmh/data/help/smh/ja/content/images/callouts/6.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/callouts/7.gif","./opt/hp/hpsmh/data/help/smh/ja/content/images/callouts/7.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/callouts/8.gif","./opt/hp/hpsmh/data/help/smh/ja/content/images/callouts/8.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/callouts/9.gif","./opt/hp/hpsmh/data/help/smh/ja/content/images/callouts/9.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/caution.gif","./opt/hp/hpsmh/data/help/smh/ja/content/images/caution.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/cautionsm.gif","./opt/hp/hpsmh/data/help/smh/ja/content/images/closed_book.jpg","./opt/hp/hpsmh/data/help/smh/ja/content/images/collasped_closed_book_icon.jpg","./opt/hp/hpsmh/data/help/smh/ja/content/images/draft.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/expanded_open_book_icon.jpg","./opt/hp/hpsmh/data/help/smh/ja/content/images/graphics","./opt/hp/hpsmh/data/help/smh/ja/content/images/graphics/iconCritical.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/graphics/iconDisabled.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/graphics/iconInfo.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/graphics/iconNormal.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/graphics/iconToolsUtilities.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/graphics/iconUnknown.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/graphics/iconWarning.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/graphics/major_15.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/graphics/minor_15.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/hp_small_sig.gif","./opt/hp/hpsmh/data/help/smh/ja/content/images/important.gif","./opt/hp/hpsmh/data/help/smh/ja/content/images/important.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/importantsm.gif","./opt/hp/hpsmh/data/help/smh/ja/content/images/logo.jpg","./opt/hp/hpsmh/data/help/smh/ja/content/images/logo_sm.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/note.gif","./opt/hp/hpsmh/data/help/smh/ja/content/images/note.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/notesm.gif","./opt/hp/hpsmh/data/help/smh/ja/content/images/open_book.jpg","./opt/hp/hpsmh/data/help/smh/ja/content/images/spacer.gif","./opt/hp/hpsmh/data/help/smh/ja/content/images/tip.gif","./opt/hp/hpsmh/data/help/smh/ja/content/images/tip.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/tipsm.gif","./opt/hp/hpsmh/data/help/smh/ja/content/images/topic_page.jpg","./opt/hp/hpsmh/data/help/smh/ja/content/images/warning.gif","./opt/hp/hpsmh/data/help/smh/ja/content/images/warning.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/warningsm.gif","./opt/hp/hpsmh/data/help/smh/ja/content/index.html","./opt/hp/hpsmh/data/help/smh/ja/content/ix01.html","./opt/hp/hpsmh/data/help/smh/ja/content/navheader.html","./opt/hp/hpsmh/data/help/smh/ja/content/search","./opt/hp/hpsmh/data/help/smh/ja/content/search-01.html","./opt/hp/hpsmh/data/help/smh/ja/content/search/encoder.js","./opt/hp/hpsmh/data/help/smh/ja/content/search/htmlFileInfoList.js","./opt/hp/hpsmh/data/help/smh/ja/content/search/htmlFileList.js","./opt/hp/hpsmh/data/help/smh/ja/content/search/index-1.js","./opt/hp/hpsmh/data/help/smh/ja/content/search/index-2.js","./opt/hp/hpsmh/data/help/smh/ja/content/search/index-3.js","./opt/hp/hpsmh/data/help/smh/ja/content/search/nwSearchFnt.js","./opt/hp/hpsmh/data/help/smh/ja/content/search/nwSearchFnt_asian.js","./opt/hp/hpsmh/data/help/smh/ja/content/search/stemmers","./opt/hp/hpsmh/data/help/smh/ja/content/smh-helppage.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-home.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-logs-errlog.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-logs-smhpLog.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-logs.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-nav.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-p-pages.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-prod.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-set-credits.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-set-data-source.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-set-security.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-set-snmp-config.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-set-ui-options.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-set-uiproperties.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-set-user-preferences.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-set.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-ss-IPBinding.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-ss-IPResLogin.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-ss-anonAccess.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-ss-kerberos-users.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-ss-multihomedCert.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-ss-port.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-ss-port2301.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-ss-serverCert.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-ss-timeouts.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-ss-trustMode.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-ss-trustedServers.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-ss-userGroups.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-start-autoImport.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-start-firewallSettings.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-start-login.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-start-logout.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-start.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-support-lang.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-support.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-tasks.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-webapps.html","./opt/hp/hpsmh/data/help/smh/ja/content/styles.css","./opt/hp/hpsmh/data/help/smh/ja/content/support.html","./opt/hp/hpsmh/data/help/smh/ja/content/sys-glossary.html","./opt/hp/hpsmh/data/help/smh/ja/content/sys-help.html","./opt/hp/hpsmh/data/help/smh/ja/graphics","./opt/hp/hpsmh/data/help/smh/ja/graphics/iconCritical.png","./opt/hp/hpsmh/data/help/smh/ja/graphics/iconDisabled.png","./opt/hp/hpsmh/data/help/smh/ja/graphics/iconInfo.png","./opt/hp/hpsmh/data/help/smh/ja/graphics/iconNormal.png","./opt/hp/hpsmh/data/help/smh/ja/graphics/iconUnknown.png","./opt/hp/hpsmh/data/help/smh/ja/graphics/iconWarning.png","./opt/hp/hpsmh/data/help/smh/ja/graphics/major_15.png","./opt/hp/hpsmh/data/help/smh/ja/graphics/minor_15.png","./opt/hp/hpsmh/data/help/smh/ja/index-terms.xml","./opt/hp/hpsmh/data/help/smh/ja/index.html","./opt/hp/hpsmh/data/help/smh/ja/smh-helppage.html","./opt/hp/hpsmh/data/help/smh/ja/smh-home.html","./opt/hp/hpsmh/data/help/smh/ja/smh-logs-errlog.html","./opt/hp/hpsmh/data/help/smh/ja/smh-logs-smhpLog.html","./opt/hp/hpsmh/data/help/smh/ja/smh-logs.html","./opt/hp/hpsmh/data/help/smh/ja/smh-nav.html","./opt/hp/hpsmh/data/help/smh/ja/smh-p-pages.html","./opt/hp/hpsmh/data/help/smh/ja/smh-prod.html","./opt/hp/hpsmh/data/help/smh/ja/smh-set-credits.html","./opt/hp/hpsmh/data/help/smh/ja/smh-set-data-source.html","./opt/hp/hpsmh/data/help/smh/ja/smh-set-security.html","./opt/hp/hpsmh/data/help/smh/ja/smh-set-snmp-config.html","./opt/hp/hpsmh/data/help/smh/ja/smh-set-ui-options.html","./opt/hp/hpsmh/data/help/smh/ja/smh-set-uiproperties.html","./opt/hp/hpsmh/data/help/smh/ja/smh-set-user-preferences.html","./opt/hp/hpsmh/data/help/smh/ja/smh-set.html","./opt/hp/hpsmh/data/help/smh/ja/smh-ss-IPBinding.html","./opt/hp/hpsmh/data/help/smh/ja/smh-ss-IPResLogin.html","./opt/hp/hpsmh/data/help/smh/ja/smh-ss-anonAccess.html","./opt/hp/hpsmh/data/help/smh/ja/smh-ss-kerberos-users.html","./opt/hp/hpsmh/data/help/smh/ja/smh-ss-multihomedCert.html","./opt/hp/hpsmh/data/help/smh/ja/smh-ss-port.html","./opt/hp/hpsmh/data/help/smh/ja/smh-ss-port2301.html","./opt/hp/hpsmh/data/help/smh/ja/smh-ss-serverCert.html","./opt/hp/hpsmh/data/help/smh/ja/smh-ss-timeouts.html","./opt/hp/hpsmh/data/help/smh/ja/smh-ss-trustMode.html","./opt/hp/hpsmh/data/help/smh/ja/smh-ss-trustedServers.html","./opt/hp/hpsmh/data/help/smh/ja/smh-ss-userGroups.html","./opt/hp/hpsmh/data/help/smh/ja/smh-start-autoImport.html","./opt/hp/hpsmh/data/help/smh/ja/smh-start-firewallSettings.html","./opt/hp/hpsmh/data/help/smh/ja/smh-start-login.html","./opt/hp/hpsmh/data/help/smh/ja/smh-start-logout.html","./opt/hp/hpsmh/data/help/smh/ja/smh-start.html","./opt/hp/hpsmh/data/help/smh/ja/smh-support-lang.html","./opt/hp/hpsmh/data/help/smh/ja/smh-support.html","./opt/hp/hpsmh/data/help/smh/ja/smh-tasks.html","./opt/hp/hpsmh/data/help/smh/ja/smh-webapps.html","./opt/hp/hpsmh/data/help/smh/ja/structure.xml","./opt/hp/hpsmh/data/help/smh/ja/sys-glossary.html","./opt/hp/hpsmh/data/help/smh/ja/sys-help.html","./opt/hp/hpsmh/data/help/smh/ja/sys-index.html","./opt/hp/hpsmh/data/help/smh/ja/sys-legal.html","./opt/hp/hpsmh/data/help/smh/ja/sys-map.properties","./opt/hp/hpsmh/data/help/smh/ja/sys-toc.html","./opt/hp/hpsmh/data/help/smh/ja/sys-unavailable.html","./opt/hp/hpsmh/data/help/smh/ja/topics.xml","./opt/hp/hpsmh/data/help/smh/zh","./opt/hp/hpsmh/data/help/smh/zh/common","./opt/hp/hpsmh/data/help/smh/zh/common/jquery","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/jquery-1.4.2.min.js","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/jquery-ui-1.8.2.custom.min.js","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/jquery.cookie.js","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/jquery.json-2.4.min.js","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/jstorage.js","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/theme-redmond","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/theme-redmond/images","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/theme-redmond/images/ui-anim_basic_16x16.gif","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/theme-redmond/images/ui-bg_flat_0_aaaaaa_40x100.png","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/theme-redmond/images/ui-bg_flat_55_fbec88_40x100.png","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/theme-redmond/images/ui-bg_glass_75_d0e5f5_1x400.png","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/theme-redmond/images/ui-bg_glass_85_dfeffc_1x400.png","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/theme-redmond/images/ui-bg_glass_95_fef1ec_1x400.png","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/theme-redmond/images/ui-bg_gloss-wave_55_5c9ccc_500x100.png","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/theme-redmond/images/ui-bg_inset-hard_100_f5f8f9_1x100.png","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/theme-redmond/images/ui-bg_inset-hard_100_fcfdfd_1x100.png","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/theme-redmond/images/ui-icons_217bc0_256x240.png","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/theme-redmond/images/ui-icons_2e83ff_256x240.png","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/theme-redmond/images/ui-icons_469bdd_256x240.png","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/theme-redmond/images/ui-icons_6da8d5_256x240.png","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/theme-redmond/images/ui-icons_cd0a0a_256x240.png","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/theme-redmond/images/ui-icons_d8e7f3_256x240.png","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/theme-redmond/images/ui-icons_f9bd01_256x240.png","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/theme-redmond/jquery-ui-1.8.2.custom.css","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/images","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/images/file.gif","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/images/folder-closed.gif","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/images/folder-closed2.gif","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/images/folder.gif","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/images/folder2.gif","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/images/minus.gif","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/images/plus.gif","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/images/treeview-black-line.gif","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/images/treeview-black.gif","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/images/treeview-default-line.gif","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/images/treeview-default.gif","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/images/treeview-famfamfam-line.gif","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/images/treeview-famfamfam.gif","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/images/treeview-gray-line.gif","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/images/treeview-gray.gif","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/images/treeview-red-line.gif","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/images/treeview-red.gif","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/jquery.treeview.async.js","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/jquery.treeview.css","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/jquery.treeview.js","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/jquery.treeview.min.js","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/jquery.treeview.pack.js","./opt/hp/hpsmh/data/help/smh/zh/common/main.js","./opt/hp/hpsmh/data/help/smh/zh/common/webhelp.js","./opt/hp/hpsmh/data/help/smh/zh/content","./opt/hp/hpsmh/data/help/smh/zh/content/Sys-legal.html","./opt/hp/hpsmh/data/help/smh/zh/content/bk01-toc.html","./opt/hp/hpsmh/data/help/smh/zh/content/book.html","./opt/hp/hpsmh/data/help/smh/zh/content/ess_nav_frame.html","./opt/hp/hpsmh/data/help/smh/zh/content/images","./opt/hp/hpsmh/data/help/smh/zh/content/images/callouts","./opt/hp/hpsmh/data/help/smh/zh/content/images/callouts/1.gif","./opt/hp/hpsmh/data/help/smh/zh/content/images/callouts/1.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/callouts/10.gif","./opt/hp/hpsmh/data/help/smh/zh/content/images/callouts/10.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/callouts/2.gif","./opt/hp/hpsmh/data/help/smh/zh/content/images/callouts/2.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/callouts/3.gif","./opt/hp/hpsmh/data/help/smh/zh/content/images/callouts/3.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/callouts/4.gif","./opt/hp/hpsmh/data/help/smh/zh/content/images/callouts/4.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/callouts/5.gif","./opt/hp/hpsmh/data/help/smh/zh/content/images/callouts/5.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/callouts/6.gif","./opt/hp/hpsmh/data/help/smh/zh/content/images/callouts/6.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/callouts/7.gif","./opt/hp/hpsmh/data/help/smh/zh/content/images/callouts/7.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/callouts/8.gif","./opt/hp/hpsmh/data/help/smh/zh/content/images/callouts/8.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/callouts/9.gif","./opt/hp/hpsmh/data/help/smh/zh/content/images/callouts/9.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/caution.gif","./opt/hp/hpsmh/data/help/smh/zh/content/images/caution.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/cautionsm.gif","./opt/hp/hpsmh/data/help/smh/zh/content/images/closed_book.jpg","./opt/hp/hpsmh/data/help/smh/zh/content/images/collasped_closed_book_icon.jpg","./opt/hp/hpsmh/data/help/smh/zh/content/images/draft.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/expanded_open_book_icon.jpg","./opt/hp/hpsmh/data/help/smh/zh/content/images/graphics","./opt/hp/hpsmh/data/help/smh/zh/content/images/graphics/iconCritical.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/graphics/iconDisabled.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/graphics/iconInfo.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/graphics/iconNormal.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/graphics/iconToolsUtilities.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/graphics/iconUnknown.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/graphics/iconWarning.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/graphics/major_15.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/graphics/minor_15.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/hp_small_sig.gif","./opt/hp/hpsmh/data/help/smh/zh/content/images/important.gif","./opt/hp/hpsmh/data/help/smh/zh/content/images/important.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/importantsm.gif","./opt/hp/hpsmh/data/help/smh/zh/content/images/logo.jpg","./opt/hp/hpsmh/data/help/smh/zh/content/images/logo_sm.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/note.gif","./opt/hp/hpsmh/data/help/smh/zh/content/images/note.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/notesm.gif","./opt/hp/hpsmh/data/help/smh/zh/content/images/open_book.jpg","./opt/hp/hpsmh/data/help/smh/zh/content/images/spacer.gif","./opt/hp/hpsmh/data/help/smh/zh/content/images/tip.gif","./opt/hp/hpsmh/data/help/smh/zh/content/images/tip.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/tipsm.gif","./opt/hp/hpsmh/data/help/smh/zh/content/images/topic_page.jpg","./opt/hp/hpsmh/data/help/smh/zh/content/images/warning.gif","./opt/hp/hpsmh/data/help/smh/zh/content/images/warning.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/warningsm.gif","./opt/hp/hpsmh/data/help/smh/zh/content/index.html","./opt/hp/hpsmh/data/help/smh/zh/content/ix01.html","./opt/hp/hpsmh/data/help/smh/zh/content/navheader.html","./opt/hp/hpsmh/data/help/smh/zh/content/search","./opt/hp/hpsmh/data/help/smh/zh/content/search-01.html","./opt/hp/hpsmh/data/help/smh/zh/content/search/encoder.js","./opt/hp/hpsmh/data/help/smh/zh/content/search/htmlFileInfoList.js","./opt/hp/hpsmh/data/help/smh/zh/content/search/htmlFileList.js","./opt/hp/hpsmh/data/help/smh/zh/content/search/index-1.js","./opt/hp/hpsmh/data/help/smh/zh/content/search/index-2.js","./opt/hp/hpsmh/data/help/smh/zh/content/search/index-3.js","./opt/hp/hpsmh/data/help/smh/zh/content/search/nwSearchFnt.js","./opt/hp/hpsmh/data/help/smh/zh/content/search/nwSearchFnt_asian.js","./opt/hp/hpsmh/data/help/smh/zh/content/search/stemmers","./opt/hp/hpsmh/data/help/smh/zh/content/smh-helppage.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-home.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-logs-errlog.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-logs-smhpLog.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-logs.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-nav.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-p-pages.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-prod.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-set-credits.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-set-data-source.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-set-security.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-set-snmp-config.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-set-ui-options.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-set-uiproperties.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-set-user-preferences.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-set.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-ss-IPBinding.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-ss-IPResLogin.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-ss-anonAccess.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-ss-kerberos-users.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-ss-multihomedCert.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-ss-port.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-ss-port2301.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-ss-serverCert.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-ss-timeouts.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-ss-trustMode.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-ss-trustedServers.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-ss-userGroups.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-start-autoImport.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-start-firewallSettings.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-start-login.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-start-logout.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-start.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-support-lang.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-support.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-tasks.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-webapps.html","./opt/hp/hpsmh/data/help/smh/zh/content/styles.css","./opt/hp/hpsmh/data/help/smh/zh/content/support.html","./opt/hp/hpsmh/data/help/smh/zh/content/sys-glossary.html","./opt/hp/hpsmh/data/help/smh/zh/content/sys-help.html","./opt/hp/hpsmh/data/help/smh/zh/topics.xml","./opt/hp/hpsmh/data/help/webhelp.jar","./opt/hp/hpsmh/data/help/webhelp.res","./opt/hp/hpsmh/data/help/xidistyle","./opt/hp/hpsmh/data/help/xidistyle/3.1","./opt/hp/hpsmh/data/help/xidistyle/3.1/img","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_003366.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_006699.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_336666.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_336699.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_3399cc.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_666633.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_669999.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_6699cc.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_66ccff.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_993300.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_996600.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_996633.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_996666.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_999966.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_99cccc.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_99ccff.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_cc3333.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_cc6633.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_cc9933.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_cc9966.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_cc9999.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_cccc99.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_ff6600.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_ff6666.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_ff9900.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_ff9966.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_ff9999.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_ffcc66.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_ffcc99.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_ffcccc.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_nav_003366.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_nav_336699.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_nav_669966.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_nav_6699cc.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_nav_ffffff.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_sm_ffffff.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_th_ffffff.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/rarrow.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/blank-icon.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/corners","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/corners/bl_corner_10.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/corners/bl_corner_1010.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/corners/bl_navcorner_20.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/corners/br_corner_10.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/corners/br_corner_1010.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/corners/br_navcorner_20.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/corners/tl_corner_10.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/corners/tl_corner_1010.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/corners/tl_navcorner_20.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/corners/tr_corner_10.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/corners/tr_corner_1010.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/corners/tr_navcorner_20.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/blank.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/1.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/1.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/10.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/10.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/11.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/11.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/12.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/12.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/13.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/13.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/14.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/14.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/15.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/15.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/2.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/2.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/3.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/3.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/4.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/4.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/5.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/5.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/6.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/6.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/7.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/7.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/8.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/8.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/9.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/9.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/caution.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/caution.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/caution.tif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/draft.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/home.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/home.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/important.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/important.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/important.tif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/next.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/next.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/note.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/note.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/note.tif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/prev.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/prev.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/tip.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/tip.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/tip.tif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/toc-blank.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/toc-minus.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/toc-plus.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/up.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/up.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/warning.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/warning.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/warning.tif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/hpc60_arrow_submit.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/hpc60_leftnav_background.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/hpc60_topnav_hp_logo.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/icon_print.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/important.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/language","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/language/de.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/language/en.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/language/es.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/language/fr.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/language/it.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/language/ja.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/language/ko.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/language/zh_cn.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/language/zh_tw.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/logo.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/s.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/spacer.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/topgrey_30.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/js","./opt/hp/hpsmh/data/help/xidistyle/3.1/js/hpweb_country_pulldown.js","./opt/hp/hpsmh/data/help/xidistyle/3.1/js/hpweb_utilities.js","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/de","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/de/hpweb_styles_ns4.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/de/hpweb_styles_strd.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/de/hpweb_styles_win_ie.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/de/hpweb_styles_win_ie6.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/docbook.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/en","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/en/hpweb_styles_ns4.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/en/hpweb_styles_strd.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/en/hpweb_styles_win_ie.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/en/hpweb_styles_win_ie6.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/es","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/es/hpweb_styles_ns4.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/es/hpweb_styles_strd.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/es/hpweb_styles_win_ie.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/es/hpweb_styles_win_ie6.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/fr","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/fr/hpweb_styles_ns4.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/fr/hpweb_styles_strd.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/fr/hpweb_styles_win_ie.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/fr/hpweb_styles_win_ie6.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/it","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/it/hpweb_styles_ns4.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/it/hpweb_styles_strd.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/it/hpweb_styles_win_ie.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/it/hpweb_styles_win_ie6.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/ja","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/ja/hpweb_styles_ns4.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/ja/hpweb_styles_strd.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/ja/hpweb_styles_win_ie.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/ja/hpweb_styles_win_ie6.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/ko","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/ko/hpweb_styles_ns4.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/ko/hpweb_styles_strd.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/ko/hpweb_styles_win_ie.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/ko/hpweb_styles_win_ie6.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/zh_cn","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/zh_cn/hpweb_styles_ns4.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/zh_cn/hpweb_styles_strd.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/zh_cn/hpweb_styles_win_ie.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/zh_cn/hpweb_styles_win_ie6.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/zh_tw","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/zh_tw/hpweb_styles_ns4.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/zh_tw/hpweb_styles_strd.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/zh_tw/hpweb_styles_win_ie.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/zh_tw/hpweb_styles_win_ie6.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/us","./opt/hp/hpsmh/data/help/xidistyle/3.1/us/eng","./opt/hp/hpsmh/data/help/xidistyle/3.1/us/eng/img","./opt/hp/hpsmh/data/help/xidistyle/3.1/us/eng/img/top","./opt/hp/hpsmh/data/help/xidistyle/3.1/us/eng/img/top/buy_off.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/us/eng/img/top/buy_on.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/us/eng/img/top/country.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/us/eng/img/top/english.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/us/eng/img/top/english2.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/us/eng/img/top/home_off.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/us/eng/img/top/home_on.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/us/eng/img/top/prodserv_off.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/us/eng/img/top/prodserv_on.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/us/eng/img/top/solutions_off.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/us/eng/img/top/solutions_on.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/us/eng/img/top/support_off.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/us/eng/img/top/support_on.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2","./opt/hp/hpsmh/data/help/xidistyle/3.2/img","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_003366.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_006699.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_336666.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_336699.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_3399cc.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_666633.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_669999.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_6699cc.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_66ccff.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_993300.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_996600.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_996633.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_996666.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_999966.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_99cccc.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_99ccff.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_cc3333.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_cc6633.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_cc9933.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_cc9966.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_cc9999.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_cccc99.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_ff6600.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_ff6666.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_ff9900.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_ff9966.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_ff9999.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_ffcc66.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_ffcc99.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_ffcccc.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_nav_003366.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_nav_336699.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_nav_669966.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_nav_6699cc.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_nav_ffffff.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_sm_ffffff.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_th_ffffff.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/rarrow.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/blank-icon.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/corners","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/corners/bl_corner_10.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/corners/bl_corner_1010.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/corners/bl_navcorner_20.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/corners/br_corner_10.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/corners/br_corner_1010.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/corners/br_navcorner_20.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/corners/tl_corner_10.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/corners/tl_corner_1010.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/corners/tl_navcorner_20.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/corners/tr_corner_10.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/corners/tr_corner_1010.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/corners/tr_navcorner_20.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/blank.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/1.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/1.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/10.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/10.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/11.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/11.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/12.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/12.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/13.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/13.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/14.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/14.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/15.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/15.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/2.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/2.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/3.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/3.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/4.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/4.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/5.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/5.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/6.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/6.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/7.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/7.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/8.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/8.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/9.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/9.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/caution.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/caution.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/caution.svg","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/caution.tif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/draft.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/home.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/home.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/important.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/important.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/important.svg","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/important.tif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/next.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/next.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/note.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/note.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/note.svg","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/note.tif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/prev.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/prev.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/t-bullet.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/tip.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/tip.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/tip.svg","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/tip.tif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/toc-blank.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/toc-minus.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/toc-plus.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/up.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/up.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/warning.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/warning.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/warning.svg","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/warning.tif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/hpc60_arrow_submit.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/hpc60_leftnav_background.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/hpc60_topnav_hp_logo.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/icon_print.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/important.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/language","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/language/de.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/language/en.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/language/es.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/language/fr.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/language/it.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/language/ja.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/language/ko.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/language/zh_cn.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/language/zh_tw.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/logo.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/pdf_icon.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/s.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/s.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/spacer.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/topgrey_30.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/js","./opt/hp/hpsmh/data/help/xidistyle/3.2/js/hpweb_country_pulldown.js","./opt/hp/hpsmh/data/help/xidistyle/3.2/js/hpweb_utilities.js","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/de","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/de/hpweb_styles_ns4.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/de/hpweb_styles_strd.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/de/hpweb_styles_win_ie.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/de/hpweb_styles_win_ie6.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/docbook.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/en","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/en/hpweb_styles_ns4.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/en/hpweb_styles_strd.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/en/hpweb_styles_win_ie.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/en/hpweb_styles_win_ie6.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/es","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/es/hpweb_styles_ns4.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/es/hpweb_styles_strd.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/es/hpweb_styles_win_ie.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/es/hpweb_styles_win_ie6.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/fr","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/fr/hpweb_styles_ns4.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/fr/hpweb_styles_strd.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/fr/hpweb_styles_win_ie.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/fr/hpweb_styles_win_ie6.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/it","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/it/hpweb_styles_ns4.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/it/hpweb_styles_strd.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/it/hpweb_styles_win_ie.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/it/hpweb_styles_win_ie6.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/ja","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/ja/hpweb_styles_ns4.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/ja/hpweb_styles_strd.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/ja/hpweb_styles_win_ie.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/ja/hpweb_styles_win_ie6.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/ko","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/ko/hpweb_styles_ns4.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/ko/hpweb_styles_strd.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/ko/hpweb_styles_win_ie.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/ko/hpweb_styles_win_ie6.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/xididoc.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/zh_cn","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/zh_cn/hpweb_styles_ns4.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/zh_cn/hpweb_styles_strd.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/zh_cn/hpweb_styles_win_ie.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/zh_cn/hpweb_styles_win_ie6.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/zh_tw","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/zh_tw/hpweb_styles_ns4.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/zh_tw/hpweb_styles_strd.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/zh_tw/hpweb_styles_win_ie.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/zh_tw/hpweb_styles_win_ie6.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/css","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/css/aural.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/css/blue_theme.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/css/default.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/css/green_theme.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/css/magenta_theme.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/css/orange_theme.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/css/print.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/bullet.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/grey_panel_bg.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/icon_shortcut_arrow.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/icon_status_critical.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/icon_status_disabled.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/icon_status_informational.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/icon_status_major.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/icon_status_minor.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/icon_status_normal.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/icon_status_unknown.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/icon_status_warning.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/icon_tray_contract_u.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/icon_tray_expand_d.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/navbar_local_trigger_bg.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/navbar_local_trigger_over_bg.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/navbar_notch_left.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/navbar_notch_right.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/placeholder_identifier_icon.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/placeholder_masthead_photo_large.jpg","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/placeholder_masthead_photo_small.jpg","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/progress_bar_large.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/progress_bar_small.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/sorted_column_asc_bg.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/sorted_column_desc_bg.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/tab_set_bg.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/tab_set_secondary_bg.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/blue","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/blue/button_tree_contract.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/blue/button_tree_expand.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/blue/language","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/blue/language/de.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/blue/language/en.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/blue/language/es.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/blue/language/fr.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/blue/language/it.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/blue/language/ja.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/blue/language/ko.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/blue/language/zh_cn.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/blue/language/zh_tw.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/blue/logo_hp_largemasthead.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/blue/logo_hp_smallmasthead.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/blue/navbar_checkbox.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/blue/navbar_global_trigger_bg.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/blue/navbar_global_trigger_over_bg.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/blue/navbar_parent_bg.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/blue/navbar_parent_bg_over.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/blue/tab_right.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/blue/tab_secondary_right.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/green","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/green/button_tree_contract.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/green/button_tree_expand.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/green/language","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/green/language/de.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/green/language/en.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/green/language/es.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/green/language/fr.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/green/language/it.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/green/language/ja.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/green/language/ko.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/green/language/zh_cn.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/green/language/zh_tw.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/green/logo_hp_largemasthead.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/green/logo_hp_smallmasthead.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/green/navbar_checkbox.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/green/navbar_global_trigger_bg.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/green/navbar_global_trigger_over_bg.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/green/navbar_parent_bg.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/green/navbar_parent_bg_over.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/green/tab_right.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/green/tab_secondary_right.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/magenta","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/magenta/button_tree_contract.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/magenta/button_tree_expand.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/magenta/language","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/magenta/language/de.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/magenta/language/en.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/magenta/language/es.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/magenta/language/fr.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/magenta/language/it.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/magenta/language/ja.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/magenta/language/ko.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/magenta/language/zh_cn.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/magenta/language/zh_tw.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/magenta/logo_hp_largemasthead.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/magenta/logo_hp_smallmasthead.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/magenta/navbar_checkbox.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/magenta/navbar_global_trigger_bg.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/magenta/navbar_global_trigger_over_bg.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/magenta/navbar_parent_bg.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/magenta/navbar_parent_bg_over.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/magenta/tab_right.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/magenta/tab_secondary_right.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/orange","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/orange/button_tree_contract.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/orange/button_tree_expand.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/orange/language","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/orange/language/de.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/orange/language/en.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/orange/language/es.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/orange/language/fr.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/orange/language/it.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/orange/language/ja.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/orange/language/ko.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/orange/language/zh_cn.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/orange/language/zh_tw.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/orange/logo_hp_largemasthead.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/orange/logo_hp_smallmasthead.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/orange/navbar_checkbox.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/orange/navbar_global_trigger_bg.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/orange/navbar_global_trigger_over_bg.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/orange/navbar_parent_bg.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/orange/navbar_parent_bg_over.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/orange/tab_right.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/orange/tab_secondary_right.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/js","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/js/buttonManager.js","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/js/dropdownMenuManager.js","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/js/global.js","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/js/navigationControlManager.js","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/js/tabManager.js","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/js/tableManager.js","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/js/transferBoxManager.js","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/js/treeManager.js","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/js/treeTableManager.js","./opt/hp/hpsmh/data/help/xidistyle/3.2/us","./opt/hp/hpsmh/data/help/xidistyle/3.2/us/eng","./opt/hp/hpsmh/data/help/xidistyle/3.2/us/eng/img","./opt/hp/hpsmh/data/help/xidistyle/3.2/us/eng/img/top","./opt/hp/hpsmh/data/help/xidistyle/3.2/us/eng/img/top/buy_off.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/us/eng/img/top/buy_on.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/us/eng/img/top/country.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/us/eng/img/top/english.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/us/eng/img/top/english2.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/us/eng/img/top/home_off.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/us/eng/img/top/home_on.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/us/eng/img/top/prodserv_off.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/us/eng/img/top/prodserv_on.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/us/eng/img/top/solutions_off.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/us/eng/img/top/solutions_on.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/us/eng/img/top/support_off.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/us/eng/img/top/support_on.gif","./opt/hp/hpsmh/data/htdocs","./opt/hp/hpsmh/data/htdocs/addcert.php.en","./opt/hp/hpsmh/data/htdocs/agents.php","./opt/hp/hpsmh/data/htdocs/aiclogin.php.en","./opt/hp/hpsmh/data/htdocs/aiclogin_cert.php","./opt/hp/hpsmh/data/htdocs/chp.js.en","./opt/hp/hpsmh/data/htdocs/chpblank.htm","./opt/hp/hpsmh/data/htdocs/chpbrdg.php.en","./opt/hp/hpsmh/data/htdocs/chpdata.php.en","./opt/hp/hpsmh/data/htdocs/chphead.php.en","./opt/hp/hpsmh/data/htdocs/chpif.js","./opt/hp/hpsmh/data/htdocs/chplinkstrt.php","./opt/hp/hpsmh/data/htdocs/chpload.htm.en","./opt/hp/hpsmh/data/htdocs/chpstrt.php.en","./opt/hp/hpsmh/data/htdocs/chpview.php","./opt/hp/hpsmh/data/htdocs/cpqlogin.htm","./opt/hp/hpsmh/data/htdocs/cpqlogin.php.en","./opt/hp/hpsmh/data/htdocs/cpqopts.htm","./opt/hp/hpsmh/data/htdocs/cpqopts.php.en","./opt/hp/hpsmh/data/htdocs/credits.php.en","./opt/hp/hpsmh/data/htdocs/css","./opt/hp/hpsmh/data/htdocs/css/aural.css","./opt/hp/hpsmh/data/htdocs/css/blue_theme.css","./opt/hp/hpsmh/data/htdocs/css/common.css","./opt/hp/hpsmh/data/htdocs/css/common_ie.css","./opt/hp/hpsmh/data/htdocs/css/default.css","./opt/hp/hpsmh/data/htdocs/css/green_theme.css","./opt/hp/hpsmh/data/htdocs/css/home.css","./opt/hp/hpsmh/data/htdocs/css/index.css","./opt/hp/hpsmh/data/htdocs/css/logon.css","./opt/hp/hpsmh/data/htdocs/css/magenta_theme.css","./opt/hp/hpsmh/data/htdocs/css/orange_theme.css","./opt/hp/hpsmh/data/htdocs/css/print.css","./opt/hp/hpsmh/data/htdocs/custcert.php.en","./opt/hp/hpsmh/data/htdocs/custom_ui","./opt/hp/hpsmh/data/htdocs/custom_ui/README.txt","./opt/hp/hpsmh/data/htdocs/errlog.php.en","./opt/hp/hpsmh/data/htdocs/failed.htm","./opt/hp/hpsmh/data/htdocs/favicon.ico","./opt/hp/hpsmh/data/htdocs/groups.php.en","./opt/hp/hpsmh/data/htdocs/gsearch.php.en","./opt/hp/hpsmh/data/htdocs/images","./opt/hp/hpsmh/data/htdocs/images/blank.gif","./opt/hp/hpsmh/data/htdocs/images/bullet.gif","./opt/hp/hpsmh/data/htdocs/images/divider3d_horiz.gif","./opt/hp/hpsmh/data/htdocs/images/grey_panel_bg.gif","./opt/hp/hpsmh/data/htdocs/images/header_title.gif","./opt/hp/hpsmh/data/htdocs/images/hpInvent.gif","./opt/hp/hpsmh/data/htdocs/images/hpInvent.jpg","./opt/hp/hpsmh/data/htdocs/images/hp_logo_invert.gif","./opt/hp/hpsmh/data/htdocs/images/hpesm_spec_grn_rev_rgb.png","./opt/hp/hpsmh/data/htdocs/images/hplogo.gif","./opt/hp/hpsmh/data/htdocs/images/icon_bullet_list.gif","./opt/hp/hpsmh/data/htdocs/images/icon_shortcut_arrow.gif","./opt/hp/hpsmh/data/htdocs/images/icon_status_critical.gif","./opt/hp/hpsmh/data/htdocs/images/icon_status_disabled.gif","./opt/hp/hpsmh/data/htdocs/images/icon_status_informational.gif","./opt/hp/hpsmh/data/htdocs/images/icon_status_major.gif","./opt/hp/hpsmh/data/htdocs/images/icon_status_minor.gif","./opt/hp/hpsmh/data/htdocs/images/icon_status_normal.gif","./opt/hp/hpsmh/data/htdocs/images/icon_status_unknown.gif","./opt/hp/hpsmh/data/htdocs/images/icon_status_warning.gif","./opt/hp/hpsmh/data/htdocs/images/icon_tray_contract_u.gif","./opt/hp/hpsmh/data/htdocs/images/icon_tray_expand_d.gif","./opt/hp/hpsmh/data/htdocs/images/icons","./opt/hp/hpsmh/data/htdocs/images/icons/cpqopts.png","./opt/hp/hpsmh/data/htdocs/images/icons/custcert.png","./opt/hp/hpsmh/data/htdocs/images/icons/generic.png","./opt/hp/hpsmh/data/htdocs/images/icons/groups.png","./opt/hp/hpsmh/data/htdocs/images/icons/http_log.png","./opt/hp/hpsmh/data/htdocs/images/icons/ipbind.png","./opt/hp/hpsmh/data/htdocs/images/icons/iprstrct.png","./opt/hp/hpsmh/data/htdocs/images/icons/kerberos.png","./opt/hp/hpsmh/data/htdocs/images/icons/local.png","./opt/hp/hpsmh/data/htdocs/images/icons/overallStatus.png","./opt/hp/hpsmh/data/htdocs/images/icons/port2301.png","./opt/hp/hpsmh/data/htdocs/images/icons/security.png","./opt/hp/hpsmh/data/htdocs/images/icons/smh.png","./opt/hp/hpsmh/data/htdocs/images/icons/smh_log.png","./opt/hp/hpsmh/data/htdocs/images/icons/tcert.png","./opt/hp/hpsmh/data/htdocs/images/icons/timeouts.png","./opt/hp/hpsmh/data/htdocs/images/icons/ui_con_fig.png","./opt/hp/hpsmh/data/htdocs/images/icons/user_prefs.png","./opt/hp/hpsmh/data/htdocs/images/iconview.gif","./opt/hp/hpsmh/data/htdocs/images/legend.gif","./opt/hp/hpsmh/data/htdocs/images/legends.gif","./opt/hp/hpsmh/data/htdocs/images/listview.gif","./opt/hp/hpsmh/data/htdocs/images/logon_title.gif","./opt/hp/hpsmh/data/htdocs/images/navbar_local_trigger_bg.gif","./opt/hp/hpsmh/data/htdocs/images/navbar_local_trigger_over_bg.gif","./opt/hp/hpsmh/data/htdocs/images/navbar_notch_left.gif","./opt/hp/hpsmh/data/htdocs/images/navbar_notch_right.gif","./opt/hp/hpsmh/data/htdocs/images/photo.jpg","./opt/hp/hpsmh/data/htdocs/images/placeholder_button_img_ff.gif","./opt/hp/hpsmh/data/htdocs/images/placeholder_button_img_play.gif","./opt/hp/hpsmh/data/htdocs/images/placeholder_button_img_rewind.gif","./opt/hp/hpsmh/data/htdocs/images/placeholder_identifier_icon.gif","./opt/hp/hpsmh/data/htdocs/images/placeholder_masthead_photo_800.jpg","./opt/hp/hpsmh/data/htdocs/images/placeholder_masthead_photo_large.jpg","./opt/hp/hpsmh/data/htdocs/images/placeholder_masthead_photo_small.jpg","./opt/hp/hpsmh/data/htdocs/images/progress_bar_large.gif","./opt/hp/hpsmh/data/htdocs/images/progress_bar_medium.gif","./opt/hp/hpsmh/data/htdocs/images/progress_bar_small.gif","./opt/hp/hpsmh/data/htdocs/images/refresh.gif","./opt/hp/hpsmh/data/htdocs/images/sorted_column_asc_bg.gif","./opt/hp/hpsmh/data/htdocs/images/sorted_column_desc_bg.gif","./opt/hp/hpsmh/data/htdocs/images/status","./opt/hp/hpsmh/data/htdocs/images/status/critical_11.gif","./opt/hp/hpsmh/data/htdocs/images/status/critical_15.gif","./opt/hp/hpsmh/data/htdocs/images/status/critical_20.gif","./opt/hp/hpsmh/data/htdocs/images/status/critical_32.gif","./opt/hp/hpsmh/data/htdocs/images/status/critical_7.gif","./opt/hp/hpsmh/data/htdocs/images/status/disabled_11.gif","./opt/hp/hpsmh/data/htdocs/images/status/disabled_15.gif","./opt/hp/hpsmh/data/htdocs/images/status/disabled_20.gif","./opt/hp/hpsmh/data/htdocs/images/status/disabled_32.gif","./opt/hp/hpsmh/data/htdocs/images/status/disabled_7.gif","./opt/hp/hpsmh/data/htdocs/images/status/document_15.gif","./opt/hp/hpsmh/data/htdocs/images/status/document_32.gif","./opt/hp/hpsmh/data/htdocs/images/status/icon_status_critical.gif","./opt/hp/hpsmh/data/htdocs/images/status/icon_status_disabled.gif","./opt/hp/hpsmh/data/htdocs/images/status/icon_status_informational.gif","./opt/hp/hpsmh/data/htdocs/images/status/icon_status_major.gif","./opt/hp/hpsmh/data/htdocs/images/status/icon_status_minor.gif","./opt/hp/hpsmh/data/htdocs/images/status/icon_status_normal.gif","./opt/hp/hpsmh/data/htdocs/images/status/icon_status_unknown.gif","./opt/hp/hpsmh/data/htdocs/images/status/icon_status_warning.gif","./opt/hp/hpsmh/data/htdocs/images/status/info_11.gif","./opt/hp/hpsmh/data/htdocs/images/status/info_15.gif","./opt/hp/hpsmh/data/htdocs/images/status/info_20.gif","./opt/hp/hpsmh/data/htdocs/images/status/info_32.gif","./opt/hp/hpsmh/data/htdocs/images/status/info_7.gif","./opt/hp/hpsmh/data/htdocs/images/status/major_11.gif","./opt/hp/hpsmh/data/htdocs/images/status/major_15.gif","./opt/hp/hpsmh/data/htdocs/images/status/major_20.gif","./opt/hp/hpsmh/data/htdocs/images/status/major_32.gif","./opt/hp/hpsmh/data/htdocs/images/status/major_7.gif","./opt/hp/hpsmh/data/htdocs/images/status/minor_11.gif","./opt/hp/hpsmh/data/htdocs/images/status/minor_15.gif","./opt/hp/hpsmh/data/htdocs/images/status/minor_20.gif","./opt/hp/hpsmh/data/htdocs/images/status/minor_32.gif","./opt/hp/hpsmh/data/htdocs/images/status/minor_7.gif","./opt/hp/hpsmh/data/htdocs/images/status/normal_11.gif","./opt/hp/hpsmh/data/htdocs/images/status/normal_15.gif","./opt/hp/hpsmh/data/htdocs/images/status/normal_20.gif","./opt/hp/hpsmh/data/htdocs/images/status/normal_32.gif","./opt/hp/hpsmh/data/htdocs/images/status/normal_7.gif","./opt/hp/hpsmh/data/htdocs/images/status/status_none.gif","./opt/hp/hpsmh/data/htdocs/images/status/transparent_11.gif","./opt/hp/hpsmh/data/htdocs/images/status/transparent_15.gif","./opt/hp/hpsmh/data/htdocs/images/status/transparent_20.gif","./opt/hp/hpsmh/data/htdocs/images/status/transparent_32.gif","./opt/hp/hpsmh/data/htdocs/images/status/transparent_7.gif","./opt/hp/hpsmh/data/htdocs/images/status/unknown_11.gif","./opt/hp/hpsmh/data/htdocs/images/status/unknown_15.gif","./opt/hp/hpsmh/data/htdocs/images/status/unknown_20.gif","./opt/hp/hpsmh/data/htdocs/images/status/unknown_32.gif","./opt/hp/hpsmh/data/htdocs/images/status/unknown_7.gif","./opt/hp/hpsmh/data/htdocs/images/status/warning_11.gif","./opt/hp/hpsmh/data/htdocs/images/status/warning_15.gif","./opt/hp/hpsmh/data/htdocs/images/status/warning_20.gif","./opt/hp/hpsmh/data/htdocs/images/status/warning_32.gif","./opt/hp/hpsmh/data/htdocs/images/status/warning_7.gif","./opt/hp/hpsmh/data/htdocs/images/tab_set_bg.gif","./opt/hp/hpsmh/data/htdocs/images/tab_set_secondary_bg.gif","./opt/hp/hpsmh/data/htdocs/images/themes","./opt/hp/hpsmh/data/htdocs/images/themes/blue","./opt/hp/hpsmh/data/htdocs/images/themes/blue/button_tree_contract.gif","./opt/hp/hpsmh/data/htdocs/images/themes/blue/button_tree_expand.gif","./opt/hp/hpsmh/data/htdocs/images/themes/blue/hp_logo_invert.gif","./opt/hp/hpsmh/data/htdocs/images/themes/blue/logo_hp_largemasthead.gif","./opt/hp/hpsmh/data/htdocs/images/themes/blue/logo_hp_smallmasthead.gif","./opt/hp/hpsmh/data/htdocs/images/themes/blue/navbar_checkbox.gif","./opt/hp/hpsmh/data/htdocs/images/themes/blue/navbar_global_trigger_bg.gif","./opt/hp/hpsmh/data/htdocs/images/themes/blue/navbar_global_trigger_over_bg.gif","./opt/hp/hpsmh/data/htdocs/images/themes/blue/navbar_parent_bg.gif","./opt/hp/hpsmh/data/htdocs/images/themes/blue/navbar_parent_bg_over.gif","./opt/hp/hpsmh/data/htdocs/images/themes/blue/tab_right.gif","./opt/hp/hpsmh/data/htdocs/images/themes/blue/tab_secondary_right.gif","./opt/hp/hpsmh/data/htdocs/images/themes/green","./opt/hp/hpsmh/data/htdocs/images/themes/green/button_tree_contract.gif","./opt/hp/hpsmh/data/htdocs/images/themes/green/button_tree_expand.gif","./opt/hp/hpsmh/data/htdocs/images/themes/green/hp_logo_invert.gif","./opt/hp/hpsmh/data/htdocs/images/themes/green/logo_hp_largemasthead.gif","./opt/hp/hpsmh/data/htdocs/images/themes/green/logo_hp_smallmasthead.gif","./opt/hp/hpsmh/data/htdocs/images/themes/green/navbar_checkbox.gif","./opt/hp/hpsmh/data/htdocs/images/themes/green/navbar_global_trigger_bg.gif","./opt/hp/hpsmh/data/htdocs/images/themes/green/navbar_global_trigger_over_bg.gif","./opt/hp/hpsmh/data/htdocs/images/themes/green/navbar_parent_bg.gif","./opt/hp/hpsmh/data/htdocs/images/themes/green/navbar_parent_bg_over.gif","./opt/hp/hpsmh/data/htdocs/images/themes/green/tab_right.gif","./opt/hp/hpsmh/data/htdocs/images/themes/green/tab_secondary_right.gif","./opt/hp/hpsmh/data/htdocs/images/themes/magenta","./opt/hp/hpsmh/data/htdocs/images/themes/magenta/button_tree_contract.gif","./opt/hp/hpsmh/data/htdocs/images/themes/magenta/button_tree_expand.gif","./opt/hp/hpsmh/data/htdocs/images/themes/magenta/hp_logo_invert.gif","./opt/hp/hpsmh/data/htdocs/images/themes/magenta/logo_hp_largemasthead.gif","./opt/hp/hpsmh/data/htdocs/images/themes/magenta/logo_hp_smallmasthead.gif","./opt/hp/hpsmh/data/htdocs/images/themes/magenta/navbar_checkbox.gif","./opt/hp/hpsmh/data/htdocs/images/themes/magenta/navbar_global_trigger_bg.gif","./opt/hp/hpsmh/data/htdocs/images/themes/magenta/navbar_global_trigger_over_bg.gif","./opt/hp/hpsmh/data/htdocs/images/themes/magenta/navbar_parent_bg.gif","./opt/hp/hpsmh/data/htdocs/images/themes/magenta/navbar_parent_bg_over.gif","./opt/hp/hpsmh/data/htdocs/images/themes/magenta/tab_right.gif","./opt/hp/hpsmh/data/htdocs/images/themes/magenta/tab_secondary_right.gif","./opt/hp/hpsmh/data/htdocs/images/themes/orange","./opt/hp/hpsmh/data/htdocs/images/themes/orange/button_tree_contract.gif","./opt/hp/hpsmh/data/htdocs/images/themes/orange/button_tree_expand.gif","./opt/hp/hpsmh/data/htdocs/images/themes/orange/hp_logo_invert.gif","./opt/hp/hpsmh/data/htdocs/images/themes/orange/logo_hp_largemasthead.gif","./opt/hp/hpsmh/data/htdocs/images/themes/orange/logo_hp_smallmasthead.gif","./opt/hp/hpsmh/data/htdocs/images/themes/orange/navbar_checkbox.gif","./opt/hp/hpsmh/data/htdocs/images/themes/orange/navbar_global_trigger_bg.gif","./opt/hp/hpsmh/data/htdocs/images/themes/orange/navbar_global_trigger_over_bg.gif","./opt/hp/hpsmh/data/htdocs/images/themes/orange/navbar_parent_bg.gif","./opt/hp/hpsmh/data/htdocs/images/themes/orange/navbar_parent_bg_over.gif","./opt/hp/hpsmh/data/htdocs/images/themes/orange/tab_right.gif","./opt/hp/hpsmh/data/htdocs/images/themes/orange/tab_secondary_right.gif","./opt/hp/hpsmh/data/htdocs/in.php.en","./opt/hp/hpsmh/data/htdocs/index.php.en","./opt/hp/hpsmh/data/htdocs/ipbind.php.en","./opt/hp/hpsmh/data/htdocs/iprstrct.php.en","./opt/hp/hpsmh/data/htdocs/js","./opt/hp/hpsmh/data/htdocs/js/BoxManager.js","./opt/hp/hpsmh/data/htdocs/js/FormManager.js","./opt/hp/hpsmh/data/htdocs/js/Index.js","./opt/hp/hpsmh/data/htdocs/js/LayoutManager.js","./opt/hp/hpsmh/data/htdocs/js/PanelManager.js","./opt/hp/hpsmh/data/htdocs/js/buttonManager.js","./opt/hp/hpsmh/data/htdocs/js/dropdownMenuManager.js","./opt/hp/hpsmh/data/htdocs/js/error_table.js","./opt/hp/hpsmh/data/htdocs/js/functions.js","./opt/hp/hpsmh/data/htdocs/js/global.js","./opt/hp/hpsmh/data/htdocs/js/help_language.js.de","./opt/hp/hpsmh/data/htdocs/js/help_language.js.en","./opt/hp/hpsmh/data/htdocs/js/help_language.js.es","./opt/hp/hpsmh/data/htdocs/js/help_language.js.fr","./opt/hp/hpsmh/data/htdocs/js/help_language.js.it","./opt/hp/hpsmh/data/htdocs/js/help_language.js.ja","./opt/hp/hpsmh/data/htdocs/js/help_language.js.ko","./opt/hp/hpsmh/data/htdocs/js/help_language.js.zh-cn","./opt/hp/hpsmh/data/htdocs/js/help_language.js.zh-tw","./opt/hp/hpsmh/data/htdocs/js/navigationControlManager.js","./opt/hp/hpsmh/data/htdocs/js/tabManager.js","./opt/hp/hpsmh/data/htdocs/js/tableManager.js","./opt/hp/hpsmh/data/htdocs/js/transferBoxManager.js","./opt/hp/hpsmh/data/htdocs/js/treeManager.js","./opt/hp/hpsmh/data/htdocs/js/treeTableManager.js","./opt/hp/hpsmh/data/htdocs/js/ui.js","./opt/hp/hpsmh/data/htdocs/lang","./opt/hp/hpsmh/data/htdocs/lang.php","./opt/hp/hpsmh/data/htdocs/lang/en","./opt/hp/hpsmh/data/htdocs/lang/en/language.php","./opt/hp/hpsmh/data/htdocs/lang/en/log_messages.php","./opt/hp/hpsmh/data/htdocs/lang/ja","./opt/hp/hpsmh/data/htdocs/lang/ja/language.php","./opt/hp/hpsmh/data/htdocs/lang/ja/log_messages.php","./opt/hp/hpsmh/data/htdocs/lang/zh","./opt/hp/hpsmh/data/htdocs/lang/zh/language.php","./opt/hp/hpsmh/data/htdocs/lang/zh/log_messages.php","./opt/hp/hpsmh/data/htdocs/lang_webapp.php","./opt/hp/hpsmh/data/htdocs/legend.html","./opt/hp/hpsmh/data/htdocs/local.php.en","./opt/hp/hpsmh/data/htdocs/log_engine.php","./opt/hp/hpsmh/data/htdocs/message.php.en","./opt/hp/hpsmh/data/htdocs/message_strings.php","./opt/hp/hpsmh/data/htdocs/mod_jk2","./opt/hp/hpsmh/data/htdocs/mod_jk2/CHANGES.html","./opt/hp/hpsmh/data/htdocs/mod_jk2/CHANGES.txt","./opt/hp/hpsmh/data/htdocs/mod_jk2/INSTALL.txt","./opt/hp/hpsmh/data/htdocs/mod_jk2/LICENSE","./opt/hp/hpsmh/data/htdocs/mod_jk2/NOTICE","./opt/hp/hpsmh/data/htdocs/mod_jk2/README.txt","./opt/hp/hpsmh/data/htdocs/mod_jk2/STATUS.txt","./opt/hp/hpsmh/data/htdocs/mod_jk2/common","./opt/hp/hpsmh/data/htdocs/mod_jk2/common/AJPv13-extensions-proposal.html","./opt/hp/hpsmh/data/htdocs/mod_jk2/common/AJPv13.html","./opt/hp/hpsmh/data/htdocs/mod_jk2/common/doccontrib.html","./opt/hp/hpsmh/data/htdocs/mod_jk2/common/tools.html","./opt/hp/hpsmh/data/htdocs/mod_jk2/faq.html","./opt/hp/hpsmh/data/htdocs/mod_jk2/images","./opt/hp/hpsmh/data/htdocs/mod_jk2/images/corner.gif","./opt/hp/hpsmh/data/htdocs/mod_jk2/images/jakarta.gif","./opt/hp/hpsmh/data/htdocs/mod_jk2/images/jk2.gif","./opt/hp/hpsmh/data/htdocs/mod_jk2/images/jk2.png","./opt/hp/hpsmh/data/htdocs/mod_jk2/images/mod_jk.jpg","./opt/hp/hpsmh/data/htdocs/mod_jk2/images/pixel.gif","./opt/hp/hpsmh/data/htdocs/mod_jk2/images/tomcat.ico","./opt/hp/hpsmh/data/htdocs/mod_jk2/index.html","./opt/hp/hpsmh/data/htdocs/mod_jk2/jk2","./opt/hp/hpsmh/data/htdocs/mod_jk2/jk2/confighowto.html","./opt/hp/hpsmh/data/htdocs/mod_jk2/jk2/configtc.html","./opt/hp/hpsmh/data/htdocs/mod_jk2/jk2/configtccom.html","./opt/hp/hpsmh/data/htdocs/mod_jk2/jk2/configtcex.html","./opt/hp/hpsmh/data/htdocs/mod_jk2/jk2/configweb.html","./opt/hp/hpsmh/data/htdocs/mod_jk2/jk2/configwebcom.html","./opt/hp/hpsmh/data/htdocs/mod_jk2/jk2/configwebex.html","./opt/hp/hpsmh/data/htdocs/mod_jk2/jk2/davhowto.html","./opt/hp/hpsmh/data/htdocs/mod_jk2/jk2/installhowto.html","./opt/hp/hpsmh/data/htdocs/mod_jk2/jk2/vhosthowto.html","./opt/hp/hpsmh/data/htdocs/mod_jk2/style.css","./opt/hp/hpsmh/data/htdocs/navfile.htm","./opt/hp/hpsmh/data/htdocs/no_javascript.php","./opt/hp/hpsmh/data/htdocs/notfound.php","./opt/hp/hpsmh/data/htdocs/port2301_autostart.php","./opt/hp/hpsmh/data/htdocs/red2301.html.en","./opt/hp/hpsmh/data/htdocs/showcert.php.en","./opt/hp/hpsmh/data/htdocs/smh.css","./opt/hp/hpsmh/data/htdocs/smhhelp.php.en","./opt/hp/hpsmh/data/htdocs/smhsupport.php","./opt/hp/hpsmh/data/htdocs/smhutil","./opt/hp/hpsmh/data/htdocs/smhutil/snmpchp.php.en","./opt/hp/hpsmh/data/htdocs/smhutil/snmpchp.php.ja","./opt/hp/hpsmh/data/htdocs/success.htm","./opt/hp/hpsmh/data/htdocs/timeouts.php.en","./opt/hp/hpsmh/data/htdocs/treebody.js.en","./opt/hp/hpsmh/data/htdocs/treehead.htm.en","./opt/hp/hpsmh/data/htdocs/treehead.htm.ja","./opt/hp/hpsmh/data/htdocs/treetail.htm.en","./opt/hp/hpsmh/data/htdocs/trstcert.php.en","./opt/hp/hpsmh/data/htdocs/ui_config.php","./opt/hp/hpsmh/data/htdocs/user_prefs.php","./opt/hp/hpsmh/data/isdocs","./opt/hp/hpsmh/data/isdocs/red2301.html.en","./opt/hp/hpsmh/data/isdocs/red2301.html.ja","./opt/hp/hpsmh/data/webapp-data","./opt/hp/hpsmh/hpsum","./opt/hp/hpsmh/hpsum/adapter_mod","./opt/hp/hpsmh/lbin","./opt/hp/hpsmh/lbin/kill_smhstartd","./opt/hp/hpsmh/lbin/smhredirect","./opt/hp/hpsmh/lbin/smhstartd","./opt/hp/hpsmh/lbin/smhstartd_ipv4","./opt/hp/hpsmh/lbin/time_out","./opt/hp/hpsmh/lbin/timeout_restart","./opt/hp/hpsmh/lbin/timeoutmonitor","./opt/hp/hpsmh/lib","./opt/hp/hpsmh/lib/apr.exp","./opt/hp/hpsmh/lib/aprutil.exp","./opt/hp/hpsmh/lib/engines","./opt/hp/hpsmh/lib/libapr-1.la","./opt/hp/hpsmh/lib/libapr-1.so","./opt/hp/hpsmh/lib/libapr-1.so.0","./opt/hp/hpsmh/lib/libapr-1.so.0.5.2","./opt/hp/hpsmh/lib/libaprutil-1.la","./opt/hp/hpsmh/lib/libaprutil-1.so","./opt/hp/hpsmh/lib/libaprutil-1.so.0","./opt/hp/hpsmh/lib/libaprutil-1.so.0.5.4","./opt/hp/hpsmh/lib/libcrypto.so","./opt/hp/hpsmh/lib/libcrypto.so.1.0.0","./opt/hp/hpsmh/lib/libcurl.la","./opt/hp/hpsmh/lib/libcurl.so","./opt/hp/hpsmh/lib/libcurl.so.4","./opt/hp/hpsmh/lib/libcurl.so.4.4.0","./opt/hp/hpsmh/lib/libpcre.la","./opt/hp/hpsmh/lib/libpcre.so","./opt/hp/hpsmh/lib/libpcre.so.1","./opt/hp/hpsmh/lib/libpcre.so.1.2.9","./opt/hp/hpsmh/lib/libsmhlogwriter.so","./opt/hp/hpsmh/lib/libssl.so","./opt/hp/hpsmh/lib/libssl.so.1.0.0","./opt/hp/hpsmh/lib/libxml2.la","./opt/hp/hpsmh/lib/libxml2.so","./opt/hp/hpsmh/lib/libxml2.so.2","./opt/hp/hpsmh/lib/libxml2.so.2.9.4","./opt/hp/hpsmh/lib/libz.so","./opt/hp/hpsmh/lib/libz.so.1","./opt/hp/hpsmh/lib/libz.so.1.2.11","./opt/hp/hpsmh/lib32","./opt/hp/hpsmh/lib32/libcrypto.so.1.0.0","./opt/hp/hpsmh/lib32/libssl.so.1.0.0","./opt/hp/hpsmh/logs","./opt/hp/hpsmh/modules","./opt/hp/hpsmh/modules/httpd.exp","./opt/hp/hpsmh/modules/libphp5.so","./opt/hp/hpsmh/modules/mod_access_compat.so","./opt/hp/hpsmh/modules/mod_actions.so","./opt/hp/hpsmh/modules/mod_alias.so","./opt/hp/hpsmh/modules/mod_authz_core.so","./opt/hp/hpsmh/modules/mod_cgi.so","./opt/hp/hpsmh/modules/mod_dir.so","./opt/hp/hpsmh/modules/mod_env.so","./opt/hp/hpsmh/modules/mod_headers.so","./opt/hp/hpsmh/modules/mod_imagemap.so","./opt/hp/hpsmh/modules/mod_log_config.so","./opt/hp/hpsmh/modules/mod_mime.so","./opt/hp/hpsmh/modules/mod_negotiation.so","./opt/hp/hpsmh/modules/mod_proxy.so","./opt/hp/hpsmh/modules/mod_proxy_ajp.so","./opt/hp/hpsmh/modules/mod_proxy_balancer.so","./opt/hp/hpsmh/modules/mod_proxy_connect.so","./opt/hp/hpsmh/modules/mod_proxy_ftp.so","./opt/hp/hpsmh/modules/mod_proxy_http.so","./opt/hp/hpsmh/modules/mod_reqtimeout.so","./opt/hp/hpsmh/modules/mod_rewrite.so","./opt/hp/hpsmh/modules/mod_setenvif.so","./opt/hp/hpsmh/modules/mod_smh_help.so","./opt/hp/hpsmh/modules/mod_socache_shmcb.so","./opt/hp/hpsmh/modules/mod_unixd.so","./opt/hp/hpsmh/sbin","./opt/hp/hpsmh/sbin/cgi_pam","./opt/hp/hpsmh/sbin/hpsmhd","./opt/hp/hpsmh/sbin/php","./opt/hp/hpsmh/sbin/smhMonitor","./opt/hp/hpsmh/sbin/smhconfig","./opt/hp/hpsmh/sbin/smhrun","./opt/hp/hpsmh/sbin/smhstart","./opt/hp/hpsmh/session","./opt/hp/hpsmh/session/php","./opt/hp/hpsmh/support","./opt/hp/hpsmh/support/cs-final.sh","./opt/hp/hpsmh/support/fixperms","./opt/hp/hpsmh/support/hpsmhd.redhat","./opt/hp/hpsmh/support/hpsmhd.service","./opt/hp/hpsmh/support/hpsmhd.united1","./opt/hp/hpsmh/support/sysmgthp.redhat","./opt/hp/hpsmh/support/sysmgthp.rh32","./opt/hp/hpsmh/support/sysmgthp.united1","./opt/hp/hpsmh/tmp","./opt/hp/hpsmh/webapp","./usr/local/hp/hpSMHSetup","./usr/local/hp/hpSMHSetup.pl","./usr/local/hp/hpSMHSetup/L10N","./usr/local/hp/hpSMHSetup/L10N.pm","./usr/local/hp/hpSMHSetup/L10N/en.pm","./usr/local/hp/hpbacl.sh","./usr/local/hp/hpfdtn.sh","./usr/local/hp/hpwebsetup","./usr/local/hp/shmchk"],"md5sum":"5ecbadbd2f599a9355ed72c707dacbfa","name":"hpsmh-7.6.6-2.x86_64.rpm","release":"2020-07-13T13:44:13","revision":"0","sha1sum":"84f11c568725350cd7a2becfbdb0c6201a92723d","size":"14MB","target_guids":[],"type_of_change":"1","version":"7.6.6-2"}],"id":{"product":"C8718","version":"2297bd211a9e45a4b4f6c9a8aba7aa43"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the rpm package to a directory on your hard drive and change the directory accordingly. Use the following commands for specific tasks:\n<ol>\n <li>\n  <strong>Installation</strong>: rpm -ivh hpsmh-&lt; version &gt;.x86_64.rpm</li>\n <li>\n  <strong>Upgrade</strong> (from lower version to higher version): rpm -Uvh hpsmh-&lt;version&gt;.x86_64.rpm&gt;</li>\n <li>\n  <strong>Reinstallation</strong> (of same version): rpm -Uvh hpsmh-&lt;version&gt;.x86_64.rpm</li>\n <li>\n  <strong>Downgrade</strong> (from higher version to lower version): User needs to uninstall the higher version (rpm &ndash;e hpsmh-&lt;version&gt;) and then install the lower version (rpm -ivh hpsmh-&lt;version&gt;.x86_64.rpm).</li>\n</ol>\n"},{"lang":"ja","x_late":"ハードディスクドライブのディレクトリにrpmパッケージをダウンロードし、そのディレクトリに移動します。 固有のタスクのために次のコマンドを使用します。\n<ol>\n <li>\n  <strong>インストール</strong>： rpm -ivh hpsmh-< version >.x86_64.rpm</li>\n <li>\n  <strong>アップグレード</strong> (下位バージョンから上位バージョンへ)： rpm -Uvh hpsmh-<version>.x86_64.rpm></li>\n <li>\n  <strong>再インストール</strong> (同じバージョン)： rpm -Uvh hpsmh-<version>.x86_64.rpm</li>\n <li>\n  <strong>ダウングレード</strong> (上位バージョンから下位バージョンへ)： ユーザーは上位バージョンをアンインストールする(rpm –e hpsmh-<version>)必要があり、その後下位バージョンをインストールしてください(rpm -ivh hpsmh-<version>.x86_64.rpm)。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Linux (AMD64/EM64T) 的 HPE System Management Homepage"},{"lang":"en","x_late":"HPE System Management Homepage for Linux (AMD64/EM64T)"},{"lang":"ko","x_late":"Linux(AMD64/EM64T)용 HPE System Management Homepage"},{"lang":"cn","x_late":"用于 Linux (AMD64/EM64T) 的 HPE System Management Homepage"},{"lang":"ja","x_late":"HPE System Management Homepage for Linux（AMD64/EM64T）"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"5","minor":"0","name":"Red Hat Enterprise Linux 5 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"5","minor":"0","name":"Oracle Linux 5 (AMD64/EMT64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Workstation (x86-64)","platform":"red_hat_enterprise_linux_client_x86_64","sr":"OEM"},{"major":"5","minor":"0","name":"Red Hat Enterprise Linux 5 Desktop (x86-64)","platform":"red_hat_enterprise_linux_client_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-02-10T06:29:35","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>New OS Support</p>\n\n<ul>\n\t<li>RHEL 8</li>\n\t<li>SLES15 SP1</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Updated the following components:</p>\n\n<ul>\n\t<li>&nbsp;&nbsp;&nbsp; Apache to version 2.4.41</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P74","value":"HP ProLiant SL140s Gen8 Server (private)"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 v2 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P78","value":"HP ProLiant ML310e Gen8 v2 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"P83","value":"HP ProLiant SL210t Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"},{"key":"","value":"HPE System Management Homepage Software"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"}],"sw_keys":[{"name":"hpsmh","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following storage controllers: HPE HBA(Host Bus Adapters) H221"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のストレージコントローラーのファームウェアを提供します。 HPE HBA（ホストバスアダプター）H221"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for Linux - HPE HBA(Host Bus Adapter) H221&nbsp;</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 15.10.10.00 (C)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 15.10.10.00 (D)<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 15.10.10.00<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;&nbsp;&nbsp; Improved Integration with Smart Update Manager.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Known Issues:</strong>&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"3986270","datemodified":"2018-11-07T04:30:39","file_list":["./usr/lib/i386-linux-gnu/firmware-43d7eff89e-15.10.10.00-3.1","./usr/lib/i386-linux-gnu/firmware-43d7eff89e-15.10.10.00-3.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-43d7eff89e-15.10.10.00-3.1/.setup","./usr/lib/i386-linux-gnu/firmware-43d7eff89e-15.10.10.00-3.1/CP038050.xml","./usr/lib/i386-linux-gnu/firmware-43d7eff89e-15.10.10.00-3.1/H210i_it.fw","./usr/lib/i386-linux-gnu/firmware-43d7eff89e-15.10.10.00-3.1/H220_it.fw","./usr/lib/i386-linux-gnu/firmware-43d7eff89e-15.10.10.00-3.1/H220i_it.fw","./usr/lib/i386-linux-gnu/firmware-43d7eff89e-15.10.10.00-3.1/H221_it.fw","./usr/lib/i386-linux-gnu/firmware-43d7eff89e-15.10.10.00-3.1/H222_it.fw","./usr/lib/i386-linux-gnu/firmware-43d7eff89e-15.10.10.00-3.1/firmware.cfg","./usr/lib/i386-linux-gnu/firmware-43d7eff89e-15.10.10.00-3.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-43d7eff89e-15.10.10.00-3.1/lsiflash","./usr/lib/i386-linux-gnu/firmware-43d7eff89e-15.10.10.00-3.1/mptsas2.rom","./usr/lib/i386-linux-gnu/firmware-43d7eff89e-15.10.10.00-3.1/sas2flash","./usr/lib/i386-linux-gnu/firmware-43d7eff89e-15.10.10.00-3.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP038050.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP038050.scexe"],"md5sum":"03fe69ec5c28de227185004658e19356","name":"firmware-43d7eff89e-15.10.10.00-3.1.i386.rpm","release":"2018-11-07T10:29:03","revision":"0","sha1sum":"d56cf0c3d39d252d2e14bff78244fc0f6b306bda","size":"3MB","target_guids":[],"type_of_change":"0","version":"15.10.10.00"}],"id":{"product":"b708791c2556438caa9e3c26486663c3","version":"a6849ac36d1c4fd49ad6989aa8203192"},"installation":{"command":"CP038050.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><em><strong>Updating firmware with rpm installed:</strong></em></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp; rpm -ivh &lt;rpm_filename&gt;.&nbsp; This extracts the contents of the rpm to the &#39;/usr/lib/i386-linux-gnu&#39; location</li>\n\t<li>The CP038050.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-43d7eff89e-*&#39; folder is based on the version of the rpm installed in the first step above</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./ CP038050.scexe in the &#39;/usr/lib/i386-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li>./setup in the &#39;/usr/lib/i386-linux-gnu/firmware-smartarray-43d7eff89e-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: rpm -e &lt;rpm_package_name&gt;, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><em><strong>Updating firmware without installing the rpm:</strong></em></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the &#39;usr/lib/i386-linux-gnu/hp-firmware-smartarray-43d7eff89e-*&#39; location and run ./hpsetup to update the firmware. The actual name of the &#39;hp-firmware-smartarray-43d7eff89e-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><em><strong>Additional Information:</strong></em></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp; It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HP Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\"><u>Service Pack for ProLiant&nbsp;</u></a>on a USB key using the&nbsp;<a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li>\n\t<li>Run launch_sum.sh script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE Host Bus Adapters H221"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPEホストバスアダプターH221"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_devices":[{"dev":"0087","subdev":"0042","subven":"1590","target_guid":"","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (x86)","platform":"suse_linux_enterprise_server_x86","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86)","platform":"red_hat_enterprise_linux_x86","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-12-02T08:38:55","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Fixes an issue where the appropriate FW version for the Host Bus Adapter (HBA) Stockade (H2xx) driver will not install when using the Service Pack ProLiant (SPP)</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Improved Integration with Smart Update Manager.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"}],"sw_keys":[{"name":"00441590","sw_key_expectedpath":"firmware:sd:hba"},{"name":"00461590","sw_key_expectedpath":"firmware:sd:hba"},{"name":"00411590","sw_key_expectedpath":"firmware:sd:hba"},{"name":"00431590","sw_key_expectedpath":"firmware:sd:hba"},{"name":"00421590","sw_key_expectedpath":"firmware:sd:hba"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK0400JEABD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM2RD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3430-304a45414244","Version":"HPD4"},{"DeviceName":"VK0800JEABE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM2RD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3830-304a45414245","Version":"HPD4"},{"DeviceName":"VO1600JEABF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM2RD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314f-3630-304a45414246","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK0400JEABD, VK0800JEABE, and VO1600JEABF"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK0400JEABD、VK0800JEABE、およびVO1600JEABF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online HDD/SSD Flash Component for VMware ESXi - VK0400JEABD, VK0800JEABE, and VO1600JEABF Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD3</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>If Power On Hours exceeds 70,000hrs, PM2R will report Hardware error (04/4C/A8) after the next Power Cycle and will not accept read/write commands. This fix will update storage location reporting when the maximum number of registrations in the Work Load Log read process reaches 70,000; the last registered 70,000th storage location will be modified to be read as the next (70,001st) storage location.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111296en_us</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"15933311","datemodified":"2021-08-31T11:11:39","file_list":["/CP049410_BUILD_1.data","/CP049410.vmexe","/CP049410.vmexe64","/CP049410.vmfile","/CP049410_VMw.zip","/CP049410.xml","/payload.json","/CP049410_VMw.zip/index.xml","/CP049410_VMw.zip/vendor-index.xml","/CP049410_VMw.zip/metadata.zip","/CP049410_VMw.zip/vib20/CP049410/HPE_bootbank_CP049410_HPD4.1-7.0.0.15843807.vib","/CP049410_VMw.zip/metadata.zip/vendor-index.xml","/CP049410_VMw.zip/metadata.zip/vmware.xml","/CP049410_VMw.zip/metadata.zip/vibs/CP049410--57547943028718795.xml","/CP049410_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049410_HPD4.1-7.0.0.15843807.xml"],"md5sum":"c09bbb34d1c6db1508a9c42bd9c704ba","name":"CP049410.zip","release":"2021-08-31T11:07:09","revision":"0","sha1sum":"07a5c9c337b74d02ee6c540dbeb07f9c4ffb6654","size":"15MB","target_guids":["002340a5-5600-304b-3430-304a45414244","002340a5-5600-304b-3830-304a45414245","002340a5-5600-314f-3630-304a45414246"],"type_of_change":"2","version":"HPD4","vib_list":[{"name":"CP049410","version":"HPD4.1-7.0.0.15843807"}]}],"id":{"product":"07a177efdb914ccfaea8cc2d7cc450db","version":"88395a535d3d4b02879c40ed89b30f46"},"installation":{"command":"CP031687.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK0400JEABD, VK0800JEABE, and VO1600JEABF Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VK0400JEABD、VK0800JEABE、およびVO1600JEABFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VO1600JEABF","target_guid":"002340a5-5600-314f-3630-304a45414246","type":"sas"},{"id":"VK0400JEABD","target_guid":"002340a5-5600-304b-3430-304a45414244","type":"sas"},{"id":"VK0800JEABE","target_guid":"002340a5-5600-304b-3830-304a45414245","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-30T10:15:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>If Power On Hours exceeds 70,000hrs, PM2R will report Hardware error (04/4C/A8) after the next Power Cycle and will not accept read/write commands. This fix will update storage location reporting when the maximum number of registrations in the Work Load Log read process reaches 70,000; the last registered 70,000th storage location will be modified to be read as the next (70,001st) storage location.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111296en_us</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>If Power On Hours exceeds 70,000hrs, PM2R will report Hardware error (04/4C/A8) after the next Power Cycle and will not accept read/write commands. This fix will update storage location reporting when the maximum number of registrations in the Work Load Log read process reaches 70,000; the last registered 70,000th storage location will be modified to be read as the next (70,001st) storage location.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111296en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK0400JEABD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO1600JEABF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VK0800JEABE","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GEBTP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHC6FG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745425450","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB6000GEBTP Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MB6000GEBTPドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB6000GEBTP Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5091034","datemodified":"2021-07-23T07:29:57","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-3243fce9a0-HPG4-9.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-3243fce9a0-HPG4-9.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-3243fce9a0-HPG4-9.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3243fce9a0-HPG4-9.1/CP048166.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-3243fce9a0-HPG4-9.1/HAHC6FG4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-3243fce9a0-HPG4-9.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3243fce9a0-HPG4-9.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-3243fce9a0-HPG4-9.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-3243fce9a0-HPG4-9.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048166.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048166.scexe"],"md5sum":"0a0a610074cf03e288b061732e3ffe9b","name":"firmware-hdd-3243fce9a0-HPG4-9.1.x86_64.rpm","release":"2021-07-23T07:16:15","revision":"0","sha1sum":"4ab79bd9a7f90f838401643faa8e131437fd5613","size":"4MB","target_guids":["002340a5-4d00-3642-3030-304745425450"],"type_of_change":"1","version":"HPG4"}],"id":{"product":"aa6bec5edbc1481bba28cd93023707d3","version":"d54a59d54d24464dac315fcacdc6bc1a"},"installation":{"command":"CP040321.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB6000GEBTP Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB6000GEBTPドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"MB6000GEBTP","target_guid":"002340a5-4d00-3642-3030-304745425450","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T19:35:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000GEBTP","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6151649","datemodified":"2021-05-18T01:23:57","file_list":["./usr/lib/i386-linux-gnu/firmware-system-u14-2.90_2021_04_29-1.1","./usr/lib/i386-linux-gnu/firmware-system-u14-2.90_2021_04_29-1.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-system-u14-2.90_2021_04_29-1.1/.setup","./usr/lib/i386-linux-gnu/firmware-system-u14-2.90_2021_04_29-1.1/CP047892.xml","./usr/lib/i386-linux-gnu/firmware-system-u14-2.90_2021_04_29-1.1/U14_2.90_04_29_2021.signed.flash","./usr/lib/i386-linux-gnu/firmware-system-u14-2.90_2021_04_29-1.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-system-u14-2.90_2021_04_29-1.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP047892.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP047892.scexe"],"md5sum":"b11d6dc8fd2937ef25d247514d0cc0fb","name":"firmware-system-u14-2.90_2021_04_29-1.1.i386.rpm","release":"2021-05-18T01:13:05","revision":"0","sha1sum":"c6f80309940580458de324879848d63a186aba54","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021"}],"id":{"product":"c22851f0ee734a8da996d363b5084433","version":"78fb4280a61e4d3b882ca635358b7742"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HPE ProLiant Agentless Management Service (<strong>AMS</strong>) and HPE SNMP Agents (<strong>SNMP Agents</strong>) are both running.&nbsp; HPE does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager 8.0.0 or later, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、iLOとの通信ができない場合に失敗します。  これは、HPE ProLiant Agentless Management Service (<strong>AMS</strong>)およびHPE SNMPエージェント(<strong>SNMP Agents</strong>)の両方が実行されているときに発生します。  HPEでは、AMSおよびSNMPエージェントを同時に実行させないことを推奨します。  「iLO device not found」エラーが発生した場合、AMSまたはSNMPエージェントを停止させて、再度フラッシュコンポーネントを実行します。<br />\n<br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上のSmart Update Manager 8.0.0以降を使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant XL170r/XL190r Gen9 (U14) Servers "},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Linux - HPE ProLiant XL170r/XL190r Gen9（U14）サーバー "}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-06T15:45:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","latest_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358.  These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390.  These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"U14","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HP Ethernet 10Gb 2-port 560FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":60,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-10F8103C18D0","Version":"1.2836.0"},{"DeviceName":"HP Ethernet 10Gb 2-port 560M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":60,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-10F8103C17D2","Version":"1.2836.0"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This component contains utilities and firmware for the online upgrade of HPE Blade Intel NIC firmware running under Microsoft Windows Server 2012 R2, Windows Server 2016 and Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントには、Windows Server 2012 R2、Windows Server 2016、およびWindows Server 2019で動作するHPE Blade Intel NICファームウェアをオンラインでアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions for the below listed supported nework adapters:</p>\n\n<table border=\"1\">\n\t<thead>\n\t\t<tr>\n\t\t\t<th>NIC</th>\n\t\t\t<th>EEPROM/NVM Version</th>\n\t\t\t<th>OROM Version</th>\n\t\t</tr>\n\t</thead>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 560FLB Adapter</td>\n\t\t\t<td>800008F0</td>\n\t\t\t<td>1.2836.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 560M Adapter</td>\n\t\t\t<td>8000083D</td>\n\t\t\t<td>1.2836.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>The combo image v1.2836.0 includes: Boot Agent: 1GbE - v1.5.88, 10GbE - v2.4.44, 40GbE - v1.1.18&nbsp;&amp; UEFI Drivers: 1GbE - v9.4.06, 10GbE - v7.8.13, 40GbE - v4.4.12</p>\n"}],"files":[{"bytes":"5870424","datemodified":"2021-08-12T02:42:24","file_list":["BNICOFUT.pdf","cp047539.xml","cpqsetup.exe","FW/","FW/BootIMG.FLB","FW/hpesinglenvmconfig.txt","FW/HPE_560FLB_G33590-000_2.45_800008F0.txt","FW/HPE_560M_G43498-00X_2.18_8000083D.txt","FW/HPE_XG_Adapter_VPD_MAP.txt","FW/hpnvmupdate.cfg","HPNVMUpdate.exe","install.bat","iqvsw64e.cat","iqvsw64e.inf","iqvsw64e.sys","ja/","ja/BNICOFUT_JA.pdf","nvmupdate.bat","nvmupdatewin64e.dll","ofvpdfixW64e.exe","OnlineFWUpgrade.dll","payload.json","rfendfixW64e.exe","zh-CN/","zh-CN/BNICOFUT_ZHCN.pdf"],"md5sum":"fcf3190fa85044e8c9402cb91414646d","name":"cp047539.exe","release":"2021-08-12T02:33:29","revision":"0","sha1sum":"2f93fa5f08354bd7bcf79569c59942511553f50a","size":"5MB","target_guids":["a6b1a447-382a-5a4f-8086-10F8103C18D0","a6b1a447-382a-5a4f-8086-10F8103C17D2"],"type_of_change":"0","version":"1.0.5.2"}],"id":{"product":"5676950ebe02418986b260051b7d33cb","version":"d6bd63b522764028981e90034cb2462a"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca94d0369","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel E1R Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5963c8f7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel E1R Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec090ca3ac","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel E1R Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec08dc7810","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecaf3c08f1","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3804451b","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecee44051c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2bead763","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec8a51872f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca9730c7d","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfc261833","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3bb214b3","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec45933bde","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixs Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2cbf818e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixs Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec507d6c9c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40eb Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec77fc8d87","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40eb Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfbeb7312","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel E1R Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecc6f71532","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec24ae2520","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40eb Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec619e0b4b","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecee44d472","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixs Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixt Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5c8e5025","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.1.197.0","description":"HPE Intel ixt Driver for Windows Server 2019 must be installed prior to this component"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation.</p>\n\n<p>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</p>\n\n<p>&nbsp;</p>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>When updating&nbsp;firmware, refer to the Revision History and update&nbsp;to the next version as stepping up or down the ladder until the version needed is reached. For more information about downgrade limitations, refer to the following Customer advisory:&nbsp;https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00069764en_us.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</p>\n\n<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p>\n\n<p>［インストール］ボタンをクリックして、インストールを開始します。</p>\n\n<p>アップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</p>\n\n<p> </p>\n\n<p><strong><em>追加情報：</em></strong></p>\n\n<ul>\n\t<li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきながら、次のバージョンにアップデートします。ダウングレードに関する制限について詳しくは、カスタマーアドバイザリhttps://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00069764en_usを参照してください。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Intel Online Firmware Upgrade Utility for Windows Server x64 Editions"},{"lang":"ja","x_late":"HPE Blade Intelオンラインファームウェアアップグレードユーティリティ for Windows Server x64 Editions"}],"prerequisites":{"required_diskspace":{"size_kb":"4100"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-03T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This firmware is updated to maintain compatibility with the updated Windows ixn drivers.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product no longer supports Windows Server 2012 R2.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"HPNVMUpdate.exe","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWSRQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757535251","Version":"HPG4"},{"DeviceName":"VK000480GWSRR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757535252","Version":"HPG4"},{"DeviceName":"VK000960GWSRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757535254","Version":"HPG4"},{"DeviceName":"VK001920GWSRU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757535255","Version":"HPG4"},{"DeviceName":"VK003840GWSRV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304757535256","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK000240GWSRQ, VK000480GWSRR, VK000960GWSRT, VK001920GWSRU and VK003840GWSRV "},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VK000240GWSRQ、VK000480GWSRR、VK000960GWSRT、VK001920GWSRU、およびVK003840GWSRV "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for&nbsp;Windows (x64)&nbsp;- VK000240GWSRQ, VK000480GWSRR, VK000960GWSRT, VK001920GWSRU and&nbsp;VK003840GWSRV Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4485632","datemodified":"2021-07-25T21:08:38","file_list":["cp048657.xml","cpqsetup.exe","GPM883G4.rel","payload.json","setup.dll"],"md5sum":"e1ce8ae22948e4bd9f6088ca04316c68","name":"cp048657.exe","release":"2021-07-25T21:01:04","revision":"0","sha1sum":"66e7d03f62bd3ab83e128c1a695e15dc2c662c05","size":"4MB","target_guids":["562340a5-304b-3030-3234-304757535251","562340a5-304b-3030-3438-304757535252","562340a5-304b-3030-3936-304757535254","562340a5-304b-3130-3932-304757535255","562340a5-304b-3330-3834-304757535256"],"type_of_change":"1","version":"HPG4"}],"id":{"product":"b2ba8bbc89f8475a9e824abb19fcc091","version":"2ab45f9f078544dfb1e6d9a6d1aef563"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK000240GWSRQ, VK000480GWSRR, VK000960GWSRT, VK001920GWSRU and VK003840GWSRV  Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - VK000240GWSRQ、VK000480GWSRR、VK000960GWSRT、VK001920GWSRU、およびVK003840GWSRVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VK003840GWSRV","target_guid":"562340a5-304b-3330-3834-304757535256","type":"sata"},{"id":"VK001920GWSRU","target_guid":"562340a5-304b-3130-3932-304757535255","type":"sata"},{"id":"VK000960GWSRT","target_guid":"562340a5-304b-3030-3936-304757535254","type":"sata"},{"id":"VK000480GWSRR","target_guid":"562340a5-304b-3030-3438-304757535252","type":"sata"},{"id":"VK000240GWSRQ","target_guid":"562340a5-304b-3030-3234-304757535251","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-17T05:14:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK001920GWSRU","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GWSRV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWSRQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWSRT","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWSRR","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter and mezzanine host bus adapters. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"5700793","datemodified":"2021-08-27T03:33:49","file_list":["./etc/depmod.d/qla2xxx.conf","./etc/dracut.conf.d/qla2xxx.conf","./etc/udev/rules.d/99-qla2xxx.rules","./lib/modules/4.18.0-305.el8.x86_64","./lib/modules/4.18.0-305.el8.x86_64/extra","./lib/modules/4.18.0-305.el8.x86_64/extra/qlgc-qla2xxx","./lib/modules/4.18.0-305.el8.x86_64/extra/qlgc-qla2xxx/qla2xxx.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/qlgc-qla2xxx/tcm_qla2xxx.ko","./lib/udev/qla2xxx_udev.sh","./usr/share/smartupdate/kmod-qlgc-qla2xxx/component.xml"],"md5sum":"066fe2bf46c6966d3f941f0e81454bba","name":"kmod-qlgc-qla2xxx-10.02.01.01.a2_k1-4.rhel8u4.x86_64.rpm","release":"2021-09-23T00:00:00","revision":"1","sha1sum":"eec8ad3c5e2669b5d395a5c65a928556d95e4e88","size":"5MB","target_guids":[],"type_of_change":"1","version":"10.02.01.01.a2-k1"}],"id":{"product":"8cd3b77d53bb4db4b8613e8bf7249617","version":"fdbf6739bbd24e7eb4a8bc83dcaad489"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-qlgc-qla2xxx-10.02.01.01.a2_k1-1.rhel8u4.x86_64.rpm<br />\n<br />\n4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;&nbsp;</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Red Hat Enterprise Linux 8 Update 4 Server Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters and Mezzanine Host Bus Adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015D","subven":"1077","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015C","subven":"1077","target_guid":"","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-10-30T11:07:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Added the following:-</strong></p>\n\n<ul>\n\t<li>\n\t<p dir=\"LTR\">Initial driver for RHEL 8.4</p>\n\t</li>\n</ul>\n\n<p>Updated to driver version 10.02.01.01.a2-k1</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>Added the following:-</strong></p>\n\n<ul>\n\t<li>\n\t<p dir=\"LTR\">Initial driver for RHEL 8.4</p>\n\t</li>\n</ul>\n\n<p>Updated to driver version 10.02.01.01.a2-k1</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"kmod-qlgc-qla2xxx","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO0400KEFJB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304f-3430-304b45464a42","Version":"HPK4"},{"DeviceName":"VO1200KEFJC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314f-3230-304b45464a43","Version":"HPK4"},{"DeviceName":"VO2000KEFJD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-324f-3030-304b45464a44","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VO0400KEFJB, VO1200KEFJC and VO2000KEFJD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for VMware ESXi - VO0400KEFJB, VO1200KEFJC&nbsp;and VO2000KEFJD Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>&nbsp;None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16034982","datemodified":"2021-09-24T10:12:44","file_list":["/CP045719_BUILD_5.data","/CP045719.vmexe","/CP045719.vmexe64","/CP045719.vmfile","/CP045719_VMw.zip","/CP045719.xml","/payload.json","/CP045719_VMw.zip/index.xml","/CP045719_VMw.zip/vendor-index.xml","/CP045719_VMw.zip/metadata.zip","/CP045719_VMw.zip/vib20/CP045719/HPE_bootbank_CP045719_HPK4.5-7.0.0.15843807.vib","/CP045719_VMw.zip/metadata.zip/vendor-index.xml","/CP045719_VMw.zip/metadata.zip/vmware.xml","/CP045719_VMw.zip/metadata.zip/vibs/CP045719-6546131769518136308.xml","/CP045719_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045719_HPK4.5-7.0.0.15843807.xml"],"md5sum":"ace4741361ca00b443a4f7e710842cd0","name":"CP045719.zip","release":"2021-09-24T10:06:39","revision":"0","sha1sum":"590b053825c7fc3f5b989aac0b08e5e601d6759a","size":"15MB","target_guids":["002340a5-5600-304f-3430-304b45464a42","002340a5-5600-314f-3230-304b45464a43","002340a5-5600-324f-3030-304b45464a44"],"type_of_change":"1","version":"HPK4","vib_list":[{"name":"CP045719","version":"HPK4.5-7.0.0.15843807"}]}],"id":{"product":"151b3249eb8946acb43e16f663033dfa","version":"a131cd14ac3f467598a1dc6a0c005449"},"installation":{"command":"CP040194.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi - VO0400KEFJB, VO1200KEFJC and VO2000KEFJD Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VO0400KEFJB","target_guid":"002340a5-5600-304f-3430-304b45464a42","type":"nvme"},{"id":"VO1200KEFJC","target_guid":"002340a5-5600-314f-3230-304b45464a43","type":"nvme"},{"id":"VO2000KEFJD","target_guid":"002340a5-5600-324f-3030-304b45464a44","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:48:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO0400KEFJB","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO1200KEFJC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO2000KEFJD","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE QLogic FastLinQ 10/25/50 Gigabit Ethernet NICs running under Red Hat Enterprise Linux 7 x86_64."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7 x86_64で動作するHPE QLogic FastLinQ 10/25/50 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"13013814","datemodified":"2021-08-11T14:42:51","file_list":["./etc/depmod.d/fastlinq.conf","./etc/dracut.conf.d/fastlinq.conf","./lib/firmware/qed","./lib/firmware/qed/qed_init_values_zipped-8.50.18.0.bin","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/qlgc-fastlinq","./lib/modules/3.10.0-1127.el7.x86_64/extra/qlgc-fastlinq/qed.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/qlgc-fastlinq/qede.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/qlgc-fastlinq/qedf.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/qlgc-fastlinq/qedi.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/kmod-qlgc-fastlinq/component.xml"],"md5sum":"66e01c60749f0a8754d5ae2dee48fdda","name":"kmod-qlgc-fastlinq-8.55.14.0-2.rhel7u8.x86_64.rpm","release":"2021-08-11T14:16:16","revision":"0","sha1sum":"5d5916a14ee58c064f4c073d1922309e0da3e67f","size":"12MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd6456294"],"type_of_change":"0","version":"8.55.14.0-2"},{"bytes":"13018048","datemodified":"2021-08-11T14:50:37","file_list":["./etc/depmod.d/fastlinq.conf","./etc/dracut.conf.d/fastlinq.conf","./lib/firmware/qed","./lib/firmware/qed/qed_init_values_zipped-8.50.18.0.bin","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/qlgc-fastlinq","./lib/modules/3.10.0-1160.el7.x86_64/extra/qlgc-fastlinq/qed.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/qlgc-fastlinq/qede.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/qlgc-fastlinq/qedf.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/qlgc-fastlinq/qedi.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/kmod-qlgc-fastlinq/component.xml"],"md5sum":"f442a5d23ff1b95a9883af30f27832b9","name":"kmod-qlgc-fastlinq-8.55.14.0-2.rhel7u9.x86_64.rpm","release":"2021-08-11T14:16:16","revision":"0","sha1sum":"92c923847b92b4227353eb43f4b035024881cb9c","size":"12MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd6456294"],"type_of_change":"0","version":"8.55.14.0-2"}],"id":{"product":"882bb8e4707345cbb8f1e7ba0901abee","version":"33cd51c9b700416d8cbc43c40fd86dd6"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>Download README for any additional installation instructions.</p>\n"},{"lang":"ja","x_late":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>\n\n<p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>\n\n<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>\n\n<p> </p>\n\n<p>その他のインストール手順についてのREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE QLogic FastLinQ 10/25/50 GbE Drivers for Red Hat Enterprise Linux 7 x86_64"},{"lang":"ja","x_late":"Red Hat Enterprise Linux 7 x86_64用HPE QLogic FastLinQ 10/25/50 GbEドライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"8070","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021d","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021f","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0074","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770074","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0073","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770073","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-807015900220","type":"pci","ven":"1077"},{"dev":"8070","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8070159002bd","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0070","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770070","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0069","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770069","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0068","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770068","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0071","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770071","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0072","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770072","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021a","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021b","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0070","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770070","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0069","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770069","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0068","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770068","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0071","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770071","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0072","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770072","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0074","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770074","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0073","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770073","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product is particular for&nbsp;Red Hat Enterprise Linux 7 Update 8 patched kernel version 3.10.0-1127.10.1 or later.</p>\n","latest_fixes_x_late":"<p>This product corrects an issue where the patched kernel symbol changed on PTP (Precision Time Protocol) module.</p>\n\n<p>&nbsp;</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where the 10GbE Adapters having an DNS resolution issue on Kubernetes container-orchestration system</li>\n\t<li>This product addresses an issue where system crashes after PCIe error injection multiple times on HPE SDFlex system</li>\n\t<li>This product addresses an issue where the ethernet data rate limiting doesn&#39;t work for Virtual Functions (VFs) .</li>\n\t<li>This product addresses an issue where the system crash once there are not enough number of msix vectors as requested for Virtual Functions (VFs).</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-qlgc-fastlinq","sw_key_expectedpath":"software:rpm"},{"name":"kmod-qlgc-fastlinq","sw_key_expectedpath":"software:rpm"},{"name":"kmod-qlgc-fastlinq","sw_key_expectedpath":"software:rpm"},{"name":"kmod-qlgc-fastlinq","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GEBTP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHC6FG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745425450","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB6000GEBTP"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;&nbsp;(x64)&nbsp;- MB6000GEBTP Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3238232","datemodified":"2021-07-25T15:10:32","file_list":["cp048610.xml","cpqsetup.exe","HAHC6FG4.rel","payload.json","setup.dll"],"md5sum":"c6acf4324a4bc27a3107a1939dbcadb5","name":"cp048610.exe","release":"2021-07-25T15:03:14","revision":"0","sha1sum":"06b8fe5a0d9c934e55b52273a187feb5b3aba929","size":"3MB","target_guids":["002340a5-4d00-3642-3030-304745425450"],"type_of_change":"1","version":"HPG4"}],"id":{"product":"e2d7a4e705f34372b47092c82c533260","version":"defb32a536074500a9b7610c18c6d6d1"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"text-decoration-line: none; color: blue;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB6000GEBTP Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB6000GEBTPドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB6000GEBTP","target_guid":"002340a5-4d00-3642-3030-304745425450","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T11:18:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000GEBTP","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware for Mezzanine Converged Network adapters."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"7597480","datemodified":"2021-08-27T07:19:34","file_list":["brcmflashStandalone-windows-12.0.1336.0-1/firmware/","brcmflashStandalone-windows-12.0.1336.0-1/firmware/oc14-12.0.1336.0.ufi","brcmflashStandalone-windows-12.0.1336.0-1/win/","brcmflashStandalone-windows-12.0.1336.0-1/win/brcmflash.bat","brcmflashStandalone-windows-12.0.1336.0-1/win/brcmwinlpcfg.bat","brcmflashStandalone-windows-12.0.1336.0-1/win/x64/","brcmflashStandalone-windows-12.0.1336.0-1/win/x64/brcmflash.exe","brcmflashStandalone-windows-12.0.1336.0-1/win/x64/BrcmMILI.dll","brcmflashStandalone-windows-12.0.1336.0-1/win/x64/brcmwinlpcfg.exe","brcmflashStandalone-windows-12.0.1336.0-1/win/x64/firmware/","brcmflashStandalone-windows-12.0.1336.0-1/win/x64/libbrcmdfc.dll","brcmflashStandalone-windows-12.0.1336.0-1/win/x64/RM.INI","cp049112.xml","cpqsetup.exe","fwmatrix.txt","brcmflashStandalone-windows-12.0.1336.0-1/win/x64/fwmatrix.txt","hpe_fw_matrix.xml","installer.dll","payload.json","readme.txt","brcmflashStandalone-windows-12.0.1336.0-1/win/x64/readme.txt","reference.xml"],"md5sum":"8eb79a7263431d9e32e6015e6421445e","name":"cp049112.exe","release":"2021-08-27T07:04:48","revision":"0","sha1sum":"aeabe8da57bd0449f5780dfb4e8e2d1b844d5d2b","size":"7MB","target_guids":[],"type_of_change":"1","version":"2021.10.01"}],"id":{"product":"4f0ca76d91924b51aab6d221a15c2410","version":"cc019a754f664903a58ee25b32af0e6a"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p dir=\"LTR\">Download the Smart Component to a directory on your hard drive and change to that directory.</p>\n\n<p>The downloaded file is a self-extracting executable with a filename based on the Component Number.<br />\nFrom that drive and directory, execute the downloaded file.<br />\n<br />\nClick the &quot;Install&quot; button to proceed with the installation.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Firmware Flash for Emulex Mezzanine Converged Network Adapters for Microsoft Windows Server 2012R2(x64)"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"0724","subdev":"1935","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1935","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1934","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"1934","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-23T08:58:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 20Gb 2-port 650FLB Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 20Gb 2-port 650M Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"emulex_cna","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Apollo InfiniBand EDR 100Gb 2-port 840z Mezzanine FIO Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_2006-843400-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000EF","Version":"12.28.2006"},{"DeviceName":"HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_31_1014-872723-B21_Ax-UEFI-14.24.13-FlexBoot-3.6.403.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900257","Version":"16.31.1014"},{"DeviceName":"HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_31_1014-872725-B21_Ax_Bx-UEFI-14.24.13-FlexBoot-3.6.403.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900255","Version":"16.31.1014"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains utilities and binaries for upgrading firmware on HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter (HPE Part# 843400-B21), HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter (HPE Part# 872723-B21), HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter (HPE Part# 872725-B21) on Linux x86_64 platform."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>InfiniBand Card Type</td>\n\t\t\t<td>Firmware&nbsp;Version</td>\n\t\t\t<td>PSID</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter (843400-B21)</td>\n\t\t\t<td>12.28.2006</td>\n\t\t\t<td>\n\t\t\t<p>HPE2920111032</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter (872723-B21)</td>\n\t\t\t<td>16.31.1014</td>\n\t\t\t<td>HPE0000000017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter (872725-B21)</td>\n\t\t\t<td>16.31.1014</td>\n\t\t\t<td>HPE0000000008</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"7314610","datemodified":"2021-09-06T06:22:18","file_list":["./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.8-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.8-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.8-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.8-1.1/CP047566.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.8-1.1/getmlnxinfo","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.8-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.8-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.8-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.8-1.1/nic_fw/fw-ConnectX4-rel-12_28_2006-843400-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.8-1.1/nic_fw/fw-ConnectX5-rel-16_31_1014-872723-B21_Ax-UEFI-14.24.13-FlexBoot-3.6.403.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.8-1.1/nic_fw/fw-ConnectX5-rel-16_31_1014-872725-B21_Ax_Bx-UEFI-14.24.13-FlexBoot-3.6.403.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.8-1.1/nic_fw/mstflint","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.8-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.8-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP047566.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP047566.scexe"],"md5sum":"701ae53f4644a0f34f1387d217c1d4a9","name":"firmware-nic-mellanox-ib-cx4-cx5-1.0.8-1.1.x86_64.rpm","release":"2021-09-06T06:17:46","revision":"0","sha1sum":"1af5f55386bb2bae341e2065fed764d318513b24","size":"6MB","target_guids":["a6b1a447-382a-5a4f-15B3-1013159000EF","a6b1a447-382a-5a4f-15B3-101715900257","a6b1a447-382a-5a4f-15B3-101715900255"],"type_of_change":"1","version":"1.0.8"}],"id":{"product":"f148b53c7b96447699a0d01706827644","version":"65ce6154195645468dfcadb7238356e2"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Updating firmware with rpm installed:</strong></p>\n\n<ul>\n\t<li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li>\n\t<li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li>\n\t<li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li>\n</ul>\n\n<p><strong>Updating firmware without installing rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li>\n\t<li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Mellanox IB only ConnectX4 and ConnectX5 devices on Linux x86_64 platform"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"1013","subdev":"00EF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000ef","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0257","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900257","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0255","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900255","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-16T06:33:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 12.28.1002:</strong></p>\n\n<p>843400-B21 (HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter)<br />\n<br />\n<strong>New Feature and Changes in Version 12.28.1002:</strong></p>\n\n<ul>\n\t<li>Increased the maximum XRQ number to 512.</li>\n</ul>\n\n<p><br />\n<strong>Firmware for the following devices are updated to 16.29.1016:</strong></p>\n\n<p>872723-B21 (HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter)<br />\n872725-B21 (HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter)<br />\n&nbsp;</p>\n\n<p><strong>New Feature and Changes in Version 16.29.1016:</strong></p>\n\n<p>Added support for following features:</p>\n\n<ul>\n\t<li>Changed the default value of DCQCN&#39;s (Data center- Quantized Congestion Notification) NP parameter min_time_between_cnps to 4 on all devices to support larger scalability of the cluster.</li>\n\t<li>An option to allow applications to build their own QoS tree over the NIC hierarchy by connecting QPs to responder/requestor Queue Groups.</li>\n\t<li>&quot;InfiniBand&quot; properties set to the Network Device Function Redfish object.</li>\n\t<li>HW support for Flow Metering to utilize Advanced Steering Operation (ASO).&nbsp;HW Flow Meter allows higher scale, more accuracy, and better performance compared to the FW Flow Metering.</li>\n\t<li>Trust level for VFs. Once the VF is trusted, it will get a set of trusted capabilities.</li>\n\t<li>2 new Mini CQE formats: Responder Mini CQE With Flow Tag Layout Responder Mini CQE With l3_l4_info Layout</li>\n\t<li>UCX can now enable AR by exposing Out-Of-Ordering bitmask per SL with &quot;ooo_per_sl&quot; field in the HCA_VPORT context. It can be also queried by running the QUERY_HCA_VPORT_CONTEXT&nbsp;command.</li>\n\t<li>Steering DP hash flow groups.</li>\n\t<li>A new counter per vPort that counts the number of packets that reached the Ethernet RQ but cannot fit into the WQE due to their large size. Additionally, we added the option to control if such packet will cause &ldquo;CQE with Error&rdquo; or &ldquo;CQE_MOCK&rdquo;.</li>\n\t<li>PCIe Rx modifications to prevent the adapter cards from disappearing from the system.</li>\n\t<li>ignore_flow_level is now enabled by the TRUST LEVEL access registry.&nbsp;</li>\n\t<li>cq_overrun counter. The counter represents the number of times CQs enter an error state due to overflow that occur when the device tries to post a CQE into a full CQ buffer.</li>\n\t<li>[Beta]&nbsp;Enabled the capability to allow Virtual Functions to send Pause Frames packets.</li>\n\t<li>Enabled 10/25GbE auto-sensing with 3rd party when using 10/25GbE optical cables.</li>\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Following issues have been fixed in firmware version 16.29.1016:</strong></p>\n\n<ul>\n\t<li>An issue that prevented&nbsp;VXLAN packets with svlan/ cvlan tag from being matched.</li>\n\t<li>An issue that caused the&nbsp;eth_wqe_too_small counter to count&nbsp;ODP (On-Demand Paging) page faults.</li>\n\t<li>When MKEY_BY_NAME was enabled by NVCONFIG and a large number of VFs are configured, VM restart (VF/PF FLR) will take longer than when MKEY_BY_NAME is disabled.</li>\n\t<li>&nbsp;Ani ssue that resulted in low performance after enabling the RoCE Accelerator capability. Note:&nbsp;The fix is available when all ports are set as Ethernet.&nbsp;</li>\n\t<li>On rare cases, a fatal error related to errors from the PCI transport layer might be reported during FLR.</li>\n\t<li>The chassis manager calculation for Multi-Host and Socket-Direct adapter cards to allow running NC-SI commands by the chassis manager BMC. Now the chassis manager is count as BMC with index 0, regardless of how many BMC there are.</li>\n\t<li>An issue that caused&nbsp;the device to go to down IRISC as one of the firmware semaphores could not be released&nbsp;when a speed change or port state change was triggered.&nbsp;</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 12.28.1002:</strong></p>\n\n<ul>\n\t<li>An issue that caused the DCR (DC Resources) to be destroyed before the retry option managed to work when the retry timeout is too big. in this case, the DCR&#39; time-to-live was increased, and the maximum retry timeout was decreased.</li>\n\t<li>Increased PHY power consumption limit to 1.5w.</li>\n\t<li>An issue that caused PortCounters.PortRcvErr / PPCNT.infiniband_counters.PortRcvErr not to report port icrc errors.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 12.28.2006:</strong></p>\n\n<p style=\"margin-left:40px\">843400-B21 (HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter)<br />\n&nbsp;</p>\n\n<ul>\n</ul>\n\n<p><strong>Firmware for the following devices are updated to 16.31.1014:</strong></p>\n\n<p style=\"margin-left:40px\">872723-B21 (HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter)<br />\n872725-B21 (HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter)</p>\n\n<p>&nbsp;</p>\n\n<p><strong>New features and changes in version 12.28.2006:</strong></p>\n\n<ul>\n\t<li>Increased the maximum XRQ number to 512.</li>\n</ul>\n\n<p><strong>New features and changes in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>NIC scheduling feature support has been disabled for non-privileged functions.</li>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Asymmetrical MSIX Configuration: This feature allows the device to be configured with a different number of MSIX vectors per physical PCI functions.To use this feature, please follow these steps:</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Clear NUM_PF_MSIX_VALID to disable global symmetrical MSIX configuration.</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Set PF_NUM_PF_MSIX_VALID to enable asymmetrical per Physical Function MSIX configuration.</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Configure PF_NUM_PF_MSIX per physical PCI function.</li>\n\t<li>RDMA partitioning and RDMA counters in IB mode.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.</li>\n\t<li>Enabled UID 0 to create resources with UMEM (User Memory).</li>\n\t<li>Receiving and sending native IB packets from/to the software (including all headers) via raw IBL2 QPs.</li>\n\t<li>RX RDMA NIC flow table on an IB port. Now the software can steer native IB packets to raw IB receive queues according to the DLID and &nbsp;the DQPN.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 12.28.2006:</strong></p>\n\n<ul>\n\t<li>An issue that caused the DCR (DC Resources) to be destroyed before the retry option managed to work when the retry timeout is too big. in this case, the DCR&#39; time-to-live was increased, and the maximum retry timeout was decreased.</li>\n\t<li>Increased PHY power consumption limit to 1.5w.</li>\n\t<li>An issue that caused PortCounters.PortRcvErr / PPCNT.infiniband_counters.PortRcvErr not to report port icrc errors.</li>\n</ul>\n\n<p><strong>The following issues have been fixed in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>An assert that was caused when trying to open 1024 functions on the device and the maximum number of functions was 1023.</li>\n\t<li>Occasional performance issues related to RC QPs using E2E-credits (not connected to SRQ and doing send/receive traffic) when the ROCE_ACCL tx_window was enabled.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>A rare issue that caused RX pipe to hang.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>An issue that caused the TX queue to get into an unresponsive state when the VF rate limiter was set.</li>\n</ul>\n\n<p style=\"margin-left:40px\"><strong>Additional Fixes included in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li style=\"margin-left: 40px;\">Disabled the CNP counter &ldquo;rp_cnp_ignored &quot; (triggered by OOS (out-of-sequence)) when all ports are IB.</li>\n\t<li style=\"margin-left: 40px;\">Fixed the TMP421 sensor temperature reporting.</li>\n\t<li style=\"margin-left: 40px;\">Fixed the rate select mechanism in QSFP modules.</li>\n\t<li style=\"margin-left: 40px;\">Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li style=\"margin-left: 40px;\">Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U27","value":"HPE ProLiant XL2x260w Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_IB_CX4_CX5","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"The HPE Storage Fibre Channel (FC) adapter kit contains version 12.8.351.7 of the Emulex Storport driver for Extended Systems which provides Mezzanine Fibre Channel-Host Bus Adapter (HBA) driver support for HPE Storage RAID Arrays."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"2309240","datemodified":"2021-08-27T11:09:30","file_list":["cp048581.xml","cpqsetup.exe","elxdrvr-fc-12.8.351.7-13.exe","ElxStorInstaller.dll","install.xml","SysConfig.frm","SysConfig.frm.ja"],"md5sum":"fe6f56fa950817042f2e5922d7568a81","name":"cp048581.exe","release":"2021-08-27T11:06:58","revision":"0","sha1sum":"d10f60499774cffb34d5b3dd1219092cd4876750","size":"2MB","target_guids":[],"type_of_change":"1","version":"12.8.351.7"}],"id":{"product":"2d2d3aff681a4661bfbd7a6901361815","version":"d2d3f3cdee964f66a64c78185908a82a"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation.</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Mezzanine Fibre Channel Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T09:15:49","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to driver version&nbsp;12.8.351.7</p>\n\n<p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p>\n\n<p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p>\n\n<p>The extracted files are located:</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p>\n\n<p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2019</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"elxfc.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000800JWZJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3830-304a575a4a50","Version":"HPD4"},{"DeviceName":"VO001600JWZJQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3630-304a575a4a51","Version":"HPD4"},{"DeviceName":"VO003200JWZJR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3230-304a575a4a52","Version":"HPD4"},{"DeviceName":"VO006400JWZJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3630-3430-304a575a4a54","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO000800JWZJP、VO001600JWZJQ、VO003200JWZJRおよびVO006400JWZJT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp;&nbsp; </strong>None</p>\n"}],"files":[{"bytes":"3198080","datemodified":"2021-07-26T06:00:31","file_list":["cp048468.xml","cpqsetup.exe","GPM1645ASAD4.rel","payload.json","setup.dll"],"md5sum":"2b95f4eca770346c00d39cc465df9e98","name":"cp048468.exe","release":"2021-07-26T05:53:04","revision":"0","sha1sum":"fa8471a1065f5475b958db8fd715c95c253b8711","size":"3MB","target_guids":["562340a5-304f-3030-3830-304a575a4a50","562340a5-304f-3130-3630-304a575a4a51","562340a5-304f-3330-3230-304a575a4a52","562340a5-304f-3630-3430-304a575a4a54"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"38d3787c49804ab1b404f61b3cd58354","version":"feaec5b8282a4ad787dfe0e69874f5b0"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows(x64) - VO000800JWZJP、VO001600JWZJQ、VO003200JWZJRおよびVO006400JWZJTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VO006400JWZJT","target_guid":"562340a5-304f-3630-3430-304a575a4a54","type":"sas"},{"id":"VO003200JWZJR","target_guid":"562340a5-304f-3330-3230-304a575a4a52","type":"sas"},{"id":"VO001600JWZJQ","target_guid":"562340a5-304f-3130-3630-304a575a4a51","type":"sas"},{"id":"VO000800JWZJP","target_guid":"562340a5-304f-3030-3830-304a575a4a50","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T13:27:09","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Modify Drive Vendor Identification String (VID) in Inquiry page from &ldquo;HP&rdquo; to &ldquo;HPE&rdquo;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO000800JWZJP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003200JWZJR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001600JWZJQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO006400JWZJT","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400JWDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57444b50","Version":"HPD2"},{"DeviceName":"EO000800JWDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57444b51","Version":"HPD2"},{"DeviceName":"EO001600JWDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57444b52","Version":"HPD2"},{"DeviceName":"MO000400JWDKU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57444b55","Version":"HPD2"},{"DeviceName":"MO000800JWDKV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57444b56","Version":"HPD2"},{"DeviceName":"MO001600JWDLA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57444c41","Version":"HPD2"},{"DeviceName":"MO003200JWDLB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57444c42","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EO000400JWDKP、EO000800JWDKQ、EO001600JWDKR、MO000400JWDKU、MO000800JWDKV、 MO001600JWDLA および MO003200JWDLB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD1<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3747760","datemodified":"2021-07-24T05:09:23","file_list":["cp048555.xml","cpqsetup.exe","HBCMSssseFD2.rel","payload.json","setup.dll"],"md5sum":"433342b71b76ab3642fe40b050eafc6f","name":"cp048555.exe","release":"2021-07-24T05:01:05","revision":"0","sha1sum":"b746b0f2c5ba2addd2ab42a7d076ae74e3f6d8b5","size":"3MB","target_guids":["452340a5-304f-3030-3430-304a57444b50","452340a5-304f-3030-3830-304a57444b51","452340a5-304f-3130-3630-304a57444b52","4d2340a5-304f-3030-3430-304a57444b55","4d2340a5-304f-3030-3830-304a57444b56","4d2340a5-304f-3130-3630-304a57444c41","4d2340a5-304f-3330-3230-304a57444c42"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"ae8b95207bc948489c851dd62c16f373","version":"c2d88e486e524711af6f115eb63d5750"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EO000400JWDKP、EO000800JWDKQ、EO001600JWDKR、MO000400JWDKU、MO000800JWDKV、MO001600JWDLA、およびMO003200JWDLBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EO001600JWDKR","target_guid":"452340a5-304f-3130-3630-304a57444b52","type":"sas"},{"id":"MO001600JWDLA","target_guid":"4d2340a5-304f-3130-3630-304a57444c41","type":"sas"},{"id":"MO003200JWDLB","target_guid":"4d2340a5-304f-3330-3230-304a57444c42","type":"sas"},{"id":"EO000400JWDKP","target_guid":"452340a5-304f-3030-3430-304a57444b50","type":"sas"},{"id":"MO000400JWDKU","target_guid":"4d2340a5-304f-3030-3430-304a57444b55","type":"sas"},{"id":"EO000800JWDKQ","target_guid":"452340a5-304f-3030-3830-304a57444b51","type":"sas"},{"id":"MO000800JWDKV","target_guid":"4d2340a5-304f-3030-3830-304a57444b56","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T05:13:36","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EO000400JWDKP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600JWDLA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000800JWDKQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000400JWDKU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200JWDLB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800JWDKV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO001600JWDKR","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6311518","datemodified":"2021-05-18T04:26:18","file_list":["./usr/lib/i386-linux-gnu/firmware-system-u20-2.90_2021_04_29-1.1","./usr/lib/i386-linux-gnu/firmware-system-u20-2.90_2021_04_29-1.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-system-u20-2.90_2021_04_29-1.1/.setup","./usr/lib/i386-linux-gnu/firmware-system-u20-2.90_2021_04_29-1.1/CP047838.xml","./usr/lib/i386-linux-gnu/firmware-system-u20-2.90_2021_04_29-1.1/U20_2.90_04_29_2021.signed.flash","./usr/lib/i386-linux-gnu/firmware-system-u20-2.90_2021_04_29-1.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-system-u20-2.90_2021_04_29-1.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP047838.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP047838.scexe"],"md5sum":"a1e74aa1e9f308e5a6477cbbf2c0d9ca","name":"firmware-system-u20-2.90_2021_04_29-1.1.i386.rpm","release":"2021-05-18T04:14:12","revision":"0","sha1sum":"2723ba429e16d3cf8b533bfe33c3ee1deb30bf75","size":"6MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021"}],"id":{"product":"5a6728d6569a49b58900b480fe0325b7","version":"40400d9b54b44582846865c6b6a4efab"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HPE ProLiant Agentless Management Service (<strong>AMS</strong>) and HPE SNMP Agents (<strong>SNMP Agents</strong>) are both running.&nbsp; HPE does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager 8.0.0 or later, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、iLOとの通信ができない場合に失敗します。  これは、HPE ProLiant Agentless Management Service (<strong>AMS</strong>)およびHPE SNMPエージェント(<strong>SNMP Agents</strong>)の両方が実行されているときに発生します。  HPEでは、AMSおよびSNMPエージェントを同時に実行させないことを推奨します。  「iLO device not found」エラーが発生した場合、AMSまたはSNMPエージェントを停止させて、再度フラッシュコンポーネントを実行します。<br />\n<br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上のSmart Update Manager 8.0.0以降を使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant DL160 Gen9/DL180 Gen9 (U20) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant DL160 Gen9/DL180 Gen9（U20）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Oracle Linux 6 (AMD64/EMT64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Oracle Linux 7","platform":"Oracle Enterprise Linux","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-05T03:27:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"}],"sw_keys":[{"name":"U20","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900374","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the boot BIOS and firmware of HPE QLogic Mezzanine Fibre Channel host bus adapters."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"8750357","datemodified":"2021-08-25T12:06:11","file_list":["/CP048712_BUILD_2.data","/CP048712.vmexe","/CP048712.vmexe64","/CP048712.vmfile","/CP048712_VMw.zip","/CP048712.xml","/payload.json","/CP048712_VMw.zip/index.xml","/CP048712_VMw.zip/vendor-index.xml","/CP048712_VMw.zip/metadata.zip","/CP048712_VMw.zip/vib20/CP048712/HPE_bootbank_CP048712_2021.09.01.2-6.7.0.7535516.vib","/CP048712_VMw.zip/metadata.zip/vendor-index.xml","/CP048712_VMw.zip/metadata.zip/vmware.xml","/CP048712_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048712_2021.09.01.2-6.7.0.7535516.xml","/CP048712_VMw.zip/metadata.zip/vibs/CP048712-4461103236065074170.xml"],"md5sum":"23c291832e00fbc22694a38d604d772c","name":"CP048712.zip","release":"2021-08-25T12:00:04","revision":"0","sha1sum":"6484ce1b25ff0f5a3d4d9bec73121142bf7f1d40","size":"8MB","target_guids":[],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"CP048712","version":"2021.09.01.2-6.7.0.7535516"}]}],"id":{"product":"8ba3637a348442a6baf1f22440c65d78","version":"574465ad11e743e18d62b8c94caca1c3"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated if the ESXi host is Gen9 Server or Enter the IP or DNS address of the iLO of the ESXi host if the Sever is Gen10 and above</li>\n\t<li>Enter the ESXi host/iLO credentials (root or administrator username and password) based on Gen9/Gen10 and above</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for QLogic Mezzanine Fibre Channel Host Bus Adapters for VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-18T06:27:16","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated&nbsp;the Firmware/BIOS/UEFI packages for&nbsp;16 Gb&nbsp;products.</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>MBI</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE QMH2672 16Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>6.04.04</td>\n\t\t\t<td>8.08.232</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.43</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"QLOGIC","sw_key_expectedpath":"firmware:QLOGIC"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the iSCSI driver for the HPE Blade Emulex 10/20Gb Server Adapters for Windows Server 2016."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"914144","datemodified":"2019-10-24T22:59:11","file_list":["be2iscsi.cat","be2iscsi.inf","be2iscsi.sys","bepiscsi.dll","cp039931.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"md5sum":"746411ce6afcc96d398b2e6a03c2d62c","name":"cp039931.exe","release":"2019-10-24T21:44:03","revision":"0","sha1sum":"d8ae6b9adf201fbafe1672a6b0dea792c36bc509","size":"892KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec037c8524"],"type_of_change":"0","version":"12.0.1171.0"}],"id":{"product":"9017d5d393b24dab905e04b38c0d82f3","version":"e176eabb9c134c88ae1e0d1f591d5735"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE iSCSI Driver for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"320"},"supported_devices":[{"dev":"0722","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-11-08T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"be2iscsi.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH0600JDYTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFL4CD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3630-304a4459544e","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: EH0600JDYTN"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EH0600JDYTN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EH0600JDYTN Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Fixes a data integrity risk where stale data is mistakenly used from cache.</li>\n\t<li>Fixes a data integrity risk where stale data is returned on an unaligned overlapped write-read operation.</li>\n\t<li>Fixes a data integrity risk during a sequential read and write workload when a recovered error is encountered, which could cause incomplete data to be read.&nbsp;</li>\n</ul>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None.</p>\n"}],"files":[{"bytes":"17533698","datemodified":"2021-08-30T07:19:49","file_list":["/CP048294_BUILD_2.data","/CP048294.vmexe","/CP048294.vmexe64","/CP048294.vmfile","/CP048294_VMw.zip","/CP048294.xml","/payload.json","/CP048294_VMw.zip/index.xml","/CP048294_VMw.zip/vendor-index.xml","/CP048294_VMw.zip/metadata.zip","/CP048294_VMw.zip/vib20/CP048294/HPE_bootbank_CP048294_HPD7.2-7.0.0.15843807.vib","/CP048294_VMw.zip/metadata.zip/vendor-index.xml","/CP048294_VMw.zip/metadata.zip/vmware.xml","/CP048294_VMw.zip/metadata.zip/vibs/CP048294-7789547198463790500.xml","/CP048294_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048294_HPD7.2-7.0.0.15843807.xml"],"md5sum":"cee9e2f669976dbddd5df382bacf1d49","name":"CP048294.zip","release":"2021-08-30T07:14:48","revision":"0","sha1sum":"4e5a0c69aa8e23b800cb25467adaa2ffb4479983","size":"16MB","target_guids":["002340a5-4500-3048-3630-304a4459544e"],"type_of_change":"2","version":"HPD7","vib_list":[{"name":"CP048294","version":"HPD7.2-7.0.0.15843807"}]}],"id":{"product":"ce1fbf38afa940d590b86cded0a4b8a1","version":"7255b73afb334813b61a9ca22df050c5"},"installation":{"command":"CP040688.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - EH0600JDYTN Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EH0600JDYTNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EH0600JDYTN","target_guid":"002340a5-4500-3048-3630-304a4459544e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-03T08:41:49","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Fixes a data integrity risk where stale data is mistakenly used from cache.</li>\n\t<li>Fixes a data integrity risk where stale data is returned on an unaligned overlapped write-read operation.</li>\n\t<li>Fixes a data integrity risk during a sequential read and write workload when a recovered error is encountered, which could cause incomplete data to be read.ÃÂ </li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Fixes a data integrity risk where stale data is mistakenly used from cache.</li>\n\t<li>Fixes a data integrity risk where stale data is returned on an unaligned overlapped write-read operation.</li>\n\t<li>Fixes a data integrity risk during a sequential read and write workload when a recovered error is encountered, which could cause incomplete data to be read.ÃÂ </li>\n</ul>","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH0600JDYTN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800026","languages":[{"lang":"tw","x_late":"軟體 - 管理"},{"lang":"en","x_late":"Software - Management"},{"lang":"ko","x_late":"소프트웨어 - 관리"},{"lang":"ja","x_late":"ソフトウェア - マネジメント"},{"lang":"cn","x_late":"软件 - 管理"}]}],"description":[{"lang":"en","x_late":"The Smart Storage Administrator CLI is a commandline-based disk configuration program for Smart Array Controllers and SmartRAID Controllers. "}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"7495896","datemodified":"2021-03-18T15:14:33","file_list":["/cp047031.xml","/hpessacli-component_5.10.45.1-7.0.0_17771110.zip","/hpessacli-component_5.10.45.1-7.0.0_17771110.zip/index.xml","/hpessacli-component_5.10.45.1-7.0.0_17771110.zip/vendor-index.xml","/hpessacli-component_5.10.45.1-7.0.0_17771110.zip/metadata.zip","/hpessacli-component_5.10.45.1-7.0.0_17771110.zip/vib20/hpessacli/MIS_bootbank_hpessacli_5.10.45.1-7.0.0.15525992.oem.vib","/hpessacli-component_5.10.45.1-7.0.0_17771110.zip/metadata.zip/vendor-index.xml","/hpessacli-component_5.10.45.1-7.0.0_17771110.zip/metadata.zip/vmware.xml","/hpessacli-component_5.10.45.1-7.0.0_17771110.zip/metadata.zip/vibs/hpessacli-1653002473151447380.xml","/hpessacli-component_5.10.45.1-7.0.0_17771110.zip/metadata.zip/bulletins/hpessacli-component_5.10.45.1-7.0.0.xml"],"md5sum":"cab759a7fdc45788f118568dff963294","name":"cp047031.zip","release":"2021-03-18T15:12:08","revision":"0","sha1sum":"e38efef5efc3b3e28524b61fe295cee7dcd56a13","size":"7MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec23d0c2b9","20a6e8e4-bf33-4c71-a6bf-d9ecc5c305d1"],"type_of_change":"1","version":"2021.04.01","vib_list":[{"name":"hpessacli","version":"5.10.45.1-7.0.0.15525992.oem"}]}],"id":{"product":"91a15c09dbd5425fbdb19fbefcf76977","version":"fc189eb7b32a49e485a32e6a9194d91f"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To&nbsp;install this bundle using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the component zip file to extract the driver offline bundle.</li>\n\t<li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li>\n</ol>\n\n<p>Refer to VMware documentation for information on the esxcli commands</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Smart Storage Administrator (SSA) CLI Smart Component for ESXi 7.0 "}],"prerequisites":{"required_diskspace":{"size_kb":"7100"},"supported_devices":[{"dev":"A256","subdev":"02F4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a256159002f4","type":"pci","ven":"8086"},{"dev":"A206","subdev":"02F2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a206159002f2","type":"pci","ven":"8086"},{"dev":"193F","subdev":"027F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-193f1590027f","type":"pci","ven":"103C"},{"dev":"028F","subdev":"02DC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-9005-028f159002dc","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0294","subven":"1590","target_guid":"a6b1a447-382a-5a4f-9005-028f15900294","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1100","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1100","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0655","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0655","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0601","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0601","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1101","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1101","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0602","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0602","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0603","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0603","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0600","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0600","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0701","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0701","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0700","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0700","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0651","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0651","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0654","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0654","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0652","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0652","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0650","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0650","type":"pci","ven":"9005"},{"dev":"A186","subdev":"00E5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a186159000e5","type":"pci","ven":"8086"},{"dev":"193F","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-193f159000e4","type":"pci","ven":"103C"},{"dev":"A1D6","subdev":"00E6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a1d6159000e6","type":"pci","ven":"8086"},{"dev":"A206","subdev":"00E5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a206159000e5","type":"pci","ven":"8086"},{"dev":"A256","subdev":"00E6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a256159000e6","type":"pci","ven":"8086"},{"dev":"3239","subdev":"21cc","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21cc","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21CD","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21cd","type":"pci","ven":"103c"},{"dev":"A106","subdev":"00C0","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a106159000c0","type":"pci","ven":"8086"},{"dev":"A107","subdev":"00C0","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a107159000c0","type":"pci","ven":"8086"},{"dev":"3239","subdev":"21ce","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21ce","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cb","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21cb","type":"pci","ven":"103c"},{"dev":"8D66","subdev":"009D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-8d661590009d","type":"pci","ven":"8086"},{"dev":"8D06","subdev":"009C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-8d061590009c","type":"pci","ven":"8086"},{"dev":"193F","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-193f103c3381","type":"pci","ven":"103C"},{"dev":"3239","subdev":"21c5","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c5","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c1","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c1","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21be","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21be","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c3","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c3","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c0","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c0","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c2","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ca","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21ca","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21BD","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21bd","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c4","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c4","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c9","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c9","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c8","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c8","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21bf","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21bf","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c7","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c7","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c6","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c6","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-05T14:04:08","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Adding support&nbsp;to the HPE&nbsp;SR Gen10 Plus&nbsp;Controllers.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U38","value":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"","value":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"Carbondale14","value":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U14","value":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4520 Gen9 Chassis</p>\n"},{"key":"U27","value":"HPE ProLiant XL2x260w Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"","value":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>\n"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"","value":"HPE ProLiant ML150 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U38","value":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"","value":"HPE ProLiant XL770f Gen9 Server"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"hpessacli:5.10.45.1-7.0.0.15525992.oem","sw_key_expectedpath":"software:vmware:zip"},{"name":"hpessacli-component:5.10.45.1-7.0.0","sw_key_expectedpath":"software.component:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Intel ixgbe Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Intel ixgbe Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"4202043","datemodified":"2021-01-09T01:55:19","file_list":["./etc/depmod.d/hp-ixgbe.conf","./etc/dracut.conf.d/hp-ixgbe-oob.conf","./lib/modules/4.12.14-195-default","./lib/modules/4.12.14-195-default/updates","./lib/modules/4.12.14-195-default/updates/hp-ixgbe","./lib/modules/4.12.14-195-default/updates/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/hp-ixgbe-kmp-default/component.xml"],"md5sum":"d1f70e5e63da2fda09436a12f425d73a","name":"hp-ixgbe-kmp-default-5.9.4_k4.12.14_195-1.sles15sp1.x86_64.rpm","release":"2021-01-09T01:41:06","revision":"0","sha1sum":"5fa47f6c761b6dcfdb1e37dffe942e9668156bd8","size":"4MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec22d08a36"],"type_of_change":"0","version":"5.9.4-1"},{"bytes":"4991618","datemodified":"2021-01-09T01:48:23","file_list":["./etc/depmod.d/hp-ixgbe.conf","./etc/dracut.conf.d/hp-ixgbe-oob.conf","./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/hp-ixgbe","./lib/modules/5.3.18-22-default/updates/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/hp-ixgbe-kmp-default/component.xml"],"md5sum":"d1651a61c2617b38617329e54b764119","name":"hp-ixgbe-kmp-default-5.9.4_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-01-09T01:41:06","revision":"0","sha1sum":"86dc6251243e1624cfc93a22e082c9d6a081fc9c","size":"4MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec22d08a36"],"type_of_change":"0","version":"5.9.4-1"}],"id":{"product":"3ab4de78da484144892d6ddcd8fd9b97","version":"7cba14b9508d40b3ae58ccf25ec8ceea"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>Download README for any additional installation instructions.</p>\n"},{"lang":"ja","x_late":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>\n\n<p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>\n\n<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>\n\n<p> </p>\n\n<p>その他のインストール手順についてのREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Intel ixgbe Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE Intel ixgbeドライバーfor SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c192d","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c211a","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"},{"dev":"152E","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d3","type":"pci","ven":"8086"},{"dev":"1530","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"1515","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c192d","type":"pci","ven":"8086"},{"dev":"1515","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c211a","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product update Linux kernel documentation and Configure IRQ affinity tools</p>\n","latest_fixes_x_late":"<p>This product corrects an issue which errata kernel loads inbox driver instead of this component after booting into OS</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>This product now supports Suse Linux Enterprise Server 15 Service Pack 2</li>\n\t<li>This product enhances reliability via adding support for new mailbox communication between PF(Physical Function) and VF(Virtual Function) and remove its potential flaws that may lead to the undefined or faulty behavior</li>\n\t<li>This product enhances compatibility where new mailbox api implementation is alo compatible with old drivers</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"hp-ixgbe-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbe-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbe-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbe-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Blade QLogic NX2 10Gb and 20Gb Multifunction Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 12."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12で動作するHPE Blade QLogic NX2 10Gbおよび20GbマルチファンクションGigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"6397387","datemodified":"2021-08-16T16:57:29","file_list":["./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/bnx2.ko","./lib/modules/4.12.14-120-default/updates/bnx2fc.ko","./lib/modules/4.12.14-120-default/updates/bnx2i.ko","./lib/modules/4.12.14-120-default/updates/bnx2x.ko","./lib/modules/4.12.14-120-default/updates/cnic.ko","./usr/share/smartupdate/netxtreme2_bl-kmp-default/component.xml"],"md5sum":"507b5beb5af982bec3350b1fe0a273dd","name":"netxtreme2_bl-kmp-default-7.14.80_k4.12.14_120-5.sles12sp5.x86_64.rpm","release":"2021-08-16T16:40:04","revision":"0","sha1sum":"ab972c9f35dc2c6d6fa9a6af76caf5df07ca0e85","size":"6MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3da3feeb"],"type_of_change":"0","version":"7.14.80-5"}],"id":{"product":"6f63395ea958425f83bb31303381afd1","version":"d687baf1f76b4e73b726b31a7cdde904"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for SUSE Linux Enterprise Server 12"},{"lang":"ja","x_late":"HPE Blade QLogic NX2 10/20 GbEマルチファンクションドライバーfor SUSE Linux Enterprise Server 12"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"168E","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1933","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c22fa","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1917","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1916","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1933","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1916","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1917","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c22fa","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1933","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c22fa","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1916","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1917","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-09-03T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 12 SP5.</p>\n","latest_fixes_x_late":"<p>This product corrects an issue where the driver fails to load in NPAR mode when RoCE Data Center Quantized Congestion Notification (DCQCN) is enabled.<br />\nThis product addresses a system crash seen when unloading and reloading the RoCE driver only.<br />\nThis product addresses a system crash seen during multiple reboots of virtual machines using VFs and RDMA.<br />\nThis product addresses a system crash seen when injecting a fw_assert on a NIC PF.<br />\nThis product corrects an issue where a system fails to shutdown after reboots in iSCSI BFS.</p>\n"},{"curr_enhancements_x_late":"<p>This product is updated to maintain compatibility with firmware version 1.5.x.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"netxtreme2_bl-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains iSCSI drivers for the HPE Emulex 10/20GbE Server Adapters running under SUSE Linux Enterprise Server 12 x86_64."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12 x86_64で動作するHPE Emulex 10/20GbEサーバーアダプター用のiSCSIドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"892700","datemodified":"2021-01-14T08:29:02","file_list":["./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/be2iscsi","./lib/modules/4.12.14-120-default/updates/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/be2iscsi-kmp-default/component.xml"],"md5sum":"1957e512d762d485d15167e516341024","name":"be2iscsi-kmp-default-12.0.1342.0_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-01-14T07:55:05","revision":"0","sha1sum":"44f845ff564809965b476481a94e287f18c82493","size":"871KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecdaa9949b"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"870976","datemodified":"2021-01-14T08:15:11","file_list":["./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/be2iscsi","./lib/modules/4.12.14-94.41-default/updates/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/be2iscsi-kmp-default/component.xml"],"md5sum":"09216072a0e70cfcbfbe2202bfa800db","name":"be2iscsi-kmp-default-12.0.1342.0_k4.12.14_94.41-1.sles12sp4.x86_64.rpm","release":"2021-01-14T07:55:05","revision":"0","sha1sum":"bb47fb22cf0b2e51bf11aab8289e7e2799a8ab53","size":"850KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecdaa9949b"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"1e813f94062740e78e298970d25a3203","version":"058d8b512c4e4243a6a2850b0e861ad7"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Emulex 10/20GbE iSCSI Drivers for SUSE Linux Enterprise Server 12 x86_64"},{"lang":"ja","x_late":"HPE Emulex 10/20GbE iSCSI ドライバー for SUSE Linux Enterprise Server 12 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0728","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c8144","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c21d4","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072215908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c220a","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 12 Service Pack 5</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"be2iscsi-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2iscsi-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2iscsi-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2iscsi-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300032","languages":[{"lang":"fr","x_late":"Pilote - Gestion du système"},{"lang":"en","x_late":"Driver - System Management"},{"lang":"cn","x_late":"驱动程序 - 系统管理"},{"lang":"tw","x_late":"驅動程式 ─ 系統管理"},{"lang":"de","x_late":"Treiber - Systemverwaltung"},{"lang":"ko","x_late":"드라이버 - 시스템 관리"},{"lang":"it","x_late":"Driver - Gestione sistema"},{"lang":"ja","x_late":"ドライバ - システム マネジメント"},{"lang":"es","x_late":"Controlador - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The iLO 4 Channel Interface Driver allows software to communicate with the  iLO 4 management controller.  The driver is used by the ProLiant Health Monitor, Insight Management Agents and WBEM Providers, Agentless Management Service, and other utilities."},{"lang":"ja","x_late":"iLO 4 チャネルインターフェイスドライバーは、iLO 4マネジメントコントローラーとの通信を行うことを可能にするソフトウェアです。ドライバーは、ProLiant Health Monitor、Insightマネジメントエージェント、WBEMプロバイダー、Agentless Management Service、およびその他のユーティリティで使用されます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[],"files":[{"bytes":"970816","datemodified":"2019-07-19T13:44:30","file_list":["cp039984.xml","cpqsetup.exe","hpqilo3chif.cab","hpqilo3chif.msi","install.xml","multisetup.dll"],"md5sum":"f613ce12bcf5498234cb4fec367f7408","name":"cp039984.exe","release":"2019-07-19T13:43:02","revision":"0","sha1sum":"aa57be924969f6a134fb71abe5668b9b2237365d","size":"948KB","target_guids":[],"type_of_change":"0","version":"4.1.0.0"}],"id":{"product":"18101e2f386d4a08b577a4dbb3f10bb2","version":"391f0c310c924657a228daaf899c4102"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"tw","x_late":"將智慧型元件放在臨時目錄中，按兩下執行。<p>選擇「Install (安裝)」開始解壓縮至硬碟上的一個臨時位置。   <p>按一下「Install (安裝)」繼續進行驅動程式的安裝。"},{"lang":"en","x_late":"Place the Smart Component in a temporary directory, then double-click it to run.<p>Select \"Install\" to start extracting to a temporary location on the hard drive.   <p>Click the \"Install\" button to perform the driver installation."},{"lang":"ko","x_late":"스마트 구성 요소를 임시 디렉터리에 저장하고 이를 더블 클릭하여 실행합니다.<p>\"설치\"를 선택하여 하드 드라이브의 임시 디렉터리에 압축을 풉니다.   <p>\"설치\" 버튼을 클릭하여 드라이버 설치 작업을 시작합니다."},{"lang":"cn","x_late":"将智能组件置于临时目录中，然后双击运行。<p>选择“安装”，开始提取至硬盘的临时位置。   <p>点击“安装”按钮继续执行驱动程序安装。"},{"lang":"ja","x_late":"Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。<p>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。   <p>インストールボタンをクリックしてドライバーインストールを実行します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"iLO 4 Channel Interface Driver for Windows Server 2012 and Server 2012 R2"},{"lang":"ja","x_late":"iLO 4チャネルインターフェイスドライバー for Windows Server 2012 および Windows Server 2012 R2"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3307","subdev":"1979","subven":"103C","target_guid":"","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows 8.1 (64-bit)","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-09-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Aligned system and operating system support with the production Service Pack for ProLiant.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Corrected a potential Windows bugcheck 0x50 (PAGE_FAULT_IN_NONPAGED_AREA) that could occur if Windows restarts the driver without unloading it.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"}],"sw_keys":[{"name":"hpqilo3chif.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains iSCSI drivers for the HPE Blade Emulex 10/20GbE Server Adapters running under Red Hat Enterprise Linux 7."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7で動作するHPE Blade Emulex 10/20GbE サーバーアダプター用のiSCSIドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"954366","datemodified":"2021-03-08T18:00:27","file_list":["./etc/depmod.d/be2iscsi.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/be2iscsi","./lib/modules/3.10.0-1160.el7.x86_64/extra/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/kmod-be2iscsi_bl/component.xml"],"md5sum":"9fbe61d65c431f81c9be90ea4411938f","name":"kmod-be2iscsi_bl-12.0.1342.0-1.rhel7u9.x86_64.rpm","release":"2021-03-08T17:52:05","revision":"0","sha1sum":"0546c14ec984fd6a5be1158c3920cdcfbee5b2f6","size":"931KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb2fe523e"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"953499","datemodified":"2021-03-08T17:57:49","file_list":["./etc/depmod.d/be2iscsi.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/be2iscsi","./lib/modules/3.10.0-1127.el7.x86_64/extra/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/kmod-be2iscsi_bl/component.xml"],"md5sum":"6d7f1c3af7361bf93c309b2a77956caf","name":"kmod-be2iscsi_bl-12.0.1342.0-1.rhel7u8.x86_64.rpm","release":"2021-03-08T17:52:05","revision":"0","sha1sum":"963ca324b280912edc8713043fc0ccff922fb5e0","size":"931KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb2fe523e"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"72bb108f558244ddb21ec2debe092df6","version":"7731e7e28e18499896b56c654e829017"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE iSCSI Drivers for Red Hat Enterprise Linux 7"},{"lang":"ja","x_late":"HPE Blade Emulex 10/20GbE iSCSIドライバー for Red Hat Enterprise Linux 7"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0722","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>These drivers have been&nbsp;updated to maintain compatibility with the latest firmware.</p>\n","latest_fixes_x_late":"<p>These drivers have been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 7, Updates 8 and 9.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"kmod-be2iscsi_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2iscsi_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2iscsi_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2iscsi_bl","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5930264","datemodified":"2021-05-18T02:54:04","file_list":["P85_2.90_04_29_2021.signed.flash","SignedImageInstaller64.dll","cp047849.xml","cpqsetup.exe","cpqsysio64.sys"],"md5sum":"b855ece5bdd3b3ecd3336e338af74aa8","name":"cp047849.exe","release":"2021-05-18T02:37:13","revision":"0","sha1sum":"d1cb9ce0c4080ac216bda0782e2dc2f04416ff9e","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021"}],"id":{"product":"c740e1c15c784d9bb5ce0ea0e215f139","version":"1e8b540b9aa841ba9f5fda3357895027"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL560 Gen9 (P85) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant DL560 Gen9 (P85)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-05T03:50:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>Ver. 2.80_10-16-2020(B) contains updates to the firmware packaging and is functionally equivalent to ver. 2.80_10-16-2020. It is not necessary to upgrade with Revision B if a previous component revision was used to upgrade the firmware to version 2.80_10-16-2020.</p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"}],"sw_keys":[{"name":"P85","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900217","languages":[{"lang":"fr","x_late":"Micrologiciel - Infrastructure Blade"},{"lang":"en","x_late":"Firmware - Blade Infrastructure"},{"lang":"cn","x_late":"固件 - 刀片式架构"},{"lang":"tw","x_late":"韌體 ─ 刀鋒型基礎架構"},{"lang":"de","x_late":"Firmware - Blade-Infrastruktur"},{"lang":"ko","x_late":"펌웨어 - 블레이드 인프라"},{"lang":"it","x_late":"Firmware - Infrastruttura Blade"},{"lang":"ja","x_late":"ファームウェア - ブレード インフラストラクチャ"},{"lang":"es","x_late":"Firmware - Infraestructura Blade"}]}],"description":[{"lang":"en","x_late":"This Smart Component contains the firmware image for the HPE 6Gb SAS BL Switch. After downloading the component and extracting the firmware image to a directory, access the Virtual SAS Manager's GUI or CLI interface to flash the firmware."},{"lang":"ja","x_late":"このSmart Componentには、HPE 6Gb SAS BLスイッチのファームウェアイメージが含まれています。コンポーネントをダウンロードしてディレクトリにファームウェアイメージを展開したら、Virtual SAS ManagerのGUIかCLIインターフェイスにアクセスしてファームウェアをフラッシュします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online HP 6Gb SAS BL Switch Firmware Smart Component for Windows&nbsp;(x86/x64)<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;4.3.6.0 (C)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 4.3.6.0 (B)<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 4.2.1.0<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; The devices listed below require minimum FW deliverables with HP Storage Manager version 4.1.1.0:<br />\n<br />\n<strong>Device, Minimum Recommended Version</strong></p>\n\n<ul>\n\t<li>HP D3600/D3700/D3610/D3710 Disk Enclosure, 3.64</li>\n\t<li>HP D2600/D2700 Disk Enclosure, 0150</li>\n\t<li>HP 600 Modular Disk System, 3.68</li>\n\t<li>HP D6000 Disk Enclosure, 2.98</li>\n\t<li>HP D6020 Disk Enclosure, 2.53</li>\n</ul>\n\n<p><strong>Enhancements/New Features for FW version 4.3.6.0 (C):</strong>&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<ul>\n\t<li>Improved integration with Smart Update Manager</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp; &nbsp;</strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"34248016","datemodified":"2018-11-27T03:29:38","file_list":["cp038273.xml","cp_data.xml","Entry.bsh","vsm_release_4.3.6.0.img"],"md5sum":"dd34c209e5f44e8294c17058ac55a93a","name":"cp038273.exe","release":"2018-11-27T09:28:04","revision":"0","sha1sum":"a28dcfb93408d6ad568751c732f5dc51abb55f76","size":"32MB","target_guids":[],"type_of_change":"0","version":"4.3.6.0"}],"id":{"product":"3ed50c140ece462d9878c300a512c4f5","version":"2b418b1cf2454e5d9af13cfa6c71ef45"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Installation Instructions:</strong></p>\n\n<p><strong>To update firmware from&nbsp;Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.&nbsp;</li>\n\t<li>Double-click on the Smart Component.&nbsp;</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>HP recommends for remote deployment of this package that you obtain the most recent version of the </strong><a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant</u>&nbsp;</a><strong>&nbsp;(SPP) and follow these steps:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the firmware to be updated in the directory, \\SPP20xxxxx\\packages on the USB key.</li>\n\t<li>Run launch_sum.bat script which is found in the root of the ISO</li>\n\t<li>Follow the GUI instructions to install the firmware on the remote host.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>インストール手順：</strong></p>\n\n<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントをテンポラリディレクトリに置きます。 </li>\n\t<li>Smartコンポーネントをダブルクリックします。 </li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n</ul>\n\n<p><strong>このパッケージのリモートデプロイメントには、最新のバージョンの</strong><a href=\"http://www.hpe.com/info/spp\">HP Service Pack for ProLiant</a><u>（SPP）を入手して、以下の手順を実行することをおすすめします。</u></p>\n\n<ul>\n\t<li><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant</u></a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの\\SPP20xxxxx\\packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにあるlaunch_hpsum.batスクリプトを実行します。</li>\n\t<li>GUIの指示に従ってリモートホストにファームウェアをインストールします。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HPE 6Gb SAS BL Switch Firmware Smart Component for Windows (x86/x64)"},{"lang":"ja","x_late":"オンラインHPE 6 Gb SAS BLスイッチファームウェアSmart Component for Windows (x86/x64)"}],"prerequisites":{"required_diskspace":{"size_kb":"10"},"supported_devices":[{"id":"HP6GSASBLSWH","target_guid":"","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-12-27T09:14:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for&nbsp;Microsoft Windows Server 2019 OS</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>\n\t<p style=\"margin-left:0in; margin-right:0in\">Improved integration with Smart Update Manager</p>\n\t</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"solex","sw_key_expectedpath":"firmware:solex6Gb"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300027","languages":[{"lang":"tw","x_late":"驅動程式 ─ 系統"},{"lang":"en","x_late":"Driver - System"},{"lang":"ko","x_late":"드라이버 - 시스템"},{"lang":"ja","x_late":"ドライバ - システム"},{"lang":"cn","x_late":"驱动程序 - 系统"}]}],"description":[{"lang":"en","x_late":"This component provides drivers for HPE NVDIMM-N devices and HPE Persistent Memory devices (featuring Intel Optane DC Persistent Memory) installed on systems running Microsoft Windows Server 2012 R2 and 2016."},{"lang":"ja","x_late":"このコンポーネントは、Microsoft Windows Server 2012 R2および2016を実行しているシステムにインストールされているHPE NVDIMM-NデバイスおよびHPE Persistent Memoryデバイス(Intel Optane DC Persistent Memoryを搭載)のドライバを提供します。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"1015488","datemodified":"2021-02-01T03:15:23","file_list":["cp042922.xml","cpqsetup.exe","hpenvmbus.cat","HpeNvmBus.inf","HpeNvmBus.pdb","HpeNVMBus.sys","HpeNvmBusApi.h","HpeNVMdisk0101.cat","HpeNvmDisk0101.inf","HpeNvmDisk0101.pdb","Hpenvmdisk0101.sys","HpeNvmDsm.h","HpeNvmInstaller.dll","install.xml"],"md5sum":"1b049bf417c034de5f8b35820763448a","name":"cp042922.exe","release":"2021-02-01T03:13:04","revision":"0","sha1sum":"c151b679488b242f311d0255098eb0666d808ba1","size":"0MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ece0b66b06"],"type_of_change":"1","version":"3.0.2.0"}],"id":{"product":"45e734b674094fd09fe52836988b3440","version":"af8ed8c436a9407b83b20b9744f055d5"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Steps to install this Smart Component:</p>\n\n<ul>\n\t<li>If a previous version is already installed, it is recommended to first stop all use of the Persistent Memory devices and disks, and uninstall&nbsp;it from the Control Panel, Uninstall a Program.</li>\n\t<li>Download the Smart Component to a directory on your hard drive and change to that directory.</li>\n\t<li>From that drive and directory, execute the downloaded file.</li>\n\t<li>Click the Install button to proceed with the installation.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>このSmartコンポーネントをインストールする手順：</p>\n\n<ul>\n\t<li>以前のバージョンがすでにインストールされている場合は、最初にPersistent Memoryデバイスとディスクの使用をすべて停止し、[コントロールパネル]の[プログラムのアンインストール]からアンインストールすることをお勧めします。</li>\n\t<li>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。</li>\n\t<li>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</li>\n\t<li>[インストール]ボタンをクリックして、インストールを開始してください。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Non-Volatile Memory Drivers for Microsoft Windows Server 2012 R2 and 2016"},{"lang":"ja","x_late":"HPE 不揮発性メモリドライバーfor Microsoft Windows Server 2012 R2および2016"}],"prerequisites":{"required_diskspace":{"size_kb":"4096"},"supported_devices":[{"id":"ACPI\\VEN_ACPI&DEV_0012","target_guid":"","type":"pnp"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-02-15T01:56:16","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>These Non-Volatile Memory&nbsp;drivers enable support for Persistent Memory technology on select HPE Servers running Microsoft Windows Server 2012 R2 and 2016.</p>\n\n<ul>\n\t<li>Added support for HPE Persistent Memory devices (featuring Intel Optane DC Persistent Memory), on WS2012R2 and WS2016.</li>\n\t<li>Added support for HPE 16GB NVDIMM devices, on WS2012R2.</li>\n\t<li>Changed block sector size from 512B to 4096B. Old data won&#39;t be accessible and must be backed up first if it needs to be preserved.</li>\n</ul>\n\n<p>For more information about Persistent Memory technology offered on HPE Servers, please consult the following links:</p>\n\n<ul>\n\t<li><a href=\"https://www.hpe.com/us/en/servers/persistent-memory.html\">https://www.hpe.com/us/en/servers/persistent-memory.html</a></li>\n\t<li><a href=\"https://persistentmemory.hpe.com/windows/nvdimm\">https://persistentmemory.hpe.com/windows/nvdimm</a></li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>These Non-Volatile Memory&nbsp;drivers enable support for Persistent Memory technology on select HPE Servers running Microsoft Windows Server 2012 R2 and 2016.</p>\n\n<ul>\n\t<li>Added support for Microsoft virtual NVDIMMs (aka vNVDIMMs) presented by Hyper-V Server 2019, on WS2012R2 and WS2016 guests.</li>\n\t<li>Added support for HPE Persistent Memory devices (featuring Intel Optane DC Persistent Memory), on WS2012R2 and WS2016.</li>\n\t<li>Added support for HPE 16GB NVDIMM devices, on WS2012R2.</li>\n\t<li>Changed block sector size from 512B to 4096B. Old data won&#39;t be accessible and must be backed up first if it needs to be preserved.</li>\n</ul>\n\n<p>For more information about Persistent Memory technology offered on HPE Servers, please consult the following links:</p>\n\n<ul>\n\t<li><a href=\"https://www.hpe.com/us/en/servers/persistent-memory.html\">https://www.hpe.com/us/en/servers/persistent-memory.html</a></li>\n\t<li><a href=\"https://persistentmemory.hpe.com/windows/nvdimm\">https://persistentmemory.hpe.com/windows/nvdimm</a></li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"HpeNvmInstaller.dll","sw_key_expectedpath":"%systemdrive%\\cpqsystem\\pnpdrvs"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the SRIOV virtual function drivers for the HPE Intel i40e Ethernet NICs running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 8で動作するHPE Intel i40e Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"95181","datemodified":"2021-08-24T16:51:29","file_list":["./etc/depmod.d/hp-iavf.conf","./etc/dracut.conf.d/hp-iavf-oob.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/hp-iavf","./lib/modules/4.18.0-240.el8.x86_64/extra/hp-iavf/iavf.ko","./usr/lib/.build-id","./usr/lib/.build-id/ec","./usr/lib/.build-id/ec/395064640281498bce40c7c8067c43efcd6123","./usr/share/smartupdate/kmod-hp-iavf/component.xml"],"md5sum":"c07778b5c6c8c4cdb9cd0a25953419cd","name":"kmod-hp-iavf-4.2.7-1.rhel8u3.x86_64.rpm","release":"2021-08-24T16:35:05","revision":"0","sha1sum":"a6a4ff63aa102daabbabb04406fdcf7db7d1fa69","size":"92KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec0e19bfd1"],"type_of_change":"0","version":"4.2.7-1"},{"bytes":"95310","datemodified":"2021-08-24T16:45:44","file_list":["./etc/depmod.d/hp-iavf.conf","./etc/dracut.conf.d/hp-iavf-oob.conf","./lib/modules/4.18.0-305.el8.x86_64","./lib/modules/4.18.0-305.el8.x86_64/extra","./lib/modules/4.18.0-305.el8.x86_64/extra/hp-iavf","./lib/modules/4.18.0-305.el8.x86_64/extra/hp-iavf/iavf.ko","./usr/lib/.build-id","./usr/lib/.build-id/82","./usr/lib/.build-id/82/56fef0f45c9581aa85257f22034eda8a842a0e","./usr/share/smartupdate/kmod-hp-iavf/component.xml"],"md5sum":"f3260a4c5ef383271f2c20adbc51422e","name":"kmod-hp-iavf-4.2.7-1.rhel8u4.x86_64.rpm","release":"2021-08-24T16:35:05","revision":"0","sha1sum":"276dd88a8780eefb3243fb6d86b576fe82f077d2","size":"93KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec0e19bfd1"],"type_of_change":"0","version":"4.2.7-1"}],"id":{"product":"26d6bb7ca1354a5998790d5fa42f5aa8","version":"37907d27ee8e41a9ae26eb5f564dcf81"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Intel iavf Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE Intel iavf ドライバー for Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"1592","subdev":"0002","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159280860002","type":"pci","ven":"8086"},{"dev":"1592","subdev":"0006","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159280860006","type":"pci","ven":"8086"},{"dev":"159B","subdev":"0003","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159b80860003","type":"pci","ven":"8086"},{"dev":"159B","subdev":"0005","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159b80860005","type":"pci","ven":"8086"},{"dev":"1593","subdev":"0005","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159380860005","type":"pci","ven":"8086"},{"dev":"1592","subdev":"000E","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-15928086000e","type":"pci","ven":"8086"},{"dev":"1593","subdev":"000C","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-15938086000c","type":"pci","ven":"8086"},{"dev":"1581","subdev":"00F8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1581159000f8","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>&nbsp;</p>\n\n<ul>\n\t<li>This product now supports Red Hat Enterprise Linux 8 update 2 and Red Hat Enterprise Linux 8 update 3</li>\n\t<li>This product now supports the following servers:</li>\n</ul>\n\n<p style=\"margin-left:80px\">&nbsp;HPE Superdome Flex 280 &nbsp;<br />\n&nbsp;HPE Superdome Flex Server &nbsp;<br />\n&nbsp;HPE Superdome Flex 2&nbsp;</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 8 update 4</p>\n","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where HyperV Ping is lost after change MTU on VF interface in a VM linux</li>\n\t<li>This product addresses an issue which could lead to traffic interrupts and full traffic stop through the bond when VFs were added to bonding-alb/tlb modes</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-hp-iavf","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-iavf","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-iavf","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-iavf","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for HPE Blade QLogic NX2 10/20 GbE Multifunction Adapters running under VMware vSphere 6.5."},{"lang":"ja","x_late":"この製品には、VMware vSphere 6.5上で動作するHPE Blade QLogic NX2 10/20 GbEマルチファンクションアダプター用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains the following drivers:</p>\n\n<ul>\n\t<li>qcnic, version 1.0.59.0</li>\n\t<li>qfle3i, version 1.1.5.0</li>\n\t<li>qfle3f, version 1.1.25.0</li>\n\t<li>qfle3, version 1.1.17.0</li>\n</ul>\n"}],"files":[{"bytes":"1399141","datemodified":"2021-08-12T04:40:50","file_list":["/cp047831.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/metadata.zip","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/vib20/qfle3i/QLC_bootbank_qfle3i_1.1.5.0-1OEM.650.0.0.4598673.vib","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/vib20/qfle3f/QLC_bootbank_qfle3f_1.1.25.0-1OEM.650.0.0.4598673.vib","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/vib20/qcnic/QLC_bootbank_qcnic_1.0.59.0-1OEM.650.0.0.4598673.vib","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/vib20/qfle3/QLC_bootbank_qfle3_1.1.17.0-1OEM.650.0.0.4598673.vib","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/metadata.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/metadata.zip/vmware.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/metadata.zip/vibs/qcnic-478720060.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/metadata.zip/vibs/qfle3f-1875916866.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/metadata.zip/vibs/qfle3i--1959034772.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/metadata.zip/vibs/qfle3-876788810.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-qfle3-1.1.17.0.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-qcnic-1.0.59.0.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-qfle3f-1.1.25.0.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-qfle3i-1.1.5.0.xml"],"md5sum":"570b64407a76faf148c8869a1fedc204","name":"cp047831.zip","release":"2021-08-12T04:37:35","revision":"0","sha1sum":"f1ae6ad5da339ecb7fbcc6791eccff31d7dafe5a","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","20a6e8e4-bf33-4c71-a6bf-d9ecbba24fc7","20a6e8e4-bf33-4c71-a6bf-d9ec7339bbbe","20a6e8e4-bf33-4c71-a6bf-d9eca261a1a0"],"type_of_change":"0","version":"2021.09.01","vib_list":[{"name":"qfle3","version":"1.1.17.0-1OEM.650.0.0.4598673"},{"name":"qcnic","version":"1.0.59.0-1OEM.650.0.0.4598673"},{"name":"qfle3f","version":"1.1.25.0-1OEM.650.0.0.4598673"},{"name":"qfle3i","version":"1.1.5.0-1OEM.650.0.0.4598673"}]}],"id":{"product":"e3347115cdc54c64abafd1793b901484","version":"a90e9c15f47c4ed9a0eb1ac36f1a548f"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for VMware vSphere 6.5"},{"lang":"ja","x_late":"HPE Blade QLogic NX2 10/20 GbEマルチファンクションドライバー for VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"168E","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1933","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c22fa","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1917","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1916","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1933","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1916","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1917","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c22fa","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1933","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c22fa","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1916","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1917","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-03T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports VMware vSphere 6.5 U3.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product enhances PLOGI for the HPE XP7 Storage Array.</p>\n","curr_fixes_x_late":"<p>This product addresses a PSOD seen during device state changes without IDLE state.<br />\nThis product addresses a PSOD seen during scheduling fabic login.<br />\nThis product addresses a PSOD issue to enhance immediately flush in work queue and unload/quiesce mechanisms.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"qfle3:1.1.17.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qcnic:1.0.59.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qfle3i:1.1.5.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qfle3f:1.1.25.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel and Mezzanine Host Bus Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"586294","datemodified":"2021-08-26T08:47:13","file_list":["./lib/modules/5.3.18-57-default","./lib/modules/5.3.18-57-default/updates","./lib/modules/5.3.18-57-default/updates/lpfc.ko","./usr/share/smartupdate/elx-lpfc-kmp-default/component.xml"],"md5sum":"a8cf886ee1c462728a94cf7058b298c7","name":"elx-lpfc-kmp-default-12.8.528.7_k5.3.18_57-1.sles15sp3.x86_64.rpm","release":"2021-08-26T08:39:04","revision":"0","sha1sum":"2b0e3bae89a7551b7e2385498dbe267f1d738b84","size":"572KB","target_guids":[],"type_of_change":"1","version":"12.8.528.7"}],"id":{"product":"d714903907fa40a895d2daac129ea220","version":"869526830cf14d5280982322d8d9db0c"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh elx-lpfc-kmp-default-12.8.509.3_k5.3.18_51-1.sles15sp3.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>\n\n<p>Rewrite of same Driver version has to be performed using &ndash;reinstall option</p>\n\n<p>Example: rpm &ndash;Uvh elx-lpfc-kmp-default-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm &ndash;reinstall</p>\n\n<p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"SUSE Linux Enterprise Server 15 Service Pack 3 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters and Mezzanine Host Bus Adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"F100","subven":"10DF","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T10:36:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added the following support:</p>\n\n<ul>\n\t<li>Added support for S:ES 15 SP3</li>\n</ul>\n\n<p>Updated to driver version 12.8.528.7</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"elx-lpfc-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for HPE Blade QLogic NX2 10/20 GbE Multifunction Adapters running under VMware vSphere 7.0."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains the following drivers in bundle MRVL-E3-Ethernet-iSCSI-FCoE:3.0.143.0-1OEM.700.1.0.15843807:</p>\n\n<ul>\n\t<li>qcnic, version 2.0.59.0</li>\n\t<li>qfle3, version 1.4.17.0</li>\n\t<li>qfle3f, version 2.1.25.0</li>\n\t<li>qfle3i, version 2.1.8.0</li>\n</ul>\n"}],"files":[{"bytes":"1513197","datemodified":"2021-08-12T04:41:49","file_list":["/cp047630.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip/index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip/metadata.zip","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip/vib20/qcnic/QLC_bootbank_qcnic_2.0.59.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip/vib20/qfle3i/QLC_bootbank_qfle3i_2.1.8.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip/vib20/qfle3f/QLC_bootbank_qfle3f_2.1.25.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip/vib20/qfle3/QLC_bootbank_qfle3_1.4.17.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip/metadata.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip/metadata.zip/vmware.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip/metadata.zip/vibs/qfle3-1191248098602857359.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip/metadata.zip/vibs/qfle3i--558247773911429780.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip/metadata.zip/vibs/qfle3f--371781071515599867.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip/metadata.zip/vibs/qcnic-3768180827600800407.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip/metadata.zip/bulletins/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807.xml"],"md5sum":"00fc0c3c5f98ce773bed9522e3497ed4","name":"cp047630.zip","release":"2021-08-12T04:38:34","revision":"0","sha1sum":"bbff508c1ebdea1ca83509981dcaa12e4eb7d06f","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eca261a1a0","20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","20a6e8e4-bf33-4c71-a6bf-d9ec7339bbbe","20a6e8e4-bf33-4c71-a6bf-d9ece189dca8","20a6e8e4-bf33-4c71-a6bf-d9ecbba24fc7"],"type_of_change":"0","version":"2021.09.01","vib_list":[{"name":"qcnic","version":"2.0.59.0-1OEM.700.1.0.15843807"},{"name":"qfle3i","version":"2.1.8.0-1OEM.700.1.0.15843807"},{"name":"qfle3f","version":"2.1.25.0-1OEM.700.1.0.15843807"},{"name":"qfle3","version":"1.4.17.0-1OEM.700.1.0.15843807"}]}],"id":{"product":"d2fcdefd57524f44b8d7ad99311fad8f","version":"da957069bc3740f69c87aa777f86386c"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバーにUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"168E","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1933","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c22fa","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1917","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1916","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1933","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1916","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1917","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c22fa","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1933","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c22fa","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1916","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1917","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-03T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports VMware vSphere 7.0 U1.</p>\n","latest_fixes_x_late":"<p>This product addresses a PSOD involving an encapsulated header.<br />\nThis product addresses a PSOD seen during traffic scheduling.<br />\nThis product corrects an incorrect MTU value displayed by the ESXCLI tool.<br />\nThis product addresses a PSOD issue seen during Storage vMotion operation.<br />\nThis product addresses PSODs seen during discovery timeout, transmit scheduling, and LUN reset scenarios.<br />\nThis product addresses a PSOD seen on systems operating in a complicated VLAN environment.<br />\nThis product addresses a PSOD seen during critical packet drop scenarios.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports VMware ESXi 7.0 U3.<br />\nThis product enhances PLOGI for the HPE XP7 Storage Array.</p>\n","curr_fixes_x_late":"<p>This product addresses a PSOD seen while collecting data dump.<br />\nThis product addessses a PSOD seen during uplink reset with failure conditions.<br />\nThis product addresses a PSOD seen during device state changes without IDLE state.<br />\nThis product addresses a PSOD seen during scheduling fabic login.<br />\nThis product addresses a PSOD issue to enhance immediately flush in work queue and unload/quiesce mechanisms.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"qfle3f:2.1.25.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qfle3:1.4.17.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qfle3i:2.1.8.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"MRVL-E3-Ethernet-iSCSI-FCoE:3.0.143.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver.component:vmware:zip"},{"name":"qcnic:2.0.59.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800095","languages":[{"lang":"fr","x_late":"Logiciel - Réseau"},{"lang":"en","x_late":"Software - Network"},{"lang":"cn","x_late":"软件 - 网络"},{"lang":"tw","x_late":"軟體 ─ 網路"},{"lang":"de","x_late":"Software - Netzwerk"},{"lang":"ko","x_late":"소프트웨어 - 네트워크"},{"lang":"it","x_late":"Software - Rete"},{"lang":"ja","x_late":"ソフトウェア - ネットワーク"},{"lang":"es","x_late":"Software - Red"}]}],"description":[{"lang":"tw","x_late":"此代理程式會從執行 Linux x86_64 平台的 HPE 伺服器內受支援的 Broadcom 網路配接卡擷取感測器與健康狀況資料。"},{"lang":"en","x_late":"This agent extracts sensor and health data from supported Broadcom network adapters in HPE servers running Linux x86_64 platforms."},{"lang":"ko","x_late":"이 에이전트는 Linux x86_64 플랫폼이 탑재된 HPE 서버에서 지원 가능한 Broadcom 네트워크 어댑터를 통해 센서 및 상태 데이터를 추출합니다."},{"lang":"cn","x_late":"该代理可在运行 Linux x86_64 平台的 HPE 服务器中从支持的 Broadcom 网络适配器解压传感器和状态数据。"},{"lang":"ja","x_late":"このエージェントは、Linux x86_64プラットフォームを実行しているHPEサーバーでサポートされているBroadcomネットワークアダプターから、センサーおよびヘルスのデータを抽出します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"22582","datemodified":"2018-10-17T21:13:35","file_list":["./etc/init.d/tg3sd","./usr/sbin/tg3sd","./usr/share/smartupdate/hp-tg3sd/component.xml"],"md5sum":"f3cb58e5e6ed18e996779ca82fd9d0f5","name":"hp-tg3sd-1.0.21-1.x86_64.rpm","release":"2018-10-17T21:13:06","revision":"0","sha1sum":"e9b006a325a6ae02b7aa54a5e69e22cb8fb63347","size":"22KB","target_guids":[],"type_of_change":"0","version":"1.0.21-1"}],"id":{"product":"9927526d75db4a7cba662ab57f85142d","version":"ab99ef45554b4bb39a66f33a98247a6b"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download hp-tg3sd-1.0.21-1.x86_64.txt to view installation instructions.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 HPE ProLiant 網路配接卡的 Broadcom Active Health System 代理程式 (用於 Linux x86_64)"},{"lang":"en","x_late":"Broadcom Active Health System Agent for HPE ProLiant Network Adapters for Linux x86_64"},{"lang":"ko","x_late":"HPE 프로라이언트 네트워크 어댑터용 Broadcom Active Health System Agent(Linux x86_64)"},{"lang":"cn","x_late":"适用于采用 Linux x86_64 的 HPE ProLiant 网络适配器的 Broadcom Active Health System 代理"},{"lang":"ja","x_late":"HPE ProLiantネットワークアダプター for Linux x86_64用Broadcom Active Health Systemエージェント"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"165F","subdev":"22E8","subven":"103C","target_guid":"","type":"pci","ven":"14E4"},{"dev":"1665","subdev":"22BD","subven":"103C","target_guid":"","type":"pci","ven":"14E4"},{"dev":"165F","subdev":"1786","subven":"103C","target_guid":"","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"169D","subven":"103C","target_guid":"","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"3383","subven":"103C","target_guid":"","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"22BE","subven":"103C","target_guid":"","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2018-11-05T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>SUM no longer attempts to install this product on Gen10 servers, which this product&nbsp;does not support.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product adddresses a library dependency issue seen when installing&nbsp;on a system running SUSE Linux Enterprise Server 15.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"hp-tg3sd","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960RWUEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALSHPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554556","Version":"HPD6"},{"DeviceName":"VO001920RWUFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALSHPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554641","Version":"HPD6"},{"DeviceName":"VO003840RWUFB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALSHPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554642","Version":"HPD6"},{"DeviceName":"VO007680RWUFC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALSHPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-305257554643","Version":"HPD6"},{"DeviceName":"VO000960RWUFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALSHPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554644","Version":"HPD6"},{"DeviceName":"VO001920RWUFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALSHPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554645","Version":"HPD6"},{"DeviceName":"VO003840RWUFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALSHPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554646","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF"},{"lang":"ja","x_late":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO000960RWUEV、VO001920RWUFA、VO003840RWUFB、VO007680RWUFC、VO000960RWUFD、VO001920RWUFE およびVO003840RWUFF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>TBD</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5324194","datemodified":"2021-08-26T07:12:16","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD6-1.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD6-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD6-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD6-1.1/CP049364.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD6-1.1/TARM5ALSHPD6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD6-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD6-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD6-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD6-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049364.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049364.scexe"],"md5sum":"8614365b35d30c90beb5a3a9de65d1cb","name":"firmware-hdd-8fafc9efb2-HPD6-1.1.x86_64.rpm","release":"2021-08-26T07:00:08","revision":"0","sha1sum":"7522d3ebae44b83e9f1c07ff77f3db6319ec7ce4","size":"5MB","target_guids":["562340a5-304f-3030-3936-305257554556","562340a5-304f-3130-3932-305257554641","562340a5-304f-3330-3834-305257554642","562340a5-304f-3730-3638-305257554643","562340a5-304f-3030-3936-305257554644","562340a5-304f-3130-3932-305257554645","562340a5-304f-3330-3834-305257554646"],"type_of_change":"1","version":"HPD6"}],"id":{"product":"9fd1abd8973f4c09aa450e541dc4ee41","version":"079a21793d7a4c4e95b1ac9602bbf164"},"installation":{"command":"CP041555.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) -  VO000960RWUEV、VO001920RWUFA、VO003840RWUFB、VO007680RWUFC、VO000960RWUFD、VO001920RWUFE およびVO003840RWUFFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VO007680RWUFC","target_guid":"562340a5-304f-3730-3638-305257554643","type":"sas"},{"id":"VO003840RWUFF","target_guid":"562340a5-304f-3330-3834-305257554646","type":"sas"},{"id":"VO003840RWUFB","target_guid":"562340a5-304f-3330-3834-305257554642","type":"sas"},{"id":"VO001920RWUFE","target_guid":"562340a5-304f-3130-3932-305257554645","type":"sas"},{"id":"VO001920RWUFA","target_guid":"562340a5-304f-3130-3932-305257554641","type":"sas"},{"id":"VO000960RWUFD","target_guid":"562340a5-304f-3030-3936-305257554644","type":"sas"},{"id":"VO000960RWUEV","target_guid":"562340a5-304f-3030-3936-305257554556","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-26T06:55:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Change Vendor Identification Field (VID data) from &quot;HP&quot; to &quot;HPE&quot;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>TBD</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO000960RWUFD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO007680RWUFC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000960RWUEV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003840RWUFB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003840RWUFF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920RWUFA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920RWUFE","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWJAN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-3047574a414e","Version":"HPG1"},{"DeviceName":"MB002000GWFWA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757465741","Version":"HPG1"},{"DeviceName":"MB004000GWFWB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757465742","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB001000GWJAN, MB002000GWFWA and MB004000GWFWB Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB001000GWJAN、MB002000GWFWA および MB004000GWFWB ドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"16951781","datemodified":"2021-08-30T19:01:51","file_list":["/CP048313_BUILD_3.data","/CP048313.vmexe","/CP048313.vmexe64","/CP048313.vmfile","/CP048313_VMw.zip","/CP048313.xml","/payload.json","/CP048313_VMw.zip/index.xml","/CP048313_VMw.zip/vendor-index.xml","/CP048313_VMw.zip/metadata.zip","/CP048313_VMw.zip/vib20/CP048313/HPE_bootbank_CP048313_HPG1.3-7.0.0.15843807.vib","/CP048313_VMw.zip/metadata.zip/vendor-index.xml","/CP048313_VMw.zip/metadata.zip/vmware.xml","/CP048313_VMw.zip/metadata.zip/vibs/CP048313--3087150825584867912.xml","/CP048313_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048313_HPG1.3-7.0.0.15843807.xml"],"md5sum":"73c08e34413d771ebfc190c1d2f53d56","name":"CP048313.zip","release":"2021-08-30T18:56:52","revision":"0","sha1sum":"b12b7f34bc0e6554134ea1bf4696a7e3407fd80e","size":"16MB","target_guids":["4d2340a5-3042-3130-3030-3047574a414e","4d2340a5-3042-3230-3030-304757465741","4d2340a5-3042-3430-3030-304757465742"],"type_of_change":"1","version":"HPG1","vib_list":[{"name":"CP048313","version":"HPG1.3-7.0.0.15843807"}]}],"id":{"product":"0f2b8614c6ab40aea6c15cd633ff1402","version":"c264bb9434d44d469246a2527f3bdf82"},"installation":{"command":"CP040691.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB  Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor ESXi - MB001000GWJAN、MB002000GWFWAおよびMB004000GWFWBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB004000GWFWB","target_guid":"4d2340a5-3042-3430-3030-304757465742","type":"sata"},{"id":"MB002000GWFWA","target_guid":"4d2340a5-3042-3230-3030-304757465741","type":"sata"},{"id":"MB001000GWJAN","target_guid":"4d2340a5-3042-3130-3030-3047574a414e","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-04T05:32:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB004000GWFWB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB001000GWJAN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB002000GWFWA","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"本產品包含 SUSE Linux Enterprise Server 12 x86_64 下執行的 HPE Intel i40e 乙太網路 NIC 之 SRIOV 虛擬功能驅動程式。"},{"lang":"en","x_late":"This product contains the SRIOV virtual function drivers for the HPE Intel i40e Ethernet NICs running under SUSE Linux Enterprise Server 12 x86_64."},{"lang":"ko","x_late":"이 제품에는 SUSE Linux Enterprise Server 12 x86_64에서 실행되는 HPE Intel i40e 이더넷 NIC용 SRIOV 가상 기능 드라이버가 포함되어 있습니다."},{"lang":"cn","x_late":"本产品包含适用于在SUSE Linux Enterprise Server 12 x86_64下运行的HPE Intel i40e以太网网卡SRIOV虚拟功能驱动程序。"},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12 x86_64で動作するHPE Intel i40e Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1541916","datemodified":"2021-08-24T17:13:18","file_list":["./etc/depmod.d/hp-iavf.conf","./etc/dracut.conf.d/hp-iavf-oob.conf","./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/hp-iavf","./lib/modules/4.12.14-120-default/updates/hp-iavf/iavf.ko","./usr/share/smartupdate/hp-iavf-kmp-default/component.xml"],"md5sum":"38c57191d49b37b0bf32e93aa45eae69","name":"hp-iavf-kmp-default-4.2.7_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-08-24T17:05:06","revision":"0","sha1sum":"b2e97f1f4e162476f079675a18cee6aafb210212","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec8201731a"],"type_of_change":"0","version":"4.2.7-1"}],"id":{"product":"e05dec268daa4148be358b19a3214eed","version":"8967d5dabe0e420cadc4b87bffd0d992"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Intel iavf Drivers for SUSE Linux Enterprise Server 12 x86_64"},{"lang":"ja","x_late":"HPE Intel iavfドライバー for SUSE Linux Enterprise Server 12 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"1592","subdev":"0002","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159280860002","type":"pci","ven":"8086"},{"dev":"1592","subdev":"0006","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159280860006","type":"pci","ven":"8086"},{"dev":"159B","subdev":"0003","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159b80860003","type":"pci","ven":"8086"},{"dev":"159B","subdev":"0005","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159b80860005","type":"pci","ven":"8086"},{"dev":"1593","subdev":"0005","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159380860005","type":"pci","ven":"8086"},{"dev":"1592","subdev":"000E","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-15928086000e","type":"pci","ven":"8086"},{"dev":"1593","subdev":"000C","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-15938086000c","type":"pci","ven":"8086"},{"dev":"1581","subdev":"00F8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1581159000f8","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul style=\"list-style-type:square\">\n\t<li>This product now supports the following servers:</li>\n</ul>\n\n<p style=\"margin-left:80px; margin-right:0px; text-align:left\">&nbsp;HPE Superdome Flex 280 &nbsp;<br />\n&nbsp;HPE Superdome Flex Server &nbsp;<br />\n&nbsp;HPE Superdome Flex 2&nbsp;</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where HyperV Ping is lost after change MTU on VF interface in a VM linux</li>\n\t<li>This product addresses an issue which could lead to traffic interrupts and full traffic stop through the bond when VFs were added to bonding-alb/tlb modes</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"hp-iavf-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWWQB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a57575142","Version":"HPD6"},{"DeviceName":"MB002000JWWQA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a57575141","Version":"HPD6"},{"DeviceName":"MB001000JWWPV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304a57575056","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB004000JWWQB, MB002000JWWQA and MB001000JWWPV"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB004000JWWQB、MB002000JWWQA、およびMB001000JWWPV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MB004000JWWQB, MB002000JWWQA and MB001000JWWPV Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD4</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"3947472","datemodified":"2021-07-25T20:53:18","file_list":["cp048653.xml","cpqsetup.exe","payload.json","SCIMARRNNSD6.rel","setup.dll"],"md5sum":"cfa1e1f12d58dc18a940b79be82cc193","name":"cp048653.exe","release":"2021-07-25T20:46:07","revision":"0","sha1sum":"f9d481bd6ce962107c7d96a05cd242a3a60f2c1d","size":"3MB","target_guids":["4d2340a5-3042-3430-3030-304a57575142","4d2340a5-3042-3230-3030-304a57575141","4d2340a5-3042-3130-3030-304a57575056"],"type_of_change":"1","version":"HPD6"}],"id":{"product":"eb650e36c9b84eb1b7c6c75d7ff3e9f2","version":"4031b272f4a0478a98c57758723116b8"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB004000JWWQB, MB002000JWWQA and MB001000JWWPV Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for Windows (x64) - MB004000JWWQB、MB002000JWWQA、およびMB001000JWWPVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB004000JWWQB","target_guid":"4d2340a5-3042-3430-3030-304a57575142","type":"sas"},{"id":"MB002000JWWQA","target_guid":"4d2340a5-3042-3230-3030-304a57575141","type":"sas"},{"id":"MB001000JWWPV","target_guid":"4d2340a5-3042-3130-3030-304a57575056","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T19:01:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB002000JWWQA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB001000JWWPV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB004000JWWQB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900217","languages":[{"lang":"fr","x_late":"Micrologiciel - Infrastructure Blade"},{"lang":"en","x_late":"Firmware - Blade Infrastructure"},{"lang":"cn","x_late":"固件 - 刀片式架构"},{"lang":"tw","x_late":"韌體 ─ 刀鋒型基礎架構"},{"lang":"de","x_late":"Firmware - Blade-Infrastruktur"},{"lang":"ko","x_late":"펌웨어 - 블레이드 인프라"},{"lang":"it","x_late":"Firmware - Infrastruttura Blade"},{"lang":"ja","x_late":"ファームウェア - ブレード インフラストラクチャ"},{"lang":"es","x_late":"Firmware - Infraestructura Blade"}]}],"description":[{"lang":"tw","x_late":"此元件包含 HPE BladeSystem c-Class Onboard Administrator 的韌體映像。此韌體提供 HPE BladeSystem c-Class Enclosure 的管理功能。此元件及其韌體可用於下列情況： 1) 作為可以為 Onboard Administrator 韌體的部署而編寫指令碼的獨立元件，2) 在和可以在 Smart Update 韌體 DVD 上找到的 HP Smart Update Manager 一起使用時，此元件可以用於部署韌體至 HP BladeSystem c-Class Onboard Administrator，以及 3) 從該元件解壓縮的韌體可使用 HP BladeSystem c-Class Onboard Administrator 的網路型使用者介面來部署。"},{"lang":"en","x_late":"This component contains the firmware image for HPE BladeSystem c-Class Onboard Administrator. This firmware provides management capabilities for the HPE BladeSystem c-Class Enclosure. This component and its firmware can be used in the following scenarios: 1) as a stand alone component that can be used to script the deployment of the Onboard Administrator firmware, 2) in conjunction with the HPE Smart Update Manager found on the Smart Update Firmware DVD, the component can be used to deploy the firmware to the HPE BladeSystem c-Class Onboard Administrator, and 3) firmware extracted from the component can be deployed using the web-based user interface for the HPE BladeSystem c-Class Onboard Administrator."},{"lang":"ko","x_late":"이 구성 요소에는 HPE BladeSystem c-Class Onboard Administrator의 펌웨어 이미지가 포함되어 있습니다. 이 펌웨어는 HPE BladeSystem c-Class Enclosure에 대한 관리 기능을 제공합니다. 해당 구성요소와 펌웨어는 다음과 같은 상황에서 사용할 수 있습니다. 1) 독립형 구성 요소로서 Onboard Administrator 펌웨어의 배포 스크립트에 사용될 수 있습니다 2) 스마트 업데이트 펌웨어 DVD에 포함되어 있는 HP Smart Update Manager와 함께 구성요소를 사용하여 HP BladeSystem c-Class Onboard Administrator로 펌웨어를 배포할 수 있습니다 3) HP BladeSystem c-Class Onboard Administrator용 웹 기반 사용자 인터페이스를 사용하여 구성 요소에서 추출된 펌웨어를 배포할 수 있습니다."},{"lang":"cn","x_late":"该组件包含适用于 HPE BladeSystem c-Class Onboard Administrator 的固件映像。该固件可为 HPE BladeSystem c-Class 机箱提供管理功能。该组件及其固件适用于以下情形： 1) 作为可用于编写 Onboard Administrator 固件的部署脚本的独立组件，2) 与 HPE Smart Update Firmware DVD 中的 HP Smart Update Manager 共同使用，此组件可用于将固件部署至 HPE BladeSystem c-Class Onboard Administrator，以及 3) 可使用 HPE BladeSystem c-Class Onboard Administrator 的基于 WEB 的用户界面来部署从该组件中提取的固件。"},{"lang":"ja","x_late":"このコンポーネントには、HPE BladeSystem c-Class Onboard Administratorのファームウェアイメージが含まれています。このファームウェアは、HPE BladeSystem c-Classエンクロージャーの管理機能を提供します。このコンポーネントとその中のファームウェアは、次のシナリオで使用することができます。1) Onboard Administratorファームウェアの展開を記述するために使用するスタンドアロンのコンポーネント 2) HPE BladeSystem c-Class Onboard Administratorにファームウェアをインストールするために、Smart Update Firmware DVD上のHPE Smart Update Managerと共同でコンポーネントを使用する 3) コンポーネントから展開したファームウェアをHPE BladeSystem c-Class Onboard AdministratorのWebベースユーザーインターフェイスを使用してインストールする"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name</strong></p>\n\n<p>HPE BladeSystem c-Class OA Firmware</p>\n\n<p><strong>Release Version</strong></p>\n\n<p>Version 4.97</p>\n\n<p><strong>Previous Version of Firmware</strong></p>\n\n<p>Version 4.96</p>\n\n<p><strong>Firmware Dependency</strong></p>\n\n<p>For firmware compatibility information,see the&nbsp;<em>HPEService Pack for ProLiant Information Library</em>at:<br />\n<a href=\"https://www.hpe.com/servers/spp/documentation\">https://www.hpe.com/servers/spp/documentation</a></p>\n\n<p><strong>Important Notes</strong></p>\n\n<ul>\n\t<li><strong>Firmware Upgrade</strong></li>\n</ul>\n\n<p>Starting OA 4.50 release, a standardized code signing and validation mechanism has been introduced to enhance the firmware image authenticity.</p>\n\n<p>For customers using Firmware ROM image to upgrade OA:</p>\n\n<p>For OA with firmware version less than 3.50, first update to OA 3.50 and then continue updating to OA 4.50 or above.</p>\n\n<p>For customers using Smart Components to upgrade OA:</p>\n\n<p>OA firmware update mechanisms which rely on HPE Smart Components (example: EFM), will not be affected by this change. The Smart Component will automatically perform the intermediate upgrade to OA 3.50 before performing the OA 4.50 or above upgrade.</p>\n\n<ul>\n\t<li><strong>Flash Disaster Recovery</strong></li>\n</ul>\n\n<p>Flash Disaster Recovery to a version of firmware 4.50 or above issupported. The behavior is seen due to the implementation of a new firmware image signing mechanism in OA firmware version 4.50 and above, which causes the FDR mechanism to see the firmware image as an invalid image.</p>\n\n<p>The workaround for this is to use Flash Disaster Recovery procedure to recover to a version of firmware prior to 4.50 and then do a firmware upgrade to the intended version (4.50 or later).</p>\n\n<ul>\n\t<li><strong>EFM</strong></li>\n</ul>\n\n<p>The OA only supports SPP ISO images that are less than 4GB in size, whether hosted directly via the Enclosure DVD feature or an attached USB key, or mounted remotely via a specified URL. If an ISO image exceeds 4 GB, the CLI SHOW FIRMWARE MANAGEMENT command displays ISO URL Status as &ldquo;Invalid URL.&rdquo;<br />\n<br />\nIf an SPP ISO image exceeds 4 GB, it is necessary to create a custom ISO image that excludes components unnecessary to the OA EFM blade firmware update process.&nbsp; At a minimum, the custom ISO must contain the firmware components for HPE ProLiant BL servers. (When using HPE SUM to create the custom ISO image, select Firmware as the Component Type, and select HPE ProLiant BL Series as the Server Type.)&nbsp; For information about creating a custom ISO image compatible for OA EFM functionality, see the&nbsp;<em>HPE BladeSystem Onboard Administrator User Guide</em>. More HPE SUM information can be found via HPE Smart Update Manager online help or at the HPE Smart Update Enterprise Information Library (<a href=\"http://www.hpe.com/info/hpsum/documentation\">http://www.hpe.com/info/hpsum/documentation</a>).</p>\n\n<ul>\n\t<li><strong>FIPS</strong></li>\n</ul>\n\n<p>Onboard Administrator 4.71 is FIPS certified as referenced in the 140-2 In Process list located at <a href=\"http://csrc.nist.gov/groups/STM/cmvp/documents/140-1/140InProcess.pdf\">http://csrc.nist.gov/groups/STM/cmvp/documents/140-1/140InProcess.pdf</a>.</p>\n\n<ul>\n\t<li><strong>IPv6</strong></li>\n</ul>\n\n<p>When the Enable DHCPv6, Enable Router Advertisements, or Enable SLAAC enclosure IPv6 settings are disabled on the Onboard Administrator, the respective DHCPv6 or SLAAC addresses of the iLOs in the enclosure are retained until these addresses expire automatically based on their respective configurations.&nbsp; A manual reset of the iLO releases these addresses immediately.</p>\n"}],"files":[{"bytes":"31530472","datemodified":"2021-01-28T15:23:34","file_list":["archives/","archives/hpoa350.bin","cp046217.xml","cp_data.xml","oa497.bin","oaupgrade.exe"],"md5sum":"846c6f4a9c96f5d7fa920fc4783acc15","name":"cp046217.exe","release":"2021-01-28T15:19:06","revision":"0","sha1sum":"8290f2d8103f5c74631967a529bfdc8f0d174ad9","size":"30MB","target_guids":[],"type_of_change":"1","version":"4.97"}],"id":{"product":"771e2c2febad408da9107df2836d8e4d","version":"70086c3a4faf40419d579e87c25c79aa"},"installation":{"command":"oaupgrade.exe","command_params":"oa497.bin","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":500,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>This component and its firmware can be used in the following scenarios:</strong></p>\n\n<ol>\n\t<li>As a stand alone component that can be used to script the deployment of the Onboard Administrator firmware</li>\n\t<li>In conjunction with the HPE Smart Update Manager found on the Smart Update Firmware DVD, the component can be used to deploy the firmware to the HPE BladeSystem c-Class Onboard Administrator</li>\n\t<li>Firmware extracted from the component can be deployed using the web-based user interface for the HPE BladeSystem c-Class Onboard Administrator</li>\n</ol>\n\n<p><strong>Installation Notes for using the component as a stand alone component</strong></p>\n\n<p>This smart component is a self-extracting executable. The smart component unpacks itself, flashes the firmware on the HPE BladeSystem c-Class Onboard Administrator, and cleans up.</p>\n\n<p>The general command line syntax for this smart component is</p>\n\n<p><br />\n&nbsp;&nbsp;&nbsp;cpxxxxxx.exe /target &lt;netAddress&gt; /user &lt;username&gt; /passwd &lt;password&gt; [/s[ilent]] [/f[orce]] [/logdir &lt;path&gt;]</p>\n\n<p><br />\nwhere cpxxxxxx.exe represents the filename of the component</p>\n\n<p>NOTE: All arguments and information enclosed in brackets are optional. If required arguments are not included on the command line, you will be prompted to provide the input.</p>\n\n<ul dir=\"ltr\">\n\t<li>&nbsp;/target &lt;netAddress&gt;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; The netAddress parameter is the IP address or DNS name of the OA to target.&nbsp; This should be the Active OA if two OA&rsquo;s are in an enclosure.&nbsp; There is a space between the /target and the netAddress parameter.</li>\n\t<li>&nbsp;/user &lt;username&gt;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;The username is the userid to use when attempting to login to the OA.&nbsp; There is a space between the /user and the username parameter.</li>\n\t<li>&nbsp;/passwd &lt;password&gt;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp; &nbsp;&nbsp;&nbsp;The password is the password for the userid to login to the OA.&nbsp; There is a space between the /passwd and the password parameter.</li>\n\t<li>&nbsp;/s[ilent]&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;The silent option will silently install the firmware, if needed.</li>\n\t<li>&nbsp;/f[orce]&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; The force option will cause the OA Flash utility to either downgrade the existing firmware or reinstall the same version of firmware on the target OA.</li>\n\t<li>&nbsp;/logdir &lt;path&gt;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; This optional parameter is used to redirect the output from the OA flash utility to a different directory&nbsp;than the default location of %SYSTEMDRIVE%\\CPQSYSTEM\\hp\\log\\&lt;netAddress&gt;. The redirected location is &lt;path&gt;\\hp\\log\\&lt;netAddress&gt;.</li>\n</ul>\n\n<p>To flash the firmware:</p>\n\n<ul>\n\t<li>&nbsp;Download the smart component file to a server which is on the same network as the HPE BladeSystem c-Class Onboard Administrator to be updated.</li>\n\t<li>&nbsp;Execute cpxxxxxx.exe /target &lt;netAddress&gt; /user &lt;username&gt; /passwd &lt;password&gt; [/s[ilent]] [/f[orce]] [/logdir &lt;path&gt;]</li>\n</ul>\n\n<p>The return codes are :</p>\n\n<ul>\n\t<li>&nbsp;0&nbsp; &nbsp;&nbsp; Success</li>\n\t<li>&nbsp;1&nbsp;&nbsp; &nbsp; Reserved</li>\n\t<li>&nbsp;2&nbsp;&nbsp; &nbsp;&nbsp;Upgrade is not needed because firmware version is current</li>\n\t<li>&nbsp;3&nbsp;&nbsp; &nbsp; Upgrade is not needed because newer firmware version is present</li>\n\t<li>&nbsp;4&nbsp;&nbsp; &nbsp; Target not found</li>\n\t<li>&nbsp;5&nbsp;&nbsp;&nbsp; &nbsp;User terminated session</li>\n\t<li>&nbsp;6&nbsp;&nbsp;&nbsp;&nbsp; Incorrect parameter</li>\n\t<li>&nbsp;7&nbsp;&nbsp;&nbsp;&nbsp; General failure</li>\n</ul>\n\n<p><strong>Installation Notes for using the component with HPE Smart Update Manager and the SPP</strong></p>\n\n<ol>\n\t<li>Obtain the latest version of the SPP.</li>\n\t<li>Place the SPP on a USB key using the&nbsp;<a href=\"https://h20565.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_357c87ee9b054ad7a631d9eaba&amp;sp4ts.oid=8788686\">HPE USB Key Utility</a>.</li>\n\t<li>Place this component in the directory, /packages on the USB key.</li>\n\t<li>Place the USB key in a system which is on the same network as the Onboard Administrator to be updated.</li>\n\t<li>Launch hpsum from /packages.</li>\n\t<li>Follow the GUI to install the firmware on the Onboard Adminstrator.</li>\n</ol>\n\n<p><strong>Installation Notes for using the firmware extracted from the component</strong></p>\n\n<ol>\n\t<li>Extract the firmware binary out of the component.</li>\n\t<li>Place the firmware image file onto a system on the same network as the HPE BladeSystem c-Class Onboard Administrator.</li>\n\t<li>Log in to the Onboard Administrator&#39;s web-based user interface as an administrator. Firmware Update is available under the Active Onboard Administrator category. You may select the firmware image by entering a path to the file in the &quot;Local File&quot; field or by clicking on the &quot;Browse&quot; button to locate the firmware image on the local machine, a mapped drive, or a network share.</li>\n\t<li>Click &quot;Upload&quot; to begin the firmware update process.</li>\n</ol>\n\n<p>The user guide for the Onboard Administrator is located&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=c00705292\">here</a>.<br />\nThe user guide for the Onboard Administrator command line interface is located&nbsp;<a href=\"http://h20565.www2.hpe.com/hpsc/doc/public/display?sp4ts.oid=3188465&amp;docId=emr_na-c00702815&amp;docLocale=en_US\">here</a>.</p>\n"},{"lang":"ja","x_late":"<p><strong>このコンポーネントとその中のファームウェアは、次のシナリオで使用することができます:</strong></p>\n\n<ol>\n\t<li>Onboard Administratorファームウェアの展開を記述するために使用するスタンドアロンのコンポーネント</li>\n\t<li>HPE BladeSystem c-Class Onboard Administratorにファームウェアをインストールするために、Smart Update Firmware DVD上にあるHP Smart Update Managerと共同でコンポーネントを使用することができます。</li>\n\t<li>コンポーネントから展開したファームウェアをHPE BladeSystem c-Class Onboard AdministratorのWebベースユーザーインターフェイスを使用して展開することができます。</li>\n</ol>\n\n<p><strong>コンポーネントをスタンドアロンコンポーネントで使用する場合のインストール時の注意</strong></p>\n\n<p>このSmartコンポーネントは、自己解凍型実行可能ファイルです。Smartコンポーネントは、ファイル自身を解凍し、HPE BladeSystem c-Class Onboard Administratorのファームウェアをフラッシュした後、解凍したファイルを削除します。</p>\n\n<p>このSmartコンポーネントの一般的なコマンドラインの文法は、以下のとおりです。</p>\n\n<p><br />\n   cpxxxxxx.exe /target <netAddress> /user <username> /passwd <password> [/s[ilent]] [/f[orce]] [/logdir <path>]</p>\n\n<p><br />\ncpxxxxxx.exeは、コンポーネントのファイル名を意味します</p>\n\n<p>注記：鍵括弧でくくられたすべての引数および情報は、任意です。必要な引数がコマンドラインに含まれていない場合は、入力するようにプロンプトが表示されます。</p>\n\n<ul dir=\"ltr\">\n\t<li> /target <netAddress>           netAddressパラメーターは、ターゲットへのOAのIPアドレスまたはDNS名です。  1つのエンクロージャーに2つのOAが存在する場合は、アクティブなOAを指定する必要があります。  /targetとnetAddressパラメーターの間にはスペースが必要です。</li>\n\t<li> /user <username>               ユーザー名はOAにログインするときに使用するユーザーIDです。  /userとusernameパラメーターの間にはスペースが必要です。</li>\n\t<li> /passwd <password>            パスワードは、OAにログインするためのユーザーIDに対応するパスワードです。  /passwdとpasswordパラメーターの間にはスペースが必要です。</li>\n\t<li> /s[ilent]                                サイレントオプションは、必要な場合ファームウェアを静かにインストールします。</li>\n\t<li> /f[orce]                                forceオプションは、OAフラッシュユーティリティがターゲットOAに既存のファームウェアをダウングレード、または同じバージョンのファームウェアを再インストールするために使用します。</li>\n\t<li> /logdir <path>                     このオプションパラメーターは、OAフラッシュユーティリティからの出力をデフォルトの場所%SYSTEMDRIVE%\\CPQSYSTEM\\hp\\log\\<netAddress>ではなく、異なるディレクトリにリダイレクトするために使用します。リダイレクトされる場所は、<path>\\hp\\log\\<netAddress>です。</li>\n</ul>\n\n<p>ファームウェアをフラッシュするには、以下の手順に従ってください。</p>\n\n<ul>\n\t<li> アップデートするHPE BladeSystem c-Class Onboard Administratorと同じネットワーク上のサーバーにSmartコンポーネントファイルをダウンロードします。</li>\n\t<li> Execute cpxxxxxx.exe /target <netAddress> /user <username> /passwd <password> [/s[ilent]] [/f[orce]] [/logdir <path>]</li>\n</ul>\n\n<p>リターンコードは、以下のとおりです。</p>\n\n<ul>\n\t<li> 0 成功</li>\n\t<li> 1 予約済み</li>\n\t<li> 2 ファームウェアのバージョンが同一のためアップグレードの必要がない</li>\n\t<li> 3  新しいバージョンのファームウェアがインストールされているためアップグレードの必要がない</li>\n\t<li> 4  ターゲットが見つからない</li>\n\t<li> 5     ユーザーによって中止されたセッション</li>\n\t<li> 6     パラメーターが不正</li>\n\t<li> 7     一般障害</li>\n</ul>\n\n<p><strong>HPE Smart Update ManagerおよびSPPとコンポーネントを使用する場合のインストール時の注意</strong></p>\n\n<ol>\n\t<li>SPPの最新バージョンを入手します。</li>\n\t<li><a href=\"https://h20565.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_357c87ee9b054ad7a631d9eaba&sp4ts.oid=8788686\">HPE USB Key Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>このコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>アップデートするOnboard Administratorと同じネットワーク上のシステムにUSBキーを接続します。</li>\n\t<li>/packagesからhpsumを起動します。</li>\n\t<li>GUIに従ってOnboard Administratorにファームウェアをインストールします。</li>\n</ol>\n\n<p><strong>コンポーネントから解凍したファームウェアを使用する場合のインストール時の注意</strong></p>\n\n<ol>\n\t<li>コンポーネントのファームウェアバイナリを展開します。</li>\n\t<li>HPE BladeSystem c-Class Onboard Administratorと同じネットワーク上のシステムにファームウェアイメージファイルをコピーします。</li>\n\t<li>Onboard AdministratorのWebベースユーザーインターフェイスに管理者でログインします。アクティブOnboard Administratorカテゴリからファームウェアのアップデートを行うことができます。［ローカルファイル］フィールドにファイルのパスを入力するか、［参照］ボタンを押してローカルマシン、割り当てられたドライブ、またはネットワーク共有から探してクリックして、ファームウェアイメージを選択します。</li>\n\t<li>［アップロード］をクリックして、ファームウェアアップデートを開始します。</li>\n</ol>\n\n<p>『Onboard Administratorユーザーガイド』は、<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&docId=c00705292\">こちら</a>にあります。<br />\n『Onboard Administratorコマンドラインインターフェイスユーザーガイド』は、<a href=\"http://h20565.www2.hpe.com/hpsc/doc/public/display?sp4ts.oid=3188465&docId=emr_na-c00702815&docLocale=en_US\">こちら</a>にあります。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Windows 的線上 HPE BladeSystem c-Class Onboard Administrator 韌體元件"},{"lang":"en","x_late":"Online HPE BladeSystem c-Class Onboard Administrator Firmware Component for Windows"},{"lang":"ko","x_late":"Windows용 온라인 HPE BladeSystem c-Class Onboard Administrator 펌웨어 구성 요소"},{"lang":"cn","x_late":"用于 Windows 的联机 HPE BladeSystem c-Class Onboard Administrator 固件组件"},{"lang":"ja","x_late":"オンラインHPE BladeSystem c-Class Onboard Administratorファームウェアコンポーネント for Windows"}],"prerequisites":{"required_diskspace":{"size_kb":"10000"},"supported_devices":[{"id":"403318-B21 ","target_guid":"","type":"other"},{"id":"437502-B21","target_guid":"","type":"other"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-03T12:17:41","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Onboard Administrator 4.96&nbsp;provides support for the following enhancements:</p>\n\n<p><strong>Hardware additions</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p>Features<strong>: additions and changes</strong></p>\n\n<p><strong>General</strong></p>\n\n<ul>\n\t<li>AlertMail feature now supports two priorities that a user can select for the AlertMail messages.</li>\n\t<li>Enclosure Firmware Management (EFM) feature is optimized to speed up the EFM update operation.</li>\n\t<li>The SSL certificate of Onboard Administrator now supports Fully Qualified Domain Name (FQDN) in <strong>Common Name</strong> (CN) field and IP address in <strong>SAN </strong>field.</li>\n\t<li>Common Access Card (CAC) Authentication feature is enhanced to support a configurable timeout for the SSL session.</li>\n</ul>\n\n<p><strong>&nbsp;Security</strong></p>\n\n<ul>\n\t<li>Onboard Administrator supports two new TLS_DHE_RSA ciphers.</li>\n\t<li>FIPS TOP-SECRET mode ciphers are now supported in FIPS <strong>ON </strong>and <strong>OFF </strong>modes.</li>\n\t<li>CLI commands SHOW SSH CIPHER, ENABLE SSH CIPHER and DISABLE SSH CIPHER are added to Show, Enable and Disable SSH ciphers in FIPS ON and OFF modes.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>General</strong></p>\n\n<ul>\n\t<li>Addressed an issue where SNMP queries to Onboard Administrator OIDs were not successfully completed when VLAN is configured for Blades and Interconnects.</li>\n\t<li>.Addressed an issue in the Device and Rack Summary GUI page to eliminate the duplicate display of FLB and Mezz adapters information.</li>\n\t<li>Addressed an issue where Interconnects were not receiving IP address from EBIPA (or) external DHCP server.</li>\n\t<li>Addressed an issue where Blade Location information was not displayed correctly in SHOW SERVER STATUS ALL CLI command.</li>\n\t<li>Addressed an issue where DNS record update was getting delayed in DNS server when a user configured a domain name in Onboard Administrator</li>\n</ul>\n\n<p><strong>Security</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Issues and workarounds</strong></p>\n\n<p><strong>Browsers</strong></p>\n\n<ul>\n\t<li>OA GUI is not accessible in Chrome versions 43.0.2357.10 to 44.0.2383.The issue was caused by a &ldquo;regression&rdquo; in Chrome (or WebKit). Customers should use an alternative browser like Firefox or Internet Explorer or try a different version of Chrome.</li>\n\t<li>SSO-to-iLO connection from the OA using an iLO host name fails with Microsoft Internet Explorer11 on Windows 8. On a Windows 8 system with Internet Explorer 10 or Internet Explorer 11, if the OA web GUI session is loaded using a host name instead of an IP address, an attempt to open an iLO window using SSO from the OA web GUI might result in the iLO page loading in the OA web GUI window instead of the intended new window. This issue was determined to be a bug in Internet Explorer and is expected to be fixed in a future release or update for Internet Explorer. To work around this issue, either use an IP address to load the OA Web GUI, or turn off Protected Mode for the appropriate zone in Internet Explorer&rsquo;s settings. This issue occurs only on Internet Explorer browsers.</li>\n</ul>\n\n<p><strong>FIPS</strong></p>\n\n<p style=\"margin-left:40px\">Certificates smaller than 2048 bits in size are not compliant with FIPS requirements as enforced by the OA firmware starting with OA 4.20. When the OA running OA firmware version 4.40 or greater is operating in FIPS Mode ON/DEBUG and is configured with a 1024-bit LDAP certificate that was installed when running a previous version of OA firmware, FIPS Mode ON/DEBUG is considered to be operating in a degraded state due to the presence of the non-compliant certificate. While operating in this FIPS-Degraded Mode operational state, attempts to set FIPS Mode OFF from the OA GUI Network Access&gt;FIPS tab will fail and show the error message The selected FIPS mode is already enabled. When the non-compliant certificate is removed, the FIPS-Degraded operational status is cleared, FIPS Mode can then be successfully set to OFF from the GUI interface. Note that the OA CLI command SET FIPS MODE OFF can be successfully used to set FIPS Mode OFF even with non-compliant 1024-bit LDAP certificates installed in the OA.</p>\n\n<p><strong>IRC</strong></p>\n\n<p style=\"margin-left:40px\">Unable to open .net IRC console for Gen10 Blades, Gen9 Blades also have the same issue. The Java applet and Webstart however, loads but the virtual media mounting fails. The work around is to launch the IRC through IRC Application (HPE&nbsp;Lights-Out Stand Alone Remote Console) which is installed on terminal client.</p>\n\n<p><strong>EFM</strong></p>\n\n<p style=\"margin-left:40px\">To use EFM on Gen 10 Blades, please select options/filters &ldquo;<em>Make Bootable ISO file&rdquo; and&nbsp;</em>&ldquo;<em>Enclosure Firmware Management&rdquo;</em>&nbsp;while creating custom SPP ISO on HPE SUM 8.0.0. Please refer to HPE SUM 8.0.0 User guide for further details.</p>\n\n<p><strong>CAC</strong></p>\n\n<ul>\n\t<li>In the CAC mode SSH, Telnet and XML Reply protocols will be disabled.</li>\n\t<li>Linked enclosure login will not work if the linked enclosure in CAC mode.</li>\n\t<li>If accurate Service account details are not provided, LDAP user login with certificate will fail.</li>\n\t<li>It is highly recommended to establish a recovery plan before getting started with CAC.&nbsp; If something goes wrong with the OA configuration, the OA may be recovered through the serial port or Insight Display panel and USB KEY. Both methods require physical access to the OA.&nbsp; However, if an LCD PIN has been configured (and forgotten) and local accounts have been disabled or CAC has been incorrectly configured then, the only way to recover is through a serial port. The two most common situations where OA recovery is needed are when LDAP has been configured incorrectly with local accounts disabled or when CAC has been configured without certificate access.</li>\n</ul>\n\n<p><strong>Configurable SSH Port Number&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong></p>\n\n<p style=\"margin-left:0in; margin-right:0in\">If a Standby OA is running firmware version less than 4.85 and it is updated to firmware version greater than or equal to 4.85 using synchronize firmware feature from Active OA, after the firmware update and reboot of the Standby OA, SSH port will not open in the configured port number. The work around is to reboot the Standby OA and SSH port will open in the configured port in next boot. This issue will not occur in the case where SSH port is configured to default port 22 in the Active OA.</p>\n"},{"curr_enhancements_x_late":"<p>Onboard Administrator 4.97&nbsp;provides support for the following enhancements:</p>\n\n<p><strong>Hardware additions</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p>Features<strong>: additions and changes</strong></p>\n\n<p><strong>General</strong></p>\n\n<ul>\n\t<li>A new feature is added to SNMP to support enable/disable options for v1/v2c protocols.</li>\n\t<li>New SNMP traps were added for emergency brake (e-brake) activated and deactivated events.</li>\n\t<li>Added support for firmware update of new NIDEC fans.</li>\n\t<li>Enhanced PowerPIC firmware update to support firmware version 1.8.</li>\n\t<li>In the Onboard Administrator GUI added support for iLO HTML5 IRC console.</li>\n</ul>\n\n<p><strong>&nbsp;Security</strong></p>\n\n<ul>\n\t<li>A new feature is added in SSH to support enable/disable of Key Exchange (KEX) Algorithms.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>General</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Addressed an issue where running concurrent UPDATE ILO cli command from different SSH sessions cause few of the commands to end in operation failure.</li>\n\t<li>Fixed an issue in SET SERVER DVD CONNECT cli command usage in IPv6 environment.</li>\n\t<li>Addressed an issue where blade&rsquo;s ProductID update in System Rom RBSU is not reflected in the Onboard Administrator.</li>\n\t<li>Harnessed certificate read operation from flash to minimize certificate read failures.</li>\n\t<li>Fixed an issue in SNMP v3 protocol where EngineTime was not reset on increment of EngineBoot count.</li>\n\t<li>Addressed an issue related to blade discovery failure</li>\n\t<li>Fixed an issue in Smart Component where it fails to establish communication with Onboard Administrator using DHE ciphers.</li>\n\t<li>Addressed an issue related to ECDSA ciphers enable/disable feature.</li>\n\t<li>Added SSH cipher list to the configuration script</li>\n\t<li>Fixed an issue in Onboard Administrator GUI where IPv4 DynamicDNS could not be enabled when enclosure is configured for static IP configuration.</li>\n\t<li>Fixed help message display issues in CLI commands SET SSL_SESSION TIMEOUT and SET SECURESH.</li>\n\t<li>Addressed an issue in SNMP where EngineBoot count was incremented by two for add/delete of trap receiver.</li>\n\t<li>Fixed Online Help (OLH) pages display issue that occur when language pack is uploaded into Onboard Administrator.</li>\n</ul>\n\n<p><strong>Security</strong></p>\n\n<p>&nbsp;</p>\n\n<p>The following security vulnerabilities are fixed:</p>\n\n<ul>\n\t<li>Onboard Administrator&rsquo;s web server response is enhanced to include X-Content-Type-Options security header.</li>\n\t<li>CVE-2011-3026 - libpng: Heap buffer overflow</li>\n\t<li>CVE-2018-1000517 - BusyBox wget version&nbsp; contains a Buffer Overflow vulnerability</li>\n\t<li>CVE-2020-1971 - EDIPARTYNAME NULL pointer de-reference</li>\n\t<li>CVE-2020-15861 - Net-SNMP allows Escalation of Privileges</li>\n\t<li>CVE-2020-15862 - Net-SNMP provides the ability to run arbitrary commands as root.</li>\n\t<li>CVE-2019-20892 &ndash; SNMPv3 get bulk request issue<br />\n\t&nbsp;</li>\n</ul>\n\n<p><strong>Issues and workarounds</strong></p>\n\n<p>&nbsp;</p>\n\n<p><strong>Browsers</strong></p>\n\n<ul>\n\t<li>OA GUI is not accessible in Chrome versions 43.0.2357.10 to 44.0.2383.The issue was caused by a &ldquo;regression&rdquo; in Chrome (or WebKit). Customers should use an alternative browser like Firefox or Internet Explorer or try a different version of Chrome.</li>\n\t<li>SSO-to-iLO connection from the OA using an iLO host name fails with Microsoft Internet Explorer11 on Windows 8. On a Windows 8 system with Internet Explorer 10 or Internet Explorer 11, if the OA web GUI session is loaded using a host name instead of an IP address, an attempt to open an iLO window using SSO from the OA web GUI might result in the iLO page loading in the OA web GUI window instead of the intended new window. This issue was determined to be a bug in Internet Explorer and is expected to be fixed in a future release or update for Internet Explorer. To work around this issue, either use an IP address to load the OA Web GUI, or turn off Protected Mode for the appropriate zone in Internet Explorer&rsquo;s settings. This issue occurs only on Internet Explorer browsers.</li>\n</ul>\n\n<p><strong>FIPS</strong></p>\n\n<p style=\"margin-left:40px\">Certificates smaller than 2048 bits in size are not compliant with FIPS requirements as enforced by the OA firmware starting with OA 4.20. When the OA running OA firmware version 4.40 or greater is operating in FIPS Mode ON/DEBUG and is configured with a 1024-bit LDAP certificate that was installed when running a previous version of OA firmware, FIPS Mode ON/DEBUG is considered to be operating in a degraded state due to the presence of the non-compliant certificate. While operating in this FIPS-Degraded Mode operational state, attempts to set FIPS Mode OFF from the OA GUI Network Access&gt;FIPS tab will fail and show the error message The selected FIPS mode is already enabled. When the non-compliant certificate is removed, the FIPS-Degraded operational status is cleared, FIPS Mode can then be successfully set to OFF from the GUI interface. Note that the OA CLI command SET FIPS MODE OFF can be successfully used to set FIPS Mode OFF even with non-compliant 1024-bit LDAP certificates installed in the OA.</p>\n\n<p><strong>IRC</strong></p>\n\n<p style=\"margin-left:40px\">Unable to open .net IRC console for Gen10 Blades, Gen9 Blades also have the same issue. The Java applet and Webstart however, loads but the virtual media mounting fails. The work around is to launch the IRC through IRC Application (HPE&nbsp;Lights-Out Stand Alone Remote Console) which is installed on terminal client.</p>\n\n<p><strong>EFM</strong></p>\n\n<p style=\"margin-left:40px\">To use EFM on Gen 10 Blades, please select options/filters &ldquo;<em>Make Bootable ISO file&rdquo; and&nbsp;</em>&ldquo;<em>Enclosure Firmware Management&rdquo;</em>&nbsp;while creating custom SPP ISO on HPE SUM 8.0.0. Please refer to HPE SUM 8.0.0 User guide for further details.</p>\n\n<p><strong>CAC</strong></p>\n\n<ul>\n\t<li>In the CAC mode SSH, Telnet and XML Reply protocols will be disabled.</li>\n\t<li>Linked enclosure login will not work if the linked enclosure in CAC mode.</li>\n\t<li>If accurate Service account details are not provided, LDAP user login with certificate will fail.</li>\n\t<li>It is highly recommended to establish a recovery plan before getting started with CAC.&nbsp; If something goes wrong with the OA configuration, the OA may be recovered through the serial port or Insight Display panel and USB KEY. Both methods require physical access to the OA.&nbsp; However, if an LCD PIN has been configured (and forgotten) and local accounts have been disabled or CAC has been incorrectly configured then, the only way to recover is through a serial port. The two most common situations where OA recovery is needed are when LDAP has been configured incorrectly with local accounts disabled or when CAC has been configured without certificate access.</li>\n</ul>\n\n<p><strong>Configurable SSH Port Number&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong></p>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong></p>\n\n<p style=\"margin-left:0in; margin-right:0in\">If a Standby OA is running firmware version less than 4.85 and it is updated to firmware version greater than or equal to 4.85 using synchronize firmware feature from Active OA, after the firmware update and reboot of the Standby OA, SSH port will not open in the configured port number. The work around is to reboot the Standby OA and SSH port will open in the configured port in next boot. This issue will not occur in the case where SSH port is configured to default port 22 in the Active OA.</p>\n\n<p style=\"margin-left:0in; margin-right:0in\">&nbsp;</p>\n\n<p><strong>Smart component</strong></p>\n\n<p>&nbsp;</p>\n\n<p style=\"margin-left:40px\">When OA is in FIPS ON or FIPS TOP-SECRET mode and any of the ciphers that use&nbsp;&nbsp;&nbsp;Diffie-Hellman (DH) keys are enabled, firmware upgrade or downgrade using OA Smart&nbsp;&nbsp;Component 4.96 or earlier versions may fail with following error:</p>\n\n<p style=\"margin-left:40px\">&nbsp;&nbsp; Error: 1013: Client cannot connect with the Onboard Administrator. Verify the target address is correct and can be accessed from your system.</p>\n\n<p>&nbsp;</p>\n\n<p style=\"margin-left:40px\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<p style=\"margin-left:80px\">FIPS ON</p>\n\n<p style=\"margin-left:80px\">TLS_DHE_RSA_WITH_3DES_EDE_CBC_SHA<br />\nTLS_DHE_RSA_WITH_AES_128_GCM_SHA25<br />\nTLS_DHE_RSA_WITH_AES_256_GCM_SHA384<br />\nTLS_DHE_RSA_WITH_AES_128_CBC_SHA256<br />\nTLS_DHE_RSA_WITH_AES_256_CBC_SHA256</p>\n\n<p style=\"margin-left:80px\">&nbsp;</p>\n\n<p style=\"margin-left:80px\">FIPS TOP-SECRET</p>\n\n<p style=\"margin-left:80px\">TLS_DHE_RSA_WITH_AES_256_GCM_SHA384</p>\n\n<p>&nbsp;&nbsp;&nbsp;</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Same error may occur when OA upgrade or downgrade is performed through Smart&nbsp;&nbsp;</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Update Manager (SUM) resulting in the following error message in the SUM.</p>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Component&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Package&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Deployment Status&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Log</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; ----------------------------------------------------------------------------------------------------------------------------------------------------------</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; cpC39063&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online HPE BladeSystem c-Class Onboard Administrator for Windows&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Update returned an error&nbsp;&nbsp;&nbsp;&nbsp; View Log</p>\n\n<p>&nbsp;</p>\n\n<p style=\"margin-left:40px\">&nbsp;&nbsp;&nbsp;When this failure occurs, the following message can be seen in the OA Smart Component&nbsp;&nbsp;log file.</p>\n\n<p style=\"margin-left:40px\">&nbsp;&nbsp; Error: 1013: Client cannot connect with the Onboard Administrator.</p>\n\n<p style=\"margin-left:40px\">&nbsp;&nbsp; Verify&nbsp;The target address is correct and can be accessed from your system.</p>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; The work-around for this problem is to disable all the ciphers that use DH&nbsp;&nbsp;key and rerun the firmware upgrade or downgrade.</p>\n\n<p style=\"margin-left:40px\">Disabling ciphers can be&nbsp;done using the CLI command DISABLE SSL CIPHER or through the GUI.&nbsp; The disabled ciphers can be re-enabled once the firmware upgrade or&nbsp;downgrade is completed.</p>\n\n<p style=\"margin-left:0in; margin-right:0in\">&nbsp;</p>\n\n<p><strong>ILO5 Firmware Update</strong></p>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; The UPDATE ILO command is failing to update the iLO5 firmware versions 2.10 and later on&nbsp;OA version 4.90 and less than 4.90. This issue is caused by the introduction of new&nbsp;&nbsp; signature in the iLO5 firmware version 2.10.</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; The work-around is to update the OA firmware&nbsp;&nbsp;to 4.95 and then try the UPDATE ILO command. This issue will not occur with OA versions&nbsp;&nbsp;4.95 and later.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"BL860ci2","value":"HP Integrity BL860c i2 Server Blade"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"BL870ci2","value":"HP Integrity BL870c i2 Server Blade"},{"key":"BL890ci2","value":"HP Integrity BL890c i2 Server Blade"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"","value":"HPE Integrity BL870c i6 Server Blade"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"BL860ci4","value":"HP Integrity BL860c i4 Server Blade"},{"key":"BL870ci4","value":"HP Integrity BL870c i4 Server Blade"},{"key":"BL890ci4","value":"HP Integrity BL890c i4 Server Blade"}],"sw_keys":[{"name":"OA","sw_key_expectedpath":"firmware:oa"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for supported HPE Mellanox adapter cards."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"10001288","datemodified":"2021-07-21T06:04:40","file_list":["./etc/bash_completion.d/mft/mft_base_autocomplete","./etc/bash_completion.d/mft/mft_help_to_completion.py","./etc/init.d/mst","./etc/mft/RPMS/mft","./etc/mft/mft.conf","./etc/mft/mst.conf","./usr/bin/flint","./usr/bin/flint_ext","./usr/bin/mcra","./usr/bin/mdevices_info","./usr/bin/mft_uninstall.sh","./usr/bin/minit","./usr/bin/mlxfwreset","./usr/bin/mlxfwstress","./usr/bin/mlxfwstress_ext","./usr/bin/mlxgearbox","./usr/bin/mlxpci","./usr/bin/mlxprivhost","./usr/bin/mst","./usr/bin/mst_cable","./usr/bin/mst_ib_add","./usr/bin/mstop","./usr/bin/resourcedump","./usr/bin/resourceparse","./usr/bin/stedump","./usr/share/man/man1","./usr/share/man/man1/flint.1.gz","./usr/share/man/man1/mcra.1.gz","./usr/share/man/man1/mdevices_info.1.gz","./usr/share/man/man1/minit.1.gz","./usr/share/man/man1/mlxfwreset.1.gz","./usr/share/man/man1/mst.1.gz","./usr/share/man/man1/mstop.1.gz","./usr/share/mft/fw_stress_db","./usr/share/mft/fw_stress_db/stress_types.db","./usr/share/mft/prm_dbs","./usr/share/mft/prm_dbs/hca","./usr/share/mft/prm_dbs/hca/ext","./usr/share/mft/prm_dbs/hca/ext/register_access_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.dat","./usr/share/mft/prm_dbs/switch","./usr/share/mft/prm_dbs/switch/ext","./usr/share/mft/prm_dbs/switch/ext/register_access_table.adb","./usr/share/mft/prm_dbs/switch/ext/register_access_table.dat","./usr/share/smartupdate/mft/component.xml"],"md5sum":"3f16e418d8af57244f67c3e8c4277457","name":"mft-4.17.0-106.sles12sp5.x86_64.rpm","release":"2021-07-21T05:53:22","revision":"0","sha1sum":"f767d137253e60d08307fb2b45fa46dd979609e9","size":"9MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0"],"type_of_change":"1","version":"4.17"},{"bytes":"20487","datemodified":"2021-07-21T06:11:50","file_list":["./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/mst_pci.ko","./lib/modules/4.12.14-120-default/updates/mst_pciconf.ko","./usr/share/smartupdate/kernel-mft-mlnx-kmp-default/component.xml"],"md5sum":"8bed09166850af44b163ca316e718676","name":"kernel-mft-mlnx-kmp-default-4.17.0_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-07-21T05:53:22","revision":"0","sha1sum":"1f3cc6ff26141fd5043c2aa3d141e2ac152400da","size":"20KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0"],"type_of_change":"1","version":"4.17"}],"id":{"product":"121737c377d94d3aa35bfe198f1f6e1f","version":"5b7b95d3a27840acb23b8c643635c94c"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using 4.12.14-120-default&nbsp;kernel or any future errata:<br />\n<br />\n<strong># rpm -Uvh kernel-mft-mlnx-kmp-default-4.17.0_k4.12.14_120-1.sles12sp5.x86_64.rpm&nbsp; mft-4.17.0-64.sles12sp5.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for SUSE Linux Enterprise Server 12 SP5 (AMD64/EM64T)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"101f","subdev":"0012","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30012","type":"pci","ven":"15b3"},{"dev":"101f","subdev":"0007","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30007","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T18:00:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","latest_fixes_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n"},{"curr_enhancements_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","curr_fixes_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"mft","sw_key_expectedpath":"software:rpm"},{"name":"kernel-mft-mlnx-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mft","sw_key_expectedpath":"software:rpm"},{"name":"kernel-mft-mlnx-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6298369","datemodified":"2021-05-18T00:58:27","file_list":["./usr/lib/i386-linux-gnu/firmware-system-u13-2.90_2021_04_29-1.1","./usr/lib/i386-linux-gnu/firmware-system-u13-2.90_2021_04_29-1.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-system-u13-2.90_2021_04_29-1.1/.setup","./usr/lib/i386-linux-gnu/firmware-system-u13-2.90_2021_04_29-1.1/CP047889.xml","./usr/lib/i386-linux-gnu/firmware-system-u13-2.90_2021_04_29-1.1/U13_2.90_04_29_2021.signed.flash","./usr/lib/i386-linux-gnu/firmware-system-u13-2.90_2021_04_29-1.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-system-u13-2.90_2021_04_29-1.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP047889.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP047889.scexe"],"md5sum":"0278c5c985c1c94240b7adceeb1bc0cf","name":"firmware-system-u13-2.90_2021_04_29-1.1.i386.rpm","release":"2021-05-18T00:45:06","revision":"0","sha1sum":"43cf411943471d97eb69e19e0daf1e71a842d826","size":"6MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021"}],"id":{"product":"b5d6bf00c2934921ba03955fbaab210d","version":"22ba35e269a74e71ac32527fe415f048"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HPE ProLiant Agentless Management Service (<strong>AMS</strong>) and HPE SNMP Agents (<strong>SNMP Agents</strong>) are both running.&nbsp; HPE does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager 8.0.0 or later, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、iLOとの通信ができない場合に失敗します。  これは、HPE ProLiant Agentless Management Service (<strong>AMS</strong>)およびHPE SNMPエージェント(<strong>SNMP Agents</strong>)の両方が実行されているときに発生します。  HPEでは、AMSおよびSNMPエージェントを同時に実行させないことを推奨します。  「iLO device not found」エラーが発生した場合、AMSまたはSNMPエージェントを停止させて、再度フラッシュコンポーネントを実行します。<br />\n<br />\n<br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上のSmart Update Manager 8.0.0以降を使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant XL230a/XL250a Gen9 (U13) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant XL230a/XL250a Gen9(U13)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Oracle Linux 7","platform":"Oracle Enterprise Linux","sr":"OEM"},{"major":"6","minor":"0","name":"Oracle Linux 6 (AMD64/EMT64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-06T15:33:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","latest_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358.  These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390.  These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"}],"sw_keys":[{"name":"U13","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900374","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the boot BIOS and firmware of HPE QLogic Mezzanine Fibre Channel host bus adapters."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"2328049","datemodified":"2021-08-31T07:43:15","file_list":["./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/.setup","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/CP048714.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/adapters.properties","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/hld60404.bin","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/payload.json","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/qlafwupdate","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/qlafwupdate.properties","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/qlafwupdate.txt","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/reference.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/setup","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x103Cx1939","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x103Cx1939/BC26xx.DAT","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x103Cx1939/FWA83xxB.DAT","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x1590x00F9","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x1590x00F9/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x1590x00F9/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x1590x00F9/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x1590x00FA","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x1590x00FA/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x1590x00FA/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x1590x00FA/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x1590x0203","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x1590x0203/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x1590x0203/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x1590x0203/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x1590x0204","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x1590x0204/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x1590x0204/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x1590x0204/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x1590x022D","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x1590x022D/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x1590x022D/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x1590x022D/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x1590x02BC","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048714.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048714.scexe"],"md5sum":"61ee676cea2e028cfa0d0df5eaeaaae4","name":"firmware-fc-mezz-qlogic-2021.10.01-1.6.x86_64.rpm","release":"2021-08-31T07:32:37","revision":"0","sha1sum":"0120033f57c79e9d9c7c5c90d8f64d9b04abd0a3","size":"2MB","target_guids":[],"type_of_change":"1","version":"2021.10.01"}],"id":{"product":"e44a20e2382c456194500cdf84c4b2b3","version":"292fdfca3a97433cb428092c9c23b87a"},"installation":{"command":"installer","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Firmware installation is a two-step process.&nbsp; Install the firmware installation tool rpm, then execute the installed tool to update the firmware.<br />\n&nbsp;<br />\n1. Install the firmware installation tool:&nbsp; rpm -Uhv &lt;rpm_package_name&gt;.rpm&nbsp; This extracts the firmware installation tool to /usr/lib/x86_64-linux-gnu (64-bit systems)&nbsp;in an firmware-* folder.<br />\n&nbsp;<br />\n2. cd to the appropriate location for your system, and update the firmware by executing ./.setup<br />\n&nbsp;<br />\nWhen the firmware installation completes, you may remove the firmware installation tool from your system using the rpm -e command.<br />\n&nbsp;</p>\n\n<p>NOTE: During the flash operation, the message &quot;No Adapter Found!&quot; may appear in the logs. These messages do not indicate a problem with the firmware flash operation and may be ignored.</p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>\n\t<p>It is advised to provide read-write permissions on /var/tmp folder. Firmware deployment via Service Pack for ProLiant(SPP) might be unsuccessful in some cases , if read-write(rw) permissions are not enable on /tmp or /var/tmp directories.</p>\n\t</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for QLogic Mezzanine Fibre Channel Host Bus Adapters - Linux (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-18T06:27:19","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated&nbsp;the Firmware/BIOS/UEFI packages for&nbsp;16 Gb&nbsp;products.</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>MBI</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE QMH2672 16Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>6.04.04</td>\n\t\t\t<td>8.08.232</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.43</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"QLOGIC","sw_key_expectedpath":"firmware:QLOGIC"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWWQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNETG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757575155","Version":"HPG2"},{"DeviceName":"MB006000GWWQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNETG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304757575154","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB008000GWWQU and MB006000GWWQT"},{"lang":"ja","x_late":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB008000GWWQUおよびMB006000GWWQT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MB008000GWWQU and MB006000GWWQT Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"3767336","datemodified":"2021-07-25T20:03:35","file_list":["cp048648.xml","cpqsetup.exe","payload.json","SCIMARRNETG2.rel","setup.dll"],"md5sum":"4402bdc8bed15aca99f9a5ce74afe989","name":"cp048648.exe","release":"2021-07-25T19:56:04","revision":"0","sha1sum":"af22f00734f36fa5988cc5a285c9e2570788f663","size":"3MB","target_guids":["4d2340a5-3042-3830-3030-304757575155","4d2340a5-3042-3630-3030-304757575154"],"type_of_change":"1","version":"HPG2"}],"id":{"product":"c65e02b4990e43eea4fa2402b45960eb","version":"fb60773c9c834ebc8a6d9dda216daed4"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB008000GWWQU and MB006000GWWQT Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB008000GWWQUおよびMB006000GWWQTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB008000GWWQU","target_guid":"4d2340a5-3042-3830-3030-304757575155","type":"sata"},{"id":"MB006000GWWQT","target_guid":"4d2340a5-3042-3630-3030-304757575154","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T18:27:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>&nbsp;Added support for Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000GWWQT","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB008000GWWQU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6258219","datemodified":"2021-05-18T04:05:59","file_list":["./usr/lib/i386-linux-gnu/firmware-system-u15-2.90_2021_04_29-1.1","./usr/lib/i386-linux-gnu/firmware-system-u15-2.90_2021_04_29-1.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-system-u15-2.90_2021_04_29-1.1/.setup","./usr/lib/i386-linux-gnu/firmware-system-u15-2.90_2021_04_29-1.1/CP047856.xml","./usr/lib/i386-linux-gnu/firmware-system-u15-2.90_2021_04_29-1.1/U15_2.90_04_29_2021.signed.flash","./usr/lib/i386-linux-gnu/firmware-system-u15-2.90_2021_04_29-1.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-system-u15-2.90_2021_04_29-1.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP047856.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP047856.scexe"],"md5sum":"4bae6f0db7cc30309c5aad222759c7ff","name":"firmware-system-u15-2.90_2021_04_29-1.1.i386.rpm","release":"2021-05-18T03:55:05","revision":"0","sha1sum":"d2e3d38c6560698d59d89adc2b7e16fe7e561e3d","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021"}],"id":{"product":"aba50894270544dcaa9bf4eb0a273b8c","version":"99460eb6ea1048059310f765e0c01a8d"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HPE ProLiant Agentless Management Service (<strong>AMS</strong>) and HPE SNMP Agents (<strong>SNMP Agents</strong>) are both running.&nbsp; HPE does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.</p>\n\n<p><br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager 8.0.0 or later, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、iLOとの通信ができない場合に失敗します。  これは、HPE ProLiant Agentless Management Service (<strong>AMS</strong>)およびHPE SNMPエージェント(<strong>SNMP Agents</strong>)の両方が実行されているときに発生します。  HPEでは、AMSおよびSNMPエージェントを同時に実行させないことを推奨します。  「iLO device not found」エラーが発生した場合、AMSまたはSNMPエージェントを停止させて、再度フラッシュコンポーネントを実行します。<br />\n<br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。</p>\n\n<p><br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上のSmart Update Manager 8.0.0以降を使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant DL60 Gen9/DL80 Gen9 (U15) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant DL60 Gen9/DL80 Gen9（U15）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-05T03:56:34","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"}],"sw_keys":[{"name":"U15","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"19300214","languages":[{"lang":"en","x_late":"Firmware (Entitlement Required) - Storage Controller"},{"lang":"ja","x_late":"ファームウェア (ライセンスが必要) - ストレージコントローラー"}]}],"description":[{"lang":"tw","x_late":"此套件可更新連接智慧陣列控制器及主機匯流排配接卡的 HP D2600 與 D2700 磁碟機機櫃韌體。此套件內含的 I/O 模組韌體新增改善功能，可修正在初版產品發行後使用與額外資格測試期間發現的問題。"},{"lang":"en","x_late":"This package updates the firmware on HP D2600 and D2700 Disk enclosures attached to Smart Array Controllers and Host Bus Adapters. I/O module firmware included in this package adds improvements and corrects issues found during use and additional qualification testing after initial product release."},{"lang":"ko","x_late":"이 패키지는 스마트 어레이 컨트롤러 및 호스트 버스 어댑터에 장착되어 있는 HP D2600 및 D2700 디스크 인클로저의 펌웨어를 업데이트합니다. 이 패키지에 포함된 I/O 모듈 펌웨어에서는 제품 출시 후 사용 또는 추가 적격 테스트 과정에서 발견된 문제를 수정하고 개선 사항을 추가하였습니다."},{"lang":"cn","x_late":"该软件包用于更新连接至智能阵列控制器和主机总线适配器的HP D2600和D2700磁盘机柜固件。此软件包中包含的 I/O 模块固件添加了改进，并纠正了首次产品发布后在使用期间及额外资格测试时发现的问题。"},{"lang":"ja","x_late":"このパッケージは、Smartアレイコントローラーおよびホストバスアダプターに接続されているHP D2600およびD2700ディスクエンクロージャーのファームウェアをアップデートします。 このパッケージに含まれるI/Oモジュールのファームウェアは、初期リリース後、実際の使用中および追加テストで見つかった問題の改善と修正を追加します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"2960312","datemodified":"2015-11-30T08:02:48","file_list":["./usr/lib/x86_64-linux-gnu/hp-firmware-d2600-d2700-0150-2.1","./usr/lib/x86_64-linux-gnu/hp-firmware-d2600-d2700-0150-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/hp-firmware-d2600-d2700-0150-2.1/.hpsetup","./usr/lib/x86_64-linux-gnu/hp-firmware-d2600-d2700-0150-2.1/CAMSPR0150_6G_app_4MB_ai.pmc","./usr/lib/x86_64-linux-gnu/hp-firmware-d2600-d2700-0150-2.1/CP028451.xml","./usr/lib/x86_64-linux-gnu/hp-firmware-d2600-d2700-0150-2.1/ccissflash","./usr/lib/x86_64-linux-gnu/hp-firmware-d2600-d2700-0150-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-firmware-d2600-d2700-0150-2.1/libstdc++.so.6","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP028451.scexe"],"md5sum":"4763adebb00e8b4fead750c8ebf16e6d","name":"hp-firmware-d2600-d2700-0150-2.1.x86_64.rpm","release":"2016-10-07T00:00:00","revision":"1","sha1sum":"265814f2e52f86301c88e0c088e97fe9573cf42f","size":"2MB","target_guids":[],"type_of_change":"1","version":"0150"}],"id":{"product":"ca5f8e8ad5cf4c9a9aaf2d63a599d335","version":"204b1cb605dc4eb9b666b1fd2975df06"},"installation":{"command":"hpsetup","command_params":"-iCAMSPR0150_6G_app_4MB_ai.pmc -v0150 -t\"D2600 SAS AJ940A\" -t\"D2700 SAS AJ941A\" -t\"260 SAS AJ940A\" -t\"270 SAS AJ941A\" -t\"D2x00 Disk Enc.\" -t\"MDS260 CAMARO\" -t\"MDS270 CAMARO\"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Firmware installation instructions for Smart Array configurations:</strong></p>\n\n<p><strong><em>Updating firmware with rpm installed:</em></strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The&nbsp;CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;hp-firmware-d2600-d2700-&lt;version&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:&nbsp;</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./hpsetup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/hp-firmware-d2600-d2700-&lt;version&gt;-*&#39; location</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p><strong>To use HP Smart Update Manager from the HP Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hp.com/go/spp\" style=\"text-decoration: none; color: blue;\"><u>HP Service Pack for ProLiant&nbsp;</u></a>on a USB key using the&nbsp;<a href=\"http://www.hp.com/swpublishing/MTX-40e268a99cc243a299352b7b20\" style=\"text-decoration: none; color: blue;\"><u>HP USB Key Creator Utility</u></a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/hp/swpackages on the USB key.</li>\n\t<li>Boot from the newly created HP Service Pack for ProLiant USB key.</li>\n\t<li>Follow HP Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root (You must be root in order to apply the ROM update).</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/hp/swpackages.</li>\n\t<li>Run the launch_hpsum.sh in the root of the ISO.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>Special installation instructions for single-domain environments:</strong></p>\n\n<p>In a single domain configuration, I/O module A (top module) is connected to a SmartArray controller and I/O module B (bottom module) is unused. Even though the bottom I/O module is unused, both modules must have the same firmware version installed. Do the following to make sure that BOTH I/O modules are updated:</p>\n\n<ol>\n\t<li>Flash I/O module A of the first and all cascaded disk enclosures using the firmware upgrade executable.</li>\n\t<li>After I/O module A is flashed successfully in the disk enclosures, shut down and turn off the server.</li>\n\t<li>Remove A/C power to the first and all cascaded disk enclosures.</li>\n\t<li>Label all cables connected to I/O module A of the first and all cascaded disk enclosures and then disconnect all cables from the I/O modules.</li>\n\t<li>Swap the positions of the I/O modules in the enclosure.</li>\n\t<li>Reconnect the cables to the top I/O module (it used to be the bottom I/O module) in the enclosure, using the labels to ensure that all cabling is connected properly, in the same configuration as before.</li>\n\t<li>Turn on the storage enclosures and wait for them to complete their startup routines.</li>\n\t<li>Turn on the server.</li>\n\t<li>After the server startup procedure is complete, flash the top I/O module (the new I/O module A) of first and all cascaded disk enclosures using the firmware upgrade executable.</li>\n\t<li>After the I/O module is flashed successfully in the disk enclosures, power cycle the server to resume normal operation.</li>\n</ol>\n\n<p><strong>NOTES:</strong></p>\n\n<ul>\n\t<li>Use the -e or -f option when flashing a device, even if it is up to date.</li>\n\t<li>Use the -g option when downgrading.</li>\n\t<li>For details on supported command options, see the online help by executing the command ./CP0xxxxx.scexe or ./CP0xxxxx.scexe -h.</li>\n</ul>\n\n<p><strong>Installation Notes and Best Practices:</strong></p>\n\n<ul>\n\t<li>Before installing new firmware, review system requirements, enhancements list, fixes list, and other information in the firmware release notes, device QuickSpecs, and updated user documentation.</li>\n\t<li>Before installing new firmware, ensure that the system is stable and is not being reconfigured or changed in any way. If changes are in progress, monitor them and wait until they are completed before proceeding with the upgrade.</li>\n\t<li>Before installing new firmware, HP recommends creating a full backup of all data stored on the enclosure.</li>\n\t<li>When planning for a firmware update, schedule an appropriate time to perform an the update. Firmware updates must be performed during a system maintenance window, with all I/O to the system halted.</li>\n\t<li>After the installation process, verify system status in the software tools and confirm that the new firmware version is displayed as running on the enclosure.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>Smartアレイ構成のためのファームウェアのインストール手順：</strong></p>\n\n<p><strong><em>rpmインストールによるファームウェアのアップデート：</em></strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンドを使用して、ファームウェアrpmをインストールします：  <em>rpm -ivh <rpm_filename>。  </em>これは、'/usr/lib/x86_64-linux-gnu'へrpm の内容を解凍します。</li>\n\t<li>CP0xxxxx.scexeスクリプトは、'hp-scexe-compat'フォルダーにあります。'hp-firmware-smartarray-d6000-<version>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます</li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>一つ</strong>を実行することができます： </li>\n</ul>\n\n<p>               # ./CP0xxxxx.scexe ('/usr/lib/x86_64-linux-gnu/hp-scexe-compat'で実行)  (または)</p>\n\n<p>               # <em>./hpsetup</em> in the '/usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-d2700-<version>-*' location</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、次のコマンドを実行します： <em>rpm -e <rpm_package_name></em>、'.rpm'拡張子無しのrpmファイル名です。</li>\n</ul>\n\n<p><strong>HP Smart Update Managerを使用するには、HP Service Pack for ProLiantから以下の手順に従ってください:</strong><br />\n<br /> <strong>オフライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://www.hp.com/swpublishing/MTX-40e268a99cc243a299352b7b20\" style=\"text-decoration: none; color: blue;\"><u>HP USB Key Utility</u></a>を使用して、<a href=\"http://www.hp.com/go/spp\" style=\"text-decoration: none; color: blue;\"><u>HP Service Pack for ProLiant</u></a>をUSBキーに設置します。</li>\n\t<li>アップデートするファームウェアをUSBキーの/SPP20xxxxx/hp/swpackagesディレクトリにコピーします。</li>\n\t<li>新たに作成したHP Service Pack for ProLiant USBキーから起動します。</li>\n\t<li>HP Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ルートでログイン（ROMアップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>アップデートに必要なファームウェアをSPP20xxxxx/hp/swpackagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある launch_hpsum.shを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n\n<p> </p>\n\n<p><strong>シングルドメイン環境での特別なインストール手順</strong></p>\n\n<p>シングルドメインの構成では、I/OモジュールA（上側のモジュール）は、Smartアレイコントローラーに接続し、I/OモジュールB（下側のモジュール）は使用されません。たとえ下側のI/Oモジュールが使われない場合でも、両方のモジュールは同じファームウェアバージョンがインストールされていなければなりません。必ず両方のI/Oモジュールがアップデートされるように、以下を実行してください。</p>\n\n<ol>\n\t<li>実行可能なファームウェアアップグレードを使用して、最初のI/OモジュールAと全てのカスケードされたディスクエンクロージャーをフラッシュしてください。</li>\n\t<li>ディスクエンクロージャーでI/OモジュールAのフラッシュが成功した後、シャットダウンしてサーバーの電源を落とします。</li>\n\t<li>最初にA/C電源を、次にカスケードされた全てのディスクエンクロージャーを取り外します。</li>\n\t<li>最初のI/OモジュールAとカスケードされた全てのディスクエンクロージャーに接続されたケーブルにラベルを記載します。そして、I/Oモジュールからケーブルを取り外します。</li>\n\t<li>エンクロージャー内のI/Oモジュールの位置を交換します。</li>\n\t<li>以前の構成と同じように、全てのケーブル接続が正しいかラベルを確認して、エンクロージャー内の上側I/Oモジュール（下側I/Oモジュールとして使われていたもの）にケーブルを再接続します。</li>\n\t<li>ストレージエンクロージャーの電源を入れて、スタートアップルーチンの完了を待ちます。</li>\n\t<li>サーバーの電源を入れます。</li>\n\t<li>サーバーのスタートアッププロシジャーが完了後、実行可能なファームウェアアップグレードを使用して最初の上側I/Oモジュール（新しいI/OモジュールA）とカスケードされた全てのディスクエンクロージャーをフラッシュしてください。</li>\n\t<li>ディスクエンクロージャー内のI/Oモジュールのフラッシュが成功した後、通常の動作に戻すため、サーバーの電源を入れ直します。</li>\n</ol>\n\n<p><strong>注:</strong></p>\n\n<ul>\n\t<li>それが最新であっても、デバイスをフラッシュするときには-eか-fオプションを使用してください。</li>\n\t<li>ダウングレードするときは、-gオプションを使用してください。</li>\n\t<li>サポートされているコマンド オプションの詳細は、\"./CP0xxxxx.scexe\" あるいは、\"./CP0xxxxx.scexe -h\"コマンドを実行してオンライン ヘルプを参照してください。</li>\n</ul>\n\n<p><strong>インストールノートおよびベストプラクティス</strong></p>\n\n<ul>\n\t<li>ファームウェアをインストールする前に、システム要件、拡張リスト、修正リストおよびファームウェアリリースノート、デバイスのQuick Specs、他のユーザードキュメントの情報を確認してください。</li>\n\t<li>新しいファームウェアをインストールする前に、システムが安定していて、再設定中または変更中ではないことを確認してください。もし何らかの変更が処理中ならば、それらを監視し、処理が完了するまで待ってからアップグレードを始めてください。</li>\n\t<li>新しいファームウェアをインストールする前に、エンクロージャー上に保存されている全てのデータのフルバックアップを作成することをおすすめします。</li>\n\t<li>ファームウェアをアップグレードする場合、アップグレードを実行する適切な時間をスケジュールします。ファームウェアのアップグレードは、システムの全てのI/Oを停止して、システムをメンテナンスする期間内に行う必要があります。</li>\n\t<li>インストールプロセス後、ソフトウェアツールのシステムステータスの確認と新しいファームウェアバージョンがエンクロージャー上で実行中と表示されることを確認してください。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Linux (x64) 的 HP D2600/D2700 6Gb SAS 磁碟機櫃 ROM 更新元件"},{"lang":"en","x_late":"HP D2600/D2700 6Gb SAS Disk Enclosure ROM Flash Component for Linux (x64)"},{"lang":"ko","x_late":"Linux (x64)용 HP D2600/D2700 6Gb SAS 디스크 인클로저 ROM 플래시 구성 요소"},{"lang":"cn","x_late":"用于Linux (x64)的HP D2600/D2700 6Gb SAS磁盘机柜ROM刷新组件"},{"lang":"ja","x_late":"HP D2600/D2700 6Gb SASディスクエンクロージャーROMフラッシュコンポーネント for Linux (x64)"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"id":"D2600 SAS AJ940A","target_guid":"","type":"msa"},{"id":"D2700 SAS AJ941A","target_guid":"","type":"msa"}],"supported_operating_systems":[{"major":"5","minor":"0","name":"Red Hat Enterprise Linux 5 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"10","minor":"0","name":"SUSE LINUX Enterprise Server 10 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-05-10T07:48:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>The following fix is added in this version:-</strong></p>\n\n<p>-Removed action over FAULT_SENSED bit due to incorrect algorithm.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>The following fix is added in this version:-</strong></p>\n\n<p>-Removed action over FAULT_SENSED bit due to incorrect algorithm.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"}],"sw_keys":[{"name":"D2700","sw_key_expectedpath":"firmware:QLOGIC"},{"name":"D2600","sw_key_expectedpath":"firmware:QLOGIC"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JWXKH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG08scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a57584b48","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB016000JWXKH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;-&nbsp;MB016000JWXKH Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"5563143","datemodified":"2021-07-26T15:57:33","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPD9-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPD9-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPD9-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPD9-2.1/CP049125.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPD9-2.1/TAMG08scHPD9.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPD9-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPD9-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPD9-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPD9-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049125.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049125.scexe"],"md5sum":"0f3407ec9e7147e68f636e107df84d7b","name":"firmware-hdd-8a0371a425-HPD9-2.1.x86_64.rpm","release":"2021-07-26T15:44:07","revision":"0","sha1sum":"0fc910989da04f75be3a1bb17f317433e9ea3d3e","size":"5MB","target_guids":["4d2340a5-3042-3631-3030-304a57584b48"],"type_of_change":"1","version":"HPD9"}],"id":{"product":"aa62b707fef04bb99492053e558daffb","version":"471351bfe45d463b98131b92e91c96cc"},"installation":{"command":"CP040352.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB016000JWXKH Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB016000JWXKH","target_guid":"4d2340a5-3042-3631-3030-304a57584b48","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T15:39:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB016000JWXKH","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GWAYN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHHaseFG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-30475741594e","Version":"HPG5"},{"DeviceName":"MB008000GWAYL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHHaseFG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-30475741594c","Version":"HPG5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB010000GWAYN and MB008000GWAYL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB010000GWAYN and MB008000GWAYL Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG4</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>This code corrects a potential data integrity issue related to unaligned write commands.This issue was only found in supplier ongoing lab testing.</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"4181456","datemodified":"2021-07-23T11:56:45","file_list":["cp048671.xml","cpqsetup.exe","HLIBRHHaseFG5.rel","payload.json","setup.dll"],"md5sum":"d85a8df3d24d1eaac029c09986ff49e1","name":"cp048671.exe","release":"2021-07-23T11:47:07","revision":"0","sha1sum":"7dfb4f2a6a6bbd3ab3450dd978f30b63c3c0173b","size":"3MB","target_guids":["4d2340a5-3042-3031-3030-30475741594e","4d2340a5-3042-3830-3030-30475741594c"],"type_of_change":"2","version":"HPG5"}],"id":{"product":"70cd98996b234f1990b49a33858ae471","version":"c077cfcf59984d1f9f3243bfc722b64e"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration-line: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB010000GWAYN and MB008000GWAYL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows(x64) - MB010000GWAYNおよびMB008000GWAYLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB010000GWAYN","target_guid":"4d2340a5-3042-3031-3030-30475741594e","type":"sata"},{"id":"MB008000GWAYL","target_guid":"4d2340a5-3042-3830-3030-30475741594c","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-17T08:25:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":"<ul>\n\t<li>This code corrects a potential data integrity issue related to unaligned write commands.This issue was only found in supplier ongoing lab testing.Â </li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This code corrects a potential data integrity issue related to unaligned write commands.This issue was only found in supplier ongoing lab testing.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB010000GWAYN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB008000GWAYL","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000JEFRB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVNGSD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-304a45465242","Version":"HPD9"},{"DeviceName":"MM2000JEFRC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVNGSD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-324d-3030-304a45465243","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MM1000JEFRB and MM2000JEFRC"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MM1000JEFRBおよびMM2000JEFRC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MM1000JEFRB and MM2000JEFRC Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD8<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5475704","datemodified":"2021-07-23T07:53:40","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPD9-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPD9-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPD9-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPD9-2.1/CP048180.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPD9-2.1/SAVNGSD9.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPD9-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPD9-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPD9-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPD9-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048180.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048180.scexe"],"md5sum":"3bd2d27d1e745bc7f030470f1e114933","name":"firmware-hdd-b04257b77b-HPD9-2.1.x86_64.rpm","release":"2021-07-23T07:37:05","revision":"0","sha1sum":"9399a1e1b648dc55f0ff8105290f4de5e8c596a4","size":"5MB","target_guids":["002340a5-4d00-314d-3030-304a45465242","002340a5-4d00-324d-3030-304a45465243"],"type_of_change":"1","version":"HPD9"}],"id":{"product":"4cf79b782386458fa01aea2ca94f4962","version":"c99e0b57016c4a9391476f2664d65dfb"},"installation":{"command":"CP040271.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64)  - MM1000JEFRB and MM2000JEFRC Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MM1000JEFRBおよびMM2000JEFRCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MM1000JEFRB","target_guid":"002340a5-4d00-314d-3030-304a45465242","type":"sas"},{"id":"MM2000JEFRC","target_guid":"002340a5-4d00-324d-3030-304a45465243","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T20:36:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MM2000JEFRC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MM1000JEFRB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Mellanox CX4LX and CX5 Ethernet NICs for Microsoft Windows Server 2012 R2."},{"lang":"ja","x_late":"このコンポーネントパッケージは、HPE Mellanox CX4LXおよびCX5 Ethernet NIC for Microsoft Windows Server 2012 R2用のドライバーを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1943776","datemodified":"2021-02-09T07:37:01","file_list":["cp045130.xml","cpqsetup.exe","cp_data.xml","install.xml","mlx5.cat","mlx5.inf","mlx5.sys","mlx5ui.dll","nicdrvr.dll"],"md5sum":"43e5b5f6d99c639195861c9824d6e03a","name":"cp045130.exe","release":"2021-02-09T07:22:10","revision":"0","sha1sum":"caad16621a109b2065895a0b7d767a9561aa5e32","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"type_of_change":"0","version":"2.60.23957.0"}],"id":{"product":"4f88f457c2f54e169ae4af95c2b1199f","version":"8cc616e5d3184452b20245ea5acad6b2"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"tw","x_late":"將智慧型元件下載至硬碟上的目錄，並變更至該目錄。<p>從該磁碟及目錄，執行下載的檔案。<p>按一下「Install」(安裝) 按鈕，繼續執行安裝程序。<br>"},{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ko","x_late":"스마트 구성 요소를 하드 드라이브의 디렉터리로 다운로드하고 그 디렉터리로 이동합니다.<p>드라이브와 디렉터리에서 다운로드한 파일을 실행합니다.<p>설치 버튼을 클릭하여 설치 작업을 시작합니다.<br>"},{"lang":"cn","x_late":"将智能组件下载到硬盘目录中，然后转至该目录。<p>在该硬盘目录中，执行下载的文件。<p>点击安装按钮继续执行安装。<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Mellanox CX4LX and CX5 Driver for Microsoft Windows Server 2012 R2"},{"lang":"ja","x_late":"HPE Mellanox CX4LXおよびCX5ドライバー for Microsoft Windows Server 2012 R2"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"1018","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101815900282","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1014","subdev":"00c7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1014159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1014","subdev":"00c8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1014159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"1016","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1016159002c1","type":"pci","ven":"15B3"},{"dev":"1016","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1016159002c1","type":"pci","ven":"15B3"},{"dev":"1016","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1016159000d3","type":"pci","ven":"15B3"},{"dev":"1016","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1016159000d4","type":"pci","ven":"15B3"},{"dev":"1018","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101815900246","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ol>\n\t<li>The number of VMs is limited to 124 VMs with VMQ(Virtual Machine Queue) mode.</li>\n\t<li>The driver supports up to 200 vPorts in ConnectX-4 Lx and 254 vPorts in ConnectX-5 with SRIOV(Single Root I/O Virtualization).</li>\n</ol>\n","latest_fixes_x_late":"<ol>\n\t<li>This product correct an issue which caused memory corruption in case the OS provided continues memory across multiple pages that did not start with offset zero on aligned memory address.</li>\n\t<li>This product correct an issue that prevented the device from being updated with the new driver because the driver was already in the driver store.</li>\n\t<li>This product correct an issue which occasionally prevented the VF counters from being displayed correctly in perfmon.</li>\n\t<li>This product correct an issue which caused the driver to report zero link speeds supported when working with firmware older than 1x.18.0240.</li>\n\t<li>This product correct an issue which fixed a memory leak issue in error flow during driver initialization.</li>\n</ol>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product addresses a Windows Stop Error (BSOD) seen when running Mellanox NdStat Utility (mlx5cmd -ndstat) while ND connections was closing.</li>\n\t<li>This product corrects driver loading failures seen due to incorrect INF file.</li>\n\t<li>This product correct an issue where the vSwitch unavailable to assign on WS2012R2.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"mlx5.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The Smart Storage Administrator Diagnostic Utility CLI is a commandline-based disk configuration program for Smart Array and SmartRAID Controllers and any supported devices, including providing SmartSSD Wear Gauge information for supported drives."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p>Running SSADUCLI<br />\n------------------------------------------------------------------------<br />\nTo run the command-line application:&nbsp;&nbsp;&nbsp;<br />\n&nbsp;&nbsp; Open a command prompt and change directory (cd) to the location<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; where SSADUCLI is installed.&nbsp; This is commonly<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; C:\\Program Files\\Smart Storage Administrator\\ssaducli\\bin.<br />\n&nbsp;&nbsp; To generate a diagnostic report, enter the following command:</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; ssaducli -f adu-report.zip</p>\n\n<p>&nbsp;&nbsp; To generate a SmartSSD Wear gauge report, enter the following command:</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; ssaducli -ssdrpt -f ssd-report.zip<br />\n&nbsp;&nbsp;<br />\n&nbsp;&nbsp; More options can be found by &quot;ssaducli -help&quot;.<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br />\nAdditional Notes<br />\n----------------<br />\nBoth the diagnostic and SmartSSD wear gauge reports are generated in compressed<br />\n&nbsp; (ZIP) format.</p>\n\n<p>The diagnostic report output archive contains the following files:</p>\n\n<p>&nbsp;&nbsp; * ADUReport.txt&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; =&gt; Diagnostic report in text format<br />\n&nbsp;&nbsp; * ADUReport.xml&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; =&gt; Diagnostic report in XML format<br />\n&nbsp;&nbsp; * ADUReport.htm&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; =&gt; HTML viewer for diagnostic report<br />\n&nbsp;&nbsp; * report.checksum&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; =&gt; checksum file<br />\n&nbsp;&nbsp; * SlotX.txt (SlotX.old)&nbsp; =&gt; Controller serial output log</p>\n\n<p>&nbsp;&nbsp; Note: The serial output log file(s) are only available if the &quot;HPE Smart<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Array SAS/SATA Event Notification Service&quot; is installed and running.</p>\n\n<p>&nbsp;&nbsp; To view the diagnostic report in a browser, extract the ADUReport.htm. Open<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; ADUReport.htm in the browser.</p>\n\n<p>The SmartSSD wear gauge report output archive contains the following files:</p>\n\n<p>&nbsp;&nbsp; * SmartSSDWearGaugeReport.txt&nbsp; =&gt; SmartSSD wear gauge report in text format<br />\n&nbsp;&nbsp; * SmartSSDWearGaugeReport.json =&gt; SmartSSD wear gauge report in JSON format<br />\n&nbsp;&nbsp; * SmartSSDWearGaugeReport.htm&nbsp; =&gt; HTML viewer for the JSON wear gauge report</p>\n\n<p>&nbsp;&nbsp; To view the SmartSSD wear gauge report in a browser, extract the<br />\n&nbsp;&nbsp; SmartSSDWearGaugeReport.json, SmartSSDWearGaugeReport.htm files to a<br />\n&nbsp;&nbsp; directory (both files must reside in the same directory).&nbsp; Open<br />\n&nbsp;&nbsp; SmartSSDWearGaugeReport.htm in the browser.</p>\n\n<p>Known Issues<br />\n------------<br />\n* When installing the 32-bit version of SSADUCLI on a system that has a<br />\n&nbsp; 64-bit (x64) version of SSADUCLI installed, please uninstall the 64-bit<br />\n&nbsp; version first. Failing to uninstall the 64-bit version will cause the 32-bit<br />\n&nbsp; installation to fail.</p>\n"}],"files":[{"bytes":"3376760","datemodified":"2021-08-11T13:02:44","file_list":["cp047064.xml","cpqsetup.exe","genericmsi.dll","SSADU52080_X64.msi"],"md5sum":"cb3dc45eea71845b04631490a468d96c","name":"cp047064.exe","release":"2021-08-11T13:00:12","revision":"0","sha1sum":"5d11ea9cad1405eb159dc06ac947d20c89f0e8b1","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecdf9a8250"],"type_of_change":"1","version":"5.20.8.0"}],"id":{"product":"3ac61ed209fd49fb908341fa7b77c3ea","version":"3c76a260cb2c49b0b738885dd8a18f23"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":90,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.\n<p>\n From that drive and directory, execute the downloaded file.</p>\n<p>\n Click the &quot;Install&quot; button to proceed with the installation. The utility will automatically be installed.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Windows (64 位元) 的 Smart Storage Administrator Diagnostic Utility (SSADU) CLI"},{"lang":"en","x_late":"Smart Storage Administrator Diagnostic Utility (SSADU) CLI for Windows 64-bit"},{"lang":"ko","x_late":"Windows 64비트용 스마트 스토리지 관리자 진단 유틸리티(SSADU) CLI"},{"lang":"cn","x_late":"64位Windows版Smart Storage Administrator Diagnostic Utility (SSADU) CLI"},{"lang":"ja","x_late":"Smart Storage Administrator Diagnostic Utility (SSADU) CLI for Windows 64ビット"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-09T05:22:43","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added&nbsp;support&nbsp;to the HPE&nbsp;SR932i-p and SR416-a&nbsp;Gen10 Plus&nbsp;Controllers.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2022 for HPE ProLiant Gen10 and Gen10 Plus platforms only.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U38","value":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"key":"U38","value":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"key":"","value":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"Carbondale14","value":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U14","value":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4520 Gen9 Chassis</p>\n"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"","value":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U27","value":"HPE ProLiant XL2x260w Gen9 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>\n"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"","value":"HPE ProLiant ML150 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"","value":"HPE ProLiant XL770f Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"ssaducli.exe","sw_key_expectedpath":"%ProgramFiles%\\Smart Storage Administrator\\ssaducli\\bin"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Intel ixgben Adapters running under VMware vSphere 7.0."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;1.9.4.0.</p>\n"}],"files":[{"bytes":"197055","datemodified":"2021-05-10T08:45:47","file_list":["/cp045248.xml","/Intel-ixgben_1.9.12.0-1OEM.700.1.0.15843807_17899222.zip","/Intel-ixgben_1.9.12.0-1OEM.700.1.0.15843807_17899222.zip/index.xml","/Intel-ixgben_1.9.12.0-1OEM.700.1.0.15843807_17899222.zip/vendor-index.xml","/Intel-ixgben_1.9.12.0-1OEM.700.1.0.15843807_17899222.zip/metadata.zip","/Intel-ixgben_1.9.12.0-1OEM.700.1.0.15843807_17899222.zip/vib20/ixgben/INT_bootbank_ixgben_1.9.12.0-1OEM.700.1.0.15843807.vib","/Intel-ixgben_1.9.12.0-1OEM.700.1.0.15843807_17899222.zip/metadata.zip/vendor-index.xml","/Intel-ixgben_1.9.12.0-1OEM.700.1.0.15843807_17899222.zip/metadata.zip/vmware.xml","/Intel-ixgben_1.9.12.0-1OEM.700.1.0.15843807_17899222.zip/metadata.zip/vibs/ixgben--3083509160048418717.xml","/Intel-ixgben_1.9.12.0-1OEM.700.1.0.15843807_17899222.zip/metadata.zip/bulletins/Intel-ixgben_1.9.12.0-1OEM.700.1.0.15843807.xml"],"md5sum":"e235ada2755e54d330a31618c602d9d6","name":"cp045248.zip","release":"2021-05-10T08:43:03","revision":"0","sha1sum":"cb81e97e9c796b3430ce25d6d1bfb8186e1e83d4","size":"192KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4a9c3d5c","20a6e8e4-bf33-4c71-a6bf-d9ec6164afab"],"type_of_change":"0","version":"2021.04.05","vib_list":[{"name":"ixgben","version":"1.9.12.0-1OEM.700.1.0.15843807"}]}],"id":{"product":"8dc1af4f4f75416590a7ddb9bd07a92c","version":"8e5604aad9a44729a5ac851aeeca0505"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバーにUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel ixgben Driver for VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c192d","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c211a","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d3","type":"pci","ven":"8086"},{"dev":"1515","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c192d","type":"pci","ven":"8086"},{"dev":"1515","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c211a","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product corrects the maximum supported number of virtual functions.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"ixgben:1.9.12.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"Intel-ixgben:1.9.12.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver.component:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000JFEPA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRAND5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a46455041","Version":"HPD5"},{"DeviceName":"MB4000JFEPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRAND5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a46455042","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB2000JFEPA and MB4000JFEPB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB2000JFEPA and MB4000JFEPB Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD2</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong>&nbsp;&nbsp;&nbsp;&nbsp;<br />\n&nbsp; &nbsp; &nbsp; None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3625168","datemodified":"2021-07-25T14:21:55","file_list":["cp048591.xml","cpqsetup.exe","payload.json","setup.dll","SMKRAND5.rel"],"md5sum":"d87a444bdff88f16ec34fc442f4f815f","name":"cp048591.exe","release":"2021-07-25T14:14:04","revision":"0","sha1sum":"49785077327d36cad0066da95e08a334fc7961ad","size":"3MB","target_guids":["002340a5-4d00-3242-3030-304a46455041","002340a5-4d00-3442-3030-304a46455042"],"type_of_change":"1","version":"HPD5"}],"id":{"product":"8fa907efc8b04d69b552ce8d557c6113","version":"6f74e2e043c44b858bb247433fedb732"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB2000JFEPA and MB4000JFEPB Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB2000JFEPAおよびMB4000JFEPBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB2000JFEPA","target_guid":"002340a5-4d00-3242-3030-304a46455041","type":"sas"},{"id":"MB4000JFEPB","target_guid":"002340a5-4d00-3442-3030-304a46455042","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T10:05:15","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JFEPB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB2000JFEPA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWJNP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ND4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e50","Version":"HPD4"},{"DeviceName":"EG001200JWJNQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ND4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e51","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EG000600JWJNP and EG001200JWJNQ"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EG000600JWJNPおよびEG001200JWJNQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG000600JWJNP and EG001200JWJNQ Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"18362615","datemodified":"2021-08-30T04:08:37","file_list":["/CP048251_BUILD_2.data","/CP048251.vmexe","/CP048251.vmexe64","/CP048251.vmfile","/CP048251_VMw.zip","/CP048251.xml","/payload.json","/CP048251_VMw.zip/index.xml","/CP048251_VMw.zip/vendor-index.xml","/CP048251_VMw.zip/metadata.zip","/CP048251_VMw.zip/vib20/CP048251/HPE_bootbank_CP048251_HPD4.2-7.0.0.15843807.vib","/CP048251_VMw.zip/metadata.zip/vendor-index.xml","/CP048251_VMw.zip/metadata.zip/vmware.xml","/CP048251_VMw.zip/metadata.zip/vibs/CP048251--7897607450179728988.xml","/CP048251_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048251_HPD4.2-7.0.0.15843807.xml"],"md5sum":"c6137e820fbc9fd3185720ca1610e637","name":"CP048251.zip","release":"2021-08-30T04:02:58","revision":"0","sha1sum":"640e57fd0cb210cf58a49adab95ca439b53264c9","size":"17MB","target_guids":["452340a5-3047-3030-3630-304a574a4e50","452340a5-3047-3130-3230-304a574a4e51"],"type_of_change":"1","version":"HPD4","vib_list":[{"name":"CP048251","version":"HPD4.2-7.0.0.15843807"}]}],"id":{"product":"5829ee37bc994558baa6a98dd52b6154","version":"b899586abb884629b8c51503ec1a593b"},"installation":{"command":"CP041692.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - EG000600JWJNP and EG001200JWJNQ Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - EG000600JWJNPおよびEG001200JWJNQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG001200JWJNQ","target_guid":"452340a5-3047-3130-3230-304a574a4e51","type":"sas"},{"id":"EG000600JWJNP","target_guid":"452340a5-3047-3030-3630-304a574a4e50","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-02T06:49:37","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001200JWJNQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG000600JWJNP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB1000GVYZE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3142-3030-304756595a45","Version":"HPG4"},{"DeviceName":"MB2000GVYZF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304756595a46","Version":"HPG4"},{"DeviceName":"MB3000GVYZH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304756595a48","Version":"HPG4"},{"DeviceName":"MB4000GVYZK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304756595a4b","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB1000GVYZE, MB2000GVYZF, MB3000GVYZH, and MB4000GVYZK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) -&nbsp;MB1000GVYZE, MB2000GVYZF, MB3000GVYZH&nbsp;and MB4000GVYZK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3414744","datemodified":"2021-07-25T12:51:55","file_list":["cp048568.xml","cpqsetup.exe","payload.json","setup.dll","SMBPNTG4.rel"],"md5sum":"dfcf7cbd6ff7d81f137e1510c8d76528","name":"cp048568.exe","release":"2021-07-25T12:44:06","revision":"0","sha1sum":"77016506a76f383e82c5aa2d9cae2a42fd4486ac","size":"3MB","target_guids":["002340a5-4d00-3142-3030-304756595a45","002340a5-4d00-3242-3030-304756595a46","002340a5-4d00-3342-3030-304756595a48","002340a5-4d00-3442-3030-304756595a4b"],"type_of_change":"1","version":"HPG4"}],"id":{"product":"d905350ec9f94f94adf8077625981965","version":"c5fdf202e7b3447999585c0cb3fae9d0"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration-line: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB1000GVYZE, MB2000GVYZF, MB3000GVYZH and MB4000GVYZK Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB1000GVYZE、MB2000GVYZF、MB3000GVYZH、およびMB4000GVYZKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB1000GVYZE","target_guid":"002340a5-4d00-3142-3030-304756595a45","type":"sata"},{"id":"MB2000GVYZF","target_guid":"002340a5-4d00-3242-3030-304756595a46","type":"sata"},{"id":"MB3000GVYZH","target_guid":"002340a5-4d00-3342-3030-304756595a48","type":"sata"},{"id":"MB4000GVYZK","target_guid":"002340a5-4d00-3442-3030-304756595a4b","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T07:27:04","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB3000GVYZH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB2000GVYZF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB1000GVYZE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB4000GVYZK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]},{"key":"7800374","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"en","x_late":"This package contains utilities and libraries to enable HPE Storage fibre channel array connectivity on Red Hat Enterprise Linux 8 Server for Emulex Host Bus Adapters and Mezzanine Host Bus Adapters"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"991209","datemodified":"2021-08-26T07:47:39","file_list":["./opt/emulex/rhel8/x86_64/lib64/libdfc.so","./opt/emulex/rhel8/x86_64/lib64/libdfc.so.12","./opt/emulex/rhel8/x86_64/lib64/libdfc.so.12.8.526","./opt/emulex/rhel8/x86_64/lib64/libemsdm.so","./opt/emulex/rhel8/x86_64/lib64/libemulexhbaapi.so","./usr/lib/.build-id","./usr/lib/.build-id/be","./usr/lib/.build-id/be/cb7ea05c40554a20668a35f4fb5439d6ccd955","./usr/lib/.build-id/be/cb7ea05c40554a20668a35f4fb5439d6ccd955.1","./usr/lib/.build-id/c6","./usr/lib/.build-id/c6/793599f422ad7b0bc69185eaffaf80d457dffb","./usr/lib/.build-id/c6/793599f422ad7b0bc69185eaffaf80d457dffb.1","./usr/lib/.build-id/f5","./usr/lib/.build-id/f5/0d4d3acef5d038c3c45a59e9e47190964faff7","./usr/lib/.build-id/f5/0d4d3acef5d038c3c45a59e9e47190964faff7.1","./usr/lib64/libdfc.so","./usr/lib64/libdfc.so.12","./usr/lib64/libdfc.so.12.8.526","./usr/lib64/libemsdm.so","./usr/lib64/libemulexhbaapi.so","./usr/share/smartupdate/HPE-CNA-FC-Emulex-Enablement-Kit/component.xml"],"md5sum":"c95a6c1fa79be9721f79a37956e4b19d","name":"HPE-CNA-FC-Emulex-Enablement-Kit-12.8.526.0-1.rhel8.x86_64.rpm","release":"2021-08-26T07:37:04","revision":"0","sha1sum":"07ebcd97cdc25e44898be551fa372e7bf25de9f1","size":"967KB","target_guids":[],"type_of_change":"0","version":"12.8.526.0"}],"id":{"product":"dbaf045824f946fba17075265a596464","version":"b4b1a2a1f0f24234bacd55d1e434ef96"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The target environment must have the libHBAAPI Package installed prior to the installation of the enablement kit. (If not already present, the libHBAAPI Package can be obtained from the operating system installation media.)</p>\n\n<p>This version of the enablement kit does not provide the additional functionality of rebuilding the ram disk or setting driver parameters as the previous versions had done.&nbsp; Please refer to the &ldquo;Additional setup&rdquo; section of the Native Linux Device-Mapper Multipath for HPE StorageWorks Arrays reference guide for instructions on how to perform these functions.&nbsp; The reference guide is available at the following link:</p>\n\n<p><a href=\"http://www.hpe.com/storage/spock/\">http://www.hpe.com/storage/spock/</a></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex Fibre Channel Enablement Kit for Host Bus Adapters and Mezzanine Host Bus Adapters for Red Hat Enterprise Linux 8 Server"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"F100","subven":"10DF","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T10:35:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added the following support:</p>\n\n<ul>\n\t<li>Added support for RHEL 8.4</li>\n</ul>\n\n<p>Updated to version 12.8.526.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"HPE-CNA-FC-Emulex-Enablement-Kit","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEe0HPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e4c","Version":"HPD4"},{"DeviceName":"EG002400JWJNN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEe0HPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e4e","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EG001800JWJNL and EG002400JWJNN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG001800JWJNL and EG002400JWJNN Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp; </strong>None</p>\n"}],"files":[{"bytes":"16182523","datemodified":"2021-08-27T18:58:52","file_list":["/CP049141_BUILD_1.data","/CP049141.vmexe","/CP049141.vmexe64","/CP049141.vmfile","/CP049141_VMw.zip","/CP049141.xml","/payload.json","/CP049141_VMw.zip/index.xml","/CP049141_VMw.zip/vendor-index.xml","/CP049141_VMw.zip/metadata.zip","/CP049141_VMw.zip/vib20/CP049141/HPE_bootbank_CP049141_HPD4.1-7.0.0.15843807.vib","/CP049141_VMw.zip/metadata.zip/vendor-index.xml","/CP049141_VMw.zip/metadata.zip/vmware.xml","/CP049141_VMw.zip/metadata.zip/vibs/CP049141--5639765293202828470.xml","/CP049141_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049141_HPD4.1-7.0.0.15843807.xml"],"md5sum":"3d00b14caf751009ea3dde3fcf4be07a","name":"CP049141.zip","release":"2021-08-27T18:53:54","revision":"0","sha1sum":"f397be9dc29f62179e9ea77d4606f9720185a333","size":"15MB","target_guids":["452340a5-3047-3130-3830-304a574a4e4c","452340a5-3047-3230-3430-304a574a4e4e"],"type_of_change":"1","version":"HPD4","vib_list":[{"name":"CP049141","version":"HPD4.1-7.0.0.15843807"}]}],"id":{"product":"d1014161143144dea5631e9b65f9f0d4","version":"3d6d9815f0e54c68bfe79bd573c48f1d"},"installation":{"command":"CP041560.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>HP Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします。</li>\n\t<li>CPXXXXXX.vmexe(ESXi 6.7 &以前のバージョン)およびCPXXXXXX.vmexe64(ESXi 7.0)は、次のコマンドを使用して実行可能です:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod x CPXXXXXX.vmexe    または    chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPXXXXXX.vmexe(または)./CPXXXXXX.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EG001800JWJNL and EG002400JWJNN Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG002400JWJNN","target_guid":"452340a5-3047-3230-3430-304a574a4e4e","type":"sas"},{"id":"EG001800JWJNL","target_guid":"452340a5-3047-3130-3830-304a574a4e4c","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T19:01:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This firmware fixes a potential reliability condition, a rare data integrity issue and the cause of a potential hang.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001800JWJNL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG002400JWJNN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCD6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c38303047","Version":"GPK3"},{"DeviceName":"KCD6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c31543630","Version":"GPK3"},{"DeviceName":"KCD6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c33543230","Version":"GPK3"},{"DeviceName":"KCD6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c36543430","Version":"GPK3"},{"DeviceName":"KCD6XVUL12T8","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c31325438","Version":"GPK3"},{"DeviceName":"KCD6XLUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c39363047","Version":"GPK3"},{"DeviceName":"KCD6XLUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c31543932","Version":"GPK3"},{"DeviceName":"KCD6XLUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c33543834","Version":"GPK3"},{"DeviceName":"KCD6XLUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c37543638","Version":"GPK3"},{"DeviceName":"KCD6XLUL15T3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c31355433","Version":"GPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3"},{"lang":"ja","x_late":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: KCD6XVUL800G、KCD6XVUL1T60、KCD6XVUL3T20、KCD6XVUL6T40、KCD6XVUL12T8、KCD6XLUL960G、KCD6XLUL1T92、KCD6XLUL3T84、KCD6XLUL7T68、KCD6XLUL15T3"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows&nbsp;(x64) - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3&nbsp; Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK3</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"4140472","datemodified":"2021-08-16T10:59:19","file_list":["cp049282.xml","cpqsetup.exe","payload.json","setup.dll","TACD6ALLGPK3.rel"],"md5sum":"f977c0218aaa038897261b6851b2fd71","name":"cp049282.exe","release":"2021-08-16T10:51:04","revision":"0","sha1sum":"230604df1654239b734f2ec7a1fa5e9847265130","size":"3MB","target_guids":["002340a5-434b-3644-5856-554c38303047","002340a5-434b-3644-5856-554c31543630","002340a5-434b-3644-5856-554c33543230","002340a5-434b-3644-5856-554c36543430","002340a5-434b-3644-5856-554c31325438","002340a5-434b-3644-584c-554c39363047","002340a5-434b-3644-584c-554c31543932","002340a5-434b-3644-584c-554c33543834","002340a5-434b-3644-584c-554c37543638","002340a5-434b-3644-584c-554c31355433"],"type_of_change":"1","version":"GPK3"}],"id":{"product":"b0d91a06dd9c4473a208b93b1c088e41","version":"e8e976885c88449a9c03c7203a6afe4d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには</strong><a href=\"http://www.hpe.com/jp/servers/spp_dl\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3 Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - KCD6XVUL800G、KCD6XVUL1T60、KCD6XVUL3T20、KCD6XVUL6T40、KCD6XVUL12T8、KCD6XLUL960G、KCD6XLUL1T92、KCD6XLUL3T84、KCD6XLUL7T68、KCD6XLUL15T3ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"KCD6XLUL7T68","target_guid":"002340a5-434b-3644-584c-554c37543638","type":"nvme"},{"id":"KCD6XVUL6T40","target_guid":"002340a5-434b-3644-5856-554c36543430","type":"nvme"},{"id":"KCD6XVUL1T60","target_guid":"002340a5-434b-3644-5856-554c31543630","type":"nvme"},{"id":"KCD6XVUL800G","target_guid":"002340a5-434b-3644-5856-554c38303047","type":"nvme"},{"id":"KCD6XVUL3T20","target_guid":"002340a5-434b-3644-5856-554c33543230","type":"nvme"},{"id":"KCD6XVUL12T8","target_guid":"002340a5-434b-3644-5856-554c31325438","type":"nvme"},{"id":"KCD6XLUL960G","target_guid":"002340a5-434b-3644-584c-554c39363047","type":"nvme"},{"id":"KCD6XLUL1T92","target_guid":"002340a5-434b-3644-584c-554c31543932","type":"nvme"},{"id":"KCD6XLUL3T84","target_guid":"002340a5-434b-3644-584c-554c33543834","type":"nvme"},{"id":"KCD6XLUL15T3","target_guid":"002340a5-434b-3644-584c-554c31355433","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-16T10:43:23","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This Firmware release address below&nbsp;fixes and additional features:</p>\n\n<ul>\n\t<li>FW Transfer Fix</li>\n\t<li>Drive Failure Fix</li>\n\t<li>Power Loss Protection</li>\n\t<li>FW Download Fix</li>\n\t<li>Reset Fix</li>\n\t<li>Shutdown fix</li>\n\t<li>PCIe Improvement</li>\n\t<li>Random Write Improvement</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"KCD6XVUL800G","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XLUL7T68","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XLUL3T84","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XLUL960G","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XVUL12T8","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XLUL15T3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XVUL6T40","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XVUL3T20","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XVUL1T60","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XLUL1T92","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWFVC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SEhD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3830-304a57465643","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: EG001800JWFVC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG001800JWFVC Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp;&nbsp; </strong>None</p>\n"}],"files":[{"bytes":"4892540","datemodified":"2021-07-23T08:32:58","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-693b9a2853-HPD4-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-693b9a2853-HPD4-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-693b9a2853-HPD4-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-693b9a2853-HPD4-2.1/CP048066.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-693b9a2853-HPD4-2.1/T14SEhD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-693b9a2853-HPD4-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-693b9a2853-HPD4-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-693b9a2853-HPD4-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-693b9a2853-HPD4-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048066.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048066.scexe"],"md5sum":"b5205e45ca0d9e3032c565d23c5289d7","name":"firmware-hdd-693b9a2853-HPD4-2.1.x86_64.rpm","release":"2021-07-23T08:20:04","revision":"0","sha1sum":"03639e5da2957c3e9839c4830c2042e2f264aaed","size":"4MB","target_guids":["452340a5-3047-3130-3830-304a57465643"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"4dae182fcdec4e4aa31d1ea079120a60","version":"afadc2f4e7af45849d4c2127ad7df913"},"installation":{"command":"CP040349.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://www.hp.com/swpublishing/MTX-357c87ee9b054ad7a631d9eaba\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EG001800JWFVC Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - EG001800JWFVCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EG001800JWFVC","target_guid":"452340a5-3047-3130-3830-304a57465643","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-21T11:48:16","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>A low-probability, high severity corner case of sustained outer-diameter activity with emergency power off when heads are at the outer diameter prevented heads from parking/latching properly on a few drives in the field.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001800JWFVC","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel and Mezzanine Host Bus Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"583106","datemodified":"2021-08-26T08:40:45","file_list":["./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/lpfc.ko","./usr/share/smartupdate/elx-lpfc-kmp-default/component.xml"],"md5sum":"478c0cc0870980b01953c939d2f61373","name":"elx-lpfc-kmp-default-12.8.528.7_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-08-26T08:34:04","revision":"0","sha1sum":"65df195fb2d63be3e23c6496161d250f2dcc7775","size":"569KB","target_guids":[],"type_of_change":"1","version":"12.8.528.7"}],"id":{"product":"5dd37edfaffe4ea2b5c079c4765ff51b","version":"4cd1925380874ff89161a66d14d042b5"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh elx-lpfc-kmp-default-12.8.509.3_k5.3.18_51-1.sles15sp3.x86_64.rpm</p>\n\n<p>4.When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>\n\n<p>Rewrite of same Driver version has to be performed using &ndash;force or --replacepkgs with --nodeps option</p>\n\n<p>Example: rpm &ndash;Uvh elx-lpfc-kmp-default-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm &ndash;force --nodeps</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; rpm &ndash;Uvh elx-lpfc-kmp-default-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm &ndash;replacepkgs --nodeps</p>\n\n<p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"SUSE Linux Enterprise Server 12 Service Pack 5 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters and Mezzanine Host Bus Adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"F100","subven":"10DF","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T10:36:15","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to driver version 12.8.528.7</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"elx-lpfc-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCM6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5856-554c38303047","Version":"GPK3"},{"DeviceName":"KCM6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5856-554c31543630","Version":"GPK3"},{"DeviceName":"KCM6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5856-554c33543230","Version":"GPK3"},{"DeviceName":"KCM6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5856-554c36543430","Version":"GPK3"},{"DeviceName":"KCM6XRUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5852-554c39363047","Version":"GPK3"},{"DeviceName":"KCM6XRUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5852-554c31543932","Version":"GPK3"},{"DeviceName":"KCM6XRUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5852-554c33543834","Version":"GPK3"},{"DeviceName":"KCM6XRUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5852-554c37543638","Version":"GPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68"},{"lang":"ja","x_late":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: KCM6XVUL800G、KCM6XVUL1T60、KCM6XVUL3T20、KCM6XVUL6T40、KCM6XRUL960G、KCM6XRUL1T92、KCM6XRUL3T84、KCM6XRUL7T68"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows&nbsp;(x64) - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68&nbsp; Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK3</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"4148688","datemodified":"2021-08-16T11:47:36","file_list":["cp049285.xml","cpqsetup.exe","payload.json","setup.dll","TACM6ALLGPK3.rel"],"md5sum":"ea23a72233b293e36e748b6ae241e145","name":"cp049285.exe","release":"2021-08-16T11:38:27","revision":"0","sha1sum":"33b15a80d2835e31c30c1c3c16147060f0241d59","size":"3MB","target_guids":["002340a5-434b-364d-5856-554c38303047","002340a5-434b-364d-5856-554c31543630","002340a5-434b-364d-5856-554c33543230","002340a5-434b-364d-5856-554c36543430","002340a5-434b-364d-5852-554c39363047","002340a5-434b-364d-5852-554c31543932","002340a5-434b-364d-5852-554c33543834","002340a5-434b-364d-5852-554c37543638"],"type_of_change":"1","version":"GPK3"}],"id":{"product":"ffbc55840f92498790e9569c6abb14d8","version":"ba5632b2c2b346dcb550c249a320af33"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには</strong><a href=\"http://www.hpe.com/jp/servers/spp_dl\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68 Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - KCM6XVUL800G、KCM6XVUL1T60、KCM6XVUL3T20、KCM6XVUL6T40、KCM6XRUL960G、KCM6XRUL1T92、KCM6XRUL3T84、KCM6XRUL7T68ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"KCM6XRUL960G","target_guid":"002340a5-434b-364d-5852-554c39363047","type":"nvme"},{"id":"KCM6XRUL7T68","target_guid":"002340a5-434b-364d-5852-554c37543638","type":"nvme"},{"id":"KCM6XRUL1T92","target_guid":"002340a5-434b-364d-5852-554c31543932","type":"nvme"},{"id":"KCM6XVUL3T20","target_guid":"002340a5-434b-364d-5856-554c33543230","type":"nvme"},{"id":"KCM6XRUL3T84","target_guid":"002340a5-434b-364d-5852-554c33543834","type":"nvme"},{"id":"KCM6XVUL800G","target_guid":"002340a5-434b-364d-5856-554c38303047","type":"nvme"},{"id":"KCM6XVUL6T40","target_guid":"002340a5-434b-364d-5856-554c36543430","type":"nvme"},{"id":"KCM6XVUL1T60","target_guid":"002340a5-434b-364d-5856-554c31543630","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-16T11:27:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This Firmware release address below&nbsp;fixes and additional features:</p>\n\n<ul>\n\t<li>FW Transfer Fix</li>\n\t<li>Drive Failure Fix</li>\n\t<li>Power Loss Protection</li>\n\t<li>FW Download Fix</li>\n\t<li>Reset Fix</li>\n\t<li>Shutdown fix</li>\n\t<li>PCIe Improvement</li>\n\t<li>Random Write Improvement</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"KCM6XVUL6T40","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCM6XRUL1T92","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCM6XVUL800G","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCM6XVUL3T20","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCM6XRUL3T84","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCM6XVUL1T60","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCM6XRUL960G","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCM6XRUL7T68","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB002000JWFVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATRsnSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a5746564e","Version":"HPD4"},{"DeviceName":"MB004000JWFVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATRsnSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a57465650","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB002000JWFVN and MB004000JWFVP"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB002000JWFVN and MB004000JWFVP&nbsp;Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"4891151","datemodified":"2021-07-23T08:07:28","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-d7af557f47-HPD4-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-d7af557f47-HPD4-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-d7af557f47-HPD4-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d7af557f47-HPD4-2.1/CP048097.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-d7af557f47-HPD4-2.1/TATCATRsnSD4.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-d7af557f47-HPD4-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d7af557f47-HPD4-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-d7af557f47-HPD4-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-d7af557f47-HPD4-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048097.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048097.scexe"],"md5sum":"a5f0ec10d093c5076c6a1a67621f90f0","name":"firmware-hdd-d7af557f47-HPD4-2.1.x86_64.rpm","release":"2021-07-23T07:54:07","revision":"0","sha1sum":"7fd94b760930ba104f945014e32a737472aac292","size":"4MB","target_guids":["4d2340a5-3042-3230-3030-304a5746564e","4d2340a5-3042-3430-3030-304a57465650"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"f1e144df7ff3445292cda5ea1ed9d30c","version":"cbb50abb426344279a81c407c3d58469"},"installation":{"command":"CP041753.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/jp/servers/spp_dl\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64)  - MB002000JWFVN and MB004000JWFVP Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB002000JWFVNおよびMB004000JWFVP ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB002000JWFVN","target_guid":"4d2340a5-3042-3230-3030-304a5746564e","type":"sas"},{"id":"MB004000JWFVP","target_guid":"4d2340a5-3042-3430-3030-304a57465650","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T12:44:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware provides a change to the Vendor ID in the VPD page that refers to HP instead of HPE.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB002000JWFVN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB004000JWFVP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GXAWE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304758415745","Version":"HPG1"},{"DeviceName":"VK000480GXAWK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-30475841574b","Version":"HPG1"},{"DeviceName":"VK000960GXAWL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-30475841574c","Version":"HPG1"},{"DeviceName":"VK001920GXAWN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-30475841574e","Version":"HPG1"},{"DeviceName":"VK003840GXAWP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304758415750","Version":"HPG1"},{"DeviceName":"VK007680GXAWQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-304758415751","Version":"HPG1"},{"DeviceName":"MK000480GXAWF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304758415746","Version":"HPG1"},{"DeviceName":"MK000960GXAXB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304758415842","Version":"HPG1"},{"DeviceName":"MK001920GXAWR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304758415752","Version":"HPG1"},{"DeviceName":"MK003840GXAWT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-304758415754","Version":"HPG1"},{"DeviceName":"VR000240GXBBL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3234-30475842424c","Version":"HPG1"},{"DeviceName":"MR000480GXBGH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3438-304758424748","Version":"HPG1"},{"DeviceName":"MR000960GXBGK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3936-30475842474b","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000240GXAWE, VK000480GXAWK, VK000960GXAWL, VK001920GXAWN, VK003840GXAWP, VK007680GXAWQ, MK000480GXAWF, MK000960GXAXB,MK001920GXAWR, MK003840GXAWT, VR000240GXBBL, MR000480GXBGH and MR000960GXBGK"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000240GXAWE、VK000480GXAWK、VK000960GXAWL、VK001920GXAWN、VK003840GXAWP、VK007680GXAWQ、MK000480GXAWF、MK000960GXAXB、MK001920GXAWR、MK003840GXAWT、VR000240GXBBL、MR000480GXBGH、およびMR000960GXBGK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;VK000240GXAWE, VK000480GXAWK, VK000960GXAWL, VK001920GXAWN, VK003840GXAWP, VK007680GXAWQ, MK000480GXAWF, MK000960GXAXB,MK001920GXAWR, MK003840GXAWT, VR000240GXBBL, MR000480GXBGH and MR000960GXBGK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"19771634","datemodified":"2021-08-30T05:11:10","file_list":["/CP049160_BUILD_2.data","/CP049160.vmexe","/CP049160.vmexe64","/CP049160.vmfile","/CP049160_VMw.zip","/CP049160.xml","/payload.json","/CP049160_VMw.zip/index.xml","/CP049160_VMw.zip/vendor-index.xml","/CP049160_VMw.zip/metadata.zip","/CP049160_VMw.zip/vib20/CP049160/HPE_bootbank_CP049160_HPG1.2-7.0.0.15843807.vib","/CP049160_VMw.zip/metadata.zip/vendor-index.xml","/CP049160_VMw.zip/metadata.zip/vmware.xml","/CP049160_VMw.zip/metadata.zip/vibs/CP049160--7393442737713041868.xml","/CP049160_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049160_HPG1.2-7.0.0.15843807.xml"],"md5sum":"45cd0e36ca4f7df9dd878fab042a52c5","name":"CP049160.zip","release":"2021-08-30T05:06:15","revision":"0","sha1sum":"744b3f04591cd26673cf31b6beb195846a2f1a4a","size":"18MB","target_guids":["562340a5-304b-3030-3234-304758415745","562340a5-304b-3030-3438-30475841574b","562340a5-304b-3030-3936-30475841574c","562340a5-304b-3130-3932-30475841574e","562340a5-304b-3330-3834-304758415750","562340a5-304b-3730-3638-304758415751","4d2340a5-304b-3030-3438-304758415746","4d2340a5-304b-3030-3936-304758415842","4d2340a5-304b-3130-3932-304758415752","4d2340a5-304b-3330-3834-304758415754","562340a5-3052-3030-3234-30475842424c","4d2340a5-3052-3030-3438-304758424748","4d2340a5-3052-3030-3936-30475842474b"],"type_of_change":"1","version":"HPG1","vib_list":[{"name":"CP049160","version":"HPG1.2-7.0.0.15843807"}]}],"id":{"product":"2f7da3629806488ebbb800b74a44db9d","version":"25f43da49b724c95982004c2de170ae8"},"installation":{"command":"CP043256.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>HP Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK000240GXAWE, VK000480GXAWK, VK000960GXAWL, VK001920GXAWN, VK003840GXAWP, VK007680GXAWQ, MK000480GXAWF, MK000960GXAXB,MK001920GXAWR, MK003840GXAWT, VR000240GXBBL, MR000480GXBGH and MR000960GXBGK Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VK000240GXAWE、VK000480GXAWK、VK000960GXAWL、VK001920GXAWN、VK003840GXAWP、VK007680GXAWQ、MK000480GXAWF、MK000960GXAXB、MK001920GXAWR、MK003840GXAWT、VR000240GXBBL、MR000480GXBGH、およびMR000960GXBGKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VK000240GXAWE","target_guid":"562340a5-304b-3030-3234-304758415745","type":"sata"},{"id":"VK000480GXAWK","target_guid":"562340a5-304b-3030-3438-30475841574b","type":"sata"},{"id":"VK000960GXAWL","target_guid":"562340a5-304b-3030-3936-30475841574c","type":"sata"},{"id":"VK003840GXAWP","target_guid":"562340a5-304b-3330-3834-304758415750","type":"sata"},{"id":"VK007680GXAWQ","target_guid":"562340a5-304b-3730-3638-304758415751","type":"sata"},{"id":"MK000480GXAWF","target_guid":"4d2340a5-304b-3030-3438-304758415746","type":"sata"},{"id":"MK000960GXAXB","target_guid":"4d2340a5-304b-3030-3936-304758415842","type":"sata"},{"id":"MK001920GXAWR","target_guid":"4d2340a5-304b-3130-3932-304758415752","type":"sata"},{"id":"MK003840GXAWT","target_guid":"4d2340a5-304b-3330-3834-304758415754","type":"sata"},{"id":"VR000240GXBBL","target_guid":"562340a5-3052-3030-3234-30475842424c","type":"sata"},{"id":"MR000480GXBGH","target_guid":"4d2340a5-3052-3030-3438-304758424748","type":"sata"},{"id":"MR000960GXBGK","target_guid":"4d2340a5-3052-3030-3936-30475842474b","type":"sata"},{"id":"VK001920GXAWN","target_guid":"562340a5-304b-3130-3932-30475841574e","type":"sata"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-27T15:47:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>The updates were included in a regularly scheduled 5300 maintenance release. This firmware has a security version upgrade to include TCGe SKUs and prevent a downloading of a back level firmware version of HPG0 after upgrading to HPG1.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK001920GXAWR","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK003840GXAWT","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VR000240GXBBL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GXAWP","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MR000960GXBGK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GXAWK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GXAXB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GXAWE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GXAWL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GXAWN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK007680GXAWQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GXAWF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MR000480GXBGH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO0480JFDGT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304f-3438-304a46444754","Version":"HPD9"},{"DeviceName":"VO0960JFDGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304f-3936-304a46444755","Version":"HPD9"},{"DeviceName":"VO1920JFDGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314f-3932-304a46444756","Version":"HPD9"},{"DeviceName":"VO3840JFDHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-334f-3834-304a46444841","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO0480JFDGT, VO0960JFDGU, VO1920JFDGV, and VO3840JFDHA Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： VO0480JFDGT、VO0960JFDGU、VO1920JFDGVおよびVO3840JFDHAドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VO0480JFDGT, VO0960JFDGU, VO1920JFDGV&nbsp;and VO3840JFDHA Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD9</p>\n\n<p><strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD8</p>\n\n<p><strong>Previous Version of Firmware:<br />\n&nbsp; &nbsp;</strong> &nbsp; HPD8</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"5060702","datemodified":"2021-07-23T09:34:34","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8ed8893abd-HPD9-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8ed8893abd-HPD9-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8ed8893abd-HPD9-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8ed8893abd-HPD9-4.1/CP048207.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8ed8893abd-HPD9-4.1/GP1633D9.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8ed8893abd-HPD9-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8ed8893abd-HPD9-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8ed8893abd-HPD9-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8ed8893abd-HPD9-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048207.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048207.scexe"],"md5sum":"b95ff5cd5171827f8d4a3531dce0cfeb","name":"firmware-hdd-8ed8893abd-HPD9-4.1.x86_64.rpm","release":"2021-07-23T09:19:09","revision":"0","sha1sum":"0dadfc437633b3b5a2151438a56fec66fd4bfa51","size":"4MB","target_guids":["002340a5-5600-304f-3438-304a46444754","002340a5-5600-304f-3936-304a46444755","002340a5-5600-314f-3932-304a46444756","002340a5-5600-334f-3834-304a46444841"],"type_of_change":"1","version":"HPD9"}],"id":{"product":"13652737a6ea4ec4a4913fd807c0a85c","version":"bb7240a85785410f8b886ab52d751b4a"},"installation":{"command":"CP042220.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VO0480JFDGT, VO0960JFDGU, VO1920JFDGV and VO3840JFDHA Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VO0480JFDGT、VO0960JFDGU、VO1920JFDGV、およびVO3840JFDHAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VO3840JFDHA","target_guid":"002340a5-5600-334f-3834-304a46444841","type":"sas"},{"id":"VO1920JFDGV","target_guid":"002340a5-5600-314f-3932-304a46444756","type":"sas"},{"id":"VO0480JFDGT","target_guid":"002340a5-5600-304f-3438-304a46444754","type":"sas"},{"id":"VO0960JFDGU","target_guid":"002340a5-5600-304f-3936-304a46444755","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T11:38:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO0960JFDGU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO0480JFDGT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO3840JFDHA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO1920JFDGV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWWQP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNESD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57575150","Version":"HPD6"},{"DeviceName":"MB006000JWWQN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNESD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a5757514e","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB008000JWWQP and MB006000JWWQN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB008000JWWQP and MB006000JWWQN Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD2</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"18324220","datemodified":"2021-08-27T11:41:18","file_list":["/CP048426_BUILD_2.data","/CP048426.vmexe","/CP048426.vmexe64","/CP048426.vmfile","/CP048426_VMw.zip","/CP048426.xml","/payload.json","/CP048426_VMw.zip/index.xml","/CP048426_VMw.zip/vendor-index.xml","/CP048426_VMw.zip/metadata.zip","/CP048426_VMw.zip/vib20/CP048426/HPE_bootbank_CP048426_HPD6.2-7.0.0.15843807.vib","/CP048426_VMw.zip/metadata.zip/vendor-index.xml","/CP048426_VMw.zip/metadata.zip/vmware.xml","/CP048426_VMw.zip/metadata.zip/vibs/CP048426-2406326352364881006.xml","/CP048426_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048426_HPD6.2-7.0.0.15843807.xml"],"md5sum":"dbc67d3ed9a18075f2a574f2544c76a6","name":"CP048426.zip","release":"2021-08-27T11:35:58","revision":"0","sha1sum":"af350f596b8a3506bfea0779bffc2699c92c41b3","size":"17MB","target_guids":["4d2340a5-3042-3830-3030-304a57575150","4d2340a5-3042-3630-3030-304a5757514e"],"type_of_change":"1","version":"HPD6","vib_list":[{"name":"CP048426","version":"HPD6.2-7.0.0.15843807"}]}],"id":{"product":"386eb9df6414454ca63bfe17b21ac760","version":"1ee138f5765c41c49519ba9fed6f5d4f"},"installation":{"command":"CP043259.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB008000JWWQP and MB006000JWWQN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor ESXi - MB008000JWWQPおよびMB006000JWWQNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB006000JWWQN","target_guid":"4d2340a5-3042-3630-3030-304a5757514e","type":"sas"},{"id":"MB008000JWWQP","target_guid":"4d2340a5-3042-3830-3030-304a57575150","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-10T06:58:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000JWWQP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB006000JWWQN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel and Blade Storage Mezzanine Fibre Channel over Ethernet Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"426514","datemodified":"2021-08-27T06:16:25","file_list":["./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/brcmfcoe.ko","./usr/share/smartupdate/brcmfcoe-kmp-default/component.xml"],"md5sum":"9f935d631c5d7e9db18ffe642670364e","name":"brcmfcoe-kmp-default-12.0.1342.0_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-08-27T06:08:08","revision":"0","sha1sum":"97c6be577b52cf7a34a98a7a72a8f11e34bf6b75","size":"416KB","target_guids":[],"type_of_change":"1","version":"12.0.1342.0"}],"id":{"product":"72cec73acda24223802904384c226c48","version":"baca44904b0141ed89723a3f84a4ad5f"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh brcmfcoe-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh brcmfcoe-kmp-default-11.2.xxxx.x_3.0.76._0.11-1.sles11sp3.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete, the following message displays:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e brcmfcoe-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"SUSE Linux Enterprise Server 15 service pack 2 Fibre Channel over Ethernet (FCoE) Driver Kit for HPE Storage Emulex(BRCM) Converged Network Adapters and mezzanine Converged Network Adapters(CNAs)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T11:00:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to Driver version 12.0.1342.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"}],"sw_keys":[{"name":"brcmfcoe-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains iSCSI drivers for the HPE Emulex 10/20GbE Server Adapters running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Emulex 10/20GbEサーバーアダプター用のiSCSIドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1050369","datemodified":"2021-01-14T08:12:01","file_list":["./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/be2iscsi","./lib/modules/5.3.18-22-default/updates/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/be2iscsi-kmp-default/component.xml"],"md5sum":"391cf277e9181d32d7c8c88c1fb70587","name":"be2iscsi-kmp-default-12.0.1342.0_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-01-14T07:49:05","revision":"0","sha1sum":"f4c69b955262ad19c50484d5be2e4cd9291156ae","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecdaa9949b"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"978624","datemodified":"2021-01-14T07:58:20","file_list":["./lib/modules/4.12.14-195-default","./lib/modules/4.12.14-195-default/updates","./lib/modules/4.12.14-195-default/updates/be2iscsi","./lib/modules/4.12.14-195-default/updates/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/be2iscsi-kmp-default/component.xml"],"md5sum":"2f7e5d427d02ae9abf84cc0848984d27","name":"be2iscsi-kmp-default-12.0.1342.0_k4.12.14_195-1.sles15sp1.x86_64.rpm","release":"2021-01-14T07:49:05","revision":"0","sha1sum":"8039e9e645120611d5084ceeaa12336dd4d1180b","size":"955KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecdaa9949b"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"dd5b092a7dec4d3e9ecd257e4f87af47","version":"90e50c8ec51142778ad28c7f963aff19"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Emulex 10/20GbE iSCSI Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE Emulex 10/20GbE iSCSI ドライバー for SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0728","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c8144","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c21d4","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072215908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c220a","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 15 Service Pack 1 and&nbsp;SUSE Linux Enterprise Server 15 Service Pack 2</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"be2iscsi-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2iscsi-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2iscsi-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2iscsi-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox adapter cards."},{"lang":"ja","x_late":"このRPMには、サポートされているHPE Mellanoxアダプターカード用のHPEによるテストと承認済みのLinuxベースMellanox RoCE (RDMA over Converged Ethernet)ドライバーが含まれます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1694911","datemodified":"2021-05-17T18:59:12","file_list":["./etc/depmod.d/zz01-mlnx-ofa_kernel-bnxt_re.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-efa.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-hfi1.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-i40iw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ipath.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ipoib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_iser.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_isert.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_mthca.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_qib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srp.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srpt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_umad.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_uverbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cxgb3.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cxgb4.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_nes.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_en.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_fpga_tools.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx_compat.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxfw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvme-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvmet-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ocrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-opa_vnic.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-qedr.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_rxe.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdmavt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rpcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-svcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-usnic_verbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-vmw_pvrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-xprtrdma.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/compat","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/compat/mlx_compat.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_cm.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_core.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_ucm.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_umad.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/iw_cm.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_cm.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb3","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb3/iw_cxgb3.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa/efa.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/i40iw","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ipath","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ipath/ib_ipath.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mthca","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mthca/ib_mthca.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/nes","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/nes/iw_nes.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ocrdma","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ocrdma/ocrdma.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qib","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qib/ib_qib.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx4","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx4/mlx4_core.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx4/mlx4_en.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/fpga","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/fpga/mlx5_fpga_tools.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host/nvme-rdma.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/net","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/kmod-mlnx-ofa_kernel/component.xml"],"md5sum":"751d7878aad64a72f7380978e7996d3c","name":"kmod-mlnx-ofa_kernel-4.9-OFED.4.9.3.1.6.1.rhel7u8.x86_64.rpm","release":"2021-05-17T17:34:05","revision":"0","sha1sum":"66a3e2bb736e6a059706026199a57ac6e59c559e","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"4.9"},{"bytes":"2257620","datemodified":"2021-05-17T19:01:56","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/connectx.conf","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d/mlx4.driver","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/security/limits.d/30-libvma-limits.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/82-net-setup-link.rules","./etc/udev/rules.d/90-ib.rules","./sbin/connectx_port_config","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/ibdev2netdev","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_get_vfs.pl","./usr/bin/mlnx_perf","./usr/bin/mlnx_qcn","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/lib/python2.7/site-packages/dcbnetlink.py","./usr/lib/python2.7/site-packages/genetlink.py","./usr/lib/python2.7/site-packages/netlink.py","./usr/lib/python2.7/site-packages/ofed_le_utils-1.0.3-py2.7.egg-info","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/vma.service","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.0","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.0.0","./usr/lib64/libmlx4-rdmav2.so","./usr/lib64/libmlx5-rdmav2.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.0.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.0.0","./usr/lib64/libvma-debug.so","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.0.2","./usr/lib64/mlnx_ofed/valgrind/libibverbs.so.1","./usr/lib64/mlnx_ofed/valgrind/libibverbs.so.1.0.0","./usr/lib64/mlnx_ofed/valgrind/libmlx4-rdmav2.so","./usr/lib64/mlnx_ofed/valgrind/libmlx4.so","./usr/lib64/mlnx_ofed/valgrind/libmlx5-rdmav2.so","./usr/lib64/mlnx_ofed/valgrind/libmlx5.so.1","./usr/lib64/mlnx_ofed/valgrind/libmlx5.so.1.0.0","./usr/lib64/mlnx_ofed/valgrind/librdmacm.so.1","./usr/lib64/mlnx_ofed/valgrind/librdmacm.so.1.0.0","./usr/lib64/mlnx_ofed/valgrind/rsocket/librspreload.so.1","./usr/lib64/mlnx_ofed/valgrind/rsocket/librspreload.so.1.0.0","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vma","./usr/sbin/vmad","./usr/share/doc/ib2ib","./usr/share/doc/ib2ib/README","./usr/share/doc/libibumad-43.1.1.MLNX20200211.078947f","./usr/share/doc/libibumad-43.1.1.MLNX20200211.078947f/AUTHORS","./usr/share/doc/libibumad-43.1.1.MLNX20200211.078947f/COPYING","./usr/share/doc/libibumad-43.1.1.MLNX20200211.078947f/ChangeLog","./usr/share/doc/libibverbs-41mlnx1","./usr/share/doc/libibverbs-41mlnx1/AUTHORS","./usr/share/doc/libibverbs-41mlnx1/COPYING","./usr/share/doc/libibverbs-41mlnx1/ChangeLog","./usr/share/doc/libibverbs-41mlnx1/README","./usr/share/doc/libmlx4-41mlnx1","./usr/share/doc/libmlx4-41mlnx1/AUTHORS","./usr/share/doc/libmlx4-41mlnx1/COPYING","./usr/share/doc/libmlx4-41mlnx1/README","./usr/share/doc/libmlx5-41mlnx1","./usr/share/doc/libmlx5-41mlnx1/AUTHORS","./usr/share/doc/libmlx5-41mlnx1/COPYING","./usr/share/doc/libmlx5-41mlnx1/README","./usr/share/doc/librdmacm-41mlnx1","./usr/share/doc/librdmacm-41mlnx1/AUTHORS","./usr/share/doc/librdmacm-41mlnx1/COPYING","./usr/share/doc/librdmacm-41mlnx1/README","./usr/share/doc/libvma-9.0.2/README.txt","./usr/share/doc/libvma-9.0.2/VMA_VERSION","./usr/share/doc/libvma-9.0.2/journal.txt","./usr/share/man/man3/umad_addr_dump.3.gz","./usr/share/man/man3/umad_alloc.3.gz","./usr/share/man/man3/umad_attribute_str.3.gz","./usr/share/man/man3/umad_class_str.3.gz","./usr/share/man/man3/umad_close_port.3.gz","./usr/share/man/man3/umad_debug.3.gz","./usr/share/man/man3/umad_done.3.gz","./usr/share/man/man3/umad_dump.3.gz","./usr/share/man/man3/umad_free.3.gz","./usr/share/man/man3/umad_free_ca_namelist.3.gz","./usr/share/man/man3/umad_get_ca.3.gz","./usr/share/man/man3/umad_get_ca_namelist.3.gz","./usr/share/man/man3/umad_get_ca_portguids.3.gz","./usr/share/man/man3/umad_get_cas_names.3.gz","./usr/share/man/man3/umad_get_fd.3.gz","./usr/share/man/man3/umad_get_issm_path.3.gz","./usr/share/man/man3/umad_get_mad.3.gz","./usr/share/man/man3/umad_get_mad_addr.3.gz","./usr/share/man/man3/umad_get_pkey.3.gz","./usr/share/man/man3/umad_get_port.3.gz","./usr/share/man/man3/umad_init.3.gz","./usr/share/man/man3/umad_mad_status_str.3.gz","./usr/share/man/man3/umad_method_str.3.gz","./usr/share/man/man3/umad_open_port.3.gz","./usr/share/man/man3/umad_poll.3.gz","./usr/share/man/man3/umad_recv.3.gz","./usr/share/man/man3/umad_register.3.gz","./usr/share/man/man3/umad_register2.3.gz","./usr/share/man/man3/umad_register_oui.3.gz","./usr/share/man/man3/umad_release_ca.3.gz","./usr/share/man/man3/umad_release_port.3.gz","./usr/share/man/man3/umad_send.3.gz","./usr/share/man/man3/umad_set_addr.3.gz","./usr/share/man/man3/umad_set_addr_net.3.gz","./usr/share/man/man3/umad_set_grh.3.gz","./usr/share/man/man3/umad_set_grh_net.3.gz","./usr/share/man/man3/umad_set_pkey.3.gz","./usr/share/man/man3/umad_size.3.gz","./usr/share/man/man3/umad_status.3.gz","./usr/share/man/man3/umad_unregister.3.gz","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml","./usr/lib/python2.7/site-packages/dcbnetlink.pyc","./usr/lib/python2.7/site-packages/dcbnetlink.pyo","./usr/lib/python2.7/site-packages/genetlink.pyc","./usr/lib/python2.7/site-packages/genetlink.pyo","./usr/lib/python2.7/site-packages/netlink.pyc","./usr/lib/python2.7/site-packages/netlink.pyo"],"md5sum":"7b9b9865b5fdd9befe4303771ac77dae","name":"mlnx-ofa_kernel-4.9-OFED.4.9.3.1.6.1.rhel7u8.x86_64.rpm","release":"2021-05-17T17:34:05","revision":"0","sha1sum":"57bd4ea416be6ec748df3220fc64ee62b291859c","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"4.9"}],"id":{"product":"5ef718b94f9643ad8517d0050338c700","version":"54b86a13851e425c875ba06c33a95997"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)","OSVersion":{"name":"Linux","value":"6.9"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)","OSVersion":{"name":"Linux","value":"6.10"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)","OSVersion":{"name":"Linux","value":"7.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)","OSVersion":{"name":"Linux","value":"7.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-4.9&quot;&nbsp;RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.&nbsp;<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using kernel version 3.10.0-1127.el7.x86_64&nbsp;or any future errata:<br />\n<br />\n<strong># rpm -Uvh&nbsp;kmod-mlnx-ofa_kernel-4.9-OFED.4.9.3.1.6.1.rhel7u8.x86_64.rpm&nbsp;mlnx-ofa_kernel-4.9-OFED.4.9.3.1.6.1.rhel7u8.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for Red Hat Enterprise Linux 7 Update 8 (x86_64)"},{"lang":"ja","x_late":"HP Mellanox RoCE（RDMA over Converged Ethernet）ドライバーfor Red Hat Enterprise Linux 7 Update 8 (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-17T16:50:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>The following changes and new features are added in version 4.9:</strong></p>\n\n<ul>\n\t<li><strong>For ConnectX-5 Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Option to dump configuration space via the devlink tool in order to improve debug capabilities.</li>\n\t<li>The conventional TX descriptor (WQE or Work Queue Element) describes a single packet for transmission. Added driver support for the HW feature of multi-packet TX WQEs in XDP transmit flows. With this, the HW becomes capable of working with a new and improved WQE layout that describes several packets. In effect, this feature saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>GENEVE encapsulation/decapsulation rules offload.</li>\n\t<li>Driver support for the hardware feature of multi-packet Tx to work with a new and improved WQE layout that describes several packets instead of a single packet for XDP transmission flows. This saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>Updating CT (Connection Tracking) rules using the software steering mechanism.</li>\n\t<li>Updating remote mirroring rules using the software steering mechanism.<br />\n\t&nbsp;</li>\n\t<li><strong>For ConnectX-4&nbsp;Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Exposed rx_prio[p]_discards discard counters per priority that count the number of received packets dropped due to lack of buffers on the physical port.</li>\n\t<li>Reporting TSO and CSUM offload capabilities for MPLS tagged traffic and, allowed the kernel stack to use these offloads.</li>\n\t<li>mlx5e Max Combined Channels Increased the driver&rsquo;s maximal combined channels value from 64 to 128 (however, note that OOB value will not cross 64). 128 is the upper bound. Lower maximal value can be seen on the host, depending on the number of cores and MSIX&#39;s configured by the firmware.</li>\n\t<li>Added the following RoCE accelerator counters:\n\t<ul>\n\t\t<li>roce_adp_retrans - counts the number of adaptive retransmissions for RoCE traffic.</li>\n\t\t<li>roce_adp_retrans_to - counts the number of times RoCE traffic reached timeout due to adaptive retransmission.</li>\n\t\t<li>roce_slow_restart - counts the number of times RoCE slow restart was used.</li>\n\t\t<li>roce_slow_restart_cnps - counts the number of times RoCE slow restart generated CNP packets roce_slow_restart_trans - counts the number of times RoCE slow restart changed state to slow restart.</li>\n\t</ul>\n\t</li>\n\t<li>User to register memory regions with a relaxed ordering access flag through experimental verbs. This can enhance performance, depending on architecture and scenario.<br />\n\t&nbsp;</li>\n\t<li><strong>For&nbsp;All HCA&#39;s</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Output ibdev2netdev tool output was changed such that the bonding device now points at the bond instead of the slave interface.</li>\n\t<li>Monitoring and recovering from errors that occur on the RX queue, such as cookie errors and timeout.</li>\n\t<li>Improved GSO (Generic Segmentation Offload) workload performance by decreasing doorbells usage to the minimum required.</li>\n\t<li>TX CQE (Completion Queue Element) compression. Saves on outgoing PCIe bandwidth by compressing CQEs together. Disabled by default. Configurable via private flags of ethtool.</li>\n\t<li>Firmware Versions Query via Devlink :Added the option to query for running and stored firmware versions using the devlink tool.</li>\n\t<li>Firmware Flash Update via Devlink :Added the option to update the firmware image in the flash using the devlink tool. Usage: devlink dev flash file .mfa2 For further information on how to perform this update, see &quot;Updating Firmware Using ethtool/devlink and .mfa2 File&quot; section in MFT User Manual.</li>\n\t<li>WQE (Work Queue Element) dump, triggered by an error on Rx/Tx reporters. In addition, some dumps (not triggered by an error) can be retrieved by the user via devlink health reporters.</li>\n\t<li>GENEVE tunneled hardware offloads of TSO, CSUM and RSS.</li>\n\t<li>TCP segmentation and checksum offload support for MPLS-tagged traffic.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 4.9:</strong></p>\n\n<ul>\n\t<li>An issue where injecting EEH (Extended Error Handlng) may cause extra Kernel prints, such as: &ldquo;EEH: Might be infinite loop in mlx5_core driver&rdquo; was fixed.</li>\n\t<li>RPM-based OSs with non-default kernels, using repositories after re-creating the installer (using --add-kernel-support) were&nbsp;resulting&nbsp;in improper installation of the drivers.</li>\n\t<li>A typo in perftest package where help messages wrongly displayed the conversion result between Gb/s and MB/s (20^2 instead of 2^20).</li>\n\t<li>When one of the LAG slaves went down, LAG deactivation failed, ultimately causing bandwidth degradation.</li>\n\t<li>The mlx5 driver maintains a subdirectory for every open eth port in /sys/kernel/debug/. For the default network namespace, the sub-directory name is the name of the interface, like &quot;eth8&quot;. The new convention for the network interfaces moved to the non-default network namespaces is the interfaces name followed by &quot;@&quot; and the port&#39;s PCI ID. For example: &quot;eth8@0000:af:00.3&quot;.</li>\n\t<li>&quot;openibd&quot; script load used to fail when esp6_offload module did not load successfully.</li>\n\t<li>Added dependency of package mpi-selectors on perl-Getopt-Long system package. On minimal installs of RPM-based OSs, installing mpi-selectros will also install the required system package perl-Getopt-Long.</li>\n\t<li>During certain rare scenarios, due to Rx page not being replenished, the same page fragment mistakenly became assigned to two different Rx descriptors.</li>\n\t<li>Driver load issue existed with Errata-kernel on SLES15 SP1.</li>\n\t<li>An issue in the Hairpin feature which prevented adding hairpin flows using TC tool was fixed.</li>\n\t<li>WQ (Work Queue)&nbsp;queue flushing was not handled properly in the event of EEH.</li>\n\t<li>A rare kernel crash scenario when exiting an application that uses RMPP mads intensively.</li>\n\t<li>A possible kernel crash scenario when AER/slot reset in done in parallel to user space commands execution.</li>\n\t<li>Added missing ECN (Explicit Congestion Notification) configuration under sysfs for PFs in SwitchDev mode.</li>\n\t<li>When firmware response time to commands became very long, some commands failed upon timeout. The driver may have then triggered a timeout completion on the wrong entry, leading to a NULL pointer call trace.</li>\n\t<li>Added driver support for kernels with the old XDP_REDIRECT infrastructure that uses the following NetDev operations: .ndo_xdp_flush and .ndo_xdp_xmit.</li>\n\t<li>Usage of --excludedocs Open MPI RPM option resulted in the removal of non-documentation related files.</li>\n\t<li>Disabled automated loading of some modules through udev triggers to preserve the startup process of previous MLNX_OFED versions.</li>\n\t<li>Reference count (refcount) for RDMA connection ID (cm_id) was not incremented in rdma_resolve_addr() function, resulting in a cm_id use-after-free access. A fix was applied to increment the cm_id refcount</li>\n\t<li>A race condition which caused kernel panic when moving two ports to SwitchDev mode at the same time.</li>\n\t<li>Allowed accessing sysfs hardware counters in SwitchDev mode</li>\n\t<li>Function smp_processor_id() is called in the RX page recycle flow to determine the core to run on. This is intended to run in NAPI context. However, due to a bug in backporting, the RX page recycle was mistakenly called also in the RQ close flow when not needed.</li>\n\t<li>Port link state was automatically changed (without admin state involvement) to &quot;UP&quot; after reboot.</li>\n\t<li>ConnectX-3 adapter cards froze when running over SLES 11 OS.</li>\n\t<li>RDMA CM (Remote Direct Memory Access Communation Manager) connection failed when port space was small.</li>\n\t<li>Traffic mirroring with OVS (Open VSwitch)offload and non-offload over VxLAN interface is now supported. Note: For kernel 4.9, make sure to use a dedicated OVS version.</li>\n\t<li>When working with VF LAG while the bond device is in active-active mode, running fwreset would result in unequal traffic on both PFs, and PFs would not reach line rate.</li>\n\t<li>When bond was created over VF (Virtuaal Function)&nbsp;netdevices in SwitchDev mode, the VF netdevice would be treated as representor netdevice. This caused the mlx5_core driver to crash in case it received netdevice events related to bond device.</li>\n\t<li>An issue where following a bad affinity occurrence in VF LAG mode, traffic was sent after the port went up/down in the switch.</li>\n\t<li>Added support for VLAN (Virtual Local Area Network)&nbsp;header rewrite on CentOS 7.2 OS.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>The following changes and new features are added in version 4.9:</strong></p>\n\n<ul>\n\t<li><strong>For ConnectX-5 Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Option to dump configuration space via the devlink tool in order to improve debug capabilities.</li>\n\t<li>The conventional TX descriptor (WQE or Work Queue Element) describes a single packet for transmission. Added driver support for the HW feature of multi-packet TX WQEs in XDP transmit flows. With this, the HW becomes capable of working with a new and improved WQE layout that describes several packets. In effect, this feature saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>GENEVE encapsulation/decapsulation rules offload.</li>\n\t<li>Driver support for the hardware feature of multi-packet Tx to work with a new and improved WQE layout that describes several packets instead of a single packet for XDP transmission flows. This saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>Updating CT (Connection Tracking) rules using the software steering mechanism.</li>\n\t<li>Updating remote mirroring rules using the software steering mechanism.<br />\n\t&nbsp;</li>\n\t<li><strong>For ConnectX-4&nbsp;Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Exposed rx_prio[p]_discards discard counters per priority that count the number of received packets dropped due to lack of buffers on the physical port.</li>\n\t<li>Reporting TSO and CSUM offload capabilities for MPLS tagged traffic and, allowed the kernel stack to use these offloads.</li>\n\t<li>mlx5e Max Combined Channels Increased the driver&rsquo;s maximal combined channels value from 64 to 128 (however, note that OOB value will not cross 64). 128 is the upper bound. Lower maximal value can be seen on the host, depending on the number of cores and MSIX&#39;s configured by the firmware.</li>\n\t<li>Added the following RoCE accelerator counters:\n\t<ul>\n\t\t<li>roce_adp_retrans - counts the number of adaptive retransmissions for RoCE traffic.</li>\n\t\t<li>roce_adp_retrans_to - counts the number of times RoCE traffic reached timeout due to adaptive retransmission.</li>\n\t\t<li>roce_slow_restart - counts the number of times RoCE slow restart was used.</li>\n\t\t<li>roce_slow_restart_cnps - counts the number of times RoCE slow restart generated CNP packets roce_slow_restart_trans - counts the number of times RoCE slow restart changed state to slow restart.</li>\n\t</ul>\n\t</li>\n\t<li>User to register memory regions with a relaxed ordering access flag through experimental verbs. This can enhance performance, depending on architecture and scenario.<br />\n\t&nbsp;</li>\n\t<li><strong>For&nbsp;All HCA&#39;s</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Output ibdev2netdev tool output was changed such that the bonding device now points at the bond instead of the slave interface.</li>\n\t<li>Monitoring and recovering from errors that occur on the RX queue, such as cookie errors and timeout.</li>\n\t<li>Improved GSO (Generic Segmentation Offload) workload performance by decreasing doorbells usage to the minimum required.</li>\n\t<li>TX CQE (Completion Queue Element) compression. Saves on outgoing PCIe bandwidth by compressing CQEs together. Disabled by default. Configurable via private flags of ethtool.</li>\n\t<li>Firmware Versions Query via Devlink :Added the option to query for running and stored firmware versions using the devlink tool.</li>\n\t<li>Firmware Flash Update via Devlink :Added the option to update the firmware image in the flash using the devlink tool. Usage: devlink dev flash file .mfa2 For further information on how to perform this update, see &quot;Updating Firmware Using ethtool/devlink and .mfa2 File&quot; section in MFT User Manual.</li>\n\t<li>WQE (Work Queue Element) dump, triggered by an error on Rx/Tx reporters. In addition, some dumps (not triggered by an error) can be retrieved by the user via devlink health reporters.</li>\n\t<li>GENEVE tunneled hardware offloads of TSO, CSUM and RSS.</li>\n\t<li>TCP segmentation and checksum offload support for MPLS-tagged traffic.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 4.9:</strong></p>\n\n<ul>\n\t<li>An issue where injecting EEH (Extended Error Handlng) may cause extra Kernel prints, such as: &ldquo;EEH: Might be infinite loop in mlx5_core driver&rdquo; was fixed.</li>\n\t<li>RPM-based OSs with non-default kernels, using repositories after re-creating the installer (using --add-kernel-support) were&nbsp;resulting&nbsp;in improper installation of the drivers.</li>\n\t<li>A typo in perftest package where help messages wrongly displayed the conversion result between Gb/s and MB/s (20^2 instead of 2^20).</li>\n\t<li>When one of the LAG slaves went down, LAG deactivation failed, ultimately causing bandwidth degradation.</li>\n\t<li>The mlx5 driver maintains a subdirectory for every open eth port in /sys/kernel/debug/. For the default network namespace, the sub-directory name is the name of the interface, like &quot;eth8&quot;. The new convention for the network interfaces moved to the non-default network namespaces is the interfaces name followed by &quot;@&quot; and the port&#39;s PCI ID. For example: &quot;eth8@0000:af:00.3&quot;.</li>\n\t<li>&quot;openibd&quot; script load used to fail when esp6_offload module did not load successfully.</li>\n\t<li>Added dependency of package mpi-selectors on perl-Getopt-Long system package. On minimal installs of RPM-based OSs, installing mpi-selectros will also install the required system package perl-Getopt-Long.</li>\n\t<li>During certain rare scenarios, due to Rx page not being replenished, the same page fragment mistakenly became assigned to two different Rx descriptors.</li>\n\t<li>Driver load issue existed with Errata-kernel on SLES15 SP1.</li>\n\t<li>An issue in the Hairpin feature which prevented adding hairpin flows using TC tool was fixed.</li>\n\t<li>WQ (Work Queue)&nbsp;queue flushing was not handled properly in the event of EEH.</li>\n\t<li>A rare kernel crash scenario when exiting an application that uses RMPP mads intensively.</li>\n\t<li>A possible kernel crash scenario when AER/slot reset in done in parallel to user space commands execution.</li>\n\t<li>Added missing ECN (Explicit Congestion Notification) configuration under sysfs for PFs in SwitchDev mode.</li>\n\t<li>When firmware response time to commands became very long, some commands failed upon timeout. The driver may have then triggered a timeout completion on the wrong entry, leading to a NULL pointer call trace.</li>\n\t<li>Added driver support for kernels with the old XDP_REDIRECT infrastructure that uses the following NetDev operations: .ndo_xdp_flush and .ndo_xdp_xmit.</li>\n\t<li>Usage of --excludedocs Open MPI RPM option resulted in the removal of non-documentation related files.</li>\n\t<li>Disabled automated loading of some modules through udev triggers to preserve the startup process of previous MLNX_OFED versions.</li>\n\t<li>Reference count (refcount) for RDMA connection ID (cm_id) was not incremented in rdma_resolve_addr() function, resulting in a cm_id use-after-free access. A fix was applied to increment the cm_id refcount</li>\n\t<li>A race condition which caused kernel panic when moving two ports to SwitchDev mode at the same time.</li>\n\t<li>Allowed accessing sysfs hardware counters in SwitchDev mode</li>\n\t<li>Function smp_processor_id() is called in the RX page recycle flow to determine the core to run on. This is intended to run in NAPI context. However, due to a bug in backporting, the RX page recycle was mistakenly called also in the RQ close flow when not needed.</li>\n\t<li>Port link state was automatically changed (without admin state involvement) to &quot;UP&quot; after reboot.</li>\n\t<li>ConnectX-3 adapter cards froze when running over SLES 11 OS.</li>\n\t<li>RDMA CM (Remote Direct Memory Access Communation Manager) connection failed when port space was small.</li>\n\t<li>Traffic mirroring with OVS (Open VSwitch)offload and non-offload over VxLAN interface is now supported. Note: For kernel 4.9, make sure to use a dedicated OVS version.</li>\n\t<li>When working with VF LAG while the bond device is in active-active mode, running fwreset would result in unequal traffic on both PFs, and PFs would not reach line rate.</li>\n\t<li>When bond was created over VF (Virtuaal Function)&nbsp;netdevices in SwitchDev mode, the VF netdevice would be treated as representor netdevice. This caused the mlx5_core driver to crash in case it received netdevice events related to bond device.</li>\n\t<li>An issue where following a bad affinity occurrence in VF LAG mode, traffic was sent after the port went up/down in the switch.</li>\n\t<li>Added support for VLAN (Virtual Local Area Network)&nbsp;header rewrite on CentOS 7.2 OS.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"kmod-mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000GFEMH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNFG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304746454d48","Version":"HPG6"},{"DeviceName":"MB4000GFEMK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNFG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304746454d4b","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB2000GFEMH and MB4000GFEMK"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB2000GFEMHおよびMB4000GFEMK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB2000GFEMH and MB4000GFEMK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.&nbsp; This issue was found during supplier ongoing reliability testing.</p>\n\t</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5550738","datemodified":"2021-07-23T06:14:36","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-70e3962f98-HPG6-9.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-70e3962f98-HPG6-9.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-70e3962f98-HPG6-9.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-70e3962f98-HPG6-9.1/CP048149.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-70e3962f98-HPG6-9.1/HAKPNFG6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-70e3962f98-HPG6-9.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-70e3962f98-HPG6-9.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-70e3962f98-HPG6-9.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-70e3962f98-HPG6-9.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048149.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048149.scexe"],"md5sum":"fbf17f8ee78bf0b29b6746f488623cb1","name":"firmware-hdd-70e3962f98-HPG6-9.1.x86_64.rpm","release":"2021-07-23T06:02:08","revision":"0","sha1sum":"7960b01f46abab8269f3760cc117c96df1561940","size":"5MB","target_guids":["002340a5-4d00-3242-3030-304746454d48","002340a5-4d00-3442-3030-304746454d4b"],"type_of_change":"2","version":"HPG6"}],"id":{"product":"1195ecfa03744617a13d6f9abdc72e2b","version":"65118f0cbb71454f9b48bf4991440400"},"installation":{"command":"CP040331.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB2000GFEMH and MB4000GFEMK Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB2000GFEMHおよびMB4000GFEMKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB2000GFEMH","target_guid":"002340a5-4d00-3242-3030-304746454d48","type":"sata"},{"id":"MB4000GFEMK","target_guid":"002340a5-4d00-3442-3030-304746454d4b","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-26T18:49:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was found during supplier ongoing reliability testing.</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was found during supplier ongoing reliability testing.</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000GFEMK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB2000GFEMH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Broadcom NetXtreme-E NICs running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 8で動作するHPE Broadcom NetXtreme-E NIC用のドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"332663","datemodified":"2021-01-14T07:59:42","file_list":["./etc/depmod.d/bnxt_en.conf","./etc/depmod.d/bnxt_re.conf","./lib/modules/4.18.0-193.el8.x86_64","./lib/modules/4.18.0-193.el8.x86_64/extra","./lib/modules/4.18.0-193.el8.x86_64/extra/bnxt_en","./lib/modules/4.18.0-193.el8.x86_64/extra/bnxt_en/bnxt_en.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/bnxt_en/drivers","./lib/modules/4.18.0-193.el8.x86_64/extra/bnxt_en/drivers/infiniband","./lib/modules/4.18.0-193.el8.x86_64/extra/bnxt_en/drivers/infiniband/hw","./lib/modules/4.18.0-193.el8.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re","./lib/modules/4.18.0-193.el8.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/lib/.build-id","./usr/lib/.build-id/57","./usr/lib/.build-id/57/f604ce6ba689784fd16c28956d99419bbca20d","./usr/lib/.build-id/f8","./usr/lib/.build-id/f8/3e8c1d1aab8e96a48688e3bb3ec6ec6e5b3769","./usr/share/smartupdate/kmod-bnxt_en/component.xml"],"md5sum":"d282c5d26409b0130dbe7aa194b56859","name":"kmod-bnxt_en-1.10.2-218.0.67.0.rhel8u2.x86_64.rpm","release":"2021-01-14T07:45:04","revision":"0","sha1sum":"ebc7e3ce47119cb2d3498e006f593b4cc34e30df","size":"324KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af"],"type_of_change":"0","version":"1.10.2-218.0.67.0"},{"bytes":"332571","datemodified":"2021-01-14T07:56:41","file_list":["./etc/depmod.d/bnxt_en.conf","./etc/depmod.d/bnxt_re.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/bnxt_en","./lib/modules/4.18.0-240.el8.x86_64/extra/bnxt_en/bnxt_en.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/bnxt_en/drivers","./lib/modules/4.18.0-240.el8.x86_64/extra/bnxt_en/drivers/infiniband","./lib/modules/4.18.0-240.el8.x86_64/extra/bnxt_en/drivers/infiniband/hw","./lib/modules/4.18.0-240.el8.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re","./lib/modules/4.18.0-240.el8.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/lib/.build-id","./usr/lib/.build-id/85","./usr/lib/.build-id/85/e71560552c72a92a8b798570ff996d89e31f7b","./usr/lib/.build-id/d2","./usr/lib/.build-id/d2/423e5bc79db491636e0b46f6d0095f0c0a1bb6","./usr/share/smartupdate/kmod-bnxt_en/component.xml"],"md5sum":"918ab36dba5801be59b738d85f15ed59","name":"kmod-bnxt_en-1.10.2-218.0.67.0.rhel8u3.x86_64.rpm","release":"2021-01-14T07:45:04","revision":"0","sha1sum":"f21c6db8df7eb16a99121a034e433b0699f8a03b","size":"324KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af"],"type_of_change":"0","version":"1.10.2-218.0.67.0"}],"id":{"product":"12bc299e14c0483f95f66950ee1bea77","version":"e3a4f5c54acb4a5dac4f8ca4f09a183b"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>Download README for any additional installation instructions.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE Broadcom NetXtreme-Eドライバーfor Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>This product now supports Red Hat Enterprise Linux 8 Update 1</li>\n\t<li>This product now sets Maximum Transmission Unit(MTU) default value from firmware returned value</li>\n\t<li>This product now not support user establishing connections using RDMA communication manager(CM) when Priority-based Flow Control (PFC) configured VLAN ID is 0</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>This product corrects an issue which offload is not happening on bond(vf and virtio) interface after the fail over with VF as the active slave</li>\n\t<li>This product corrects an issue which driver loading failed on kdump kernel.</li>\n\t<li>This product corrects an issue which RoCE driver causes input&ndash;output memory management unit(IOMMU) warnings</li>\n\t<li>This product corrects an issue which RoCE Link Aggregation (RoCE LAG) when Maximum Transmission Unit(MTU) was changed.</li>\n\t<li>This product corrects an issue which Link up failed after resuming from hibernation</li>\n\t<li>This product corrects an issue which Virtual Function RoCE driver causes Virtual Machine to be rebooted</li>\n\t<li>This product corrects an issue which errata kernel loads inbox driver instead of this component after booting into OS</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>This product now supports Red Hat Enterprise Linux 8 update 2 and Red Hat Enterprise Linux 8 update 3</li>\n\t<li>This product now supports PAM4 speeds information in&nbsp;ethtool tools&nbsp;</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where system crashed on doing driver unload load in loop when running broadcast traffic</li>\n\t<li>This product addresses an issue where bnxt_en module crashes with NULL pointer deference before ifup(bring up network interface)</li>\n\t<li>This product addresses an issue where kernel panic after PCIe AER(Advanced Error Reporting) device recovery successful</li>\n\t<li>This product addresses an issue where bnxt_en crashes with NULL pointer dereference when enabling SRIOV</li>\n\t<li>This product correct an error where ethtool -S tx_bytes and rx_bytes counter values far exceed actual values</li>\n\t<li>This product correct an error message when querying hwmon temperature on VF via sysfs</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-bnxt_en","sw_key_expectedpath":"software:rpm"},{"name":"kmod-bnxt_en","sw_key_expectedpath":"software:rpm"},{"name":"kmod-bnxt_en","sw_key_expectedpath":"software:rpm"},{"name":"kmod-bnxt_en","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO001600KWZQP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173500HPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b575a5150","Version":"HPK5"},{"DeviceName":"MO003200KWZQQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173500HPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b575a5151","Version":"HPK5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MO001600KWZQP and MO003200KWZQQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online NVMe SSD Flash Component for Windows (x64) - MO001600KWZQP and MO003200KWZQQ Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"7555776","datemodified":"2021-07-24T10:35:50","file_list":["cp048685.xml","cpqsetup.exe","GP173500HPK5.rel","payload.json","setup.dll"],"md5sum":"1df1a04aac60ed58a810c16ff285d4e1","name":"cp048685.exe","release":"2021-07-24T10:28:11","revision":"0","sha1sum":"99668f3a204e4064f95692462df92b3f625eb6a5","size":"7MB","target_guids":["4d2340a5-304f-3130-3630-304b575a5150","4d2340a5-304f-3330-3230-304b575a5151"],"type_of_change":"2","version":"HPK5"}],"id":{"product":"7f41af98f1f247caa57376b98f09238f","version":"3b04b64a05324f309e69ac9506292745"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) - MO001600KWZQP and MO003200KWZQQ Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - MO001600KWZQPおよびMO003200KWZQQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MO003200KWZQQ","target_guid":"4d2340a5-304f-3330-3230-304b575a5151","type":"nvme"},{"id":"MO001600KWZQP","target_guid":"4d2340a5-304f-3130-3630-304b575a5150","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-17T09:33:58","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MO003200KWZQQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO001600KWZQP","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK0960GECQK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSV843G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304b-3936-30474543514b","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MK0960GECQK"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MK0960GECQK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MK0960GECQK Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:<br />\n&nbsp; &nbsp; &nbsp;</strong>None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Firmware fixes intermittent data corruption issue associated with unaligned sequential write operations.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"15633440","datemodified":"2021-08-27T05:58:28","file_list":["/CP048387_BUILD_2.data","/CP048387.vmexe","/CP048387.vmexe64","/CP048387.vmfile","/CP048387_VMw.zip","/CP048387.xml","/payload.json","/CP048387_VMw.zip/index.xml","/CP048387_VMw.zip/vendor-index.xml","/CP048387_VMw.zip/metadata.zip","/CP048387_VMw.zip/vib20/CP048387/HPE_bootbank_CP048387_HPG3.2-7.0.0.15843807.vib","/CP048387_VMw.zip/metadata.zip/vendor-index.xml","/CP048387_VMw.zip/metadata.zip/vmware.xml","/CP048387_VMw.zip/metadata.zip/vibs/CP048387-7221830640815724014.xml","/CP048387_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048387_HPG3.2-7.0.0.15843807.xml"],"md5sum":"4ebc221f0691ab8a84391eaf02ccb84d","name":"CP048387.zip","release":"2021-08-27T05:52:45","revision":"0","sha1sum":"3977c595c5af8af4659be7cc37f5a2a7723e0c4f","size":"14MB","target_guids":["002340a5-4d00-304b-3936-30474543514b"],"type_of_change":"2","version":"HPG3","vib_list":[{"name":"CP048387","version":"HPG3.2-7.0.0.15843807"}]}],"id":{"product":"fbb06cc4248449e08cfdf0ed7c07c5e1","version":"9e59777e9fa4416babfe866bc3c92b97"},"installation":{"command":"CP042541.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MK0960GECQK Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - MK0960GECQKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"MK0960GECQK","target_guid":"002340a5-4d00-304b-3936-30474543514b","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T10:03:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Firmware fixes intermittent data corruption issue associated with unaligned sequential write operations.</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Firmware fixes intermittent data corruption issue associated with unaligned sequential write operations.</li>\n</ul>","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK0960GECQK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the NIC and RoCE drivers for HPE Broadcom NetXtreme-E devices running under VMware vSphere 7.0."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains NIC driver version&nbsp;218.0.38.0 and RoCE driver version&nbsp;218.0.16.0.</p>\n"}],"files":[{"bytes":"389232","datemodified":"2021-01-14T06:18:18","file_list":["/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.700.1.0.15843807_17359297.zip","/cp045075.xml","/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.700.1.0.15843807_17359297.zip/index.xml","/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.700.1.0.15843807_17359297.zip/vendor-index.xml","/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.700.1.0.15843807_17359297.zip/metadata.zip","/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.700.1.0.15843807_17359297.zip/vib20/bnxtnet/BCM_bootbank_bnxtnet_218.0.38.0-1OEM.700.1.0.15843807.vib","/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.700.1.0.15843807_17359297.zip/vib20/bnxtroce/BCM_bootbank_bnxtroce_218.0.16.0-1OEM.700.1.0.15843807.vib","/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.700.1.0.15843807_17359297.zip/metadata.zip/vendor-index.xml","/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.700.1.0.15843807_17359297.zip/metadata.zip/vmware.xml","/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.700.1.0.15843807_17359297.zip/metadata.zip/vibs/bnxtnet-2270757399935237568.xml","/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.700.1.0.15843807_17359297.zip/metadata.zip/vibs/bnxtroce--4512647262758159893.xml","/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.700.1.0.15843807_17359297.zip/metadata.zip/bulletins/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.700.1.0.15843807.xml"],"md5sum":"0c3fbf91869dc97b4f525ef2be2e19bd","name":"cp045075.zip","release":"2021-01-14T06:17:05","revision":"0","sha1sum":"db314b401812e94ac0ad236d32212247e3ccd4e8","size":"380KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec158e843a","20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476","20a6e8e4-bf33-4c71-a6bf-d9ecc7b58dd7"],"type_of_change":"0","version":"2021.04.05","vib_list":[{"name":"bnxtnet","version":"218.0.38.0-1OEM.700.1.0.15843807"},{"name":"bnxtroce","version":"218.0.16.0-1OEM.700.1.0.15843807"}]}],"id":{"product":"11a6992c4ec7430e9b4f2b44f5d06fe1","version":"9fd6d7637c6d4917a99111f0453038b8"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product corrects an issue which Purple Screen Of Death (PSOD) while running &nbsp;Virtual SAN (vSAN) over &nbsp;Remote Direct Memory Access (RDMA) traffic due to invalid Completion Queue Element (CQEs)</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"bnxtnet:218.0.38.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"bnxtroce:218.0.16.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"Broadcom-bnxt-Net-RoCE:218.0.243.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver.component:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]},{"key":"7800374","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"en","x_late":"Provides miscellaneous utilities in support of the HPE supported Fibre Channel host bus adapter drivers."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"27811","datemodified":"2021-08-26T07:48:37","file_list":["./etc/.hp_fibreutils","./opt/hp/hp_fibreutils/adapter_info","./opt/hp/hp_fibreutils/adapter_info_nx","./opt/hp/hp_fibreutils/hp_rescan","./opt/hp/hp_fibreutils/lssd","./opt/hp/hp_fibreutils/lssg","./opt/hp/hp_fibreutils/scsi_info","./usr/bin/adapter_info","./usr/bin/adapter_info_nx","./usr/bin/hp_rescan","./usr/bin/lssd","./usr/bin/lssg","./usr/bin/scsi_info","./usr/share/smartupdate/fibreutils/component.xml"],"md5sum":"4561678c9a508160525418c3410563ee","name":"fibreutils-4.1-1_sles.x86_64.rpm","release":"2021-08-26T07:43:24","revision":"0","sha1sum":"c90fcbc83348e9126da691a370926d2823937416","size":"27KB","target_guids":[],"type_of_change":"0","version":"4.1-1"}],"id":{"product":"51e7bcbb81894e3682b10bb6544e4db6","version":"8a33570026d748539e82ec906d127faa"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download fibreutils RPM. <BR>Use rpm -Uvh command to install/upgrade RPM."}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Fibreutils for HPE Storage Fibre Channel Host Bus Adapters for Linux -SuSE Linux Enterprise Server(SLES)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T09:15:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This package supports only SuSE Linux Enterprise Server(SLES) Distros</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"fibreutils","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"8682361","datemodified":"2021-05-17T21:40:47","file_list":["/CP047850.vmexe","/CP047850.vmexe64","/CP047850.vmfile","/CP047850.xml","/README.txt"],"md5sum":"76a634f48570776913554db8860f6bf1","name":"CP047850.zip","release":"2021-05-18T02:37:22","revision":"0","sha1sum":"5224e47fa997b77884447925c79aaae5a29a60b0","size":"8MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021","vib_list":[]}],"id":{"product":"c9be2188c9e74afcbe220603b395a9de","version":"ae09e5af86de43418ad5529e3e477f21"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component requires that the CRU driver be loaded before the component can run.<br />\nThe minimum CRU version for 5.1 is 5.0.3.9.<br />\nThe minimum CRU version for 5.5 is 5.5.4.1.<br />\nThe minimum CRU version for 6.0 is 6.0.8.<br />\nThe minimum CRU version for 6.5 is 6.5.8.<br />\nThe minimum CRU version for 6.7 is 6.7.10.<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>SPP Offline mode boots a special Linux OS environment, thus the Linux Components are used, not the VMware Components</li>\n</ul>\n\n<p><br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Download the appropriate SPP</li>\n\t<li>Add the component to the SPP</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run SUM</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps to complete the firmware update</li>\n\t<li>Refer to the SPP documentation for detailed instructions at:&nbsp; <a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Component ( CPxxxxxx.zip) in a temporary directory</li>\n\t<li>From the same directory, unzip the Component:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>To perform the standalone installation, execute the command:<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>Follow the directions given by the Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system for the firmware update to take effect</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、実行する前にCRUドライバーがロードされている必要があります。<br />\n5.1の最小CRUバージョンは5.0.3.9です。<br />\n5.5の最小CRUバージョンは5.5.4.1です。<br />\n6.0の最小CRUバージョンは6.0.8です。<br />\n6.5の最小CRUバージョンは6.5.8です。<br />\n6.7の最小CRUバージョンは6.7.10です。<br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMwareコンポーネントではなく、Linuxコンポーネントが用いられます</li>\n</ul>\n\n<p><br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします</li>\n\t<li>SPPにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします</li>\n\t<li>SUMを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います</li>\n\t<li>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>コンポーネント (CPxxxxxx.zip)を一時ディレクトリに置きます</li>\n\t<li>同じディレクトリからコンポーネントをunzipします:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>スタンドアロンのインストールを行うために、次のコマンドを実行します：<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>コンポーネントの指示に従います</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n\t<li>システムを再起動し、ファームウェアのアップデートを有効にします</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware - HPE ProLiant DL560 Gen9 (P85) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for VMware - HPE ProLiant DL560 Gen9（P85）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"5","minor":"1","name":"VMware vSphere 5.1","platform":"vmware_esx_server","sr":"OEM"},{"major":"5","minor":"5","name":"VMware vSphere 5.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-05T03:51:27","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>Ver. 2.80_10-16-2020(B) contains updates to the component packaging and is functionally equivalent to ver. 2.80_10-16-2020. It is not necessary to upgrade with Revision (B) if a previous component revision was used to upgrade the firmware to 2.80_10-16-2020.</p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"}],"sw_keys":[{"name":"P85","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"HPE Dynamic Smart Array controller driver component(hpdsa) for VMware vSphere 6.7, for use with Smart Update Manager."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"993285","datemodified":"2021-07-14T17:35:50","file_list":["/cp048935.xml","/hpdsa-6.0.0.76-1-offline_bundle-18283990.zip","/hpdsa-6.0.0.76-1-offline_bundle-18283990.zip/index.xml","/hpdsa-6.0.0.76-1-offline_bundle-18283990.zip/vendor-index.xml","/hpdsa-6.0.0.76-1-offline_bundle-18283990.zip/metadata.zip","/hpdsa-6.0.0.76-1-offline_bundle-18283990.zip/vib20/scsi-hpdsa/HPE_bootbank_scsi-hpdsa_6.0.0.76-1OEM.600.0.0.2494585.vib","/hpdsa-6.0.0.76-1-offline_bundle-18283990.zip/metadata.zip/vendor-index.xml","/hpdsa-6.0.0.76-1-offline_bundle-18283990.zip/metadata.zip/vmware.xml","/hpdsa-6.0.0.76-1-offline_bundle-18283990.zip/metadata.zip/bulletins/hpdsa-6.0.0.76-1.xml","/hpdsa-6.0.0.76-1-offline_bundle-18283990.zip/metadata.zip/vibs/scsi-hpdsa--4653470427967347113.xml"],"md5sum":"9354548c803745df51c445cfefcf6447","name":"cp048935.zip","release":"2021-07-14T17:35:05","revision":"0","sha1sum":"48d3dcb5efc666371be71ab6a021a7c6b720eddc","size":"970KB","target_guids":[],"type_of_change":"1","version":"2021.09.01","vib_list":[{"name":"scsi-hpdsa","version":"6.0.0.76-1OEM.600.0.0.2494585"}]}],"id":{"product":"a52a8072bd114cfd99c6c7548b2a473e","version":"eb9b3a4ddece4cf0b698e9c22d72e9e4"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant</strong></p>\n\n<p><strong>Remote Online:</strong></p>\n\n<ul>\n\t<li>Place the SPP on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\"><u>HPE USB Key Creator Utility</u></a>.</li>\n\t<li>Place the desired driver to be updated in the directory, /SPP20xxxxx/hp/swpackages on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux</li>\n\t<li>CD /hp/swpackages and ./hpsum</li>\n\t<li>Select the next button</li>\n\t<li>Click Add Single Target</li>\n\t<li>Type the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>Follow Smart Update Manager Steps and complete the update.</li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware VUM or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands.</li>\n</ul>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、HPE Service Pack for ProLiantから以下の手順に従ってください</strong></p>\n\n<p><strong>リモートオンライン:</strong></p>\n\n<ul>\n\t<li><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\"><u>HPE USB Key Creator Utility</u></a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの/SPP20xxxxx/hp/swpackagesディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。</li>\n\t<li>CD /hp/swpackagesおよび./hpsum</li>\n\t<li>次へボタンを選択します。</li>\n\t<li>シングルターゲットの追加をクリックします。</li>\n\t<li>更新されるESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ul>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ul>\n\t<li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li>\n\t<li>オフラインバンドルをインストールするために、VMware VUMまたはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ul>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Dynamic Smart Array B140i Controller Driver for VMware vSphere 6.7 (Driver Component)."}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"8D06","subdev":"009C","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"8D66","subdev":"009D","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"A106","subdev":"00C0","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"A107","subdev":"00C0","subven":"1590","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-14T17:19:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Fixes an issue where the driver will not upgrade due to the AHCI driver taking priority.</p>\n\n<p>&nbsp;</p>\n\n<p>This issue is only encounter when upgrading to version 2018.09.31 (5.5.0.66-1). All other versions are not affected.</p>\n"},{"curr_enhancements_x_late":"<p>.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"}],"sw_keys":[{"name":"scsi-hpdsa:6.0.0.76-1OEM.550.0.0.1331820","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000GCWLT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HMKPB6G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304743574c54","Version":"HPG4"},{"DeviceName":"MB3000GCWLU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HMKPB6G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304743574c55","Version":"HPG4"},{"DeviceName":"MB4000GCWLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HMKPB6G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304743574c56","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB2000GCWLT, MB3000GCWLU and MB4000GCWLV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MB2000GCWLT, MB3000GCWLU&nbsp;and MB4000GCWLV Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3328032","datemodified":"2021-07-25T13:10:13","file_list":["cp048574.xml","cpqsetup.exe","HMKPB6G4.rel","payload.json","setup.dll"],"md5sum":"5157c82ceaa3ff681b23b83b07862bae","name":"cp048574.exe","release":"2021-07-25T13:02:04","revision":"0","sha1sum":"f300693b3aa8c95d42c287da230911a2fdb16a9e","size":"3MB","target_guids":["002340a5-4d00-3242-3030-304743574c54","002340a5-4d00-3342-3030-304743574c55","002340a5-4d00-3442-3030-304743574c56"],"type_of_change":"1","version":"HPG4"}],"id":{"product":"451308857c63431786ef6960ba605a64","version":"e154e90d0509411c8f488523ed20281a"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB2000GCWLT, MB3000GCWLU and MB4000GCWLV Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB2000GCWLT、MB3000GCWLU、およびMB4000GCWLVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"MB2000GCWLT","target_guid":"002340a5-4d00-3242-3030-304743574c54","type":"sata"},{"id":"MB3000GCWLU","target_guid":"002340a5-4d00-3342-3030-304743574c55","type":"sata"},{"id":"MB4000GCWLV","target_guid":"002340a5-4d00-3442-3030-304743574c56","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T09:09:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000GCWLV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB2000GCWLT","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB3000GCWLU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000JEFNC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRASD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a45464e43","Version":"HPD9"},{"DeviceName":"MB6000JEFND","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRASD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a45464e44","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB4000JEFNC and MB6000JEFND"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MB4000JEFNCおよびMB6000JEFND"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB4000JEFNC and MB6000JEFND Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"17495665","datemodified":"2021-08-26T19:56:59","file_list":["/CP048367_BUILD_3.data","/CP048367.vmexe","/CP048367.vmexe64","/CP048367.vmfile","/CP048367_VMw.zip","/CP048367.xml","/payload.json","/CP048367_VMw.zip/index.xml","/CP048367_VMw.zip/vendor-index.xml","/CP048367_VMw.zip/metadata.zip","/CP048367_VMw.zip/vib20/CP048367/HPE_bootbank_CP048367_HPD9.3-7.0.0.15843807.vib","/CP048367_VMw.zip/metadata.zip/vendor-index.xml","/CP048367_VMw.zip/metadata.zip/vmware.xml","/CP048367_VMw.zip/metadata.zip/vibs/CP048367-1879748335820545526.xml","/CP048367_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048367_HPD9.3-7.0.0.15843807.xml"],"md5sum":"660c8fff3c1eeda5f15f0d88452eab77","name":"CP048367.zip","release":"2021-08-26T19:51:41","revision":"0","sha1sum":"0df1d4f085449637de1f3870d03864912245e5ae","size":"16MB","target_guids":["002340a5-4d00-3442-3030-304a45464e43","002340a5-4d00-3642-3030-304a45464e44"],"type_of_change":"1","version":"HPD9","vib_list":[{"name":"CP048367","version":"HPD9.3-7.0.0.15843807"}]}],"id":{"product":"334426b326da4b9caa59be228e5282e3","version":"da2acbbd90834d94b0ee81f3b4935a81"},"installation":{"command":"CP039427.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB4000JEFNC and MB6000JEFND Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - MB4000JEFNCおよびMB6000JEFNDドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB4000JEFNC","target_guid":"002340a5-4d00-3442-3030-304a45464e43","type":"sas"},{"id":"MB6000JEFND","target_guid":"002340a5-4d00-3642-3030-304a45464e44","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-07T19:20:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JEFNC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB6000JEFND","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG0600JEMCV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3630-304a454d4356","Version":"HPD6"},{"DeviceName":"EG1200JEMDA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3230-304a454d4441","Version":"HPD6"},{"DeviceName":"EG0300JFCKA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3330-304a46434b41","Version":"HPD6"},{"DeviceName":"EG0900JFCKB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3930-304a46434b42","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG0300JFCKA, EG0600JEMCV, EG0900JFCKB and EG1200JEMDA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - EG0300JFCKA, EG0600JEMCV, EG0900JFCKB&nbsp;and EG1200JEMDA Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp; </strong>None</p>\n"}],"files":[{"bytes":"3658200","datemodified":"2021-07-24T06:47:25","file_list":["cp048483.xml","cpqsetup.exe","payload.json","setup.dll","STHBTND6.rel"],"md5sum":"dded403e19e35908a7823652d1cd5f7b","name":"cp048483.exe","release":"2021-07-24T06:40:05","revision":"0","sha1sum":"3a5ac6c08a15661e776d6288f1450f09edd9c6f6","size":"3MB","target_guids":["002340a5-4500-3047-3630-304a454d4356","002340a5-4500-3147-3230-304a454d4441","002340a5-4500-3047-3330-304a46434b41","002340a5-4500-3047-3930-304a46434b42"],"type_of_change":"1","version":"HPD6"}],"id":{"product":"935cb1f792604e6aaead9dbf6e50463c","version":"e7d22503884c4dfa920c6700e634ca14"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG0300JFCKA, EG0600JEMCV, EG0900JFCKB and EG1200JEMDA Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EG0300JFCKA、EG0600JEMCV、EG0900JFCKB、およびEG1200JEMDAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG1200JEMDA","target_guid":"002340a5-4500-3147-3230-304a454d4441","type":"sas"},{"id":"EG0300JFCKA","target_guid":"002340a5-4500-3047-3330-304a46434b41","type":"sas"},{"id":"EG0600JEMCV","target_guid":"002340a5-4500-3047-3630-304a454d4356","type":"sas"},{"id":"EG0900JFCKB","target_guid":"002340a5-4500-3047-3930-304a46434b42","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-14T06:06:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG1200JEMDA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0600JEMCV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0900JFCKB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0300JFCKA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the iSCSI driver for the HPE Blade Emulex 10/20GbE Server Adapters running under VMware vSphere 6.7."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;12.0.1188.0.</p>\n"}],"files":[{"bytes":"3564592","datemodified":"2019-10-24T14:37:29","file_list":["/cp039935.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/elxiscsi-12.0.1188.0-1OEM.670.0.0.8169922.x86_64.vib","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/ELX-ESX-libelxima-8169922.so-12.0.1188.0.vib","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/doc/README.txt","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/doc/release_note_elxiscsi_12.0.1188.0-1OEM.670.0.0.8169922.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/index.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/vendor-index.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/metadata.zip","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/vib20/elxiscsi/EMU_bootbank_elxiscsi_12.0.1188.0-1OEM.670.0.0.8169922.vib","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/vib20/elx-esx-libelxima-8169922.so/ELX_bootbank_elx-esx-libelxima-8169922.so_12.0.1188.0-03.vib","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/metadata.zip/vmware.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/metadata.zip/bulletins/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/metadata.zip/vibs/elx-esx-libelxima-8169922.so-123123855.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/metadata.zip/vibs/elxiscsi-1258413454.xml"],"md5sum":"ca98f9436ce75271d57af62b5c502ee3","name":"cp039935.zip","release":"2019-10-24T19:37:06","revision":"0","sha1sum":"569d731dd3673ac54bb50ac20a47eccdc7f5a7bc","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb358b4ee","20a6e8e4-bf33-4c71-a6bf-d9ecadda42ba"],"type_of_change":"0","version":"2019.12.20","vib_list":[{"name":"elxiscsi","version":"12.0.1188.0-1OEM.670.0.0.8169922"},{"name":"elx-esx-libelxima-8169922.so","version":"12.0.1188.0-03"}]}],"id":{"product":"7cdc9cd1c70149848e6e26c6af8613a5","version":"51005bcbd2fb480a9f049a581ad94152"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE iSCSI Driver for VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"0722","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-11-08T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"elxiscsi:12.0.1188.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"elx-esx-libelxima-8169922.so:12.0.1188.0-03","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]},{"key":"7800374","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"en","x_late":"This package contains utilities and libraries to enable HPE Storage Fibre Channel connectivity on Linux Server for QLogic Host Bus Adapter and Mezzanine Host Bus Adapter"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"2277982","datemodified":"2021-08-27T03:27:32","file_list":["./opt/QLogic_Corporation/qlogic-libs","./opt/QLogic_Corporation/qlogic-libs/README.LIBQLSDM","./opt/QLogic_Corporation/qlogic-libs/libqlsdm-ia32.so","./opt/QLogic_Corporation/qlogic-libs/libqlsdm-ppc64-64bit.so","./opt/QLogic_Corporation/qlogic-libs/libqlsdm-ppc64.so","./opt/QLogic_Corporation/qlogic-libs/libqlsdm-ppc64le.so","./opt/QLogic_Corporation/qlogic-libs/libqlsdm-x86_64.so","./opt/QLogic_Corporation/qlogic-libs/ql-hba-collect-1.12.tgz","./usr/share/smartupdate/HPE-CNA-FC-hpeqlgc-Enablement-Kit/component.xml"],"md5sum":"b960de42e93118a0d764339befc52760","name":"HPE-CNA-FC-hpeqlgc-Enablement-Kit-6.0.0.0-16.noarch.rpm","release":"2021-08-27T03:19:57","revision":"0","sha1sum":"679a228b7b81251d92926e14a29673ea11328c39","size":"2MB","target_guids":[],"type_of_change":"1","version":"6.0.0.0-16"}],"id":{"product":"1de7e811be184880a6d1a5bdf5d60e4a","version":"46532413e35445cf8fdc48df563e2db3"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The Enablement Kit requires that the target environment have the libHBAAPI package installed from your OS installation media.</p>\n\n<p>This version of the enablement kit does not provide the additional functionality of rebuilding the ram disk or setting driver parameters as the previous versions had done.&nbsp; Please refer to the &ldquo;Additional setup&rdquo; section of the Native Linux Device-Mapper Multipath for HPE StorageWorks Arrays reference guide for instructions on how to perform these functions.&nbsp; The reference guide is available at the following link:</p>\n\n<p><a href=\"http://www.hpe.com/storage/spock/\">http://www.hpe.com/storage/spock/</a></p>\n\n<p>Rewrite of same Enablement kit version on SuSE Linux Enterprise Server 12 service pack&nbsp;4 and SuSE Linux Enterprise Server 12 service pack 5 has to be performed using &ndash;force or --replacepkgs with --nodeps option</p>\n\n<p>Example:&nbsp;rpm &ndash;Uvh HPE-CNA-FC-hpeqlgc-Enablement-Kit-&lt;version&gt;.noarch.rpm --force --nodeps</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;rpm &ndash;Uvh HPE-CNA-FC-hpeqlgc-Enablement-Kit-&lt;version&gt;.noarch.rpm --replacepkgs --nodeps</p>\n\n<p>&nbsp;Rewrite of same Enablement kit version on SuSE Linux Enterprise Server 15 service pack&nbsp;1 and SuSE Linux Enterprise Server 15 service pack&nbsp;2 has to be performed using --reinstall option</p>\n\n<p>Example:&nbsp;rpm &ndash;Uvh HPE-CNA-FC-hpeqlgc-Enablement-Kit-&lt;version&gt;.noarch.rpm --force --nodeps</p>\n\n<p>For more information please refer the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic Fibre Channel Enablement Kit for Host Bus Adapter and Mezzanine Host Bus Adapter for Linux"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015D","subven":"1077","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015C","subven":"1077","target_guid":"","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-18T06:47:13","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated the kit to version 6.0.0.0-16</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"HPE-CNA-FC-hpeqlgc-Enablement-Kit","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the vxn driver for HPE Intel ixn 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"837912","datemodified":"2021-02-01T06:57:40","file_list":["cp046080.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll","vxn68x64.cat","vxn68x64.din","vxn68x64.inf","vxn68x64.sys","vxnmsg.dll"],"md5sum":"a8bf21047fa553ccdcc5c939de4b1b48","name":"cp046080.exe","release":"2021-02-01T06:41:04","revision":"0","sha1sum":"1a61822d2db6fe53e74ab64ce32c749ca750f590","size":"818KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec40e07a7c"],"type_of_change":"0","version":"2.1.191.0"}],"id":{"product":"7a409aa1e5444a57b8b10f884c98ae5f","version":"e3e9525cbf9e4cd9a3568ee12f365d20"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel vxn Driver for Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"152E","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d3","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"211B","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c211b","type":"pci","ven":"8086"},{"dev":"1530","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"1515","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c192d","type":"pci","ven":"8086"},{"dev":"1515","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c211a","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product contains Windows system update supported improvements.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">This product now&nbsp; supports the following the network adapters:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>HPE Ethernet 10Gb 2-port 561FLR-T Adapter</li>\n\t<li>HPE Ethernet 10Gb 2-port 561T Adapter</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"vxn68x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built for Red Hat Enterprise Linux 7 (64-bit) to enable the HPE H2xx SAS/SATA Host Bus Adapter.  This RPM provides a customer friendly approach to install a pre-built binary driver."},{"lang":"ja","x_late":"このRPMを使用して、HPE H2xx SAS/SATAホストバスアダプターを有効にする、SRed Hat Enterprise Linux 7（64-bit）用のビルド済みバイナリドライバーモジュールを提供します。  このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"1147503","datemodified":"2018-12-10T07:23:59","file_list":["./etc/modules-load.d/mpt2sas.conf","./lib/modules/3.10.0-862.el7.x86_64","./lib/modules/3.10.0-862.el7.x86_64/extra","./lib/modules/3.10.0-862.el7.x86_64/extra/mpt2sas","./lib/modules/3.10.0-862.el7.x86_64/extra/mpt2sas/mpt2sas.ko","./usr/share/smartupdate/kmod-mpt2sas/component.xml"],"md5sum":"f76ed51dbeac4a6d5fbd31ec0fb8ebca","name":"kmod-mpt2sas-15.10.07.00-3.rhel7u5.x86_64.rpm","release":"2018-12-10T07:24:03","revision":"0","sha1sum":"c394c206e1e9a7c2b4f2240f560523a8ed6d94e0","size":"1MB","target_guids":[],"type_of_change":"1","version":"15.10.09.00-2"},{"bytes":"1156070","datemodified":"2018-12-10T07:25:11","file_list":["./etc/modules-load.d/mpt2sas.conf","./lib/modules/3.10.0-957.el7.x86_64","./lib/modules/3.10.0-957.el7.x86_64/extra","./lib/modules/3.10.0-957.el7.x86_64/extra/mpt2sas","./lib/modules/3.10.0-957.el7.x86_64/extra/mpt2sas/mpt2sas.ko","./usr/share/smartupdate/kmod-mpt2sas/component.xml"],"md5sum":"65efdaf812e018d497c99171a3ffba76","name":"kmod-mpt2sas-15.10.09.00-2.rhel7u6.x86_64.rpm","release":"2018-12-10T07:24:03","revision":"0","sha1sum":"06ef9853199aa335bc3d87052f01ed24a6acaa63","size":"1MB","target_guids":[],"type_of_change":"1","version":"15.10.09.00-2"}],"id":{"product":"528278d2176f4aa5b24b63a8f09b5e95","version":"01a85020813547fb9aed828bab315132"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To install the driver, type the following command:<br />\n# rpm -ivh kmod-mpt2sas-X.X.X.X-X.rhel7uN.x86_64.rpm (x.x.x.x-x represents the version number and N represents the OS Update number)<br />\n<br />\nTo upgrade the driver, type the following command:<br />\n# rpm -Uvh kmod-mpt2sas-X.X.X.X-X.rhel7uN.x86_64.rpm (x.x.x.x-x represents the version number)</p>\n\n<p>A REBOOT is required for your computer when the setup is complete.</p>\n\n<p>Note: If HPE System Insight Manager support is required, install the latest ProLiant Support Pack and kmod-mpt2sas-X.X.X.X-X.rhel7uN.x86_64.rpm after the OS has completed its installation process and system has rebooted.</p>\n"},{"lang":"ja","x_late":"<p>ドライバーをインストールするには、次のコマンドを入力します。<br />\n# rpm -ivh kmod-mpt2sas-X.X.X.X-X.rhel7uN.x86_64.rpm (x.x.x.x-xはバージョン番号を、NはOSアップデート番号を表します。)<br />\n<br />\nドライバーをアップグレードするには、次のコマンドを入力します。<br />\n# rpm -Uvh kmod-mpt2sas-X.X.X.X-X.rhel7xx.x86_64.rpm (x.x.x.x-xはバージョン番号を表します。)</p>\n\n<p>セットアップが完了したらコンピュータをリブートする必要があります。</p>\n\n<p>注: HPE System Insight Managerのサポートが必要な場合、OSのインストールが完了してシステムがリブートした後で、ProLiant用の最新のサービスパックとkmod-mpt2sas-X.X.X.X-X.rhel7uN.x86_64.rpmをインストールします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"LSI Logic Corporation"}],"name":[{"lang":"en","x_late":"HPE H2xx SAS/SATA Host Bus Adapter Driver for Red Hat Enterprise Linux 7 (64-bit)"},{"lang":"ja","x_late":"Red Hat Enterprise Linux 7（64-bit）用HPE H2xx SAS/SATAバスアダプタードライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0070","subdev":"0046","subven":"1590","target_guid":"","type":"pci","ven":"1000"},{"dev":"0087","subdev":"0044","subven":"1590","target_guid":"","type":"pci","ven":"1000"},{"dev":"0087","subdev":"0042","subven":"1590","target_guid":"","type":"pci","ven":"1000"},{"dev":"0087","subdev":"0043","subven":"1590","target_guid":"","type":"pci","ven":"1000"},{"dev":"0087","subdev":"0041","subven":"1590","target_guid":"","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-11-03T09:25:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Address the Linux Spectre Variant 2 Vulnerability Issue</p>\n"},{"curr_enhancements_x_late":"<p>Added support for Red Hat Enterprise Linux 7 Update 6</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"P81","value":"HP ProLiant DL380p Gen8 SE Server"},{"key":"A31","value":"HP ProLiant SL4545 G7 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"P74","value":"HP ProLiant SL140s Gen8 Server (private)"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"P83","value":"HP ProLiant SL210t Gen8 Server"}],"sw_keys":[{"name":"kmod-mpt2sas","sw_key_expectedpath":"software:rpm"},{"name":"kmod-mpt2sas","sw_key_expectedpath":"software:rpm"},{"name":"kmod-mpt2sas","sw_key_expectedpath":"software:rpm"},{"name":"kmod-mpt2sas","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"HPE Dynamic Smart Array controller driver component(hpdsa) for VMware vSphere 6.5, for use with Smart Update Manager."},{"lang":"ja","x_late":"Smart Update Managerとともに使用するためのVMware vSphere 6.5用HPE Dynamic Smartアレイコントローラードライバーコンポーネント（hpdsa）"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"993577","datemodified":"2021-07-14T17:35:53","file_list":["/cp048936.xml","/hpdsa-6.0.0.76-1-offline_bundle-18283990.zip","/hpdsa-6.0.0.76-1-offline_bundle-18283990.zip/index.xml","/hpdsa-6.0.0.76-1-offline_bundle-18283990.zip/vendor-index.xml","/hpdsa-6.0.0.76-1-offline_bundle-18283990.zip/metadata.zip","/hpdsa-6.0.0.76-1-offline_bundle-18283990.zip/vib20/scsi-hpdsa/HPE_bootbank_scsi-hpdsa_6.0.0.76-1OEM.600.0.0.2494585.vib","/hpdsa-6.0.0.76-1-offline_bundle-18283990.zip/metadata.zip/vendor-index.xml","/hpdsa-6.0.0.76-1-offline_bundle-18283990.zip/metadata.zip/vmware.xml","/hpdsa-6.0.0.76-1-offline_bundle-18283990.zip/metadata.zip/bulletins/hpdsa-6.0.0.76-1.xml","/hpdsa-6.0.0.76-1-offline_bundle-18283990.zip/metadata.zip/vibs/scsi-hpdsa--4653470427967347113.xml"],"md5sum":"ff833b90e7138e1be0ec9d97d8d0327a","name":"cp048936.zip","release":"2021-07-14T17:35:08","revision":"0","sha1sum":"bc28984330b627eca82ef839a81c7c2e1c02b858","size":"970KB","target_guids":[],"type_of_change":"1","version":"2021.09.01","vib_list":[{"name":"scsi-hpdsa","version":"6.0.0.76-1OEM.600.0.0.2494585"}]}],"id":{"product":"19bf97ce78cd46209fcfdc12bd9d7a9f","version":"3eabacba8f2f43148f992a384688bb0c"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant</strong></p>\n\n<p><strong>Remote Online:</strong></p>\n\n<ul>\n\t<li>Place the SPP on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\"><u>HPE USB Key Creator Utility</u></a>.</li>\n\t<li>Place the desired driver to be updated in the directory, /SPP20xxxxx/hp/swpackages on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux</li>\n\t<li>CD /hp/swpackages and ./hpsum</li>\n\t<li>Select the next button</li>\n\t<li>Click Add Single Target</li>\n\t<li>Type the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>Follow Smart Update Manager Steps and complete the update.</li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware VUM or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands.</li>\n</ul>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、HPE Service Pack for ProLiantから以下の手順に従ってください</strong></p>\n\n<p><strong>リモートオンライン：</strong></p>\n\n<ul>\n\t<li><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\"><u>HPE USB Key Creator Utility</u></a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの/SPP20xxxxx/hp/swpackagesディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。</li>\n\t<li>CD /hp/swpackagesおよび./hpsum</li>\n\t<li>次へボタンを選択します。</li>\n\t<li>シングルターゲットの追加をクリックします。</li>\n\t<li>更新されるESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ul>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ul>\n\t<li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li>\n\t<li>オフラインバンドルをインストールするために、VMware VUMまたはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ul>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Dynamic Smart Array B140i Controller Driver for VMware vSphere 6.5 (Driver Component)."},{"lang":"ja","x_late":"HPE Dynamic SmartアレイB140iコントローラードライバーfor VMware vSphere 6.5（ドライバーコンポーネント）"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"8D06","subdev":"009C","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"8D66","subdev":"009D","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"A106","subdev":"00C0","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"A107","subdev":"00C0","subven":"1590","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-14T17:22:10","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Fixes an issue where the driver will not upgrade due to the AHCI driver taking priority.</p>\n\n<p>&nbsp;</p>\n\n<p>This issue is only encounter when upgrading to version 2018.09.31 (5.5.0.66-1). All other versions are not affected.</p>\n"},{"curr_enhancements_x_late":"<p>.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"}],"sw_keys":[{"name":"scsi-hpdsa:6.0.0.76-1OEM.550.0.0.1331820","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5790570","datemodified":"2021-06-02T02:06:47","file_list":["./usr/lib/i386-linux-gnu/firmware-system-u23-3.00_2021_04_01-1.1","./usr/lib/i386-linux-gnu/firmware-system-u23-3.00_2021_04_01-1.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-system-u23-3.00_2021_04_01-1.1/.setup","./usr/lib/i386-linux-gnu/firmware-system-u23-3.00_2021_04_01-1.1/CP047381.xml","./usr/lib/i386-linux-gnu/firmware-system-u23-3.00_2021_04_01-1.1/U23_3.00_04_01_2021.signed.flash","./usr/lib/i386-linux-gnu/firmware-system-u23-3.00_2021_04_01-1.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-system-u23-3.00_2021_04_01-1.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP047381.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP047381.scexe"],"md5sum":"1012ea9e8209df133f471c466f1e3037","name":"firmware-system-u23-3.00_2021_04_01-1.1.i386.rpm","release":"2021-06-02T01:58:12","revision":"0","sha1sum":"5a58b9cfff41bd6424b91e10a010ce99c470ee0c","size":"5MB","target_guids":[],"type_of_change":"1","version":"3.00_04-01-2021"}],"id":{"product":"a15fe0bcd3c0422abe0c1c2506d32d09","version":"e2489e0aa15d463fab41f83095d1414f"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HPE ProLiant Agentless Management Service (<strong>AMS</strong>) and HPE SNMP Agents (<strong>SNMP Agents</strong>) are both running.&nbsp; HPE does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager 8.0.0 or later, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、iLOとの通信ができない場合に失敗します。  これは、HPE ProLiant Agentless Management Service (<strong>AMS</strong>)およびHPE SNMPエージェント(<strong>SNMP Agents</strong>)の両方が実行されているときに発生します。  HPEでは、AMSおよびSNMPエージェントを同時に実行させないことを推奨します。  「iLO device not found」エラーが発生した場合、AMSまたはSNMPエージェントを停止させて、再度フラッシュコンポーネントを実行します。<br />\n<br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上のSmart Update Manager 8.0.0以降を使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant ML30 Gen9 (U23) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Linux - HPE ProLiant ML30 Gen9 (U23)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-26T07:15:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode: 0x000000E2 (CPUID 506E3). This Intel microcode patch provide mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-8696 and CVE-2020-8698. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00381. These issues are not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-24512. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-464. The Intel microcode patches included in this release are version 0x000000EA (CPUID 506E3 and CPUID 906E9). These issues are not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel sighting CVE-2020-24512. This security vulnerability is documented in Intel Security Advisory INTEL-SA-00463. The Intel microcode patches included in this release are version 0x000000EA (CPUID 506E3) and 0x000000EA (CPUID 906E9). This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-8670 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"}],"sw_keys":[{"name":"U23","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG1800JFHMH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SEED8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3830-304a46484d48","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: EG1800JFHMH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;EG1800JFHMH Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD7<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3034264","datemodified":"2021-07-24T06:11:09","file_list":["cp048509.xml","cpqsetup.exe","payload.json","setup.dll","T14SEED8.rel"],"md5sum":"45e41a2f3778be17bed60deeeca2f6b8","name":"cp048509.exe","release":"2021-07-24T06:03:05","revision":"0","sha1sum":"4a714ad21a887bac0d8cd35e1dfb9b22f346f1bf","size":"2MB","target_guids":["002340a5-4500-3147-3830-304a46484d48"],"type_of_change":"1","version":"HPD8"}],"id":{"product":"cb2be7d18951448db0daf6ce3cff2a1c","version":"856e89204d034a4da3f91e38db3be942"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG1800JFHMH Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EG1800JFHMHドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG1800JFHMH","target_guid":"002340a5-4500-3147-3830-304a46484d48","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T08:36:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>A low-probability, high severity corner case of sustained outer-diameter activity with emergency power off when heads are at the outer diameter prevented heads from parking/latching properly on a few drives in the field.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG1800JFHMH","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK003840GWSXL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M52004G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-30475753584c","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: VK003840GWSXL Drive"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：VK003840GWSXLドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;&nbsp;VK003840GWSXL Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5009456","datemodified":"2021-07-23T08:54:53","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG3-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG3-2.1/CP048190.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG3-2.1/M52004G3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG3-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048190.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048190.scexe"],"md5sum":"058876447f31018e1c135b3d98e65b3f","name":"firmware-hdd-d1cf327bc4-HPG3-2.1.x86_64.rpm","release":"2021-07-23T08:42:10","revision":"0","sha1sum":"7b9ad6e9268723877b47b62f3b10b645cc0a2a11","size":"4MB","target_guids":["562340a5-304b-3330-3834-30475753584c"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"26ad6199e9ca4196942c2e37e82e08a2","version":"9722a9db66f3424fae82a30d174dec06"},"installation":{"command":"CP040779.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/jp/servers/spp_dl\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK003840GWSXL Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VK003840GWSXLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VK003840GWSXL","target_guid":"562340a5-304b-3330-3834-30475753584c","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T10:11:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Improved Product Quality and Reliability. Changed Cap Charge Timeout to 14 seconds from 4 seconds to provide additional time for cap charge in marginal power environment.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK003840GWSXL","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following storage controllers: Smart Array P230i, P430, P431, P731m, P830i, and P830"},{"lang":"cn","x_late":"该x64智能组件为以下存储控制器提供固件： 智能阵列 P230i、P430、P431、 P731m、P830i 和 P830"},{"lang":"tw","x_late":"此 x64 智慧型元件提供適用於下列儲存控制器的韌體： Smart Array P230i、P430、P431、P731m、P830i 及 P830"},{"lang":"ko","x_late":"이 x64 스마트 구성 요소는 다음과 같은 스토리지 컨트롤러용 펌웨어를 제공합니다. 스마트 어레이 P230i, P430, P431, P731m, P830i, P830"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のストレージコントローラー：SmartアレイP230i, P430, P431, P731m, P830i, およびP830のファームウェアを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for Windows (x64) - Smart Array Smart Array P230i,&nbsp;P430, P431, P731m, P830i, and P830</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;5.02<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;4.54(A)<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 4.10<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; None</p>\n\n<p><strong>Problems Fixed:</strong>&nbsp; &nbsp; &nbsp;</p>\n\n<p>&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4522856","datemodified":"2019-08-08T19:34:34","file_list":["cp039412.xml","cpqsetup.exe","firmware_signed.bin.fw","setup.dll"],"md5sum":"132789cbb848580920360dac59e1f3c5","name":"cp039412.exe","release":"2019-08-08T19:17:06","revision":"0","sha1sum":"cd610b589b2428ac72216bcbe2d1c3df054ea109","size":"4MB","target_guids":[],"type_of_change":"0","version":"5.02"}],"id":{"product":"9aa489b872204af29fd466db29be29fa","version":"7f9840894d3d417c9e7db6d3d61dd138"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActiveIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Smart Array HPCISSS3 Controller Driver version 100.18.2.64 must not be used for firmware update.  Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfd368f11","ServerModel":["*"],"Target_guids":[],"Type":"NE","Version":"100.18.2.64","description":"HPE ProLiant Smart Array HPCISSS3 Controller Driver version 100.18.2.64 must not be used for firmware update.  Update the driver and reboot before attempting firmware update."}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use HP Smart Update Manager from the <a href=\"http://www.hpe.com/info/spp\">HPE </a></strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a><a href=\"http://www.hp.com/go/spp\"> </a><strong>:</strong></strong></p>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\hp\\swpackages</li>\n\t<li>Locate Start.html which is found in the root of the ISO</li>\n\t<li>Open the html file in a supported browser</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>Smartコンポーネントをテンポラリディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>HP Smart Update Managerを使用するには <a href=\"http://www.hpe.com/info/spp\">HPE </a></strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a><a href=\"http://www.hp.com/go/spp\"> </a><strong>:</strong></strong></p>\n\n<p> </p>\n\n<p> </p>\n\n<ul>\n\t<li>ディレクトリ\\SPP20xxxxx\\hp\\swpackagesにアップデートに必要なファームウェアをコピーします</li>\n\t<li>ISOのルートにあるStart.htmlを特定します。</li>\n\t<li>htmlファイルをサポートされているブラウザーで開きます。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows (x64) - Smart Array P230i, P430, P431, P731m, P830i, and P830"},{"lang":"cn","x_late":"Windows (x64)版在线ROM刷新组件 - 智能阵列P230i、P430、P431、P731m、P830i和P830"},{"lang":"tw","x_late":"適用於 Windows (x64) 的線上 ROM 更新元件 - Smart Array P230i、P430、P431、P731m、P830i 與 P830"},{"lang":"ko","x_late":"Windows(x64)용 온라인 ROM 플래시 구성 요소 - 스마트 어레이 P230i, P430, P431, P731m, P830i 및 P830"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows (x64) - SmartアレイP230i、P430、P431、P731m、P830i および P830"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_devices":[{"dev":"323c","subdev":"1928","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1922","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1923","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1926","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1921","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1924","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"1","name":"Microsoft Windows 7 (64-bit) - All Editions","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-05-09T06:05:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Improved Integration with Smart Update Manager</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>The firmware updates could fail while SmartCache is enabled due to active I/O in the Smart Cache.</li>\n\t<li>The serial output of the expander could fail to be populated in the controller logs due to the buffer not being handled appropriately by the controller</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"J06","value":"HP ProLiant MicroServer Gen8"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"P78","value":"HP ProLiant ML310e Gen8 v2 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"}],"sw_keys":[{"name":"1928103c","sw_key_expectedpath":"firmware"},{"name":"1923103c","sw_key_expectedpath":"firmware"},{"name":"1922103c","sw_key_expectedpath":"firmware"},{"name":"1924103c","sw_key_expectedpath":"firmware"},{"name":"1921103c","sw_key_expectedpath":"firmware"},{"name":"1926103c","sw_key_expectedpath":"firmware"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component contains Emulex Storport driver for Extended Systems which provides Fibre Channel over Ethernet-Mezzanine Host Bus Adapter driver support for HPE Blade Storage RAID Arrays."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"2039184","datemodified":"2021-08-27T05:49:11","file_list":["brcmdrvr-fcoe-12.0.1192.0-21.exe","cp048529.xml","cpqsetup.exe","ElxCNAInstaller.dll","install.xml","SysConfig.frm","SysConfig.frm.ja"],"md5sum":"4e020ec2a13c656e321653361fa5c38e","name":"cp048529.exe","release":"2021-08-27T05:46:05","revision":"0","sha1sum":"6d02be61c5dc82c7f66e527d472c09bb2108375f","size":"1MB","target_guids":[],"type_of_change":"1","version":"12.0.1192.0"}],"id":{"product":"e075f8544dbb4d5eb74fec7f8a38a47b","version":"618b3e9618bd4dd080237ea2a01aadfc"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>&nbsp;</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation.</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Storage Mezzanine Fibre Channel Over Ethernet Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"1934","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"1935","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1935","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1934","subven":"103C","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T10:38:39","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p style=\"margin-left:0in; margin-right:0in\">Updated to driver version 12.0.1192.0</p>\n\n<p>&nbsp;</p>\n\n<p>Removed the raw driver file folder.&nbsp; The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:<br />\n<br />\n&nbsp;&nbsp;&nbsp; brcmdrvr-fcoe-version.exe /q2 extract=2<br />\n<br />\nThe extracted files are located:<br />\n<br />\n&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Broadcom\\Drivers\\FCoE-version<br />\n<br />\nEach kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,<br />\n<br />\n&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Broadcom\\Drivers\\FCoE-version\\x64\\win2012</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"elxcna.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"},{"name":"elxcna.sys","sw_key_expectedpath":"%programfiles%\\Broadcom\\AutoPilot Installer\\FCoE\\Drivers\\Storport\\x64\\Win2019"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains be2net drivers for the HPE Emulex 10/20GbE Server Adapters running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Emulex 10/20GbE サーバーアダプター用のbe2net ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"106746","datemodified":"2021-01-14T07:43:04","file_list":["./lib/modules/4.12.14-195-default","./lib/modules/4.12.14-195-default/updates","./lib/modules/4.12.14-195-default/updates/be2net","./lib/modules/4.12.14-195-default/updates/be2net/be2net.ko","./usr/share/smartupdate/be2net-kmp-default/component.xml"],"md5sum":"723c894499a4e8f2aeeef03e668ae96e","name":"be2net-kmp-default-12.0.1342.0_k4.12.14_195-1.sles15sp1.x86_64.rpm","release":"2021-01-14T07:25:04","revision":"0","sha1sum":"272abfb6425aeb7e814dc4e79f20fb672916c16a","size":"104KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecef4cee29"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"105101","datemodified":"2021-01-14T07:33:34","file_list":["./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/be2net","./lib/modules/5.3.18-22-default/updates/be2net/be2net.ko","./usr/share/smartupdate/be2net-kmp-default/component.xml"],"md5sum":"19be9998bd0254ff12efaf23543c5bab","name":"be2net-kmp-default-12.0.1342.0_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-01-14T07:25:04","revision":"0","sha1sum":"abc97fbd076566d3857ac3a440d19f580ddf404e","size":"102KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecef4cee29"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"c08d6e9a714b4bcab51975dad9f3ab91","version":"bdc3c603bf5c470b8f6dd68a72671f8f"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Emulex 10/20GbE Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE Emulex 10/20GbE ドライバー for SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0728","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c220a","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c21d4","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072815908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 12 Service Pack 2</p>\n\n<p>This product now supports elx_net_install.sh&nbsp;installation script to install be2net driver on SUSE Linux Enterprise Server 12 Service Pack 1 or later.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"be2net-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2net-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2net-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2net-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001920KWZQR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173300HPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304b575a5152","Version":"HPK5"},{"DeviceName":"VO003840KWZQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173300HPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304b575a5154","Version":"HPK5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO001920KWZQR and VO003840KWZQT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online NVMe SSD Flash Component for Windows (x64) - VO001920KWZQR and VO003840KWZQT Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"7555776","datemodified":"2021-07-24T08:55:23","file_list":["cp048687.xml","cpqsetup.exe","GP173300HPK5.rel","payload.json","setup.dll"],"md5sum":"5750029cb74fca526fd41bba05e41e56","name":"cp048687.exe","release":"2021-07-24T08:48:04","revision":"0","sha1sum":"bc07c7f60abcc5707ae5bee17112e245db800ef5","size":"7MB","target_guids":["562340a5-304f-3130-3932-304b575a5152","562340a5-304f-3330-3834-304b575a5154"],"type_of_change":"2","version":"HPK5"}],"id":{"product":"f6a0af7aeed5453599816388663b56a0","version":"a29d94b85673418bb8a1d736c44d3a32"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) - VO001920KWZQR and VO003840KWZQT Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - VO001920KWZQRおよびVO003840KWZQTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VO003840KWZQT","target_guid":"562340a5-304f-3330-3834-304b575a5154","type":"nvme"},{"id":"VO001920KWZQR","target_guid":"562340a5-304f-3130-3932-304b575a5152","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-17T09:39:41","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO003840KWZQT","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO001920KWZQR","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ED6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e52","Version":"HPD6"},{"DeviceName":"EG002400JWJNT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ED6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e54","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG001800JWJNR and EG002400JWJNT"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EG001800JWJNRおよびEG002400JWJNT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;EG001800JWJNR and EG002400JWJNT&nbsp;Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong><br />\n&nbsp; &nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4250664","datemodified":"2021-07-24T07:04:21","file_list":["cp048242.xml","cpqsetup.exe","payload.json","setup.dll","SSKYBT512ED6.rel"],"md5sum":"3ff36e899ab3f616cf85b378be3b683e","name":"cp048242.exe","release":"2021-07-24T06:57:04","revision":"0","sha1sum":"ab751649d640b769dc1f11ce3d6f4a5ceaeec13e","size":"4MB","target_guids":["452340a5-3047-3130-3830-304a574a4e52","452340a5-3047-3230-3430-304a574a4e54"],"type_of_change":"1","version":"HPD6"}],"id":{"product":"17b00802f88a41f591cee6102caaf9d2","version":"bb502a54082c4a19a629ac188201e20b"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG001800JWJNR and EG002400JWJNT Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EG001800JWJNRおよびEG002400JWJNTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG001800JWJNR","target_guid":"452340a5-3047-3130-3830-304a574a4e52","type":"sas"},{"id":"EG002400JWJNT","target_guid":"452340a5-3047-3230-3430-304a574a4e54","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-01T11:46:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG002400JWJNT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG001800JWJNR","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for the HPE Emulex 10/20 GbE Server Adapters for Windows Server 2012 R2."},{"lang":"ja","x_late":"このコンポーネントパッケージは、HPE Emulex 10/20GbEサーバーアダプタードライバー for Windows Server 2012 R2を含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"1589824","datemodified":"2020-06-12T10:46:39","file_list":["bepnic.dll","bepnic.rtf","cp044540.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll","occfg.exe","ocnd64.cat","ocnd64.inf","ocnd64.sys"],"md5sum":"0d94a80e865a3ae659c8dcb2dd273d49","name":"cp044540.exe","release":"2020-06-12T10:33:05","revision":"0","sha1sum":"9f5c08a08ca75a06c423d78f294dd553e349399d","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec173970a5"],"type_of_change":"0","version":"12.0.1195.0"}],"id":{"product":"ab8b689939f94b78976081b76f12fa41","version":"b277a830033240b4a5a985cfb14cfe76"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex 10/20 GbE Driver for Windows Server 2012 R2"},{"lang":"ja","x_late":"HPE Emulex 10/20 GbEドライバー for Windows Server 2012 R2"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"0728","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c220a","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c21d4","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072815908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-11T01:46:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now remove&nbsp;supports Synergy and Blade&nbsp;Server.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"}],"sw_keys":[{"name":"ocnd64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB002000JWFVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATRsnSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a5746564e","Version":"HPD4"},{"DeviceName":"MB004000JWFVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATRsnSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a57465650","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB002000JWFVN and MB004000JWFVP"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB002000JWFVNおよびMB004000JWFVP"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB002000JWFVN and MB004000JWFVP Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"16247490","datemodified":"2021-08-30T19:26:17","file_list":["/CP048318_BUILD_2.data","/CP048318.vmexe","/CP048318.vmexe64","/CP048318.vmfile","/CP048318_VMw.zip","/CP048318.xml","/payload.json","/CP048318_VMw.zip/index.xml","/CP048318_VMw.zip/vendor-index.xml","/CP048318_VMw.zip/metadata.zip","/CP048318_VMw.zip/vib20/CP048318/HPE_bootbank_CP048318_HPD4.2-7.0.0.15843807.vib","/CP048318_VMw.zip/metadata.zip/vendor-index.xml","/CP048318_VMw.zip/metadata.zip/vmware.xml","/CP048318_VMw.zip/metadata.zip/vibs/CP048318--763999349046404700.xml","/CP048318_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048318_HPD4.2-7.0.0.15843807.xml"],"md5sum":"a5966c7728f7237a4e37084c0f5adc5a","name":"CP048318.zip","release":"2021-08-30T19:21:03","revision":"0","sha1sum":"1011cd4f7cdd4772d559ef14236feed0603fb40b","size":"15MB","target_guids":["4d2340a5-3042-3230-3030-304a5746564e","4d2340a5-3042-3430-3030-304a57465650"],"type_of_change":"1","version":"HPD4","vib_list":[{"name":"CP048318","version":"HPD4.2-7.0.0.15843807"}]}],"id":{"product":"640faf1092b548cf896ce4ae4d6b3ae8","version":"88d844cee8174d70be98e050daa024bd"},"installation":{"command":"CP041752.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>HP Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - MB002000JWFVN and MB004000JWFVP Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - MB002000JWFVNおよびMB004000JWFVPドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB002000JWFVN","target_guid":"4d2340a5-3042-3230-3030-304a5746564e","type":"sas"},{"id":"MB004000JWFVP","target_guid":"4d2340a5-3042-3430-3030-304a57465650","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-04T10:15:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware provides a change to the Vendor ID in the VPD page that refers to HP instead of HPE.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB002000JWFVN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB004000JWFVP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300100","languages":[{"lang":"fr","x_late":"Pilote - Stockage"},{"lang":"en","x_late":"Driver - Storage"},{"lang":"cn","x_late":"驱动程序 - 存储"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置"},{"lang":"de","x_late":"Treiber - Speicher"},{"lang":"ko","x_late":"드라이버 - 스토리지"},{"lang":"it","x_late":"Driver - Memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ"},{"lang":"es","x_late":"Controlador - Almacenamiento"}]}],"description":[{"lang":"en","x_late":"This driver provides Windows 2012/2012 R2 x64, Windows server 2016/2019 support for:\n Dynamic Smart Array B140i Controller."},{"lang":"ja","x_late":"このドライバーは、Windows 2012/2012 R2 x64およびWindows Server 2016/2019サポートを提供します。Dynamic SmartアレイB140iコントローラー。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[],"files":[{"bytes":"1430104","datemodified":"2020-02-27T14:20:52","file_list":["cp042594.xml","cpqsetup.exe","generic.dll","HPpSA.sys","hpsa3.cat","HPSA3.inf","Hpsa3.sys","hpsa3co002.dll","install.xml","libsa3.sys"],"md5sum":"a598c94b88b84be9ef2d454a519473d4","name":"cp042594.exe","release":"2020-02-27T14:19:07","revision":"0","sha1sum":"f74f2703dd0baf180c36079e4a3c165e79b642bd","size":"1MB","target_guids":[],"type_of_change":"1","version":"62.16.2.64"}],"id":{"product":"78fc77876f754f93b5ef96248fa664b1","version":"ae53a398a9c74968aef2d220f2d67d15"},"installation":{"command":"cpqsetup.exe","command_params":"/verbose_log","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Place the Smart Component in a temporary directory, then double-click it to run.</p>\n\n<p>Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.</p>\n\n<p>Click the &quot;Install&quot; button to perform the driver installation.</p>\n\n<p><strong>Note:&nbsp;</strong>Per Microsoft kb #2031031(<a href=\"https://support.microsoft.com/en-us/kb/2931031\">https://support.microsoft.com/en-us/kb/2931031</a>), users cannot remove/unmount a USB until after the install has finished.</p>\n"},{"lang":"ja","x_late":"<p>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。</p>\n\n<p>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。</p>\n\n<p>インストールボタンをクリックしてドライバーインストールを実行します。</p>\n\n<p><strong>注： </strong>Microsoft kb #2031031について(<a href=\"https://support.microsoft.com/en-us/kb/2931031\">https://support.microsoft.com/en-us/kb/2931031</a>), ユーザーはUSB インストールが終わるまではUSBを削除したり、取り外したりすることはできません。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Dynamic Smart Array B140i Controller Driver for 64-bit Microsoft Windows Server 2012/2012 R2/2016/2019 Editions"},{"lang":"ja","x_late":"Dynamic SmartアレイB140iコントローラードライバーfor 64ビットMicrosoft Windows Server 2012/2012 R2/2016/2019 Editions"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"A107","subdev":"00C0","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"A106","subdev":"00C0","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"8D66","subdev":"009D","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"8D06","subdev":"009C","subven":"1590","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Storage Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-01-04T09:20:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Improved integration with Smart Update Manager.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Fix error handling of AHCI reported Fatal errors with NCQ and Non-NCQ commands in SATL potentially causing RAID stack timeouts and excessive read/write command timeouts leading to SCSI bus reset with M.2 SSD drives configured with SW RAID.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"","value":"HP SL6700 Chassis"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U25","value":"HP ProLiant XL280d Accelerator Tray - cancelled"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"hpsa3.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000400JWUFT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57554654","Version":"HPD3"},{"DeviceName":"MO000800JWUFU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57554655","Version":"HPD3"},{"DeviceName":"MO001600JWUFV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57554656","Version":"HPD3"},{"DeviceName":"MO003200JWUGA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57554741","Version":"HPD3"},{"DeviceName":"MO006400JWUGB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a57554742","Version":"HPD3"},{"DeviceName":"EO000400JWUGC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57554743","Version":"HPD3"},{"DeviceName":"EO000800JWUGD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57554744","Version":"HPD3"},{"DeviceName":"EO001600JWUGE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57554745","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MO000400JWUFT、MO000800JWUFU、MO001600JWUFV、MO003200JWUGA、MO006400JWUGB、EO000400JWUGC、EO000800JWUGD、およびEO001600JWUGE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD1<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3388568","datemodified":"2021-07-25T17:44:46","file_list":["cp048628.xml","cpqsetup.exe","hbcpssssefd3.rel","payload.json","setup.dll"],"md5sum":"d6324da8b6a43e5a4232ac6b7ab9da3c","name":"cp048628.exe","release":"2021-07-25T17:37:04","revision":"0","sha1sum":"d8e9a4555259977c644a19cda1eaaf86a10bd3c3","size":"3MB","target_guids":["4d2340a5-304f-3030-3430-304a57554654","4d2340a5-304f-3030-3830-304a57554655","4d2340a5-304f-3130-3630-304a57554656","4d2340a5-304f-3330-3230-304a57554741","4d2340a5-304f-3630-3430-304a57554742","452340a5-304f-3030-3430-304a57554743","452340a5-304f-3030-3830-304a57554744","452340a5-304f-3130-3630-304a57554745"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"dab6093d4d7545e892501476a1f6d448","version":"159b88bd8d61468085aeab0d4ce3d5b4"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MO000400JWUFT、MO000800JWUFU、MO001600JWUFV、MO003200JWUGA、MO006400JWUGB、EO000400JWUGC、EO000800JWUGD、およびEO001600JWUGEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MO006400JWUGB","target_guid":"4d2340a5-304f-3630-3430-304a57554742","type":"sas"},{"id":"MO003200JWUGA","target_guid":"4d2340a5-304f-3330-3230-304a57554741","type":"sas"},{"id":"MO001600JWUFV","target_guid":"4d2340a5-304f-3130-3630-304a57554656","type":"sas"},{"id":"EO001600JWUGE","target_guid":"452340a5-304f-3130-3630-304a57554745","type":"sas"},{"id":"MO000800JWUFU","target_guid":"4d2340a5-304f-3030-3830-304a57554655","type":"sas"},{"id":"EO000800JWUGD","target_guid":"452340a5-304f-3030-3830-304a57554744","type":"sas"},{"id":"MO000400JWUFT","target_guid":"4d2340a5-304f-3030-3430-304a57554654","type":"sas"},{"id":"EO000400JWUGC","target_guid":"452340a5-304f-3030-3430-304a57554743","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T13:45:27","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EO000800JWUGD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200JWUGA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO001600JWUGE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000400JWUGC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600JWUFV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000400JWUFT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800JWUFU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO006400JWUGB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400PXDBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AL4HPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-305058444251","Version":"HPD1"},{"DeviceName":"EO000800PXDCK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AL4HPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-30505844434b","Version":"HPD1"},{"DeviceName":"EO001600PXDCH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AL4HPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-305058444348","Version":"HPD1"},{"DeviceName":"MO000800PXDBP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AL4HPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-305058444250","Version":"HPD1"},{"DeviceName":"MO001600PXDCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AL4HPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-305058444343","Version":"HPD1"},{"DeviceName":"MO003200PXDCD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AL4HPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-305058444344","Version":"HPD1"},{"DeviceName":"MO006400PXDCE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AL4HPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-305058444345","Version":"HPD1"},{"DeviceName":"VO000960PXDBN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AL4HPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-30505844424e","Version":"HPD1"},{"DeviceName":"VO001920PXDBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AL4HPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-305058444252","Version":"HPD1"},{"DeviceName":"VO003840PXDBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AL4HPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-305058444254","Version":"HPD1"},{"DeviceName":"VO007680PXDBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AL4HPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-305058444255","Version":"HPD1"},{"DeviceName":"VO015300PXDBV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AL4HPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3330-305058444256","Version":"HPD1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"17674764","datemodified":"2021-08-30T05:24:32","file_list":["/CP049165_BUILD_2.data","/CP049165.vmexe","/CP049165.vmexe64","/CP049165.vmfile","/CP049165_VMw.zip","/CP049165.xml","/payload.json","/CP049165_VMw.zip/index.xml","/CP049165_VMw.zip/vendor-index.xml","/CP049165_VMw.zip/metadata.zip","/CP049165_VMw.zip/vib20/CP049165/HPE_bootbank_CP049165_HPD1.2-7.0.0.15843807.vib","/CP049165_VMw.zip/metadata.zip/vendor-index.xml","/CP049165_VMw.zip/metadata.zip/vmware.xml","/CP049165_VMw.zip/metadata.zip/vibs/CP049165--2003020224906751326.xml","/CP049165_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049165_HPD1.2-7.0.0.15843807.xml"],"md5sum":"d47062d99be63bc3042a88a7316a6932","name":"CP049165.zip","release":"2021-08-30T05:19:28","revision":"0","sha1sum":"b4504899448b3fefa5f3aa1c8e38797327e0823d","size":"16MB","target_guids":["452340a5-304f-3030-3430-305058444251","452340a5-304f-3030-3830-30505844434b","452340a5-304f-3130-3630-305058444348","4d2340a5-304f-3030-3830-305058444250","4d2340a5-304f-3130-3630-305058444343","4d2340a5-304f-3330-3230-305058444344","4d2340a5-304f-3630-3430-305058444345","562340a5-304f-3030-3936-30505844424e","562340a5-304f-3130-3932-305058444252","562340a5-304f-3330-3834-305058444254","562340a5-304f-3730-3638-305058444255","562340a5-304f-3531-3330-305058444256"],"type_of_change":"1","version":"HPD1","vib_list":[{"name":"CP049165","version":"HPD1.2-7.0.0.15843807"}]}],"id":{"product":"cd1eb2802ed24b6aa04d98effb166b0e","version":"4fe9e8b4000b42ae8ed5fff672cfab6b"},"installation":{"command":"CP042550.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV  Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EO000800PXDCK","target_guid":"452340a5-304f-3030-3830-30505844434b","type":"sas"},{"id":"MO000800PXDBP","target_guid":"4d2340a5-304f-3030-3830-305058444250","type":"sas"},{"id":"EO000400PXDBQ","target_guid":"452340a5-304f-3030-3430-305058444251","type":"sas"},{"id":"EO001600PXDCH","target_guid":"452340a5-304f-3130-3630-305058444348","type":"sas"},{"id":"MO001600PXDCC","target_guid":"4d2340a5-304f-3130-3630-305058444343","type":"sas"},{"id":"MO006400PXDCE","target_guid":"4d2340a5-304f-3630-3430-305058444345","type":"sas"},{"id":"VO007680PXDBU","target_guid":"562340a5-304f-3730-3638-305058444255","type":"sas"},{"id":"VO001920PXDBR","target_guid":"562340a5-304f-3130-3932-305058444252","type":"sas"},{"id":"VO015300PXDBV","target_guid":"562340a5-304f-3531-3330-305058444256","type":"sas"},{"id":"MO003200PXDCD","target_guid":"4d2340a5-304f-3330-3230-305058444344","type":"sas"},{"id":"VO000960PXDBN","target_guid":"562340a5-304f-3030-3936-30505844424e","type":"sas"},{"id":"VO003840PXDBT","target_guid":"562340a5-304f-3330-3834-305058444254","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-27T16:33:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Firmware&nbsp;release to enable SAS4.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO007680PXDBU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO001600PXDCH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920PXDBR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000800PXDCK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200PXDCD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003840PXDBT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO015300PXDBV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000960PXDBN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600PXDCC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000400PXDBQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO006400PXDCE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800PXDBP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWKGR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574b4752","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB006000GWKGR"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong></p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB006000GWKGR Drive</p>\n\n<p><strong>Release Version and/or Date:</strong></p>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong></p>\n\n<p><strong>&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Previous Version of Firmware:</strong></p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp; &nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"18762720","datemodified":"2021-08-30T20:09:27","file_list":["/CP048329_BUILD_2.data","/CP048329.vmexe","/CP048329.vmexe64","/CP048329.vmfile","/CP048329_VMw.zip","/CP048329.xml","/payload.json","/CP048329_VMw.zip/index.xml","/CP048329_VMw.zip/vendor-index.xml","/CP048329_VMw.zip/metadata.zip","/CP048329_VMw.zip/vib20/CP048329/HPE_bootbank_CP048329_HPG1.2-7.0.0.15843807.vib","/CP048329_VMw.zip/metadata.zip/vendor-index.xml","/CP048329_VMw.zip/metadata.zip/vmware.xml","/CP048329_VMw.zip/metadata.zip/vibs/CP048329--3175177974414532236.xml","/CP048329_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048329_HPG1.2-7.0.0.15843807.xml"],"md5sum":"126f0d55eed46bc36e3e8293f2739441","name":"CP048329.zip","release":"2021-08-30T20:04:12","revision":"0","sha1sum":"e9c4c11c595c5f3217e73d717ece0d77b22c09a9","size":"17MB","target_guids":["4d2340a5-3042-3630-3030-3047574b4752"],"type_of_change":"1","version":"HPG1","vib_list":[{"name":"CP048329","version":"HPG1.2-7.0.0.15843807"}]}],"id":{"product":"cfe4c5a213fb4be397a8b588efd29cc1","version":"361c18f57f1544ebab567b539fbe2354"},"installation":{"command":"CP041520.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB006000GWKGR Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB006000GWKGR ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB006000GWKGR","target_guid":"4d2340a5-3042-3630-3030-3047574b4752","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-05T18:18:43","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000GWKGR","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWJRR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06ACHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574a5252","Version":"HPG4"},{"DeviceName":"MB008000GWJRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06ACHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-3047574a5254","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB006000GWJRR and MB008000GWJRT"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB006000GWJRRおよびMB008000GWJRT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for&nbsp;Windows (x64)&nbsp;-&nbsp;MB006000GWJRR and MB008000GWJRT Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3027392","datemodified":"2021-07-26T05:59:27","file_list":["cp048470.xml","cpqsetup.exe","payload.json","setup.dll","TAMG06ACHPG4.REL"],"md5sum":"0b43c4503a90a2765387542c02792016","name":"cp048470.exe","release":"2021-07-26T05:51:04","revision":"0","sha1sum":"cbcf28cf25bcea74d367fb0459d853da50f0be5d","size":"2MB","target_guids":["4d2340a5-3042-3630-3030-3047574a5252","4d2340a5-3042-3830-3030-3047574a5254"],"type_of_change":"1","version":"HPG4"}],"id":{"product":"e94dfd89626f4fc992d59a1c00e08f54","version":"66b693e4cf724bd6bb2271d2e8785032"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB006000GWJRR and MB008000GWJRT Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB006000GWJRRおよびMB008000GWJRTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB008000GWJRT","target_guid":"4d2340a5-3042-3830-3030-3047574a5254","type":"sata"},{"id":"MB006000GWJRR","target_guid":"4d2340a5-3042-3630-3030-3047574a5252","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T14:06:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000GWJRR","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB008000GWJRT","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG0300JEHLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFLRCD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3330-304a45484c56","Version":"HPD5"},{"DeviceName":"EG0600JEHMA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFLRCD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3630-304a45484d41","Version":"HPD5"},{"DeviceName":"EG0900JEHMB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFLRCD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3930-304a45484d42","Version":"HPD5"},{"DeviceName":"EG1200JEHMC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFLRCD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3230-304a45484d43","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG0300JEHLV, EG0600JEHMA, EG0900JEHMB, and EG1200JEHMC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG0300JEHLV, EG0600JEHMA, EG0900JEHMB&nbsp;and&nbsp; EG1200JEHMC Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD3</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;&nbsp; None.&nbsp;</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;&nbsp; None.</p>\n"}],"files":[{"bytes":"5525650","datemodified":"2021-07-23T08:29:04","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-31f91b8622-HPD5-9.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-31f91b8622-HPD5-9.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-31f91b8622-HPD5-9.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-31f91b8622-HPD5-9.1/CP048076.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-31f91b8622-HPD5-9.1/HCFLRCD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-31f91b8622-HPD5-9.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-31f91b8622-HPD5-9.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-31f91b8622-HPD5-9.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-31f91b8622-HPD5-9.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048076.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048076.scexe"],"md5sum":"73c5aaba3505f2df273689ffd19a46fd","name":"firmware-hdd-31f91b8622-HPD5-9.1.x86_64.rpm","release":"2021-07-23T08:16:17","revision":"0","sha1sum":"3307c2296f58b07dbb4aeb3bdf0fdc70ef383f0b","size":"5MB","target_guids":["002340a5-4500-3047-3330-304a45484c56","002340a5-4500-3047-3630-304a45484d41","002340a5-4500-3047-3930-304a45484d42","002340a5-4500-3147-3230-304a45484d43"],"type_of_change":"1","version":"HPD5"}],"id":{"product":"99e0afc9d35746928c6cb34efe0c36a4","version":"bda08628ff654746934d77e40b60fe5c"},"installation":{"command":"CP040314.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EG0300JEHLV, EG0600JEHMA, EG0900JEHMB and EG1200JEHMC Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - EG0300JEHLV、EG0600JEHMA、EG0900JEHMB、およびEG1200JEHMCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"EG1200JEHMC","target_guid":"002340a5-4500-3147-3230-304a45484d43","type":"sas"},{"id":"EG0300JEHLV","target_guid":"002340a5-4500-3047-3330-304a45484c56","type":"sas"},{"id":"EG0600JEHMA","target_guid":"002340a5-4500-3047-3630-304a45484d41","type":"sas"},{"id":"EG0900JEHMB","target_guid":"002340a5-4500-3047-3930-304a45484d42","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T10:43:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG0900JEHMB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG1200JEHMC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0600JEHMA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0300JEHLV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK003840GWHTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M51004G8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-304757485445","Version":"HPG8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MK003840GWHTE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;&nbsp;(x64)&nbsp;- MK003840GWHTE Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG6<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG6</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3108280","datemodified":"2021-07-25T16:30:42","file_list":["cp048620.xml","cpqsetup.exe","M51004G8.rel","payload.json","setup.dll"],"md5sum":"f3f082f88d17bb0d831f8ce85a4f2c2f","name":"cp048620.exe","release":"2021-07-25T16:23:04","revision":"0","sha1sum":"2003ea61b6111d133283bb4fad72aedd91b5c1d5","size":"2MB","target_guids":["4d2340a5-304b-3330-3834-304757485445"],"type_of_change":"1","version":"HPG8"}],"id":{"product":"97296584dde64484806a51651325b7a3","version":"6823d27c2a74446c8c6f2f796766844c"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MK003840GWHTE Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MK003840GWHTEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T12:44:07","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Improvements to Product Quality and Reliability.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK003840GWHTE","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"本產品包含 SUSE Linux Enterprise Server 12 x86_64 下執行的 HPE Intel ixgbe 乙太網路 NIC 驅動程式。"},{"lang":"en","x_late":"This product contains the drivers for the HPE Intel ixgbe Ethernet NICs running under SUSE Linux Enterprise Server 12 x86_64."},{"lang":"ko","x_late":"이 제품에는 SUSE Linux Enterprise Server 12 x86_64에서 실행 중인 HPE Intel ixgbe 이더넷 NIC용 드라이버가 포함되어 있습니다."},{"lang":"cn","x_late":"本产品包含适用于在 SUSE Linux Enterprise Server 12 x86_64 下方运行的 HPE Intel ixgbe 以太网网卡驱动程序。"},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12 x86_64で動作するHPE Intel ixgbe Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"4099519","datemodified":"2021-01-09T01:39:40","file_list":["./etc/depmod.d/hp-ixgbe.conf","./etc/dracut.conf.d/hp-ixgbe-oob.conf","./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/hp-ixgbe","./lib/modules/4.12.14-94.41-default/updates/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/hp-ixgbe-kmp-default/component.xml"],"md5sum":"0bcb2e1b8f6bc6a7d89191d8f3c35abe","name":"hp-ixgbe-kmp-default-5.9.4_k4.12.14_94.41-1.sles12sp4.x86_64.rpm","release":"2021-01-09T01:29:05","revision":"0","sha1sum":"2c2e7889f03dd48f7fd63b00e389b691cfc7a6c7","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec22d08a36"],"type_of_change":"0","version":"5.9.4-1"},{"bytes":"4216415","datemodified":"2021-01-09T01:35:56","file_list":["./etc/depmod.d/hp-ixgbe.conf","./etc/dracut.conf.d/hp-ixgbe-oob.conf","./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/hp-ixgbe","./lib/modules/4.12.14-120-default/updates/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/hp-ixgbe-kmp-default/component.xml"],"md5sum":"0a1109a8720d402c1ef70378ce2a8e8b","name":"hp-ixgbe-kmp-default-5.9.4_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-01-09T01:29:05","revision":"0","sha1sum":"bc8838c6ddbf850ce4504e33bd99a566bb17fbe5","size":"4MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec22d08a36"],"type_of_change":"0","version":"5.9.4-1"}],"id":{"product":"926b8a90acf147dd8614685a9453a0ed","version":"1dab5bf9eb75410999037da04153edc7"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>Download README for any additional installation instructions.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 SUSE Linux Enterprise Server 12 x86_64 的 HPE Intel ixgbe 驅動程式"},{"lang":"en","x_late":"HPE Intel ixgbe Drivers for SUSE Linux Enterprise Server 12 x86_64"},{"lang":"ko","x_late":"SUSE Linux Enterprise Server 12 x86_64용 HPE Intel ixgbe 드라이버"},{"lang":"cn","x_late":"适用于 SUSE Linux Enterprise Server 12 x86_64 的 HPE Intel ixgbe 驱动程序"},{"lang":"ja","x_late":"HPE Intel ixgbeドライバー for SUSE Linux Enterprise Server 12 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c192d","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c211a","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"},{"dev":"152E","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d3","type":"pci","ven":"8086"},{"dev":"1530","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"1515","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c192d","type":"pci","ven":"8086"},{"dev":"1515","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c211a","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product update Linux kernel documentation and Configure IRQ affinity tools</p>\n","latest_fixes_x_late":"<p>This product corrects an issue which errata kernel loads inbox driver instead of this component after booting into OS</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>This product enhances reliability via adding support for new mailbox communication between PF(Physical Function) and VF(Virtual Function) and remove its potential flaws that may lead to the undefined or faulty behavior</li>\n\t<li>This product enhances compatibility where new mailbox api implementation is alo compatible with old drivers</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"hp-ixgbe-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbe-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbe-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbe-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under Red Hat Enterprise Linux 7 Update 9 x86_64."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"24697","datemodified":"2021-02-11T00:28:19","file_list":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib64/libbnxt_re-218.0.7.0.so","./usr/lib64/libbnxt_re-rdmav22.so","./usr/lib64/libbnxt_re.so","./usr/share/smartupdate/libbnxt_re/component.xml"],"md5sum":"1daeba3a63d6f205d1e6a31ab2020f57","name":"libbnxt_re-218.0.7.0-rhel7u9.x86_64.rpm","release":"2021-02-11T00:25:03","revision":"0","sha1sum":"d683f7c71346c45dccca5a39ec6b836b47cb112b","size":"24KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"type_of_change":"0","version":"218.0.7.0"}],"id":{"product":"1ff674590ea54295a0a402207a50999a","version":"8a623fc47ccb4689921f70c98423a92e"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"text-align:left\">rpm -ivh &lt;bnxt_rooce &gt;.rpm --force [--replacefiles]</p>\n\n<p style=\"text-align:left\">Use --force or --replacefiles options while installing or updating the HPE Broadcom RoCE library which may conflict with inbox library</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E RoCE Library for Red Hat Enterprise Linux 7 Update 9"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"libbnxt_re","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH0300JDXBA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SXD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3330-304a44584241","Version":"HPD5"},{"DeviceName":"EH0450JDXBB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SXD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3435-304a44584242","Version":"HPD5"},{"DeviceName":"EH0600JDXBC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SXD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3630-304a44584243","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EH0300JDXBA, EH0450JDXBB, and EH0600JDXBC"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： EH0300JDXBA、EH0450JDXBB、およびEH0600JDXBC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - EH0300JDXBA, EH0450JDXBB&nbsp;and EH0600JDXBC Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features</strong>:</p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"2912280","datemodified":"2021-07-24T05:38:50","file_list":["cp048517.xml","cpqsetup.exe","payload.json","setup.dll","TA13SXD5.rel"],"md5sum":"f659aec23bf26507dd18a204bc4807fb","name":"cp048517.exe","release":"2021-07-24T05:30:04","revision":"0","sha1sum":"a17ca04f46055ce25f97d7e104ea90d8ddd2e62b","size":"2MB","target_guids":["002340a5-4500-3048-3330-304a44584241","002340a5-4500-3048-3435-304a44584242","002340a5-4500-3048-3630-304a44584243"],"type_of_change":"1","version":"HPD5"}],"id":{"product":"8de9ca424f8f4678aeecd66cdfe60068","version":"69df212698564e33ba12d5fa33f07e47"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EH0300JDXBA, EH0450JDXBB and EH0600JDXBC Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows(x64)- EH0300JDXBA、EH0450JDXBB、およびEH0600JDXBCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EH0300JDXBA","target_guid":"002340a5-4500-3048-3330-304a44584241","type":"sas"},{"id":"EH0450JDXBB","target_guid":"002340a5-4500-3048-3435-304a44584242","type":"sas"},{"id":"EH0600JDXBC","target_guid":"002340a5-4500-3048-3630-304a44584243","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T09:58:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH0450JDXBB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0300JDXBA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0600JDXBC","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"LO0400KEFJQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-304f-3430-304b45464a51","Version":"HPK4"},{"DeviceName":"LO0800KEFJR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-304f-3830-304b45464a52","Version":"HPK4"},{"DeviceName":"LO1600KEFJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-314f-3630-304b45464a54","Version":"HPK4"},{"DeviceName":"LO2000KEFJU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-324f-3030-304b45464a55","Version":"HPK4"},{"DeviceName":"LT0800KEXVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-3054-3830-304b45585641","Version":"HPK4"},{"DeviceName":"LT1600KEXVB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-3154-3630-304b45585642","Version":"HPK4"},{"DeviceName":"LT2000KEXVC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-3254-3030-304b45585643","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: LO0400KEFJQ, LO0800KEFJR, LO1600KEFJT, LO2000KEFJU, LT0800KEXVA, LT1600KEXVB and LT2000KEXVC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; Online NVMe SSD Flash Component for VMware ESXi - LO0400KEFJQ, LO0800KEFJR, LO1600KEFJT, LO2000KEFJU, LT0800KEXVA, LT1600KEXVB, and LT2000KEXVC Drives</p>\n\n<p><br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp; HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; &nbsp;None</p>\n"}],"files":[{"bytes":"16036520","datemodified":"2021-08-26T05:58:35","file_list":["/CP045718_BUILD_4.data","/CP045718.vmexe","/CP045718.vmexe64","/CP045718.vmfile","/CP045718_VMw.zip","/CP045718.xml","/payload.json","/CP045718_VMw.zip/index.xml","/CP045718_VMw.zip/vendor-index.xml","/CP045718_VMw.zip/metadata.zip","/CP045718_VMw.zip/vib20/CP045718/HPE_bootbank_CP045718_HPK4.4-7.0.0.15843807.vib","/CP045718_VMw.zip/metadata.zip/vendor-index.xml","/CP045718_VMw.zip/metadata.zip/vmware.xml","/CP045718_VMw.zip/metadata.zip/vibs/CP045718--7474043012750851602.xml","/CP045718_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045718_HPK4.4-7.0.0.15843807.xml"],"md5sum":"0b3ecedd34b46c7d354d614a8c63aba2","name":"CP045718.zip","release":"2021-08-26T05:52:38","revision":"0","sha1sum":"ab3959580fa9e2cb8b1acfb196077ef363dc42db","size":"15MB","target_guids":["002340a5-4c00-304f-3430-304b45464a51","002340a5-4c00-304f-3830-304b45464a52","002340a5-4c00-314f-3630-304b45464a54","002340a5-4c00-324f-3030-304b45464a55","002340a5-4c00-3054-3830-304b45585641","002340a5-4c00-3154-3630-304b45585642","002340a5-4c00-3254-3030-304b45585643"],"type_of_change":"1","version":"HPK4","vib_list":[{"name":"CP045718","version":"HPK4.4-7.0.0.15843807"}]}],"id":{"product":"dea3d95c6cc64119ac507d9a05278db0","version":"06aa16d93ec74d40bc7bb7ea0855d979"},"installation":{"command":"CP036934.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi - LO0400KEFJQ, LO0800KEFJR, LO1600KEFJT, LO2000KEFJU, LT0800KEXVA, LT1600KEXVB, and LT2000KEXVC Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - LO0400KEFJQ、LO0800KEFJR、LO1600KEFJT、LO2000KEFJU、LT0800KEXVA、LT1600KEXVB、およびLT2000KEXVCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"LT0800KEXVA","target_guid":"002340a5-4c00-3054-3830-304b45585641","type":"nvme"},{"id":"LT1600KEXVB","target_guid":"002340a5-4c00-3154-3630-304b45585642","type":"nvme"},{"id":"LT2000KEXVC","target_guid":"002340a5-4c00-3254-3030-304b45585643","type":"nvme"},{"id":"LO2000KEFJU","target_guid":"002340a5-4c00-324f-3030-304b45464a55","type":"nvme"},{"id":"LO0400KEFJQ","target_guid":"002340a5-4c00-304f-3430-304b45464a51","type":"nvme"},{"id":"LO0800KEFJR","target_guid":"002340a5-4c00-304f-3830-304b45464a52","type":"nvme"},{"id":"LO1600KEFJT","target_guid":"002340a5-4c00-314f-3630-304b45464a54","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:47:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"LO0400KEFJQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LO1600KEFJT","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LT2000KEXVC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LO0800KEFJR","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LT0800KEXVA","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LT1600KEXVB","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LO2000KEFJU","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"本產品包含 SUSE Linux Enterprise Server 12 x86_64 下執行的 HPE Intel ixgbe 乙太網路 NIC 之 SRIOV 虛擬功能驅動程式。"},{"lang":"en","x_late":"This product contains the SRIOV virtual function drivers for the HPE Intel ixgbe Ethernet NICs running under SUSE Linux Enterprise Server 12 x86_64."},{"lang":"ko","x_late":"이 제품에는 SUSE Linux Enterprise Server 12 x86_64에서 실행되는 HPE Intel ixgbe 이더넷 NIC용 SRIOV 가상 기능 드라이버가 포함되어 있습니다."},{"lang":"cn","x_late":"本产品包含适用于在 SUSE Linux Enterprise Server 12 x86_64 下方运行的 HPE Intel ixgbe 以太网网卡 SRIOV 虚拟功能驱动程序。"},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12 x86_64で動作するHPE Intel ixgbe Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1054791","datemodified":"2021-01-09T00:30:27","file_list":["./etc/depmod.d/hp-ixgbevf.conf","./etc/dracut.conf.d/hp-ixgbevf-oob.conf","./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/hp-ixgbevf","./lib/modules/4.12.14-120-default/updates/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/hp-ixgbevf-kmp-default/component.xml"],"md5sum":"eef03cea783070a730ece6f1c6831013","name":"hp-ixgbevf-kmp-default-4.9.3_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-01-09T00:17:05","revision":"0","sha1sum":"cf07545a9209073daf61b4bd7332fb06980a81f7","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecc0badb49"],"type_of_change":"0","version":"4.9.3-1"},{"bytes":"1027253","datemodified":"2021-01-09T00:28:07","file_list":["./etc/depmod.d/hp-ixgbevf.conf","./etc/dracut.conf.d/hp-ixgbevf-oob.conf","./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/hp-ixgbevf","./lib/modules/4.12.14-94.41-default/updates/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/hp-ixgbevf-kmp-default/component.xml"],"md5sum":"e258a73037027999efdc23d663455fa8","name":"hp-ixgbevf-kmp-default-4.9.3_k4.12.14_94.41-1.sles12sp4.x86_64.rpm","release":"2021-01-09T00:17:05","revision":"0","sha1sum":"a66a00efb5ae308d575966266f276bd7f78e45b9","size":"0MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecc0badb49"],"type_of_change":"0","version":"4.9.3-1"}],"id":{"product":"cff92813aa394a808304dff72295152b","version":"7ec0ddeec2514f92a584d20b278cfa37"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 SUSE Linux Enterprise Server 12 x86_64 的 HPE Intel ixgbevf 驅動程式"},{"lang":"en","x_late":"HPE Intel ixgbevf Drivers for SUSE Linux Enterprise Server 12 x86_64"},{"lang":"ko","x_late":"SUSE Linux Enterprise Server 12 x86_64용 HPE Intel ixgbevf 드라이버"},{"lang":"cn","x_late":"适用于 SUSE Linux Enterprise Server 12 x86_64 的 HPE Intel ixgbevf 驱动程序"},{"lang":"ja","x_late":"HPE Intel ixgbevfドライバー for SUSE Linux Enterprise Server 12 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c192d","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c211a","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"},{"dev":"152E","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d3","type":"pci","ven":"8086"},{"dev":"1530","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"1515","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c192d","type":"pci","ven":"8086"},{"dev":"1515","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c211a","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product update Linux kernel documentation and Configure IRQ affinity tools</p>\n","latest_fixes_x_late":"<p>This product corrects an issue which errata kernel loads inbox driver instead of this component after booting into OS</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>This product enhances reliability via adding support for new mailbox communication between PF(Physical Function) and VF(Virtual Function) and remove its potential flaws that may lead to the undefined or faulty behavior</li>\n\t<li>This product enhances compatibility where new mailbox api implementation is alo compatible with old drivers</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"hp-ixgbevf-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbevf-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbevf-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbevf-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5934344","datemodified":"2021-05-18T04:54:09","file_list":["P95_2.90_04_29_2021.signed.flash","SignedImageInstaller64.dll","cp047863.xml","cpqsetup.exe","cpqsysio64.sys"],"md5sum":"dc8586195e97d93310fe6cfb209d1949","name":"cp047863.exe","release":"2021-05-18T04:37:09","revision":"0","sha1sum":"9f694e494a6e78368c4de1ea4848fc1307a5d1ce","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021"}],"id":{"product":"32d8e1ccf0eb436eb79a5663e0e83dbc","version":"27e5d78b388b4c2bbc15e4ba9718f177"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML150 Gen9 (P95) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant ML150 Gen9 (P95)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"edition":"hpc","major":"6","minor":"1","name":"Microsoft Windows HPC Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-05T06:43:46","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"}],"sw_keys":[{"name":"P95","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000JFEPA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRAND5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a46455041","Version":"HPD5"},{"DeviceName":"MB4000JFEPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRAND5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a46455042","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following SAS drive models: MB2000JFEPA and MB4000JFEPB"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のSASドライブモデルのファームウェアを提供します。 MB2000JFEPAおよびMB4000JFEPB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB2000JFEPA and MB4000JFEPB Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD2</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong>&nbsp;&nbsp;&nbsp;&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp; None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>None.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5490903","datemodified":"2021-07-23T07:16:42","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-326de7c0f2-HPD5-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-326de7c0f2-HPD5-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-326de7c0f2-HPD5-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-326de7c0f2-HPD5-8.1/CP048160.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-326de7c0f2-HPD5-8.1/SMKRAND5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-326de7c0f2-HPD5-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-326de7c0f2-HPD5-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-326de7c0f2-HPD5-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-326de7c0f2-HPD5-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048160.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048160.scexe"],"md5sum":"102f6a6022f526c1adb631256bb78935","name":"firmware-hdd-326de7c0f2-HPD5-8.1.x86_64.rpm","release":"2021-07-23T07:03:26","revision":"0","sha1sum":"e6c5e97d87a47228bda45c6906d20cbd7d51b28f","size":"5MB","target_guids":["002340a5-4d00-3242-3030-304a46455041","002340a5-4d00-3442-3030-304a46455042"],"type_of_change":"1","version":"HPD5"}],"id":{"product":"cd64600f655f440ba11117463945fc63","version":"7c8eb566a11a45aab6f4292a14ba4876"},"installation":{"command":"CP040291.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB2000JFEPA and MB4000JFEPB Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB2000JFEPAおよびMB4000JFEPBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB2000JFEPA","target_guid":"002340a5-4d00-3242-3030-304a46455041","type":"sas"},{"id":"MB4000JFEPB","target_guid":"002340a5-4d00-3442-3030-304a46455042","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T19:07:46","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JFEPB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB2000JFEPA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"tw","x_late":"HPE 系統狀況應用程式與命令列公用程式 (hp-health) 彙集了應用程式及工具，可讓您監視風扇、電源供應器、溫度感應器及其他管理事件。此外，亦提供一系列命令列公用程式： ProLiant 開機組態公用程式 (hpbootcfg)、ProLiant 管理命令列介面公用程式 (hpasmcli)、ProLiant 整合式管理記錄 (IML) 公用程式 (hplog) 及 UID (藍色) 燈光公用程式 (hpuid)。"},{"lang":"en","x_late":"The HPE System Health Application and Command Line Utilities (hp-health) is collection of applications and tools which enables monitoring of fans, power supplies, temperature sensors, and other management events.  It also provides collection of command-line utilities: the ProLiant  boot  configuration  utility (hpbootcfg), the ProLiant Management Command Line Interface Utility (hpasmcli), the ProLiant Integrated Management Log (IML) Utility (hplog), and the UID (blue) Light Utility (hpuid)."},{"lang":"ko","x_late":"HPE 시스템 상태 응용 프로그램 및 명령줄 유틸리티(hp-health)는 팬, 전원 공급 장치, 온도 센서 및 기타 관리 이벤트를 모니터링하도록 하는 응용 프로그램 및 도구 모음입니다. 또한 다음과 같은 명령줄 유틸리티 모음을 제공합니다. ProLiant 부팅 구성 유틸리티(hpbootcfg), ProLiant 관리 명령줄 인터페이스 유틸리티(hpasmcli), ProLiant 통합 관리 로그(IML) 유틸리티(hplog) 및 UID(블루) 라이트 유틸리티(hpuid)"},{"lang":"cn","x_late":"HPE System Health Application and Command Line Utilities (hp-health) 是一系列应用程序和工具，能够监控风扇、电源、温度传感器和其他管理事件。它还提供了命令行实用程序集： ProLiant 启动配置实用程序 (hpbootcfg)、ProLiant Management Command Line Interface Utility (hpasmcli)、ProLiant Integrated Management Log (IML) Utility (hplog) 和 UID (blue) Light Utility (hpuid)。"},{"lang":"ja","x_late":"HPEシステムヘルスアプリケーションおよびコマンドラインユーティリティ（hp-health）パッケージは、アプリケーション、およびファンの監視、電源、温度センサー、およびその他管理イベントを行うツールを集めたものです。  また、ProLiantブートコンフィギュレーションユーティリティ（hpbootcfg）、ProLiantマネジメントコマンドラインインターフェイスユーティリティ（hpasmcli）、ProLiantインテグレーテッドマネジメントログ（IML）ユーティリティ（hplog）、およびUID（青）ランプユーティリティ（hpuid）を集めたコマンドラインユーティリティも提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[{"lang":"en","x_late":null}],"files":[{"bytes":"520444","datemodified":"2021-08-25T00:59:37","file_list":["./opt/hp/hp-health","./opt/hp/hp-health/addons","./opt/hp/hp-health/addons/libcpqci64.a","./opt/hp/hp-health/bin","./opt/hp/hp-health/bin/hp-asrd","./opt/hp/hp-health/bin/hpasmlited","./opt/hp/hp-health/bin/hpasmpld","./opt/hp/hp-health/bin/hpasmxld","./opt/hp/hp-health/examples","./opt/hp/hp-health/examples/lite-mgmt","./opt/hp/hp-health/examples/lite-mgmt/COPYING.txt","./opt/hp/hp-health/examples/lite-mgmt/README.txt","./opt/hp/hp-health/examples/lite-mgmt/cma.conf.nosnmp","./opt/hp/hp-health/examples/lite-mgmt/hpsysmon.sh","./opt/hp/hp-health/hp-health.license","./opt/hp/hp-health/hprpm.xpm","./opt/hp/hp-health/sh","./opt/hp/hp-health/sh/hpasmxld_reset.sh","./sbin/hpasmcli","./sbin/hpbootcfg","./sbin/hplog","./sbin/hpuid","./usr/lib/systemd/scripts/hp-asrd.sh","./usr/lib/systemd/scripts/hp-health.sh","./usr/lib/systemd/system/hp-asrd.service","./usr/lib/systemd/system/hp-health.service","./usr/lib64/libcpqci64.so","./usr/lib64/libcpqci64.so.3","./usr/lib64/libcpqci64.so.3.0","./usr/lib64/libhpasmintrfc64.so","./usr/lib64/libhpasmintrfc64.so.3","./usr/lib64/libhpasmintrfc64.so.3.0","./usr/lib64/libhpev64.so","./usr/lib64/libhpev64.so.1","./usr/lib64/libhpev64.so.1.0","./usr/share/man/man4/hp-health.4.gz","./usr/share/man/man4/hpasmcli.4.gz","./usr/share/man/man7/hp_mgmt_install.7.gz","./usr/share/man/man8/hp-asrd.8.gz","./usr/share/man/man8/hpbootcfg.8.gz","./usr/share/man/man8/hplog.8.gz","./usr/share/man/man8/hpuid.8.gz","./usr/share/smartupdate/hp-health/component.xml","./var/log/hp-health","./var/spool/compaq","./var/spool/hp-health"],"md5sum":"b2741cb94fe8bcb99e16087072f98f3a","name":"hp-health-10.93-307.7.rhel7.x86_64.rpm","release":"2021-08-25T00:54:07","revision":"0","sha1sum":"fe655a9ca9bd2a04b115eb82e193988e034cf186","size":"508KB","target_guids":[],"type_of_change":"0","version":"10.9.3"}],"id":{"product":"4a40e009928d473f96b4a66d5f8ed116","version":"bdfd5b3ccd284550ada547692f8a6d3c"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<P>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</P>\n<P>To install the package type: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;rpm -ivh hp-health-&lt;version&gt;.rpm</P>\n<P>To check whether the package is loaded properly type: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;/etc/init.d/hp-health status</P>\n<P>Additional help is available by typing: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;man hp-health</P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;or</P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;man hp_mgmt_install</P>"},{"lang":"ja","x_late":"<P>システム管理者（root）としてログインし、RPMをご使用のハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</P>\n<P>パッケージをインストールするには、次のようにタイプします。 </P>\n<P>      rpm -ivh hp-health-<version>.rpm</P>\n<P>パッケージが正しくロードされているか、以下をタイプして確認します。 </P>\n<P>      /etc/init.d/hp-health status</P>\n<P>以下のコマンドを実行してヘルプを参照してください。 </P>\n<P>      man hp-health</P>\n<P>            または</P>\n<P>      man hp_mgmt_install</P>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Red Hat Enterprise Linux 7 伺服器的 HPE 系統健康狀況應用程式與命令列公用程式"},{"lang":"en","x_late":"HPE System Health Application and Command Line Utilities for Red Hat Enterprise Linux 7 Server"},{"lang":"ko","x_late":"Red Hat Enterprise Linux 7 서버용 HPE 시스템 상태 응용 프로그램 및 명령줄 유틸리티"},{"lang":"cn","x_late":"Red Hat Enterprise Linux 7 Server版HPE System Health应用程序和命令行工具"},{"lang":"ja","x_late":"HPEシステムヘルスアプリケーションおよびコマンドラインユーティリティ for Red Hat Enterprise Linux 7 Server"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"3309","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3307","subdev":"3309","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-10T13:25:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>When a customer queries the HPE Software Delivery Repository (SDR) site and experiences a failure amsd no longer exhibits a&nbsp;segfault.</li>\n\t<li>hp-heath service will no longer crash in a non&nbsp;secure boot environment.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>TBD</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"J06","value":"HP ProLiant MicroServer Gen8"},{"key":"I24","value":"HP ProLiant BL460c G6 Server"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"P88","value":"HP ProLiant ML10 Server"},{"key":"A16","value":"HP ProLiant DL585 G7 Server"},{"key":"I25","value":"HP ProLiant BL680c G7 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 v2 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"A19","value":"HP ProLiant BL465c G7 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"P78","value":"HP ProLiant ML310e Gen8 v2 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"P64","value":"HP ProLiant DL360 G6 Server"},{"key":"P62","value":"HP ProLiant DL380 G6 Server"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"A24","value":"HP ProLiant SL335s G7 Server"},{"key":"P68","value":"HP ProLiant DL360 G7 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"I27","value":"HP ProLiant BL460c G7 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"O41","value":"HP ProLiant MicroServer"},{"key":"A20","value":"HP ProLiant BL685c G7 Server"},{"key":"P67","value":"HP ProLiant DL380 G7 Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"P65","value":"HP ProLiant DL580 G7 Server"}],"sw_keys":[{"name":"hp-health","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The Smart Storage Administrator (SSA) is a web-based application that helps you configure, manage, diagnose, and monitor Smart Array and SmartRAID Controllers and now other storage devices as well, such as host bus adapters (HBAs), Storage controllers, and future devices such as SCSI Express drives, and SAS switch devices. Smart Array Advanced Pack 1.0 and 2.0 features are now part of the baseline features of SSA, with the appropriate firmware."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p>Please make sure the following browser options are enabled:</p>\n\n<ul>\n\t<li>Automatically load images and other data types.</li>\n\t<br />\n\t<li>JAVA script</li>\n\t<br />\n\t<li>Style sheets</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"11772369","datemodified":"2021-08-11T13:15:11","file_list":["./opt/smartstorageadmin/ssa","./opt/smartstorageadmin/ssa/HTML","./opt/smartstorageadmin/ssa/HTML/SSA1","./opt/smartstorageadmin/ssa/HTML/SSA1/css","./opt/smartstorageadmin/ssa/HTML/SSA1/css/fonts","./opt/smartstorageadmin/ssa/HTML/SSA1/css/fonts/hps-euro-bold-woff.woff","./opt/smartstorageadmin/ssa/HTML/SSA1/css/fonts/hps-euro-regular-woff.woff","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/animated-overlay.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_diagonals-thick_18_b81900_40x40.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_diagonals-thick_20_666666_40x40.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_flat_10_000000_40x100.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_glass_100_f6f6f6_1x400.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_glass_100_fdf5ce_1x400.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_glass_65_ffffff_1x400.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_gloss-wave_35_f6a828_500x100.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_highlight-soft_100_eeeeee_1x100.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_highlight-soft_75_ffe45c_1x100.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_222222_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_228ef1_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_ef8c08_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_ffd27a_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_ffffff_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/jquery-ui-1.10.3.custom.min.css","./opt/smartstorageadmin/ssa/HTML/SSA1/css/ssa.min.css","./opt/smartstorageadmin/ssa/HTML/SSA1/favicon.ico","./opt/smartstorageadmin/ssa/HTML/SSA1/images","./opt/smartstorageadmin/ssa/HTML/SSA1/images/OEM","./opt/smartstorageadmin/ssa/HTML/SSA1/images/OEM/logo.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/arraysasssd20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/arraysatassd20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/critical12.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/critical20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/ctrl20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/degraded12.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/degraded20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/embedctrl20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/help20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/infostat12.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/infostat20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/msadevice20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/okay20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdaspare20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdasparerbld20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssddrive20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssddriveerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssddriverbld20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdspare20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdspareerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdudrive20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdudriveerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdaspare20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdasparerbld20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassddrive20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassddriveerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassddriverbld20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdspare20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdspareerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdudrive20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdudriveerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/spacer12.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/ssa.png","./opt/smartstorageadmin/ssa/HTML/SSA1/index.htm","./opt/smartstorageadmin/ssa/HTML/SSA1/js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/globals.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jBox.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery-1.11.2.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery-migrate-1.2.1.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery-ui-1.10.3.custom.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery.tools.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery.ui.selectablessa.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/ssa.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/ssa.htm","./opt/smartstorageadmin/ssa/HTML/SSA1/ssainit.htm","./opt/smartstorageadmin/ssa/HTML/strings","./opt/smartstorageadmin/ssa/HTML/strings/HPE","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_de_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_en_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_es_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_fr_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_it_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_ja_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_pt_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_ru_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_zh_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HStrings.json","./opt/smartstorageadmin/ssa/HTML/strings/MStrings.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_de_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_en_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_es_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_fr_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_it_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_ja_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_pt_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_ru_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_zh_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/StringMaps.json","./opt/smartstorageadmin/ssa/README.TXT","./opt/smartstorageadmin/ssa/bin","./opt/smartstorageadmin/ssa/bin/ssa","./opt/smartstorageadmin/ssa/bin/ssaclient","./opt/smartstorageadmin/ssa/bin/upgrade.txt","./opt/smartstorageadmin/ssa/ssa.license","./usr/man/man8/ssa.8.gz","./usr/sbin/ssa","./usr/share/smartupdate/ssa/component.xml"],"md5sum":"1ee150028a8f41c0bbafeebe4fc3ee5e","name":"ssa-5.20-8.0.x86_64.rpm","release":"2021-08-11T13:11:04","revision":"0","sha1sum":"a2ce4daafa540c07d77a03b2d466125ea2b2c88c","size":"11MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec08c060d2"],"type_of_change":"1","version":"5.20.8.0"}],"id":{"product":"39676e9bd8d74e11b8837e3f6ebabd5c","version":"dd378aacf3c24065a4f2f8dbd0079c57"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<ul>\n\t<li>SSA is distributed using Red Hat Package Manager (RPM) packages.</li>\n\t<li>If there is an older version of SSA installed on the system, please use &quot;rpm -e ssa&quot; to remove it first.</li>\n\t<li>Use &quot;rpm -i &lt;file name&gt;&quot; to install the application.</li>\n\t<li>Please type &quot;man rpm&quot; for other details regarding RPM.</li>\n\t<li>The software resides in /opt/smartstorageadmin/ssa and the executable name is ssa which is located in /usr/sbin.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Smart Storage Administrator (SSA) for Linux 64-bit"},{"lang":"cn","x_late":"64位Linux版Smart Storage Administrator (SSA)"},{"lang":"ja","x_late":"Smart Storage Administrator (SSA) for Linux 64ビット"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-09T05:26:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added&nbsp;support&nbsp;to the HPE&nbsp;SR932i-p and SR416-a&nbsp;Gen10+&nbsp;Controllers.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>.</p>\n\n<p>&nbsp;</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U38","value":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"key":"U38","value":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"key":"","value":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U14","value":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4520 Gen9 Chassis</p>\n"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U27","value":"HPE ProLiant XL2x260w Gen9 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>\n"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"","value":"HPE ProLiant ML150 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"","value":"HPE ProLiant XL770f Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"Carbondale14","value":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"ssa","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains be2net drivers for the HPE Blade Emulex 10/20GbE Server Adapters running under SUSE Linux Enterprise Server 12."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12で動作するHPE Blade Emulex 10/20GbE サーバーアダプター用のbe2net ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"108000","datemodified":"2021-03-08T18:11:45","file_list":["./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/be2net","./lib/modules/4.12.14-94.41-default/updates/be2net/be2net.ko","./usr/share/smartupdate/be2net_bl-kmp-default/component.xml"],"md5sum":"b3b57dda29e23e309de4df9c8806896a","name":"be2net_bl-kmp-default-12.0.1342.0_k4.12.14_94.41-1.sles12sp4.x86_64.rpm","release":"2021-03-08T18:02:04","revision":"0","sha1sum":"8fb0af6de7ac770508fdb1950828ebb73bdc3848","size":"105KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec77a8ea21"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"107845","datemodified":"2021-03-08T18:08:49","file_list":["./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/be2net","./lib/modules/4.12.14-120-default/updates/be2net/be2net.ko","./usr/share/smartupdate/be2net_bl-kmp-default/component.xml"],"md5sum":"66ea757b46b623fa883d5d29e7effd81","name":"be2net_bl-kmp-default-12.0.1342.0_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-03-08T18:02:04","revision":"0","sha1sum":"ff330ccbf17369a2d139194fe48965df3364558c","size":"105KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec77a8ea21"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"b25d6b61a6364a739b769a23e6051253","version":"60f89ebb45d044a299c4062fd1930599"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE Drivers for SUSE Linux Enterprise Server 12"},{"lang":"ja","x_late":"HPE Blade Emulex 10/20GbEドライバー for SUSE Linux Enterprise Server 12"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0728","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c1935","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c1934","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>These drivers have been&nbsp;updated to maintain compatibility with the latest firmware.</p>\n","latest_fixes_x_late":"<p>These drivers have been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product now supports SUSE Linux Enterprise Server 12 SP5.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"be2net_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2net_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2net_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2net_bl-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]}],"documentation":[],"files":[{"bytes":"5551182","datemodified":"2019-08-07T15:57:11","file_list":["./usr/lib/i386-linux-gnu/firmware-system-u26-2.66_2019_07_19-1.1","./usr/lib/i386-linux-gnu/firmware-system-u26-2.66_2019_07_19-1.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-system-u26-2.66_2019_07_19-1.1/.setup","./usr/lib/i386-linux-gnu/firmware-system-u26-2.66_2019_07_19-1.1/CP040772.xml","./usr/lib/i386-linux-gnu/firmware-system-u26-2.66_2019_07_19-1.1/U26_2.66_07_19_2019.signed.flash","./usr/lib/i386-linux-gnu/firmware-system-u26-2.66_2019_07_19-1.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-system-u26-2.66_2019_07_19-1.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP040772.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP040772.scexe"],"md5sum":"ca5b885189b4b13f38fd154010adbd24","name":"firmware-system-u26-2.66_2019_07_19-1.1.i386.rpm","release":"2019-08-07T15:52:03","revision":"0","sha1sum":"8ebf09c2db967ab611ed15cfd14e409ca6689c66","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.66_07-19-2019"}],"id":{"product":"2292648d1a8a4c6db1c16819d8335faf","version":"cee280b6ccca4b71b1af9d8eba25e0ee"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HPE ProLiant Agentless Management Service (<strong>AMS</strong>) and HPE SNMP Agents (<strong>SNMP Agents</strong>) are both running.&nbsp; HPE does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager 8.0.0 or later, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、iLOとの通信ができない場合に失敗します。  これは、HPE ProLiant Agentless Management Service (<strong>AMS</strong>)およびHPE SNMPエージェント(<strong>SNMP Agents</strong>)の両方が実行されているときに発生します。  HPEでは、AMSおよびSNMPエージェントを同時に実行させないことを推奨します。  「iLO device not found」エラーが発生した場合、AMSまたはSNMPエージェントを停止させて、再度フラッシュコンポーネントを実行します。<br />\n<br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上のSmart Update Manager 8.0.0以降を使用して実行できます。</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant EC200a (U26) Server/HPE ProLiant Thin Micro TM200 (U26) Server"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12 for ARM","platform":"suse_linux_enterprise_server_aarch64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-08-24T23:01:21","revision_history":[{"lang":"en","latest_enhancements_x_late":null,"latest_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>Updated the Intel processor microcode to the latest version.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"<p>None</p>\n","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigation for an Intel sighting where the system may experience a machine check after updating to the latest System ROM which contained a fix for an Intel TSX (Transactional Synchronizations Extensions) sightings. The previous microcode was first introduced in the v2.62 System ROM. This issue only impacts systems configured with Intel Xeon&reg; D-1500 processors. This issue is not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U26","value":"HPE ProLiant Easy Connect EC200a Managed Hybrid Server"}],"sw_keys":[{"name":"U26","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware for Converged Network and Network only adapters."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"29522738","datemodified":"2021-09-17T06:11:45","file_list":["./usr/lib/x86_64-linux-gnu/firmware-cna-emulex-2021.10.01-1.5","./usr/lib/x86_64-linux-gnu/firmware-cna-emulex-2021.10.01-1.5/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-cna-emulex-2021.10.01-1.5/.setup","./usr/lib/x86_64-linux-gnu/firmware-cna-emulex-2021.10.01-1.5/CP048539.xml","./usr/lib/x86_64-linux-gnu/firmware-cna-emulex-2021.10.01-1.5/brcmflashStandalone-linux-12.0.1345.0-1.zip","./usr/lib/x86_64-linux-gnu/firmware-cna-emulex-2021.10.01-1.5/firmware","./usr/lib/x86_64-linux-gnu/firmware-cna-emulex-2021.10.01-1.5/firmware/oc14-12.0.1345.0.ufi","./usr/lib/x86_64-linux-gnu/firmware-cna-emulex-2021.10.01-1.5/fwmatrix.txt","./usr/lib/x86_64-linux-gnu/firmware-cna-emulex-2021.10.01-1.5/hpe_fw_matrix.xml","./usr/lib/x86_64-linux-gnu/firmware-cna-emulex-2021.10.01-1.5/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-cna-emulex-2021.10.01-1.5/payload.json","./usr/lib/x86_64-linux-gnu/firmware-cna-emulex-2021.10.01-1.5/readme.txt","./usr/lib/x86_64-linux-gnu/firmware-cna-emulex-2021.10.01-1.5/reference.xml","./usr/lib/x86_64-linux-gnu/firmware-cna-emulex-2021.10.01-1.5/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048539.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048539.scexe"],"md5sum":"722c0e74e99f7fa0f960b94eb1cf10f1","name":"firmware-cna-emulex-2021.10.01-1.5.x86_64.rpm","release":"2021-09-17T05:56:51","revision":"0","sha1sum":"5b3c5df36d997e7f8925c52a38e5559f234c29df","size":"28MB","target_guids":[],"type_of_change":"1","version":"2021.10.01"}],"id":{"product":"2107f9a0dbd947cf9ccebb8283e0e5d0","version":"2f0b203beadc455db9af3533c7310304"},"installation":{"command":"installer","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Firmware installation is a two-step process.&nbsp; Install the firmware installation tool rpm, then execute the installed tool to update the firmware.<br />\n&nbsp;<br />\n&nbsp;1. Install the firmware installation tool:&nbsp; rpm -Uhv &lt;rpm_package_name&gt;.rpm&nbsp; This extracts the firmware installation tool to /usr/lib/x86_64-linux-gnu (64-bit systems)&nbsp;</p>\n\n<p>&nbsp;2. cd to the appropriate location for your system, and update the firmware by executing ./.setup<br />\n&nbsp;<br />\n&nbsp;When the firmware installation completes, you may remove the firmware installation tool from your system using the rpm -e command: rpm -e &lt;rpm_package_name&gt;.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Converged Network Adapters for Linux (x64)"}],"prerequisites":{"required_diskspace":{"size_kb":"20000"},"supported_devices":[{"dev":"0724","subdev":"21D4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"21D4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"8153","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8153","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8144","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"8144","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"220A","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"220A","subven":"103C","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T11:00:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p dir=\"LTR\">We&nbsp;have separate components to update fibre channel and converged network adapters.&nbsp; This is a converged network adapter update component.</p>\n\n<p dir=\"LTR\">This component is only supported on RHEL7u8, RHEL7u9, RHEL8u3, SLES12SP5, SLES15SP2 OS&#39;s.</p>\n\n<p dir=\"LTR\">&nbsp;</p>\n\n<p dir=\"LTR\">This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot BIOS</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 10Gb 2-port 556FLR-T Adapter</td>\n\t\t\t<td>10Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1345.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</td>\n\t\t\t<td>10Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1345.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE CN1200E Dual Port Converged Network Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1345.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE&nbsp;CN1200E-T Dual Port Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1345.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"}],"sw_keys":[{"name":"emulex_cna","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"LO0400KEFJQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-304f-3430-304b45464a51","Version":"HPK4"},{"DeviceName":"LO0800KEFJR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-304f-3830-304b45464a52","Version":"HPK4"},{"DeviceName":"LO1600KEFJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-314f-3630-304b45464a54","Version":"HPK4"},{"DeviceName":"LO2000KEFJU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-324f-3030-304b45464a55","Version":"HPK4"},{"DeviceName":"LT0800KEXVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-3054-3830-304b45585641","Version":"HPK4"},{"DeviceName":"LT1600KEXVB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-3154-3630-304b45585642","Version":"HPK4"},{"DeviceName":"LT2000KEXVC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-3254-3030-304b45585643","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: LO0400KEFJQ, LO0800KEFJR, LO1600KEFJT, LO2000KEFJU, LT0800KEXVA, LT1600KEXVB and LT2000KEXVC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for Linux (x64) - LO0400KEFJQ, LO0800KEFJR, LO1600KEFJT, LO2000KEFJU, LT0800KEXVA, LT1600KEXVB&nbsp;and LT2000KEXVC Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4760195","datemodified":"2021-07-25T12:46:14","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-d64642c780-HPK4-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-d64642c780-HPK4-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-d64642c780-HPK4-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d64642c780-HPK4-6.1/4IFDHPK4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-d64642c780-HPK4-6.1/CP045364.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-d64642c780-HPK4-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d64642c780-HPK4-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-d64642c780-HPK4-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-d64642c780-HPK4-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045364.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045364.scexe"],"md5sum":"9ce597464c7ca0871d8e952112732d96","name":"firmware-hdd-d64642c780-HPK4-6.1.x86_64.rpm","release":"2021-07-25T12:33:18","revision":"0","sha1sum":"300eed7e4c777cdc33cadbbc92ae2cbdeefb99b1","size":"4MB","target_guids":["002340a5-4c00-304f-3430-304b45464a51","002340a5-4c00-304f-3830-304b45464a52","002340a5-4c00-314f-3630-304b45464a54","002340a5-4c00-324f-3030-304b45464a55","002340a5-4c00-3054-3830-304b45585641","002340a5-4c00-3154-3630-304b45585642","002340a5-4c00-3254-3030-304b45585643"],"type_of_change":"1","version":"HPK4"}],"id":{"product":"ae103f89c84644ff9172375f2aa2c907","version":"a3c4d16c14314b6ba853a9f916ec46ec"},"installation":{"command":"CP040114.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - LO0400KEFJQ, LO0800KEFJR, LO1600KEFJT, LO2000KEFJU, LT0800KEXVA, LT1600KEXVB and LT2000KEXVC Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - LO0400KEFJQ、LO0800KEFJR、LO1600KEFJT、LO2000KEFJU、LT0800KEXVA、LT1600KEXVB、およびLT2000KEXVCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"LT0800KEXVA","target_guid":"002340a5-4c00-3054-3830-304b45585641","type":"nvme"},{"id":"LT1600KEXVB","target_guid":"002340a5-4c00-3154-3630-304b45585642","type":"nvme"},{"id":"LT2000KEXVC","target_guid":"002340a5-4c00-3254-3030-304b45585643","type":"nvme"},{"id":"LO2000KEFJU","target_guid":"002340a5-4c00-324f-3030-304b45464a55","type":"nvme"},{"id":"LO0400KEFJQ","target_guid":"002340a5-4c00-304f-3430-304b45464a51","type":"nvme"},{"id":"LO0800KEFJR","target_guid":"002340a5-4c00-304f-3830-304b45464a52","type":"nvme"},{"id":"LO1600KEFJT","target_guid":"002340a5-4c00-314f-3630-304b45464a54","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T11:12:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"LO0400KEFJQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LO1600KEFJT","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LT2000KEXVC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LO0800KEFJR","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LT0800KEXVA","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LT1600KEXVB","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LO2000KEFJU","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"VMware vSphere 6.7 Fibre Channel Driver kit for HPE Emulex Mezzanine Host Bus Adapters(HBAs)"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"734912","datemodified":"2021-08-26T10:41:50","file_list":["/Broadcom-ELX-lpfc_12.8.528.14-1OEM.670.0.0.8169922-offline_bundle-18484921.zip","/cp048585.xml","/Broadcom-ELX-lpfc_12.8.528.14-1OEM.670.0.0.8169922-offline_bundle-18484921.zip/index.xml","/Broadcom-ELX-lpfc_12.8.528.14-1OEM.670.0.0.8169922-offline_bundle-18484921.zip/vendor-index.xml","/Broadcom-ELX-lpfc_12.8.528.14-1OEM.670.0.0.8169922-offline_bundle-18484921.zip/metadata.zip","/Broadcom-ELX-lpfc_12.8.528.14-1OEM.670.0.0.8169922-offline_bundle-18484921.zip/vib20/lpfc/EMU_bootbank_lpfc_12.8.528.14-1OEM.670.0.0.8169922.vib","/Broadcom-ELX-lpfc_12.8.528.14-1OEM.670.0.0.8169922-offline_bundle-18484921.zip/metadata.zip/vendor-index.xml","/Broadcom-ELX-lpfc_12.8.528.14-1OEM.670.0.0.8169922-offline_bundle-18484921.zip/metadata.zip/vmware.xml","/Broadcom-ELX-lpfc_12.8.528.14-1OEM.670.0.0.8169922-offline_bundle-18484921.zip/metadata.zip/vibs/lpfc--6885805289219874139.xml","/Broadcom-ELX-lpfc_12.8.528.14-1OEM.670.0.0.8169922-offline_bundle-18484921.zip/metadata.zip/bulletins/Broadcom-ELX-lpfc_12.8.528.14-1OEM.670.0.0.8169922.xml"],"md5sum":"10e6db1c029acb836e5b9ef79cc33b23","name":"cp048585.zip","release":"2021-08-26T10:41:06","revision":"0","sha1sum":"cc72838a2614a45da7e3f7691ad2dba7ae95bf8d","size":"717KB","target_guids":[],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"lpfc","version":"12.8.528.14-1OEM.670.0.0.8169922"}]}],"id":{"product":"8f815d28e57b4c39acf5f3d214065c30","version":"d1babbc13100452ca5312159c50b7840"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the&nbsp;driver update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware Vsphere Update Manager(VUM) or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on Vsphere Update Manager(VUM) and the esxcli commands</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Emulex Mezzanine Fibre Channel driver component for VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T09:15:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to Driver version 12.8.528.14</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"lpfc:12.8.528.14-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The HPE Agentless Management Service (hp-ams) provides support for HPE Integrated Lights-Out 4 (HPE iLO 4) Embedded Health and Alerting."},{"lang":"ja","x_late":"HPE Agentless Management Service（hp-ams）は、HPE Integrated Lights Out 4（HPE iLO 4）内蔵ヘルスおよびアラートのサポートを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Diagnosing connection issues:</strong></p>\n\n<p>Verify that the HPE iLO 4 is talking to SNMP from a Linux system with net-snmp utilities installed:</p>\n\n<p style=\"margin-left:40px\"><em>snmpwalk -t 60 -v 2c -Ox -c</em> <strong>iLO4_configured_community_string</strong> <strong>iLO4_IP_Address</strong>&nbsp;<em>1.3.6.1.4.1.232.1.1</em></p>\n\n<p>Verify that HPE AMS is operating on the Server:</p>\n\n<p style=\"margin-left:40px\"><em>snmpwalk -t 60 -v 2c -Ox -c</em> <strong>iLO4_configured_community_string</strong> <strong>iLO4_IP_Address</strong>&nbsp;<em>1.3.6.1.4.1.232.5.1</em></p>\n"},{"lang":"ja","x_late":"<p><strong>接続の問題の診断：</strong></p>\n\n<p>HPE iLO 4が、net-snmpユーティリティがインストールされたLinuxシステムから、SNMPに通信していることを確認：</p>\n\n<p style=\"margin-left:40px\"><em>snmpwalk -t 60 -v 2c -Ox -c</em> <strong>iLO4_configured_community_string</strong> <strong>iLO4_IP_Address</strong> <em>1.3.6.1.4.1.232.1.1</em></p>\n\n<p>サーバー上でHPE AMSが動作していることを確認：</p>\n\n<p style=\"margin-left:40px\"><em>snmpwalk -t 60 -v 2c -Ox -c</em> <strong>iLO4_configured_community_string</strong> <strong>iLO4_IP_Address</strong> <em>1.3.6.1.4.1.232.5.1</em></p>\n"}],"files":[{"bytes":"792845","datemodified":"2021-10-06T05:24:41","file_list":["./etc/sysconfig/hp-ams","./opt/hp/hp-ams","./opt/hp/hp-ams/hp-ams.license","./sbin/amsHelper","./usr/lib/.build-id","./usr/lib/.build-id/b4","./usr/lib/.build-id/b4/2ec0adababf02d091b573511f60dc30a432406","./usr/lib/systemd/system/hp-ams.service","./usr/share/man/man8/amsHelper.8.gz","./usr/share/smartupdate/hp-ams/component.xml"],"md5sum":"37203ad26efd86608ee1824192f6de39","name":"hp-ams-2.10.4-885.5.rhel8.x86_64.rpm","release":"2021-10-06T05:14:41","revision":"0","sha1sum":"8e5886caec07b2527699b3309a46a2453dfabe59","size":"774KB","target_guids":[],"type_of_change":"0","version":"2.10.4"}],"id":{"product":"ff838e600d484f85bc0967ebce9789c9","version":"752303a173634736bfc909800ab91e1a"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"","SubRequirements":[]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>To install the package type:</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;rpm -ivh hp-ams-&lt;version&gt;.rpm</p>\n\n<p>To check whether the package is loaded properly type:</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;systemctl status hp-ams</p>\n\n<p>Additional help is available by typing:</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;man amshelper</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE ProLiant Agentless Management Service for Red Hat Enterprise Linux 8 Server"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"id":"5219994","target_guid":"","type":"other"},{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3300","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3302","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-21T13:29:41","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>Addressed&nbsp;a small amount of memory leak as documented in the Customer Advisory, <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00053824en_us\" style=\"color:#0563c1; text-decoration:underline\">a00053824en_us</a></li>\n\t<li>&nbsp;NVMe drive information is now available in the CPQSE.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>Drive&nbsp;status all shows failed on SL4540 Gen8 H220 [LSI] ILO4 due to&nbsp; incorrect SCSI command tags.</li>\n\t<li>Addressed issue where hp-ams may fail to start when&nbsp;U.3 NVMe devices are installed in the system</li>\n\t<li>The HPE Synergy 6810C 25/50Gb Ethernet Adapter not displaying information in hp-ams is now resolved</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"J06","value":"HP ProLiant MicroServer Gen8"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 v2 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P78","value":"HP ProLiant ML310e Gen8 v2 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P88","value":"HP ProLiant ML10 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"}],"sw_keys":[{"name":"hp-ams","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11400032","languages":[{"lang":"tw","x_late":"應用程式 - 系統管理"},{"lang":"en","x_late":"Application - System Management"},{"lang":"ko","x_late":"응용 프로그램 - 시스템 관리"},{"lang":"ja","x_late":"アプリケーション - システム マネジメント"},{"lang":"cn","x_late":"应用程序 - 系统管理"}]}],"description":[{"lang":"en","x_late":"Integrated Smart Update Tools (iSUT) is an application which enables firmware and software deployment via the iLO management network using the server’s local administrator credentials. iSUT can run as a service when working with HPE OneView managed servers or iLO Amplifier Pack or in an On Demand mode. iSUT requires a Service Pack for ProLiant-based ISO containing Smart Update Manager version 8.0.0 or later and an iLO Advanced Pack license for deployment."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]}],"documentation":[],"files":[{"bytes":"7758422","datemodified":"2021-09-06T07:28:41","file_list":["./opt/hp/hpsut/README.txt","./opt/sut/README.txt","./opt/sut/bin/gatherlogs.sh","./opt/sut/bin/hpsut","./opt/sut/bin/sut","./opt/sut/bin/x64/sum_drop_table_x64","./opt/sut/config/sut_cfg_default.dat","./opt/sut/doc/OnDemandHelp.txt","./opt/sut/schemas/SUT.json","./opt/sut/schemas/SUTProvider.json","./opt/sut/schemas/SUTProvider_Gen10.json","./opt/sut/schemas/SUTRegistryEN_Legacy_zipped.json.gz","./opt/sut/schemas/SUTRegistryEN_Redfish.json","./opt/sut/schemas/SUTRegistryEN_Redfish_zipped.json.gz","./opt/sut/schemas/SUTRegistryJP_Legacy_zipped.json.gz","./opt/sut/schemas/SUTRegistryJP_Redfish_zipped.json.gz","./opt/sut/schemas/SUTSchema_Legacy_zipped.json.gz","./opt/sut/schemas/SUTSchema_Redfish_zipped.json.gz","./opt/sut/schemas/SUTSettings.json","./opt/sut/schemas/SUTSettingsSchema_Legacy_zipped.json.gz","./opt/sut/schemas/SUTSettingsSchema_Redfish_zipped.json.gz","./opt/sut/schemas/SUTSettings_Gen10.json","./opt/sut/schemas/SUTSystemInventorySchema_Legacy_zipped.json.gz","./opt/sut/schemas/SUTSystemInventorySchema_Redfish_zipped.json.gz","./opt/sut/schemas/SUTTasksettings.json","./opt/sut/schemas/SUTTasksettings_Legacy_zipped.json.gz","./opt/sut/schemas/SUTTasksettings_Redfish_zipped.json.gz","./opt/sut/schemas/SUT_Gen10.json","./opt/sut/scripts/sut.service","./opt/sut/scripts/sutd","./usr/share/man/man8/sut.8.gz","./usr/share/smartupdate/sut/component.xml"],"md5sum":"1011e2c5a7b9da72fc60506b1f33a725","name":"sut-2.9.0-53.linux.x86_64.rpm","release":"2021-09-06T12:19:05","revision":"0","sha1sum":"ceb9144e305af043ed77083704ec1220ccb0915c","size":"7MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ece09b5689"],"type_of_change":"1","version":"2.9.0.0"}],"id":{"product":"b3a8e7e2c4ea466a9b404955f474449e","version":"1313ed49b04f414f901f3e94a3a4b05c"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the rpm package to a directory on your hard drive and change to that directory. Install by typing rpm -Uvh hpsut-XXX.x86_64.rpm.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Integrated Smart Update Tools for Linux x64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3307103c3381","type":"pci","ven":"103C"},{"dev":"3307","subdev":"1979","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3307103c1979","type":"pci","ven":"103C"},{"dev":"3308","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3308103c3381","type":"pci","ven":"103C"},{"dev":"3300","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3300103c3381","type":"pci","ven":"103C"},{"dev":"3301","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3301103c3381","type":"pci","ven":"103C"},{"dev":"3302","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3302103c3381","type":"pci","ven":"103C"},{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3306103c3381","type":"pci","ven":"103C"},{"dev":"3306","subdev":"1979","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3306103c1979","type":"pci","ven":"103C"},{"dev":"3307","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3307159000e4","type":"pci","ven":"103C"},{"dev":"3307","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3306159000e4","type":"pci","ven":"103C"},{"dev":"3306","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-08T06:42:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>See the&nbsp;<a href=\"http://www.hpe.com/info/sut-docs\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>\n","latest_fixes_x_late":"<p>See the&nbsp;<a href=\"http://www.hpe.com/info/sut-docs\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>\n"},{"curr_enhancements_x_late":"<p>See the&nbsp;<a href=\"http://www.hpe.com/info/sut-docs\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>\n","curr_fixes_x_late":"<p>See the&nbsp;<a href=\"http://www.hpe.com/info/sut-docs\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"","value":"HP Smart Update Tools (HP SUT)"},{"key":"U26","value":"HPE ProLiant Easy Connect EC200a Managed Hybrid Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U24","value":"HPE ProLiant XL2x260w Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"sut","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Intel igbn Adapters running under VMware vSphere 7.0."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;1.5.2.0.</p>\n"}],"files":[{"bytes":"121871","datemodified":"2021-08-11T09:34:21","file_list":["/cp047111.xml","/Intel-igbn_1.5.2.0-1OEM.700.1.0.15843807_17292660.zip","/Intel-igbn_1.5.2.0-1OEM.700.1.0.15843807_17292660.zip/index.xml","/Intel-igbn_1.5.2.0-1OEM.700.1.0.15843807_17292660.zip/vendor-index.xml","/Intel-igbn_1.5.2.0-1OEM.700.1.0.15843807_17292660.zip/metadata.zip","/Intel-igbn_1.5.2.0-1OEM.700.1.0.15843807_17292660.zip/vib20/igbn/INT_bootbank_igbn_1.5.2.0-1OEM.700.1.0.15843807.vib","/Intel-igbn_1.5.2.0-1OEM.700.1.0.15843807_17292660.zip/metadata.zip/vendor-index.xml","/Intel-igbn_1.5.2.0-1OEM.700.1.0.15843807_17292660.zip/metadata.zip/vmware.xml","/Intel-igbn_1.5.2.0-1OEM.700.1.0.15843807_17292660.zip/metadata.zip/vibs/igbn-2757282774975846762.xml","/Intel-igbn_1.5.2.0-1OEM.700.1.0.15843807_17292660.zip/metadata.zip/bulletins/Intel-igbn_1.5.2.0-1OEM.700.1.0.15843807.xml"],"md5sum":"10fc3f2640bdcc212ec7261dcbf06252","name":"cp047111.zip","release":"2021-08-11T09:31:04","revision":"0","sha1sum":"a79b56c2863c921d34d8397ab87ac1d64bc94827","size":"119KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55","20a6e8e4-bf33-4c71-a6bf-d9ecd203bbc1"],"type_of_change":"0","version":"2021.09.04","vib_list":[{"name":"igbn","version":"1.5.2.0-1OEM.700.1.0.15843807"}]}],"id":{"product":"d6816ab14fc34e169d27b5a4d2e7e7a1","version":"bd5f680cb0284f84938c9958546b8381"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバーにUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel igbn Driver for VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"1523","subdev":"1989","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1523103c1989","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00FF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1521159000ff","type":"pci","ven":"8086"},{"dev":"1521","subdev":"337F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c337f","type":"pci","ven":"8086"},{"dev":"1521","subdev":"339E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c339e","type":"pci","ven":"8086"},{"dev":"1521","subdev":"17D1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c17d1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"3380","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-1521103c3380","type":"pci","ven":"8086"},{"dev":"1521","subdev":"8157","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c8157","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00A3","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a3","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue which handling duplex value passed of ESXi command.</p>\n"},{"curr_enhancements_x_late":"<p>This product supports the following new server:</p>\n\n<ul>\n\t<li>HPE ProLiant DL20 Gen10 Plus Server</li>\n\t<li>HPE ProLiant ML30 Gen10 Plus Server&nbsp;</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"igbn:1.5.2.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"Intel-igbn:1.5.2.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver.component:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox adapter cards."},{"lang":"ja","x_late":"このRPMには、サポートされているHPE Mellanoxアダプターカード用のHPEによるテストと承認済みのLinuxベースMellanox RoCE (RDMA over Converged Ethernet)ドライバーが含まれます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"2257600","datemodified":"2021-05-17T20:14:18","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/connectx.conf","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d/mlx4.driver","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/security/limits.d/30-libvma-limits.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/82-net-setup-link.rules","./etc/udev/rules.d/90-ib.rules","./sbin/connectx_port_config","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/ibdev2netdev","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_get_vfs.pl","./usr/bin/mlnx_perf","./usr/bin/mlnx_qcn","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/lib/python2.7/site-packages/dcbnetlink.py","./usr/lib/python2.7/site-packages/genetlink.py","./usr/lib/python2.7/site-packages/netlink.py","./usr/lib/python2.7/site-packages/ofed_le_utils-1.0.3-py2.7.egg-info","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/vma.service","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.0","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.0.0","./usr/lib64/libmlx4-rdmav2.so","./usr/lib64/libmlx5-rdmav2.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.0.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.0.0","./usr/lib64/libvma-debug.so","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.0.2","./usr/lib64/mlnx_ofed/valgrind/libibverbs.so.1","./usr/lib64/mlnx_ofed/valgrind/libibverbs.so.1.0.0","./usr/lib64/mlnx_ofed/valgrind/libmlx4-rdmav2.so","./usr/lib64/mlnx_ofed/valgrind/libmlx4.so","./usr/lib64/mlnx_ofed/valgrind/libmlx5-rdmav2.so","./usr/lib64/mlnx_ofed/valgrind/libmlx5.so.1","./usr/lib64/mlnx_ofed/valgrind/libmlx5.so.1.0.0","./usr/lib64/mlnx_ofed/valgrind/librdmacm.so.1","./usr/lib64/mlnx_ofed/valgrind/librdmacm.so.1.0.0","./usr/lib64/mlnx_ofed/valgrind/rsocket/librspreload.so.1","./usr/lib64/mlnx_ofed/valgrind/rsocket/librspreload.so.1.0.0","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vma","./usr/sbin/vmad","./usr/share/doc/ib2ib","./usr/share/doc/ib2ib/README","./usr/share/doc/libibumad-43.1.1.MLNX20200211.078947f","./usr/share/doc/libibumad-43.1.1.MLNX20200211.078947f/AUTHORS","./usr/share/doc/libibumad-43.1.1.MLNX20200211.078947f/COPYING","./usr/share/doc/libibumad-43.1.1.MLNX20200211.078947f/ChangeLog","./usr/share/doc/libibverbs-41mlnx1","./usr/share/doc/libibverbs-41mlnx1/AUTHORS","./usr/share/doc/libibverbs-41mlnx1/COPYING","./usr/share/doc/libibverbs-41mlnx1/ChangeLog","./usr/share/doc/libibverbs-41mlnx1/README","./usr/share/doc/libmlx4-41mlnx1","./usr/share/doc/libmlx4-41mlnx1/AUTHORS","./usr/share/doc/libmlx4-41mlnx1/COPYING","./usr/share/doc/libmlx4-41mlnx1/README","./usr/share/doc/libmlx5-41mlnx1","./usr/share/doc/libmlx5-41mlnx1/AUTHORS","./usr/share/doc/libmlx5-41mlnx1/COPYING","./usr/share/doc/libmlx5-41mlnx1/README","./usr/share/doc/librdmacm-41mlnx1","./usr/share/doc/librdmacm-41mlnx1/AUTHORS","./usr/share/doc/librdmacm-41mlnx1/COPYING","./usr/share/doc/librdmacm-41mlnx1/README","./usr/share/doc/libvma-9.0.2/README.txt","./usr/share/doc/libvma-9.0.2/VMA_VERSION","./usr/share/doc/libvma-9.0.2/journal.txt","./usr/share/man/man3/umad_addr_dump.3.gz","./usr/share/man/man3/umad_alloc.3.gz","./usr/share/man/man3/umad_attribute_str.3.gz","./usr/share/man/man3/umad_class_str.3.gz","./usr/share/man/man3/umad_close_port.3.gz","./usr/share/man/man3/umad_debug.3.gz","./usr/share/man/man3/umad_done.3.gz","./usr/share/man/man3/umad_dump.3.gz","./usr/share/man/man3/umad_free.3.gz","./usr/share/man/man3/umad_free_ca_namelist.3.gz","./usr/share/man/man3/umad_get_ca.3.gz","./usr/share/man/man3/umad_get_ca_namelist.3.gz","./usr/share/man/man3/umad_get_ca_portguids.3.gz","./usr/share/man/man3/umad_get_cas_names.3.gz","./usr/share/man/man3/umad_get_fd.3.gz","./usr/share/man/man3/umad_get_issm_path.3.gz","./usr/share/man/man3/umad_get_mad.3.gz","./usr/share/man/man3/umad_get_mad_addr.3.gz","./usr/share/man/man3/umad_get_pkey.3.gz","./usr/share/man/man3/umad_get_port.3.gz","./usr/share/man/man3/umad_init.3.gz","./usr/share/man/man3/umad_mad_status_str.3.gz","./usr/share/man/man3/umad_method_str.3.gz","./usr/share/man/man3/umad_open_port.3.gz","./usr/share/man/man3/umad_poll.3.gz","./usr/share/man/man3/umad_recv.3.gz","./usr/share/man/man3/umad_register.3.gz","./usr/share/man/man3/umad_register2.3.gz","./usr/share/man/man3/umad_register_oui.3.gz","./usr/share/man/man3/umad_release_ca.3.gz","./usr/share/man/man3/umad_release_port.3.gz","./usr/share/man/man3/umad_send.3.gz","./usr/share/man/man3/umad_set_addr.3.gz","./usr/share/man/man3/umad_set_addr_net.3.gz","./usr/share/man/man3/umad_set_grh.3.gz","./usr/share/man/man3/umad_set_grh_net.3.gz","./usr/share/man/man3/umad_set_pkey.3.gz","./usr/share/man/man3/umad_size.3.gz","./usr/share/man/man3/umad_status.3.gz","./usr/share/man/man3/umad_unregister.3.gz","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml","./usr/lib/python2.7/site-packages/dcbnetlink.pyc","./usr/lib/python2.7/site-packages/dcbnetlink.pyo","./usr/lib/python2.7/site-packages/genetlink.pyc","./usr/lib/python2.7/site-packages/genetlink.pyo","./usr/lib/python2.7/site-packages/netlink.pyc","./usr/lib/python2.7/site-packages/netlink.pyo"],"md5sum":"8ef151ac995e81829571e5a877bc7738","name":"mlnx-ofa_kernel-4.9-OFED.4.9.3.1.6.1.rhel7u9.x86_64.rpm","release":"2021-05-17T19:02:05","revision":"0","sha1sum":"9ca8e23f3d0298f1e87a906e0835bfb024d02f78","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81"],"type_of_change":"1","version":"4.9"},{"bytes":"1694092","datemodified":"2021-05-17T20:20:08","file_list":["./etc/depmod.d/zz01-mlnx-ofa_kernel-bnxt_re.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-efa.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-hfi1.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-i40iw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ipath.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ipoib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_iser.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_isert.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_mthca.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_qib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srp.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srpt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_umad.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_uverbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cxgb3.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cxgb4.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_nes.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_en.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_fpga_tools.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx_compat.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxfw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvme-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvmet-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ocrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-opa_vnic.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-qedr.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_rxe.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdmavt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rpcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-svcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-usnic_verbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-vmw_pvrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-xprtrdma.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/compat","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/compat/mlx_compat.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_cm.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_core.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_ucm.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_umad.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/iw_cm.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_cm.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb3","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb3/iw_cxgb3.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa/efa.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/i40iw","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ipath","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ipath/ib_ipath.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mthca","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mthca/ib_mthca.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/nes","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/nes/iw_nes.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ocrdma","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ocrdma/ocrdma.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qib","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qib/ib_qib.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx4","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx4/mlx4_core.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx4/mlx4_en.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/fpga","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/fpga/mlx5_fpga_tools.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host/nvme-rdma.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/net","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/kmod-mlnx-ofa_kernel/component.xml"],"md5sum":"5b063772b2e30dc5841b5c896d31819f","name":"kmod-mlnx-ofa_kernel-4.9-OFED.4.9.3.1.6.1.rhel7u9.x86_64.rpm","release":"2021-05-17T19:02:05","revision":"0","sha1sum":"dbf8afd1a3fbb6e1457058ce0df06e15c94877f5","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81"],"type_of_change":"1","version":"4.9"}],"id":{"product":"408f4a25d4b44e79916ac17904fc2648","version":"ce152e8d95da491aa19cdb4d096b6ea9"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)","OSVersion":{"name":"Linux","value":"6.9"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)","OSVersion":{"name":"Linux","value":"6.10"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)","OSVersion":{"name":"Linux","value":"7.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)","OSVersion":{"name":"Linux","value":"7.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-4.9&quot;&nbsp;RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.&nbsp;<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using kernel version 3.10.0-1160.el7.x86_64&nbsp;or any future errata:<br />\n<br />\n<strong># rpm -Uvh&nbsp;kmod-mlnx-ofa_kernel-4.9-OFED.4.9.3.1.6.1.rhel7u9.x86_64.rpm&nbsp;mlnx-ofa_kernel-4.9-OFED.4.9.3.1.6.1.rhel7u9.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for Red Hat Enterprise Linux 7 Update 9 (x86_64)"},{"lang":"ja","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet)ドライバー for Red Hat Enterprise Linux 7 Update 9 (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-17T16:50:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>The following changes and new features are added in version 4.9:</strong></p>\n\n<ul>\n\t<li><strong>For ConnectX-5 Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Option to dump configuration space via the devlink tool in order to improve debug capabilities.</li>\n\t<li>The conventional TX descriptor (WQE or Work Queue Element) describes a single packet for transmission. Added driver support for the HW feature of multi-packet TX WQEs in XDP transmit flows. With this, the HW becomes capable of working with a new and improved WQE layout that describes several packets. In effect, this feature saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>GENEVE encapsulation/decapsulation rules offload.</li>\n\t<li>Driver support for the hardware feature of multi-packet Tx to work with a new and improved WQE layout that describes several packets instead of a single packet for XDP transmission flows. This saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>Updating CT (Connection Tracking) rules using the software steering mechanism.</li>\n\t<li>Updating remote mirroring rules using the software steering mechanism.<br />\n\t&nbsp;</li>\n\t<li><strong>For ConnectX-4&nbsp;Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Exposed rx_prio[p]_discards discard counters per priority that count the number of received packets dropped due to lack of buffers on the physical port.</li>\n\t<li>Reporting TSO and CSUM offload capabilities for MPLS tagged traffic and, allowed the kernel stack to use these offloads.</li>\n\t<li>mlx5e Max Combined Channels Increased the driver&rsquo;s maximal combined channels value from 64 to 128 (however, note that OOB value will not cross 64). 128 is the upper bound. Lower maximal value can be seen on the host, depending on the number of cores and MSIX&#39;s configured by the firmware.</li>\n\t<li>Added the following RoCE accelerator counters:\n\t<ul>\n\t\t<li>roce_adp_retrans - counts the number of adaptive retransmissions for RoCE traffic.</li>\n\t\t<li>roce_adp_retrans_to - counts the number of times RoCE traffic reached timeout due to adaptive retransmission.</li>\n\t\t<li>roce_slow_restart - counts the number of times RoCE slow restart was used.</li>\n\t\t<li>roce_slow_restart_cnps - counts the number of times RoCE slow restart generated CNP packets roce_slow_restart_trans - counts the number of times RoCE slow restart changed state to slow restart.</li>\n\t</ul>\n\t</li>\n\t<li>User to register memory regions with a relaxed ordering access flag through experimental verbs. This can enhance performance, depending on architecture and scenario.<br />\n\t&nbsp;</li>\n\t<li><strong>For&nbsp;All HCA&#39;s</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Output ibdev2netdev tool output was changed such that the bonding device now points at the bond instead of the slave interface.</li>\n\t<li>Monitoring and recovering from errors that occur on the RX queue, such as cookie errors and timeout.</li>\n\t<li>Improved GSO (Generic Segmentation Offload) workload performance by decreasing doorbells usage to the minimum required.</li>\n\t<li>TX CQE (Completion Queue Element) compression. Saves on outgoing PCIe bandwidth by compressing CQEs together. Disabled by default. Configurable via private flags of ethtool.</li>\n\t<li>Firmware Versions Query via Devlink :Added the option to query for running and stored firmware versions using the devlink tool.</li>\n\t<li>Firmware Flash Update via Devlink :Added the option to update the firmware image in the flash using the devlink tool. Usage: devlink dev flash file .mfa2 For further information on how to perform this update, see &quot;Updating Firmware Using ethtool/devlink and .mfa2 File&quot; section in MFT User Manual.</li>\n\t<li>WQE (Work Queue Element) dump, triggered by an error on Rx/Tx reporters. In addition, some dumps (not triggered by an error) can be retrieved by the user via devlink health reporters.</li>\n\t<li>GENEVE tunneled hardware offloads of TSO, CSUM and RSS.</li>\n\t<li>TCP segmentation and checksum offload support for MPLS-tagged traffic.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 4.9:</strong></p>\n\n<ul>\n\t<li>An issue where injecting EEH (Extended Error Handlng) may cause extra Kernel prints, such as: &ldquo;EEH: Might be infinite loop in mlx5_core driver&rdquo; was fixed.</li>\n\t<li>RPM-based OSs with non-default kernels, using repositories after re-creating the installer (using --add-kernel-support) were&nbsp;resulting&nbsp;in improper installation of the drivers.</li>\n\t<li>A typo in perftest package where help messages wrongly displayed the conversion result between Gb/s and MB/s (20^2 instead of 2^20).</li>\n\t<li>When one of the LAG slaves went down, LAG deactivation failed, ultimately causing bandwidth degradation.</li>\n\t<li>The mlx5 driver maintains a subdirectory for every open eth port in /sys/kernel/debug/. For the default network namespace, the sub-directory name is the name of the interface, like &quot;eth8&quot;. The new convention for the network interfaces moved to the non-default network namespaces is the interfaces name followed by &quot;@&quot; and the port&#39;s PCI ID. For example: &quot;eth8@0000:af:00.3&quot;.</li>\n\t<li>&quot;openibd&quot; script load used to fail when esp6_offload module did not load successfully.</li>\n\t<li>Added dependency of package mpi-selectors on perl-Getopt-Long system package. On minimal installs of RPM-based OSs, installing mpi-selectros will also install the required system package perl-Getopt-Long.</li>\n\t<li>During certain rare scenarios, due to Rx page not being replenished, the same page fragment mistakenly became assigned to two different Rx descriptors.</li>\n\t<li>Driver load issue existed with Errata-kernel on SLES15 SP1.</li>\n\t<li>An issue in the Hairpin feature which prevented adding hairpin flows using TC tool was fixed.</li>\n\t<li>WQ (Work Queue)&nbsp;queue flushing was not handled properly in the event of EEH.</li>\n\t<li>A rare kernel crash scenario when exiting an application that uses RMPP mads intensively.</li>\n\t<li>A possible kernel crash scenario when AER/slot reset in done in parallel to user space commands execution.</li>\n\t<li>Added missing ECN (Explicit Congestion Notification) configuration under sysfs for PFs in SwitchDev mode.</li>\n\t<li>When firmware response time to commands became very long, some commands failed upon timeout. The driver may have then triggered a timeout completion on the wrong entry, leading to a NULL pointer call trace.</li>\n\t<li>Added driver support for kernels with the old XDP_REDIRECT infrastructure that uses the following NetDev operations: .ndo_xdp_flush and .ndo_xdp_xmit.</li>\n\t<li>Usage of --excludedocs Open MPI RPM option resulted in the removal of non-documentation related files.</li>\n\t<li>Disabled automated loading of some modules through udev triggers to preserve the startup process of previous MLNX_OFED versions.</li>\n\t<li>Reference count (refcount) for RDMA connection ID (cm_id) was not incremented in rdma_resolve_addr() function, resulting in a cm_id use-after-free access. A fix was applied to increment the cm_id refcount</li>\n\t<li>A race condition which caused kernel panic when moving two ports to SwitchDev mode at the same time.</li>\n\t<li>Allowed accessing sysfs hardware counters in SwitchDev mode</li>\n\t<li>Function smp_processor_id() is called in the RX page recycle flow to determine the core to run on. This is intended to run in NAPI context. However, due to a bug in backporting, the RX page recycle was mistakenly called also in the RQ close flow when not needed.</li>\n\t<li>Port link state was automatically changed (without admin state involvement) to &quot;UP&quot; after reboot.</li>\n\t<li>ConnectX-3 adapter cards froze when running over SLES 11 OS.</li>\n\t<li>RDMA CM (Remote Direct Memory Access Communation Manager) connection failed when port space was small.</li>\n\t<li>Traffic mirroring with OVS (Open VSwitch)offload and non-offload over VxLAN interface is now supported. Note: For kernel 4.9, make sure to use a dedicated OVS version.</li>\n\t<li>When working with VF LAG while the bond device is in active-active mode, running fwreset would result in unequal traffic on both PFs, and PFs would not reach line rate.</li>\n\t<li>When bond was created over VF (Virtuaal Function)&nbsp;netdevices in SwitchDev mode, the VF netdevice would be treated as representor netdevice. This caused the mlx5_core driver to crash in case it received netdevice events related to bond device.</li>\n\t<li>An issue where following a bad affinity occurrence in VF LAG mode, traffic was sent after the port went up/down in the switch.</li>\n\t<li>Added support for VLAN (Virtual Local Area Network)&nbsp;header rewrite on CentOS 7.2 OS.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>The following changes and new features are added in version 4.9:</strong></p>\n\n<ul>\n\t<li><strong>For ConnectX-5 Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Option to dump configuration space via the devlink tool in order to improve debug capabilities.</li>\n\t<li>The conventional TX descriptor (WQE or Work Queue Element) describes a single packet for transmission. Added driver support for the HW feature of multi-packet TX WQEs in XDP transmit flows. With this, the HW becomes capable of working with a new and improved WQE layout that describes several packets. In effect, this feature saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>GENEVE encapsulation/decapsulation rules offload.</li>\n\t<li>Driver support for the hardware feature of multi-packet Tx to work with a new and improved WQE layout that describes several packets instead of a single packet for XDP transmission flows. This saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>Updating CT (Connection Tracking) rules using the software steering mechanism.</li>\n\t<li>Updating remote mirroring rules using the software steering mechanism.<br />\n\t&nbsp;</li>\n\t<li><strong>For ConnectX-4&nbsp;Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Exposed rx_prio[p]_discards discard counters per priority that count the number of received packets dropped due to lack of buffers on the physical port.</li>\n\t<li>Reporting TSO and CSUM offload capabilities for MPLS tagged traffic and, allowed the kernel stack to use these offloads.</li>\n\t<li>mlx5e Max Combined Channels Increased the driver&rsquo;s maximal combined channels value from 64 to 128 (however, note that OOB value will not cross 64). 128 is the upper bound. Lower maximal value can be seen on the host, depending on the number of cores and MSIX&#39;s configured by the firmware.</li>\n\t<li>Added the following RoCE accelerator counters:\n\t<ul>\n\t\t<li>roce_adp_retrans - counts the number of adaptive retransmissions for RoCE traffic.</li>\n\t\t<li>roce_adp_retrans_to - counts the number of times RoCE traffic reached timeout due to adaptive retransmission.</li>\n\t\t<li>roce_slow_restart - counts the number of times RoCE slow restart was used.</li>\n\t\t<li>roce_slow_restart_cnps - counts the number of times RoCE slow restart generated CNP packets roce_slow_restart_trans - counts the number of times RoCE slow restart changed state to slow restart.</li>\n\t</ul>\n\t</li>\n\t<li>User to register memory regions with a relaxed ordering access flag through experimental verbs. This can enhance performance, depending on architecture and scenario.<br />\n\t&nbsp;</li>\n\t<li><strong>For&nbsp;All HCA&#39;s</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Output ibdev2netdev tool output was changed such that the bonding device now points at the bond instead of the slave interface.</li>\n\t<li>Monitoring and recovering from errors that occur on the RX queue, such as cookie errors and timeout.</li>\n\t<li>Improved GSO (Generic Segmentation Offload) workload performance by decreasing doorbells usage to the minimum required.</li>\n\t<li>TX CQE (Completion Queue Element) compression. Saves on outgoing PCIe bandwidth by compressing CQEs together. Disabled by default. Configurable via private flags of ethtool.</li>\n\t<li>Firmware Versions Query via Devlink :Added the option to query for running and stored firmware versions using the devlink tool.</li>\n\t<li>Firmware Flash Update via Devlink :Added the option to update the firmware image in the flash using the devlink tool. Usage: devlink dev flash file .mfa2 For further information on how to perform this update, see &quot;Updating Firmware Using ethtool/devlink and .mfa2 File&quot; section in MFT User Manual.</li>\n\t<li>WQE (Work Queue Element) dump, triggered by an error on Rx/Tx reporters. In addition, some dumps (not triggered by an error) can be retrieved by the user via devlink health reporters.</li>\n\t<li>GENEVE tunneled hardware offloads of TSO, CSUM and RSS.</li>\n\t<li>TCP segmentation and checksum offload support for MPLS-tagged traffic.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 4.9:</strong></p>\n\n<ul>\n\t<li>An issue where injecting EEH (Extended Error Handlng) may cause extra Kernel prints, such as: &ldquo;EEH: Might be infinite loop in mlx5_core driver&rdquo; was fixed.</li>\n\t<li>RPM-based OSs with non-default kernels, using repositories after re-creating the installer (using --add-kernel-support) were&nbsp;resulting&nbsp;in improper installation of the drivers.</li>\n\t<li>A typo in perftest package where help messages wrongly displayed the conversion result between Gb/s and MB/s (20^2 instead of 2^20).</li>\n\t<li>When one of the LAG slaves went down, LAG deactivation failed, ultimately causing bandwidth degradation.</li>\n\t<li>The mlx5 driver maintains a subdirectory for every open eth port in /sys/kernel/debug/. For the default network namespace, the sub-directory name is the name of the interface, like &quot;eth8&quot;. The new convention for the network interfaces moved to the non-default network namespaces is the interfaces name followed by &quot;@&quot; and the port&#39;s PCI ID. For example: &quot;eth8@0000:af:00.3&quot;.</li>\n\t<li>&quot;openibd&quot; script load used to fail when esp6_offload module did not load successfully.</li>\n\t<li>Added dependency of package mpi-selectors on perl-Getopt-Long system package. On minimal installs of RPM-based OSs, installing mpi-selectros will also install the required system package perl-Getopt-Long.</li>\n\t<li>During certain rare scenarios, due to Rx page not being replenished, the same page fragment mistakenly became assigned to two different Rx descriptors.</li>\n\t<li>Driver load issue existed with Errata-kernel on SLES15 SP1.</li>\n\t<li>An issue in the Hairpin feature which prevented adding hairpin flows using TC tool was fixed.</li>\n\t<li>WQ (Work Queue)&nbsp;queue flushing was not handled properly in the event of EEH.</li>\n\t<li>A rare kernel crash scenario when exiting an application that uses RMPP mads intensively.</li>\n\t<li>A possible kernel crash scenario when AER/slot reset in done in parallel to user space commands execution.</li>\n\t<li>Added missing ECN (Explicit Congestion Notification) configuration under sysfs for PFs in SwitchDev mode.</li>\n\t<li>When firmware response time to commands became very long, some commands failed upon timeout. The driver may have then triggered a timeout completion on the wrong entry, leading to a NULL pointer call trace.</li>\n\t<li>Added driver support for kernels with the old XDP_REDIRECT infrastructure that uses the following NetDev operations: .ndo_xdp_flush and .ndo_xdp_xmit.</li>\n\t<li>Usage of --excludedocs Open MPI RPM option resulted in the removal of non-documentation related files.</li>\n\t<li>Disabled automated loading of some modules through udev triggers to preserve the startup process of previous MLNX_OFED versions.</li>\n\t<li>Reference count (refcount) for RDMA connection ID (cm_id) was not incremented in rdma_resolve_addr() function, resulting in a cm_id use-after-free access. A fix was applied to increment the cm_id refcount</li>\n\t<li>A race condition which caused kernel panic when moving two ports to SwitchDev mode at the same time.</li>\n\t<li>Allowed accessing sysfs hardware counters in SwitchDev mode</li>\n\t<li>Function smp_processor_id() is called in the RX page recycle flow to determine the core to run on. This is intended to run in NAPI context. However, due to a bug in backporting, the RX page recycle was mistakenly called also in the RQ close flow when not needed.</li>\n\t<li>Port link state was automatically changed (without admin state involvement) to &quot;UP&quot; after reboot.</li>\n\t<li>ConnectX-3 adapter cards froze when running over SLES 11 OS.</li>\n\t<li>RDMA CM (Remote Direct Memory Access Communation Manager) connection failed when port space was small.</li>\n\t<li>Traffic mirroring with OVS (Open VSwitch)offload and non-offload over VxLAN interface is now supported. Note: For kernel 4.9, make sure to use a dedicated OVS version.</li>\n\t<li>When working with VF LAG while the bond device is in active-active mode, running fwreset would result in unequal traffic on both PFs, and PFs would not reach line rate.</li>\n\t<li>When bond was created over VF (Virtuaal Function)&nbsp;netdevices in SwitchDev mode, the VF netdevice would be treated as representor netdevice. This caused the mlx5_core driver to crash in case it received netdevice events related to bond device.</li>\n\t<li>An issue where following a bad affinity occurrence in VF LAG mode, traffic was sent after the port went up/down in the switch.</li>\n\t<li>Added support for VLAN (Virtual Local Area Network)&nbsp;header rewrite on CentOS 7.2 OS.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"kmod-mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"kmod-mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWTHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757544841","Version":"HPG3"},{"DeviceName":"VK000960GWTHB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757544842","Version":"HPG3"},{"DeviceName":"VK001920GWTHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757544843","Version":"HPG3"},{"DeviceName":"VK003840GWTHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304757544844","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp; &nbsp;</strong> HPG2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5716627","datemodified":"2021-08-13T14:48:04","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG3-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG3-2.1/CP049276.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG3-2.1/K401HPG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG3-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049276.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049276.scexe"],"md5sum":"f2e46f1ae32259168aa2e8f9109dbe15","name":"firmware-hdd-492a9952f6-HPG3-2.1.x86_64.rpm","release":"2021-08-13T14:35:05","revision":"0","sha1sum":"27bf4001cf12aee2c31a6e9529c245df5705875e","size":"5MB","target_guids":["562340a5-304b-3030-3438-304757544841","562340a5-304b-3030-3936-304757544842","562340a5-304b-3130-3932-304757544843","562340a5-304b-3330-3834-304757544844"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"fde211973c7e4009ac1207f980953529","version":"d2057c35d70840878cfc85c3b7501125"},"installation":{"command":"CP041497.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VK000480GWTHA、VK000960GWTHB、VK001920GWTHCおよびVK003840GWTHDドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VK003840GWTHD","target_guid":"562340a5-304b-3330-3834-304757544844","type":"sata"},{"id":"VK001920GWTHC","target_guid":"562340a5-304b-3130-3932-304757544843","type":"sata"},{"id":"VK000960GWTHB","target_guid":"562340a5-304b-3030-3936-304757544842","type":"sata"},{"id":"VK000480GWTHA","target_guid":"562340a5-304b-3030-3438-304757544841","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-13T14:26:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This maintenance FW release addresses a rare corner case COMRESET issue at warm boot, and to address an early EOL behavior under certain use cases.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK001920GWTHC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GWTHD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWTHA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWTHB","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6887155","datemodified":"2021-05-17T23:30:36","file_list":["/CP047840.vmexe","/CP047840.vmfile","/CP047840.xml","/README.txt"],"md5sum":"f8cb4e3b4f609d93e59da57a3d04b770","name":"CP047840.zip","release":"2021-05-18T04:27:13","revision":"0","sha1sum":"add43a23f104da46cde8895fd65ac8b78d78a4d5","size":"6MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021","vib_list":[]}],"id":{"product":"8dacb77af98a4fc9af98892b534614a5","version":"8e9f912b50fd48c4b1537c6825734264"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component requires that the CRU driver be loaded before the component can run.<br />\nThe minimum CRU version for 5.1 is 5.0.3.9.<br />\nThe minimum CRU version for 5.5 is 5.5.4.1.<br />\nThe minimum CRU version for 6.0 is 6.0.8.<br />\nThe minimum CRU version for 6.5 is 6.5.8.<br />\nThe minimum CRU version for 6.7 is 6.7.10.<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>SPP Offline mode boots a special Linux OS environment, thus the Linux Components are used, not the VMware Components</li>\n</ul>\n\n<p><br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Download the appropriate SPP</li>\n\t<li>Add the component to the SPP</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run&nbsp;SUM</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps to complete the firmware update</li>\n\t<li>Refer to the SPP documentation for detailed instructions at:&nbsp; <a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong><strong>To update firmware from VMware ESXi operating system on target server:</strong> </strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Component ( CPxxxxxx.zip) in a temporary directory</li>\n\t<li>From the same directory, unzip the Component:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>To perform the standalone installation, execute the command:<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>Follow the directions given by the Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system for the firmware update to take effect</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、実行する前にCRUドライバーがロードされている必要があります。<br />\n5.1の最小CRUバージョンは5.0.3.9です。<br />\n5.5の最小CRUバージョンは5.5.4.1です。<br />\n6.0の最小CRUバージョンは6.0.8です。<br />\n6.5の最小CRUバージョンは6.5.8です。<br />\n6.7の最小CRUバージョンは6.7.10です。<br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMwareコンポーネントではなく、Linuxコンポーネントが用いられます</li>\n</ul>\n\n<p><br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします</li>\n\t<li>SPPにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします</li>\n\t<li>SUMを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います</li>\n\t<li>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong> </strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>コンポーネント (CPxxxxxx.zip)を一時ディレクトリに置きます</li>\n\t<li>同じディレクトリからコンポーネントをunzipします:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>スタンドアロンのインストールを行うために、次のコマンドを実行します：<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>コンポーネントの指示に従います</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n\t<li>システムを再起動し、ファームウェアのアップデートを有効にします</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware - HPE ProLiant XL450 Gen9 (U21) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for VMware - HPE ProLiant XL450 Gen9（U21）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"5","minor":"1","name":"VMware vSphere 5.1","platform":"vmware_esx_server","sr":"OEM"},{"major":"5","minor":"5","name":"VMware vSphere 5.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-05T03:31:04","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"}],"sw_keys":[{"name":"U21","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWFUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SELD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a57465556","Version":"HPD4"},{"DeviceName":"EG001200JWFVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SELD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3230-304a57465641","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EG000600JWFUV and EG001200JWFVA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG000600JWFUV and EG001200JWFVA Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"16016119","datemodified":"2021-08-30T04:02:45","file_list":["/CP048250_BUILD_2.data","/CP048250.vmexe","/CP048250.vmexe64","/CP048250.vmfile","/CP048250_VMw.zip","/CP048250.xml","/payload.json","/CP048250_VMw.zip/index.xml","/CP048250_VMw.zip/vendor-index.xml","/CP048250_VMw.zip/metadata.zip","/CP048250_VMw.zip/vib20/CP048250/HPE_bootbank_CP048250_HPD4.2-7.0.0.15843807.vib","/CP048250_VMw.zip/metadata.zip/vendor-index.xml","/CP048250_VMw.zip/metadata.zip/vmware.xml","/CP048250_VMw.zip/metadata.zip/vibs/CP048250--382686179823328467.xml","/CP048250_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048250_HPD4.2-7.0.0.15843807.xml"],"md5sum":"dcac49583a97b50142fe40e7977c8aaf","name":"CP048250.zip","release":"2021-08-30T03:58:17","revision":"0","sha1sum":"03f9be79813cc398f10cf247bfdde0b3a824b233","size":"15MB","target_guids":["452340a5-3047-3030-3630-304a57465556","452340a5-3047-3130-3230-304a57465641"],"type_of_change":"1","version":"HPD4","vib_list":[{"name":"CP048250","version":"HPD4.2-7.0.0.15843807"}]}],"id":{"product":"239d1dd26f2c4614bfcd9033d0a83734","version":"32a53b800ff54bc98da59936155f031c"},"installation":{"command":"CP040635.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - EG000600JWFUV and EG001200JWFVA Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - EG000600JWFUVおよびEG001200JWFVAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG001200JWFVA","target_guid":"452340a5-3047-3130-3230-304a57465641","type":"sas"},{"id":"EG000600JWFUV","target_guid":"452340a5-3047-3030-3630-304a57465556","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-02T05:53:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>A low-probability, high severity corner case of sustained outer-diameter activity with emergency power off when heads are at the outer diameter prevented heads from parking/latching properly on a few drives in the field.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001200JWFVA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG000600JWFUV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component contains version 9.4.1.20 of the QLogic Storport driver which provides Fibre Channel-Host Bus Adapter driver support for HPE storage arrays."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1433672","datemodified":"2021-08-27T03:44:45","file_list":["cp049108.xml","cpqsetup.exe","install.xml","ql2300.cat","ql2300.sys","ql2x00.inf","QLOGIC","qlsrvc.exe","QlStorInstaller.dll","readme.txt","release.txt","SysConfig.frm","SysConfig.frm.ja","txtsetup.oem"],"md5sum":"767c81fca52d8492a573bc86b89353c1","name":"cp049108.exe","release":"2021-08-27T03:41:40","revision":"0","sha1sum":"0eaa552646df51c0babc390408fb896e878d239a","size":"1MB","target_guids":[],"type_of_change":"1","version":"9.4.1.20"}],"id":{"product":"34ee6d7eb6f54800b660e06b318b3d95","version":"3814a099171e49d68f38baff472a104f"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br />\n<br />\nFrom that drive and directory, execute the downloaded file.<br />\n<br />\nClick the &quot;Install&quot; button to proceed with the installation.<br />\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Fibre Channel Adapter Kit for the x64 QLogic Storport Driver for Microsoft Windows Server 2012R2"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015D","subven":"1077","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015C","subven":"1077","target_guid":"","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-23T06:41:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Made improvements to the Fabric Port Identification Number (FPIN) and Universal Storage Area Network (SAN) Congestion Mitigation (USCM) Congestion Management algorithms.</li>\n</ul>\n\n<p>Updated&nbsp;to&nbsp;version 9.4.1.20</p>\n","curr_fixes_x_late":"<ul>\n\t<li>Removed the &quot;fwload&quot; registry parameter.</li>\n\t<li>Fixed an unwanted behavior where Link up/down messages were not always logged in the Window System Event log.</li>\n\t<li>Fixed unwanted behavior with the reporting of Fabric Port Identification Number (FPIN) and Universal Storage Area Network (SAN) Congestion Mitigation (USCM) statistics.</li>\n\t<li>Fixed an unwanted behavior where connections to tape drives may fail to recover in the event of &quot;SCSI Check Condition&quot; commands or cable pulls.</li>\n\t<li>Fixed an unwanted behavior where the server may encounter a Blue Screen Of Death (BSOD) 0x0000009f message during shutdown as described in <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00116202en_us\">Advisory: HPE Host Bus Adapters - HPE Platforms Running a Microsoft Windows Server 2016 / 2019 Hyper-V Environment, and Configured With Certain HPE HBAs With the QLogic Storport Driver v9.4.2.20, May Experience a Bug Check 0x9F Event</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"ql2300.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"8695816","datemodified":"2021-05-17T18:14:35","file_list":["/CP047769.vmexe","/CP047769.vmexe64","/CP047769.vmfile","/CP047769.xml","/README.txt"],"md5sum":"48f91a6e6343c1ce094930bf82c9521c","name":"CP047769.zip","release":"2021-05-17T23:11:04","revision":"0","sha1sum":"0d86d3c1ac5e092c2e3a93d0f652906b1b613d40","size":"8MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021","vib_list":[]}],"id":{"product":"30164e5ab9734a16a82806757516cba6","version":"ad4e9a77f18748e2b6206e2f041d36f0"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component requires that the CRU driver be loaded before the component can run.<br />\nThe minimum CRU version for 5.1 is 5.0.3.9.<br />\nThe minimum CRU version for 5.5 is 5.5.4.1.<br />\nThe minimum CRU version for 6.0 is 6.0.8.<br />\nThe minimum CRU version for 6.5 is 6.5.8.<br />\nThe minimum CRU version for 6.7 is 6.7.10.<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>SPP Offline mode boots a special Linux OS environment, thus the Linux Components are used, not the VMware Components</li>\n</ul>\n\n<p><br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Download the appropriate SPP</li>\n\t<li>Add the component to the SPP</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run SUM</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps to complete the firmware update</li>\n\t<li>Refer to the SPP documentation for detailed instructions at:&nbsp; <a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Component ( CPxxxxxx.zip) in a temporary directory</li>\n\t<li>From the same directory, unzip the Component:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>To perform the standalone installation, execute the command:<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>Follow the directions given by the Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system for the firmware update to take effect</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、実行する前にCRUドライバーがロードされている必要があります。<br />\n5.1の最小CRUバージョンは5.0.3.9です。<br />\n5.5の最小CRUバージョンは5.5.4.1です。<br />\n6.0の最小CRUバージョンは6.0.8です。<br />\n6.5の最小CRUバージョンは6.5.8です。<br />\n6.7の最小CRUバージョンは6.7.10です。<br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMwareコンポーネントではなく、Linuxコンポーネントが用いられます</li>\n</ul>\n\n<p><br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします</li>\n\t<li>SPPにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします</li>\n\t<li>SUMを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います</li>\n\t<li>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>コンポーネント (CPxxxxxx.zip)を一時ディレクトリに置きます</li>\n\t<li>同じディレクトリからコンポーネントをunzipします:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>スタンドアロンのインストールを行うために、次のコマンドを実行します：<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>コンポーネントの指示に従います</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n\t<li>システムを再起動し、ファームウェアのアップデートを有効にします</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware - HPE ProLiant BL660c Gen9 (I38) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for VMware - HPE ProLiant BL660c Gen9（I38）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"5","minor":"1","name":"VMware vSphere 5.1","platform":"vmware_esx_server","sr":"OEM"},{"major":"5","minor":"5","name":"VMware vSphere 5.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-29T16:12:26","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>Ver. 2.80_10-16-2020 (B)&nbsp; contains updates to the component packaging and is functionally equivalent to ver. 2.80_10-16-2020.&nbsp; It is not necessary to upgrade with Revision B if a previous component Revision was used to upgrade the system ROM to version 2.80_10-16-2020.</p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"}],"sw_keys":[{"name":"I38","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EK000200GWEPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3030-3230-304757455044","Version":"HPG3"},{"DeviceName":"EK000400GWEPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3030-3430-304757455045","Version":"HPG3"},{"DeviceName":"EK000800GWEPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3030-3830-304757455046","Version":"HPG3"},{"DeviceName":"EK001600GWEPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3130-3630-304757455048","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EK000200GWEPD, EK000400GWEPE, EK000800GWEPF and EK001600GWEPH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - EK000200GWEPD, EK000400GWEPE, EK000800GWEPFand EK001600GWEPH Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"2810008","datemodified":"2021-07-24T05:02:46","file_list":["cp048554.xml","cpqsetup.exe","GS865aG3.rel","payload.json","setup.dll"],"md5sum":"6be83a8e622de3e3167e8b5e89fb587b","name":"cp048554.exe","release":"2021-07-24T04:55:04","revision":"0","sha1sum":"b00b8417f156c66cacd975118f8bbc917a778700","size":"2MB","target_guids":["452340a5-304b-3030-3230-304757455044","452340a5-304b-3030-3430-304757455045","452340a5-304b-3030-3830-304757455046","452340a5-304b-3130-3630-304757455048"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"249ebde928b24f7cb7ebdd3c20053940","version":"8535c17f50464add8ef2d199a6ba64a0"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"text-decoration-line: none; color: blue;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EK000200GWEPD, EK000400GWEPE, EK000800GWEPF and EK001600GWEPH Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EK000200GWEPD、EK000400GWEPE、EK000800GWEPFおよびEK001600GWEPHドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EK000400GWEPE","target_guid":"452340a5-304b-3030-3430-304757455045","type":"sata"},{"id":"EK000800GWEPF","target_guid":"452340a5-304b-3030-3830-304757455046","type":"sata"},{"id":"EK001600GWEPH","target_guid":"452340a5-304b-3130-3630-304757455048","type":"sata"},{"id":"EK000200GWEPD","target_guid":"452340a5-304b-3030-3230-304757455044","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T05:02:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EK000800GWEPF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"EK000400GWEPE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"EK000200GWEPD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"EK001600GWEPH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]},{"key":"7800374","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"en","x_late":"This package contains utilities and libraries to enable HPE Storage fibre channel array connectivity on SUSE Linux Enterprise Server 12 for Emulex Host Bus Adapters and Mezzanine Host Bus Adapters"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1790191","datemodified":"2021-08-26T07:59:30","file_list":["./opt/emulex/sles12sp5/i386/lib/libdfc.so","./opt/emulex/sles12sp5/i386/lib/libdfc.so.12","./opt/emulex/sles12sp5/i386/lib/libdfc.so.12.8.526","./opt/emulex/sles12sp5/i386/lib/libemsdm.so","./opt/emulex/sles12sp5/i386/lib/libemulexhbaapi.so","./opt/emulex/sles12sp5/x86_64/lib64/libdfc.so","./opt/emulex/sles12sp5/x86_64/lib64/libdfc.so.12","./opt/emulex/sles12sp5/x86_64/lib64/libdfc.so.12.8.526","./opt/emulex/sles12sp5/x86_64/lib64/libemsdm.so","./opt/emulex/sles12sp5/x86_64/lib64/libemulexhbaapi.so","./usr/lib/libdfc.so","./usr/lib/libdfc.so.12","./usr/lib/libdfc.so.12.8.526","./usr/lib/libemsdm.so","./usr/lib/libemulexhbaapi.so","./usr/lib64/libdfc.so","./usr/lib64/libdfc.so.12","./usr/lib64/libdfc.so.12.8.526","./usr/lib64/libemsdm.so","./usr/lib64/libemulexhbaapi.so","./usr/share/smartupdate/HPE-CNA-FC-Emulex-Enablement-Kit/component.xml"],"md5sum":"308334a9a650edb61f913f1c9097e0fd","name":"HPE-CNA-FC-Emulex-Enablement-Kit-12.8.526.0-1.sles12sp5.x86_64.rpm","release":"2021-08-26T07:48:04","revision":"0","sha1sum":"9423576229ace11646b672cee7e4f7c2695bfa32","size":"1MB","target_guids":[],"type_of_change":"0","version":"12.8.526.0"}],"id":{"product":"dfd82a39b7064323ae96b071235ff1cf","version":"14a717f9a4174dbfb4772108f225c80d"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The target environment must have the libHBAAPI Package installed prior to the installation of the enablement kit. (If not already present, the libHBAAPI Package can be obtained from the operating system installation media.)</p>\n\n<p>&nbsp;</p>\n\n<p>This version of the enablement kit does not provide the additional functionality of rebuilding the ram disk or setting driver parameters as the previous versions had done.&nbsp; Please refer to the &ldquo;Additional setup&rdquo; section of the Native Linux Device-Mapper Multipath for HPE StorageWorks Arrays reference guide for instructions on how to perform these functions.&nbsp; The reference guide is available at the following link:</p>\n\n<p><a href=\"http://www.hpe.com/storage/spock/\">http://www.hpe.com/storage/spock/</a></p>\n\n<p>Rewrite of same Enablement kit version on&nbsp;SuSE Linux Enterprise Server 12 service pack 5 has to be performed using &ndash;force or --replacepkgs with --nodeps option</p>\n\n<p>Example:&nbsp;rpm &ndash;Uvh HPE-CNA-FC-Emulex-Enablement-Kit-&lt;version&gt;.&lt;OS&gt;.&lt;architecture&gt;.rpm --force --nodeps</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;rpm &ndash;Uvh HPE-CNA-FC-Emulex-Enablement-Kit-&lt;version&gt;.&lt;OS&gt;.&lt;architecture&gt;.rpm --replacepkgs --nodeps</p>\n\n<p>&nbsp;For more information please refer the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex Fibre Channel Enablement Kit for Host Bus Adapters and Mezzanine Host Bus Adapters for SUSE Linux Enterprise Server 12"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"F100","subven":"10DF","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T10:35:58","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to version 12.8.526.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"HPE-CNA-FC-Emulex-Enablement-Kit","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960KXAVL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304b5841564c","Version":"HPK3"},{"DeviceName":"VO001920KXAVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304b58415650","Version":"HPK3"},{"DeviceName":"VO003840KXAVQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304b58415651","Version":"HPK3"},{"DeviceName":"VO007680KXAVR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304b58415652","Version":"HPK3"},{"DeviceName":"MO000800KXAVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304b5841564e","Version":"HPK3"},{"DeviceName":"MO001600KXAVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b58415654","Version":"HPK3"},{"DeviceName":"MO003200KXAVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b58415655","Version":"HPK3"},{"DeviceName":"MO006400KXAVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b58415656","Version":"HPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Linux (x64) - VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp; HPK3</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPK2</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPK2</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>This Firmware release contains various drive interoperability enhancements and code fixes accumulated since the last firmware release, as well as a change to disable MCTP over PCIe VDM function per requested of HPE, and a PHY setting change for improved compatibility with Intel Ice Lake based Gen10+ DL360 platform.&nbsp;</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00115201en_us</li>\n</ul>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p dir=\"rtl\">&nbsp;</p>\n"}],"files":[{"bytes":"7744760","datemodified":"2021-08-17T13:28:37","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK3-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK3-2.1/CP049304.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK3-2.1/KPE80X0AHPK3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK3-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049304.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049304.scexe"],"md5sum":"ed1b7e1d865e6ede8ca523fcb687e70e","name":"firmware-hdd-035a863453-HPK3-2.1.x86_64.rpm","release":"2021-08-17T13:14:05","revision":"0","sha1sum":"bd0f130c4a0ca3e7bbc3fb54e3ff1bb832d1866c","size":"7MB","target_guids":["562340a5-304f-3030-3936-304b5841564c","562340a5-304f-3130-3932-304b58415650","562340a5-304f-3330-3834-304b58415651","562340a5-304f-3730-3638-304b58415652","4d2340a5-304f-3030-3830-304b5841564e","4d2340a5-304f-3130-3630-304b58415654","4d2340a5-304f-3330-3230-304b58415655","4d2340a5-304f-3630-3430-304b58415656"],"type_of_change":"2","version":"HPK3"}],"id":{"product":"fdd1b58860474c42b7f3b1b7524af387","version":"1a3c729a891943d280530fccb58fd498"},"installation":{"command":"CP042953.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p><strong>Additional Information:</strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p><strong>追加情報:</strong></p>\n\n<p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - VO000960KXAVL、VO001920KXAVP、VO003840KXAVQ、VO007680KXAVR、MO000800KXAVN、MO001600KXAVT、MO003200KXAVU、MO006400KXAVVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VO000960KXAVL","target_guid":"562340a5-304f-3030-3936-304b5841564c","type":"nvme"},{"id":"MO000800KXAVN","target_guid":"4d2340a5-304f-3030-3830-304b5841564e","type":"nvme"},{"id":"MO001600KXAVT","target_guid":"4d2340a5-304f-3130-3630-304b58415654","type":"nvme"},{"id":"MO003200KXAVU","target_guid":"4d2340a5-304f-3330-3230-304b58415655","type":"nvme"},{"id":"MO006400KXAVV","target_guid":"4d2340a5-304f-3630-3430-304b58415656","type":"nvme"},{"id":"VO003840KXAVQ","target_guid":"562340a5-304f-3330-3834-304b58415651","type":"nvme"},{"id":"VO007680KXAVR","target_guid":"562340a5-304f-3730-3638-304b58415652","type":"nvme"},{"id":"VO001920KXAVP","target_guid":"562340a5-304f-3130-3932-304b58415650","type":"nvme"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-17T13:09:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This Firmware release contains various drive interoperability enhancements and code fixes accumulated since the last firmware release, as well as a change to disable MCTP over PCIe VDM function per requested of HPE, and a PHY setting change for improved compatibility with Intel Ice Lake based Gen10+ DL360 platform.&nbsp;</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00115201en_us</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This Firmware release contains various drive interoperability enhancements and code fixes accumulated since the last firmware release, as well as a change to disable MCTP over PCIe VDM function per requested of HPE, and a PHY setting change for improved compatibility with Intel Ice Lake based Gen10+ DL360 platform.&nbsp;</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00115201en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO007680KXAVR","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO006400KXAVV","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO001600KXAVT","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO001920KXAVP","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO000960KXAVL","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO003840KXAVQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO003200KXAVU","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO000800KXAVN","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GEXXV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRETG2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745585856","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB6000GEXXV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB6000GEXXV Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp;</strong> None</p>\n"}],"files":[{"bytes":"3396136","datemodified":"2021-07-25T18:14:11","file_list":["cp048633.xml","cpqsetup.exe","payload.json","setup.dll","TTMRETG2.REL"],"md5sum":"06707539232732b4b5bbeca98ecf6f66","name":"cp048633.exe","release":"2021-07-25T18:07:11","revision":"0","sha1sum":"92b015b0b0d296b84ea49e4f559f5e0ea1115e8d","size":"3MB","target_guids":["002340a5-4d00-3642-3030-304745585856"],"type_of_change":"1","version":"HPG2"}],"id":{"product":"835ec029c284401691cf43baf128212e","version":"c9510f3ac6f24818a7c8e28aa8c0b6c4"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB6000GEXXV Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB6000GEXXVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB6000GEXXV","target_guid":"002340a5-4d00-3642-3030-304745585856","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T14:42:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000GEXXV","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"Online Smart Component which upgrades the enclosure firmware on the HPE Apollo 45xx Gen9 Backplane Expanders"},{"lang":"cn","x_late":"更新HPE Apollo 45xx Gen9背板扩展卡机箱固件的在线智能组件"},{"lang":"tw","x_late":"可升級 HPE Apollo 45xx Gen9 背板擴充卡上機櫃韌體的線上智慧型元件"},{"lang":"ko","x_late":"HPE Apollo 45xx Gen9 백플레인 익스팬더에서 인클로저 펌웨어를 업그레이드하는 온라인 스마트 구성요소"},{"lang":"ja","x_late":"HPE Apollo 45xx Gen9バックプレーンエキスパンダー上のエンクロージャーファームウェアをアップグレードするオンラインSmartコンポーネント"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for VMware ESXi &ndash; HPE Apollo 45xx Gen9 Backplane Expander Firmware</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;2.51<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;2.50<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;2.50<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>&nbsp;Drive may show up&nbsp;missing after a system reboot.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"},{"lang":"ja","x_late":"<p><strong>提供名：</strong><br />\n     オンラインROMフラッシュコンポーネント for VMware ESXi - HPE Apollo 45xx Gen9バックプレーンエキスパンダーファームウェア</p>\n\n<p><strong>リリースバージョンおよび/または日付:</strong><br />\n     2.51<br />\n<br />\n<strong>最新の推奨またはクリティカルバージョン:</strong><br />\n     2.50<br />\n<br />\n<strong>前のファームウェアバージョン:</strong><br />\n     2.50<br />\n<br />\n<strong>ファームウェアの関連性:</strong><br />\n     なし        <br />\n<br />\n<strong>改善点/新しい機能：</strong></p>\n\n<p>     なし\n        </p>\n\n<p><strong>修正された問題点：</strong></p>\n\n<ul>\n\t<li> システムの再起動後にドライブが表示されない場合があります。</li>\n</ul>\n\n<p><strong>既知の問題点:</strong><br />\n     なし        </p>\n"}],"files":[{"bytes":"11635134","datemodified":"2020-03-16T13:47:08","file_list":["/CP043496.vmexe","/CP043496.vmfile","/CP043496.xml","/payload.json","/README.txt"],"md5sum":"6336d7622e215e76d77bdbec5a1a5d93","name":"CP043496.zip","release":"2020-03-16T00:00:00","revision":"1","sha1sum":"1e869ad8d67144009e4f243f064f81874c639f14","size":"11MB","target_guids":[],"type_of_change":"1","version":"2.51","vib_list":[]}],"id":{"product":"21e4b5b75bfd4055af20a7109d8d2e08","version":"794badeeb0004dedaa4f4b86db89937d"},"installation":{"command":"CP038042.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><u>Please&nbsp;un-plug and re-plug the power cord to the server for firmware upgrade from version 1.03&nbsp;or earlier to take effect.&nbsp;</u></p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a>&nbsp;on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at: <a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;<br />\n<strong>To use HP Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HP Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n\t<li>Reboot your system, for the firmware update to take effect.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><u>バージョン1.03以前からのファームウェアアップグレードを有効にするために、サーバーの電源コードを1度抜いて、再度挿してください。 </u></p>\n\n<p><strong>HP Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン (</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用します<strong>)：</strong></p>\n\n<ul>\n\t<li><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/hp/swpackagesディレクトリにコピーします。</li>\n\t<li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li>\n\t<li>HP Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン：</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加しました。</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>HP Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hp.com/go/spp</a><br />\n <br />\n<strong>HP Insight Control for vCenterを使用するには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>vSphereクライアントにログインします。</li>\n\t<li>インベントリツリーのサーバーまたはクラスターを選択します。</li>\n\t<li>HP Insight Managementタブをクリックします。</li>\n\t<li>Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルをテンポラリディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします</li>\n\t<li>コマンドを使用してCPXXXXXX.vmexeが実行可能であることを確認します：</li>\n</ul>\n\n<p>             chmod +x CPXXXXXX.vmexe    </p>\n\n<ul>\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例：./CPXXXXXX.vmexe</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします。</li>\n\t<li>ファームウェアアップデートを有効にするためにシステムを再起動します。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware ESXi – HPE Apollo 45xx Gen9 Backplane Expander Firmware "},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor VMware ESXi - HPE Apollo 45xx Gen9バックプレーンエキスパンダーファームウェア "}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_operating_systems":[{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-05-02T14:37:29","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Drive may show up&nbsp;missing after a system reboot.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Drive may show up&nbsp;missing after a system reboot.</p>\n\n<p>Please reference Customer Advisory a00098241en_us</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"Carbondale14","value":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"key":"Carbondale14","value":"<p>HPE Apollo 4520 Gen9 Chassis</p>\n"},{"key":"Carbondale14","value":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>\n"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"}],"sw_keys":[{"name":"HP Apollo 4530","sw_key_expectedpath":"firmware:sd:sasexpander"},{"name":"HP Apollo 4520","sw_key_expectedpath":"firmware:sd:sasexpander"},{"name":"HP Apollo 4510","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 adapter cards."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1633935","datemodified":"2021-07-21T06:40:26","file_list":["./etc/depmod.d/zz01-mlnx-ofa_kernel-auxiliary.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-bnxt_re.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-cifs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-efa.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-hfi1.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-i40iw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ipoib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_iser.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_isert.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srp.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srpt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_umad.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_uverbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cxgb4.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx_compat.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxdevm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxfw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvme-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvmet-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-opa_vnic.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-qedr.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_rxe.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdmavt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rpcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-siw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-svcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-usnic_verbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-vmw_pvrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-xprtrdma.conf","./lib/modules/4.18.0-305.el8.x86_64","./lib/modules/4.18.0-305.el8.x86_64/extra","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/compat","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/compat/mlx_compat.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/base","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/base/auxiliary.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_cm.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_core.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_ucm.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_umad.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/iw_cm.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_cm.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa/efa.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/i40iw","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/siw","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/siw/siw.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host/nvme-rdma.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/fs","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/fs/cifs","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/fs/cifs/cifs.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/net","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/net/mlxdevm","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/net/mlxdevm/mlxdevm.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/kmod-mlnx-ofa_kernel/component.xml"],"md5sum":"508c3b4a9a024893994fedade29cc19e","name":"kmod-mlnx-ofa_kernel-5.4-OFED.5.4.1.0.3.1.rhel8u4.x86_64.rpm","release":"2021-07-21T05:43:07","revision":"0","sha1sum":"65b0e2ed2dfed6d5e7968effc43f17d4810a54c3","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"5.4"},{"bytes":"1358159","datemodified":"2021-07-21T06:43:13","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/rdma","./etc/rdma/mlx4.conf","./etc/rdma/modules","./etc/rdma/modules/rdma.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/70-persistent-ipoib.rules","./lib/udev/auxdev-sf-netdev-rename","./lib/udev/mlnx_bf_udev","./lib/udev/rules.d/82-net-setup-link.rules","./lib/udev/rules.d/83-mlnx-sf-name.rules","./lib/udev/rules.d/90-ib.rules","./lib/udev/sf-rep-netdev-rename","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/mlnx_bf_configure_ct","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_perf","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/include/mellanox/dpcp.h","./usr/lib/.build-id","./usr/lib/.build-id/05","./usr/lib/.build-id/05/86cae08c1b01d0f8ad24e6480cc377b624f957","./usr/lib/.build-id/10","./usr/lib/.build-id/10/e97577971768051eb337450f77618ca0a5d0e6","./usr/lib/.build-id/2e","./usr/lib/.build-id/2e/d00dbf64950b632ae926e7969e7a51fcb41d50","./usr/lib/.build-id/51","./usr/lib/.build-id/51/23bd2c9955511ac59d99f0c3d38ca2d865a098","./usr/lib/.build-id/88","./usr/lib/.build-id/88/9763acb4d629208394da12a940b6fc2fa6d9e8","./usr/lib/.build-id/8e","./usr/lib/.build-id/8e/ecb52ea7443490e1d12638709f51b1bc9a6461","./usr/lib/.build-id/bf","./usr/lib/.build-id/bf/6991e6ef41e153cdb89927b753ed55d19a2dda","./usr/lib/.build-id/d8","./usr/lib/.build-id/d8/d5b8ca5bdc50ace9f2691e8d3ac75d68e2867e","./usr/lib/.build-id/da","./usr/lib/.build-id/da/da43be376b1e57f30c17e166d6061d0744161d","./usr/lib/.build-id/f5","./usr/lib/.build-id/f5/b746c3a36d81b679443335ff27658f8938a91a","./usr/lib/dracut","./usr/lib/dracut/modules.d","./usr/lib/dracut/modules.d/05rdma","./usr/lib/dracut/modules.d/05rdma/module-setup.sh","./usr/lib/modprobe.d","./usr/lib/modprobe.d/libmlx4.conf","./usr/lib/python3.6/site-packages/dcbnetlink.py","./usr/lib/python3.6/site-packages/genetlink.py","./usr/lib/python3.6/site-packages/mlnx_tools-5.2.0-py3.6.egg-info","./usr/lib/python3.6/site-packages/netlink.py","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/rdma-ndd.service","./usr/lib/systemd/system/vma.service","./usr/lib/udev/rdma_rename","./usr/lib/udev/rules.d","./usr/lib/udev/rules.d/60-rdma-ndd.rules","./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules","./usr/lib/udev/rules.d/75-rdma-description.rules","./usr/lib/udev/rules.d/90-rdma-umad.rules","./usr/lib64/libdpcp.so","./usr/lib64/libdpcp.so.1","./usr/lib64/libdpcp.so.1.1.12","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.35.0","./usr/lib64/libibverbs","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.14.35.0","./usr/lib64/libibverbs/libmlx5-rdmav34.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.19.35.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.3.35.0","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.3.1","./usr/lib64/rsocket","./usr/lib64/rsocket/librspreload.so","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/libexec/mlx4-setup.sh","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/ibdev2netdev","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/rdma-ndd","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vmad","./usr/share/doc/dpcp","./usr/share/doc/dpcp/README","./usr/share/doc/libibverbs","./usr/share/doc/libibverbs/libibverbs.md","./usr/share/doc/librdmacm","./usr/share/doc/librdmacm/librdmacm.md","./usr/share/doc/libvma","./usr/share/doc/libvma/CHANGES","./usr/share/doc/libvma/README","./usr/share/doc/mlnx-tools","./usr/share/doc/mlnx-tools/ib2ib_setup.txt","./usr/share/doc/rdma-core","./usr/share/doc/rdma-core/COPYING.BSD_FB","./usr/share/doc/rdma-core/COPYING.BSD_MIT","./usr/share/doc/rdma-core/COPYING.GPL2","./usr/share/doc/rdma-core/COPYING.md","./usr/share/doc/rdma-core/README.md","./usr/share/doc/rdma-core/tag_matching.md","./usr/share/doc/rdma-core/udev.md","./usr/share/licenses/dpcp","./usr/share/licenses/dpcp/LICENSE","./usr/share/licenses/libvma","./usr/share/licenses/libvma/COPYING","./usr/share/man/man7/rsocket.7.gz","./usr/share/man/man7/vma.7.gz","./usr/share/man/man8/ib2ib_setup.8.gz","./usr/share/man/man8/rdma-ndd.8.gz","./usr/share/man/man8/vmad.8.gz","./usr/share/mlnx_ofed/mlnx_bf_assign_ct_cores.sh","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml","./usr/lib/python3.6/site-packages/__pycache__/dcbnetlink.cpython-36.opt-1.pyc","./usr/lib/python3.6/site-packages/__pycache__/dcbnetlink.cpython-36.pyc","./usr/lib/python3.6/site-packages/__pycache__/genetlink.cpython-36.opt-1.pyc","./usr/lib/python3.6/site-packages/__pycache__/genetlink.cpython-36.pyc","./usr/lib/python3.6/site-packages/__pycache__/netlink.cpython-36.opt-1.pyc","./usr/lib/python3.6/site-packages/__pycache__/netlink.cpython-36.pyc"],"md5sum":"64d24a1ae05d98168bd0dc750a47fe52","name":"mlnx-ofa_kernel-5.4-OFED.5.4.1.0.3.1.rhel8u4.x86_64.rpm","release":"2021-07-21T05:43:07","revision":"0","sha1sum":"b5f764e772e542fa92cf91872d725b63111c9ee8","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"5.4"}],"id":{"product":"0531c6d1fe1a4b698169f8dcb578d331","version":"61e36256bd3f4b4496421962119b6a47"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)","OSVersion":{"name":"Linux","value":"6.9"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)","OSVersion":{"name":"Linux","value":"6.10"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)","OSVersion":{"name":"Linux","value":"7.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)","OSVersion":{"name":"Linux","value":"7.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-5.4&quot;&nbsp;RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using kernel version 4.18.0-305.el8.x86_64&nbsp;or any future errata:<br />\n<br />\n<strong># rpm -Uvh&nbsp;kmod-mlnx-ofa_kernel-5.4-OFED.5.4-0.5.1.1.rhel8u4.x86_64.rpm mlnx-ofa_kernel-5.4-OFED.5.4-0.5.1.1.rhel8u4.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 Adapters for Red Hat Enterprise Linux 8 Update 4 (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"101f","subdev":"0012","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30012","type":"pci","ven":"15b3"},{"dev":"101f","subdev":"0007","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30007","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"032D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-10171590032d","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T17:11:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>Changes and new features in HPE Mellanox RoCE driver&nbsp;version 5.3:</strong></p>\n\n<p><strong>For ConnectX-5 Adapters and above:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>CQE compression support for Rx multi-strides packets.</li>\n\t\t<li>Configuring QoS on a single QP or on a group of QPs.</li>\n\t\t<li>Encap/decap hardware offload of IPv4 traffic over MPLS-over-UDP. This can be used in networks with MPLS routers to achieve more efficient routing.</li>\n\t\t<li>Connection tracking rules on VFs to forward traffic from one VF to the other.</li>\n\t\t<li>Offloading sFlow sampling rules.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For ConnectX-5 Adapters and ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>A locking mechanism to enable parallel insertion of rules into the software steering using the mlx5dv_dr API. The parallel insertion improves the insertion rate and takes place when adding Rx and Tx rules via the FDB domain.</li>\n\t\t<li>Option to match mlx5dv_dr API on Geneve tunnel using a dynamic flex parser. The option header consists of class, type, length and data. The parser should be configured using devx command, after which a rule can be created to match on parser ID and data.</li>\n\t\t<li>Geneve tunneling offload, including matching on extension header.</li>\n\t\t<li>Parallel insertion and deletion of offloaded rules using multiple&nbsp;OVS threads.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>[Beta] Modify GTP-U TEID. This support requires flex parser&nbsp;configuration.</li>\n\t\t<li>[Beta] Improved performance of OVS Connection Tracking flows by&nbsp;enabling the merge of the multi-table flow matches and actions into one joint flow.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Dx Adapters and above:</strong></p>\n\n<p>Added support for the following features:</p>\n\n<ul>\n\t<li>Transmitted packet timestamping accuracy can be improved when using a timestamp generated at the port level instead of a timestamp generated upon CQE creation. Tx port time-stamping better reflects the actual time of a packet&#39;s transmission. This feature is disabled by default. The feature can be enabled or disabled using the following command. ethtool --set-priv-flags tx_port_ts on / off.</li>\n\t<li>Offloading tunnel rules when the source interface is VF (in addition to uplink) in the Hypervisor.</li>\n\t<li>Using Mirroring Offload with Connection Tracking.</li>\n\t<li>ASO flow meter using the mlx5dv_dr API, which allows for monitoring the packet rate for specific flows. When a packet hits a flow that is connected to a flow meter, the rate of packets through this meter is evaluated, and the packet is marked with a color copied into one of the C registers, according to the current rate compared to the reference rate.</li>\n\t<li>ASO first hit using the mlx5dv_dr API, which allows for tracking rule hits by packets. When a packet hits a rule with the ASO first hit action, a flag is set indicating this event, and the original value of the flag is copied to one of the C registers.</li>\n\t<li>mlx5dv_dr API support for matching on a new field &quot;gtpu_first_ext_dw_0&quot;. This field enables packet filtering based on the GTP-U first extension header (first dword only). To enable parsing of tunnel GTP-U extension header, run the following command. ./cloud_fw_reset.py FLEX_PARSER_PROFILE_ENABLE=3.</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Lx Adapters and above:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>IPsec full offload support for extended sequence number, replay protection window and lifetime packet limit.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;All HCA&#39;s:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>New query GID API that allows for querying a single GID entry by its port and GID index, or querying for all GID tables of a specific device. This API works over ioctl instead of sysfs, which accelerates the querying process.</li>\n\t\t<li>Performing multi-host firmware reset in order to upgrade the device firmware. Firmware reset loads the new firmware in case it was burnt on the flash and was pending activation, and reload.</li>\n\t\t<li>[Alpha] Firmware live patching in the driver. Live patching updates the firmware without the need to perform firmware reset. However, it can only be applied in scenarios where the difference between the current and new firmware versions are minor, which is decided upon by the firmware itself.</li>\n\t\t<li>devlink tool for performing firmware reset in order to upgrade the device firmware. Firmware reset loads the new firmware in case it was burnt on the flash and was pending activation, and reloads the current firmware image from the flash in case no new firmware was pending. For further information, please refer to the the devlink man page.</li>\n\t\t<li>A resiliency mechanism for the driver to manually poll the command event queue (EQ) in case of a command timeout. In case the resiliency mechanism finds unhandled event queue entry (EQE) due to a lost interrupt, the driver will handle it, after which the command interface returns to a healthy state.</li>\n\t\t<li>Setting a sniffer private flag is deprecated and no longer required. In order to capture offloaded/RoCE traffic, tcpdump can now be run on the RDMA device.</li>\n\t\t<li>Added per-port reporters to devlink health to manage per-port health activities. Users can now access the devlink port reporters by specifying the port index in addition to the device devlink name through the devlink health commands API. This update was first introduced in iproute2 v5.8. As part of this feature, mlx5e Tx and Rx reporters are now redefined as devlink port reporters. For examples, please see devlink-health manpage</li>\n\t\t<li>Optimized memory consumption of memory registration in huge page systems. As an example, in a 2MB huge page system, 600 MB would be saved for 100 GB memory registration.</li>\n\t\t<li>mlx5dv API to modify the configured UDP source port for RoCE packets of a given RC/UC QP when QP is in RTS state.</li>\n\t\t<li>Accelerating Tx datapath by saving PCI bandwidth and CPU utilization. The savings are achieved by aggregating multiple packets into a single WQE. The feature is driven by xmit_more for certain traffic types, such as UDP.</li>\n\t</ul>\n\t</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 5.3:</strong></p>\n\n<ul>\n\t<li>Clearing min_rate on all SR-IOV legacy VFs after setting min_rate to at least one of the VFs did not disable QoS min_rate.</li>\n\t<li>An empty /usr/src/mlnx-ofa_kernel/default is now no longer created.</li>\n\t<li>An issue where installing packages through a repository failed after generation of metapackages using --add-kernel-support. The failure occurred due to excessive and incorrect Obsolete headers in those metapackages.Enabled installation of mlnx-ofa_kernel package to /bin/python3 instead of / usr/bin/python3 on RHEL 8.x systems.</li>\n\t<li>All IPoIB offload packets were wrongly counted as rx_csum_complete. These packets are now identified as rx_csum_unnecessary packets.</li>\n\t<li>mlx5dv_dr_rule_destroy segmentation fault could happen in rare cases with multiple rules on the same matcher with a different number of actions. This could happen after reusing an already deleted rule memory with less actions.</li>\n\t<li>An issue of moving to SwitchDev mode after configuring DSCP (Differentiated Service Code Point).</li>\n\t<li>Global traffic class configuration did not take effect on DC QPs (Dynamically Connected Queue Pairs).</li>\n\t<li>ib_send_bw traffic frequently dropped to zero when RDMA CM was used, because of incorrect&nbsp;min_rnr_timer setting on the responder side. The min_rnr_timer setting is now aligned with the setting in non-RDMA CM cases.</li>\n\t<li>Traffic did not pass over VFs with VST QinQ feature is enabled.</li>\n\t<li>When traffic was sent over Geneve VLAN with Tx VLAN offload enabled and TSO (TCP Segmentation Offload)&nbsp;or Tx csum enabled, traffic could be dropped and not sent to the wire.</li>\n\t<li>An issue that caused the firmware to restart upon installing mlnxofed-dpdk-upstream-libs package manually.</li>\n\t<li>Bad utility paths in rdma-core &quot;dracut&quot; hooks on SLES systems, which used to result in the following errors when running &quot;dracut&quot; with the &quot;--add rdma&quot; option. dracut-install:\n\t<ul>\n\t\t<li>ERROR: installing &lsquo;/usr/libexec/mlx4-setup.sh&rsquo; dracut: /usr/lib/dracut/dracut-install -D /var/tmp/dracut.UdCOSJ/ initramfs /usr/libexec/mlx4-setup.sh dracut-install: ERROR: installing &lsquo;/usr/libexec/rdma-set-sriov-vf&rsquo; dracut: /usr/lib/dracut/dracut-install -D /var/tmp/dracut.UdCOSJ/ initramfs /usr/libexec/rdma-set-sriov-vf</li>\n\t</ul>\n\t</li>\n\t<li>Traffic class value was not updated in DCT when set via sysfs.</li>\n\t<li>A doorbell loss issue on AMD platforms with Secure Memory Encryption (SME).</li>\n\t<li>Registering memory using mlx5dv_devx_umem_reg while forking. Without this fix, applications which use fork() or similar syscalls while using a memory registered with umem_reg could hang due to incorrect physical page mapping. This fix requires setting the IBV_FORK_SAFE environment variable.</li>\n\t<li>When&nbsp;unbinding the device resulted in the following message being printed to the dmesg: &quot;failed to disable DC tracer&quot;</li>\n\t<li>Content of file /sys/class/net//statistics/ multicast might have been out of date and might have displayed values lower than the real values.</li>\n\t<li>ERSPAN (Encapsulated Remote SPAN) protocol was available only when turning off Tx checksum offload.</li>\n\t<li>A udev script issue which caused non-mellanox devices to be renamed.</li>\n\t<li>Missing representor statistics when using ifconfig.</li>\n\t<li>Fixed wrong value of skb mark of received packets on representors.</li>\n\t<li>An issue which caused second port representors to be named as first port representors.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"kmod-mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager（SUM）と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5662320","datemodified":"2021-06-02T02:14:25","file_list":["SignedImageInstaller64.dll","U23_3.00_04_01_2021.signed.flash","cp047377.xml","cpqsetup.exe","cpqsysio64.sys"],"md5sum":"3b3e84c02b1928bdcb484094bb30842a","name":"cp047377.exe","release":"2021-06-02T01:57:22","revision":"0","sha1sum":"8ac26cc5e023e29369bf8e55b11a926e67ec22df","size":"5MB","target_guids":[],"type_of_change":"1","version":"3.00_04-01-2021"}],"id":{"product":"7a60cc43d9b440378249c6f65bfb67c0","version":"9a75223cb0f24efdacdaae8b07d1c041"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:&nbsp;</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the&nbsp;Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the&nbsp;Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the&nbsp;Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.&nbsp;</p>\n\n<p style=\"margin-left:0in; margin-right:0in\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p style=\"margin-left:0in; margin-right:0in\">Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。 </p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。 </p>\n\n<p style=\"margin-left:0in; margin-right:0in\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p style=\"margin-left:0in; margin-right:0in\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML30 Gen9 (U23) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant ML30 Gen9 (U23)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-26T07:14:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode: 0x000000E2 (CPUID 506E3). This Intel microcode patch provide mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-8696 and CVE-2020-8698. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00381. These issues are not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-24512. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-464. The Intel microcode patches included in this release are version 0x000000EA (CPUID 506E3 and CPUID 906E9). These issues are not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel sighting CVE-2020-24512. This security vulnerability is documented in Intel Security Advisory INTEL-SA-00463. The Intel microcode patches included in this release are version 0x000000EA (CPUID 506E3) and 0x000000EA (CPUID 906E9). This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-8670 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"}],"sw_keys":[{"name":"U23","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 adapter cards."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1378742","datemodified":"2021-07-21T07:44:40","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/rdma","./etc/rdma/mlx4.conf","./etc/rdma/modules","./etc/rdma/modules/rdma.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/70-persistent-ipoib.rules","./lib/udev/auxdev-sf-netdev-rename","./lib/udev/mlnx_bf_udev","./lib/udev/rules.d/82-net-setup-link.rules","./lib/udev/rules.d/83-mlnx-sf-name.rules","./lib/udev/rules.d/90-ib.rules","./lib/udev/sf-rep-netdev-rename","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/mlnx_bf_configure_ct","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_perf","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/include/mellanox/dpcp.h","./usr/lib/dracut","./usr/lib/dracut/modules.d","./usr/lib/dracut/modules.d/05rdma","./usr/lib/dracut/modules.d/05rdma/module-setup.sh","./usr/lib/mlx4-setup.sh","./usr/lib/modprobe.d","./usr/lib/modprobe.d/libmlx4.conf","./usr/lib/python2.7/site-packages/__pycache__/dcbnetlink.cpython-36.opt-1.pyc","./usr/lib/python2.7/site-packages/__pycache__/dcbnetlink.cpython-36.pyc","./usr/lib/python2.7/site-packages/__pycache__/genetlink.cpython-36.opt-1.pyc","./usr/lib/python2.7/site-packages/__pycache__/genetlink.cpython-36.pyc","./usr/lib/python2.7/site-packages/__pycache__/netlink.cpython-36.opt-1.pyc","./usr/lib/python2.7/site-packages/__pycache__/netlink.cpython-36.pyc","./usr/lib/python2.7/site-packages/dcbnetlink.py","./usr/lib/python2.7/site-packages/genetlink.py","./usr/lib/python2.7/site-packages/mlnx_tools-5.2.0-py3.6.egg-info","./usr/lib/python2.7/site-packages/netlink.py","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/rdma-ndd.service","./usr/lib/systemd/system/vma.service","./usr/lib/udev/rdma_rename","./usr/lib/udev/rules.d","./usr/lib/udev/rules.d/60-rdma-ndd.rules","./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules","./usr/lib/udev/rules.d/75-rdma-description.rules","./usr/lib/udev/rules.d/90-rdma-umad.rules","./usr/lib64/libdpcp.so","./usr/lib64/libdpcp.so.1","./usr/lib64/libdpcp.so.1.1.12","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.35.0","./usr/lib64/libibverbs","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.14.35.0","./usr/lib64/libibverbs/libmlx5-rdmav34.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.19.35.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.3.35.0","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.3.1","./usr/lib64/rsocket","./usr/lib64/rsocket/librspreload.so","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/ibdev2netdev","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/rdma-ndd","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vmad","./usr/share/doc/packages/dpcp","./usr/share/doc/packages/dpcp/README","./usr/share/doc/packages/libibverbs","./usr/share/doc/packages/libibverbs/libibverbs.md","./usr/share/doc/packages/librdmacm","./usr/share/doc/packages/librdmacm/librdmacm.md","./usr/share/doc/packages/libvma-9.3.1","./usr/share/doc/packages/libvma-9.3.1/CHANGES","./usr/share/doc/packages/libvma-9.3.1/README","./usr/share/doc/packages/mlnx-tools","./usr/share/doc/packages/mlnx-tools/ib2ib_setup.txt","./usr/share/doc/packages/rdma-core","./usr/share/doc/packages/rdma-core/COPYING.BSD_FB","./usr/share/doc/packages/rdma-core/COPYING.BSD_MIT","./usr/share/doc/packages/rdma-core/COPYING.GPL2","./usr/share/doc/packages/rdma-core/COPYING.md","./usr/share/doc/packages/rdma-core/README.md","./usr/share/doc/packages/rdma-core/tag_matching.md","./usr/share/doc/packages/rdma-core/udev.md","./usr/share/licenses/dpcp","./usr/share/licenses/dpcp/LICENSE","./usr/share/licenses/libvma","./usr/share/licenses/libvma/COPYING","./usr/share/man/man7/rsocket.7.gz","./usr/share/man/man7/vma.7.gz","./usr/share/man/man8/ib2ib_setup.8.gz","./usr/share/man/man8/rdma-ndd.8.gz","./usr/share/man/man8/vmad.8.gz","./usr/share/mlnx_ofed/mlnx_bf_assign_ct_cores.sh","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml"],"md5sum":"56aca53e47008ad189fd73b867ec5c31","name":"mlnx-ofa_kernel-5.4-OFED.5.4.1.0.3.1.sles15sp3.x86_64.rpm","release":"2021-07-21T06:07:06","revision":"0","sha1sum":"8616b0564da7639dba83a55488b47429b98a710f","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5"],"type_of_change":"1","version":"5.4"},{"bytes":"1679765","datemodified":"2021-07-21T07:47:26","file_list":["./lib/modules/5.3.18-57-default","./lib/modules/5.3.18-57-default/updates","./lib/modules/5.3.18-57-default/updates/compat","./lib/modules/5.3.18-57-default/updates/compat/mlx_compat.ko","./lib/modules/5.3.18-57-default/updates/drivers","./lib/modules/5.3.18-57-default/updates/drivers/base","./lib/modules/5.3.18-57-default/updates/drivers/base/auxiliary.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/core","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/core/ib_cm.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/core/ib_core.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/core/ib_ucm.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/core/ib_umad.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/core/iw_cm.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/core/rdma_cm.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/cxgb3","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/cxgb3/iw_cxgb3.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/cxgb4","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/efa","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/efa/efa.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/hfi1","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/i40iw","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/mlx4","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/mlx5","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/mthca","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/mthca/ib_mthca.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/ocrdma","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/ocrdma/ocrdma.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/qedr","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/qib","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/qib/ib_qib.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/usnic","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/sw","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/sw/rdmavt","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/sw/rxe","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/sw/siw","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/sw/siw/siw.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp/ipoib","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp/iser","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp/isert","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp/opa_vnic","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp/rtrs","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp/rtrs/rtrs-client.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp/rtrs/rtrs-core.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp/rtrs/rtrs-server.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp/srp","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp/srpt","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/5.3.18-57-default/updates/drivers/net","./lib/modules/5.3.18-57-default/updates/drivers/net/ethernet","./lib/modules/5.3.18-57-default/updates/drivers/net/ethernet/mellanox","./lib/modules/5.3.18-57-default/updates/drivers/net/ethernet/mellanox/mlx5","./lib/modules/5.3.18-57-default/updates/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/5.3.18-57-default/updates/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/5.3.18-57-default/updates/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/5.3.18-57-default/updates/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/5.3.18-57-default/updates/drivers/nvme","./lib/modules/5.3.18-57-default/updates/drivers/nvme/host","./lib/modules/5.3.18-57-default/updates/drivers/nvme/host/nvme-rdma.ko","./lib/modules/5.3.18-57-default/updates/drivers/nvme/target","./lib/modules/5.3.18-57-default/updates/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/5.3.18-57-default/updates/net","./lib/modules/5.3.18-57-default/updates/net/9p","./lib/modules/5.3.18-57-default/updates/net/9p/9pnet_rdma.ko","./lib/modules/5.3.18-57-default/updates/net/mlxdevm","./lib/modules/5.3.18-57-default/updates/net/mlxdevm/mlxdevm.ko","./lib/modules/5.3.18-57-default/updates/net/rds","./lib/modules/5.3.18-57-default/updates/net/rds/rds_rdma.ko","./lib/modules/5.3.18-57-default/updates/net/smc","./lib/modules/5.3.18-57-default/updates/net/smc/smc.ko","./lib/modules/5.3.18-57-default/updates/net/smc/smc_diag.ko","./lib/modules/5.3.18-57-default/updates/net/sunrpc","./lib/modules/5.3.18-57-default/updates/net/sunrpc/xprtrdma","./lib/modules/5.3.18-57-default/updates/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/5.3.18-57-default/updates/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/5.3.18-57-default/updates/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/mlnx-ofa_kernel-kmp-default/component.xml"],"md5sum":"536eb8eabcfc6e2610bed77ab6571667","name":"mlnx-ofa_kernel-kmp-default-5.4_k5.3.18_57-OFED.5.4.1.0.3.1.sles15sp3.x86_64.rpm","release":"2021-07-21T06:07:06","revision":"0","sha1sum":"f4bb16fabcb8dbde9c8004637731ba5feb392de7","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5"],"type_of_change":"1","version":"5.4"}],"id":{"product":"3c1cedac275a43ba93bd2bb1e94c8930","version":"a38500d79c964296a17ea852c80aef64"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"11.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPMs to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-5.4&quot; RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using 5.3.18-57-default&nbsp;kernel or any future errata:<br />\n<br />\n<strong># rpm -Uvh&nbsp;mlnx-ofa_kernel-5.4-OFED.5.4.0.5.1.1.sles15sp3.x86_64.rpm mlnx-ofa_kernel-kmp-default-5.4_k5.3.18_57-OFED.5.4.0.5.1.1.sles15sp3.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 Adapters for SUSE LINUX Enterprise Server 15 SP3 (AMD64/EM64T)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"101f","subdev":"0012","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30012","type":"pci","ven":"15b3"},{"dev":"101f","subdev":"0007","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30007","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"032D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-10171590032d","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T17:11:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>Changes and new features in HPE Mellanox RoCE driver&nbsp;version 5.3:</strong></p>\n\n<p><strong>For ConnectX-5 Adapters and above:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>CQE compression support for Rx multi-strides packets.</li>\n\t\t<li>Configuring QoS on a single QP or on a group of QPs.</li>\n\t\t<li>Encap/decap hardware offload of IPv4 traffic over MPLS-over-UDP. This can be used in networks with MPLS routers to achieve more efficient routing.</li>\n\t\t<li>Connection tracking rules on VFs to forward traffic from one VF to the other.</li>\n\t\t<li>Offloading sFlow sampling rules.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For ConnectX-5 Adapters and ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>A locking mechanism to enable parallel insertion of rules into the software steering using the mlx5dv_dr API. The parallel insertion improves the insertion rate and takes place when adding Rx and Tx rules via the FDB domain.</li>\n\t\t<li>Option to match mlx5dv_dr API on Geneve tunnel using a dynamic flex parser. The option header consists of class, type, length and data. The parser should be configured using devx command, after which a rule can be created to match on parser ID and data.</li>\n\t\t<li>Geneve tunneling offload, including matching on extension header.</li>\n\t\t<li>Parallel insertion and deletion of offloaded rules using multiple&nbsp;OVS threads.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>[Beta] Modify GTP-U TEID. This support requires flex parser&nbsp;configuration.</li>\n\t\t<li>[Beta] Improved performance of OVS Connection Tracking flows by&nbsp;enabling the merge of the multi-table flow matches and actions into one joint flow.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Dx Adapters and above:</strong></p>\n\n<p>Added support for the following features:</p>\n\n<ul>\n\t<li>Transmitted packet timestamping accuracy can be improved when using a timestamp generated at the port level instead of a timestamp generated upon CQE creation. Tx port time-stamping better reflects the actual time of a packet&#39;s transmission. This feature is disabled by default. The feature can be enabled or disabled using the following command. ethtool --set-priv-flags tx_port_ts on / off.</li>\n\t<li>Offloading tunnel rules when the source interface is VF (in addition to uplink) in the Hypervisor.</li>\n\t<li>Using Mirroring Offload with Connection Tracking.</li>\n\t<li>ASO flow meter using the mlx5dv_dr API, which allows for monitoring the packet rate for specific flows. When a packet hits a flow that is connected to a flow meter, the rate of packets through this meter is evaluated, and the packet is marked with a color copied into one of the C registers, according to the current rate compared to the reference rate.</li>\n\t<li>ASO first hit using the mlx5dv_dr API, which allows for tracking rule hits by packets. When a packet hits a rule with the ASO first hit action, a flag is set indicating this event, and the original value of the flag is copied to one of the C registers.</li>\n\t<li>mlx5dv_dr API support for matching on a new field &quot;gtpu_first_ext_dw_0&quot;. This field enables packet filtering based on the GTP-U first extension header (first dword only). To enable parsing of tunnel GTP-U extension header, run the following command. ./cloud_fw_reset.py FLEX_PARSER_PROFILE_ENABLE=3.</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Lx Adapters and above:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>IPsec full offload support for extended sequence number, replay protection window and lifetime packet limit.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;All HCA&#39;s:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>New query GID API that allows for querying a single GID entry by its port and GID index, or querying for all GID tables of a specific device. This API works over ioctl instead of sysfs, which accelerates the querying process.</li>\n\t\t<li>Performing multi-host firmware reset in order to upgrade the device firmware. Firmware reset loads the new firmware in case it was burnt on the flash and was pending activation, and reload.</li>\n\t\t<li>[Alpha] Firmware live patching in the driver. Live patching updates the firmware without the need to perform firmware reset. However, it can only be applied in scenarios where the difference between the current and new firmware versions are minor, which is decided upon by the firmware itself.</li>\n\t\t<li>devlink tool for performing firmware reset in order to upgrade the device firmware. Firmware reset loads the new firmware in case it was burnt on the flash and was pending activation, and reloads the current firmware image from the flash in case no new firmware was pending. For further information, please refer to the the devlink man page.</li>\n\t\t<li>A resiliency mechanism for the driver to manually poll the command event queue (EQ) in case of a command timeout. In case the resiliency mechanism finds unhandled event queue entry (EQE) due to a lost interrupt, the driver will handle it, after which the command interface returns to a healthy state.</li>\n\t\t<li>Setting a sniffer private flag is deprecated and no longer required. In order to capture offloaded/RoCE traffic, tcpdump can now be run on the RDMA device.</li>\n\t\t<li>Added per-port reporters to devlink health to manage per-port health activities. Users can now access the devlink port reporters by specifying the port index in addition to the device devlink name through the devlink health commands API. This update was first introduced in iproute2 v5.8. As part of this feature, mlx5e Tx and Rx reporters are now redefined as devlink port reporters. For examples, please see devlink-health manpage</li>\n\t\t<li>Optimized memory consumption of memory registration in huge page systems. As an example, in a 2MB huge page system, 600 MB would be saved for 100 GB memory registration.</li>\n\t\t<li>mlx5dv API to modify the configured UDP source port for RoCE packets of a given RC/UC QP when QP is in RTS state.</li>\n\t\t<li>Accelerating Tx datapath by saving PCI bandwidth and CPU utilization. The savings are achieved by aggregating multiple packets into a single WQE. The feature is driven by xmit_more for certain traffic types, such as UDP.</li>\n\t</ul>\n\t</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 5.3:</strong></p>\n\n<ul>\n\t<li>Clearing min_rate on all SR-IOV legacy VFs after setting min_rate to at least one of the VFs did not disable QoS min_rate.</li>\n\t<li>An empty /usr/src/mlnx-ofa_kernel/default is now no longer created.</li>\n\t<li>An issue where installing packages through a repository failed after generation of metapackages using --add-kernel-support. The failure occurred due to excessive and incorrect Obsolete headers in those metapackages.Enabled installation of mlnx-ofa_kernel package to /bin/python3 instead of / usr/bin/python3 on RHEL 8.x systems.</li>\n\t<li>All IPoIB offload packets were wrongly counted as rx_csum_complete. These packets are now identified as rx_csum_unnecessary packets.</li>\n\t<li>mlx5dv_dr_rule_destroy segmentation fault could happen in rare cases with multiple rules on the same matcher with a different number of actions. This could happen after reusing an already deleted rule memory with less actions.</li>\n\t<li>An issue of moving to SwitchDev mode after configuring DSCP (Differentiated Service Code Point).</li>\n\t<li>Global traffic class configuration did not take effect on DC QPs (Dynamically Connected Queue Pairs).</li>\n\t<li>ib_send_bw traffic frequently dropped to zero when RDMA CM was used, because of incorrect&nbsp;min_rnr_timer setting on the responder side. The min_rnr_timer setting is now aligned with the setting in non-RDMA CM cases.</li>\n\t<li>Traffic did not pass over VFs with VST QinQ feature is enabled.</li>\n\t<li>When traffic was sent over Geneve VLAN with Tx VLAN offload enabled and TSO (TCP Segmentation Offload)&nbsp;or Tx csum enabled, traffic could be dropped and not sent to the wire.</li>\n\t<li>An issue that caused the firmware to restart upon installing mlnxofed-dpdk-upstream-libs package manually.</li>\n\t<li>Bad utility paths in rdma-core &quot;dracut&quot; hooks on SLES systems, which used to result in the following errors when running &quot;dracut&quot; with the &quot;--add rdma&quot; option. dracut-install:\n\t<ul>\n\t\t<li>ERROR: installing &lsquo;/usr/libexec/mlx4-setup.sh&rsquo; dracut: /usr/lib/dracut/dracut-install -D /var/tmp/dracut.UdCOSJ/ initramfs /usr/libexec/mlx4-setup.sh dracut-install: ERROR: installing &lsquo;/usr/libexec/rdma-set-sriov-vf&rsquo; dracut: /usr/lib/dracut/dracut-install -D /var/tmp/dracut.UdCOSJ/ initramfs /usr/libexec/rdma-set-sriov-vf</li>\n\t</ul>\n\t</li>\n\t<li>Traffic class value was not updated in DCT when set via sysfs.</li>\n\t<li>A doorbell loss issue on AMD platforms with Secure Memory Encryption (SME).</li>\n\t<li>Registering memory using mlx5dv_devx_umem_reg while forking. Without this fix, applications which use fork() or similar syscalls while using a memory registered with umem_reg could hang due to incorrect physical page mapping. This fix requires setting the IBV_FORK_SAFE environment variable.</li>\n\t<li>When&nbsp;unbinding the device resulted in the following message being printed to the dmesg: &quot;failed to disable DC tracer&quot;</li>\n\t<li>Content of file /sys/class/net//statistics/ multicast might have been out of date and might have displayed values lower than the real values.</li>\n\t<li>ERSPAN (Encapsulated Remote SPAN) protocol was available only when turning off Tx checksum offload.</li>\n\t<li>A udev script issue which caused non-mellanox devices to be renamed.</li>\n\t<li>Missing representor statistics when using ifconfig.</li>\n\t<li>Fixed wrong value of skb mark of received packets on representors.</li>\n\t<li>An issue which caused second port representors to be named as first port representors.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWSXF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757535846","Version":"HPG3"},{"DeviceName":"VK000960GWSXH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757535848","Version":"HPG3"},{"DeviceName":"VK001920GWSXK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-30475753584b","Version":"HPG3"},{"DeviceName":"MK000480GWUGF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757554746","Version":"HPG3"},{"DeviceName":"MK000960GWUGH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757554748","Version":"HPG3"},{"DeviceName":"MK001920GWUGK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475755474b","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK000480GWSXF, VK000960GWSXH, VK001920GWSXK, MK000480GWUGF, MK000960GWUGH, MK001920GWUGK Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VK000480GWSXF、VK000960GWSXH、VK001920GWSXK、MK000480GWUGF、MK000960GWUGH、MK001920GWUGKドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;VK000480GWSXF, VK000960GWSXH, VK001920GWSXK, MK000480GWUGF, MK000960GWUGH and&nbsp;MK001920GWUGK&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5012884","datemodified":"2021-07-23T08:54:09","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG3-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG3-2.1/CP048189.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG3-2.1/M5200SG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG3-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048189.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048189.scexe"],"md5sum":"f68fc6e11f9a38abb267e09d7c26e347","name":"firmware-hdd-9e87eecb3f-HPG3-2.1.x86_64.rpm","release":"2021-07-23T08:41:11","revision":"0","sha1sum":"dc24b051cb048c7c9fa245a79d039c8d7b4a7a34","size":"4MB","target_guids":["562340a5-304b-3030-3438-304757535846","562340a5-304b-3030-3936-304757535848","562340a5-304b-3130-3932-30475753584b","4d2340a5-304b-3030-3438-304757554746","4d2340a5-304b-3030-3936-304757554748","4d2340a5-304b-3130-3932-30475755474b"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"4cc24985bf9c485084dcadb54a29cb28","version":"e36ff6da611841979a34a23a103548fb"},"installation":{"command":"CP040781.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/jp/servers/spp_dl\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK000480GWSXF, VK000960GWSXH, VK001920GWSXK, MK000480GWUGF, MK000960GWUGH and MK001920GWUGK Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VK000480GWSXF、VK000960GWSXH、VK001920GWSXK、MK000480GWUGF、MK000960GWUGH、MK001920GWUGKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VK001920GWSXK","target_guid":"562340a5-304b-3130-3932-30475753584b","type":"sata"},{"id":"MK001920GWUGK","target_guid":"4d2340a5-304b-3130-3932-30475755474b","type":"sata"},{"id":"VK000960GWSXH","target_guid":"562340a5-304b-3030-3936-304757535848","type":"sata"},{"id":"MK000960GWUGH","target_guid":"4d2340a5-304b-3030-3936-304757554748","type":"sata"},{"id":"VK000480GWSXF","target_guid":"562340a5-304b-3030-3438-304757535846","type":"sata"},{"id":"MK000480GWUGF","target_guid":"4d2340a5-304b-3030-3438-304757554746","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T09:09:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Improved Product Quality and Reliability. Changed Cap Charge Timeout to 14 seconds from 4 seconds to provide additional time for cap charge in marginal power environment.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK000480GWUGF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK001920GWUGK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWUGH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWSXF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GWSXK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWSXH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ed1590020e","Version":"218.0.166000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ec1590020e","Version":"218.0.166000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d71590020e","Version":"218.0.166000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ed15900211","Version":"218.0.166000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ec15900211","Version":"218.0.166000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d715900211","Version":"218.0.166000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ed159002c5","Version":"218.0.166000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ec159002c5","Version":"218.0.166000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d7159002c5","Version":"218.0.166000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ed159002c3","Version":"218.0.166000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ec159002c3","Version":"218.0.166000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d7159002c3","Version":"218.0.166000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16eb15900230","Version":"218.0.166000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16de15900230","Version":"218.0.166000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d615900230","Version":"218.0.166000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ef1590020c","Version":"218.0.166000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ee1590020c","Version":"218.0.166000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d81590020c","Version":"218.0.166000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ef15900212","Version":"218.0.166000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ee15900212","Version":"218.0.166000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d815900212","Version":"218.0.166000"}]},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E Gigabit Ethernet NIC firmware."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains NVM Image version 218.0.166000 with the following firmware versions:</p>\n\n<ul>\n\t<li>Bootcode Version: 218.0.152.0</li>\n\t<li>NCSI Version: 218.0.125.0</li>\n\t<li>MBA Version:&nbsp;218.0.29.0</li>\n\t<li>UEFI Version:&nbsp;218.0.64.0</li>\n\t<li>CCM Version:&nbsp;218.0.19.0</li>\n\t<li>RoCE Version:&nbsp;218.0.5.0</li>\n</ul>\n"}],"files":[{"bytes":"8060474","datemodified":"2021-02-09T07:29:38","file_list":["bcm218.0.166000.Optimized.pup.HPb","bcm218.0.166000.Optimized.pup.xml","payload.json"],"md5sum":"c5136fcb6f46a0208bf5a5378681f077","name":"bcm218.0.166000.Optimized.pup.fwpkg","release":"2021-02-09T07:25:10","revision":"0","sha1sum":"0134d3a6b5ee6ae15d1af68dc8e0124caaa959a9","size":"7MB","target_guids":["a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16eb15900230","a6b1a447-382a-5a4f-14e4-16de15900230","a6b1a447-382a-5a4f-14e4-16d615900230","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16d815900212"],"type_of_change":"1","version":"218.0.166000"}],"id":{"product":"8d2bd99747b540d2a364efef8e58a91c","version":"523b8eb282404350b8cb2426c220088c"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p>\n\n<ol style=\"list-style-type:decimal\">\n\t<li>Flash using iLOrest tool&nbsp;</li>\n\t<li>Flash using&nbsp;Smart Update Manager (SUM).</li>\n\t<li>Flash from iLO GUI</li>\n</ol>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the PLDM supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>\n\t<li>Reboot the server for the firmware update to take effect.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E Firmware Package for BCM5741x adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial version</p>\n","curr_fixes_x_late":"<ul>\n\t<li>This product addresses a modification on help string of Family Firmware Version.</li>\n\t<li>This product addresses an enhancement on LLDP functional option naming under RBSU and the interactivity of DCB protocol option.</li>\n\t<li>This product addresses an issue about lack of MAC address while querying via RedFish.</li>\n\t<li>This product addresses an issue about failing to recognize the adapter firmware version under Microsoft Windows(R).</li>\n\t<li>This product addresses an issue for receiving PCIe errors while installing SUSE Linux Enterprise Server.</li>\n\t<li>This product addresses an issue for packets missing when UDP multicast application is started/stopped.</li>\n\t<li>This product addresses an issue for HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter not linking up during POST.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"NIC_NXE_PKG","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900213","languages":[{"lang":"fr","x_late":"Micrologiciel - Lights-Out Management"},{"lang":"en","x_late":"Firmware - Lights-Out Management"},{"lang":"cn","x_late":"固件 - Lights-Out Management"},{"lang":"tw","x_late":"韌體 ─ Lights─Out 管理"},{"lang":"de","x_late":"Firmware - LOM (Lights-Out Management)"},{"lang":"ko","x_late":"펌웨어 - Lights-Out 관리"},{"lang":"ja","x_late":"ファームウェア - Lights-Outマネジメント"},{"lang":"es","x_late":"Firmware - Administración de apagado eléctrico"}]}],"description":[{"lang":"en","x_late":"This component provides updated iLO firmware that can be installed directly on supported Linux Operating Systems. Use this component with HPE Smart Update Manager to update supported HPE ProLiant Gen8 and Gen9, HPE Apollo Gen9, and HPE Synergy 480 Gen9 systems. Click the “Installation Instructions” tab to review important firmware update details."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるLinuxオペレーティングシステムに直接インストール可能なアップデートされたiLOファームウェアを提供します。このコンポーネントをHPE Smart Update Managerとともに使用して、サポートされているHPE ProLiant Gen8およびGen9、HPE Apollo Gen9、およびHPE Synergy 480 Gen9システムをアップデートします。[インストール手順]タブをクリックして、重要なファームウェアアップデートの詳細を確認します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[{"lang":"en","x_late":"<p>&nbsp;</p>\n\n<p>iLO&nbsp;4 User Guide and Lights-Out Scripting Guide can also be found by following the links at:<br />\n<br />\n<a href=\"http://www.hpe.com/info/ilo\">http://www.hpe.com/info/ilo</a><br />\n<br />\nSelect your lights-out product, then support &amp; documents, then manuals.<br />\n&nbsp;</p>\n\n<ul>\n\t<li>Check the online help for additional information about how to use features.&nbsp;<br />\n\tOnline help can be accessed from within the browser web pages by clicking the question mark in the upper right-hand corner of each page.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p> </p>\n\n<p>iLO 4ユーザーガイドおよびLights-Outスクリプティングガイドは、以下のリンクから入手可能です。<br />\n<br />\n<a href=\"http://www.hpe.com/info/ilo\">http://www.hpe.com/info/ilo</a><br />\n<br />\nご使用のLights-Out製品、サポートドキュメント、ドキュメントの順に選択します。<br />\n </p>\n\n<ul>\n\t<li>この機能の使用方法について詳しくは、オンラインヘルプを参照してください。 <br />\n\tオンラインヘルプは、各ページの右上隅のクエスチョンマークをクリックすると、ブラウザーからアクセスできます。</li>\n</ul>\n"}],"files":[{"bytes":"14128410","datemodified":"2021-04-28T16:02:48","file_list":["./usr/lib/i386-linux-gnu/firmware-ilo4-2.78-1.1","./usr/lib/i386-linux-gnu/firmware-ilo4-2.78-1.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-ilo4-2.78-1.1/.setup","./usr/lib/i386-linux-gnu/firmware-ilo4-2.78-1.1/CP046465.xml","./usr/lib/i386-linux-gnu/firmware-ilo4-2.78-1.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-ilo4-2.78-1.1/ilo4_278.bin","./usr/lib/i386-linux-gnu/firmware-ilo4-2.78-1.1/readme.txt","./usr/lib/i386-linux-gnu/firmware-ilo4-2.78-1.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP046465.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP046465.scexe"],"md5sum":"d9d6bccba6307a623596aa4d44415431","name":"firmware-ilo4-2.78-1.1.i386.rpm","release":"2021-05-07T00:00:00","revision":"1","sha1sum":"c99f1071ea8ea2e6184450719ab193e8edd9c7a5","size":"13MB","target_guids":[],"type_of_change":"2","version":"2.78"}],"id":{"product":"d8701885e8a84180a8d83022fac7f1e4","version":"0b088e08ac7e45b7b04ff0ef9af2329a"},"installation":{"command":"sh CP0XXXXX.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 3/4 Channel Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 3/4 Channel Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"}]},{"ListConditional":"OR","Requirement":[]}]}]},"installation_notes":[{"lang":"en","x_late":"<h2><strong>For supported HPE Synergy 480 Gen9 Systems:</strong></h2>\n\n<p>This firmware release is fully supported when applied as a hotfix to the following HPE Synergy Software Releases:&nbsp;</p>\n\n<ul>\n\t<li>All HPE OneView versions 5.4&nbsp;and later in combination with HPE Synergy Custom SPP 2020.07, and HPE Synergy Custom SPP 2021.01</li>\n\t<li>All HPE OneView versions 5.6 and later in combination with HPE Synergy Custom SPP 2021.02</li>\n</ul>\n\n<p>For Synergy Hotfix installation instructions see HPE iLO User guide [https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=c03334051] sections titled:&nbsp;</p>\n\n<ul>\n\t<li>Adding hotfixes to create an HPE OneView custom firmware bundle</li>\n\t<li>Using HPE Smart Update Manager to create a custom ISO on Windows</li>\n</ul>\n\n<h2><strong>For supported HPE ProLiant Gen8, ProLiant Gen9, Apollo 4200 Gen9, and Apollo 4350 Gen9 Systems: </strong></h2>\n\n<p><strong>To update firmware from the Linux operating system on target server:</strong></p>\n\n<ul>\n\t<li>Download the SCEXE file to the target server.</li>\n\t<li>Execute: sh CP0xxxxx.scexe</li>\n</ul>\n\n<p><strong>To obtain firmware image for updating via iLO user interface, utilities, or scripting interface:</strong></p>\n\n<ul>\n\t<li>Download the SCEXE file to a client running&nbsp;a Linux operating system.&nbsp; Execute: sh&nbsp; CP0xxxxx.scexe&nbsp;--unpack=directory</li>\n\t<li>This command will unpack the ilo4_1XX.bin into a user specified &quot;directory&quot;. If the directory does not exist, the unpacker will attempt to create it.</li>\n</ul>\n\n<p><strong>To use HPE Smart Update Manager on the Firmware Maintenance CD</strong><strong>:</strong></p>\n\n<ul>\n\t<li>Place the Firmware Maintenance CD on a USB key using the HPE USB Key Creator Utility.&nbsp;</li>\n\t<li>Copy&nbsp; CP0xxxxx.scexe&nbsp;to /compaq/swpackages directory on the USB Key.</li>\n\t<li>Follow HPE Smart Update Manager steps to complete firmware update.</li>\n</ul>\n"},{"lang":"ja","x_late":"<h2><strong>サポートされているHPE Synergy 480 Gen9システムの場合：</strong></h2>\n\n<p>このファームウェアリリースは、次のHPE Synergyソフトウェアリリースのホットフィックスとして適用されると完全にサポートされます。 </p>\n\n<ul>\n\t<li>HPE OneViewバージョン5.4以降のすべてと、HPE SynergyカスタムSPP 2020.07およびHPE SynergyカスタムSPP 2021.01の組み合わせ</li>\n\t<li>HPE OneViewバージョン5.6以降のすべてと、HPE SynergyカスタムSPP 2021.02の組み合わせ</li>\n</ul>\n\n<p>Synergyホットフィックスのインストール手順については、HPE iLOユーザーガイド[https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&docId=c03334051]で次のタイトルのセクションを参照してください。 </p>\n\n<ul>\n\t<li>Adding hotfixes to create an HPE OneView custom firmware bundle</li>\n\t<li>Using HPE Smart Update Manager to create a custom ISO on Windows</li>\n</ul>\n\n<h2><strong>サポートされているHPE ProLiant Gen8、ProLiant Gen9、Apollo 4200 Gen9、およびApollo 4350 Gen9システムの場合：</strong></h2>\n\n<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>SCEXEファイルをターゲットサーバーにダウンロードします。</li>\n\t<li>Execute: sh CP0xxxxx.scexe</li>\n</ul>\n\n<p><strong>iLOユーザーインターフェイス、ユーティリティ、またはスクリプティングインターフェイス経由でアップデートするためのファームウェアイメージを取得するには:</strong></p>\n\n<ul>\n\t<li>Linuxオペレーティングシステムを実行しているクライアントにSCEXEファイルをダウンロードします。  Execute: sh  CP0xxxxx.scexe --unpack=directory</li>\n\t<li>このコマンドにより、ユーザーの指定した「ディレクトリ」にilo4_1XX.binが解凍されます。ディレクトリが存在しない場合、unpackerはそのディレクトリを作成しようとします。</li>\n</ul>\n\n<p><strong>Firmware Maintenance CDのHPE Smart Update Managerを使用するには</strong><strong>：</strong></p>\n\n<ul>\n\t<li>HPE USB Key Utilityを使用して、Firmware Maintenance CDをUSBキーに格納します。 </li>\n\t<li>CP0xxxxx.scexeをUSBキーの/compaq/swpackagesディレクトリにコピーします。</li>\n\t<li>HPE Smart Update Managerの手順に従って、ファームウェアのアップデートを完了します。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE Integrated Lights-Out 4"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE Integrated Lights-Out 4"}],"prerequisites":{"required_diskspace":{"size_kb":"5120"},"supported_devices":[{"id":"5219994","target_guid":"","type":"other"},{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3308","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3300","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3301","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3302","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86)","platform":"red_hat_enterprise_linux_x86","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Workstation (x86)","platform":"red_hat_enterprise_linux_client_x86","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Workstation (x86-64)","platform":"red_hat_enterprise_linux_client_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (x86)","platform":"suse_linux_enterprise_server_x86","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T12:36:36","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>&nbsp;-&nbsp; Updated Jquery library to 3.5.1<br />\n&nbsp;-&nbsp; Updated Openssl library to OpenSSL 1.0.2x<br />\n&nbsp;-&nbsp; eRS enhanced to support generic service event 1000 for critical events<br />\n&nbsp;</p>\n","latest_fixes_x_late":"<p>- IML reports fan modules failed for D3000 only after server reboot<br />\n&nbsp;&nbsp; &nbsp;- eRS service event added for Critical events like System Power Fault Detection<br />\n&nbsp;&nbsp; &nbsp;- Security fixes<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; - Added a Content Security Policy( CSP) to harden the web interfaces<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; - Enhanced Input validation for user controlled data</p>\n\n<p>- Fixes for multiple security vulnerabilities</p>\n"},{"curr_enhancements_x_late":"<p>&nbsp;-&nbsp; Updated Jquery library to 3.5.1<br />\n&nbsp;-&nbsp; Updated Openssl library to OpenSSL 1.0.2x<br />\n&nbsp;-&nbsp; eRS enhanced to support generic service event 1000 for critical events<br />\n&nbsp;</p>\n","curr_fixes_x_late":"<p>- IML reports fan modules failed for D3000 only after server reboot<br />\n&nbsp;&nbsp; &nbsp;- eRS service event added for Critical events like System Power Fault Detection<br />\n&nbsp;&nbsp; &nbsp;- Security fixes<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; - Added a Content Security Policy( CSP) to harden the web interfaces<br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; - Enhanced Input validation for user controlled data</p>\n\n<p>- Fixes for multiple security vulnerabilities</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"P94","value":"HP ProLiant XL220a Gen8 v2 Server"},{"key":"J06","value":"HP ProLiant MicroServer Gen8"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P74","value":"HP ProLiant SL140s Gen8 Server (private)"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P98","value":"HP ProLiant SL220f Gen8 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"Carbondale14","value":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A29","value":"HP ProLiant DL585 Gen8 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 SE Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P78","value":"HP ProLiant ML310e Gen8 v2 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"P83","value":"HP ProLiant SL210t Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P94","value":"HP ProLiant SL241n Gen8 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"P91","value":"HP ProLiant SL240n Gen8 Server - cancelled"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P93","value":"HP ProLiant SL240d Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 SE Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"}],"sw_keys":[{"name":"RI10","sw_key_expectedpath":"firmware:ilo4"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.82.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C339D","Version":"7.18.82"},{"DeviceName":"HPE Ethernet 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.82.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C18D3","Version":"7.18.82"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.82.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C1930","Version":"7.18.82"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.82.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C193A","Version":"7.18.82"},{"DeviceName":"HPE FlexFabric 10Gb 4-port 536FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.82.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-16A1159000EC","Version":"7.18.82"},{"DeviceName":"HPE NPAR 10Gb QP 536FLR-T","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.82.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-16A4159000EC","Version":"7.18.82"},{"DeviceName":"HPE StoreFabric CN1100R 10GBASE-T Dual Port Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.82.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E15908148","Version":"7.18.82"},{"DeviceName":"HPE StoreFabric CN1100R Dual Port Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.82.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C1931","Version":"7.18.82"},{"DeviceName":"HP NPAR 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.82.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C339D","Version":"7.18.82"},{"DeviceName":"HP NPAR 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.82.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C18D3","Version":"7.18.82"},{"DeviceName":"HP NPAR 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.82.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C193A","Version":"7.18.82"},{"DeviceName":"HP NPAR 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.82.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C1930","Version":"7.18.82"},{"DeviceName":"HP NPAR CN1100R Dual Port Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.82.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C1931","Version":"7.18.82"},{"DeviceName":"HPE NPAR 10Gb DP CN1100R-T","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.82.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE15908148","Version":"7.18.82"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic NX2 Gigabit Ethernet NICs Boot code, PXE, NCSI, iSCSI, FCoE and CCM code running under Microsoft Windows Server 2012 R2, Windows Server 2016 and Windows Server 2019."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"4083216","datemodified":"2021-08-12T11:00:22","file_list":["cp046936.xml","cpqsetup.exe","FW/","FW/firmware.json","FW/hp_mbi_7.18.82.bin","ja/","ja/NICOFUT.chm","LibQLGC_HpFwUpg.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","QLMAPIa.dll","QLNICFWUpg.exe","tcl83.dll","zh-CN/","zh-CN/NICOFUT.chm"],"md5sum":"ebd0294dc2570211a98c9ca0493ce998","name":"cp046936.exe","release":"2021-08-12T10:53:06","revision":"0","sha1sum":"fb917bfaa5c365b429cd476717397ebf67bbcec6","size":"3MB","target_guids":["a6b1a447-382a-5a4f-14E4-168E103C339D","a6b1a447-382a-5a4f-14E4-168E103C18D3","a6b1a447-382a-5a4f-14E4-168E103C1930","a6b1a447-382a-5a4f-14E4-168E103C193A","a6b1a447-382a-5a4f-1077-16A1159000EC","a6b1a447-382a-5a4f-1077-16A4159000EC","a6b1a447-382a-5a4f-14E4-168E15908148","a6b1a447-382a-5a4f-14E4-168E103C1931","a6b1a447-382a-5a4f-14E4-16AE103C339D","a6b1a447-382a-5a4f-14E4-16AE103C18D3","a6b1a447-382a-5a4f-14E4-16AE103C193A","a6b1a447-382a-5a4f-14E4-16AE103C1930","a6b1a447-382a-5a4f-14E4-16AE103C1931","a6b1a447-382a-5a4f-14E4-16AE15908148"],"type_of_change":"1","version":"5.2.5.0"}],"id":{"product":"1e10e20d274448bb9d2d1625880b482d","version":"55d735f7885a4bd39e8594ba18501c12"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic NX2 10/20 GbE Multifunction Driver version 7.13.165.0 or greater is required and should be already active","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec9bc6b74c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.13.165.0","description":"HPE QLogic NX2 10/20 GbE Multifunction Driver version 7.13.165.0 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation.</p>\n\n<p>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</p>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic NX2 Online Firmware Upgrade Utility for Windows Server x64 Editions"},{"lang":"ja","x_late":"HPE QLogic NX2オンラインファームウェアアップグレードユーティリティ for Windows Server x64 Edition"}],"prerequisites":{"required_diskspace":{"size_kb":"5400"},"supported_devices":[{"dev":"168E","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c339d","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c18d3","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1930","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c193a","type":"pci","ven":"14E4"},{"dev":"16A1","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a1159000ec","type":"pci","ven":"1077"},{"dev":"16A4","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a4159000ec","type":"pci","ven":"1077"},{"dev":"168E","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-168e15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1931","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c339d","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c193a","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1930","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1931","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ae15908148","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li><strong>This product addressed the firmware update failure problem which may cause NIC FW corruption.</strong></li>\n\t<li><strong>This product addressed the firmware update failure problem while the platform secure boot being enabled.</strong></li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>This product now supports Microsoft Windows Server 2022.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"QlNicFwUpg.exe","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWWQP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNESD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57575150","Version":"HPD6"},{"DeviceName":"MB006000JWWQN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNESD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a5757514e","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB008000JWWQP and MB006000JWWQN Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB008000JWWQPおよびMB006000JWWQNドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB008000JWWQP and MB006000JWWQN Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD2</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5913115","datemodified":"2021-07-23T09:16:08","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD6-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD6-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD6-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD6-2.1/CP048200.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD6-2.1/SCIMARRNESD6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD6-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD6-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD6-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD6-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048200.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048200.scexe"],"md5sum":"c3e6fbe9b2df49b2a6f169d791d753aa","name":"firmware-hdd-ae6b41e855-HPD6-2.1.x86_64.rpm","release":"2021-07-23T09:04:11","revision":"0","sha1sum":"bccb01c532789c3e9e2eed7183d52e586db85287","size":"5MB","target_guids":["4d2340a5-3042-3830-3030-304a57575150","4d2340a5-3042-3630-3030-304a5757514e"],"type_of_change":"1","version":"HPD6"}],"id":{"product":"f66d2f40fe3b49a2ae22ce155e429f5c","version":"60a417fc8d944f3d9919c79396792746"},"installation":{"command":"CP043258.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB008000JWWQP and MB006000JWWQN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for Linux (x64) - MB008000JWWQPおよびMB006000JWWQNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB006000JWWQN","target_guid":"4d2340a5-3042-3630-3030-304a5757514e","type":"sas"},{"id":"MB008000JWWQP","target_guid":"4d2340a5-3042-3830-3030-304a57575150","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T11:10:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000JWWQP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB006000JWWQN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE ProLiant Smart Array Px4x and Hx4x series controllers. This RPM provides a customer friendly approach to install a pre-built binary driver.\nOn some kernel erratas the version of the driver present in the kernel may be equal to the version being installed by the rpm.  However, the driver in the kernel may not include all of the fixes and enhancements implemented in the driver contained within the rpm.  Therefore the rpm should be installed in order to obtain the fixes and enhancements that are not present in the kernel driver."},{"lang":"ja","x_late":"このRPMは、HPE ProLiant SmartアレイPx4xおよびHx4xシリーズコントローラーを有効にするためのプレビルドバイナリドライバーモジュールを提供します。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。errataカーネルによっては、カーネル内に存在するドライバーのバージョンとrpmによってインストールされたバージョンが等しい場合があります。だたし、カーネル内のドライバーは、rpmに含まれるドライバーに対して行われた、すべての修正と拡張が含まれていないことがあります。そのため、rpmはカーネルドライバーに存在しない、修正と拡張を入手するため、インストールする必要があります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"78363","datemodified":"2021-06-08T10:37:21","file_list":["./etc/depmod.d/hpsa.conf","./lib/modules/4.18.0-305.el8.x86_64","./lib/modules/4.18.0-305.el8.x86_64/extra","./lib/modules/4.18.0-305.el8.x86_64/extra/hpsa","./lib/modules/4.18.0-305.el8.x86_64/extra/hpsa/hpsa.ko","./usr/lib/.build-id","./usr/lib/.build-id/2e","./usr/lib/.build-id/2e/dfe204657f9e84d4a5715f3693f8be622c3a0d","./usr/share/smartupdate/kmod-hpsa/component.xml"],"md5sum":"bfbec80541ac894d3fe25bf5726ff74b","name":"kmod-hpsa-3.4.20-208.rhel8u4.x86_64.rpm","release":"2021-06-08T10:25:10","revision":"0","sha1sum":"7671170b214fa1580327da1aaac1b6c71362062b","size":"76KB","target_guids":[],"type_of_change":"1","version":"3.4.20-208"},{"bytes":"77736","datemodified":"2021-06-08T10:43:06","file_list":["./etc/depmod.d/hpsa.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/hpsa","./lib/modules/4.18.0-240.el8.x86_64/extra/hpsa/hpsa.ko","./usr/lib/.build-id","./usr/lib/.build-id/d7","./usr/lib/.build-id/d7/7073631bdfedfd3bc307d9e3ffcbf7dea9bf98","./usr/share/smartupdate/kmod-hpsa/component.xml"],"md5sum":"ff93d54fd9e5e92f92a9d5e29a50c961","name":"kmod-hpsa-3.4.20-208.rhel8u3.x86_64.rpm","release":"2021-06-08T10:25:10","revision":"0","sha1sum":"a7992d18a8dbe0b51efddeb0762736d6f0556167","size":"75KB","target_guids":[],"type_of_change":"1","version":"3.4.20-208"}],"id":{"product":"4f66ba55022c4d27b6cbd8baecfe7d6d","version":"845e9f29d4b84a7f873cd0d7f74d1d71"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as the system administrator (root), download the RPM to a directory on<br />\nyour hard drive and change to that directory.</p>\n\n<p><strong>To install or upgrade&nbsp;the driver type:</strong></p>\n\n<ul>\n\t<li># rpm -Uvh kmod-hpsa-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm&nbsp;&nbsp;</li>\n</ul>\n\n<p style=\"margin-right:0px\">Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p><strong>NOTE</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:</p>\n\n<ul>\n\t<li># rpm -e kmod-hpsa-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong><u>Enterprise Support</u></strong><br />\nFor support on Smart Array controllers, visit <a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a></p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>システム管理者（root）としてログインし、RPMを<br />\nご使用のハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</p>\n\n<p><strong>ドライバーをインストールまたはアップグレードするには次のようにタイプします。</strong></p>\n\n<ul>\n\t<li># rpm -Uvh kmod-hpsa-<version>.<OSupdate>.x86_64.rpm  </li>\n</ul>\n\n<p style=\"margin-right:0px\">Setup is now complete. コンピューターをただちに再起動してください。</p>\n\n<p><strong>注記</strong>：インストールの失敗、あるいは警告やエラーメッセージを表示して停止した場合は、コンピューターを再起動しないでください。ドライバーは動作しないため、以下のコマンドをタイプしてアンインストールしてください。</p>\n\n<ul>\n\t<li># rpm -e kmod-hpsa-<version>.<OSupdate>.x86_64.rpm</li>\n</ul>\n\n<p> </p>\n\n<p><strong><u>エンタープライズサポート</u></strong><br />\nSmartアレイコントローラーのサポートに関しては、<a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a>を参照してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE ProLiant Smart Array Controller (64-bit) Driver for Red Hat Enterprise Linux 8 (64-bit)"},{"lang":"ja","x_late":"Red Hat Enterprise Linux 8（64-bit）用HPE ProLiant Smartアレイコントローラー（64-bit）ドライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"323c","subdev":"1928","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21BD","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ca","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1922","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1923","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c2","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c0","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c3","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1926","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21be","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3353","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1924","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1921","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cb","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c1","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c5","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21CD","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cc","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3355","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3350","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3351","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3354","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3352","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323B","subdev":"3356","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3239","subdev":"21c7","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21bf","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c8","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c6","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ce","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-06T09:49:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support for Red Hat Enterprise Linux 8.3</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added support for Red Hat Enterprise Linux 8.4</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P74","value":"HP ProLiant SL140s Gen8 Server (private)"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 v2 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"P83","value":"HP ProLiant SL210t Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I14","value":"HP ProLiant BL480c Server"}],"sw_keys":[{"name":"kmod-hpsa","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hpsa","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hpsa","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hpsa","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5930832","datemodified":"2021-05-18T01:28:25","file_list":["SignedImageInstaller64.dll","U14_2.90_04_29_2021.signed.flash","cp047890.xml","cpqsetup.exe","cpqsysio64.sys"],"md5sum":"c66af61408dd0665fad36d111da26f81","name":"cp047890.exe","release":"2021-05-18T01:12:06","revision":"0","sha1sum":"dd25a7ae073af1b04c2fb071fa6b90e7ffc661b4","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021"}],"id":{"product":"393089474d234baf8404a8ee98140881","version":"81b28cd0429849c0aaae5d23d873ae98"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant XL170r/XL190r Gen9 (U14) Servers "},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant XL170r/XL190r Gen9（U14）サーバー "}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-06T15:44:46","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","latest_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358.  These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390.  These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"U14","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWTHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757544841","Version":"HPG3"},{"DeviceName":"VK000960GWTHB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757544842","Version":"HPG3"},{"DeviceName":"VK001920GWTHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757544843","Version":"HPG3"},{"DeviceName":"VK003840GWTHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304757544844","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp; &nbsp;</strong> HPG2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; &nbsp;None</p>\n"}],"files":[{"bytes":"17924722","datemodified":"2021-08-30T06:14:21","file_list":["/CP049275_BUILD_1.data","/CP049275.vmexe","/CP049275.vmexe64","/CP049275.vmfile","/CP049275_VMw.zip","/CP049275.xml","/payload.json","/CP049275_VMw.zip/index.xml","/CP049275_VMw.zip/vendor-index.xml","/CP049275_VMw.zip/metadata.zip","/CP049275_VMw.zip/vib20/CP049275/HPE_bootbank_CP049275_HPG3.1-7.0.0.15843807.vib","/CP049275_VMw.zip/metadata.zip/vendor-index.xml","/CP049275_VMw.zip/metadata.zip/vmware.xml","/CP049275_VMw.zip/metadata.zip/vibs/CP049275--3623784505556664958.xml","/CP049275_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049275_HPG3.1-7.0.0.15843807.xml"],"md5sum":"d7936ebf2a112a03b251503cdb72d87a","name":"CP049275.zip","release":"2021-08-30T06:08:56","revision":"0","sha1sum":"740926c55af74b15731be4c7dcef7304a6827def","size":"17MB","target_guids":["562340a5-304b-3030-3438-304757544841","562340a5-304b-3030-3936-304757544842","562340a5-304b-3130-3932-304757544843","562340a5-304b-3330-3834-304757544844"],"type_of_change":"1","version":"HPG3","vib_list":[{"name":"CP049275","version":"HPG3.1-7.0.0.15843807"}]}],"id":{"product":"a4fb8dc02faf478a85519ccf77530c6a","version":"ee8fccebdbac467789857df927f96d69"},"installation":{"command":"CP041496.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD  Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi -VK000480GWTHA、VK000960GWTHB、VK001920GWTHCおよびVK003840GWTHDドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VK003840GWTHD","target_guid":"562340a5-304b-3330-3834-304757544844","type":"sata"},{"id":"VK001920GWTHC","target_guid":"562340a5-304b-3130-3932-304757544843","type":"sata"},{"id":"VK000960GWTHB","target_guid":"562340a5-304b-3030-3936-304757544842","type":"sata"},{"id":"VK000480GWTHA","target_guid":"562340a5-304b-3030-3438-304757544841","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-13T14:17:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This maintenance FW release addresses a rare corner case COMRESET issue at warm boot, and to address an early EOL behavior under certain use cases.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK001920GWTHC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GWTHD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWTHA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWTHB","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the iSCSI driver for the HPE Emulex 10/20Gb Server Adapters for Windows Server 2016."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Windows Server 2016用のHPE Emulex 10/20GbサーバーアダプターのiSCSIドライバー を含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"907296","datemodified":"2020-06-12T06:47:06","file_list":["be2iscsi.cat","be2iscsi.inf","be2iscsi.sys","bepiscsi.dll","cp044561.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"md5sum":"d7398cbac6a655eb182f2b86ba3d8494","name":"cp044561.exe","release":"2020-06-12T06:33:15","revision":"0","sha1sum":"93c0e7dbdda6b4f84f1fca21bb803d28b49d12df","size":"886KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec037c8524"],"type_of_change":"0","version":"12.0.1171.0"}],"id":{"product":"70f19ffffee546149605e6df93bd9de3","version":"0ce26dd3cd4744ca9f29d5a742fa7ceb"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>\n          [インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex 10/20 GbE iSCSI Driver for Windows Server 2016"},{"lang":"ja","x_late":"HPE Emulex 10/20 GbE iSCSIドライバー for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"320"},"supported_devices":[{"dev":"0722","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c220a","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c21d4","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c8144","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072215908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-12T06:00:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now remove&nbsp;supports Synergy and Blade&nbsp;Server.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p style=\"text-align:left\">This product now supports the following network adapters:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"}],"sw_keys":[{"name":"be2iscsi.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GWDFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEAHasseFG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304757444645","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB012000GWDFE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB012000GWDFE Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"18558580","datemodified":"2021-08-26T12:59:44","file_list":["/CP048335_BUILD_2.data","/CP048335.vmexe","/CP048335.vmexe64","/CP048335.vmfile","/CP048335_VMw.zip","/CP048335.xml","/payload.json","/CP048335_VMw.zip/index.xml","/CP048335_VMw.zip/vendor-index.xml","/CP048335_VMw.zip/metadata.zip","/CP048335_VMw.zip/vib20/CP048335/HPE_bootbank_CP048335_HPG3.2-7.0.0.15843807.vib","/CP048335_VMw.zip/metadata.zip/vendor-index.xml","/CP048335_VMw.zip/metadata.zip/vmware.xml","/CP048335_VMw.zip/metadata.zip/vibs/CP048335-3368829359354883197.xml","/CP048335_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048335_HPG3.2-7.0.0.15843807.xml"],"md5sum":"f481ed1916a806848a557b7ac092c6c1","name":"CP048335.zip","release":"2021-08-26T12:54:40","revision":"0","sha1sum":"e8dadd74495f2b377ad630d4451315b4c2f4fe5c","size":"17MB","target_guids":["4d2340a5-3042-3231-3030-304757444645"],"type_of_change":"1","version":"HPG3","vib_list":[{"name":"CP048335","version":"HPG3.2-7.0.0.15843807"}]}],"id":{"product":"6973afa059034a93b5842e17d11d1b46","version":"0ad78e0db597495a989eafc1c0f5c16b"},"installation":{"command":"CP042747.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB012000GWDFE Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB012000GWDFEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB012000GWDFE","target_guid":"4d2340a5-3042-3231-3030-304757444645","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-05T20:05:27","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB012000GWDFE","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GWDFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEAHasseFG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304757444645","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB012000GWDFE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;&nbsp;MB012000GWDFE Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"6044724","datemodified":"2021-07-23T07:21:25","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG3-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG3-2.1/CP048137.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG3-2.1/HLEAHasseFG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG3-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048137.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048137.scexe"],"md5sum":"48ae07ad5f154813cfd5c73f0f0732dd","name":"firmware-hdd-059b8654a6-HPG3-2.1.x86_64.rpm","release":"2021-07-23T07:09:09","revision":"0","sha1sum":"914964959a7648f7d9554358cc9bf7fa4eb09418","size":"5MB","target_guids":["4d2340a5-3042-3231-3030-304757444645"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"ae7662457b594bb08733bceba6635c72","version":"fa5acad2d85e42cdaefd0f2b69d88fc8"},"installation":{"command":"CP040337.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB012000GWDFE Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB012000GWDFEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB012000GWDFE","target_guid":"4d2340a5-3042-3231-3030-304757444645","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-26T12:05:09","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB012000GWDFE","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWTBK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304a5754424b","Version":"HPD9"},{"DeviceName":"VO001920JWTBL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304a5754424c","Version":"HPD9"},{"DeviceName":"VO003840JWTBN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304a5754424e","Version":"HPD9"},{"DeviceName":"VO007680JWTBP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304a57544250","Version":"HPD9"},{"DeviceName":"MO000400JWTBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57544251","Version":"HPD9"},{"DeviceName":"MO000800JWTBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57544252","Version":"HPD9"},{"DeviceName":"MO001600JWTBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57544254","Version":"HPD9"},{"DeviceName":"MO003200JWTBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57544255","Version":"HPD9"},{"DeviceName":"MO006400JWTCD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a57544344","Version":"HPD9"},{"DeviceName":"EO000400JWTBV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57544256","Version":"HPD9"},{"DeviceName":"EO000800JWTCA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57544341","Version":"HPD9"},{"DeviceName":"EO001600JWTCB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57544342","Version":"HPD9"},{"DeviceName":"EO003200JWTCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3330-3230-304a57544343","Version":"HPD9"},{"DeviceName":"MO001920JWWWV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a57575756","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA, EO001600JWTCB, EO003200JWTCC and MO001920JWWWV"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO000960JWTBK、VO001920JWTBL、VO003840JWTBN、VO007680JWTBP、MO000400JWTBQ、MO000800JWTBR、MO001600JWTBT、MO003200JWTBU、MO006400JWTCD、EO000400JWTBV、EO000800JWTCA、EO001600JWTCB、EO003200JWTCC およびMO001920JWWWV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA, EO001600JWTCB, EO003200JWTCC and MO001920JWWWV Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16157116","datemodified":"2021-08-30T04:42:56","file_list":["/CP049147_BUILD_1.data","/CP049147.vmexe","/CP049147.vmexe64","/CP049147.vmfile","/CP049147_VMw.zip","/CP049147.xml","/payload.json","/CP049147_VMw.zip/index.xml","/CP049147_VMw.zip/vendor-index.xml","/CP049147_VMw.zip/metadata.zip","/CP049147_VMw.zip/vib20/CP049147/HPE_bootbank_CP049147_HPD9.1-7.0.0.15843807.vib","/CP049147_VMw.zip/metadata.zip/vendor-index.xml","/CP049147_VMw.zip/metadata.zip/vmware.xml","/CP049147_VMw.zip/metadata.zip/vibs/CP049147--5481401386907158129.xml","/CP049147_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049147_HPD9.1-7.0.0.15843807.xml"],"md5sum":"1fbaf91e2e99444f57565c6485869253","name":"CP049147.zip","release":"2021-08-30T04:37:59","revision":"0","sha1sum":"38cd50bf3735497473860afff42e0daa6c88156d","size":"15MB","target_guids":["562340a5-304f-3030-3936-304a5754424b","562340a5-304f-3130-3932-304a5754424c","562340a5-304f-3330-3834-304a5754424e","562340a5-304f-3730-3638-304a57544250","4d2340a5-304f-3030-3430-304a57544251","4d2340a5-304f-3030-3830-304a57544252","4d2340a5-304f-3130-3630-304a57544254","4d2340a5-304f-3330-3230-304a57544255","4d2340a5-304f-3630-3430-304a57544344","452340a5-304f-3030-3430-304a57544256","452340a5-304f-3030-3830-304a57544341","452340a5-304f-3130-3630-304a57544342","452340a5-304f-3330-3230-304a57544343","4d2340a5-304f-3130-3932-304a57575756"],"type_of_change":"1","version":"HPD9","vib_list":[{"name":"CP049147","version":"HPD9.1-7.0.0.15843807"}]}],"id":{"product":"7004592a3bf74fab99a6fe756662ebbc","version":"ac5301788a5b4005bdc23be08a1c50c2"},"installation":{"command":"CP040758.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA, EO001600JWTCB  Drives"},{"lang":"ja","x_late":"オンライン HDD/SSDフラッシュコンポーネント for VMware ESXi  - VO000960JWTBK、VO001920JWTBL、VO003840JWTBN、VO007680JWTBP、MO000400JWTBQ、MO000800JWTBR、MO001600JWTBT、MO003200JWTBU、MO006400JWTCD、EO000400JWTBV、EO000800JWTCA、EO001600JWTCB ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VO007680JWTBP","target_guid":"562340a5-304f-3730-3638-304a57544250","type":"sas"},{"id":"MO006400JWTCD","target_guid":"4d2340a5-304f-3630-3430-304a57544344","type":"sas"},{"id":"VO003840JWTBN","target_guid":"562340a5-304f-3330-3834-304a5754424e","type":"sas"},{"id":"MO003200JWTBU","target_guid":"4d2340a5-304f-3330-3230-304a57544255","type":"sas"},{"id":"EO003200JWTCC","target_guid":"452340a5-304f-3330-3230-304a57544343","type":"sas"},{"id":"VO001920JWTBL","target_guid":"562340a5-304f-3130-3932-304a5754424c","type":"sas"},{"id":"MO001600JWTBT","target_guid":"4d2340a5-304f-3130-3630-304a57544254","type":"sas"},{"id":"EO001600JWTCB","target_guid":"452340a5-304f-3130-3630-304a57544342","type":"sas"},{"id":"VO000960JWTBK","target_guid":"562340a5-304f-3030-3936-304a5754424b","type":"sas"},{"id":"MO000800JWTBR","target_guid":"4d2340a5-304f-3030-3830-304a57544252","type":"sas"},{"id":"EO000800JWTCA","target_guid":"452340a5-304f-3030-3830-304a57544341","type":"sas"},{"id":"MO000400JWTBQ","target_guid":"4d2340a5-304f-3030-3430-304a57544251","type":"sas"},{"id":"EO000400JWTBV","target_guid":"452340a5-304f-3030-3430-304a57544256","type":"sas"},{"id":"MO001920JWWWV","target_guid":"4d2340a5-304f-3130-3932-304a57575756","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T20:00:11","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Change Vendor Identification Field (VID data) from &quot;HP&quot; to &quot;HPE&quot;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EO000400JWTBV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001920JWWWV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920JWTBL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600JWTBT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO001600JWTCB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000800JWTCA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800JWTBR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000960JWTBK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO007680JWTBP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200JWTBU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO006400JWTCD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000400JWTBQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003840JWTBN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO003200JWTCC","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The HPE System Health Application and Command Line Utilities (hp-health) is collection of applications and tools which enables monitoring of fans, power supplies, temperature sensors, and other management events.  It also provides collection of command-line utilities: the ProLiant  boot  configuration  utility (hpbootcfg), the ProLiant Management Command Line Interface Utility (hpasmcli), the ProLiant Integrated Management Log (IML) Utility (hplog), and the UID (blue) Light Utility (hpuid)."},{"lang":"ja","x_late":"HPEシステムヘルスアプリケーションおよびコマンドラインユーティリティ(hp-health)パッケージは、アプリケーション、およびファンの監視、電源、温度センサー、およびその他管理イベントを行うツールを集めたものです。また、コマンドラインユーティリティのコレクションを提供します: ProLiantブート構成ユーティリティ(hpbootcfg)、ProLiant管理コマンドラインインターフェイスユーティリティ(hpasmcli)、ProLiantインテグレーテッドマネジメントログ(IML)ユーティリティ(hplog)、およびUID(blue)ライトユーティリティ(hpuid)。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[],"files":[{"bytes":"535229","datemodified":"2021-08-25T02:55:12","file_list":["./opt/hp/hp-health","./opt/hp/hp-health/addons","./opt/hp/hp-health/addons/libcpqci64.a","./opt/hp/hp-health/bin","./opt/hp/hp-health/bin/hp-asrd","./opt/hp/hp-health/bin/hpasmlited","./opt/hp/hp-health/bin/hpasmpld","./opt/hp/hp-health/bin/hpasmxld","./opt/hp/hp-health/examples","./opt/hp/hp-health/examples/lite-mgmt","./opt/hp/hp-health/examples/lite-mgmt/COPYING.txt","./opt/hp/hp-health/examples/lite-mgmt/README.txt","./opt/hp/hp-health/examples/lite-mgmt/cma.conf.nosnmp","./opt/hp/hp-health/examples/lite-mgmt/hpsysmon.sh","./opt/hp/hp-health/hp-health.license","./opt/hp/hp-health/hprpm.xpm","./opt/hp/hp-health/sh","./opt/hp/hp-health/sh/hpasmxld_reset.sh","./sbin/hpasmcli","./sbin/hpbootcfg","./sbin/hplog","./sbin/hpuid","./sbin/rchp-health","./usr/lib/systemd/scripts/hp-asrd.sh","./usr/lib/systemd/scripts/hp-health.sh","./usr/lib/systemd/system/hp-asrd.service","./usr/lib/systemd/system/hp-health.service","./usr/lib64/libcpqci64.so","./usr/lib64/libcpqci64.so.3","./usr/lib64/libcpqci64.so.3.0","./usr/lib64/libhpasmintrfc64.so","./usr/lib64/libhpasmintrfc64.so.3","./usr/lib64/libhpasmintrfc64.so.3.0","./usr/lib64/libhpev64.so","./usr/lib64/libhpev64.so.1","./usr/lib64/libhpev64.so.1.0","./usr/share/man/man4/hp-health.4.gz","./usr/share/man/man4/hpasmcli.4.gz","./usr/share/man/man7/hp_mgmt_install.7.gz","./usr/share/man/man8/hp-asrd.8.gz","./usr/share/man/man8/hpbootcfg.8.gz","./usr/share/man/man8/hplog.8.gz","./usr/share/man/man8/hpuid.8.gz","./usr/share/smartupdate/hp-health/component.xml","./var/log/hp-health","./var/spool/compaq","./var/spool/hp-health"],"md5sum":"b45c3831507aa1a72c2ed285fff3c653","name":"hp-health-10.93-307.5.sles15.x86_64.rpm","release":"2021-08-25T02:46:27","revision":"0","sha1sum":"d3e9ec69d96bbb6d46488330f9ef88a9e0fe046c","size":"522KB","target_guids":[],"type_of_change":"0","version":"10.9.3"}],"id":{"product":"b243398aaeca47f7be44fb080b998e4c","version":"2a7a45fbc3f245598a5bc01374995af0"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<P>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</P>\n<P>To install the package type: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;rpm -ivh hp-health-&lt;version&gt;.rpm</P>\n<P>To check whether the package is loaded properly type: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;/etc/init.d/hp-health status</P>\n<P>Additional help is available by typing: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;man hp-health</P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;or</P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;man hp_mgmt_install</P>"},{"lang":"ja","x_late":"<P>システム管理者（root）としてログインし、RPMをご使用のハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</P>\n<P>パッケージをインストールするには、次のようにタイプします。</P>\n<P>      rpm -ivh hp-health-<version>.rpm</P>\n<P>パッケージが正しくロードされているか、以下をタイプして確認します。</P>\n<P>      /etc/init.d/hp-health status</P>\n<P>以下のコマンドを実行してヘルプを参照してください。</P>\n<P>      man hp-health</P>\n<P>            または</P>\n<P>      man hp_mgmt_install</P>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE System Health Application and Command Line Utilities for SUSE LINUX Enterprise Server 15"},{"lang":"ja","x_late":"HPEシステムヘルスアプリケーションおよびコマンドラインユーティリティ for SUSE LINUX Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"3309","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3307","subdev":"3309","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3306","subdev":"330e","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3307","subdev":"330e","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-10T13:28:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Enhancements included in this release:</p>\n\n<ul>\n\t<li>Support for SUSE Linux Enterprise Server 15 Service Pack 2</li>\n</ul>\n","latest_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>When a customer queries the HPE Software Delivery Repository (SDR) site and experiences a failure amsd no longer exhibits a&nbsp;segfault.</li>\n\t<li>hp-heath service will no longer crash in a non&nbsp;secure boot environment.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>TBD</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"}],"sw_keys":[{"name":"hp-health","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GWCEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757434556","Version":"HPG3"},{"DeviceName":"MK000960GWCFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757434641","Version":"HPG3"},{"DeviceName":"MK001920GWCFB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304757434642","Version":"HPG3"},{"DeviceName":"MK000240GWCEU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3234-304757434555","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MK000240GWCEU, MK000480GWCEV, MK000960GWCFA and MK001920GWCFB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MK000240GWCEU, MK000480GWCEV, MK000960GWCFA and MK001920GWCFB Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"2811176","datemodified":"2021-07-25T17:06:36","file_list":["cp048624.xml","cpqsetup.exe","GS863aG3.rel","payload.json","setup.dll"],"md5sum":"db7d327828cfa37d023efa9730016dee","name":"cp048624.exe","release":"2021-07-25T16:59:05","revision":"0","sha1sum":"17ed42d1ff46df8c6ad47e28d2288fcd26121807","size":"2MB","target_guids":["4d2340a5-304b-3030-3438-304757434556","4d2340a5-304b-3030-3936-304757434641","4d2340a5-304b-3130-3932-304757434642","4d2340a5-304b-3030-3234-304757434555"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"707803ff432e4432b9c2ea604ffe836c","version":"dac48784422f4d5b9c8ea5e99c30643d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"text-decoration-line: none; color: blue;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MK000240GWCEU, MK000480GWCEV, MK000960GWCFA and MK001920GWCFB Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64)- MK000240GWCEU、MK000480GWCEV、MK000960GWCFAおよびMK001920GWCFBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MK001920GWCFB","target_guid":"4d2340a5-304b-3130-3932-304757434642","type":"sata"},{"id":"MK000240GWCEU","target_guid":"4d2340a5-304b-3030-3234-304757434555","type":"sata"},{"id":"MK000480GWCEV","target_guid":"4d2340a5-304b-3030-3438-304757434556","type":"sata"},{"id":"MK000960GWCFA","target_guid":"4d2340a5-304b-3030-3936-304757434641","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T13:12:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK000240GWCEU","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWCFA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK001920GWCFB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWCEV","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This package updates the I/O module firmware on HPE D3600, D3700, D3610 and D3710 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"5035136","datemodified":"2021-09-14T14:16:13","file_list":["Config.xml","cp048694.xml","cpqsetup.exe","Microsoft.VC90.CRT.manifest","msvcp110.dll","msvcp90.dll","msvcr110.dll","msvcr90.dll","payload.json","Reveille-Release-5.04-build-000.bin","VDUFlash.dll"],"md5sum":"3874162f8c33e347f71281816bdbc9bf","name":"cp048694.exe","release":"2021-09-14T14:14:26","revision":"0","sha1sum":"551a1393524b5a7d821370994b8d9aaa21be5eb2","size":"4MB","target_guids":[],"type_of_change":"1","version":"5.04"}],"id":{"product":"a980cd7ae1d94bb9a3c6b502c66d4fa7","version":"94ff11fd263c4b18bfe6e25c10fba620"},"installation":{"command":"cpqsetup.exe","command_params":"/tD3600 /tD3700 /tD3610 /tD3710 /v5.04 /iReveille-Release-5.04-build-000.bin /lD3000.log","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":900,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Windows Smart Component Installation Instructions:</strong></p>\n\n<p>This is a self extracting executable module. One can execute this module via the&nbsp;command line console or from&nbsp;Windows graphical user interface.</p>\n\n<p><strong>GUI Option:</strong></p>\n\n<ol>\n\t<li>Place the downloaded firmware package in a temporary directory.</li>\n\t<li>Using Windows Explorer, navigate to the directory containing the download.</li>\n\t<li>Double click the executable file.</li>\n\t<li>Follow onscreen instructions.&nbsp;After you are prompted for logon information, enter credentials for an account with management access rights.</li>\n</ol>\n\n<p><strong>CLI Option:</strong></p>\n\n<p>Execute the Smart Component by entering the following command: CP0xxxxx.exe /s</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong></p>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages.</li>\n\t<li>Run the launch_sum.bat in the root of the ISO.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n\n<p><strong>NOTES: </strong>OPTIONS for in band enclosure flash:</p>\n\n<p><strong>Parameter</strong> &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<strong>Description</strong><br />\n-----------------------------------------------------------------------------<br />\n<strong>/h,/?&nbsp;</strong>&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;Displays command line usage help(dialog box)<br />\n<strong>/s </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Installs without user interaction</p>\n\n<p><strong>The following command&nbsp;is&nbsp;applicable only with /s:</strong><br />\n<strong>/f </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Allow a downgrade or reinstall if already up to date</p>\n\n<p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p652416360/v202887/20_D3000_Gen9RN504C_ED1.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE D3600/D3700/D3610/D3710 12Gb SAS Disk Enclosure ROM Flash Component for Windows (x64)"}],"prerequisites":{"required_diskspace":{"size_kb":"2"},"supported_devices":[{"id":"D3600","target_guid":"","type":"sas"},{"id":"D3700","target_guid":"","type":"sas"},{"id":"D3610","target_guid":"","type":"sas"},{"id":"D3710","target_guid":"","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-17T11:34:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p>\n\n<ul>\n\t<li>\n\t<p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p>\n\t</li>\n\t<li>\n\t<p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p>\n\t</li>\n\t<li>\n\t<p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p>\n\t</li>\n\t<li>\n\t<p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p>\n\t</li>\n</ul>\n\n<p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p652416360/v202887/20_D3000_Gen9RN504C_ED1.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"}],"sw_keys":[{"name":"D3710","sw_key_expectedpath":"firmware:sd:disk_enclosure"},{"name":"D3610","sw_key_expectedpath":"firmware:sd:disk_enclosure"},{"name":"D3600","sw_key_expectedpath":"firmware:sd:disk_enclosure"},{"name":"D3700","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001920KWZQR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173300HPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304b575a5152","Version":"HPK5"},{"DeviceName":"VO003840KWZQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173300HPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304b575a5154","Version":"HPK5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO001920KWZQR and VO003840KWZQT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;NVMe SSD&nbsp;Flash Component for Linux (x64) - VO001920KWZQR and VO003840KWZQT Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n\n<p style=\"text-align:left\"><strong>Known Issues:</strong></p>\n\n<p style=\"text-align:left\">&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"9400814","datemodified":"2021-07-25T12:31:58","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-2af7385a1e-HPK5-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-2af7385a1e-HPK5-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-2af7385a1e-HPK5-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2af7385a1e-HPK5-4.1/CP048238.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-2af7385a1e-HPK5-4.1/GP173300HPK5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-2af7385a1e-HPK5-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2af7385a1e-HPK5-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-2af7385a1e-HPK5-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-2af7385a1e-HPK5-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048238.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048238.scexe"],"md5sum":"a10cf1e1bd07cbe479d33347d1c365e2","name":"firmware-hdd-2af7385a1e-HPK5-4.1.x86_64.rpm","release":"2021-07-25T12:18:13","revision":"0","sha1sum":"486f7bab1c33f37f8769ae8c76ff2516a80f6d41","size":"8MB","target_guids":["562340a5-304f-3130-3932-304b575a5152","562340a5-304f-3330-3834-304b575a5154"],"type_of_change":"2","version":"HPK5"}],"id":{"product":"18e9f59fd9934421b3a1eafac327542f","version":"404b375e73944e9b9a29f14fe1ecce1a"},"installation":{"command":"CP041863.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left: 30pt;\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left: 30pt;\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - VO001920KWZQR and VO003840KWZQT Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - VO001920KWZQRおよびVO003840KWZQTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VO003840KWZQT","target_guid":"562340a5-304f-3330-3834-304b575a5154","type":"nvme"},{"id":"VO001920KWZQR","target_guid":"562340a5-304f-3130-3932-304b575a5152","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-01T07:45:49","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO003840KWZQT","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO001920KWZQR","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Intel ixt 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1033120","datemodified":"2021-01-08T20:08:44","file_list":["cp045874.xml","cpqsetup.exe","cp_data.xml","install.xml","ixt68x64.cat","ixt68x64.din","ixt68x64.inf","ixt68x64.sys","ixtmsg.dll","nicdrvr.dll"],"md5sum":"d5bea19b3c46f33debcbae2f5e32c246","name":"cp045874.exe","release":"2021-01-08T19:47:05","revision":"0","sha1sum":"79e43d7defb38e252369bff389e8ec1bd6616721","size":"0MB","target_guids":[],"type_of_change":"0","version":"4.1.197.0"}],"id":{"product":"47e104da8d1247009422e246e7ae204a","version":"d7b50fb0b8a3400b9b25b995852e8633"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel ixt Driver for Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial version</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"03020101","value":"HPE Superdome Flex Server"}],"sw_keys":[{"name":"ixt68x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWTHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757544841","Version":"HPG3"},{"DeviceName":"VK000960GWTHB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757544842","Version":"HPG3"},{"DeviceName":"VK001920GWTHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757544843","Version":"HPG3"},{"DeviceName":"VK003840GWTHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304757544844","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3862352","datemodified":"2021-08-13T14:48:40","file_list":["cp049277.xml","cpqsetup.exe","K401HPG3.rel","payload.json","setup.dll"],"md5sum":"5523aa73f5494cb9d7d302c793a967b0","name":"cp049277.exe","release":"2021-08-13T14:40:27","revision":"0","sha1sum":"5671e71607652e77877f3970aeffe1433a383bdb","size":"3MB","target_guids":["562340a5-304b-3030-3438-304757544841","562340a5-304b-3030-3936-304757544842","562340a5-304b-3130-3932-304757544843","562340a5-304b-3330-3834-304757544844"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"8e8fd25144334177930f2db95d492320","version":"763c5f7344ee463caf82efecad197a87"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"text-decoration-line: none; color: blue;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -VK000480GWTHA、VK000960GWTHB、VK001920GWTHC、およびVK003840GWTHDドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VK003840GWTHD","target_guid":"562340a5-304b-3330-3834-304757544844","type":"sata"},{"id":"VK001920GWTHC","target_guid":"562340a5-304b-3130-3932-304757544843","type":"sata"},{"id":"VK000960GWTHB","target_guid":"562340a5-304b-3030-3936-304757544842","type":"sata"},{"id":"VK000480GWTHA","target_guid":"562340a5-304b-3030-3438-304757544841","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-13T14:35:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This maintenance FW release addresses a rare corner case COMRESET issue at warm boot, and to address an early EOL behavior under certain use cases.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK001920GWTHC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GWTHD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWTHA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWTHB","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWFVK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATdsHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a5746564b","Version":"HPD4"},{"DeviceName":"MB006000JWFVL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATdsHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a5746564c","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB004000JWFVK and MB006000JWFVL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB004000JWFVK and MB006000JWFVL&nbsp;Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4893651","datemodified":"2021-07-23T08:10:49","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-f6d00bd17e-HPD4-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-f6d00bd17e-HPD4-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-f6d00bd17e-HPD4-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-f6d00bd17e-HPD4-2.1/CP048100.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-f6d00bd17e-HPD4-2.1/TATCATdsHPD4.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-f6d00bd17e-HPD4-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-f6d00bd17e-HPD4-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-f6d00bd17e-HPD4-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-f6d00bd17e-HPD4-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048100.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048100.scexe"],"md5sum":"31302f9f366de8fc64b506c66c67a3c5","name":"firmware-hdd-f6d00bd17e-HPD4-2.1.x86_64.rpm","release":"2021-07-23T07:58:10","revision":"0","sha1sum":"3a2261b90ccc8798fa9f4614d59ae643786ee199","size":"4MB","target_guids":["4d2340a5-3042-3430-3030-304a5746564b","4d2340a5-3042-3630-3030-304a5746564c"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"07fc1a5a961a427ba3c2e3f341d3886e","version":"e5329206cea246008584e19ee21650c1"},"installation":{"command":"CP041750.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64)  - MB004000JWFVK and MB006000JWFVL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB004000JWFVKおよびMB006000JWFVLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB004000JWFVK","target_guid":"4d2340a5-3042-3430-3030-304a5746564b","type":"sas"},{"id":"MB006000JWFVL","target_guid":"4d2340a5-3042-3630-3030-304a5746564c","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T12:52:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>There is no compelling reason to update this firmware. Risk is that whoever looks at the Vendor ID in the VPD page will notice that it refers to HP instead of HPE. There is no functional risk if not upgraded.&nbsp;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB004000JWFVK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB006000JWFVL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EK0800JVYPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304b-3830-304a5659504e","Version":"HPD7"},{"DeviceName":"EO1600JVYPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-314f-3630-304a56595050","Version":"HPD7"},{"DeviceName":"MK0800JVYPQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304b-3830-304a56595051","Version":"HPD7"},{"DeviceName":"MO1600JVYPR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304a56595052","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EK0800JVYPN, EO1600JVYPP, MK0800JVYPQ and MO1600JVYPR"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EK0800JVYPN, EO1600JVYPP, MK0800JVYPQ and MO1600JVYPR Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD7</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD7 that results in SSD failure at 40,000 hours of operation (i.e., 4 years, 205 days 16 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us\" style=\"color: blue; text-decoration: none;\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us</a>.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"16842257","datemodified":"2021-08-27T11:52:48","file_list":["/CP048429_BUILD_3.data","/CP048429.vmexe","/CP048429.vmexe64","/CP048429.vmfile","/CP048429_VMw.zip","/CP048429.xml","/payload.json","/CP048429_VMw.zip/index.xml","/CP048429_VMw.zip/vendor-index.xml","/CP048429_VMw.zip/metadata.zip","/CP048429_VMw.zip/vib20/CP048429/HPE_bootbank_CP048429_HPD7.3-7.0.0.15843807.vib","/CP048429_VMw.zip/metadata.zip/vendor-index.xml","/CP048429_VMw.zip/metadata.zip/vmware.xml","/CP048429_VMw.zip/metadata.zip/vibs/CP048429-1200317002224867721.xml","/CP048429_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048429_HPD7.3-7.0.0.15843807.xml"],"md5sum":"8f82cc26c43c5ca0fdcc4a08caa4dcba","name":"CP048429.zip","release":"2021-08-27T11:48:13","revision":"0","sha1sum":"01546baba93b3007f1b35e8db97d2fa1068e97ea","size":"16MB","target_guids":["002340a5-4500-304b-3830-304a5659504e","002340a5-4500-314f-3630-304a56595050","002340a5-4d00-304b-3830-304a56595051","002340a5-4d00-314f-3630-304a56595052"],"type_of_change":"2","version":"HPD7","vib_list":[{"name":"CP048429","version":"HPD7.3-7.0.0.15843807"}]}],"id":{"product":"09b4bcb98476436f9711a4ef6ff6b585","version":"5a89b51f58f94330b0808d9a1f641caa"},"installation":{"command":"CP043253.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EK0800JVYPN, EO1600JVYPP, MK0800JVYPQ and MO1600JVYPR Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EK0800JVYPN、EO1600JVYPP、MK0800JVYPQ、およびMO1600JVYPRドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MO1600JVYPR","target_guid":"002340a5-4d00-314f-3630-304a56595052","type":"sas"},{"id":"EO1600JVYPP","target_guid":"002340a5-4500-314f-3630-304a56595050","type":"sas"},{"id":"MK0800JVYPQ","target_guid":"002340a5-4d00-304b-3830-304a56595051","type":"sas"},{"id":"EK0800JVYPN","target_guid":"002340a5-4500-304b-3830-304a5659504e","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-10T07:56:11","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>&nbsp;Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD7 that results in SSD failure at 40,000 hours of operation (i.e., 4 years, 205 days 16 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us\" style=\"color: blue; text-decoration: none;\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us</a>.</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD7 that results in SSD failure at 40,000 hours of operation (i.e., 4 years, 205 days 16 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us\" style=\"color: blue; text-decoration: none;\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us</a>.</li>\n</ul>","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EK0800JVYPN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO1600JVYPP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO1600JVYPR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MK0800JVYPQ","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following storage controllers: Smart Array P220i, P222, P420i, P420, P421, P721m, and P822"},{"lang":"cn","x_late":"该 Smart Component 可为以下存储控制器提供固件： 智能阵列 P220i、P222、P420i、P420、P421、P721m 和 P822"},{"lang":"tw","x_late":"此智慧型元件提供適用於下列儲存控制器的韌體： Smart Array P220i、P222、P420i、P420、P421、P721m 與 P822"},{"lang":"ko","x_late":"이 스마트 구성 요소는 다음 스토리지 컨트롤러용 펌웨어를 제공합니다. 스마트 어레이 P220i, P222, P420i, P420, P421, P721m 및 P822"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のストレージコントローラーのファームウェアを提供します。 SmartアレイP220i、P222、P420i、P420、P421、P721m、およびP822"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online ROM Flash Component for VMware ESXi - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 8.32(D)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 8.32(C)<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 8.32(C)</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Added support for ESXi 7.0</p>\n\t</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"25567173","datemodified":"2020-08-28T03:26:38","file_list":["/CP045344.vmexe","/CP045344.vmexe64","/CP045344.vmfile","/CP045344.xml","/payload.json","/README.txt"],"md5sum":"9006f9f9715e6965c8c451717abae65e","name":"CP045344.zip","release":"2020-08-28T03:12:09","revision":"0","sha1sum":"c4ba54d32077a5a85bebc6e650fae4ce0e442f4b","size":"24MB","target_guids":[],"type_of_change":"1","version":"8.32","vib_list":[]}],"id":{"product":"191698dcecb7439eb6e537a0877ed0e1","version":"a6915b77f1284ff488472fe13fc5de03"},"installation":{"command":"CP045344.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActiveIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Smart Array HPCISSS3 Controller Driver version 100.18.2.64 must not be used for firmware update.  Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfd368f11","ServerModel":["*"],"Target_guids":[],"Type":"NE","Version":"100.18.2.64","description":"HPE ProLiant Smart Array HPCISSS3 Controller Driver version 100.18.2.64 must not be used for firmware update.  Update the driver and reboot before attempting firmware update."}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;<strong>Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run Smart Update Manager (SUM).</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For Smart Update Manager (SUM) 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at: <a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;<br />\n<strong>To use HPE Insight Control for vCenter:</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPXXXXXX.vmexe&nbsp; &nbsp; or chmod +x CPXXXXX.vmexe64 (for ESXi7.0)</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe or ./CPXXXXX.vmexe64 (for ESXi7.0)</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware ESXi - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822"},{"lang":"cn","x_late":"面向 VMware ESXi 的在线 ROM Flash 组件 - 智能阵列 P220i、P222、P420i、P420、P421、P721m 和 P822"},{"lang":"tw","x_late":"適用於 VMware ESXi 的線上 ROM 更新元件 - Smart Array P220i、P222、P420i、P420、P421、P721m 與 P822"},{"lang":"ko","x_late":"VMware ESXi용 온라인 ROM 플래시 구성 요소 - 스마트 어레이 P220i, P222, P420i, P420, P421, P721m, P822"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for VMware ESXi - SmartアレイP220i、P222、P420i、P420、P421、P721m、およびP822"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"323b","subdev":"3352","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3351","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3354","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3350","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3355","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3353","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323B","subdev":"3356","subven":"103C","target_guid":"","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-24T10:29:07","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support for ESXi 7.0</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added support for ESXi 7.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P74","value":"HP ProLiant SL140s Gen8 Server (private)"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"}],"sw_keys":[{"name":"3355103c","sw_key_expectedpath":"firmware"},{"name":"3352103c","sw_key_expectedpath":"firmware"},{"name":"3356103C","sw_key_expectedpath":"firmware"},{"name":"3351103c","sw_key_expectedpath":"firmware"},{"name":"D2220sb","sw_key_expectedpath":"firmware"},{"name":"3350103c","sw_key_expectedpath":"firmware"},{"name":"3354103c","sw_key_expectedpath":"firmware"},{"name":"3353103c","sw_key_expectedpath":"firmware"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWJRQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a574a5251","Version":"HPD9"},{"DeviceName":"MB006000JWJRP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574a5250","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB008000JWJRQ and MB006000JWJRP"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB008000JWJRQおよびMB006000JWJRP"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB008000JWJRQ and MB006000JWJRP Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>This firmware release provides additional protection against command timeouts.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3032464","datemodified":"2021-08-12T20:01:47","file_list":["cp049130.xml","cpqsetup.exe","payload.json","setup.dll","TAMG06scHPD9.REL"],"md5sum":"621d4170339fe9fabcdc84447c364a3a","name":"cp049130.exe","release":"2021-08-12T19:52:08","revision":"0","sha1sum":"1e811b8fedf32ad1f0041adcf9718d72c0d3840a","size":"2MB","target_guids":["4d2340a5-3042-3830-3030-304a574a5251","4d2340a5-3042-3630-3030-304a574a5250"],"type_of_change":"1","version":"HPD9"}],"id":{"product":"0c95f7c054f047b69fbfe7c93264a982","version":"5cfad832192d444688629fb24108326c"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB008000JWJRQ and MB006000JWJRP Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB008000JWJRQおよび MB006000JWJRPドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB008000JWJRQ","target_guid":"4d2340a5-3042-3830-3030-304a574a5251","type":"sas"},{"id":"MB006000JWJRP","target_guid":"4d2340a5-3042-3630-3030-304a574a5250","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T16:39:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This firmware release provides additional protection against command timeouts.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This firmware release provides additional protection against command timeouts.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000JWJRQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB006000JWJRP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JWKGN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAeAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574b474e","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB006000JWKGN"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB006000JWKGN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB006000JWKGN Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD1<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp; </strong>None</p>\n"}],"files":[{"bytes":"4303064","datemodified":"2021-07-23T18:23:01","file_list":["cp048677.xml","cpqsetup.exe","HVLAeAsseFD2.rel","payload.json","setup.dll"],"md5sum":"ebecbee7fb53861b9c545b0aba9fa6de","name":"cp048677.exe","release":"2021-07-23T18:15:05","revision":"0","sha1sum":"809dde939024709ce92767dc8c47204d43a5be6c","size":"4MB","target_guids":["4d2340a5-3042-3630-3030-304a574b474e"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"3c5ca1f7884d46278989b90e474b83e1","version":"6aed724779ac4ec68b94959e4e7d2edb"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB006000JWKGN Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB006000JWKGN ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB006000JWKGN","target_guid":"4d2340a5-3042-3630-3030-304a574b474e","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-17T08:54:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000JWKGN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001000KWJSE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3030-304b574a5345","Version":"4ICDHPK1"},{"DeviceName":"VO002000KWJSF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3230-3030-304b574a5346","Version":"4ICDHPK1"},{"DeviceName":"VO004000KWJSH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3430-3030-304b574a5348","Version":"4ICDHPK1"},{"DeviceName":"VT004000KWJSU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3054-3430-3030-304b574a5355","Version":"4ICDHPK1"},{"DeviceName":"MO001600KWJSN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b574a534e","Version":"4ICDHPK1"},{"DeviceName":"MO003200KWJSQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b574a5351","Version":"4ICDHPK1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO001000KWJSE, VO002000KWJSF, VO004000KWJSH, VT004000KWJSU, MO001600KWJSN and MO003200KWJSQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Linux (x64) - VO001000KWJSE, VO002000KWJSF, VO004000KWJSH, VT004000KWJSU, MO001600KWJSN and MO003200KWJSQ Drives</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>This firmware corrects the potential for a drive to become disabled and nonfunctional during certain conditions or workloads.</li>\n\t<li>After the drive is upgraded to firmware version HPK1, it cannot be downgraded to firmware version HPK0.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong>&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"4951010","datemodified":"2021-07-25T12:33:49","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-1656c1b14a-4ICDHPK1-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-1656c1b14a-4ICDHPK1-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-1656c1b14a-4ICDHPK1-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-1656c1b14a-4ICDHPK1-2.1/4ICDHPK1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-1656c1b14a-4ICDHPK1-2.1/CP048506.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-1656c1b14a-4ICDHPK1-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-1656c1b14a-4ICDHPK1-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-1656c1b14a-4ICDHPK1-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-1656c1b14a-4ICDHPK1-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048506.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048506.scexe"],"md5sum":"cf0fe46c261c0dd9272e9a5b4554ba29","name":"firmware-hdd-1656c1b14a-4ICDHPK1-2.1.x86_64.rpm","release":"2021-07-25T12:22:04","revision":"0","sha1sum":"e31a475ab5ea40f7992910b07b7bef6b379c9e60","size":"4MB","target_guids":["562340a5-304f-3130-3030-304b574a5345","562340a5-304f-3230-3030-304b574a5346","562340a5-304f-3430-3030-304b574a5348","562340a5-3054-3430-3030-304b574a5355","4d2340a5-304f-3130-3630-304b574a534e","4d2340a5-304f-3330-3230-304b574a5351"],"type_of_change":"2","version":"4ICDHPK1"}],"id":{"product":"288dbea3acd4439082f94ee3a892bf62","version":"23c38495249f4006bf966b835978b389"},"installation":{"command":"CP043037.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p><strong>Additional Information:</strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p><strong>追加情報:</strong></p>\n\n<p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - VO001000KWJSE, VO002000KWJSF, VO004000KWJSH, VT004000KWJSU, MO001600KWJSN and MO003200KWJSQ  Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - VO001000KWJSE、VO002000KWJSF、VO004000KWJSH、VT004000KWJSU、MO001600KWJSN、およびMO003200KWJSQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MO003200KWJSQ","target_guid":"4d2340a5-304f-3330-3230-304b574a5351","type":"nvme"},{"id":"VO002000KWJSF","target_guid":"562340a5-304f-3230-3030-304b574a5346","type":"nvme"},{"id":"MO001600KWJSN","target_guid":"4d2340a5-304f-3130-3630-304b574a534e","type":"nvme"},{"id":"VO001000KWJSE","target_guid":"562340a5-304f-3130-3030-304b574a5345","type":"nvme"},{"id":"VT004000KWJSU","target_guid":"562340a5-3054-3430-3030-304b574a5355","type":"nvme"},{"id":"VO004000KWJSH","target_guid":"562340a5-304f-3430-3030-304b574a5348","type":"nvme"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T05:55:43","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>This firmware corrects the potential for a drive to become disabled and nonfunctional during certain conditions or workloads.</li>\n\t<li>After the drive is upgraded to firmware version HPK1, it cannot be downgraded to firmware version HPK0.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This firmware corrects the potential for a drive to become disabled and nonfunctional during certain conditions or workloads.</li>\n\t<li>After the drive is upgraded to firmware version HPK1, it cannot be downgraded to firmware version HPK0.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO001000KWJSE","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO002000KWJSF","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO001600KWJSN","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO004000KWJSH","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO003200KWJSQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VT004000KWJSU","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains be2net drivers for the HPE Blade Emulex 10/20GbE Server Adapters running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Blade Emulex 10/20GbE サーバーアダプター用のbe2net ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"105347","datemodified":"2021-03-08T20:12:29","file_list":["./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/be2net","./lib/modules/5.3.18-22-default/updates/be2net/be2net.ko","./usr/share/smartupdate/be2net_bl-kmp-default/component.xml"],"md5sum":"beea0c660636fe82866a1376e594c8b8","name":"be2net_bl-kmp-default-12.0.1342.0_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-03-08T20:04:05","revision":"0","sha1sum":"ae7b8285c1e582c955645fbd589f6604ec304971","size":"102KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec77a8ea21"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"106974","datemodified":"2021-03-08T20:16:35","file_list":["./lib/modules/4.12.14-195-default","./lib/modules/4.12.14-195-default/updates","./lib/modules/4.12.14-195-default/updates/be2net","./lib/modules/4.12.14-195-default/updates/be2net/be2net.ko","./usr/share/smartupdate/be2net_bl-kmp-default/component.xml"],"md5sum":"76dac42c67bd014951471f0991bc9b0f","name":"be2net_bl-kmp-default-12.0.1342.0_k4.12.14_195-1.sles15sp1.x86_64.rpm","release":"2021-03-08T20:04:05","revision":"0","sha1sum":"a30cc46dbf6538d0dd24d2386e0e1b1ec89c475d","size":"104KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec77a8ea21"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"e7f36bf9643a4e489310dc38c624a57b","version":"1a5ab721a91746cda8d949d335f821dd"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE Blade Emulex 10/20GbEドライバー for SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0728","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c1935","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c1934","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-03-19T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>These drivers have been&nbsp;updated to maintain compatibility with the latest firmware.</p>\n","latest_fixes_x_late":"<p>These drivers have been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 15 SP2.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"be2net_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2net_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2net_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2net_bl-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900374","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware and boot BIOS of Emulex Fibre Channel host bus adapters."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"6543816","datemodified":"2021-08-27T09:05:59","file_list":["cp049105.xml","cpqsetup.exe","elxflashStandalone-windows-12.8.352.12-1/boot/","elxflashStandalone-windows-12.8.352.12-1/boot/UU1280A3.PRG","elxflashStandalone-windows-12.8.352.12-1/firmware/","elxflashStandalone-windows-12.8.352.12-1/firmware/A12835212.grp","elxflashStandalone-windows-12.8.352.12-1/firmware/B12835212.grp","elxflashStandalone-windows-12.8.352.12-1/firmware/P12835212.grp","elxflashStandalone-windows-12.8.352.12-1/firmware/UD210X6.ALL","elxflashStandalone-windows-12.8.352.12-1/win/","elxflashStandalone-windows-12.8.352.12-1/win/elxflash.bat","elxflashStandalone-windows-12.8.352.12-1/win/winlpcfg.bat","elxflashStandalone-windows-12.8.352.12-1/win/x64/","elxflashStandalone-windows-12.8.352.12-1/win/x64/boot/","elxflashStandalone-windows-12.8.352.12-1/win/x64/elxflash.exe","elxflashStandalone-windows-12.8.352.12-1/win/x64/ElxLpCfgSvcMsg.dll","elxflashStandalone-windows-12.8.352.12-1/win/x64/firmware/","elxflashStandalone-windows-12.8.352.12-1/win/x64/fwmatrix.txt","elxflashStandalone-windows-12.8.352.12-1/win/x64/libdfc.dll","elxflashStandalone-windows-12.8.352.12-1/win/x64/RM.INI","elxflashStandalone-windows-12.8.352.12-1/win/x64/WinLpCfg.exe","fwmatrix.txt","hpe_fw_matrix.xml","installer.dll","payload.json","readme.txt","elxflashStandalone-windows-12.8.352.12-1/win/x64/readme.txt","reference.xml"],"md5sum":"0a6a37c9279f4d742a1b51a063464a25","name":"cp049105.exe","release":"2021-08-27T08:51:21","revision":"0","sha1sum":"1a6fc7966aa846371f68b709d7827dff18fac362","size":"6MB","target_guids":[],"type_of_change":"1","version":"2021.10.01"}],"id":{"product":"f82a8e7c3d364abdbfbca3044980539d","version":"6e6617d0634d480bb0bbb6e470b2859d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory.<br />\nThe downloaded file is a self-extracting executable with a filename based on the Component Number.<br />\nFrom that drive and directory, execute the downloaded file.<br />\n<br />\nClick the &quot;Install&quot; button to proceed with the installation.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Fibre Channel Host Bus Adapters for Microsoft Windows Server 2012R2 x64"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-23T05:53:19","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Adapter</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Speed</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Universal Boot Image</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Firmware</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>UEFI</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Boot Bios</strong></p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE 81E 8Gb Single Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.80a3</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">2.10X6</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.183.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.9.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE 82E 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.80a3</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">2.10X6</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.183.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.9.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE 84E 8Gb Quad Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.80a3</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">2.10X6</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.183.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.9.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1000E 16Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1000E 16Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100E 16Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100E 16Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100E Quad Port 16Gb Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"emulex","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for the HPE Blade Emulex 10/20GbE Server Adapters for Windows Server 2016."},{"lang":"ja","x_late":"このコンポーネントパッケージは、HPE Blade Emulex 10/20GbEサーバーアダプタードライバー for Windows Server 2016が含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1607040","datemodified":"2021-07-21T19:27:07","file_list":["bepnic.dll","bepnic.rtf","cp045173.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll","occfg.exe","ocnd65.cat","ocnd65.inf","ocnd65.sys"],"md5sum":"ee0c489989fb8c80032aa73e04a0daee","name":"cp045173.exe","release":"2021-07-21T19:13:06","revision":"0","sha1sum":"ee7530c0102fa39511fed97f8c11ad5704b87459","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfe4a13f6"],"type_of_change":"0","version":"12.0.1344.0"}],"id":{"product":"950aa10923d94fe39adbfe18fa1f4f69","version":"cb83568273b94c7ab80ecf9d976c3b4f"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE Driver for Windows Server 2016"},{"lang":"ja","x_late":"HPE Blade Emulex 10/20GbEドライバーfor Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"0728","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c1935","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c1934","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-03T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This driver addresses a Windows Stop Error (BSOD) seen after Windows Event ID 67.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"ocnd65.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO002000KWVVC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3230-3030-304b57565643","Version":"4ICRHPK3"},{"DeviceName":"VO004000KWVUR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3430-3030-304b57565552","Version":"4ICRHPK3"},{"DeviceName":"MO001600KWVUU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b57565555","Version":"4ICRHPK3"},{"DeviceName":"MO003200KWVUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b57565556","Version":"4ICRHPK3"},{"DeviceName":"MO006400KWVVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b57565641","Version":"4ICRHPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO002000KWVVC、VO004000KWVUR、MO001600KWVUU、MO003200KWVUV、およびMO006400KWVVA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for VMware ESXi - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;4ICRHPK3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:&nbsp;</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to 4ICRHPK3 that may result in SSD failure starting at 4,700 hours of operation, neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us\" style=\"color:blue; text-decoration:underline\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us</a></li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16682127","datemodified":"2021-08-27T08:58:27","file_list":["/CP048511_BUILD_2.data","/CP048511.vmexe","/CP048511.vmexe64","/CP048511.vmfile","/CP048511_VMw.zip","/CP048511.xml","/payload.json","/CP048511_VMw.zip/index.xml","/CP048511_VMw.zip/vendor-index.xml","/CP048511_VMw.zip/metadata.zip","/CP048511_VMw.zip/vib20/CP048511/HPE_bootbank_CP048511_4ICRHPK3.2-7.0.0.15843807.vib","/CP048511_VMw.zip/metadata.zip/vendor-index.xml","/CP048511_VMw.zip/metadata.zip/vmware.xml","/CP048511_VMw.zip/metadata.zip/vibs/CP048511-6164370636035978595.xml","/CP048511_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048511_4ICRHPK3.2-7.0.0.15843807.xml"],"md5sum":"d320362140829da7a4d3689651ea81e5","name":"CP048511.zip","release":"2021-08-27T08:53:27","revision":"0","sha1sum":"d3efbe7088543cd73451afc93967097317cad7ce","size":"15MB","target_guids":["562340a5-304f-3230-3030-304b57565643","562340a5-304f-3430-3030-304b57565552","4d2340a5-304f-3130-3630-304b57565555","4d2340a5-304f-3330-3230-304b57565556","4d2340a5-304f-3630-3430-304b57565641"],"type_of_change":"2","version":"4ICRHPK3","vib_list":[{"name":"CP048511","version":"4ICRHPK3.2-7.0.0.15843807"}]}],"id":{"product":"a5e366733eda432d8665f3d8aaa40d56","version":"68760c8a1e514d1c8c960ebadb663b56"},"installation":{"command":"CP042960.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - VO002000KWVVC、VO004000KWVUR、MO001600KWVUU、MO003200KWVUV、およびMO006400KWVVAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MO006400KWVVA","target_guid":"4d2340a5-304f-3630-3430-304b57565641","type":"nvme"},{"id":"VO004000KWVUR","target_guid":"562340a5-304f-3430-3030-304b57565552","type":"nvme"},{"id":"MO003200KWVUV","target_guid":"4d2340a5-304f-3330-3230-304b57565556","type":"nvme"},{"id":"VO002000KWVVC","target_guid":"562340a5-304f-3230-3030-304b57565643","type":"nvme"},{"id":"MO001600KWVUU","target_guid":"4d2340a5-304f-3130-3630-304b57565555","type":"nvme"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T09:11:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Fixed issues described in Customer Bulletin at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111900en_us.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to 4ICRHPK3 that may result in SSD failure starting at 4,700 hours of operation, neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us\" style=\"color:blue; text-decoration:underline\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MO001600KWVUU","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO002000KWVVC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO004000KWVUR","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO006400KWVVA","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO003200KWVUV","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000800JXBEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a58424556","Version":"HPD1"},{"DeviceName":"MO001600JXBFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a58424650","Version":"HPD1"},{"DeviceName":"MO003200JXBFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a58424651","Version":"HPD1"},{"DeviceName":"MO006400JXBFR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a58424652","Version":"HPD1"},{"DeviceName":"MO000960JXBFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3936-304a58424641","Version":"HPD1"},{"DeviceName":"MO001920JXBFT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a58424654","Version":"HPD1"},{"DeviceName":"MO003840JXBFU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3834-304a58424655","Version":"HPD1"},{"DeviceName":"MO007680JXBGA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3730-3638-304a58424741","Version":"HPD1"},{"DeviceName":"MO015360JXBFV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3531-3336-304a58424656","Version":"HPD1"},{"DeviceName":"EO000400JXBEU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304a58424555","Version":"HPD1"},{"DeviceName":"EO000800JXBFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304a5842464c","Version":"HPD1"},{"DeviceName":"EO001600JXBFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-304a5842464e","Version":"HPD1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MO000800JXBEV、MO001600JXBFP、MO003200JXBFQ、MO006400JXBFR、MO000960JXBFA、MO001920JXBFT、MO003840JXBFU、MO007680JXBGA、MO015360JXBFV、EO000400JXBEU、EO000800JXBFL およびEO001600JXBFN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5272927","datemodified":"2021-07-27T13:03:47","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD1-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD1-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD1-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD1-2.1/CP049153.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD1-2.1/HBCQSssseFD1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD1-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD1-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD1-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD1-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049153.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049153.scexe"],"md5sum":"f4981fad7c37ba7ff747fad97e234fd5","name":"firmware-hdd-24384980ec-HPD1-2.1.x86_64.rpm","release":"2021-07-27T12:52:08","revision":"0","sha1sum":"517aa7b2325083bbf0b68eb88177a9f88efc544a","size":"5MB","target_guids":["4d2340a5-304f-3030-3830-304a58424556","4d2340a5-304f-3130-3630-304a58424650","4d2340a5-304f-3330-3230-304a58424651","4d2340a5-304f-3630-3430-304a58424652","4d2340a5-304f-3030-3936-304a58424641","4d2340a5-304f-3130-3932-304a58424654","4d2340a5-304f-3330-3834-304a58424655","4d2340a5-304f-3730-3638-304a58424741","4d2340a5-304f-3531-3336-304a58424656","452340a5-304f-3030-3430-304a58424555","452340a5-304f-3030-3830-304a5842464c","452340a5-304f-3130-3630-304a5842464e"],"type_of_change":"1","version":"HPD1"}],"id":{"product":"8d0bd1ce26004a9e8191551757cba42d","version":"f672bc23441f4266b6128820bc0970ee"},"installation":{"command":"CP040307.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux（x64）- MO000800JXBEV、MO001600JXBFP、MO003200JXBFQ、MO006400JXBFR、MO000960JXBFA、MO001920JXBFT、MO003840JXBFU、MO007680JXBGA、MO015360JXBFV、EO000400JXBEU、EO000800JXBFLおよびEO001600JXBFNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MO000800JXBEV","target_guid":"4d2340a5-304f-3030-3830-304a58424556","type":"sas"},{"id":"MO001600JXBFP","target_guid":"4d2340a5-304f-3130-3630-304a58424650","type":"sas"},{"id":"MO003200JXBFQ","target_guid":"4d2340a5-304f-3330-3230-304a58424651","type":"sas"},{"id":"MO006400JXBFR","target_guid":"4d2340a5-304f-3630-3430-304a58424652","type":"sas"},{"id":"MO000960JXBFA","target_guid":"4d2340a5-304f-3030-3936-304a58424641","type":"sas"},{"id":"MO001920JXBFT","target_guid":"4d2340a5-304f-3130-3932-304a58424654","type":"sas"},{"id":"MO003840JXBFU","target_guid":"4d2340a5-304f-3330-3834-304a58424655","type":"sas"},{"id":"MO007680JXBGA","target_guid":"4d2340a5-304f-3730-3638-304a58424741","type":"sas"},{"id":"MO015360JXBFV","target_guid":"4d2340a5-304f-3531-3336-304a58424656","type":"sas"},{"id":"EO000400JXBEU","target_guid":"452340a5-304f-3030-3430-304a58424555","type":"sas"},{"id":"EO000800JXBFL","target_guid":"452340a5-304f-3030-3830-304a5842464c","type":"sas"},{"id":"EO001600JXBFN","target_guid":"452340a5-304f-3130-3630-304a5842464e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-27T12:49:29","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;. Support for second source PMIC from IDT.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MO001920JXBFT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000400JXBEU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800JXBEV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003840JXBFU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200JXBFQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO015360JXBFV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO001600JXBFN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600JXBFP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000960JXBFA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO007680JXBGA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000800JXBFL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO006400JXBFR","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWWQB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a57575142","Version":"HPD6"},{"DeviceName":"MB002000JWWQA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a57575141","Version":"HPD6"},{"DeviceName":"MB001000JWWPV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304a57575056","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB004000JWWQB, MB002000JWWQA and MB001000JWWPV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB004000JWWQB, MB002000JWWQA and MB001000JWWPV Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD4</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp; &nbsp;&nbsp; None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"18087435","datemodified":"2021-08-27T12:01:32","file_list":["/CP048431_BUILD_2.data","/CP048431.vmexe","/CP048431.vmexe64","/CP048431.vmfile","/CP048431_VMw.zip","/CP048431.xml","/payload.json","/CP048431_VMw.zip/index.xml","/CP048431_VMw.zip/vendor-index.xml","/CP048431_VMw.zip/metadata.zip","/CP048431_VMw.zip/vib20/CP048431/HPE_bootbank_CP048431_HPD6.2-7.0.0.15843807.vib","/CP048431_VMw.zip/metadata.zip/vendor-index.xml","/CP048431_VMw.zip/metadata.zip/vmware.xml","/CP048431_VMw.zip/metadata.zip/vibs/CP048431-8751542515098303286.xml","/CP048431_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048431_HPD6.2-7.0.0.15843807.xml"],"md5sum":"2fce5512ec5d8b51ac9f4b1c1b07a43b","name":"CP048431.zip","release":"2021-08-27T11:56:41","revision":"0","sha1sum":"1bc22304a8caa8e90df10b7e56199a7b61e77ea5","size":"17MB","target_guids":["4d2340a5-3042-3430-3030-304a57575142","4d2340a5-3042-3230-3030-304a57575141","4d2340a5-3042-3130-3030-304a57575056"],"type_of_change":"1","version":"HPD6","vib_list":[{"name":"CP048431","version":"HPD6.2-7.0.0.15843807"}]}],"id":{"product":"b1381f6ec67b40269898593ac27aca95","version":"d2efdafe96924d7ab40eb718466b95a9"},"installation":{"command":"CP043266.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p><strong>Additional information to execute VIB file.</strong></p>\n\n<p><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/hp/swpackagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>HP Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加します。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします</li>\n\t<li>CPXXXXXX.vmexe(ESXi 6.7 &以前のバージョン)およびCPXXXXXX.vmexe64(ESXi 7.0)は、次のコマンドを使用して実行可能です:</li>\n</ul>\n\n<p>             chmod x CPXXXXXX.vmexe    または    chmod x CPXXXXXX.vmexe64</p>\n\n<ul>\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例：./CPXXXXXX.vmexe(または)./CPXXXXXX.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul>\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります:rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul>\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります:rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB004000JWWQB, MB002000JWWQA and MB001000JWWPV Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB004000JWWQB、MB002000JWWQA、およびMB001000JWWPVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB004000JWWQB","target_guid":"4d2340a5-3042-3430-3030-304a57575142","type":"sas"},{"id":"MB002000JWWQA","target_guid":"4d2340a5-3042-3230-3030-304a57575141","type":"sas"},{"id":"MB001000JWWPV","target_guid":"4d2340a5-3042-3130-3030-304a57575056","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-10T09:00:34","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB002000JWWQA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB001000JWWPV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB004000JWWQB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VS000480KWDUP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannmK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3030-3438-304b57445550","Version":"HPK4"},{"DeviceName":"VS000960KWDUQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannmK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3030-3936-304b57445551","Version":"HPK4"},{"DeviceName":"MS000400KWDUR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannmK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3053-3030-3430-304b57445552","Version":"HPK4"},{"DeviceName":"MS000800KWDUT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannmK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3053-3030-3830-304b57445554","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VS000480KWDUP, VS000960KWDUQ, MS000400KWDUR and MS000800KWDUT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for VMware ESXi -&nbsp;VS000480KWDUP, VS000960KWDUQ, MS000400KWDUR&nbsp;and MS000800KWDUT Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"20153731","datemodified":"2021-08-26T10:29:40","file_list":["/CP048484_BUILD_2.data","/CP048484.vmexe","/CP048484.vmexe64","/CP048484.vmfile","/CP048484_VMw.zip","/CP048484.xml","/payload.json","/CP048484_VMw.zip/index.xml","/CP048484_VMw.zip/vendor-index.xml","/CP048484_VMw.zip/metadata.zip","/CP048484_VMw.zip/vib20/CP048484/HPE_bootbank_CP048484_HPK4.2-7.0.0.15843807.vib","/CP048484_VMw.zip/metadata.zip/vendor-index.xml","/CP048484_VMw.zip/metadata.zip/vmware.xml","/CP048484_VMw.zip/metadata.zip/vibs/CP048484--2066392048896532665.xml","/CP048484_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048484_HPK4.2-7.0.0.15843807.xml"],"md5sum":"c324fbd05489d0c8f308bc6d41fc4f17","name":"CP048484.zip","release":"2021-08-26T10:24:27","revision":"0","sha1sum":"2cb1888d16c4cc28b5c82c741aa67729319e73c2","size":"19MB","target_guids":["562340a5-3053-3030-3438-304b57445550","562340a5-3053-3030-3936-304b57445551","4d2340a5-3053-3030-3430-304b57445552","4d2340a5-3053-3030-3830-304b57445554"],"type_of_change":"1","version":"HPK4","vib_list":[{"name":"CP048484","version":"HPK4.2-7.0.0.15843807"}]}],"id":{"product":"496a47bbdbd9415dbba6770e6ba0409b","version":"b0c7c9755a554a80a6da33cf6687893c"},"installation":{"command":"CP040921.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi  - VS000480KWDUP, VS000960KWDUQ, MS000400KWDUR and MS000800KWDUT Drives"},{"lang":"ja","x_late":"VMware ESXi用オンラインNVMe SSDフラッシュコンポーネント - VS000480KWDUP、VS000960KWDUQ、MS000400KWDUR、およびMS000800KWDUTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MS000400KWDUR","target_guid":"4d2340a5-3053-3030-3430-304b57445552","type":"nvme"},{"id":"VS000960KWDUQ","target_guid":"562340a5-3053-3030-3936-304b57445551","type":"nvme"},{"id":"MS000800KWDUT","target_guid":"4d2340a5-3053-3030-3830-304b57445554","type":"nvme"},{"id":"VS000480KWDUP","target_guid":"562340a5-3053-3030-3438-304b57445550","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-14T07:39:22","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MS000800KWDUT","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MS000400KWDUR","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VS000480KWDUP","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VS000960KWDUQ","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800026","languages":[{"lang":"tw","x_late":"軟體 - 管理"},{"lang":"en","x_late":"Software - Management"},{"lang":"ko","x_late":"소프트웨어 - 관리"},{"lang":"ja","x_late":"ソフトウェア - マネジメント"},{"lang":"cn","x_late":"软件 - 管理"}]}],"description":[{"lang":"en","x_late":"The HPE ESXi Management Smart Component for ESXi 6.5 includes the latest HPE Common Information Model (CIM) Providers, HPE Integrated Lights-Out (iLO) driver, HPE Compaq ROM Utility (CRU) driver, the HPE Agentless Management Service (AMS), and Fibre Channel(FC) HBA access libraries. \n "},{"lang":"ja","x_late":"HPE ESXiマネジメントSmartコンポーネントfor VMware ESXi 6.5には、最新のHPE Common Information Model (CIM) Provider、HPE Integrated Lights-Out (iLO)ドライバー、HPE Compaq ROM Utility (CRU)ドライバー、HPE Agentless Management Service (AMS)、およびファイバーチャネル (FC) HBAアクセスライブラリが含まれています。\n "}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"13823066","datemodified":"2021-09-07T18:42:22","file_list":["/cp049077.xml","/esxi6.5uX-mgmt-bundle-gen9.3.8.0.12-1.zip","/esxi6.5uX-mgmt-bundle-gen9.3.8.0.12-1.zip/index.xml","/esxi6.5uX-mgmt-bundle-gen9.3.8.0.12-1.zip/vendor-index.xml","/esxi6.5uX-mgmt-bundle-gen9.3.8.0.12-1.zip/metadata-esxi6.5uX-mgmt-bundle-gen9.3.8.0.12-1.zip","/esxi6.5uX-mgmt-bundle-gen9.3.8.0.12-1.zip/amshelpr-650.11.8.0.8-1.4240417.vib","/esxi6.5uX-mgmt-bundle-gen9.3.8.0.12-1.zip/smx-provider-650.03.16.00.4-4240417.vib","/esxi6.5uX-mgmt-bundle-gen9.3.8.0.12-1.zip/fc-enablement-650.3.8.0.6-4240417.vib","/esxi6.5uX-mgmt-bundle-gen9.3.8.0.12-1.zip/ilo_650.10.7.5.2-1OEM.650.0.0.4240417.vib","/esxi6.5uX-mgmt-bundle-gen9.3.8.0.12-1.zip/cru_650.6.5.10.4-1OEM.650.0.0.4240417.vib","/esxi6.5uX-mgmt-bundle-gen9.3.8.0.12-1.zip/metadata-esxi6.5uX-mgmt-bundle-gen9.3.8.0.12-1.zip/vendor-index.xml","/esxi6.5uX-mgmt-bundle-gen9.3.8.0.12-1.zip/metadata-esxi6.5uX-mgmt-bundle-gen9.3.8.0.12-1.zip/vmware.xml","/esxi6.5uX-mgmt-bundle-gen9.3.8.0.12-1.zip/metadata-esxi6.5uX-mgmt-bundle-gen9.3.8.0.12-1.zip/vibs/amshelpr-7710093742773707945.xml","/esxi6.5uX-mgmt-bundle-gen9.3.8.0.12-1.zip/metadata-esxi6.5uX-mgmt-bundle-gen9.3.8.0.12-1.zip/vibs/smx-provider--7066341665308296940.xml","/esxi6.5uX-mgmt-bundle-gen9.3.8.0.12-1.zip/metadata-esxi6.5uX-mgmt-bundle-gen9.3.8.0.12-1.zip/vibs/ilo-5995240362405261046.xml","/esxi6.5uX-mgmt-bundle-gen9.3.8.0.12-1.zip/metadata-esxi6.5uX-mgmt-bundle-gen9.3.8.0.12-1.zip/vibs/fc-enablement--2881805892426985186.xml","/esxi6.5uX-mgmt-bundle-gen9.3.8.0.12-1.zip/metadata-esxi6.5uX-mgmt-bundle-gen9.3.8.0.12-1.zip/vibs/cru-6087260586819000143.xml","/esxi6.5uX-mgmt-bundle-gen9.3.8.0.12-1.zip/metadata-esxi6.5uX-mgmt-bundle-gen9.3.8.0.12-1.zip/bulletins/esxi6.5uX-mgmt-bundle-gen9.3.8.0.12-1.xml"],"md5sum":"9a047786e78ac120e8161c27557d5f05","name":"cp049077.zip","release":"2021-09-07T18:38:16","revision":"0","sha1sum":"8ab406838a751f93fc13f6f0593f98b68ddfacb1","size":"13MB","target_guids":[],"type_of_change":"1","version":"2021.10.00","vib_list":[{"name":"amshelpr","version":"650.11.8.0.8-1.4240417"},{"name":"smx-provider","version":"650.03.16.00.4-4240417"},{"name":"ilo","version":"650.10.7.5.2-1OEM.650.0.0.4240417"},{"name":"fc-enablement","version":"650.3.8.0.6-4240417"},{"name":"cru","version":"650.6.5.10.4-1OEM.650.0.0.4240417"}]}],"id":{"product":"955509238bc94896999b8a9beb96f9dc","version":"e49346ce7f2d424ea4674231db18adf4"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To&nbsp;remotely install&nbsp;this&nbsp;bundle&nbsp; online using the HP Smart Update Manager (HPSUM) from the HP Service Pack for ProLiant (SPP):</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"http://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=8788688&amp;lang=en&amp;cc=us\">HP USB Key Creator Utility</a>.</li>\n\t<li>Copy&nbsp;this driver component&nbsp;to the directory<em> /SPP20xxxxx/hp/swpackages</em> on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.</li>\n\t<li>Change directories to <em>/hp/swpackages</em> and execute&nbsp;./hpsum.</li>\n\t<li>Select the &quot;next&quot; button.</li>\n\t<li>Click &quot;Add Single Target.&quot;</li>\n\t<li>Enter&nbsp;the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow HP Smart Update Manager&nbsp;instructions&nbsp;to complete the driver update.</li>\n</ol>\n\n<p><br />\n<strong>To&nbsp;install this bundle using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the component zip file to extract the driver offline bundle.</li>\n\t<li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li>\n</ol>\n\n<p>Refer to VMware documentation for information on the esxcli commands</p>\n"},{"lang":"ja","x_late":"<p><strong>HP Service Pack for ProLiant (SPP)からHP Smart Update Manager (HPSUM)を使用して、このバンドルをオンラインでリモートインストールするには：</strong></p>\n\n<ol>\n\t<li><a href=\"http://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=8788688&lang=en&cc=us\">HP USB Key Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>このドライバーコンポーネントをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。</li>\n\t<li><em>/hp/swpackages</em>にディレクトリを変更し、./hpsumを実行します。</li>\n\t<li>「次へ」ボタンを選択します。</li>\n\t<li>「シングルターゲットの追加」をクリックします。</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>HP Smart Update Manager 手順に従って、ドライバーアップデートを完了します。</li>\n</ol>\n\n<p><br />\n<strong>VMwareツールを使用して、このバンドルをインストールするには：</strong></p>\n\n<ol>\n\t<li>ドライバーオフラインバンドルを抽出するために、このコンポーネントのzipファイルを解凍します。</li>\n\t<li>オフラインバンドルをインストールするには、「esxcli」コマンドを実行します。</li>\n</ol>\n\n<p>esxcliコマンドの詳細については、VMwareのドキュメントを参照してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Management Bundle Smart Component for ESXi 6.5 for Gen9 Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-10-18T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Agentless Management Service</strong></p>\n\n<ul>\n\t<li>Added support for new NIC devices (Gen10 AMS only)</li>\n\t<li>Added support for new&nbsp;SATA, SAS and NVMe drives (Gen10 AMS only)</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Agentless Management Service</strong></p>\n\n<ul>\n\t<li>Reduce&nbsp;Software Inventory cache refresh time to 15 seconds to help resolve OneView online SW update issues without reboot.</li>\n\t<li>Fixed resource leak when AHS logging fails</li>\n\t<li>Fix incorrect reporting of SATA disks attached to Smart Array and SAS controllers in the&nbsp;cpqIdeAtaDisk MIB.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Agentless Management Service</strong></p>\n\n<ul>\n\t<li>Applied fixes to net-snmp open source code for CVE-2018-18065, CVE-2018-18066, CVE-2015-5621</li>\n</ul>\n\n<p><strong>iLO Driver</strong></p>\n\n<ul>\n\t<li>Fixed driver unload function to allow controller to function properly on reload.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"H05","value":"HPE ProLiant m510 Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"H07","value":"HPE ProLiant m710x Server Blade"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"}],"sw_keys":[{"name":"cru:650.6.5.10.4-1OEM.650.0.0.4240417","sw_key_expectedpath":"driver:vmware:zip"},{"name":"ilo:650.10.7.5.2-1OEM.650.0.0.4240417","sw_key_expectedpath":"driver:vmware:zip"},{"name":"amshelpr:650.11.8.0.8-1.4240417","sw_key_expectedpath":"software:vmware:zip"},{"name":"smx-provider:650.03.16.00.4-4240417","sw_key_expectedpath":"software:vmware:zip"},{"name":"fc-enablement:650.3.8.0.6-4240417","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This package updates the I/O module firmware on HPE D6020 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"16877178","datemodified":"2021-07-06T09:03:58","file_list":["/CP048699_BUILD_5.data","/CP048699.vmcfg","/CP048699.vmexe","/CP048699.vmexe64","/CP048699.vmfile","/CP048699_VMw.zip","/CP048699.xml","/payload.json","/CP048699_VMw.zip/index.xml","/CP048699_VMw.zip/vendor-index.xml","/CP048699_VMw.zip/metadata.zip","/CP048699_VMw.zip/vib20/CP048699/HPE_bootbank_CP048699_2.74.5-7.0.0.15525992.vib","/CP048699_VMw.zip/metadata.zip/vendor-index.xml","/CP048699_VMw.zip/metadata.zip/vmware.xml","/CP048699_VMw.zip/metadata.zip/vibs/CP048699-6639426429102405178.xml","/CP048699_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048699_2.74.5-7.0.0.15525992.xml"],"md5sum":"0642f3fd6353287fb7e9519439b51867","name":"CP048699.zip","release":"2021-07-06T08:58:04","revision":"0","sha1sum":"fdc960e7318ef9b4e56cda3374a89353e825fd13","size":"16MB","target_guids":[],"type_of_change":"1","version":"2.74","vib_list":[{"name":"CP048699","version":"2.74.5-7.0.0.15525992"}]}],"id":{"product":"7339a71cb6e2439ab77a0b21ff9be17e","version":"87d8e337583e40979b72fd1816009edb"},"installation":{"command":"setup","command_params":"-t D6020 -v 2.74 -i Tormore-Release-2.74-build-001.bin -l D6020.log","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":720,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>VMWare Smart Component Installation Instructions:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root (You must be root in order to apply the ROM update).</li>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Unzip the Smart Component with unzip CP0xxxxx.zip command.</li>\n\t<li>From the same directory, execute the Smart Component. For example: ./CP0xxxxx.vmexe.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p><strong>NOTES:</strong></p>\n\n<p>OPTIONS for in band enclosure flash</p>\n\n<table border=\"0\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>-d, --discover &lt;absolute path to file&gt;</td>\n\t\t\t<td>Dumps discovery information in XML format to &lt;file&gt;</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-e, --reflash</td>\n\t\t\t<td>Flash even if the device is already up to date</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-f, &nbsp;--force</td>\n\t\t\t<td>Always flash applicable devices (same as -e -g)</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-g, --downgrade</td>\n\t\t\t<td>Flash if the device has a later firmware</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-s, --silent</td>\n\t\t\t<td>Do not display any text and no user interaction required</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;</p>\n\n<p><strong>Remote Online:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li>\n\t<li>Run the launch_sum.bat in the root of the ISO.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v191364/D6020_v2.74I.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component for VMware (ESXi)"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"id":"D6020","target_guid":"","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-17T13:22:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p>\n\n<ul>\n\t<li>Temperature sensors logic inside gSEP model and SES database</li>\n\t<li>When an IOM is pulled the surviving IOM reports false critical temperatures</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v191364/D6020_v2.74I.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"}],"sw_keys":[{"name":"D6020","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GWTFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG07abHPG7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304757544645","Version":"HPG7"},{"DeviceName":"MB014000GWTFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG07abHPG7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304757544646","Version":"HPG7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB012000GWTFE and MB014000GWTFF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB012000GWTFE and MB014000GWTFF Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp; &nbsp; &nbsp;</strong>HPG7</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG6</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG6<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"16275499","datemodified":"2021-08-26T14:12:34","file_list":["/CP048336_BUILD_2.data","/CP048336.vmexe","/CP048336.vmexe64","/CP048336.vmfile","/CP048336_VMw.zip","/CP048336.xml","/payload.json","/CP048336_VMw.zip/index.xml","/CP048336_VMw.zip/vendor-index.xml","/CP048336_VMw.zip/metadata.zip","/CP048336_VMw.zip/vib20/CP048336/HPE_bootbank_CP048336_HPG7.2-7.0.0.15843807.vib","/CP048336_VMw.zip/metadata.zip/vendor-index.xml","/CP048336_VMw.zip/metadata.zip/vmware.xml","/CP048336_VMw.zip/metadata.zip/vibs/CP048336-8581921282004777982.xml","/CP048336_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048336_HPG7.2-7.0.0.15843807.xml"],"md5sum":"ddccbdf304ecb51c6edddb7baf879905","name":"CP048336.zip","release":"2021-08-26T14:07:16","revision":"0","sha1sum":"602d52518dec62ddc4f5407c446c16629d1d20dc","size":"15MB","target_guids":["4d2340a5-3042-3231-3030-304757544645","4d2340a5-3042-3431-3030-304757544646"],"type_of_change":"1","version":"HPG7","vib_list":[{"name":"CP048336","version":"HPG7.2-7.0.0.15843807"}]}],"id":{"product":"e6ce1a91bd5b4f829c98f53210189206","version":"61934bc349d348f4bc2d986d9beab645"},"installation":{"command":"CP042459.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB012000GWTFE and MB014000GWTFF Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB012000GWTFEおよびMB014000GWTFFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB014000GWTFF","target_guid":"4d2340a5-3042-3431-3030-304757544646","type":"sata"},{"id":"MB012000GWTFE","target_guid":"4d2340a5-3042-3231-3030-304757544645","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-05T20:38:39","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB012000GWTFE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB014000GWTFF","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000300JWBHR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SEnD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57424852","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: EG000300JWBHR"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG000300JWBHR&nbsp;Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"4887052","datemodified":"2021-07-23T08:39:44","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-2e4c61fc63-HPD5-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e4c61fc63-HPD5-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e4c61fc63-HPD5-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e4c61fc63-HPD5-2.1/CP048055.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e4c61fc63-HPD5-2.1/T14SEnD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e4c61fc63-HPD5-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e4c61fc63-HPD5-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e4c61fc63-HPD5-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e4c61fc63-HPD5-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048055.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048055.scexe"],"md5sum":"dd17010309da23ad3e0695b0c11c7e22","name":"firmware-hdd-2e4c61fc63-HPD5-2.1.x86_64.rpm","release":"2021-07-23T08:27:05","revision":"0","sha1sum":"997b19ccfbe346b4e25801d007ae819749c42cc0","size":"4MB","target_guids":["452340a5-3047-3030-3330-304a57424852"],"type_of_change":"1","version":"HPD5"}],"id":{"product":"57c8ff295b854dbeaea4e204fed3ef83","version":"d0174a2937734bf79e3b7732622d4eff"},"installation":{"command":"CP040299.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64)  - EG000300JWBHR Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - EG000300JWBHRドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EG000300JWBHR","target_guid":"452340a5-3047-3030-3330-304a57424852","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-21T05:56:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>A low-probability, high severity corner case of sustained outer-diameter activity with emergency power off when heads are at the outer diameter prevented heads from parking/latching properly on a few drives in the field.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG000300JWBHR","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000JEXYA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRESD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a45585941","Version":"HPD9"},{"DeviceName":"MB6000JEXYB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRESD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a45585942","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB4000JEXYA and MB6000JEXYB"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MB4000JEXYAおよびMB6000JEXYB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB4000JEXYA and MB6000JEXYB Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD8</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None.</p>\n\n<p>&nbsp;<strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"16233342","datemodified":"2021-08-26T20:10:14","file_list":["/CP048369_BUILD_2.data","/CP048369.vmexe","/CP048369.vmexe64","/CP048369.vmfile","/CP048369_VMw.zip","/CP048369.xml","/payload.json","/CP048369_VMw.zip/index.xml","/CP048369_VMw.zip/vendor-index.xml","/CP048369_VMw.zip/metadata.zip","/CP048369_VMw.zip/vib20/CP048369/HPE_bootbank_CP048369_HPD9.2-7.0.0.15843807.vib","/CP048369_VMw.zip/metadata.zip/vendor-index.xml","/CP048369_VMw.zip/metadata.zip/vmware.xml","/CP048369_VMw.zip/metadata.zip/vibs/CP048369-7910780000386806495.xml","/CP048369_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048369_HPD9.2-7.0.0.15843807.xml"],"md5sum":"d4996d54dc6545f9cda75c0d9df4ddf8","name":"CP048369.zip","release":"2021-08-26T20:05:19","revision":"0","sha1sum":"35f223d77db3b3feffad771cc13974160b1679b0","size":"15MB","target_guids":["002340a5-4d00-3442-3030-304a45585941","002340a5-4d00-3642-3030-304a45585942"],"type_of_change":"1","version":"HPD9","vib_list":[{"name":"CP048369","version":"HPD9.2-7.0.0.15843807"}]}],"id":{"product":"1bfd9c2e979e4c999fa2978061e8b412","version":"9f43d2e224554a129b092d1ce7da8507"},"installation":{"command":"CP040533.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB4000JEXYA and MB6000JEXYB Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB4000JEXYAおよびMB6000JEXYBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB4000JEXYA","target_guid":"002340a5-4d00-3442-3030-304a45585941","type":"sas"},{"id":"MB6000JEXYB","target_guid":"002340a5-4d00-3642-3030-304a45585942","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-07T20:14:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000JEXYB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB4000JEXYA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"8045282","datemodified":"2021-05-17T21:19:43","file_list":["/CP047950.vmexe","/CP047950.vmexe64","/CP047950.vmfile","/CP047950.xml","/README.txt"],"md5sum":"647a9d07aa3aa78c0e8da120cae228f7","name":"CP047950.zip","release":"2021-05-18T02:16:15","revision":"0","sha1sum":"cba2256d8303e9691eb5babacdd7258aa4a6d437","size":"7MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021","vib_list":[]}],"id":{"product":"77de034d485c4fb1942e2bf46cd3c50b","version":"fb7229be284e4c6ca11c399a933b2360"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component requires that the CRU driver be loaded before the component can run.</p>\n\n<p>The minimum CRU version for 5.5 is 5.5.4.1.<br />\nThe minimum CRU version for 6.0 is 6.0.8.<br />\nThe minimum CRU version for 6.5 is 6.5.8.<br />\nThe minimum CRU version for 6.7 is 6.7.10.<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>SPP Offline mode boots a special Linux OS environment, thus the Linux Components are used, not the VMware Components</li>\n</ul>\n\n<p><br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Download the appropriate SPP</li>\n\t<li>Add the component to the SPP</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run&nbsp; SUM</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps to complete the firmware update</li>\n\t<li>Refer to the SPP documentation for detailed instructions at:&nbsp; <a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Component ( CPxxxxxx.zip) in a temporary directory</li>\n\t<li>From the same directory, unzip the Component:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>To perform the standalone installation, execute the command:<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>Follow the directions given by the Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system for the firmware update to take effect</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、実行する前にCRUドライバーがロードされている必要があります。</p>\n\n<p>5.5の最小CRUバージョンは5.5.4.1です。<br />\n6.0の最小CRUバージョンは6.0.8です。<br />\n6.5の最小CRUバージョンは6.5.8です。<br />\n6.7の最小CRUバージョンは6.7.10です。<br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMwareコンポーネントではなく、Linuxコンポーネントが用いられます</li>\n</ul>\n\n<p><br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします</li>\n\t<li>SPPにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします</li>\n\t<li>SUMを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います</li>\n\t<li>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>コンポーネント (CPxxxxxx.zip)を一時ディレクトリに置きます</li>\n\t<li>同じディレクトリからコンポーネントをunzipします:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>スタンドアロンのインストールを行うために、次のコマンドを実行します：<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>コンポーネントの指示に従います</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n\t<li>システムを再起動し、ファームウェアのアップデートを有効にします</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware - HPE ProLiant DL580 Gen9 (U17) Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"5","minor":"5","name":"VMware vSphere 5.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-17T02:27:15","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>Ver. 2.80_10-16-2020(B) contains updates to the component packaging and is functionally equivalent to ver. 2.80_10-16-2020. It is not necessary to upgrade with Revision (B) if a previous component revision was used to upgrade the firmware to 2.80_10-16-2020.</p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000016 (CPUID 306F4) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000019 (CPUID 306F4) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"}],"sw_keys":[{"name":"U17","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6180640","datemodified":"2021-06-18T21:49:02","file_list":["./usr/lib/i386-linux-gnu/firmware-system-i38-2.90_2021_04_29-2.1","./usr/lib/i386-linux-gnu/firmware-system-i38-2.90_2021_04_29-2.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-system-i38-2.90_2021_04_29-2.1/.setup","./usr/lib/i386-linux-gnu/firmware-system-i38-2.90_2021_04_29-2.1/CP048738.xml","./usr/lib/i386-linux-gnu/firmware-system-i38-2.90_2021_04_29-2.1/I38_2.90_04_29_2021.signed.flash","./usr/lib/i386-linux-gnu/firmware-system-i38-2.90_2021_04_29-2.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-system-i38-2.90_2021_04_29-2.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP048738.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP048738.scexe"],"md5sum":"9f2e00dba9440aa276ed124ea2424d77","name":"firmware-system-i38-2.90_2021_04_29-2.1.i386.rpm","release":"2021-06-18T21:39:05","revision":"0","sha1sum":"85338d2e3da7a5c8b26ec71996bfb39413039a9b","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.90_04-29-2021"}],"id":{"product":"2cade22bb0f84fafbf250afecb7afed8","version":"05bb4fc457fe45c9b3937300d6cb9571"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HPE ProLiant Agentless Management Service (<strong>AMS</strong>) and HPE SNMP Agents (<strong>SNMP Agents</strong>) are both running.&nbsp; HPE does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager 8.0.0 or later, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p><strong>Verify the RPM signature using the following steps:</strong></p>\n\n<p>Download the HPE GPG 2048-bit Public Key (hpePublicKey2048_key1.pub), which is available from the HPE SDR web site:&nbsp;<a href=\"https://downloads.linux.hpe.com/keys.html\">https://downloads.linux.hpe.com/keys.html</a></p>\n\n<p>Import the public key while logged in as root by running the following command:</p>\n\n<p>&nbsp;&nbsp; # rpm --import /path_to_the_key/file_name_of_the_key</p>\n\n<p>&nbsp;&nbsp; example # rpm --import /path_to_the_key/26C2B797.pub</p>\n\n<p><strong>Verify the RPM:</strong></p>\n\n<p>Use the rpm --checksig command to validate and verify the digital signature of the signed file. The output from the command indicates the validity of the signature:</p>\n\n<p>&nbsp;&nbsp; # rpm --checksig filename_of_the_rpm</p>\n\n<p>&nbsp;&nbsp; example result #&nbsp; rpm --checksig &lt;filename&gt;.rpm</p>\n\n<p>&nbsp; &lt;filename&gt;.rpm: digests signatures OK</p>\n\n<p>If your file does not pass verification or you do not have the Hewlett Packard Enterprise Company public key installed, you may see an error:</p>\n\n<p>&nbsp;&nbsp; # rpm --checksig sample_file.rpm</p>\n\n<p>&nbsp;&nbsp; sample_file.rpm: (SHA1) DSA sha1 md5 (GPG) NOT OK (MISSING KEYS: key#s)</p>\n\n<p>In this case then do not install the rpm. This means the file has been modified in some way since being released from Hewlett Packard Enterprise Company.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant BL660c Gen9 (I38) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant BL660c Gen9(I38)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Oracle Linux 6 (AMD64/EMT64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Oracle Linux 7","platform":"Oracle Enterprise Linux","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-18T21:24:46","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463.  These issues are not unique to HPE servers.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.</p>\n\n<p>Ver. 2.90_04-29-2021 (B) contains support for Red Hat Enterprise Linux 8 Server.&nbsp; It is functionally equivalent to ver. 2.90_04-29-2021.&nbsp; It is not necessary to upgrade with version 2.90_04-29-2021 (B) if a previous component revision was used to upgrade the firmware to ver. 2.90_04-29-2021.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for the Intel technical sighting referred to as MD Clear. The Intel microcode patches included in this release are version 0x00000046 (CPUID 306F2) and 0x0B00003E (CPUID 406F1). This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-12360 and CVE-2020-12357. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00463. These issues are not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"}],"sw_keys":[{"name":"I38","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000300JWSJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEn0HPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57534a50","Version":"HPD4"},{"DeviceName":"EG000600JWJNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEn0HPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e48","Version":"HPD4"},{"DeviceName":"EG001200JWJNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEn0HPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e4b","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: EG000300JWSJP, EG000600JWJNH and EG001200JWJNK"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: EG000300JWSJP、EG000600JWJNHおよびEG001200JWJNK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"3003592","datemodified":"2021-07-26T19:40:37","file_list":["cp049143.xml","cpqsetup.exe","payload.json","setup.dll","TA15SEn0HPD4.REL"],"md5sum":"493b090f05912a5683e911f7d94faf08","name":"cp049143.exe","release":"2021-07-26T19:33:06","revision":"0","sha1sum":"5c762bdddade13d2b8f3d12e071f443473a20706","size":"2MB","target_guids":["452340a5-3047-3030-3330-304a57534a50","452340a5-3047-3030-3630-304a574a4e48","452340a5-3047-3130-3230-304a574a4e4b"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"d09d3bc174174ab69b229c1370a5ce48","version":"c6413c9a2e724941a0d228bd68457da3"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EG000300JWSJP、EG000600JWJNHおよびEG001200JWJNKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG001200JWJNK","target_guid":"452340a5-3047-3130-3230-304a574a4e4b","type":"sas"},{"id":"EG000600JWJNH","target_guid":"452340a5-3047-3030-3630-304a574a4e48","type":"sas"},{"id":"EG000300JWSJP","target_guid":"452340a5-3047-3030-3330-304a57534a50","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T19:25:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001200JWJNK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG000600JWJNH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG000300JWSJP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component contains version 9.4.5.20 of the QLogic Storport driver which provides Fibre Channel-Host Bus Adapter driver support for HPE storage arrays. "}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1617600","datemodified":"2021-08-27T03:45:14","file_list":["cp048729.xml","cpqsetup.exe","install.xml","ql2300.cat","ql2300.sys","ql2x00.inf","QLOGIC","qlsrvc.exe","QlStorInstaller.dll","readme.txt","release.txt","SysConfig.frm","SysConfig.frm.ja","txtsetup.oem"],"md5sum":"fc717db19221ac26edc6affc7fd4ec03","name":"cp048729.exe","release":"2021-08-27T03:41:59","revision":"0","sha1sum":"e639ff1bffc73a8c665e495665e31d1fd964cd82","size":"1MB","target_guids":[],"type_of_change":"1","version":"9.4.5.20"}],"id":{"product":"49d5e44e5b7f4fe6b4c17e09f2d5708a","version":"012f44ff069f4533ac9f01b81eccae75"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br />\n<br />\nFrom that drive and directory, execute the downloaded file.<br />\n<br />\nClick the &quot;Install&quot; button to proceed with the installation.<br />\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Fibre Channel Adapter Kit for the x64 QLogic Storport Driver for Microsoft Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015D","subven":"1077","target_guid":"","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015C","subven":"1077","target_guid":"","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-18T06:47:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Made improvements to the Fabric Port Identification Number (FPIN) and Universal Storage Area Network (SAN) Congestion Mitigation (USCM) Congestion Management algorithms.</li>\n</ul>\n\n<p>Updated&nbsp;to&nbsp;version 9.4.5.20</p>\n","curr_fixes_x_late":"<ul>\n\t<li>Removed the &quot;fwload&quot; registry parameter.</li>\n\t<li>Fixed an unwanted behavior where Link up/down messages were not always logged in the Window System Event log.</li>\n\t<li>Fixed unwanted behavior with the reporting of Fabric Port Identification Number (FPIN) and Universal Storage Area Network (SAN) Congestion Mitigation (USCM) statistics.</li>\n\t<li>Fixed an unwanted behavior where connections to tape drives may fail to recover in the event of &quot;SCSI Check Condition&quot; commands or cable pulls.</li>\n\t<li>Fixed an unwanted behavior where the server may encounter a Blue Screen Of Death (BSOD) 0x0000009f message during shutdown as described in <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00116202en_us\">Advisory: HPE Host Bus Adapters - HPE Platforms Running a Microsoft Windows Server 2016 / 2019 Hyper-V Environment, and Configured With Certain HPE HBAs With the QLogic Storport Driver v9.4.2.20, May Experience a Bug Check 0x9F Event</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"ql2300.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EK0800JVYPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304b-3830-304a5659504e","Version":"HPD7"},{"DeviceName":"EO1600JVYPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-314f-3630-304a56595050","Version":"HPD7"},{"DeviceName":"MK0800JVYPQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304b-3830-304a56595051","Version":"HPD7"},{"DeviceName":"MO1600JVYPR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304a56595052","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EK0800JVYPN, EO1600JVYPP, MK0800JVYPQ and MO1600JVYPR Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EK0800JVYPN、EO1600JVYPP、MK0800JVYPQ、およびMO1600JVYPRドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- EK0800JVYPN, EO1600JVYPP, MK0800JVYPQ and MO1600JVYPR Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD7</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD7 that results in SSD failure at 40,000 hours of operation (i.e., 4 years, 205 days 16 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us</a>.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5195534","datemodified":"2021-07-23T09:20:00","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-481c8ea9a7-HPD7-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-481c8ea9a7-HPD7-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-481c8ea9a7-HPD7-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-481c8ea9a7-HPD7-4.1/CP048202.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-481c8ea9a7-HPD7-4.1/PLTGIID7.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-481c8ea9a7-HPD7-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-481c8ea9a7-HPD7-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-481c8ea9a7-HPD7-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-481c8ea9a7-HPD7-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048202.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048202.scexe"],"md5sum":"3c31d6cd6ac2d3c2458936d7b122c3ff","name":"firmware-hdd-481c8ea9a7-HPD7-4.1.x86_64.rpm","release":"2021-07-23T09:08:10","revision":"0","sha1sum":"a14dc2db10c1f56e3fc95e44f1dd45bf46f8ff4f","size":"4MB","target_guids":["002340a5-4500-304b-3830-304a5659504e","002340a5-4500-314f-3630-304a56595050","002340a5-4d00-304b-3830-304a56595051","002340a5-4d00-314f-3630-304a56595052"],"type_of_change":"2","version":"HPD7"}],"id":{"product":"189399e2f82a48ee85c54d779b410263","version":"83f8a4db53984c1097dbae958adb1a17"},"installation":{"command":"CP043252.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) -  EK0800JVYPN, EO1600JVYPP, MK0800JVYPQ and MO1600JVYPR Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for Linux (x64) - EK0800JVYPN、EO1600JVYPP、MK0800JVYPQ、およびMO1600JVYPRドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MO1600JVYPR","target_guid":"002340a5-4d00-314f-3630-304a56595052","type":"sas"},{"id":"EO1600JVYPP","target_guid":"002340a5-4500-314f-3630-304a56595050","type":"sas"},{"id":"MK0800JVYPQ","target_guid":"002340a5-4d00-304b-3830-304a56595051","type":"sas"},{"id":"EK0800JVYPN","target_guid":"002340a5-4500-304b-3830-304a5659504e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T11:19:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>&nbsp;Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD7 that results in SSD failure at 40,000 hours of operation (i.e., 4 years, 205 days 16 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us</a>.</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD7 that results in SSD failure at 40,000 hours of operation (i.e., 4 years, 205 days 16 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us</a>.</li>\n</ul>","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EK0800JVYPN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO1600JVYPP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO1600JVYPR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MK0800JVYPQ","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWFVK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATdsHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a5746564b","Version":"HPD4"},{"DeviceName":"MB006000JWFVL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATdsHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a5746564c","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB004000JWFVK and MB006000JWFVL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB004000JWFVK and MB006000JWFVL&nbsp;Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3036072","datemodified":"2021-07-23T18:55:35","file_list":["cp048562.xml","cpqsetup.exe","payload.json","setup.dll","TATCATdsHPD4.REL"],"md5sum":"246fba3c6a68181f7e4d69c264afac8e","name":"cp048562.exe","release":"2021-07-23T18:48:05","revision":"0","sha1sum":"c7a999fc8d065bcf8623cdbc222ae6704f21a3a5","size":"2MB","target_guids":["4d2340a5-3042-3430-3030-304a5746564b","4d2340a5-3042-3630-3030-304a5746564c"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"e0822b357e024225a58d203426c0d686","version":"195ef2bbd73c45eb818369020e4af28f"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB004000JWFVK and MB006000JWFVL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB004000JWFVKおよびMB006000JWFVLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB004000JWFVK","target_guid":"4d2340a5-3042-3430-3030-304a5746564b","type":"sas"},{"id":"MB006000JWFVL","target_guid":"4d2340a5-3042-3630-3030-304a5746564c","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T06:55:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>There is no compelling reason to update this firmware. Risk is that whoever looks at the Vendor ID in the VPD page will notice that it refers to HP instead of HPE. There is no functional risk if not upgraded.&nbsp;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.<br />\n\t&nbsp;</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB004000JWFVK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB006000JWFVL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK003840GWSXL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M52004G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-30475753584c","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: VK003840GWSXL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK003840GWSXL Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16486555","datemodified":"2021-08-27T10:39:00","file_list":["/CP048410_BUILD_2.data","/CP048410.vmexe","/CP048410.vmexe64","/CP048410.vmfile","/CP048410_VMw.zip","/CP048410.xml","/payload.json","/CP048410_VMw.zip/index.xml","/CP048410_VMw.zip/vendor-index.xml","/CP048410_VMw.zip/metadata.zip","/CP048410_VMw.zip/vib20/CP048410/HPE_bootbank_CP048410_HPG3.2-7.0.0.15843807.vib","/CP048410_VMw.zip/metadata.zip/vendor-index.xml","/CP048410_VMw.zip/metadata.zip/vmware.xml","/CP048410_VMw.zip/metadata.zip/vibs/CP048410-145575630117397249.xml","/CP048410_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048410_HPG3.2-7.0.0.15843807.xml"],"md5sum":"a68b130f5971006a0372c8cceb555761","name":"CP048410.zip","release":"2021-08-27T10:34:09","revision":"0","sha1sum":"60b795b4d3142740242ae930401fe3b214791ca6","size":"15MB","target_guids":["562340a5-304b-3330-3834-30475753584c"],"type_of_change":"1","version":"HPG3","vib_list":[{"name":"CP048410","version":"HPG3.2-7.0.0.15843807"}]}],"id":{"product":"f2d480bbb5d747efac90df2828bbca07","version":"7eefa6e53c1949d180cc0f73930c6eda"},"installation":{"command":"CP040786.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>HP Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK003840GWSXL Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VK003840GWSXLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VK003840GWSXL","target_guid":"562340a5-304b-3330-3834-30475753584c","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T05:41:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Improved Product Quality and Reliability. Changed Cap Charge Timeout to 14 seconds from 4 seconds to provide additional time for cap charge in marginal power environment.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK003840GWSXL","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for the HPE Emulex 10/20 GbE Server Adapters for Windows Server 2016."},{"lang":"ja","x_late":"このコンポーネントパッケージは、HPE Emulex 10/20GbEサーバーアダプタードライバー for Windows Server 2016を含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"1613208","datemodified":"2020-06-12T11:05:50","file_list":["bepnic.dll","bepnic.rtf","cp044541.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll","occfg.exe","ocnd65.cat","ocnd65.inf","ocnd65.sys"],"md5sum":"15cebde2a9436105658e4a57e87db28e","name":"cp044541.exe","release":"2020-06-12T10:52:05","revision":"0","sha1sum":"2bfc995dcd8113e38aff799c73cda3d66774cee5","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfe4a13f6"],"type_of_change":"0","version":"12.0.1195.0"}],"id":{"product":"a0c7bf6781ed49d0a1fa08387a0fba69","version":"b0dcc06402cc405fa2ceff7f256a9fe3"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>\n          [インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex 10/20 GbE Driver for Windows Server 2016"},{"lang":"ja","x_late":"HPE Emulex 10/20 GbEドライバーfor Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"0728","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c220a","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c21d4","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072815908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-11T01:46:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now remove&nbsp;supports Synergy and Blade&nbsp;Server.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"}],"sw_keys":[{"name":"ocnd65.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE QLogic FastLinQ 10/25/50 Gigabit Ethernet NICs running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 8で動作するHPE QLogic FastLinQ 10/25/50 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"18034061","datemodified":"2021-08-11T14:27:03","file_list":["./etc/depmod.d/fastlinq.conf","./etc/dracut.conf.d/fastlinq.conf","./lib/firmware/qed","./lib/firmware/qed/qed_init_values_zipped-8.50.18.0.bin","./lib/modules/4.18.0-305.el8.x86_64","./lib/modules/4.18.0-305.el8.x86_64/extra","./lib/modules/4.18.0-305.el8.x86_64/extra/qlgc-fastlinq","./lib/modules/4.18.0-305.el8.x86_64/extra/qlgc-fastlinq/qed.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/qlgc-fastlinq/qede.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/qlgc-fastlinq/qedf.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/qlgc-fastlinq/qedi.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/kmod-qlgc-fastlinq/component.xml"],"md5sum":"59d9ffbf41d22e489410738a2a62ac5f","name":"kmod-qlgc-fastlinq-8.55.14.0-2.rhel8u4.x86_64.rpm","release":"2021-08-11T13:58:19","revision":"0","sha1sum":"aadf2fa42e38d9fbc568452050466c23448f932d","size":"17MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd6456294"],"type_of_change":"0","version":"8.55.14.0-2"},{"bytes":"17686886","datemodified":"2021-08-11T14:23:45","file_list":["./etc/depmod.d/fastlinq.conf","./etc/dracut.conf.d/fastlinq.conf","./lib/firmware/qed","./lib/firmware/qed/qed_init_values_zipped-8.50.18.0.bin","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/qlgc-fastlinq","./lib/modules/4.18.0-240.el8.x86_64/extra/qlgc-fastlinq/qed.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/qlgc-fastlinq/qede.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/qlgc-fastlinq/qedf.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/qlgc-fastlinq/qedi.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/kmod-qlgc-fastlinq/component.xml"],"md5sum":"cfebace483af63884e15fd394e278d9c","name":"kmod-qlgc-fastlinq-8.55.14.0-2.rhel8u3.x86_64.rpm","release":"2021-08-11T13:58:19","revision":"0","sha1sum":"c08607bdc8d7641cbfa6eac457528ddb5740491c","size":"16MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd6456294"],"type_of_change":"0","version":"8.55.14.0-2"}],"id":{"product":"fac6c21a4a1e47499a956ff93dccfbd6","version":"19dae3a2539743a5abbe9ccdbb7d9831"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>Download README for any additional installation instructions.</p>\n"},{"lang":"ja","x_late":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>\n\n<p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>\n\n<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>\n\n<p> </p>\n\n<p>その他のインストール手順についてのREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE QLogic FastLinQ 10/25/50 GbE Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"Red Hat Enterprise Linux 8用HPE QLogic FastLinQ 10/25/50 GbEドライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"8070","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021d","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021f","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0074","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770074","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0073","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770073","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-807015900220","type":"pci","ven":"1077"},{"dev":"8070","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8070159002bd","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0070","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770070","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0069","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770069","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0068","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770068","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0071","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770071","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0072","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770072","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021a","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021b","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0070","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770070","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0069","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770069","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0068","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770068","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0071","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770071","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0072","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770072","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0074","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770074","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0073","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770073","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 8 update 3 and 8 update 2</p>\n","latest_fixes_x_late":"<ul>\n\t<li>This product corrects an issue where the driver fails to load in NPAR mode when RoCE Data Center Quantized Congestion Notification (DCQCN) is enabled.</li>\n\t<li>This product corrects an issue ethernet data rate limiting unable on VFs.</li>\n\t<li>This product addresses a system crash seen when injecting a fw_assert on a NIC PF.</li>\n\t<li>This product addresses a system crash seen when limiting number of MSI-X interrupt vectors as requested for VFs</li>\n\t<li>This product addresses a system crash seen when unloading and reloading the RoCE driver only.</li>\n\t<li>This product addresses a system crash seen during multiple reboots of virtual machines using VFs and RDMA.</li>\n\t<li>This product addresses a the connection recover failed with heavy traffic</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 8 update 4</p>\n","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where the 10GbE Adapters having an DNS resolution issue on Kubernetes container-orchestration system</li>\n\t<li>This product addresses an issue where system crashes after PCIe error injection multiple times on HPE SDFlex system</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-qlgc-fastlinq","sw_key_expectedpath":"software:rpm"},{"name":"kmod-qlgc-fastlinq","sw_key_expectedpath":"software:rpm"},{"name":"kmod-qlgc-fastlinq","sw_key_expectedpath":"software:rpm"},{"name":"kmod-qlgc-fastlinq","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000GWXKK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG08acHPG3.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304757584b4b","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB016000GWXKK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB016000GWXKK Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3710568","datemodified":"2021-07-26T16:29:04","file_list":["cp049127.xml","cpqsetup.exe","payload.json","setup.dll","TAMG08acHPG3.REL"],"md5sum":"0b67804894c264bacab9ace90f5e1cbc","name":"cp049127.exe","release":"2021-07-26T16:18:04","revision":"0","sha1sum":"9d750e9fe79ed23f4e863a20ff6bad57a5bca262","size":"3MB","target_guids":["4d2340a5-3042-3631-3030-304757584b4b"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"d05a1433339f497faa2734fb31c015eb","version":"ff851755b36f45b1af25354b0b757c07"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB016000GWXKK Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB016000GWXKK","target_guid":"4d2340a5-3042-3631-3030-304757584b4b","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T16:05:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB016000GWXKK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEe0HPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e4c","Version":"HPD4"},{"DeviceName":"EG002400JWJNN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEe0HPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e4e","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: EG001800JWJNL and EG002400JWJNN"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: EG001800JWJNLおよびEG002400JWJNN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - EG001800JWJNL and EG002400JWJNN&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"3003568","datemodified":"2021-07-26T19:07:55","file_list":["cp049140.xml","cpqsetup.exe","payload.json","setup.dll","TA15SEe0HPD4.REL"],"md5sum":"e5464ca277a35c419c64edbd481bfad8","name":"cp049140.exe","release":"2021-07-26T19:00:14","revision":"0","sha1sum":"e4b69a2e8cc39dad541f983e51bf871a2b6852dc","size":"2MB","target_guids":["452340a5-3047-3130-3830-304a574a4e4c","452340a5-3047-3230-3430-304a574a4e4e"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"057a33153b064c9280dd7da9d3d5a47a","version":"6f44c200f7ed46c1b8f85d55ba37161d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG001800JWJNL and EG002400JWJNN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EG001800JWJNLおよびEG002400JWJNNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG002400JWJNN","target_guid":"452340a5-3047-3230-3430-304a574a4e4e","type":"sas"},{"id":"EG001800JWJNL","target_guid":"452340a5-3047-3130-3830-304a574a4e4c","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T18:53:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware provides a change to the Vendor ID in the VPD page that refers to HP instead of HPE.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001800JWJNL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG002400JWJNN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"VMware ESXi 6.5/6.7 Mellanox mst driver for Mellanox devices"},{"lang":"ja","x_late":"VMware ESXi 6.5/6.7 Mellanox mstドライバー for Mellanoxデバイス"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"27891","datemodified":"2021-08-27T13:28:14","file_list":["/MLNX-NMST-ESX-6.5.0-4.12.0.105.zip","/cp048358.xml","/MLNX-NMST-ESX-6.5.0-4.12.0.105.zip/index.xml","/MLNX-NMST-ESX-6.5.0-4.12.0.105.zip/vendor-index.xml","/MLNX-NMST-ESX-6.5.0-4.12.0.105.zip/metadata.zip","/MLNX-NMST-ESX-6.5.0-4.12.0.105.zip/MEL_bootbank_nmst_4.12.0.105-1OEM.650.0.0.4598673.vib","/MLNX-NMST-ESX-6.5.0-4.12.0.105.zip/metadata.zip/vendor-index.xml","/MLNX-NMST-ESX-6.5.0-4.12.0.105.zip/metadata.zip/vmware.xml","/MLNX-NMST-ESX-6.5.0-4.12.0.105.zip/metadata.zip/vibs/nmst--7851970169650426567.xml","/MLNX-NMST-ESX-6.5.0-4.12.0.105.zip/metadata.zip/bulletins/MLNX-NMST-ESX-4.12.0.105.xml"],"md5sum":"90c0354d9cc28f97a30aab5a607d267f","name":"cp048358.zip","release":"2021-08-27T13:27:29","revision":"0","sha1sum":"355a92a037243920d70f349bd40705a90b2218ab","size":"27KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec89537299"],"type_of_change":"1","version":"2020.11.11","vib_list":[{"name":"nmst","version":"4.12.0.105-1OEM.650.0.0.4598673"}]}],"id":{"product":"60580eadc28e490db38d80ac26f5a3b8","version":"eaeff398275e4675a0c6a000765f1aa7"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Remote Online:&nbsp;</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the HPE USB Key Creator Utility.&nbsp;</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux .</li>\n\t<li>cd /SPP20xxxxx and launch SUM&nbsp;(launch_sum.bat for Windows and ./launch_sum.sh for Linux).</li>\n\t<li>Select &quot;Baseline Library&quot; and wait for the Baseline inventory to complete.</li>\n\t<li>Select &quot;Nodes&quot; from the &quot;Smart Update Manager x.x.x&quot; drop down.</li>\n\t<li>Click, &quot;Add Node&quot;.\n\t<ul>\n\t\t<li>If adding a Gen9 server,\n\t\t<ul>\n\t\t\t<li>Provide IP address of the ESXi host.</li>\n\t\t\t<li>Enter&nbsp;the ESXi host credentials (root or administrator username and password)&nbsp;</li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>If adding a Gen10 and above server,\n\t\t<ul>\n\t\t\t<li>Provide iLO IP address of the ESXi host server.</li>\n\t\t\t<li>Enter the iLO credentials of the ESXi host server.</li>\n\t\t</ul>\n\t\t</li>\n\t</ul>\n\t</li>\n\t<li>Follow&nbsp;Smart Update Manager Steps and complete the driver update.&nbsp;</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware VUM or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>リモートオンライン: </strong></p>\n\n<ol>\n\t<li>HPE USB Key Creator Utilityを使用して、SPPをUSBキーにコピーします。 </li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。</li>\n\t<li>cd /SPP20xxxxx およびSUMを起動します。（Windowsの場合はlaunch_sum.bat、Linuxの場合は./launch_sum.sh）</li>\n\t<li>\"ベースラインライブラリ\"を選択し、ベースラインインベントリが完了するのを待ちます。</li>\n\t<li>\"Smart Update Manager x.x.x\"ドロップダウンから\"ノード\"を選択します。</li>\n\t<li>\"ノードの追加\"をクリックします。\n\t<ul>\n\t\t<li>Gen9サーバーを追加する場合、\n\t\t<ul>\n\t\t\t<li>ESXiホストのIPアドレスを提供します。</li>\n\t\t\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します </li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>Gen10以降のサーバーを追加する場合、\n\t\t<ul>\n\t\t\t<li>ESXiホストサーバーのiLO IPアドレスを提供します。</li>\n\t\t\t<li>ESXiホストサーバーのiLO認証情報を入力します。</li>\n\t\t</ul>\n\t\t</li>\n\t</ul>\n\t</li>\n\t<li>Smart Update Managerの指示に従い、ドライバーのアップデートを完了します。 </li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li>\n\t<li>オフラインバンドルをインストールするために、VMware VUMまたはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"net-mst kernel module driver component for VMware ESXi 6.5 and 6.7"},{"lang":"ja","x_late":"net-mstカーネルモジュールドライバーコンポーネント for VMware ESXi 6.5および6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"032D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-10171590032d","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30047","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"0221","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101315900221","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-07T09:07:19","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>NMST version&nbsp;4.12.0.105:</p>\n\n<p>&nbsp;</p>\n\n<p>This version adds support for the following adapters:</p>\n\n<ul>\n\t<li>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter&nbsp;(Part Number: P21930-B21)</li>\n\t<li>HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter (Part Number: P11341-B21)</li>\n\t<li>HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACHT Adapter (Part Number: P13188-B21)</li>\n\t<li>HPE Ethernet 10/25Gb 2-port SFP28 MCX562A-ACAI OCP3 Adapter (Part Number: P10112-B21)</li>\n\t<li>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (Part Number: P21927-B21)</li>\n\t<li>HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter (Part Number: P06154-B21)</li>\n\t<li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter (Part Number: P06250-B21)</li>\n\t<li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter (Part Number: P06251-B21)</li>\n\t<li>HPE InfiniBand HDR/Ethernet 200Gb 1-port MCX653105A-HDAT QSFP56 x16 Adapter (Part Number: P23664-B21)</li>\n\t<li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port MCX653105A-ECAT QSFP56 x16 Adapter (Part Number: P23665-B21)</li>\n\t<li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port MCX653106A-ECAT QSFP56 x16 Adapter (Part Number: P23666-B21)</li>\n\t<li>HPE Ethernet 100Gb 2-Port QSFP56 MCX623106AS-CDAT Adapter (Part Number: P25960-B21)</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>NMST version&nbsp;4.12.0.105:</p>\n\n<p>&nbsp;</p>\n\n<p>This version adds support for the following adapters:</p>\n\n<ul>\n\t<li>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter&nbsp;(Part Number: P21930-B21)</li>\n\t<li>HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter (Part Number: P11341-B21)</li>\n\t<li>HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACHT Adapter (Part Number: P13188-B21)</li>\n\t<li>HPE Ethernet 10/25Gb 2-port SFP28 MCX562A-ACAI OCP3 Adapter (Part Number: P10112-B21)</li>\n\t<li>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (Part Number: P21927-B21)</li>\n\t<li>HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter (Part Number: P06154-B21)</li>\n\t<li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter (Part Number: P06250-B21)</li>\n\t<li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter (Part Number: P06251-B21)</li>\n\t<li>HPE InfiniBand HDR/Ethernet 200Gb 1-port MCX653105A-HDAT QSFP56 x16 Adapter (Part Number: P23664-B21)</li>\n\t<li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port MCX653105A-ECAT QSFP56 x16 Adapter (Part Number: P23665-B21)</li>\n\t<li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port MCX653106A-ECAT QSFP56 x16 Adapter (Part Number: P23666-B21)</li>\n\t<li>HPE Ethernet 100Gb 2-Port QSFP56 MCX623106AS-CDAT Adapter (Part Number: P25960-B21)</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"","value":"HPE Apollo kl20 Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"","value":"HPE Apollo am35 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo pc40 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"","value":"HPE Apollo sx40 Server"}],"sw_keys":[{"name":"nmst:4.12.0.105-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This package updates the I/O module firmware on HPE D3600, D3700, D3610 and D3710 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"4038191","datemodified":"2021-06-18T07:46:29","file_list":["./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-3.1","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-3.1/CP048695.xml","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-3.1/Config.xml","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-3.1/Reveille-Release-5.04-build-000.bin","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-3.1/ccissflash","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048695.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048695.scexe"],"md5sum":"d2aa7e307d81e4631706514f58ffbea1","name":"firmware-d3000-5.04-3.1.x86_64.rpm","release":"2021-06-18T07:38:04","revision":"0","sha1sum":"24ec359955d35cf23fefbe533cc2bf51767bd036","size":"3MB","target_guids":[],"type_of_change":"1","version":"5.04"}],"id":{"product":"03d844af81f5467cb38bba8a992eb6c1","version":"82a3e0814fc446acab526462fc2c2c5b"},"installation":{"command":"setup","command_params":"-t D3600 -t D3610 -t D3700 -t D3710 -v 5.04 -i Reveille-Release-5.04-build-000.bin -l D3000.log","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":900,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Linux Smart Component Installation Instructions:</strong></p>\n\n<p><strong>Updating firmware with rpm installation:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;. </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The&nbsp;CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-d3000-&lt;version&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:&nbsp;</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-d3000-&lt;version&gt;-*&#39; location</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p><strong>NOTES:</strong></p>\n\n<p style=\"text-align:justify\">OPTIONS for in band enclosure flash</p>\n\n<table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:650px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>-d, --discover &lt;absolute path to file&gt;</td>\n\t\t\t<td>Dumps discovery information in XML format to &lt;file&gt;</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-e, --reflash</td>\n\t\t\t<td>Flash even if the device is already up to date</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-f, &nbsp;--force</td>\n\t\t\t<td>Always flash applicable devices (same as -e -g)</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-g, --downgrade</td>\n\t\t\t<td>Flash if the device has a later firmware</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-s, --silent</td>\n\t\t\t<td>Do not display any text and no user interaction required</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li>\n\t<li>Place the SPP on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\" style=\"color: blue; text-decoration: none;\"><u>USB Key Creator Utility</u></a>.</li>\n\t<li>Boot from the newly created &nbsp;Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root (You must be root in order to apply the ROM update).</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li>\n\t<li>Run the launch_sum.sh in the root of the ISO.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n\n<p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v177052/D3000_P07231-006.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE D3600/D3700/D3610/D3710 12Gb SAS Disk Enclosure ROM Flash Component for Linux (x64)"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"id":"D3600","target_guid":"","type":"sas"},{"id":"D3700","target_guid":"","type":"sas"},{"id":"D3610","target_guid":"","type":"sas"},{"id":"D3710","target_guid":"","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-17T12:49:19","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Added support of Rhel 7.8&nbsp;</p>\n\t</li>\n\t<li>\n\t<p>Added support of Rhel 8.2&nbsp;</p>\n\t</li>\n\t<li>\n\t<p>Added support of SLES15 SP2</p>\n\t</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p>\n\n<ul>\n\t<li>\n\t<p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p>\n\t</li>\n\t<li>\n\t<p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p>\n\t</li>\n\t<li>\n\t<p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p>\n\t</li>\n\t<li>\n\t<p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p>\n\t</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v177052/D3000_P07231-006.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"}],"sw_keys":[{"name":"D3710","sw_key_expectedpath":"firmware:sd:disk_enclosure"},{"name":"D3610","sw_key_expectedpath":"firmware:sd:disk_enclosure"},{"name":"D3600","sw_key_expectedpath":"firmware:sd:disk_enclosure"},{"name":"D3700","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Emulex 10/20 GbE Server Adapters running under VMware vSphere 6.5."},{"lang":"ja","x_late":"この製品には、VMware vSphere 6.5で動作するHPE Emulex 10/20GbEサーバーアダプター用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;12.0.1216.4.</p>\n"},{"lang":"ja","x_late":"<p>この製品には、ドライバーバージョン12.0.1216.4が含まれています。</p>\n"}],"files":[{"bytes":"359625","datemodified":"2020-06-11T04:20:11","file_list":["/cp044545.xml","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/elxnet-12.0.1216.4-1OEM.650.0.0.4598673.x86_64.vib","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/doc/README.txt","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/doc/release_note_elxnet_12.0.1216.4-1OEM.650.0.0.4598673.txt","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/index.xml","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/vendor-index.xml","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/metadata.zip","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/vib20/elxnet/EMU_bootbank_elxnet_12.0.1216.4-1OEM.650.0.0.4598673.vib","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/metadata.zip/vmware.xml","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-elxnet-12.0.1216.4.xml","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/metadata.zip/vibs/elxnet--643300737.xml"],"md5sum":"73a836ddc98f3eb98525843514c008a6","name":"cp044545.zip","release":"2020-06-11T04:19:09","revision":"0","sha1sum":"bf360b6dd6202191a5a4acf53d1b0e689415ee3f","size":"351KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecbc5a6557"],"type_of_change":"0","version":"2020.09.14","vib_list":[{"name":"elxnet","version":"12.0.1216.4-1OEM.650.0.0.4598673"}]}],"id":{"product":"8c5c6a0f19974bc4868c84a832f1b780","version":"d1989fededf14742a3977e71fe62ea9e"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバーにUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex 10/20 GbE Driver for VMware vSphere 6.5"},{"lang":"ja","x_late":"HPE Emulex 10/20 GbEドライバー for VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-11T01:46:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue vmnic flapping caused the network connectivity to be affected.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"elxnet:12.0.1216.4-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for HPE QLogic NX2 10/20 GbE Multifunction Adapters running under VMware vSphere 6.5."},{"lang":"ja","x_late":"この製品は、VMware vSphere 6.5上で動作するHPE QLogic NX2 10/20 GbEマルチファンクションアダプターのためのドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains the following drivers:</p>\n\n<ul>\n\t<li>qfle3, version 1.1.17.0</li>\n\t<li>qcnic, version 1.0.59.0</li>\n\t<li>qfle3i, version 1.1.5.0</li>\n\t<li>qfle3f, version 1.1.25.0</li>\n</ul>\n"}],"files":[{"bytes":"1400664","datemodified":"2021-08-11T14:00:34","file_list":["/cp047871.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/metadata.zip","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/vib20/qfle3i/QLC_bootbank_qfle3i_1.1.5.0-1OEM.650.0.0.4598673.vib","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/vib20/qfle3f/QLC_bootbank_qfle3f_1.1.25.0-1OEM.650.0.0.4598673.vib","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/vib20/qcnic/QLC_bootbank_qcnic_1.0.59.0-1OEM.650.0.0.4598673.vib","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/vib20/qfle3/QLC_bootbank_qfle3_1.1.17.0-1OEM.650.0.0.4598673.vib","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/metadata.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/metadata.zip/vmware.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/metadata.zip/vibs/qcnic-478720060.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/metadata.zip/vibs/qfle3f-1875916866.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/metadata.zip/vibs/qfle3i--1959034772.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/metadata.zip/vibs/qfle3-876788810.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-qfle3-1.1.17.0.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-qcnic-1.0.59.0.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-qfle3f-1.1.25.0.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-qfle3i-1.1.5.0.xml"],"md5sum":"836aaaed4f51a8ee4436430a005c4038","name":"cp047871.zip","release":"2021-08-11T13:57:15","revision":"0","sha1sum":"15306f031b3601fec47593aeab53d5e94c9d1819","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","20a6e8e4-bf33-4c71-a6bf-d9ecbba24fc7","20a6e8e4-bf33-4c71-a6bf-d9ec7339bbbe","20a6e8e4-bf33-4c71-a6bf-d9eca261a1a0"],"type_of_change":"0","version":"2021.09.04","vib_list":[{"name":"qfle3","version":"1.1.17.0-1OEM.650.0.0.4598673"},{"name":"qcnic","version":"1.0.59.0-1OEM.650.0.0.4598673"},{"name":"qfle3f","version":"1.1.25.0-1OEM.650.0.0.4598673"},{"name":"qfle3i","version":"1.1.5.0-1OEM.650.0.0.4598673"}]}],"id":{"product":"5cd2c31f18d541c09e937a83715365ee","version":"ea4d94a465f64c618340616c238eef26"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic NX2 10/20 GbE Multifunction Driver for VMware vSphere 6.5"},{"lang":"ja","x_late":"VMware vSphere 6.5用HPE QLogic NX2 10/20 GbEマルチファンクションドライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"16AD","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16ad159000ec","type":"pci","ven":"1077"},{"dev":"168E","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c339d","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c18d3","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c193a","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1930","type":"pci","ven":"14E4"},{"dev":"16A1","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a1159000ec","type":"pci","ven":"1077"},{"dev":"16A4","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a4159000ec","type":"pci","ven":"1077"},{"dev":"168E","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-168e15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1931","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c339d","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c18d3","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c193a","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1930","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1931","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c339d","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c193a","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1930","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1931","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16af15908148","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ae15908148","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an incorrect MTU value displayed by the ESXCLI tool.</p>\n"},{"curr_enhancements_x_late":"<p>This products enhances the mechanism that collation of data log.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"qfle3:1.1.17.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qcnic:1.0.59.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qfle3i:1.1.5.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qfle3f:1.1.25.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JWAYK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHsseFD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a5741594b","Version":"HPD6"},{"DeviceName":"MB008000JWAYH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHsseFD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57415948","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB010000JWAYK and MB008000JWAYH"},{"lang":"ja","x_late":"このSmartコンポーネントが、ファームウェアを提供できるドライブモデル： MB010000JWAYKおよびMB008000JWAYH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB010000JWAYK and MB008000JWAYH Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"18601443","datemodified":"2021-08-26T12:47:37","file_list":["/CP048334_BUILD_2.data","/CP048334.vmexe","/CP048334.vmexe64","/CP048334.vmfile","/CP048334_VMw.zip","/CP048334.xml","/payload.json","/CP048334_VMw.zip/index.xml","/CP048334_VMw.zip/vendor-index.xml","/CP048334_VMw.zip/metadata.zip","/CP048334_VMw.zip/vib20/CP048334/HPE_bootbank_CP048334_HPD6.2-7.0.0.15843807.vib","/CP048334_VMw.zip/metadata.zip/vendor-index.xml","/CP048334_VMw.zip/metadata.zip/vmware.xml","/CP048334_VMw.zip/metadata.zip/vibs/CP048334-5781854618042290416.xml","/CP048334_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048334_HPD6.2-7.0.0.15843807.xml"],"md5sum":"6b452ad211cb63153a35a062a581697a","name":"CP048334.zip","release":"2021-08-26T12:42:10","revision":"0","sha1sum":"c8b40ab61dbad03e50e69bc5261b1aa5856f31d2","size":"17MB","target_guids":["4d2340a5-3042-3031-3030-304a5741594b","4d2340a5-3042-3830-3030-304a57415948"],"type_of_change":"1","version":"HPD6","vib_list":[{"name":"CP048334","version":"HPD6.2-7.0.0.15843807"}]}],"id":{"product":"58002f5fbb3c4bdca0598c03bb921813","version":"c86b80c8d73b4e7cbfcdeff981153ae7"},"installation":{"command":"CP040637.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB010000JWAYK and MB008000JWAYH Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB010000JWAYKおよびMB008000JWAYHドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB010000JWAYK","target_guid":"4d2340a5-3042-3031-3030-304a5741594b","type":"sas"},{"id":"MB008000JWAYH","target_guid":"4d2340a5-3042-3830-3030-304a57415948","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-05T19:44:39","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000JWAYH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB010000JWAYK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GWXFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757584646","Version":"HPG2"},{"DeviceName":"MK000960GWXFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757584648","Version":"HPG2"},{"DeviceName":"MK001920GWXFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475758464b","Version":"HPG2"},{"DeviceName":"MK003840GWXFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475758464c","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL"},{"lang":"ja","x_late":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MK000480GWXFF、MK000960GWXFH、MK001920GWXFK、およびMK003840GWXFL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG1</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG1<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>This&nbsp;FW release deploys an Enhanced Media Scan algorithm that addresses an issue when the host system does not provide enough idle time for drive&rsquo;s Foreground Media Scan to be activated, which is needed to ensure long term drive reliability. It also addresses few minor issues.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"7426344","datemodified":"2021-08-17T11:17:47","file_list":["cp049300.xml","cpqsetup.exe","K503HPG2.rel","payload.json","setup.dll"],"md5sum":"b2c85349569ce17a991baff3fcd127b6","name":"cp049300.exe","release":"2021-08-17T11:10:12","revision":"0","sha1sum":"1c9369015612b4ac9b98c5795e982164838af7bc","size":"7MB","target_guids":["4d2340a5-304b-3030-3438-304757584646","4d2340a5-304b-3030-3936-304757584648","4d2340a5-304b-3130-3932-30475758464b","4d2340a5-304b-3330-3834-30475758464c"],"type_of_change":"1","version":"HPG2"}],"id":{"product":"8ebc8805a4344ec4a24a5c7109c6e07f","version":"4496af98da914abeac467b93da88b675"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for Windows(x64)- MK000480GWXFF、 MK000960GWXFH、MK001920GWXFKおよびMK003840GWXFLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MK003840GWXFL","target_guid":"4d2340a5-304b-3330-3834-30475758464c","type":"sata"},{"id":"MK001920GWXFK","target_guid":"4d2340a5-304b-3130-3932-30475758464b","type":"sata"},{"id":"MK000960GWXFH","target_guid":"4d2340a5-304b-3030-3936-304757584648","type":"sata"},{"id":"MK000480GWXFF","target_guid":"4d2340a5-304b-3030-3438-304757584646","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-17T10:49:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li> Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"<p>This&nbsp;FW release deploys an Enhanced Media Scan algorithm that addresses an issue when the host system does not provide enough idle time for drive&rsquo;s Foreground Media Scan to be activated, which is needed to ensure long term drive reliability. It also addresses few minor issues.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK001920GWXFK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWXFH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK003840GWXFL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWXFF","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXn0HPD7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57485050","Version":"HPD7"},{"DeviceName":"EH000600JWHPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXn0HPD7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5748504e","Version":"HPD7"},{"DeviceName":"EH000300JWHPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXn0HPD7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5748504c","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EH000900JWHPP, EH000600JWHPN and EH000300JWHPL"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EH000900JWHPP、EH000600JWHPN および EH000300JWHPL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4858372","datemodified":"2021-07-26T18:20:20","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD7-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD7-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD7-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD7-2.1/CP049137.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD7-2.1/TA14SXn0HPD7.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD7-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD7-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD7-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD7-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049137.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049137.scexe"],"md5sum":"0d09024de23d1cda500736d939e63a87","name":"firmware-hdd-8d68452816-HPD7-2.1.x86_64.rpm","release":"2021-07-26T18:07:04","revision":"0","sha1sum":"7d7717d64db5c4d3725420259aa6e0874f7ed7dd","size":"4MB","target_guids":["452340a5-3048-3030-3930-304a57485050","452340a5-3048-3030-3630-304a5748504e","452340a5-3048-3030-3330-304a5748504c"],"type_of_change":"1","version":"HPD7"}],"id":{"product":"6f10e85c0a8e4d0f99dcb8584f535fd3","version":"7f6005e31aa240b688679bd7c5e9b51d"},"installation":{"command":"CP041672.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux(x64) - EH000900JWHPP、EH000600JWHPNおよびEH000300JWHPLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EH000300JWHPL","target_guid":"452340a5-3048-3030-3330-304a5748504c","type":"sas"},{"id":"EH000600JWHPN","target_guid":"452340a5-3048-3030-3630-304a5748504e","type":"sas"},{"id":"EH000900JWHPP","target_guid":"452340a5-3048-3030-3930-304a57485050","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T18:03:30","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH000900JWHPP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000300JWHPL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000600JWHPN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}}]}